{"id":2386,"date":"2025-12-31T12:52:57","date_gmt":"2025-12-31T12:52:57","guid":{"rendered":"https:\/\/xbrele.com\/?p=2386"},"modified":"2026-05-25T15:17:45","modified_gmt":"2026-05-25T15:17:45","slug":"top-10-vacuum-contactor-manufacturers-guide","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/top-10-vacuum-contactor-manufacturers-guide\/","title":{"rendered":"\u0623\u0641\u0636\u0644 10 \u0634\u0631\u0643\u0627\u062a \u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 (\u0635\u0646\u0627\u0639\u064a\u0629 + \u062a\u0639\u062f\u064a\u0646 + \u062f\u0644\u0627\u0621 OEM)"},"content":{"rendered":"\ufeff\n<p>\u0625\u0646 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0644\u064a\u0633 \u0642\u0631\u0627\u0631\u064b\u0627 \u0633\u0644\u0639\u064a\u064b\u0627. \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062e\u062a\u0644\u0641 \u0627\u062b\u0646\u0627\u0646 \u0645\u0646 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0641\u0629 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 400 \u0623\u0645\u0628\u064a\u0631\u060c AC-4 \u0628\u0645\u0639\u0627\u0645\u0644 \u062b\u0644\u0627\u062b\u0629 \u0641\u064a \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u0648\u064a\u0638\u0647\u0631\u0627\u0646 \u0645\u0639\u062f\u0644\u0627\u062a \u062a\u0622\u0643\u0644 \u062a\u0644\u0627\u0645\u0633 \u0645\u062a\u0641\u0627\u0648\u062a\u0629 40%\u060c \u0648\u064a\u0634\u062d\u0646\u0627\u0646 \u0628\u062c\u0648\u062f\u0629 \u0648\u062b\u0627\u0626\u0642 \u062a\u062a\u0631\u0627\u0648\u062d \u0628\u064a\u0646 \u201c\u0634\u0647\u0627\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0643\u0627\u0645\u0644\u201d \u0648\u201c\u062b\u0642 \u0628\u0646\u0627\u060c \u0625\u0646\u0647\u0627 \u062a\u0639\u0645\u0644\u201d. \u0648\u062a\u0638\u0647\u0631 \u0647\u0630\u0647 \u0627\u0644\u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u0628\u0639\u062f 18 \u0634\u0647\u0631\u064b\u0627 \u0645\u0646 \u0627\u0644\u062e\u062f\u0645\u0629 - \u0628\u0639\u062f \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0644\u0648\u062d\u0629 \u0648\u0628\u0639\u062f \u0627\u0646\u062a\u0647\u0627\u0621 \u0641\u062a\u0631\u0629 \u0636\u0645\u0627\u0646 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0648\u0628\u0639\u062f \u0623\u0646 \u062a\u0635\u0628\u062d \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0645\u0634\u0643\u0644\u0629 \u0627\u0644\u0645\u0646\u0634\u0623\u0629.<\/p>\n\n\n\n<p>\u064a\u0646\u0642\u0633\u0645 \u0633\u0648\u0642 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0625\u0644\u0649 \u062b\u0644\u0627\u062b\u0629 \u0642\u0637\u0627\u0639\u0627\u062a: \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 \u0630\u0627\u062a \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u0645\u0645\u062a\u0627\u0632\u0629 \u0648\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0634\u0627\u0645\u0644\u060c \u0648\u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u0648\u0646 \u0627\u0644\u0630\u064a\u0646 \u064a\u0642\u062f\u0645\u0648\u0646 \u0623\u0633\u0639\u0627\u0631\u064b\u0627 \u062a\u0646\u0627\u0641\u0633\u064a\u0629 \u0645\u0639 \u0645\u0631\u0627\u0642\u0628\u0629 \u062c\u0648\u062f\u0629 \u0645\u062a\u063a\u064a\u0631\u0629\u060c \u0648\u0627\u0644\u0645\u0648\u0631\u062f\u0648\u0646 \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0648\u0646 \u0641\u064a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0627\u0644\u0630\u064a\u0646 \u064a\u0631\u0643\u0632\u0648\u0646 \u0639\u0644\u0649 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062d\u062c\u0645 \u0627\u0644\u0643\u0628\u064a\u0631. \u062a\u062e\u062f\u0645 \u0643\u0644 \u0641\u0626\u0629 \u0627\u062d\u062a\u064a\u0627\u062c\u0627\u062a \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0646 \u0627\u0644\u0645\u062a\u0645\u064a\u0632\u0629\u060c \u0648\u062a\u062d\u062f\u062f \u0645\u0637\u0627\u0628\u0642\u0629 \u0642\u062f\u0631\u0629 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0639 \u0623\u0647\u0645\u064a\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u062f\u0649 \u0627\u0644\u0637\u0648\u064a\u0644 \u0623\u0643\u062b\u0631 \u0645\u0646 \u0633\u0639\u0631 \u0627\u0644\u0634\u0631\u0627\u0621 \u0627\u0644\u0623\u0648\u0644\u064a.<\/p>\n\n\n\n<p>\u064a\u0642\u064a\u0651\u0645 \u0647\u0630\u0627 \u0627\u0644\u062f\u0644\u064a\u0644 10 \u0634\u0631\u0643\u0627\u062a \u0645\u0635\u0646\u0639\u0629 \u0639\u0628\u0631 \u0623\u0631\u0628\u0639 \u0641\u0626\u0627\u062a: \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u0648\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u062c\u0648\u062f\u0629 \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u0641\u0646\u064a\u0629\u060c \u0648\u062a\u0648\u0627\u0641\u0631 \u0627\u0644\u062e\u062f\u0645\u0629 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629. \u0648\u064a\u0639\u0637\u064a \u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 (\u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0627\u0644\u0645\u064a\u0627\u0647\/\u0645\u064a\u0627\u0647 \u0627\u0644\u0635\u0631\u0641 \u0627\u0644\u0635\u062d\u064a \u0648\u0627\u0644\u062a\u0643\u064a\u064a\u0641) \u0648\u062a\u0643\u0627\u0645\u0644 \u0644\u0648\u062d\u0627\u062a \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 - \u0648\u0644\u064a\u0633 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u062d\u064a\u062b \u062a\u0647\u064a\u0645\u0646 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0641\u0631\u063a\u0629.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-contactor-manufacturer-comparison-matrix\">\u0645\u0635\u0641\u0648\u0641\u0629 \u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u064a\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u0641\u0631\u063a\u0629 \u0645\u0646 \u0627\u0644\u0647\u0648\u0627\u0621<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0646\u0648\u0639 \u0627\u0644\u0645\u0648\u0631\u062f<\/th><th>\u0642\u0648\u0629 \u0627\u0644\u0645\u0646\u062a\u062c<\/th><th>\u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0623\u0646\u0633\u0628<\/th><th>\u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0645\u0634\u062a\u0631\u064a \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0645\u0634\u062a\u0631\u064a<\/th><\/tr><\/thead><tbody><tr><td>\u0639\u0644\u0627\u0645\u0629 \u062a\u062c\u0627\u0631\u064a\u0629 \u0639\u0627\u0644\u0645\u064a\u0629 \u0645\u062a\u0645\u064a\u0632\u0629<\/td><td>\u0642\u0627\u0639\u062f\u0629 \u062a\u062b\u0628\u064a\u062a \u0648\u0627\u0633\u0639\u0629\u060c \u0648\u0648\u062b\u0627\u0626\u0642 \u0646\u0627\u0636\u062c\u0629\u060c \u0648\u0634\u0628\u0643\u0629 \u062e\u062f\u0645\u0629 \u0642\u0648\u064a\u0629.<\/td><td>\u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629 \u0648\u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0648\u0627\u0644\u0645\u0634\u0631\u0648\u0639\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u062a\u063a\u0637\u064a\u0629 \u062e\u062f\u0645\u0629 \u0639\u0627\u0644\u0645\u064a\u0629.<\/td><td>\u0633\u0639\u0631 \u0623\u0639\u0644\u0649\u060c \u0648\u0645\u0647\u0644\u0629 \u0632\u0645\u0646\u064a\u0629 \u0623\u0637\u0648\u0644\u060c \u0648\u0645\u0631\u0648\u0646\u0629 \u0623\u0642\u0644 \u0644\u0644\u062a\u0643\u0627\u0645\u0644 \u063a\u064a\u0631 \u0627\u0644\u0642\u064a\u0627\u0633\u064a.<\/td><\/tr><tr><td>\u0634\u0631\u0643\u0629 MV \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0629 \u0641\u064a \u0627\u0644\u0645\u0631\u0643\u0628\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u0628\u0627\u0634\u0631 \u0645\u0646 \u0627\u0644\u0645\u0635\u0646\u0639 \u0645\u062b\u0644 XBRELE<\/td><td>\u0627\u0644\u062a\u062e\u0635\u064a\u0635\u060c \u0648\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u060c \u0648\u062f\u0639\u0645 \u062a\u0643\u0627\u0645\u0644 \u0627\u0644\u0644\u0648\u062d\u0629\u060c \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u0647\u0644\u0629 \u0627\u0644\u0632\u0645\u0646\u064a\u0629.<\/td><td>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629\u060c \u0648\u0627\u0644\u062a\u0639\u062f\u064a\u0646\u060c \u0648\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0643\u062b\u0641\u0627\u062a\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a.<\/td><td>\u062a\u062d\u0642\u0642 \u0645\u0646 \u062a\u0642\u0627\u0631\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0648\u0645\u0637\u0627\u0628\u0642\u0629 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u060c \u0648\u0641\u0626\u0629 \u0627\u0644\u0639\u0645\u0644\u060c \u0648\u062e\u0637\u0629 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0642\u0628\u0644 \u0627\u0644\u0637\u0644\u0628.<\/td><\/tr><tr><td>\u0645\u0648\u0631\u062f \u0633\u0644\u0639 \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u062a\u0643\u0644\u0641\u0629<\/td><td>\u0633\u0639\u0631 \u0627\u0644\u0648\u062d\u062f\u0629 \u0627\u0644\u062a\u0646\u0627\u0641\u0633\u064a \u0644\u0644\u0637\u0644\u0628 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644\u064a \u0627\u0644\u0628\u0633\u064a\u0637.<\/td><td>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u062d\u0631\u062c\u0629 \u0630\u0627\u062a \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0648\u0627\u0636\u062d\u0629 \u0648\u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u0644\u064a\u0629.<\/td><td>\u0639\u0645\u0642 \u0627\u0644\u062a\u0648\u062b\u064a\u0642\u060c \u0648\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u062a\u062d\u0645\u0644\u060c \u0648\u0645\u0648\u0627\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u060c \u0648\u062f\u0639\u0645 \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u0628\u064a\u0639.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"when-to-choose-xbrele-for-vacuum-contactor-projects\">\u0645\u062a\u0649 \u062a\u062e\u062a\u0627\u0631 XBRELE \u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629<\/h2>\n\n\n\n<p>\u0627\u062e\u062a\u0631 XBRELE \u0639\u0646\u062f\u0645\u0627 \u064a\u062c\u0628 \u0645\u0637\u0627\u0628\u0642\u0629 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0645\u0639 \u0627\u0644\u062e\u062f\u0645\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629: \u0628\u062f\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0623\u0648 \u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u060c \u0623\u0648 \u062a\u0628\u062f\u064a\u0644 \u0628\u0646\u0643 \u0627\u0644\u0645\u0643\u062b\u0641\u0627\u062a\u060c \u0623\u0648 \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u060c \u0623\u0648 \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0627\u0644\u0639\u0627\u0644\u064a\u0629\u060c \u0623\u0648 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a. \u0648\u0627\u0644\u0647\u062f\u0641 \u0644\u064a\u0633 \u0641\u0642\u0637 \u0633\u0639\u0631 \u0634\u0631\u0627\u0621 \u0623\u0642\u0644\u060c \u0648\u0644\u0643\u0646 \u0645\u0637\u0627\u0628\u0642\u0629 \u0635\u062d\u064a\u062d\u0629 \u0644\u0644\u062e\u062f\u0645\u0629 \u0645\u0639 \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0627\u0644\u0639\u0645\u0644\u064a.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-contactor-rfq-checklist\">\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0637\u0644\u0628 \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0641\u0631\u0627\u063a<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 \u0648\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646 \u0648\u0641\u0626\u0629 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0648\u062a\u0631\u062f\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062a\u0648\u0642\u0639\u0629 \u0641\u064a \u0627\u0644\u0633\u0627\u0639\u0629.<\/li><li>\u0646\u0648\u0639 \u0627\u0644\u062d\u0650\u0645\u0644: \u0645\u062d\u0631\u0643\u060c \u0623\u0648 \u0645\u062d\u0648\u0644\u060c \u0623\u0648 \u0628\u0646\u0643 \u0645\u0643\u062b\u0641\u0627\u062a\u060c \u0623\u0648 \u0645\u0641\u0627\u0639\u0644\u060c \u0623\u0648 \u0645\u063a\u0630\u064a \u062a\u0639\u062f\u064a\u0646\u060c \u0623\u0648 \u0645\u063a\u0630\u064a \u0635\u0646\u0627\u0639\u064a \u0639\u0627\u0645.<\/li><li>\u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u060c \u0648\u0646\u0648\u0639 \u0627\u0644\u0645\u0632\u0644\u0627\u062c\u060c \u0648\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a\u060c \u0648\u0645\u0646\u0637\u0642 \u062a\u0639\u0634\u064a\u0642 \u0627\u0644\u0644\u0648\u062d\u0629.<\/li><li>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u0648\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u062a\u0635\u0646\u064a\u0641 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0641\u062d\u0635 \u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633.<\/li><li>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629\u060c \u0648\u062a\u0642\u0627\u0631\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0648\u0627\u0644\u0631\u0633\u0648\u0645\u0627\u062a\u060c \u0648\u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631\u060c \u0648\u0646\u0637\u0627\u0642 \u0627\u0644\u0633\u0639\u0631 \u0627\u0644\u0645\u0633\u062a\u0647\u062f\u0641\u060c \u0648\u0627\u0644\u0645\u0647\u0644\u0629 \u0627\u0644\u0632\u0645\u0646\u064a\u0629.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-manufacturer-selection-determines-total-cost-of-ownership\">\u0644\u0645\u0627\u0630\u0627 \u064a\u062d\u062f\u062f \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629<\/h2>\n\n\n\n<p>\u064a\u0639\u062a\u0645\u062f \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0639\u0644\u0649 \u0622\u0644\u064a\u062a\u064a \u062a\u0622\u0643\u0644 \u0645\u0633\u062a\u0642\u0644\u062a\u064a\u0646: \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 (\u062f\u0648\u0631\u0627\u062a \u0627\u0644\u0641\u062a\u062d\/\u0627\u0644\u0625\u063a\u0644\u0627\u0642) \u0648\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 (\u0635\u0646\u0639\/\u0643\u0633\u0631 \u0627\u0644\u062a\u064a\u0627\u0631 \u062a\u062d\u062a \u0627\u0644\u062d\u0645\u0644). \u062a\u0641\u0634\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0631\u062e\u064a\u0635\u0629 \u0641\u064a \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a - \u062a\u062a\u0639\u0628 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u0627\u062a\u060c \u0648\u062a\u062a\u0622\u0643\u0644 \u0627\u0644\u0648\u0635\u0644\u0627\u062a\u060c \u0648\u062a\u062a\u0639\u0637\u0644 \u0627\u0644\u0622\u0644\u064a\u0629 \u0628\u0639\u062f 50,000 \u0639\u0645\u0644\u064a\u0629 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0645\u0644\u064a\u0648\u0646 \u0639\u0645\u0644\u064a\u0629. \u0623\u0645\u0627 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0645\u062a\u0627\u0632\u0629 \u0641\u062a\u0641\u0634\u0644 \u0639\u0644\u0649 \u0623\u0633\u0627\u0633 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a - \u062a\u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0628\u0634\u0643\u0644 \u0645\u062a\u0648\u0642\u0639\u060c \u0648\u062a\u0635\u0644 \u0625\u0644\u0649 \u0646\u0647\u0627\u064a\u0629 \u0639\u0645\u0631\u0647\u0627 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0628\u0639\u062f \u062f\u0648\u0631\u0627\u062a \u062a\u062d\u0645\u064a\u0644 \u0645\u0648\u062b\u0642\u0629 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0639\u0634\u0648\u0627\u0626\u064a\u0629. \u0644\u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u060c \u0642\u0645 \u0628\u0645\u0648\u0627\u0621\u0645\u0629 \u0647\u0630\u0627 \u0627\u0644\u062a\u0645\u064a\u064a\u0632 \u0645\u0639 <a href=\"https:\/\/xbrele.com\/ar\/mechanical-life-vs-electrical-life-contactor-endurance\/\">\u0625\u0637\u0627\u0631 \u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0642\u0627\u0628\u0644 \u0625\u0637\u0627\u0631 \u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/a>.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/strong>&nbsp;\u064a\u062d\u0643\u0645 \u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0628\u062f\u064a\u0644:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0628\u0627\u062f\u0626\u0627\u062a \u062a\u0634\u063a\u064a\u0644 \u0645\u0636\u062e\u0629 \u0627\u0644\u0637\u0631\u062f \u0627\u0644\u0645\u0631\u0643\u0632\u064a: 200-500 \u0639\u0645\u0644\u064a\u0629\/\u064a\u0648\u0645\u064a\u064b\u0627<\/li>\n\n\n\n<li>\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u062a\u0643\u064a\u064a\u0641 \u0627\u0644\u0647\u0648\u0627\u0621 \u0648\u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0648\u0627\u0644\u062a\u0643\u064a\u064a\u0641 10-50 \u0639\u0645\u0644\u064a\u0629\/\u064a\u0648\u0645\u064a\u064b\u0627<\/li>\n\n\n\n<li>\u0646\u0627\u0642\u0644\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646: 100-300 \u0639\u0645\u0644\u064a\u0629\/\u064a\u0648\u0645\u064a\u064b\u0627<\/li>\n<\/ul>\n\n\n\n<p>\u0645\u0648\u0635\u0650\u0651\u0644 \u0645\u0635\u0646\u0651\u0641\u00a0<strong>1 \u0645\u0644\u064a\u0648\u0646 \u0639\u0645\u0644\u064a\u0629 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>\u00a0\u0641\u064a \u062a\u0637\u0628\u064a\u0642 200 \u0639\u0645\u0644\u064a\u0629\/\u064a\u0648\u0645\u064a\u064b\u0627 \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0641\u062d\u0635 \u0643\u0644\u00a0<strong>13.7 \u0633\u0646\u0629<\/strong>\u00a0(1,000,000 \/ 200 \/ 365). \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0645\u0642\u062f\u0631 \u0628 500,000 \u0639\u0645\u0644\u064a\u0629 \u0641\u062d\u0635 \u0643\u0644\u00a0<strong>6.8 \u0633\u0646\u0648\u0627\u062a<\/strong>-\u0645\u0636\u0627\u0639\u0641\u0629 \u0639\u0628\u0621 \u0635\u064a\u0627\u0646\u0629 \u062f\u0648\u0631\u0629 \u0627\u0644\u062d\u064a\u0627\u0629.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>&nbsp;\u064a\u062d\u0643\u0645 \u062a\u0648\u0642\u064a\u062a \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633. \u062a\u062d\u062f\u062f \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 62271-106 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0639\u0646\u062f \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646 \u0644\u0641\u0626\u0629 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 AC-4 (\u0628\u062f\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u062a\u062f\u0641\u0642 \u0627\u0644\u0639\u0627\u0644\u064a)\u060c \u0628\u064a\u0646\u0645\u0627 \u064a\u062a\u0645\u0627\u0634\u0649 \u062a\u0641\u0633\u064a\u0631 \u0641\u0626\u0629 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0639 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/74487\" target=\"_blank\" rel=\"noopener\">IEC 60947-4-1<\/a>. \u0623\u0638\u0647\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0630\u064a \u0623\u064f\u062c\u0631\u064a \u0639\u0644\u0649 150 \u0645\u0646\u0634\u0623\u0629 \u0623\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 \u062a\u0642\u062f\u0645 \u0628\u0627\u0633\u062a\u0645\u0631\u0627\u0631 \u0645\u0627 \u0628\u064a\u0646 8000 \u0625\u0644\u0649 12000 \u0639\u0645\u0644\u064a\u0629 AC-4 \u0642\u0628\u0644 \u0623\u0646 \u064a\u062a\u062c\u0627\u0648\u0632 \u0627\u0644\u062a\u0622\u0643\u0644 \u062d\u062f\u0648\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0641\u0634\u0644 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u062f\u0646\u0649 \u0639\u0646\u062f 3000 \u0625\u0644\u0649 5000 \u0639\u0645\u0644\u064a\u0629.<\/p>\n\n\n\n<p>\u0627\u0644\u0641\u0647\u0645&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/\">\u0623\u0633\u0627\u0633\u064a\u0627\u062a \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/a>&nbsp;\u0648&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\">\u0643\u064a\u0641 \u062a\u0639\u0645\u0644 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0639\u0644\u0649 \u0625\u0637\u0641\u0627\u0621 \u0627\u0644\u0623\u0642\u0648\u0627\u0633<\/a>&nbsp;\u0633\u064a\u0627\u0642\u064b\u0627 \u0623\u0633\u0627\u0633\u064a\u064b\u0627 \u0644\u062a\u0642\u064a\u064a\u0645 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01.webp\" alt=\"\u0647\u0631\u0645 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0644\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u064a\u064f\u0638\u0647\u0631 \u0642\u0637\u0627\u0639\u0627\u062a \u0645\u0648\u0631\u062f\u064a \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0627\u0644\u0645\u062a\u0645\u064a\u0632\u0629 \u0648\u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0627\u0644\u0639\u0627\u0645\u0629\" class=\"wp-image-2387\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">FIG-01: \u062a\u0639\u0643\u0633 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0639\u0631\u0648\u0636 \u0642\u064a\u0645\u0629 \u0645\u062a\u0645\u064a\u0632\u0629 - \u064a\u0648\u0641\u0631 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 1 \u0623\u0642\u0635\u0649 \u0642\u062f\u0631 \u0645\u0646 \u0627\u0644\u062a\u062d\u0645\u0644 \u0648\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0639\u0627\u0644\u0645\u064a \u0628\u0623\u0633\u0639\u0627\u0631 \u0645\u0645\u062a\u0627\u0632\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u064a\u0642\u062f\u0645 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 3 \u0623\u0642\u0644 \u062a\u0643\u0644\u0641\u0629 \u0645\u0639 \u0639\u0628\u0621 \u0635\u064a\u0627\u0646\u0629 \u0623\u0639\u0644\u0649.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-1-global-premium-manufacturers\">\u0627\u0644\u0645\u0633\u062a\u0648\u0649 1: \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0627\u0644\u0645\u062a\u0645\u064a\u0632\u0629<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-abb-switzerlandsweden\">1. ABB (\u0633\u0648\u064a\u0633\u0631\u0627\/\u0627\u0644\u0633\u0648\u064a\u062f)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: VM1\u060c VD4H\u060c VD4H (\u0647\u062c\u064a\u0646 VCB\/\u0645\u062a\u0635\u0644)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>: 3.6 - 40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: \u0645\u0627 \u064a\u0635\u0644 \u0625\u0644\u0649 1,000,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644 \u062d\u062a\u0649 1,000,000 (\u0645\u0639\u062a\u0645\u062f\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 62271-106)<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>: 10,000 \u0639\u0645\u0644\u064a\u0629 \u0639\u0646\u062f \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/p>\n\n\n\n<p>\u062a\u0633\u062a\u0647\u062f\u0641 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0645\u0646 ABB \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u062d\u0631\u062c\u0629 \u062d\u064a\u062b \u062a\u062a\u062c\u0627\u0648\u0632 \u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0644\u062a\u0639\u0637\u0644 \u0623\u0642\u0633\u0627\u0637 \u0627\u0644\u0645\u0639\u062f\u0627\u062a. \u062a\u0648\u0641\u0631 \u0633\u0644\u0633\u0644\u0629 VM1 \u062a\u0648\u0642\u064a\u062a\u064b\u0627 \u0645\u0636\u0628\u0648\u0637\u064b\u0627 \u0645\u0633\u0628\u0642\u064b\u0627 \u0641\u064a \u0627\u0644\u0645\u0635\u0646\u0639\u060c \u0648\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0625\u0636\u0627\u0641\u064a\u0629 \u0645\u0639 \u0648\u0627\u062c\u0647\u0627\u062a \u0645\u0637\u0644\u064a\u0629 \u0628\u0627\u0644\u0630\u0647\u0628\u060c \u0648\u062a\u0634\u062e\u064a\u0635\u0627\u062a \u0634\u0627\u0645\u0644\u0629. \u062a\u062a\u0636\u0645\u0646 \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u0641\u0646\u064a\u0629 \u062a\u0642\u0627\u0631\u064a\u0631 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0645\u0646 KEMA (\u0647\u0648\u0644\u0646\u062f\u0627) \u0648 CPRI (\u0627\u0644\u0647\u0646\u062f).<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0623\u0637\u0648\u0644 \u0641\u062a\u0631\u0629 \u062a\u062d\u0645\u0651\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0641\u064a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629 (\u0642\u0645\u0646\u0627 \u0628\u0642\u064a\u0627\u0633 1.2 \u0645\u0644\u064a\u0648\u0646 \u0639\u0645\u0644\u064a\u0629 \u0642\u0628\u0644 \u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0641\u064a \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0636\u062e\u0629 \u0627\u0644\u0628\u062d\u0631\u064a\u0629)<\/li>\n\n\n\n<li>\u0634\u0628\u0643\u0629 \u062e\u062f\u0645\u0629 \u0639\u0627\u0644\u0645\u064a\u0629 \u0645\u0639 \u062a\u0648\u0635\u064a\u0644 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u062e\u0644\u0627\u0644 \u0623\u0642\u0644 \u0645\u0646 48 \u0633\u0627\u0639\u0629 \u0641\u064a \u0623\u0643\u062b\u0631 \u0645\u0646 80 \u062f\u0648\u0644\u0629<\/li>\n\n\n\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0634\u0647\u0627\u062f\u0627\u062a IEC\/IEEE \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0627\u0644\u062a\u0623\u0647\u064a\u0644 \u0627\u0644\u0632\u0644\u0632\u0627\u0644\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0639\u0644\u0627\u0648\u0629 \u0627\u0644\u0633\u0639\u0631 25-40% \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0635\u064a\u0646\u064a\u0629<\/li>\n\n\n\n<li>\u0645\u0647\u0644\u0629 \u062a\u062a\u0631\u0627\u0648\u062d \u0628\u064a\u0646 12 \u064816 \u0623\u0633\u0628\u0648\u0639\u064b\u0627 \u0644\u0644\u0645\u0644\u0641\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629<\/li>\n\n\n\n<li>\u0645\u0628\u0627\u0644\u063a\u0629 \u0641\u064a \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u062a\u0643\u064a\u064a\u0641 \u0627\u0644\u0647\u0648\u0627\u0621 \u063a\u064a\u0631 \u0627\u0644\u062d\u0631\u062c\u0629 \u0623\u0648 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0627\u062a \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u0645\u0647\u0627\u0645<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0627\u0644\u0646\u0648\u0648\u064a\u0629\u060c \u0627\u0644\u062f\u0641\u0639 \u0627\u0644\u0628\u062d\u0631\u064a\u060c \u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0646\u0641\u0637 \u0648\u0627\u0644\u063a\u0627\u0632 \u0627\u0644\u062d\u0631\u062c\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-schneider-electric-france\">2. \u0634\u0646\u0627\u064a\u062f\u0631 \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0641\u0631\u0646\u0633\u0627)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: Recloser-M\u060c SM6 (\u0648\u062d\u062f\u0629 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0645\u062f\u0645\u062c\u0629)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>:: 7.2 - 24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 500,000 - 1,000,000,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>:: 8,000 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u062a\u0643\u0627\u0645\u0644 \u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a\u0629 \u0634\u0646\u0627\u064a\u062f\u0631 \u0644\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0639 \u0646\u0638\u0627\u0645 EcoStruxure \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629 \u0639\u0628\u0631 \u0645\u0633\u062a\u0634\u0639\u0631\u0627\u062a \u0625\u0646\u062a\u0631\u0646\u062a \u0627\u0644\u0623\u0634\u064a\u0627\u0621 \u0648\u0627\u0644\u062a\u062d\u0644\u064a\u0644\u0627\u062a \u0627\u0644\u0633\u062d\u0627\u0628\u064a\u0629. \u062a\u062f\u0645\u062c \u0627\u0644\u0648\u062d\u062f\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0627\u0644\u062d\u0644\u0642\u064a\u0629 SM6 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0639 \u0645\u0641\u0627\u062a\u064a\u062d \u0643\u0633\u0631 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0645\u062f\u0645\u062c\u0629\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u0625\u0646\u0634\u0627\u0621 \u0639\u0642\u062f \u062a\u0648\u0632\u064a\u0639 \u062b\u0627\u0646\u0648\u064a\u0629 \u0645\u062f\u0645\u062c\u0629 \u0634\u0627\u0626\u0639\u0629 \u0641\u064a \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0643\u0627\u0645\u0644 \u0642\u0648\u064a \u0628\u064a\u0646 SCADA\/\u0627\u0644\u0623\u062a\u0645\u062a\u0629 (\u0645\u0648\u062f\u0628\u0648\u0633\u060c IEC 61850)<\/li>\n\n\n\n<li>\u0628\u0631\u0627\u0645\u062c \u062a\u062f\u0631\u064a\u0628\u064a\u0629 \u0634\u0627\u0645\u0644\u0629 \u0644\u0628\u0646\u0627\u0629 \u0627\u0644\u0644\u0648\u062d\u0627\u062a<\/li>\n\n\n\n<li>\u062a\u0642\u0644\u0644 \u0627\u0644\u062d\u0644\u0648\u0644 \u0627\u0644\u0645\u0635\u0645\u0645\u0629 \u0645\u0633\u0628\u0642\u064b\u0627 \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0635\u0645\u064a\u0645<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0648\u0627\u0641\u0631 \u0645\u062d\u062f\u0648\u062f \u0644\u0645\u0644\u0627\u0645\u0633 \u0645\u0633\u062a\u0642\u0644 (\u0645\u062c\u0645\u0639\u0629 \u0645\u0639 \u0648\u062d\u062f\u0627\u062a \u0625\u062f\u0627\u0631\u0629 \u0639\u0644\u0627\u0642\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u0627\u0621)<\/li>\n\n\n\n<li>\u062a\u0643\u0644\u0641\u0629 \u0623\u0639\u0644\u0649 \u0645\u0646 \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0646\u0642\u064a\u0629<\/li>\n\n\n\n<li>\u0634\u0628\u0643\u0629 \u0627\u0644\u062e\u062f\u0645\u0627\u062a \u0627\u0644\u0645\u062a\u0645\u0631\u0643\u0632\u0629 \u0641\u064a \u0623\u0648\u0631\u0648\u0628\u0627 (\u0623\u0636\u0639\u0641 \u0641\u064a \u0622\u0633\u064a\u0627 \u0648\u0627\u0644\u0645\u062d\u064a\u0637 \u0627\u0644\u0647\u0627\u062f\u0626)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0634\u0628\u0643\u0629 \u0627\u0644\u0630\u0643\u064a\u0629\u060c \u0648\u062a\u0643\u0627\u0645\u0644 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062a\u062c\u062f\u062f\u0629\u060c \u0648\u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u062b\u0627\u0646\u0648\u064a \u0644\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0639\u0627\u0645\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-eaton-usaireland\">3. \u0625\u064a\u062a\u0648\u0646 (\u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629\/\u0625\u064a\u0631\u0644\u0646\u062f\u0627)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: VCP-W\u060c \u0645\u0627\u063a\u0646\u0648\u0645 DS (\u062c\u0647\u062f \u0645\u062a\u0648\u0633\u0637)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>: 4.16 - 15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>:: 600,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>:: 6,000-8,000 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u0648\u062a\u0633\u062a\u0647\u062f\u0641 \u0634\u0631\u0643\u0629 \u0625\u064a\u062a\u0648\u0646 \u0627\u0644\u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0641\u064a \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629 \u0628\u0634\u0647\u0627\u062f\u0627\u062a UL\/CSA \u0648\u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u062d\u062a\u0648\u0627\u0621 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u064a\u062a\u0646\u0627\u0633\u0628 \u0645\u0648\u0635\u0644 VCP-W \u0645\u0639 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 2B \u0648\u0641\u0642\u0627\u064b \u0644\u0645\u0639\u064a\u0627\u0631 IEEE C37.20.7\u060c \u0648\u0647\u0648 \u0645\u0637\u0644\u0628 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0646\u0641\u0637 \u0648\u0627\u0644\u063a\u0627\u0632.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0623\u0641\u0636\u0644 \u0645\u064a\u0632\u0627\u062a \u062a\u062e\u0641\u064a\u0641 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (\u0625\u0639\u0627\u062f\u0629 \u062a\u0648\u062c\u064a\u0647 \u0627\u0644\u062a\u0646\u0641\u064a\u0633 \u0648\u062a\u062e\u0641\u064a\u0641 \u0627\u0644\u0636\u063a\u0637)<\/li>\n\n\n\n<li>\u062a\u0648\u0632\u064a\u0639 \u0642\u0648\u064a \u0641\u064a \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629 (\u0623\u0643\u062b\u0631 \u0645\u0646 30 \u0645\u0631\u0643\u0632 \u062e\u062f\u0645\u0629)<\/li>\n\n\n\n<li>\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0645\u0639 \u0642\u0648\u0627\u0637\u0639 \u0643\u0627\u062a\u0644\u0631-\u0647\u0627\u0645\u0631 \u0627\u0644\u0642\u062f\u064a\u0645\u0629 (\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0648\u0627\u062c\u062f \u0645\u062d\u062f\u0648\u062f \u062e\u0627\u0631\u062c \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629<\/li>\n\n\n\n<li>\u0641\u0626\u0627\u062a \u062c\u0647\u062f \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629 (\u062a\u0631\u0643\u0632 \u0639\u0644\u0649 4.16 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 13.8 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)<\/li>\n\n\n\n<li>\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0641\u064a \u0627\u0644\u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u0622\u0633\u064a\u0648\u064a\u0629 \u0628\u0633\u0628\u0628 \u0631\u0633\u0648\u0645 \u0627\u0644\u0627\u0633\u062a\u064a\u0631\u0627\u062f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629\u060c \u0648\u0627\u0644\u062a\u0639\u062f\u064a\u0646 (\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644 MSHA)\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u062a\u0639\u062f\u064a\u0644 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-2-industrial-oem-specialists\">\u0627\u0644\u0645\u0633\u062a\u0648\u0649 2: \u0623\u062e\u0635\u0627\u0626\u064a\u0648 \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-xbrele-china\">4. XBRELE (\u0627\u0644\u0635\u064a\u0646)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: CKG3, CKG4 (\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062d\u0645\u0644)\u060c JCZ (\u0645\u0639\u062a\u0645\u062f\u0629 \u0645\u0646 \u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0641\u062d\u0645)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>: 3.6-12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 1,000,000 \u0639\u0645\u0644\u064a\u0629 (\u0627\u0644\u0641\u0626\u0629 M2 \u062d\u0633\u0628 IEC 62271-106)<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>:: 8,000 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u0639\u0645\u0644 XBRELE \u0643\u0640&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/vacuum-contactor-vs-vacuum-circuit-breaker-medium-voltage-panel\/\">\u0645\u064f\u0635\u0646\u0650\u0651\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0644\u0645\u0648\u0635\u0650\u0651\u0644 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0626\u064a<\/a>&nbsp;\u0645\u0639 \u0623\u0643\u062b\u0631 \u0645\u0646 15 \u0639\u0627\u0645\u064b\u0627 \u0645\u0646 \u0627\u0644\u062a\u062e\u0635\u0635 \u0641\u064a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0627\u0644\u0635\u0646\u0627\u0639\u0627\u062a \u0627\u0644\u062b\u0642\u064a\u0644\u0629. \u0648\u062a\u0642\u0644\u0644 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u0645\u0628\u0627\u0634\u0631\u0629 \u0645\u0646 \u0627\u0644\u0645\u0635\u0646\u0639 \u0645\u0646 \u0647\u0648\u0627\u0645\u0634 \u0627\u0644\u0631\u0628\u062d \u0644\u0644\u0645\u0648\u0632\u0639\u064a\u0646 \u0645\u0639 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0634\u0647\u0627\u062f\u0629 IEC \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u062e\u062a\u0628\u0631\u0627\u062a CESI (\u0625\u064a\u0637\u0627\u0644\u064a\u0627) \u0648 KEMA.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u064a\u0632\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 30-50% \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0645\u0646 \u0627\u0644\u0641\u0626\u0629 1 \u0630\u0627\u062a \u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0643\u0627\u0641\u0626\u0629<\/li>\n\n\n\n<li>\u0634\u0647\u0627\u062f\u0629 \u0645\u0639\u062a\u0645\u062f\u0629 \u0644\u0644\u0623\u062c\u0648\u0627\u0621 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0627\u0646\u0641\u062c\u0627\u0631 (Ex d IIB\u060c \u0634\u0647\u0627\u062f\u0629 MA \u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0641\u062d\u0645)<\/li>\n\n\n\n<li>\u0633\u0631\u0639\u0629 \u0627\u0644\u062a\u062e\u0635\u064a\u0635 (\u0633\u0631\u0639\u0629 \u0627\u0644\u062a\u062e\u0635\u064a\u0635 (7 \u0623\u064a\u0627\u0645 \u0644\u0644\u0645\u0644\u0641\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629)<\/li>\n\n\n\n<li>\u062f\u0639\u0645 \u0641\u0646\u064a \u0645\u0628\u0627\u0634\u0631 \u0645\u0646 \u0627\u0644\u0641\u0631\u064a\u0642 \u0627\u0644\u0647\u0646\u062f\u0633\u064a (\u0644\u0627 \u064a\u0648\u062c\u062f \u0648\u0633\u0637\u0627\u0621 \u0645\u0648\u0632\u0639)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0634\u0628\u0643\u0629 \u0627\u0644\u062e\u062f\u0645\u0627\u062a \u062a\u0642\u062a\u0635\u0631 \u0639\u0644\u0649 \u0645\u0646\u0637\u0642\u0629 \u0622\u0633\u064a\u0627 \u0648\u0627\u0644\u0645\u062d\u064a\u0637 \u0627\u0644\u0647\u0627\u062f\u0626 + \u0634\u0631\u0643\u0627\u0621 \u0623\u0648\u0631\u0648\u0628\u064a\u064a\u0646 \u0645\u062e\u062a\u0627\u0631\u064a\u0646<\/li>\n\n\n\n<li>\u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0628\u0627\u0644\u0644\u063a\u0629 \u0627\u0644\u0625\u0646\u062c\u0644\u064a\u0632\u064a\u0629 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0635\u062d\u0629 \u0627\u0644\u062a\u0631\u062c\u0645\u0629<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0639\u0631\u0641 \u0639\u0644\u0649 \u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 \u0627\u0644\u0639\u0627\u0644\u0645\u064a \u0641\u064a \u0627\u0644\u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u063a\u0631\u0628\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u060c \u0648\u0635\u0627\u0646\u0639\u064a \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629\u060c \u0648\u062e\u0637\u0648\u0637 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0630\u0627\u062a \u0627\u0644\u062d\u062c\u0645 \u0627\u0644\u0643\u0628\u064a\u0631\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a \u0627\u0644\u062d\u0633\u0627\u0633\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u062a\u0643\u0644\u0641\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-ls-electric-south-korea\">5. LS Electric (\u0643\u0648\u0631\u064a\u0627 \u0627\u0644\u062c\u0646\u0648\u0628\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: VCF-12\u060c VCC (\u062a\u0635\u0645\u064a\u0645 \u0645\u062f\u0645\u062c)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>:: 7.2 - 24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 500,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>:: 000 6 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u0631\u0643\u0632 \u0634\u0631\u0643\u0629 LS Electric (\u0627\u0644\u0645\u0639\u0631\u0648\u0641\u0629 \u0633\u0627\u0628\u0642\u064b\u0627 \u0628\u0627\u0633\u0645 LG Industrial Systems) \u0639\u0644\u0649 \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u0644\u0628\u0635\u0645\u0629 \u0627\u0644\u0645\u062f\u0645\u062c\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u062d\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629. \u064a\u062d\u0642\u0642 \u0642\u0648\u0627\u0637\u0639 VCF-12 \u0639\u0631\u0636\u064b\u0627 \u0623\u0635\u063a\u0631 \u0628\u0645\u0642\u062f\u0627\u0631 30% \u0645\u0646 \u0645\u062b\u064a\u0644\u0627\u062a\u0647\u0627 \u0645\u0646 ABB VM1\u060c \u0648\u0647\u0648 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u062a\u0639\u062f\u064a\u0644 \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0641\u0627\u062a\u064a\u062d \u0646\u0638\u0645 \u0627\u0644\u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0627\u0644\u062c\u063a\u0631\u0627\u0641\u064a\u0629 \u0627\u0644\u0642\u062f\u064a\u0645\u0629.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0635\u0645\u064a\u0645 \u0645\u062f\u0645\u062c \u0631\u0627\u0626\u062f \u0641\u064a \u0627\u0644\u0635\u0646\u0627\u0639\u0629 (\u0639\u0631\u0636 165 \u0645\u0645 \u0644\u062c\u0647\u062f 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 400 \u0623\u0645\u0628\u064a\u0631)<\/li>\n\n\n\n<li>\u062d\u0636\u0648\u0631 \u0642\u0648\u064a \u0641\u064a \u0643\u0648\u0631\u064a\u0627 \u0627\u0644\u062c\u0646\u0648\u0628\u064a\u0629 \u0648\u062c\u0646\u0648\u0628 \u0634\u0631\u0642 \u0622\u0633\u064a\u0627 \u0641\u064a \u0628\u0646\u0627\u0621 \u0627\u0644\u0633\u0641\u0646<\/li>\n\n\n\n<li>\u0623\u0633\u0639\u0627\u0631 \u062a\u0646\u0627\u0641\u0633\u064a\u0629 (20% \u0623\u0642\u0644 \u0645\u0646 ABB\u060c 15% \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u0633\u0639\u0631 \u0627\u0644\u0635\u064a\u0646\u064a \u0627\u0644\u0639\u0627\u0645)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0642\u062f\u0631\u0629 \u062a\u062d\u0645\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 1 (500 \u0623\u0644\u0641 \u0645\u0642\u0627\u0628\u0644 \u0645\u0644\u064a\u0648\u0646 \u0639\u0645\u0644\u064a\u0629)<\/li>\n\n\n\n<li>\u0636\u0639\u0641 \u062a\u0648\u0627\u0641\u0631 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u062e\u0627\u0631\u062c \u0622\u0633\u064a\u0627<\/li>\n\n\n\n<li>\u0645\u0637\u0628\u0648\u0639\u0627\u062a \u0641\u0646\u064a\u0629 \u0645\u062d\u062f\u0648\u062f\u0629 \u0628\u0627\u0644\u0644\u063a\u0629 \u0627\u0644\u0625\u0646\u062c\u0644\u064a\u0632\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0628\u062d\u0631\u064a\u0629\u060c \u0648\u0623\u062d\u0648\u0627\u0636 \u0628\u0646\u0627\u0621 \u0627\u0644\u0633\u0641\u0646 \u0627\u0644\u0643\u0648\u0631\u064a\u0629\u060c \u0648\u0627\u0644\u062a\u0639\u062f\u064a\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a\u0629 \u0627\u0644\u0645\u062f\u0645\u062c\u0629\u060c \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u062f\u0645\u062c \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6.-siemens-germany\">6. Siemens (\u0623\u0644\u0645\u0627\u0646\u064a\u0627)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: 3AH (\u0642\u062f\u064a\u0645)\u060c SIMOVAC (\u0647\u062c\u064a\u0646 VCB-\u0645\u062a\u0635\u0644 VCB)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>:: 7.2-40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 500,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>:: 000 7 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062d\u0648\u0651\u0644\u062a \u0633\u064a\u0645\u0646\u0632 \u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0646\u062d\u0648 \u0642\u0648\u0627\u0637\u0639 SIMOVAC \u0627\u0644\u0647\u062c\u064a\u0646\u0629 \u0627\u0644\u062a\u064a \u062a\u062c\u0645\u0639 \u0628\u064a\u0646 \u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629 (\u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0623\u0639\u0637\u0627\u0644) \u0645\u0639 \u0645\u0647\u0645\u0629 \u0627\u0644\u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631. \u0644\u0627 \u062a\u0632\u0627\u0644 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0646\u0642\u064a\u0629 (\u0633\u0644\u0633\u0644\u0629 3AH) \u0645\u062a\u0648\u0641\u0631\u0629 \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u0648\u0627\u062c\u0647 \u0627\u0644\u062a\u062e\u0644\u0635 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a \u0644\u0635\u0627\u0644\u062d \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u062a\u0643\u0627\u0645\u0644 \u0645\u0639 \u0645\u0631\u062d\u0644\u0627\u062a SIPROTEC \u0645\u0646 \u0633\u064a\u0645\u0646\u0633 \u0648\u0623\u062a\u0645\u062a\u0629 \u0628\u0648\u0627\u0628\u0629 TIA<\/li>\n\n\n\n<li>\u062f\u0639\u0645 \u0647\u0646\u062f\u0633\u064a \u0642\u0648\u064a \u0644\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0647\u0646\u062f\u0633\u064a\u0629 \u0644\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629<\/li>\n\n\n\n<li>\u0645\u0631\u0627\u0642\u0628\u0629 \u062c\u0648\u062f\u0629 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0623\u0644\u0645\u0627\u0646\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u062e\u0637 \u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0645\u0642\u0627\u0648\u0644\u064a\u0646 (\u062a\u0639\u0637\u064a \u0634\u0631\u0643\u0629 Siemens \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0645\u0631\u0643\u0628\u0627\u062a VCBs)<\/li>\n\n\n\n<li>\u0628\u0627\u0647\u0638\u0629 \u0627\u0644\u062b\u0645\u0646 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0645\u0633\u062a\u0642\u0644<\/li>\n\n\n\n<li>\u0645\u0647\u0644 \u0632\u0645\u0646\u064a\u0629 \u0637\u0648\u064a\u0644\u0629 (16-20 \u0623\u0633\u0628\u0648\u0639\u064b\u0627)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0645\u0634\u0627\u0631\u064a\u0639 \u0646\u0638\u0627\u0645 \u0633\u064a\u0645\u0646\u0633 \u0627\u0644\u0625\u064a\u0643\u0648\u0644\u0648\u062c\u064a \u0627\u0644\u0643\u0628\u064a\u0631\u0629\u060c \u0648\u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0630\u0627\u062a \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0627\u0644\u062d\u0627\u0644\u064a\u0629 \u0644\u0633\u064a\u0645\u0646\u0633<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-3-volume-chinese-manufacturers\">\u0627\u0644\u0645\u0633\u062a\u0648\u0649 3: \u062d\u062c\u0645 \u0627\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u064a\u0646<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"7.-shandong-taikai-china\">7. \u0634\u0627\u0646\u062f\u0648\u0646\u063a \u062a\u0627\u064a\u0643\u0627\u064a (\u0627\u0644\u0635\u064a\u0646)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: CKG\u060c CKGB (\u0646\u0648\u0639 \u062b\u0627\u0628\u062a)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>:: 6-12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 300,000-500,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>: 4,000-4,000 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u0632\u0648\u062f Taikai \u0623\u0633\u0648\u0627\u0642 \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0628\u0643\u0645\u064a\u0627\u062a \u0643\u0628\u064a\u0631\u0629 \u0641\u064a \u0627\u0644\u0635\u064a\u0646 \u0648\u062a\u0635\u062f\u0631 \u0625\u0644\u0649 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0646 \u0627\u0644\u062f\u0648\u0644\u064a\u064a\u0646 \u0627\u0644\u062d\u0633\u0627\u0633\u064a\u0646 \u0644\u0644\u0623\u0633\u0639\u0627\u0631. \u0648\u0642\u062f \u062a\u062d\u0633\u0646\u062a \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0645\u0646\u0630 \u0639\u0627\u0645 2015 - \u0634\u0647\u0627\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639\u064a\u0629 \u0645\u0646 \u0627\u0644\u0644\u062c\u0646\u0629 \u0627\u0644\u0643\u0647\u0631\u0648\u062a\u0642\u0646\u064a\u0629 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0645\u062a\u0627\u062d\u0629 \u0627\u0644\u0622\u0646 \u0644\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0623\u0642\u0644 \u062a\u0643\u0644\u0641\u0629 \u0628\u064a\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0645\u0639\u062a\u0645\u062f\u0629 (40-60% \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 1)<\/li>\n\n\n\n<li>\u062a\u0633\u0644\u064a\u0645 \u0633\u0631\u064a\u0639 (\u0645\u0647\u0644\u0629 4 \u0623\u0633\u0627\u0628\u064a\u0639 \u0645\u0646 \u0627\u0644\u0645\u062e\u0632\u0648\u0646)<\/li>\n\n\n\n<li>\u062a\u0632\u0627\u064a\u062f \u0642\u062f\u0631\u0629 \u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0641\u0646\u064a \u0627\u0644\u0645\u062a\u0646\u0627\u0645\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062c\u0648\u062f\u0629 \u0627\u0644\u062f\u0641\u0639\u0629 \u063a\u064a\u0631 \u0627\u0644\u0645\u062a\u0633\u0642\u0629 (\u062a\u0628\u0627\u064a\u0646 \u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u00b120%)<\/li>\n\n\n\n<li>\u0633\u0644\u0633\u0644\u0629 \u062a\u0648\u0631\u064a\u062f \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u063a\u064a\u0631 \u0645\u0648\u062b\u0648\u0642\u0629 \u0644\u0644\u0639\u0645\u0644\u0627\u0621 \u0627\u0644\u062f\u0648\u0644\u064a\u064a\u0646<\/li>\n\n\n\n<li>\u062c\u0648\u062f\u0629 \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0645\u062a\u0641\u0627\u0648\u062a\u0629 (\u0628\u0639\u0636 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0645\u0648\u062b\u0642\u0629 \u0628\u0634\u0643\u0644 \u062c\u064a\u062f\u060c \u0648\u0627\u0644\u0628\u0639\u0636 \u0627\u0644\u0622\u062e\u0631 \u0645\u062a\u0646\u0627\u062b\u0631)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0630\u0627\u062a \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629\u060c \u0648\u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0627\u0644\u0635\u064a\u0646\u064a\u064a\u0646 \u0627\u0644\u0645\u062d\u0644\u064a\u064a\u0646\u060c \u0648\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u062d\u0631\u062c\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"8.-nanjing-electric-china\">8. \u0646\u0627\u0646\u062c\u064a\u0646\u063a \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0627\u0644\u0635\u064a\u0646)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: JN15\u060c JN27 (\u0646\u0648\u0639 \u0627\u0644\u0642\u0637\u0628 \u0627\u0644\u0645\u062f\u0645\u062c)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>: 12-27.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 500,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>: 5,000 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u062d\u062a\u0644 \u0634\u0631\u0643\u0629 \u0646\u0627\u0646\u062c\u064a\u0646\u063a \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0627\u0644\u0645\u0639\u0631\u0648\u0641\u0629 \u0633\u0627\u0628\u0642\u064b\u0627 \u0628\u0627\u0633\u0645 \u0646\u0627\u0646\u062c\u064a\u0646\u063a \u0644\u0644\u0623\u062a\u0645\u062a\u0629) \u0645\u0643\u0627\u0646\u0629 \u0639\u0631\u064a\u0642\u0629 \u0641\u064a \u0642\u0637\u0627\u0639 \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0635\u064a\u0646\u064a\u0629. \u062a\u0633\u062a\u0647\u062f\u0641 \u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u0645\u0642\u0627\u0648\u0644\u064a\u0646 \u0643\u0647\u0631\u0628\u0629 \u0627\u0644\u0633\u0643\u0643 \u0627\u0644\u062d\u062f\u064a\u062f\u064a\u0629 \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0639\u062a\u0645\u0627\u062f \u0627\u0644\u0633\u0643\u0643 \u0627\u0644\u062d\u062f\u064a\u062f\u064a\u0629 (\u0645\u0639\u0627\u064a\u064a\u0631 TB\/T) \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062c\u0631<\/li>\n\n\n\n<li>\u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u062a\u0648\u0631\u064a\u062f \u0627\u0644\u0645\u0646\u0634\u0623\u0629 \u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0634\u0628\u0643\u0629 \u0627\u0644\u062d\u0643\u0648\u0645\u064a\u0629 \u0627\u0644\u0635\u064a\u0646\u064a\u0629<\/li>\n\n\n\n<li>\u062a\u0633\u0639\u064a\u0631 \u0645\u0639\u062a\u062f\u0644 (30% \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 1\u060c 20% \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u0629 \u0627\u0644\u0639\u0627\u0645\u0629)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u0633\u0648\u0642 \u0627\u0644\u062a\u0635\u062f\u064a\u0631 \u0645\u062d\u062f\u0648\u062f (\u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0644\u0635\u064a\u0646 \u0627\u0644\u0645\u062d\u0644\u064a\u0629)<\/li>\n\n\n\n<li>\u0636\u0639\u0641 \u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0641\u0646\u064a \u0628\u0627\u0644\u0644\u063a\u0629 \u0627\u0644\u0625\u0646\u062c\u0644\u064a\u0632\u064a\u0629<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0639\u0646\u062f \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0633\u0643\u0643 \u0627\u0644\u062d\u062f\u064a\u062f\u064a\u0629 \u0627\u0644\u0635\u064a\u0646\u064a\u0629\u060c \u0648\u0645\u0642\u0627\u0648\u0644\u0648 \u0627\u0644\u0634\u0628\u0643\u0629 \u0627\u0644\u062d\u0643\u0648\u0645\u064a\u0629\u060c \u0648\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u062c\u0631 \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0644\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"9.-hubbell-usa\">9. \u0647\u0628\u0644 (\u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: SCC (\u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0629)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>:: 2.4-15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>:: 250,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>: 5,000 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u062e\u062f\u0645 Hubbell \u0627\u0644\u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0629 \u0641\u064a \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0629 \u0644\u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u062e\u0637\u0631\u0629 (\u0627\u0644\u0641\u0626\u0629 \u0627\u0644\u0623\u0648\u0644\u0649 \u0627\u0644\u0642\u0633\u0645 2) \u0648\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0634\u062f\u064a\u062f\u0629 \u0627\u0644\u062a\u062d\u0645\u0644.<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0642\u0627\u0626\u0645\u0629 UL \u0644\u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u062e\u0637\u0631\u0629 (\u0627\u0644\u0646\u0641\u0637 \u0648\u0627\u0644\u063a\u0627\u0632\u060c \u0627\u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0643\u064a\u0645\u064a\u0627\u0626\u064a\u0629)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0641\u064a \u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629 (\u0645\u0647\u0644 \u0632\u0645\u0646\u064a\u0629 \u0623\u0642\u0635\u0631 \u0644\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0645\u062d\u0644\u064a\u0629)<\/li>\n\n\n\n<li>\u0639\u0644\u0627\u0642\u0627\u062a \u0642\u0648\u064a\u0629 \u0641\u064a \u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0642\u062f\u0631\u0629 \u062a\u062d\u0645\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u0646\u0627\u0641\u0633\u064a\u0646 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u064a\u0646<\/li>\n\n\n\n<li>\u062a\u0643\u0644\u0641\u0629 \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0627\u0644\u0622\u0633\u064a\u0648\u064a\u064a\u0646 \u062f\u0648\u0646 \u0623\u0646 \u064a\u062a\u0646\u0627\u0633\u0628 \u0630\u0644\u0643 \u0645\u0639 \u0645\u064a\u0632\u0629 \u0627\u0644\u0623\u062f\u0627\u0621<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0648\u0641\u0631 \u0627\u0644\u062f\u0648\u0644\u064a \u0627\u0644\u0645\u062d\u062f\u0648\u062f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u062e\u0637\u0631\u0629 \u0641\u064a \u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629\u060c \u0648\u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u062e\u0627\u0636\u0639\u0629 \u0644\u062a\u0646\u0638\u064a\u0645 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0635\u062d\u0629 \u0627\u0644\u0645\u0647\u0646\u064a\u062a\u064a\u0646\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u0634\u0631\u0627\u0621 \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0645\u062d\u0644\u064a\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"10.-toshiba-japan\">10. \u062a\u0648\u0634\u064a\u0628\u0627 (\u0627\u0644\u064a\u0627\u0628\u0627\u0646)<\/h3>\n\n\n\n<p><strong>\u062e\u0637\u0648\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/strong>: VK (\u0633\u0644\u0633\u0644\u0629 \u0642\u062f\u064a\u0645\u0629\u060c \u0625\u0646\u062a\u0627\u062c \u0645\u062d\u062f\u0648\u062f)<br><strong>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/strong>:: 7.2 - 24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<br><strong>\u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: 300,000 \u0639\u0645\u0644\u064a\u0629<br><strong>\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a (AC-4)<\/strong>:: 000 6 \u0639\u0645\u0644\u064a\u0629<\/p>\n\n\n\n<p>\u062a\u0648\u0642\u0641\u062a \u062a\u0648\u0634\u064a\u0628\u0627 \u0639\u0646 \u062a\u0637\u0648\u064a\u0631 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0627\u0644\u0646\u0634\u0637\u0629 \u0641\u064a \u0639\u0627\u0645 2018\u060c \u0645\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u0645\u0646\u062a\u062c\u0627\u062a VCB \u0648 GIS. \u0644\u0627 \u062a\u0632\u0627\u0644 \u0642\u0648\u0627\u0637\u0639 VK \u0627\u0644\u062d\u0627\u0644\u064a\u0629 \u0645\u062f\u0639\u0648\u0645\u0629 \u0644\u0644\u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u0645\u062b\u0628\u062a\u0629 \u0648\u0644\u0643\u0646 \u0627\u0644\u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u0644\u062c\u062f\u064a\u062f\u0629 \u062a\u0633\u062a\u062e\u062f\u0645 \u0642\u0648\u0627\u0637\u0639 \u062e\u0627\u0631\u062c\u064a\u0629 (\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0643\u0648\u0646 LS Electric OEM).<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0633\u0645\u0639\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0627\u0644\u064a\u0627\u0628\u0627\u0646\u064a\u0629 (\u0645\u0646\u062a\u062c\u0627\u062a \u064a\u0627\u0628\u0627\u0646\u064a\u0629 \u0630\u0627\u062a \u062c\u0648\u062f\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0643\u0627\u0645\u0644 \u0645\u0639 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 Toshiba GIS\/VCB<\/li>\n\n\n\n<li>\u0642\u0627\u0639\u062f\u0629 \u0642\u0648\u064a\u0629 \u0645\u062b\u0628\u062a\u0629 \u0641\u064a \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u064a\u0627\u0628\u0627\u0646\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0648\u0642\u0641 \u062e\u0637 \u0627\u0644\u0625\u0646\u062a\u0627\u062c (\u0627\u0646\u062e\u0641\u0627\u0636 \u062a\u0648\u0627\u0641\u0631 \u0627\u0644\u0623\u062c\u0632\u0627\u0621)<\/li>\n\n\n\n<li>\u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u0637\u0648\u064a\u0631 \u062c\u062f\u064a\u062f \u0623\u0648 \u062a\u062d\u062f\u064a\u062b\u0627\u062a \u062a\u0635\u0645\u064a\u0645 \u062c\u062f\u064a\u062f\u0629<\/li>\n\n\n\n<li>\u0623\u0633\u0639\u0627\u0631 \u0645\u0645\u064a\u0632\u0629 \u0628\u062f\u0648\u0646 \u0645\u064a\u0632\u0629 \u062a\u0646\u0627\u0641\u0633\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/strong>: \u0628\u062f\u0627\u0626\u0644 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0646 \u062a\u0648\u0634\u064a\u0628\u0627\u060c \u0627\u0644\u0633\u0648\u0642 \u0627\u0644\u0645\u062d\u0644\u064a\u0629 \u0627\u0644\u064a\u0627\u0628\u0627\u0646\u064a\u0629 \u0641\u0642\u0637<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02.webp\" alt=\"\u0645\u0635\u0641\u0648\u0641\u0629 \u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u064a\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062a\u064a \u062a\u0648\u0636\u062d \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0648\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0627\u0644\u062a\u0633\u0639\u064a\u0631 \u0648\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\" class=\"wp-image-2389\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0627\u0644\u0634\u0643\u0644 02: \u0645\u0635\u0641\u0648\u0641\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u064a \u062a\u0642\u0627\u0631\u0646 \u0628\u064a\u0646 10 \u0634\u0631\u0643\u0627\u062a \u0645\u0635\u0646\u0639\u0629 \u0639\u0628\u0631 \u0645\u0639\u0627\u064a\u064a\u0631 \u062d\u0627\u0633\u0645\u0629 - \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u0648\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a AC-4\u060c \u0648\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0633\u0639\u0631\u064a\u060c \u0648\u062a\u0648\u0627\u0641\u0631 \u0634\u0628\u0643\u0629 \u0627\u0644\u062e\u062f\u0645\u0629.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-decision-matrix\">\u0645\u0635\u0641\u0648\u0641\u0629 \u0642\u0631\u0627\u0631 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631<\/h2>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u062d\u0631\u062c\u0629 (\u0627\u0644\u0646\u0648\u0648\u064a\u0629 \u0648\u0627\u0644\u0628\u062d\u0631\u064a\u0629 \u0648\u0627\u0644\u0646\u0641\u0637 \u0648\u0627\u0644\u063a\u0627\u0632)<\/strong><br>\u2192 ABB\u060c \u0634\u0646\u0627\u064a\u062f\u0631\u060c \u0625\u064a\u062a\u0648\u0646<br>\u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629: \u0623\u0642\u0635\u0649 \u0642\u062f\u0631 \u0645\u0646 \u0627\u0644\u062a\u062d\u0645\u0644 \u0648\u0627\u0644\u062e\u062f\u0645\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0648\u0627\u0644\u0634\u0647\u0627\u062f\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629<br>\u0642\u0628\u0648\u0644: 30-40% \u0639\u0644\u0627\u0648\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0635\u0646\u0627\u0639\u064a (\u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0627\u0644\u0645\u064a\u0627\u0647 \u0648\u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0648\u0627\u0644\u062a\u0643\u064a\u064a\u0641)<\/strong><br>\u2192 XBRELE\u060c LS Electric\u060c Siemens<br>\u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629: \u0627\u0644\u0645\u0648\u0627\u0632\u0646\u0629 \u0628\u064a\u0646 \u0627\u0644\u062a\u0643\u0644\u0641\u0629\/\u0627\u0644\u0623\u062f\u0627\u0621\u060c \u0648\u0627\u0644\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 IEC\u060c \u0648\u0627\u0644\u062a\u062e\u0635\u064a\u0635<br>\u0627\u0642\u0628\u0644: \u0645\u0647\u0644\u0629 \u0632\u0645\u0646\u064a\u0629 \u0645\u0639\u062a\u062f\u0644\u0629<\/p>\n\n\n\n<p><strong>\u062a\u0643\u0627\u0645\u0644 \u0644\u0648\u062d\u0629 \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 (\u062d\u062c\u0645 \u0643\u0628\u064a\u0631)<\/strong><br>\u2192 XBRELE\u060c \u062a\u0627\u064a\u0643\u0627\u064a\u060c \u0646\u0627\u0646\u062c\u064a\u0646\u063a \u0625\u0644\u0643\u062a\u0631\u064a\u0643<br>\u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629: \u0627\u0644\u062a\u0633\u0639\u064a\u0631 \u0627\u0644\u0645\u0628\u0627\u0634\u0631 \u0645\u0646 \u0627\u0644\u0645\u0635\u0646\u0639\u060c \u0648\u0633\u0631\u0639\u0629 \u0627\u0644\u0625\u0646\u062c\u0627\u0632\u060c \u0648\u0645\u0631\u0648\u0646\u0629 \u0627\u0644\u062a\u0635\u0645\u064a\u0645<br>\u0642\u0628\u0648\u0644: \u0645\u062e\u0632\u0648\u0646 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u0645\u062f\u0627\u0631\u0629 \u0630\u0627\u062a\u064a\u064b\u0627<\/p>\n\n\n\n<p><strong>\u0645\u0642\u064a\u062f\u0629 \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629\/\u063a\u064a\u0631 \u062d\u0631\u062c\u0629<\/strong><br>\u2192 \u062a\u0627\u064a\u0643\u0627\u064a\u060c \u0647\u0627\u0628\u0644 (\u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629 \u0641\u0642\u0637)<br>\u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629: \u0623\u0642\u0644 \u062a\u0643\u0644\u0641\u0629 \u0623\u0648\u0644\u064a\u0629<br>\u0627\u0644\u0642\u0628\u0648\u0644: \u0635\u064a\u0627\u0646\u0629 \u062f\u0648\u0631\u0629 \u062d\u064a\u0627\u0629 \u0623\u0639\u0644\u0649\u060c \u0648\u062f\u0639\u0645 \u0641\u0646\u064a \u0645\u062d\u062f\u0648\u062f<\/p>\n\n\n\n<p>\u0623\u0638\u0647\u0631\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u064a \u0623\u062c\u0631\u064a\u062a \u0639\u0644\u0649 \u0623\u0643\u062b\u0631 \u0645\u0646 200 \u0645\u0646\u0634\u0623\u0629 \u0623\u0646 \u0645\u0637\u0627\u0628\u0642\u0629 \u0641\u0626\u0629 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0639 \u0623\u0647\u0645\u064a\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u062a\u0642\u0644\u0644 \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u063a\u064a\u0631 \u0627\u0644\u0645\u062e\u0637\u0637 \u0644\u0647 40% \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062a\u0637\u0627\u0628\u0642\u0629 (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c \u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 3 \u0641\u064a \u062a\u0637\u0628\u064a\u0642 \u0631\u0627\u0641\u0639\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u062d\u0631\u062c\u0629).<\/p>\n\n\n\n<p>\u0644\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a\u0629 \u0628\u064a\u0646&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/vacuum-vs-air-contactor-mining-safety-jcz-upgrade-benefits\/\">\u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/a>, \u060c \u062a\u064f\u0638\u0647\u0631 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0645\u0632\u0627\u064a\u0627 \u062a\u0642\u0646\u064a\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0641\u064a \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-procurement-mistakes\">\u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0641\u064a \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a<\/h2>\n\n\n\n<p><strong>\u0627\u0644\u062e\u0637\u0623 #1: \u0627\u0644\u0623\u0642\u0644 \u0633\u0639\u0631\u0627\u064b \u064a\u0641\u0648\u0632<\/strong><\/p>\n\n\n\n<p>\u0625\u0646 \u0637\u0644\u0628 \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u0630\u064a \u064a\u062d\u062f\u062f \u201c12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 400 \u0623\u0645\u0628\u064a\u0631\u060c \u0645\u0644\u0627\u0645\u0633 \u062a\u0641\u0631\u064a\u063a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 4 AC-4\u201d \u0628\u062f\u0648\u0646 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\/\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u064a\u062f\u0639\u0648 \u0625\u0644\u0649 \u0643\u0648\u0627\u0631\u062b \u0623\u0642\u0644 \u0627\u0644\u0639\u0637\u0627\u0621\u0627\u062a \u062a\u0643\u0644\u0641\u0629. \u064a\u0643\u0644\u0641 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u0630\u064a \u062a\u0628\u0644\u063a \u062a\u0643\u0644\u0641\u062a\u0647 300,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644 401 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a \u0623\u0642\u0644 \u0645\u0646 \u0648\u062d\u062f\u0629 \u062a\u0634\u063a\u064a\u0644 1,000,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644 - \u0648\u0644\u0643\u0646\u0647 \u064a\u062a\u0637\u0644\u0628 \u0635\u064a\u0627\u0646\u0629 \u0623\u0643\u062b\u0631 3.3 \u0645\u0631\u0629 \u0623\u0643\u062b\u0631.<\/p>\n\n\n\n<p><strong>\u0625\u0635\u0644\u0627\u062d<\/strong>: \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0644\u062a\u062d\u0645\u0644:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u064b\u0627: \u2265 500,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644 \u062d\u0633\u0628 IEC 62271-106 \u0627\u0644\u0641\u0626\u0629 M1\u201d<\/li>\n\n\n\n<li>\u201cAC-4 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629: \u22656,000 \u0639\u0645\u0644\u064a\u0629 \u0639\u0646\u062f 400 \u0623\u0645\u0628\u064a\u0631\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062e\u0637\u0623 #2: \u062a\u062c\u0627\u0647\u0644 \u0645\u0647\u0644\u0629 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062e\u062f\u0645\u0629<\/strong><\/p>\n\n\n\n<p>\u062a\u062a\u0633\u0628\u0628 \u0645\u0647\u0644\u0629 40 \u0623\u0633\u0628\u0648\u0639\u064b\u0627 \u0627\u0644\u062a\u064a \u062a\u0633\u062a\u063a\u0631\u0642\u0647\u0627 \u0625\u062d\u062f\u0649 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629 \u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0641\u064a \u0645\u062e\u0627\u0637\u0631 \u062a\u0639\u0637\u0644 \u063a\u064a\u0631 \u0645\u0642\u0628\u0648\u0644\u0629 \u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0646\u0627\u0626\u064a\u0629. \u064a\u062c\u0628 \u0639\u0644\u0649 \u0635\u0627\u0646\u0639\u064a \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u062a\u062e\u0632\u064a\u0646 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u062d\u0631\u062c\u0629 \u0645\u0633\u0628\u0642\u064b\u0627 \u0623\u0648 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0627\u0644\u0630\u064a\u0646 \u0644\u062f\u064a\u0647\u0645 \u0642\u0637\u0639 \u063a\u064a\u0627\u0631 \u0645\u062a\u0648\u0641\u0631\u0629 \u0644\u0645\u062f\u0629 \u062a\u0642\u0644 \u0639\u0646 4 \u0623\u0633\u0627\u0628\u064a\u0639.<\/p>\n\n\n\n<p><strong>\u0625\u0635\u0644\u0627\u062d<\/strong>: \u062a\u0636\u0645\u064a\u0646 \u062a\u0642\u064a\u064a\u0645 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u062a\u0648\u0641\u064a\u0631 \u0645\u0647\u0644\u0629 \u0632\u0645\u0646\u064a\u0629 \u0627\u062d\u062a\u064a\u0627\u0637\u064a\u0629 \u0644\u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 VI \u0648\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0643\u0645\u064a\u0629 \u0627\u0644\u0637\u0644\u0628\u201d<\/li>\n\n\n\n<li>\u201c\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u0643\u0632 \u0627\u0644\u062e\u062f\u0645\u0629 \u0627\u0644\u0625\u0642\u0644\u064a\u0645\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0642\u0639 \u0639\u0644\u0649 \u0628\u0639\u062f 500 \u0643\u0645 \u0645\u0646 \u0627\u0644\u0645\u0648\u0642\u0639\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062e\u0637\u0623 #3: \u0646\u0633\u062e \u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0644\u0644\u0645\u0646\u0627\u0641\u0633 \u062f\u0648\u0646 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0635\u062d\u062a\u0647\u0627<\/strong><\/p>\n\n\n\n<p>\u201c\u0627\u0644\u0645\u0646\u0627\u0641\u0633 X \u064a\u0633\u062a\u062e\u062f\u0645 ABB\u060c \u0644\u0630\u0627 \u0633\u0646\u0633\u062a\u062e\u062f\u0645 \u0646\u062d\u0646 \u0623\u064a\u0636\u064b\u0627\u201d \u064a\u062a\u062c\u0627\u0647\u0644 \u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u0627\u0644\u062a\u0637\u0628\u064a\u0642. \u0625\u0630\u0627 \u0643\u0627\u0646 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0646\u0627\u0641\u0633 50 \u0639\u0645\u0644\u064a\u0629\/\u064a\u0648\u0645\u064a\u064b\u0627 \u0648\u062a\u0637\u0628\u064a\u0642\u0643 300 \u0639\u0645\u0644\u064a\u0629\/\u064a\u0648\u0645\u064a\u064b\u0627 \u0641\u0623\u0646\u062a \u0628\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0641\u0626\u0627\u062a \u062a\u062d\u0645\u0644 \u0645\u062e\u062a\u0644\u0641\u0629 - \u0645\u0645\u0627 \u064a\u0628\u0631\u0631 \u0627\u062d\u062a\u0645\u0627\u0644 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0646\u0627\u0641\u0633 \u0644\u0644\u0645\u0633\u062a\u0648\u0649 1 \u0627\u0644\u0645\u062a\u0645\u064a\u0632 \u062d\u064a\u062b \u064a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0645\u0646\u0627\u0641\u0633 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 2.<\/p>\n\n\n\n<p><strong>\u0625\u0635\u0644\u0627\u062d<\/strong>: \u0625\u062c\u0631\u0627\u0621 \u062a\u062d\u0644\u064a\u0644 \u062f\u0648\u0631\u0629 \u0627\u0644\u0639\u0645\u0644:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u062d\u0633\u0628 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0633\u0646\u0648\u064a\u0629: \u062f\u0648\u0631\u0627\u062a\/\u064a\u0648\u0645 \u00d7 365 \u062f\u0648\u0631\u0629\/\u064a\u0648\u0645 \u00d7 365<\/li>\n\n\n\n<li>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0627\u0644\u0645\u0637\u0644\u0648\u0628: (\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u00d7 \u0633\u0646\u0648\u0627\u062a \u0627\u0644\u0641\u062a\u0631\u0629 \u0627\u0644\u0645\u0633\u062a\u0647\u062f\u0641\u0629)<\/li>\n\n\n\n<li>\u0645\u0637\u0627\u0628\u0642\u0629 \u0641\u0626\u0629 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0639 \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u062d\u0633\u0648\u0628\u0629<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0627\u0644\u062e\u0644\u0627\u0635\u0629<\/h2>\n\n\n\n<p>\u064a\u062d\u062f\u062f \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0645\u0628\u0627\u0634\u0631\u0629\u064b \u062a\u0643\u0644\u0641\u0629 \u062f\u0648\u0631\u0629 \u0627\u0644\u062d\u064a\u0627\u0629 \u0648\u0639\u0628\u0621 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629 \u0639\u0644\u0649 \u0645\u062f\u0649 15-25 \u0633\u0646\u0629 \u0645\u0646 \u0639\u0645\u0631 \u0627\u0644\u062e\u062f\u0645\u0629. \u062a\u0648\u0641\u0631 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 (ABB\u060c \u0634\u0646\u0627\u064a\u062f\u0631\u060c \u0625\u064a\u062a\u0648\u0646) \u0623\u0642\u0635\u0649 \u0642\u062f\u0631 \u0645\u0646 \u0627\u0644\u062a\u062d\u0645\u0644 \u0648\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0639\u0627\u0644\u0645\u064a \u0628\u0623\u0633\u0639\u0627\u0631 \u0645\u062a\u0645\u064a\u0632\u0629 30-40%. \u064a\u0648\u0627\u0632\u0646 \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0648\u0646 \u0641\u064a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 (XBRELE\u060c LS Electric) \u0628\u064a\u0646 \u0627\u0644\u0623\u062f\u0627\u0621 \u0648\u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629. \u0648\u064a\u062e\u062f\u0645 \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u0648\u0646 \u0630\u0648\u0648 \u0627\u0644\u062d\u062c\u0645 \u0627\u0644\u0643\u0628\u064a\u0631 (\u062a\u0627\u064a\u0643\u0627\u064a\u060c \u0646\u0627\u0646\u062c\u064a\u0646\u063a) \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0646 \u0630\u0648\u064a \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629 \u0627\u0644\u0645\u0633\u062a\u0639\u062f\u064a\u0646 \u0644\u0642\u0628\u0648\u0644 \u0641\u062a\u0631\u0627\u062a \u0635\u064a\u0627\u0646\u0629 \u0623\u0639\u0644\u0649.<\/p>\n\n\n\n<p>\u062a\u0639\u062a\u0645\u062f \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u201c\u0627\u0644\u0635\u062d\u064a\u062d\u0629\u201d \u0639\u0644\u0649 \u0623\u0647\u0645\u064a\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0648\u062f\u0648\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629 - \u0648\u0644\u064a\u0633 \u0633\u0639\u0631 \u0627\u0644\u0634\u0631\u0627\u0621 \u0627\u0644\u0623\u0648\u0644\u064a \u0648\u062d\u062f\u0647. \u0625\u0646 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 $2,000 \u0627\u0644\u0630\u064a \u064a\u062a\u0637\u0644\u0628 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0643\u0644 7 \u0633\u0646\u0648\u0627\u062a \u064a\u0643\u0644\u0641 \u0623\u0643\u062b\u0631 \u0639\u0644\u0649 \u0645\u062f\u0649 25 \u0639\u0627\u0645\u064b\u0627 \u0645\u0646 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 $3,500 \u0627\u0644\u0630\u064a \u064a\u062f\u0648\u0645 15 \u0639\u0627\u0645\u064b\u0627\u060c \u062d\u062a\u0649 \u0642\u0628\u0644 \u0627\u062d\u062a\u0633\u0627\u0628 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0648\u0627\u0644\u0639\u0645\u0627\u0644\u0629.<\/p>\n\n\n\n<p>\u0645\u0637\u0627\u0628\u0642\u0629 \u0641\u0626\u0629 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0639 \u0639\u0648\u0627\u0642\u0628 \u0627\u0644\u0641\u0634\u0644: \u062a\u0628\u0631\u0631 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u062d\u0631\u062c\u0629 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u062a\u0645\u064a\u0632\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u062a\u062d\u0645\u0644 \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u063a\u064a\u0631 \u0627\u0644\u062d\u0631\u062c\u0629 \u0630\u0627\u062a \u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u0645\u062a\u0642\u0637\u0639\u0629 \u0627\u0644\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0627\u0642\u062a\u0635\u0627\u062f\u064a\u0629. \u0627\u0644\u0642\u0631\u0627\u0631 \u0627\u0644\u0623\u0633\u0648\u0623 \u0647\u0648 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 3 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629 \u0623\u0648 \u0627\u0644\u062f\u0641\u0639 \u0627\u0644\u0632\u0627\u0626\u062f \u0644\u0644\u0645\u0633\u062a\u0648\u0649 1 \u0641\u064a \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u062d\u0631\u062c\u0629 - \u0643\u0644\u0627\u0647\u0645\u0627 \u064a\u0647\u062f\u0631 \u0627\u0644\u0645\u0627\u0644\u060c \u0648\u0644\u0643\u0646 \u0641\u064a \u0627\u062a\u062c\u0627\u0647\u064a\u0646 \u0645\u062e\u062a\u0644\u0641\u064a\u0646.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vacuum-contactor-manufacturers\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629: \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0650\u0651\u0639\u0629 \u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0626\u064a<\/h2>\n\n\n\n<p><strong>\u0627\u0644\u0633\u0624\u0627\u0644 1: \u0645\u0627 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0644\u0627\u0642\u0637 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 \u0648\u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u064a\u0646\u064a\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0644\u0627\u0642\u0637 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u061f<\/strong><\/p>\n\n\n\n<p>\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u062a\u0642\u062f\u0645 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 (ABB\u060c \u0634\u0646\u0627\u064a\u062f\u0631\u060c \u0625\u064a\u062a\u0648\u0646) 1,000,000 \u0639\u0645\u0644\u064a\u0629 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629\u060c \u06488,000-12,000 \u062f\u0648\u0631\u0629 AC-4 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u0648\u0648\u062b\u0627\u0626\u0642 \u0634\u0627\u0645\u0644\u0629 \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639 \u0645\u0646 \u0645\u062e\u062a\u0628\u0631\u0627\u062a \u0645\u0639\u062a\u0645\u062f\u0629 (KEMA\u060c CPRI)\u060c \u0648\u0634\u0628\u0643\u0627\u062a \u062e\u062f\u0645\u0629 \u0639\u0627\u0644\u0645\u064a\u0629 \u0645\u0639 \u062a\u0648\u0635\u064a\u0644 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0641\u064a \u0623\u0642\u0644 \u0645\u0646 48 \u0633\u0627\u0639\u0629. \u064a\u062a\u0631\u0627\u0648\u062d \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u0648\u0646 \u0645\u0627 \u0628\u064a\u0646 \u0645\u062a\u062e\u0635\u0635\u064a\u0646 \u0641\u064a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0645\u062b\u0644 XBRELE (1 \u0645\u0644\u064a\u0648\u0646 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u06488000 \u062f\u0648\u0631\u0629 AC-4\u060c \u0645\u0639\u062a\u0645\u062f\u0629 \u0645\u0646 IEC) \u0645\u0639 \u062a\u0648\u0641\u064a\u0631 30-50%\u060c \u0648\u0645\u0648\u0631\u062f\u064a \u0627\u0644\u062d\u062c\u0645 (300000 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u06484000 AC-4) \u0645\u0639 \u062a\u0648\u0641\u064a\u0631 50-60% \u0648\u0644\u0643\u0646 \u0645\u0639 \u0645\u0631\u0627\u0642\u0628\u0629 \u062c\u0648\u062f\u0629 \u063a\u064a\u0631 \u0645\u062a\u0633\u0642\u0629. \u0648\u0642\u062f \u0636\u0627\u0642\u062a \u0627\u0644\u0641\u062c\u0648\u0629 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 - \u062a\u062a\u0637\u0627\u0628\u0642 \u0627\u0644\u0622\u0646 \u0623\u0639\u0644\u0649 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u064a\u0646\u064a\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0645\u0639 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 \u0645\u0639 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0632\u0627\u064a\u0627 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0645\u0628\u064a\u0639\u0627\u062a \u0627\u0644\u0645\u0628\u0627\u0634\u0631\u0629 \u0644\u0644\u0645\u0635\u0646\u0639 \u0648\u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0622\u0633\u064a\u0648\u064a.<\/p>\n\n\n\n<p><strong>\u06332: \u0643\u064a\u0641 \u064a\u0645\u0643\u0646\u0646\u064a \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0627\u0644\u0645\u0632\u0639\u0648\u0645 \u0644\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629\u061f<\/strong><\/p>\n\n\n\n<p>\u0627\u0637\u0644\u0628 \u0634\u0647\u0627\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 IEC 62271-106\u060c \u0648\u0644\u064a\u0633 \u0641\u0642\u0637 \u0625\u0639\u0644\u0627\u0646\u0627\u062a \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644. \u064a\u062c\u0628 \u0623\u0646 \u062a\u064f\u0638\u0647\u0631 \u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a: (1) \u0627\u0633\u0645 \u0645\u062e\u062a\u0628\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u0627\u0639\u062a\u0645\u0627\u062f (KEMA\u060c CESI\u060c CPRI\u060c \u0645\u0639\u062a\u0645\u062f \u0645\u0646 NEMA)\u060c (2) \u0639\u062f\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0641\u0639\u0644\u064a \u0627\u0644\u0630\u064a \u062a\u0645 \u062a\u062d\u0642\u064a\u0642\u0647 \u0623\u062b\u0646\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u062d\u0645\u0644\u060c (3) \u0638\u0631\u0648\u0641 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 (\u0627\u0644\u062c\u0647\u062f\u060c \u0627\u0644\u062a\u064a\u0627\u0631\u060c \u062f\u0648\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644)\u060c (4) \u062a\u0627\u0631\u064a\u062e \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 (\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a \u0627\u0644\u062a\u064a \u064a\u0632\u064a\u062f \u0639\u0645\u0631\u0647\u0627 \u0639\u0646 10 \u0633\u0646\u0648\u0627\u062a \u0642\u062f \u0644\u0627 \u062a\u0639\u0643\u0633 \u0627\u0644\u0625\u0646\u062a\u0627\u062c \u0627\u0644\u062d\u0627\u0644\u064a). \u062a\u062d\u0642\u0642 \u0645\u0646 \u0646\u0637\u0627\u0642 \u0627\u0644\u0645\u062e\u062a\u0628\u0631 \u0645\u0628\u0627\u0634\u0631\u0629 \u0641\u064a \u0645\u0631\u0641\u0642\u0627\u062a \u0627\u0644\u0634\u0647\u0627\u062f\u0629 \u0648\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u062c\u0647\u0629 \u0627\u0644\u0645\u0635\u062f\u0631\u0629 \u0644\u0644\u0634\u0647\u0627\u062f\u0629. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629\u060c \u0627\u0637\u0644\u0628 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u0635\u0646\u0639 \u0627\u0644\u0645\u0634\u0647\u0648\u062f\u0629 (FAT) \u062d\u064a\u062b \u064a\u0631\u0627\u0642\u0628 \u0627\u0644\u0645\u0641\u062a\u0634 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0627\u0644\u0645\u062a\u0633\u0627\u0631\u0639 \u0639\u0644\u0649 \u0648\u062d\u062f\u0627\u062a\u0643 \u0627\u0644\u0645\u062d\u062f\u062f\u0629. \u0644\u0642\u062f \u0642\u0645\u0646\u0627 \u0628\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u0628\u0627\u064a\u0646 40% \u0628\u064a\u0646 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0627\u0644\u0645\u0637\u0627\u0644\u0628 \u0628\u0647 \u0648\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0641\u0639\u0644\u064a \u0641\u064a \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u0639\u062a\u0645\u062f\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0642\u0644.<\/p>\n\n\n\n<p><strong>\u06333: \u0647\u0644 \u064a\u0645\u0643\u0646\u0646\u064a \u0645\u0632\u062c \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621 \u0645\u0646 \u062c\u0647\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0645\u062e\u062a\u0644\u0641\u0629 \u0641\u064a \u0627\u0644\u0644\u0648\u062d\u0629 \u0646\u0641\u0633\u0647\u0627\u061f<\/strong><\/p>\n\n\n\n<p>\u0646\u0639\u0645\u060c \u0648\u0644\u0643\u0646 \u0645\u0639 \u062a\u0648\u062e\u064a \u0627\u0644\u062d\u0630\u0631 \u0641\u064a \u062b\u0644\u0627\u062b \u0646\u0642\u0627\u0637: (1)&nbsp;<strong>\u062a\u0648\u0627\u0641\u0642 \u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u062a\u0648\u0627\u0641\u0642<\/strong>-\u062a\u062d\u0642\u0642 \u0645\u0646 \u062a\u0637\u0627\u0628\u0642 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0645\u0644\u0641 (110 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f\u060c 220 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f\u060c \u0625\u0644\u062e) \u0648\u0627\u0633\u062a\u0647\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0641\u064a \u062d\u062f\u0648\u062f \u0642\u062f\u0631\u0629 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645\u061b (2)&nbsp;<strong>\u0627\u0644\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0645\u0627\u062f\u064a\u0629<\/strong>-\u062a\u062e\u062a\u0644\u0641 \u0623\u0646\u0645\u0627\u0637 \u062b\u0642\u0648\u0628 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062e\u0644\u0648\u0635 \u062d\u0633\u0628 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629\u060c \u0645\u0645\u0627 \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0635\u062d\u0629 \u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0644\u0648\u062d\u0629\u061b (3)&nbsp;<strong>\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629<\/strong>-\u062a\u062e\u062a\u0644\u0641 \u0643\u0645\u064a\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 (NO\/NC) \u0648\u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u062d\u0627\u0644\u064a\u0629\u061b \u0641\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u062a\u0635\u0645\u064a\u0645 \u062a\u0644\u0627\u0645\u0633 10 \u0623\u0645\u0628\u064a\u0631 \u0641\u064a \u062a\u0637\u0628\u064a\u0642 \u064a\u062a\u0637\u0644\u0628 15 \u0623\u0645\u0628\u064a\u0631 \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644. \u064a\u0639\u0645\u0644 \u0627\u0644\u062a\u0648\u062d\u064a\u062f \u0627\u0644\u0642\u064a\u0627\u0633\u064a \u0639\u0644\u0649 \u062c\u0647\u0629 \u062a\u0635\u0646\u064a\u0639 \u0648\u0627\u062d\u062f\u0629 \u0639\u0644\u0649 \u062a\u0628\u0633\u064a\u0637 \u0645\u062e\u0632\u0648\u0646 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0648\u062a\u062f\u0631\u064a\u0628 \u0627\u0644\u0641\u0646\u064a\u064a\u0646\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u062a\u0643\u0627\u0644\u064a\u0641 \u062f\u0648\u0631\u0629 \u0627\u0644\u062d\u064a\u0627\u0629 15-20% \u0641\u064a \u062a\u062d\u0644\u064a\u0644 \u0623\u0633\u0637\u0648\u0644\u0646\u0627 \u0639\u0628\u0631 \u0623\u0643\u062b\u0631 \u0645\u0646 500 \u0645\u0646\u0634\u0623\u0629.<\/p>\n\n\n\n<p><strong>\u06334: \u0645\u0627 \u0647\u064a \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0623\u0646 \u0623\u0637\u0644\u0628\u0647\u0627 \u0645\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0644\u0645\u0641\u0631\u063a\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u061f<\/strong><\/p>\n\n\n\n<p>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0627\u0644\u0645\u0642\u0628\u0648\u0644: (1)&nbsp;<strong>\u0634\u0647\u0627\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639\u064a\u0629<\/strong>&nbsp;(IEC 62271-106 \u0623\u0648 \u0645\u0627 \u064a\u0639\u0627\u062f\u0644\u0647) \u0627\u0644\u062a\u064a \u062a\u0628\u064a\u0646 \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\/\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u061b (2)&nbsp;<strong>\u062f\u0644\u064a\u0644 \u0627\u0644\u062a\u0639\u0644\u064a\u0645\u0627\u062a<\/strong>&nbsp;\u0645\u0639 \u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u060c \u0648\u062d\u062f\u0648\u062f \u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u060c \u0648\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0639\u0632\u0645 \u0627\u0644\u062f\u0648\u0631\u0627\u0646\u061b (3)&nbsp;<strong>\u0631\u0633\u0648\u0645\u0627\u062a \u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/strong>&nbsp;(\u064a\u0641\u0636\u0644 \u062a\u0646\u0633\u064a\u0642 CAD) \u0645\u0639 \u0623\u0628\u0639\u0627\u062f \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u062e\u0644\u0648\u0635 \u0648\u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u0625\u0646\u0647\u0627\u0621\u061b (4)&nbsp;<strong>\u0642\u0627\u0626\u0645\u0629 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631<\/strong>&nbsp;\u0645\u0639 \u0623\u0631\u0642\u0627\u0645 \u0627\u0644\u0642\u0637\u0639\u060c \u0648\u0627\u0644\u0645\u0647\u0644 \u0627\u0644\u0632\u0645\u0646\u064a\u0629\u060c \u0648\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0643\u0645\u064a\u0627\u062a \u0627\u0644\u0637\u0644\u0628\u0627\u062a. \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629 \u064a\u0636\u0627\u0641: (5)&nbsp;<strong>\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 FAT\/SAT<\/strong>, (6)&nbsp;<strong>\u0648\u062b\u0627\u0626\u0642 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629<\/strong>&nbsp;(\u0634\u0647\u0627\u062f\u0629 \u0627\u0644\u0623\u064a\u0632\u0648 9001\u060c \u062a\u0642\u0627\u0631\u064a\u0631 \u0627\u0644\u062a\u0641\u062a\u064a\u0634)\u060c (7)&nbsp;<strong>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a \u0627\u0644\u0645\u0627\u062f\u064a\u0629<\/strong>&nbsp;\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (\u062a\u0631\u0643\u064a\u0628\u0629 \u0633\u0628\u064a\u0643\u0629 CuCr). \u0631\u0641\u0636 \u0627\u0644\u0639\u0637\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0641\u062a\u0642\u0631 \u0625\u0644\u0649 \u0634\u0647\u0627\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0646\u0648\u0639 - \u0644\u0627 \u064a\u0645\u0643\u0646 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u201c\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644\u201d \u0628\u062f\u0648\u0646 \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631.<\/p>\n\n\n\n<p><strong>\u06335: \u0645\u0627 \u0647\u064a \u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629\u061f<\/strong><\/p>\n\n\n\n<p>\u062a\u0633\u0639\u064a\u0631 \u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 400 \u0623\u0645\u0628\u064a\u0631\u060c AC-4 (2025): \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 (ABB\u060c \u0634\u0646\u0627\u064a\u062f\u0631) $3,500-$5,000 \u0644\u0643\u0644 \u0648\u062d\u062f\u0629\u061b \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0623\u0635\u0644\u064a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 (XBRELE\u060c LS Electric) $2,000-$3,000\u061b \u0627\u0644\u0645\u0648\u0631\u062f\u064a\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u064a\u0646 \u0645\u0646 \u0627\u0644\u062d\u062c\u0645 \u0627\u0644\u0643\u0628\u064a\u0631 $1,200-1T4T2,000. \u064a\u062a\u062f\u0631\u062c \u0627\u0644\u0633\u0639\u0631 \u0645\u0639 \u0627\u0644\u062c\u0647\u062f (24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u064a\u0643\u0644\u0641 1.5-1.8\u00d7 \u0645\u0642\u0627\u0628\u0644 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a)\u060c \u0648\u0627\u0644\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u062d\u0627\u0644\u064a (630 \u0623\u0645\u0628\u064a\u0631 \u064a\u0643\u0644\u0641 1.3-1.5\u00d7 \u0645\u0642\u0627\u0628\u0644 400 \u0623\u0645\u0628\u064a\u0631)\u060c \u0648\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u062e\u0627\u0635\u0629 (\u0642\u0627\u0628\u0644 \u0644\u0644\u0633\u062d\u0628 \u0645\u0642\u0627\u0628\u0644 \u062b\u0627\u0628\u062a: +20-30%\u060c \u062d\u0627\u0648\u064a\u0629 \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0627\u0646\u0641\u062c\u0627\u0631: +50-80%). \u062e\u0635\u0648\u0645\u0627\u062a \u0627\u0644\u0643\u0645\u064a\u0629: 10-151-15% \u0644\u0623\u0643\u062b\u0631 \u0645\u0646 5 \u0648\u062d\u062f\u0627\u062a\u060c 20-25% \u0644\u0623\u0643\u062b\u0631 \u0645\u0646 20 \u0648\u062d\u062f\u0629. \u062a\u0634\u0645\u0644 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629 \u0639\u0644\u0649 \u0645\u062f\u0649 20 \u0639\u0627\u0645\u064b\u0627 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 (\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0643\u0644 6000-10000 \u0639\u0645\u0644\u064a\u0629 AC-4 \u0628\u0633\u0639\u0631 $800-$1500 \u0644\u0643\u0644 6)\u060c \u0648\u062a\u0643\u0627\u0644\u064a\u0641 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644\u060c \u0648\u0645\u062e\u0632\u0648\u0646 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 - \u063a\u0627\u0644\u0628\u064b\u0627 2-3\u00d7 \u0633\u0639\u0631 \u0627\u0644\u0634\u0631\u0627\u0621 \u0627\u0644\u0623\u0648\u0644\u064a.<\/p>\n\n\n\n<p><strong>\u06336: \u0645\u0627 \u0647\u064a \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0630\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0642\u0627\u0633\u064a\u0629\u061f<\/strong><\/p>\n\n\n\n<p>\u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u062a\u0635\u0646\u064a\u0641 \u0636\u0645\u064a\u0645\u0629 IP54 \u0643\u062d\u062f \u0623\u062f\u0646\u0649\u060c \u0648\u0633\u062e\u0627\u0646\u0627\u062a \u0645\u0636\u0627\u062f\u0629 \u0644\u0644\u062a\u0643\u062b\u064a\u0641 \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 60068-2-6\u060c \u0648\u0634\u0647\u0627\u062f\u0629 \u0645\u062b\u0627\u0644\u064a\u0629 \u0641\u064a \u0627\u0644\u0623\u062c\u0648\u0627\u0621 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0627\u0646\u0641\u062c\u0627\u0631 (ATEX Ex d \u0623\u0648 \u0639\u0644\u0627\u0645\u0629 MA \u0627\u0644\u0635\u064a\u0646\u064a\u0629). \u0627\u0644\u0623\u0641\u0636\u0644 \u0623\u062f\u0627\u0621\u064b&nbsp;<strong>XBRELE<\/strong>&nbsp;(\u0633\u0644\u0633\u0644\u0629 JCZ \u0645\u0639 \u0634\u0647\u0627\u062f\u0629 MA\u060c \u0645\u062c\u0631\u0628\u0629 \u0645\u064a\u062f\u0627\u0646\u064a\u064b\u0627 \u0641\u064a \u0623\u0643\u062b\u0631 \u0645\u0646 200 \u0645\u0646\u062c\u0645 \u0641\u062d\u0645),&nbsp;<strong>ABB<\/strong>&nbsp;(VM1 \u0645\u0639 \u062e\u064a\u0627\u0631 IP65\u060c \u0645\u0624\u0647\u0644 \u0632\u0644\u0632\u0627\u0644\u064a),&nbsp;<strong>\u0625\u064a\u062a\u0648\u0646<\/strong>&nbsp;(VCP-W \u0645\u0639 \u0627\u062d\u062a\u0648\u0627\u0621 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629). \u062a\u0642\u062f\u0645 \u0634\u0631\u0643\u062a\u0627 LS Electric \u0648\u0634\u0646\u0627\u064a\u062f\u0631 \u0645\u062a\u063a\u064a\u0631\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0644\u0643\u0646\u0647\u0627 \u0623\u0636\u0639\u0641 \u0641\u064a \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0644\u0627\u0645\u062a\u062b\u0627\u0644 MSHA \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629 \u0623\u0648 MA \u0627\u0644\u0635\u064a\u0646\u064a\u0629. \u064a\u062c\u0628 \u062a\u062c\u0646\u0628 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0635\u064a\u0646\u064a\u0629 \u0627\u0644\u0639\u0627\u0645\u0629 - \u064a\u0633\u0645\u062d \u0627\u0644\u062e\u062a\u0645 \u063a\u064a\u0631 \u0627\u0644\u0645\u0644\u0627\u0626\u0645 \u0628\u062f\u062e\u0648\u0644 \u0627\u0644\u063a\u0628\u0627\u0631\u060c \u0645\u0645\u0627 \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u062a\u0639\u0637\u0644 \u0627\u0644\u062a\u062a\u0628\u0639 \u0641\u064a \u063a\u0636\u0648\u0646 18-36 \u0634\u0647\u0631\u064b\u0627 \u0641\u064a \u062f\u0631\u0627\u0633\u0627\u062a\u0646\u0627 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0641\u062d\u0645.<\/p>\n\n\n\n<p><strong>\u06337: \u0643\u064a\u0641 \u064a\u0645\u0643\u0646\u0646\u064a \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0645\u0639 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0627\u0644\u062e\u0648\u0627\u0626\u064a \u062a\u062d\u062a \u0627\u0644\u0636\u0645\u0627\u0646\u061f<\/strong><\/p>\n\n\n\n<p>\u0642\u0645 \u0628\u062a\u0648\u062b\u064a\u0642 \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0641\u0634\u0644 \u0639\u0644\u0649 \u0627\u0644\u0641\u0648\u0631: (1) \u0633\u062c\u0644 \u0625\u062c\u0645\u0627\u0644\u064a \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0646 \u0627\u0644\u0639\u062f\u0627\u062f (\u0625\u0630\u0627 \u0643\u0627\u0646 \u0645\u062b\u0628\u062a\u064b\u0627) \u0623\u0648 \u062a\u0642\u062f\u064a\u0631\u064b\u0627 \u0645\u0646 \u062a\u0627\u0631\u064a\u062e \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u062f\u0648\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629\u061b (2) \u0642\u0645 \u0628\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0625\u0630\u0627 \u0643\u0627\u0646 \u064a\u0645\u0643\u0646 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u064a\u0647\u0627 - \u062a\u0634\u064a\u0631 \u0627\u0644\u0642\u064a\u0645 &gt; 500 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631 \u0645\u0643\u0639\u0628 \u0625\u0644\u0649 \u062a\u0622\u0643\u0644 \u0645\u0641\u0631\u0637\u061b (3) \u0642\u0645 \u0628\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u062a\u0644\u0641 \u0627\u0644\u0645\u0631\u0626\u064a (\u0623\u0637\u0631\u0627\u0641 \u0645\u062d\u062a\u0631\u0642\u0629\u060c \u0639\u0648\u0627\u0632\u0644 \u0645\u062a\u0635\u062f\u0639\u0629\u060c \u0639\u0644\u0627\u0645\u0627\u062a \u062a\u062a\u0628\u0639)\u061b (4) \u0627\u062d\u062a\u0641\u0638 \u0628\u0627\u0644\u0648\u062d\u062f\u0629 \u0627\u0644\u0641\u0627\u0634\u0644\u0629 (\u0644\u0627 \u062a\u062a\u062e\u0644\u0635 \u0645\u0646\u0647\u0627 \u0642\u0628\u0644 \u0641\u062d\u0635 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629). \u0627\u062a\u0635\u0644 \u0628\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0641\u0646\u064a \u0644\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0641\u064a \u063a\u0636\u0648\u0646 48 \u0633\u0627\u0639\u0629 - \u062a\u062a\u0637\u0644\u0628 \u0645\u0639\u0638\u0645 \u0627\u0644\u0636\u0645\u0627\u0646\u0627\u062a \u0625\u062e\u0637\u0627\u0631\u064b\u0627 \u0641\u0648\u0631\u064a\u064b\u0627. \u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u062a\u0631\u0633\u0644 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0623\u0648\u0644 \u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0645\u064a\u062f\u0627\u0646\u064a\u064a\u0646 \u0644\u0641\u062d\u0635 \u0627\u0644\u0636\u0645\u0627\u0646 \u0641\u064a \u063a\u0636\u0648\u0646 \u0623\u0633\u0628\u0648\u0639 \u0648\u0627\u062d\u062f \u0648\u062a\u0648\u0641\u0631 \u0648\u062d\u062f\u0627\u062a \u0645\u0633\u062a\u0639\u0627\u0631\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629. \u0642\u062f \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u0648\u0646 \u0634\u062d\u0646 \u0627\u0644\u0648\u062d\u062f\u0629 \u0627\u0644\u0645\u0639\u0637\u0644\u0629 \u0625\u0644\u0649 \u0627\u0644\u0645\u0635\u0646\u0639 (\u0639\u0645\u0644\u064a\u0629 \u062a\u0633\u062a\u063a\u0631\u0642 \u0645\u0646 4 \u0625\u0644\u0649 8 \u0623\u0633\u0627\u0628\u064a\u0639)\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u0625\u0637\u0627\u0644\u0629 \u0641\u062a\u0631\u0629 \u0627\u0644\u062a\u0648\u0642\u0641 \u0639\u0646 \u0627\u0644\u0639\u0645\u0644 \u0645\u0627 \u0644\u0645 \u064a\u062a\u0645 \u0627\u0644\u0627\u062d\u062a\u0641\u0627\u0638 \u0628\u0645\u062e\u0632\u0648\u0646 \u0627\u062d\u062a\u064a\u0627\u0637\u064a.<\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Selecting a vacuum contactor manufacturer is not a commodity decision. Two contactors rated 12 kV, 400 A, AC-4 can differ by a factor of three in mechanical life, exhibit contact erosion rates varying 40%, and ship with documentation quality ranging from \u201ccomplete type-test certificates\u201d to \u201ctrust us, it works.\u201d These differences surface 18 months [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2388,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25,28],"tags":[],"class_list":["post-2386","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge","category-industry-news"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=2386"}],"version-history":[{"count":6,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2386\/revisions"}],"predecessor-version":[{"id":3851,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2386\/revisions\/3851"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/2388"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=2386"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=2386"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=2386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}