{"id":1537,"date":"2025-11-29T16:51:39","date_gmt":"2025-11-29T16:51:39","guid":{"rendered":"https:\/\/xbrele.com\/difference-between-vcb-and-contactor-in-electrical-systems\/"},"modified":"2026-04-07T15:12:19","modified_gmt":"2026-04-07T15:12:19","slug":"difference-between-vcb-and-contactor-in-electrical-systems","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/difference-between-vcb-and-contactor-in-electrical-systems\/","title":{"rendered":"\u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 vcb \u0648\u0627\u0644\u0645\u0648\u0635\u0644"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e.webp\" alt=\"\u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 vcb \u0648\u0627\u0644\u0645\u0648\u0635\u0644\" class=\"wp-image-1535\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0635\u062f\u0631 \u0627\u0644\u0635\u0648\u0631\u0629: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">pexels<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0641\u0647\u0645 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (contactor) \u0644\u0627\u062a\u062e\u0627\u0630 \u062e\u064a\u0627\u0631\u0627\u062a \u0622\u0645\u0646\u0629 \u0648\u0641\u0639\u0627\u0644\u0629 \u0641\u064a \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u064a\u0639\u0645\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0639\u0644\u0649 \u0642\u0637\u0639 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0648\u0625\u0637\u0641\u0627\u0621 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0628\u0633\u0631\u0639\u0629\u060c \u0645\u0645\u0627 \u064a\u062d\u0645\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u062c\u0648\u062f\u0629 \u0627\u0644\u0637\u0627\u0642\u0629. \u064a\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u064a\u0633\u0645\u062d \u0628\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647 \u0645\u0648\u062b\u0648\u0642\u064b\u0627 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u064a\u0648\u0645\u064a\u0629. \u064a\u0633\u0627\u0639\u062f\u0643 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0639\u0644\u0649 \u062a\u062c\u0646\u0628 \u0625\u0647\u062f\u0627\u0631 \u0627\u0644\u0645\u0648\u0627\u0631\u062f \u0648\u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u062a\u0643\u0627\u0644\u064a\u0641 \u0648\u0636\u0645\u0627\u0646 \u0633\u0647\u0648\u0644\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0639\u0645\u0644 VCBs \u0639\u0644\u0649 \u062a\u062d\u0633\u064a\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0639\u0646 \u0637\u0631\u064a\u0642 \u062a\u0642\u0644\u064a\u0644 \u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0625\u0637\u0627\u0644\u0629 \u0639\u0645\u0631\u0647\u0627 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062f\u0639\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0641\u0639\u0627\u0644 \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0645\u0646 \u0641\u064a \u0627\u0644\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u0627\u0644\u0633\u0648\u0642 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0644\u0647\u0630\u0647 \u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0622\u062e\u0630\u0629 \u0641\u064a \u0627\u0644\u0646\u0645\u0648\u060c \u0644\u0627 \u0633\u064a\u0645\u0627 \u0641\u064a \u0645\u0646\u0637\u0642\u0629 \u0622\u0633\u064a\u0627 \u0648\u0627\u0644\u0645\u062d\u064a\u0637 \u0627\u0644\u0647\u0627\u062f\u0626\u060c \u0628\u0633\u0628\u0628 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0633\u0631\u064a\u0639.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u062d\u0645\u064a VCBs \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0639\u0637\u0644\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0632\u0627\u0626\u062f.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0641\u064a \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u0645\u0645\u0627 \u064a\u0633\u0645\u062d \u0628\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0628\u064a\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u0625\u064a\u0642\u0627\u0641 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u0627\u062e\u062a\u0631 VCB \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0648\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062d\u0631\u062c\u0629\u061b \u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0648\u0635\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0639\u0627\u062f\u064a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u0645\u062a\u0639 VCBs \u0628\u0642\u062f\u0631\u0629 \u0639\u0627\u0644\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647\u0627 \u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0644\u0623\u0646\u0638\u0645\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0625\u0644\u0649 \u0627\u0644\u0639\u0627\u0644\u064a.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0632\u064a\u062f\u064b\u0627 \u0645\u0646 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0628\u0633\u0628\u0628 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u062a\u0645\u062a\u0639 VCBs \u0628\u0641\u062a\u0631\u0627\u062a \u0635\u064a\u0627\u0646\u0629 \u0623\u0637\u0648\u0644.<\/p><\/li>\n\n\n\n<li><p>\u0641\u0647\u0645 \u0627\u0644\u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u064a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u060c \u0645\u0645\u0627 \u064a\u062d\u0633\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0641\u064a \u0646\u0638\u0627\u0645\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p><\/li>\n\n\n\n<li><p>\u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u0645\u0637\u0627\u0628\u0642\u0629 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0639 \u062c\u0647\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0648\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0623\u0645\u062b\u0644.<\/p><\/li>\n\n\n\n<li><p>\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062f\u0648\u0631\u064a\u0629 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629\u061b \u062a\u062d\u062a\u0627\u062c VCBs \u0625\u0644\u0649 \u0641\u062d\u0635 \u0643\u0644 1-3 \u0633\u0646\u0648\u0627\u062a\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0625\u0644\u0649 \u0641\u062d\u0648\u0635\u0627\u062a \u0623\u0643\u062b\u0631 \u062a\u0648\u0627\u062a\u0631\u0627\u064b.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"difference-between-vcb-and-contactor\">\u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"VCU \u0648 VCB - \u0627\u0644\u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a: \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 - \u0648\u062d\u062f\u0629 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0641\u0631\u0627\u063a\u064a \u0648\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\" width=\"1290\" height=\"968\" src=\"https:\/\/www.youtube.com\/embed\/mwd5eFAfCXA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-definition\">\u062a\u0639\u0631\u064a\u0641 VCB<\/h3>\n\n\n\n<p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u060c \u0623\u0648 VCB\u060c \u0647\u0648 \u062c\u0647\u0627\u0632 \u064a\u0633\u062a\u062e\u062f\u0645 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644. \u0641\u0647\u0648 \u064a\u0642\u0637\u0639 \u062a\u062f\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0639\u0646\u062f\u0645\u0627 \u064a\u0643\u062a\u0634\u0641 \u0645\u0634\u0627\u0643\u0644 \u0645\u062b\u0644 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0632\u0627\u0626\u062f \u0623\u0648 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629. \u062a\u0633\u062a\u062e\u062f\u0645 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a \u0644\u0625\u0637\u0641\u0627\u0621 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0630\u064a \u064a\u062a\u0634\u0643\u0644 \u0639\u0646\u062f \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629. \u062a\u062d\u0627\u0641\u0638 \u0647\u0630\u0647 \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0645\u0639\u062f\u0627\u062a\u0643 \u0648\u062a\u0633\u0627\u0639\u062f \u0641\u064a \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u0637\u0627\u0642\u0629.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"main-function\">\u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h4>\n\n\n\n<p>\u0623\u0646\u062a \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 VCB \u0644\u0648\u0642\u0641 \u062a\u062f\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0641\u064a \u0627\u0644\u0645\u0648\u0627\u0642\u0641 \u0627\u0644\u062e\u0637\u0631\u0629. \u0648\u062a\u062a\u0645\u062b\u0644 \u0648\u0638\u064a\u0641\u062a\u0647 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0641\u064a \u062d\u0645\u0627\u064a\u0629 \u0646\u0638\u0627\u0645\u0643 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0642\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0628\u0633\u0631\u0639\u0629 \u0639\u0646\u062f\u0645\u0627 \u064a\u0633\u062a\u0634\u0639\u0631 \u0648\u062c\u0648\u062f \u0639\u0637\u0644. \u0648\u064a\u0645\u0646\u0639 \u0647\u0630\u0627 \u0627\u0644\u0625\u062c\u0631\u0627\u0621 \u062a\u0644\u0641 \u0645\u0639\u062f\u0627\u062a\u0643 \u0648\u064a\u0642\u0644\u0644 \u0645\u0646 \u062e\u0637\u0631 \u0646\u0634\u0648\u0628 \u062d\u0631\u064a\u0642 \u0623\u0648 \u0645\u062e\u0627\u0637\u0631 \u0623\u062e\u0631\u0649.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"protection-role\">\u062f\u0648\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/h4>\n\n\n\n<p>\u064a\u0639\u0645\u0644 VCB \u0643\u062f\u0631\u0639 \u0648\u0627\u0642\u064a \u0644\u0634\u0628\u0643\u062a\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0641\u0647\u0648 \u064a\u0639\u0632\u0644 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u0639\u064a\u0628\u0629 \u0648\u064a\u0645\u0646\u0639 \u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u0648\u062b\u0648\u0642 \u0641\u064a VCB \u0644\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0625\u0644\u0649 \u0627\u0644\u0639\u0627\u0644\u064a\u060c \u0648\u0627\u0644\u062a\u064a \u062a\u062a\u0631\u0627\u0648\u062d \u0639\u0627\u062f\u0629\u064b \u0645\u0646 1 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0625\u0644\u0649 38 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644\u0647 \u062c\u0632\u0621\u064b\u0627 \u0623\u0633\u0627\u0633\u064a\u064b\u0627 \u0645\u0646 \u0623\u0646\u0638\u0645\u0629 \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"contactor-definition\">\u062a\u0639\u0631\u064a\u0641 \u0627\u0644\u0645\u0644\u0627\u0645\u0633<\/h3>\n\n\n\n<p>\u0627\u0644\u0645\u0648\u0635\u0644 \u0647\u0648 \u062c\u0647\u0627\u0632 \u064a\u0633\u062a\u062e\u062f\u0645 \u0644\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u062a\u062f\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0641\u064a \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u064a\u0639\u0645\u0644 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0641\u062a\u062d \u0648\u0625\u063a\u0644\u0627\u0642 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0628\u0645\u0633\u0627\u0639\u062f\u0629 \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0639\u0646\u062f \u062a\u0632\u0648\u064a\u062f \u0627\u0644\u0645\u0644\u0641 \u0628\u0627\u0644\u0637\u0627\u0642\u0629\u060c \u062a\u063a\u0644\u0642 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u062a\u062a\u062f\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0625\u0644\u0649 \u0627\u0644\u062d\u0645\u0644\u060c \u0645\u062b\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0623\u0648 \u0646\u0638\u0627\u0645 \u0627\u0644\u0625\u0636\u0627\u0621\u0629. \u0639\u0646\u062f \u0642\u0637\u0639 \u0627\u0644\u0637\u0627\u0642\u0629 \u0639\u0646 \u0627\u0644\u0645\u0644\u0641\u060c \u062a\u0641\u062a\u062d \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u062a\u0648\u0642\u0641 \u0627\u0644\u062a\u064a\u0627\u0631.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"main-function\">\u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h4>\n\n\n\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0625\u064a\u0642\u0627\u0641\u0647\u0627. \u0647\u0630\u0627 \u0627\u0644\u062c\u0647\u0627\u0632 \u0634\u0627\u0626\u0639 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0648\u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629. \u0641\u0647\u0648 \u064a\u062a\u064a\u062d \u0644\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0628\u0623\u0645\u0627\u0646 \u0648\u0643\u0641\u0627\u0621\u0629\u060c \u062e\u0627\u0635\u0629\u064b \u0639\u0646\u062f\u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"actuator-role\">\u062f\u0648\u0631 \u0627\u0644\u0645\u0634\u063a\u0644<\/h4>\n\n\n\n<p>\u064a\u0639\u0645\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0643\u0648\u062d\u062f\u0629 \u062a\u0634\u063a\u064a\u0644 \u0641\u064a \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643. \u0641\u0647\u0648 \u064a\u0633\u062a\u062c\u064a\u0628 \u0644\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u0635\u0627\u062f\u0631\u0629 \u0645\u0646 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u064a\u062f\u064a\u0631 \u062a\u062f\u0641\u0642 \u0627\u0644\u0637\u0627\u0642\u0629 \u0625\u0644\u0649 \u0627\u0644\u0622\u0644\u0627\u062a \u0623\u0648 \u0627\u0644\u0645\u0639\u062f\u0627\u062a. \u062a\u0636\u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0633\u0644\u0627\u0645\u062a\u0643 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0646\u0639 \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0627\u0644\u0645\u0628\u0627\u0634\u0631 \u0628\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"key-distinctions\">\u0627\u0644\u0641\u0631\u0648\u0642 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0641\u0647\u0645 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 vcb \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0644\u062a\u0637\u0628\u064a\u0642\u0643. \u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u0627\u0644\u0641\u0631\u0648\u0642 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u064a\u062d\u0645\u064a VCB \u0646\u0638\u0627\u0645\u0643 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0639\u064a\u0628\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u064a\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u0646\u062a\u0638\u0645 \u0644\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u0642\u062f \u064a\u0633\u062a\u062e\u062f\u0645 \u0643\u0644\u0627 \u0627\u0644\u062c\u0647\u0627\u0632\u064a\u0646 \u062a\u0642\u0646\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u060c \u0648\u0644\u0643\u0646 \u0623\u063a\u0631\u0627\u0636\u0647\u0645\u0627 \u062a\u062e\u062a\u0644\u0641. \u062a\u0633\u062a\u062e\u062f\u0645 VCB \u0644\u0644\u0623\u0645\u0627\u0646 \u0648\u0639\u0632\u0644 \u0627\u0644\u0623\u0639\u0637\u0627\u0644\u060c \u0648\u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0644\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u0639\u0627\u0645\u0644 VCBs \u0645\u0639 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u062a\u0648\u0633\u0637\u0629 \u0625\u0644\u0649 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0648\u062a\u0639\u0645\u0644 \u062e\u0644\u0627\u0644 \u0627\u0644\u0623\u062d\u062f\u0627\u062b \u0627\u0644\u062d\u0631\u062c\u0629. \u062a\u0639\u0645\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0639 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0625\u0644\u0649 \u0627\u0644\u0645\u062a\u0648\u0633\u0637\u0629 \u0648\u062a\u0642\u0648\u0645 \u0628\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u062d\u0631\u0635 \u062f\u0627\u0626\u0645\u064b\u0627 \u0639\u0644\u0649 \u0645\u0637\u0627\u0628\u0642\u0629 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0639 \u062c\u0647\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0648\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u064a\u0648\u0636\u062d \u0627\u0644\u0623\u062f\u0648\u0627\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629 \u0648\u0646\u0637\u0627\u0642\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0646\u0648\u0639 \u0627\u0644\u062c\u0647\u0627\u0632<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062f\u0648\u0631 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0639\u0632\u0644 \u0627\u0644\u0623\u0639\u0637\u0627\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 (1 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0625\u0644\u0649 38 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u0635\u0644 \u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a\u0647\u0627<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0635\u0646\u0627\u0639\u064a\u0629 \u0645\u062a\u0646\u0648\u0639\u0629<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0633\u062a\u062c\u062f VCBs \u0641\u064a \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0623\u0639\u0637\u0627\u0644\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0628\u0634\u0643\u0644 \u0634\u0627\u0626\u0639 \u0641\u064a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0648\u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u0645\u0628\u0627\u0646\u064a \u0648\u0627\u0644\u062a\u0635\u0646\u064a\u0639.<\/p>\n\n\n\n<p>\u064a\u0638\u0647\u0631 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u064a\u0636\u064b\u0627 \u0641\u064a \u062a\u0642\u0646\u064a\u0629 \u0642\u0637\u0639 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u062a\u0633\u062a\u062e\u062f\u0645 VCBs \u0642\u0627\u0637\u0639 \u0641\u0631\u0627\u063a \u0644\u0636\u0645\u0627\u0646 \u0625\u062e\u0645\u0627\u062f \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0628\u0634\u0643\u0644 \u0641\u0627\u0626\u0642\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647\u0627 \u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0639\u0637\u0644. \u0644\u0645 \u064a\u062a\u0645 \u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0639\u0637\u0644\u060c \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062a\u0645\u064a\u0632 \u0628\u0642\u062f\u0631\u0629 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0648\u062a\u0635\u0645\u064a\u0645\u0647\u0627 \u0627\u0644\u0628\u0633\u064a\u0637.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0633\u062a\u062e\u062f\u0645 VCBs \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629 \u0627\u0644\u0639\u0631\u0636\u064a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0641\u064a \u062f\u0648\u0631\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u0625\u064a\u0642\u0627\u0641 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629 \u0641\u064a \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0641\u0647\u0645 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 vcb \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u064a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u0627\u062a\u062e\u0627\u0630 \u0642\u0631\u0627\u0631\u0627\u062a \u0645\u0633\u062a\u0646\u064a\u0631\u0629 \u0648\u062d\u0645\u0627\u064a\u0629 \u0645\u0639\u062f\u0627\u062a\u0643 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u064a\u0631 \u0639\u0645\u0644\u064a\u0627\u062a\u0643 \u0628\u0633\u0644\u0627\u0633\u0629.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"operation-and-performance\">\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u0623\u062f\u0627\u0621<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"switching-frequency\">\u062a\u0631\u062f\u062f \u0627\u0644\u062a\u0628\u062f\u064a\u0644<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0636\u0639 \u0641\u064a \u0627\u0639\u062a\u0628\u0627\u0631\u0643 \u062a\u0631\u062f\u062f \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0639\u0646\u062f\u0645\u0627 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0627\u062e\u062a\u0631 \u0628\u064a\u0646 VCB<\/a> \u0648\u0648\u062d\u062f\u0629 \u062a\u0648\u0635\u064a\u0644. \u064a\u0639\u0646\u064a \u062a\u0631\u062f\u062f \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0639\u062f\u062f \u0627\u0644\u0645\u0631\u0627\u062a \u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646\u0643 \u0641\u064a\u0647\u0627 \u0641\u062a\u062d \u0627\u0644\u062c\u0647\u0627\u0632 \u0648\u0625\u063a\u0644\u0627\u0642\u0647 \u062f\u0648\u0646 \u0627\u0644\u062a\u0633\u0628\u0628 \u0641\u064a \u062a\u0644\u0641\u0647. \u062a\u0633\u062a\u062e\u062f\u0645 \u0648\u062d\u062f\u0629 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0641\u064a \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u062a\u0628\u062f\u064a\u0644\u064b\u0627 \u0645\u062a\u0643\u0631\u0631\u064b\u0627. \u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c \u0642\u062f \u062a\u0642\u0648\u0645 \u0628\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0623\u0648 \u0627\u0644\u0623\u0636\u0648\u0627\u0621 \u0648\u0625\u064a\u0642\u0627\u0641\u0647\u0627 \u0639\u062f\u0629 \u0645\u0631\u0627\u062a \u0643\u0644 \u064a\u0648\u0645. \u064a\u0645\u0643\u0646 \u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0622\u0644\u0627\u0641 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0641\u064a \u0627\u0644\u0633\u0627\u0639\u0629. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644\u0647\u0627 \u0645\u062b\u0627\u0644\u064a\u0629 \u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645.<\/p>\n\n\n\n<p>\u064a\u0639\u0645\u0644 VCB \u0628\u0634\u0643\u0644 \u0645\u062e\u062a\u0644\u0641. \u062a\u0633\u062a\u062e\u062f\u0645 VCB \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0639\u0631\u0636\u064a\u060c \u0639\u0627\u062f\u0629\u064b \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0623\u0648 \u0627\u0644\u0635\u064a\u0627\u0646\u0629. \u0644\u0627 \u064a\u0645\u0643\u0646 \u0644\u0640 VCB \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629. \u0625\u0630\u0627 \u062d\u0627\u0648\u0644\u062a \u0627\u0633\u062a\u062e\u062f\u0627\u0645 VCB \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u0646\u062a\u0638\u0645\u060c \u0641\u0633\u0648\u0641 \u062a\u062a\u0622\u0643\u0644 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0628\u0633\u0631\u0639\u0629. \u064a\u062c\u0628 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 VCB \u0641\u0642\u0637 \u0639\u0646\u062f\u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0639\u0627\u0644\u064a \u0623\u0648 \u062d\u0645\u0627\u064a\u0629 \u0646\u0638\u0627\u0645\u0643 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u062e\u062a\u0631 \u0645\u0648\u0635\u0644\u064b\u0627 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0648\u0645\u0641\u062a\u0627\u062d\u064b\u0627 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u064b\u0627 \u0644\u0644\u0627\u0646\u0642\u0637\u0627\u0639\u0627\u062a \u0627\u0644\u0646\u0627\u062f\u0631\u0629 \u0648\u0627\u0644\u062d\u0627\u0633\u0645\u0629.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"interrupting-capacity\">\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629<\/h3>\n\n\n\n<p>\u062a\u062d\u062f\u062f \u0633\u0639\u0629 \u0627\u0644\u0642\u0637\u0639 \u0645\u0642\u062f\u0627\u0631 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0630\u064a \u064a\u0645\u0643\u0646 \u0644\u0644\u062c\u0647\u0627\u0632 \u0642\u0637\u0639\u0647 \u0628\u0623\u0645\u0627\u0646. \u064a\u062c\u0628 \u0645\u0639\u0631\u0641\u0629 \u0647\u0630\u0647 \u0627\u0644\u0642\u064a\u0645\u0629 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a. \u062a\u062a\u0645\u064a\u0632 VCB \u0628\u0633\u0639\u0629 \u0642\u0637\u0639 \u0639\u0627\u0644\u064a\u0629. \u064a\u0645\u0643\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647\u0627 \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637. \u0647\u0630\u0647 \u0627\u0644\u0645\u064a\u0632\u0629 \u062a\u062c\u0639\u0644 VCB \u0645\u0647\u0645\u0629 \u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629.<\/p>\n\n\n\n<p>\u064a\u062a\u0645\u062a\u0639 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0628\u0642\u062f\u0631\u0629 \u0642\u0637\u0639 \u0623\u0642\u0644 \u0628\u0643\u062b\u064a\u0631. \u0644\u0627 \u064a\u062c\u0628 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0639\u064a\u0628\u0629. \u0625\u0630\u0627 \u062d\u0627\u0648\u0644\u062a \u0630\u0644\u0643\u060c \u0641\u0642\u062f \u064a\u062a\u0639\u0637\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0648\u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u062d\u062f\u0648\u062b \u0623\u0636\u0631\u0627\u0631. \u064a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0639\u0627\u062f\u064a\u0629\u060c \u0648\u0644\u064a\u0633 \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0639\u064a\u0628\u0629. \u0647\u0630\u0627 \u0647\u0648 \u0627\u0644\u0641\u0631\u0642 \u0627\u0644\u0631\u0626\u064a\u0633\u064a \u0628\u064a\u0646 vcb \u0648\u0627\u0644\u0645\u0644\u0627\u0645\u0633.<\/p>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u0628\u0633\u064a\u0637 \u0644\u0645\u0633\u0627\u0639\u062f\u062a\u0643 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062c\u0647\u0627\u0632<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>VCB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062e\u0644\u0644<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u0635\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u062d\u0645\u0644 (\u0628\u062f\u0648\u0646 \u0623\u0639\u0637\u0627\u0644)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"arc-interruption\">\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0642\u0648\u0633<\/h3>\n\n\n\n<p>\u0639\u0646\u062f \u0641\u062a\u062d \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u064a\u062a\u0634\u0643\u0644 \u0642\u0648\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0628\u064a\u0646 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633. \u064a\u062c\u0628 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0647\u0630\u0627 \u0627\u0644\u0642\u0648\u0633 \u0644\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u064a \u062a\u0644\u0641. \u064a\u0633\u062a\u062e\u062f\u0645 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0642\u0627\u0637\u0639 \u0641\u0631\u0627\u063a\u064a \u0644\u0625\u0637\u0641\u0627\u0621 \u0627\u0644\u0642\u0648\u0633 \u0628\u0633\u0631\u0639\u0629. \u064a\u0639\u0645\u0644 \u0627\u0644\u0641\u0631\u0627\u063a \u0639\u0644\u0649 \u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0647\u0648\u0627\u0621\u060c \u0648\u0628\u0627\u0644\u062a\u0627\u0644\u064a \u0644\u0627 \u064a\u0633\u062a\u0645\u0631 \u0627\u0644\u0642\u0648\u0633 \u0644\u0641\u062a\u0631\u0629 \u0637\u0648\u064a\u0644\u0629. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 (VCB) \u0641\u0639\u0627\u0644\u0629 \u0644\u0644\u063a\u0627\u064a\u0629 \u0641\u064a \u0625\u064a\u0642\u0627\u0641 \u0627\u0644\u0623\u0642\u0648\u0627\u0633 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a.<\/p>\n\n\n\n<p>\u064a\u0642\u0648\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0623\u064a\u0636\u064b\u0627 \u0628\u0642\u0637\u0639 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0644\u0643\u0646\u0647 \u0644\u0627 \u064a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0641\u0631\u0627\u063a. \u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0639\u0638\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0647\u0648\u0627\u0621 \u0623\u0648 \u0645\u0648\u0627\u062f \u062e\u0627\u0635\u0629 \u0644\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u064a\u0639\u0645\u0644 \u0647\u0630\u0627 \u0628\u0634\u0643\u0644 \u062c\u064a\u062f \u0645\u0639 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0648\u0627\u0644\u0645\u062a\u0648\u0633\u0637\u0629. \u0648\u0645\u0639 \u0630\u0644\u0643\u060c \u0644\u0627 \u062a\u0633\u062a\u0637\u064a\u0639 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0623\u0642\u0648\u0627\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0642\u0648\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u062d\u062f\u062b \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0623\u0639\u0637\u0627\u0644. \u064a\u062c\u0628 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 VCB \u0644\u0642\u0637\u0639 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0627\u0644\u0645\u0648\u0627\u0642\u0641 \u0627\u0644\u062d\u0631\u062c\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u062a\u0630\u0643\u0631: \u062a\u062a\u0645\u064a\u0632 VCBs \u0628\u0627\u0645\u062a\u064a\u0627\u0632\u0647\u0627 \u0641\u064a \u0642\u0637\u0639 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0623\u0639\u0637\u0627\u0644\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u062a\u0648\u0644\u0649 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u064a\u0648\u0645\u064a\u0629 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0637\u0627\u0642\u0629 \u0642\u0648\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u0642\u0644.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"current-chop\">\u0627\u0644\u0642\u0637\u0639 \u0627\u0644\u062d\u0627\u0644\u064a<\/h3>\n\n\n\n<p>\u0642\u062f \u062a\u0644\u0627\u062d\u0638 \u0633\u0644\u0648\u0643\u064b\u0627 \u0641\u0631\u064a\u062f\u064b\u0627 \u064a\u0633\u0645\u0649 \u201c\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u201d \u0639\u0646\u062f \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB). \u064a\u062d\u062f\u062b \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0639\u0646\u062f\u0645\u0627 \u064a\u0642\u0637\u0639 \u0627\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0642\u0628\u0644 \u0623\u0646 \u064a\u0635\u0644 \u0628\u0634\u0643\u0644 \u0637\u0628\u064a\u0639\u064a \u0625\u0644\u0649 \u0627\u0644\u0635\u0641\u0631. \u0647\u0630\u0627 \u0627\u0644\u062a\u0623\u062b\u064a\u0631 \u0623\u0643\u062b\u0631 \u0634\u064a\u0648\u0639\u064b\u0627 \u0641\u064a \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0645\u0646\u0647 \u0641\u064a \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a. \u062a\u0633\u0645\u062d \u0641\u064a\u0632\u064a\u0627\u0621 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0628\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0641\u064a \u0645\u0633\u0627\u062d\u0629 \u0623\u0635\u063a\u0631 \u0628\u0643\u062b\u064a\u0631. \u0648\u0647\u0630\u0627 \u064a\u0639\u0646\u064a \u0623\u0646 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062f\u0627\u062e\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062a\u0648\u0642\u0641 \u0641\u062c\u0623\u0629\u060c \u062d\u062a\u0649 \u0644\u0648 \u0644\u0645 \u064a\u0635\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0625\u0644\u0649 \u0646\u0647\u0627\u064a\u062a\u0647 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629.<\/p>\n\n\n\n<p>\u0639\u0646\u062f \u0627\u0633\u062a\u062e\u062f\u0627\u0645 VCB\u060c \u064a\u0635\u0628\u062d \u0639\u0645\u0648\u062f \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0628\u062f\u0627\u062e\u0644\u0647 \u063a\u064a\u0631 \u0645\u0633\u062a\u0642\u0631. \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0639\u0648\u0627\u0645\u0644 \u0645\u062b\u0644 \u0636\u063a\u0637 \u0627\u0644\u0628\u062e\u0627\u0631 \u0648\u0637\u0631\u064a\u0642\u0629 \u0627\u0646\u062a\u0642\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0639\u0628\u0631 \u0645\u0627\u062f\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0641\u064a \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0628\u0643\u0631\u064b\u0627. \u064a\u0624\u062f\u064a \u0647\u0630\u0627 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0645\u0628\u0643\u0631 \u0625\u0644\u0649 \u062d\u062f\u0648\u062b \u062a\u0642\u0644\u0628\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u0648\u0641\u0648\u0644\u062a\u064a\u0629 \u0632\u0627\u0626\u062f\u0629. \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0647\u0630\u0647 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0625\u0644\u0649 \u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0627\u0644\u0639\u0632\u0644. \u0644\u0627 \u062a\u0638\u0647\u0631 \u0647\u0630\u0647 \u0627\u0644\u0622\u062b\u0627\u0631 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0645\u0639 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a. \u0644\u0627 \u062a\u0642\u0637\u0639 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0628\u0646\u0641\u0633 \u0627\u0644\u0637\u0631\u064a\u0642\u0629\u060c \u0644\u0630\u0627 \u0646\u0627\u062f\u0631\u064b\u0627 \u0645\u0627 \u062a\u062a\u0633\u0628\u0628 \u0641\u064a \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0623\u0648 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0632\u0627\u0626\u062f\u0629 \u0627\u0644\u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0647.<\/p>\n\n\n\n<p>\u064a\u0645\u0643\u0646 \u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0642\u0637\u0639 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0623\u064a\u0636\u064b\u0627 \u0642\u0637\u0639 \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0639\u0627\u0644\u064a \u0627\u0644\u062a\u0631\u062f\u062f \u0623\u062b\u0646\u0627\u0621 \u0623\u062d\u062f\u0627\u062b \u0645\u062b\u0644 \u0627\u0644\u0636\u0631\u0628\u0629 \u0627\u0644\u0645\u0633\u0628\u0642\u0629 \u0648\u062a\u0642\u0637\u064a\u0639 \u0627\u0644\u062a\u064a\u0627\u0631. \u0648\u062a\u062a\u064a\u062d \u062e\u0635\u0627\u0626\u0635\u0647\u0627 \u0627\u0644\u0639\u0627\u0632\u0644\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u062a\u062d\u0642\u064a\u0642 \u0630\u0644\u0643. \u064a\u062c\u0628 \u0623\u0646 \u062a\u0639\u0644\u0645 \u0623\u0646 \u0647\u0630\u0647 \u0627\u0644\u0633\u0644\u0648\u0643\u064a\u0627\u062a \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0625\u0644\u0649 \u0627\u0633\u062a\u062c\u0627\u0628\u0627\u062a \u0645\u062e\u062a\u0644\u0641\u0629 \u0644\u0644\u0646\u0638\u0627\u0645 \u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a. \u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0639\u0645\u0644 \u0645\u0639 \u0645\u0639\u062f\u0627\u062a \u062d\u0633\u0627\u0633\u0629 \u0623\u0648 \u0643\u0627\u0628\u0644\u0627\u062a \u0637\u0648\u064a\u0644\u0629\u060c \u0641\u064a\u062c\u0628 \u0623\u0646 \u062a\u0636\u0639 \u0641\u064a \u0627\u0639\u062a\u0628\u0627\u0631\u0643 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0632\u0627\u0626\u062f \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646 \u062a\u0642\u0637\u064a\u0639 \u0627\u0644\u062a\u064a\u0627\u0631.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0627\u0644\u0642\u0637\u0639 \u0627\u0644\u062d\u0627\u0644\u064a \u0647\u0648 \u0623\u062d\u062f \u0627\u0644\u0623\u0633\u0628\u0627\u0628 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u062c\u0639\u0644\u0643 \u062a\u0636\u0637\u0631 \u0625\u0644\u0649 \u0645\u0637\u0627\u0628\u0642\u0629 \u0646\u0648\u0639 \u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u0639 \u0646\u0638\u0627\u0645\u0643. \u0642\u062f \u064a\u0624\u062f\u064a \u0627\u0633\u062a\u062e\u062f\u0627\u0645 VCB \u0641\u064a \u0627\u0644\u0645\u0643\u0627\u0646 \u0627\u0644\u062e\u0637\u0623 \u0625\u0644\u0649 \u062d\u062f\u0648\u062b \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u063a\u064a\u0631 \u0645\u0631\u063a\u0648\u0628 \u0641\u064a\u0647\u0627 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u0645\u0642\u0627\u0631\u0646\u0629 \u0633\u0631\u064a\u0639\u0629:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u064a\u0632\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>VCB (\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u0635\u0644<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0642\u0637\u0639 \u0627\u0644\u062d\u0627\u0644\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0634\u0627\u0626\u0639<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0627\u062f\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062e\u0637\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0632\u0627\u0626\u062f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0639\u0644\u0649<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0642\u0648\u0633<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0641\u0627\u062c\u0626\u060c \u0641\u064a \u0623\u064a \u0648\u0642\u062a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0641\u064a \u0627\u0644\u0635\u0641\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-voltage\">\u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645<\/h3>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0643\u0644 \u0645\u0646 VCBs \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u062c\u0647\u062f \u062a\u062d\u0643\u0645. \u064a\u0639\u0645\u0644 \u0647\u0630\u0627 \u0627\u0644\u062c\u0647\u062f \u0639\u0644\u0649 \u062a\u0646\u0634\u064a\u0637 \u0627\u0644\u0645\u0644\u0641 \u0623\u0648 \u0627\u0644\u0645\u0634\u063a\u0644 \u062f\u0627\u062e\u0644 \u0627\u0644\u062c\u0647\u0627\u0632. \u0639\u0646\u062f \u062a\u0637\u0628\u064a\u0642 \u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0635\u062d\u064a\u062d\u060c \u064a\u0639\u0645\u0644 \u0627\u0644\u062c\u0647\u0627\u0632 \u2014 \u0625\u0645\u0627 \u0628\u0641\u062a\u062d \u0623\u0648 \u0625\u063a\u0644\u0627\u0642 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633.<\/p>\n\n\n\n<p>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0641\u0627\u062a\u064a\u062d VCB\u060c \u0639\u0627\u062f\u0629 \u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062c\u0647\u062f \u062a\u062d\u0643\u0645 \u0623\u0639\u0644\u0649. \u0648\u0630\u0644\u0643 \u0644\u0623\u0646 \u0627\u0644\u0622\u0644\u064a\u0629 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629 \u064a\u062c\u0628 \u0623\u0646 \u062a\u062d\u0631\u0643 \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0623\u0643\u0628\u0631 \u0648\u0623\u062b\u0642\u0644 \u0648\u062a\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0637\u0627\u0642\u0629 \u0623\u0639\u0644\u0649. \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0631\u0649 \u062c\u0647\u062f \u062a\u062d\u0643\u0645 \u0645\u062b\u0644 110 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0623\u0648 220 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0623\u0648 \u062d\u062a\u0649 \u0623\u0639\u0644\u0649 \u0641\u064a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637.<\/p>\n\n\n\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u062c\u0647\u062f \u062a\u062d\u0643\u0645 \u0623\u0642\u0644. \u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 24 \u0641\u0648\u0644\u062a \u0623\u0648 48 \u0641\u0648\u0644\u062a \u0623\u0648 110 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f \u0623\u0648 \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631\u060c \u062d\u0633\u0628 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0644\u062f\u064a\u0643. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0633\u0647\u0644\u0629 \u0627\u0644\u062f\u0645\u062c \u0641\u064a \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0648\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645. \u064a\u0645\u0643\u0646\u0643 \u062a\u0634\u063a\u064a\u0644\u0647\u0627 \u0628\u0623\u0645\u0627\u0646 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0631\u062d\u0644\u0627\u062a \u062a\u062d\u0643\u0645 \u0642\u064a\u0627\u0633\u064a\u0629 \u0623\u0648 \u0648\u062d\u062f\u0627\u062a \u062a\u062d\u0643\u0645 \u0645\u0646\u0637\u0642\u064a\u0629 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0628\u0631\u0645\u062c\u0629 (PLC).<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u062a\u062d\u0642\u0642 \u062f\u0627\u0626\u0645\u064b\u0627 \u0645\u0646 \u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0642\u0628\u0644 \u0627\u0644\u062a\u062b\u0628\u064a\u062a. \u0642\u062f \u064a\u0624\u062f\u064a \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u062e\u0627\u0637\u0626 \u0625\u0644\u0649 \u062a\u0644\u0641 \u0627\u0644\u062c\u0647\u0627\u0632 \u0623\u0648 \u062d\u062f\u0648\u062b \u062e\u0644\u0644 \u0641\u064a \u0639\u0645\u0644\u0647.<\/p>\n<\/blockquote>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u062e\u062a\u064a\u0627\u0631 \u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0646\u0627\u0621\u064b \u0639\u0644\u0649 \u062a\u0635\u0645\u064a\u0645 \u0646\u0638\u0627\u0645\u0643 \u0648\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629. \u062a\u0639\u062a\u0628\u0631 \u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0623\u0643\u062b\u0631 \u0623\u0645\u0627\u0646\u064b\u0627 \u0644\u0644\u0645\u0648\u0638\u0641\u064a\u0646 \u0648\u0623\u0633\u0647\u0644 \u0641\u064a \u0627\u0644\u0625\u062f\u0627\u0631\u0629 \u0641\u064a \u063a\u0631\u0641 \u0627\u0644\u062a\u062d\u0643\u0645. \u0642\u062f \u062a\u0643\u0648\u0646 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0636\u0631\u0648\u0631\u064a\u0629 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u062b\u0642\u064a\u0644\u060c \u062e\u0627\u0635\u0629 \u0641\u064a VCBs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-and-endurance\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u062d\u0645\u0644<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"overcurrent-protection\">\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f<\/h3>\n\n\n\n<p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062d\u0645\u0627\u064a\u0629 \u0646\u0638\u0627\u0645\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f. \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062a\u0633\u0628\u0628 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f \u0641\u064a \u062a\u0644\u0641 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0648\u0642\u0648\u0639 \u062d\u0631\u0627\u0626\u0642. \u064a\u0648\u0641\u0631 \u0644\u0643 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u062d\u0645\u0627\u064a\u0629 \u0642\u0648\u064a\u0629 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f. \u064a\u0645\u0643\u0646\u0647 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0639\u0627\u062f\u064a\u0629 \u0648\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u062e\u0637\u064a\u0631\u0629. \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u0648\u062b\u0648\u0642 \u0641\u064a \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0639\u0646\u062f\u0645\u0627 \u064a\u0635\u0628\u062d \u0627\u0644\u062a\u064a\u0627\u0631 \u0645\u0631\u062a\u0641\u0639\u064b\u0627 \u062c\u062f\u064b\u0627.<\/p>\n\n\n\n<p>A <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0645\u0648\u0635\u0644 \u0641\u0631\u0627\u063a<\/a> \u064a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0645\u062e\u062a\u0644\u0641. \u064a\u0645\u0643\u0646\u0647 \u062a\u0628\u062f\u064a\u0644 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0639\u0627\u062f\u064a\u0629\u060c \u0648\u0644\u0643\u0646\u0647 \u0644\u0627 \u064a\u0645\u0643\u0646\u0647 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0628\u0645\u0641\u0631\u062f\u0647. \u064a\u062c\u0628 \u0625\u0636\u0627\u0641\u0629 \u0623\u062c\u0647\u0632\u0629 \u0625\u0636\u0627\u0641\u064a\u0629\u060c \u0645\u062b\u0644 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0623\u0648 \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a\u060c \u0644\u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0639\u0646\u062f \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0648\u0635\u0644.<\/p>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u064a\u0648\u0636\u062d \u0627\u0644\u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u064a\u0632\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u0635\u0644 \u0641\u0631\u0627\u063a\u064a (VC)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645\u060c \u064a\u0645\u0643\u0646\u0647 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062d\u0645\u0644\u064a\u0629 \u0648\u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062d\u062f\u0648\u062f\u060c \u064a\u062a\u0637\u0644\u0628 \u0623\u062c\u0647\u0632\u0629 \u0625\u0636\u0627\u0641\u064a\u0629 \u0644\u0644\u062d\u0645\u0627\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u062f\u0631\u0629 \u0642\u0637\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629\u060c \u0645\u0635\u0645\u0645\u0629 \u0644\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0639\u0637\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636\u0629\u060c \u063a\u064a\u0631 \u0645\u0635\u0645\u0645\u0629 \u0644\u0642\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0632\u0627\u0626\u062f\u060c \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629\u060c \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0627\u0644\u062a\u062f\u0627\u062e\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0642\u062a\u0635\u0631 \u0639\u0644\u0649 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u0642\u0637<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u062e\u062a\u0631 VCB \u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u062d\u0645\u0627\u064a\u0629 \u0643\u0627\u0645\u0644\u0629 \u0645\u0646 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0632\u0627\u0626\u062f \u0648\u0627\u0644\u0623\u0639\u0637\u0627\u0644. \u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0648\u0635\u0644\u064b\u0627 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0628\u0633\u064a\u0637\u060c \u0648\u0644\u0643\u0646 \u0623\u0636\u0641 \u062f\u0627\u0626\u0645\u064b\u0627 \u062d\u0645\u0627\u064a\u0629 \u0625\u0636\u0627\u0641\u064a\u0629.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"short-circuit-capability\">\u0642\u062f\u0631\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629<\/h3>\n\n\n\n<p>\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0641\u064a \u062a\u062f\u0641\u0642 \u062a\u064a\u0627\u0631\u0627\u062a \u0636\u062e\u0645\u0629 \u0641\u064a \u0646\u0638\u0627\u0645\u0643. \u0623\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u062c\u0647\u0627\u0632 \u064a\u0645\u0643\u0646\u0647 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0647\u0630\u0647 \u0627\u0644\u0623\u062d\u062f\u0627\u062b \u0627\u0644\u062e\u0637\u064a\u0631\u0629. \u062a\u0645 \u062a\u0635\u0645\u064a\u0645 VCB \u0644\u0647\u0630\u0627 \u0627\u0644\u063a\u0631\u0636. \u064a\u0645\u0643\u0646\u0647 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u062c\u062f\u064b\u0627 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0627\u0644\u0627\u0633\u062a\u0645\u0631\u0627\u0631 \u0641\u064a \u0627\u0644\u0639\u0645\u0644 \u0628\u0623\u0645\u0627\u0646 \u0628\u0639\u062f \u0627\u0644\u062d\u062f\u062b. \u0633\u062a\u0631\u0649 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0645\u062b\u0644 Icu (\u062a\u064a\u0627\u0631 \u0642\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a) \u0648 Ics (\u062a\u064a\u0627\u0631 \u0642\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0642\u0646\u0646) \u0639\u0644\u0649 VCBs. \u062a\u062e\u0628\u0631\u0643 \u0647\u0630\u0647 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0628\u0643\u0645\u064a\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646 \u0644\u0644\u0642\u0627\u0637\u0639 \u0625\u064a\u0642\u0627\u0641\u0647\u0627 \u062f\u0648\u0646 \u062a\u0644\u0641.<\/p>\n\n\n\n<p>\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0644\u0627 \u062a\u062a\u0645\u062a\u0639 \u0628\u0647\u0630\u0647 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a. \u0641\u0647\u064a \u0644\u0627 \u062a\u0633\u062a\u0637\u064a\u0639 \u0642\u0637\u0639 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629. \u064a\u0645\u0643\u0646\u0647\u0627 \u0641\u0642\u0637 \u062d\u0645\u0644 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0644\u0641\u062a\u0631\u0629 \u0648\u062c\u064a\u0632\u0629\u060c \u0648\u0644\u0643\u0646\u0647\u0627 \u0644\u0627 \u062a\u0633\u062a\u0637\u064a\u0639 \u0642\u0637\u0639\u0647. \u064a\u062c\u0628 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 VCB \u0623\u0648 \u0645\u0635\u0647\u0631 \u0644\u0642\u0637\u0639 \u0627\u0644\u0639\u0637\u0644.<\/p>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u0645\u0642\u0627\u0631\u0646\u0629:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u064a\u0632\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 (VCBs)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a (LBS)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Icu (\u062a\u064a\u0627\u0631 \u0642\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u0648\u0649)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u063a\u064a\u0631 \u0645\u062a\u0648\u0641\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Ics (\u062a\u064a\u0627\u0631 \u0642\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631 \u0627\u0644\u0645\u0642\u0646\u0646)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u063a\u064a\u0631 \u0645\u062a\u0648\u0641\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Icm (\u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0625\u0646\u062a\u0627\u062c\u064a\u0629)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u063a\u064a\u0631 \u0645\u062a\u0648\u0641\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Icw (\u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0644\u0641\u062a\u0631\u0629 \u0642\u0635\u064a\u0631\u0629)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u063a\u064a\u0631 \u0645\u062a\u0648\u0641\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Ipk (\u062a\u064a\u0627\u0631 \u0627\u0644\u0630\u0631\u0648\u0629 \u0627\u0644\u0645\u0642\u0627\u0648\u0645)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u063a\u064a\u0631 \u0645\u062a\u0648\u0641\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0627\u0633\u062a\u062e\u062f\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 VCB \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629. \u0644\u0627 \u064a\u0645\u0643\u0646 \u0644\u0644\u0645\u0648\u0635\u0644 \u0648\u062d\u062f\u0647 \u062d\u0645\u0627\u064a\u0629 \u0646\u0638\u0627\u0645\u0643 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mechanical-endurance\">\u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/h3>\n\n\n\n<p>\u062a\u0631\u064a\u062f \u0623\u0646 \u062a\u062f\u0648\u0645 \u0645\u0639\u062f\u0627\u062a\u0643 \u0644\u0641\u062a\u0631\u0629 \u0637\u0648\u064a\u0644\u0629. \u062a\u062e\u0628\u0631\u0643 \u0627\u0644\u0645\u062a\u0627\u0646\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0628\u0639\u062f\u062f \u0627\u0644\u0645\u0631\u0627\u062a \u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646\u0643 \u0641\u064a\u0647\u0627 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u062c\u0647\u0627\u0632 \u0642\u0628\u0644 \u0623\u0646 \u064a\u062a\u0644\u0641. \u064a\u0645\u0643\u0646 \u0644\u0645\u0639\u0638\u0645 VCBs \u0645\u0646 \u0641\u0626\u0629 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 10,000 \u0625\u0644\u0649 20,000 \u0639\u0645\u0644\u064a\u0629. \u064a\u0645\u0643\u0646 \u0644\u0628\u0639\u0636 VCBs \u0627\u0644\u062e\u0627\u0635\u0629 \u0623\u0646 \u062a\u062f\u0648\u0645 \u0644\u0640 100,000 \u0639\u0645\u0644\u064a\u0629 \u0623\u0648 \u0623\u0643\u062b\u0631. \u0647\u0630\u0627 \u064a\u0639\u0646\u064a \u0623\u0646\u0647 \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u0648\u062b\u0648\u0642 \u0628\u0640 VCB \u0644\u0633\u0646\u0648\u0627\u062a \u0639\u062f\u064a\u062f\u0629 \u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0633\u062a\u062e\u062f\u0645\u0647 \u0644\u0644\u063a\u0631\u0636 \u0627\u0644\u0635\u062d\u064a\u062d.<\/p>\n\n\n\n<p>\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u062a\u062a\u0645\u062a\u0639 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0628\u0642\u062f\u0631\u0629 \u062a\u062d\u0645\u0644 \u0623\u0639\u0644\u0649. \u0641\u0647\u064a \u0645\u0635\u0645\u0645\u0629 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0648\u064a\u0645\u0643\u0646\u0647\u0627 \u0627\u0644\u0639\u0645\u0644 \u0645\u0626\u0627\u062a \u0627\u0644\u0622\u0644\u0627\u0641 \u0623\u0648 \u062d\u062a\u0649 \u0645\u0644\u0627\u064a\u064a\u0646 \u0627\u0644\u0645\u0631\u0627\u062a. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644\u0647\u0627 \u0645\u062b\u0627\u0644\u064a\u0629 \u0644\u0644\u0623\u0639\u0645\u0627\u0644 \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0625\u064a\u0642\u0627\u0641\u0647\u0627 \u0639\u062f\u0629 \u0645\u0631\u0627\u062a \u0643\u0644 \u064a\u0648\u0645.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>VCBs: 10,000 \u0625\u0644\u0649 20,000 \u0639\u0645\u0644\u064a\u0629 (\u0642\u064a\u0627\u0633\u064a\u0629)\u060c \u062d\u062a\u0649 100,000 (\u0623\u0646\u0648\u0627\u0639 \u062e\u0627\u0635\u0629)<\/p><\/li>\n\n\n\n<li><p>\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a: \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0635\u0644 \u0625\u0644\u0649 \u0645\u0626\u0627\u062a \u0627\u0644\u0622\u0644\u0627\u0641 \u0625\u0644\u0649 \u0645\u0644\u0627\u064a\u064a\u0646 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u060c \u0641\u0627\u062e\u062a\u0631 \u0645\u0648\u0635\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629 \u0627\u0644\u0639\u0631\u0636\u064a\u0629\u060c \u064a\u0648\u0641\u0631 \u0644\u0643 VCB \u0639\u0645\u0631\u064b\u0627 \u0637\u0648\u064a\u0644\u0627\u064b \u0648\u062d\u0645\u0627\u064a\u0629 \u0642\u0648\u064a\u0629.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"maintenance-needs\">\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/h3>\n\n\n\n<p>\u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u0641\u0643\u064a\u0631 \u0641\u064a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0639\u0646\u062f \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0628\u064a\u0646 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0648\u0627\u0644\u0645\u0648\u0635\u0644. \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062c\u064a\u062f\u0629 \u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0623\u0645\u0627\u0646 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0646\u0638\u0627\u0645\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0644\u0643\u0644 \u062c\u0647\u0627\u0632 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0645\u062e\u062a\u0644\u0641\u0629\u060c \u0644\u0630\u0627 \u0639\u0644\u064a\u0643 \u062a\u062e\u0637\u064a\u0637 \u062c\u062f\u0648\u0644\u0643 \u0627\u0644\u0632\u0645\u0646\u064a \u0648\u0645\u0648\u0627\u0631\u062f\u0643.<\/p>\n\n\n\n<p>\u064a\u062a\u0645\u064a\u0632 VCB \u0628\u062a\u0635\u0645\u064a\u0645\u0647 \u0627\u0644\u0645\u062a\u064a\u0646. \u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647 \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629\u060c \u0648\u0644\u0643\u0646\u0647 \u0644\u0627 \u064a\u062a\u0637\u0644\u0628 \u0635\u064a\u0627\u0646\u0629 \u0645\u062a\u0643\u0631\u0631\u0629. \u0644\u0627 \u064a\u062a\u0622\u0643\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u0641\u0631\u0627\u063a \u062f\u0627\u062e\u0644 VCB \u0628\u0633\u0631\u0639\u0629. \u064a\u0645\u0643\u0646\u0643 \u062a\u0648\u0642\u0639 \u0641\u062a\u0631\u0627\u062a \u0635\u064a\u0627\u0646\u0629 \u0637\u0648\u064a\u0644\u0629\u060c \u0642\u062f \u062a\u0635\u0644 \u0623\u062d\u064a\u0627\u0646\u064b\u0627 \u0625\u0644\u0649 \u0639\u062f\u0629 \u0633\u0646\u0648\u0627\u062a \u0628\u064a\u0646 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0641\u062d\u0635 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0648\u062a\u0646\u0638\u064a\u0641 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0639\u0632\u0644. \u062a\u0648\u0635\u064a \u0645\u0639\u0638\u0645 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0628\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0643\u0627\u0645\u0644 \u0643\u0644 1 \u0625\u0644\u0649 3 \u0633\u0646\u0648\u0627\u062a. \u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0633\u062a\u062e\u062f\u0645 VCB \u0641\u064a \u0628\u064a\u0626\u0627\u062a \u0642\u0627\u0633\u064a\u0629\u060c \u0641\u0642\u062f \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0641\u062d\u0635\u0647 \u0628\u0634\u0643\u0644 \u0623\u0643\u062b\u0631 \u062a\u0643\u0631\u0627\u0631\u064b\u0627.<\/p>\n\n\n\n<p>\u064a\u0639\u0645\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0628\u0634\u0643\u0644 \u0645\u062e\u062a\u0644\u0641. \u064a\u062a\u0645 \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u060c \u0644\u0630\u0627 \u0641\u0647\u0648 \u064a\u062a\u0639\u0631\u0636 \u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u062a\u0622\u0643\u0644 \u0648\u0627\u0644\u062a\u0644\u0641. \u0642\u062f \u062a\u062a\u0622\u0643\u0644 \u0623\u0648 \u062a\u062a\u0644\u0641 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0628\u0639\u062f \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a. \u064a\u062c\u0628 \u0641\u062d\u0635 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0628\u0634\u0643\u0644 \u0645\u062a\u0643\u0631\u0631\u060c \u062e\u0627\u0635\u0629 \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0645\u0632\u062f\u062d\u0645\u0629. \u0642\u062f \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062a\u0646\u0638\u064a\u0641 \u0623\u0648 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0643\u0644 \u0628\u0636\u0639\u0629 \u0623\u0634\u0647\u0631. \u062a\u062d\u062a\u0627\u062c \u0623\u064a\u0636\u064b\u0627 \u0625\u0644\u0649 \u0641\u062d\u0635 \u0627\u0644\u0645\u0644\u0641 \u0648\u0627\u0644\u0632\u0646\u0628\u0631\u0643\u0627\u062a \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u0639\u0628.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0642\u0645 \u0628\u0625\u0639\u062f\u0627\u062f \u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0644\u0643\u0644 \u062c\u0647\u0627\u0632. \u062a\u0633\u0627\u0639\u062f\u0643 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0645\u0646\u062a\u0638\u0645\u0629 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0645\u0628\u0643\u0631\u064b\u0627 \u0648\u062a\u062c\u0646\u0628 \u0627\u0644\u062a\u0648\u0642\u0641 \u0639\u0646 \u0627\u0644\u0639\u0645\u0644 \u0627\u0644\u0630\u064a \u064a\u0643\u0644\u0641\u0643 \u0627\u0644\u0643\u062b\u064a\u0631.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u0644\u0645\u0633\u0627\u0639\u062f\u062a\u0643 \u0641\u064a \u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0646\u0648\u0639 \u0627\u0644\u062c\u0647\u0627\u0632<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u062a\u0643\u0631\u0627\u0631 \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u062a\u0648\u0642\u0639<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636\u0629 (1-3 \u0633\u0646\u0648\u0627\u062a)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0641\u062d\u0635 \u0648\u0627\u0644\u062a\u0646\u0638\u064a\u0641 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u062a\u0634\u062d\u064a\u0645<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10-20 \u0633\u0646\u0629 \u0623\u0648 \u0623\u0643\u062b\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u0635\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629 (3-12 \u0634\u0647\u0631\u064b\u0627)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0641\u062d\u0635 \u0648\u062a\u0646\u0638\u064a\u0641 \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>5-10 \u0633\u0646\u0648\u0627\u062a<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u062d\u062a\u0641\u0638 \u0628\u0642\u0637\u0639 \u063a\u064a\u0627\u0631 \u062c\u0627\u0647\u0632\u0629 \u0644\u0643\u0644\u0627 \u0627\u0644\u062c\u0647\u0627\u0632\u064a\u0646. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0641\u0627\u062a\u064a\u062d VCB\u060c \u0642\u062f \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0646\u0648\u0627\u0628\u0636 \u0623\u0648 \u0645\u0648\u0627\u062f \u062a\u0634\u062d\u064a\u0645 \u0628\u062f\u064a\u0644\u0629. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u0648\u0635\u0644\u0627\u062a\u060c \u064a\u062c\u0628 \u0623\u0646 \u062a\u062d\u062a\u0641\u0638 \u0628\u0645\u062e\u0632\u0648\u0646 \u0625\u0636\u0627\u0641\u064a \u0645\u0646 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0648\u0627\u0644\u0645\u0644\u0641\u0627\u062a. \u064a\u0645\u0643\u0646\u0643 \u062a\u0642\u0644\u064a\u0644 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0625\u0630\u0627 \u0642\u0645\u062a \u0628\u0627\u0644\u062a\u062d\u0636\u064a\u0631 \u0645\u0633\u0628\u0642\u064b\u0627.<\/p>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u062a\u0628\u0627\u0639 \u0625\u0631\u0634\u0627\u062f\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0641\u064a\u0645\u0627 \u064a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0635\u064a\u0627\u0646\u0629. \u0644\u0643\u0644 \u0637\u0631\u0627\u0632 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u062e\u0627\u0635\u0629. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u062f\u0644\u064a\u0644 \u0648\u062a\u062f\u0631\u064a\u0628 \u0645\u0648\u0638\u0641\u064a\u0643. \u062a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u062c\u064a\u062f\u0629 \u0639\u0644\u0649 \u062a\u062a\u0628\u0639 \u062a\u0648\u0627\u0631\u064a\u062e \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0627\u0641\u062d\u0635 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0639\u0644\u0627\u0645\u0627\u062a \u0627\u062d\u062a\u0631\u0627\u0642 \u0623\u0648 \u062a\u0622\u0643\u0644.<\/p><\/li>\n\n\n\n<li><p>\u0642\u0645 \u0628\u062a\u0646\u0638\u064a\u0641 \u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u0623\u0648\u0633\u0627\u062e \u0645\u0646 \u0627\u0644\u0639\u0644\u0628\u0629.<\/p><\/li>\n\n\n\n<li><p>\u0627\u062e\u062a\u0628\u0631 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0644\u0641 \u0648\u0627\u0644\u0632\u0646\u0628\u0631\u0643\u0627\u062a.<\/p><\/li>\n\n\n\n<li><p>\u0642\u0645 \u0628\u062a\u0632\u064a\u064a\u062a \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u062a\u062d\u0631\u0643\u0629 \u062d\u0633\u0628 \u0627\u0644\u062d\u0627\u062c\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0625\u0630\u0627 \u062a\u062c\u0627\u0647\u0644\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u060c \u0641\u0625\u0646\u0643 \u062a\u062e\u0627\u0637\u0631 \u0628\u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0641\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0645\u062e\u0627\u0637\u0631 \u062a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0633\u0644\u0627\u0645\u0629. \u064a\u0645\u0643\u0646\u0643 \u062a\u062c\u0646\u0628 \u0645\u0639\u0638\u0645 \u0627\u0644\u0645\u0634\u0627\u0643\u0644 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0639\u0646\u0627\u064a\u0629 \u0627\u0644\u0645\u0646\u062a\u0638\u0645\u0629. \u064a\u0645\u0643\u0646\u0643 \u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u0645\u0627\u0644 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u064a\u0631 \u0646\u0638\u0627\u0645\u0643 \u0628\u0633\u0644\u0627\u0633\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062c\u062f\u0648\u0644\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u062e\u0644\u0627\u0644 \u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u062e\u0637\u0637 \u0644\u0647\u0627. \u0641\u0647\u0630\u0627 \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0623\u0645\u0627\u0646 \u0646\u0638\u0627\u0645\u0643 \u0648\u064a\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u064a \u0627\u0646\u0642\u0637\u0627\u0639\u0627\u062a.<\/p>\n<\/blockquote>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u062c\u0639\u0644 \u0646\u0638\u0627\u0645\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u0643\u062b\u0631 \u0623\u0645\u0627\u0646\u064b\u0627 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0639\u0646\u062f\u0645\u0627 \u062a\u0647\u062a\u0645 \u0628\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629. \u0641\u0623\u0646\u062a \u0628\u0630\u0644\u0643 \u062a\u062d\u0645\u064a \u0627\u0633\u062a\u062b\u0645\u0627\u0631\u0643 \u0648\u062a\u062f\u0639\u0645 \u0633\u064a\u0631 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0628\u0633\u0644\u0627\u0633\u0629.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"applications-and-use-cases\">\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0648\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57.webp\" alt=\"\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0648\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645\" class=\"wp-image-1536\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0635\u062f\u0631 \u0627\u0644\u0635\u0648\u0631\u0629: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/unsplash.com\">unsplash<\/a><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-applications\">\u062a\u0637\u0628\u064a\u0642\u0627\u062a VCB<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"power-distribution\">\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629<\/h4>\n\n\n\n<p>\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0631\u0649 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0641\u064a \u0634\u0628\u0643\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629. \u0641\u0647\u064a \u062a\u062d\u0645\u064a \u0627\u0644\u0645\u063a\u0630\u064a\u0627\u062a \u0648\u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0645\u062c\u0645\u0648\u0639\u0627\u062a \u0627\u0644\u0645\u0643\u062b\u0641\u0627\u062a \u0641\u064a \u0643\u0644 \u0645\u0646 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062d\u0636\u0631\u064a\u0629 \u0648\u0627\u0644\u0631\u064a\u0641\u064a\u0629. \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u062a\u062f\u0641\u0642 \u0627\u0644\u0637\u0627\u0642\u0629 \u0628\u0623\u0645\u0627\u0646 \u0648\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u0636\u0631\u0627\u0631 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0623\u0639\u0637\u0627\u0644. \u0641\u064a \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629\u060c \u062a\u0633\u062a\u062e\u062f\u0645 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0648\u0627\u0644\u0623\u0641\u0631\u0627\u0646 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062b\u0642\u064a\u0644\u0629 \u0627\u0644\u0623\u062e\u0631\u0649. \u062a\u0644\u0639\u0628 \u0647\u0630\u0647 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0623\u064a\u0636\u064b\u0627 \u062f\u0648\u0631\u064b\u0627 \u0631\u0626\u064a\u0633\u064a\u064b\u0627 \u0641\u064a \u0643\u0647\u0631\u0628\u0629 \u0627\u0644\u0633\u0643\u0643 \u0627\u0644\u062d\u062f\u064a\u062f\u064a\u0629\u060c \u062d\u064a\u062b \u062a\u0636\u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0645\u0646 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642 \u0644\u0623\u0646\u0638\u0645\u0629 \u0637\u0627\u0642\u0629 \u0627\u0644\u062c\u0631.<\/p>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u064a\u0648\u0636\u062d \u0633\u064a\u0646\u0627\u0631\u064a\u0648\u0647\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0644\u0640 VCBs:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0633\u064a\u0646\u0627\u0631\u064a\u0648 \u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0648\u0635\u0641<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0634\u0628\u0643\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062d\u0645\u064a \u0627\u0644\u0645\u063a\u0630\u064a\u0627\u062a \u0648\u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0645\u062c\u0645\u0648\u0639\u0627\u062a \u0627\u0644\u0645\u0643\u062b\u0641\u0627\u062a \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u0648\u0632\u064a\u0639<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062d\u0645\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0648\u0627\u0644\u0623\u0641\u0631\u0627\u0646 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062b\u0642\u064a\u0644\u0629 \u0641\u064a \u0627\u0644\u0645\u0635\u0627\u0646\u0639<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0643\u0647\u0631\u0628\u0629 \u0627\u0644\u0633\u0643\u0643 \u0627\u0644\u062d\u062f\u064a\u062f\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0636\u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0648\u062b\u0648\u0642 \u0644\u0623\u0646\u0638\u0645\u0629 \u0637\u0627\u0642\u0629 \u0627\u0644\u062c\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0648\u0644\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0645\u0646 \u0627\u0644\u0631\u064a\u0627\u062d<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0648\u0641\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u062a\u0648\u0631\u0628\u064a\u0646\u0627\u062a \u0627\u0644\u0631\u064a\u0627\u062d<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0635\u0639\u0628\u0629 \u0628\u0623\u0645\u0627\u0646 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0639\u0627\u0644\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0627\u0644\u0641\u0631\u0639\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062e\u0637\u0648\u0637 \u0648\u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0641\u064a \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u062a\u0648\u0641\u0631 \u0644\u0643 VCBs \u062d\u0645\u0627\u064a\u0629 \u0645\u0648\u062b\u0648\u0642\u0629 \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0642\u0627\u0633\u064a\u0629 \u0648\u0630\u0627\u062a \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0639\u0627\u0644\u064a\u0629.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"high-voltage-systems\">\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a<\/h4>\n\n\n\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 VCBs \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0644\u0623\u0646\u0647\u0627 \u0642\u0627\u062f\u0631\u0629 \u0639\u0644\u0649 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0628\u0633\u0631\u0639\u0629. \u0648\u062a\u0634\u0645\u0644 \u0647\u0630\u0647 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0645\u0646 \u0627\u0644\u0631\u064a\u0627\u062d\u060c \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u060c \u0648\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0627\u0644\u0641\u0631\u0639\u064a\u0629. \u0641\u064a \u0645\u0632\u0627\u0631\u0639 \u0627\u0644\u0631\u064a\u0627\u062d\u060c \u062a\u062d\u0645\u064a VCBs \u0627\u0644\u062a\u0648\u0631\u0628\u064a\u0646\u0627\u062a \u0648\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0635\u064a\u0627\u0646\u0629. \u0641\u064a \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u060c \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 VCBs \u0645\u0646 \u0623\u062c\u0644 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0641\u064a \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0635\u0639\u0628\u0629. \u062a\u0639\u062a\u0645\u062f \u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0639\u0644\u0649 VCBs \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062e\u0637\u0648\u0637 \u0648\u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"contactor-applications\">\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u0644\u0627\u0645\u0633<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"motor-control\">\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643<\/h4>\n\n\n\n<p>\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0644\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a. \u0641\u0647\u064a \u062a\u062a\u064a\u062d \u0644\u0643 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0648\u0625\u064a\u0642\u0627\u0641\u0647\u0627 \u062a\u0644\u0642\u0627\u0626\u064a\u064b\u0627 \u0641\u064a \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0635\u0646\u064a\u0639. \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u062a\u0643\u064a\u064a\u0641 \u0627\u0644\u0647\u0648\u0627\u0621 (HVAC)\u060c \u062a\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0641\u064a \u0627\u0644\u0636\u0648\u0627\u063a\u0637 \u0648\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0646\u0627\u0641\u064a\u062e \u0648\u0627\u0644\u0645\u0631\u0627\u0648\u062d. \u0643\u0645\u0627 \u062a\u0633\u062a\u062e\u062f\u0645\u0647\u0627 \u0623\u064a\u0636\u064b\u0627 \u0641\u064a \u0627\u0644\u0645\u0636\u062e\u0627\u062a \u0648\u0623\u062d\u0632\u0645\u0629 \u0627\u0644\u0646\u0642\u0644 \u0648\u0627\u0644\u062e\u0644\u0627\u0637\u0627\u062a. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0636\u0631\u0648\u0631\u064a\u0629 \u0644\u0644\u0623\u062a\u0645\u062a\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0635\u0646\u0627\u0639\u064a.<\/p>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u0628\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629 \u0644\u0644\u0645\u0648\u0635\u0644\u0627\u062a:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0646\u0648\u0639 \u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u062d\u0627\u0644\u0627\u062a \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u062d\u062f\u062f\u0629<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0628\u062f\u0621\/\u0625\u064a\u0642\u0627\u0641 \u0622\u0644\u064a \u0641\u064a \u0627\u0644\u062a\u0635\u0646\u064a\u0639<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u062a\u0643\u064a\u064a\u0641 \u0627\u0644\u0647\u0648\u0627\u0621<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0636\u0648\u0627\u063a\u0637 \u0648\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0646\u0627\u0641\u064a\u062e \u0648\u0627\u0644\u0645\u0631\u0627\u0648\u062d<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0626\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u0644\u0623\u0641\u0631\u0627\u0646 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0627\u0644\u063a\u0644\u0627\u064a\u0627\u062a<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0646\u0633\u0642 \u0641\u064a \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0625\u0636\u0627\u0621\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0636\u062e\u0627\u062a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0645\u064a\u0627\u0647 \u0648\u0627\u0644\u062c\u0631\u0639\u0627\u062a \u0627\u0644\u0643\u064a\u0645\u064a\u0627\u0626\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0636\u0648\u0627\u063a\u0637<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0648\u0636\u063a\u0637 \u0627\u0644\u0647\u0648\u0627\u0621<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u062d\u0632\u0645\u0629 \u0627\u0644\u0646\u0642\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062d\u0631\u0643\u0629 \u0641\u064a \u062e\u0637\u0648\u0637 \u0627\u0644\u062a\u0639\u0628\u0626\u0629 \u0648\u0627\u0644\u062a\u063a\u0644\u064a\u0641 \u0648\u0627\u0644\u062a\u062c\u0645\u064a\u0639<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062e\u0644\u0627\u0637\u0627\u062a \u0648\u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u062c\u0647\u064a\u0632 \u0627\u0644\u0623\u063a\u0630\u064a\u0629 \u0648\u0627\u0644\u0645\u0632\u062c \u0627\u0644\u0635\u0646\u0627\u0639\u064a<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u064a\u0645\u0643\u0646\u0643 \u0641\u0635\u0644 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0623\u0645\u0627\u0646 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"frequent-switching\">\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631<\/h4>\n\n\n\n<p>\u062a\u062e\u062a\u0627\u0631 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0639\u0646\u062f\u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631. \u0641\u0647\u064a \u062a\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0622\u0644\u064a\u0629 \u0648\u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629\u060c \u0645\u062b\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062c\u062f\u0648\u0644 \u0641\u064a \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0623\u0648 \u062a\u0634\u063a\u064a\u0644 \u0633\u064a\u0648\u0631 \u0627\u0644\u0646\u0642\u0644. \u064a\u0645\u0643\u0646\u0643 \u062a\u0648\u0633\u064a\u0639 \u0646\u0638\u0627\u0645\u0643 \u0628\u0633\u0647\u0648\u0644\u0629 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a. \u062a\u062f\u0639\u0645 \u0647\u0630\u0647 \u0627\u0644\u0645\u0631\u0648\u0646\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0637\u0648\u064a\u0631.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u062d\u0645\u064a \u0645\u0648\u0635\u0644\u0627\u062a \u0628\u062f\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u0628\u062f\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u062d\u0643\u0645 \u0645\u0648\u0635\u0644\u0627\u062a HVAC \u0641\u064a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0639\u0646 \u0637\u0631\u064a\u0642 \u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0636\u0648\u0627\u063a\u0637 \u0648\u0627\u0644\u0645\u0631\u0627\u0648\u062d.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u064a\u062d \u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062c\u062f\u0648\u0644 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0627\u0644\u0643\u0628\u064a\u0631\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"selection-criteria\">\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0636\u0639 \u0641\u064a \u0627\u0639\u062a\u0628\u0627\u0631\u0643 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0646\u0638\u0627\u0645\u0643 \u0642\u0628\u0644 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644. \u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062e\u0627\u0637\u0626\u0629 \u0648\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f\u060c \u0641\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u062e\u062a\u064a\u0627\u0631 VCB. \u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0648\u0627\u0644\u0623\u062a\u0645\u062a\u0629\u060c \u0641\u0625\u0646 \u0627\u0644\u0645\u0648\u0635\u0644 \u0647\u0648 \u0627\u0644\u062e\u064a\u0627\u0631 \u0627\u0644\u0623\u0641\u0636\u0644. \u0641\u0643\u0631 \u0641\u064a \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u062a\u0631\u062f\u062f \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629. \u064a\u0635\u0628\u062d \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0648\u0627\u0636\u062d\u064b\u0627 \u0639\u0646\u062f\u0645\u0627 \u062a\u062a\u0637\u0627\u0628\u0642 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0639 \u062a\u0637\u0628\u064a\u0642\u0643.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0646\u0635\u064a\u062d\u0629: \u0631\u0627\u062c\u0639 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0646\u0638\u0627\u0645\u0643 \u0645\u0646 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0627\u0644\u062a\u064a\u0627\u0631 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0642\u0628\u0644 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631 \u0627\u0644\u0646\u0647\u0627\u0626\u064a.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"technical-comparison-table\">\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u0641\u0646\u064a\u0629<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-vs-contactor-summary\">\u0645\u0644\u062e\u0635 VCB \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633<\/h3>\n\n\n\n<p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0645\u0642\u0627\u0631\u0646\u0629 \u0648\u0627\u0636\u062d\u0629 \u0639\u0646\u062f \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0628\u064a\u0646 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0648\u0627\u0644\u0645\u0648\u0635\u0644. \u064a\u0642\u062f\u0645 \u0644\u0643 \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0646\u0638\u0631\u0629 \u0634\u0627\u0645\u0644\u0629 \u0639\u0644\u0649 \u0623\u0647\u0645 \u0627\u0644\u0645\u064a\u0632\u0627\u062a. \u064a\u0633\u0627\u0639\u062f\u0643 \u0630\u0644\u0643 \u0639\u0644\u0649 \u0641\u0647\u0645 \u0643\u064a\u0641\u064a\u0629 \u0639\u0645\u0644 \u0643\u0644 \u062c\u0647\u0627\u0632 \u0648\u0645\u0627 \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0648\u0642\u0639\u0647 \u0641\u064a \u0646\u0638\u0627\u0645\u0643.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u064a\u0632\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u0635\u0644<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0639\u0632\u0644 \u0627\u0644\u062f\u0648\u0627\u0626\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u062d\u0645\u0644<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629 (\u062a\u062a\u062d\u0645\u0644 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0628\u064a\u0631\u0629)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636 (\u0644\u064a\u0633 \u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0639\u0637\u0644)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0642\u0648\u0633<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0639\u0645\u0631 \u0627\u062a\u0635\u0627\u0644 \u0637\u0648\u064a\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u064a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0635\u064a\u0627\u0646\u0629 \u0645\u062a\u0643\u0631\u0631\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u0644\u0642\u0637\u0639 \u0627\u0644\u062d\u0627\u0644\u064a<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0634\u0627\u0626\u0639\u060c \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0627\u062f\u0631\u060c \u062e\u0637\u0631 \u0645\u0646\u062e\u0641\u0636 \u0644\u062d\u062f\u0648\u062b \u062c\u0647\u062f \u0632\u0627\u0626\u062f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0642\u0648\u0633<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0633\u062a\u062e\u062f\u0645 \u0642\u0627\u0637\u0639 \u0641\u0631\u0627\u063a\u060c \u0625\u062e\u0645\u0627\u062f \u0633\u0631\u064a\u0639 \u0644\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0647\u0648\u0627\u0621 \u0623\u0648 \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u062a\u062d\u0643\u0645 \u0623\u0628\u0637\u0623 \u0641\u064a \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062a\u0648\u0633\u0637 \u0625\u0644\u0649 \u0645\u0631\u062a\u0641\u0639 (1 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0625\u0644\u0649 38 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636 \u0625\u0644\u0649 \u0645\u062a\u0648\u0633\u0637 (\u064a\u0635\u0644 \u0625\u0644\u0649 1.1 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0639\u0627\u062f\u0629)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u062a\u0631\u062f\u062f \u0627\u0644\u062a\u0628\u062f\u064a\u0644<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636 (\u062a\u0634\u063a\u064a\u0644 \u0639\u0631\u0636\u064a)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629 (\u0622\u0644\u0627\u0641 \u0627\u0644\u062f\u0648\u0631\u0627\u062a \u0641\u064a \u0627\u0644\u0633\u0627\u0639\u0629)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0622\u0644\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u0648\u0629 \u0623\u0642\u0644\u060c \u0622\u0644\u064a\u0629 \u0628\u0633\u064a\u0637\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0644\u0641 \u0645\u0633\u062a\u0647\u0644\u0643 \u0644\u0644\u0637\u0627\u0642\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645\u060c \u0645\u062f\u0645\u062c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0644\u0627\u060c \u064a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0623\u062c\u0647\u0632\u0629 \u0625\u0636\u0627\u0641\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0642\u062f\u0631\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0646\u0639\u0645\u060c \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0627\u062a \u0642\u0635\u0631 \u0627\u0644\u062f\u0648\u0627\u0626\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0644\u0627\u060c \u0644\u0627 \u064a\u0645\u0643\u0646 \u0643\u0633\u0631 \u0627\u0644\u0623\u0639\u0637\u0627\u0644<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10,000\u2013100,000 \u0639\u0645\u0644\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100,000\u20131,000,000+ \u0639\u0645\u0644\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636\u0629\u060c \u0641\u062a\u0631\u0627\u062a \u0637\u0648\u064a\u0644\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0641\u062d\u0648\u0635\u0627\u062a \u0645\u062a\u0643\u0631\u0631\u0629 \u0648\u0645\u0643\u062b\u0641\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u062d\u0629<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0635\u063a\u064a\u0631 \u0627\u0644\u062d\u062c\u0645\u060c \u064a\u0648\u0641\u0631 \u0645\u0633\u0627\u062d\u0629 \u0627\u0644\u0644\u0648\u062d\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0628\u0635\u0645\u0629 \u0623\u0643\u0628\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0648\u062b<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629\u060c \u0644\u0627 \u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0645\u0632\u0627\u0644\u0642 \u0642\u0648\u0633\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u062f\u0646\u0649\u060c \u064a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062a\u0646\u0638\u064a\u0641<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0639\u0644\u0649 (110 \u0641\u0648\u0644\u062a - 220 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631\/\u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0642\u0644 (24 \u0641\u0648\u0644\u062a \u2013 110 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f\/\u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a\u060c \u0627\u0644\u0623\u062a\u0645\u062a\u0629\u060c \u0627\u0644\u0625\u0636\u0627\u0621\u0629<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0647\u0630\u0627 \u0627\u0644\u062c\u062f\u0648\u0644 \u0644\u0645\u0637\u0627\u0628\u0642\u0629 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0644\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a\u0643. \u0627\u0646\u0638\u0631 \u0625\u0644\u0649 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0648\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0642\u0628\u0644 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"bullet-point-highlights\">\u0623\u0647\u0645 \u0627\u0644\u0646\u0642\u0627\u0637<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0633\u062a\u062e\u062f\u0645 VCB \u0639\u0646\u062f\u0645\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062d\u0645\u0627\u064a\u0629 \u0646\u0638\u0627\u0645\u0643 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0639\u0627\u0644\u064a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062e\u062a\u0627\u0631 \u0645\u0648\u0635\u0644\u064b\u0627 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0633\u0647\u0644 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0623\u0648 \u0627\u0644\u0623\u0636\u0648\u0627\u0621.<\/p><\/li>\n\n\n\n<li><p>\u062a\u0642\u0648\u0645 VCBs \u0628\u0642\u0637\u0639 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0628\u0633\u0631\u0639\u0629 \u0648\u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0645\u0639\u062f\u0627\u062a\u0643 \u0645\u0646 \u0627\u0644\u062a\u0644\u0641.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062a\u0639\u0627\u0645\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0639 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u062f\u0648\u0631\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u0625\u064a\u0642\u0627\u0641\u060c \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0628\u0633\u0628\u0628 \u062d\u062f\u0648\u062b \u0642\u0648\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p><\/li>\n\n\n\n<li><p>\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 VCBs \u0641\u064a \u062d\u062f\u0648\u062b \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0628\u0633\u0628\u0628 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u060c \u0644\u0630\u0627 \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0641\u062d\u0635 \u0646\u0638\u0627\u0645\u0643 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0645\u062e\u0627\u0637\u0631 \u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062c\u0647\u062f.<\/p><\/li>\n\n\n\n<li><p>\u0646\u0627\u062f\u0631\u0627\u064b \u0645\u0627 \u062a\u0633\u0628\u0628 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u062c\u064a\u062f \u0641\u064a \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0623\u062a\u0645\u062a\u0629.<\/p><\/li>\n\n\n\n<li><p>\u062a\u0648\u0641\u0631 VCBs \u0645\u0633\u0627\u062d\u0629 \u0648\u062a\u0642\u0627\u0648\u0645 \u0627\u0644\u063a\u0628\u0627\u0631 \u0623\u0648 \u0627\u0644\u062a\u0644\u0648\u062b \u0628\u0634\u0643\u0644 \u0623\u0641\u0636\u0644 \u0645\u0646 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0625\u0636\u0627\u0641\u0629 \u0623\u062c\u0647\u0632\u0629 \u062d\u0645\u0627\u064a\u0629 \u0625\u0636\u0627\u0641\u064a\u0629 \u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0648\u0635\u0644\u064b\u0627 \u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u062d\u0645\u0644.<\/p><\/li>\n\n\n\n<li><p>\u062a\u062f\u0648\u0645 VCBs \u0644\u0641\u062a\u0631\u0629 \u0623\u0637\u0648\u0644 \u0645\u0639 \u0635\u064a\u0627\u0646\u0629 \u0623\u0642\u0644\u060c \u0648\u0644\u0643\u0646 \u064a\u062c\u0628 \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647\u0627 \u0641\u0642\u0637 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629.<\/p><\/li>\n\n\n\n<li><p>\u062a\u0648\u0641\u0631 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0642\u062f\u0631\u0629 \u062a\u062d\u0645\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0648\u062a\u0646\u0627\u0633\u0628 \u0628\u0634\u0643\u0644 \u0623\u0641\u0636\u0644 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0631\u064a\u062f \u062d\u0645\u0627\u064a\u0629 \u0642\u0648\u064a\u0629 \u0648\u0635\u064a\u0627\u0646\u0629 \u0642\u0644\u064a\u0644\u0629\u060c \u0641\u0627\u062e\u062a\u0631 VCB. \u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u062a\u0628\u062f\u064a\u0644 \u0633\u0631\u064a\u0639 \u0648\u0645\u062a\u0643\u0631\u0631\u060c \u0641\u0625\u0646 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0647\u0648 \u062e\u064a\u0627\u0631\u0643 \u0627\u0644\u0623\u0641\u0636\u0644.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"choosing-the-right-device\">\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"decision-factors\">\u0639\u0648\u0627\u0645\u0644 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631<\/h3>\n\n\n\n<p>\u0639\u0646\u062f \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0628\u064a\u0646 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a (VCB) \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u060c \u064a\u062c\u0628 \u0645\u0631\u0627\u0639\u0627\u0629 \u0639\u062f\u0629 \u0639\u0648\u0627\u0645\u0644 \u0645\u0647\u0645\u0629. \u0644\u0643\u0644 \u0646\u0638\u0627\u0645 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0641\u0631\u064a\u062f\u0629\u060c \u0644\u0630\u0627 \u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0646\u0627\u0633\u0628 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0639 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0637\u0644\u0648\u0628. \u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u0623\u0647\u0645 \u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0645\u0631\u0627\u0639\u0627\u062a\u0647\u0627:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629<\/strong>: \u0623\u0646\u062a \u062a\u0631\u064a\u062f \u062c\u0647\u0627\u0632\u064b\u0627 \u064a\u0639\u0645\u0644 \u0641\u064a \u0643\u0644 \u0627\u0644\u0623\u0648\u0642\u0627\u062a. \u062a\u0648\u0641\u0631 \u0644\u0643 VCBs \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0628\u0641\u0636\u0644 \u062a\u0635\u0645\u064a\u0645\u0647\u0627 \u0627\u0644\u0642\u0648\u064a \u0648\u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a\u0647\u0627 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0644\u0644\u0635\u064a\u0627\u0646\u0629. \u0648\u0647\u0630\u0627 \u0623\u0645\u0631 \u0645\u0647\u0645 \u0644\u0644\u063a\u0627\u064a\u0629 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u062d\u064a\u062b \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639\u0627\u062a \u0641\u064a \u0645\u0634\u0627\u0643\u0644 \u0643\u0628\u064a\u0631\u0629.<\/p><\/li>\n\n\n\n<li><p><strong>\u0627\u0644\u0635\u062f\u0627\u0642\u0629 \u0627\u0644\u0628\u064a\u0626\u064a\u0629<\/strong>: \u062a\u0633\u062a\u062e\u062f\u0645 VCBs \u0627\u0644\u0641\u0631\u0627\u063a \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0623\u0648 \u0627\u0644\u0632\u064a\u0648\u062a. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644\u0647\u0627 \u062e\u064a\u0627\u0631\u0627\u064b \u0623\u0641\u0636\u0644 \u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0647\u062a\u0645 \u0628\u0627\u0644\u0628\u064a\u0626\u0629. \u0641\u0623\u0646\u062a \u062a\u062a\u062c\u0646\u0628 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u063a\u0627\u0632\u0627\u062a \u0627\u0644\u062f\u0641\u064a\u0626\u0629 \u0627\u0644\u0636\u0627\u0631\u0629.<\/p><\/li>\n\n\n\n<li><p><strong>\u062e\u0635\u0627\u0626\u0635 \u0627\u0644\u0623\u062f\u0627\u0621<\/strong>: \u062a\u0639\u0627\u0644\u062c \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f (VCB) \u0627\u0644\u0623\u0642\u0648\u0627\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0628\u0634\u0643\u0644 \u0623\u0641\u0636\u0644 \u0645\u0646 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0623\u062e\u0631\u0649. \u0641\u0647\u064a \u062a\u0637\u0641\u0626 \u0627\u0644\u0623\u0642\u0648\u0627\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0628\u0633\u0631\u0639\u0629 \u0648\u0623\u0645\u0627\u0646\u060c \u0645\u0645\u0627 \u064a\u062d\u0645\u064a \u0645\u0639\u062f\u0627\u062a\u0643.<\/p><\/li>\n\n\n\n<li><p><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646<\/strong>: \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646\u064a\u0646. \u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0639 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062d\u0645\u0644 \u0648\u0627\u0644\u062c\u0647\u062f \u0641\u064a \u0646\u0638\u0627\u0645\u0643.<\/p><\/li>\n\n\n\n<li><p><strong>\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0643\u0633\u0631<\/strong>: \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u062c\u0647\u0627\u0632 \u064a\u0645\u0643\u0646\u0647 \u0642\u0637\u0639 \u0623\u0639\u0644\u0649 \u062a\u064a\u0627\u0631 \u062e\u0637\u0623 \u0642\u062f \u064a\u0648\u0627\u062c\u0647\u0647 \u0646\u0638\u0627\u0645\u0643 \u0628\u0623\u0645\u0627\u0646.<\/p><\/li>\n\n\n\n<li><p><strong>\u0627\u0644\u0645\u062a\u0627\u0646\u0629 \u0648\u0633\u0647\u0648\u0644\u0629 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645<\/strong>: \u0627\u062e\u062a\u0631 \u062c\u0647\u0627\u0632\u064b\u0627 \u064a\u062f\u0648\u0645 \u0637\u0648\u064a\u0644\u0627\u064b \u0648\u064a\u0633\u0647\u0644 \u062a\u0634\u063a\u064a\u0644\u0647. \u0641\u0647\u0630\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644.<\/p><\/li>\n\n\n\n<li><p><strong>\u0645\u064a\u0632\u0627\u062a \u0630\u0643\u064a\u0629<\/strong>: \u064a\u0645\u0643\u0646 \u0644\u0628\u0639\u0636 \u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0628\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0623\u0648 \u0625\u0646\u062a\u0631\u0646\u062a \u0627\u0644\u0623\u0634\u064a\u0627\u0621. \u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u0631\u063a\u0628 \u0641\u064a \u0627\u0644\u062a\u062d\u0643\u0645 \u0639\u0646 \u0628\u064f\u0639\u062f \u0623\u0648 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629\u060c \u0641\u0627\u0628\u062d\u062b \u0639\u0646 \u0647\u0630\u0647 \u0627\u0644\u0645\u064a\u0632\u0627\u062a.<\/p><\/li>\n\n\n\n<li><p><strong>\u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u062b\u0628\u064a\u062a<\/strong>: \u0641\u0643\u0631 \u0641\u064a \u0627\u0644\u0645\u0643\u0627\u0646 \u0627\u0644\u0630\u064a \u0633\u062a\u0642\u0648\u0645 \u0628\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u062c\u0647\u0627\u0632 \u0641\u064a\u0647. \u0642\u062f \u064a\u0624\u062b\u0631 \u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0627\u0644\u0645\u0633\u0627\u062d\u0629 \u0639\u0644\u0649 \u0627\u062e\u062a\u064a\u0627\u0631\u0643.<\/p><\/li>\n\n\n\n<li><p><strong>\u0633\u0645\u0639\u0629 \u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/strong>: \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0648\u0641\u0631 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u0629 \u0645\u062b\u0644 Siemens \u0648 Eaton \u0648 Schneider Electric \u0648 Weisho Electric \u062f\u0639\u0645\u064b\u0627 \u0648\u062c\u0648\u062f\u0629 \u0623\u0641\u0636\u0644.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0646\u0638\u0627\u0645\u0643 \u0648\u0627\u0644\u0628\u064a\u0626\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u0642\u0628\u0644 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631 \u0627\u0644\u0646\u0647\u0627\u0626\u064a. \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0623\u0645\u0627\u0646 \u0646\u0638\u0627\u0645\u0643 \u0648\u0643\u0641\u0627\u0621\u062a\u0647.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"practical-recommendations\">\u062a\u0648\u0635\u064a\u0627\u062a \u0639\u0645\u0644\u064a\u0629<\/h3>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u0627\u0633\u062a\u0639\u0627\u0646\u0629 \u0628\u0646\u0635\u0627\u0626\u062d \u0627\u0644\u062e\u0628\u0631\u0627\u0621 \u0644\u0645\u0633\u0627\u0639\u062f\u062a\u0643 \u0641\u064a \u0627\u062e\u062a\u064a\u0627\u0631 \u0623\u0641\u0636\u0644 \u062c\u0647\u0627\u0632 \u0644\u0645\u0628\u0646\u0649 \u0623\u0648 \u0645\u0634\u0631\u0648\u0639\u0643. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0646\u0648\u0639 \u0627\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u0623\u0641\u0636\u0644 \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0628\u064a\u0626\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0623\u0641\u0636\u0644 \u0646\u0648\u0639 \u0645\u0646 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0633\u0628\u0628 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u063a\u0628\u0631\/\u0645\u062a\u0633\u062e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0635\u0645\u064a\u0645 \u0645\u063a\u0644\u0642 \u064a\u062d\u0645\u064a \u0645\u0646 \u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u062c\u0633\u064a\u0645\u0627\u062a<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0631\u0637\u0628\/\u062a\u0622\u0643\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0644\u0627 \u064a\u062d\u062a\u0648\u064a \u0639\u0644\u0649 \u0632\u064a\u062a \u0623\u0648 \u063a\u0627\u0632\u060c \u0645\u0642\u0627\u0648\u0645\u0629 \u0642\u0648\u064a\u0629 \u0644\u0644\u062a\u0622\u0643\u0644<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0633\u0627\u062d\u0629 \u0627\u0644\u0645\u062d\u0635\u0648\u0631\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SF6 \u0623\u0648 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062d\u062c\u0645 \u0635\u063a\u064a\u0631\u060c \u0633\u0647\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062d\u0627\u062c\u0629 \u0639\u0627\u0644\u064a\u0629 \u0644\u0644\u0623\u0645\u0627\u0646<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0644\u0627 \u064a\u0648\u062c\u062f \u062e\u0637\u0631 \u0646\u0634\u0648\u0628 \u062d\u0631\u064a\u0642 \u0623\u0648 \u0627\u0646\u0641\u062c\u0627\u0631<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0623\u064a\u0636\u064b\u0627 \u0627\u062a\u0628\u0627\u0639 \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0627\u062a \u0639\u0646\u062f \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 \u0644\u0646\u0638\u0627\u0645\u0643.<\/p><\/li>\n\n\n\n<li><p>\u0627\u0646\u0638\u0631 \u0625\u0644\u0649 \u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u0633\u0631 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0642\u062f\u0631\u062a\u0647\u0627 \u0639\u0644\u0649 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644.<\/p><\/li>\n\n\n\n<li><p>\u0641\u0643\u0631 \u0641\u064a \u0639\u062f\u062f \u0627\u0644\u0645\u0631\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062d\u062a\u0627\u062c \u0641\u064a\u0647\u0627 \u0625\u0644\u0649 \u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u062f\u0627\u0626\u0631\u0629. \u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0648\u0635\u0644\u064b\u0627 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u060c \u0648\u0645\u0641\u062a\u0627\u062d\u064b\u0627 \u0642\u0627\u0628\u0644\u064b\u0627 \u0644\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (VCB) \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0646\u0627\u062f\u0631\u0629.<\/p><\/li>\n\n\n\n<li><p>\u0636\u0639 \u0627\u0644\u0628\u064a\u0626\u0629 \u0641\u064a \u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631. \u0627\u0633\u062a\u062e\u062f\u0645 VCB \u0641\u064a \u0627\u0644\u0623\u0645\u0627\u0643\u0646 \u0627\u0644\u0642\u0627\u0633\u064a\u0629 \u0623\u0648 \u0627\u0644\u0645\u062a\u0633\u062e\u0629.<\/p><\/li>\n\n\n\n<li><p>\u0627\u062e\u062a\u0631 \u062c\u0647\u0627\u0632\u064b\u0627 \u064a\u062a\u0645\u062a\u0639 \u0628\u0633\u0645\u0639\u0629 \u0637\u064a\u0628\u0629 \u0648\u062f\u0639\u0645 \u0642\u0648\u064a.<\/p><\/li>\n\n\n\n<li><p>\u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0645\u064a\u0632\u0627\u062a \u0630\u0643\u064a\u0629\u060c \u0641\u0627\u062e\u062a\u0631 \u0637\u0631\u0627\u0632\u064b\u0627 \u064a\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0644\u064a \u0644\u062f\u064a\u0643.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\ud83d\udee0\ufe0f <strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0635\u062d\u064a\u062d \u064a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0646\u0638\u0627\u0645\u0643 \u0648\u0623\u0647\u062f\u0627\u0641 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0628\u064a\u0626\u0629. \u062e\u0630 \u0648\u0642\u062a\u0643 \u0641\u064a \u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u062e\u064a\u0627\u0631\u0627\u062a \u0648\u0627\u0633\u062a\u0634\u0631 \u0627\u0644\u062e\u0628\u0631\u0627\u0621 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0644\u062f\u064a\u0643 \u0623\u064a \u0623\u0633\u0626\u0644\u0629.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0644\u0642\u062f \u062a\u0639\u0644\u0645\u062a \u0623\u0646 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 (VCBs) \u062a\u062d\u0645\u064a \u0646\u0638\u0627\u0645\u0643 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0623\u0639\u0637\u0627\u0644\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u062a\u0648\u0644\u0649 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629. \u062a\u0639\u0645\u0644 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0639\u0644\u0649 \u0625\u064a\u0642\u0627\u0641 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062e\u0637\u0631\u0629 \u0648\u062a\u0642\u0644\u064a\u0644 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u062d\u0631\u064a\u0642. \u062a\u0645\u0646\u062d\u0643 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u062d\u0643\u0645\u064b\u0627 \u0645\u0648\u062b\u0648\u0642\u064b\u0627 \u0648\u0639\u0645\u0631\u064b\u0627 \u062a\u0634\u063a\u064a\u0644\u064a\u064b\u0627 \u0637\u0648\u064a\u0644\u064b\u0627. \u064a\u0636\u0645\u0646 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0633\u0644\u0627\u0645\u0629 \u0648\u0643\u0641\u0627\u0621\u0629 \u0646\u0638\u0627\u0645\u0643 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0642\u0648\u0645 VCBs \u0628\u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0648\u0645\u0646\u0639 \u0627\u0644\u0645\u062e\u0627\u0637\u0631.<\/p><\/li>\n\n\n\n<li><p>\u062a\u0642\u0648\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0628\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0648\u062f\u0639\u0645 \u0627\u0644\u0623\u062a\u0645\u062a\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0623\u0641\u0636\u0644 \u0627\u0644\u0646\u062a\u0627\u0626\u062c\u060c \u0631\u0627\u062c\u0639 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0646\u0638\u0627\u0645\u0643 \u0623\u0648 \u0627\u0633\u062a\u0634\u0631 \u062e\u0628\u064a\u0631\u064b\u0627 \u0642\u0628\u0644 \u0627\u062a\u062e\u0627\u0630 \u0642\u0631\u0627\u0631\u0643 \u0627\u0644\u0646\u0647\u0627\u0626\u064a.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-main-difference-between-a-vcb-and-a-contactor\">\u0645\u0627 \u0647\u0648 \u0627\u0644\u0641\u0631\u0642 \u0627\u0644\u0631\u0626\u064a\u0633\u064a \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u061f<\/h3>\n\n\n\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 VCB \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0625\u0644\u0649 \u0627\u0644\u0639\u0627\u0644\u064a. \u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0644\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u062a\u0639\u0645\u0644 VCB \u0639\u0644\u0649 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644. \u062a\u0639\u0645\u0644 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0623\u062d\u0645\u0627\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-use-a-contactor-instead-of-a-vcb\">\u0647\u0644 \u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0648\u0635\u0644 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 VCB\u061f<\/h3>\n\n\n\n<p>\u0644\u0627 \u064a\u062c\u0628 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0648\u0635\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0628\u062f\u0644\u0627\u064b \u0645\u0646 VCB. \u0644\u0627 \u064a\u0645\u0643\u0646 \u0644\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0639\u0637\u0644. \u0641\u0642\u0637 VCBs \u062a\u0648\u0641\u0631 \u062d\u0645\u0627\u064a\u0629 \u0645\u0648\u062b\u0648\u0642\u0629 \u0623\u062b\u0646\u0627\u0621 \u062d\u062f\u0648\u062b \u0642\u0635\u0631 \u0641\u064a \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0623\u0648 \u062d\u0645\u0644 \u0632\u0627\u0626\u062f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"where-do-you-install-vcbs-and-contactors\">\u0623\u064a\u0646 \u064a\u062a\u0645 \u062a\u0631\u0643\u064a\u0628 VCBs \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a\u061f<\/h3>\n\n\n\n<p>\u062a\u0642\u0648\u0645 \u0628\u062a\u0631\u0643\u064a\u0628 VCBs \u0641\u064a \u0644\u0648\u062d\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f. \u062a\u0636\u0639 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0641\u064a \u0645\u0631\u0627\u0643\u0632 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0648\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0648\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0625\u0636\u0627\u0621\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-often-do-you-need-to-maintain-a-vcb-or-contactor\">\u0643\u0645 \u0645\u0631\u0629 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0635\u064a\u0627\u0646\u0629<a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\"> VCB<\/a> \u0623\u0648 <a href=\"https:\/\/xbrele.com\/ar\/vacuum-contactor\/\" data-type=\"page\" data-id=\"1186\">\u0645\u0648\u0635\u0644<\/a>?<\/h3>\n\n\n\n<p>\u062a\u0642\u0648\u0645 \u0628\u0641\u062d\u0635 VCBs \u0643\u0644 1 \u0625\u0644\u0649 3 \u0633\u0646\u0648\u0627\u062a. \u062a\u0642\u0648\u0645 \u0628\u0641\u062d\u0635 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0628\u0634\u0643\u0644 \u0623\u0643\u062b\u0631 \u062a\u0643\u0631\u0627\u0631\u064b\u0627\u060c \u0639\u0627\u062f\u0629\u064b \u0643\u0644 \u0628\u0636\u0639\u0629 \u0623\u0634\u0647\u0631. \u062a\u062d\u062a\u0627\u062c \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0625\u0644\u0649 \u0635\u064a\u0627\u0646\u0629 \u0623\u0643\u062b\u0631 \u062a\u0643\u0631\u0627\u0631\u064b\u0627 \u0644\u0623\u0646\u0647\u0627 \u062a\u062a\u062d\u0648\u0644 \u0628\u0634\u0643\u0644 \u0623\u0643\u062b\u0631 \u062a\u0643\u0631\u0627\u0631\u064b\u0627.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"do-vcbs-and-contactors-cause-voltage-spikes\">\u0647\u0644 \u062a\u0633\u0628\u0628 VCBs \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u061f<\/h3>\n\n\n\n<p>\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 VCBs \u0641\u064a \u062d\u062f\u0648\u062b \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0628\u0633\u0628\u0628 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u064a\u0627\u0631. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0641\u062d\u0635 \u0646\u0638\u0627\u0645\u0643 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0645\u062e\u0627\u0637\u0631 \u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062c\u0647\u062f. \u0646\u0627\u062f\u0631\u0627\u064b \u0645\u0627 \u062a\u062a\u0633\u0628\u0628 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0641\u064a \u062d\u062f\u0648\u062b \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062c\u0647\u062f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"which-device-lasts-longer-a-vcb-or-a-contactor\">\u0623\u064a \u062c\u0647\u0627\u0632 \u064a\u062f\u0648\u0645 \u0644\u0641\u062a\u0631\u0629 \u0623\u0637\u0648\u0644\u060c VCB \u0623\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u061f<\/h3>\n\n\n\n<p>\u062a\u062f\u0648\u0645 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0644\u0641\u062a\u0631\u0629 \u0623\u0637\u0648\u0644 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631. \u062a\u062f\u0648\u0645 VCBs \u0644\u0641\u062a\u0631\u0629 \u0623\u0637\u0648\u0644 \u0639\u0646\u062f \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647\u0627 \u0641\u064a \u0639\u0645\u0644\u064a\u0627\u062a \u062d\u0631\u062c\u0629 \u0639\u0631\u0636\u064a\u0629. \u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0639 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0646\u0638\u0627\u0645\u0643.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-control-both-devices-remotely\">\u0647\u0644 \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0643\u0644\u0627 \u0627\u0644\u062c\u0647\u0627\u0632\u064a\u0646 \u0639\u0646 \u0628\u064f\u0639\u062f\u061f<\/h3>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0643\u0644 \u0645\u0646 VCBs \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0639\u0646 \u0628\u064f\u0639\u062f. \u0627\u0633\u062a\u062e\u062f\u0645 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u0648 \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u0623\u0648 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0644\u0644\u062a\u0634\u063a\u064a\u0644 \u0639\u0646 \u0628\u064f\u0639\u062f.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0646\u0635\u064a\u062d\u0629: \u0627\u062a\u0628\u0639 \u062f\u0627\u0626\u0645\u064b\u0627 \u062a\u0639\u0644\u064a\u0645\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>\u064a\u0643\u0645\u0646 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0648\u0635\u0644 \u0641\u064a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u0628\u062f\u064a\u0644: \u062a\u0639\u0645\u0644 VCBs \u0639\u0644\u0649 \u0642\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0641\u064a \u062d\u0627\u0644\u0629 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u062a\u0648\u0644\u0649 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0645\u0647\u0645\u0629 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0644\u0644\u062d\u0645\u0644.<\/p>","protected":false},"author":3,"featured_media":1535,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-1537","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/1537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=1537"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/1537\/revisions"}],"predecessor-version":[{"id":3526,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/1537\/revisions\/3526"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/1535"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=1537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=1537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=1537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}