{"id":1967,"date":"2025-12-04T13:54:32","date_gmt":"2025-12-04T13:54:32","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1967"},"modified":"2025-12-04T15:07:56","modified_gmt":"2025-12-04T15:07:56","slug":"switchgear-component-manufacturer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/ar\/switchgear-component-manufacturer\/","title":{"rendered":"\u0645\u0635\u0646\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629"},"content":{"rendered":"<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-3a5b1c3\" data-block-id=\"3a5b1c3\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-3a5b1c3-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-155ceae\" data-v=\"4\" data-block-id=\"155ceae\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-155ceae-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-155ceae-inner-blocks\">\n<style>\n    \/* --- XBRELE PRO STYLE SYSTEM (v5.1 - Component Edition) --- *\/\n    \n    .xbrele-pro-page {\n        font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        color: #111;\n        line-height: 1.7; \n        font-size: 18px; \n        font-weight: 400;\n        background-color: #fff;\n    }\n\n    .xbrele-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        padding: 0 20px;\n    }\n\n    .xbrele-section {\n        padding: 60px 0;\n        border-bottom: 1px solid #f0f0f0;\n    }\n    .xbrele-section.bg-light {\n        background-color: #f8fbfb;\n    }\n\n    .xbrele-pro-page h1 {\n        font-size: 42px;\n        font-weight: 800;\n        text-align: center;\n        margin-bottom: 30px;\n        color: #000;\n        letter-spacing: -0.5px;\n    }\n    \n    .xbrele-pro-page h2 {\n        font-size: 30px;\n        color: #000;\n        margin-top: 50px;\n        margin-bottom: 25px;\n        position: relative;\n        padding-left: 20px;\n        border-left: 8px solid #009688; \/* XBRELE Teal *\/\n        font-weight: 700;\n        text-transform: uppercase;\n    }\n    \n    .xbrele-pro-page h3 {\n        font-size: 22px;\n        font-weight: 700;\n        margin-top: 35px;\n        margin-bottom: 15px;\n        color: #009688;\n    }\n\n    .xbrele-pro-page p {\n        margin-bottom: 25px;\n        color: #222;\n        text-align: justify;\n    }\n\n    \/* Hero \u56fe\u7247\u6837\u5f0f *\/\n    .xbrele-hero-img {\n        width: 100%;\n        height: auto;\n        border-radius: 6px;\n        margin-bottom: 40px;\n        box-shadow: 0 4px 12px rgba(0,0,0,0.1);\n        display: block;\n    }\n\n    .xbrele-list {\n        list-style: none;\n        padding: 0;\n        margin-bottom: 30px;\n    }\n    .xbrele-list li {\n        position: relative;\n        padding-left: 30px;\n        margin-bottom: 12px;\n        color: #222;\n    }\n    .xbrele-list li::before {\n        content: \"\u25a0\";\n        position: absolute;\n        left: 0;\n        color: #009688;\n        font-size: 14px;\n        top: 6px;\n    }\n\n    .xbrele-tech-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 40px 0;\n        box-shadow: 0 5px 15px rgba(0,0,0,0.05);\n        font-size: 16px;\n    }\n    .xbrele-tech-table th, .xbrele-tech-table td {\n        padding: 18px;\n        border: 1px solid #ddd;\n    }\n    .xbrele-tech-table th {\n        background-color: #009688;\n        color: #fff;\n        font-weight: 700;\n        text-align: left;\n    }\n    .xbrele-tech-table tr:nth-child(even) {\n        background-color: #fcfcfc;\n    }\n\n    .xbrele-link {\n        color: #009688;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid rgba(0,150,136,0.2);\n        transition: all 0.2s;\n    }\n    .xbrele-link:hover {\n        background-color: rgba(0,150,136,0.1);\n        border-bottom-color: #009688;\n    }\n\n    .xbrele-ext-link {\n        color: #555;\n        text-decoration: underline;\n        font-style: italic;\n    }\n\n    .xbrele-cta-box {\n        background: linear-gradient(135deg, #009688 0%, #004d40 100%);\n        color: #fff;\n        padding: 60px;\n        border-radius: 8px;\n        text-align: center;\n        margin-top: 60px;\n    }\n    .xbrele-cta-btn {\n        display: inline-block;\n        background-color: #fff;\n        color: #009688 !important;\n        padding: 18px 45px;\n        font-weight: 800;\n        text-transform: uppercase;\n        border-radius: 4px;\n        text-decoration: none;\n        margin-top: 25px;\n        font-size: 18px;\n        box-shadow: 0 4px 6px rgba(0,0,0,0.2);\n    }\n    .xbrele-cta-btn:hover {\n        background-color: #f4f4f4;\n        transform: translateY(-2px);\n    }\n<\/style>\n\n<div class=\"xbrele-pro-page\">\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h1>\u0645\u0635\u0646\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u062d\u0644\u0648\u0644 OEM<\/h1>\n            \n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/switchgear-component-manufacturing-factory.webp\" \n                 alt=\"\u0645\u0635\u0646\u0639 XBRELE \u0644\u062a\u0635\u0646\u064a\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0635\u0646\u0627\u062f\u064a\u0642 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0648\u0627\u0644\u0639\u0648\u0627\u0632\u0644\" \n                 class=\"xbrele-hero-img\" \/>\n\n            <p>\n                \u062a\u0635\u0646\u064a\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0647\u0648 \u0627\u0644\u0635\u0646\u0627\u0639\u0629 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u062f\u0639\u0645 \u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 (MV) \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (HV). \u0648\u0647\u0648 \u064a\u0646\u0637\u0648\u064a \u0639\u0644\u0649 \u0627\u0644\u0647\u0646\u062f\u0633\u0629 \u0627\u0644\u062f\u0642\u064a\u0642\u0629 \u0644\u0644\u0623\u062c\u0632\u0627\u0621 \u201c\u0627\u0644\u0633\u0644\u0628\u064a\u0629\u201d \u0627\u0644\u062d\u064a\u0648\u064a\u0629 \u2014 \u0645\u062b\u0644 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a \u0648\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0648\u0627\u0644\u0623\u0642\u0641\u0627\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u2014 \u0627\u0644\u062a\u064a \u062a\u0636\u0645\u0646 \u0633\u0644\u0627\u0645\u0629 \u0648\u0648\u0638\u0627\u0626\u0641 KYN28 \u0648 XGN \u0648\u0648\u062d\u062f\u0627\u062a Ring Main Units (RMU). \u0628\u0627\u0639\u062a\u0628\u0627\u0631\u0647\u0627 \u0634\u0631\u0643\u0629 \u0645\u062a\u062e\u0635\u0635\u0629 <strong>\u0645\u0635\u0646\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/strong>, \u060c \u062a\u0639\u0645\u0644 XBRELE \u0643\u0639\u0645\u0648\u062f \u0641\u0642\u0631\u064a \u063a\u064a\u0631 \u0645\u0631\u0626\u064a \u0644\u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0641\u064a \u062c\u0645\u064a\u0639 \u0623\u0646\u062d\u0627\u0621 \u0627\u0644\u0639\u0627\u0644\u0645. \u0645\u0646 \u0635\u0646\u0627\u062f\u064a\u0642 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0625\u0644\u0649 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0627\u0644\u062c\u062f\u0627\u0631\u064a\u0629 40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c \u0646\u062d\u0646 \u0646\u0648\u0641\u0631 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0633\u0645\u062d \u0644\u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0628\u062a\u062c\u0645\u064a\u0639 \u0645\u0639\u062f\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0648\u062b\u0648\u0642\u0629 \u0648\u0645\u062a\u0648\u0627\u0641\u0642\u0629 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 IEC \u0628\u0643\u0641\u0627\u0621\u0629 \u0648\u062b\u0642\u0629.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0639\u0645\u0644\u064a\u0629 \u062a\u0635\u0646\u064a\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/h2>\n            <p>\n                \u062a\u062a\u0646\u0648\u0639 \u0639\u0645\u0644\u064a\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u0645\u0645\u0627 \u064a\u062a\u0637\u0644\u0628 \u062e\u0628\u0631\u0629 \u0641\u064a \u0643\u0644 \u0645\u0646 \u0643\u064a\u0645\u064a\u0627\u0621 \u0627\u0644\u0628\u0648\u0644\u064a\u0645\u0631\u0627\u062a \u0648\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u0627\u062f\u0646. \u0641\u064a XBRELE\u060c \u064a\u062a\u0645 \u062a\u0642\u0633\u064a\u0645 \u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c \u0644\u062f\u064a\u0646\u0627 \u0644\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0647\u0630\u0647 \u0627\u0644\u062a\u062e\u0635\u0635\u0627\u062a \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0645\u0639 \u0636\u0645\u0627\u0646 \u0627\u0644\u062a\u0643\u0627\u0645\u0644 \u0627\u0644\u0633\u0644\u0633 \u0641\u064a \u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0646\u0647\u0627\u0626\u064a.\n            <\/p>\n            <p>\n                <strong>\u0642\u0648\u0644\u0628\u0629 \u0627\u0644\u0639\u0632\u0644 (\u0639\u0645\u0644\u064a\u0629 APG):<\/strong> \u0644\u0640 <a href=\"https:\/\/xbrele.com\/ar\/switchgear-parts\/contact-box\/\" class=\"xbrele-link\">\u0635\u0646\u0627\u062f\u064a\u0642 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 (\u0627\u0644\u0641\u0648\u0647\u0627\u062a)<\/a> \u0648\u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0627\u0644\u062c\u062f\u0627\u0631\u064a\u0629\u060c \u0646\u0633\u062a\u062e\u062f\u0645 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u062c\u0644\u0637 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0644\u0644\u0636\u063a\u0637 (APG). \u064a\u062a\u0636\u0645\u0646 \u0630\u0644\u0643 \u062e\u0644\u0637 \u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a \u0645\u0633\u0628\u0642\u064b\u0627 \u0645\u0639 \u0645\u0642\u0648\u064a\u0627\u062a \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0627 \u062a\u062d\u062a \u062a\u0641\u0631\u064a\u063a \u0647\u0648\u0627\u0626\u064a \u0644\u0625\u0632\u0627\u0644\u0629 \u0641\u0642\u0627\u0639\u0627\u062a \u0627\u0644\u0647\u0648\u0627\u0621\u060c \u062b\u0645 \u062d\u0642\u0646 \u0627\u0644\u062e\u0644\u064a\u0637 \u0641\u064a \u0642\u0648\u0627\u0644\u0628 \u0641\u0648\u0644\u0627\u0630\u064a\u0629 \u0633\u0627\u062e\u0646\u0629. \u062a\u0636\u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u062f\u0642\u0629 \u0623\u0628\u0639\u0627\u062f \u0639\u0627\u0644\u064a\u0629 \u0648\u0642\u0648\u0629 \u0639\u0627\u0632\u0644\u0629 \u0641\u0627\u0626\u0642\u0629\u060c \u0648\u0647\u064a \u0639\u0648\u0627\u0645\u0644 \u0623\u0633\u0627\u0633\u064a\u0629 \u0644\u0645\u0646\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a.\n            <\/p>\n            <p>\n                <strong>\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u0627\u062f\u0646 \u0648\u062a\u0634\u063a\u064a\u0644\u0647\u0627:<\/strong> \u0645\u0643\u0648\u0646\u0627\u062a \u0645\u062b\u0644 <a href=\"https:\/\/xbrele.com\/ar\/switchgear-parts\/earthing-switch\/\" class=\"xbrele-link\">\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 JN15<\/a> \u0648\u062a\u062a\u0637\u0644\u0628 \u0634\u0627\u062d\u0646\u0627\u062a VCB Chassis \u0647\u064a\u0627\u0643\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u062a\u064a\u0646\u0629. \u0646\u0642\u0648\u0645 \u0628\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0639\u0627\u0644\u064a \u0627\u0644\u0642\u0648\u0629 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0622\u0644\u0627\u062a \u0627\u0644\u062a\u062b\u0642\u064a\u0628 \u0648\u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621 CNC \u0644\u0625\u0646\u0634\u0627\u0621 \u0625\u0637\u0627\u0631\u0627\u062a \u064a\u0645\u0643\u0646\u0647\u0627 \u062a\u062d\u0645\u0644 \u0627\u0644\u0642\u0648\u0649 \u0627\u0644\u0643\u0647\u0631\u0648\u062f\u064a\u0646\u0627\u0645\u064a\u0643\u064a\u0629 \u0644\u0644\u0642\u0635\u064a\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 (\u062d\u062a\u0649 40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631). \u064a\u062a\u0645 \u0637\u0644\u0627\u0621 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0646\u062d\u0627\u0633\u064a\u0629 \u0628\u0627\u0644\u0641\u0636\u0629 \u0644\u0636\u0645\u0627\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0645\u0646\u062e\u0641\u0636\u0629.\n            <\/p>\n            <p>\n                <strong>\u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0648\u0627\u0644\u062a\u0643\u0627\u0645\u0644:<\/strong> \u062a\u062a\u0636\u0645\u0646 \u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u062a\u062c\u0645\u064a\u0639 \u0622\u0644\u064a\u0627\u062a \u0645\u062a\u0639\u062f\u062f\u0629 \u0627\u0644\u0623\u062c\u0632\u0627\u0621\u060c \u0645\u062b\u0644 <a href=\"https:\/\/xbrele.com\/ar\/switchgear-parts\/switchgear-components\/\" class=\"xbrele-link\">\u0623\u0642\u0641\u0627\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u062e\u0645\u0627\u0633\u064a\u0629 \u0627\u0644\u0648\u0642\u0627\u064a\u0629<\/a>. \u064a\u0642\u0648\u0645 \u0627\u0644\u0641\u0646\u064a\u0648\u0646 \u0628\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0646\u0648\u0627\u0628\u0636 \u0648\u0627\u0644\u0631\u0627\u0641\u0639\u0627\u062a \u0648\u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u0627\u062a \u0627\u0644\u0645\u0627\u0646\u0639\u0629\u060c \u0648\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0646\u0637\u0642 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0645\u0634\u063a\u0644 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0627 \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u0631\u062a\u0643\u0628 \u062e\u0637\u0623 \u062e\u0637\u064a\u0631\u064b\u0627 (\u0645\u062b\u0644 \u0625\u063a\u0644\u0627\u0642 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0639\u0644\u0649 \u0642\u0636\u064a\u0628 \u062a\u0648\u0635\u064a\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0634\u062d\u0648\u0646 \u0628\u0627\u0644\u062a\u064a\u0627\u0631).\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u062e\u0627\u0645 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0641\u064a \u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a<\/h2>\n            <p>\n                \u062a\u0628\u062f\u0623 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0644\u0648\u062d\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u062e\u0627\u0645 \u0644\u0623\u0635\u063a\u0631 \u0645\u0643\u0648\u0646\u0627\u062a\u0647\u0627. \u0644\u0627 \u062a\u0633\u062a\u062e\u062f\u0645 XBRELE \u0633\u0648\u0649 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0645\u0639\u062a\u0645\u062f\u0629 \u0644\u0636\u0645\u0627\u0646 \u0637\u0648\u0644 \u0627\u0644\u0639\u0645\u0631 \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629.\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u0646\u0638\u0627\u0645 \u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a:<\/strong> \u0646\u062d\u0646 \u0646\u0633\u062a\u062e\u062f\u0645 \u0631\u0627\u062a\u0646\u062c \u0625\u064a\u0628\u0648\u0643\u0633\u064a \u0628\u064a\u0633\u0641\u064a\u0646\u0648\u0644-\u0623 \u0639\u0627\u0644\u064a \u0627\u0644\u062c\u0648\u062f\u0629 \u0645\u062f\u0645\u062c \u0645\u0639 \u0645\u0633\u062d\u0648\u0642 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0627 \u0639\u0627\u0644\u064a \u0627\u0644\u0646\u0642\u0627\u0621. \u062a\u0648\u0641\u0631 \u0647\u0630\u0647 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0629 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0646\u062a\u0642\u0627\u0644 \u0632\u062c\u0627\u062c\u064a \u0639\u0627\u0644\u064a\u0629 (Tg &gt; 110 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629)\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0628\u0642\u0627\u0621 \u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0645\u0633\u062a\u0642\u0631\u0629 \u062d\u062a\u0649 \u0641\u064a \u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u0633\u0627\u062e\u0646\u0629.<\/li>\n                <li><strong>\u0627\u0644\u0646\u062d\u0627\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (T2):<\/strong> \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u062d\u0627\u0645\u0644\u0629 \u0644\u0644\u062a\u064a\u0627\u0631\u060c \u0645\u062b\u0644 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u062b\u0627\u0628\u062a\u0629 \u062f\u0627\u062e\u0644 \u0635\u0646\u062f\u0648\u0642 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0623\u0648 \u0634\u0641\u0631\u0627\u062a \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636\u060c \u0646\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0646\u062d\u0627\u0633 T2 (\u0628\u0646\u0642\u0627\u0648\u0629 99.9%) \u0645\u0639 \u0637\u0644\u0627\u0621 \u0641\u0636\u064a (8-12\u03bcm) \u0644\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u0645\u0648\u0635\u0644\u064a\u0629 \u0625\u0644\u0649 \u0623\u0642\u0635\u0649 \u062d\u062f.<\/li>\n                <li><strong>\u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u062f\u0644\u0641\u0646 \u0639\u0644\u0649 \u0627\u0644\u0628\u0627\u0631\u062f (SPCC):<\/strong> \u062a\u0633\u062a\u062e\u062f\u0645 \u0641\u064a \u0647\u064a\u0627\u0643\u0644 \u0627\u0644\u0634\u0627\u062d\u0646\u0627\u062a \u0648\u0622\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u062f\u0627\u062e\u0644. \u062a\u062e\u0636\u0639 \u0647\u0630\u0647 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0644\u0637\u0644\u0627\u0621 \u0628\u0627\u0644\u0632\u0646\u0643 \u0623\u0648 \u0627\u0644\u0646\u064a\u0643\u0644 \u0644\u062a\u0648\u0641\u064a\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062a\u0622\u0643\u0644\u060c \u0648\u062a\u062c\u062a\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u0631\u0634 \u0627\u0644\u0645\u0644\u062d \u0644\u0645\u062f\u0629 72 \u0633\u0627\u0639\u0629.<\/li>\n                <li><strong>\u0627\u0644\u0628\u0648\u0644\u064a \u0643\u0631\u0628\u0648\u0646\u0627\u062a (PC) \u0648\u0627\u0644\u0646\u0627\u064a\u0644\u0648\u0646:<\/strong> \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0624\u0634\u0631\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0648\u0645\u0642\u0627\u0628\u0633 \u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629\u060c \u0646\u0633\u062a\u062e\u062f\u0645 \u0645\u0648\u0627\u062f \u0628\u0644\u0627\u0633\u062a\u064a\u0643\u064a\u0629 \u062d\u0631\u0627\u0631\u064a\u0629 \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0647\u0628 (\u062f\u0631\u062c\u0629 UL94 V-0) \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0645\u0646 \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u062f\u0627\u062e\u0644 \u062d\u062c\u0631\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/h2>\n            <p>\n                \u064a\u062a\u0637\u0644\u0628 \u0625\u0646\u062a\u0627\u062c \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062a\u0646\u0648\u0639\u0629 \u0645\u0635\u0646\u0639\u064b\u0627 \u0645\u062a\u0639\u062f\u062f \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0627\u062a. \u0648\u0642\u062f \u0627\u0633\u062a\u062b\u0645\u0631\u062a XBRELE \u0641\u064a \u0622\u0644\u0627\u062a \u0645\u062a\u062e\u0635\u0635\u0629 \u0644\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u062c\u0648\u062f\u0629 \u0643\u0644 \u0645\u0646 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0639\u0627\u0632\u0644\u0629 \u0648\u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629.\n            <\/p>\n            <p>\n                <strong>\u0622\u0644\u0627\u062a \u0627\u0644\u062a\u062b\u0628\u064a\u062a APG:<\/strong> \u0648\u0631\u0634\u0629 \u0627\u0644\u0639\u0632\u0644 \u0644\u062f\u064a\u0646\u0627 \u0645\u062c\u0647\u0632\u0629 \u0628\u0622\u0644\u0627\u062a \u062a\u062b\u0628\u064a\u062a \u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a\u0629 \u0645\u0646 \u0646\u0648\u0639 APG. \u062a\u062a\u064a\u062d \u0644\u0646\u0627 \u0647\u0630\u0647 \u0627\u0644\u0622\u0644\u0627\u062a \u062a\u0634\u0643\u064a\u0644 \u0623\u0634\u0643\u0627\u0644 \u0645\u0639\u0642\u062f\u0629 \u0645\u062b\u0644 <a href=\"https:\/\/xbrele.com\/ar\/switchgear-parts\/post-insulator\/\" class=\"xbrele-link\">\u0639\u0627\u0632\u0644\u0627\u062a \u0623\u0639\u0645\u062f\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621<\/a> \u0645\u0639 \u0625\u062f\u062e\u0627\u0644\u0627\u062a \u0645\u0644\u0648\u0644\u0628\u0629 \u0645\u062f\u0645\u062c\u0629 \u0641\u064a \u062f\u0648\u0631\u0629 \u0648\u0627\u062d\u062f\u0629\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0642\u0648\u0629 \u0633\u062d\u0628 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0639\u0627\u0644\u064a\u0629.\n            <\/p>\n            <p>\n                <strong>\u062b\u0642\u0648\u0628 \u0648 \u0644\u064a\u0632\u0631 \u0628\u0631\u062c CNC:<\/strong> \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0648\u0627\u0644\u0647\u064a\u0643\u0644\u060c \u0627\u0644\u062f\u0642\u0629 \u0647\u064a \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0644\u0636\u0645\u0627\u0646 \u0633\u0644\u0627\u0633\u0629 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0627\u0644\u062a\u0641\u0643\u064a\u0643. \u062a\u0642\u0648\u0645 \u0645\u0631\u0627\u0643\u0632 CNC \u0644\u062f\u064a\u0646\u0627 \u0628\u0642\u0637\u0639 \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u0627\u0644\u0641\u0648\u0644\u0627\u0630\u064a\u0629 \u0628\u062a\u0641\u0627\u0648\u062a 0.1 \u0645\u0645\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0645\u0644\u0627\u0621\u0645\u0629 \u0643\u0644 \u0642\u0637\u0639\u0629 \u063a\u064a\u0627\u0631 \u0628\u0634\u0643\u0644 \u0645\u062b\u0627\u0644\u064a \u0644\u0644\u0648\u062d\u0629 \u062f\u0648\u0646 \u0627\u0644\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0644\u0645\u064a\u0639 \u0623\u0648 \u0627\u0644\u0637\u062d\u0646.\n            <\/p>\n            <p>\n                <strong>\u062e\u0637\u0648\u0637 \u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0623\u0633\u0637\u062d:<\/strong> \u0639\u0644\u0649 \u0627\u0644\u0631\u063a\u0645 \u0645\u0646 \u0623\u0646 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0648\u0631\u0634 \u0627\u0644\u0635\u063a\u064a\u0631\u0629 \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629\u060c \u0625\u0644\u0627 \u0623\u0646 XBRELE \u062a\u0641\u0631\u0636 \u0631\u0642\u0627\u0628\u0629 \u0635\u0627\u0631\u0645\u0629 \u0639\u0644\u0649 \u0634\u0631\u0643\u0627\u0626\u0647\u0627 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u0637\u0644\u0627\u0621 \u0628\u0627\u0644\u0641\u0636\u0629 \u0648\u0627\u0644\u0632\u0646\u0643 \u0644\u0636\u0645\u0627\u0646 \u0623\u0646 \u0627\u0644\u0633\u0645\u0627\u0643\u0629 \u0648\u0627\u0644\u0627\u0644\u062a\u0635\u0627\u0642 \u064a\u062a\u0648\u0627\u0641\u0642\u0627\u0646 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 IEC \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629 \u0627\u0644\u0631\u0637\u0628\u0629.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/h2>\n            <p>\n                \u062d\u062a\u0649 \u0639\u0627\u0632\u0644 \u0648\u0627\u062d\u062f \u0645\u0639\u064a\u0628 \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u062a\u0639\u0637\u0644 \u0643\u0627\u0645\u0644 \u0644\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0644\u0630\u0644\u0643\u060c \u062a\u0637\u0628\u0642 XBRELE \u0633\u064a\u0627\u0633\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u201c\u0635\u0641\u0631 \u0639\u064a\u0648\u0628\u201d \u0644\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u062a\u0648\u0627\u0641\u0642\u0629 \u0645\u0639 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 IEC 60694 \u0648 IEC 62271-102.\n            <\/p>\n            \n            <table class=\"xbrele-tech-table\">\n                <tr>\n                    <th>\u0627\u0633\u0645 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/th>\n                    <th>\u0627\u0644\u0645\u0643\u0648\u0646 \u0627\u0644\u0645\u0633\u062a\u0647\u062f\u0641<\/th>\n                    <th>\u0627\u0644\u063a\u0631\u0636<\/th>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0627\u0644\u0643\u0634\u0641 \u0639\u0646 \u0627\u0644\u0639\u064a\u0648\u0628 \u0628\u0627\u0644\u0623\u0634\u0639\u0629 \u0627\u0644\u0633\u064a\u0646\u064a\u0629<\/strong><\/td>\n                    <td>\u0639\u0627\u0632\u0644\u0627\u062a\u060c \u0641\u0648\u0647\u0627\u062a<\/td>\n                    <td>\u064a\u0642\u0648\u0645 \u0628\u0645\u0633\u062d \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629 \u0644\u0644\u0643\u0634\u0641 \u0639\u0646 \u0627\u0644\u0641\u0631\u0627\u063a\u0627\u062a \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629 \u0623\u0648 \u0627\u0644\u0634\u0642\u0648\u0642 \u062f\u0627\u062e\u0644 \u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u062a\u062d\u0645\u0644 \u062a\u0631\u062f\u062f \u0627\u0644\u0637\u0627\u0642\u0629<\/strong><\/td>\n                    <td>\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0639\u0632\u0644<\/td>\n                    <td>\u064a\u0637\u0628\u0642 42 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\/1 \u062f\u0642\u064a\u0642\u0629 \u0644\u0636\u0645\u0627\u0646 \u0623\u0646 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062a\u0641\u064a \u0628\u0645\u062a\u0637\u0644\u0628\u0627\u062a 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062d\u0644\u0642\u0629<\/strong><\/td>\n                    <td>\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636<\/td>\n                    <td>\u064a\u0636\u0645\u0646 \u0623\u0646 \u062a\u0643\u0648\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0645\u0646\u062e\u0641\u0636\u0629 \u0628\u0645\u0627 \u064a\u0643\u0641\u064a \u0644\u062a\u062d\u0645\u0644 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/strong><\/td>\n                    <td>\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636\u060c \u0627\u0644\u0647\u064a\u0643\u0644<\/td>\n                    <td>2000 \u062f\u0648\u0631\u0629 \u062a\u0634\u063a\u064a\u0644 \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u0645\u0631 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0648\u0645\u062a\u0627\u0646\u0629 \u0627\u0644\u0622\u0644\u064a\u0629.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0627\u0644\u0627\u0646\u062a\u0642\u0627\u0644 \u0627\u0644\u0632\u062c\u0627\u062c\u064a (Tg)<\/strong><\/td>\n                    <td>\u0645\u0627\u062f\u0629 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a<\/td>\n                    <td>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0639\u0645\u0644\u064a \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0644\u062f\u0641\u0639\u0629 \u0627\u0644\u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0645\u0639\u0627\u0644\u062c.<\/td>\n                <\/tr>\n            <\/table>\n            \n            <p>\n                \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 JN15 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0646\u0627\u060c \u0646\u062c\u0631\u064a \u0623\u064a\u0636\u064b\u0627 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0644\u0641\u062a\u0631\u0629 \u0642\u0635\u064a\u0631\u0629 (\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639) \u0644\u0625\u062b\u0628\u0627\u062a \u0642\u062f\u0631\u062a\u0647\u0627 \u0639\u0644\u0649 \u062a\u0623\u0631\u064a\u0636 \u0639\u0637\u0644 31.5 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u0623\u0648 40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u0628\u0623\u0645\u0627\u0646 \u0644\u0645\u062f\u0629 4 \u062b\u0648\u0627\u0646\u064d \u062f\u0648\u0646 \u062d\u062f\u0648\u062b \u0644\u062d\u0627\u0645 \u0623\u0648 \u062a\u0641\u0643\u0643.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0644\u0645\u0627\u0630\u0627 \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u0639\u0645\u0644 \u0645\u0639 \u0645\u0635\u0646\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0645\u062e\u0635\u0635\u0629<\/h2>\n            <p>\n                \u0644\u0627 \u062a\u062a\u0646\u0627\u0633\u0628 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u062f\u0627\u0626\u0645\u064b\u0627 \u0645\u0639 \u0643\u0644 \u0645\u0634\u0631\u0648\u0639. \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u064a\u0648\u0627\u062c\u0647 \u0645\u0635\u0646\u0639\u0648 \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u062a\u062d\u062f\u064a\u0627\u062a \u0641\u064a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u062a\u062c\u0647\u064a\u0632 \u0623\u0648 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0645\u062d\u062f\u062f\u0629 \u0644\u0644\u0645\u0631\u0627\u0641\u0642. \u064a\u0639\u0645\u0644 \u0645\u0635\u0646\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0645\u062b\u0644 XBRELE \u0643\u0634\u0631\u064a\u0643 \u0647\u0646\u062f\u0633\u064a \u0644\u0643.\n            <\/p>\n            <p>\n                \u0646\u062d\u0646 \u0646\u0642\u062f\u0645 \u062a\u062e\u0635\u064a\u0635\u064b\u0627 \u0639\u0645\u064a\u0642\u064b\u0627 \u0644\u0640 <strong>\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0639\u0632\u0644<\/strong>. \u0625\u0630\u0627 \u0643\u0627\u0646 \u062a\u0631\u062a\u064a\u0628 \u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643 \u064a\u062a\u0637\u0644\u0628 \u062d\u0645\u0644 \u0627\u0646\u062d\u0646\u0627\u0621 \u063a\u064a\u0631 \u0642\u064a\u0627\u0633\u064a \u0623\u0648 \u0645\u0633\u0627\u0641\u0629 \u0632\u062d\u0641 \u0645\u062d\u062f\u062f\u0629 \u0644\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0633\u0627\u062d\u0644\u064a\u060c \u0641\u064a\u0645\u0643\u0646\u0646\u0627 \u062a\u0639\u062f\u064a\u0644 \u0642\u0627\u0644\u0628 APG \u0644\u0625\u0646\u062a\u0627\u062c \u0639\u0627\u0632\u0644 \u0639\u0645\u0648\u062f \u0623\u0648 \u062c\u0644\u0628\u0629 \u062d\u0627\u0626\u0637 \u0645\u062e\u0635\u0635\u0629.\n            <\/p>\n            <p>\n                \u0644\u0640 <strong>\u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>, \u060c \u064a\u0645\u0643\u0646\u0646\u0627 \u062a\u062e\u0635\u064a\u0635 \u0639\u0631\u0636 \u0648\u0633\u0645\u0643 \u0647\u064a\u0643\u0644 \u0634\u0627\u062d\u0646\u0629 VCB \u0644\u062a\u0646\u0627\u0633\u0628 \u0627\u0644\u062e\u0632\u0627\u0646\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u0627\u0644\u0636\u064a\u0642\u0629 650 \u0645\u0645). \u062a\u062a\u064a\u062d \u0647\u0630\u0647 \u0627\u0644\u0645\u0631\u0648\u0646\u0629 \u0644\u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u062a\u0635\u0645\u064a\u0645 \u0645\u0641\u0627\u062a\u064a\u062d \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u062f\u0645\u062c\u0629 \u062f\u0648\u0646 \u0623\u0646 \u064a\u0643\u0648\u0646\u0648\u0627 \u0645\u0642\u064a\u062f\u064a\u0646 \u0628\u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c\u0627\u062a \u0627\u0644\u0635\u0627\u0631\u0645\u0629 \u0644\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0645\u0635\u0646\u0639\u0648 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u064a\u062a\u0645\u062a\u0639\u0648\u0646 \u0628\u062e\u0628\u0631\u0629 \u0648\u0627\u0633\u0639\u0629<\/h2>\n            <p>\n                \u064a\u062a\u0637\u0644\u0628 \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0639\u0642\u0644\u064a\u0629 \u0645\u062e\u062a\u0644\u0641\u0629 \u0639\u0646 \u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u0627\u0644\u0643\u0627\u0645\u0644\u0629. \u0641\u0647\u0648 \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u0639\u0644\u0645 \u0627\u0644\u0645\u0648\u0627\u062f \u0648\u0627\u062a\u0633\u0627\u0642 \u0627\u0644\u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0636\u062e\u0645. \u062a\u062a\u0645\u062a\u0639 XBRELE \u0628\u062e\u0628\u0631\u0629 \u0639\u0642\u0648\u062f \u0637\u0648\u064a\u0644\u0629 \u0641\u064a \u0647\u0630\u0627 \u0627\u0644\u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u062a\u062e\u0635\u0635. \u0646\u062d\u0646 \u0646\u0641\u0647\u0645 \u0645\u0646\u0637\u0642 \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0628\u064a\u0646 \u201c\u0627\u0644\u0648\u0642\u0627\u064a\u0629 \u0627\u0644\u062e\u0645\u0633\u0629\u201d \u0628\u0634\u0643\u0644 \u0639\u0645\u064a\u0642 \u0644\u0623\u0646\u0646\u0627 \u0646\u0635\u0646\u0639 \u0627\u0644\u0623\u0642\u0641\u0627\u0644 \u0646\u0641\u0633\u0647\u0627.\n            <\/p>\n            <p>\n                \u062a\u0634\u0645\u0644 \u062e\u0628\u0631\u062a\u0646\u0627 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062f\u0648\u0644\u064a\u0629. \u0646\u062d\u0646 \u0646\u0639\u0644\u0645 \u0623\u0646 \u0627\u0644\u0628\u0637\u0627\u0646\u0629 \u0627\u0644\u062c\u062f\u0627\u0631\u064a\u0629 \u0644\u0645\u0634\u0631\u0648\u0639 \u0641\u064a \u0631\u0648\u0633\u064a\u0627 (\u0645\u0639\u064a\u0627\u0631 GOST) \u0642\u062f \u062a\u062e\u062a\u0644\u0641 \u0639\u0646 \u062a\u0644\u0643 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0641\u064a \u062c\u0646\u0648\u0628 \u0634\u0631\u0642 \u0622\u0633\u064a\u0627 (\u0645\u0639\u064a\u0627\u0631 IEC). \u064a\u0648\u0644\u064a \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0630\u0648\u0648 \u0627\u0644\u062e\u0628\u0631\u0629 \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0647\u0630\u0647 \u0627\u0644\u0641\u0631\u0648\u0642 \u0627\u0644\u062f\u0642\u064a\u0642\u0629\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0634\u062a\u0631\u064a\u0647\u0627 \u0633\u062a\u062c\u062a\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0646\u0647\u0627\u0626\u064a \u0644\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u062d\u0644\u0648\u0644 \u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u0641\u0639\u0627\u0644\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u062a\u0643\u0644\u0641\u0629<\/h2>\n            <p>\n                \u064a\u0648\u0641\u0631 \u0634\u0631\u0627\u0621 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0646 \u0645\u0635\u0646\u0639 \u0645\u062a\u062e\u0635\u0635 \u0641\u064a \u0627\u0644\u0635\u064a\u0646 \u0645\u064a\u0632\u0629 \u0643\u0628\u064a\u0631\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u062a\u0643\u0644\u0641\u0629. \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0634\u0631\u0627\u0621 \u0645\u0628\u0627\u0634\u0631\u0629 \u0645\u0646 XBRELE\u060c \u064a\u062a\u062c\u0646\u0628 \u0645\u0635\u0646\u0639\u0648 \u0627\u0644\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0647\u0648\u0627\u0645\u0634 \u0627\u0644\u0631\u0628\u062d \u0627\u0644\u062a\u064a \u064a\u0636\u064a\u0641\u0647\u0627 \u0627\u0644\u0645\u0648\u0632\u0639\u0648\u0646 \u0627\u0644\u0645\u062d\u0644\u064a\u0648\u0646. \u064a\u0648\u0641\u0631 \u0645\u0648\u0642\u0639\u0646\u0627 \u0641\u064a \u064a\u0648\u064a\u062a\u0634\u064a\u0646\u063a \u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u0623\u0643\u062b\u0631 \u0643\u0641\u0627\u0621\u0629 \u0641\u064a \u0627\u0644\u0639\u0627\u0644\u0645 \u0644\u0644\u0646\u062d\u0627\u0633 \u0648\u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a.\n            <\/p>\n            <p>\n                \u0646\u0642\u062f\u0645 \u0623\u064a\u0636\u064b\u0627 <strong>CKD (\u062a\u0641\u0643\u064a\u0643 \u0643\u0627\u0645\u0644)<\/strong> \u0648 <strong>SKD<\/strong> \u0645\u062c\u0645\u0648\u0639\u0627\u062a. \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0634\u062d\u0646 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u0636\u062e\u0645\u0629 \u0648\u0627\u0644\u0645\u062c\u0645\u0639\u0629 \u0628\u0627\u0644\u0643\u0627\u0645\u0644\u060c \u064a\u0645\u0643\u0646\u0646\u0627 \u0634\u062d\u0646 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0641\u064a \u0639\u0628\u0648\u0627\u062a \u0645\u062f\u0645\u062c\u0629 \u0644\u062a\u0642\u0648\u0645 \u0628\u062a\u062c\u0645\u064a\u0639\u0647\u0627 \u0645\u062d\u0644\u064a\u064b\u0627. \u0648\u0647\u0630\u0627 \u064a\u0642\u0644\u0644 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0645\u0646 \u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0644\u0634\u062d\u0646 \u0627\u0644\u0628\u062d\u0631\u064a \u0648\u0631\u0633\u0648\u0645 \u0627\u0644\u0627\u0633\u062a\u064a\u0631\u0627\u062f\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644 \u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0623\u0643\u062b\u0631 \u062a\u0646\u0627\u0641\u0633\u064a\u0629 \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u0642\u0635\u0627\u062a \u0627\u0644\u0645\u062d\u0644\u064a\u0629.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0642\u062f\u0631\u0627\u062a \u0625\u0646\u062a\u0627\u062c \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0643\u064a\u0641<\/h2>\n            <p>\n                \u062a\u062a\u0645\u064a\u0632 XBRELE \u0628\u0645\u0631\u0648\u0646\u0629 \u0645\u0644\u062d\u0648\u0638\u0629. \u064a\u0645\u0643\u0646\u0646\u0627 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0648\u0639\u0629 \u0648\u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u062d\u062c\u0645 \u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0625\u0635\u0644\u0627\u062d \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629 (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c 5 \u0635\u0646\u0627\u062f\u064a\u0642 \u062a\u0644\u0627\u0645\u0633 \u0628\u062f\u064a\u0644\u0629) \u0628\u0646\u0641\u0633 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062a\u064a \u0646\u062a\u0639\u0627\u0645\u0644 \u0628\u0647\u0627 \u0645\u0639 \u0627\u0644\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0627\u0644\u062d\u062c\u0645 \u0645\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c 5000 \u0639\u0627\u0632\u0644 \u0639\u0645\u0648\u062f \u0644\u0625\u0646\u062a\u0627\u062c \u0645\u0635\u0646\u0639).\n            <\/p>\n            <p>\n                \u062a\u063a\u0637\u064a \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0646\u062a\u062c\u0627\u062a\u0646\u0627 \u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0628\u064a\u0626\u064a \u0627\u0644\u0643\u0627\u0645\u0644 \u0644\u062e\u0632\u0627\u0646\u0627\u062a KYN28 \u0648 XGN. \u0645\u0646 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0634\u062f\u064a\u062f \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u0648\u062c\u0648\u062f \u0641\u064a \u0627\u0644\u062c\u0632\u0621 \u0627\u0644\u0633\u0641\u0644\u064a \u0645\u0646 \u0627\u0644\u0644\u0648\u062d\u0629 \u0625\u0644\u0649 \u0627\u0644\u0633\u062e\u0627\u0646 \u0627\u0644\u0635\u063a\u064a\u0631 \u0648\u062c\u0647\u0627\u0632 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u062d\u062c\u0631\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u060c \u062a\u0648\u0641\u0631 XBRELE \u062a\u062c\u0631\u0628\u0629 \u201c\u0645\u062a\u062c\u0631 \u0634\u0627\u0645\u0644\u201d. \u062a\u0639\u0645\u0644 \u0647\u0630\u0647 \u0627\u0644\u0642\u0627\u0628\u0644\u064a\u0629 \u0644\u0644\u062a\u0643\u064a\u0641 \u0639\u0644\u0649 \u062a\u0628\u0633\u064a\u0637 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0634\u0631\u0627\u0621\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u0639\u0628\u0621 \u0627\u0644\u0625\u062f\u0627\u0631\u064a \u0644\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0639\u0634\u0631\u0627\u062a \u0645\u0646 \u0627\u0644\u0628\u0627\u0626\u0639\u064a\u0646 \u0627\u0644\u0635\u063a\u0627\u0631.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0633\u062a\u062f\u0627\u0645\u0629<\/h2>\n            <p>\n                \u062a\u0631\u0643\u0632 \u0627\u0644\u0627\u0633\u062a\u062f\u0627\u0645\u0629 \u0641\u064a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0639\u0644\u0649 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0645\u0648\u0627\u062f \u0648\u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u0646\u0641\u0627\u064a\u0627\u062a. \u062a\u0633\u062a\u062e\u062f\u0645 XBRELE \u0622\u0644\u0627\u062a APG \u0645\u062a\u0637\u0648\u0631\u0629 \u0645\u0639 \u062f\u0648\u0631\u0627\u062a \u062a\u0633\u062e\u064a\u0646 \u0645\u062d\u0633\u0651\u0646\u0629 \u0644\u062a\u0642\u0644\u064a\u0644 \u0627\u0633\u062a\u0647\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0623\u062b\u0646\u0627\u0621 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629.\n            <\/p>\n            <p>\n                \u0643\u0645\u0627 \u0646\u0637\u0628\u0642 \u0628\u0631\u0648\u062a\u0648\u0643\u0648\u0644\u0627\u062a \u0635\u0627\u0631\u0645\u0629 \u0644\u0625\u0639\u0627\u062f\u0629 \u062a\u062f\u0648\u064a\u0631 \u062e\u0631\u062f\u0629 \u0627\u0644\u0645\u0639\u0627\u062f\u0646 \u0644\u062f\u064a\u0646\u0627. \u064a\u062a\u0645 \u062c\u0645\u0639 \u0642\u0635\u0627\u0635\u0627\u062a \u0627\u0644\u0646\u062d\u0627\u0633 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0644\u062f\u064a\u0646\u0627 \u0648\u0625\u0639\u0627\u062f\u0629 \u062a\u062f\u0648\u064a\u0631\u0647\u0627\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0647\u062f\u0631 \u0627\u0644\u0645\u0648\u0627\u062f. \u0639\u0644\u0627\u0648\u0629 \u0639\u0644\u0649 \u0630\u0644\u0643\u060c \u062a\u062a\u0648\u0627\u0641\u0642 \u062c\u0645\u064a\u0639 \u0645\u0648\u0627\u062f \u0627\u0644\u0639\u0632\u0644 \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0637\u0644\u0627\u0621 \u0644\u062f\u064a\u0646\u0627 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 RoHS\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643 \u062a\u0644\u0628\u064a \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0645\u0632\u0627\u064a\u0627 \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0635\u064a\u0646\u064a\u0629<\/h2>\n            <p>\n                \u062a\u0639\u062f \u0627\u0644\u0635\u064a\u0646 \u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637. \u0648\u0642\u062f \u062d\u0642\u0642 \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0647\u0646\u0627 \u062d\u062c\u0645 \u0625\u0646\u062a\u0627\u062c \u064a\u062a\u064a\u062d \u0646\u0633\u0628 \u062c\u0648\u062f\u0629 \u0625\u0644\u0649 \u0633\u0639\u0631 \u0644\u0627 \u0645\u062b\u064a\u0644 \u0644\u0647\u0627. \u062a\u0633\u062a\u0641\u064a\u062f XBRELE \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0628\u064a\u0626\u064a \u0644\u062a\u0642\u062f\u0645:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u0627\u0644\u0633\u0631\u0639\u0629:<\/strong> \u064a\u0645\u0643\u0646 \u0625\u0646\u062c\u0627\u0632 \u062a\u0637\u0648\u064a\u0631 \u0642\u0627\u0644\u0628 \u062c\u062f\u064a\u062f \u0644\u0639\u0648\u0627\u0632\u0644 \u0645\u062e\u0635\u0635\u0629 \u0641\u064a \u063a\u0636\u0648\u0646 15 \u064a\u0648\u0645\u064b\u0627 \u0641\u0642\u0637.<\/li>\n                <li><strong>\u0627\u0644\u0633\u0639\u0629:<\/strong> \u064a\u062a\u062c\u0627\u0648\u0632 \u0625\u0646\u062a\u0627\u062c\u0646\u0627 \u0627\u0644\u064a\u0648\u0645\u064a \u0645\u0646 \u0642\u0637\u0639 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a 2000 \u0648\u062d\u062f\u0629\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0642\u062f\u0631\u062a\u0646\u0627 \u0639\u0644\u0649 \u062a\u0644\u0628\u064a\u0629 \u0627\u0644\u0637\u0644\u0628 \u0627\u0644\u0645\u062a\u0632\u0627\u064a\u062f.<\/li>\n                <li><strong>\u0627\u0644\u062a\u0643\u0627\u0645\u0644:<\/strong> \u0646\u0638\u0631\u064b\u0627 \u0644\u0642\u0631\u0628\u0646\u0627 \u0645\u0646 \u0645\u0635\u0646\u0639\u064a VCB\u060c \u0641\u0625\u0646\u0646\u0627 \u0646\u0636\u0645\u0646 \u0623\u0646 \u0645\u0643\u0648\u0646\u0627\u062a\u0646\u0627 (\u0645\u062b\u0644 \u0627\u0644\u0647\u064a\u0643\u0644 \u0648\u0627\u0644\u0645\u0646\u0627\u0641\u0630) \u062a\u062a\u0645\u062a\u0639 \u0628\u062a\u0648\u0627\u0641\u0642 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0645\u062b\u0627\u0644\u064a \u0645\u0639 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0641\u064a \u0627\u0644\u0635\u0646\u0627\u0639\u0629 \u0645\u062b\u0644 VS1 \u0648 VD4.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0644\u0645\u0643\u0648\u0646\u0627\u062a<\/h2>\n            <p>\n                \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0623\u0641\u0636\u0644 \u0645\u0648\u0631\u062f \u0644\u062e\u0637 \u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u0636\u0639 \u0641\u064a \u0627\u0639\u062a\u0628\u0627\u0631\u0643 \u0645\u0627 \u064a\u0644\u064a:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u0634\u0641\u0627\u0641\u064a\u0629 \u0627\u0644\u0645\u0648\u0627\u062f:<\/strong> \u0647\u0644 \u064a\u0630\u0643\u0631 \u0627\u0644\u0645\u0648\u0631\u062f \u062f\u0631\u062c\u0629 \u0646\u0642\u0627\u0621 \u0627\u0644\u0646\u062d\u0627\u0633 \u0648\u062f\u0631\u062c\u0629 \u062c\u0648\u062f\u0629 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a\u061f<\/li>\n                <li><strong>\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631:<\/strong> \u0647\u0644 \u0644\u062f\u064a\u0647\u0645 \u0645\u062e\u062a\u0628\u0631\u0627\u062a \u062f\u0627\u062e\u0644\u064a\u0629 \u0644\u0644\u0623\u0634\u0639\u0629 \u0627\u0644\u0633\u064a\u0646\u064a\u0629 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a\u061f<\/li>\n                <li><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a:<\/strong> \u0647\u0644 \u064a\u0645\u0643\u0646\u0647\u0645 \u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 (\u0639\u0627\u0632\u0644\u0627\u062a + \u0623\u062c\u0647\u0632\u0629 \u0627\u0633\u062a\u0634\u0639\u0627\u0631 + \u0645\u0641\u0627\u062a\u064a\u062d)\u060c \u0623\u0645 \u062c\u0632\u0621 \u0648\u0627\u062d\u062f \u0641\u0642\u0637\u061f<\/li>\n                <li><strong>\u062e\u0628\u0631\u0629 \u0641\u064a \u0627\u0644\u062a\u0635\u062f\u064a\u0631:<\/strong> \u0647\u0644 \u064a\u0641\u0647\u0645\u0648\u0646 \u0643\u064a\u0641\u064a\u0629 \u062a\u063a\u0644\u064a\u0641 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0644\u0644\u062a\u0635\u062f\u064a\u0631 \u0644\u0645\u0646\u0639 \u0643\u0633\u0631 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a\u0629 \u0627\u0644\u0647\u0634\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0646\u0642\u0644\u061f<\/li>\n            <\/ul>\n            <p>\n                \u062a\u0633\u062a\u0648\u0641\u064a XBRELE \u062c\u0645\u064a\u0639 \u0647\u0630\u0647 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0646\u0627 \u0627\u0644\u0634\u0631\u064a\u0643 \u0627\u0644\u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a \u0627\u0644\u0645\u062b\u0627\u0644\u064a \u0644\u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-container\">\n        <div class=\"xbrele-cta-box\">\n            <h2>\u0635\u0646\u0639 \u0645\u0639\u062f\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0623\u0641\u0636\u0644 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0643\u0648\u0646\u0627\u062a XBRELE<\/h2>\n            <p>\u0628\u0633\u0651\u0637 \u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0639\u0648\u0627\u0632\u0644 \u0648\u0623\u062c\u0632\u0627\u0621 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0628\u0627\u0634\u0631\u0629 \u0645\u0646 \u0627\u0644\u0645\u0635\u0646\u0639.<\/p>\n            <a href=\"https:\/\/xbrele.com\/ar\/contact\/\" class=\"xbrele-cta-btn\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0643\u062a\u0627\u0644\u0648\u062c \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Switchgear Component Manufacturer &#038; OEM Solutions Switchgear Component manufacturing is the foundational industry that powers the assembly of Medium Voltage (MV) and High Voltage (HV) electrical panels. It involves the precision engineering of critical &#8220;passive&#8221; parts\u2014such as epoxy insulation, earthing switches, and mechanical interlocks\u2014that ensure the safety and functionality of KYN28, XGN, and Ring Main [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1967","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"top","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/pages\/1967","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=1967"}],"version-history":[{"count":3,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/pages\/1967\/revisions"}],"predecessor-version":[{"id":1993,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/pages\/1967\/revisions\/1993"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=1967"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}