{"id":3679,"date":"2026-04-28T00:00:00","date_gmt":"2026-04-28T00:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3679"},"modified":"2026-06-18T08:22:07","modified_gmt":"2026-06-18T08:22:07","slug":"control-cable-selection-mv-panels","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/control-cable-selection-mv-panels\/","title":{"rendered":"\u0627\u062e\u062a\u064a\u0627\u0631 \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0644\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637: \u0627\u0644\u062a\u062f\u0631\u064a\u0639\u060c \u0648\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u062d\u0631\u064a\u0642\u060c \u0648\u0627\u0644\u062a\u0648\u062c\u064a\u0647"},"content":{"rendered":"<h2>\u0645\u0642\u062f\u0645\u0629: \u0627\u0644\u062f\u0648\u0631 \u0627\u0644\u062d\u0627\u0633\u0645 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637<\/h2>\n<p>\u062a\u0639\u0645\u0644 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 (MV) \u0628\u0645\u062b\u0627\u0628\u0629 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u0639\u0635\u0628\u064a \u0644\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u062d\u064a\u062b \u062a\u0646\u0642\u0644 \u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u0647\u0627\u0645\u0629 \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u0642\u064a\u0627\u0633 \u0648\u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0648\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0623\u062a\u0645\u062a\u0629. \u0641\u064a \u062d\u064a\u0646 \u0623\u0646 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u062d\u0638\u0649 \u0628\u0627\u0644\u0627\u0647\u062a\u0645\u0627\u0645 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u0623\u062b\u0646\u0627\u0621 \u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0646\u0638\u0627\u0645\u060c \u0641\u0625\u0646 \u0627\u062e\u062a\u064a\u0627\u0631 \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u064a\u0624\u062b\u0631 \u0628\u0634\u0643\u0644 \u0645\u0628\u0627\u0634\u0631 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0646\u0638\u0627\u0645 \u0648\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0623\u0641\u0631\u0627\u062f \u0648\u0627\u0644\u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629. \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u0624\u062f\u064a \u0641\u0634\u0644 \u0643\u0627\u0628\u0644 \u062a\u062d\u0643\u0645 \u0648\u0627\u062d\u062f \u0625\u0644\u0649 \u062c\u0639\u0644 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u063a\u064a\u0631 \u0641\u0639\u0627\u0644\u0629\u060c \u0645\u0645\u0627 \u0642\u062f \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u062a\u0644\u0641 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0623\u0648 \u0623\u0639\u0637\u0627\u0644 \u0643\u0627\u0631\u062b\u064a\u0629.<\/p>\n<p>\u0628\u0639\u062f \u0623\u0646 \u0623\u0645\u0636\u064a\u062a \u0623\u0643\u062b\u0631 \u0645\u0646 \u062e\u0645\u0633\u0629 \u0639\u0634\u0631 \u0639\u0627\u0645\u064b\u0627 \u0641\u064a \u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0623\u062e\u0637\u0627\u0621 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0648\u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627 \u0641\u064a \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0644\u0644\u0645\u0631\u0627\u0641\u0642\u060c \u0634\u0647\u062f\u062a \u0639\u0646 \u0643\u062b\u0628 \u0643\u064a\u0641 \u0623\u0646 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u063a\u064a\u0631 \u0627\u0644\u0633\u0644\u064a\u0645 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u064a\u062e\u0644\u0642 \u0645\u0634\u0627\u0643\u0644 \u062e\u0628\u064a\u062b\u0629 \u062a\u0638\u0647\u0631 \u0628\u0639\u062f \u0623\u0634\u0647\u0631 \u0623\u0648 \u0633\u0646\u0648\u0627\u062a \u0645\u0646 \u0627\u0644\u062a\u0631\u0643\u064a\u0628. \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0627\u0644\u0630\u064a \u064a\u062a\u0633\u0628\u0628 \u0641\u064a \u0631\u062d\u0644\u0627\u062a \u0645\u0631\u062d\u0644 \u0645\u0632\u0639\u062c\u0629\u060c \u0648\u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u062a\u0636\u0631\u0631\u0629 \u0645\u0646 \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u0627\u0644\u062a\u064a \u062a\u0646\u0634\u0631 \u0627\u0644\u0644\u0647\u0628 \u0628\u064a\u0646 \u0627\u0644\u0645\u0642\u0635\u0648\u0631\u0627\u062a\u060c \u0648\u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0633\u064a\u0626\u0629 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062a\u064a \u062a\u062a\u0633\u0628\u0628 \u0641\u064a \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0645\u062a\u0642\u0637\u0639\u0629 - \u0647\u0630\u0647 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u062a\u0634\u062a\u0631\u0643 \u0641\u064a \u062c\u0630\u0648\u0631 \u0645\u0634\u062a\u0631\u0643\u0629: \u0639\u062f\u0645 \u0627\u0644\u0627\u0647\u062a\u0645\u0627\u0645 \u0627\u0644\u0643\u0627\u0641\u064a \u0628\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u062b\u0646\u0627\u0621 \u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u062a\u0635\u0645\u064a\u0645.<\/p>\n<p>\u064a\u0639\u0627\u0644\u062c \u0647\u0630\u0627 \u0627\u0644\u062f\u0644\u064a\u0644 \u0627\u0644\u0634\u0627\u0645\u0644 \u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0645\u0635\u0646\u0641 \u0645\u0646 1 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0625\u0644\u0649 52 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a\u060c \u0648\u064a\u063a\u0637\u064a \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u062f\u0631\u064a\u0639\u060c \u0648\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0623\u062f\u0627\u0621 \u0627\u0644\u062d\u0631\u064a\u0642\u060c \u0648\u0623\u0641\u0636\u0644 \u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0627\u0644\u062a\u0648\u062c\u064a\u0647\u060c \u0648\u062a\u0642\u0646\u064a\u0627\u062a \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062a\u064a \u062a\u0636\u0645\u0646 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0646\u0638\u0627\u0645 \u0639\u0644\u0649 \u0627\u0644\u0645\u062f\u0649 \u0627\u0644\u0637\u0648\u064a\u0644.<\/p>\n<h2>\u0645\u0635\u0641\u0648\u0641\u0629 \u0627\u0644\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0633\u0631\u064a\u0639 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0629 MV<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0646\u0648\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629<\/th>\n<th>\u0647\u064a\u0643\u0644 \u0627\u0644\u0643\u0627\u0628\u0644 \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647<\/th>\n<th>\u0627\u0644\u0648\u062c\u0628\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u062a\u062d\u0633\u064a\u0646 \u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0628\u062d\u062b\/\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0648\u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/td>\n<td>\u0646\u062d\u0627\u0633 \u0645\u062c\u062f\u0648\u0644 \u0645\u0646 \u0627\u0644\u0646\u062d\u0627\u0633\u060c \u0648\u062f\u0631\u0639 \u0645\u062c\u062f\u0648\u0644 \u0628\u0627\u0644\u0643\u0627\u0645\u0644\u060c \u0648\u0623\u0646\u0648\u064a\u0629 \u0645\u062d\u062f\u062f\u0629 \u0628\u0648\u0636\u0648\u062d<\/td>\n<td>\u0625\u0639\u0637\u0627\u0621 \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u062f\u0642\u0629 \u0627\u0644\u0639\u0628\u0621 \u0648\u062a\u062d\u0645\u0644 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0648\u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u062f\u0631\u0639.<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u0639\u062b\u0631\u060c \u0648\u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0648\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u064a<\/td>\n<td>2.5 \u0645\u0645\u00b2 \u0646\u062d\u0627\u0633 \u0645\u062c\u062f\u0648\u0644 2.5 \u0645\u0645\u00b2 \u0645\u0639 \u0639\u0632\u0644 \u0642\u0648\u064a \u0648\u062d\u0644\u0642\u0627\u062a<\/td>\n<td>\u0627\u0644\u062d\u062c\u0645 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0644\u062a\u062f\u0641\u0642 \u0627\u0644\u0645\u0644\u0641\u060c \u0648\u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0627\u0644\u0645\u062a\u0627\u0646\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629.<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u0648\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0627\u0633\u062a\u0634\u0639\u0627\u0631<\/td>\n<td>\u0623\u0632\u0648\u0627\u062c \u0623\u0648 \u062b\u0644\u0627\u062b\u064a\u0629 \u0645\u062d\u0645\u064a\u0629 \u0628\u0634\u0643\u0644 \u0641\u0631\u062f\u064a \u0645\u0639 \u062a\u0648\u062c\u064a\u0647 \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u062a\u0634\u0648\u064a\u0634<\/td>\n<td>\u0627\u0641\u0635\u0644 \u0639\u0646 \u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0639\u0627\u0628\u0631\u064a\u0646 \u0648\u0627\u0644\u062f\u0631\u0648\u0639 \u0627\u0644\u0623\u0631\u0636\u064a\u0629 \u0639\u0645\u062f\u0627\u064b.<\/td>\n<\/tr>\n<tr>\n<td>\u0625\u0634\u0627\u0631\u0627\u062a Ethernet \u0648 RS-485 \u0648 IEC 61850<\/td>\n<td>\u0643\u0627\u0628\u0644 \u0627\u062a\u0635\u0627\u0644 \u0630\u0648 \u0645\u0642\u0627\u0648\u0645\u0629 \u0645\u062d\u0643\u0648\u0645\u0629 \u0645\u0639 \u0625\u0646\u0647\u0627\u0621 EMC<\/td>\n<td>\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u062f\u0631\u0639 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u063a\u062f\u062f \u0648\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0648\u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison.webp\" alt=\"\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u0645\u0642\u0637\u0639 \u0627\u0644\u0639\u0631\u0636\u064a \u0644\u062f\u0631\u0639 \u0627\u0644\u0631\u0642\u0627\u0642\u0629\u060c \u0648\u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u0645\u0636\u0641\u0648\u0631\u060c \u0648\u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u0641\u0631\u062f\u064a \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u0643\u0644\u064a \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637\" class=\"wp-image-3675\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u0645\u0642\u0627\u0637\u0639 \u0627\u0644\u0639\u0631\u0636\u064a\u0629 \u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u0631\u0642\u0627\u0626\u0642 \u0648\u0627\u0644\u0636\u0641\u064a\u0631\u0629 \u0648\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0627\u0644\u0645\u062f\u0645\u062c\u0629 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0641\u064a \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637.<\/figcaption><\/figure>\n<h2>\u0641\u0647\u0645 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u062a\u0637\u0628\u064a\u0642\u0627\u062a\u0647<\/h2>\n<h3>\u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a<\/h3>\n<p>\u062a\u062d\u0645\u0644 \u0643\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0627\u062a MV \u0623\u0646\u0648\u0627\u0639\u0627\u064b \u0645\u062e\u062a\u0644\u0641\u0629 \u0645\u0646 \u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a\u060c \u0648\u064a\u062a\u0637\u0644\u0628 \u0643\u0644 \u0645\u0646\u0647\u0627 \u062e\u0635\u0627\u0626\u0635 \u0643\u0627\u0628\u0644 \u0645\u062d\u062f\u062f\u0629:<\/p>\n<p><strong>\u0625\u0634\u0627\u0631\u0627\u062a \u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u0645\u0633\u062a\u0648\u0649<\/strong> (\u062d\u0644\u0642\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 4-20mA\u060c \u0648\u062f\u0648\u0627\u0626\u0631 RTD\u060c \u0648\u0645\u062e\u0631\u062c\u0627\u062a \u0627\u0644\u0645\u0632\u062f\u0648\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629) \u062a\u062a\u0637\u0644\u0628 \u0645\u0646\u0627\u0639\u0629 \u0641\u0627\u0626\u0642\u0629 \u0636\u062f \u0627\u0644\u0636\u0648\u0636\u0627\u0621 \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u062b\u0627\u0628\u062a\u0629 \u0644\u0644\u0645\u0648\u0635\u0644. \u062a\u0631\u0628\u0637 \u0647\u0630\u0647 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0639\u0627\u062f\u0629\u064b \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631\u060c \u0648\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0645\u0633\u062a\u0634\u0639\u0631\u0627\u062a \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0623\u062c\u0647\u0632\u0629 \u0625\u0631\u0633\u0627\u0644 \u0627\u0644\u0636\u063a\u0637 \u0628\u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0623\u0646\u0638\u0645\u0629 SCADA.<\/p>\n<p><strong>\u0625\u0634\u0627\u0631\u0627\u062a \u0631\u0642\u0645\u064a\u0629<\/strong> (\u0645\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a\u060c \u0648\u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629\u060c \u0648\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629\u060c \u0648\u0645\u0624\u0634\u0631\u0627\u062a \u0627\u0644\u0645\u0648\u0636\u0639) \u062a\u0639\u0645\u0644 \u0628\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u062c\u0647\u062f \u0623\u0639\u0644\u0649 (24-125 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0623\u0648 110-240 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f) \u0645\u0639 \u0642\u062f\u0631\u0629 \u0623\u0643\u0628\u0631 \u0639\u0644\u0649 \u062a\u062d\u0645\u0644 \u0627\u0644\u0636\u0648\u0636\u0627\u0621. \u0648\u0645\u0639 \u0630\u0644\u0643\u060c \u062a\u0635\u0628\u062d \u0633\u0639\u0629 \u0627\u0644\u0643\u0627\u0628\u0644 \u0623\u0645\u0631\u064b\u0627 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0644\u0645\u0633\u0627\u0641\u0627\u062a \u0627\u0644\u0623\u0637\u0648\u0644 \u0627\u0644\u062a\u064a \u062a\u062a\u062c\u0627\u0648\u0632 100 \u0645\u062a\u0631\u060c \u062e\u0627\u0635\u0629\u064b \u0645\u0639 \u0645\u062f\u062e\u0644\u0627\u062a \u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0635\u0644\u0628\u0629.<\/p>\n<p><strong>\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a<\/strong> (Ethernet\u060c \u0648 RS-485 \u0627\u0644\u062a\u0633\u0644\u0633\u0644\u064a\u0629\u060c \u0648 IEC 61850 GOOSE \u0644\u0644\u0631\u0633\u0627\u0626\u0644) \u062a\u062a\u0637\u0644\u0628 \u062e\u0635\u0627\u0626\u0635 \u0645\u0642\u0627\u0648\u0645\u0629 \u0645\u0636\u0628\u0648\u0637\u0629 \u0648\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u062a\u062f\u0631\u064a\u0639 \u0645\u062d\u062f\u062f\u0629 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0639\u0646\u062f \u0633\u0631\u0639\u0627\u062a \u0646\u0642\u0644 \u062a\u0635\u0644 \u0625\u0644\u0649 100 \u0645\u064a\u063a\u0627\u0628\u062a \u0641\u064a \u0627\u0644\u062b\u0627\u0646\u064a\u0629 \u0623\u0648 \u0623\u0639\u0644\u0649.<\/p>\n<h3>\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a \u062a\u062d\u062c\u064a\u0645 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a<\/h3>\n<p>\u064a\u062a\u062c\u0627\u0648\u0632 \u062a\u062d\u062f\u064a\u062f \u062d\u062c\u0645 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u062c\u0631\u062f \u062d\u0633\u0627\u0628\u0627\u062a \u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u062d\u0645\u0644 \u0627\u0644\u062a\u064a\u0627\u0631. \u0648\u062a\u0634\u0645\u0644 \u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0645\u0627 \u064a\u0644\u064a:<\/p>\n<ul>\n<li><strong>\u0642\u064a\u0648\u062f \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f<\/strong>: \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0639\u0627\u062f\u0629\u064b \u0623\u0642\u0644 \u0645\u0646 1% \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u062f\u0642\u0629 \u0627\u0644\u0639\u0628\u0621<\/li>\n<li><strong>\u0635\u0645\u0648\u062f \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629<\/strong>: \u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u062d\u0645\u0644 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0648\u0635\u0644\u0629 \u0644\u0644\u062b\u0648\u0627\u0646\u064a \u0627\u0644\u0645\u0642\u0637\u0639\u064a\u0629 \u0627\u0644\u0645\u0642\u0637\u0639\u064a\u0629 \u0627\u0644\u062a\u0623\u062b\u064a\u0631\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629 \u0623\u062b\u0646\u0627\u0621 \u0638\u0631\u0648\u0641 \u0627\u0644\u0639\u0637\u0644<\/li>\n<li><strong>\u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629<\/strong>: \u064a\u0636\u0645\u0646 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0623\u062d\u062c\u0627\u0645 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a (\u0639\u0627\u062f\u0629\u064b 1.5 \u0645\u0645\u00b2 \u0623\u0648 2.5 \u0645\u0645\u00b2) \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0627\u0644\u0643\u0627\u0641\u064a\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable.webp\" alt=\"\u0631\u0633\u0645 \u0628\u064a\u0627\u0646\u064a \u0645\u062a\u062f\u0631\u062c \u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u062a\u0635\u0646\u064a\u0641 IEC \u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062d\u0631\u064a\u0642 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 IEC 60332 \u0648 IEC 61034 \u0648 IEC 60754 \u0648 IEC 60331\" class=\"wp-image-3676\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0627\u0644\u062a\u0633\u0644\u0633\u0644 \u0627\u0644\u0647\u0631\u0645\u064a \u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0623\u062f\u0627\u0621 \u0627\u0644\u062d\u0631\u0627\u0626\u0642 IEC \u0627\u0644\u0645\u0637\u0628\u0642\u0629 \u0639\u0644\u0649 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062b\u0628\u062a\u0629 \u0641\u064a \u063a\u0631\u0641 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0645\u063a\u0644\u0642\u0629.<\/figcaption><\/figure>\n<h2>\u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a\u0627\u062a \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0644\u0644\u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a<\/h2>\n<h3>\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637<\/h3>\n<p>\u062a\u0645\u062b\u0644 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0628\u064a\u0626\u0629 \u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629 \u0635\u0639\u0628\u0629. \u0648\u062a\u0634\u0645\u0644 \u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0645\u0627 \u064a\u0644\u064a:<\/p>\n<p><strong>\u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0630\u064a \u062a\u0645 \u0625\u062c\u0631\u0627\u0624\u0647<\/strong> \u062a\u0646\u0634\u0623 \u0645\u0646 \u062a\u0648\u0627\u0641\u0642\u064a\u0627\u062a \u062a\u0631\u062f\u062f \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0648\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0639\u0627\u0628\u0631 \u0644\u0644\u062a\u0631\u062f\u062f\u0627\u062a\u060c \u0648\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0639\u0627\u0628\u0631 \u0644\u0644\u062a\u0631\u062f\u062f\u0627\u062a\u060c \u0648\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0623\u0631\u0636\u064a \u0623\u062b\u0646\u0627\u0621 \u0638\u0631\u0648\u0641 \u0627\u0644\u0639\u0637\u0644. \u062a\u0648\u0644\u062f \u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a\u060c \u0648\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0629\u060c \u0648\u062a\u0628\u062f\u064a\u0644 \u0628\u0646\u0643 \u0627\u0644\u0645\u0643\u062b\u0641\u0627\u062a \u0636\u0648\u0636\u0627\u0621 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u0645\u0648\u0635\u0644\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u062a\u0642\u062a\u0631\u0646 \u0628\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0633\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u0645\u0634\u062a\u0631\u0643\u0629.<\/p>\n<p><strong>\u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0625\u0634\u0639\u0627\u0639\u064a<\/strong> \u062a\u0646\u0628\u062b\u0642 \u0645\u0646 \u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u0646\u0627\u0642\u0644 \u0627\u0644\u062a\u064a \u062a\u062d\u0645\u0644 \u062a\u064a\u0627\u0631\u0627\u062a \u0639\u0627\u0644\u064a\u0629\u060c \u0648\u0623\u062d\u062f\u0627\u062b \u0627\u0644\u0648\u0645\u064a\u0636 \u0627\u0644\u0642\u0648\u0633\u064a\u060c \u0648\u0646\u0634\u0627\u0637 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a\u060c \u0648\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u062a\u0631\u062f\u062f\u0627\u062a \u0627\u0644\u0631\u0627\u062f\u064a\u0648\u064a\u0629 \u0627\u0644\u0642\u0631\u064a\u0628\u0629. \u064a\u0645\u0643\u0646 \u0644\u0644\u0645\u062c\u0627\u0644\u0627\u062a \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u0628\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0646\u0627\u0642\u0644 \u0623\u0646 \u062a\u0633\u062a\u062d\u062b \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0641\u064a \u062d\u0644\u0642\u0627\u062a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0645\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u0639\u062a\u0628\u0627\u062a \u062a\u0634\u063a\u064a\u0644 \u0645\u0631\u062d\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629.<\/p>\n<p><strong>\u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0643\u0647\u0631\u0648\u0633\u062a\u0627\u062a\u064a\u0643\u064a<\/strong> \u0627\u0644\u0627\u0642\u062a\u0631\u0627\u0646 \u0628\u0627\u0644\u0633\u0639\u0629 \u0645\u0646 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a \u0625\u0644\u0649 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062c\u0627\u0648\u0631\u0629\u060c \u0648\u0647\u0648 \u0645\u0627 \u064a\u0645\u062b\u0644 \u0645\u0634\u0643\u0644\u0629 \u062e\u0627\u0635\u0629 \u0641\u064a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0627\u0644\u063a\u0627\u0632 (GIS) \u062d\u064a\u062b \u062a\u0645\u0631 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u0642\u0631\u0628 \u0645\u0646 \u0627\u0644\u0645\u0642\u0635\u0648\u0631\u0627\u062a \u0627\u0644\u0645\u0645\u0644\u0648\u0621\u0629 \u0628\u0640 SF6.<\/p>\n<h3>\u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u062f\u0631\u0648\u0639 \u0648\u062a\u0637\u0628\u064a\u0642\u0627\u062a\u0647\u0627<\/h3>\n<p><strong>\u062f\u0631\u0648\u0639 \u0631\u0642\u0627\u0626\u0642 \u0645\u0639\u062f\u0646\u064a\u0629<\/strong> (\u0635\u0641\u0627\u0626\u062d \u0645\u0646 \u0627\u0644\u0623\u0644\u0648\u0645\u0646\u064a\u0648\u0645 \u0648\u0627\u0644\u0628\u0648\u0644\u064a\u0633\u062a\u0631) \u062a\u0648\u0641\u0631 \u062a\u063a\u0637\u064a\u0629 100% \u0648\u062a\u0648\u0647\u064a\u0646\u064b\u0627 \u0645\u0645\u062a\u0627\u0632\u064b\u0627 \u0639\u0627\u0644\u064a \u0627\u0644\u062a\u0631\u062f\u062f \u0623\u0639\u0644\u0649 \u0645\u0646 1 \u0645\u064a\u062c\u0627\u0647\u0631\u062a\u0632. \u064a\u0642\u0644\u0644 \u0627\u0644\u0647\u064a\u0643\u0644 \u0627\u0644\u0631\u0642\u064a\u0642 \u0645\u0646 \u0642\u0637\u0631 \u0627\u0644\u0643\u0627\u0628\u0644 \u0648\u0644\u0643\u0646\u0647 \u064a\u0648\u0641\u0631 \u0631\u0641\u0636\u064b\u0627 \u0645\u062d\u062f\u0648\u062f\u064b\u0627 \u0644\u0644\u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u062a\u0631\u062f\u062f. \u062a\u0639\u0645\u0644 \u0627\u0644\u062f\u0631\u0648\u0639 \u0627\u0644\u0631\u0642\u064a\u0642\u0629 \u0639\u0644\u0649 \u0627\u0644\u0646\u062d\u0648 \u0627\u0644\u0623\u0645\u062b\u0644 \u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0648\u0627\u0644\u0645\u062f\u062e\u0644\u0627\u062a \u0627\u0644\u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629.<\/p>\n<p><strong>\u062f\u0631\u0648\u0639 \u0645\u0636\u0641\u0631\u0629<\/strong> (\u062c\u062f\u064a\u0644\u0629 \u0646\u062d\u0627\u0633\u064a\u0629 \u0645\u0639\u0644\u0628\u0629\u060c \u062a\u063a\u0637\u064a\u0629 85-95% \u0639\u0627\u062f\u0629\u064b) \u062a\u0648\u0641\u0631 \u062a\u062f\u0631\u064a\u0639\u064b\u0627 \u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u064b\u0627 \u0641\u0627\u0626\u0642\u064b\u0627 \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u062a\u0631\u062f\u062f \u0648\u0645\u0631\u0648\u0646\u0629 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0623\u0641\u0636\u0644 \u0645\u0646 \u0628\u062f\u0627\u0626\u0644 \u0627\u0644\u0631\u0642\u0627\u0626\u0642 \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629. \u0625\u0646 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0646\u0642\u0644 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u0639\u0646\u062f \u0627\u0644\u062a\u0631\u062f\u062f\u0627\u062a \u0627\u0644\u0623\u0642\u0644 \u0645\u0646 1 \u0645\u064a\u062c\u0627\u0647\u0631\u062a\u0632 \u062a\u062c\u0639\u0644 \u0627\u0644\u062f\u0631\u0648\u0639 \u0627\u0644\u0645\u0636\u0641\u0631\u0629 \u0645\u0641\u0636\u0644\u0629 \u0644\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628\/\u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0648\u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629.<\/p>\n<p><strong>\u0627\u0644\u062f\u0631\u0648\u0639 \u0627\u0644\u0645\u062f\u0645\u062c\u0629<\/strong> (\u0631\u0642\u0627\u0626\u0642 \u0645\u0639\u062f\u0646\u064a\u0629 \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u062c\u062f\u064a\u0644\u0629) \u062a\u0648\u0641\u0631 \u062d\u0645\u0627\u064a\u0629 \u0639\u0631\u064a\u0636\u0629 \u0627\u0644\u0646\u0637\u0627\u0642 \u0639\u0628\u0631 \u0637\u064a\u0641 \u0627\u0644\u062a\u0631\u062f\u062f. \u0639\u0644\u0649 \u0627\u0644\u0631\u063a\u0645 \u0645\u0646 \u0623\u0646 \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0627\u0644\u0645\u0631\u0643\u0628 \u0623\u0643\u062b\u0631 \u062a\u0643\u0644\u0641\u0629\u060c \u0625\u0644\u0627 \u0623\u0646\u0647 \u064a\u062b\u0628\u062a \u0623\u0646\u0647 \u0636\u0631\u0648\u0631\u064a \u0644\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u0627\u0644\u062d\u0633\u0627\u0633\u0629 \u0641\u064a \u0627\u0644\u0628\u064a\u0626\u0627\u062a \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062f\u0627\u062e\u0644\u060c \u0645\u062b\u0644 \u0623\u0646\u0638\u0645\u0629 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a \u0627\u0644\u062a\u064a \u062a\u0639\u0645\u0644 \u0628\u0627\u0644\u0642\u0631\u0628 \u0645\u0646 \u0646\u0627\u0642\u0644\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637.<\/p>\n<p><strong>\u0623\u0632\u0648\u0627\u062c\/\u062b\u0644\u0627\u062b\u064a\u0627\u062a \u0645\u062d\u0645\u064a\u0629 \u0628\u0634\u0643\u0644 \u0641\u0631\u062f\u064a<\/strong> \u0645\u0646\u0639 \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0628\u064a\u0646 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u062f\u0627\u062e\u0644 \u0627\u0644\u0643\u0627\u0628\u0644 \u0646\u0641\u0633\u0647\u060c \u0648\u0647\u0648 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0639\u0646\u062f \u0645\u0632\u062c \u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u0648\u0627\u0644\u0631\u0642\u0645\u064a\u0629. \u062a\u0633\u0645\u062d \u0647\u0630\u0647 \u0627\u0644\u0628\u0646\u064a\u0629 \u0644\u0623\u0646\u0648\u0627\u0639 \u0645\u062a\u0639\u062f\u062f\u0629 \u0645\u0646 \u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0628\u0645\u0634\u0627\u0631\u0643\u0629 \u0645\u0633\u0627\u0631 \u0643\u0627\u0628\u0644 \u0645\u0634\u062a\u0631\u0643 \u0645\u0639 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0625\u0634\u0627\u0631\u0629.<\/p>\n<h3>\u062a\u0642\u0646\u064a\u0627\u062a \u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u062f\u0631\u0639<\/h3>\n<p>\u062a\u062b\u064a\u0631 \u0641\u0644\u0633\u0641\u0629 \u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u062f\u0631\u0648\u0639 \u062c\u062f\u0644\u0627\u064b \u0643\u0628\u064a\u0631\u0627\u064b \u0628\u064a\u0646 \u0627\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646. \u0648\u0627\u0633\u062a\u0646\u0627\u062f\u0627\u064b \u0625\u0644\u0649 \u0642\u064a\u0627\u0633\u0627\u062a \u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0648\u0627\u0633\u0639\u0629 \u0627\u0644\u0646\u0637\u0627\u0642 \u0648\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0635\u0646\u0627\u0639\u0629 (IEEE 1143\u060c IEC 62271-1)\u060c \u0623\u0648\u0635\u064a \u0628\u0627\u0644\u0646\u0647\u062c \u0627\u0644\u062a\u0627\u0644\u064a:<\/p>\n<p><strong>\u062a\u0623\u0631\u064a\u0636 \u0623\u062d\u0627\u062f\u064a \u0627\u0644\u0646\u0642\u0637\u0629<\/strong> \u0641\u064a \u0637\u0631\u0641 \u0627\u0644\u0644\u0648\u062d\u0629 \u064a\u0645\u0646\u0639 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062f\u0627\u0626\u0631\u064a\u0629 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u062f\u0631\u0639\u060c \u0648\u0647\u0648 \u0645\u062b\u0627\u0644\u064a \u0644\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u062d\u064a\u062b \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u062d\u062b\u0629 \u0625\u0644\u0649 \u062d\u062f\u0648\u062b \u0623\u062e\u0637\u0627\u0621 \u0641\u064a \u0627\u0644\u0642\u064a\u0627\u0633. \u062a\u062a\u0637\u0644\u0628 \u0647\u0630\u0647 \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0639\u0632\u0644 \u0645\u0646\u0627\u0633\u0628 \u0644\u0644\u062f\u0631\u0639 \u0641\u064a \u0627\u0644\u0637\u0631\u0641 \u0627\u0644\u0628\u0639\u064a\u062f.<\/p>\n<p><strong>\u062a\u0623\u0631\u064a\u0636 \u0645\u062a\u0639\u062f\u062f \u0627\u0644\u0646\u0642\u0627\u0637<\/strong> \u064a\u0648\u0641\u0631 \u0631\u0641\u0636\u064b\u0627 \u0641\u0627\u0626\u0642\u064b\u0627 \u0644\u0644\u0636\u0648\u0636\u0627\u0621 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u0645\u0646 \u062e\u0644\u0627\u0644 \u0625\u0646\u0634\u0627\u0621 \u0645\u0633\u0627\u0631 \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0623\u0631\u0636 \u0641\u064a \u0645\u0648\u0627\u0642\u0639 \u0645\u062a\u0639\u062f\u062f\u0629. \u064a\u0646\u0627\u0633\u0628 \u0647\u0630\u0627 \u0627\u0644\u0646\u0647\u062c \u062f\u0627\u0631\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0627\u0644\u0631\u0642\u0645\u064a\u0629 \u0648\u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0645\u062b\u0644 \u0641\u064a\u0647\u0627 \u0627\u0644\u0639\u0627\u0628\u0631\u0648\u0646 \u0627\u0644\u0646\u0627\u062c\u0645\u0648\u0646 \u0639\u0646 \u0627\u0644\u0635\u0648\u0627\u0639\u0642 \u0645\u062e\u0627\u0648\u0641.<\/p>\n<p><strong>\u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u0647\u062c\u064a\u0646<\/strong> \u064a\u0648\u0635\u0644 \u0627\u0644\u062f\u0631\u0648\u0639 \u0645\u0628\u0627\u0634\u0631\u0629 \u0641\u064a \u0637\u0631\u0641 \u0627\u0644\u0644\u0648\u062d\u0629 \u0645\u0628\u0627\u0634\u0631\u0629 \u0648\u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0643\u062b\u0641\u0627\u062a \u0627\u0644\u0627\u0644\u062a\u0641\u0627\u0641\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062f\u062f (\u0639\u0627\u062f\u0629\u064b 10-100nF) \u0641\u064a \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0628\u0639\u064a\u062f\u0629. \u064a\u0645\u0646\u0639 \u0647\u0630\u0627 \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062f\u0627\u0626\u0631\u064a\u0629 \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u0645\u0639 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0639\u0627\u0644\u064a \u0627\u0644\u062a\u0631\u062f\u062f.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation.webp\" alt=\"\u0645\u062e\u0637\u0637 \u062a\u062e\u0637\u064a\u0637 \u0635\u064a\u0646\u064a\u0629 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u064a\u0648\u0636\u062d \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0644\u0645\u0633\u0627\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0628\u064a\u0646 \u0637\u0627\u0642\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0648\u0637\u0627\u0642\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636 \u0648\u0635\u0648\u0627\u0646\u064a \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645\" class=\"wp-image-3677\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0645\u0633\u0627\u0641\u0627\u062a \u0641\u0635\u0644 \u0639\u0644\u0628\u0629 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u0648\u0635\u0649 \u0628\u0647\u0627 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062a\u064a \u064a\u062a\u0645 \u062a\u0648\u062c\u064a\u0647\u0647\u0627 \u0625\u0644\u0649 \u062c\u0627\u0646\u0628 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0641\u064a \u063a\u0631\u0641 \u0645\u0641\u0627\u062a\u064a\u062d MV.<\/figcaption><\/figure>\n<h2>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0648\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0623\u062f\u0627\u0621 \u0641\u064a \u0645\u0643\u0627\u0641\u062d\u0629 \u0627\u0644\u062d\u0631\u0627\u0626\u0642<\/h2>\n<h3>\u0641\u0647\u0645 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u062d\u0631\u0627\u0626\u0642<\/h3>\n<p>\u064a\u0634\u062a\u0645\u0644 \u0623\u062f\u0627\u0621 \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u0639\u0644\u0649 \u062e\u0635\u0627\u0626\u0635 \u0645\u062a\u0639\u062f\u062f\u0629\u060c \u064a\u062a\u0645 \u062a\u0642\u064a\u064a\u0645 \u0643\u0644 \u0645\u0646\u0647\u0627 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0645\u062d\u062f\u062f\u0629:<\/p>\n<p><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u0644\u0647\u0628<\/strong> \u062a\u0642\u064a\u0633 \u0633\u0644\u0633\u0644\u0629 IEC 60332 (IEC 60332) \u0645\u064a\u0644 \u0627\u0644\u0643\u0627\u0628\u0644 \u0644\u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u062d\u0631\u064a\u0642 \u0639\u0644\u0649 \u0637\u0648\u0644 \u0637\u0648\u0644\u0647. \u062a\u062e\u062a\u0628\u0631 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 60332-1 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \u0641\u064a \u0638\u0631\u0648\u0641 \u0627\u0644\u0644\u0647\u0628 \u0627\u0644\u0635\u063a\u064a\u0631\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0642\u0648\u0645 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 IEC 60332-3 \u0628\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u062c\u0645\u0639\u0629 \u0627\u0644\u062a\u064a \u062a\u0645\u062b\u0644 \u0643\u062b\u0627\u0641\u0627\u062a \u062a\u0631\u0643\u064a\u0628 \u0648\u0627\u0642\u0639\u064a\u0629. \u062a\u062d\u062f \u0627\u0644\u0641\u0626\u0629 A (\u0623\u0639\u0644\u0649 \u0623\u062f\u0627\u0621) \u0645\u0646 \u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u0644\u0647\u0628 \u0625\u0644\u0649 \u0623\u0642\u0644 \u0645\u0646 2.5 \u0645\u062a\u0631 \u0639\u0644\u0649 \u0639\u064a\u0646\u0629 \u0637\u0648\u0644\u0647\u0627 3.5 \u0645\u062a\u0631.<\/p>\n<p><strong>\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062d\u0631\u0627\u0626\u0642<\/strong> (IEC 60331) \u064a\u062d\u062f\u062f \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0639\u0631\u0636 \u0644\u0644\u062d\u0631\u064a\u0642. \u062a\u0633\u062a\u0645\u0631 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062c\u062a\u0627\u0632 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u064a \u0627\u0644\u0639\u0645\u0644 \u0628\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 \u0623\u062b\u0646\u0627\u0621 \u062a\u0639\u0631\u0636\u0647\u0627 \u0644\u0644\u0647\u0628 750 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0644\u0641\u062a\u0631\u0627\u062a \u0645\u062d\u062f\u062f\u0629 - \u0639\u0627\u062f\u0629\u064b 90 \u0623\u0648 120 \u062f\u0642\u064a\u0642\u0629 \u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062d\u0631\u062c\u0629.<\/p>\n<p><strong>\u0643\u062b\u0627\u0641\u0629 \u0627\u0644\u062f\u062e\u0627\u0646<\/strong> (IEC 61034) \u062a\u062d\u062f\u062f \u0645\u062f\u0649 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0631\u0624\u064a\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u062d\u062a\u0631\u0627\u0642 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a. \u062a\u062d\u0627\u0641\u0638 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u062f\u062e\u0627\u0646 \u0639\u0644\u0649 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0646\u0641\u0627\u0630\u064a\u0629 \u0627\u0644\u0636\u0648\u0621 60%\u060c \u0648\u0647\u0648 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0625\u062e\u0644\u0627\u0621 \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u0631\u062c\u0627\u0644 \u0627\u0644\u0625\u0637\u0641\u0627\u0621.<\/p>\n<p><strong>\u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0647\u0627\u0644\u0648\u062c\u064a\u0646 \u0648\u0627\u0646\u0628\u0639\u0627\u062b \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u062d\u0645\u0636\u064a\u0629<\/strong> (IEC 60754) \u062a\u0624\u062b\u0631 \u0639\u0644\u0649 \u0643\u0644 \u0645\u0646 \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0628\u0634\u0631\u064a\u0629 \u0648\u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a. \u062a\u0646\u062a\u062c \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u062f\u062e\u0627\u0646 \u0627\u0644\u062e\u0627\u0644\u064a\u0629 \u0645\u0646 \u0627\u0644\u0647\u0627\u0644\u0648\u062c\u064a\u0646 (LSZH) \u0646\u0648\u0627\u062a\u062c \u0627\u062d\u062a\u0631\u0627\u0642 \u063a\u064a\u0631 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0622\u0643\u0644\u060c \u0645\u0645\u0627 \u064a\u062d\u0645\u064a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0629 \u0627\u0644\u062d\u0633\u0627\u0633\u0629 \u0645\u0646 \u062a\u0644\u0641 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u062d\u0645\u0636\u064a\u0629.<\/p>\n<h3>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062d\u0631\u064a\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/h3>\n<p>\u062a\u062a\u0637\u0644\u0628 \u0628\u064a\u0626\u0627\u062a \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0645\u062e\u062a\u0644\u0641\u0629 \u0645\u0646 \u0623\u062f\u0627\u0621 \u0627\u0644\u062d\u0631\u0627\u0626\u0642:<\/p>\n<p><strong>\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0627\u0644\u0641\u0631\u0639\u064a\u0629<\/strong> \u062a\u062a\u0637\u0644\u0628 \u0639\u0627\u062f\u0629\u064b \u0643\u0627\u0628\u0644\u0627\u062a \u0645\u062b\u0628\u0637\u0629 \u0644\u0644\u0647\u0628 \u062a\u0641\u064a \u0628\u0627\u0644\u0641\u0626\u0629 C \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 IEC 60332-3 \u0643\u062d\u062f \u0623\u062f\u0646\u0649. \u0642\u062f \u062a\u0633\u0645\u062d \u0646\u0642\u0627\u0637 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 \u0628\u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0627\u0644\u0645\u062b\u0628\u0637\u0629 \u0644\u0644\u0647\u0628 \u0646\u0638\u0631\u0627\u064b \u0644\u0644\u062a\u0647\u0648\u064a\u0629 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0648\u062a\u0628\u0627\u0639\u062f \u0627\u0644\u0645\u0639\u062f\u0627\u062a.<\/p>\n<p><strong>\u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/strong> \u064a\u062a\u0645 \u062a\u062d\u062f\u064a\u062f \u062a\u0631\u0643\u064a\u0628\u0627\u062a LSZH \u0628\u0634\u0643\u0644 \u0645\u062a\u0632\u0627\u064a\u062f \u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0648\u062a\u0645\u0643\u064a\u0646 \u0627\u0644\u0625\u062e\u0644\u0627\u0621 \u0627\u0644\u0622\u0645\u0646 \u0644\u0644\u0639\u0627\u0645\u0644\u064a\u0646. \u0648\u063a\u0627\u0644\u0628\u0627\u064b \u0645\u0627 \u062a\u0641\u0631\u0636 \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0628\u062a\u0631\u0648\u0643\u064a\u0645\u0627\u0648\u064a\u0629 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0643\u0627\u0628\u0644\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062d\u0631\u064a\u0642 \u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u064a \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0637\u0648\u0627\u0631\u0626.<\/p>\n<p><strong>\u0645\u062d\u0637\u0627\u062a \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629<\/strong> \u062a\u062a\u0637\u0644\u0628 \u0643\u0627\u0628\u0644\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062d\u0631\u064a\u0642 (IEC 60331) \u0644\u0623\u0646\u0638\u0645\u0629 \u062a\u0639\u062b\u0631 \u0627\u0644\u0645\u0641\u0627\u0639\u0644\u0627\u062a\u060c \u0648\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0645\u064a\u0627\u0647 \u0627\u0644\u062a\u063a\u0630\u064a\u0629 \u0641\u064a \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0637\u0648\u0627\u0631\u0626\u060c \u0648\u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0623\u062e\u0631\u0649 \u0627\u0644\u0645\u062a\u0639\u0644\u0642\u0629 \u0628\u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0646\u0638\u064a\u0645\u064a\u0629 \u0627\u0644\u0646\u0648\u0648\u064a\u0629 \u0623\u0648 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u0643\u0627\u0641\u0626\u0629.<\/p>\n<p><strong>\u0627\u0644\u0645\u0646\u0634\u0622\u062a \u062a\u062d\u062a \u0627\u0644\u0623\u0631\u0636<\/strong> (\u0623\u0646\u0641\u0627\u0642 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0648\u0627\u0644\u0637\u0648\u0627\u0628\u0642 \u0627\u0644\u0633\u0641\u0644\u064a\u0629) \u062a\u062a\u0637\u0644\u0628 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u0644\u0647\u0628 \u0645\u0646 \u0627\u0644\u0641\u0626\u0629 A \u0648\u0627\u0646\u0628\u0639\u0627\u062b\u0627\u062a \u062f\u062e\u0627\u0646 \u0645\u0646\u062e\u0641\u0636\u0629 \u0628\u0633\u0628\u0628 \u0627\u0644\u0645\u0633\u0627\u062d\u0627\u062a \u0627\u0644\u0636\u064a\u0642\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices.webp\" alt=\"\u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u0643\u062a\u0644\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0648\u0636\u062d \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0635\u062d\u064a\u062d \u0644\u0644\u0643\u062a\u0644\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0645\u062c\u062f\u0648\u0644\u0629 \u0627\u0644\u0639\u0627\u0631\u064a\u0629\u060c \u0645\u0639 \u0645\u0642\u0627\u0631\u0646\u0629 \u063a\u062f\u0629 EMC \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062d\u0645\u064a\u0629\" class=\"wp-image-3678\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0638\u0631\u0648\u0641 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0635\u062d\u064a\u062d\u0629 \u0648\u063a\u064a\u0631 \u0627\u0644\u0635\u062d\u064a\u062d\u0629 \u0641\u064a \u0627\u0644\u0643\u062a\u0644 \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0644\u0644\u0648\u062d\u0629 MV\u060c \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0645\u0642\u0627\u0631\u0646\u0629 \u063a\u062f\u0629 EMC \u0644\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u062d\u0645\u064a\u0629.<\/figcaption><\/figure>\n<h2>\u0623\u0641\u0636\u0644 \u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0627\u0644\u062a\u0648\u062c\u064a\u0647 \u062f\u0627\u062e\u0644 \u0644\u0648\u062d\u0627\u062a MV<\/h2>\n<h3>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0641\u0635\u0644<\/h3>\n<p>\u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0633\u0644\u064a\u0645 \u0644\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u064a\u0645\u0646\u0639 \u0627\u0642\u062a\u0631\u0627\u0646 \u0627\u0644\u062a\u062f\u0627\u062e\u0644\u0627\u062a \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u062d\u0648\u0627\u062c\u0632 \u0627\u0644\u062d\u0631\u064a\u0642 \u0628\u064a\u0646 \u0641\u0626\u0627\u062a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a:<\/p>\n<p><strong>\u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062c\u0633\u062f\u064a<\/strong> \u0628\u064a\u0646 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u062a\u0628\u0627\u0639 \u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u0640 300 \u0645\u0645 - \u0645\u0639 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0633\u0627\u0641\u0629 300 \u0645\u0645 \u0643\u062d\u062f \u0623\u062f\u0646\u0649 \u0623\u0648 \u062a\u0631\u0643\u064a\u0628 \u062d\u0648\u0627\u062c\u0632 \u0645\u0639\u062f\u0646\u064a\u0629 \u0639\u0646\u062f\u0645\u0627 \u064a\u0635\u0628\u062d \u0645\u0646 \u0627\u0644\u0636\u0631\u0648\u0631\u064a \u0648\u062c\u0648\u062f \u0645\u0633\u0627\u0641\u0627\u062a \u0623\u0642\u0631\u0628. \u062a\u0632\u062f\u0627\u062f \u0647\u0630\u0647 \u0627\u0644\u0645\u0633\u0627\u0641\u0629 \u0628\u0627\u0644\u062a\u0646\u0627\u0633\u0628 \u0645\u0639 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0641\u0648\u0642 15 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a.<\/p>\n<p><strong>\u0632\u0648\u0627\u064a\u0627 \u0627\u0644\u0639\u0628\u0648\u0631<\/strong> \u0628\u0632\u0627\u0648\u064a\u0629 90 \u062f\u0631\u062c\u0629 \u0644\u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u0627\u0642\u062a\u0631\u0627\u0646 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0639\u0646\u062f\u0645\u0627 \u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0642\u0627\u0637\u0639 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u0639 \u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629. \u062a\u064f\u0646\u0634\u0626 \u0627\u0644\u062a\u0642\u0627\u0637\u0639\u0627\u062a \u0627\u0644\u0645\u0627\u0626\u0644\u0629 \u0645\u0646\u0627\u0637\u0642 \u0627\u0642\u062a\u0631\u0627\u0646 \u0645\u0645\u062f\u0648\u062f\u0629 \u062a\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0633\u062a\u062d\u062b\u0629 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631.<\/p>\n<p><strong>\u0627\u0644\u062a\u0648\u062c\u064a\u0647 \u0627\u0644\u0631\u0623\u0633\u064a<\/strong> \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0642\u0635\u0648\u0631\u0627\u062a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0645\u0627\u0646\u0639 \u0627\u0644\u062d\u0631\u064a\u0642 \u0639\u0646\u062f \u0627\u062e\u062a\u0631\u0627\u0642\u0627\u062a \u0627\u0644\u0623\u0631\u0636\u064a\u0629 \u0648\u0627\u0644\u0633\u0642\u0641. \u062a\u0639\u0645\u0644 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0646\u0642\u0644 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0645\u0633\u0628\u0642\u064b\u0627 \u0648\u0627\u0644\u0645\u0632\u0648\u062f\u0629 \u0628\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0645\u062e\u062a\u0628\u0631\u0629 \u0644\u0644\u062d\u0631\u064a\u0642 \u0639\u0644\u0649 \u062a\u0628\u0633\u064a\u0637 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644.<\/p>\n<p>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u0633\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0637\u0648\u0644 \u062e\u0627\u0631\u062c \u0646\u0637\u0627\u0642 \u0645\u062c\u0645\u0648\u0639\u0629 \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629\u060c \u064a\u062c\u0628 \u062a\u0648\u0633\u064a\u0639 \u0646\u0637\u0627\u0642 \u062e\u0637\u0629 \u0627\u0644\u0641\u0635\u0644 \u0646\u0641\u0633\u0647\u0627 \u0644\u062a\u0634\u0645\u0644 \u0646\u0638\u0627\u0645 \u062f\u0639\u0645 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0641\u064a \u0627\u0644\u0645\u0635\u0646\u0639\u061b \u0623 <a href=\"https:\/\/xmqj.com\/\" target=\"_blank\" rel=\"noopener\">\u062f\u0644\u064a\u0644 \u062a\u0631\u0643\u064a\u0628 \u062d\u0627\u0645\u0644 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a<\/a> \u064a\u0633\u0627\u0639\u062f \u0639\u0644\u0649 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u062a\u0633\u0627\u0642 \u0645\u0633\u062a\u0648\u0649 \u0645\u0644\u0621 \u0627\u0644\u0635\u064a\u0646\u064a\u0629\u060c \u0648\u0627\u0644\u0645\u0633\u0627\u0641\u0627\u062a \u0628\u064a\u0646\u0647\u0627\u060c \u0648\u0646\u0642\u0627\u0637 \u0645\u0646\u0639 \u0627\u0646\u062a\u0642\u0627\u0644 \u0627\u0644\u062d\u0631\u064a\u0642\u060c \u0648\u0646\u0635\u0641 \u0642\u0637\u0631 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621 \u0628\u0639\u062f \u062e\u0631\u0648\u062c \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u0646 \u0644\u0648\u062d\u0629 MV.<\/p>\n<h3>\u0627\u0639\u062a\u0628\u0627\u0631\u0627\u062a \u0646\u0635\u0641 \u0642\u0637\u0631 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621<\/h3>\n<p>\u062a\u0648\u0627\u0632\u0646 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0623\u0646\u0635\u0627\u0641 \u0623\u0642\u0637\u0627\u0631 \u062b\u0646\u064a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u064a\u0646 \u0642\u064a\u0648\u062f \u0627\u0644\u0625\u062c\u0647\u0627\u062f \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0648\u0642\u064a\u0648\u062f \u0627\u0644\u062a\u0631\u0643\u064a\u0628:<\/p>\n<ul>\n<li><strong>\u0643\u0627\u0628\u0644\u0627\u062a \u063a\u064a\u0631 \u0645\u0635\u0641\u062d\u0629<\/strong>: 6 \u0623\u0636\u0639\u0627\u0641 \u0627\u0644\u0642\u0637\u0631 \u0627\u0644\u0643\u0644\u064a \u0644\u0644\u0643\u0627\u0628\u0644 6 \u0645\u0631\u0627\u062a \u0643\u062d\u062f \u0623\u062f\u0646\u0649<\/li>\n<li><strong>\u0643\u0627\u0628\u0644\u0627\u062a \u0645\u0635\u0641\u062d\u0629<\/strong>: \u0627\u0644\u0642\u0637\u0631 \u0627\u0644\u0643\u0644\u064a 12 \u0645\u0631\u0629 \u0643\u062d\u062f \u0623\u062f\u0646\u0649<\/li>\n<li><strong>\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0627\u0644\u0647\u062c\u064a\u0646\u0629<\/strong>: \u062d\u0633\u0628 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629\u060c \u0639\u0627\u062f\u0629 \u0645\u0627 \u064a\u0643\u0648\u0646 \u0627\u0644\u0642\u0637\u0631 15-20 \u0645\u0631\u0629<\/li>\n<\/ul>\n<p>\u064a\u0624\u062f\u064a \u062a\u062c\u0627\u0648\u0632 \u062d\u062f\u0648\u062f \u0646\u0635\u0641 \u0642\u0637\u0631 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0625\u0644\u0649 \u062d\u062f\u0648\u062b \u062a\u0644\u0641 \u0641\u0648\u0631\u064a \u0623\u0648 \u0643\u0627\u0645\u0646 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0627\u0633\u062a\u0637\u0627\u0644\u0629 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0648\u062a\u0634\u0648\u0647 \u0627\u0644\u062f\u0631\u0639 \u0648\u062a\u0634\u0642\u0642 \u0627\u0644\u0639\u0632\u0644. \u0644\u0642\u062f \u062a\u062a\u0628\u0639\u062a \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u062a\u062d\u0642\u064a\u0642\u0627\u062a \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u062a\u0642\u0637\u0639\u0629 \u0625\u0644\u0649 \u062a\u0644\u0641 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0639\u0646\u062f \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621\u0627\u062a \u0627\u0644\u062d\u0627\u062f\u0629\u060c \u062e\u0627\u0635\u0629\u064b \u062f\u0627\u062e\u0644 \u062d\u0627\u0648\u064a\u0627\u062a \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u0627\u0644\u0645\u062d\u0635\u0648\u0631\u0629.<\/p>\n<h3>\u062f\u0639\u0645 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0648\u062d\u0645\u0627\u064a\u062a\u0647\u0627<\/h3>\n<p>\u062f\u0627\u062e\u0644 \u0627\u0644\u0644\u0648\u062d\u0627\u062a MV\u060c \u064a\u062c\u0628 \u0623\u0646 \u062a\u0633\u062a\u0648\u0639\u0628 \u0622\u0644\u064a\u0627\u062a \u062f\u0639\u0645 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u062f\u0627\u062e\u0644 \u0627\u0644\u0644\u0648\u062d\u0627\u062a MV \u0627\u0644\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a \u0648\u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0627\u0644\u0635\u064a\u0627\u0646\u0629:<\/p>\n<p><strong>\u0635\u0648\u0627\u0646\u064a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a<\/strong> \u0628\u0646\u0633\u0628 \u062a\u0639\u0628\u0626\u0629 \u0645\u0646\u0627\u0633\u0628\u0629 (40% \u0643\u062d\u062f \u0623\u0642\u0635\u0649 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u064850% \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645) \u062a\u062a\u064a\u062d \u062a\u0628\u062f\u064a\u062f \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0643\u0627\u0641\u064a \u0648\u0625\u0636\u0627\u0641\u0627\u062a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644\u064a\u0629. \u062a\u0633\u0647\u0644 \u0627\u0644\u0635\u0648\u0627\u0646\u064a \u0645\u0646 \u0646\u0648\u0639 \u0627\u0644\u0633\u0644\u0645 \u0625\u0633\u0642\u0627\u0637 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0631\u0623\u0633\u064a\u0629 \u0628\u0634\u0643\u0644 \u0623\u0641\u0636\u0644 \u0645\u0646 \u0627\u0644\u0628\u062f\u0627\u0626\u0644 \u0630\u0627\u062a \u0627\u0644\u0642\u0627\u0639 \u0627\u0644\u0635\u0644\u0628.<\/p>\n<p><strong>\u0645\u0631\u0627\u0628\u0637 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a<\/strong> \u0639\u0644\u0649 \u0645\u0633\u0627\u0641\u0627\u062a \u0645\u0646\u0627\u0633\u0628\u0629 \u0644\u0645\u0646\u0639 \u062d\u0631\u0643\u0629 \u0627\u0644\u0643\u0627\u0628\u0644 \u0623\u062b\u0646\u0627\u0621 \u0623\u062d\u062f\u0627\u062b \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629. \u064a\u062c\u0628 \u0623\u0646 \u062a\u0623\u062e\u0630 \u062d\u0633\u0627\u0628\u0627\u062a \u062a\u0628\u0627\u0639\u062f \u0627\u0644\u0645\u0631\u0627\u0628\u0637 \u0641\u064a \u0627\u0644\u062d\u0633\u0628\u0627\u0646 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u062d\u062a\u0645\u0644\u0629 \u0639\u0644\u0649 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628.<\/p>\n<p><strong>\u0627\u0646\u062a\u0642\u0627\u0644\u0627\u062a \u0627\u0644\u0642\u0646\u0627\u0629 \u0627\u0644\u0645\u0631\u0646\u0629<\/strong> \u0639\u0646\u062f \u0646\u0642\u0627\u0637 \u062f\u062e\u0648\u0644 \u0627\u0644\u0644\u0648\u062d\u0629 \u062a\u0633\u062a\u0648\u0639\u0628 \u062a\u0641\u0627\u0648\u062a\u0627\u062a \u0627\u0644\u0623\u0628\u0639\u0627\u062f \u0648\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0646\u0642\u0644 \u0627\u0644\u0637\u0641\u064a\u0641\u0629 \u0644\u0644\u0648\u062d\u0629. \u062a\u0648\u0641\u0631 \u0627\u0644\u0623\u0646\u0628\u0648\u0628 \u0627\u0644\u0645\u0639\u062f\u0646\u064a \u0627\u0644\u0645\u0631\u0646 \u0627\u0644\u0645\u062d\u0643\u0645 \u0627\u0644\u0633\u0648\u0627\u0626\u0644 \u062d\u0645\u0627\u064a\u0629 \u0628\u064a\u0626\u064a\u0629 \u0645\u0639 \u0627\u0644\u0633\u0645\u0627\u062d \u0628\u0625\u0639\u0627\u062f\u0629 \u062a\u0648\u062c\u064a\u0647 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0639\u062f\u064a\u0644\u0627\u062a.<\/p>\n<hr \/>\n<h2>\u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0645\u0646 \u0623\u062c\u0644 \u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0645\u0648\u062b\u0648\u0642\u0629<\/h2>\n<h3>\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u062a\u0644\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629<\/h3>\n<p>\u064a\u0624\u062b\u0631 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u062a\u0644\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0639\u0644\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0639\u0644\u0649 \u0627\u0644\u0645\u062f\u0649 \u0627\u0644\u0637\u0648\u064a\u0644:<\/p>\n<p><strong>\u0623\u0637\u0631\u0627\u0641 \u0637\u0631\u0641\u0627\u0646 \u0645\u062d\u0645\u0644\u0627\u0646 \u0628\u0646\u0627\u0628\u0636<\/strong> \u062a\u0648\u0641\u0631 \u0636\u063a\u0637 \u062a\u0644\u0627\u0645\u0633 \u062b\u0627\u0628\u062a \u0628\u063a\u0636 \u0627\u0644\u0646\u0638\u0631 \u0639\u0646 \u062a\u062f\u0648\u064a\u0631 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0627\u0647\u062a\u0632\u0627\u0632. \u0648\u064a\u0624\u062f\u064a \u0627\u0644\u062a\u062e\u0644\u0635 \u0645\u0646 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062f\u0648\u0631\u064a\u0629 \u0644\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0636\u0628\u0637 \u0625\u0644\u0649 \u0632\u064a\u0627\u062f\u0629 \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u064a\u0629 \u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629.<\/p>\n<p><strong>\u0623\u0637\u0631\u0627\u0641 \u0637\u0631\u0641\u0627\u0646 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0644\u0648\u0644\u0628\u064a<\/strong> \u062a\u0638\u0644 \u0642\u064a\u0627\u0633\u064a\u0629 \u0644\u0623\u062d\u062c\u0627\u0645 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0648\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u062d\u0642\u0642 \u0627\u0644\u0628\u0635\u0631\u064a \u0645\u0646 \u0639\u0632\u0645 \u0627\u0644\u062f\u0648\u0631\u0627\u0646. \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0633\u0644\u064a\u0645 \u0623\u062f\u0648\u0627\u062a \u0645\u0639\u0627\u064a\u0631\u0629 \u0644\u0639\u0632\u0645 \u0627\u0644\u062f\u0648\u0631\u0627\u0646 \u0648\u0639\u0644\u0627\u0645\u0627\u062a \u0645\u0646\u0627\u0633\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0637\u0631\u0641\u064a\u0629.<\/p>\n<p><strong>\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0625\u0632\u0627\u062d\u0629 \u0627\u0644\u0639\u0627\u0632\u0644\u0629 (IDC)<\/strong> \u062a\u062a\u064a\u062d \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0633\u0631\u064a\u0639 \u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0630\u0627\u062a \u0627\u0644\u0645\u0642\u0627\u064a\u064a\u0633 \u0627\u0644\u0635\u063a\u064a\u0631\u0629 \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062a\u0637\u0644\u0628 \u0645\u0637\u0627\u0628\u0642\u0629 \u062f\u0642\u064a\u0642\u0629 \u0644\u0645\u0642\u0627\u064a\u064a\u0633 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a. \u062a\u0646\u0627\u0633\u0628 \u0623\u0637\u0631\u0627\u0641 \u062a\u0648\u0635\u064a\u0644 IDC \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0648\u0627\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u062d\u064a\u062b \u062a\u0628\u0631\u0631 \u0633\u0631\u0639\u0629 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0642\u064a\u0648\u062f \u0627\u0644\u0645\u0642\u064a\u0627\u0633.<\/p>\n<h3>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0628\u0627\u0644\u062a\u062c\u0639\u064a\u062f<\/h3>\n<p>\u062a\u0648\u0641\u0631 \u0627\u0644\u0646\u0647\u0627\u064a\u0627\u062a \u0627\u0644\u0645\u062c\u0639\u062f\u0629 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0641\u0627\u0626\u0642\u0629 \u0645\u0642\u0627\u0631\u0646\u0629\u064b \u0628\u0627\u0644\u0637\u0631\u0641 \u0627\u0644\u0644\u0648\u0644\u0628\u064a\u0629 \u0639\u0646\u062f \u062a\u0646\u0641\u064a\u0630\u0647\u0627 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d:<\/p>\n<p><strong>\u0645\u0639\u0627\u064a\u0631\u0629 \u0623\u062f\u0627\u0629 \u0627\u0644\u062a\u062c\u0639\u064a\u062f<\/strong> \u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0645 \u0627\u0644\u062a\u062d\u0642\u0642 \u0643\u0644 \u062b\u0644\u0627\u062b\u0629 \u0623\u0634\u0647\u0631 \u0623\u0648 \u062d\u0633\u0628 \u062a\u0648\u0635\u064a\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629. \u064a\u0646\u062a\u062c \u0639\u0646 \u0627\u0644\u0642\u0648\u0627\u0644\u0628 \u0627\u0644\u0628\u0627\u0644\u064a\u0629 \u062a\u062c\u0639\u064a\u062f\u0627\u062a \u0631\u062e\u0648\u0629 \u0642\u062f \u062a\u062c\u062a\u0627\u0632 \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0628\u0635\u0631\u064a \u0628\u064a\u0646\u0645\u0627 \u062a\u0648\u0641\u0631 \u0636\u063a\u0637 \u062a\u0644\u0627\u0645\u0633 \u063a\u064a\u0631 \u0643\u0627\u0641\u064d.<\/p>\n<p><strong>\u0625\u0639\u062f\u0627\u062f \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a<\/strong> \u064a\u062a\u0636\u0645\u0646 \u0637\u0648\u0644 \u0627\u0644\u0634\u0631\u064a\u0637 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 (\u062a\u062c\u0646\u0628 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u0643\u0634\u0648\u0641\u0629 \u062e\u0627\u0631\u062c \u0627\u0644\u0628\u0631\u0645\u064a\u0644)\u060c \u0648\u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u062e\u064a\u0648\u0637 (\u0639\u062f\u0645 \u0648\u062c\u0648\u062f \u062e\u064a\u0648\u0637 \u0645\u0642\u0637\u0648\u0639\u0629 \u0623\u0648 \u0645\u062a\u0642\u0627\u0637\u0639\u0629)\u060c \u0648\u0627\u0644\u0646\u0638\u0627\u0641\u0629 (\u0625\u0632\u0627\u0644\u0629 \u0637\u0628\u0642\u0627\u062a \u0627\u0644\u0623\u0643\u0633\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0642\u062f\u064a\u0645\u0629).<\/p>\n<p><strong>\u0645\u0639\u0627\u064a\u064a\u0631 \u0641\u062d\u0635 \u0627\u0644\u062a\u062c\u0639\u064a\u062f<\/strong> \u062a\u0634\u0645\u0644 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0633\u0644\u064a\u0645 \u0644\u0644\u0642\u0627\u0644\u0628 \u0648\u0645\u0648\u0636\u0639 \u0627\u0644\u0645\u0648\u0635\u0644 \u0641\u064a \u0627\u0644\u0645\u0646\u062a\u0635\u0641 \u0648\u0628\u0631\u0648\u0632 \u0627\u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u0645\u0631\u0626\u064a \u0641\u064a \u0637\u0631\u0641 \u0627\u0644\u0645\u0627\u0633\u0648\u0631\u0629. \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0641\u062d\u0635 100% \u0644\u0644\u062a\u062c\u0639\u064a\u062f \u0641\u064a \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629.<\/p>\n<h3>\u0637\u0631\u0642 \u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062f\u0631\u0639<\/h3>\n<p>\u062a\u0624\u062b\u0631 \u062c\u0648\u062f\u0629 \u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062f\u0631\u0639 \u0628\u0634\u0643\u0644 \u0645\u0628\u0627\u0634\u0631 \u0639\u0644\u0649 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u0639:<\/p>\n<p><strong>\u0625\u0646\u0647\u0627\u0621 \u0628\u0632\u0627\u0648\u064a\u0629 360 \u062f\u0631\u062c\u0629<\/strong> \u0645\u0646 \u062e\u0644\u0627\u0644 \u063a\u062f\u062f \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a EMC \u062a\u0648\u0641\u0631 \u062a\u0644\u0627\u0645\u0633 \u062f\u0631\u0639 \u0645\u062d\u064a\u0637\u064a \u0643\u0627\u0645\u0644\u060c \u0645\u0645\u0627 \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062f\u0631\u0639 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0646\u0642\u0637\u0629 \u062f\u062e\u0648\u0644 \u0627\u0644\u0644\u0648\u062d\u0629. \u062a\u0648\u0641\u0631 \u0647\u0630\u0647 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0631\u0641\u0636\u064b\u0627 \u0644\u0644\u0636\u0648\u0636\u0627\u0621 \u0623\u0643\u0628\u0631 \u0628\u0645\u0642\u062f\u0627\u0631 40-60 \u062f\u064a\u0633\u064a\u0628\u0644 \u0645\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0636\u0641\u064a\u0631\u0629 \u0639\u0646\u062f \u0627\u0644\u062a\u0631\u062f\u062f\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0632\u064a\u062f \u0639\u0646 10 \u0645\u064a\u062c\u0627\u0647\u0631\u062a\u0632.<\/p>\n<p><strong>\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0636\u0641\u064a\u0631\u0629<\/strong> (\u0633\u0644\u0643 \u062a\u0635\u0631\u064a\u0641 \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u0645\u0646\u062a\u0647\u064a \u0625\u0644\u0649 \u0646\u0627\u0642\u0644 \u0623\u0631\u0636\u064a) \u062a\u0648\u0641\u0631 \u0627\u0644\u0628\u0633\u0627\u0637\u0629 \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062e\u0644\u0642 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0633\u062a\u0642\u0631\u0627\u0626\u064a\u0629 \u062a\u0642\u0644\u0644 \u0645\u0646 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0639\u0627\u0644\u064a \u0627\u0644\u062a\u0631\u062f\u062f. \u0639\u0646\u062f\u0645\u0627 \u0644\u0627 \u064a\u0645\u0643\u0646 \u062a\u062c\u0646\u0628 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0645\u0635\u0646\u0648\u0639\u0629 \u0645\u0646 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0636\u0641\u064a\u0631\u0629\u060c \u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0623\u0637\u0648\u0627\u0644 \u0623\u0642\u0644 \u0645\u0646 50 \u0645\u0645 \u0648\u0648\u062c\u0647\u0647\u0627 \u0645\u0628\u0627\u0634\u0631\u0629 \u0625\u0644\u0649 \u0623\u0642\u0631\u0628 \u0646\u0642\u0637\u0629 \u0623\u0631\u0636\u064a\u0629.<\/p>\n<p><strong>\u0623\u0646\u0638\u0645\u0629 \u062d\u0627\u0641\u0644\u0627\u062a \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u0648\u0627\u0642\u064a\u0629<\/strong> \u062f\u0645\u062c \u0625\u0646\u0647\u0627\u0621\u0627\u062a \u0627\u0644\u062f\u0631\u0648\u0639 \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \u0641\u064a \u0633\u0637\u062d \u0645\u062a\u0633\u0627\u0648\u064a \u0627\u0644\u062c\u0647\u062f \u0645\u0634\u062a\u0631\u0643\u060c \u0645\u0645\u0627 \u064a\u0633\u0647\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0645\u0639 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u062c\u0648\u062f\u0629 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629. \u062a\u0642\u062f\u0645 \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0623\u0646\u0638\u0645\u0629 \u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0627\u0644\u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0644\u0648\u062d\u0629 \u0627\u0644\u062a\u062d\u0643\u0645.<\/p>\n<hr \/>\n<h2>\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u062a\u062d\u0642\u0642<\/h2>\n<h3>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0627 \u0642\u0628\u0644 \u0627\u0644\u062a\u062b\u0628\u064a\u062a<\/h3>\n<p>\u0642\u0628\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u060c \u064a\u062c\u0628 \u0623\u0646 \u062a\u062e\u0636\u0639 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645:<\/p>\n<p><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644<\/strong> \u0639\u0646\u062f 500 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 \u0643\u062d\u062f \u0623\u062f\u0646\u0649\u060c \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0642\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u062c\u0627\u0648\u0632 100 \u0645\u062a\u0631 \u0645\u0643\u0639\u0628 \u0644\u0643\u0644 \u0643\u064a\u0644\u0648\u0645\u062a\u0631. \u062a\u0634\u064a\u0631 \u0627\u0644\u0642\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0623\u0642\u0644 \u0625\u0644\u0649 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0623\u0648 \u0639\u064a\u0648\u0628 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u0631\u0641\u0636 \u0627\u0644\u0643\u0627\u0628\u0644.<\/p>\n<p><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629<\/strong> \u064a\u0624\u0643\u062f \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0648\u064a\u062d\u062f\u062f \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0645\u062a\u0642\u0627\u0637\u0639\u0629 \u0642\u0628\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0645\u0645\u0627 \u064a\u062c\u0639\u0644 \u0627\u0644\u062a\u0635\u062d\u064a\u062d\u0627\u062a \u0635\u0639\u0628\u0629.<\/p>\n<p><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u062f\u0631\u0639<\/strong> \u0639\u0646\u062f \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u062a\u064a\u0627\u0631 \u0645\u0646\u062e\u0641\u0636\u0629 \u062a\u062d\u062f\u062f \u0627\u0646\u0643\u0633\u0627\u0631\u0627\u062a \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u062a\u064a \u0645\u0646 \u0634\u0623\u0646\u0647\u0627 \u0623\u0646 \u062a\u0624\u062b\u0631 \u0639\u0644\u0649 \u0623\u062f\u0627\u0621 EMC.<\/p>\n<h3>\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0643\u0644\u064a\u0641 \u0628\u0639\u062f \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/h3>\n<p>\u0628\u0639\u062f \u0627\u0643\u062a\u0645\u0627\u0644 \u0627\u0644\u0625\u0646\u0647\u0627\u0621:<\/p>\n<p><strong>\u0625\u0639\u0627\u062f\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644<\/strong> \u064a\u062d\u062f\u062f \u0623\u0636\u0631\u0627\u0631 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0634\u062f \u0627\u0644\u0634\u062f \u0623\u0648 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621\u0627\u062a \u0627\u0644\u062d\u0627\u062f\u0629 \u0623\u0648 \u0627\u0644\u0635\u062f\u0645\u0627\u062a \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0623\u062b\u0646\u0627\u0621 \u0623\u0646\u0634\u0637\u0629 \u0627\u0644\u0625\u0646\u0634\u0627\u0621 \u0627\u0644\u0645\u062a\u0632\u0627\u0645\u0646\u0629.<\/p>\n<p><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0646\u0642\u0637\u0629 \u0625\u0644\u0649 \u0646\u0642\u0637\u0629<\/strong> \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u0635\u062d\u064a\u062d \u0645\u0642\u0627\u0628\u0644 \u0645\u062e\u0637\u0637\u0627\u062a \u0627\u0644\u0623\u0633\u0644\u0627\u0643\u060c \u0648\u0647\u0648 \u0623\u0645\u0631 \u0636\u0631\u0648\u0631\u064a \u0642\u0628\u0644 \u062a\u0646\u0634\u064a\u0637 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645.<\/p>\n<p><strong>\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0633\u062a\u062d\u062b<\/strong> \u0641\u064a \u0638\u0644 \u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u062a\u062d\u062f\u064a\u062f \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0641\u064a \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062d\u0633\u0627\u0633\u0629. \u0625\u0646 \u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u062c\u0627\u0648\u0632 1% \u0645\u0646 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0627\u0644\u0627\u0633\u0645\u064a\u0629 \u062a\u0633\u062a\u062f\u0639\u064a \u0625\u062c\u0631\u0627\u0621 \u062a\u062d\u0642\u064a\u0642 \u0648\u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u062a\u0648\u062c\u064a\u0647.<\/p>\n<p><strong>\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062f\u0631\u0639<\/strong> \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062d\u0642\u0646 \u064a\u0624\u0643\u062f \u0623\u062f\u0627\u0621 \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0641\u064a \u0627\u0644\u062a\u0643\u0648\u064a\u0646\u0627\u062a \u0627\u0644\u0645\u062b\u0628\u062a\u0629.<\/p>\n<hr \/>\n<h2>\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0639\u0645\u0644\u064a\u0629 \u0645\u064a\u062f\u0627\u0646\u064a\u0629 \u0648\u062f\u0631\u0627\u0633\u0627\u062a \u062d\u0627\u0644\u0629 \u0639\u0645\u0644\u064a\u0629<\/h2>\n<h3>\u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a \u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0628\u062a\u0631\u0648\u0643\u064a\u0645\u0627\u0648\u064a\u0627\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629<\/h3>\n<p>\u0623\u062b\u0646\u0627\u0621 \u062a\u0631\u0642\u064a\u0629 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u0624\u062e\u0631\u064b\u0627 \u0641\u064a \u0645\u0635\u0641\u0627\u0629 \u0628\u0633\u0627\u062d\u0644 \u0627\u0644\u062e\u0644\u064a\u062c\u060c \u0623\u0638\u0647\u0631\u062a \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062d\u0627\u0644\u064a\u0629 \u0628\u062c\u0647\u062f 13.8 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0645\u0634\u0627\u0643\u0644 \u062a\u062f\u0627\u062e\u0644 \u0645\u0632\u0645\u0646\u0629. \u0648\u062a\u0639\u0631\u0636\u062a \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0627\u0644\u0645\u0648\u062c\u0647\u0629 \u0628\u062c\u0648\u0627\u0631 \u0643\u0627\u0628\u0644\u0627\u062a \u0637\u0627\u0642\u0629 \u0645\u062d\u0631\u0643 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u062a\u063a\u064a\u0631 \u0644\u0636\u0648\u0636\u0627\u0621 \u0645\u0633\u062a\u062d\u062b\u0629 \u062a\u062a\u062c\u0627\u0648\u0632 \u0642\u062f\u0631\u0627\u062a \u062a\u0631\u0634\u064a\u062d \u0645\u0631\u062d\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629\u060c \u0645\u0645\u0627 \u062a\u0633\u0628\u0628 \u0641\u064a \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u0645\u0632\u0639\u062c\u0629 \u0623\u062b\u0646\u0627\u0621 \u0628\u062f\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643.<\/p>\n<p>\u0648\u0642\u062f \u062a\u0636\u0645\u0646 \u0627\u0644\u062d\u0644 \u062a\u0631\u0643\u064a\u0628 \u062b\u0644\u0627\u062b\u064a\u0627\u062a \u0645\u062d\u0645\u064a\u0629 \u0628\u0634\u0643\u0644 \u0641\u0631\u062f\u064a \u0645\u0639 \u062a\u062f\u0631\u064a\u0639 \u0645\u0631\u0643\u0628 \u0645\u0646 \u0631\u0642\u0627\u0626\u0642\/\u0636\u0641\u064a\u0631\u0629 \u0644\u062c\u0645\u064a\u0639 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628\u060c \u0648\u062a\u0646\u0641\u064a\u0630 \u0648\u0635\u0644\u0627\u062a \u062f\u0631\u0639 \u0628\u0632\u0627\u0648\u064a\u0629 360 \u062f\u0631\u062c\u0629 \u0641\u064a \u0643\u0644\u0627 \u0627\u0644\u0637\u0631\u0641\u064a\u0646\u060c \u0648\u0625\u0639\u0627\u062f\u0629 \u062a\u0648\u062c\u064a\u0647 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0644\u062a\u062d\u0642\u064a\u0642 \u0641\u0635\u0644 450 \u0645\u0645 \u0643\u062d\u062f \u0623\u062f\u0646\u0649 \u0639\u0646 \u0645\u0648\u0635\u0644\u0627\u062a \u0637\u0627\u0642\u0629 \u0645\u062d\u0631\u0643 \u0627\u0644\u062a\u0631\u062f\u062f\u0627\u062a \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629. \u0623\u0643\u062f\u062a \u0642\u064a\u0627\u0633\u0627\u062a \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0636\u0648\u0636\u0627\u0621 \u0627\u0644\u0645\u0633\u062a\u062d\u062b\u0629 \u0645\u0646 \u0630\u0631\u0648\u0629 850 \u0645\u0644\u0644\u064a \u0641\u0648\u0644\u062a \u0625\u0644\u0649 \u0623\u0642\u0644 \u0645\u0646 15 \u0645\u0644\u0644\u064a \u0641\u0648\u0644\u062a - \u0641\u064a \u062d\u062f\u0648\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u0631\u062d\u064a\u0644.<\/p>\n<h3>\u0627\u0644\u0625\u0646\u0634\u0627\u0621\u0627\u062a \u0627\u0644\u062c\u062f\u064a\u062f\u0629 \u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0641\u0631\u0639\u064a\u0629<\/h3>\n<p>\u062d\u062f\u062f \u0645\u0634\u0631\u0648\u0639 \u0645\u062d\u0637\u0629 \u0646\u0642\u0644 \u0641\u0631\u0639\u064a\u0629 \u0628\u062c\u0647\u062f 230\/34.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0643\u0627\u0628\u0644\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062d\u0631\u064a\u0642 \u0644\u062c\u0645\u064a\u0639 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0628\u0639\u062f \u0645\u062e\u0627\u0648\u0641 \u0645\u0646 \u062d\u0648\u0627\u062f\u062b \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u0641\u064a \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0625\u0642\u0644\u064a\u0645\u064a\u0629. \u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u0631\u0643\u064a\u0628:<\/p>\n<ul>\n<li>\u0643\u0627\u0628\u0644\u0627\u062a \u0645\u062a\u0648\u0627\u0641\u0642\u0629 \u0645\u0639 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 IEC 60331 \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062a\u0641\u0627\u0636\u0644\u064a\u0629 \u0648\u062a\u0639\u0637\u0644 \u0627\u0644\u0642\u0648\u0627\u0637\u0639 \u0648\u062f\u0648\u0627\u0626\u0631 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0646\u0627\u0642\u0644<\/li>\n<li>\u0643\u0627\u0628\u0644\u0627\u062a IEC 60332-3 \u0645\u0646 \u0627\u0644\u0641\u0626\u0629 A \u0644\u062c\u0645\u064a\u0639 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0627\u0644\u0623\u062e\u0631\u0649<\/li>\n<li>\u0625\u064a\u0642\u0627\u0641 \u0634\u0627\u0645\u0644 \u0644\u0644\u062d\u0631\u064a\u0642 \u0639\u0646\u062f \u062c\u0645\u064a\u0639 \u0627\u0644\u0627\u062e\u062a\u0631\u0627\u0642\u0627\u062a \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0623\u0646\u0638\u0645\u0629 \u0639\u0628\u0648\u0631 \u0645\u062e\u062a\u0628\u0631\u0629 \u0648\u0645\u0639\u062a\u0645\u062f\u0629<\/li>\n<\/ul>\n<p>\u064a\u064f\u0638\u0647\u0631 \u0627\u0644\u0633\u062c\u0644 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a \u0644\u0645\u062f\u0629 18 \u0634\u0647\u0631\u064b\u0627 \u0639\u062f\u0645 \u062d\u062f\u0648\u062b \u0623\u064a \u062e\u0644\u0644 \u0641\u064a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u064a\u0639\u0632\u0649 \u0625\u0644\u0649 \u0645\u0634\u0643\u0644\u0627\u062a \u0641\u064a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0645\u0645\u0627 \u064a\u0624\u0643\u062f \u0635\u062d\u0629 \u0646\u0647\u062c \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0645\u062a\u062d\u0641\u0638.<\/p>\n<hr \/>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629<\/h2>\n<h3>\u0627\u0644\u0633\u0624\u0627\u0644 1: \u0643\u064a\u0641 \u064a\u0645\u0643\u0646\u0646\u064a \u062a\u062d\u062f\u064a\u062f \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062d\u0645\u064a\u0629 \u0636\u0631\u0648\u0631\u064a\u0629 \u0644\u062a\u0631\u0643\u064a\u0628 \u0644\u0648\u062d\u0629 MV \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u064a\u061f<\/h3>\n<p>\u062a\u0635\u0628\u062d \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u062d\u0645\u064a\u0629 \u0636\u0631\u0648\u0631\u064a\u0629 \u0639\u0646\u062f \u062a\u0648\u062c\u064a\u0647 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0646\u0637\u0627\u0642 300 \u0645\u0645 \u0645\u0646 \u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0623\u0648 \u0639\u0646\u062f \u0648\u062c\u0648\u062f \u0625\u0634\u0627\u0631\u0627\u062a \u062a\u0646\u0627\u0638\u0631\u064a\u0629 \u062d\u0633\u0627\u0633\u0629 (\u0623\u0642\u0644 \u0645\u0646 1 \u0641\u0648\u0644\u062a \u0623\u0648 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0645\u064a\u0643\u0631\u0648\u0623\u0645\u0628\u064a\u0631)\u060c \u0623\u0648 \u0639\u0646\u062f\u0645\u0627 \u062a\u062a\u0637\u0644\u0628 \u0628\u0631\u0648\u062a\u0648\u0643\u0648\u0644\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0623\u062f\u0627\u0621\u064b \u0645\u062d\u062f\u062f\u064b\u0627 \u0644\u0644\u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a EMC\u060c \u0623\u0648 \u0639\u0646\u062f\u0645\u0627 \u062a\u062a\u0636\u0645\u0646 \u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u062a\u063a\u064a\u0631 \u0623\u0648 \u0623\u0641\u0631\u0627\u0646 \u0627\u0644\u0642\u0648\u0633 \u0623\u0648 \u063a\u064a\u0631\u0647\u0627 \u0645\u0646 \u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u062a\u062f\u0627\u062e\u0644 \u0627\u0644\u0639\u0627\u0644\u064a\u0629. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062c\u062f\u064a\u062f\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637\u060c \u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u064a\u0643\u0648\u0646 \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u062d\u0645\u064a\u0629 \u0639\u0627\u0644\u0645\u064a\u064b\u0627 \u0623\u0643\u062b\u0631 \u0627\u0642\u062a\u0635\u0627\u062f\u064b\u0627 \u0645\u0646 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0627\u0646\u062a\u0642\u0627\u0626\u064a\u060c \u0645\u0639 \u0627\u0644\u0623\u062e\u0630 \u0641\u064a \u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631 \u062a\u0643\u0627\u0644\u064a\u0641 \u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627 \u0644\u0644\u0645\u0634\u0627\u0643\u0644 \u0627\u0644\u0645\u062a\u0639\u0644\u0642\u0629 \u0628\u0627\u0644\u0636\u0648\u0636\u0627\u0621.<\/p>\n<h3>\u06332: \u0645\u0627 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 \u0643\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 LSZH \u0648\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0628\u0644\u0627\u0633\u062a\u064a\u0643\u064a\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0645\u0646 \u062d\u064a\u062b \u0627\u0644\u0623\u062f\u0627\u0621 \u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0644\u062d\u0631\u0627\u0626\u0642\u061f<\/h3>\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0643\u0627\u0628\u0644\u0627\u062a LSZH (\u0645\u0646\u062e\u0641\u0636\u0629 \u0627\u0644\u062f\u062e\u0627\u0646 \u0627\u0644\u062e\u0627\u0644\u064a\u0629 \u0645\u0646 \u0627\u0644\u0647\u0627\u0644\u0648\u062c\u064a\u0646) \u0639\u0648\u0627\u0632\u0644 \u0648\u063a\u0644\u0627\u0641 \u0645\u0646 \u0627\u0644\u0628\u0648\u0644\u064a \u0623\u0648\u0644\u064a\u0641\u064a\u0646 \u0627\u0644\u0630\u064a \u064a\u0646\u062a\u062c \u0639\u0646\u0647 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0627\u0644\u062f\u062e\u0627\u0646 \u0648\u0644\u0627 \u064a\u0646\u062a\u062c \u0639\u0646\u0647 \u063a\u0627\u0632\u0627\u062a \u062d\u0645\u0636\u064a\u0629 \u0623\u0643\u0627\u0644\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0627\u062d\u062a\u0631\u0627\u0642. \u062a\u0637\u0644\u0642 \u0643\u0627\u0628\u0644\u0627\u062a PVC \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u063a\u0627\u0632 \u0643\u0644\u0648\u0631\u064a\u062f \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u062c\u064a\u0646 \u0639\u0646\u062f \u0627\u0644\u0627\u062d\u062a\u0631\u0627\u0642\u060c \u0648\u0627\u0644\u0630\u064a \u064a\u0634\u0643\u0644 \u062d\u0645\u0636 \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u0643\u0644\u0648\u0631\u064a\u0643 \u0641\u064a \u0648\u062c\u0648\u062f \u0627\u0644\u0631\u0637\u0648\u0628\u0629\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u062a\u0622\u0643\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0642\u0631\u064a\u0628\u0629 \u0648\u064a\u062e\u0644\u0642 \u0645\u062e\u0627\u0637\u0631 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u062a\u0646\u0641\u0633\u064a. \u0628\u064a\u0646\u0645\u0627 \u062a\u0643\u0644\u0641 \u0643\u0627\u0628\u0644\u0627\u062a LSZH \u0639\u0627\u062f\u0629\u064b 15-25% \u0623\u0643\u062b\u0631 \u0645\u0646 \u0645\u062b\u064a\u0644\u0627\u062a\u0647\u0627 \u0645\u0646 PVC\u060c \u0641\u0625\u0646 \u0627\u0646\u062e\u0641\u0627\u0636 \u0623\u0636\u0631\u0627\u0631 \u0627\u0644\u062a\u0622\u0643\u0644 \u0639\u0644\u0649 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0629 \u0648\u062a\u062d\u0633\u064a\u0646 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0625\u062e\u0644\u0627\u0621 \u064a\u0628\u0631\u0631 \u0639\u0644\u0627\u0648\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0641\u064a \u0627\u0644\u0623\u0645\u0627\u0643\u0646 \u0627\u0644\u0645\u063a\u0644\u0642\u0629 \u0648\u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0630\u0627\u062a \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u062d\u0633\u0627\u0633\u0629.<\/p>\n<h3>\u06333: \u0647\u0644 \u064a\u0645\u0643\u0646\u0646\u064a \u062a\u0648\u062c\u064a\u0647 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0641\u064a \u0646\u0641\u0633 \u0642\u0646\u0627\u0629 \u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0631\u0642\u0645\u064a\u0629\u061f<\/h3>\n<p>\u0646\u0639\u0645\u060c \u0645\u0639 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u0627\u062a \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629. \u0627\u0633\u062a\u062e\u062f\u0645 \u0643\u0627\u0628\u0644\u0627\u062a \u0645\u062d\u0645\u064a\u0629 \u0628\u0634\u0643\u0644 \u0641\u0631\u062f\u064a \u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u0644\u0645\u0646\u0639 \u0627\u0642\u062a\u0631\u0627\u0646 \u0627\u0644\u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0628\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u062c\u0627\u0648\u0631\u0629. \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0646\u0633\u0628\u0629 \u0645\u0644\u0621 \u0627\u0644\u0642\u0646\u0627\u0629 \u062a\u0633\u0645\u062d \u0628\u0645\u0633\u0627\u0641\u0627\u062a \u0643\u0627\u0641\u064a\u0629 \u0628\u064a\u0646 \u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a. \u0636\u0639 \u0641\u064a \u0627\u0639\u062a\u0628\u0627\u0631\u0643 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u062a\u064a\u0627\u0631 \u0627\u0644\u0639\u0637\u0644 - \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062d\u0645\u0644 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062b\u0627\u0646\u0648\u064a\u0629 \u0644\u0644\u062a\u0635\u0648\u064a\u0631 \u0627\u0644\u0645\u0642\u0637\u0639\u064a \u0627\u0644\u0645\u062d\u0648\u0633\u0628 \u062a\u064a \u062a\u064a \u062a\u064a \u062a\u064a \u062a\u064a \u062a\u064a\u0627\u0631\u0627\u062a \u0643\u0628\u064a\u0631\u0629 \u0623\u062b\u0646\u0627\u0621 \u0623\u0639\u0637\u0627\u0644 \u0646\u0638\u0627\u0645 \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0648\u064a\u062c\u0628 \u0623\u0646 \u064a\u0623\u062e\u0630 \u062a\u062d\u062f\u064a\u062f \u062d\u062c\u0645 \u0627\u0644\u0645\u0648\u0635\u0644 \u0641\u064a \u0627\u0644\u0627\u0639\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0623\u062b\u064a\u0631\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0631\u062c\u0629\u060c \u064a\u0648\u0641\u0631 \u0627\u0644\u062a\u0648\u062c\u064a\u0647 \u0627\u0644\u0645\u0646\u0641\u0635\u0644 \u0636\u0645\u0627\u0646\u064b\u0627 \u0625\u0636\u0627\u0641\u064a\u064b\u0627 \u0644\u0644\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u064a\u0633\u062a\u062d\u0642 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u0636\u0627\u0641\u064a\u0629 \u0627\u0644\u0645\u062a\u0648\u0627\u0636\u0639\u0629.<\/p>\n<h3>\u06334: \u0645\u0627 \u0647\u064a \u0637\u0631\u064a\u0642\u0629 \u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0623\u0646 \u0623\u0633\u062a\u062e\u062f\u0645\u0647\u0627 \u0641\u064a \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644 IEC 61850 GOOSE\u061f<\/h3>\n<p>\u064a\u0639\u0645\u0644 \u0627\u062a\u0635\u0627\u0644 IEC 61850 GOOSE (\u062d\u062f\u062b \u0627\u0644\u0645\u062d\u0637\u0629 \u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0627\u0644\u0645\u0648\u062c\u0647 \u0644\u0644\u0643\u0627\u0626\u0646\u0627\u062a \u0627\u0644\u0639\u0627\u0645\u0629) \u0628\u0633\u0631\u0639\u0627\u062a \u0625\u064a\u062b\u0631\u0646\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u0645\u0646\u0627\u0639\u0629 \u0636\u062f \u0627\u0644\u0636\u0648\u0636\u0627\u0621 \u0639\u0631\u064a\u0636\u0629 \u0627\u0644\u0646\u0637\u0627\u0642. \u064a\u0648\u0641\u0631 \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0645\u062a\u0639\u062f\u062f \u0627\u0644\u0646\u0642\u0627\u0637 \u0644\u0644\u062f\u0631\u0639 \u0639\u0646\u062f \u0637\u0631\u0641\u064a \u0627\u0644\u0643\u0627\u0628\u0644 \u0648\u0639\u0646\u062f \u0623\u064a \u0646\u0642\u0627\u0637 \u062a\u0642\u0627\u0637\u0639 \u0648\u0633\u064a\u0637\u0629 \u062d\u0645\u0627\u064a\u0629 \u0645\u062b\u0627\u0644\u064a\u0629 \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062f\u062f. \u0627\u0633\u062a\u062e\u062f\u0645 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0645\u062d\u0645\u064a\u0629 \u0648\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u062f\u0631\u0639 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0648\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644. \u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0635\u0644 \u0627\u0644\u062f\u0631\u0639 \u0628\u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0623\u0631\u0636\u064a \u0627\u0644\u0648\u0627\u0642\u064a \u0639\u0646\u062f \u0643\u0644 \u0646\u0642\u0637\u0629 \u0625\u0646\u0647\u0627\u0621\u060c \u0645\u0645\u0627 \u064a\u062e\u0644\u0642 \u0645\u0633\u0627\u0631\u064b\u0627 \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u062d\u062b\u0629.<\/p>\n<h3>\u06335: \u0643\u0645 \u0645\u0631\u0629 \u064a\u062c\u0628 \u0625\u0639\u0627\u062f\u0629 \u0636\u0628\u0637 \u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0623\u0637\u0631\u0627\u0641 \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0635\u064a\u0627\u0646\u0629\u061f<\/h3>\n<p>\u064a\u062c\u0628 \u0625\u0639\u0627\u062f\u0629 \u0636\u0628\u0637 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0644\u0648\u0644\u0628\u064a \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0623\u0648\u0644\u064a (\u0628\u0639\u062f 24-48 \u0633\u0627\u0639\u0629 \u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0644\u0644\u0633\u0645\u0627\u062d \u0628\u0627\u0644\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a)\u060c \u0648\u0641\u064a \u0623\u0648\u0644 \u0641\u062a\u0631\u0629 \u0635\u064a\u0627\u0646\u0629 \u0633\u0646\u0648\u064a\u0629 \u0648\u0628\u0639\u062f \u0630\u0644\u0643 \u0639\u0644\u0649 \u0641\u062a\u0631\u0627\u062a \u062a\u062a\u0631\u0627\u0648\u062d \u0628\u064a\u0646 3 \u06485 \u0633\u0646\u0648\u0627\u062a \u062d\u0633\u0628 \u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644. \u0642\u062f \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0645\u0639\u0631\u0636\u0629 \u0644\u0644\u0627\u0647\u062a\u0632\u0627\u0632\u0627\u062a \u0623\u0648 \u0627\u0644\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0623\u0648 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0630\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0639\u0627\u0644\u064a \u0639\u0646\u0627\u064a\u0629 \u0623\u0643\u062b\u0631 \u062a\u0643\u0631\u0627\u0631\u064b\u0627. \u062a\u0633\u062a\u063a\u0646\u064a \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0627\u0644\u0645\u062d\u0645\u0644\u0629 \u0628\u0646\u0627\u0628\u0636 \u0639\u0646 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0631\u0628\u0637 \u062a\u0645\u0627\u0645\u064b\u0627\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647\u0627 \u0645\u0641\u0636\u0644\u0629 \u0628\u0634\u0643\u0644 \u0645\u062a\u0632\u0627\u064a\u062f \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u064a \u064a\u0643\u0648\u0646 \u0641\u064a\u0647\u0627 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0635\u0639\u0628\u064b\u0627 \u0623\u0648 \u0645\u0643\u0644\u0641\u064b\u0627.<\/p>\n<h3>\u0633 6: \u0645\u0627 \u0647\u064a \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0623\u0646 \u0623\u062d\u062a\u0641\u0638 \u0628\u0647\u0627 \u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0627\u062a MV\u061f<\/h3>\n<p>\u062a\u0634\u062a\u0645\u0644 \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0639\u0644\u0649 \u062c\u062f\u0627\u0648\u0644 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062d\u062f\u062f \u0643\u0644 \u0643\u0627\u0628\u0644 \u0628\u0645\u0639\u0631\u0641\u0627\u062a \u0641\u0631\u064a\u062f\u0629 \u0648\u0623\u0644\u0648\u0627\u0646 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0648\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0648\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a. \u0627\u0644\u0627\u062d\u062a\u0641\u0627\u0638 \u0628\u0631\u0633\u0648\u0645\u0627\u062a \u0627\u0644\u062a\u0648\u062c\u064a\u0647 \u062d\u0633\u0628 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u062a\u064a \u062a\u0648\u0636\u062d \u0645\u0648\u0627\u0636\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 (\u0648\u0644\u064a\u0633 \u0641\u0642\u0637 \u0646\u064a\u0629 \u0627\u0644\u062a\u0635\u0645\u064a\u0645). \u0627\u0644\u0627\u062d\u062a\u0641\u0627\u0638 \u0628\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0642\u064a\u0627\u0633\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0648\u0646\u062a\u0627\u0626\u062c \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0648\u0623\u064a \u0627\u062e\u062a\u0628\u0627\u0631 \u0644\u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062f\u0631\u0639. \u0627\u062d\u062a\u0641\u0638 \u0628\u0623\u0648\u0631\u0627\u0642 \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u062a\u064a \u062a\u0624\u0643\u062f \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u062d\u0631\u064a\u0642 \u0648\u0627\u0644\u062e\u0635\u0627\u0626\u0635 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u062a\u062b\u0628\u062a \u0647\u0630\u0647 \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0623\u0646\u0647\u0627 \u0644\u0627 \u062a\u0642\u062f\u0631 \u0628\u062b\u0645\u0646 \u0623\u062b\u0646\u0627\u0621 \u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627 \u0648\u0627\u0644\u062a\u0639\u062f\u064a\u0644\u0627\u062a \u0648\u0627\u0644\u062a\u062f\u0642\u064a\u0642 \u0627\u0644\u062a\u0646\u0638\u064a\u0645\u064a.<\/p>\n<h3>\u06337: \u0643\u064a\u0641 \u064a\u0645\u0643\u0646\u0646\u064a \u0645\u0646\u0639 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u0646\u0647\u0627\u064a\u0627\u062a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u061f<\/h3>\n<p>\u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0625\u0646\u0647\u0627\u0621\u0627\u062a \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 \u0627\u062e\u062a\u064a\u0627\u0631 \u063a\u062f\u0629 \u0643\u0627\u0628\u0644 \u0645\u0646\u0627\u0633\u0628\u0629 \u0645\u0639 \u062a\u0635\u0646\u064a\u0641\u0627\u062a IP (\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062f\u062e\u0648\u0644) \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629 - \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 IP66 \u0644\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629 MV. \u0636\u0639 \u0645\u0627\u0646\u0639\u0627\u062a \u0627\u0644\u062a\u0633\u0631\u0628 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629 \u0639\u0646\u062f \u0646\u0642\u0627\u0637 \u062f\u062e\u0648\u0644 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0628\u0627\u062a\u0628\u0627\u0639 \u062a\u0639\u0644\u064a\u0645\u0627\u062a \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629. \u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0639\u0628\u0648\u0627\u062a \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0644\u062a\u0635\u0631\u064a\u0641 \u0627\u0644\u0645\u0646\u0627\u0633\u0628 (\u0641\u062a\u062d\u0627\u062a \u0627\u0644\u062a\u0635\u0641\u064a\u0629 \u0639\u0646\u062f \u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629) \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0645\u062d\u0627\u0648\u0644\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u062d\u0643\u0645 \u0627\u0644\u0630\u064a \u064a\u0641\u0634\u0644 \u062d\u062a\u0645\u064b\u0627. \u0636\u0639 \u0641\u064a \u0627\u0639\u062a\u0628\u0627\u0631\u0643 \u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062a\u0646\u0641\u0633 \u0627\u0644\u062a\u064a \u062a\u0639\u0627\u062f\u0644 \u0627\u0644\u0636\u063a\u0637 \u0645\u0639 \u0645\u0646\u0639 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629\u060c \u062d\u062f\u062f \u0643\u062a\u0644 \u0637\u0631\u0641\u064a\u0629 \u0645\u0645\u0644\u0648\u0621\u0629 \u0628\u0627\u0644\u0647\u0644\u0627\u0645 \u062a\u0633\u062a\u0628\u0639\u062f \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0646 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0648\u0635\u064a\u0644.<\/p>\n<hr \/>\n<h2>\u0627\u0644\u062e\u0627\u062a\u0645\u0629: \u0627\u0644\u0648\u062c\u0628\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0644\u062a\u0645\u064a\u0632 \u0641\u064a \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645<\/h2>\n<p>\u064a\u062a\u0637\u0644\u0628 \u0627\u062e\u062a\u064a\u0627\u0631 \u0643\u0627\u0628\u0644 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0627\u0644\u0627\u0647\u062a\u0645\u0627\u0645 \u0628\u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0639\u0648\u0627\u0645\u0644 \u0627\u0644\u0645\u062a\u0631\u0627\u0628\u0637\u0629 \u0627\u0644\u062a\u064a \u062a\u062d\u062f\u062f \u0645\u062c\u062a\u0645\u0639\u0629\u064b \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0646\u0638\u0627\u0645 \u0648\u0633\u0644\u0627\u0645\u062a\u0647. \u064a\u062c\u0628 \u0623\u0646 \u062a\u0648\u062c\u0647 \u0627\u0644\u0645\u0628\u0627\u062f\u0626 \u0627\u0644\u062a\u0627\u0644\u064a\u0629 \u0642\u0631\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0648\u0627\u0644\u062a\u0631\u0643\u064a\u0628:<\/p>\n<p><strong>\u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0637\u0627\u0628\u0642 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0645\u0639 \u0627\u0644\u0628\u064a\u0626\u0629 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629.<\/strong> \u0641\u0647\u0645 \u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u062a\u062f\u0627\u062e\u0644\u060c \u0648\u062a\u0642\u064a\u064a\u0645 \u062d\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u0625\u0634\u0627\u0631\u0629\u060c \u0648\u0627\u062e\u062a\u064a\u0627\u0631 \u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u062f\u0631\u0648\u0639 \u0648\u0637\u0631\u0642 \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629. \u0646\u0627\u062f\u0631\u064b\u0627 \u0645\u0627 \u064a\u062a\u0633\u0628\u0628 \u0627\u0644\u0625\u0641\u0631\u0627\u0637 \u0641\u064a \u062a\u062d\u062f\u064a\u062f \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0641\u064a \u062d\u062f\u0648\u062b \u0645\u0634\u0627\u0643\u0644\u061b \u0628\u064a\u0646\u0645\u0627 \u064a\u0624\u062f\u064a \u0646\u0642\u0635 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0625\u0644\u0649 \u0643\u0648\u0627\u0628\u064a\u0633 \u062a\u0634\u063a\u064a\u0644\u064a\u0629.<\/p>\n<p><strong>\u062a\u062e\u062a\u0644\u0641 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0623\u062f\u0627\u0621 \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u062d\u0633\u0628 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0648\u0627\u0644\u0627\u062e\u062a\u0635\u0627\u0635 \u0627\u0644\u0642\u0636\u0627\u0626\u064a.<\/strong> \u062a\u0642\u064a\u064a\u0645 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u0644\u0647\u0628 \u0648\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u0648\u0627\u0646\u0628\u0639\u0627\u062b\u0627\u062a \u0627\u0644\u062f\u062e\u0627\u0646 \u0648\u0627\u0644\u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0647\u0627\u0644\u0648\u062c\u064a\u0646\u064a \u0628\u0646\u0627\u0621\u064b \u0639\u0644\u0649 \u0645\u0648\u0642\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0627\u0644\u0642\u0648\u0627\u0646\u064a\u0646 \u0627\u0644\u0645\u0639\u0645\u0648\u0644 \u0628\u0647\u0627 \u0648\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0639\u0648\u0627\u0642\u0628. \u062a\u0646\u0633\u064a\u0642 \u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u0645\u0639 \u0627\u0644\u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a\u0629 \u0627\u0644\u0634\u0627\u0645\u0644\u0629 \u0644\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062d\u0631\u0627\u0626\u0642 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0643\u0634\u0641 \u0648\u0627\u0644\u0625\u062e\u0645\u0627\u062f.<\/p>\n<p><strong>\u064a\u0645\u0646\u0639 \u0627\u0646\u0636\u0628\u0627\u0637 \u0627\u0644\u062a\u0648\u062c\u064a\u0647 \u0645\u0646 \u062d\u062f\u0648\u062b \u0645\u0634\u0627\u0643\u0644.<\/strong> \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0633\u0627\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644\u060c \u0648\u0645\u0631\u0627\u0639\u0627\u0629 \u062d\u062f\u0648\u062f \u0646\u0635\u0641 \u0642\u0637\u0631 \u0627\u0644\u0627\u0646\u062d\u0646\u0627\u0621\u060c \u0648\u062a\u0648\u0641\u064a\u0631 \u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0643\u0627\u0641\u064a. \u064a\u0645\u0646\u0639 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0625\u0636\u0627\u0641\u064a \u0627\u0644\u0645\u062a\u0648\u0627\u0636\u0639 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0633\u0646\u0648\u0627\u062a \u0645\u0646 \u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0627\u0644\u0623\u062e\u0637\u0627\u0621 \u0648\u0625\u0635\u0644\u0627\u062d\u0647\u0627 \u0648\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u062a\u0645\u0644\u0629.<\/p>\n<p><strong>\u062a\u062d\u062f\u062f \u062c\u0648\u062f\u0629 \u0627\u0644\u0625\u0646\u0647\u0627\u0621 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0627\u062a\u0635\u0627\u0644.<\/strong> \u062d\u062f\u062f \u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0637\u0631\u0641\u064a\u0629 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629\u060c \u0648\u0646\u0641\u0630 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u062c\u0639\u064a\u062f \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d\u060c \u0648\u0646\u0641\u0630 \u0648\u0635\u0644\u0627\u062a \u0625\u0646\u0647\u0627\u0621 \u0627\u0644\u062f\u0631\u0639 \u0627\u0644\u062a\u064a \u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0641\u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062a\u062f\u0631\u064a\u0639 \u0645\u0646 \u062e\u0644\u0627\u0644 \u062d\u062f\u0648\u062f \u0627\u0644\u0644\u0648\u062d\u0629.<\/p>\n<p><strong>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0635\u062d\u0629 \u0627\u0644\u0623\u062f\u0627\u0621.<\/strong> \u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u0627 \u0642\u0628\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0648\u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u062a\u062c\u0631\u064a\u0628\u064a \u064a\u0643\u062a\u0634\u0641 \u0627\u0644\u0639\u064a\u0648\u0628 \u0642\u0628\u0644 \u0623\u0646 \u062a\u062a\u0633\u0628\u0628 \u0641\u064a \u0645\u0634\u0627\u0643\u0644 \u062a\u0634\u063a\u064a\u0644\u064a\u0629. \u062a\u0648\u062b\u064a\u0642 \u0627\u0644\u0646\u062a\u0627\u0626\u062c \u0644\u0644\u0631\u062c\u0648\u0639 \u0625\u0644\u064a\u0647\u0627 \u0648\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644\u064a\u0629.<\/p>\n<p>\u0648\u062a\u0645\u062b\u0644 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u062c\u0632\u0621\u064b\u0627 \u0635\u063a\u064a\u0631\u064b\u0627 \u0645\u0646 \u062a\u0643\u0627\u0644\u064a\u0641 \u0645\u0634\u0631\u0648\u0639 \u0644\u0648\u062d\u0629 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637\u060c \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u0624\u062b\u0631 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0639\u0644\u0649 \u0627\u0644\u0646\u062c\u0627\u062d \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a. \u0648\u064a\u0624\u062f\u064a \u0627\u0633\u062a\u062b\u0645\u0627\u0631 \u0627\u0644\u0627\u0647\u062a\u0645\u0627\u0645 \u0627\u0644\u0647\u0646\u062f\u0633\u064a \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0648\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u0648\u0627\u062f \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0625\u0644\u0649 \u062a\u062d\u0642\u064a\u0642 \u0639\u0648\u0627\u0626\u062f \u0637\u0648\u0627\u0644 \u0639\u0645\u0631 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0630\u064a \u064a\u062a\u0631\u0627\u0648\u062d \u0628\u064a\u0646 30 \u064840 \u0639\u0627\u0645\u0627\u064b \u0645\u0646 \u0627\u0644\u062e\u062f\u0645\u0629.<\/p>\n<h2>\u0627\u0644\u0645\u0648\u0627\u0631\u062f \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629<\/h2>\n<ul>'\u0646' \u0646<\/p>\n<li><a href=\"https:\/\/xbrele.com\/ar\/switchgear-component-manufacturers-buyer-guide\/\">\u062f\u0644\u064a\u0644 \u0645\u0634\u062a\u0631\u064a \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/switchgear\/\">\u0623\u0633\u0627\u0633\u064a\u0627\u062a \u062a\u0635\u0645\u064a\u0645 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/switchgear-parts\/\">\u0623\u062c\u0632\u0627\u0621 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u0639\u0632\u0644<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/vacuum-contactor\/\">\u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0627\u0644\u0639\u0627\u0628\u0631 \u0644\u0645\u0648\u0635\u0644 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0626\u064a<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker\/\">\u062d\u0627\u0641\u0638\u0629 \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/99635\" target=\"_blank\" rel=\"noopener\">\u0635\u0641\u062d\u0629 \u0645\u0646\u0634\u0648\u0631 IEC 62271-100<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u0627\u062e\u062a\u0631 \u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0644\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637 \u0639\u0646 \u0637\u0631\u064a\u0642 \u0627\u0644\u062a\u062f\u0631\u064a\u0639\u060c \u0648\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u062d\u0631\u0627\u0626\u0642\u060c \u0648\u0627\u0644\u062a\u0648\u062c\u064a\u0647\u060c \u0648\u0627\u0644\u0625\u0646\u0647\u0627\u0621\u060c \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u060c \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u0648\u0627\u0641\u0642 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a (EMC).<\/p>","protected":false},"author":3,"featured_media":3674,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3679","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/3679","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=3679"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/3679\/revisions"}],"predecessor-version":[{"id":4113,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/3679\/revisions\/4113"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/3674"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=3679"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=3679"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=3679"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}