{"id":2582,"date":"2026-01-13T05:51:39","date_gmt":"2026-01-13T05:51:39","guid":{"rendered":"https:\/\/xbrele.com\/?p=2582"},"modified":"2026-04-07T14:49:43","modified_gmt":"2026-04-07T14:49:43","slug":"mv-switchgear-manufacturers-mining","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/mv-switchgear-manufacturers-mining\/","title":{"rendered":"\u0643\u0628\u0627\u0631 \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 MV \u0644\u0644\u062a\u0639\u062f\u064a\u0646: \u0627\u0644\u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0645\u062e\u062a\u0635\u0631\u0629 \u0644\u0644\u0645\u0634\u062a\u0631\u064a\u0646 + \u0633\u0628\u0628 \u0623\u0647\u0645\u064a\u062a\u0647\u0627"},"content":{"rendered":"<p>\u062a\u062f\u0645\u0631 \u0628\u064a\u0626\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0646\u062c\u0648 \u0641\u064a \u0623\u0645\u0627\u0643\u0646 \u0623\u062e\u0631\u0649. \u0627\u062e\u062a\u0631\u0627\u0642 \u0627\u0644\u063a\u0628\u0627\u0631 \u064a\u0647\u0632\u0645 \u062a\u0635\u0646\u064a\u0641\u0627\u062a IP \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0641\u064a \u063a\u0636\u0648\u0646 \u0623\u0634\u0647\u0631. \u064a\u0624\u062f\u064a \u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632 \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646 \u0627\u0644\u062a\u0641\u062c\u064a\u0631 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062b\u0642\u064a\u0644\u0629 \u0625\u0644\u0649 \u062a\u0634\u0642\u0642 \u0627\u0644\u0639\u0648\u0627\u0632\u0644 \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a\u0629 \u0627\u0644\u0645\u0635\u0645\u0645\u0629 \u0644\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062b\u0627\u0628\u062a\u0629. \u064a\u0642\u0644\u0644 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0645\u0643\u0634\u0648\u0641\u0629 \u0648\u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0645\u0646 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u0647\u0648\u0627\u0621 \u0628\u0645\u0642\u062f\u0627\u0631 10-20%. \u062a\u062a\u0623\u0631\u062c\u062d \u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0645\u0646 -30 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u0633\u0637\u062d \u0625\u0644\u0649 +45 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0645\u0645\u0627 \u064a\u0636\u063a\u0637 \u0639\u0644\u0649 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u0635\u0645\u0645\u0629 \u0644\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u062e\u0627\u0636\u0639\u0629 \u0644\u0644\u062a\u062d\u0643\u0645.<\/p>\n\n\n\n<p>\u0644\u0627 \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062d\u062f\u062f \u0627\u062e\u062a\u064a\u0627\u0631 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u062a\u0648\u0633\u0637\u0629 \u0627\u0644\u062c\u0647\u062f \u0644\u0644\u062a\u0639\u062f\u064a\u0646 \u0628\u0628\u0633\u0627\u0637\u0629 \u062a\u0635\u0646\u064a\u0641\u0627\u062a IEC \u0648\u0623\u0642\u0644 \u0639\u0631\u0636 \u0633\u0639\u0631. \u0625\u0646 \u0644\u0648\u062d\u0629 12 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0627\u0644\u0645\u0635\u0646\u0641\u0629 IP54\u060c \u0627\u0644\u062a\u064a \u062a\u0645 \u0627\u062e\u062a\u0628\u0627\u0631\u0647\u0627 \u0639\u0646\u062f \u0645\u0633\u062a\u0648\u0649 \u0633\u0637\u062d \u0627\u0644\u0628\u062d\u0631\u060c \u0648\u0627\u0644\u062a\u064a \u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u0644\u0627 \u062a\u0634\u0648\u0628\u0647 \u0634\u0627\u0626\u0628\u0629 \u0641\u064a \u0645\u062d\u0637\u0629 \u0641\u0631\u0639\u064a\u0629 \u0646\u0638\u064a\u0641\u0629 \u0633\u062a\u0641\u0634\u0644 \u0628\u0634\u0643\u0644 \u0643\u0627\u0631\u062b\u064a \u0639\u0646\u062f \u062a\u0631\u0643\u064a\u0628\u0647\u0627 \u0641\u064a \u0645\u062d\u0637\u0629 \u062a\u0643\u0633\u064a\u0631 \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 3500 \u0645\u062a\u0631 \u0645\u0639 \u063a\u0628\u0627\u0631 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0627 \u0627\u0644\u0645\u062d\u0645\u0648\u0644 \u062c\u0648\u0627\u064b \u0648\u062a\u062d\u0645\u064a\u0644 \u0627\u0644\u0635\u062f\u0645\u0627\u062a \u0645\u0646 \u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u062e\u0627\u0645.<\/p>\n\n\n\n<p>\u064a\u0642\u0648\u0645 \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0627\u0644\u0630\u064a\u0646 \u064a\u0641\u0647\u0645\u0648\u0646 \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0628\u0647\u0646\u062f\u0633\u0629 \u062d\u0644\u0648\u0644 \u062a\u062a\u062c\u0627\u0648\u0632 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c: \u0627\u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u062d\u0643\u0645\u0629 \u0627\u0644\u063a\u0644\u0642 \u0627\u0644\u0645\u062d\u0635\u0646\u0629 \u0636\u062f \u062f\u062e\u0648\u0644 \u0627\u0644\u063a\u0628\u0627\u0631\u060c \u0648\u062f\u0639\u0627\u0645\u0627\u062a \u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0645\u0642\u0648\u0627\u0629 \u0628\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a\u060c \u0648\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0645\u0635\u062d\u062d \u0644\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u060c \u0648\u0627\u0644\u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u062a\u064a\u062d \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0633\u0631\u064a\u0639 \u062e\u0644\u0627\u0644 \u0646\u0648\u0627\u0641\u0630 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0636\u064a\u0642\u0629 \u0627\u0644\u062a\u064a \u062a\u0633\u0645\u062d \u0628\u0647\u0627 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646.<\/p>\n\n\n\n<p>\u064a\u062d\u062f\u062f \u0647\u0630\u0627 \u0627\u0644\u062f\u0644\u064a\u0644 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u062a\u064a \u0644\u062f\u064a\u0647\u0627 \u0645\u062d\u0627\u0641\u0638 \u062a\u0639\u062f\u064a\u0646 \u0645\u062b\u0628\u062a\u0629\u060c \u0648\u064a\u0634\u0631\u062d \u0645\u0627 \u064a\u0645\u064a\u0632 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0639\u0646 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629\u060c \u0648\u064a\u0648\u0641\u0631 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u064a \u062a\u062d\u062a\u0627\u062c\u0647\u0627 \u0641\u0631\u0642 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a \u0639\u0646\u062f \u062a\u062d\u062f\u064a\u062f \u0623\u0646\u0638\u0645\u0629 \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0633\u0637\u062d\u064a\u0629 \u0648\u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629 \u0641\u064a\u00a0<a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\">\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0641\u064a \u062c\u0645\u064a\u0639 \u0623\u0646\u062d\u0627\u0621 \u0627\u0644\u0639\u0627\u0644\u0645<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-mining-switchgear-requirements-differ\">\u0644\u0645\u0627\u0630\u0627 \u062a\u062e\u062a\u0644\u0641 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/h2>\n\n\n\n<p>\u062a\u0641\u062a\u0631\u0636 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0648\u062c\u0648\u062f \u0628\u064a\u0626\u0627\u062a \u0645\u062d\u0643\u0648\u0645\u0629. \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u064a\u062a\u062d\u062f\u0649 \u0643\u0644 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u0627\u062a. \u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u064a\u0629 #5T1T5T1T1T5T5T<\/p>\n\n\n\n<p><strong>\u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u062a\u0644\u0648\u062b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0627 \u0627\u0644\u0645\u062d\u0645\u0648\u0644\u0629 \u0641\u064a \u0627\u0644\u0647\u0648\u0627\u0621\u060c \u0648\u063a\u0628\u0627\u0631 \u0627\u0644\u0641\u062d\u0645\u060c \u0648\u0627\u0644\u062c\u0633\u064a\u0645\u0627\u062a \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629<\/li>\n\n\n\n<li>\u062d\u0627\u0648\u064a\u0627\u062a IP54 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u062a\u0641\u0634\u0644 - \u0627\u0644\u063a\u0628\u0627\u0631 \u064a\u062e\u062a\u0631\u0642 \u0645\u062f\u0627\u062e\u0644 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0648\u0645\u0633\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0647\u0648\u064a\u0629<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: IP65\/IP66 \u0643\u062d\u062f \u0623\u062f\u0646\u0649\u060c \u0648\u0628\u0637\u0627\u0646\u0627\u062a \u0645\u062d\u0643\u0645\u0629 \u0627\u0644\u063a\u0644\u0642\u060c \u0648\u062a\u0647\u0648\u064a\u0629 \u0628\u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0625\u064a\u062c\u0627\u0628\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a \u0648\u0627\u0644\u0635\u062f\u0645\u0627\u062a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a \u0627\u0644\u062a\u0641\u062c\u064a\u0631: 5-15 \u0647\u0631\u062a\u0632\u060c \u062a\u0633\u0627\u0631\u0639 0.2-0.8 \u062c\u0645<\/li>\n\n\n\n<li>\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a: \u0627\u0644\u0646\u0627\u0642\u0644\u0627\u062a\u060c \u0648\u0627\u0644\u0643\u0633\u0627\u0631\u0627\u062a\u060c \u0648\u0627\u0644\u0643\u0633\u0627\u0631\u0627\u062a\u060c \u0648\u0627\u0644\u0645\u0637\u0627\u062d\u0646 \u062a\u062e\u0644\u0642 \u0627\u0647\u062a\u0632\u0627\u0632\u064b\u0627 \u0645\u0633\u062a\u0645\u0631\u064b\u0627<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u062a\u0631\u0643\u064a\u0628 \u0645\u0639\u0632\u0632\u060c \u0648\u0645\u0643\u0648\u0646\u0627\u062a \u0645\u062e\u0645\u062f\u0629 \u0644\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u060c \u0648\u0645\u0643\u0648\u0646\u0627\u062a \u0645\u062e\u0645\u062f\u0629 \u0644\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u060c \u0648\u0623\u062c\u0647\u0632\u0629 \u062a\u0639\u0634\u064a\u0642 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0644\u0627 \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0645\u062d\u0627\u0630\u0627\u0629 \u062f\u0642\u064a\u0642\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u062a\u0623\u062b\u064a\u0631\u0627\u062a \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0639\u0645\u0644 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 2,000-4,500 \u0645\u062a\u0631<\/li>\n\n\n\n<li>\u0627\u0646\u062e\u0641\u0627\u0636 \u0643\u062b\u0627\u0641\u0629 \u0627\u0644\u0647\u0648\u0627\u0621 \u2192 \u0627\u0646\u062e\u0641\u0627\u0636 \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062a\u0628\u0631\u064a\u062f<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u0645\u0639\u0627\u0645\u0644\u0627\u062a \u062a\u0635\u062d\u064a\u062d \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 (\u0636\u0631\u0628 BIL \u0641\u064a 1.10-1.25)\u060c \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0643\u0628\u064a\u0631\u0629 \u0627\u0644\u062d\u062c\u0645\u060c \u0648\u0627\u0644\u0627\u0633\u062a\u062b\u0646\u0627\u0621\u0627\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0642\u0635\u0648\u0649<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0633\u0637\u062d: -40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u062a\u062d\u062a \u0627\u0644\u0635\u0641\u0631 (\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0642\u0637\u0628 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\/\u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0645\u0631\u062a\u0641\u0639\u0629) \u0625\u0644\u0649 +50 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 (\u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0641\u062a\u0648\u062d\u0629)<\/li>\n\n\n\n<li>\u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0645\u0646 +30 \u0625\u0644\u0649 +45 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0645\u0639 \u0631\u0637\u0648\u0628\u0629 90%+<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u0633\u062e\u0627\u0646\u0627\u062a\/\u0623\u062c\u0647\u0632\u0629 \u062a\u0631\u0645\u0648\u0633\u062a\u0627\u062a \u0644\u0644\u0623\u0645\u0627\u0643\u0646 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629\u060c \u0648\u062a\u0628\u0631\u064a\u062f \u0643\u0628\u064a\u0631 \u0627\u0644\u062d\u062c\u0645 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636\u060c \u0648\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u062a\u0643\u062b\u064a\u0641<\/li>\n<\/ul>\n\n\n\n<p><strong>\u062c\u0648 \u0645\u062a\u0622\u0643\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0635\u0631\u0641 \u0627\u0644\u062d\u0645\u0636\u064a (\u0627\u0644\u062e\u0627\u0645\u0627\u062a \u0627\u0644\u062d\u0627\u0645\u0644\u0629 \u0644\u0644\u0643\u0628\u0631\u064a\u062a)<\/li>\n\n\n\n<li>\u0631\u0630\u0627\u0630 \u0627\u0644\u0645\u0644\u062d (\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0633\u0627\u062d\u0644\u064a\u0629)<\/li>\n\n\n\n<li>\u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0643\u064a\u0645\u064a\u0627\u0626\u064a\u0629 (\u0627\u0644\u062a\u0639\u0648\u064a\u0645\u060c \u0627\u0644\u0646\u0636\u0651)<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u062d\u0627\u0648\u064a\u0627\u062a \u063a\u064a\u0631 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0635\u062f\u0623\/\u0645\u063a\u0644\u0641\u0646\u0629 \u0648\u0637\u0644\u0627\u0621 \u0645\u0637\u0627\u0628\u0642 \u0644\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0627\u062a<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-mining-environment-challenges.webp\" alt=\"\u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0648\u0627\u062c\u0647 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0641\u064a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0648\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0642\u0635\u0648\u0649\" class=\"wp-image-2584\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-mining-environment-challenges.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-mining-environment-challenges-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-mining-environment-challenges-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-mining-environment-challenges-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u062a\u0641\u0631\u0636 \u0628\u064a\u0626\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0636\u063a\u0648\u0637\u064b\u0627 \u0645\u0634\u062a\u0631\u0643\u0629 - \u062f\u062e\u0648\u0644 \u0627\u0644\u063a\u0628\u0627\u0631\u060c \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u060c \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u060c \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u060c \u0648\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0642\u0635\u0648\u0649\u060c \u0648\u0627\u0644\u062a\u0622\u0643\u0644 - \u0644\u0645 \u064a\u062a\u0645 \u062a\u0635\u0645\u064a\u0645 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0644\u062a\u062d\u0645\u0644\u0647\u0627.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operational-requirements\">\u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0633\u0631\u064a\u0639\u0629 \u0644\u0644\u0623\u0639\u0637\u0627\u0644<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0623\u0641\u0631\u0627\u062f \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 - \u064a\u0639\u0645\u0644 \u0639\u0645\u0627\u0644 \u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0641\u064a \u0627\u0644\u0623\u0645\u0627\u0643\u0646 \u0627\u0644\u0636\u064a\u0642\u0629<\/li>\n\n\n\n<li>\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 - \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0645\u062d\u0631\u0643 \u0637\u0627\u062d\u0648\u0646\u0629 \u0628\u0642\u0648\u0629 4,000 \u062d\u0635\u0627\u0646 \u064a\u0643\u0644\u0641 \u0623\u0633\u0627\u0628\u064a\u0639 \u0645\u0646 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u062d\u0645\u0627\u064a\u0629 \u0633\u0631\u064a\u0639\u0629 \u0627\u0644\u0645\u0641\u0639\u0648\u0644 (\u064a\u0641\u0636\u0644 VCB \u0639\u0644\u0649 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a)\u060c \u0648\u062a\u0646\u0633\u064a\u0642 \u0627\u0646\u062a\u0642\u0627\u0626\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0643\u0627\u0644\u064a\u0641 \u0648\u0642\u062a \u0627\u0644\u062a\u0648\u0642\u0641 \u0639\u0646 \u0627\u0644\u0639\u0645\u0644 $50,000-500,000\/\u0633\u0627\u0639\u0629 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629<\/li>\n\n\n\n<li>\u062a\u0642\u0627\u0633 \u0646\u0648\u0627\u0641\u0630 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0628\u0627\u0644\u0633\u0627\u0639\u0627\u062a \u0648\u0644\u064a\u0633 \u0628\u0627\u0644\u0623\u064a\u0627\u0645<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u062a\u0635\u0627\u0645\u064a\u0645 \u0645\u0639\u064a\u0627\u0631\u064a\u0629\/\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628\u060c \u0648\u062a\u0648\u0627\u0641\u0631 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u0645\u062d\u0644\u064a\u0629\u060c \u0648\u062f\u0639\u0645 \u0627\u0644\u0645\u0635\u0646\u0639 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 \u0627\u0644\u0633\u0627\u0639\u0629 \u0637\u0648\u0627\u0644 \u0623\u064a\u0627\u0645 \u0627\u0644\u0623\u0633\u0628\u0648\u0639<\/li>\n<\/ul>\n\n\n\n<p><strong>\u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062c\u0631 \u0644\u0644\u0633\u062d\u0628\u060c \u0648\u0627\u0644\u0645\u062c\u0627\u0631\u0641\u060c \u0648\u0639\u0645\u0627\u0644\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u0629<\/li>\n\n\n\n<li>\u0627\u062a\u0635\u0627\u0644\u0627\u062a\/\u0627\u0646\u0641\u0635\u0627\u0644 \u0645\u062a\u0643\u0631\u0631<\/li>\n\n\n\n<li>\u064a\u062a\u0637\u0644\u0628: \u0642\u062f\u0631\u0629 \u062a\u062d\u0645\u0644 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0639\u0627\u0644\u064a\u0629\u00a0<a href=\"https:\/\/xbrele.com\/ar\/vacuum-contactor\/\">\u0645\u0648\u0635\u0644 \u0641\u0631\u0627\u063a<\/a>\u00a0(\u0623\u0643\u062b\u0631 \u0645\u0646 100,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644)\u060c \u0639\u0645\u0644\u064a\u0627\u062a \u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0642\u0648\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"top-manufacturers-for-mining-applications\">\u0623\u0641\u0636\u0644 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-manufacturer-positioning-matrix-1.webp\" alt=\"\u0645\u0635\u0641\u0648\u0641\u0629 \u062a\u062d\u062f\u064a\u062f \u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u062d\u0633\u0628 \u0627\u0644\u0633\u0639\u0631 \u0648\u062e\u0628\u0631\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646\" class=\"wp-image-2585\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-manufacturer-positioning-matrix-1.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-manufacturer-positioning-matrix-1-300x300.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-manufacturer-positioning-matrix-1-150x150.webp 150w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-manufacturer-positioning-matrix-1-768x768.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-manufacturer-positioning-matrix-1-12x12.webp 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0635\u0641\u0648\u0641\u0629 \u062a\u062d\u062f\u064a\u062f \u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u062a\u064a \u062a\u0642\u0627\u0631\u0646 \u0628\u064a\u0646 \u062e\u0628\u0631\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u0646\u0633\u0628\u064a\u0629 \u0644\u0645\u0648\u0631\u062f\u064a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637.\r<br><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-abb-switzerlandglobal\">1. ABB (\u0633\u0648\u064a\u0633\u0631\u0627\/\u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 MV MNS \u0648 ZS1 (VCBs \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628)<\/li>\n\n\n\n<li>\u0623\u0646\u0638\u0645\u0629 \u062a\u0642\u0644\u064a\u0644 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a PCS100<\/li>\n\n\n\n<li>\u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0639\u062f\u064a\u0646 (\u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0623\u0631\u0636\u064a REF615)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062a\u0623\u0647\u064a\u0644 \u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a<\/strong>: \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0645\u0635\u0646\u0641\u0629 \u062d\u0633\u0628 \u0627\u0644\u0632\u0644\u0627\u0632\u0644 (IEEE 693) \u062a\u062a\u0643\u064a\u0641 \u0645\u0639 \u0623\u062d\u0645\u0627\u0644 \u0635\u062f\u0645\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/li>\n\n\n\n<li><strong>\u062a\u062c\u0631\u0628\u0629 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a<\/strong>: \u062a\u0648\u0636\u062d \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0641\u064a \u0625\u0644 \u062a\u064a\u0646\u064a\u0646\u062a\u064a (\u0634\u064a\u0644\u064a\u060c 3,000 \u0645\u062a\u0631) \u0648\u064a\u0627\u0646\u0627\u0643\u0648\u0634\u0627 (\u0628\u064a\u0631\u0648\u060c 4,000 \u0645\u062a\u0631) \u0627\u0644\u0623\u062f\u0627\u0621 \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0639\u0627\u0644\u064a\u0629<\/li>\n\n\n\n<li><strong>\u0634\u0628\u0643\u0629 \u0627\u0644\u062e\u062f\u0645\u0627\u062a \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629<\/strong>:: \u062f\u0639\u0645 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 \u0627\u0644\u0633\u0627\u0639\u0629 \u0637\u0648\u0627\u0644 \u0623\u064a\u0627\u0645 \u0627\u0644\u0623\u0633\u0628\u0648\u0639\u060c \u0648\u0645\u062e\u0632\u0648\u0646 \u0645\u062d\u0644\u064a \u0641\u064a \u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/li>\n\n\n\n<li><strong>\u062a\u062e\u0641\u064a\u0641 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>: \u062a\u0642\u0644\u0644 \u0623\u0646\u0638\u0645\u0629 PCS100 \u0645\u0646 \u0637\u0627\u0642\u0629 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a 80-90%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0633\u0637\u062d\u064a\u0629 \u0627\u0644\u0643\u0628\u064a\u0631\u0629\u060c \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0623\u0633\u0639\u0627\u0631 \u0645\u0645\u062a\u0627\u0632\u0629 (20-30% \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0645\u062a\u0648\u0633\u0637)\u060c \u0648\u0645\u0647\u0644 \u0632\u0645\u0646\u064a\u0629 \u0637\u0648\u064a\u0644\u0629 \u0644\u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u0645\u062e\u0635\u0635\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0627\u0631\u0632\u0629<\/strong>: \u0625\u0633\u0643\u0648\u0646\u062f\u064a\u062f\u0627 (\u0634\u064a\u0644\u064a)\u060c \u0627\u0644\u0633\u062f \u0627\u0644\u0623\u0648\u0644\u0645\u0628\u064a (\u0623\u0633\u062a\u0631\u0627\u0644\u064a\u0627)\u060c \u0623\u0648\u064a\u0648 \u062a\u0648\u0644\u063a\u0648\u064a (\u0645\u0646\u063a\u0648\u0644\u064a\u0627)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-schneider-electric-franceglobal\">2. \u0634\u0646\u0627\u064a\u062f\u0631 \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0641\u0631\u0646\u0633\u0627\/\u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062f\u0645\u062c\u0629 SM6\u060c RM6 (SF6\/\u0647\u062c\u064a\u0646 \u0627\u0644\u062a\u0641\u0631\u064a\u063a)<\/li>\n\n\n\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0628\u0631\u064a\u0645\u0633\u064a\u062a\u060c \u0623\u0648\u0643\u064a\u0646 MV \u0644\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629<\/li>\n\n\n\n<li>\u0645\u0646\u0635\u0629 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0631\u0642\u0645\u064a\u0629 EcoStruxure<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0628\u0635\u0645\u0629 \u0645\u062f\u0645\u062c\u0629<\/strong>: \u062a\u0635\u0645\u064a\u0645\u0627\u062a RM6 \u0627\u0644\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u063a\u0627\u0632 \u062a\u0642\u0644\u0644 \u0645\u0646 \u0645\u0633\u0627\u062d\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 40-60% \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u0647\u0648\u0627\u0621<\/li>\n\n\n\n<li><strong>\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u0629 \u0627\u0644\u0642\u0627\u0633\u064a\u0629<\/strong>: \u0625\u0635\u062f\u0627\u0631\u0627\u062a IP67 \u0644\u0644\u0623\u062c\u0648\u0627\u0621 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0648\u0627\u0644\u0623\u062c\u0648\u0627\u0621 \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u0633\u0628\u0628\u0629 \u0644\u0644\u062a\u0622\u0643\u0644<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629<\/strong>: \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0627\u0633\u062a\u0634\u0639\u0627\u0631 \u0627\u0644\u062a\u064a \u062a\u062f\u0639\u0645 \u0625\u0646\u062a\u0631\u0646\u062a \u0627\u0644\u0623\u0634\u064a\u0627\u0621 \u062a\u062a\u0639\u0642\u0628 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a<\/li>\n\n\n\n<li><strong>\u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629<\/strong>: \u062a\u062a\u064a\u062d \u0627\u0644\u0623\u062f\u0631\u0627\u062c\/\u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0648\u062d\u062f\u0629 \u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0627\u0644\u0633\u0631\u064a\u0639<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0623\u0644\u0648\u0627\u062d \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 (\u0645\u062d\u062f\u0648\u062f\u0629 \u0627\u0644\u0645\u0633\u0627\u062d\u0629)\u060c \u0648\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0646\u0627\u0626\u064a\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0645\u062e\u0627\u0648\u0641 \u0628\u064a\u0626\u064a\u0629 \u062a\u062a\u0639\u0644\u0642 \u0628\u0640 SF6 (\u0639\u0644\u0649 \u0627\u0644\u0631\u063a\u0645 \u0645\u0646 \u0623\u0646 \u0627\u0644\u062a\u0635\u0627\u0645\u064a\u0645 \u0627\u0644\u062d\u062f\u064a\u062b\u0629 \u062a\u0642\u0644\u0644 \u0645\u0646 \u0627\u0644\u062a\u0633\u0631\u0628 \u0625\u0644\u0649 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649)\u060c \u0648\u062a\u062d\u062f \u0627\u0644\u062a\u0635\u0627\u0645\u064a\u0645 \u0627\u0644\u0645\u0633\u062c\u0644\u0629 \u0627\u0644\u0645\u0644\u0643\u064a\u0629 \u0645\u0646 \u062e\u062f\u0645\u0629 \u0627\u0644\u0637\u0631\u0641 \u0627\u0644\u062b\u0627\u0644\u062b<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0627\u0631\u0632\u0629<\/strong>: \u063a\u0631\u0627\u0633\u0628\u0631\u063a (\u0625\u0646\u062f\u0648\u0646\u064a\u0633\u064a\u0627)\u060c \u0648\u0633\u064a\u0634\u0646 (\u062c\u0646\u0648\u0628 \u0623\u0641\u0631\u064a\u0642\u064a\u0627)\u060c \u0648\u0628\u0648\u062f\u064a\u0646\u063a\u062a\u0648\u0646 (\u0623\u0633\u062a\u0631\u0627\u0644\u064a\u0627)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-siemens-energy-germanyglobal\">3. \u0634\u0631\u0643\u0629 \u0633\u064a\u0645\u0646\u0632 \u0644\u0644\u0637\u0627\u0642\u0629 (\u0623\u0644\u0645\u0627\u0646\u064a\u0627\/\u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 Simosec\/Nxair MV (\u0639\u0627\u0632\u0644 \u0647\u0648\u0627\u0621 \u0646\u0638\u064a\u0641\u060c \u062e\u0627\u0644\u064a \u0645\u0646 SF6)<\/li>\n\n\n\n<li>\u0645\u0631\u0627\u0643\u0632 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a SIVACON 8PT<\/li>\n\n\n\n<li>\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629\/\u0627\u0644\u062a\u062d\u0643\u0645 SICAM<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062a\u0642\u0646\u064a\u0629 \u062e\u0627\u0644\u064a\u0629 \u0645\u0646 \u0633\u0627\u062f\u0633 \u0641\u0644\u0648\u0631\u064a\u062f \u0627\u0644\u0643\u0628\u0631\u064a\u062a 6<\/strong>: \u0639\u0632\u0644 \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0646\u0638\u064a\u0641 \u064a\u0632\u064a\u0644 \u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0627\u0644\u0628\u064a\u0626\u064a<\/li>\n\n\n\n<li><strong>\u062a\u0643\u0627\u0645\u0644 \u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>: \u062a\u062a\u0643\u0627\u0645\u0644 \u0623\u0646\u0638\u0645\u0629 SICAM \u0645\u0639 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0622\u0644\u064a \u0641\u064a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0622\u0644\u064a \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u062c\u0645\/ \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0622\u0644\u064a \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u062c\u0645<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0645\u062a\u0627\u0646\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: \u0647\u064a\u0643\u0644 \u0634\u062f\u064a\u062f \u0627\u0644\u062a\u062d\u0645\u0644\u060c \u062d\u0627\u0648\u064a\u0627\u062a \u0645\u0644\u062d\u0648\u0645\u0629 (\u063a\u064a\u0631 \u0645\u062b\u0628\u062a\u0629 \u0628\u0645\u0633\u0627\u0645\u064a\u0631)<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629<\/strong>: \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062a\u0642\u062f\u0645\u0629 \u0644\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0645\u062d\u064a\u0637<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0627\u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u062d\u0633\u0627\u0633\u0629 \u0628\u064a\u0626\u064a\u064b\u0627\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u0645\u062a\u0643\u0627\u0645\u0644\u0629\u060c \u0648\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u0645\u062a\u0643\u0627\u0645\u0644\u0629\u060c \u0648\u0627\u0644\u0645\u0648\u0627\u0642\u0639 \u0630\u0627\u062a \u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0627\u0644\u0641\u0626\u0629 \u0627\u0644\u0623\u0639\u0644\u0649 \u062a\u0643\u0644\u0641\u0629\u060c \u0648\u062a\u062a\u0637\u0644\u0628 \u0623\u062d\u064a\u0627\u0646\u0627\u064b \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0644\u064a \u0645\u0646 \u0633\u064a\u0645\u0646\u0632 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0643\u0627\u0645\u0644\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0627\u0631\u0632\u0629<\/strong>: \u062a\u0634\u0648\u0643\u064a\u0643\u0627\u0645\u0627\u062a\u0627 (\u0634\u064a\u0644\u064a)\u060c \u0643\u0627\u0644\u063a\u0648\u0631\u0644\u064a (\u0623\u0633\u062a\u0631\u0627\u0644\u064a\u0627)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-xbrele-china\">4. XBRELE (\u0627\u0644\u0635\u064a\u0646)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 KYN28\/XGN15 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628 VCB<\/li>\n\n\n\n<li>\u0642\u0648\u0627\u0637\u0639 \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0644\u0644\u062a\u0639\u062f\u064a\u0646 (IP65\u060c \u0645\u0642\u0648\u0627\u0629)<\/li>\n\n\n\n<li>\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0645\u062e\u0635\u0635\u0629 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0641\u0639\u0627\u0644\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u062a\u0643\u0644\u0641\u0629<\/strong>: 40-60% \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629 \u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0645\u0643\u0627\u0641\u0626\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u062e\u0635\u064a\u0635 \u0627\u0644\u0633\u0631\u064a\u0639<\/strong>: \u0647\u0646\u062f\u0633\u0629 \u0645\u0631\u0646\u0629 \u0644\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 (\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a \u0648\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629)<\/li>\n\n\n\n<li><strong>\u062a\u0635\u0645\u064a\u0645\u0627\u062a \u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>: \u0645\u0648\u0627\u0646\u0639 \u062a\u0633\u0631\u0628 \u0627\u0644\u063a\u0628\u0627\u0631\u060c \u0648\u0645\u062e\u0645\u062f\u0627\u062a \u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u060c \u0648\u0627\u0644\u062a\u0634\u0637\u064a\u0628\u0627\u062a \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062a\u0622\u0643\u0644 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0641\u064a \u0645\u062a\u063a\u064a\u0631\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/li>\n\n\n\n<li><strong>\u0645\u0647\u0644 \u0632\u0645\u0646\u064a\u0629 \u0623\u0642\u0635\u0631<\/strong>:: 6-10 \u0623\u0633\u0627\u0628\u064a\u0639 \u0645\u0642\u0627\u0628\u0644 12-20 \u0623\u0633\u0628\u0648\u0639\u0627\u064b \u0644\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u064a\u0646<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0630\u0627\u062a \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629\u060c \u0648\u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644\/\u0627\u0644\u062a\u062c\u062f\u064a\u062f\u060c \u0648\u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u0646\u0627\u0634\u0626\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0627\u0644\u062a\u0639\u0631\u0641 \u0639\u0644\u0649 \u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0623\u0633\u0645\u0627\u0621 \u0627\u0644\u0645\u0639\u0631\u0648\u0641\u0629\u060c \u0648\u0634\u0628\u0643\u0629 \u0627\u0644\u062e\u062f\u0645\u0627\u062a \u062a\u0646\u0645\u0648 (\u0642\u0648\u064a\u0629 \u0641\u064a \u0622\u0633\u064a\u0627\/\u0623\u0641\u0631\u064a\u0642\u064a\u0627\/\u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0644\u0627\u062a\u064a\u0646\u064a\u0629)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0627\u0631\u0632\u0629<\/strong>: \u0639\u0645\u0644\u064a\u0627\u062a \u0645\u062a\u0639\u062f\u062f\u0629 \u0644\u062e\u0627\u0645 \u0627\u0644\u062d\u062f\u064a\u062f (\u0627\u0644\u0635\u064a\u0646\u060c \u0623\u0641\u0631\u064a\u0642\u064a\u0627)\u060c \u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u0641\u062d\u0645 (\u0625\u0646\u062f\u0648\u0646\u064a\u0633\u064a\u0627\u060c \u0627\u0644\u0647\u0646\u062f)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a<\/strong>:&nbsp;<a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker-manufacturer\/\">xbrele.com\/mining-switchgear.com<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-eaton-irelandusa\">5. \u0625\u064a\u062a\u0648\u0646 (\u0623\u064a\u0631\u0644\u0646\u062f\u0627\/\u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0641\u0627\u062a\u064a\u062d \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0643\u0633\u0648\u0629 \u0628\u0627\u0644\u0645\u0639\u062f\u0646 \u0645\u0646 \u0637\u0631\u0627\u0632 VacClad-W<\/li>\n\n\n\n<li>\u0642\u0648\u0627\u0637\u0639 \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0639\u0644\u0628\u0629 \u0645\u0635\u0628\u0648\u0628\u0629\/\u0639\u0644\u0628\u0629 \u0645\u0639\u0632\u0648\u0644\u0629 \u0644\u0644\u062f\u0641\u0627\u0639 \u0639\u0646 \u0627\u0644\u0637\u0627\u0642\u0629<\/li>\n\n\n\n<li>\u0645\u0631\u062d\u0644\u0627\u062a IQ200 \u0627\u0644\u0631\u0642\u0645\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0634\u0647\u0627\u062f\u0629 \u0645\u0632\u062f\u0648\u062c\u0629<\/strong>: \u062a\u0639\u0645\u0644 \u062a\u0635\u0646\u064a\u0641\u0627\u062a IEC + UL\/ANSI \u0639\u0644\u0649 \u062a\u0628\u0633\u064a\u0637 \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0645\u062a\u0639\u062f\u062f\u0629 \u0627\u0644\u062c\u0646\u0633\u064a\u0627\u062a<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629<\/strong>: \u0642\u0648\u064a\u0629 \u0641\u064a \u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0643\u0646\u062f\u064a\u0629 \u0648\u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629 \u0648\u0627\u0644\u0645\u0643\u0633\u064a\u0643\u064a\u0629 \u0648\u0627\u0644\u062a\u0634\u064a\u0644\u064a\u0629<\/li>\n\n\n\n<li><strong>\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0648\u0627\u062c\u0628 \u0627\u0644\u0642\u0627\u0633\u064a<\/strong>: \u0639\u0631\u0648\u0636 IP66\u060c \u0627\u0644\u0639\u0628\u0648\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 12\/4X\u060c \u0627\u0644\u0646\u0648\u0639 12\/4X<\/li>\n\n\n\n<li><strong>\u062e\u0628\u0631\u0629 \u0641\u064a \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a<\/strong>: \u062d\u0644\u0648\u0644 \u0645\u062a\u062e\u0635\u0635\u0629 \u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0637\u0627\u062d\u0646 \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0648\u0627\u0644\u0646\u0627\u0642\u0644\u0627\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0639\u0645\u0644\u064a\u0627\u062a \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629\/\u062c\u0646\u0648\u0628 \u0623\u0645\u0631\u064a\u0643\u0627\u060c \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u0625\u062f\u0631\u0627\u062c\u0647\u0627 \u0641\u064a \u0642\u0627\u0626\u0645\u0629 UL<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0646\u0637\u0627\u0642 \u0627\u0644\u0645\u0646\u062a\u062c \u0623\u0636\u064a\u0642 \u0645\u0646 ABB\/Schneider \u0639\u0646\u062f \u0623\u0639\u0644\u0649 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 (\u0645\u062d\u062f\u0648\u062f \u0641\u0648\u0642 15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0641\u064a \u0628\u0639\u0636 \u0627\u0644\u062e\u0637\u0648\u0637)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6.-ge-grid-solutions--ge-vernova-usaglobal\">6. GE Grid Solutions \/ GE Vernova (\u0627\u0644\u0648\u0644\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u062f\u0629 \u0627\u0644\u0623\u0645\u0631\u064a\u0643\u064a\u0629\/\u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0642\u0648\u0627\u0637\u0639 \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621 VB1<\/li>\n\n\n\n<li>\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643 EntelliGuard G5<\/li>\n\n\n\n<li>\u0623\u0646\u0638\u0645\u0629 \u062a\u0642\u0644\u064a\u0644 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0642\u064a\u0627\u062f\u0629 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>: \u0631\u064a\u0627\u062f\u0629 \u0645\u0641\u0647\u0648\u0645 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0635\u064a\u0627\u0646\u0629 (\u0648\u0636\u0639 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u064a\u0642\u0644\u0644 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0645\u0646 \u0645\u062e\u0627\u0637\u0631 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a)<\/li>\n\n\n\n<li><strong>\u062a\u0631\u0627\u062b \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629<\/strong>: \u0642\u0648\u0627\u0637\u0639 \u062c\u0646\u0631\u0627\u0644 \u0625\u0644\u0643\u062a\u0631\u064a\u0643 \u0627\u0644\u062a\u064a \u0623\u062b\u0628\u062a\u062a \u0643\u0641\u0627\u0621\u062a\u0647\u0627 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 \u0639\u0642\u0648\u062f \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0635\u0639\u0628\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0643\u0627\u0645\u0644 \u0627\u0644\u0631\u0642\u0645\u064a<\/strong>: \u0627\u0644\u062a\u062d\u0644\u064a\u0644\u0627\u062a \u0627\u0644\u062a\u0646\u0628\u0624\u064a\u0629 \u0648\u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0631\u0643\u0632 \u0639\u0644\u0649 \u0627\u0644\u0633\u0644\u0627\u0645\u0629\u060c \u0645\u0646\u0627\u062c\u0645 \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629\u060c \u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0646\u062d\u0627\u0633\/\u0627\u0644\u0630\u0647\u0628<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0625\u0639\u0627\u062f\u0629 \u0647\u064a\u0643\u0644\u0629 \u062c\u0646\u0631\u0627\u0644 \u0625\u0644\u0643\u062a\u0631\u064a\u0643 \u062e\u0644\u0642\u062a \u062d\u0627\u0644\u0629 \u0645\u0646 \u0639\u062f\u0645 \u0627\u0644\u064a\u0642\u064a\u0646 \u062d\u0648\u0644 \u0627\u0644\u062f\u0639\u0645 \u0637\u0648\u064a\u0644 \u0627\u0644\u0623\u062c\u0644 \u0648\u0639\u0644\u0627\u0648\u0629 \u0627\u0644\u062a\u0633\u0639\u064a\u0631<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"7.-weg-brazil\">7. \u0648\u064a\u063a (\u0627\u0644\u0628\u0631\u0627\u0632\u064a\u0644)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0643\u0633\u0648\u0629 \u0628\u0627\u0644\u0645\u0639\u062f\u0646 MVW01<\/li>\n\n\n\n<li>\u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 + \u062d\u0632\u0645 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062f\u0645\u062c\u0629 \u0630\u0627\u062a \u0627\u0644\u062a\u0631\u062f\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u063a\u064a\u0631\u0629 \u0627\u0644\u0645\u062a\u063a\u064a\u0631\u0629 \u0627\u0644\u0645\u062a\u063a\u064a\u0631\u0629<\/li>\n\n\n\n<li>\u0627\u0644\u0639\u0628\u0648\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629\/\u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0641\u064a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u062e\u0628\u0631\u0629 \u0627\u0644\u0628\u0631\u0627\u0632\u064a\u0644\u064a\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>: \u062a\u0634\u0645\u0644 \u0627\u0644\u0633\u0648\u0642 \u0627\u0644\u0645\u062d\u0644\u064a\u0629 \u0634\u0631\u0643\u0629 Vale\u060c \u0623\u0643\u0628\u0631 \u0645\u0646\u062a\u062c \u0644\u062e\u0627\u0645 \u0627\u0644\u062d\u062f\u064a\u062f \u0641\u064a \u0627\u0644\u0639\u0627\u0644\u0645<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062d\u0644\u0648\u0644 \u0627\u0644\u0645\u062a\u0643\u0627\u0645\u0644\u0629<\/strong>: \u062d\u0632\u0645 \u0627\u0644\u0645\u062d\u0631\u0643 + VFD + \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u062a\u0642\u0644\u0644 \u0645\u0646 \u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0648\u0635\u0644\u0629 \u0627\u0644\u0628\u064a\u0646\u064a\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629<\/strong>: \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0645\u062b\u0628\u062a\u0629 \u0641\u064a \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0628\u0631\u0627\u0632\u064a\u0644\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629<\/li>\n\n\n\n<li><strong>\u0623\u0633\u0639\u0627\u0631 \u062a\u0646\u0627\u0641\u0633\u064a\u0629<\/strong>: 30-40% \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0645\u0627\u0631\u0643\u0627\u062a \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0645\u0634\u0627\u0631\u064a\u0639 \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0644\u0627\u062a\u064a\u0646\u064a\u0629\u060c \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u062e\u0627\u0645 \u0627\u0644\u062d\u062f\u064a\u062f\u060c \u0648\u0627\u0644\u0645\u0646\u0627\u062e\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u0648\u0627\u0626\u064a\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0634\u0628\u0643\u0629 \u062e\u062f\u0645\u0627\u062a \u0639\u0627\u0644\u0645\u064a\u0629 \u0623\u0642\u0644 \u0627\u062a\u0633\u0627\u0639\u064b\u0627 \u0645\u0646 ABB\/Schneider<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0628\u0627\u0631\u0632\u0629<\/strong>: \u0639\u0645\u0644\u064a\u0627\u062a \u0634\u0631\u0643\u0629 Vale (\u0627\u0644\u0628\u0631\u0627\u0632\u064a\u0644)\u060c \u0645\u0646\u0627\u062c\u0645 \u0646\u062d\u0627\u0633\/\u0630\u0647\u0628 \u0645\u062e\u062a\u0644\u0641\u0629 \u0641\u064a \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0644\u0627\u062a\u064a\u0646\u064a\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"8.-hyundai-heavy-industries--hd-hyundai-electric-south-korea\">8. \u0647\u064a\u0648\u0646\u062f\u0627\u064a \u0644\u0644\u0635\u0646\u0627\u0639\u0627\u062a \u0627\u0644\u062b\u0642\u064a\u0644\u0629\/\u0647\u064a\u0648\u0646\u062f\u0627\u064a \u0647\u064a\u0648\u0646\u062f\u0627\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0643\u0648\u0631\u064a\u0627 \u0627\u0644\u062c\u0646\u0648\u0628\u064a\u0629)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 HYUNDAI 12-38 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/li>\n\n\n\n<li>\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u060c \u062d\u0632\u0645 VFD<\/li>\n\n\n\n<li>\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u062b\u0628\u062a\u0629 \u0639\u0644\u0649 \u0632\u0644\u0627\u062c\u0627\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0648\u062d\u062f\u0627\u062a \u0645\u0639\u064a\u0627\u0631\u064a\u0629\/\u062d\u0627\u0648\u064a\u0629<\/strong>: \u064a\u062a\u0645 \u0634\u062d\u0646 \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u0645\u062c\u0645\u0639\u0629 \u0641\u064a \u0627\u0644\u0645\u0635\u0646\u0639 \u0643\u0627\u0645\u0644\u0629\u060c \u0645\u0645\u0627 \u064a\u0642\u0644\u0644 \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0641\u064a \u0627\u0644\u0645\u0648\u0642\u0639<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0645\u0642\u062a\u0631\u062d\u0629<\/strong>: 35-45% \u0623\u0642\u0644 \u0645\u0646 \u0627\u0644\u0633\u0639\u0631 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a<\/li>\n\n\n\n<li><strong>\u062d\u0636\u0648\u0631 \u0645\u062a\u0632\u0627\u064a\u062f \u0641\u064a \u0627\u0644\u0633\u0648\u0642<\/strong>: \u0642\u0648\u064a \u0641\u064a \u0642\u0637\u0627\u0639\u064a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0641\u064a \u0622\u0633\u064a\u0627 \u0648\u0627\u0644\u0645\u062d\u064a\u0637 \u0627\u0644\u0647\u0627\u062f\u0626 \u0648\u0627\u0644\u0634\u0631\u0642 \u0627\u0644\u0623\u0648\u0633\u0637<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0645\u0633\u0627\u0631 \u0627\u0644\u0633\u0631\u064a\u0639\u060c \u0648\u0627\u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0646\u0627\u0626\u064a\u0629 (\u0627\u0644\u062d\u0644\u0648\u0644 \u0628\u0627\u0644\u062d\u0627\u0648\u064a\u0627\u062a)\u060c \u0648\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0622\u0633\u064a\u0648\u064a\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0648\u062c\u0648\u062f \u0645\u062d\u062f\u0648\u062f \u0641\u064a \u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0634\u0645\u0627\u0644\u064a\u0629\u060c \u0648\u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0645\u062a\u0623\u062e\u0631\u0629 \u0623\u062d\u064a\u0627\u0646\u064b\u0627 (\u0627\u0644\u062a\u0631\u062c\u0645\u0629 \u0645\u0646 \u0627\u0644\u0643\u0648\u0631\u064a\u0629 \u0625\u0644\u0649 \u0627\u0644\u0625\u0646\u062c\u0644\u064a\u0632\u064a\u0629)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"9.-kon\u010dar-croatia\">9. \u0643\u0648\u0646\u062a\u0634\u0627\u0631 (\u0643\u0631\u0648\u0627\u062a\u064a\u0627)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0645\u063a\u0644\u0642 \u0628\u0627\u0644\u0645\u0639\u062f\u0646<\/li>\n\n\n\n<li>\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0645\u062e\u0635\u0635\u0629<\/li>\n\n\n\n<li>\u0645\u062a\u063a\u064a\u0631\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u0629 \u0627\u0644\u0642\u0627\u0633\u064a\u0629<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062c\u0648\u062f\u0629 \u0623\u0648\u0631\u0648\u0628\u064a\u0629 + \u0623\u0633\u0639\u0627\u0631 \u0645\u0639\u062a\u062f\u0644\u0629<\/strong>: 15-25% \u0623\u062f\u0646\u0627\u0647 ABB\/Siemens<\/li>\n\n\n\n<li><strong>\u0647\u0646\u062f\u0633\u0629 \u0645\u0631\u0646\u0629<\/strong>: \u0639\u0644\u0649 \u0627\u0633\u062a\u0639\u062f\u0627\u062f \u0644\u0644\u062a\u062e\u0635\u064a\u0635 \u0644\u062a\u0644\u0628\u064a\u0629 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0641\u0631\u064a\u062f\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0631\u0643\u064a\u0632 \u0639\u0644\u0649 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0641\u064a \u0627\u0644\u0628\u0644\u0642\u0627\u0646\/\u0623\u0648\u0631\u0648\u0628\u0627 \u0627\u0644\u0634\u0631\u0642\u064a\u0629<\/strong>: \u062d\u0636\u0648\u0631 \u0625\u0642\u0644\u064a\u0645\u064a \u0642\u0648\u064a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629\u060c \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0641\u064a \u0627\u0644\u0628\u0644\u0642\u0627\u0646\/\u0627\u0644\u062a\u0631\u0643\u064a\u0629\/\u0627\u0644\u0631\u0648\u0633\u064a\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0631\u0624\u064a\u0629 \u0639\u0627\u0644\u0645\u064a\u0629 \u0645\u062d\u062f\u0648\u062f\u0629\u060c \u0645\u0646\u0638\u0645\u0629 \u062e\u062f\u0645\u0627\u062a \u0623\u0635\u063a\u0631 \u062d\u062c\u0645\u0627\u064b \u0645\u0646 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0643\u0628\u0631\u0649<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"10.-lucy-electric-ukfrance\">10. \u0644\u0648\u0633\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0627\u0644\u0645\u0645\u0644\u0643\u0629 \u0627\u0644\u0645\u062a\u062d\u062f\u0629\/\u0641\u0631\u0646\u0633\u0627)<\/h3>\n\n\n\n<p><strong>\u0645\u062d\u0641\u0638\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0648\u062d\u062f\u0627\u062a \u0631\u0626\u064a\u0633\u064a\u0629 \u062d\u0644\u0642\u064a\u0629 (RMUs) \u0644\u0644\u062a\u0648\u0632\u064a\u0639 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/li>\n\n\n\n<li>\u0645\u062d\u0637\u0627\u062a \u0641\u0631\u0639\u064a\u0629 \u062b\u0627\u0646\u0648\u064a\u0629 \u0645\u062f\u0645\u062c\u0629<\/li>\n\n\n\n<li>\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a ePACS<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0644\u0645\u0627\u0630\u0627 \u0644\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u062a\u062e\u0635\u0635 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/strong>: \u0648\u062d\u062f\u0627\u062a \u062a\u062d\u0643\u0645 \u0639\u0646 \u0628\u064f\u0639\u062f \u0645\u062f\u0645\u062c\u0629 \u0645\u062b\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0633\u0627\u062d\u0627\u062a \u0627\u0644\u0636\u064a\u0642\u0629 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u062e\u0641\u064a\u0641 \u0645\u0646 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>:: \u0623\u0646\u0638\u0645\u0629 ePACS \u0627\u0644\u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u0627 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0623\u0641\u0631\u0627\u062f<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a<\/strong>: \u064a\u062a\u064a\u062d \u0627\u0644\u062a\u0648\u0633\u0639 \u0627\u0644\u062a\u062f\u0631\u064a\u062c\u064a \u0645\u0639 \u062a\u0637\u0648\u0631 \u0627\u0644\u0645\u0646\u062c\u0645<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/strong>: \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636\u060c \u0648\u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u0628\u0639\u064a\u062f\u0629\/\u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0646\u0645\u0637\u064a\u0629\u060c \u0648\u0627\u0644\u062a\u0648\u0633\u0639\u0627\u062a \u0641\u064a \u0627\u0644\u062d\u0642\u0648\u0644 \u0627\u0644\u0628\u0646\u064a\u0629<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a<\/strong>: \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0646\u062a\u062c\u0627\u062a \u0623\u0636\u064a\u0642 (\u062a\u0631\u0643\u0632 \u0639\u0644\u0649 \u0627\u0644\u062d\u0644\u0648\u0644 \u0627\u0644\u0645\u062f\u0645\u062c\u0629\/\u0648\u062d\u062f\u0629 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0631\u0635\u062f\u060c \u0648\u0644\u064a\u0633 \u0639\u0644\u0649 \u0627\u0644\u062a\u0634\u0643\u064a\u0644\u0627\u062a \u0627\u0644\u0645\u0643\u0633\u0648\u0629 \u0628\u0627\u0644\u0645\u0639\u062f\u0646 \u0628\u0627\u0644\u0643\u0627\u0645\u0644)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-criteria-for-mining-switchgear\">\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u062e\u062a\u064a\u0627\u0631 \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-selection-criteria-scorecard.webp\" alt=\"\u0628\u0637\u0627\u0642\u0629 \u0623\u062f\u0627\u0621 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u062e\u062a\u064a\u0627\u0631 \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637\u060c \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0627\u0644\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0628\u064a\u0626\u064a\u060c \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629\u060c \u0648\u0627\u0644\u062d\u0645\u0627\u064a\u0629\u060c \u0648\u0627\u0644\u0645\u0644\u0643\u064a\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0639\u062f\u0627\u062a\" class=\"wp-image-2586\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-selection-criteria-scorecard.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-selection-criteria-scorecard-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-selection-criteria-scorecard-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-selection-criteria-scorecard-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u062a\u0633\u0627\u0639\u062f \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0645\u0647\u064a\u0643\u0644\u0629 \u0641\u0631\u0642 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u064a\u0646 \u0645\u062c\u0645\u0648\u0639\u0627\u062a \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0628\u0645\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c \u0648\u0623\u0642\u0644 \u0627\u0644\u0639\u0637\u0627\u0621\u0627\u062a.\r<br><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-environmental-ratings-critical\">1. \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u064a\u0629 (\u062d\u0631\u062c\u0629)<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u0636\u0645\u064a\u0645\u0629<\/strong>: IP65 (\u0639\u0644\u0649 \u0627\u0644\u0633\u0637\u062d)\u060c IP66 (\u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636\/\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u063a\u0633\u064a\u0644)<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639<\/strong>: \u0627\u0644\u062a\u062e\u0641\u064a\u0641 \u0623\u0648 \u0627\u0644\u0632\u064a\u0627\u062f\u0629 \u062d\u0633\u0628 IEC 62271-1 \u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0645\u0648\u0642\u0639<\/li>\n\n\n\n<li><strong>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629<\/strong>:: \u0646\u0637\u0627\u0642 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0645\u0646 -40 \u0625\u0644\u0649 +55 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 (\u0639\u0644\u0649 \u0627\u0644\u0633\u0637\u062d)\u060c \u0648\u0645\u0646 +40 \u0625\u0644\u0649 +60 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 (\u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636)<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632<\/strong>: \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u062d\u0633\u0628 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 60068-2-6 \u0623\u0648 IEEE 693 \u0644\u0644\u062a\u0623\u0647\u064a\u0644 \u0627\u0644\u0632\u0644\u0632\u0627\u0644\u064a<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0622\u0643\u0644<\/strong>: NEMA 4X\/4X\/IP66 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 \u0623\u0648 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0637\u0644\u064a \u0628\u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a \u0644\u0644\u0623\u062c\u0648\u0627\u0621 \u0627\u0644\u0645\u0633\u0628\u0628\u0629 \u0644\u0644\u062a\u0622\u0643\u0644<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629<\/strong>: \u0637\u0644\u0628 \u0634\u0647\u0627\u062f\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631 \u062a\u064f\u0638\u0647\u0631 \u0627\u0644\u0645\u0624\u0647\u0644\u0627\u062a \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629\u060c \u0648\u0644\u064a\u0633 \u0645\u062c\u0631\u062f \u0627\u062f\u0639\u0627\u0621\u0627\u062a \u201c\u0645\u0646\u0627\u0633\u0628 \u0644\u0644\u062a\u0639\u062f\u064a\u0646\u201d.\u201d<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-maintenance-and-serviceability\">2. \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0644\u0635\u0644\u0627\u062d\u064a\u0629<\/h3>\n\n\n\n<p><strong>\u062a\u0642\u064a\u064a\u0645<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062a\u0635\u0645\u064a\u0645 \u0645\u0639\u064a\u0627\u0631\u064a<\/strong>: \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062b\u0627\u0628\u062a\u0629 (\u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628 \u062a\u062a\u064a\u062d \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u062f\u0648\u0646 \u062a\u0641\u0643\u064a\u0643 \u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644)<\/li>\n\n\n\n<li><strong>\u062a\u0648\u0627\u0641\u0631 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u0645\u062d\u0644\u064a\u0629<\/strong>: \u062a\u062d\u062a\u0641\u0638 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0628\u0627\u0644\u0645\u062e\u0632\u0648\u0646 \u0641\u064a \u063a\u0636\u0648\u0646 24 \u0633\u0627\u0639\u0629 \u062a\u0633\u0644\u064a\u0645\u061f<\/li>\n\n\n\n<li><strong>MTTR (\u0645\u062a\u0648\u0633\u0637 \u0648\u0642\u062a \u0627\u0644\u0625\u0635\u0644\u0627\u062d)<\/strong>: &lt;\u0623\u0642\u0644 \u0645\u0646 4 \u0633\u0627\u0639\u0627\u062a \u0644\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0634\u0627\u0626\u0639\u0629\u061f<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u062f\u0631\u064a\u0628<\/strong>: \u062a\u0648\u0641\u0631 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u0628 \u0641\u064a \u0627\u0644\u0645\u0648\u0642\u0639 \u0644\u0637\u0627\u0642\u0645 \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u061f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0639\u0644\u0645 \u0627\u0644\u0623\u062d\u0645\u0631<\/strong>: \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0628\u062f\u0648\u0646 \u0648\u062c\u0648\u062f \u062e\u062f\u0645\u0629 \u0645\u062d\u0644\u064a\u0629\u060c \u0645\u0645\u0627 \u064a\u062a\u0637\u0644\u0628 \u0625\u0631\u0633\u0627\u0644\u0647\u0627 \u062f\u0648\u0644\u064a\u064b\u0627 \u0644\u0644\u0625\u0635\u0644\u0627\u062d\u0627\u062a<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-fault-protection-speed-and-coordination\">3. \u0633\u0631\u0639\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u0627\u0644\u062a\u0646\u0633\u064a\u0642<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0623\u0631\u0636\u064a<\/strong>: \u062d\u0633\u0627\u0633\u0629 (\u0627\u0644\u062a\u0642\u0627\u0637 5-10 \u0623\u0645\u0628\u064a\u0631) \u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0623\u0641\u0631\u0627\u062f\u060c \u0648\u0644\u0643\u0646 \u0627\u0646\u062a\u0642\u0627\u0626\u064a\u0629 (\u062a\u062c\u0646\u0628 \u0627\u0644\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0645\u0632\u0639\u062c\u0629 \u0645\u0646 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0633\u0631\u0628 \u0641\u064a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0632\u0627\u0626\u062f\u0629)<\/li>\n\n\n\n<li><strong>\u062a\u0642\u0644\u064a\u0644 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>: \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u060c \u0623\u0648 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0628\u062f\u064a\u0644\u060c \u0623\u0648 \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0627\u0646\u062a\u0642\u0627\u0626\u064a \u0644\u0644\u0645\u0646\u0637\u0642\u0629\u060c \u0623\u0648 \u0623\u0646\u0638\u0645\u0629 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0636\u0648\u0626\u064a<\/li>\n\n\n\n<li><strong>\u0627\u0644\u062a\u0646\u0633\u064a\u0642<\/strong>: \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0639 \u0645\u0631\u0641\u0642 \u0627\u0644\u0645\u0646\u062c\u0645 \u0641\u064a \u0627\u0644\u0645\u0646\u0628\u0639 \u0648\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0641\u064a \u0627\u0644\u0645\u0635\u0628<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0623\u062f\u0627\u0629<\/strong>: \u0627\u0637\u0644\u0628 \u0645\u0646 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0625\u062c\u0631\u0627\u0621 \u062f\u0631\u0627\u0633\u0629 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u062a\u0646\u0633\u064a\u0642 \u0644\u062a\u0631\u0643\u064a\u0628\u0643 \u0627\u0644\u0645\u062d\u062f\u062f<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-total-cost-of-ownership-20-year-horizon\">4. \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629 (\u0623\u0641\u0642 20 \u0633\u0646\u0629)<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0638\u0631 \u0641\u064a \u0645\u0627 \u0628\u0639\u062f \u0633\u0639\u0631 \u0627\u0644\u0634\u0631\u0627\u0621<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0645\u0643\u0648\u0646 \u0627\u0644\u062a\u0643\u0644\u0641\u0629<\/th><th>% \u0646\u0645\u0648\u0630\u062c\u064a % \u0645\u0646 TCO<\/th><\/tr><\/thead><tbody><tr><td>\u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0631\u0623\u0633\u0645\u0627\u0644\u064a\u0629 \u0627\u0644\u0623\u0648\u0644\u064a\u0629<\/td><td>40-50% 40-50%<\/td><\/tr><tr><td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628\/\u0627\u0644\u062a\u0643\u0644\u064a\u0641<\/td><td>10-15%<\/td><\/tr><tr><td>\u0627\u0644\u0635\u064a\u0627\u0646\u0629 (\u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 + \u0627\u0644\u0639\u0645\u0627\u0644\u0629)<\/td><td>15-25%<\/td><\/tr><tr><td>\u062a\u0643\u0644\u0641\u0629 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 (\u062e\u0633\u0627\u0631\u0629 \u0627\u0644\u0625\u0646\u062a\u0627\u062c)<\/td><td>15-30%<\/td><\/tr><tr><td>\u0641\u0627\u0642\u062f \u0627\u0644\u0637\u0627\u0642\u0629<\/td><td>5-10%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>\u0633\u064a\u0627\u0642 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/strong>: \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0647\u064a\u0645\u0646 \u062a\u0643\u0644\u0641\u0629 \u0648\u0642\u062a \u0627\u0644\u062a\u0648\u0642\u0641 \u0639\u0646 \u0627\u0644\u0639\u0645\u0644 - \u0642\u062f \u062a\u0643\u0648\u0646 \u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629 \u0623\u0642\u0644 \u0639\u0644\u0649 \u0627\u0644\u0631\u063a\u0645 \u0645\u0646 \u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0631\u0623\u0633\u0645\u0627\u0644\u064a\u0629<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-manufacturer-track-record-in-mining\">5. \u0633\u062c\u0644 \u0627\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0637\u0631\u062d\u0647\u0627<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u062a\u0648\u0641\u064a\u0631 3 \u0645\u0648\u0627\u0642\u0639 \u0645\u0631\u062c\u0639\u064a\u0629 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u062a\u0639\u062f\u064a\u0646 \u0645\u0645\u0627\u062b\u0644\u0629 (\u0646\u0648\u0639 \u0627\u0644\u062e\u0627\u0645\u060c \u0627\u0644\u0645\u0648\u0642\u0639\u060c \u0627\u0644\u0628\u064a\u0626\u0629)\u201d<\/li>\n\n\n\n<li>\u201c\u0645\u0627 \u0647\u064a \u0623\u0643\u0628\u0631 \u0645\u0646\u0634\u0623\u0629 \u062a\u0639\u062f\u064a\u0646 \u0644\u062f\u064a\u0643\u0645 \u0645\u0646 \u062d\u064a\u062b \u0633\u0639\u0629 \u0627\u0644\u0637\u0627\u0642\u0629\u061f\u201d<\/li>\n\n\n\n<li>\u201c\u0643\u0645 \u0639\u062f\u062f \u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0639\u0645\u0644 \u0641\u0648\u0642 \u0627\u0631\u062a\u0641\u0627\u0639 3,000 \u0645\u062a\u0631\u061f\u201d<\/li>\n\n\n\n<li>\u201c\u0645\u0627 \u0647\u064a \u0627\u0644\u0645\u0647\u0644\u0629 \u0627\u0644\u0632\u0645\u0646\u064a\u0629 \u0627\u0644\u0645\u0639\u062a\u0627\u062f\u0629 \u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0645\u0647\u0627\u0645 \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u061f\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0632\u064a\u0627\u0631\u0629 \u0627\u0644\u0645\u0648\u0642\u0639<\/strong>: \u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0643\u0628\u064a\u0631\u064b\u0627\u060c \u0642\u0645 \u0628\u0632\u064a\u0627\u0631\u0629 \u0645\u0646\u062c\u0645 \u0645\u0631\u062c\u0639\u064a \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0639\u062f\u0627\u062a \u062a\u0644\u0643 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 - \u0644\u0627\u062d\u0638 \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0628\u0639\u062f \u0633\u0646\u0648\u0627\u062a \u0645\u0646 \u0627\u0644\u062e\u062f\u0645\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mining-application-specific-considerations\">\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a \u062e\u0627\u0635\u0629 \u0628\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"surface-operations\">\u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0633\u0637\u062d\u064a\u0629<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/strong>: \u0627\u0644\u063a\u0628\u0627\u0631\u060c \u0648\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0642\u0635\u0648\u0649\u060c \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 (\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0623\u0644\u063a\u0627\u0645 \u0627\u0644\u0645\u0631\u062a\u0641\u0639\u0629)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0636\u0644\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062d\u0627\u0648\u064a\u0627\u062a \u062e\u0627\u0631\u062c\u064a\u0629 \u0645\u0643\u0633\u0648\u0629 \u0628\u0627\u0644\u0645\u0639\u062f\u0646 IP65+ IP65+<\/li>\n\n\n\n<li>\u062a\u0647\u0648\u064a\u0629 \u0628\u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0645\u0648\u062c\u0628 \u0645\u0639 \u0645\u062f\u062e\u0644 \u0647\u0648\u0627\u0621 \u0645\u0641\u0644\u062a\u0631<\/li>\n\n\n\n<li>\u0633\u062e\u0627\u0646\u0627\u062a\/\u0645\u0646\u0638\u0645\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0644\u0644\u0645\u0646\u0627\u062e\u0627\u062a \u0627\u0644\u0628\u0627\u0631\u062f\u0629<\/li>\n\n\n\n<li>\u062a\u0635\u062d\u064a\u062d \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 (\u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0623\u0643\u062b\u0631 \u0645\u0646 1,000 \u0645\u062a\u0631)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0627\u062a<\/strong>: ABB\u060c \u0634\u0646\u0627\u064a\u062f\u0631 (\u062e\u0628\u0631\u0629 \u0645\u062b\u0628\u062a\u0629 \u0641\u064a \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0637\u0644\u0642\/\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a)\u060c XBRELE (\u062e\u064a\u0627\u0631\u0627\u062a \u0641\u0639\u0627\u0644\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u062a\u0643\u0644\u0641\u0629)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"underground-mines\">\u0627\u0644\u0645\u0646\u0627\u062c\u0645 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/strong>: \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629\u060c \u0648\u0636\u064a\u0642 \u0627\u0644\u0645\u0633\u0627\u062d\u0629\u060c \u0648\u0627\u0644\u0633\u0644\u0627\u0645\u0629 (\u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0627\u0644\u062e\u0637\u0623 \u0627\u0644\u0623\u0631\u0636\u064a)<\/p>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0636\u0644\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0645\u062f\u0645\u062c\u0629\/\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u063a\u0627\u0632 (\u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u0645\u0633\u0627\u062d\u0629)<\/li>\n\n\n\n<li>\u0645\u0639\u064a\u0627\u0631 IP66 \u0644\u0645\u0646\u0627\u0637\u0642 \u0627\u0644\u063a\u0633\u064a\u0644<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062d\u0633\u0651\u0646 (\u062a\u0647\u0648\u064a\u0629 \u0642\u0633\u0631\u064a\u0629\u060c \u0645\u0628\u0627\u062f\u0644\u0627\u062a \u062d\u0631\u0627\u0631\u064a\u0629 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u0623\u0643\u062b\u0631 \u0645\u0646 40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629)<\/li>\n\n\n\n<li>\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0623\u0631\u0636\u064a &lt;10 \u0623\u0645\u0628\u064a\u0631\u060c \u0627\u062a\u062c\u0627\u0647\u064a \u0641\u064a \u062d\u0627\u0644\u0629 \u062a\u0639\u062f\u062f \u0627\u0644\u0645\u063a\u0630\u064a\u0627\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0627\u062a<\/strong>: \u0634\u0646\u0627\u064a\u062f\u0631 (RM6 \u0627\u0644\u0645\u062f\u0645\u062c\u0629)\u060c \u0644\u0648\u0633\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643 (\u0645\u062a\u062e\u0635\u0635\u0648\u0646 \u0641\u064a \u0648\u062d\u062f\u0629 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0645\u062e\u0627\u0637\u0631)\u060c \u0633\u064a\u0645\u0646\u0632 (\u0647\u0648\u0627\u0621 \u0646\u0638\u064a\u0641 \u062e\u0627\u0644\u064d \u0645\u0646 SF6)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mobile-equipment-draglines-shovels-continuous-miners\">\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629 (\u0627\u0644\u062c\u0631\u0627\u0641\u0627\u062a \u0648\u0627\u0644\u0645\u062c\u0627\u0631\u0641 \u0648\u0622\u0644\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0645\u0633\u062a\u0645\u0631)<\/h3>\n\n\n\n<p><strong>\u0627\u0644\u062a\u062d\u062f\u064a\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/strong>: \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u060c \u0648\u062a\u0648\u0635\u064a\u0644\/\u0641\u0635\u0644 \u0627\u0644\u0643\u0627\u0628\u0644 \u0627\u0644\u0632\u0627\u0626\u062f\u060c \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632<\/p>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0636\u0644\u0629<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062d\u0645\u0644 (\u0645\u0635\u0646\u0641\u0629 \u0623\u0643\u062b\u0631 \u0645\u0646 100,000 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644)<\/li>\n\n\n\n<li>\u0646\u0647\u0627\u064a\u0627\u062a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0642\u0648\u064a\u0629 (\u0644\u064a\u0633\u062a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0645\u062b\u0628\u062a \u0628\u0639\u0631\u0648\u0627\u062a \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u062a\u064a \u062a\u062a\u062d\u0645\u0644 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631)<\/li>\n\n\n\n<li>\u062a\u0635\u0627\u0645\u064a\u0645 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0648\u0635\u064a\u0644\/\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628 \u0644\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0633\u0631\u064a\u0639<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0627\u062a<\/strong>: ABB (\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a)\u060c XBRELE (\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646)\u060c \u0625\u064a\u062a\u0648\u0646 (\u062e\u0628\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"procurement-strategy\">\u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a\u0629 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"competitive-bid-structure\">\u0647\u064a\u0643\u0644 \u0627\u0644\u0639\u0637\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u0646\u0627\u0641\u0633\u064a\u0629<\/h3>\n\n\n\n<p><strong>\u062f\u0639\u0648\u0629 3-4 \u0634\u0631\u0643\u0627\u062a \u0645\u0635\u0646\u0639\u0629<\/strong>&nbsp;\u062a\u063a\u0637\u064a \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0645\u062e\u062a\u0644\u0641\u0629:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0627\u0644\u0641\u0626\u0629 \u0627\u0644\u0645\u0645\u062a\u0627\u0632\u0629<\/strong>\u00a0(ABB \u0623\u0648 \u0634\u0646\u0627\u064a\u062f\u0631): \u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633 \u0644\u0644\u0645\u0642\u0627\u0631\u0646\u0629\u060c \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0645\u0639\u0631\u0648\u0641\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0645\u062a\u0648\u0633\u0637<\/strong>\u00a0(XBRELE\u060c WEG\u060c \u0625\u064a\u062a\u0648\u0646): \u0623\u0633\u0639\u0627\u0631 \u062a\u0646\u0627\u0641\u0633\u064a\u0629 \u0648\u0623\u062f\u0627\u0621 \u0645\u0646\u0627\u0633\u0628<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0623\u062e\u0635\u0627\u0626\u064a<\/strong>\u00a0(\u0644\u0648\u0633\u064a \u0625\u0644\u0643\u062a\u0631\u064a\u0643 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636\u060c \u062c\u0646\u0631\u0627\u0644 \u0625\u0644\u0643\u062a\u0631\u064a\u0643 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062d\u0631\u062c\u064b\u0627): \u0646\u0642\u0627\u0637 \u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0645\u062d\u062f\u062f\u0629<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0645\u0635\u0641\u0648\u0641\u0629 \u0627\u0644\u062a\u0642\u064a\u064a\u0645<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0645\u0639\u064a\u0627\u0631<\/th><th>\u0627\u0644\u0648\u0632\u0646<\/th><th>\u0637\u0631\u064a\u0642\u0629 \u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u0646\u0642\u0627\u0637<\/th><\/tr><\/thead><tbody><tr><td>\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0627\u0644\u062a\u0642\u0646\u064a<\/td><td>35%<\/td><td>\u0627\u0644\u0646\u062c\u0627\u062d\/\u0627\u0644\u0631\u0633\u0648\u0628 + \u0627\u0644\u0647\u0627\u0645\u0634 \u0625\u0644\u0649 \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a<\/td><\/tr><tr><td>\u0627\u0644\u0633\u0639\u0631 (\u0631\u0623\u0633 \u0627\u0644\u0645\u0627\u0644 + \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0644\u0645\u062f\u0629 10 \u0633\u0646\u0648\u0627\u062a)<\/td><td>30%<\/td><td>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0642\u062f\u0645 \u0627\u0644\u0639\u0637\u0627\u0621 \u0627\u0644\u0623\u0642\u0644 \u0633\u0639\u0631\u064b\u0627<\/td><\/tr><tr><td>\u062c\u062f\u0648\u0644 \u0627\u0644\u062a\u0633\u0644\u064a\u0645<\/td><td>15%<\/td><td>\u0623\u062d\u0643\u0627\u0645 \u0627\u0644\u062c\u0632\u0627\u0621\u0627\u062a \u0641\u064a \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0645\u062d\u062f\u062f<\/td><\/tr><tr><td>\u0627\u0644\u062e\u0628\u0631\u0629 \u0641\u064a \u0645\u062c\u0627\u0644 \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/td><td>10%<\/td><td>\u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0627\u0644\u0645\u0631\u062c\u0639\u064a\u0629\u060c \u0633\u0646\u0648\u0627\u062a \u0641\u064a \u0627\u0644\u062a\u0639\u062f\u064a\u0646<\/td><\/tr><tr><td>\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0645\u062d\u0644\u064a<\/td><td>10%<\/td><td>\u0648\u062c\u0648\u062f \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0648\u0645\u062e\u0632\u0648\u0646 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"standardization-vs-best-of-breed\">\u0627\u0644\u062a\u0648\u062d\u064a\u062f \u0627\u0644\u0642\u064a\u0627\u0633\u064a \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0623\u0641\u0636\u0644 \u0645\u0646 \u0646\u0648\u0639\u0647\u0627<\/h3>\n\n\n\n<p><strong>\u0646\u0647\u062c \u0627\u0644\u062a\u0648\u062d\u064a\u062f \u0627\u0644\u0642\u064a\u0627\u0633\u064a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0645\u064f\u0635\u0646\u0650\u0651\u0639 \u0648\u0627\u062d\u062f \u0644\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0645\u0632\u0627\u064a\u0627<\/strong>: \u0627\u0644\u0642\u0648\u0627\u0633\u0645 \u0627\u0644\u0645\u0634\u062a\u0631\u0643\u0629 \u0644\u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631\u060c \u0648\u0628\u0631\u0646\u0627\u0645\u062c \u0627\u0644\u062a\u062f\u0631\u064a\u0628 \u0627\u0644\u0648\u0627\u062d\u062f\u060c \u0648\u0627\u0644\u0627\u0633\u062a\u0641\u0627\u062f\u0629 \u0645\u0646 \u062a\u0633\u0639\u064a\u0631 \u0627\u0644\u062d\u062c\u0645<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0639\u064a\u0648\u0628<\/strong>: \u0642\u062f \u0644\u0627 \u062a\u062d\u0635\u0644 \u0639\u0644\u0649 \u0627\u0644\u062d\u0644 \u0627\u0644\u0623\u0645\u062b\u0644 \u0644\u0643\u0644 \u062a\u0637\u0628\u064a\u0642<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u0646\u0647\u062c \u0627\u0644\u0623\u0641\u0636\u0644 \u0645\u0646 \u0646\u0648\u0639\u0647<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c \u0634\u0646\u0627\u064a\u062f\u0631 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636\u060c ABB \u0627\u0644\u0633\u0637\u062d\u064a\u0629\u060c XBRELE \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629)<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0645\u0632\u0627\u064a\u0627<\/strong>: \u0627\u0644\u0645\u0644\u0627\u0621\u0645\u0629 \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0627\u0644\u0645\u062b\u0644\u0649 \u0644\u0643\u0644 \u0628\u064a\u0626\u0629<\/li>\n\n\n\n<li><strong>\u0627\u0644\u0639\u064a\u0648\u0628<\/strong>: \u0645\u062e\u0632\u0648\u0646\u0627\u062a \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0639\u062f\u062f\u0629\u060c \u0648\u062a\u0639\u0642\u064a\u062f\u0627\u062a \u0627\u0644\u062a\u062f\u0631\u064a\u0628\u060c \u0648\u0632\u064a\u0627\u062f\u0629 \u0639\u0628\u0621 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0627\u0644\u062a\u0648\u0635\u064a\u0629<\/strong>: \u0627\u0644\u062a\u0648\u062d\u064a\u062f \u062f\u0627\u062e\u0644 \u0627\u0644\u0641\u0626\u0627\u062a (\u0639\u0644\u0649 \u0633\u0628\u064a\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u060c \u062c\u0647\u0629 \u062a\u0635\u0646\u064a\u0639 \u0648\u0627\u062d\u062f\u0629 \u0644\u062c\u0645\u064a\u0639 \u0627\u0644\u0641\u0626\u0627\u062a \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0648\u0623\u062e\u0631\u0649 \u0644\u062c\u0645\u064a\u0639 \u0627\u0644\u0641\u0626\u0627\u062a \u0627\u0644\u0633\u0637\u062d\u064a\u0629) \u0648\u0644\u0643\u0646 \u0645\u0639 \u0627\u0644\u0633\u0645\u0627\u062d \u0628\u0648\u062c\u0648\u062f \u062c\u0647\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0645\u062e\u062a\u0644\u0641\u0629 \u0644\u0643\u0644 \u0641\u0626\u0629<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u062a\u062a\u062c\u0627\u0648\u0632 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 - \u0627\u0644\u063a\u0628\u0627\u0631 (IP65+ \u0645\u0642\u0627\u0628\u0644 IP54)\u060c \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632 (\u0645\u0624\u0647\u0644 \u0644\u0644\u0632\u0644\u0627\u0632\u0644\/\u0627\u0644\u0627\u0646\u0641\u062c\u0627\u0631)\u060c \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 (\u0639\u0648\u0627\u0645\u0644 \u0627\u0644\u062a\u0635\u062d\u064a\u062d 1.10-1.25\u00d7 \u0644\u0623\u0639\u0644\u0649 \u0645\u0646 2000 \u0645\u062a\u0631)\u060c \u0648\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0642\u0635\u0648\u0649 \u062a\u062a\u0637\u0644\u0628 \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u0647\u0630\u0627 \u0627\u0644\u063a\u0631\u0636<\/li>\n\n\n\n<li>\u064a\u0628\u0631\u0631 \u0627\u0644\u0645\u0635\u0646\u0639\u0648\u0646 \u0627\u0644\u0645\u062a\u0645\u064a\u0632\u0648\u0646 (ABB\u060c \u0634\u0646\u0627\u064a\u062f\u0631\u060c \u0633\u064a\u0645\u0646\u0632) \u0639\u0644\u0627\u0648\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 20-40% \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u062d\u0627\u0641\u0638 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0645\u062b\u0628\u062a\u0629\u060c \u0648\u0634\u0628\u0643\u0627\u062a \u0627\u0644\u062e\u062f\u0645\u0629 \u0627\u0644\u0639\u0627\u0644\u0645\u064a\u0629\u060c \u0648\u0627\u0644\u062e\u0628\u0631\u0629 \u0641\u064a \u062a\u062e\u0641\u064a\u0641 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a - \u0648\u0647\u064a \u0636\u0631\u0648\u0631\u064a\u0629 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0630\u0627\u062a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629 \u0644\u0644\u0633\u0644\u0627\u0645\u0629<\/li>\n\n\n\n<li>\u062a\u0642\u062f\u0645 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0645\u062a\u0648\u0633\u0637 (XBRELE\u060c WEG\u060c \u0625\u064a\u062a\u0648\u0646) \u0648\u0641\u0648\u0631\u0627\u062a \u0641\u064a \u0627\u0644\u062a\u0643\u0644\u0641\u0629 30-50% \u0645\u0639 \u0623\u062f\u0627\u0621 \u0645\u0646\u0627\u0633\u0628 \u0644\u0644\u0645\u0634\u0627\u0631\u064a\u0639 \u0630\u0627\u062a \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629\u060c \u0623\u0648 \u0627\u0644\u0623\u0633\u0648\u0627\u0642 \u0627\u0644\u0646\u0627\u0634\u0626\u0629\u060c \u0623\u0648 \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 - \u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0645\u062d\u0644\u064a \u0642\u0628\u0644 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631<\/li>\n\n\n\n<li>\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0647\u064a\u0645\u0646 \u062a\u0643\u0644\u0641\u0629 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 (15-301 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a \u0645\u0646 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629) \u0639\u0644\u0649 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0631\u0623\u0633\u0645\u0627\u0644\u064a\u0629 - \u062a\u0648\u0641\u0631 \u0627\u0644\u062a\u0635\u0627\u0645\u064a\u0645 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629\/\u0627\u0644\u062a\u0635\u0627\u0645\u064a\u0645 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628 \u0627\u0644\u062a\u064a \u062a\u062a\u064a\u062d \u0623\u0642\u0644 \u0645\u0646 4 \u0633\u0627\u0639\u0627\u062a \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 \u0642\u064a\u0645\u0629 \u0623\u0641\u0636\u0644 \u0645\u0646 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062b\u0627\u0628\u062a\u0629 \u0627\u0644\u0623\u0642\u0644 \u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u0623\u064a\u0627\u0645\u064b\u0627 \u0644\u0644\u0625\u0635\u0644\u0627\u062d<\/li>\n\n\n\n<li>\u0648\u062a\u0639\u0637\u064a \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636 \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u0644\u0628\u0635\u0645\u0629 \u0627\u0644\u0645\u062f\u0645\u062c\u0629 (\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0639\u0632\u0644 \u0628\u0627\u0644\u063a\u0627\u0632\u060c \u0648\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0639\u0646 \u0628\u0639\u062f) \u0648\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0623\u0641\u0631\u0627\u062f (\u062e\u0637\u0623 \u0623\u0631\u0636\u064a &lt;10 \u0623\u0645\u0628\u064a\u0631\u060c \u0648\u0623\u0646\u0638\u0645\u0629 \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a)\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0631\u0643\u0632 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0633\u0637\u062d\u064a\u0629 \u0639\u0644\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0628\u064a\u0626\u0629 (IP65+\u060c \u0648\u062a\u0635\u062d\u064a\u062d \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639) \u0648\u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629 \u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062d\u0645\u0644 (\u0623\u0643\u062b\u0631 \u0645\u0646 100,000 \u0639\u0645\u0644\u064a\u0629)<\/li>\n\n\n\n<li>\u0637\u0644\u0628 \u0645\u0631\u0627\u062c\u0639 \u062a\u0639\u062f\u064a\u0646 \u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639\u0627\u062a\/\u0628\u064a\u0626\u0629 \u0645\u0645\u0627\u062b\u0644\u0629\u060c \u0648\u0625\u062c\u0631\u0627\u0621 \u0632\u064a\u0627\u0631\u0627\u062a \u0644\u0644\u0645\u0648\u0642\u0639 \u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0628\u0639\u062f \u0633\u0646\u0648\u0627\u062a \u0645\u0646 \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0648\u0637\u0644\u0628 \u062f\u0631\u0627\u0633\u0627\u062a \u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\/\u0627\u0644\u062a\u0646\u0633\u064a\u0642 \u0643\u062c\u0632\u0621 \u0645\u0646 \u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0639\u0637\u0627\u0621<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u0645\u0631\u062c\u0639 \u062e\u0627\u0631\u062c\u064a:<\/strong>&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">IEC 62271-106<\/a>&nbsp;- \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 IEC 62271-106 \u0644\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629<\/h2>\n\n\n\n<p><strong>\u0633 1: \u0647\u0644 \u064a\u0645\u0643\u0646\u0646\u064a \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0641\u0627\u062a\u064a\u062d \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0635\u0646\u0627\u0639\u064a\u0629 \u0642\u064a\u0627\u0633\u064a\u0629 \u0641\u064a \u0645\u0646\u062c\u0645 \u0628\u062a\u0635\u0646\u064a\u0641\u0627\u062a IP \u0623\u0639\u0644\u0649 \u0641\u0642\u0637\u061f<\/strong><br>\u062c: \u064a\u062a\u0637\u0644\u0628 \u0639\u062f\u0645 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u062a\u063a\u064a\u064a\u0631\u0627\u062a \u0645\u062a\u0643\u0627\u0645\u0644\u0629 \u0641\u064a \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u062a\u062a\u062c\u0627\u0648\u0632 \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0636\u0645\u064a\u0645\u0629: \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0642\u0648\u0627\u0629 \u0628\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a (\u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0645\u0642\u0648\u0627\u0629\u060c \u0648\u0627\u0644\u0645\u062b\u0628\u062a\u0627\u062a \u0627\u0644\u0633\u0644\u0643\u064a\u0629 \u0627\u0644\u0645\u0642\u0648\u0627\u0629)\u060c \u0648\u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0645\u0635\u062d\u062d \u0644\u0644\u0627\u0631\u062a\u0641\u0627\u0639 (BIL \u0623\u0639\u0644\u0649 \u0641\u064a \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639)\u060c \u0648\u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062d\u0633\u0651\u0646 (\u062a\u0628\u0631\u064a\u062f \u0643\u0628\u064a\u0631 \u0627\u0644\u062d\u062c\u0645 \u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0628\u064a\u0626\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636)\u060c \u0648\u0627\u0644\u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0644\u0644\u0625\u0635\u0644\u0627\u062d \u0627\u0644\u0633\u0631\u064a\u0639. \u062a\u0641\u0634\u0644 \u0628\u0628\u0633\u0627\u0637\u0629 \u0625\u0636\u0627\u0641\u0629 \u062d\u0627\u0648\u064a\u0629 IP66 \u0625\u0644\u0649 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0641\u064a \u0628\u064a\u0626\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646.<\/p>\n\n\n\n<p><strong>\u06332: \u0645\u0627 \u0647\u0648 \u0639\u0627\u0645\u0644 \u062a\u0635\u062d\u064a\u062d \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0630\u064a \u064a\u062c\u0628 \u0623\u0646 \u0623\u0637\u0628\u0642\u0647 \u0639\u0644\u0649 \u0644\u063a\u0645 \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 3500 \u0645\u062a\u0631\u061f<\/strong><br>\u062c: \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 62271-1\u060c \u0639\u0627\u0645\u0644 \u0627\u0644\u062a\u0635\u062d\u064a\u062d Ka = 1 + 0.012 (H - 1000) \u062d\u064a\u062b H \u0647\u0648 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0628\u0627\u0644\u0623\u0645\u062a\u0627\u0631. \u0639\u0644\u0649 \u0627\u0631\u062a\u0641\u0627\u0639 3500 \u0645\u062a\u0631: Ka = 1 + 0.012 (3500 - 1000) = 1.30. \u0627\u0636\u0631\u0628 BIL \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0641\u064a 1.30 \u0623\u0648 \u0642\u0645 \u0628\u0627\u0634\u062a\u0642\u0627\u0642 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0628\u0645\u0642\u062f\u0627\u0631 1\/1.30 \u2248 0.77 (\u0627\u0634\u062a\u0642\u0627\u0642 23%). \u062a\u062d\u0642\u0642 \u062f\u0627\u0626\u0645\u064b\u0627 \u0645\u0646 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629.<\/p>\n\n\n\n<p><strong>\u06333: \u0647\u0644 \u064a\u062c\u0628 \u062a\u062d\u062f\u064a\u062f SF6 \u0623\u0648 \u0642\u0648\u0627\u0637\u0639 \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u061f<\/strong><br>\u062c: \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 (VCBs) \u0627\u0644\u0645\u0641\u0636\u0644\u0629 \u0644\u0644\u062a\u0639\u062f\u064a\u0646: \u0644\u0627 \u062a\u0648\u062c\u062f \u0645\u0634\u0627\u0643\u0644 \u0641\u064a \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0627\u0644\u0628\u064a\u0626\u064a \u0644\u0640 SF6\u060c \u0648\u0644\u0627 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u0635\u064a\u0627\u0646\u0629 (\u0644\u0627 \u062a\u0648\u062c\u062f \u0645\u0631\u0627\u0642\u0628\u0629 \u0644\u0644\u063a\u0627\u0632)\u060c \u0648\u062a\u0639\u0645\u0644 \u0628\u0634\u0643\u0644 \u062c\u064a\u062f \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0627\u0644\u0645\u062a\u0631\u0628\u0629 (\u0642\u0627\u0637\u0639 \u0645\u062d\u0643\u0645 \u0627\u0644\u0625\u063a\u0644\u0627\u0642)\u060c \u0648\u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629. SF6 \u0645\u0642\u0628\u0648\u0644 \u0641\u064a \u0627\u0644\u062a\u0635\u0627\u0645\u064a\u0645 \u0627\u0644\u0645\u062f\u0645\u062c\u0629 \u0627\u0644\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u063a\u0627\u0632 (\u0642\u064a\u0648\u062f \u0627\u0644\u0645\u0633\u0627\u062d\u0629 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636) \u0648\u0644\u0643\u0646\u0647 \u064a\u0636\u064a\u0641 \u0639\u0628\u0621 \u0627\u0644\u0625\u0628\u0644\u0627\u063a \u0627\u0644\u0628\u064a\u0626\u064a.<\/p>\n\n\n\n<p><strong>\u06334: \u0643\u064a\u0641 \u064a\u0645\u0643\u0646\u0646\u064a \u062a\u0642\u064a\u064a\u0645 \u0645\u0637\u0627\u0644\u0628\u0627\u062a \u201c\u062e\u0628\u0631\u0629 \u0627\u0644\u062a\u0639\u062f\u064a\u0646\u201d \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629\u061f<\/strong><br>\u062c: \u0627\u0637\u0644\u0628 \u0645\u0634\u0627\u0631\u064a\u0639 \u0645\u0631\u062c\u0639\u064a\u0629 \u0645\u062d\u062f\u062f\u0629 \u0645\u0639: \u0627\u0633\u0645 \u0627\u0644\u0645\u0646\u062c\u0645\u060c \u0648\u0646\u0648\u0639 \u0627\u0644\u062e\u0627\u0645\u060c \u0648\u0627\u0644\u0628\u064a\u0626\u0629 (\u0627\u0644\u0633\u0637\u062d\/\u0628\u0627\u0637\u0646 \u0627\u0644\u0623\u0631\u0636\u060c \u0648\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639\u060c \u0648\u0627\u0644\u0645\u0646\u0627\u062e)\u060c \u0648\u0633\u0646\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u060c \u0648\u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629\u060c \u0648\u0627\u0633\u0645 \u062c\u0647\u0629 \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0644\u0644\u062a\u062d\u0642\u0642. \u0642\u0645 \u0628\u0632\u064a\u0627\u0631\u0629 \u0627\u0644\u0645\u0648\u0642\u0639 \u0627\u0644\u0645\u0631\u062c\u0639\u064a \u0625\u0646 \u0623\u0645\u0643\u0646 - \u0631\u0627\u0642\u0628 \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0628\u0639\u062f \u0627\u0644\u062e\u062f\u0645\u0629. \u062a\u0639\u062a\u0628\u0631 \u0627\u0644\u0627\u062f\u0639\u0627\u0621\u0627\u062a \u0627\u0644\u0639\u0627\u0645\u0629 \u201c\u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0644\u062a\u0639\u062f\u064a\u0646\u201d \u0628\u062f\u0648\u0646 \u0645\u0631\u0627\u062c\u0639 \u064a\u0645\u0643\u0646 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646\u0647\u0627 \u0628\u0645\u062b\u0627\u0628\u0629 \u0639\u0644\u0627\u0645\u0627\u062a \u062d\u0645\u0631\u0627\u0621.<\/p>\n\n\n\n<p><strong>\u0627\u0644\u0633\u0624\u0627\u0644 5: \u0645\u0627 \u0647\u0648 \u0627\u0644\u0623\u0647\u0645 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629: \u0623\u0642\u0644 \u062a\u0643\u0644\u0641\u0629 \u0631\u0623\u0633\u0645\u0627\u0644\u064a\u0629 \u0623\u0645 \u0623\u0633\u0631\u0639 \u0648\u0642\u062a \u0644\u0644\u0625\u0635\u0644\u0627\u062d\u061f<\/strong><br>\u062c: \u064a\u0647\u064a\u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u0625\u0635\u0644\u0627\u062d \u0627\u0644\u0623\u0633\u0631\u0639 (MTTR) \u0639\u0644\u0649 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u062d\u064a\u062b \u064a\u0643\u0644\u0641 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 $50,000-500,000\/\u0633\u0627\u0639\u0629. \u0627\u062d\u0633\u0628 \u062a\u0643\u0644\u0641\u0629 \u0632\u0645\u0646 \u0627\u0644\u062a\u0639\u0637\u0644 \u00d7 \u0641\u0631\u0642 \u0648\u0642\u062a \u0627\u0644\u062a\u0639\u0637\u0644 (MTTR) \u0645\u0642\u0627\u0628\u0644 \u0641\u0631\u0642 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0631\u0623\u0633\u0645\u0627\u0644\u064a\u0629. \u0645\u062b\u0627\u0644: \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0645\u062a\u0627\u0632\u0629 $200,000 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629 $120,000 ($80 \u0623\u0644\u0641 \u0642\u0633\u0637)\u060c \u0644\u0643\u0646 \u0627\u0644\u0642\u0633\u0637 \u0644\u062f\u064a\u0647 2 \u0633\u0627\u0639\u0629 MTTR \u0645\u0642\u0627\u0628\u0644 8 \u0633\u0627\u0639\u0627\u062a (\u0641\u0631\u0642 6 \u0633\u0627\u0639\u0627\u062a). \u0625\u0630\u0627 \u0643\u0627\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0648\u0642\u0641 \u0639\u0646 \u0627\u0644\u0639\u0645\u0644 = $100K\/\u0633\u0627\u0639\u0629\u060c \u0641\u0625\u0646 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0648\u0627\u062d\u062f \u064a\u0648\u0641\u0631 6 \u00d7 $100K = $600K - \u0627\u0644\u0642\u0633\u0637 \u064a\u062f\u0641\u0639 \u062b\u0645\u0646\u0647 \u0641\u064a \u062d\u0627\u062f\u062b\u0629 \u0648\u0627\u062d\u062f\u0629.<\/p>\n\n\n\n<p><strong>\u06336: \u0647\u0644 \u064a\u0645\u0643\u0646 \u0644\u0644\u0645\u0635\u0646\u0639\u064a\u0646 \u0627\u0644\u0635\u064a\u0646\u064a\u064a\u0646 (XBRELE\u060c \u0625\u0644\u062e) \u062a\u0644\u0628\u064a\u0629 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0635\u0627\u0631\u0645\u0629\u061f<\/strong><br>\u062c: \u062a\u0633\u062a\u0648\u0641\u064a \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u064a\u0646\u064a\u0629 \u0645\u0646 \u0627\u0644\u062f\u0631\u062c\u0629 \u0627\u0644\u0623\u0648\u0644\u0649 (XBRELE\u060c CHINT\u060c \u0625\u0644\u062e) \u0645\u0639\u0627\u064a\u064a\u0631 IEC \u0648\u0644\u062f\u064a\u0647\u0627 \u0645\u062d\u0627\u0641\u0638 \u062a\u0639\u062f\u064a\u0646 \u0643\u0628\u064a\u0631\u0629\u060c \u062e\u0627\u0635\u0629 \u0641\u064a \u0622\u0633\u064a\u0627\/\u0623\u0641\u0631\u064a\u0642\u064a\u0627\/\u0623\u0645\u0631\u064a\u0643\u0627 \u0627\u0644\u0644\u0627\u062a\u064a\u0646\u064a\u0629. \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0647\u0648 \u0627\u0644\u062a\u062d\u0642\u0642: \u0627\u0637\u0644\u0628 \u062a\u0642\u0627\u0631\u064a\u0631 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0639\u062a\u0645\u062f\u0629 (\u0648\u0644\u064a\u0633 \u0645\u0639\u062a\u0645\u062f\u0629 \u0630\u0627\u062a\u064a\u064b\u0627)\u060c \u0648\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 (\u062a\u062d\u0642\u0642 \u0628\u0634\u0643\u0644 \u0645\u0633\u062a\u0642\u0644)\u060c \u0648\u0642\u0645 \u0628\u062a\u0642\u064a\u064a\u0645 \u0642\u062f\u0631\u0629 \u0627\u0644\u062e\u062f\u0645\u0629 \u0627\u0644\u0645\u062d\u0644\u064a\u0629. \u0648\u0642\u062f \u0636\u0627\u0642\u062a \u0627\u0644\u0641\u062c\u0648\u0629 \u0641\u064a \u0627\u0644\u062c\u0648\u062f\u0629 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a\u0629 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 - \u0648\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0628\u0631\u0631 \u0648\u0641\u0648\u0631\u0627\u062a \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629.<\/p>\n\n\n\n<p><strong>\u0633 7: \u0643\u0645 \u0645\u0631\u0629 \u064a\u062c\u0628 \u0623\u0646 \u062a\u062e\u0636\u0639 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0644\u0644\u0635\u064a\u0627\u0646\u0629 \u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629\u061f<\/strong><br>\u062c: \u0623\u0643\u062b\u0631 \u062a\u0648\u0627\u062a\u0631\u0627\u064b \u0628\u0633\u0628\u0628 \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0623\u0643\u062b\u0631 \u0642\u0633\u0648\u0629. \u0635\u0646\u0627\u0639\u064a \u0642\u064a\u0627\u0633\u064a: \u0641\u062d\u0635 \u0633\u0646\u0648\u064a. \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0627\u0644\u0633\u0637\u062d\u064a: \u0646\u0635\u0641 \u0633\u0646\u0648\u064a (\u062a\u0631\u0627\u0643\u0645 \u0627\u0644\u063a\u0628\u0627\u0631\u060c \u062a\u0623\u062b\u064a\u0631\u0627\u062a \u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632). \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636: \u0643\u0644 \u062b\u0644\u0627\u062b\u0629 \u0623\u0634\u0647\u0631 (\u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0627\u0644\u062c\u0648 \u0627\u0644\u0645\u0633\u0628\u0628 \u0644\u0644\u062a\u0622\u0643\u0644). \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0646\u0642\u0644\u0629: \u0634\u0647\u0631\u064a\u064b\u0627 \u0623\u0648 \u0643\u0644 10,000 \u0639\u0645\u0644\u064a\u0629 (\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0645\u062a\u0643\u0631\u0631 \u0644\u0644\u0639\u0645\u0644\u064a\u0627\u062a). \u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0643\u0644 \u062b\u0644\u0627\u062b\u0629 \u0623\u0634\u0647\u0631 \u0628\u063a\u0636 \u0627\u0644\u0646\u0638\u0631 \u0639\u0646 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 (\u0627\u0644\u062a\u0642\u0627\u0637 \u0627\u0644\u0628\u0642\u0639 \u0627\u0644\u0633\u0627\u062e\u0646\u0629 \u0627\u0644\u0646\u0627\u0645\u064a\u0629).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0648\u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ar\/products\/\">\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637<\/a> ? \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0648\u0627\u0644\u062d\u062f\u0648\u062f \u0648\u0645\u0644\u0627\u062d\u0638\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Mining environments destroy equipment that survives elsewhere. Dust penetration defeats standard IP ratings within months. Vibration from blasting and heavy equipment cracks epoxy insulators designed for static installations. Altitude at open-pit and underground mines reduces air-insulated component ratings by 10\u201320%. Temperature swings from -30\u00b0C surface conditions to +45\u00b0C underground stress thermal management systems designed for [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2583,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27,28],"tags":[],"class_list":["post-2582","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge","category-industry-news"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=2582"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2582\/revisions"}],"predecessor-version":[{"id":3617,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/2582\/revisions\/3617"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/2583"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=2582"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=2582"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=2582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}