{"id":2537,"date":"2026-01-10T07:15:50","date_gmt":"2026-01-10T07:15:50","guid":{"rendered":"https:\/\/xbrele.com\/?p=2537"},"modified":"2026-04-07T13:16:04","modified_gmt":"2026-04-07T13:16:04","slug":"vcb-maintenance-checklist","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/vcb-maintenance-checklist\/","title":{"rendered":"\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640 VCB: \u0645\u0627 \u064a\u062c\u0628 \u0627\u0644\u0642\u064a\u0627\u0645 \u0628\u0647 \u0643\u0644 \u062b\u0644\u0627\u062b\u0629 \u0623\u0634\u0647\u0631\/\u0633\u0646\u0648\u064a\u0627\u064b (\u0646\u0645\u0648\u0630\u062c \u0627\u0644\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629)"},"content":{"rendered":"\ufeff\n<p>\u062a\u062a\u0639\u0637\u0644 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0628\u0637\u0631\u0642 \u064a\u0645\u0643\u0646 \u0627\u0644\u062a\u0646\u0628\u0624 \u0628\u0647\u0627. \u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0645\u0646 \u0637\u0627\u0642\u0629 \u0627\u0644\u0642\u0648\u0633\u060c \u0648\u0627\u0646\u062d\u0631\u0627\u0641 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0645\u0646 \u062a\u0622\u0643\u0644 \u0627\u0644\u0622\u0644\u064a\u0629\u060c \u0648\u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u0639\u0632\u0644 \u0645\u0646 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 - \u062a\u0639\u0644\u0646 \u0623\u0648\u0636\u0627\u0639 \u0627\u0644\u062a\u062f\u0647\u0648\u0631 \u0647\u0630\u0647 \u0639\u0646 \u0646\u0641\u0633\u0647\u0627 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0624\u0634\u0631\u0627\u062a \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0642\u064a\u0627\u0633 \u0642\u0628\u0644 \u0623\u0634\u0647\u0631 \u0645\u0646 \u062d\u062f\u0648\u062b \u0639\u0637\u0644 \u0643\u0627\u0631\u062b\u064a.<\/p>\n\n\n\n<p>\u0639\u0644\u0649 \u0639\u0643\u0633 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0642\u0648\u0645 \u0628\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0622\u0644\u0627\u0641 \u0627\u0644\u0645\u0631\u0627\u062a \u0633\u0646\u0648\u064a\u064b\u0627\u060c \u0641\u0625\u0646 \u0623\u062c\u0647\u0632\u0629 VCBs \u062a\u0642\u0627\u0637\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0645\u0646 \u062d\u064a\u0646 \u0644\u0622\u062e\u0631 \u0648\u0644\u0643\u0646 \u064a\u062c\u0628 \u0623\u0646 \u062a\u0639\u0645\u0644 \u0628\u062f\u0648\u0646 \u0623\u062e\u0637\u0627\u0621 \u0639\u0646\u062f \u0627\u0633\u062a\u062f\u0639\u0627\u0626\u0647\u0627. \u064a\u0624\u062f\u064a \u0641\u0634\u0644 \u0648\u0627\u062d\u062f \u0641\u064a \u0625\u0632\u0627\u0644\u0629 \u062f\u0627\u0626\u0631\u0629 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0642\u0635\u064a\u0631\u0629 \u0625\u0644\u0649 \u062d\u062f\u0648\u062b \u0634\u0644\u0627\u0644\u0627\u062a: \u062a\u0644\u0641 \u0627\u0644\u0645\u0639\u062f\u0627\u062a\u060c \u0648\u0648\u0642\u062a \u062a\u0639\u0637\u0644 \u0637\u0648\u064a\u0644\u060c \u0648\u062d\u0648\u0627\u062f\u062b \u062a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0633\u0644\u0627\u0645\u0629. \u064a\u0643\u0644\u0641 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 \u062c\u0647\u0627\u0632 VCB \u0627\u0644\u0630\u064a \u064a\u0632\u064a\u0644 \u0639\u0637\u0644 25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u0641\u064a 50 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631\u060c \u0648\u0627\u0644\u0622\u062e\u0631 \u0627\u0644\u0630\u064a \u064a\u0641\u0634\u0644 \u0641\u064a \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629 \u0639\u0634\u0631\u0627\u062a \u0623\u0648 \u0645\u0626\u0627\u062a \u0627\u0644\u0622\u0644\u0627\u0641 \u0645\u0646 \u0627\u0644\u062f\u0648\u0644\u0627\u0631\u0627\u062a.<\/p>\n\n\n\n<p>\u062a\u0643\u062a\u0634\u0641 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0644\u0641 \u0645\u0628\u0643\u0631\u064b\u0627. \u064a\u062d\u062f\u062f \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a \u0631\u0628\u0639 \u0627\u0644\u0633\u0646\u0648\u064a \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u0641\u0643\u0648\u0643\u0629 \u0642\u0628\u0644 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0641\u064a \u062a\u0644\u0641 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0648\u064a\u0643\u0634\u0641 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0627\u0644\u0633\u0646\u0648\u064a \u0639\u0646 \u062a\u0628\u0627\u0637\u0624 \u0633\u0631\u0639\u0629 \u0641\u062a\u062d 15% - \u0644\u064a\u0633 \u0639\u0637\u0644\u064b\u0627 \u0628\u0639\u062f\u060c \u0648\u0644\u0643\u0646\u0647 \u064a\u062a\u062c\u0647 \u0646\u062d\u0648 \u0639\u062a\u0628\u0629 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644. \u062a\u062d\u0648\u0644 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u0646\u0638\u0645\u0629 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0639\u0634\u0648\u0627\u0626\u064a\u0629 \u0625\u0644\u0649 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0645\u062e\u0637\u0637 \u0644\u0647\u0627 \u062e\u0644\u0627\u0644 \u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0645\u062c\u062f\u0648\u0644\u0629.<\/p>\n\n\n\n<p>\u062a\u0648\u0641\u0631 \u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0647\u0630\u0647 \u0645\u0647\u0627\u0645 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0641\u0635\u0644\u064a\u0629 \u0648\u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u062f\u0629\u060c \u0648\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644\u060c \u0648\u0642\u0648\u0627\u0644\u0628 \u0627\u0644\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0627\u0644\u062a\u064a \u064a\u062d\u062a\u0627\u062c \u0627\u0644\u0645\u0647\u0646\u062f\u0633\u0648\u0646 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u064a\u0647\u0627&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\">\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/a>&nbsp;\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0639\u0628\u0631 \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0648\u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u0635\u0646\u0641\u0629 12-40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640 VCB: \u062f\u0644\u064a\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0631\u0628\u0639 \u0627\u0644\u0633\u0646\u0648\u064a \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0633\u0646\u0648\u064a (\u0645\u0631\u0641\u0642 \u0646\u0645\u0648\u0630\u062c \u0645\u064a\u062f\u0627\u0646\u064a)\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/78lbXrzw85U?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-vcb-maintenance-differs-from-contactor-maintenance\">\u0644\u0645\u0627\u0630\u0627 \u062a\u062e\u062a\u0644\u0641 \u0635\u064a\u0627\u0646\u0629 VCB \u0639\u0646 \u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u0644\u0627\u0645\u0633 \u0639\u0646 \u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u0644\u0627\u0645\u0633<\/h2>\n\n\n\n<p>\u064a\u0633\u062a\u062e\u062f\u0645 \u0643\u0644 \u0645\u0646 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0642\u0648\u0627\u0637\u0639 \u062a\u0641\u0631\u064a\u063a\u060c \u0648\u0644\u0643\u0646 \u062a\u062e\u062a\u0644\u0641 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0647\u0645 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631.<\/p>\n\n\n\n<p><strong>\u0645\u0642\u0627\u0631\u0646\u0629 \u062f\u0648\u0631\u0629 \u0627\u0644\u0639\u0645\u0644:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th><th>\u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a<\/th><th>\u0645\u0648\u0635\u0644 \u0641\u0631\u0627\u063a\u064a<\/th><\/tr><\/thead><tbody><tr><td><strong>\u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/strong><\/td><td>\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062e\u0644\u0644<\/td><td>\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0623\u062d\u0645\u0627\u0644<\/td><\/tr><tr><td><strong>\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a\/\u0627\u0644\u0633\u0646\u0629<\/strong><\/td><td>5-20 (\u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0646\u0627\u062f\u0631\u0629)<\/td><td>5,000-5,000 (\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631)<\/td><\/tr><tr><td><strong>\u0627\u0644\u0645\u0642\u0637\u0648\u0639\u0629 \u0627\u0644\u062d\u0627\u0644\u064a\u0629<\/strong><\/td><td>10-40\u00d740 \u00d7 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (\u0645\u0627\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u0649)<\/td><td>1-8\u00d7 \u0645\u0635\u0646\u0641\u0629 (\u062a\u062f\u0641\u0642\/\u0639\u0627\u062f\u064a)<\/td><\/tr><tr><td><strong>\u0637\u0627\u0642\u0629 \u0627\u0644\u0642\u0648\u0633 \u0644\u0643\u0644 \u0639\u0645\u0644\u064a\u0629<\/strong><\/td><td>\u0639\u0627\u0644\u064a\u0629 \u062c\u062f\u064b\u0627 (\u0623\u0639\u0637\u0627\u0644 \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 kA)<\/td><td>\u0645\u0639\u062a\u062f\u0644\u0629 (\u062a\u064a\u0627\u0631\u0627\u062a \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062d\u0645\u0644)<\/td><\/tr><tr><td><strong>\u0637\u0627\u0642\u0629 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u062a\u0631\u0627\u0643\u0645\u064a<\/strong><\/td><td>\u0645\u0639\u062a\u062f\u0644 (\u0639\u0645\u0644\u064a\u0627\u062a \u0642\u0644\u064a\u0644\u0629 \u00d7 \u0637\u0627\u0642\u0629 \u0639\u0627\u0644\u064a\u0629)<\/td><td>\u0639\u0627\u0644\u064a\u0629 (\u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u00d7 \u0637\u0627\u0642\u0629 \u0645\u0639\u062a\u062f\u0644\u0629)<\/td><\/tr><tr><td><strong>\u0639\u0648\u0627\u0642\u0628 \u0627\u0644\u0641\u0634\u0644<\/strong><\/td><td>\u0643\u0627\u0631\u062b\u064a\u0629 (\u062a\u062f\u0645\u064a\u0631 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629)<\/td><td>\u0645\u062a\u0648\u0633\u0637 (\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0639\u0645\u0644\u064a\u0629)<\/td><\/tr><tr><td><strong>\u0623\u0648\u0644\u0648\u064a\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/strong><\/td><td>\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/td><td>\u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u062a\u0624\u0643\u062f \u0635\u064a\u0627\u0646\u0629 \u0628\u0646\u0643 \u0631\u0623\u0633 \u0627\u0644\u0645\u0627\u0644 \u0627\u0644\u0645\u062a\u062f\u0627\u0648\u0644 \u0639\u0644\u0649&nbsp;<strong>\u0627\u0644\u0627\u0633\u062a\u0639\u062f\u0627\u062f<\/strong>-\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0642\u0627\u0637\u0639 \u0633\u064a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d \u0623\u062b\u0646\u0627\u0621 \u062d\u062f\u062b \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0646\u0627\u062f\u0631. \u062a\u0631\u0643\u0632 \u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0639\u0644\u0649&nbsp;<strong>\u0627\u0644\u062a\u062d\u0645\u0644<\/strong>-\u062a\u062a\u0628\u0639 \u0627\u0644\u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0631\u0627\u0643\u0645\u064a \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631.<\/p>\n\n\n\n<p>\u062a\u062e\u062a\u0644\u0641 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0623\u064a\u0636\u0627\u064b \u062d\u0633\u0628&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/vcb-lubrication-overhaul-guide\/\">\u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a\u0629 \u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0648\u0627\u0644\u0625\u0635\u0644\u0627\u062d \u0627\u0644\u0634\u0627\u0645\u0644 \u0644\u0628\u0646\u0643 VCB<\/a>&nbsp;\u0648\u0643\u0630\u0644\u0643 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0648\u0641\u0626\u0629 \u0627\u0644\u062c\u0647\u062f \u0648\u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642. \u0642\u062f \u062a\u062a\u0637\u0644\u0628 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629 \u062a\u0646\u0638\u064a\u0641\u064b\u0627 \u0623\u0643\u062b\u0631 \u062a\u0648\u0627\u062a\u0631\u064b\u0627 \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0645\u062a\u0631\u0628\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0648\u0627\u062c\u0647 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 \u062a\u062d\u062f\u064a\u0627\u062a \u062a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0639\u0648\u0627\u0645\u0644 \u0627\u0644\u062c\u0648\u064a\u0629 \u0648\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629.<\/p>\n\n\n\n<p>\u0643\u0644\u0627\u0647\u0645\u0627 \u064a\u062a\u0637\u0644\u0628 \u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0641\u062d\u0648\u0635\u0627\u062a \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u0644\u0643\u0646 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u0631\u062d\u064a\u0644 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a\u0629 \u062a\u0636\u064a\u0641 \u062a\u0631\u0643\u064a\u0632\u064b\u0627 \u062d\u0627\u0633\u0645\u064b\u0627 \u0639\u0644\u0649 \u0627\u0644\u062a\u0648\u0642\u064a\u062a\/\u0627\u0644\u0633\u0641\u0631 (\u062a\u0639\u062a\u0645\u062f \u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629 \u0639\u0644\u0649 \u0633\u0631\u0639\u0629 \u0627\u0644\u0641\u062a\u062d) \u0648\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 (\u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0637\u0627\u0628\u0642 \u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u0645\u0631\u062d\u0644 \u0645\u0639 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0641\u0639\u0644\u064a \u0644\u0644\u0642\u0627\u0637\u0639).<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-interval-framework\">\u0625\u0637\u0627\u0631 \u0639\u0645\u0644 \u0641\u062a\u0631\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/h2>\n\n\n\n<p>\u0627\u062c\u0645\u0639 \u0628\u064a\u0646 \u0627\u0644\u0645\u0634\u063a\u0651\u0644\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u0648\u0642\u062a \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u062d\u0627\u0644\u0629 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u062a\u063a\u0637\u064a\u0629 \u0634\u0627\u0645\u0644\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"quarterly-maintenance-every-3-months\">\u0635\u064a\u0627\u0646\u0629 \u0631\u0628\u0639 \u0633\u0646\u0648\u064a\u0629 (\u0643\u0644 3 \u0623\u0634\u0647\u0631)<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0637\u0627\u0642<\/strong>: \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a \u0648\u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0648\u0638\u064a\u0641\u064a\u0629 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<br><strong>\u0627\u0644\u0645\u062f\u0629<\/strong>: 30-60 \u062f\u0642\u064a\u0642\u0629 \u0644\u0643\u0644 \u0642\u0627\u0637\u0639<br><strong>\u064a\u0645\u0643\u0646 \u0625\u062c\u0631\u0627\u0624\u0647\u0627<\/strong>: \u0623\u062b\u0646\u0627\u0621 \u062c\u0648\u0644\u0627\u062a \u0627\u0644\u0645\u0646\u0634\u0623\u0629\u060c \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0627\u0644\u062a\u0623\u062b\u064a\u0631 \u0639\u0644\u0649 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0647\u0627\u0645<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a (\u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 \u0648\u0627\u0644\u0646\u0638\u0627\u0641\u0629)<\/li>\n\n\n\n<li>\u0641\u062d\u0635 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a (\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0639\u062b\u0631\/\u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u064a\u062f\u0648\u064a \u0623\u0648 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 (\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629)<\/li>\n\n\n\n<li>\u0641\u062d\u0635 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u0641\u0643\u0648\u0643\u0629 (\u0641\u062d\u0635 \u0639\u0632\u0645 \u0627\u0644\u062f\u0648\u0631\u0627\u0646 \u0639\u0644\u0649 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631 (\u0628\u0631\u0627\u063a\u064a) \u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u064a\u0647\u0627)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0628\u064a\u0626\u064a (\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062a\u0644\u0648\u062b)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"annual-maintenance-every-12-months\">\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0633\u0646\u0648\u064a\u0629 (\u0643\u0644 12 \u0634\u0647\u0631\u0627\u064b)<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0637\u0627\u0642<\/strong>: \u0627\u062e\u062a\u0628\u0627\u0631 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0645\u0641\u0635\u0644<br><strong>\u0627\u0644\u0645\u062f\u0629<\/strong>:: 2-4 \u0633\u0627\u0639\u0627\u062a \u0644\u0643\u0644 \u0642\u0627\u0637\u0639<br><strong>\u064a\u062a\u0637\u0644\u0628<\/strong>: \u0639\u0632\u0644 \u0627\u0644\u0642\u0648\u0627\u0637\u0639\u060c \u0648\u0645\u0639\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062a\u062e\u0635\u0635\u0629\u060c \u0648\u0645\u0648\u0638\u0641\u064a\u0646 \u0645\u062f\u0631\u0628\u064a\u0646<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0647\u0627\u0645<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 (\u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u0642\u0637\u0627\u0628)<\/li>\n\n\n\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 (\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a\u060c \u0648\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0648\u0627\u0644\u0625\u0637\u0627\u0631)<\/li>\n\n\n\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0648\u0627\u0644\u0633\u0641\u0631 (\u0633\u0631\u0639\u0629 \u0627\u0644\u0641\u062a\u062d\/\u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0648\u0633\u0631\u0639\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633)<\/li>\n\n\n\n<li>\u0641\u062d\u0635 \u0622\u0644\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 (\u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0648\u0627\u0644\u062a\u0622\u0643\u0644 \u0648\u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629)<\/li>\n\n\n\n<li>\u0641\u062d\u0635 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (\u062a\u062d\u0645\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0623\u0648 \u0627\u0644\u0637\u0631\u0642 \u0627\u0644\u0628\u062f\u064a\u0644\u0629)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062f\u0627\u0631\u0629 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0648\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u0639\u0634\u064a\u0642<\/li>\n\n\n\n<li>\u0645\u0631\u0627\u062c\u0639\u0629 \u062a\u0646\u0633\u064a\u0642 \u062a\u0631\u062d\u064a\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"biennialextended-maintenance-every-2\u20135-years\">\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0643\u0644 \u0633\u0646\u062a\u064a\u0646\/\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u0645\u062a\u062f\u0629 (\u0643\u0644 2-5 \u0633\u0646\u0648\u0627\u062a)<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0637\u0627\u0642<\/strong>: \u062a\u0642\u064a\u064a\u0645 \u0634\u0627\u0645\u0644\u060c \u0648\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u064a\u062a\u0632\u0627\u0645\u0646 \u0645\u0639 \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<br><strong>\u0627\u0644\u0645\u062f\u0629<\/strong>: \u064a\u0648\u0645 \u0643\u0627\u0645\u0644 \u0644\u0643\u0644 \u0642\u0627\u0637\u0639 (\u0645\u0639 \u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0627\u0644\u0644\u0648\u062d\u0629)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0647\u0627\u0645<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649:<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0641\u062a\u064a\u0634 \u0627\u0644\u062f\u0627\u062e\u0644\u064a (\u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u064a\u0633\u0645\u062d \u0628\u0627\u0644\u0648\u0635\u0648\u0644 \u0627\u0644\u0622\u0645\u0646)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u062a\u062d\u062a \u0627\u0644\u062d\u0645\u0644 (\u0625\u0630\u0627 \u0643\u0627\u0646 \u0645\u0646 \u0627\u0644\u0645\u0645\u0643\u0646 \u062a\u0646\u0634\u064a\u0637\u0647 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631)<\/li>\n\n\n\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a (\u0627\u0644\u062a\u0634\u062e\u064a\u0635 \u0627\u0644\u0645\u062a\u0642\u062f\u0645)<\/li>\n\n\n\n<li>\u0625\u0635\u0644\u0627\u062d \u0643\u0627\u0645\u0644 \u0644\u0622\u0644\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 (\u0627\u0644\u062a\u0641\u0643\u064a\u0643 \u0648\u0627\u0644\u062a\u0646\u0638\u064a\u0641 \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0623\u062c\u0632\u0627\u0621)<\/li>\n\n\n\n<li>\u062a\u062d\u062f\u064a\u062b\u0627\u062a \u0627\u0644\u0628\u0631\u0627\u0645\u062c \u0627\u0644\u062b\u0627\u0628\u062a\u0629 \u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0629<\/li>\n\n\n\n<li>\u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0645\u0645\u0627\u062b\u0644\u0629 \u0641\u064a \u0627\u0644\u0623\u0633\u0637\u0648\u0644 (\u0627\u062a\u062c\u0627\u0647 \u0635\u062d\u0629 \u0627\u0644\u0623\u0633\u0637\u0648\u0644)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operation-based-triggers\">\u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a<\/h3>\n\n\n\n<p>\u0628\u063a\u0636 \u0627\u0644\u0646\u0638\u0631 \u0639\u0646 \u0627\u0644\u0648\u0642\u062a\u060c \u0642\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0643\u0627\u0645\u0644 \u0628\u0639\u062f \u0630\u0644\u0643:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0643\u0644 2,000 \u0639\u0645\u0644\u064a\u0629 \u062c\u0631\u0627\u062d\u064a\u0629<\/strong>&nbsp;\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 (\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0645\u0648\u0644\u062f\u0627\u062a\u060c \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u062d\u0648\u064a\u0644)<\/li>\n\n\n\n<li><strong>\u0628\u0639\u062f \u062d\u062f\u0648\u062b \u0623\u064a \u0627\u0646\u0642\u0637\u0627\u0639 \u0641\u064a \u0627\u0644\u0623\u0639\u0637\u0627\u0644<\/strong>&nbsp;&gt;50% \u0645\u0646 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/li>\n\n\n\n<li><strong>\u0628\u0639\u062f \u0623\u064a \u0639\u0645\u0644\u064a\u0629 \u0641\u0627\u0634\u0644\u0629<\/strong>&nbsp;(\u0639\u062f\u0645 \u0627\u0644\u062a\u0639\u062b\u0631\u060c \u0639\u062f\u0645 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0639\u062f\u0645 \u0627\u0643\u062a\u0645\u0627\u0644 \u0627\u0644\u0633\u0641\u0631)<\/li>\n<\/ul>\n\n\n\n<p>\u062a\u062a\u0628\u0639 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0639\u0628\u0631:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0639\u062f\u0627\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a (\u0641\u064a \u062d\u0627\u0644\u0629 \u062a\u0631\u0643\u064a\u0628\u0647)<\/li>\n\n\n\n<li>\u0633\u062c\u0644\u0627\u062a \u0623\u062d\u062f\u0627\u062b \u0648\u062d\u062f\u0629 \u0627\u0644\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0629<\/li>\n\n\n\n<li>\u0633\u062c\u0644\u0627\u062a \u062a\u0634\u063a\u064a\u0644 SCADA<\/li>\n\n\n\n<li>\u0623\u0648\u0631\u0627\u0642 \u0627\u0644\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u064a\u062f\u0648\u064a\u0629 (\u0644\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0642\u062f\u064a\u0645\u0629 \u0628\u062f\u0648\u0646 \u0639\u062f\u0627\u062f\u0627\u062a)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"condition-based-triggers\">\u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u062d\u0627\u0644\u0629<\/h3>\n\n\n\n<p>\u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u0641\u0648\u0631\u064a \u063a\u064a\u0631 \u0645\u062c\u062f\u0648\u0644 \u0639\u0646\u062f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0636\u0648\u0636\u0627\u0621 \u063a\u064a\u0631 \u0645\u0639\u062a\u0627\u062f\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 (\u0623\u0635\u0648\u0627\u062a \u0637\u062d\u0646\u060c \u0623\u0635\u0648\u0627\u062a \u0627\u0635\u0637\u062f\u0627\u0645)<\/li>\n\n\n\n<li>\u0644\u0648\u062d\u0638 \u062a\u0645\u062f\u064a\u062f \u0648\u0642\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0645\u062a\u062f<\/li>\n\n\n\n<li>\u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621 \u0627\u0644\u0645\u0631\u0626\u064a \u0623\u0648 \u0627\u0644\u0648\u0645\u064a\u0636 \u0627\u0644\u0648\u0627\u0645\u0636<\/li>\n\n\n\n<li>\u0639\u0637\u0644 \u0641\u064a \u0645\u0644\u0641 \u0627\u0644\u062a\u0639\u062b\u0631 \u0623\u0648 \u0639\u0637\u0644 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645<\/li>\n\n\n\n<li>\u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0643\u062a\u0634\u0641\u0629 (\u062c\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a)<\/li>\n\n\n\n<li>\u0631\u062d\u0644\u0629 \u0645\u0632\u0639\u062c\u0629 \u0644\u0645\u0631\u062d\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 (\u0642\u062f \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0627\u0646\u062d\u0631\u0627\u0641 \u062a\u0648\u0642\u064a\u062a VCB)<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix.webp\" alt=\"\u0645\u0635\u0641\u0648\u0641\u0629 \u0642\u0631\u0627\u0631\u0627\u062a \u0627\u0644\u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0641\u0627\u0635\u0644\u0629 \u0628\u064a\u0646 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u064a \u062a\u064f\u0638\u0647\u0631 \u0627\u0644\u0645\u0647\u0627\u0645 \u0627\u0644\u0641\u0635\u0644\u064a\u0629 \u0648\u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0648\u0645\u0647\u0627\u0645 \u0627\u0644\u0633\u0646\u062a\u064a\u0646 \u0627\u0644\u062a\u064a \u064a\u062a\u0645 \u062a\u0639\u064a\u064a\u0646\u0647\u0627 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0627\u0644\u0642\u0627\u0626\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0648\u0642\u062a \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u062d\u0627\u0644\u0629 \u0644\u0635\u064a\u0627\u0646\u0629 \u0628\u0646\u0643 \u0631\u0623\u0633 \u0627\u0644\u0645\u0627\u0644 \u0627\u0644\u0645\u062a\u062f\u0627\u0648\u0644\" class=\"wp-image-2539\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0627\u0644\u0634\u0643\u0644 1**: \u064a\u062c\u0645\u0639 \u0625\u0637\u0627\u0631 \u0627\u0644\u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0632\u0645\u0646\u064a\u0629 \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0628\u064a\u0646 \u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u0648\u0642\u062a (\u0631\u0628\u0639 \u0633\u0646\u0648\u064a\u0629\/\u0633\u0646\u0648\u064a\u0629\/\u0643\u0644 \u0633\u0646\u062a\u064a\u0646)\u060c \u0648\u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 (\u0643\u0644 2000 \u0639\u0645\u0644\u064a\u0629\u060c \u0628\u0639\u062f \u0648\u0642\u0648\u0639 \u062e\u0637\u0623)\u060c \u0648\u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u062d\u0627\u0644\u0629 (\u0627\u0644\u0636\u0648\u0636\u0627\u0621 \u063a\u064a\u0631 \u0627\u0644\u0639\u0627\u062f\u064a\u0629\u060c \u0648\u0627\u0646\u062d\u0631\u0627\u0641 \u0627\u0644\u062a\u0648\u0642\u064a\u062a) \u0644\u0636\u0645\u0627\u0646 \u0645\u0631\u0627\u0642\u0628\u0629 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u0631\u0643\u0628\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0639\u064a\u0627\u0631 \u0627\u0644\u062b\u0642\u064a\u0644 \u0628\u0634\u0643\u0644 \u0634\u0627\u0645\u0644.\n<br><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quarterly-maintenance-detailed-procedure\">\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0641\u0635\u0644\u064a\u0629: \u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a\u0629<\/h2>\n\n\n\n<p>\u062a\u0639\u0645\u0644 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0641\u0635\u0644\u064a\u0629 \u0639\u0644\u0649 \u0627\u0643\u062a\u0634\u0627\u0641 \u0627\u0644\u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0645\u062a\u0637\u0648\u0631\u0629 \u0642\u0628\u0644 \u0623\u0646 \u062a\u062a\u0637\u0644\u0628 \u0625\u0635\u0644\u0627\u062d\u0627\u062a \u0637\u0627\u0631\u0626\u0629.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-visual-inspection\">1. \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a<\/h3>\n\n\n\n<p><strong>\u062a\u062d\u0642\u0642 \u0645\u0646:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u0646\u0638\u0627\u0641\u0629 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629<\/strong>: \u064a\u0624\u062f\u064a \u062a\u0631\u0627\u0643\u0645 \u0627\u0644\u063a\u0628\u0627\u0631 \u0639\u0644\u0649 \u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0625\u0644\u0649 \u0625\u0646\u0634\u0627\u0621 \u0645\u0633\u0627\u0631\u0627\u062a \u062a\u062a\u0628\u0639<\/li>\n\n\n\n<li><strong>\u062a\u0633\u0631\u0628 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/strong>: \u0627\u0644\u062a\u0643\u062b\u0641 \u0648\u0628\u0642\u0639 \u0627\u0644\u0645\u0627\u0621 (\u062e\u0627\u0635\u0629 \u0641\u064a \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629\/\u0627\u0644\u0631\u0637\u0628\u0629)<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0623\u0636\u0631\u0627\u0631 \u0627\u0644\u0645\u0627\u062f\u064a\u0629<\/strong>: \u062a\u0634\u0642\u0642\u0627\u062a \u0641\u064a \u0627\u0644\u0639\u0648\u0627\u0632\u0644\u060c \u0648\u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u062b\u0646\u064a\u0629 \u0648\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u0635\u062f\u0645<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0622\u0643\u0644<\/strong>: \u062e\u0627\u0635\u0629 \u0639\u0644\u0649 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631 \u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631 \u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631 \u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631 \u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631<\/li>\n\n\n\n<li><strong>\u0646\u0634\u0627\u0637 \u0627\u0644\u062d\u0634\u0631\u0627\u062a\/\u0627\u0644\u0642\u0648\u0627\u0631\u0636<\/strong>: \u0627\u0644\u0623\u0639\u0634\u0627\u0634 \u0648\u0627\u0644\u0641\u0636\u0644\u0627\u062a \u0648\u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0627\u0644\u0645\u0645\u0636\u0648\u063a\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0647\u0648\u064a\u0629<\/strong>: \u0641\u062a\u062d\u0627\u062a \u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u063a\u064a\u0631 \u0645\u0633\u062f\u0648\u062f\u0629\u060c \u0627\u0644\u0645\u0631\u0627\u0648\u062d \u062a\u0639\u0645\u0644 (\u0625\u0646 \u0648\u062c\u062f\u062a)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u062a\u0628\u0639 \u0645\u0631\u0626\u064a (\u0645\u0633\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0631\u0628\u0648\u0646 \u0639\u0644\u0649 \u0627\u0644\u0639\u0648\u0627\u0632\u0644)<\/li>\n\n\n\n<li>\u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0634\u0642\u0648\u0642 &gt; 1 \u0645\u0645 \u0641\u064a \u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a\u0629<\/li>\n\n\n\n<li>\u0644\u0627 \u064a\u0648\u062c\u062f \u062f\u0644\u064a\u0644 \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 (\u062a\u063a\u064a\u0631 \u0627\u0644\u0644\u0648\u0646\u060c \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0630\u0627\u0626\u0628\u0629)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u0635\u062d\u064a\u062d\u064a\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0646\u0638\u064a\u0641 \u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0628\u0643\u062d\u0648\u0644 \u0627\u0644\u0623\u064a\u0632\u0648\u0628\u0631\u0648\u0628\u064a\u0644 \u0648\u0642\u0637\u0639\u0629 \u0642\u0645\u0627\u0634 \u062e\u0627\u0644\u064a\u0629 \u0645\u0646 \u0627\u0644\u0648\u0628\u0631<\/li>\n\n\n\n<li>\u0633\u062f \u0627\u0644\u062b\u0642\u0648\u0628 \u0641\u064a \u0627\u0644\u062e\u0632\u0627\u0646\u0629 \u0644\u0645\u0646\u0639 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629\/\u0627\u0644\u0622\u0641\u0627\u062a<\/li>\n\n\n\n<li>\u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0627\u0644\u0645\u062a\u0634\u0642\u0642\u0629 \u0642\u0628\u0644 \u0627\u0644\u0639\u0648\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u062e\u062f\u0645\u0629<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-mechanical-operation-test\">2. \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u0639\u0632\u0648\u0644 \u0648\u0645\u0648\u0633\u0648\u0645 \u0628\u0639\u0644\u0627\u0645\u0629<\/li>\n\n\n\n<li>\u0622\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0634\u062d\u0646 (\u0645\u062d\u0631\u0643 \u0627\u0644\u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u064a \u0623\u0648 \u0627\u0644\u0645\u0636\u062e\u0629 \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a\u0629)<\/li>\n\n\n\n<li>\u0625\u062c\u0631\u0627\u0621 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u064a\u062f\u0648\u064a \u0623\u0648 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/li>\n\n\n\n<li>\u0644\u0627\u062d\u0638:\n<ul class=\"wp-block-list\">\n<li>\u062d\u0631\u0643\u0629 \u0633\u0644\u0633\u0629 \u0628\u062f\u0648\u0646 \u062a\u0631\u062f\u062f \u0623\u0648 \u0631\u0628\u0637<\/li>\n\n\n\n<li>\u0642\u0641\u0644 \u0625\u064a\u062c\u0627\u0628\u064a \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/li>\n\n\n\n<li>\u064a\u062a\u0648\u0642\u0641 \u0645\u062d\u0631\u0643 \u0627\u0644\u0634\u062d\u0646 \u062a\u0644\u0642\u0627\u0626\u064a\u0627\u064b \u0639\u0646\u062f \u0627\u0644\u0634\u062d\u0646 \u0627\u0644\u0643\u0627\u0645\u0644<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u0625\u062c\u0631\u0627\u0621 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0631\u062d\u0644\u0629<\/li>\n\n\n\n<li>\u0644\u0627\u062d\u0638:\n<ul class=\"wp-block-list\">\n<li>\u0627\u0633\u062a\u062c\u0627\u0628\u0629 \u0633\u0631\u064a\u0639\u0629 (\u0623\u0642\u0644 \u0645\u0646 100 \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629 \u0645\u0646 \u0625\u0634\u0627\u0631\u0629 \u0627\u0644\u062a\u0639\u062b\u0631 \u0625\u0644\u0649 \u0628\u062f\u0621 \u0641\u0635\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633)<\/li>\n\n\n\n<li>\u0644\u0627 \u064a\u0648\u062c\u062f \u0627\u0631\u062a\u062f\u0627\u062f \u062a\u0644\u0627\u0645\u0633 \u0645\u0633\u0645\u0648\u0639<\/li>\n\n\n\n<li>\u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0625\u064a\u062c\u0627\u0628\u064a \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u0641\u062a\u062d<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0627\u0644\u0642\u0628\u0648\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0639\u0645\u0644 \u0627\u0644\u0622\u0644\u064a\u0629 \u0628\u0633\u0644\u0627\u0633\u0629 \u062e\u0644\u0627\u0644 \u0634\u0648\u0637 \u0643\u0627\u0645\u0644<\/li>\n\n\n\n<li>\u062a\u0639\u0634\u064a\u0642 \u0627\u0644\u0645\u0632\u0627\u0644\u062c \u0628\u0634\u0643\u0644 \u0625\u064a\u062c\u0627\u0628\u064a (\u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u0639\u0634\u064a\u0642 \u0637\u0631\u064a \u0623\u0648 \u063a\u0627\u0645\u0636)<\/li>\n\n\n\n<li>\u064a\u0643\u062a\u0645\u0644 \u0627\u0644\u0634\u062d\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0645\u062d\u062f\u062f (\u0639\u0627\u062f\u0629\u064b \u0645\u0646 10 \u0625\u0644\u0649 30 \u062b\u0627\u0646\u064a\u0629)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0636\u0631\u0648\u0631\u0629 \u0625\u062c\u0631\u0627\u0621 \u0641\u062d\u0635 \u062a\u0641\u0635\u064a\u0644\u064a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062d\u0631\u0643\u0629 \u0628\u0637\u064a\u0626\u0629 \u0623\u0648 \u063a\u064a\u0631 \u0645\u0646\u062a\u0638\u0645\u0629 \u2192 \u0645\u0634\u0643\u0644\u0629 \u062a\u0634\u062d\u064a\u0645\u060c \u062a\u0622\u0643\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/li>\n\n\n\n<li>\u0639\u062f\u0645 \u0627\u0646\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u0632\u0644\u0627\u062c \u2192 \u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0632\u0644\u0627\u062c\u060c \u062a\u0622\u0643\u0644 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u060c \u0627\u062e\u062a\u0644\u0627\u0644 \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629<\/li>\n\n\n\n<li>\u0645\u062d\u0631\u0643 \u0627\u0644\u0634\u062d\u0646 \u064a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0645\u0633\u062a\u0645\u0631 \u2192 \u0641\u0634\u0644 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062d\u062f\u060c \u0627\u0644\u0631\u0628\u0637 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-control-circuit-verification\">3. \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645<\/h3>\n\n\n\n<p><strong>\u0642\u064a\u0627\u0633 \u0627\u0644\u062c\u0647\u062f<\/strong>:<\/p>\n\n\n\n<p>\u0642\u064a\u0627\u0633 \u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 \u0639\u0646\u062f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0623\u0637\u0631\u0627\u0641 \u0645\u0644\u0641 \u0627\u0644\u062a\u0639\u062b\u0631 \u0623\u062b\u0646\u0627\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0631\u062d\u0644\u0629<\/li>\n\n\n\n<li>\u0625\u063a\u0644\u0627\u0642 \u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0645\u0644\u0641 \u0623\u062b\u0646\u0627\u0621 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/li>\n\n\n\n<li>\u0623\u0637\u0631\u0627\u0641 \u0625\u0645\u062f\u0627\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u0628\u0648\u0644<\/strong>:: 85-110% 85-110% \u0644\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c 110-138 \u0641\u0648\u0644\u062a \u0644\u0646\u0638\u0627\u0645 125 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 (&lt;85%)<\/strong>: \u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0627\u0646\u062e\u0641\u0627\u0636 \u062c\u0647\u062f \u0627\u0644\u0623\u0633\u0644\u0627\u0643\u060c \u0648\u0636\u0639\u0641 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629\u060c \u0648\u062a\u0639\u0637\u0644 \u0627\u0644\u0634\u0627\u062d\u0646<br><strong>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a (&gt;110%)<\/strong>: \u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0639\u0637\u0644 \u0641\u064a \u0627\u0644\u0634\u0627\u062d\u0646 \u0648\u0627\u062d\u062a\u0645\u0627\u0644 \u062a\u0644\u0641 \u0627\u0644\u0645\u0644\u0641<\/p>\n\n\n\n<p><strong>\u0641\u062d\u0635 \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0627\u0644\u0625\u0636\u0627\u0641\u064a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u062f\u0645 \u0625\u063a\u0644\u0627\u0642 \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644 NO \u0639\u0646\u062f \u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0642\u0627\u0637\u0639<\/li>\n\n\n\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644 NC \u0645\u0641\u062a\u0648\u062d\u0629 \u0639\u0646\u062f \u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0642\u0627\u0637\u0639<\/li>\n\n\n\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0648\u062c\u0648\u062f \u0627\u0646\u062a\u0642\u0627\u0644\u0627\u062a \u0646\u0638\u064a\u0641\u0629 (\u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u0644\u0627\u0645\u0633 \u0645\u062a\u0642\u0637\u0639)<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u0645\u0644 \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0639\u0634\u064a\u0642 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d (\u0645\u0646\u0639 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0622\u0645\u0646\u0629)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-connection-torque-check\">4. \u0641\u062d\u0635 \u0639\u0632\u0645 \u062f\u0648\u0631\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0631\u0648\u0627\u0628\u0637 \u0627\u0644\u062d\u0631\u062c\u0629<\/strong>&nbsp;(\u0627\u0644\u062a\u062d\u0642\u0642 \u0633\u0646\u0648\u064a\u064b\u0627\u060c \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0627\u0644\u0641\u0648\u0631\u064a \u0643\u0644 \u062b\u0644\u0627\u062b\u0629 \u0623\u0634\u0647\u0631):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0639\u0645\u0648\u062f \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u0628\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0642\u0648\u0627\u0637\u0639<\/li>\n\n\n\n<li>\u0623\u0637\u0631\u0627\u0641 \u062a\u0648\u0635\u064a\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629<\/li>\n\n\n\n<li>\u0645\u0633\u0627\u0645\u064a\u0631 \u0631\u0628\u0637 \u0627\u0644\u0622\u0644\u064a\u0629<\/li>\n\n\n\n<li>\u0645\u0633\u0627\u0645\u064a\u0631 \u062a\u062b\u0628\u064a\u062a \u0627\u0644\u0644\u0648\u062d\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0633\u062a\u062e\u062f\u0645 \u0645\u0641\u062a\u0627\u062d \u0639\u0632\u0645 \u0627\u0644\u062f\u0648\u0631\u0627\u0646 \u0627\u0644\u0645\u0639\u0627\u064a\u0631<\/strong>&nbsp;\u062d\u0633\u0628 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 (\u0639\u0627\u062f\u0629\u064b):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u0633\u0627\u0645\u064a\u0631 M10: 45-55 \u0646\u064a\u0648\u062a\u0646\u22c5\u0645<\/li>\n\n\n\n<li>\u0645\u0633\u0627\u0645\u064a\u0631 M12: 70-85 \u0646\u064a\u0648\u062a\u0646\u22c5\u0645<\/li>\n\n\n\n<li>\u0648\u0635\u0644\u0627\u062a \u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629: 100-200 \u0646\u064a\u0648\u062a\u0646\u22c5\u0645\u062a\u0631 (\u062a\u062e\u062a\u0644\u0641 \u062d\u0633\u0628 \u0627\u0644\u062a\u0635\u0645\u064a\u0645)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0645\u0641\u0643\u0648\u0643\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u063a\u064a\u0631 \u0627\u0644\u0644\u0648\u0646 \u062d\u0648\u0644 \u0627\u0644\u0628\u0631\u063a\u064a<\/li>\n\n\n\n<li>\u0641\u062c\u0648\u0629 \u0645\u0631\u0626\u064a\u0629 \u0628\u064a\u0646 \u0627\u0644\u0623\u0633\u0637\u062d<\/li>\n\n\n\n<li>\u0642\u064a\u0645\u0629 \u0639\u0632\u0645 \u062f\u0648\u0631\u0627\u0646 \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u062d\u062f\u062f<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-environmental-documentation\">5. \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0627\u0644\u0628\u064a\u0626\u064a<\/h3>\n\n\n\n<p>\u0633\u062c\u0644 \u0644\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629<\/strong>&nbsp;\u0627\u0644\u0644\u0648\u062d\u0629 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0646\u0633\u0628\u064a\u0629<\/strong><\/li>\n\n\n\n<li><strong>\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062a\u0644\u0648\u062b<\/strong>&nbsp;(\u0646\u0638\u064a\u0641 \/ \u063a\u0628\u0627\u0631 \u062e\u0641\u064a\u0641 \/ \u062a\u0644\u0648\u062b \u0634\u062f\u064a\u062f)<\/li>\n\n\n\n<li><strong>\u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u0647\u0648\u064a\u0629<\/strong>&nbsp;(\u0643\u0627\u0641\u064a\u0629\/\u0645\u0642\u064a\u062f\u0629)<\/li>\n<\/ul>\n\n\n\n<p>\u064a\u0624\u062f\u064a \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 (&gt; 40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u062b\u0627\u0628\u062a\u0629) \u0623\u0648 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 (&gt; 851 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0631\u0637\u0648\u0628\u0629 \u0646\u0633\u0628\u064a\u0629) \u0625\u0644\u0649 \u062a\u0633\u0631\u064a\u0639 \u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u0639\u0632\u0644 - \u0642\u062f \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0623\u0645\u0631 \u0625\u062c\u0631\u0627\u0621 \u062a\u062d\u0633\u064a\u0646\u0627\u062a \u0641\u064a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0628\u064a\u0626\u064a \u0623\u0648 \u062a\u062e\u0641\u064a\u0641\u0647.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"annual-maintenance-detailed-testing\">\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0633\u0646\u0648\u064a\u0629: \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a<\/h2>\n\n\n\n<p>\u062a\u062a\u062d\u0642\u0642 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0645\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0639\u0627\u064a\u064a\u0631 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0642\u064a\u0627\u0633.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-contact-resistance-measurement\">1. \u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u063a\u0631\u0636<\/strong>: \u0627\u0644\u0643\u0634\u0641 \u0639\u0646 \u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u060c \u0648\u0627\u0644\u062a\u0644\u0648\u062b\u060c \u0648\u0627\u062e\u062a\u0644\u0627\u0644 \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629 \u0642\u0628\u0644 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0641\u064a \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0623\u0648 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629. \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u0625\u0639\u062f\u0627\u062f \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u060c \u0627\u0633\u062a\u062e\u062f\u0645 \u0647\u0630\u0627&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/micro-ohm-contact-resistance-testing\/\">\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0645\u064a\u0643\u0631\u0648 \u0623\u0648\u0645<\/a>.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0639\u062f\u0627\u062a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0623\u0648\u0645\u062a\u0631 \u0627\u0644\u0635\u063a\u064a\u0631: 100 \u0623\u0645\u0628\u064a\u0631 \u0623\u0648 200 \u0623\u0645\u0628\u064a\u0631 \u062a\u064a\u0627\u0631 \u0627\u062e\u062a\u0628\u0627\u0631 (\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649)<\/li>\n\n\n\n<li>\u0648\u0635\u0644\u0629 \u0643\u0644\u0641\u0646 (4 \u0623\u0633\u0644\u0627\u0643) \u0644\u0644\u062a\u062e\u0644\u0635 \u0645\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0633\u0644\u0643 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/li>\n\n\n\n<li>\u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629 \u062e\u0644\u0627\u0644 \u0622\u062e\u0631 12 \u0634\u0647\u0631\u064b\u0627<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0627\u0639\u0632\u0644 \u0627\u0644\u0642\u0627\u0637\u0639 \u062a\u0645\u0627\u0645\u064b\u0627 (\u062a\u062d\u0642\u0642 \u0645\u0646 \u0625\u0644\u063a\u0627\u0621 \u062a\u0646\u0634\u064a\u0637\u0647)<\/li>\n\n\n\n<li>\u0625\u063a\u0644\u0627\u0642 \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0642\u0648\u0627\u0637\u0639 (\u064a\u062f\u0648\u064a\u0627\u064b \u0623\u0648 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0627\u064b)<\/li>\n\n\n\n<li>\u0642\u0645 \u0628\u062a\u0648\u0635\u064a\u0644 \u0645\u0634\u0627\u0628\u0643 \u0643\u0644\u0641\u0646 \u0627\u0644\u0623\u0648\u0645\u064a\u062a\u0631 \u0627\u0644\u0635\u063a\u064a\u0631 \u0628\u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/li>\n\n\n\n<li>\u062a\u0637\u0628\u064a\u0642 \u062a\u064a\u0627\u0631 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0627\u0646\u062a\u0638\u0631 \u062d\u062a\u0649 \u062a\u0633\u062a\u0642\u0631 \u0627\u0644\u0642\u0631\u0627\u0621\u0629 (5-10 \u062b\u0648\u0627\u0646\u064d)<\/li>\n\n\n\n<li>\u0633\u062c\u0644 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0643\u0644 \u0642\u0637\u0628 \u0628\u0627\u0644\u0645\u064a\u0643\u0631\u0648\u0623\u0648\u0645 (\u03a9)<\/li>\n\n\n\n<li>\u0642\u064a\u0627\u0633 \u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0631\u0627\u062d\u0644 \u0627\u0644\u062b\u0644\u0627\u062b<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629 \u0644\u0623\u062c\u0647\u0632\u0629 VCB \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 12-36 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 \u062c\u062f\u064a\u062f\u0629<\/strong>: 30-80 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631 \u0644\u0643\u0644 \u0639\u0645\u0648\u062f<\/li>\n\n\n\n<li><strong>\u062d\u062f \u0627\u0644\u062e\u062f\u0645\u0629<\/strong>: 150 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631 \u0643\u062d\u062f \u0623\u0642\u0635\u0649<\/li>\n\n\n\n<li><strong>\u0639\u062a\u0628\u0629 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644<\/strong>: &gt;120 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631 \u0623\u0648 2 \u00d7 \u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633 \u0627\u0644\u0623\u0635\u0644\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0642\u064a\u064a\u0645<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629<\/th><th>\u0627\u0644\u0627\u062a\u062c\u0627\u0647<\/th><th>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/th><\/tr><\/thead><tbody><tr><td>&lt;80 \u03a9<\/td><td>\u0645\u0633\u062a\u0642\u0631<\/td><td>\u0645\u0642\u0628\u0648\u0644\u060c \u0645\u0648\u0627\u0635\u0644\u0629 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629<\/td><\/tr><tr><td>80-120 \u03a9<\/td><td>\u0627\u0644\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a\u0629<\/td><td>\u0627\u0644\u0631\u0635\u062f \u0641\u064a \u0627\u0644\u0641\u062a\u0631\u0629 \u0627\u0644\u0632\u0645\u0646\u064a\u0629 \u0627\u0644\u062a\u0627\u0644\u064a\u0629\u060c \u0648\u0627\u0644\u062a\u062e\u0637\u064a\u0637 \u0644\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644<\/td><\/tr><tr><td>&gt;120 \u03a9<\/td><td>\u0627\u0644\u0627\u0642\u062a\u0631\u0627\u0628 \u0645\u0646 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649<\/td><td>\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0639\u0646\u062f \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u0627\u0644\u064a<\/td><\/tr><tr><td>&gt;150 \u03a9<\/td><td>\u062a\u062c\u0627\u0648\u0632 \u062d\u062f \u0627\u0644\u062e\u062f\u0645\u0629<\/td><td>\u0645\u0637\u0644\u0648\u0628 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0641\u0648\u0631\u064a<\/td><\/tr><tr><td>\u0642\u0641\u0632\u0629 \u0645\u0641\u0627\u062c\u0626\u0629 (&gt;50% \u0632\u064a\u0627\u062f\u0629)<\/td><td>\u063a\u064a\u0631 \u0637\u0628\u064a\u0639\u064a<\/td><td>\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0644\u0644\u062a\u0623\u0643\u062f\u061b \u0625\u0630\u0627 \u062a\u0645 \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0630\u0644\u0643\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u0639\u062f\u0645 \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629 \u0623\u0648 \u0627\u0644\u062a\u0644\u0648\u062b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0628\u0627\u064a\u0646 \u0645\u0646 \u0642\u0637\u0628 \u0625\u0644\u0649 \u0642\u0637\u0628<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&lt;20% \u0627\u0644\u0641\u0631\u0642 = \u0645\u0642\u0628\u0648\u0644<\/li>\n\n\n\n<li>\u0627\u0644\u0641\u0631\u0642 30% = \u064a\u0634\u064a\u0631 \u0625\u0644\u0649 \u062a\u0622\u0643\u0644 \u063a\u064a\u0631 \u0645\u062a\u0633\u0627\u0648\u064d\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u062d\u0627\u0630\u0627\u0629 \u0627\u0644\u0622\u0644\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart.webp\" alt=\"\u0631\u0633\u0645 \u0628\u064a\u0627\u0646\u064a \u0644\u0627\u062a\u062c\u0627\u0647 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u064a\u0648\u0636\u062d \u0627\u0644\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a\u0629 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0645\u0639 \u062a\u062d\u062f\u064a\u062f \u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633 \u0648\u0639\u062a\u0628\u0629 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0648\u062d\u062f \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0644\u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629\" class=\"wp-image-2540\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0627\u0644\u0634\u0643\u0644 2**: \u064a\u062a\u064a\u062d \u0627\u062a\u062c\u0627\u0647 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0627\u0633\u062a\u0642\u0631\u0627\u0621 \u0627\u0644\u062e\u0637\u064a \u0627\u0644\u062a\u0646\u0628\u0624\u064a \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629 \u0645\u0646 \u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633 (50 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631\u064b\u0627) \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0646\u0637\u0642\u0629 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 (80 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631\u064b\u0627) \u064a\u062a\u0646\u0628\u0623 \u0628\u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0639\u062a\u0628\u0629 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 (120 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631\u064b\u0627) \u0642\u0628\u0644 6-12 \u0634\u0647\u0631\u064b\u0627\u060c \u0645\u0645\u0627 \u064a\u0633\u0645\u062d \u0628\u062c\u062f\u0648\u0644\u0629 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0645\u062e\u0637\u0637 \u0644\u0647 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0625\u0635\u0644\u0627\u062d\u0627\u062a \u0627\u0644\u0637\u0627\u0631\u0626\u0629.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-timing-and-travel-test\">2. \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0648\u0627\u0644\u0633\u0641\u0631<\/h3>\n\n\n\n<p>\u062a\u0639\u062a\u0645\u062f \u0642\u062f\u0631\u0629 \u0645\u0642\u0627\u0637\u0639\u0629 VCB \u0639\u0644\u0649 \u0633\u0631\u0639\u0629 \u0627\u0644\u0641\u062a\u062d. \u062a\u062a\u062d\u0642\u0642 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0645\u0646 \u0623\u062f\u0627\u0621 \u0627\u0644\u0622\u0644\u064a\u0629 \u0645\u0642\u0627\u0628\u0644 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0648\u064a\u0646\u0628\u063a\u064a \u0645\u0631\u0627\u062c\u0639\u062a\u0647\u0627 \u0645\u0639&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/vcb-contact-gap-adjustment-factory-field\/\">\u0641\u062c\u0648\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u062d\u062f\u0648\u062f \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629<\/a>&nbsp;\u0642\u0628\u0644 \u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0644\u0627\u0632\u0645\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062d\u0644\u0644 \u0627\u0644\u062a\u0648\u0642\u064a\u062a (\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u062a\u0648\u0642\u064a\u062a VCB \u0645\u062e\u0635\u0635\u0629)<\/li>\n\n\n\n<li>\u0623\u0648: \u0645\u0633\u062c\u0644 \u0639\u0627\u0644\u064a \u0627\u0644\u0633\u0631\u0639\u0629 \u0645\u0639 \u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0648\u0636\u0639 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/li>\n\n\n\n<li>\u062a\u0645\u062a \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629 \u062e\u0644\u0627\u0644 \u0622\u062e\u0631 12 \u0634\u0647\u0631\u064b\u0627<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a<\/strong>:<\/p>\n\n\n\n<p><strong>\u0648\u0642\u062a \u0627\u0644\u0627\u0641\u062a\u062a\u0627\u062d<\/strong>: \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0645\u0633\u062a\u063a\u0631\u0642 \u0645\u0646 \u062a\u0646\u0634\u064a\u0637 \u0645\u0644\u0641 \u0627\u0644\u0631\u062d\u0644\u0629 \u0625\u0644\u0649 \u0641\u0635\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629: 30-60 \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629 \u0644\u0640 12-24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a VCBs\u060c \u064850-80 \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629 \u0644\u0640 36-40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0648\u0642\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/strong>: \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0645\u0633\u062a\u063a\u0631\u0642 \u0645\u0646 \u062a\u0646\u0634\u064a\u0637 \u0627\u0644\u0645\u0644\u0641 \u0627\u0644\u0642\u0631\u064a\u0628 \u0625\u0644\u0649 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0628\u0627\u0644\u0644\u0645\u0633<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629: 60-100 \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0628\u0627\u0644\u0633\u0641\u0631<\/strong>: \u0625\u062c\u0645\u0627\u0644\u064a \u0627\u0644\u0645\u0633\u0627\u0641\u0629 \u0627\u0644\u062a\u064a \u062a\u062a\u062d\u0631\u0643 \u0641\u064a\u0647\u0627 \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0645\u0646 \u0627\u0644\u0641\u062a\u062d \u0627\u0644\u0643\u0627\u0645\u0644 \u0625\u0644\u0649 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0627\u0645\u0644<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629: 10-16 \u0645\u0645 \u0644 12-24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c 14-20 \u0645\u0645 \u0644 36-40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0633\u0631\u0639\u0629<\/strong>: \u0645\u062a\u0648\u0633\u0637 \u0633\u0631\u0639\u0629 \u0641\u0635\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0641\u062a\u062d<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629: 1.0 - 2.5 \u0645\/\u062b\u0627\u0646\u064a\u0629 (\u0622\u0644\u064a\u0627\u062a \u0632\u0646\u0628\u0631\u0643\u064a\u0629)\u060c 2.0 - 4.0 \u0645\/\u062b\u0627\u0646\u064a\u0629 (\u0645\u0634\u063a\u0644\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u062a\u0648\u0635\u064a\u0644 \u0645\u062d\u0644\u0644 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0628\u0645\u0644\u0627\u0645\u0633\u0627\u062a VCB \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629 \u0623\u0648 \u0645\u0633\u062a\u0634\u0639\u0631\u0627\u062a \u0645\u0648\u0636\u0639 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0645\u0628\u0627\u0634\u0631<\/li>\n\n\n\n<li>\u062a\u0634\u063a\u064a\u0644 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0631\u062d\u0644\u0629 \u0623\u062b\u0646\u0627\u0621 \u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u0645\u062d\u0644\u0644<\/li>\n\n\n\n<li>\u064a\u0639\u0631\u0636 \u0627\u0644\u0645\u062d\u0644\u0644 \u0632\u0645\u0646 \u0627\u0644\u0641\u062a\u062d\u060c \u0648\u0645\u0646\u062d\u0646\u0649 \u0627\u0644\u0633\u0641\u0631\u060c \u0648\u0627\u0644\u0633\u0631\u0639\u0629<\/li>\n\n\n\n<li>\u0643\u0631\u0631 \u0630\u0644\u0643 \u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0639\u0645\u0644\u064a\u0629<\/li>\n\n\n\n<li>\u0625\u062c\u0631\u0627\u0621 3 \u0642\u064a\u0627\u0633\u0627\u062a \u0644\u0643\u0644 \u0639\u0645\u0644\u064a\u0629\u060c \u0648\u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0646\u062a\u0627\u0626\u062c<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d: \u0641\u064a \u062d\u062f\u0648\u062f \u00b110% \u0645\u0646 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0644\u0648\u062d\u0629<\/li>\n\n\n\n<li>\u0648\u0642\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642: \u0641\u064a \u062d\u062f\u0648\u062f \u00b1 15% \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a (\u0623\u0642\u0644 \u0623\u0647\u0645\u064a\u0629 \u0645\u0646 \u0627\u0644\u0641\u062a\u062d)<\/li>\n\n\n\n<li>\u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0628\u0627\u0644\u0633\u0641\u0631: 90-110% \u0645\u0646 \u0627\u0644\u0633\u0641\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/li>\n\n\n\n<li>\u0627\u0644\u0633\u0631\u0639\u0629: &gt;80% \u0645\u0646 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0644\u0633\u0631\u0639\u0629 \u0627\u0644\u0645\u062d\u062f\u062f\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0638\u0631\u0648\u0641 \u062e\u0627\u0631\u062c\u0629 \u0639\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0623\u0639\u0631\u0627\u0636<\/th><th>\u0627\u0644\u0633\u0628\u0628 \u0627\u0644\u0645\u062d\u062a\u0645\u0644<\/th><th>\u0627\u0644\u0639\u0644\u0627\u062c<\/th><\/tr><\/thead><tbody><tr><td>\u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d \u0628\u0637\u064a\u0621 (&gt;10% \u0641\u0648\u0642 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a)<\/td><td>\u0645\u0648\u0627\u062f \u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0627\u0644\u0645\u062c\u0641\u0641\u0629\u060c \u0648\u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u060c \u0648\u0627\u0644\u0627\u062d\u062a\u0643\u0627\u0643<\/td><td>\u062a\u0632\u064a\u064a\u062a\u060c \u0648\u0636\u0628\u0637\u060c \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0646\u0648\u0627\u0628\u0636<\/td><\/tr><tr><td>\u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d \u0627\u0644\u0633\u0631\u064a\u0639 (&gt;10% \u062a\u062d\u062a \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a)<\/td><td>\u0646\u0648\u0627\u0628\u0636 \u0645\u0634\u062f\u0648\u062f\u0629 \u0623\u0643\u062b\u0631 \u0645\u0646 \u0627\u0644\u0644\u0627\u0632\u0645\u060c \u062a\u062e\u0645\u064a\u062f \u0645\u0646\u062e\u0641\u0636<\/td><td>\u0636\u0628\u0637 \u0634\u062f \u0627\u0644\u0646\u0627\u0628\u0636\u060c \u0648\u0641\u062d\u0635 \u0627\u0644\u0645\u062e\u0645\u0651\u062f<\/td><\/tr><tr><td>\u062a\u0648\u0642\u064a\u062a \u063a\u064a\u0631 \u0645\u062a\u0633\u0642 (\u064a\u062e\u062a\u0644\u0641 &gt;15% \u0628\u064a\u0646 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a)<\/td><td>\u0627\u0644\u062a\u062c\u0644\u064a\u062f\u060c \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u060c \u0648\u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0632\u0644\u0627\u062c<\/td><td>\u0641\u062d\u0635 \u0627\u0644\u0622\u0644\u064a\u0629 \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0628\u0627\u0644\u064a\u0629<\/td><\/tr><tr><td>\u0633\u0641\u0631 \u0645\u0646\u062e\u0641\u0636 (&lt;90%)<\/td><td>\u062a\u0622\u0643\u0644 \u0627\u0644\u0622\u0644\u064a\u0629\u060c \u0627\u0646\u062a\u0641\u0627\u062e \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062a\u0641\u0631\u064a\u063a)<\/td><td>\u0636\u0628\u0637 \u0627\u0644\u0622\u0644\u064a\u0629\u061b \u0641\u064a \u062d\u0627\u0644\u0629 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u0627\u0633\u062a\u0628\u062f\u0644 VI<\/td><\/tr><tr><td>\u0627\u0644\u0633\u0641\u0631 \u0627\u0644\u0645\u0641\u0631\u0637 (&gt;110%)<\/td><td>\u0641\u0642\u062f\u0627\u0646 \u0636\u0628\u0637 \u0627\u0644\u0625\u064a\u0642\u0627\u0641\u060c \u0648\u062e\u0637\u0631 \u0627\u0644\u062a\u0644\u0641 \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646 \u0627\u0644\u0625\u0641\u0631\u0627\u0637 \u0641\u064a \u0627\u0644\u0633\u0641\u0631<\/td><td>\u0636\u0628\u0637 \u0627\u0644\u062a\u0648\u0642\u0641\u0627\u062a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup.webp\" alt=\"\u0625\u0639\u062f\u0627\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u062a\u0648\u0642\u064a\u062a VCB \u064a\u064f\u0638\u0647\u0631 \u0645\u062d\u0644\u0644 \u062a\u0648\u0642\u064a\u062a \u0645\u062a\u0635\u0644 \u0628\u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u0639 \u0639\u0631\u0636 \u062a\u062a\u0628\u0639 \u0632\u0645\u0646 \u0627\u0644\u0641\u062a\u062d \u0648\u0642\u064a\u0627\u0633 \u0645\u0646\u062d\u0646\u0649 \u0627\u0646\u062a\u0642\u0627\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\" class=\"wp-image-2541\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0627\u0644\u0634\u0643\u0644 3**: \u064a\u0644\u062a\u0642\u0637 \u0645\u062d\u0644\u0644 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d \u0627\u0644\u062f\u0642\u064a\u0642 (\u062a\u0646\u0634\u064a\u0637 \u0645\u0644\u0641 \u0627\u0644\u0631\u062d\u0644\u0629 \u0625\u0644\u0649 \u0627\u0646\u0641\u0635\u0627\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633)\u060c \u0648\u0645\u0646\u062d\u0646\u0649 \u0627\u0646\u062a\u0642\u0627\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u060c \u0648\u0633\u0631\u0639\u0629 \u0627\u0644\u0627\u0646\u0641\u0635\u0627\u0644 - \u0648\u0647\u064a \u0645\u0639\u0644\u0645\u0627\u062a \u062d\u0627\u0633\u0645\u0629 \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0642\u062f\u0631\u0629 \u0645\u0642\u0627\u0637\u0639\u0629 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062a\u064a \u062a\u0637\u0627\u0628\u0642 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 (\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u064a\u062a\u0631\u0627\u0648\u062d \u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d \u0645\u0646 30-60 \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629 \u0644\u0645\u0631\u0643\u0628\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 12-24 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0641\u0648\u0644\u062a).\n<br><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-insulation-resistance-testing\">3. \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644<\/h3>\n\n\n\n<p>\u064a\u062a\u062d\u0642\u0642 \u0645\u0646 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0628\u064a\u0646 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u062d\u064a\u0629 \u0648\u0627\u0644\u0623\u0631\u0636\u060c \u0645\u0645\u0627 \u064a\u0645\u0646\u0639 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0633\u0631\u0628 \u0648\u0627\u0644\u0648\u0645\u064a\u0636.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0639\u062f\u0627\u062a<\/strong>: \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 (Megger)\u060c \u062c\u0647\u062f \u0627\u062e\u062a\u0628\u0627\u0631 2.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0648 5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/p>\n\n\n\n<p><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636<\/strong>&nbsp;(\u0643\u0644 \u0639\u0645\u0648\u062f \u0639\u0644\u0649 \u062d\u062f\u0629):\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u0641\u062a\u0648\u062d: \u0627\u062e\u062a\u0628\u0631 \u0639\u0628\u0631 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0641\u062a\u0648\u062d\u0629 \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636\u064a<\/li>\n\n\n\n<li>\u0627\u0644\u0642\u0628\u0648\u0644 &gt;1,000 \u0645\u062a\u0631 \u0645\u0643\u0639\u0628<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0645\u0631\u062d\u0644\u0629 \u0625\u0644\u0649 \u0645\u0631\u062d\u0644\u0629<\/strong>&nbsp;(\u0641\u062a\u062d \u0627\u0644\u0642\u0627\u0637\u0639):\n<ul class=\"wp-block-list\">\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u064a\u0646 \u0627\u0644\u0623\u0642\u0637\u0627\u0628 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629<\/li>\n\n\n\n<li>\u0627\u0644\u0642\u0628\u0648\u0644 &gt;1,000 \u0645\u062a\u0631 \u0645\u0643\u0639\u0628<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0632\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0623\u0633\u0644\u0627\u0643<\/li>\n\n\n\n<li>\u0627\u0644\u0642\u0628\u0648\u0644 &gt;10 \u0645\u064a\u062c\u0627 \u0623\u0648\u0645 (\u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0628\u0633\u0628\u0628 \u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0645\u062a\u0635\u0644\u0629)<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0645\u0646\u062e\u0641\u0636\u0629 \u0644\u0644\u0639\u0632\u0644<\/strong>&nbsp;(&lt;100 M\u03a9 \u0639\u0644\u0649 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u064a\u0634\u064a\u0631 \u0625\u0644\u0649: \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629\u060c \u0648\u0627\u0644\u062a\u0644\u0648\u062b\u060c \u0648\u0627\u0644\u062a\u0644\u0648\u062b\u060c \u0648\u0627\u0644\u062a\u062a\u0628\u0639\u060c \u0648\u062a\u0644\u0641 \u0627\u0644\u0639\u0632\u0644<\/li>\n\n\n\n<li>\u0627\u0644\u0625\u062c\u0631\u0627\u0621: \u062a\u062c\u0641\u064a\u0641 \u0648\u062a\u0646\u0638\u064a\u0641 \u0648\u0641\u062d\u0635 \u0627\u0644\u0634\u0642\u0648\u0642\/\u0627\u0644\u062a\u0644\u0641\u061b \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0639\u062f \u0627\u062a\u062e\u0627\u0630 \u0625\u062c\u0631\u0627\u0621 \u062a\u0635\u062d\u064a\u062d\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0643\u062b\u0631 \u0631\u0648\u0627\u062c\u0627\u064b<\/strong>: \u062a\u062a\u0628\u0639 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0628\u0645\u0631\u0648\u0631 \u0627\u0644\u0648\u0642\u062a. \u064a\u0634\u064a\u0631 \u0627\u0644\u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a \u0625\u0644\u0649 \u062a\u0637\u0648\u0631 \u0627\u0644\u0645\u0634\u0643\u0644\u0629 \u062d\u062a\u0649 \u0644\u0648 \u0643\u0627\u0646\u062a \u0644\u0627 \u062a\u0632\u0627\u0644 \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-vacuum-integrity-check\">4. \u0641\u062d\u0635 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a<\/h3>\n\n\n\n<p>\u062a\u0639\u062a\u0645\u062f \u0642\u0648\u0629 \u0639\u0627\u0632\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0639\u0644\u0649 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u062a\u0641\u0631\u064a\u063a \u0639\u0627\u0644\u064a (&lt;10-\u2074 \u0628\u0627\u0633\u0643\u0627\u0644). \u0642\u062f \u0644\u0627 \u064a\u0645\u0646\u0639 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u062d\u0645\u0644 \u0648\u0644\u0643\u0646\u0647 \u064a\u0641\u0634\u0644 \u0628\u0634\u0643\u0644 \u0643\u0627\u0631\u062b\u064a \u0623\u062b\u0646\u0627\u0621 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0639\u0637\u0644.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0637\u0631\u064a\u0642\u0629 1: \u0627\u062e\u062a\u0628\u0627\u0631 \u062a\u062d\u0645\u0651\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a<\/strong>&nbsp;(\u0627\u0644\u0623\u0643\u062b\u0631 \u062a\u062d\u062f\u064a\u062f\u0627\u064b)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0639\u062f\u0627\u062a<\/strong>: \u062c\u0647\u0627\u0632 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f\u060c 10-50 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0642\u0627\u0628\u0644 \u0644\u0644\u062a\u0639\u062f\u064a\u0644<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u0641\u062a\u0648\u062d \u0628\u0627\u0644\u0643\u0627\u0645\u0644<\/li>\n\n\n\n<li>\u062a\u0637\u0628\u064a\u0642 \u062c\u0647\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u062d\u0633\u0628 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 (\u0639\u0627\u062f\u0629\u064b 70-80% \u0645\u0646 \u062a\u0635\u0646\u064a\u0641 BIL)\n<ul class=\"wp-block-list\">\n<li>\u0645\u062b\u0627\u0644: 12 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f VCB\u060c 75 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a BIL \u2192 \u062a\u0637\u0628\u064a\u0642 ~ 55 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u0627\u0646\u062a\u0638\u0631 \u0644\u0645\u062f\u0629 1 \u062f\u0642\u064a\u0642\u0629<\/li>\n\n\n\n<li>\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0648\u0645\u064a\u0636<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0627\u0644\u0642\u0628\u0648\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0644\u0627 \u064a\u0648\u062c\u062f \u0648\u0645\u064a\u0636 \u0639\u0646\u062f \u062c\u0647\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 = \u0627\u0644\u0641\u0631\u0627\u063a \u0633\u0644\u064a\u0645<\/li>\n\n\n\n<li>\u0648\u0645\u064a\u0636 \u0623\u0642\u0644 \u0645\u0646 \u062c\u0647\u062f \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 = \u0641\u0634\u0644 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0642\u0627\u0637\u0639<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0637\u0631\u064a\u0642\u0629 2: \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0639\u0646\u062f \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636<\/strong>&nbsp;(\u0645\u0644\u0627\u0626\u0645\u0629 \u0645\u064a\u062f\u0627\u0646\u064a\u064b\u0627)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0642\u0645 \u0628\u062a\u0637\u0628\u064a\u0642 1,000 \u0625\u0644\u0649 2,500 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0639\u0628\u0631 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0641\u062a\u0648\u062d\u0629 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u064a\u062c\u0631<\/li>\n\n\n\n<li>\u062a\u0641\u0631\u064a\u063a \u062c\u064a\u062f: &gt; 100 \u0645\u062a\u0631 \u0645\u0643\u0639\u0628\u060c \u0642\u0631\u0627\u0621\u0629 \u0645\u0633\u062a\u0642\u0631\u0629<\/li>\n\n\n\n<li>\u062a\u0641\u0631\u064a\u063a \u0641\u0627\u0634\u0644: &lt;50 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631 \u0645\u0643\u0639\u0628\u060c \u0642\u0631\u0627\u0621\u0629 \u063a\u064a\u0631 \u0645\u0646\u062a\u0638\u0645\u0629\u060c \u0648\u0645\u064a\u0636 \u0645\u062d\u062a\u0645\u0644<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0623\u0642\u0644 \u062a\u062d\u062f\u064a\u062f\u0627\u064b \u0645\u0646 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u0644\u0643\u0646\u0647 \u0645\u0646\u0627\u0633\u0628 \u0644\u0644\u0641\u062d\u0635 \u0627\u0644\u0631\u0648\u062a\u064a\u0646\u064a.<\/strong><\/p>\n\n\n\n<p><strong>\u0627\u0644\u0637\u0631\u064a\u0642\u0629 3: \u0642\u064a\u0627\u0633 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0631\u0639<\/strong>&nbsp;(\u0645\u062a\u0642\u062f\u0645\u060c \u064a\u062a\u0637\u0644\u0628 \u0645\u0639\u062f\u0627\u062a \u0645\u062a\u062e\u0635\u0635\u0629)<\/p>\n\n\n\n<p>\u062a\u0648\u0641\u0631 \u0628\u0639\u0636 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0646\u0627\u0641\u0630 \u0642\u064a\u0627\u0633 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0631\u0639 \u0644\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u063a\u064a\u0631 \u0627\u0644\u062c\u0631\u0627\u062d\u064a.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-operating-mechanism-inspection\">5. \u0641\u062d\u0635 \u0622\u0644\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/h3>\n\n\n\n<p><strong>\u0641\u062d\u0635 \u0627\u0644\u062a\u0634\u062d\u064a\u0645<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062d\u0627\u0644\u0629 \u0627\u0644\u0634\u062d\u0648\u0645<\/strong>: \u0646\u0638\u064a\u0641\u060c \u0642\u0648\u0627\u0645 \u0645\u0646\u0627\u0633\u0628 (\u063a\u064a\u0631 \u062c\u0627\u0641\u060c \u063a\u064a\u0631 \u0633\u0627\u0626\u0644)<\/li>\n\n\n\n<li><strong>\u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0634\u062d\u064a\u0645<\/strong>: \u062c\u0645\u064a\u0639 \u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0645\u062d\u0648\u0631\u064a\u0629 \u0648\u0627\u0644\u0623\u0633\u0637\u062d \u0627\u0644\u0645\u0646\u0632\u0644\u0642\u0629 \u0648\u0627\u0644\u0648\u0635\u0644\u0627\u062a<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0644\u0648\u062b<\/strong>: \u0627\u0644\u0634\u062d\u0648\u0645 \u063a\u064a\u0631 \u0627\u0644\u0645\u0644\u0648\u062b\u0629 \u0628\u0627\u0644\u063a\u0628\u0627\u0631\/\u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0625\u062c\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0646\u0638\u064a\u0641 \u0627\u0644\u0634\u062d\u0648\u0645 \u0627\u0644\u0642\u062f\u064a\u0645\u0629 \u0645\u0646 \u0627\u0644\u0645\u062d\u0627\u0645\u0644\u060c \u0648\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0645\u062d\u0648\u0631\u064a\u0629<\/li>\n\n\n\n<li>\u0636\u0639 \u0632\u064a\u062a \u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0627\u0644\u0645\u062d\u062f\u062f \u0645\u0646 \u0642\u0628\u0644 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 (\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u064a\u0643\u0648\u0646 \u0623\u0633\u0627\u0633\u0647 \u0627\u0644\u0644\u064a\u062b\u064a\u0648\u0645\u060c \u0648\u0645\u064f\u0642\u064a\u064e\u0651\u0645 \u0645\u0646 -40 \u0625\u0644\u0649 +125 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629)<\/li>\n\n\n\n<li>\u062a\u062c\u0646\u0628 \u0627\u0644\u0625\u0641\u0631\u0627\u0637 \u0641\u064a \u0627\u0644\u062a\u0634\u062d\u064a\u0645 (\u064a\u062c\u0630\u0628 \u0627\u0644\u063a\u0628\u0627\u0631)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0641\u062d\u0635 \u0627\u0644\u062a\u0622\u0643\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u062b\u0642\u0648\u0628 \u0627\u0644\u0645\u062d\u0648\u0631\u064a\u0629<\/strong>: \u0641\u062d\u0635 \u0627\u0644\u0627\u0633\u062a\u0637\u0627\u0644\u0629 \u0648\u0627\u0644\u062a\u0622\u0643\u0644 \u0627\u0644\u0628\u064a\u0636\u0627\u0648\u064a<\/li>\n\n\n\n<li><strong>\u062f\u0628\u0627\u0628\u064a\u0633 \u0627\u0644\u0631\u0628\u0637<\/strong>: \u0642\u064a\u0627\u0633 \u0627\u0644\u0642\u0637\u0631\u060c \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062a\u0622\u0643\u0644<\/li>\n\n\n\n<li><strong>\u0627\u0644\u064a\u0646\u0627\u0628\u064a\u0639<\/strong>: \u0641\u062d\u0635 \u0627\u0644\u0634\u0642\u0648\u0642 \u0648\u0627\u0644\u062a\u0634\u0648\u0647 \u0627\u0644\u062f\u0627\u0626\u0645<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0645\u0632\u0627\u0644\u062c<\/strong>: \u0641\u062d\u0635 \u0627\u0644\u0628\u0644\u0649 \u0648\u0627\u0644\u062a\u0642\u0637\u064a\u0639 \u0648\u0627\u0644\u062a\u0644\u0641 \u0627\u0644\u0633\u0637\u062d\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0641\u062c\u0648\u0629 \u062a\u0644\u0627\u0645\u0633 \u0645\u062a\u0633\u0627\u0648\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0637\u0627\u0628 \u0627\u0644\u062b\u0644\u0627\u062b\u0629 \u0639\u0646\u062f \u0627\u0644\u0641\u062a\u062d<\/li>\n\n\n\n<li>\u0625\u062c\u0631\u0627\u0621\/\u0643\u0633\u0631 \u062a\u0644\u0627\u0645\u0633 \u0645\u062a\u0632\u0627\u0645\u0646 \u0639\u0628\u0631 \u0627\u0644\u0642\u0637\u0628\u064a\u0646 (\u0641\u064a \u062d\u062f\u0648\u062f \u062a\u0641\u0627\u0648\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0651\u0639\u0629\u060c \u0639\u0627\u062f\u0629\u064b &lt;3 \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629)<\/li>\n\n\n\n<li>\u0644\u0627 \u064a\u0648\u062c\u062f \u0627\u0646\u062d\u0646\u0627\u0621 \u0623\u0648 \u0627\u0646\u062d\u0631\u0627\u0641 \u0645\u0631\u0626\u064a \u0641\u064a \u0622\u0644\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6.-auxiliary-circuit-and-relay-coordination-check\">6. \u0641\u062d\u0635 \u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629 \u0648\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062a\u0631\u062d\u064a\u0644\u0627\u062a<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u062a\u062a\u0627\u0628\u0639 \u0627\u0644\u0645\u0627\u0646\u0639 \u0644\u0644\u0636\u062e<\/li>\n\n\n\n<li>\u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0625\u0639\u0627\u062f\u0629 \u062a\u0639\u064a\u064a\u0646 \u0645\u0631\u062d\u0644 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/li>\n\n\n\n<li>\u062f\u0642\u0629 \u0628\u064a\u0627\u0646 \u0627\u0644\u0645\u0648\u0642\u0639<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0645\u0631\u062d\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u062a\u0637\u0627\u0628\u0642 \u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u062a\u0642\u0627\u0637 \u0627\u0644\u062a\u062a\u0627\u0628\u0639 \u0648\u0627\u0644\u062a\u0623\u062e\u064a\u0631 \u0627\u0644\u0632\u0645\u0646\u064a \u0645\u0639 \u062f\u0631\u0627\u0633\u0629 \u0627\u0644\u062a\u0646\u0633\u064a\u0642<\/li>\n\n\n\n<li>\u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0646\u062d\u0631\u0627\u0641 \u062a\u0648\u0642\u064a\u062a VCB\u060c \u0642\u062f \u064a\u062d\u062a\u0627\u062c \u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0639\u062f\u064a\u0644<\/li>\n\n\n\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0630\u0627\u062a\u064a \u0644\u0644\u062a\u0631\u062d\u064a\u0644 (\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0627\u062a \u0627\u0644\u062f\u0642\u064a\u0642\u0629)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0628\u0634\u0627\u0631\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0646 \u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 \u0627\u0644\u0625\u0646\u0630\u0627\u0631 \u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d<\/li>\n\n\n\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f (SCADA\u060c \u0623\u0636\u0648\u0627\u0621 \u0627\u0644\u0644\u0648\u062d\u0629)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-record-template\">\u0642\u0627\u0644\u0628 \u0627\u0644\u0633\u062c\u0644 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template.webp\" alt=\"\u0642\u0627\u0644\u0628 \u0633\u062c\u0644 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0644\u0633\u062c\u0644 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0644\u0628\u0646\u0643 VCB \u064a\u0648\u0636\u062d \u0631\u0623\u0633 \u0627\u0644\u0645\u0639\u062f\u0627\u062a\u060c \u0648\u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0641\u0635\u0644\u064a\u0629\u060c \u0648\u062d\u0642\u0648\u0644 \u0642\u064a\u0627\u0633 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0633\u0646\u0648\u064a\u060c \u0648\u0623\u0642\u0633\u0627\u0645 \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0644\u062c\u0645\u0639 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0628\u0634\u0643\u0644 \u0645\u0646\u0647\u062c\u064a\" class=\"wp-image-2542\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0627\u0644\u0634\u0643\u0644 4**: \u064a\u0636\u0645\u0646 \u0642\u0627\u0644\u0628 \u0627\u0644\u0633\u062c\u0644 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0627\u0644\u0645\u0648\u062d\u062f \u062c\u0645\u0639 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0628\u0634\u0643\u0644 \u0645\u062a\u0633\u0642 \u0639\u0628\u0631 \u062f\u0648\u0631\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 - \u064a\u0644\u062a\u0642\u0637 \u0627\u0644\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0645\u0646\u0638\u0645 \u0647\u0648\u064a\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0641\u0635\u0644\u064a\u0629 \u0648\u0642\u064a\u0645 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0648\u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u0635\u062d\u064a\u062d\u064a\u0629 \u0648\u062c\u062f\u0648\u0644 \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u062a\u0627\u0644\u064a \u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u0641\u0639\u0627\u0644\u0629 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0627\u0644\u062a\u0646\u0638\u064a\u0645\u064a.\n<br><\/figcaption><\/figure>\n\n\n\n<p>\u064a\u062a\u064a\u062d \u0627\u0644\u062a\u0648\u062b\u064a\u0642 \u0627\u0644\u0645\u062a\u0633\u0642 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a. \u0627\u0633\u062a\u062e\u062f\u0645 \u0647\u0630\u0627 \u0627\u0644\u0642\u0627\u0644\u0628 \u0623\u0648 \u0642\u0645 \u0628\u062a\u0643\u064a\u064a\u0641\u0647 \u0645\u0639 \u0646\u0638\u0627\u0645 \u0625\u062f\u0627\u0631\u0629 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0630\u062e\u0627\u0626\u0631 \u0627\u0644\u0639\u0646\u0642\u0648\u062f\u064a\u0629 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>\u0633\u062c\u0644 \u0635\u064a\u0627\u0646\u0629 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\n\n\u0645\u0639\u0631\u0641 \u0627\u0644\u0645\u0639\u062f\u0627\u062a: ________________ \u0627\u0644\u0645\u0648\u0642\u0639: ________________\n\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629: ________________ \u0627\u0644\u0631\u0642\u0645 \u0627\u0644\u062a\u0633\u0644\u0633\u0644\u064a: ________________\n\u0627\u0644\u0641\u0648\u0644\u0637\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629: _______ \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u062f\u0631: _______ A\n\u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629: _______ \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u0633\u0646\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628: _______\n\n\u0646\u0648\u0639 \u0627\u0644\u0635\u064a\u0627\u0646\u0629: [] \u0631\u0628\u0639 \u0633\u0646\u0648\u064a [] \u0633\u0646\u0648\u064a [] \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u0639\u0637\u0644 [] \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u0639\u0637\u0644\n\u0627\u0644\u062a\u0627\u0631\u064a\u062e: _______________ \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0645\u0646\u0630 \u0622\u062e\u0631 \u0641\u062d\u0635: _______\n\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629: _____ \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629: _____ %\n\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n\n\u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0641\u0635\u0644\u064a\u0629 (\u0625\u0646 \u0648\u062c\u062f\u062a):\n\n\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a:\n[] \u0646\u0638\u064a\u0641 \u0645\u0646 \u0627\u0644\u062e\u0627\u0631\u062c\u060c \u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u0639\u0642\u0628\n[] \u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u0644\u0641 \u0645\u0627\u062f\u064a \u0623\u0648 \u062a\u0634\u0642\u0642\u0627\u062a\n[ ] \u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u0631\u0637\u0648\u0628\u0629\/\u062a\u0622\u0643\u0644\n[] \u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0643\u0627\u0641\u064a\u0629\n\n\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a:\n[] \u064a\u063a\u0644\u0642 \u0628\u0633\u0644\u0627\u0633\u0629 [] \u064a\u063a\u0644\u0642 \u0628\u0633\u0644\u0627\u0633\u0629\n[] \u064a\u0646\u0637\u0644\u0642 \u0639\u0644\u0649 \u0627\u0644\u0641\u0648\u0631\n[] \u0627\u0644\u0625\u0642\u0641\u0627\u0644 \u0628\u0625\u064a\u062c\u0627\u0628\u064a\u0629\n[] \u062a\u0648\u0642\u0641 \u0645\u062d\u0631\u0643 \u0627\u0644\u0634\u062d\u0646 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d\n\n\u062c\u0647\u062f \u0627\u0644\u062a\u062d\u0643\u0645 (\u0645\u0642\u064a\u0633):\n\u0645\u0644\u0641 \u0627\u0644\u062a\u0639\u062b\u0631 _______ \u0641\u0648\u0644\u062a (\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a: 85-110% \u0645\u0646 _____ \u0641\u0648\u0644\u062a)\n\u0645\u0644\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642: _______ V\n\u0645\u0633\u0627\u0639\u062f: _______ V\n\n\u0641\u062d\u0635 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a:\n[] \u0644\u0645 \u064a\u062a\u0645 \u0645\u0644\u0627\u062d\u0638\u0629 \u0623\u064a \u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0645\u0641\u0643\u0648\u0643\u0629\n[] \u0644\u0627 \u064a\u0648\u062c\u062f \u062a\u063a\u064a\u0631 \u0641\u064a \u0627\u0644\u0644\u0648\u0646 \u062d\u0648\u0644 \u0627\u0644\u0623\u0637\u0631\u0627\u0641\n\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n\n\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0633\u0646\u0648\u064a\u0629 (\u0625\u0646 \u0648\u062c\u062f\u062a):\n\n\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 (\u03bc\u03a9):\n\u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u0623: _______ (\u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633: _____) \u0627\u0644\u062d\u0627\u0644\u0629: [] \u0645\u0648\u0627\u0641\u0642 [] \u0645\u0631\u0627\u0642\u0628\u0629 [] \u0627\u0633\u062a\u0628\u062f\u0627\u0644 [] \u0627\u0633\u062a\u0628\u062f\u0627\u0644\n\u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u0628: _______ (\u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633: _____) \u0627\u0644\u062d\u0627\u0644\u0629: [ ] \u0645\u0648\u0627\u0641\u0642 [ ] \u0645\u0631\u0627\u0642\u0628\u0629 [ ] \u0627\u0633\u062a\u0628\u062f\u0627\u0644: [] \u0645\u0648\u0627\u0641\u0642 [] \u0645\u0631\u0627\u0642\u0628\u0629 [] \u0627\u0633\u062a\u0628\u062f\u0627\u0644 [] \u0627\u0633\u062a\u0628\u062f\u0627\u0644\n\u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u062c: _______ (\u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633: _____) \u0627\u0644\u062d\u0627\u0644\u0629: [ ] \u0645\u0648\u0627\u0641\u0642 [ ] \u0645\u0631\u0627\u0642\u0628\u0629 [ ] \u0627\u0633\u062a\u0628\u062f\u0627\u0644: [ ] \u0645\u0648\u0627\u0641\u0642 [ ] \u0645\u0631\u0627\u0642\u0628\u0629 [ ] \u0627\u0633\u062a\u0628\u062f\u0627\u0644 [ ] \u0627\u0644\u062d\u0627\u0644\u0629: [ ] \u0645\u0648\u0627\u0641\u0642 [ ] \u0645\u0631\u0627\u0642\u0628\u0629 [ ] \u0627\u0633\u062a\u0628\u062f\u0627\u0644\n\n\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0648\u0642\u064a\u062a:\n\u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d _______ \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629 (\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a: _____ \u00b1 _____ \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\u0648\u0642\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642: _______ \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629 (\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a: _____ \u00b1 _____ \u0645\u0644\u0644\u064a \u062b\u0627\u0646\u064a\u0629) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\u0648\u0642\u062a \u0627\u0644\u062a\u0644\u0627\u0645\u0633 _______ \u0645\u0645 (\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a: _____ \u00b1 _____ \u0645\u0645) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0633\u0631\u0639\u0629: _______ \u0645\/\u062b\u0627\u0646\u064a\u0629 (\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u062f\u0646\u064a\u0627: _____ \u0645\/\u062b\u0627\u0646\u064a\u0629) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\n\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 (m\u03c9):\n\u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u0623 \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636 _______ (\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649: 1000 \u0645 \u0623\u0648\u0645) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\u0627\u0644\u0645\u0631\u062d\u0644\u0629 B \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636: _______ (\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649: 1000 M\u03a9) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\u0627\u0644\u0645\u0631\u062d\u0644\u0629 C \u0625\u0644\u0649 \u0627\u0644\u0623\u0631\u0636: _______ (\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649: 1000 M\u03a9) [] \u062a\u0645\u0631\u064a\u0631 [] \u0641\u0634\u0644\n\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645: _______ (\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649: 10 M\u03a9) [] \u0646\u062c\u0627\u062d [] \u0641\u0634\u0644\n\n\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\n\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629: [] \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0627\u0644\u0635\u0645\u0648\u062f [] \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u064a\u062c\u0631 [] \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0631\u0639\n\u0627\u0644\u0646\u062a\u064a\u062c\u0629: [] \u0646\u062c\u0627\u062d (\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a) [] \u0641\u0634\u0644 (\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062a\u0641\u0631\u064a\u063a)\n\u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0634\u0644: \u0645\u0637\u0644\u0648\u0628 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0642\u0627\u0637\u0639: [] \u0646\u0639\u0645 [] \u0646\u0639\u0645\n\n\u0641\u062d\u0635 \u0627\u0644\u0622\u0644\u064a\u0629:\n[] \u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0645\u0642\u0628\u0648\u0644\u0629\n[] \u0644\u0645 \u064a\u0644\u0627\u062d\u0638 \u0623\u064a \u062a\u0622\u0643\u0644 \u0645\u0641\u0631\u0637\n[] \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629 \u0636\u0645\u0646 \u0627\u0644\u062a\u0641\u0627\u0648\u062a \u0627\u0644\u0645\u0633\u0645\u0648\u062d \u0628\u0647\n[] \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u0627\u062a \u0641\u064a \u062d\u0627\u0644\u0629 \u062c\u064a\u062f\u0629\n\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n\n\u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u0635\u062d\u064a\u062d\u064a\u0629 \u0627\u0644\u0645\u062a\u062e\u0630\u0629\n____________________________________________________________\n____________________________________________________________\n\n\u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u0633\u062a\u0628\u062f\u0644\u0629:\n____________________________________________________________\n\n\u0645\u0648\u0639\u062f \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u062a\u0627\u0644\u064a\n\u0627\u0644\u062a\u0627\u0631\u064a\u062e: _______________ \u0623\u0648 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a: _______\n\n\u062d\u0627\u0644\u0629 \u0627\u0644\u0642\u0627\u0637\u0639:\n[] \u0639\u0627\u062f \u0625\u0644\u0649 \u0627\u0644\u062e\u062f\u0645\u0629 (\u062a\u0645 \u0627\u062c\u062a\u064a\u0627\u0632 \u062c\u0645\u064a\u0639 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a)\n[ ] \u062e\u0627\u0631\u062c \u0627\u0644\u062e\u062f\u0645\u0629 (\u064a\u0644\u0632\u0645 \u0625\u062c\u0631\u0627\u0621 \u0625\u0635\u0644\u0627\u062d\u0627\u062a)\n[] \u062a\u0645 \u062a\u062d\u062f\u064a\u062f \u0645\u0648\u0639\u062f \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0642\u0627\u0637\u0639: _______________\n\n\u0627\u0644\u0645\u0641\u062a\u0634 _____________________ Signature: __________\n\u062a\u0645\u062a \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0645\u0646 \u0642\u0628\u0644: ___________________ \u0627\u0644\u062a\u0627\u0631\u064a\u062e: ____________\n<\/code><\/pre>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"trending-and-predictive-maintenance\">\u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629<\/h2>\n\n\n\n<p>\u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \u0647\u064a \u0644\u0642\u0637\u0627\u062a \u0633\u0631\u064a\u0639\u0629. \u062a\u0643\u0634\u0641 \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0639\u0646 \u0623\u0646\u0645\u0627\u0637 \u0627\u0644\u062a\u062f\u0647\u0648\u0631.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0639\u0644\u0645\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0644\u0627\u062a\u062c\u0627\u0647<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u0627\u0631\u0633\u0645 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0643\u0644 \u0639\u0645\u0648\u062f<\/li>\n\n\n\n<li>\u064a\u062a\u0646\u0628\u0623 \u0627\u0644\u0627\u0633\u062a\u0642\u0631\u0627\u0621 \u0627\u0644\u062e\u0637\u064a \u0628\u0646\u0642\u0637\u0629 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644<\/li>\n\n\n\n<li>\u0645\u062b\u0627\u0644: \u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0644\u0632\u064a\u0627\u062f\u0629 \u0645\u0646 50 \u0645\u064a\u0643\u0631\u0648 \u0623\u0648\u0645 \u0625\u0644\u0649 90 \u0645\u064a\u0643\u0631\u0648 \u0623\u0648\u0645 \u0639\u0644\u0649 1500 \u0639\u0645\u0644\u064a\u0629\u060c \u062a\u0648\u0642\u0639 \u0623\u0646 \u062a\u0635\u0644 \u0625\u0644\u0649 \u062d\u062f 120 \u0645\u064a\u0643\u0631\u0648 \u0623\u0648\u0645 \u0639\u0646\u062f \u062d\u0648\u0627\u0644\u064a 2800 \u0639\u0645\u0644\u064a\u0629<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0648\u0642\u062a \u0627\u0644\u0627\u0641\u062a\u062a\u0627\u062d \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0648\u0642\u062a<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a\u0629 \u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u062a\u0622\u0643\u0644 \u0627\u0644\u0622\u0644\u064a\u0629 \u0648\u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u062a\u0632\u064a\u064a\u062a<\/li>\n\n\n\n<li>\u062a\u0634\u064a\u0631 \u0627\u0644\u0642\u0641\u0632\u0629 \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u0629 \u0625\u0644\u0649 \u0639\u0637\u0644 \u0645\u0639\u064a\u0646 (\u0627\u0644\u0632\u0646\u0628\u0631\u0643\u060c \u0627\u0644\u0648\u0635\u0644\u0629)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0632\u0645\u0646<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u0627\u0646\u062e\u0641\u0627\u0636 \u062a\u062f\u0631\u064a\u062c\u064a \u0637\u0628\u064a\u0639\u064a (\u0627\u0644\u0634\u064a\u062e\u0648\u062e\u0629)<\/li>\n\n\n\n<li>\u064a\u0634\u064a\u0631 \u0627\u0644\u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0633\u0631\u064a\u0639 \u0625\u0644\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0627\u0644\u062a\u0644\u0648\u062b \u0648\u0627\u0644\u062a\u0644\u0641<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062c\u062f\u0648\u0644\u0629 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644<\/strong>&nbsp;\u0639\u0646\u062f\u0645\u0627 \u064a\u0634\u064a\u0631 \u0627\u0644\u0627\u062a\u062c\u0627\u0647 \u0625\u0644\u0649 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u062d\u062f \u0627\u0644\u062e\u062f\u0645\u0629 \u062e\u0644\u0627\u0644 6-12 \u0634\u0647\u0631\u064b\u0627 \u0627\u0644\u0642\u0627\u062f\u0645\u0629<\/li>\n\n\n\n<li><strong>\u062e\u0637\u0629 \u0627\u0644\u0625\u0635\u0644\u0627\u062d \u0627\u0644\u0634\u0627\u0645\u0644 \u0644\u0644\u0622\u0644\u064a\u0629<\/strong>&nbsp;\u0639\u0646\u062f\u0645\u0627 \u064a\u0642\u062a\u0631\u0628 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0645\u0646 \u062d\u062f \u00b110%<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u062d\u0642\u064a\u0642 \u0641\u064a \u0627\u0644\u0631\u0642\u0627\u0628\u0629 \u0627\u0644\u0628\u064a\u0626\u064a\u0629<\/strong>&nbsp;\u0625\u0630\u0627 \u0627\u0646\u062e\u0641\u0636\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0628\u0634\u0643\u0644 \u0623\u0633\u0631\u0639 \u0645\u0646 \u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0623\u0633\u0637\u0648\u0644<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u0623\u0633\u0637\u0648\u0644<\/strong>:<\/p>\n\n\n\n<p>\u0625\u0630\u0627 \u0643\u0646\u062a \u062a\u062d\u062a\u0641\u0638 \u0628\u0639\u062f\u0629 \u0628\u0646\u0648\u0643 \u0631\u0623\u0633 \u0645\u0627\u0644 \u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0645\u062a\u0637\u0627\u0628\u0642\u0629\u060c \u0642\u0627\u0631\u0646:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u0627 \u0647\u064a \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u062d\u0644\u0644 \u0628\u0634\u0643\u0644 \u0623\u0633\u0631\u0639\u061f (\u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0627\u0644\u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0623\u0648 \u0627\u062e\u062a\u0644\u0627\u0641\u0627\u062a \u0627\u0644\u0639\u0645\u0644)<\/li>\n\n\n\n<li>\u0647\u0644 \u062a\u0638\u0647\u0631 \u062c\u0645\u064a\u0639 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0645\u0646 \u062f\u0641\u0639\u0629 \u062a\u0635\u0646\u064a\u0639 \u0645\u062d\u062f\u062f\u0629 \u0645\u0634\u0627\u0643\u0644 \u0645\u0645\u0627\u062b\u0644\u0629\u061f (\u0639\u064a\u0628 \u0645\u062d\u062a\u0645\u0644 \u0641\u064a \u0627\u0644\u062a\u0635\u0645\u064a\u0645\/\u0627\u0644\u062a\u0635\u0646\u064a\u0639)<\/li>\n\n\n\n<li>\u0647\u0644 \u064a\u0624\u062b\u0631 \u062a\u0643\u0631\u0627\u0631 \u0627\u0644\u0641\u0627\u0635\u0644 \u0627\u0644\u0632\u0645\u0646\u064a \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0639\u0644\u0649 \u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u0644\u0641\u061f (\u062a\u062d\u0633\u064a\u0646 \u0627\u0644\u0641\u0627\u0635\u0644 \u0627\u0644\u0632\u0645\u0646\u064a)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-problems-and-troubleshooting\">\u0627\u0644\u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0648\u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0623\u0639\u0631\u0627\u0636<\/th><th>\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0634\u062e\u064a\u0635\u064a<\/th><th>\u0627\u0644\u0633\u0628\u0628 \u0627\u0644\u0645\u062d\u062a\u0645\u0644<\/th><th>\u0627\u0644\u0639\u0644\u0627\u062c<\/th><\/tr><\/thead><tbody><tr><td><strong>\u0644\u0646 \u062a\u062a\u0639\u062b\u0631<\/strong><\/td><td>\u0627\u0641\u062d\u0635 \u062c\u0647\u062f \u0645\u0644\u0641 \u0627\u0644\u0631\u062d\u0644\u0629<\/td><td>\u062c\u0647\u062f \u0645\u0646\u062e\u0641\u0636\u060c \u062f\u0627\u0626\u0631\u0629 \u0645\u0641\u062a\u0648\u062d\u0629<\/td><td>\u062a\u0635\u062d\u064a\u062d \u0625\u0645\u062f\u0627\u062f \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0625\u0635\u0644\u0627\u062d \u0627\u0644\u0623\u0633\u0644\u0627\u0643<\/td><\/tr><tr><td><\/td><td>\u0641\u062d\u0635 \u0627\u0644\u0648\u0635\u0644\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/td><td>\u062a\u062c\u0644\u064a\u062f\u060c \u0645\u0631\u0628\u0649 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/td><td>\u0622\u0644\u064a\u0629 \u062d\u0631\u0629\u060c \u062a\u0632\u064a\u064a\u062a<\/td><\/tr><tr><td><\/td><td>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0645\u0636\u0627\u062f\u0629 \u0644\u0644\u0636\u062e<\/td><td>\u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0627\u0630\u0628<\/td><td>\u0625\u0639\u0627\u062f\u0629 \u062a\u0639\u064a\u064a\u0646 \u0627\u0644\u0645\u0631\u062d\u0644\u060c \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062f\u0627\u0626\u0631\u0629<\/td><\/tr><tr><td><strong>\u0644\u0646 \u064a\u063a\u0644\u0642<\/strong><\/td><td>\u0627\u0641\u062d\u0635 \u062c\u0647\u062f \u0627\u0644\u0645\u0644\u0641 \u0627\u0644\u0645\u063a\u0644\u0642<\/td><td>\u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f\u060c \u062a\u0639\u0637\u0644 \u0627\u0644\u0645\u0644\u0641<\/td><td>\u0627\u0644\u0625\u0645\u062f\u0627\u062f \u0627\u0644\u0635\u062d\u064a\u062d\u060c \u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0645\u0644\u0641<\/td><\/tr><tr><td><\/td><td>\u0634\u062d\u0646 \u0622\u0644\u064a\u0629 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0634\u062d\u0646<\/td><td>\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u060c \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a \u0645\u0646\u062e\u0641\u0636<\/td><td>\u0622\u0644\u064a\u0629 \u0627\u0644\u0634\u062d\u0646<\/td><\/tr><tr><td><\/td><td>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u062a\u0639\u0634\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u062a\u062f\u0627\u062e\u0644\u0629<\/td><td>\u062a\u0639\u0634\u064a\u0642 \u064a\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td><td>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u0639\u0634\u064a\u0642\u060c \u0645\u0633\u062d \u0627\u0644\u0639\u0637\u0644<\/td><\/tr><tr><td><strong>\u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d \u0627\u0644\u0628\u0637\u064a\u0621<\/strong><\/td><td>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0648\u0642\u064a\u062a<\/td><td>\u062c\u0641\u0627\u0641 \u0627\u0644\u062a\u0632\u064a\u064a\u062a\u060c \u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td><td>\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0648\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0646\u0648\u0627\u0628\u0636<\/td><\/tr><tr><td><\/td><td>\u0642\u064a\u0627\u0633 \u0642\u0648\u0629 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td><td>\u0632\u0646\u0628\u0631\u0643 \u0636\u0639\u064a\u0641<\/td><td>\u0627\u0633\u062a\u0628\u062f\u0644 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td><\/tr><tr><td><strong>\u0627\u0631\u062a\u062f\u0627\u062f \u0627\u0644\u0627\u062a\u0635\u0627\u0644<\/strong><\/td><td>\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u062a\u062a\u0628\u0639 \u0627\u0644\u0632\u0645\u0646\u064a<\/td><td>\u0633\u0631\u0639\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0632\u0627\u0626\u062f\u0629\u060c \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062a\u062e\u0645\u064a\u062f<\/td><td>\u0627\u0636\u0628\u0637 \u0633\u0631\u0639\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0627\u0633\u062a\u0628\u062f\u0644 \u0627\u0644\u0645\u062e\u0645\u062f<\/td><\/tr><tr><td><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0639\u0627\u0644\u064a\u0629 \u0644\u0644\u062a\u0644\u0627\u0645\u0633<\/strong><\/td><td>\u0627\u062a\u062c\u0627\u0647 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629<\/td><td>\u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0627\u062e\u062a\u0644\u0627\u0644 \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629<\/td><td>\u0646\u0638\u0641 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a (\u0625\u0630\u0627 \u0643\u0627\u0646 \u064a\u0645\u0643\u0646 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u064a\u0647\u0627)\u060c \u0627\u0633\u062a\u0628\u062f\u0644\u0647\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 &gt; \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649<\/td><\/tr><tr><td><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0645\u0646\u062e\u0641\u0636\u0629 \u0644\u0644\u0639\u0632\u0644<\/strong><\/td><td>\u0627\u0644\u0642\u064a\u0627\u0633 \u062a\u062d\u062a \u0631\u0637\u0648\u0628\u0629 \u0645\u0636\u0628\u0648\u0637\u0629<\/td><td>\u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/td><td>\u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u0644\u0648\u062d\u0629\u060c \u0648\u062a\u062d\u0633\u064a\u0646 \u0627\u0644\u062e\u062a\u0645<\/td><\/tr><tr><td><\/td><td>\u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a<\/td><td>\u0627\u0644\u062a\u0644\u0648\u062b\u060c \u0627\u0644\u062a\u062a\u0628\u0639<\/td><td>\u0646\u0638\u0641 \u0627\u0644\u0639\u0648\u0627\u0632\u0644\u060c \u0648\u0627\u0633\u062a\u0628\u062f\u0644\u0647\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u062c\u0646\u0632\u0631\u0629<\/td><\/tr><tr><td><strong>\u0641\u0634\u0644 \u0641\u064a \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a<\/strong><\/td><td>\u0627\u062e\u062a\u0628\u0627\u0631 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0641\u0631\u0627\u063a<\/td><td>\u062a\u062f\u0647\u0648\u0631 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a<\/td><td>\u0627\u0633\u062a\u0628\u062f\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"safety-precautions\">\u0627\u062d\u062a\u064a\u0627\u0637\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629<\/h2>\n\n\n\n<p>\u062a\u062a\u0636\u0645\u0646 \u0635\u064a\u0627\u0646\u0629 VCB \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0632\u0646\u0629 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629.<\/p>\n\n\n\n<p><strong>\u0642\u0628\u0644 \u0628\u062f\u0621 \u0627\u0644\u0639\u0645\u0644<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0639\u0632\u0644<\/strong>: \u0627\u0633\u062a\u062e\u062f\u0645 \u0643\u0627\u0634\u0641 \u0627\u0644\u062c\u0647\u062f \u0639\u0644\u0649 \u062c\u0645\u064a\u0639 \u0627\u0644\u062f\u0648\u0627\u0626\u0631<\/li>\n\n\n\n<li><strong>\u0625\u0642\u0641\u0627\u0644 \u0627\u0644\u0642\u0641\u0644\/\u0633\u062d\u0628 \u0627\u0644\u0628\u0637\u0627\u0642\u0629<\/strong>: \u0645\u0646\u0639 \u0627\u0644\u062a\u0646\u0634\u064a\u0637 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0639\u0645\u0644<\/li>\n\n\n\n<li><strong>\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0632\u0646\u0629<\/strong>: \u0627\u0644\u0646\u0648\u0627\u0628\u0636 \u0648\u0627\u0644\u0645\u0643\u062b\u0641\u0627\u062a \u0648\u0627\u0644\u0645\u0631\u0627\u0643\u0645 \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a\u0629<\/li>\n\n\n\n<li><strong>\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0648\u0642\u0627\u064a\u0629 \u0645\u0646 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>: \u062d\u062a\u0649 \u0627\u0644\u0639\u0645\u0644 \u063a\u064a\u0631 \u0627\u0644\u0645\u0646\u0634\u0637 \u064a\u062a\u0637\u0644\u0628 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0648\u0642\u0627\u064a\u0629 \u0627\u0644\u0634\u062e\u0635\u064a\u0629 (\u0627\u0644\u062d\u062b\u060c \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0632\u0646\u0629)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a<\/strong>: \u0627\u0644\u0645\u0648\u0638\u0641\u0648\u0646 \u0627\u0644\u0645\u062f\u0631\u0628\u0648\u0646 \u0641\u0642\u0637\u060c \u0648\u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0644\u062a\u0635\u0627\u0631\u064a\u062d \u062d\u0633\u0628 NFPA 70E<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/strong>: \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u063a\u0644\u0642 \u0627\u0644\u0642\u0627\u0637\u0639\/\u064a\u062a\u0639\u0637\u0644 \u0628\u0642\u0648\u0629 \u0643\u0628\u064a\u0631\u0629 - \u0627\u0628\u0642 \u0628\u0639\u064a\u062f\u064b\u0627 \u0639\u0646 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u062a\u062d\u0631\u0643\u0629<\/li>\n\n\n\n<li><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/strong>: \u062a\u062e\u0644\u0642 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 (100-200 \u0623\u0645\u0628\u064a\u0631) \u0642\u0648\u0649 \u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0628\u0639\u062f \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0648\u0638\u064a\u0641\u064a<\/strong>: \u0631\u062d\u0644\u0629 \u0648\u0625\u063a\u0644\u0627\u0642 \u0639\u062f\u0629 \u0645\u0631\u0627\u062a \u0642\u0628\u0644 \u0627\u0644\u062a\u0646\u0634\u064a\u0637<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0625\u0639\u062f\u0627\u062f\u0627\u062a<\/strong>: \u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0645\u0631\u062d\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629\u060c \u0627\u0644\u062a\u0639\u0634\u064a\u0642<\/li>\n\n\n\n<li><strong>\u0648\u062b\u064a\u0642\u0629<\/strong>: \u0627\u0633\u062a\u0643\u0645\u0627\u0644 \u0633\u062c\u0644 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0642\u0628\u0644 \u0627\u0644\u0639\u0648\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u062e\u062f\u0645\u0629<\/li>\n<\/ol>\n\n\n\n<p>\u0644\u0644\u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0623\u0646\u0648\u0627\u0639 \u0645\u062d\u062f\u062f\u0629 \u0645\u0646 \u0645\u0631\u0643\u0628\u0627\u062a \u0627\u0644\u0643\u0631\u0628\u0648\u0646 \u0627\u0644\u0637\u0631\u0641\u064a \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a\u060c \u0631\u0627\u062c\u0639 \u0623\u062f\u0644\u0629 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0648\u0647\u0630\u0627&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/drawout-vcb-racking-safety-shutters-alignment-checks\/\">\u0642\u0627\u0626\u0645\u0629 \u0645\u0631\u0627\u062c\u0639\u0629 \u0623\u0631\u0641\u0641 VCB \u0627\u0644\u0645\u0633\u062d\u0648\u0628\u0629 \u0648\u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0639\u0637\u064a \u0635\u064a\u0627\u0646\u0629 VCB \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0644\u062c\u0627\u0647\u0632\u064a\u0629 \u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0646\u0627\u062f\u0631\u0629 \u0648\u0644\u0643\u0646 \u0627\u0644\u062d\u0631\u062c\u0629 - \u0641\u062d\u0648\u0635\u0627\u062a \u0628\u0635\u0631\u064a\u0629 \u0631\u0628\u0639 \u0633\u0646\u0648\u064a\u0629 \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\/\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0633\u0646\u0648\u064a\u0629 \u062a\u0636\u0645\u0646 \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629<\/li>\n\n\n\n<li>\u064a\u0639\u062f \u0642\u064a\u0627\u0633 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 (&lt;150 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631 \u0623\u0648\u0645) \u0648\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0648\u0642\u064a\u062a (\u0641\u064a \u062d\u062f\u0648\u062f \u00b1101 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a) \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0633\u0646\u0648\u064a\u0629 \u0625\u0644\u0632\u0627\u0645\u064a\u0629 \u062a\u062a\u0646\u0628\u0623 \u0628\u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0642\u0628\u0644 \u0623\u0634\u0647\u0631 \u0645\u0646 \u062d\u062f\u0648\u062b\u0647\u0627<\/li>\n\n\n\n<li>\u064a\u0624\u062b\u0631 \u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0628\u0634\u0643\u0644 \u0645\u0628\u0627\u0634\u0631 \u0639\u0644\u0649 \u0642\u062f\u0631\u0629 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 - \u0648\u0642\u062a \u0627\u0644\u0641\u062a\u062d &gt;10% \u0628\u0637\u064a\u0621 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0641\u0639\u0627\u0644\u064a\u0629 \u0625\u0637\u0641\u0627\u0621 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0642\u062f \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u0639\u062f\u0645 \u062a\u0637\u0627\u0628\u0642 \u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/li>\n\n\n\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (\u0627\u062e\u062a\u0628\u0627\u0631 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (\u062a\u062d\u0645\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0623\u0648 1000 \u0641\u0648\u0644\u062a \u0645\u064a\u062c\u0631 \u0639\u0628\u0631 \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0641\u062a\u0648\u062d\u0629) \u064a\u0643\u062a\u0634\u0641 \u062a\u062f\u0647\u0648\u0631 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0642\u0628\u0644 \u062d\u062f\u0648\u062b \u0639\u0637\u0644 \u0643\u0627\u0631\u062b\u064a \u0623\u062b\u0646\u0627\u0621 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0639\u0637\u0644<\/li>\n\n\n\n<li>\u064a\u062d\u0648\u0644 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u0633\u0627\u0626\u062f\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u0623\u0648\u0644\u064a\u0629 \u0625\u0644\u0649 \u0635\u064a\u0627\u0646\u0629 \u062a\u0646\u0628\u0624\u064a\u0629 - \u0627\u0633\u062a\u0642\u0631\u0627\u0621 \u0646\u0645\u0648 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u064a\u062a\u0646\u0628\u0623 \u0628\u0646\u0648\u0627\u0641\u0630 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0642\u0628\u0644 6-12 \u0634\u0647\u0631\u064b\u0627<\/li>\n\n\n\n<li>\u0627\u0644\u0641\u0648\u0627\u0635\u0644 \u0627\u0644\u0632\u0645\u0646\u064a\u0629 \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 (\u0643\u0644 2,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644) \u062a\u0643\u0645\u0644 \u0627\u0644\u062c\u062f\u0627\u0648\u0644 \u0627\u0644\u0632\u0645\u0646\u064a\u0629 \u0627\u0644\u0645\u0633\u062a\u0646\u062f\u0629 \u0625\u0644\u0649 \u0627\u0644\u0648\u0642\u062a \u0644\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u064a \u064a\u062a\u0645 \u062a\u0634\u063a\u064a\u0644\u0647\u0627 \u0628\u0634\u0643\u0644 \u0645\u062a\u0643\u0631\u0631 \u0645\u062b\u0644 \u0642\u0648\u0627\u0637\u0639 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0645\u0648\u0644\u062f\u0627\u062a \u0623\u0648 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u062d\u0648\u064a\u0644<\/li>\n\n\n\n<li>\u064a\u062a\u064a\u062d \u062a\u0648\u062b\u064a\u0642 \u0642\u0627\u0644\u0628 \u0627\u0644\u0633\u062c\u0644 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u062a\u0648\u062b\u064a\u0642 \u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u0623\u0633\u0637\u0648\u0644 \u0648\u062a\u062d\u0633\u064a\u0646\u0647 - \u062c\u0645\u0639 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0627\u0633\u0642 \u0639\u0628\u0631 \u0648\u062d\u062f\u0627\u062a \u0645\u0631\u0627\u0642\u0628\u0629 \u0623\u0633\u0637\u0648\u0644 \u0627\u0644\u0645\u0631\u0643\u0628\u0627\u062a \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a\u0629 \u0627\u0644\u0645\u062a\u0645\u0627\u062b\u0644\u0629 \u064a\u0643\u0634\u0641 \u0639\u0646 \u0623\u0646\u0645\u0627\u0637 \u063a\u064a\u0631 \u0645\u0631\u0626\u064a\u0629 \u0641\u064a \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0648\u062d\u062f\u0629 \u0627\u0644\u0648\u0627\u062d\u062f\u0629<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u0645\u0631\u062c\u0639 \u062e\u0627\u0631\u062c\u064a:<\/strong>&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">IEC 62271-106<\/a>&nbsp;- \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 IEC 62271-106 \u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629<\/h2>\n\n\n\n<p><strong>\u06331: \u0643\u0645 \u0645\u0631\u0629 \u064a\u062c\u0628 \u0623\u0646 \u0623\u062c\u0631\u064a \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0639\u0644\u0649 VCB\u061f<\/strong><br>\u062c: \u0633\u0646\u0648\u064a\u064b\u0627 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0642\u0648\u0627\u0637\u0639 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629\u060c \u0648\u0646\u0635\u0641 \u0633\u0646\u0648\u064a\u064b\u0627 \u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0645\u0648\u0644\u062f\u0627\u062a \u0623\u0648 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u062d\u0648\u064a\u0644 \u0630\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629 (&gt; 500 \u0639\u0645\u0644\u064a\u0629\/\u0633\u0646\u0629). \u0642\u0645 \u062f\u0627\u0626\u0645\u064b\u0627 \u0628\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0639\u062f \u0623\u064a \u0627\u0646\u0642\u0637\u0627\u0639 \u0639\u0637\u0644 &gt;50% \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629\u060c \u062d\u064a\u062b \u0623\u0646 \u0637\u0627\u0642\u0629 \u0642\u0648\u0633 \u0627\u0644\u0639\u0637\u0644 \u062a\u0633\u0631\u0639 \u0645\u0646 \u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633.<\/p>\n\n\n\n<p><strong>\u06332: \u0645\u0627 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 \u0635\u064a\u0627\u0646\u0629 VCB \u0648\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u061f<\/strong><br>\u062c: \u062a\u0631\u0643\u0632 \u0645\u0631\u0643\u0628\u0627\u062a \u0627\u0644\u062a\u0631\u0648\u0633 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0627\u0631\u062a\u062c\u0627\u062c \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0639\u0644\u0649 \u062c\u0627\u0647\u0632\u064a\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 (\u062f\u0642\u0629 \u0627\u0644\u062a\u0648\u0642\u064a\u062a\u060c \u0648\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0637\u0639\u0629) \u0628\u064a\u0646\u0645\u0627 \u062a\u0631\u0643\u0632 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a (\u062a\u062a\u0628\u0639 \u0627\u0644\u062a\u0622\u0643\u0644 \u0627\u0644\u062a\u0631\u0627\u0643\u0645\u064a). \u0648\u062a\u062a\u0637\u0644\u0628 \u0623\u062c\u0647\u0632\u0629 VCBs \u062a\u062d\u0644\u064a\u0644\u0627\u064b \u0623\u0643\u062b\u0631 \u062a\u0641\u0635\u064a\u0644\u0627\u064b \u0644\u0644\u062a\u0648\u0642\u064a\u062a\/\u0627\u0644\u0633\u0641\u0631 \u0644\u0623\u0646 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0639\u0637\u0644 \u064a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0633\u0631\u0639\u0629 \u0641\u0635\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u062f\u0642\u064a\u0642\u0629\u061b \u0628\u064a\u0646\u0645\u0627 \u062a\u0631\u0643\u0632 \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0623\u0643\u062b\u0631 \u0639\u0644\u0649 \u0627\u062a\u062c\u0627\u0647 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0628\u0633\u0628\u0628 \u0627\u0644\u062a\u0639\u0631\u0636 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0644\u0644\u0642\u0648\u0633.<\/p>\n\n\n\n<p><strong>\u06333: \u0647\u0644 \u064a\u0645\u0643\u0646\u0646\u064a \u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0628\u062f\u0648\u0646 \u0645\u0639\u062f\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f\u061f<\/strong><br>\u062c: \u0646\u0639\u0645- \u0627\u0633\u062a\u062e\u062f\u0645 1,000-2,500 \u0641\u0648\u0644\u062a \u0645\u064a\u062c\u064a\u0631 \u0639\u0628\u0631 \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0641\u062a\u0648\u062d\u0629 \u0643\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u062d\u0635 \u0645\u064a\u062f\u0627\u0646\u064a \u0645\u0646\u0627\u0633\u0628. \u064a\u0638\u0647\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u064a\u062f &gt; 100 \u0645\u064a\u063a\u0627 \u0623\u0648\u0645 \u0645\u0642\u0627\u0648\u0645\u0629. \u0647\u0630\u0647 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0623\u0642\u0644 \u062a\u062d\u062f\u064a\u062f\u064b\u0627 \u0645\u0646 \u0627\u062e\u062a\u0628\u0627\u0631 \u062a\u062d\u0645\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0648\u0644\u0643\u0646\u0647\u0627 \u0643\u0627\u0641\u064a\u0629 \u0644\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0627\u0644\u0631\u0648\u062a\u064a\u0646\u064a\u0629. \u0642\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0643\u0644 3-5 \u0633\u0646\u0648\u0627\u062a \u0623\u0648 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0646\u062a\u0627\u0626\u062c Megger \u0647\u0627\u0645\u0634\u064a\u0629.<\/p>\n\n\n\n<p><strong>\u06334: \u0645\u0627 \u0627\u0644\u0630\u064a \u064a\u062c\u0639\u0644 \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u064a\u0646\u062d\u0631\u0641 \u0639\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u0639 \u0645\u0631\u0648\u0631 \u0627\u0644\u0648\u0642\u062a\u061f<\/strong><br>\u062c: \u0627\u0644\u0623\u0633\u0628\u0627\u0628 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629: (1) \u062a\u0642\u0627\u062f\u0645 \u0627\u0644\u062a\u0634\u062d\u064a\u0645 - \u064a\u062c\u0641 \u0627\u0644\u0634\u062d\u0645 \u0623\u0648 \u064a\u0633\u064a\u0644\u060c \u0645\u0645\u0627 \u064a\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0627\u062d\u062a\u0643\u0627\u0643\u061b (2) \u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0632\u0646\u0628\u0631\u0643 - \u062a\u0641\u0642\u062f \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u0627\u062a \u0634\u062f\u0647\u0627 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 \u0622\u0644\u0627\u0641 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a\u061b (3) \u0627\u0644\u0628\u0644\u0649 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a - \u062a\u0633\u062a\u0637\u064a\u0644 \u0627\u0644\u062b\u0642\u0648\u0628 \u0627\u0644\u0645\u062d\u0648\u0631\u064a\u0629\u060c \u0648\u062a\u062a\u0622\u0643\u0644 \u062f\u0628\u0627\u0628\u064a\u0633 \u0627\u0644\u0648\u0635\u0644\u0629\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u062d\u062f\u0648\u062b \u0627\u0631\u062a\u062e\u0627\u0621\u061b (4) \u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0632\u0644\u0627\u062c - \u064a\u0642\u0644\u0644 \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0634\u064a\u0642. \u064a\u0639\u062f \u0627\u0644\u0627\u0646\u062c\u0631\u0627\u0641 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a \u0623\u0645\u0631\u064b\u0627 \u0637\u0628\u064a\u0639\u064a\u064b\u0627\u061b \u0623\u0645\u0627 \u0627\u0644\u062a\u063a\u064a\u0631\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u0629 \u0641\u062a\u0634\u064a\u0631 \u0625\u0644\u0649 \u0641\u0634\u0644 \u0645\u0643\u0648\u0646 \u0645\u0639\u064a\u0646.<\/p>\n\n\n\n<p><strong>\u06335: \u0643\u064a\u0641 \u0623\u0639\u0631\u0641 \u0645\u062a\u0649 \u064a\u062c\u0628 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0642\u0627\u0628\u0644 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0628\u0627\u0644\u0643\u0627\u0645\u0644\u061f<\/strong><br>\u062c: \u0625\u0630\u0627 \u062a\u062c\u0627\u0648\u0632\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u062d\u062f \u0627\u0644\u062e\u062f\u0645\u0629 (\u0639\u0627\u062f\u0629\u064b 150 \u03a9) \u0623\u0648 \u0625\u0630\u0627 \u062a\u0639\u0637\u0644\u062a \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u064a\u062c\u0628 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0628\u0627\u0644\u0643\u0627\u0645\u0644 - \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0648\u063a\u0644\u0627\u0641 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0639\u0628\u0627\u0631\u0629 \u0639\u0646 \u0648\u062d\u062f\u0629 \u0645\u062d\u0643\u0645\u0629 \u0627\u0644\u063a\u0644\u0642 \u0644\u0627 \u064a\u0645\u0643\u0646 \u0625\u0635\u0644\u0627\u062d\u0647\u0627 \u0645\u064a\u062f\u0627\u0646\u064a\u064b\u0627. \u0627\u0644\u062a\u0643\u0644\u0641\u0629: $300-$500 \u0644\u0643\u0644 \u0642\u0627\u0637\u0639 \u062d\u0633\u0628 \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u062c\u0647\u062f\/\u0627\u0644\u062a\u064a\u0627\u0631. \u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644: \u0645\u0646 2-6 \u0633\u0627\u0639\u0627\u062a \u0644\u0643\u0644 \u0642\u0627\u0637\u0639 \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621.<\/p>\n\n\n\n<p><strong>\u0633 6: \u0647\u0644 \u064a\u062c\u0628 \u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0641\u0635\u0644\u064a\u0629 \u0648\u0627\u0644\u0633\u0646\u0648\u064a\u0629 \u0628\u0648\u0627\u0633\u0637\u0629 \u0646\u0641\u0633 \u0627\u0644\u0645\u0648\u0638\u0641\u064a\u0646\u061f<\/strong><br>\u062c: \u064a\u0645\u0643\u0646 \u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0641\u0635\u0644\u064a\u0629 \u0628\u0648\u0627\u0633\u0637\u0629 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u064a \u0627\u0644\u0645\u0646\u0634\u0623\u0629 \u0627\u0644\u0645\u0637\u0644\u0639\u064a\u0646 \u0639\u0644\u0649 \u0627\u0644\u0645\u0639\u062f\u0627\u062a. \u0648\u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0633\u0646\u0648\u064a \u0645\u0639\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062a\u062e\u0635\u0635\u0629 (\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0623\u0648\u0645\u062a\u0631 \u0627\u0644\u062f\u0642\u064a\u0642\u060c \u0648\u0645\u062d\u0644\u0644 \u0627\u0644\u062a\u0648\u0642\u064a\u062a\u060c \u0648\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a) \u0648\u0627\u0644\u062a\u062f\u0631\u064a\u0628 \u0639\u0644\u0649 \u062a\u0641\u0633\u064a\u0631 \u0627\u0644\u0646\u062a\u0627\u0626\u062c\u060c \u0648\u0639\u0627\u062f\u0629 \u0645\u0627 \u064a\u0642\u0648\u0645 \u0628\u0647\u0627 \u0641\u0646\u064a\u0648 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0648\u0646 \u0623\u0648 \u0627\u0644\u0645\u062a\u062e\u0635\u0635\u0648\u0646 \u0627\u0644\u0645\u062a\u0639\u0627\u0642\u062f \u0645\u0639\u0647\u0645.<\/p>\n\n\n\n<p><strong>\u06337: \u0643\u064a\u0641 \u064a\u0624\u062b\u0631 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0639\u0644\u0649 \u0641\u062a\u0631\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u061f<\/strong><br>\u062c: \u064a\u0633\u0628\u0628 \u0643\u0644 \u0627\u0646\u0642\u0637\u0627\u0639 \u0644\u0644\u062e\u0637\u0623 \u062a\u0622\u0643\u0644\u064b\u0627 \u0643\u0628\u064a\u0631\u064b\u0627 \u0641\u064a \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0625\u062c\u0647\u0627\u062f\u064b\u0627 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u064b\u0627. \u0642\u0645 \u0628\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0648\u0642\u064a\u062a \u0628\u0639\u062f \u0623\u064a \u0627\u0646\u0642\u0637\u0627\u0639 \u0639\u0637\u0644 &gt;50% \u0645\u0646 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0642\u062f\u0631. \u0642\u062f \u062a\u0633\u062a\u0647\u0644\u0643 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0645\u062a\u0639\u062f\u062f\u0629 \u0633\u0646\u0648\u0627\u062a \u0645\u0646 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0627\u0644\u0639\u0627\u062f\u064a \u0641\u064a \u062b\u0648\u0627\u0646\u064d - \u0627\u0636\u0628\u0637 \u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0648\u0641\u0642\u064b\u0627 \u0644\u0630\u0644\u0643 \u0628\u0646\u0627\u0621\u064b \u0639\u0644\u0649 \u062a\u0627\u0631\u064a\u062e \u0627\u0644\u0639\u0637\u0644\u060c \u0648\u0644\u064a\u0633 \u0641\u0642\u0637 \u0639\u062f\u062f \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a.<\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Vacuum circuit breakers fail in predictable ways. Contact erosion from arc energy, timing drift from mechanism wear, insulation degradation from moisture\u2014these deterioration modes announce themselves through measurable indicators months before catastrophic failure. Unlike contactors that switch loads thousands of times annually, VCBs interrupt faults occasionally but must perform flawlessly when called. A single failure [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2538,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2537","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=2537"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2537\/revisions"}],"predecessor-version":[{"id":3552,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2537\/revisions\/3552"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/2538"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=2537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=2537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=2537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}