{"id":1589,"date":"2025-11-29T21:21:37","date_gmt":"2025-11-29T21:21:37","guid":{"rendered":"https:\/\/xbrele.com\/distribution-transformer-testing-checklist-for-engineers\/"},"modified":"2026-04-07T15:09:21","modified_gmt":"2026-04-07T15:09:21","slug":"distribution-transformer-testing-checklist-for-engineers","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/distribution-transformer-testing-checklist-for-engineers\/","title":{"rendered":"\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0644\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a.jpg\" alt=\"\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0644\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646\" class=\"wp-image-1585\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a.jpg 1408w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-300x164.jpg 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-1024x559.jpg 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-768x419.jpg 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p>\u062a\u0648\u0627\u062c\u0647 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0639\u0646\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0641\u064a \u0627\u0644\u0645\u064a\u062f\u0627\u0646. \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u064a\u0639\u0646\u064a \u0641\u062d\u0635 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0623\u062f\u0627\u0626\u0647 \u0648\u0633\u0644\u0627\u0645\u062a\u0647 \u0642\u0628\u0644 \u062a\u0634\u063a\u064a\u0644\u0647 \u0623\u0648 \u0628\u0639\u062f \u062a\u0634\u063a\u064a\u0644\u0647. \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0641\u064a \u0645\u0646\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0623\u0634\u062e\u0627\u0635 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u062a\u0628\u0627\u0639 \u0646\u0647\u062c \u0645\u0646\u0647\u062c\u064a. \u064a\u062a\u0628\u0639 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0645\u0639\u0627\u064a\u064a\u0631 \u0645\u062b\u0644 IEEE C57.12.00 \u0644\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0645\u063a\u0645\u0648\u0631\u0629 \u0628\u0627\u0644\u0633\u0627\u0626\u0644 \u0648 IEEE C57.12.01 \u0644\u0644\u0646\u0645\u0627\u0630\u062c \u0627\u0644\u062c\u0627\u0641\u0629. \u064a\u0633\u0631\u062f \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647\u0627:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0642\u064a\u0627\u0633\u064a<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE C57.12.00<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0645\u063a\u0645\u0648\u0631\u0629 \u0628\u0627\u0644\u0633\u0627\u0626\u0644<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE C57.12.90<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u062a\u0646\u0638\u064a\u0645<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE C57.12.01<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u062c\u0627\u0641<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE C57.12.91<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062d\u0648\u0644\u0627\u062a \u0637\u0627\u0642\u0629 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u062c\u0627\u0641<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0641\u0647\u0645 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/\">\u0623\u0647\u0645\u064a\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639<\/a> \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629.<\/p><\/li><li><p>\u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0628\u0635\u0631\u064a \u0634\u0627\u0645\u0644 \u0642\u0628\u0644 \u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0627\u0644\u0645\u062d\u062a\u0645\u0644\u0629 \u0645\u062b\u0644 \u0627\u0644\u062a\u0644\u0641 \u0627\u0644\u0645\u0627\u062f\u064a \u0623\u0648 \u062a\u0633\u0631\u0628 \u0627\u0644\u0632\u064a\u062a.<\/p><\/li><li><p>\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629\u060c \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641 \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644\u060c \u0644\u0644\u0643\u0634\u0641 \u0639\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0641\u064a\u0629 \u0648\u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p><\/li><li><p>\u0628\u0634\u0643\u0644 \u0645\u0646\u062a\u0638\u0645 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u062a\u062d\u0644\u064a\u0644 \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a> \u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0645\u0634\u0627\u0643\u0644 \u062f\u0627\u062e\u0644\u064a\u0629.<\/p><\/li><li><p>\u0627\u062a\u0628\u0639 \u062a\u0633\u0644\u0633\u0644 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0646\u0647\u062c\u064a \u0644\u0636\u0645\u0627\u0646 \u0639\u062f\u0645 \u062a\u0641\u0648\u064a\u062a \u0623\u064a \u062e\u0637\u0648\u0627\u062a\u060c \u0628\u062f\u0621\u064b\u0627 \u0645\u0646 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0648\u0627\u0646\u062a\u0647\u0627\u0621\u064b \u0628\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0648\u0638\u064a\u0641\u064a\u0629.<\/p><\/li><li><p>\u0642\u0645 \u0628\u062a\u0648\u062b\u064a\u0642 \u062c\u0645\u064a\u0639 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0628\u062f\u0642\u0629 \u0644\u062a\u062a\u0628\u0639 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0628\u0645\u0631\u0648\u0631 \u0627\u0644\u0648\u0642\u062a \u0648\u062f\u0639\u0645 \u0642\u0631\u0627\u0631\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629.<\/p><\/li><li><p>\u0623\u0639\u0637 \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0644\u0633\u0644\u0627\u0645\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0631\u062a\u062f\u0627\u0621 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0634\u062e\u0635\u064a\u0629 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629 \u0648\u062a\u0642\u064a\u064a\u0645 \u0645\u0648\u0642\u0639 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0627\u0644\u0645\u062e\u0627\u0637\u0631.<\/p><\/li><li><p>\u0627\u0628\u0642 \u0639\u0644\u0649 \u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0623\u0641\u0636\u0644 \u0627\u0644\u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0648\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629 \u0644\u062a\u0639\u0632\u064a\u0632 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0634\u0628\u0643\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0643\u064a\u0641\u064a\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/cmvZoWYE-No?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u063a\u0631\u0636 \u0648\u0627\u0644\u0646\u0637\u0627\u0642<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0641\u0647\u0645 \u0633\u0628\u0628 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/dry-type-transformer\/\">\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a> \u0627\u0644\u0623\u0645\u0648\u0631 \u0642\u0628\u0644 \u0627\u0644\u0628\u062f\u0621 \u0641\u064a \u0623\u064a \u0639\u0645\u0644. \u062a\u062a\u062d\u0642\u0642 \u0647\u0630\u0647 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0645\u0646 \u0633\u0644\u0627\u0645\u0629 \u0648\u0633\u0644\u0627\u0645\u0629 \u0648\u0623\u062f\u0627\u0621 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0641\u064a \u0634\u0628\u0643\u062a\u0643. \u062a\u0633\u062a\u062e\u062f\u0645 \u0647\u0630\u0647 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0644\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0641\u064a\u0629 \u0648\u0642\u064a\u0627\u0633 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0648\u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u064a\u0641\u064a \u0628\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u062a\u062d\u0642\u0642 \u062f\u0627\u0626\u0645\u064b\u0627 \u0645\u0646 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u064a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0644\u0649 \u0645\u0646\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0637\u064a\u0631\u0629 \u0648\u064a\u0636\u0645\u0646 \u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0628\u0623\u0645\u0627\u0646.<\/p><\/blockquote>\n\n\n\n<p>\u062a\u0633\u0644\u0637 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0627\u0644\u0636\u0648\u0621 \u0639\u0644\u0649 \u0639\u062f\u0629 \u0623\u0647\u062f\u0627\u0641 \u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0645\u0627 \u062a\u0647\u062f\u0641 \u0625\u0644\u0649 \u062a\u062d\u0642\u064a\u0642\u0647:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0647\u062f\u0641<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0648\u0635\u0641<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0636\u0645\u0627\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0633\u0627\u0639\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0644\u0649 \u0645\u0646\u0639 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u062d\u0631\u064a\u0642 \u0648\u0627\u0646\u0641\u062c\u0627\u0631\u0627\u062a \u0627\u0644\u0632\u064a\u062a \u0648\u0627\u0644\u062d\u0648\u0627\u062f\u062b \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0646\u0627\u062c\u0645\u0629 \u0639\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u063a\u064a\u0631 \u0627\u0644\u0645\u0643\u062a\u0634\u0641\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0643\u0634\u0641 \u0627\u0644\u0645\u0628\u0643\u0631 \u0639\u0646 \u0627\u0644\u0639\u064a\u0648\u0628 \u0644\u062a\u062c\u0646\u0628 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0627\u0631\u062b\u064a\u0629 \u0648\u062a\u0642\u0644\u064a\u0644 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0625\u0644\u0649 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0636\u0645\u0646 \u0627\u0644\u0627\u0644\u062a\u0632\u0627\u0645 \u0628\u0645\u0639\u0627\u064a\u064a\u0631 IEC \u0648 IEEE\u060c \u0648\u0627\u0644\u062a\u064a \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0643\u0648\u0646 \u0645\u0637\u0644\u0648\u0628\u0629 \u0642\u0627\u0646\u0648\u0646\u064b\u0627 \u0644\u0625\u062c\u0631\u0627\u0621 \u0639\u0645\u0644\u064a\u0627\u062a \u062a\u062f\u0642\u064a\u0642 \u0627\u0644\u0633\u0644\u0627\u0645\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u062e\u0641\u064a\u0636 \u0627\u0644\u062a\u0643\u0627\u0644\u064a\u0641<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062a\u064a\u062d \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0642\u0627\u0626\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u062d\u0627\u0644\u0629\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u064a\u0637\u064a\u0644 \u0645\u0646 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u0634\u0628\u0643\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062f\u0639\u0645 \u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u064a\u0645\u0646\u0639 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u0642\u062f \u062a\u0624\u062f\u064a \u0625\u0644\u0649 \u0639\u062f\u0645 \u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u0634\u0628\u0643\u0629.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0633\u062a\u0642\u0648\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0639\u062f\u0629 \u0623\u0646\u0648\u0627\u0639 \u0645\u0646 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u0648\u062a\u0634\u0645\u0644 \u0647\u0630\u0647 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c, <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a<\/a>, \u060c \u0648\u0641\u062d\u0648\u0635\u0627\u062a \u0648\u0638\u064a\u0641\u064a\u0629. \u064a\u0648\u0641\u0631 \u0644\u0643 \u0643\u0644 \u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u064a\u0627\u0646\u0627\u062a \u0645\u0647\u0645\u0629 \u0639\u0646 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0645\u0632\u0627\u064a\u0627 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n\n\n\n<p>\u0639\u0646\u062f \u0627\u062a\u0628\u0627\u0639 \u0646\u0647\u062c \u0645\u0646\u0647\u062c\u064a \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u060c \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0632\u0627\u064a\u0627. \u064a\u0645\u0643\u0646\u0643 \u0627\u0643\u062a\u0634\u0627\u0641 \u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0639\u0632\u0644 \u0641\u064a \u0648\u0642\u062a \u0645\u0628\u0643\u0631 \u0648\u0627\u0644\u062a\u062e\u0637\u064a\u0637 \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0642\u0628\u0644 \u062d\u062f\u0648\u062b \u0623\u064a \u0639\u0637\u0644. \u0648\u0647\u0630\u0627 \u064a\u0648\u0641\u0631 \u0644\u0643 \u0627\u0644\u0645\u0627\u0644 \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u064a\u0631 \u0634\u0628\u0643\u062a\u0643 \u0628\u0633\u0644\u0627\u0633\u0629.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0642\u0648\u0645 \u0628\u062c\u0645\u0639 \u0628\u064a\u0627\u0646\u0627\u062a \u0639\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0648\u062c\u0648\u062f\u0629 \u0627\u0644\u0632\u064a\u062a\u060c \u0645\u0645\u0627 \u064a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u0627\u062a\u062e\u0627\u0630 \u0642\u0631\u0627\u0631\u0627\u062a \u0635\u064a\u0627\u0646\u0629 \u0630\u0643\u064a\u0629.<\/p><\/li><li><p>\u064a\u062a\u064a\u062d \u0644\u0643 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0645\u0646\u062a\u0638\u0645 \u0644\u0644\u0632\u064a\u062a \u0645\u0631\u0627\u0642\u0628\u0629 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0627\u0643\u062a\u0634\u0627\u0641 \u0645\u0634\u0627\u0643\u0644 \u0645\u062b\u0644 \u062d\u062f\u0648\u062b \u0642\u0648\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u0648 \u062a\u0642\u0627\u062f\u0645 \u0627\u0644\u0639\u0627\u0632\u0644.<\/p><\/li><li><p>\u062a\u0633\u0627\u0639\u062f\u0643 \u0623\u0646\u0638\u0645\u0629 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062d\u0627\u0644\u0629 \u0639\u0644\u0649 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0627\u0633\u062a\u062f\u0627\u0645\u062a\u0647\u0627.<\/p><\/li><li><p>\u064a\u0645\u0643\u0646\u0643 \u0645\u0646\u0639 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062e\u0637\u0637 \u0644\u0647\u0627 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0641\u064a \u0648\u0642\u062a \u0645\u0628\u0643\u0631.<\/p><\/li><li><p>\u062a\u0642\u0644\u0644 \u0627\u0644\u0642\u0631\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0645\u062f\u0629 \u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0648\u062a\u062d\u0633\u0646 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0634\u0628\u0643\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u062a\u0631\u0649 \u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0639\u0627\u0645\u0629 \u0641\u0648\u0627\u0626\u062f \u0648\u0627\u0636\u062d\u0629 \u0645\u0646 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0646\u062a\u0638\u0645\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0628\u0639\u0636 \u0647\u0630\u0647 \u0627\u0644\u0645\u0632\u0627\u064a\u0627:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0641\u0627\u0626\u062f\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0648\u0635\u0641<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0643\u0634\u0641 \u0627\u0644\u0645\u0628\u0643\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062d\u062f\u062f \u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u0639\u0632\u0644 \u0641\u064a \u0645\u0631\u062d\u0644\u0629 \u0645\u0628\u0643\u0631\u0629\u060c \u0645\u0645\u0627 \u064a\u062a\u064a\u062d \u0625\u062c\u0631\u0627\u0621 \u0635\u064a\u0627\u0646\u0629 \u0627\u0633\u062a\u0628\u0627\u0642\u064a\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u062a\u0643\u0627\u0644\u064a\u0641<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0645\u0646\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0627\u0631\u062b\u064a\u0629 \u0648\u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062e\u0637\u0637 \u0644\u0647\u0627\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0648\u0627\u0644\u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0644\u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0647.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0645\u062d\u0633\u0646\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0639\u0632\u0632 \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0648\u0627\u0644\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u0639\u0627\u0645\u064a\u0646 \u0644\u0634\u0628\u0643\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u062d\u0645\u0627\u064a\u0629 \u0623\u0635\u0648\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0623\u0646\u062a \u062a\u0644\u0639\u0628 \u062f\u0648\u0631\u064b\u0627 \u0631\u0626\u064a\u0633\u064a\u064b\u0627 \u0641\u064a \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0623\u0645\u0627\u0646 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0634\u0628\u0643\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u062a\u0628\u0627\u0639 \u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0634\u0627\u0645\u0644\u0629\u060c \u062a\u0633\u0627\u0639\u062f \u0641\u0631\u064a\u0642\u0643 \u0639\u0644\u0649 \u062a\u062c\u0646\u0628 \u0627\u0644\u0625\u0635\u0644\u0627\u062d\u0627\u062a \u0627\u0644\u0645\u0643\u0644\u0641\u0629 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0633\u062a\u0645\u0631\u0627\u0631 \u062a\u062f\u0641\u0642 \u0627\u0644\u0637\u0627\u0642\u0629.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0644\u062a\u062d\u0636\u064a\u0631<\/h2>\n\n\n\n<p>\u0642\u0628\u0644 \u0623\u0646 \u062a\u0628\u062f\u0623 \u0623\u064a \u0634\u064a\u0621 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/\">\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639<\/a>, \u060c \u0639\u0644\u064a\u0643 \u0627\u0644\u0627\u0633\u062a\u0639\u062f\u0627\u062f \u0628\u0639\u0646\u0627\u064a\u0629. \u0627\u0644\u0627\u0633\u062a\u0639\u062f\u0627\u062f \u0627\u0644\u062c\u064a\u062f \u064a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u062a\u062c\u0646\u0628 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u062a\u0643. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062f\u0627\u0626\u0645\u064b\u0627 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0627\u062a \u0627\u0644\u0645\u0647\u0645\u0629 \u0648\u0627\u062a\u0628\u0627\u0639 \u0642\u0648\u0627\u0639\u062f \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u062c\u0645\u0639 \u0627\u0644\u0623\u062f\u0648\u0627\u062a \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0648\u062b\u0627\u0626\u0642<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629 \u0642\u0628\u0644 \u0627\u0644\u0628\u062f\u0621. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0629 \u0639\u0644\u0649 \u0641\u0647\u0645 \u062a\u0627\u0631\u064a\u062e \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0627\u0644\u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0647. \u0643\u0645\u0627 \u062a\u0633\u0627\u0639\u062f\u0643 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0627\u062a \u0639\u0644\u0649 \u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0648\u062a\u062d\u062f\u064a\u062f \u0623\u064a \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u062e\u0627\u0635\u0629.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0644\u0648\u062d\u0629<\/h4>\n\n\n\n<p>\u0627\u0628\u062f\u0623 \u0628\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629 \u0644\u0644\u0645\u062d\u0648\u0644. \u062a\u0648\u0641\u0631 \u0644\u0643 \u0627\u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629 \u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0623\u0633\u0627\u0633\u064a\u0629 \u0645\u062b\u0644 \u0642\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0648\u0627\u0644\u0631\u0642\u0645 \u0627\u0644\u062a\u0633\u0644\u0633\u0644\u064a. \u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0647\u0630\u0647 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u064a\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 \u0645\u0648\u0627\u0635\u0641\u0627\u062a\u0647. \u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u062a\u0633\u062c\u064a\u0644 \u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629 \u0641\u064a \u0633\u062c\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629<\/h4>\n\n\n\n<p>\u0628\u0639\u062f \u0630\u0644\u0643\u060c \u0631\u0627\u062c\u0639 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629. \u062a\u0648\u0641\u0631 \u0647\u0630\u0647 \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0627\u062a \u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0639\u0646 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0648\u0627\u0644\u0645\u0648\u0627\u062f \u0648\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647\u0627. \u0643\u0645\u0627 \u0623\u0646\u0647\u0627 \u062a\u062d\u062f\u062f \u062d\u062f\u0648\u062f \u0642\u064a\u0645 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u0623\u064a \u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u0628\u064a\u0646 \u0627\u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u062a\u0639\u0631\u064a\u0641\u064a\u0629 \u0648\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a\u060c \u0641\u0642\u0645 \u0628\u062a\u062f\u0648\u064a\u0646\u0647\u0627 \u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u062a\u062d\u0642\u064a\u0642.<\/p>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0623\u064a\u0636\u064b\u0627 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0633\u0627\u0628\u0642\u0629 \u0648\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u062a\u062b\u0628\u064a\u062a. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0642\u0627\u0626\u0645\u0629 \u0628\u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0645\u0631\u0627\u062c\u0639\u062a\u0647\u0627:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 (\u0645\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0646\u0633\u0628\u0629 \u0648\u0627\u0644\u0642\u0637\u0628\u064a\u0629 \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0648\u0646\u0638\u0627\u0645 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0633\u062c\u064a\u0644 \u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u062a\u062f\u0627\u0628\u064a\u0631 \u0627\u0644\u0633\u0644\u0627\u0645\u0629<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0636\u0639 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u062f\u0627\u0626\u0645\u064b\u0627 \u0641\u064a \u0627\u0644\u0645\u0642\u0627\u0645 \u0627\u0644\u0623\u0648\u0644. \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0634\u0643\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u062e\u0637\u0631\u064b\u0627 \u0625\u0630\u0627 \u0644\u0645 \u062a\u062a\u0628\u0639 \u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0635\u062d\u064a\u062d\u0629. \u062e\u0630 \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0643\u0627\u0641\u064a \u0644\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0645\u0648\u0642\u0639 \u0648\u0627\u0631\u062a\u062f\u0650 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0634\u062e\u0635\u064a\u0629<\/h4>\n\n\n\n<p>\u0627\u0631\u062a\u062f\u0650 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0634\u062e\u0635\u064a\u0629 (PPE) \u0645\u062b\u0644 \u0627\u0644\u0642\u0641\u0627\u0632\u0627\u062a \u0627\u0644\u0639\u0627\u0632\u0644\u0629 \u0648\u0627\u0644\u0646\u0638\u0627\u0631\u0627\u062a \u0627\u0644\u0648\u0627\u0642\u064a\u0629 \u0648\u0627\u0644\u0645\u0644\u0627\u0628\u0633 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0647\u0628. \u062a\u062d\u0645\u064a\u0643 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0634\u062e\u0635\u064a\u0629 \u0645\u0646 \u0627\u0644\u0635\u062f\u0645\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u062d\u0631\u0648\u0642 \u0648\u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0623\u062e\u0631\u0649. \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0645\u0639\u062f\u0627\u062a\u0643 \u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0643 \u0648\u062a\u0641\u064a \u0628\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0633\u0644\u0627\u0645\u0629.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0645\u0648\u0642\u0639<\/h4>\n\n\n\n<p>\u062a\u062c\u0648\u0644 \u0641\u064a \u0627\u0644\u0645\u0648\u0642\u0639 \u0642\u0628\u0644 \u0627\u0644\u0628\u062f\u0621. \u0627\u0628\u062d\u062b \u0639\u0646 \u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0645\u062b\u0644 \u0627\u0644\u0623\u0633\u0637\u062d \u0627\u0644\u0645\u0628\u0644\u0644\u0629 \u0623\u0648 \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0627\u0644\u0633\u064a\u0626\u0629 \u0623\u0648 \u0627\u0644\u0639\u0648\u0627\u0626\u0642. \u062a\u0623\u0643\u062f \u0645\u0646 \u062e\u0644\u0648 \u0627\u0644\u0645\u0646\u0637\u0642\u0629 \u0645\u0646 \u0627\u0644\u0623\u0634\u062e\u0627\u0635 \u063a\u064a\u0631 \u0627\u0644\u0645\u0635\u0631\u062d \u0644\u0647\u0645. \u062a\u0623\u0643\u062f \u0645\u0646 \u062a\u0646\u0641\u064a\u0630 \u062c\u0645\u064a\u0639 \u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0642\u0641\u0644 \u0648\u0627\u0644\u062a\u0648\u0633\u064a\u0645. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0629 \u0639\u0644\u0649 \u062a\u062c\u0646\u0628 \u0627\u0644\u062d\u0648\u0627\u062f\u062b \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0641\u0631\u064a\u0642\u0643.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0623\u062f\u0648\u0627\u062a \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a<\/h3>\n\n\n\n<p>\u0627\u062c\u0645\u0639 \u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u062f\u0648\u0627\u062a \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0642\u0628\u0644 \u0627\u0644\u0628\u062f\u0621 \u0641\u064a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u0633\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0623\u062c\u0647\u0632\u0629 \u0645\u0639\u0627\u064a\u0631\u0629 \u0645\u062b\u0644 \u0623\u062c\u0647\u0632\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644\u060c \u0648\u0623\u062c\u0647\u0632\u0629 \u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641\u060c \u0648\u0623\u062c\u0647\u0632\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0646\u0633\u0628\u0629 \u0627\u0644\u062f\u0648\u0631\u0627\u062a. \u0623\u062d\u0636\u0631 \u0623\u062f\u0648\u0627\u062a \u064a\u062f\u0648\u064a\u0629 \u0648\u0645\u0633\u062a\u0644\u0632\u0645\u0627\u062a \u0627\u0644\u062a\u0646\u0638\u064a\u0641 \u0648\u0643\u0627\u0645\u064a\u0631\u0627 \u0644\u0644\u062a\u0648\u062b\u064a\u0642. \u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d \u0648\u0623\u0646 \u0644\u062f\u064a\u0647\u0627 \u0634\u0647\u0627\u062f\u0627\u062a \u0645\u0639\u0627\u064a\u0631\u0629 \u0635\u0627\u0644\u062d\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u062a\u062d\u0642\u0642 \u062f\u0627\u0626\u0645\u064b\u0627 \u0645\u0646 \u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0642\u0628\u0644 \u0627\u0644\u0645\u063a\u0627\u062f\u0631\u0629 \u0625\u0644\u0649 \u0627\u0644\u0645\u0648\u0642\u0639. \u0641\u0642\u062f \u064a\u0624\u062f\u064a \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u0623\u062f\u0648\u0627\u062a \u0625\u0644\u0649 \u062a\u0623\u062e\u064a\u0631 \u0639\u0645\u0644\u0643 \u0648\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u0645\u062e\u0627\u0637\u0631.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3.webp\" alt=\"\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a\" class=\"wp-image-1586\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0635\u062f\u0631 \u0627\u0644\u0635\u0648\u0631\u0629: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">pexels<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u064a\u0645\u0646\u062d\u0643 \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a \u0623\u0648\u0644 \u062f\u0644\u0627\u0626\u0644 \u0639\u0646 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644. \u064a\u0645\u0643\u0646\u0643 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0642\u0628\u0644 \u0623\u0646 \u062a\u0635\u0628\u062d \u062e\u0637\u064a\u0631\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0641\u062d\u0635 \u0627\u0644\u0648\u062d\u062f\u0629 \u0648\u0623\u062c\u0632\u0627\u0626\u0647\u0627 \u0639\u0646 \u0643\u062b\u0628. \u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0628\u0635\u0631\u064a \u0642\u0628\u0644 \u0625\u062c\u0631\u0627\u0621 \u0623\u064a \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0636\u0648\u0627\u0628\u0637 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0627\u0644\u0623\u0636\u0631\u0627\u0631 \u0627\u0644\u0645\u0627\u062f\u064a\u0629<\/h4>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u0641\u0627\u0641 \u062d\u0648\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0627\u0644\u0628\u062d\u062b \u0639\u0646 \u0623\u064a \u0639\u0644\u0627\u0645\u0627\u062a \u062a\u062f\u0644 \u0639\u0644\u0649 \u0648\u062c\u0648\u062f \u062a\u0644\u0641 \u0645\u0627\u062f\u064a. \u0627\u0646\u062a\u0628\u0647 \u0625\u0644\u0649 \u0627\u0644\u062e\u0632\u0627\u0646 \u0648\u0627\u0644\u063a\u0644\u0627\u0641 \u0648\u0623\u062f\u0648\u0627\u062a \u0627\u0644\u062a\u062b\u0628\u064a\u062a. \u062a\u0634\u0645\u0644 \u0627\u0644\u0645\u0624\u0634\u0631\u0627\u062a \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0639\u0644\u0649 \u0648\u062c\u0648\u062f \u0645\u0634\u0643\u0644\u0629 \u0645\u0627 \u064a\u0644\u064a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0634\u0642\u0642\u0627\u062a \u0623\u0648 \u062e\u062f\u0648\u0634 \u0641\u064a \u0627\u0644\u062e\u0632\u0627\u0646 \u0623\u0648 \u0627\u0644\u063a\u0644\u0627\u0641<\/p><\/li><li><p>\u0627\u0644\u0635\u062f\u0623 \u0623\u0648 \u0627\u0644\u062a\u0622\u0643\u0644 \u0639\u0644\u0649 \u0627\u0644\u0623\u0633\u0637\u062d \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629<\/p><\/li><li><p>\u0628\u0631\u0627\u063a\u064a \u0648\u0645\u062b\u0628\u062a\u0627\u062a \u0645\u0641\u0643\u0648\u0643\u0629 \u0623\u0648 \u0645\u0641\u0642\u0648\u062f\u0629<\/p><\/li><li><p>\u0639\u0644\u0627\u0645\u0627\u062a \u062d\u0631\u0642 \u0623\u0648 \u062a\u063a\u064a\u0631 \u0641\u064a \u0627\u0644\u0644\u0648\u0646 \u0628\u0627\u0644\u0642\u0631\u0628 \u0645\u0646 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0635\u0628\u0627\u062d\u064b\u0627 \u064a\u062f\u0648\u064a\u064b\u0627 \u0644\u0641\u062d\u0635 \u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u062a\u064a \u064a\u0635\u0639\u0628 \u0631\u0624\u064a\u062a\u0647\u0627. \u0627\u0644\u062a\u0642\u0637 \u0635\u0648\u0631\u064b\u0627 \u0644\u0623\u064a \u0623\u0636\u0631\u0627\u0631 \u0644\u062a\u0633\u062c\u064a\u0644\u0647\u0627 \u0641\u064a \u0633\u062c\u0644\u0627\u062a\u0643.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u062a\u0633\u0631\u0628\u0627\u062a \u0627\u0644\u0632\u064a\u062a<\/h4>\n\n\n\n<p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u062a\u0633\u0631\u0628\u0627\u062a \u0627\u0644\u0632\u064a\u062a<\/a> \u0642\u062f \u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0645\u0634\u0627\u0643\u0644 \u062f\u0627\u062e\u0644\u064a\u0629 \u062e\u0637\u064a\u0631\u0629. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0641\u062d\u0635 \u062c\u0645\u064a\u0639 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0648\u0627\u0644\u062d\u0634\u064a\u0627\u062a \u0648\u0627\u0644\u062a\u062c\u0647\u064a\u0632\u0627\u062a \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u0633\u0631\u0628. \u0627\u0628\u062d\u062b \u0639\u0646:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0628\u0642\u0639 \u0632\u064a\u062a \u0639\u0644\u0649 \u0627\u0644\u062e\u0632\u0627\u0646 \u0623\u0648 \u0627\u0644\u0623\u0631\u0636<\/p><\/li><li><p>\u0628\u0642\u0639 \u0631\u0637\u0628\u0629 \u062d\u0648\u0644 \u0627\u0644\u062d\u0634\u064a\u0627\u062a \u0623\u0648 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a<\/p><\/li><li><p>\u062a\u0633\u0627\u0642\u0637 \u0642\u0637\u0631\u0627\u062a \u0623\u0648 \u062a\u0643\u0648\u0651\u0646 \u0628\u0631\u0643 \u062a\u062d\u062a \u0627\u0644\u0645\u062d\u0648\u0644<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u062a\u0633\u0631\u0628\u0627\u062a \u0644\u0644\u0632\u064a\u062a\u060c \u0641\u0642\u0645 \u0628\u062a\u0633\u062c\u064a\u0644 \u0645\u0648\u0642\u0639\u0647\u0627 \u0648\u062d\u062c\u0645\u0647\u0627. \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0627\u0644\u062a\u0633\u0631\u0628\u0627\u062a \u0625\u0644\u0649 \u0641\u0634\u0644 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0648\u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u062a\u0639\u062f \u062a\u0633\u0631\u0628\u0627\u062a \u0627\u0644\u0632\u064a\u062a \u0648\u0627\u0644\u0634\u0642\u0648\u0642 \u0648\u0627\u0644\u062a\u0622\u0643\u0644 \u0645\u0646 \u0623\u0643\u062b\u0631 \u0627\u0644\u0645\u0624\u0634\u0631\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0634\u064a\u0648\u0639\u064b\u0627 \u0644\u0641\u0634\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0631\u0642\u0627\u0628\u0629 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0627\u0644\u0644\u0628 \u0648\u0627\u0644\u0645\u0644\u0641\u0627\u062a<\/h4>\n\n\n\n<p>\u064a\u062c\u0628 \u0641\u062d\u0635 \u0627\u0644\u0642\u0644\u0628 \u0648\u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0625\u0630\u0627 \u0643\u0627\u0646 \u0628\u0625\u0645\u0643\u0627\u0646\u0643 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u064a\u0647\u0627. \u0627\u062a\u0628\u0639 \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0627\u062a \u0644\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0634\u0627\u0645\u0644:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0642\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0645\u0627\u062f\u064a. \u062a\u062d\u0642\u0642 \u0645\u0646 \u0633\u0645\u0627\u0643\u0629 \u0627\u0644\u0637\u0628\u0642\u0627\u062a\u060c \u0648\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0646\u0648\u0627\u0641\u0630\u060c \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0643\u0644\u064a. \u0633\u062c\u0644 \u0642\u0631\u0627\u0621\u0627\u062a\u0643 \u0648\u0642\u0627\u0631\u0646\u0647\u0627 \u0628\u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u062a\u0635\u0645\u064a\u0645\u064a\u0629.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0632\u0644 \u0627\u0644\u0642\u0644\u0628. \u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 (IR) \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0642\u0635\u0631 \u0628\u064a\u0646 \u0627\u0644\u0642\u0644\u0628 \u0648\u0627\u0644\u0645\u0634\u0627\u0628\u0643 \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629. \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0642\u064a\u0645 IR \u062a\u0641\u064a \u0628\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0633\u0645\u0627\u0643\u0629 \u0648\u0639\u0631\u0636 \u0634\u0631\u0627\u0626\u0637 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a. \u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u062f\u062f \u0627\u0644\u0623\u0642\u0631\u0627\u0635 \u0641\u064a \u0643\u0644 \u0644\u0641.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641. \u0627\u0633\u062a\u062e\u062f\u0645 \u0637\u0631\u064a\u0642\u0629 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0639\u0646 \u0637\u0631\u064a\u0642 \u062d\u0642\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0648\u0642\u064a\u0627\u0633 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0639\u0628\u0631 \u0627\u0644\u0644\u0641.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0627\u062a \u0641\u064a \u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0645\u0634\u0627\u0643\u0644 \u0645\u062b\u0644 \u0627\u0644\u0627\u0646\u0639\u0637\u0627\u0641\u0627\u062a \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0623\u0648 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0633\u0627\u0626\u0628\u0629 \u0623\u0648 \u0639\u064a\u0648\u0628 \u0627\u0644\u062a\u0635\u0646\u064a\u0639.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0627\u0644\u0639\u0632\u0644<\/h4>\n\n\n\n<p>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0639\u0632\u0644 \u0639\u0644\u0649 \u062c\u0645\u064a\u0639 \u0627\u0644\u0644\u0641\u0627\u062a \u0648\u0627\u0644\u0648\u0635\u0644\u0627\u062a. \u0627\u0628\u062d\u062b \u0639\u0646:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u063a\u064a\u0631 \u0627\u0644\u0644\u0648\u0646 \u0623\u0648 \u0627\u0644\u062a\u0641\u062d\u0645<\/p><\/li><li><p>\u062a\u0634\u0642\u0642\u0627\u062a \u0623\u0648 \u062a\u0642\u0634\u0631<\/p><\/li><li><p>\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0627\u0644\u062a\u0644\u0648\u062b<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u062c\u064a\u062f \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0645\u0644\u062d\u0642\u0627\u062a<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a<\/h4>\n\n\n\n<p>\u0627\u0641\u062d\u0635 \u062c\u0645\u064a\u0639 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u062a\u0634\u0642\u0642\u0627\u062a \u0623\u0648 \u0634\u0642\u0648\u0642 \u0623\u0648 \u062a\u0644\u0648\u062b. \u062a\u0633\u0627\u0639\u062f \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0627\u0644\u0646\u0638\u064a\u0641\u0629 \u0639\u0644\u0649 \u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0627\u0646\u062f\u0644\u0627\u0639 \u0634\u0631\u0627\u0631\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0623\u0639\u0637\u0627\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0627\u0633\u062a\u0628\u062f\u0644 \u0623\u064a \u0628\u0637\u0627\u0646\u0627\u062a \u062a\u0627\u0644\u0641\u0629 \u0639\u0644\u0649 \u0627\u0644\u0641\u0648\u0631.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0628\u0631\u064a\u062f<\/h4>\n\n\n\n<p>\u0627\u0641\u062d\u0635 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0627\u0646\u0633\u062f\u0627\u062f\u0627\u062a \u0623\u0648 \u062a\u0633\u0631\u0628\u0627\u062a \u0623\u0648 \u0645\u0631\u0627\u0648\u062d \u0645\u0643\u0633\u0648\u0631\u0629. \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u0628\u0631\u062f\u0627\u062a \u0648\u0631\u064a\u0634 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0646\u0638\u064a\u0641\u0629 \u0648\u062e\u0627\u0644\u064a\u0629 \u0645\u0646 \u0627\u0644\u0623\u0648\u0633\u0627\u062e. \u064a\u0645\u0646\u0639 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0641\u0639\u0627\u0644 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u064a\u0637\u064a\u0644 \u0645\u0646 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u062a\u0630\u0643\u0631:<\/strong> \u064a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a \u0627\u0644\u062f\u0642\u064a\u0642 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0645\u0628\u0643\u0631\u0627\u064b \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0628\u0623\u0645\u0627\u0646.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0627\u0644\u062a\u0641\u0627\u0641<\/h3>\n\n\n\n<p>\u062a\u0628\u062f\u0623 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0628\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641. \u064a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u064a \u0627\u0643\u062a\u0634\u0627\u0641 \u0645\u0634\u0627\u0643\u0644 \u0645\u062b\u0644 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0645\u0641\u0643\u0648\u0643\u0629 \u0623\u0648 \u0627\u0644\u062e\u064a\u0648\u0637 \u0627\u0644\u0645\u0642\u0637\u0648\u0639\u0629 \u0623\u0648 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0636\u0639\u064a\u0641\u0629 \u062f\u0627\u062e\u0644 \u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644. \u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0631\u0642\u0645\u064a \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 (DLRO) \u0623\u0648 \u0623\u062f\u0627\u0629 \u0645\u0645\u0627\u062b\u0644\u0629 \u0644\u0647\u0630\u0647 \u0627\u0644\u0645\u0647\u0645\u0629.<\/p>\n\n\n\n<p>\u0644\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0642\u0645 \u0623\u0648\u0644\u0627\u064b \u0628\u0641\u0635\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0646 \u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629. \u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0645\u062d\u0648\u0644. \u0642\u0645 \u0628\u062d\u0642\u0646 \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0635\u063a\u064a\u0631 \u0648\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0639\u0628\u0631 \u0627\u0644\u0645\u0644\u0641. \u064a\u0642\u0648\u0645 \u0627\u0644\u062c\u0647\u0627\u0632 \u0628\u062d\u0633\u0627\u0628 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0642\u0627\u0646\u0648\u0646 \u0623\u0648\u0645.<\/p>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0627\u0644\u062a\u0648\u0627\u0621:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u063a\u064a\u0631 \u0645\u0632\u0648\u062f \u0628\u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0645\u0624\u0631\u0636.<\/p><\/li><li><p>\u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0644\u0641 \u0627\u0644\u0635\u062d\u064a\u062d\u0629.<\/p><\/li><li><p>\u0627\u062a\u0631\u0643 \u0627\u0644\u0642\u0631\u0627\u0621\u0627\u062a \u062a\u0633\u062a\u0642\u0631 \u0642\u0628\u0644 \u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u0642\u064a\u0645\u0629.<\/p><\/li><li><p>\u0642\u0627\u0631\u0646 \u0646\u062a\u0627\u0626\u062c\u0643 \u0628\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629.<\/p><\/li>\n<\/ol>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u062e\u062a\u0628\u0631 \u062f\u0627\u0626\u0645\u064b\u0627 \u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0644\u0641\u0627\u062a \u2014 \u0627\u0644\u0623\u0648\u0644\u064a\u0629 \u0648\u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0648\u0627\u0644\u062b\u0627\u0644\u062b\u064a\u0629 \u0625\u0646 \u0648\u062c\u062f\u062a. \u0633\u062c\u0644 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u062d\u064a\u062b \u062a\u062a\u063a\u064a\u0631 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0645\u0639 \u062a\u063a\u064a\u0631 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629.<\/p><\/blockquote>\n\n\n\n<p>\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0634\u064a\u0631 \u0642\u064a\u0645 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u063a\u064a\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0625\u0644\u0649 \u0645\u0634\u0643\u0644\u0627\u062a \u0645\u062b\u0644 \u0627\u0644\u062f\u0648\u0631\u0627\u062a \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0623\u0648 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062d\u0643\u0645\u0629. \u064a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0628\u0643\u0631 \u0639\u0644\u0649 \u0645\u0646\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 (Megger)<\/h3>\n\n\n\n<p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644<\/a>, \u060c \u0648\u0627\u0644\u0630\u064a \u064a\u064f\u0639\u0631\u0641 \u063a\u0627\u0644\u0628\u064b\u0627 \u0628\u0627\u0633\u0645 \u201c\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u064a\u063a\u0648\u0645\u062a\u0631\u201d\u060c \u064a\u062a\u062d\u0642\u0642 \u0645\u0646 \u062c\u0648\u062f\u0629 \u0627\u0644\u0639\u0632\u0644 \u0628\u064a\u0646 \u0627\u0644\u0644\u0641\u0627\u062a \u0648\u0628\u064a\u0646 \u0627\u0644\u0644\u0641\u0627\u062a \u0648\u0627\u0644\u0623\u0631\u0636. \u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u064a\u063a\u0648\u0645\u062a\u0631 \u0644\u0625\u062c\u0631\u0627\u0621 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u062c\u064a\u062f \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0644\u0645\u062d\u0648\u0644 \u0622\u0645\u0646\u064b\u0627 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u062a\u0644\u0641 \u0627\u0644\u0631\u0637\u0648\u0628\u0629.<\/p>\n\n\n\n<p>\u0644\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0627\u0641\u0635\u0644 \u062c\u0645\u064a\u0639 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 \u0639\u0646 \u0627\u0644\u0645\u062d\u0648\u0644. \u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0628\u064a\u0646 \u0627\u0644\u0645\u0644\u0641 \u0648\u0627\u0644\u0623\u0631\u0636. \u0642\u0645 \u0628\u062a\u0637\u0628\u064a\u0642 \u062c\u0647\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 (\u0639\u0627\u062f\u0629\u064b 500 \u0641\u0648\u0644\u062a \u0623\u0648 1000 \u0641\u0648\u0644\u062a \u0623\u0648 2500 \u0641\u0648\u0644\u062a \u062d\u0633\u0628 \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0645\u062d\u0648\u0644) \u0648\u0627\u0642\u0631\u0623 \u0642\u064a\u0645\u0629 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 (\u0641\u064a \u0646\u0637\u0627\u0642 \u0645\u0626\u0627\u062a \u0627\u0644\u0645\u064a\u062c\u0627 \u0623\u0648\u0645) \u062a\u0639\u0646\u064a \u0639\u0632\u0644 \u062c\u064a\u062f.<\/p><\/li><li><p>\u0642\u062f \u062a\u0634\u064a\u0631 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0623\u0648\u0633\u0627\u062e \u0623\u0648 \u062a\u0644\u0641 \u0641\u064a \u0627\u0644\u0639\u0632\u0644.<\/p><\/li><li><p>\u0627\u062a\u0628\u0639 \u062f\u0627\u0626\u0645\u064b\u0627 \u062c\u0647\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647 \u0645\u0646 \u0642\u0628\u0644 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0633\u062c\u0644 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u062a\u0646\u062e\u0641\u0636 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0645\u0639 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629.<\/p><\/blockquote>\n\n\n\n<p>\u064a\u062c\u0628 \u0625\u062c\u0631\u0627\u0621 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0643\u062c\u0632\u0621 \u0645\u0646 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0631\u0648\u062a\u064a\u0646\u064a\u0629 \u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u0641\u0647\u0648 \u064a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0639\u0632\u0644 \u0642\u0628\u0644 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0641\u064a \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0646\u0633\u0628\u0629 \u0627\u0644\u062f\u0648\u0631\u0627\u062a<\/h3>\n\n\n\n<p>\u064a\u062e\u062a\u0628\u0631 \u0627\u062e\u062a\u0628\u0627\u0631 \u0646\u0633\u0628\u0629 \u0627\u0644\u0644\u0641\u0627\u062a \u0646\u0633\u0628\u0629 \u0627\u0644\u0644\u0641\u0627\u062a \u0627\u0644\u0623\u0648\u0644\u064a\u0629 \u0625\u0644\u0649 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629. \u062a\u062d\u062f\u062f \u0647\u0630\u0647 \u0627\u0644\u0646\u0633\u0628\u0629 \u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u062c\u0647\u062f \u0644\u0644\u0648\u062d\u062f\u0629. \u062a\u0633\u062a\u062e\u062f\u0645 \u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u0646\u0633\u0628\u0629 \u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644 (TTR) \u0644\u0625\u062c\u0631\u0627\u0621 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631.<\/p>\n\n\n\n<p>\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 TTR \u0628\u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0623\u0648\u0644\u064a\u0629 \u0648\u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629. \u064a\u0642\u0648\u0645 \u062c\u0647\u0627\u0632 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u062a\u0637\u0628\u064a\u0642 \u062c\u0647\u062f \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0639\u0631\u0648\u0641 \u0639\u0644\u0649 \u0623\u062d\u062f \u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0648\u064a\u0642\u064a\u0633 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0644\u0649 \u0627\u0644\u0645\u0644\u0641 \u0627\u0644\u0622\u062e\u0631. \u062b\u0645 \u064a\u062d\u0633\u0628 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0646\u0633\u0628\u0629.<\/p>\n\n\n\n<p><strong>\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0646\u0633\u0628\u0629 \u0627\u0644\u062f\u0648\u0631\u0627\u0646:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0645\u0639\u0632\u0648\u0644 \u0648\u0622\u0645\u0646 \u0644\u0644\u0627\u062e\u062a\u0628\u0627\u0631.<\/p><\/li><li><p>\u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 TTR \u0648\u0641\u0642\u064b\u0627 \u0644\u062a\u0639\u0644\u064a\u0645\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u062c\u0645\u064a\u0639 \u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u0644\u0641.<\/p><\/li><li><p>\u0642\u0627\u0631\u0646 \u0627\u0644\u0646\u0633\u0628\u0629 \u0627\u0644\u0645\u0642\u0627\u0633\u0629 \u0628\u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0645\u0630\u0643\u0648\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0644\u0648\u062d\u0629.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u062a\u0624\u0643\u062f \u0646\u0633\u0628\u0629 \u0627\u0644\u0644\u0641\u0627\u062a \u0627\u0644\u0635\u062d\u064a\u062d\u0629 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0633\u064a\u0648\u0641\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0642\u0639. \u0642\u062f \u064a\u0634\u064a\u0631 \u0639\u062f\u0645 \u0627\u0644\u062a\u0637\u0627\u0628\u0642 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0644\u0641\u0627\u062a \u0642\u0635\u064a\u0631\u0629 \u0623\u0648 \u062a\u0648\u0635\u064a\u0644\u0627\u062a \u062e\u0627\u0637\u0626\u0629 \u0623\u0648 \u0639\u064a\u0648\u0628 \u0641\u064a \u0627\u0644\u062a\u0635\u0646\u064a\u0639.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u062a\u0630\u0643\u0631:<\/strong> \u0627\u062e\u062a\u0628\u0631 \u062f\u0627\u0626\u0645\u064b\u0627 \u062c\u0645\u064a\u0639 \u0623\u0648\u0636\u0627\u0639 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0645\u0632\u0648\u062f\u064b\u0627 \u0628\u0645\u0628\u062f\u0644\u0627\u062a \u0635\u0645\u0627\u0645\u0627\u062a. \u0647\u0630\u0627 \u064a\u0636\u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0633\u0644\u064a\u0645 \u0641\u064a \u062c\u0645\u064a\u0639 \u0627\u0644\u0625\u0639\u062f\u0627\u062f\u0627\u062a.<\/p><\/blockquote>\n\n\n\n<p>\u062a\u0634\u0643\u0644 \u0647\u0630\u0647 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062b\u0644\u0627\u062b\u0629 \u2014 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641\u060c \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644\u060c \u0648\u0646\u0633\u0628\u0629 \u0627\u0644\u0644\u0641\u0627\u062a \u2014 \u0623\u0633\u0627\u0633 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u0641\u0647\u064a \u062a\u0633\u0627\u0639\u062f\u0643 \u0641\u064a \u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0641\u064a\u0629\u060c \u0648\u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u060c \u0648\u0636\u0645\u0627\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0645\u0646.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0648\u0644\u0629<\/h3>\n\n\n\n<p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0642\u064a\u0627\u0633 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \u0644\u0644\u0645\u062d\u0648\u0644 \u0644\u0641\u0647\u0645 \u0643\u0641\u0627\u0621\u062a\u0647 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644. \u064a\u0648\u0636\u062d \u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \u0645\u0642\u062f\u0627\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u062a\u064a \u064a\u0641\u0642\u062f\u0647\u0627 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0644\u0649 \u0634\u0643\u0644 \u062d\u0631\u0627\u0631\u0629 \u0639\u0646\u062f\u0645\u0627 \u064a\u062d\u0645\u0644 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0645\u0642\u0646\u0646. \u064a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0644\u0649 \u062a\u0642\u064a\u064a\u0645 \u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u0645\u062d\u0648\u0644 \u0648\u0623\u062f\u0627\u0626\u0647 \u0627\u0644\u0639\u0627\u0645.<\/p>\n\n\n\n<p>\u0639\u0646\u062f \u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644\u060c \u062a\u0642\u0648\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0628\u0645\u0635\u062f\u0631 \u0637\u0627\u0642\u0629 \u0648\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646 \u0639\u0644\u0649 \u0627\u0644\u0644\u0641\u0627\u062a. \u062b\u0645 \u062a\u0642\u064a\u0633 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0630\u064a \u064a\u062d\u062f\u062b \u0628\u0633\u0628\u0628 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0641\u064a \u0627\u0644\u0644\u0641\u0627\u062a. \u064a\u064f\u0633\u0645\u0649 \u0647\u0630\u0627 \u0627\u0644\u0641\u0642\u062f\u0627\u0646 \u201c\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u0646\u062d\u0627\u0633\u201d \u0644\u0623\u0646\u0647 \u064a\u0623\u062a\u064a \u0628\u0634\u0643\u0644 \u0623\u0633\u0627\u0633\u064a \u0645\u0646 \u0627\u0644\u0644\u0641\u0627\u062a \u0627\u0644\u0646\u062d\u0627\u0633\u064a\u0629 \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0644\u0645\u0627\u0630\u0627 \u0647\u0630\u0627 \u0645\u0647\u0645:<\/strong> \u064a\u0639\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \u0623\u0645\u0631\u064b\u0627 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u062a\u0642\u064a\u064a\u0645 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0645\u062d\u0648\u0644. \u0641\u0647\u0648 \u064a\u062d\u062f\u062f \u0625\u062c\u0645\u0627\u0644\u064a \u0627\u0644\u062e\u0633\u0627\u0626\u0631 \u0627\u0644\u062a\u064a \u064a\u062a\u0643\u0628\u062f\u0647\u0627 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0646\u062f\u0645\u0627 \u064a\u0643\u0648\u0646 \u062a\u062d\u062a \u0627\u0644\u062d\u0645\u0644. \u0648\u0645\u0646 \u062e\u0644\u0627\u0644 \u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0647\u0630\u0647 \u0627\u0644\u062e\u0633\u0627\u0626\u0631\u060c \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0623\u0633\u0627\u0633\u064a\u0629 \u062d\u0648\u0644 \u0623\u062f\u0627\u0621 \u0627\u0644\u0645\u062d\u0648\u0644 \u0641\u064a \u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0641\u0639\u0644\u064a\u0629.<\/p><\/blockquote>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0648\u0644\u0629:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u063a\u064a\u0631 \u0645\u0632\u0648\u062f \u0628\u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0645\u0639\u0632\u0648\u0644.<\/p><\/li><li><p>\u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u062c\u0647\u0627\u0632 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0623\u0648\u0644\u064a\u0629 \u0648\u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629.<\/p><\/li><li><p>\u0642\u0645 \u0628\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646 \u0648\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0627\u0644\u062c\u0647\u062f \u0648\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u0637\u0627\u0642\u0629.<\/p><\/li><li><p>\u0633\u062c\u0644 \u0627\u0644\u0646\u062a\u0627\u0626\u062c \u0648\u0642\u0627\u0631\u0646\u0647\u0627 \u0628\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u062e\u0633\u0627\u0626\u0631 \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u0645\u062a\u0648\u0642\u0639\u060c \u0641\u0642\u062f \u062a\u0643\u0648\u0646 \u0647\u0646\u0627\u0643 \u0645\u0634\u0627\u0643\u0644 \u0645\u062b\u0644 \u0636\u0639\u0641 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0623\u0648 \u062a\u0644\u0641 \u0627\u0644\u0644\u0641\u0627\u062a \u0623\u0648 \u0639\u064a\u0648\u0628 \u0641\u064a \u0627\u0644\u062a\u0635\u0645\u064a\u0645. \u064a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0628\u0643\u0631 \u0639\u0644\u0649 \u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u062a\u062d\u0633\u064a\u0646 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0633\u0631\u0628<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u062a\u0633\u0631\u0628\u0627\u062a \u0641\u064a \u062e\u0632\u0627\u0646\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0644\u0645\u0646\u0639 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u0632\u064a\u062a \u0648\u0641\u0634\u0644 \u0627\u0644\u0639\u0632\u0644. \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0627\u0644\u062a\u0633\u0631\u0628\u0627\u062a \u0625\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0627\u0646\u062e\u0641\u0627\u0636 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u062d\u062a\u0649 \u0641\u0634\u0644 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0639\u062f\u0629 \u0637\u0631\u0642 \u0644\u0644\u0643\u0634\u0641 \u0639\u0646 \u0627\u0644\u062a\u0633\u0631\u0628\u0627\u062a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629:<\/strong> \u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u0645\u0633\u0627\u0645\u064a\u0631 \u0627\u0644\u062a\u062b\u0628\u064a\u062a \u0648\u0627\u0644\u062d\u0634\u064a\u0627\u062a \u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u0636\u063a\u0637 \u0648\u0627\u0644\u0639\u0632\u0645.<\/p><\/li><li><p><strong>\u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0628\u0627\u0644\u0623\u0634\u0639\u0629 \u062a\u062d\u062a \u0627\u0644\u062d\u0645\u0631\u0627\u0621:<\/strong> \u0627\u0628\u062d\u062b \u0639\u0646 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0627\u0644\u0633\u0627\u062e\u0646\u0629\u060c \u0648\u0627\u0644\u062a\u064a \u0642\u062f \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0648\u0635\u0644\u0627\u062a \u0645\u0641\u0643\u0648\u0643\u0629.<\/p><\/li><li><p><strong>\u0637\u0631\u0642 \u0627\u0644\u062a\u0646\u0638\u064a\u0641:<\/strong> \u0642\u0645 \u0628\u062a\u0646\u0638\u064a\u0641 \u0627\u0644\u0623\u0633\u0637\u062d \u0628\u0627\u0646\u062a\u0638\u0627\u0645 \u0644\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0641\u064a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0628\u064a\u0646 \u0627\u0644\u0645\u0631\u0627\u062d\u0644 \u0648\u0627\u0644\u0623\u0631\u0636 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0644\u0639\u0632\u0644.<\/p><\/li><li><p><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629:<\/strong> \u0642\u064a\u0627\u0633 \u062c\u0648\u062f\u0629 \u0627\u0644\u0639\u0632\u0644 \u0648\u062a\u0633\u0631\u0628 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u0623\u064a\u0636\u064b\u0627 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u062c\u0645\u0648\u0639\u0627\u062a \u0623\u062f\u0648\u0627\u062a \u0645\u062a\u062e\u0635\u0635\u0629\u060c \u0645\u062b\u0644 \u0645\u062c\u0645\u0648\u0639\u0629 \u0623\u062f\u0648\u0627\u062a \u0625\u0635\u0644\u0627\u062d \u0627\u0644\u062a\u0633\u0631\u0628\u0627\u062a \u0641\u064a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a Duromar\u00ae. \u062a\u0639\u0645\u0644 \u0647\u0630\u0647 \u0627\u0644\u0645\u062c\u0645\u0648\u0639\u0629 \u0639\u0644\u0649 \u0633\u062f \u0627\u0644\u062a\u0633\u0631\u0628\u0627\u062a \u0641\u064a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0645\u0632\u0648\u062f\u0629 \u0628\u0627\u0644\u0637\u0627\u0642\u0629 \u062f\u0648\u0646 \u0625\u064a\u0642\u0627\u0641 \u062a\u0634\u063a\u064a\u0644\u0647\u0627. \u0648\u0647\u064a \u062a\u0633\u062a\u062e\u062f\u0645 \u0628\u0648\u0644\u064a\u0645\u0631\u0627\u062a \u0633\u0631\u064a\u0639\u0629 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0648\u0645\u0639\u062c\u0648\u0646 \u0645\u0642\u0648\u0649 \u0628\u0627\u0644\u0633\u064a\u0631\u0627\u0645\u064a\u0643 \u0644\u0625\u0635\u0644\u0627\u062d \u0627\u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u0645\u0639\u0631\u0636\u0629 \u0644\u0644\u062a\u0633\u0631\u0628 \u0628\u0633\u0631\u0639\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u062a\u0633\u062c\u064a\u0644 \u0645\u0648\u0642\u0639 \u0648\u062d\u062c\u0645 \u0623\u064a \u062a\u0633\u0631\u0628\u0627\u062a \u062a\u062c\u062f\u0647\u0627. \u0639\u0627\u0644\u062c \u0627\u0644\u062a\u0633\u0631\u0628\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u0641\u0648\u0631 \u0644\u062a\u062c\u0646\u0628 \u0645\u0634\u0627\u0643\u0644 \u0623\u0643\u0628\u0631.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/h3>\n\n\n\n<p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0639\u0632\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629. \u062a\u0648\u0636\u062d \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u062f\u0649 \u0642\u062f\u0631\u0629 \u0627\u0644\u0639\u0632\u0644 \u0639\u0644\u0649 \u062a\u062d\u0645\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u062f\u0648\u0646 \u0623\u0646 \u064a\u062a\u0644\u0641.<\/p>\n\n\n\n<p>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u060c \u062a\u062a\u0637\u0644\u0628 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629 \u0642\u0648\u0629 \u0639\u0627\u0632\u0644\u0629 \u062f\u0646\u064a\u0627 \u062a\u0628\u0644\u063a \u062d\u0648\u0627\u0644\u064a <strong>30 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0644\u0643\u0644 \u0645\u0644\u064a\u0645\u062a\u0631<\/strong>. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f\u060c \u064a\u062c\u0628 \u0627\u0644\u0628\u062d\u062b \u0639\u0646 \u0642\u064a\u0645 <strong>50 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0644\u0643\u0644 \u0645\u0644\u064a\u0645\u062a\u0631<\/strong> \u0623\u0648 \u0623\u0639\u0644\u0649. \u062a\u0633\u0627\u0639\u062f \u0647\u0630\u0647 \u0627\u0644\u0642\u064a\u0645 \u0639\u0644\u0649 \u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0627\u062c\u0645\u0639 \u0639\u064a\u0646\u0629 \u0645\u0646 \u0627\u0644\u0632\u064a\u062a \u0645\u0646 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p><\/li><li><p>\u0627\u0633\u062a\u062e\u062f\u0645 \u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u062a\u0637\u0628\u064a\u0642 \u062c\u0647\u062f \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u062a\u0632\u0627\u064a\u062f \u0639\u0644\u0649 \u0627\u0644\u0639\u064a\u0646\u0629.<\/p><\/li><li><p>\u0633\u062c\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0630\u064a \u064a\u062d\u062f\u062b \u0639\u0646\u062f\u0647 \u0627\u0644\u0627\u0646\u0647\u064a\u0627\u0631.<\/p><\/li><li><p>\u0642\u0627\u0631\u0646 \u0627\u0644\u0646\u062a\u064a\u062c\u0629 \u0628\u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0627\u0646\u062e\u0641\u0627\u0636 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u064a\u0639\u0646\u064a \u0623\u0646 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0644\u0639\u0627\u0632\u0644 \u0642\u062f \u064a\u0643\u0648\u0646 \u0645\u0644\u0648\u062b\u064b\u0627 \u0628\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0627\u0644\u062c\u0633\u064a\u0645\u0627\u062a. \u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0639\u0627\u0644\u062c\u0647 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0644\u0627 \u064a\u0641\u064a \u0628\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629.<\/p><\/blockquote>\n\n\n\n<p>\u064a\u0633\u0627\u0639\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0627\u0643\u062a\u0634\u0627\u0641 \u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0639\u0632\u0644 \u0645\u0628\u0643\u0631\u0627\u064b \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0645\u0646 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL<\/h3>\n\n\n\n<p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL (\u0627\u0644\u062a\u0633\u0631\u0628 \u0644\u0643\u0644 \u0648\u062d\u062f\u0629) \u0639\u0646\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644 \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u062a\u0648\u0636\u062d \u0644\u0643 \u0647\u0630\u0647 \u0627\u0644\u0642\u064a\u0645\u0629 \u0645\u0642\u062f\u0627\u0631 \u0627\u0644\u0645\u0639\u0627\u0648\u0642\u0629 \u0627\u0644\u062a\u064a \u064a\u062a\u0645\u062a\u0639 \u0628\u0647\u0627 \u0627\u0644\u0645\u062d\u0648\u0644 \u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u0642\u064a\u0645\u062a\u0647 \u0627\u0644\u0645\u0642\u062f\u0631\u0629. \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u064a\u0637\u0644\u0642 \u0627\u0644\u0645\u0647\u0646\u062f\u0633\u0648\u0646 \u0639\u0644\u0649 \u0647\u0630\u0647 \u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0633\u0645 \u201c\u0646\u0633\u0628\u0629 \u0627\u0644\u0645\u0639\u0627\u0648\u0642\u0629\u201d \u0623\u0648 \u201c%Z\u201d. \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0647\u0630\u0627 \u0627\u0644\u0631\u0642\u0645 \u0639\u0644\u0649 \u0627\u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629 \u0644\u0644\u0645\u062d\u0648\u0644. \u0648\u0647\u0648 \u064a\u0644\u0639\u0628 \u062f\u0648\u0631\u064b\u0627 \u0631\u0626\u064a\u0633\u064a\u064b\u0627 \u0641\u064a \u0643\u064a\u0641\u064a\u0629 \u062a\u0639\u0627\u0645\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0645\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u062a\u0642\u0627\u0633\u0645 \u0627\u0644\u062d\u0645\u0644 \u0645\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0623\u062e\u0631\u0649.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0645\u0627 \u0647\u064a \u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL\u061f<\/h4>\n\n\n\n<p>\u062a\u064f\u0638\u0647\u0631 \u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL \u0646\u0633\u0628\u0629 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0633\u0631\u0628 \u0644\u0644\u0645\u062d\u0648\u0644 \u0625\u0644\u0649 \u0642\u064a\u0645\u062a\u0647 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629. \u0648\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u062a\u0638\u0647\u0631 \u0647\u0630\u0647 \u0627\u0644\u0646\u0633\u0628\u0629 \u0643\u0646\u0633\u0628\u0629 \u0645\u0626\u0648\u064a\u0629. \u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c \u0625\u0630\u0627 \u0643\u0627\u0646 \u0644\u0644\u0645\u062d\u0648\u0644 \u0645\u0642\u0627\u0648\u0645\u0629 5%\u060c \u0641\u0647\u0630\u0627 \u064a\u0639\u0646\u064a \u0623\u0646 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0639\u0628\u0631 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0646\u062f \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0643\u0627\u0645\u0644 \u064a\u0628\u0644\u063a 5% \u0645\u0646 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u062a\u0633\u0627\u0639\u062f\u0643 \u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL \u0639\u0644\u0649 \u062a\u0648\u0642\u0639 \u0645\u0642\u062f\u0627\u0631 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0639\u0646\u062f\u0645\u0627 \u064a\u062d\u0645\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u062a\u064a\u0627\u0631\u0647 \u0627\u0644\u0645\u0642\u0646\u0646. \u0643\u0645\u0627 \u0623\u0646\u0647\u0627 \u062a\u0624\u062b\u0631 \u0639\u0644\u0649 \u0645\u0642\u062f\u0627\u0631 \u062a\u064a\u0627\u0631 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0630\u064a \u0633\u064a\u062a\u062f\u0641\u0642 \u0623\u062b\u0646\u0627\u0621 \u062d\u062f\u0648\u062b \u0645\u0627\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0644\u0645\u0627\u0630\u0627 \u064a\u0639\u062a\u0628\u0631 PUL \u0645\u0647\u0645\u064b\u0627\u061f<\/h4>\n\n\n\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0641\u0647\u0645 \u0642\u064a\u0645\u0629 PUL \u0644\u0639\u062f\u0629 \u0623\u0633\u0628\u0627\u0628:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0642\u0635\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629:<\/strong> \u062a\u062d\u062f \u0642\u064a\u0645\u0629 PUL \u0627\u0644\u0623\u0639\u0644\u0649 \u0645\u0646 \u062a\u064a\u0627\u0631 \u0627\u0644\u0639\u0637\u0644 \u0623\u062b\u0646\u0627\u0621 \u062d\u062f\u0648\u062b \u0645\u0627\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0648\u0647\u0630\u0627 \u064a\u062d\u0645\u064a \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629.<\/p><\/li><li><p><strong>\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a:<\/strong> \u062a\u0624\u062f\u064a \u0642\u064a\u0645 PUL \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0625\u0644\u0649 \u062a\u0646\u0638\u064a\u0645 \u0623\u0641\u0636\u0644 \u0644\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0648\u0647\u0630\u0627 \u064a\u0639\u0646\u064a \u0623\u0646 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u064a\u0638\u0644 \u0623\u0643\u062b\u0631 \u0627\u0633\u062a\u0642\u0631\u0627\u0631\u064b\u0627 \u0639\u0646\u062f \u062a\u063a\u064a\u0631 \u0627\u0644\u062d\u0645\u0644.<\/p><\/li><li><p><strong>\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0648\u0627\u0632\u064a:<\/strong> \u0625\u0630\u0627 \u0642\u0645\u062a \u0628\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0627\u0644\u062a\u0648\u0627\u0632\u064a\u060c \u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0637\u0627\u0628\u0642 \u0642\u064a\u0645 PUL \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0647\u0627 \u0628\u0634\u0643\u0644 \u0648\u062b\u064a\u0642. \u0642\u062f \u062a\u0624\u062f\u064a \u0627\u0644\u0642\u064a\u0645 \u063a\u064a\u0631 \u0627\u0644\u0645\u062a\u0637\u0627\u0628\u0642\u0629 \u0625\u0644\u0649 \u062a\u0648\u0632\u064a\u0639 \u063a\u064a\u0631 \u0645\u062a\u0633\u0627\u0648\u064d \u0644\u0644\u062d\u0645\u0644 \u0648\u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0643\u064a\u0641\u064a\u0629 \u062a\u0623\u062b\u064a\u0631 PUL \u0639\u0644\u0649 \u0623\u062f\u0627\u0621 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0642\u064a\u0645\u0629 PUL (%)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u062a\u064a\u0627\u0631 \u0627\u0644\u0639\u0637\u0644<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0648\u0627\u0632\u064a<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636 (2-4%)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062c\u064a\u062f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062a\u0637\u0627\u0628\u0642 \u0648\u062b\u064a\u0642<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u062a\u0648\u0633\u0637 (5-7%)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0639\u062a\u062f\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0639\u062a\u062f\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0633\u0647\u0644 \u0641\u064a \u0627\u0644\u0645\u0637\u0627\u0628\u0642\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0627\u0644\u064a\u0629 (8%+)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0646\u062e\u0641\u0636<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0641\u0642\u064a\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0642\u062f \u064a\u062d\u062f \u0645\u0646 \u0627\u0644\u0645\u0634\u0627\u0631\u0643\u0629<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0643\u064a\u0641 \u062a\u062e\u062a\u0628\u0631 \u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL\u061f<\/h4>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u0642\u064a\u0627\u0633 \u0642\u064a\u0645\u0629 PUL \u0639\u0646 \u0637\u0631\u064a\u0642 \u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0639\u0627\u0648\u0642\u0629\u060c \u0648\u0627\u0644\u0630\u064a \u064a\u064f\u0633\u0645\u0649 \u0623\u064a\u0636\u064b\u0627 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629. \u0648\u0625\u0644\u064a\u0643 \u0643\u064a\u0641\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0645 \u0628\u0630\u0644\u0643:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0627\u0641\u0635\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0639\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0639\u0632\u0644\u0647.<\/p><\/li><li><p>\u0627\u062e\u062a\u0635\u0631 \u0627\u0644\u0645\u0644\u0641 \u0627\u0644\u062b\u0627\u0646\u0648\u064a.<\/p><\/li><li><p>\u0642\u0645 \u0628\u062a\u0637\u0628\u064a\u0642 \u062c\u0647\u062f \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646\u062e\u0641\u0636 \u0639\u0644\u0649 \u0627\u0644\u0645\u0644\u0641 \u0627\u0644\u0623\u0648\u0644\u064a.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062c\u0647\u062f \u062d\u062a\u0649 \u064a\u062a\u062f\u0641\u0642 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646 \u0641\u064a \u0627\u0644\u0644\u0641\u0627\u062a.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0627\u0644\u062c\u0647\u062f \u0648\u0627\u0644\u062a\u064a\u0627\u0631.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u062d\u0633\u0627\u0628 \u0627\u0644\u0645\u0639\u0627\u0648\u0642\u0629 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0647\u0630\u0647 \u0627\u0644\u0635\u064a\u063a\u0629:<\/p>\n\n\n\n<pre class=\"wp-block-code\">\n<code>%Z = (\u062c\u0647\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \/ \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646) \u00d7 100\n<\/code><\/pre>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0642\u0627\u0631\u0646 \u062f\u0627\u0626\u0645\u064b\u0627 \u0642\u064a\u0645\u0629 PUL \u0627\u0644\u0645\u0642\u0627\u0633\u0629 \u0628\u0642\u064a\u0645\u0629 \u0627\u0644\u0644\u0648\u062d\u0629. \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0645\u0642\u0627\u0633\u0629 \u0623\u0639\u0644\u0649 \u0623\u0648 \u0623\u0642\u0644 \u0628\u0643\u062b\u064a\u0631\u060c \u0641\u0642\u062f \u064a\u0643\u0648\u0646 \u0647\u0646\u0627\u0643 \u062a\u0644\u0641 \u0641\u064a \u0627\u0644\u0645\u0644\u0641 \u0623\u0648 \u0645\u0634\u0627\u0643\u0644 \u0641\u064a \u0627\u0644\u062a\u0648\u0635\u064a\u0644.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0645\u0627\u0630\u0627 \u062a\u0639\u0646\u064a \u0627\u0644\u0646\u062a\u0627\u0626\u062c\u061f<\/h4>\n\n\n\n<p>\u0625\u0630\u0627 \u0643\u0627\u0646 \u0642\u064a\u0627\u0633 PUL \u0645\u0637\u0627\u0628\u0642\u064b\u0627 \u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a\u060c \u0641\u0647\u0630\u0627 \u064a\u0639\u0646\u064a \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0641\u064a \u062d\u0627\u0644\u0629 \u062c\u064a\u062f\u0629. \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0642\u064a\u0645\u0629 \u0645\u0631\u062a\u0641\u0639\u0629 \u062c\u062f\u064b\u0627\u060c \u0641\u0642\u062f \u064a\u0643\u0648\u0646 \u0647\u0646\u0627\u0643 \u0642\u0635\u0631 \u0641\u064a \u0627\u0644\u062f\u0648\u0631\u0627\u062a \u0623\u0648 \u0627\u062a\u0635\u0627\u0644\u0627\u062a \u063a\u064a\u0631 \u0645\u062d\u0643\u0645\u0629. \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0642\u064a\u0645\u0629 \u0645\u0646\u062e\u0641\u0636\u0629 \u062c\u062f\u064b\u0627\u060c \u0641\u0642\u062f \u064a\u0643\u0648\u0646 \u0647\u0646\u0627\u0643 \u0645\u0644\u0641 \u063a\u064a\u0631 \u0645\u062a\u0635\u0644 \u0623\u0648 \u0639\u064a\u0628 \u0641\u064a \u0627\u0644\u062a\u0635\u0646\u064a\u0639.<\/p>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062a\u0633\u062c\u064a\u0644 \u0642\u064a\u0645\u0629 PUL \u0641\u064a \u062a\u0642\u0631\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643. \u064a\u0633\u0627\u0639\u062f\u0643 \u0630\u0644\u0643 \u0639\u0644\u0649 \u062a\u062a\u0628\u0639 \u0627\u0644\u062a\u063a\u064a\u064a\u0631\u0627\u062a \u0628\u0645\u0631\u0648\u0631 \u0627\u0644\u0648\u0642\u062a \u0648\u0627\u0644\u062a\u062e\u0637\u064a\u0637 \u0644\u0644\u0635\u064a\u0627\u0646\u0629.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u062a\u0630\u0643\u0631\u0647\u0627:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0624\u062b\u0631 \u0645\u0648\u0627\u0635\u0641\u0627\u062a PUL \u0639\u0644\u0649 \u062a\u064a\u0627\u0631 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u062a\u0646\u0638\u064a\u0645 \u0627\u0644\u062c\u0647\u062f \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0648\u0627\u0632\u064a.<\/p><\/li><li><p>\u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u062a\u062d\u0642\u0642 \u0645\u0646 \u0642\u064a\u0645\u0629 PUL \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0631\u0648\u062a\u064a\u0646\u064a\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a.<\/p><\/li><li><p>\u0627\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0646\u062a\u0627\u0626\u062c \u0644\u0636\u0645\u0627\u0646 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0634\u0643\u0644 \u0622\u0645\u0646 \u0648\u0645\u0648\u062b\u0648\u0642 \u0648\u0641\u0639\u0627\u0644.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u062a\u0630\u0643\u0631:<\/strong> \u064a\u0633\u0627\u0639\u062f\u0643 \u0627\u062e\u062a\u0628\u0627\u0631 PUL \u0627\u0644\u062f\u0642\u064a\u0642 \u0639\u0644\u0649 \u0645\u0646\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0646\u0638\u0627\u0645 \u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u062f\u064a\u0643.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b.webp\" alt=\"\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a\" class=\"wp-image-1587\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0635\u062f\u0631 \u0627\u0644\u0635\u0648\u0631\u0629: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">pexels<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a> \u0623\u062b\u0646\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u064a\u0633\u0627\u0639\u062f\u0643 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a \u0641\u064a \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0627\u0644\u062e\u0641\u064a\u0629 \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644. \u062a\u0628\u062d\u062b \u0639\u0646 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0648\u062a\u062e\u062a\u0628\u0631 \u0642\u0648\u0629 \u0627\u0644\u0632\u064a\u062a \u0648\u062a\u0642\u064a\u0633 \u0627\u0644\u0631\u0637\u0648\u0628\u0629. \u062a\u0645\u0646\u062d\u0643 \u0643\u0644 \u062e\u0637\u0648\u0629 \u0623\u062f\u0644\u0629 \u062d\u0648\u0644 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u063a\u0627\u0632 \u0627\u0644\u0645\u0630\u0627\u0628<\/h3>\n\n\n\n<p>\u064a\u062e\u0628\u0631\u0643 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u0645\u0630\u0627\u0628\u0629 (DGA) \u0628\u0645\u0627 \u064a\u062d\u062f\u062b \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u062d\u0648\u0644. \u0639\u0646\u062f \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644\u060c \u062a\u062a\u0634\u0643\u0644 \u063a\u0627\u0632\u0627\u062a \u0641\u064a \u0627\u0644\u0632\u064a\u062a. \u062a\u0642\u0648\u0645 \u0628\u062c\u0645\u0639 \u0639\u064a\u0646\u0629 \u0645\u0646 \u0627\u0644\u0632\u064a\u062a \u0648\u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0639\u062f\u0627\u062a \u062e\u0627\u0635\u0629 \u0644\u0642\u064a\u0627\u0633 \u0647\u0630\u0647 \u0627\u0644\u063a\u0627\u0632\u0627\u062a. \u064a\u0634\u064a\u0631 \u0643\u0644 \u063a\u0627\u0632 \u0625\u0644\u0649 \u0646\u0648\u0639 \u0645\u062e\u062a\u0644\u0641 \u0645\u0646 \u0627\u0644\u0645\u0634\u0627\u0643\u0644.<\/p>\n\n\n\n<p>\u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u062c\u062f\u0648\u0644 \u064a\u0648\u0636\u062d \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0648\u0645\u0627 \u062a\u0639\u0646\u064a\u0647 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0635\u062d\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u063a\u0627\u0632<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0645\u0624\u0634\u0631 \u0639\u0644\u0649 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0648\u0644<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0647\u064a\u062f\u0631\u0648\u062c\u064a\u0646 (H\u2082)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u064f\u0638\u0647\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a \u0648\u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0627\u0644\u0639\u0632\u0644.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u064a\u062b\u0627\u0646 (CH\u2084)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0648\u0636\u0639\u064a \u0623\u0648 \u0636\u0639\u0641 \u0627\u0644\u062f\u0648\u0631\u0629 \u0627\u0644\u062f\u0645\u0648\u064a\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0625\u064a\u062b\u0627\u0646 (C\u2082H\u2086)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0627\u0646\u0647\u064a\u0627\u0631 \u062d\u0631\u0627\u0631\u064a \u0644\u0644\u0632\u064a\u062a \u0639\u0646\u062f \u062f\u0631\u062c\u0627\u062a \u062d\u0631\u0627\u0631\u0629 \u0645\u0646\u062e\u0641\u0636\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0625\u064a\u062b\u064a\u0644\u064a\u0646 (C\u2082H\u2084)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0623\u0639\u0637\u0627\u0644 \u062d\u0631\u0627\u0631\u064a\u0629 \u062e\u0637\u064a\u0631\u0629\u060c \u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u062a\u0643\u0648\u0646 \u0641\u0648\u0642 300 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0623\u0633\u064a\u062a\u064a\u0644\u064a\u0646 (C\u2082H\u2082)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0623\u0639\u0637\u0627\u0644 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0645\u062b\u0644 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0641\u0648\u0642 700 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0648\u0644 \u0623\u0643\u0633\u064a\u062f \u0627\u0644\u0643\u0631\u0628\u0648\u0646 (CO)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0646\u062a\u062c \u0639\u0646 \u0627\u0644\u0627\u0646\u0647\u064a\u0627\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0639\u0632\u0644.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062b\u0627\u0646\u064a \u0623\u0643\u0633\u064a\u062f \u0627\u0644\u0643\u0631\u0628\u0648\u0646 (CO\u2082)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u064a\u0648\u0636\u062d \u0645\u062f\u0649 \u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632\u064a.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u0631\u062a\u0641\u0627\u0639 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u0623\u0633\u064a\u062a\u064a\u0644\u064a\u0646 \u0623\u0648 \u0627\u0644\u0625\u064a\u062b\u064a\u0644\u064a\u0646 \u064a\u0639\u0646\u064a \u0623\u0646\u0647 \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u0635\u0631\u0641 \u0628\u0633\u0631\u0639\u0629. \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0634\u064a\u0631 \u0647\u0630\u0647 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0623\u0639\u0637\u0627\u0644 \u062e\u0637\u064a\u0631\u0629.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0642\u062f\u0631\u062a\u0647 \u0639\u0644\u0649 \u0627\u0644\u0639\u0632\u0644 \u0636\u062f \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a. \u064a\u0633\u062a\u062e\u062f\u0645 \u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u062c\u0647\u062f \u0627\u0644\u0627\u0646\u0647\u064a\u0627\u0631 (BDV) \u0644\u0647\u0630\u0647 \u0627\u0644\u0645\u0647\u0645\u0629. \u064a\u0648\u0636\u062d \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u062f\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0630\u064a \u064a\u0645\u0643\u0646 \u0644\u0644\u0632\u064a\u062a \u062a\u062d\u0645\u0644\u0647 \u0642\u0628\u0644 \u0623\u0646 \u064a\u062a\u0644\u0641.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u062f\u0646\u064a\u0627 \u0627\u0644\u0622\u0645\u0646\u0629 \u0644\u0640 BDV \u0644\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0647\u064a <strong>30 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/strong>. \u062a\u0638\u0644 \u0647\u0630\u0647 \u0627\u0644\u0642\u064a\u0645\u0629 \u0643\u0645\u0627 \u0647\u064a \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0639\u0638\u0645 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u062c\u0647\u062f\u060c \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0623\u0646\u0638\u0645\u0629 11 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u064822 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0648132 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a.<\/p><\/li><li><p>\u062a\u0646\u0635 \u0645\u0639\u0627\u064a\u064a\u0631 IEC \u0639\u0644\u0649 \u0623\u0646 \u062c\u0647\u062f \u0627\u0644\u0627\u0646\u0647\u064a\u0627\u0631 \u0644\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u0642\u0644 \u0639\u0646 <strong>30 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0625\u0630\u0627 \u0641\u0634\u0644 \u0627\u0644\u0632\u064a\u062a \u0641\u064a \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0641\u0642\u062f \u064a\u0643\u0648\u0646 \u064a\u062d\u062a\u0648\u064a \u0639\u0644\u0649 \u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0623\u0648\u0633\u0627\u062e. \u064a\u062c\u0628 \u062a\u0646\u0638\u064a\u0641 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0633\u062a\u0628\u062f\u0627\u0644\u0647 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u062a\u0633\u062c\u064a\u0644 \u0642\u064a\u0645\u0629 BDV \u0641\u064a \u062a\u0642\u0631\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643. \u062a\u0639\u0646\u064a \u0642\u064a\u0645\u0629 BDV \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0623\u0646 \u0627\u0644\u0632\u064a\u062a \u0644\u0627 \u064a\u0645\u0643\u0646\u0647 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/h3>\n\n\n\n<p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/dry-type-transformer\/\">\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a> \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0634\u0627\u0643\u0644. \u0627\u0644\u0645\u0627\u0621 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0642\u062f\u0631\u0629 \u0627\u0644\u0632\u064a\u062a \u0639\u0644\u0649 \u0627\u0644\u0639\u0632\u0644. \u0643\u0645\u0627 \u0623\u0646\u0647 \u064a\u0636\u0639\u0641 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0648\u0631\u0642\u064a \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u062a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u062e\u0635\u0627\u0626\u0635 \u0627\u0644\u0639\u0627\u0632\u0644\u0629 \u0644\u0644\u0632\u064a\u062a. \u0648\u0647\u0630\u0627 \u064a\u062c\u0639\u0644 \u0627\u0644\u0639\u0632\u0644 \u0623\u0642\u0644 \u0641\u0639\u0627\u0644\u064a\u0629.<\/p><\/li><li><p>\u064a\u0624\u062f\u064a \u0627\u0631\u062a\u0641\u0627\u0639 \u0646\u0633\u0628\u0629 \u0627\u0644\u0645\u0627\u0621 \u0625\u0644\u0649 \u0625\u0636\u0639\u0627\u0641 \u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0644\u0639\u0632\u0644 \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632. \u0648\u0647\u0630\u0627 \u064a\u0632\u064a\u062f \u0645\u0646 \u062e\u0637\u0631 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644.<\/p><\/li><li><p>\u062a\u0642\u0648\u0645 \u062c\u0632\u064a\u0626\u0627\u062a \u0627\u0644\u0645\u0627\u0621 \u0628\u062a\u0641\u0643\u064a\u0643 \u0633\u0644\u0627\u0633\u0644 \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632. \u062a\u0624\u062f\u064a \u0647\u0630\u0647 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0625\u0644\u0649 \u062a\u0633\u0631\u064a\u0639 \u062a\u0644\u0641 \u0627\u0644\u0639\u0632\u0644 \u0648\u062a\u0642\u0644\u064a\u0644 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u0645\u0627\u0621 \u0641\u064a \u0627\u0644\u0632\u064a\u062a. \u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u0631\u0637\u0648\u0628\u0629 \u0632\u0627\u0626\u062f\u0629\u060c \u0641\u0623\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0633\u062a\u0628\u062f\u0627\u0644\u0647. \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u064a\u0633\u0627\u0639\u062f \u0639\u0644\u0649 \u0625\u0637\u0627\u0644\u0629 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u062a\u0630\u0643\u0631:<\/strong> \u064a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0645\u0646\u062a\u0638\u0645 \u0644\u0644\u0632\u064a\u062a \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0627\u0643\u0644 \u0641\u064a \u0648\u0642\u062a \u0645\u0628\u0643\u0631. \u0648\u0628\u0630\u0644\u0643 \u062a\u062d\u0645\u064a \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0646\u0638\u0627\u0645 \u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u062f\u064a\u0643.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0623\u062f\u0627\u0621 \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629<\/h2>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/\">\u0623\u0646\u0638\u0645\u0629 \u0648\u0638\u064a\u0641\u064a\u0629 \u0648\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0633\u0644\u0627\u0645\u0629<\/a> \u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0642\u0628\u0644 \u0625\u0639\u0627\u062f\u0629 \u062a\u0634\u063a\u064a\u0644\u0647. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0633\u064a\u062d\u0645\u064a \u0646\u0641\u0633\u0647 \u0648\u0627\u0644\u0634\u0628\u0643\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0623\u0648 \u0627\u0644\u0638\u0631\u0648\u0641 \u063a\u064a\u0631 \u0627\u0644\u0639\u0627\u062f\u064a\u0629. \u0631\u0643\u0632 \u0639\u0644\u0649 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0648\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0625\u0646\u0630\u0627\u0631.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/h3>\n\n\n\n<p>\u062a\u0639\u0645\u0644 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0643\u062e\u0637 \u062f\u0641\u0627\u0639 \u0623\u0648\u0644 \u0644\u0645\u062d\u0648\u0644\u0643. \u0641\u0647\u064a \u062a\u0643\u062a\u0634\u0641 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u062a\u0641\u0635\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0646 \u0627\u0644\u0634\u0628\u0643\u0629 \u0644\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u064a \u062a\u0644\u0641.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a<\/h4>\n\n\n\n<p>\u062a\u062d\u0645\u064a \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0645\u062d\u0648\u0644 \u0645\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0632\u0627\u0626\u062f<\/a> \u0648\u0627\u0644\u062a\u0645\u0627\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u064a\u062c\u0628 \u0641\u062d\u0635 \u0643\u0644 \u0645\u0635\u0647\u0631 \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u0622\u0643\u0644 \u0623\u0648 \u0627\u0644\u062a\u0644\u0641 \u0627\u0644\u0645\u0627\u062f\u064a. \u0627\u0633\u062a\u0628\u062f\u0644 \u0623\u064a \u0645\u0635\u0647\u0631 \u064a\u0628\u062f\u0648 \u062a\u0627\u0644\u0641\u064b\u0627 \u0623\u0648 \u0645\u062d\u062a\u0631\u0642\u064b\u0627. \u0627\u0633\u062a\u062e\u062f\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u0644\u0645\u0635\u0647\u0631 \u0630\u064a \u0627\u0644\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0635\u062d\u064a\u062d \u0643\u0645\u0627 \u0647\u0648 \u0645\u062d\u062f\u062f \u0645\u0646 \u0642\u0628\u0644 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629. \u0627\u062e\u062a\u0628\u0631 \u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0643\u0644 \u0645\u0635\u0647\u0631 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u062c\u0647\u0627\u0632 \u0642\u064a\u0627\u0633 \u0645\u062a\u0639\u062f\u062f \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646\u0647 \u0633\u064a\u0639\u0645\u0644 \u0639\u0646\u062f \u0627\u0644\u062d\u0627\u062c\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u062d\u062a\u0641\u0638 \u0628\u0641\u062a\u0627\u0626\u0644 \u0627\u062d\u062a\u064a\u0627\u0637\u064a\u0629 \u0641\u064a \u0645\u062a\u0646\u0627\u0648\u0644 \u0627\u0644\u064a\u062f. \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0633\u0631\u064a\u0639 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0623\u062b\u0646\u0627\u0621 \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0637\u0648\u0627\u0631\u0626.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a<\/h4>\n\n\n\n<p>\u062a\u0633\u062a\u0634\u0639\u0631 \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0638\u0631\u0648\u0641 \u063a\u064a\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0648\u062a\u0637\u0644\u0642 \u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0648\u0642\u0627\u0626\u064a\u0629. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u0643\u0644 \u0645\u0631\u062d\u0644 \u064a\u0639\u0645\u0644 \u062d\u0633\u0628 \u0627\u0644\u062a\u0635\u0645\u064a\u0645. \u0627\u062e\u062a\u0628\u0631 \u0627\u0644\u0645\u0631\u062d\u0644 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0645\u062d\u0627\u0643\u0627\u0629 \u0638\u0631\u0648\u0641 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0633\u062a\u062c\u0627\u0628\u062a\u0647. \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u0631\u062d\u0644 \u064a\u0642\u0648\u0645 \u0628\u0641\u0635\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0623\u0648 \u0625\u0631\u0633\u0627\u0644 \u0625\u0634\u0627\u0631\u0629 \u0625\u0646\u0630\u0627\u0631. \u0631\u0627\u062c\u0639 \u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u0645\u0631\u062d\u0644 \u0648\u0642\u0627\u0631\u0646\u0647\u0627 \u0628\u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647\u0627. \u0627\u0636\u0628\u0637 \u0627\u0644\u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u0623\u064a \u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u062a\u0623\u0631\u064a\u0636<\/h3>\n\n\n\n<p>\u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u0633\u0644\u064a\u0645 \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0645\u062d\u0648\u0644\u0643 \u0622\u0645\u0646\u0627\u064b \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0641\u0647\u0648 \u064a\u0648\u062c\u0647 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0639\u064a\u0628\u0629 \u0628\u0623\u0645\u0627\u0646 \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636\u060c \u0645\u0645\u0627 \u064a\u062d\u0645\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0627\u0644\u0623\u0634\u062e\u0627\u0635 \u0639\u0644\u0649 \u062d\u062f \u0633\u0648\u0627\u0621.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629<\/h4>\n\n\n\n<p>\u064a\u062c\u0628 \u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646\u0647 \u064a\u0641\u064a \u0628\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0633\u0644\u0627\u0645\u0629. \u0647\u0646\u0627\u0643 \u0639\u062f\u0629 \u0637\u0631\u0642 \u062a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u0627\u0644\u0642\u064a\u0627\u0645 \u0628\u0630\u0644\u0643:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0637\u0631\u064a\u0642\u0629 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0625\u0645\u0643\u0627\u0646\u0627\u062a:<\/strong> \u0636\u0639 \u0623\u0639\u0645\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u064a \u0627\u0644\u0623\u0631\u0636. \u0642\u0645 \u0628\u062d\u0642\u0646 \u0627\u0644\u062a\u064a\u0627\u0631 \u0648\u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0644\u062d\u0633\u0627\u0628 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629.<\/p><\/li><li><p><strong>\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u062b\u0628\u064a\u062a \u0628\u0627\u0644\u0645\u0634\u0628\u0643:<\/strong> \u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0642\u064a\u0627\u0633\u064b\u0627 \u0645\u0632\u0648\u062f\u064b\u0627 \u0628\u0645\u0634\u0628\u0643 \u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u062f\u0648\u0646 \u0641\u0635\u0644 \u0627\u0644\u0623\u0631\u0636\u064a\u0629. \u0647\u0630\u0647 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u064a \u062a\u0639\u0645\u0644 \u0628\u0627\u0644\u0641\u0639\u0644.<\/p><\/li><li><p><strong>\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u062b\u0644\u0627\u062b:<\/strong> \u0627\u0633\u062a\u062e\u062f\u0645 \u062b\u0644\u0627\u062b\u0629 \u0623\u0648\u062a\u0627\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0644\u0649 \u0645\u0633\u0627\u0641\u0627\u062a \u0645\u062e\u062a\u0644\u0641\u0629 \u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0628\u062f\u0642\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0645\u0642\u0627\u0633\u0629 \u0648\u0645\u0642\u0627\u0631\u0646\u062a\u0647\u0627 \u0628\u0627\u0644\u062d\u062f \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u060c \u0627\u0644\u0630\u064a \u0639\u0627\u062f\u0629 \u0645\u0627 \u064a\u0643\u0648\u0646 \u0623\u0642\u0644 \u0645\u0646 1 \u0623\u0648\u0645 \u0644\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629. \u0642\u062f \u062a\u0634\u064a\u0631 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0625\u0644\u0649 \u0636\u0639\u0641 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0623\u0648 \u0645\u0634\u0627\u0643\u0644 \u0641\u064a \u0627\u0644\u062a\u0631\u0628\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0625\u0646\u0630\u0627\u0631\u0627\u062a \u0648\u0627\u0644\u0631\u062d\u0644\u0627\u062a<\/h3>\n\n\n\n<p>\u062a\u0646\u0628\u0647\u0643 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0625\u0646\u0630\u0627\u0631 \u0648\u0622\u0644\u064a\u0627\u062a \u0627\u0644\u0642\u0637\u0639 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0645\u0634\u0627\u0643\u0644 \u0648\u062a\u0642\u0648\u0645 \u0628\u0641\u0635\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0646\u062f \u0627\u0644\u0636\u0631\u0648\u0631\u0629. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u0647\u0630\u0647 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0642\u0648\u0645 \u0645\u0631\u062d\u0644\u0627\u062a \u0645\u0631\u0627\u0642\u0628\u0629 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0637\u0639 (TCS) \u0628\u0645\u0631\u0627\u0642\u0628\u0629 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0637\u0639 \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0641\u064a \u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u0648\u0642\u0627\u062a.<\/p><\/li><li><p>\u064a\u062a\u0645 \u062a\u0646\u0634\u064a\u0637 \u0627\u0644\u0625\u0646\u0630\u0627\u0631\u0627\u062a \u0625\u0630\u0627 \u0627\u0643\u062a\u0634\u0641 \u0645\u0631\u062d\u0644 TCS \u0645\u0634\u0643\u0644\u0627\u062a \u0645\u062b\u0644 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0645\u0641\u062a\u0648\u062d\u0629 \u0623\u0648 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0625\u0645\u062f\u0627\u062f \u0623\u0648 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p><\/li><li><p>\u064a\u0639\u0645\u0644 \u0645\u0631\u062d\u0644 TCS \u0633\u0648\u0627\u0621 \u0643\u0627\u0646 \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0623\u0648 \u0627\u0644\u0625\u064a\u0642\u0627\u0641\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0627\u062e\u062a\u0628\u0631 \u0643\u0644 \u0648\u0638\u064a\u0641\u0629 \u0625\u0646\u0630\u0627\u0631 \u0648\u0625\u064a\u0642\u0627\u0641 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0645\u062d\u0627\u0643\u0627\u0629 \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0623\u0639\u0637\u0627\u0644. \u062a\u0623\u0643\u062f \u0645\u0646 \u0635\u062f\u0648\u0631 \u0635\u0648\u062a \u0627\u0644\u0625\u0646\u0630\u0627\u0631 \u0648\u0641\u0635\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0639\u0646\u062f \u0627\u0644\u062d\u0627\u062c\u0629. \u0633\u062c\u0644 \u0627\u0644\u0646\u062a\u0627\u0626\u062c \u0644\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0641\u064a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u062a\u0630\u0643\u0631:<\/strong> \u062a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u062f\u0648\u0631\u064a\u0629 \u0644\u0644\u0648\u0638\u0627\u0626\u0641 \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0645\u0628\u0643\u0631\u0627\u064b \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0628\u0623\u0645\u0627\u0646.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0644\u062a\u0648\u062b\u064a\u0642<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u0646\u062a\u0627\u0626\u062c<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062f\u0627\u0626\u0645\u064b\u0627 \u062a\u0633\u062c\u064a\u0644 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0628\u0637\u0631\u064a\u0642\u0629 \u0648\u0627\u0636\u062d\u0629 \u0648\u0645\u0646\u0638\u0645\u0629. \u062a\u0633\u0627\u0639\u062f\u0643 \u0627\u0644\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u062f\u0642\u064a\u0642\u0629 \u0639\u0644\u0649 \u062a\u062a\u0628\u0639 \u062d\u0627\u0644\u0629 \u0643\u0644 \u0645\u062d\u0648\u0644 \u0628\u0645\u0631\u0648\u0631 \u0627\u0644\u0648\u0642\u062a. \u0627\u0633\u062a\u062e\u062f\u0645 \u0633\u062c\u0644 \u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u064a\u0627\u0633\u064a \u0623\u0648 \u0646\u0645\u0648\u0630\u062c \u0631\u0642\u0645\u064a \u0644\u062a\u062f\u0648\u064a\u0646 \u062c\u0645\u064a\u0639 \u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0648\u0627\u0644\u0645\u0644\u0627\u062d\u0638\u0627\u062a \u0648\u0623\u064a \u0646\u062a\u0627\u0626\u062c \u063a\u064a\u0631 \u0639\u0627\u062f\u064a\u0629. \u0642\u0645 \u0628\u062a\u0636\u0645\u064a\u0646 \u0627\u0644\u062a\u0627\u0631\u064a\u062e \u0648\u0627\u0644\u0645\u0648\u0642\u0639 \u0648\u0623\u0633\u0645\u0627\u0621 \u0627\u0644\u0623\u0634\u062e\u0627\u0635 \u0627\u0644\u0630\u064a\u0646 \u0623\u062c\u0631\u0648\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a. \u0623\u0631\u0641\u0642 \u0635\u0648\u0631\u064b\u0627 \u0644\u0623\u064a \u0623\u0636\u0631\u0627\u0631 \u0623\u0648 \u0645\u0634\u0643\u0644\u0627\u062a \u062a\u062c\u062f\u0647\u0627 \u0623\u062b\u0646\u0627\u0621 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0641\u062d\u0635. \u062a\u0633\u0647\u0644 \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0627\u0644\u062c\u064a\u062f \u0645\u0642\u0627\u0631\u0646\u0629 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0648\u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u062a\u064a \u0642\u062f \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0645\u0634\u0643\u0644\u0627\u062a \u0645\u0633\u062a\u0642\u0628\u0644\u064a\u0629.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u062d\u062a\u0641\u0638 \u0628\u0633\u062c\u0644\u0627\u062a\u0643 \u0641\u064a \u0634\u0643\u0644 \u0631\u0642\u0645\u064a \u0648\u0648\u0631\u0642\u064a. \u062a\u0636\u0645\u0646 \u0644\u0643 \u0647\u0630\u0647 \u0627\u0644\u0645\u0645\u0627\u0631\u0633\u0629 \u0648\u062c\u0648\u062f \u0646\u0633\u062e\u0629 \u0627\u062d\u062a\u064a\u0627\u0637\u064a\u0629 \u0641\u064a \u062d\u0627\u0644\u0629 \u0641\u0642\u062f\u0627\u0646 \u0625\u062d\u062f\u0649 \u0627\u0644\u0646\u0633\u062e\u062a\u064a\u0646.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0627\u062a\u0628\u0627\u0639 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0639\u0646\u062f \u062a\u0648\u062b\u064a\u0642 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0639\u0644\u0649 \u0625\u062b\u0628\u0627\u062a \u0623\u0646 \u0639\u0645\u0644\u0643 \u064a\u0641\u064a \u0628\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u062c\u0648\u062f\u0629. \u0627\u062d\u0631\u0635 \u062f\u0627\u0626\u0645\u064b\u0627 \u0639\u0644\u0649 \u0627\u0644\u0631\u062c\u0648\u0639 \u0625\u0644\u0649 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u062d\u064a\u062d\u0629 \u0644\u0643\u0644 \u0646\u0648\u0639 \u0645\u0646 \u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0648\u0644\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0628\u0639\u0636 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0647\u0645\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0623\u0646 \u062a\u0639\u0631\u0641\u0647\u0627:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0642\u064a\u0627\u0633\u064a<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0648\u0635\u0641<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEC \/ EN 61558<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0639\u064a\u0627\u0631 \u0641\u062d\u0635 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0641\u064a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0634\u0647\u0627\u062f\u0629 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 (ENEC)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u0644\u0627\u0645\u0629 \u0634\u0647\u0627\u062f\u0629 \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0639\u0646\u062f \u0627\u062a\u0628\u0627\u0639 \u0647\u0630\u0647 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631\u060c \u0641\u0625\u0646\u0643 \u062a\u0633\u0627\u0639\u062f \u0634\u0631\u0643\u062a\u0643 \u0639\u0644\u0649 \u0627\u062c\u062a\u064a\u0627\u0632 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u062f\u0642\u064a\u0642 \u0648\u0627\u0644\u0648\u0641\u0627\u0621 \u0628\u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0642\u0627\u0646\u0648\u0646\u064a\u0629. \u0643\u0645\u0627 \u0623\u0646\u0643 \u062a\u0633\u0647\u0644 \u0639\u0644\u0649 \u0627\u0644\u0622\u062e\u0631\u064a\u0646 \u0641\u0647\u0645 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062c\u0631\u064a\u0647\u0627.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u062a\u0648\u0635\u064a\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/h3>\n\n\n\n<p>\u0628\u0639\u062f \u0627\u0644\u0627\u0646\u062a\u0647\u0627\u0621 \u0645\u0646 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/dry-type-transformer\/\">\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a>, \u060c \u064a\u062c\u0628 \u0623\u0646 \u062a\u0642\u062f\u0645 \u062a\u0648\u0635\u064a\u0627\u062a \u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0636\u062d\u0629. \u062a\u0633\u0627\u0639\u062f \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0627\u062a \u0641\u064a \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u062a\u0647. \u0641\u064a\u0645\u0627 \u064a\u0644\u064a \u0628\u0639\u0636 \u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0623\u0646 \u062a\u0642\u062a\u0631\u062d\u0647\u0627:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0642\u0645 \u0628\u0625\u062d\u0643\u0627\u0645 \u0631\u0628\u0637 \u062c\u0645\u064a\u0639 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644.<\/p><\/li><li><p>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d \u0648\u064a\u0645\u0643\u0646\u0647\u0627 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644.<\/p><\/li><li><p>\u0631\u0627\u0642\u0628 \u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0644\u062a\u062c\u0646\u0628 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0632\u0627\u0626\u062f \u0648\u0627\u0644\u062a\u0644\u0641 \u0627\u0644\u0645\u0628\u0643\u0631.<\/p><\/li><li><p>\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0648\u0635\u0627\u062a \u0631\u0648\u062a\u064a\u0646\u064a\u0629 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u062a\u0622\u0643\u0644 \u0623\u0648 \u062a\u0633\u0631\u0628 \u0644\u0644\u0632\u064a\u062a \u0623\u0648 \u062a\u0622\u0643\u0644.<\/p><\/li><li><p>\u062a\u0642\u064a\u064a\u0645 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a> \u0644\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0627\u0644\u062d\u0645\u0648\u0636\u0629 \u0648\u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a.<\/p><\/li><li><p>\u0642\u0645 \u0628\u0627\u0644\u062a\u0646\u0638\u064a\u0641 \u0648\u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0644\u0623\u062f\u0627\u0621.<\/p><\/li><li><p>\u0627\u0633\u062a\u062e\u062f\u0645 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0645\u062a\u0642\u062f\u0645\u0629 \u0645\u062b\u0644 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u0645\u0630\u0627\u0628\u0629 \u0648\u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0644\u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0627\u0644\u062e\u0641\u064a\u0629.<\/p><\/li><li><p>\u0627\u0641\u062d\u0635 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0628\u062d\u062b\u064b\u0627 \u0639\u0646 \u0627\u0644\u0634\u0642\u0648\u0642 \u0648\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0646\u0638\u0627\u0641\u062a\u0647\u0627.<\/p><\/li><li><p>\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u062a\u0639\u0645\u0644 \u0644\u0645\u0646\u0639 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629.<\/p><\/li><li><p>\u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0646\u0627\u0641\u062b \u0647\u0648\u0627\u0621 \u0645\u0646 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0627 \u062c\u0644 \u0644\u0645\u0646\u0639 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0625\u0644\u0649 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062f\u0648\u0631\u064a\u0629 \u0628\u0646\u0627\u0621\u064b \u0639\u0644\u0649 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0633\u062a\u0637\u064a\u0644 \u0645\u0646 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u062a\u0642\u0644\u0644 \u0645\u0646 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u063a\u064a\u0631 \u0627\u0644\u0645\u062a\u0648\u0642\u0639\u0629.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0646\u062a\u0627\u0626\u062c \u063a\u064a\u0631 \u0637\u0628\u064a\u0639\u064a\u0629<\/h3>\n\n\n\n<p>\u0639\u0646\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644 \u062a\u0648\u0632\u064a\u0639\u060c \u0642\u062f \u062a\u062c\u062f \u0646\u062a\u0627\u0626\u062c \u0644\u0627 \u062a\u062a\u0637\u0627\u0628\u0642 \u0645\u0639 \u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u0645\u062a\u0648\u0642\u0639\u0629. \u0642\u062f \u062a\u0634\u064a\u0631 \u0647\u0630\u0647 \u0627\u0644\u0646\u062a\u0627\u0626\u062c \u063a\u064a\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0645\u0634\u0627\u0643\u0644 \u062e\u0641\u064a\u0629 \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u062d\u0648\u0644. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u0644\u062a\u0635\u0631\u0641 \u0628\u0633\u0631\u0639\u0629 \u0639\u0646\u062f\u0645\u0627 \u062a\u0644\u0627\u062d\u0638 \u0634\u064a\u0626\u064b\u0627 \u063a\u064a\u0631 \u0639\u0627\u062f\u064a. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0628\u0639\u0636 \u0627\u0644\u0646\u062a\u0627\u0626\u062c \u063a\u064a\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0627\u0644\u0623\u0643\u062b\u0631 \u0634\u064a\u0648\u0639\u064b\u0627 \u0648\u0645\u0627 \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0641\u0639\u0644\u0647 \u062d\u064a\u0627\u0644\u0647\u0627:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0646\u062a\u064a\u062c\u0629 \u063a\u064a\u0631 \u0637\u0628\u064a\u0639\u064a\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0648\u0635\u0644\u0627\u062a \u0645\u0641\u0643\u0648\u0643\u0629 \u0623\u0648 \u0645\u062a\u0622\u0643\u0644\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0641\u062d\u0635 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0648\u0634\u062f\u0647\u0627<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0639\u064a\u0648\u0628 \u0627\u0644\u0639\u0632\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0639\u064a\u0648\u0628 \u0627\u0644\u0645\u062a\u0639\u0644\u0642\u0629 \u0628\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0631\u0627\u0642\u0628\u0629 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u062a\u062d\u0633\u064a\u0646 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u0628\u0631\u064a\u062f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0633\u0631\u0628 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0646\u0641\u064a\u0630 \u062a\u062f\u0627\u0628\u064a\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u0644\u0648\u062b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0646\u0638\u064a\u0641 \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0644\u0648\u062b\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0634\u0648\u0631\u062a\u0627\u062a Interturn<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062e\u0633\u0627\u0626\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u062e\u0633\u0627\u0626\u0631 \u0648\u062a\u0635\u062d\u064a\u062d\u0647\u0627<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0641\u062d\u0635 \u0648\u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0627\u0644\u062a\u0627\u0644\u0641\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0634\u064a\u062e\u0648\u062e\u0629 \u0627\u0644\u0639\u0632\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0642\u064a\u064a\u0645 \u062d\u0627\u0644\u0629 \u0627\u0644\u0639\u0632\u0644 \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644\u0647 \u0625\u0630\u0627 \u0644\u0632\u0645 \u0627\u0644\u0623\u0645\u0631<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062a\u0634\u0648\u0647 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0642\u064a\u064a\u0645 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0647\u064a\u0643\u0644 \u0648\u0625\u0635\u0644\u0627\u062d\u0647 \u062d\u0633\u0628 \u0627\u0644\u062d\u0627\u062c\u0629<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0639\u0646\u062f \u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0646\u062a\u0627\u0626\u062c \u063a\u064a\u0631 \u0637\u0628\u064a\u0639\u064a\u0629\u060c \u0642\u0645 \u0628\u0625\u0646\u0634\u0627\u0621 \u062a\u0642\u0631\u064a\u0631 \u0644\u062a\u062a\u0628\u0639 \u062a\u063a\u064a\u0631\u0627\u062a \u0627\u0644\u0623\u062f\u0627\u0621. \u0627\u0633\u062a\u062e\u062f\u0645 \u0623\u062f\u0648\u0627\u062a \u0627\u0644\u062a\u0634\u062e\u064a\u0635 \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u062f\u0649 \u062e\u0637\u0648\u0631\u0629 \u0627\u0644\u0645\u0634\u0643\u0644\u0629. \u062d\u0627\u0648\u0644 \u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u062f\u0642\u064a\u0642 \u0644\u0644\u062e\u0644\u0644 \u0648\u0642\u0631\u0631 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u062a\u0642\u064a\u064a\u062f \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n\n\n\n<p>\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u0633\u062a\u0644\u0627\u062d\u0638 \u0646\u0641\u0633 \u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0631\u0648\u062a\u064a\u0646\u064a\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a. \u0625\u0646 \u0645\u0639\u0631\u0641\u0629 \u0647\u0630\u0647 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u062a\u0633\u0627\u0639\u062f\u0643 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0629 \u0645\u0628\u0643\u0631\u064b\u0627 \u0648\u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0644\u0627\u0632\u0645\u0629. \u064a\u0648\u0636\u062d \u0627\u0644\u062c\u062f\u0648\u0644 \u0623\u062f\u0646\u0627\u0647 \u0627\u0644\u0623\u0633\u0628\u0627\u0628 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0641\u0634\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0645\u062f\u0649 \u062a\u0643\u0631\u0627\u0631 \u062d\u062f\u0648\u062b\u0647\u0627:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0633\u0628\u0628 \u0627\u0644\u0641\u0634\u0644<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0639\u062f\u062f \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0641\u0634\u0644<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0641\u0634\u0644 \u0627\u0644\u0639\u0632\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>92<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u062d\u0645\u0648\u0644\u0629 \u0627\u0644\u0632\u0627\u0626\u062f\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>30<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>70<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>21<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0644\u0648\u062b \u0627\u0644\u0646\u0641\u0637<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>20<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984.webp\" alt=\"\u0645\u062e\u0637\u0637 \u0634\u0631\u064a\u0637\u064a \u064a\u0648\u0636\u062d \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0623\u0643\u062b\u0631 \u0634\u064a\u0648\u0639\u064b\u0627 \u0641\u064a \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639\" class=\"wp-image-1588\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0641\u0634\u0644 \u0627\u0644\u0639\u0632\u0644 \u0647\u0648 \u0627\u0644\u0645\u0634\u0643\u0644\u0629 \u0627\u0644\u0623\u0643\u062b\u0631 \u0634\u064a\u0648\u0639\u064b\u0627 \u0627\u0644\u062a\u064a \u0633\u062a\u0648\u0627\u062c\u0647\u0647\u0627. \u0643\u0645\u0627 \u0623\u0646 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0632\u0627\u0626\u062f \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u064a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062a\u062a\u0633\u0628\u0628 \u0623\u064a\u0636\u064b\u0627 \u0641\u064a \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644. \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0627\u0644\u062a\u0644\u0648\u062b \u0628\u0627\u0644\u0632\u064a\u062a \u0625\u0644\u0649 \u0625\u0636\u0639\u0627\u0641 \u0627\u0644\u0639\u0632\u0644 \u0648\u062a\u0633\u0628\u0628 \u0623\u0639\u0637\u0627\u0644\u064b\u0627. \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062c\u0631\u064a\u0647\u0627.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0625\u0631\u0634\u0627\u062f\u0627\u062a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/h3>\n\n\n\n<p>\u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u0645\u0634\u0643\u0644\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0641\u0623\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0625\u0639\u0627\u062f\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644 \u0628\u0639\u062f \u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0625\u0635\u0644\u0627\u062d\u0627\u062a \u0623\u0648 \u0627\u0644\u062a\u0639\u062f\u064a\u0644\u0627\u062a. \u062a\u0633\u0627\u0639\u062f\u0643 \u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062c\u064a\u062f\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0622\u0645\u0646 \u0648\u062c\u0627\u0647\u0632 \u0644\u0644\u0639\u0645\u0644. \u0627\u062a\u0628\u0639 \u0647\u0630\u0647 \u0627\u0644\u0625\u0631\u0634\u0627\u062f\u0627\u062a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0627\u062d\u062a\u0641\u0638 \u0628\u0633\u062c\u0644 \u0645\u0641\u0635\u0644 \u0644\u062c\u0645\u064a\u0639 \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0648\u0623\u062f\u0627\u0621 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a. \u064a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0627 \u0627\u0644\u0633\u062c\u0644 \u0639\u0644\u0649 \u0627\u062a\u062e\u0627\u0630 \u0642\u0631\u0627\u0631\u0627\u062a \u0623\u0641\u0636\u0644 \u0641\u064a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644.<\/p><\/li><li><p>\u0627\u062e\u062a\u0628\u0631 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0642\u0628\u0644 \u0627\u0646\u062a\u0647\u0627\u0621 \u0641\u062a\u0631\u0629 \u0627\u0644\u0636\u0645\u0627\u0646. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u062e\u0637\u0648\u0629 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627 \u0641\u064a \u0648\u0642\u062a \u0645\u0628\u0643\u0631.<\/p><\/li><li><p>\u0627\u0633\u062a\u062e\u062f\u0645 \u0623\u062c\u0647\u0632\u0629 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0635\u062d\u0629 \u0644\u062a\u062a\u0628\u0639 \u0627\u0644\u0645\u0639\u0644\u0645\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0645\u062b\u0644 \u062c\u0648\u062f\u0629 \u0627\u0644\u0639\u0632\u0644 \u0648\u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629.<\/p><\/li><li><p>\u0627\u0633\u062a\u062e\u062f\u0645 \u0628\u0627\u0646\u062a\u0638\u0627\u0645 \u0623\u062f\u0648\u0627\u062a \u0627\u0644\u062a\u0634\u062e\u064a\u0635 \u0645\u062b\u0644 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u063a\u0627\u0632 \u0627\u0644\u0645\u0630\u0627\u0628 \u0648\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u0623\u062f\u0648\u0627\u062a \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0641\u064a\u0629 \u0648\u0627\u0644\u062a\u062e\u0637\u064a\u0637 \u0644\u0644\u0635\u064a\u0627\u0646\u0629.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u062a\u0633\u0627\u0639\u062f\u0643 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062f\u0642\u064a\u0642 \u0648\u062d\u0641\u0638 \u0627\u0644\u0633\u062c\u0644\u0627\u062a \u0641\u064a \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u062d\u0648\u0644\u0627\u062a \u0622\u0645\u0646\u0629 \u0648\u0645\u0648\u062b\u0648\u0642\u0629. \u0627\u062a\u0628\u0639 \u062f\u0627\u0626\u0645\u064b\u0627 \u0646\u0647\u062c\u064b\u0627 \u062a\u062f\u0631\u064a\u062c\u064a\u064b\u0627 \u0641\u064a \u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0623\u0641\u0636\u0644 \u0627\u0644\u0645\u0645\u0627\u0631\u0633\u0627\u062a<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u062a\u0633\u0644\u0633\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u062a\u0628\u0627\u0639 \u062a\u0633\u0644\u0633\u0644 \u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0636\u062d \u0623\u062b\u0646\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u064a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0627 \u0627\u0644\u0646\u0647\u062c \u0639\u0644\u0649 \u062a\u062c\u0646\u0628 \u0641\u0642\u062f\u0627\u0646 \u062e\u0637\u0648\u0627\u062a \u0645\u0647\u0645\u0629 \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u062a\u0646\u0638\u064a\u0645 \u0639\u0645\u0644\u0643. \u0627\u0628\u062f\u0623 \u0628\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a. \u0627\u0646\u062a\u0642\u0644 \u0625\u0644\u0649 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0627\u062e\u062a\u062a\u0645 \u0628\u0639\u0645\u0644\u064a\u0629 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a \u0648\u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0648\u0638\u064a\u0641\u064a\u0629. \u064a\u0645\u0643\u0646\u0643 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u062c\u0639\u064a\u0629 \u0644\u062a\u062a\u0628\u0639 \u062a\u0642\u062f\u0645\u0643.<\/p>\n\n\n\n<p><strong>\u062a\u0633\u0644\u0633\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a \u0644\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 \u0648\u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629<\/p><\/li><li><p>\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 (\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641\u060c \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644\u060c \u0646\u0633\u0628\u0629 \u0627\u0644\u0644\u0641\u0627\u062a)<\/p><\/li><li><p>\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a (\u0627\u0644\u063a\u0627\u0632 \u0627\u0644\u0645\u0630\u0627\u0628\u060c \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629)<\/p><\/li><li><p>\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0623\u062f\u0627\u0621 \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629 (\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629\u060c \u0627\u0644\u062a\u0623\u0631\u064a\u0636\u060c \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0625\u0646\u0630\u0627\u0631)<\/p><\/li>\n<\/ol>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0646\u0635\u064a\u062d\u0629:<\/strong> \u0627\u0644\u062a\u0632\u0645 \u0628\u0646\u0641\u0633 \u0627\u0644\u062a\u0633\u0644\u0633\u0644 \u0641\u064a \u0643\u0644 \u0645\u0631\u0629. \u0633\u0648\u0641 \u062a\u0643\u062a\u0634\u0641 \u0627\u0644\u0645\u0634\u0627\u0643\u0644 \u0645\u0628\u0643\u0631\u0627\u064b \u0648\u062a\u0642\u0644\u0644 \u0645\u0646 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0623\u062e\u0637\u0627\u0621.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0639\u0627\u064a\u0631\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a<\/h3>\n\n\n\n<p>\u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0646\u062a\u0627\u0626\u062c \u062f\u0642\u064a\u0642\u0629 \u0644\u0643\u0644 \u0627\u062e\u062a\u0628\u0627\u0631. \u062a\u0648\u0641\u0631 \u0644\u0643 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629 \u0628\u064a\u0627\u0646\u0627\u062a \u0645\u0648\u062b\u0648\u0642\u0629. \u0642\u0628\u0644 \u0627\u0644\u0628\u062f\u0621\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u0634\u0647\u0627\u062f\u0627\u062a \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629 \u0644\u062c\u0645\u064a\u0639 \u0623\u062c\u0647\u0632\u062a\u0643. \u0627\u0646\u0638\u0631 \u0625\u0644\u0649 \u0627\u0644\u062a\u0627\u0631\u064a\u062e \u0648\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u062a\u0641\u064a \u0628\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629. \u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u0634\u0647\u0627\u062f\u0627\u062a \u0645\u0646\u062a\u0647\u064a\u0629 \u0627\u0644\u0635\u0644\u0627\u062d\u064a\u0629\u060c \u0623\u0631\u0633\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0644\u0644\u0645\u0639\u0627\u064a\u0631\u0629.<\/p>\n\n\n\n<p><strong>\u062c\u062f\u0648\u0644 \u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0645\u0639\u062f\u0627\u062a<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0641\u062a\u0631\u0629 \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0627\u0644\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0645\u0637\u0644\u0648\u0628<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0643\u0644 6 \u0623\u0634\u0647\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0634\u0647\u0627\u062f\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0645\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0641<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0643\u0644 12 \u0634\u0647\u0631\u0627\u064b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062f\u0642\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u0646\u0633\u0628\u0629 \u0627\u0644\u062f\u0648\u0631\u0627\u0646<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0643\u0644 12 \u0634\u0647\u0631\u0627\u064b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u062a\u0623\u0643\u064a\u062f \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0627\u062e\u062a\u0628\u0627\u0631 BDV \u0644\u0644\u0632\u064a\u062a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0643\u0644 6 \u0623\u0634\u0647\u0631<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0641\u062d\u0635 \u0648\u0645\u0639\u0627\u064a\u0631\u0629<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> \u064a\u062c\u0628 \u0639\u062f\u0645 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0639\u062f\u0627\u062a \u063a\u064a\u0631 \u0645\u0639\u0627\u064a\u0631\u0629 \u0623\u0628\u062f\u064b\u0627. \u0641\u0642\u062f \u062a\u0624\u062f\u064a \u0627\u0644\u0642\u0631\u0627\u0621\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u062f\u0642\u064a\u0642\u0629 \u0625\u0644\u0649 \u0627\u062a\u062e\u0627\u0630 \u0642\u0631\u0627\u0631\u0627\u062a \u062e\u0627\u0637\u0626\u0629 \u0648\u0638\u0631\u0648\u0641 \u063a\u064a\u0631 \u0622\u0645\u0646\u0629.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0641\u0631\u064a\u0642<\/h3>\n\n\n\n<p>\u0627\u0644\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062c\u064a\u062f \u0628\u064a\u0646 \u0623\u0639\u0636\u0627\u0621 \u0627\u0644\u0641\u0631\u064a\u0642 \u064a\u062c\u0639\u0644 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0623\u0643\u062b\u0631 \u0623\u0645\u0627\u0646\u064b\u0627 \u0648\u0643\u0641\u0627\u0621\u0629. \u0642\u0645 \u0628\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0623\u062f\u0648\u0627\u0631 \u0628\u0648\u0636\u0648\u062d \u0639\u0644\u0649 \u0643\u0644 \u0639\u0636\u0648 \u0645\u0646 \u0623\u0639\u0636\u0627\u0621 \u0627\u0644\u0641\u0631\u064a\u0642. \u0642\u0645 \u0628\u0625\u0628\u0644\u0627\u063a\u0647\u0645 \u0628\u062e\u0637\u062a\u0643 \u0642\u0628\u0644 \u0627\u0644\u0628\u062f\u0621. \u0639\u0642\u062f \u0627\u062c\u062a\u0645\u0627\u0639\u064b\u0627 \u0644\u062a\u0648\u0636\u064a\u062d \u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0631\u0627\u062c\u0639 \u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0645\u0639\u0647\u0645. \u0627\u0633\u062a\u062e\u062f\u0645 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0631\u0627\u062f\u064a\u0648 \u0623\u0648 \u0627\u0644\u0647\u0648\u0627\u062a\u0641 \u0627\u0644\u0645\u062d\u0645\u0648\u0644\u0629 \u0644\u0644\u0628\u0642\u0627\u0621 \u0639\u0644\u0649 \u0627\u062a\u0635\u0627\u0644 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631.<\/p>\n\n\n\n<p><strong>\u0646\u0635\u0627\u0626\u062d \u0644\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0641\u0631\u064a\u0642:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u062a\u0639\u064a\u064a\u0646 \u0634\u062e\u0635 \u0648\u0627\u062d\u062f \u0644\u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u0646\u062a\u0627\u0626\u062c<\/p><\/li><li><p>\u062a\u0639\u064a\u064a\u0646 \u0645\u0633\u0624\u0648\u0644 \u0633\u0644\u0627\u0645\u0629 \u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0645\u062e\u0627\u0637\u0631<\/p><\/li><li><p>\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u062c\u0645\u064a\u0639 \u0639\u0644\u0649 \u0639\u0644\u0645 \u0628\u062a\u0633\u0644\u0633\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/p><\/li><li><p>\u0634\u0627\u0631\u0643 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u0627\u062a \u0648\u0627\u0644\u0646\u062a\u0627\u0626\u062c \u0645\u0639 \u0627\u0644\u0641\u0631\u064a\u0642 \u0628\u0623\u0643\u0645\u0644\u0647<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\ud83d\udee1\ufe0f \u062a\u062a\u062d\u0633\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0639\u0646\u062f\u0645\u0627 \u064a\u062f\u0631\u0643 \u0627\u0644\u062c\u0645\u064a\u0639 \u0645\u0633\u0624\u0648\u0644\u064a\u0627\u062a\u0647\u0645. \u064a\u0645\u0643\u0646\u0643 \u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0634\u0643\u0644 \u0623\u0633\u0631\u0639.<\/p><\/blockquote>\n\n\n\n<p>\u064a\u0645\u0643\u0646\u0643 \u062a\u062d\u0633\u064a\u0646 \u0646\u062a\u0627\u0626\u062c\u0643 \u0628\u0627\u062a\u0628\u0627\u0639 \u0645\u0627 \u064a\u0644\u064a <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/\">\u0623\u0641\u0636\u0644 \u0627\u0644\u0645\u0645\u0627\u0631\u0633\u0627\u062a<\/a>. \u0633\u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0641\u0631\u064a\u0642\u0643\u060c \u0648\u0633\u062a\u062d\u0635\u0644 \u0639\u0644\u0649 \u0628\u064a\u0627\u0646\u0627\u062a \u062f\u0642\u064a\u0642\u0629\u060c \u0648\u0633\u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a.<\/p>\n\n\n\n<p>\u062a\u062d\u0635\u0644 \u0639\u0644\u0649 \u0642\u064a\u0645\u0629 \u062d\u0642\u064a\u0642\u064a\u0629 \u0639\u0646\u062f\u0645\u0627 \u062a\u062a\u0628\u0639 \u0646\u0647\u062c\u064b\u0627 \u0645\u0646\u0647\u062c\u064a\u064b\u0627 \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u062a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0647 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0641\u064a \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0623\u0645\u0627\u0646\u0647\u0627 \u0648\u062a\u0648\u0627\u0641\u0642\u0647\u0627 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629. \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0628\u0642\u0627\u0621 \u0639\u0644\u0649 \u0627\u0637\u0644\u0627\u0639 \u0628\u0623\u0641\u0636\u0644 \u0627\u0644\u0645\u0645\u0627\u0631\u0633\u0627\u062a\u060c \u0641\u0625\u0646\u0643 \u062a\u062d\u0645\u064a \u0645\u0639\u062f\u0627\u062a\u0643 \u0648\u0641\u0631\u064a\u0642\u0643. \u0627\u0633\u062a\u0645\u0631 \u0641\u064a \u0627\u0644\u062a\u0639\u0644\u0645 \u0648\u0627\u062a\u0628\u0639 \u062f\u0627\u0626\u0645\u064b\u0627 \u0623\u062d\u062f\u062b \u0627\u0644\u0625\u0631\u0634\u0627\u062f\u0627\u062a. \u0625\u0646 \u0627\u0644\u062a\u0632\u0627\u0645\u0643 \u0628\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062c\u0648\u062f\u0629 \u064a\u062f\u0639\u0645 \u0634\u0628\u0643\u0629 \u0643\u0647\u0631\u0628\u0627\u0621 \u0623\u0642\u0648\u0649 \u0648\u0623\u0643\u062b\u0631 \u0623\u0645\u0627\u0646\u064b\u0627.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0627 \u0647\u0648 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0623\u0643\u062b\u0631 \u0623\u0647\u0645\u064a\u0629 \u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u061f<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062f\u0627\u0626\u0645\u064b\u0627 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0623\u0648\u0644\u0627\u064b. \u064a\u0633\u0627\u0639\u062f\u0643 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u064a \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0641\u064a \u0627\u0644\u0639\u0632\u0644. \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u062c\u064a\u062f \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u062a\u0647.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0643\u0645 \u0645\u0631\u0629 \u064a\u062c\u0628 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644 \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u061f<\/h3>\n\n\n\n<p>\u064a\u062c\u0628 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0631\u0629 \u0648\u0627\u062d\u062f\u0629 \u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0644 \u0641\u064a \u0627\u0644\u0633\u0646\u0629. \u0625\u0630\u0627 \u0644\u0627\u062d\u0638\u062a \u0648\u062c\u0648\u062f \u0645\u0634\u0627\u0643\u0644 \u0623\u0648 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u062a\u0639\u0645\u0644 \u0641\u064a \u0638\u0631\u0648\u0641 \u0642\u0627\u0633\u064a\u0629\u060c \u0641\u0642\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0634\u0643\u0644 \u0623\u0643\u062b\u0631 \u062a\u0643\u0631\u0627\u0631\u064b\u0627.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0644\u0645\u0627\u0630\u0627 \u064a\u0639\u062a\u0628\u0631 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a \u0645\u0647\u0645\u064b\u0627\u061f<\/h3>\n\n\n\n<p>\u064a\u0633\u0627\u0639\u062f\u0643 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0632\u064a\u062a \u0641\u064a \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0641\u064a\u0629. \u064a\u0645\u0643\u0646\u0643 \u0627\u0643\u062a\u0634\u0627\u0641 \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0633\u062e\u0648\u0646\u0629 \u0627\u0644\u0632\u0627\u0626\u062f\u0629 \u0623\u0648 \u062d\u062f\u0648\u062b \u0634\u0631\u0627\u0631\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0623\u0648 \u0627\u0644\u0631\u0637\u0648\u0628\u0629. \u064a\u062d\u0645\u064a \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0646\u0638\u064a\u0641 \u0627\u0644\u0645\u062d\u0648\u0644 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0627\u0630\u0627 \u064a\u062c\u0628 \u0623\u0646 \u062a\u0641\u0639\u0644 \u0625\u0630\u0627 \u0648\u062c\u062f\u062a \u062a\u0633\u0631\u0628\u064b\u0627 \u0644\u0644\u0632\u064a\u062a\u061f<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u062a\u0635\u0631\u0641 \u0628\u0633\u0631\u0639\u0629. \u0633\u062c\u0644 \u0645\u0648\u0642\u0639 \u0627\u0644\u062a\u0633\u0631\u0628 \u0648\u062d\u062c\u0645\u0647. \u0623\u0635\u0644\u062d \u0627\u0644\u062a\u0633\u0631\u0628 \u0648\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0632\u064a\u062a. \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062a\u0633\u0628\u0628 \u0627\u0644\u062a\u0633\u0631\u0628 \u0641\u064a \u0641\u0634\u0644 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0648\u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0647\u0644 \u064a\u0645\u0643\u0646\u0643 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u062b\u0646\u0627\u0621 \u062a\u0634\u063a\u064a\u0644\u0647\u061f<\/h3>\n\n\n\n<p>\u0644\u0627\u060c \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u0641\u0635\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0639\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0642\u0628\u0644 \u0625\u062c\u0631\u0627\u0621 \u0645\u0639\u0638\u0645 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a. \u0647\u0630\u0627 \u064a\u0636\u0645\u0646 \u0633\u0644\u0627\u0645\u062a\u0643 \u0648\u064a\u062d\u0645\u064a \u0645\u0639\u062f\u0627\u062a\u0643 \u0645\u0646 \u0627\u0644\u062a\u0644\u0641.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0645\u0627\u0630\u0627 \u062a\u0639\u0646\u064a \u0642\u064a\u0645\u0629 \u0642\u0648\u0629 \u0639\u0627\u0632\u0644\u0629 \u0645\u0646\u062e\u0641\u0636\u0629\u061f<\/h3>\n\n\n\n<p>\u062a\u0634\u064a\u0631 \u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0625\u0644\u0649 \u0627\u062d\u062a\u0645\u0627\u0644 \u0648\u062c\u0648\u062f \u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0623\u0648\u0633\u0627\u062e \u0641\u064a \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0644\u0639\u0627\u0632\u0644. \u064a\u062c\u0628 \u062a\u0646\u0638\u064a\u0641 \u0627\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0633\u062a\u0628\u062f\u0627\u0644\u0647 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u062d\u0648\u0644.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0643\u064a\u0641 \u062a\u0639\u0631\u0641 \u0623\u0646 \u0627\u0644\u0628\u0637\u0627\u0646\u0629 \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644\u061f<\/h3>\n\n\n\n<p>\u0627\u0628\u062d\u062b \u0639\u0646 \u0627\u0644\u0634\u0642\u0648\u0642 \u0623\u0648 \u0627\u0644\u0643\u0633\u0648\u0631 \u0623\u0648 \u0627\u0644\u062a\u0644\u0648\u062b. \u0625\u0630\u0627 \u0644\u0627\u062d\u0638\u062a \u0648\u062c\u0648\u062f \u062a\u0644\u0641\u060c \u0641\u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0628\u0637\u0627\u0646\u0629 \u0639\u0644\u0649 \u0627\u0644\u0641\u0648\u0631. \u0642\u062f \u062a\u062a\u0633\u0628\u0628 \u0627\u0644\u0628\u0637\u0627\u0646\u0627\u062a \u0627\u0644\u062a\u0627\u0644\u0641\u0629 \u0641\u064a \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0627\u062a\u0628\u0639 \u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0647\u0630\u0647 \u0644\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0644\u0636\u0645\u0627\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629 \u0641\u064a \u0643\u0644 \u0627\u062e\u062a\u0628\u0627\u0631.<\/p>","protected":false},"author":3,"featured_media":1585,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-1589","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/1589","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=1589"}],"version-history":[{"count":3,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/1589\/revisions"}],"predecessor-version":[{"id":3517,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/1589\/revisions\/3517"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/1585"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=1589"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=1589"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=1589"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}