{"id":3709,"date":"2026-05-04T09:00:00","date_gmt":"2026-05-04T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3709"},"modified":"2026-05-31T05:59:22","modified_gmt":"2026-05-31T05:59:22","slug":"moisture-transformer-oil-paper-ppm-relative-saturation-dry-out","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/moisture-transformer-oil-paper-ppm-relative-saturation-dry-out\/","title":{"rendered":"\u0634\u0631\u062d \u0631\u0637\u0648\u0628\u0629 \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a: \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a"},"content":{"rendered":"<h2>\u0645\u0642\u062f\u0645\u0629: \u0627\u0644\u0645\u062f\u0645\u0631 \u0627\u0644\u0635\u0627\u0645\u062a \u0644\u0639\u0632\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/h2>\n<p>\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0647\u064a \u0623\u0643\u062b\u0631 \u0627\u0644\u0645\u0644\u0648\u062b\u0627\u062a \u0627\u0646\u062a\u0634\u0627\u0631\u064b\u0627 \u0648\u062a\u062f\u0645\u064a\u0631\u064b\u0627 \u0627\u0644\u062a\u064a \u062a\u0624\u062b\u0631 \u0639\u0644\u0649 \u0623\u0646\u0638\u0645\u0629 \u0639\u0632\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0645\u062a\u0648\u0633\u0637\u0629 \u0627\u0644\u062c\u0647\u062f. \u0628\u0639\u062f 18 \u0639\u0627\u0645\u064b\u0627 \u0645\u0646 \u062a\u0634\u062e\u064a\u0635 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0641\u064a \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0627\u0644\u0645\u0631\u0627\u0641\u0642\u060c \u0634\u0647\u062f\u062a \u0639\u0646 \u0643\u062b\u0628 \u0643\u064a\u0641 \u062a\u0624\u062f\u064a \u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u062a\u064a \u064a\u0633\u0627\u0621 \u0641\u0647\u0645\u0647\u0627 \u0625\u0644\u0649 \u0642\u0631\u0627\u0631\u0627\u062a \u0643\u0627\u0631\u062b\u064a\u0629 - \u0633\u0648\u0627\u0621 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0645\u0628\u0643\u0631 \u0644\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0635\u0627\u0644\u062d\u0629 \u0644\u0644\u062e\u062f\u0645\u0629 \u0623\u0648 \u0627\u0633\u062a\u0645\u0631\u0627\u0631 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u0639\u0644\u0649 \u062d\u0627\u0641\u0629 \u0627\u0644\u0641\u0634\u0644.<\/p>\n<p>\u064a\u0639\u062a\u0645\u062f \u0646\u0638\u0627\u0645 \u0639\u0632\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0639\u0644\u0649 \u0627\u0644\u0639\u0644\u0627\u0642\u0629 \u0627\u0644\u062a\u0622\u0632\u0631\u064a\u0629 \u0628\u064a\u0646 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0645\u0639\u062f\u0646\u064a (\u0623\u0648 \u0627\u0644\u0633\u0648\u0627\u0626\u0644 \u0627\u0644\u0628\u062f\u064a\u0644\u0629) \u0648\u0648\u0631\u0642 \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632. \u0648\u064a\u0648\u0641\u0631 \u0627\u0644\u0632\u064a\u062a \u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0648\u0646\u0642\u0644 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u064a\u063a\u0644\u0641 \u0627\u0644\u0648\u0631\u0642 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0648\u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0627\u0644\u062e\u0644\u0648\u0635 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0648\u062a\u0624\u062b\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0644\u0649 \u0643\u0644\u062a\u0627 \u0627\u0644\u0648\u0638\u064a\u0641\u062a\u064a\u0646 \u0641\u064a \u0648\u0642\u062a \u0648\u0627\u062d\u062f: \u0641\u0647\u064a \u062a\u0642\u0644\u0644 \u0645\u0646 \u062c\u0647\u062f \u0627\u0644\u0627\u0646\u0647\u064a\u0627\u0631 \u0627\u0644\u0639\u0627\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u0632\u064a\u062a\u060c \u0648\u062a\u0633\u0631\u0639 \u0645\u0646 \u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u0642\u0627\u062f\u0645 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0644\u0644\u0648\u0631\u0642\u060c \u0648\u062a\u062a\u064a\u062d \u0646\u0634\u0627\u0637 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a \u0628\u062a\u0631\u0643\u064a\u0632\u0627\u062a \u0645\u0646\u062e\u0641\u0636\u0629 \u0628\u0634\u0643\u0644 \u0645\u062f\u0647\u0634.<\/p>\n<p>\u0625\u0646 \u0641\u0647\u0645 \u0642\u064a\u0627\u0633 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0644\u064a\u0633 \u0645\u062c\u0631\u062f \u0623\u0645\u0631 \u0623\u0643\u0627\u062f\u064a\u0645\u064a - \u0641\u0647\u0648 \u064a\u0624\u062b\u0631 \u0628\u0634\u0643\u0644 \u0645\u0628\u0627\u0634\u0631 \u0639\u0644\u0649 \u0645\u064a\u0632\u0627\u0646\u064a\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u062c\u062f\u0648\u0644\u0629 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0648\u0627\u0633\u062a\u0631\u0627\u062a\u064a\u062c\u064a\u0627\u062a \u0625\u0637\u0627\u0644\u0629 \u0639\u0645\u0631 \u0627\u0644\u0623\u0635\u0648\u0644. \u062a\u0648\u0641\u0631 \u0647\u0630\u0647 \u0627\u0644\u0645\u0642\u0627\u0644\u0629 \u0627\u0644\u0623\u0633\u0627\u0633 \u0627\u0644\u0641\u0646\u064a \u0644\u062a\u0641\u0633\u064a\u0631 \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d\u060c \u0648\u0627\u062e\u062a\u064a\u0627\u0631 \u0637\u0631\u0642 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u0645\u0646\u0627\u0633\u0628\u0629\u060c \u0648\u0643\u062a\u0627\u0628\u0629 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062d\u0645\u064a \u0627\u0633\u062a\u062b\u0645\u0627\u0631\u0643.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature.webp\" alt=\"\u0631\u0633\u0645 \u0628\u064a\u0627\u0646\u064a \u064a\u0648\u0636\u062d \u0627\u0631\u062a\u0641\u0627\u0639 \u062d\u062f \u062a\u0634\u0628\u0639 \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0627\u0644\u0645\u0627\u0621 \u0645\u0639 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0645\u0639 \u062a\u062d\u062f\u064a\u062f 18 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0639\u0646\u062f \u0646\u0642\u0637\u062a\u064a\u0646 RS%\" class=\"wp-image-3705\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u064a\u0631\u062a\u0641\u0639 \u062d\u062f \u0627\u0644\u062a\u0634\u0628\u0639 \u0641\u064a \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0645\u0639\u062f\u0646\u064a \u0628\u0634\u0643\u0644 \u062d\u0627\u062f \u0645\u0639 \u0627\u0631\u062a\u0641\u0627\u0639 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644 \u0646\u0641\u0633 \u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0645\u0637\u0644\u0642\u0629 \u0644\u0644\u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u062a\u0645\u062b\u0644 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u062a\u0634\u0628\u0639 \u0646\u0633\u0628\u064a\u0629 \u0645\u062e\u062a\u0644\u0641\u0629 \u0625\u0644\u0649 \u062d\u062f \u0643\u0628\u064a\u0631 \u0627\u0639\u062a\u0645\u0627\u062f\u064b\u0627 \u0639\u0644\u0649 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0632\u064a\u062a \u0639\u0646\u062f \u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0629.<\/figcaption><\/figure>\n<h2>\u0641\u0647\u0645 \u0642\u064a\u0627\u0633 \u0627\u0644\u0631\u0637\u0648\u0628\u0629: \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0642\u0627\u0628\u0644 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a<\/h2>\n<h3>\u0623\u062c\u0632\u0627\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 (\u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646): \u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u0637\u0644\u0642<\/h3>\n<p>\u062a\u0645\u062b\u0644 \u0627\u0644\u0623\u062c\u0632\u0627\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0628\u0627\u0644\u0648\u0632\u0646 (\u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0623\u0648 \u0645\u0644\u063a\u0645\/\u0643\u063a\u0645) \u0627\u0644\u0643\u0645\u064a\u0629 \u0627\u0644\u0645\u0637\u0644\u0642\u0629 \u0645\u0646 \u0627\u0644\u0645\u0627\u0621 \u0627\u0644\u0630\u0627\u0626\u0628 \u0641\u064a \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a. \u062a\u0642\u064a\u0633 \u0645\u0639\u0627\u064a\u0631\u0629 \u0643\u0627\u0631\u0644 \u0641\u064a\u0634\u0631 - \u0648\u0647\u064a \u0637\u0631\u064a\u0642\u0629 \u0645\u062e\u062a\u0628\u0631\u064a\u0629 \u0642\u064a\u0627\u0633\u064a\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0640 ASTM D1533 - \u0647\u0630\u0627 \u0645\u0628\u0627\u0634\u0631\u0629\u064b \u0639\u0646 \u0637\u0631\u064a\u0642 \u062a\u0641\u0627\u0639\u0644 \u0627\u0644\u0645\u0627\u0621 \u0645\u0639 \u0627\u0644\u064a\u0648\u062f \u0641\u064a \u0645\u062d\u0644\u0648\u0644 \u0627\u0644\u0645\u064a\u062b\u0627\u0646\u0648\u0644.<\/p>\n<p>\u064a\u062e\u0628\u0631\u0643 \u0642\u064a\u0627\u0633 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0628\u0643\u0645\u064a\u0629 \u0627\u0644\u0645\u0627\u0621 \u0627\u0644\u0645\u0648\u062c\u0648\u062f\u0629 \u0648\u0644\u0643\u0646\u0647 \u0644\u0627 \u064a\u0643\u0634\u0641 \u0634\u064a\u0626\u064b\u0627 \u0639\u0646 \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0644\u0644\u0632\u064a\u062a \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0646\u0642\u0637\u0629 \u062a\u0634\u0628\u0639\u0647. \u0648\u064a\u062b\u0628\u062a \u0647\u0630\u0627 \u0627\u0644\u062a\u0645\u064a\u064a\u0632 \u0623\u0646\u0647 \u0623\u0645\u0631 \u0628\u0627\u0644\u063a \u0627\u0644\u0623\u0647\u0645\u064a\u0629 \u0644\u0623\u0646 \u0627\u0644\u0632\u064a\u0648\u062a \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0644\u0647\u0627 \u062e\u0635\u0627\u0626\u0635 \u0630\u0648\u0628\u0627\u0646 \u0641\u064a \u0627\u0644\u0645\u0627\u0621 \u0645\u062e\u062a\u0644\u0641\u0629 \u0625\u0644\u0649 \u062d\u062f \u0643\u0628\u064a\u0631.<\/p>\n<p><strong>\u0627\u0644\u0630\u0648\u0628\u0627\u0646 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a \u0644\u0644\u0631\u0637\u0648\u0628\u0629 \u062d\u0633\u0628 \u0646\u0648\u0639 \u0627\u0644\u0632\u064a\u062a \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 25 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629:<\/strong><br \/>\n- \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0645\u0639\u062f\u0646\u064a: 55-65 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0639\u0646\u062f \u0627\u0644\u062a\u0634\u0628\u0639<br \/>\n- \u0627\u0644\u0625\u0633\u062a\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a (FR3): 1,100+ \u062c\u0632\u0621 \u0645\u0646 \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0639\u0646\u062f \u0627\u0644\u062a\u0634\u0628\u0639<br \/>\n- \u0627\u0644\u0625\u0633\u062a\u0631 \u0627\u0644\u0627\u0635\u0637\u0646\u0627\u0639\u064a: 2,700 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0639\u0646\u062f \u0627\u0644\u062a\u0634\u0628\u0639<\/p>\n<p>\u062a\u0645\u062b\u0644 \u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u062a\u064a \u062a\u0628\u0644\u063a 35 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0641\u064a \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0645\u0639\u062f\u0646\u064a \u062d\u0648\u0627\u0644\u064a 601 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0646 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a 601 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a - \u0648\u0647\u0648 \u0645\u0627 \u064a\u0645\u062b\u0644 \u0645\u0635\u062f\u0631 \u0642\u0644\u0642 \u0628\u0627\u0644\u063a. \u0648\u062a\u0645\u062b\u0644 \u0646\u0641\u0633 \u0627\u0644 35 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0641\u064a \u0627\u0644\u0625\u0633\u062a\u0631 \u0627\u0644\u0637\u0628\u064a\u0639\u064a \u0645\u0627 \u064a\u0642\u0631\u0628 \u0645\u0646 3% \u062a\u0634\u0628\u0639 \u0646\u0633\u0628\u064a - \u0648\u0647\u0648 \u0623\u0645\u0631 \u0645\u0642\u0628\u0648\u0644 \u062a\u0645\u0627\u0645\u064b\u0627. \u0628\u062f\u0648\u0646 \u0641\u0647\u0645 \u0647\u0630\u0647 \u0627\u0644\u0639\u0644\u0627\u0642\u0629\u060c \u062a\u0635\u0628\u062d \u0642\u0631\u0627\u0631\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u062a\u0639\u0633\u0641\u064a\u0629 \u0628\u0634\u0643\u0644 \u062e\u0637\u064a\u0631.<\/p>\n<h3>\u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a (RS%): \u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0648\u0638\u064a\u0641\u064a<\/h3>\n<p>\u064a\u0639\u0628\u0631 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0639\u0646 \u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0643\u0646\u0633\u0628\u0629 \u0645\u0626\u0648\u064a\u0629 \u0645\u0646 \u0633\u0639\u0629 \u062a\u0634\u0628\u0639 \u0627\u0644\u0632\u064a\u062a \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0642\u064a\u0627\u0633. \u064a\u0631\u062a\u0628\u0637 \u0647\u0630\u0627 \u0627\u0644\u0642\u064a\u0627\u0633 \u0645\u0628\u0627\u0634\u0631\u0629 \u0628\u0640<\/p>\n<ul>\n<li><strong>\u0645\u062e\u0627\u0637\u0631 \u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0645\u064a\u0627\u0647 \u0627\u0644\u062d\u0631\u0629<\/strong>: \u0623\u0639\u0644\u0649 \u0645\u0646 100% RS\u060c \u064a\u062a\u0631\u0633\u0628 \u0627\u0644\u0645\u0627\u0621 \u062e\u0627\u0631\u062c\u0627\u064b<\/li>\n<li><strong>\u0627\u062d\u062a\u0645\u0627\u0644 \u0627\u0644\u0627\u0646\u0647\u064a\u0627\u0631 \u0627\u0644\u0639\u0627\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/strong>: \u064a\u0632\u064a\u062f \u0623\u0636\u0639\u0627\u0641\u064b\u0627 \u0645\u0636\u0627\u0639\u0641\u0629 \u0641\u0648\u0642 30% RS<\/li>\n<li><strong>\u0633\u0644\u0648\u0643 \u0647\u062c\u0631\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/strong>: \u062a\u062d\u062f\u064a\u062f \u0627\u062a\u062c\u0627\u0647 \u0648\u0645\u0639\u062f\u0644 \u062d\u0631\u0643\u0629 \u0627\u0644\u0645\u064a\u0627\u0647 \u0628\u064a\u0646 \u0627\u0644\u0632\u064a\u062a \u0648\u0627\u0644\u0648\u0631\u0642<\/li>\n<\/ul>\n<p>\u062a\u0642\u064a\u0633 \u0623\u062c\u0647\u0632\u0629 \u0627\u0633\u062a\u0634\u0639\u0627\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0633\u0639\u0648\u064a\u0629 \u0627\u0644\u062d\u062f\u064a\u062b\u0629 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0645\u0628\u0627\u0634\u0631\u0629\u064b \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0645\u0645\u0627 \u064a\u0648\u0641\u0631 \u0646\u0638\u0631\u0629 \u062b\u0627\u0642\u0628\u0629 \u0641\u064a \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u062d\u0642\u064a\u0642\u064a \u0644\u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u064a\u062a\u0637\u0644\u0628 \u062a\u062d\u0648\u064a\u0644 RS% \u0625\u0644\u0649 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0639\u0631\u0641\u0629 \u0645\u0646\u062d\u0646\u0649 \u062a\u0634\u0628\u0639 \u0627\u0644\u0632\u064a\u062a \u0648\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0639\u0646\u062f \u0627\u0644\u0642\u064a\u0627\u0633.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 (%)<\/th>\n<th>\u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u062d\u0627\u0644\u0629<\/th>\n<th>\u062a\u0623\u062b\u064a\u0631 \u0627\u0644\u062d\u064a\u0627\u0629 \u0627\u0644\u0645\u062a\u0648\u0642\u0639\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>&lt;1.0%<\/td>\n<td>\u0645\u0645\u062a\u0627\u0632 (\u062c\u062f\u064a\u062f\/\u062c\u0627\u0641)<\/td>\n<td>\u0639\u0645\u0631 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0643\u0627\u0645\u0644<\/td>\n<\/tr>\n<tr>\n<td>1.0 - 2.0%<\/td>\n<td>\u062c\u064a\u062f<\/td>\n<td>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0645\u0646 \u0627\u0644\u062a\u0633\u0627\u0631\u0639<\/td>\n<\/tr>\n<tr>\n<td>2.0 - 3.0%<\/td>\n<td>\u0645\u0639\u062a\u062f\u0644<\/td>\n<td>2-4 \u00d7 \u062a\u0633\u0631\u064a\u0639 \u0627\u0644\u0634\u064a\u062e\u0648\u062e\u0629<\/td>\n<\/tr>\n<tr>\n<td>3.0 - 4.0%<\/td>\n<td>\u0628\u062e\u0635\u0648\u0635<\/td>\n<td>5-10 \u00d7 \u062a\u0633\u0631\u064a\u0639 \u0627\u0644\u0634\u064a\u062e\u0648\u062e\u0629<\/td>\n<\/tr>\n<tr>\n<td>&gt; 4.0%<\/td>\n<td>\u062d\u0631\u062c<\/td>\n<td>\u064a\u0644\u0632\u0645 \u0627\u0644\u062a\u062f\u062e\u0644 \u0627\u0644\u0641\u0648\u0631\u064a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u064a\u062a\u0637\u0644\u0628 \u062a\u0642\u064a\u064a\u0645 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0637\u0631\u0642\u064b\u0627 \u063a\u064a\u0631 \u0645\u0628\u0627\u0634\u0631\u0629 \u0644\u0623\u0646 \u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0627\u062a \u0627\u0644\u0645\u0628\u0627\u0634\u0631\u0629 \u064a\u062f\u0645\u0631 \u0627\u0644\u0639\u0632\u0644. \u0648\u062a\u0648\u0641\u0631 \u062d\u0633\u0627\u0628\u0627\u062a \u0627\u0644\u062a\u0648\u0627\u0632\u0646 \u0645\u0646 \u0639\u064a\u0646\u0627\u062a \u0627\u0644\u0632\u064a\u062a \u0639\u0646\u062f \u062f\u0631\u062c\u0627\u062a \u062d\u0631\u0627\u0631\u0629 \u0645\u0639\u0631\u0648\u0641\u0629\u060c \u0625\u0644\u0649 \u062c\u0627\u0646\u0628 \u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0633\u062a\u062c\u0627\u0628\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0639\u0627\u0632\u0644 (DFR)\u060c \u062a\u0642\u062f\u064a\u0631\u0627\u062a \u0645\u0648\u062b\u0648\u0642\u0629.<\/p>\n<h3>\u062f\u064a\u0646\u0627\u0645\u064a\u0643\u064a\u0627\u062a \u0647\u062c\u0631\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/h3>\n<p>\u0623\u062b\u0646\u0627\u0621 \u062f\u0648\u0631\u0627\u062a \u0627\u0644\u062a\u062d\u0645\u064a\u0644\u060c \u062a\u062a\u0646\u0641\u0633 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u062f\u0627\u062e\u0644 \u0648\u062e\u0627\u0631\u062c \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0647\u0627. \u064a\u0645\u062a\u0635 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0627\u062e\u0646 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0646 \u0627\u0644\u0648\u0631\u0642 \u0623\u062b\u0646\u0627\u0621 \u0630\u0631\u0648\u0629 \u0627\u0644\u062a\u062d\u0645\u064a\u0644\u061b \u0648\u064a\u0637\u0644\u0642 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0628\u0627\u0631\u062f \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0631\u0629 \u0623\u062e\u0631\u0649 \u0623\u062b\u0646\u0627\u0621 \u0641\u062a\u0631\u0627\u062a \u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0627\u0644\u062e\u0641\u064a\u0641. \u0647\u0630\u0647 \u0627\u0644\u0647\u062c\u0631\u0629 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u0629 \u062a\u0648\u0632\u0639 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u062c\u0645\u064a\u0639 \u0623\u0646\u062d\u0627\u0621 \u0646\u0638\u0627\u0645 \u0627\u0644\u0639\u0632\u0644 \u0628\u0645\u0631\u0648\u0631 \u0627\u0644\u0648\u0642\u062a.<\/p>\n<p>\u062a\u062a\u0635\u0631\u0641 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0645\u062e\u062a\u0648\u0645\u0629 \u0648\u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u0627\u0644\u0645\u062d\u0627\u0641\u0638 \u0628\u0634\u0643\u0644 \u0645\u062e\u062a\u0644\u0641. \u0641\u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062d\u0627\u0641\u0638\u0629 \u0627\u0644\u0645\u0632\u0648\u062f\u0629 \u0628\u0623\u062c\u0647\u0632\u0629 \u062a\u0646\u0641\u0633 \u0647\u0644\u0627\u0645 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0627 \u062a\u0642\u0644\u0644 \u0645\u0646 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u0627\u0644\u063a\u0644\u0627\u0641 \u0627\u0644\u062c\u0648\u064a \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062a\u0637\u0644\u0628 \u0635\u064a\u0627\u0646\u0629 \u0647\u0644\u0627\u0645\u064a\u0629 \u062f\u0624\u0648\u0628\u0629. \u062a\u0645\u0646\u0639 \u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0645\u063a\u0637\u0627\u0629 \u0628\u0627\u0644\u0646\u064a\u062a\u0631\u0648\u062c\u064a\u0646 \u0627\u0644\u0645\u062d\u0643\u0645 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u062f\u062e\u0648\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u062a\u0645\u0627\u0645\u064b\u0627 \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062d\u0628\u0633 \u0623\u064a \u0631\u0637\u0648\u0628\u0629 \u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u062a\u0642\u0627\u062f\u0645 \u0627\u0644\u0648\u0631\u0642.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart.webp\" alt=\"\u0645\u062e\u0637\u0637 \u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u064a\u0646 \u0637\u0631\u0642 \u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0627\u062e\u0646\u060c \u0648\u0627\u0644\u062a\u0633\u062e\u064a\u0646 \u0645\u0646\u062e\u0641\u0636 \u0627\u0644\u062a\u0631\u062f\u062f\u060c \u0648\u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0641\u064a \u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u0628\u062e\u0627\u0631\" class=\"wp-image-3707\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u064a\u0639\u062a\u0645\u062f \u0627\u062e\u062a\u064a\u0627\u0631 \u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0639\u0644\u0649 \u0634\u062f\u0629 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642\u060c \u0648\u0646\u0627\u0641\u0630\u0629 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0645\u062a\u0627\u062d\u0629\u060c \u0648\u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0644\u0644\u0645\u0648\u0642\u0639\u061b \u064a\u062d\u0642\u0642 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0641\u064a \u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u0628\u062e\u0627\u0631 \u0623\u0639\u0645\u0642 \u0627\u062e\u062a\u0631\u0627\u0642 \u0648\u0644\u0643\u0646\u0647 \u064a\u062a\u0637\u0644\u0628 \u0638\u0631\u0648\u0641 \u0648\u0631\u0634\u0629 \u0639\u0645\u0644.<\/figcaption><\/figure>\n<h2>\u062a\u0641\u0633\u064a\u0631 \u0646\u062a\u0627\u0626\u062c \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629: \u0625\u0637\u0627\u0631 \u0639\u0645\u0644 \u0639\u0645\u0644\u064a<\/h2>\n<h3>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0648\u0642\u0639\u0627\u062a \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629<\/h3>\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u063a\u0627\u062f\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u062f\u064a\u062f\u0629 \u0627\u0644\u0645\u0635\u0646\u0639 \u0628\u0631\u0637\u0648\u0628\u0629 \u0632\u064a\u062a \u0623\u0642\u0644 \u0645\u0646 10 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0648\u0631\u0637\u0648\u0628\u0629 \u0648\u0631\u0642 \u0623\u0642\u0644 \u0645\u0646 0.51 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646. \u0627\u0644\u0648\u0627\u0642\u0639 \u064a\u062e\u062a\u0644\u0641 \u0641\u064a \u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0623\u062d\u064a\u0627\u0646 - \u0644\u0642\u062f \u0627\u0633\u062a\u0644\u0645\u062a \u0648\u062d\u062f\u0627\u062a \u062a\u062d\u062a\u0648\u064a \u0639\u0644\u0649 \u0623\u0643\u062b\u0631 \u0645\u0646 25 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0646 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0641\u064a \u0627\u0644\u062e\u0627\u0631\u062c \u0627\u0644\u062a\u064a \u0623\u0639\u0637\u062a \u0627\u0644\u0623\u0648\u0644\u0648\u064a\u0629 \u0644\u062c\u062f\u0627\u0648\u0644 \u0627\u0644\u0634\u062d\u0646 \u0639\u0644\u0649 \u0627\u0644\u062c\u0641\u0627\u0641 \u0627\u0644\u0645\u0646\u0627\u0633\u0628. \u0625\u0646 \u0648\u0636\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0648\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u062d\u0642\u0642 \u064a\u062d\u0645\u064a \u0645\u0646 \u062a\u0648\u0631\u064a\u062b \u0627\u062e\u062a\u0635\u0627\u0631\u0627\u062a \u0627\u0644\u062c\u0648\u062f\u0629 \u0644\u0634\u062e\u0635 \u0622\u062e\u0631.<\/p>\n<p>\u062a\u062a\u0631\u0627\u0643\u0645 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0646 \u0645\u0635\u0627\u062f\u0631 \u0645\u062a\u0639\u062f\u062f\u0629 \u0641\u064a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u0645\u0636\u0649 \u0639\u0644\u064a\u0647\u0627 \u0639\u0645\u0631 \u0627\u0644\u062e\u062f\u0645\u0629:<br \/>\n- \u0627\u0644\u062a\u0646\u0641\u0633 \u0641\u064a \u0627\u0644\u063a\u0644\u0627\u0641 \u0627\u0644\u062c\u0648\u064a (\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062d\u0641\u0638)<br \/>\n- \u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u062d\u0634\u064a\u0629 \u0648\u0645\u0627\u0646\u0639 \u0627\u0644\u062a\u0633\u0631\u0628<br \/>\n- \u062a\u062d\u0644\u0644 \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632 (\u064a\u0646\u062a\u062c \u0627\u0644\u0645\u0627\u0621 \u0643\u0645\u0646\u062a\u062c \u062b\u0627\u0646\u0648\u064a)<br \/>\n- \u0646\u0648\u0627\u062a\u062c \u0623\u0643\u0633\u062f\u0629 \u0627\u0644\u0632\u064a\u062a<\/p>\n<h3>\u0627\u0644\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0645\u0635\u062d\u062d \u0644\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629<\/h3>\n<p>\u062a\u0628\u0644\u063a \u0646\u062a\u0627\u0626\u062c \u0627\u0644\u0645\u062e\u062a\u0628\u0631 \u0639\u0646 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 (\u0639\u0627\u062f\u0629\u064b 20-25 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629)\u060c \u0648\u0627\u0644\u062a\u064a \u0642\u062f \u062a\u062e\u062a\u0644\u0641 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0639\u0646 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0627\u062a. \u0627\u0637\u0644\u0628 \u062a\u062f\u0648\u064a\u0646 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0627\u062a \u0641\u064a \u0646\u0645\u0648\u0630\u062c \u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u0639\u0647\u062f\u0629 \u0644\u062a\u0645\u0643\u064a\u0646 \u0627\u0644\u062a\u0641\u0633\u064a\u0631 \u0627\u0644\u0635\u062d\u064a\u062d.<\/p>\n<p>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u0633\u062a\u0634\u0639\u0631\u0627\u062a \u0627\u0644\u0645\u062a\u0635\u0644\u0629 \u0628\u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a \u0627\u0644\u062a\u064a \u062a\u0648\u0641\u0631 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u0629\u060c \u0636\u0639 \u0646\u0642\u0627\u0637 \u0636\u0628\u0637 \u0627\u0644\u0625\u0646\u0630\u0627\u0631 \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0645\u0639 \u0645\u0631\u0627\u0639\u0627\u0629 \u0627\u0644\u062a\u063a\u064a\u0631\u0627\u062a \u0641\u064a \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0639\u062a\u0645\u062f\u0629 \u0639\u0644\u0649 \u0627\u0644\u062d\u0645\u0644. \u064a\u062a\u062d\u0645\u0644 \u0627\u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u0630\u064a \u064a\u0639\u0645\u0644 \u0628\u0645\u062a\u0648\u0633\u0637 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0644\u0641 65 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0645\u062a\u0648\u0633\u0637 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0644\u0641 \u0623\u0639\u0644\u0649 \u0645\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u0630\u064a \u064a\u0639\u0645\u0644 \u0628\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 80 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0642\u0628\u0644 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u0649 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0627\u0644\u0645\u0643\u0627\u0641\u0626.<\/p>\n<h3>\u0627\u0644\u062c\u0645\u0639 \u0628\u064a\u0646 \u0637\u0631\u0642 \u0627\u0644\u062a\u0634\u062e\u064a\u0635 \u0627\u0644\u0645\u062a\u0639\u062f\u062f\u0629<\/h3>\n<p>\u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u0639\u062a\u0645\u062f \u062a\u0642\u064a\u064a\u0645 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0644\u0649 \u0642\u064a\u0627\u0633 \u0648\u0627\u062d\u062f. \u064a\u0642\u0648\u0645 \u062e\u0628\u0631\u0627\u0621 \u0627\u0644\u062a\u0634\u062e\u064a\u0635 \u0627\u0644\u0645\u062a\u0645\u0631\u0633\u0648\u0646 \u0628\u0627\u0644\u062a\u062b\u0644\u064a\u062b:<\/p>\n<ol>\n<li><strong>\u0645\u0639\u0627\u064a\u0631\u0629 \u0643\u0627\u0631\u0644 \u0641\u064a\u0634\u0631<\/strong>: \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0645\u0637\u0644\u0642\u0629 \u0641\u064a \u0639\u064a\u0646\u0629 \u0627\u0644\u0632\u064a\u062a<\/li>\n<li><strong>\u0627\u0633\u062a\u062c\u0627\u0628\u0629 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0639\u0627\u0632\u0644 (DFR)<\/strong>: \u062a\u0642\u062f\u064a\u0631 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642<\/li>\n<li><strong>\u0645\u0633\u062a\u0634\u0639\u0631\u0627\u062a RS% \u0639\u0644\u0649 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a<\/strong>: \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062a\u0634\u0628\u0639 \u0641\u064a \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u062d\u0642\u064a\u0642\u064a<\/li>\n<li><strong>\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u063a\u0627\u0632 \u0627\u0644\u0645\u0630\u0627\u0628<\/strong>: \u064a\u0624\u0643\u062f \u0623\u0648 \u064a\u062f\u062d\u0636 \u0627\u0644\u0646\u0634\u0627\u0637 \u0627\u0644\u0645\u0631\u062a\u0628\u0637 \u0628\u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/li>\n<li><strong>\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629\/\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u062a\u0634\u062a\u062a\/\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u062a\u0634\u062a\u062a<\/strong>: \u062a\u0634\u064a\u0631 \u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u0645\u0631\u062a\u0641\u0639\u0629 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u062a\u0644\u0648\u062b<\/li>\n<\/ol>\n<p>\u064a\u0634\u064a\u0631 \u0627\u0644\u0627\u062e\u062a\u0644\u0627\u0641 \u0628\u064a\u0646 \u0627\u0644\u0637\u0631\u0642 \u0625\u0644\u0649 \u0648\u062c\u0648\u062f \u0623\u062e\u0637\u0627\u0621 \u0641\u064a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0623\u0648 \u0638\u0631\u0648\u0641 \u063a\u064a\u0631 \u0639\u0627\u062f\u064a\u0629 \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u062d\u0642\u064a\u0642.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart.webp\" alt=\"\u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u0627\u0646\u0633\u064a\u0627\u0628\u064a \u0644\u0644\u0642\u0631\u0627\u0631 \u0627\u0644\u062e\u0627\u0635 \u0628\u0642\u0628\u0648\u0644 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0646\u0627\u0621\u064b \u0639\u0644\u0649 \u0639\u062a\u0628\u0627\u062a \u0627\u0644\u0646\u0633\u0628\u0629 \u0627\u0644\u0645\u0626\u0648\u064a\u0629 \u0644\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a\" class=\"wp-image-3708\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u064a\u062a\u0631\u062c\u0645 \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u0627\u0646\u0633\u064a\u0627\u0628\u064a \u0644\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0642\u0627\u0626\u0645 \u0639\u0644\u0649 \u0627\u0644\u0639\u062a\u0628\u0629 \u0646\u062a\u0627\u0626\u062c \u0627\u062e\u062a\u0628\u0627\u0631 RS% \u0625\u0644\u0649 \u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0636\u062d\u0629\u060c \u0645\u0645\u0627 \u064a\u0632\u064a\u0644 \u0627\u0644\u063a\u0645\u0648\u0636 \u0645\u0646 \u0642\u0631\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0648\u0642\u064a\u0639 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0627\u0641\u0642\u0629 \u0628\u0639\u062f \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629.<\/figcaption><\/figure>\n<h2>\u0637\u0631\u0642 \u0627\u0644\u062a\u062c\u0641\u064a\u0641: \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0648\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/h2>\n<h3>\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0627\u062e\u0646<\/h3>\n<p>\u062a\u0645\u062b\u0644 \u0639\u0645\u0644\u064a\u0629 \u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0627\u062e\u0646 \u0623\u0642\u0644 \u0637\u0631\u0642 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u062c\u0631\u0627\u062d\u064a \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062e\u062f\u0645\u0629. \u0648\u062a\u062a\u0636\u0645\u0646 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0645\u0627 \u064a\u0644\u064a:<\/p>\n<ol>\n<li>\u062a\u0633\u062e\u064a\u0646 \u0627\u0644\u0632\u064a\u062a \u0625\u0644\u0649 70-80 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0641\u064a \u0648\u062d\u062f\u0629 \u0645\u0639\u0627\u0644\u062c\u0629 \u062e\u0627\u0631\u062c\u064a\u0629<\/li>\n<li>\u0627\u0644\u062f\u0648\u0631\u0627\u0646 \u0639\u0628\u0631 \u0627\u0644\u0645\u062d\u0648\u0644 \u0628\u0645\u0639\u062f\u0644 10-151 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a \u0641\u064a \u0627\u0644\u0633\u0627\u0639\u0629 \u0645\u0646 \u062d\u062c\u0645 \u0627\u0644\u062e\u0632\u0627\u0646<\/li>\n<li>\u0627\u0644\u0645\u0631\u0648\u0631 \u0639\u0628\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0628\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0628\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0623\u0648 \u0623\u0639\u0645\u062f\u0629 \u0627\u0644\u0645\u0646\u062e\u0644 \u0627\u0644\u062c\u0632\u064a\u0626\u064a<\/li>\n<li>\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0645\u062c\u0641\u0641 \u0625\u0644\u0649 \u0627\u0644\u0645\u062d\u0648\u0644<\/li>\n<\/ol>\n<p><strong>\u0627\u0644\u0641\u0639\u0627\u0644\u064a\u0629<\/strong>: \u064a\u0642\u0644\u0644 \u0645\u0646 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0632\u064a\u062a \u0625\u0644\u0649 \u0623\u0642\u0644 \u0645\u0646 10 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646\u061b \u062a\u0642\u0644\u064a\u0644 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0628\u0634\u0643\u0644 \u0645\u062d\u062f\u0648\u062f (\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u064a\u062a\u062d\u0633\u0646 \u0628\u0645\u0642\u062f\u0627\u0631 0.5-1.01 \u062c\u0632\u0621 \u0645\u0646 \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0646 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 2-4 \u0623\u0633\u0627\u0628\u064a\u0639 \u0645\u0646 \u0627\u0644\u062a\u062f\u0627\u0648\u0644 \u0627\u0644\u0645\u0633\u062a\u0645\u0631)<\/p>\n<p><strong>\u0623\u0641\u0636\u0644 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/strong>: \u0648\u062d\u062f\u0627\u062a \u0645\u0644\u0648\u062b\u0629 \u0628\u0634\u0643\u0644 \u0645\u0639\u062a\u062f\u0644 \u062d\u064a\u062b \u062a\u0638\u0644 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0623\u0642\u0644 \u0645\u0646 3%<\/p>\n<p><strong>\u0627\u0644\u0642\u064a\u0648\u062f<\/strong>: \u0644\u0627 \u064a\u0645\u0643\u0646 \u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0648\u0631\u0642 \u0627\u0644\u0645\u0634\u0628\u0639 \u0628\u0643\u062b\u0627\u0641\u0629\u061b \u0625\u0637\u0627\u0644\u0629 \u0627\u0644\u0645\u062f\u0629 \u062a\u0639\u0637\u0644 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629<\/p>\n<h3>\u0627\u0644\u062c\u0641\u0627\u0641 \u0628\u0627\u0644\u062a\u0641\u0631\u064a\u063a<\/h3>\n<p>\u062a\u0639\u0645\u0644 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0628\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0639\u0644\u0649 \u062a\u0633\u0631\u064a\u0639 \u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0646 \u0637\u0631\u064a\u0642 \u062a\u0642\u0644\u064a\u0644 \u062f\u0631\u062c\u0629 \u063a\u0644\u064a\u0627\u0646 \u0627\u0644\u0645\u0627\u0621 \u062f\u0627\u062e\u0644 \u0627\u0644\u0639\u0632\u0644. \u064a\u0648\u062c\u062f \u0646\u0648\u0639\u0627\u0646 \u0645\u062e\u062a\u0644\u0641\u0627\u0646:<\/p>\n<p><strong>\u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0628\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a<\/strong> \u064a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u062a\u0641\u0631\u064a\u063a \u0645\u0633\u062a\u0645\u0631 (0.5-5 \u062a\u0648\u0631) \u0639\u0644\u0649 \u0627\u0644\u062d\u0627\u0641\u0638\u0629 \u0623\u0648 \u0645\u0633\u0627\u062d\u0629 \u0628\u0637\u0627\u0646\u064a\u0629 \u0627\u0644\u0646\u064a\u062a\u0631\u0648\u062c\u064a\u0646 \u0623\u062b\u0646\u0627\u0621 \u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629. \u062a\u0646\u0627\u0633\u0628 \u0647\u0630\u0647 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u0644\u0627 \u064a\u0645\u0643\u0646 \u0625\u0644\u063a\u0627\u0621 \u062a\u0646\u0634\u064a\u0637\u0647\u0627 \u0644\u0641\u062a\u0631\u0627\u062a \u0637\u0648\u064a\u0644\u0629.<\/p>\n<p><strong>\u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0628\u0627\u0644\u0645\u0643\u0646\u0633\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/strong> \u064a\u062a\u0637\u0644\u0628 \u0625\u0644\u063a\u0627\u0621 \u062a\u0646\u0634\u064a\u0637 \u0648\u062a\u0635\u0631\u064a\u0641 \u0643\u0627\u0645\u0644. \u064a\u062a\u0645 \u062a\u0633\u062e\u064a\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u062e\u0627\u0631\u062c\u064a\u064b\u0627 \u0623\u062b\u0646\u0627\u0621 \u0648\u062c\u0648\u062f \u0627\u0644\u0645\u062d\u0648\u0644 \u062a\u062d\u062a \u062a\u0641\u0631\u064a\u063a \u0639\u0645\u064a\u0642 (&lt; 1 torr)\u060c \u0645\u0645\u0627 \u064a\u062c\u0628\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0646 \u0639\u0632\u0644 \u0627\u0644\u0648\u0631\u0642. \u062a\u062d\u0642\u0642 \u0647\u0630\u0647 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0623\u0642\u0644 \u0645\u0646 1.0% \u0639\u0646\u062f \u062a\u0646\u0641\u064a\u0630\u0647\u0627 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d.<\/p>\n<h3>\u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0641\u064a \u0637\u0648\u0631 \u0627\u0644\u0628\u062e\u0627\u0631<\/h3>\n<p>\u064a\u0645\u062b\u0644 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0641\u064a \u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u0628\u062e\u0627\u0631 \u0627\u0644\u0645\u0639\u064a\u0627\u0631 \u0627\u0644\u0630\u0647\u0628\u064a \u0644\u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0645\u0635\u0646\u0639 \u0648\u0627\u0644\u0645\u0633\u062a\u0648\u062f\u0639. \u0627\u0644\u0639\u0645\u0644\u064a\u0629:<\/p>\n<ol>\n<li>\u0625\u062f\u062e\u0627\u0644 \u0627\u0644\u0643\u064a\u0631\u0648\u0633\u064a\u0646 \u0645\u0646\u062e\u0641\u0636 \u0646\u0642\u0637\u0629 \u0627\u0644\u063a\u0644\u064a\u0627\u0646 \u0623\u0648 \u0645\u0630\u064a\u0628 \u0645\u0645\u0627\u062b\u0644 \u0641\u064a \u0634\u0643\u0644 \u0628\u062e\u0627\u0631<\/li>\n<li>\u064a\u062a\u0643\u062b\u0641 \u0627\u0644\u0628\u062e\u0627\u0631 \u0639\u0644\u0649 \u0623\u0633\u0637\u062d \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632 \u0627\u0644\u0623\u0643\u062b\u0631 \u0628\u0631\u0648\u062f\u0629\u060c \u0645\u0645\u0627 \u064a\u0624\u062f\u064a \u0625\u0644\u0649 \u062a\u0633\u062e\u064a\u0646 \u0627\u0644\u0639\u0632\u0644 \u0645\u0646 \u0627\u0644\u062f\u0627\u062e\u0644<\/li>\n<li>\u064a\u062a\u0628\u062e\u0631 \u0627\u0644\u0645\u0627\u0621 \u0641\u064a \u062a\u064a\u0627\u0631 \u0627\u0644\u0628\u062e\u0627\u0631<\/li>\n<li>\u062a\u0632\u064a\u0644 \u0627\u0644\u0645\u0643\u0646\u0633\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0628\u062e\u0627\u0631 \u0627\u0644\u0645\u062d\u0645\u0644 \u0628\u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/li>\n<li>\u062a\u062a\u0643\u0631\u0631 \u0627\u0644\u062f\u0648\u0631\u0627\u062a \u062d\u062a\u0649 \u064a\u062a\u062d\u0642\u0642 \u0627\u0644\u062c\u0641\u0627\u0641 \u0627\u0644\u0645\u0633\u062a\u0647\u062f\u0641<\/li>\n<\/ol>\n<p>\u062a\u062d\u0642\u0642 \u0647\u0630\u0647 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0623\u0642\u0644 \u0645\u0646 0.5% - \u0623\u064a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0639\u0632\u0644 \u0625\u0644\u0649 \u062d\u0627\u0644\u062a\u0647 \u0627\u0644\u062c\u062f\u064a\u062f\u0629 - \u0648\u0644\u0643\u0646\u0647\u0627 \u062a\u062a\u0637\u0644\u0628 \u0645\u0639\u062f\u0627\u062a \u0645\u062a\u062e\u0635\u0635\u0629 \u0648\u0639\u0627\u062f\u0629\u064b \u0645\u0627 \u062a\u062d\u062f\u062b \u0641\u0642\u0637 \u0623\u062b\u0646\u0627\u0621 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0623\u0648 \u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0641\u064a \u0627\u0644\u0645\u0635\u0646\u0639.<\/p>\n<h3>\u062d\u0642\u0646 \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u062c\u0627\u0641<\/h3>\n<p>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u0644\u0627 \u062a\u062a\u0648\u0641\u0631 \u0641\u064a\u0647\u0627 \u0645\u0639\u062f\u0627\u062a \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0647\u0648\u0627\u0621\u060c \u064a\u0648\u0641\u0631 \u0627\u0644\u062d\u0642\u0646 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 \u0628\u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u062c\u0627\u0641 \u0628\u062f\u064a\u0644\u0627\u064b \u0623\u0628\u0637\u0623 \u0648\u0644\u0643\u0646\u0647 \u0641\u0639\u0627\u0644. \u064a\u0642\u0648\u0645 \u0627\u0644\u0647\u0648\u0627\u0621 \u0630\u0648 \u062f\u0631\u062c\u0629 \u0627\u0644\u0646\u062f\u0649 (\u0646\u0642\u0637\u0629 \u0627\u0644\u0646\u062f\u0649 &lt; -40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629) \u0628\u0641\u0642\u0627\u0639\u0627\u062a \u0645\u0646 \u062e\u0644\u0627\u0644 \u0627\u0644\u0632\u064a\u062a\u060c \u0648\u064a\u0645\u062a\u0635 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u064a\u062e\u0631\u062c \u0645\u0646 \u062e\u0644\u0627\u0644 \u062a\u0646\u0641\u064a\u0633 \u0627\u0644\u0636\u063a\u0637 \u0623\u0648 \u0641\u062a\u062d\u0627\u062a \u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629.<\/p>\n<p><strong>\u0627\u0644\u0641\u0639\u0627\u0644\u064a\u0629<\/strong>: \u064a\u0635\u0644 \u0625\u0644\u0649 \u0627\u0644\u062a\u0648\u0627\u0632\u0646 \u0645\u0639 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0639\u0644\u0649 \u0645\u062f\u0649 4-8 \u0623\u0633\u0627\u0628\u064a\u0639\u061b \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0644\u0644\u0648\u0631\u0642 \u0639\u0627\u062f\u0629\u064b 1.5-2.5%<\/p>\n<p><strong>\u0623\u0641\u0636\u0644 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/strong>: \u0627\u0644\u0645\u0648\u0627\u0642\u0639 \u0627\u0644\u0646\u0627\u0626\u064a\u0629\u060c \u0623\u0648 \u0627\u0644\u062d\u0627\u0644\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0645\u064a\u0632\u0627\u0646\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u0648\u062f\u0629\u060c \u0623\u0648 \u0643\u0635\u064a\u0627\u0646\u0629 \u0628\u064a\u0646 \u0627\u0644\u062a\u062f\u062e\u0644\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/p>\n<hr \/>\n<h2>\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0643\u062a\u0627\u0628\u0629: \u062d\u0645\u0627\u064a\u0629 \u0627\u0633\u062a\u062b\u0645\u0627\u0631\u0643<\/h2>\n<h3>\u0645\u0639\u0627\u064a\u064a\u0631 \u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u062f\u064a\u062f\u0629<\/h3>\n<p>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0646\u0635 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0639\u0644\u0649 \u062d\u062f\u0648\u062f \u0648\u0627\u0636\u062d\u0629 \u0644\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0639 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u062d\u0642\u0642:<\/p>\n<blockquote>\n<p>\u201c\u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a 10 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0639\u0646\u062f \u0627\u062e\u062a\u0628\u0627\u0631\u0647 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0629 ASTM D1533 \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 20-25 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629. \u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0648\u0631\u0642\u064a\u060c \u0627\u0644\u0645\u0642\u062f\u0631 \u0639\u0646 \u0637\u0631\u064a\u0642 \u062d\u0633\u0627\u0628 \u0627\u0644\u062a\u0648\u0627\u0632\u0646 \u0623\u0648 \u0633\u062c\u0644\u0627\u062a \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629\u060c 0.51 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a \u0628\u0627\u0644\u0648\u0632\u0646. \u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0645 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u062d\u0642\u0642 \u0641\u064a \u063a\u0636\u0648\u0646 72 \u0633\u0627\u0639\u0629 \u0645\u0646 \u0627\u0644\u062a\u0633\u0644\u064a\u0645\u060c \u0645\u0639 \u0628\u0642\u0627\u0621 \u0627\u0644\u0645\u062d\u0648\u0644 \u0641\u064a \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u0644\u0645\u062f\u0629 24 \u0633\u0627\u0639\u0629 \u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0644 \u0642\u0628\u0644 \u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0629.\u201d<\/p>\n<\/blockquote>\n<p>\u062a\u0636\u0645\u064a\u0646 \u0639\u0648\u0627\u0642\u0628 \u0639\u062f\u0645 \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644: \u201c\u064a\u062c\u0628 \u0623\u0646 \u062a\u062e\u0636\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u062c\u0627\u0648\u0632 \u062d\u062f\u0648\u062f \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0644\u0644\u062a\u062c\u0641\u064a\u0641 \u062a\u062d\u062a \u0625\u0634\u0631\u0627\u0641 \u0627\u0644\u0645\u0635\u0646\u0639 \u0639\u0644\u0649 \u0646\u0641\u0642\u0629 \u0627\u0644\u0634\u0631\u0643\u0629 \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0642\u0628\u0644 \u0627\u0644\u0642\u0628\u0648\u0644.\u201d<\/p>\n<h3>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0642\u062f\u064a\u0645\u0629 \u0627\u0644\u062e\u062f\u0645\u0629<\/h3>\n<p>\u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062e\u0636\u0639 \u0644\u0644\u062a\u062c\u062f\u064a\u062f \u0623\u0648 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629:<\/p>\n<blockquote>\n<p>\u201c\u064a\u062c\u0628 \u0623\u0646 \u062a\u062d\u0642\u0642 \u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0632\u064a\u062a \u0623\u0642\u0644 \u0645\u0646 15 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0648\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 \u0623\u0642\u0644 \u0645\u0646 1.51 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646. \u0648\u064a\u062c\u0628 \u0623\u0646 \u064a\u0648\u0641\u0631 \u0627\u0644\u0645\u0642\u0627\u0648\u0644 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u064b \u0642\u0628\u0644\/\u0628\u0639\u062f \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0628\u0645\u0627 \u0641\u064a \u0630\u0644\u0643 \u0645\u0639\u0627\u064a\u0631\u0629 \u0643\u0627\u0631\u0644 \u0641\u064a\u0634\u0631 \u0648\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629 \u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a. \u0648\u064a\u062c\u0628 \u0623\u0646 \u062a\u0624\u062e\u0630 \u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0628\u0639\u062f 48 \u0633\u0627\u0639\u0629 \u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0644 \u0645\u0646 \u0627\u0643\u062a\u0645\u0627\u0644 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0644\u0644\u0633\u0645\u0627\u062d \u0628\u062a\u062b\u0628\u064a\u062a \u0627\u0644\u062a\u0648\u0627\u0632\u0646.\u201d<\/p>\n<\/blockquote>\n<h3>\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a<\/h3>\n<p>\u0639\u0646\u062f \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u0629 \u0644\u0644\u0631\u0637\u0648\u0628\u0629:<\/p>\n<blockquote>\n<p>\u201c\u064a\u062c\u0628 \u0623\u0646 \u062a\u0642\u064a\u0633 \u062d\u0633\u0627\u0633\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0628\u062f\u0642\u0629 \u00b1 3% RS \u0639\u0628\u0631 \u0646\u0637\u0627\u0642 0-100%. \u064a\u062c\u0628 \u0623\u0646 \u062a\u0639\u0648\u0636 \u0627\u0644\u062d\u0633\u0627\u0633\u0627\u062a \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u062a\u0644\u0642\u0627\u0626\u064a\u064b\u0627 \u0648\u062a\u062a\u0648\u0627\u0635\u0644 \u0639\u0628\u0631 Modbus RTU \u0623\u0648 IEC 61850. \u064a\u062c\u0628 \u062a\u0647\u064a\u0626\u0629 \u0646\u0642\u0627\u0637 \u0636\u0628\u0637 \u0627\u0644\u0625\u0646\u0630\u0627\u0631 \u0639\u0646\u062f 20% RS (\u062a\u062d\u0630\u064a\u0631) \u064830% RS (\u062d\u0631\u062c) \u0645\u0639 \u062a\u0635\u0641\u064a\u0629 \u0627\u0644\u062a\u0623\u062e\u064a\u0631 \u0627\u0644\u0632\u0645\u0646\u064a \u0644\u0645\u0646\u0639 \u0627\u0644\u0625\u0646\u0630\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0632\u0639\u062c\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0646\u062a\u0642\u0627\u0644\u0627\u062a \u0627\u0644\u062d\u0645\u0644.\u201d<\/p>\n<\/blockquote>\n<hr \/>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a\u0629: \u062f\u0631\u0648\u0633 \u0645\u0633\u062a\u0641\u0627\u062f\u0629 \u0645\u0646 \u062d\u0627\u0644\u0627\u062a \u0648\u0627\u0642\u0639\u064a\u0629<\/h2>\n<h3>\u062f\u0631\u0627\u0633\u0629 \u062d\u0627\u0644\u0629: \u0627\u0644\u0646\u062a\u064a\u062c\u0629 \u201c\u0627\u0644\u062c\u064a\u062f\u0629\u201d \u0627\u0644\u0645\u0636\u0644\u0644\u0629<\/h3>\n<p>\u062a\u0645 \u0627\u062e\u062a\u0628\u0627\u0631 \u0631\u0637\u0648\u0628\u0629 \u0645\u062d\u0648\u0644 \u0645\u062d\u0637\u0629 \u0641\u0631\u0639\u064a\u0629 \u0628\u0642\u0648\u0629 25 \u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631 \u0641\u064a \u0627\u0644\u0631\u0628\u064a\u0639 - \u0636\u0645\u0646 \u0627\u0644\u062d\u062f \u0627\u0644\u0645\u0633\u0645\u0648\u062d \u0628\u0647 \u0645\u0646 \u0642\u0628\u0644 \u0627\u0644\u0645\u0631\u0641\u0642 \u0648\u0647\u0648 35 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646. \u0641\u064a \u0630\u0644\u0643 \u0627\u0644\u062e\u0631\u064a\u0641\u060c \u0623\u062f\u0649 \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0645\u0645\u062a\u062f \u0628\u0639\u062f \u0627\u0644\u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u0637\u0648\u064a\u0644 \u0625\u0644\u0649 \u062a\u0639\u0637\u0644 \u0627\u0644\u0644\u0641. \u0648\u0643\u0634\u0641 \u062a\u062d\u0644\u064a\u0644 \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u0648\u0641\u0627\u0629:<\/p>\n<ul>\n<li>\u062a\u0645 \u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0632\u064a\u062a 45 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 (\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u062d\u0645\u0644)<\/li>\n<li>\u0643\u0627\u0646 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a 38% - \u0641\u064a \u0645\u0646\u0637\u0642\u0629 \u0627\u0644\u062d\u0630\u0631<\/li>\n<li>\u0628\u0644\u063a\u062a \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 3.81 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 30 \u0639\u0627\u0645\u064b\u0627 \u0645\u0646 \u0627\u0644\u062e\u062f\u0645\u0629<\/li>\n<li>\u0623\u062f\u0649 \u0628\u062f\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0639\u0644\u0649 \u0627\u0644\u0628\u0627\u0631\u062f \u0625\u0644\u0649 \u0627\u0646\u062e\u0641\u0627\u0636 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0632\u064a\u062a \u0625\u0644\u0649 5 \u062f\u0631\u062c\u0627\u062a \u0645\u0626\u0648\u064a\u0629\u060c \u0645\u062a\u062c\u0627\u0648\u0632\u0627\u064b \u0628\u0630\u0644\u0643 \u0642\u062f\u0631\u0629 \u0627\u0644\u062a\u0634\u0628\u0639<\/li>\n<\/ul>\n<p>\u0623\u0634\u0627\u0631\u062a \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0625\u0644\u0649 \u062c\u0632\u0621 \u0645\u0646 \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0627\u0644\u0645\u0637\u0644\u0642 \u0641\u0642\u0637 \u062f\u0648\u0646 \u0633\u064a\u0627\u0642 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0645\u0645\u0627 \u0623\u062f\u0649 \u0625\u0644\u0649 \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u062d\u0642\u064a\u0642\u064a\u0629.<\/p>\n<h3>\u062f\u0631\u0627\u0633\u0629 \u062d\u0627\u0644\u0629: \u062a\u0645\u062f\u064a\u062f \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0627\u0644\u0646\u0627\u062c\u062d<\/h3>\n<p>\u0623\u0638\u0647\u0631 \u0645\u062d\u0648\u0644 10 \u0645\u064a\u062c\u0627 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631 \u0639\u062a\u064a\u0642 \u0645\u0646 \u0639\u0627\u0645 1985 \u0641\u064a \u0645\u0646\u0634\u0623\u0629 \u062a\u0635\u0646\u064a\u0639 \u0631\u0637\u0648\u0628\u0629 \u062a\u0628\u0644\u063a 52 \u062c\u0632\u0621\u064b\u0627 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0639 \u0631\u0637\u0648\u0628\u0629 \u0648\u0631\u0642 \u062a\u0642\u062f\u0631 \u0628 3.21 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a. \u0648\u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0641\u0648\u0631\u064a\u060c \u0627\u062e\u062a\u0627\u0631\u062a \u0627\u0644\u0645\u0646\u0634\u0623\u0629:<\/p>\n<ol>\n<li>\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0627\u062e\u0646 \u0644\u0645\u062f\u0629 \u062b\u0644\u0627\u062b\u0629 \u0623\u0633\u0627\u0628\u064a\u0639 (\u062a\u062d\u0642\u064a\u0642 12 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0646 \u0627\u0644\u0632\u064a\u062a)<\/li>\n<li>\u0627\u0644\u062d\u0642\u0646 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 \u0628\u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u062c\u0627\u0641 (\u0623\u0631\u0628\u0639\u0629 \u0623\u0634\u0647\u0631)<\/li>\n<li>\u062d\u0634\u0648\u0627\u062a \u062c\u062f\u064a\u062f\u0629 \u0645\u0646 \u0645\u0637\u0627\u0637 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0648\u0646 \u0641\u064a \u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u0646\u062d\u0627\u0621<\/li>\n<li>\u062a\u0631\u0643\u064a\u0628 \u0645\u0633\u062a\u0634\u0639\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a<\/li>\n<\/ol>\n<p>\u0642\u062f\u0651\u0631 \u062a\u062d\u0644\u064a\u0644 DFR \u0644\u0644\u0645\u062a\u0627\u0628\u0639\u0629 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u0628\u0640 2.11 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a 3 \u062a\u064a\u0631\u0627\u0628\u0627\u064a\u062a. \u0639\u0627\u062f \u0627\u0644\u0645\u062d\u0648\u0644 \u0625\u0644\u0649 \u0627\u0644\u062e\u062f\u0645\u0629 \u0628\u0639\u0645\u0631 \u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0645\u0646\u0642\u062d \u0645\u062f\u062a\u0647 10 \u0633\u0646\u0648\u0627\u062a \u0645\u062a\u0628\u0642\u064a\u0629 \u0645\u0646 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0628\u062c\u0632\u0621 \u0628\u0633\u064a\u0637 \u0645\u0646 \u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644.<\/p>\n<hr \/>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629<\/h2>\n<h3>\u0645\u0627 \u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0630\u064a \u064a\u062a\u0637\u0644\u0628 \u0627\u062a\u062e\u0627\u0630 \u0625\u062c\u0631\u0627\u0621 \u0641\u0648\u0631\u064a\u061f<\/h3>\n<p>\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0632\u064a\u0648\u062a \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629\u060c \u0641\u0625\u0646 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u062c\u0627\u0648\u0632 35 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 (\u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0645\u0631\u062c\u0639\u064a\u0629 25 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629) \u0623\u0648 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0641\u0648\u0642 40% \u0639\u0646\u062f \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u062a\u062a\u0637\u0644\u0628 \u0641\u062d\u0635\u064b\u0627 \u0641\u0648\u0631\u064a\u064b\u0627. \u062a\u0634\u064a\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0632\u064a\u062f \u0639\u0646 3.5% \u0625\u0644\u0649 \u062a\u0633\u0627\u0631\u0639 \u0627\u0644\u0634\u064a\u062e\u0648\u062e\u0629 \u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u062a\u062e\u0637\u064a\u0637\u064b\u0627 \u0644\u0644\u062c\u0641\u0627\u0641 \u0641\u064a \u063a\u0636\u0648\u0646 6-12 \u0634\u0647\u0631\u064b\u0627. \u064a\u0634\u0643\u0644 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0641\u0648\u0642 50% \u0623\u0648 \u0627\u0644\u0645\u0627\u0621 \u0627\u0644\u062d\u0631 \u0627\u0644\u0645\u0631\u0626\u064a \u0641\u0648\u0642 50% \u062d\u0627\u0644\u0629 \u0637\u0627\u0631\u0626\u0629 - \u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u062d\u0645\u0644 \u0623\u0648 \u0625\u0644\u063a\u0627\u0621 \u062a\u0646\u0634\u064a\u0637\u0647 \u062d\u062a\u0649 \u062a\u062a\u0645 \u0645\u0639\u0627\u0644\u062c\u062a\u0647.<\/p>\n<h3>\u0643\u0645 \u0645\u0631\u0629 \u064a\u062c\u0628 \u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629\u061f<\/h3>\n<p>\u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062d\u0631\u062c\u0629 (\u062a\u063a\u0630\u064a\u0629 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a\u060c \u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u0629) \u062a\u0628\u0631\u0631 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a. \u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0644\u0642\u0649 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0623\u062e\u0631\u0649 \u0623\u062e\u0630 \u0639\u064a\u0646\u0627\u062a \u0632\u064a\u062a \u0633\u0646\u0648\u064a\u0629 \u0643\u062d\u062f \u0623\u062f\u0646\u0649\u060c \u0645\u0639 \u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u064a \u063a\u0636\u0648\u0646 30 \u064a\u0648\u0645\u064b\u0627 \u0645\u0646 \u0623\u064a \u0645\u0639\u0627\u0644\u062c\u0629 \u0644\u0644\u0632\u064a\u062a \u0623\u0648 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u062d\u0634\u064a\u0629 \u0623\u0648 \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u062f\u0627\u062e\u0644\u064a. \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u062f\u064a\u062f\u0629 \u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u062a\u062d\u0642\u0642 \u0642\u0628\u0644 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0645\u0631\u0629 \u0623\u062e\u0631\u0649 \u0628\u0639\u062f 6 \u0623\u0634\u0647\u0631 \u0644\u062a\u062d\u062f\u064a\u062f \u062e\u0637 \u0627\u0644\u0623\u0633\u0627\u0633.<\/p>\n<h3>\u0647\u0644 \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u0624\u062f\u064a \u0627\u0644\u062c\u0641\u0627\u0641 \u0625\u0644\u0649 \u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0645\u062a\u062f\u0647\u0648\u0631\u0629 \u0628\u0634\u062f\u0629\u061f<\/h3>\n<p>\u064a\u0639\u0645\u0644 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0639\u0644\u0649 \u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0644\u0643\u0646 \u0644\u0627 \u064a\u0645\u0643\u0646\u0647 \u0639\u0643\u0633 \u062a\u062f\u0647\u0648\u0631 \u0627\u0644\u0633\u0644\u064a\u0644\u0648\u0632 \u0627\u0644\u0630\u064a \u062d\u062f\u062b \u0628\u0627\u0644\u0641\u0639\u0644. \u0625\u0630\u0627 \u0641\u0642\u062f \u0627\u0644\u0648\u0631\u0642 \u0642\u0648\u062a\u0647 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0628\u0633\u0628\u0628 \u0633\u0646\u0648\u0627\u062a \u0645\u0646 \u0627\u0644\u062a\u0642\u0627\u062f\u0645 \u0627\u0644\u0645\u062a\u0633\u0627\u0631\u0639\u060c \u0641\u0625\u0646 \u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u062a\u0639\u0645\u0644 \u0639\u0644\u0649 \u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0645\u0627 \u062a\u0628\u0642\u0649 \u0645\u0646 \u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0648\u0644\u0643\u0646\u0647\u0627 \u0644\u0627 \u062a\u0639\u064a\u062f \u0628\u0646\u0627\u0621 \u0645\u0627 \u062a\u0645 \u0641\u0642\u062f\u0647. \u064a\u0633\u0627\u0639\u062f \u0627\u062e\u062a\u0628\u0627\u0631 \u062f\u0631\u062c\u0629 \u0627\u0644\u0628\u0644\u0645\u0631\u0629 (DP) \u0639\u0646 \u0637\u0631\u064a\u0642 \u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u0641\u0648\u0631\u0627\u0646 \u0641\u064a \u062a\u0642\u064a\u064a\u0645 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0645\u0641\u064a\u062f\u064b\u0627 \u0623\u0645 \u0623\u0646 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0623\u0643\u062b\u0631 \u062c\u062f\u0648\u0649 \u0645\u0646 \u0627\u0644\u0646\u0627\u062d\u064a\u0629 \u0627\u0644\u0627\u0642\u062a\u0635\u0627\u062f\u064a\u0629.<\/p>\n<h3>\u0645\u0627 \u0627\u0644\u0639\u0644\u0627\u0642\u0629 \u0628\u064a\u0646 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u062a\u062d\u0644\u064a\u0644 \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u0630\u0627\u0626\u0628\u0629\u061f<\/h3>\n<p>\u062a\u0639\u0645\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0639\u0644\u0649 \u062a\u0633\u0631\u064a\u0639 \u062a\u0642\u0627\u062f\u0645 \u0627\u0644\u0648\u0631\u0642 \u0648\u0625\u0646\u062a\u0627\u062c \u062b\u0627\u0646\u064a \u0623\u0643\u0633\u064a\u062f \u0627\u0644\u0643\u0631\u0628\u0648\u0646 \u0648\u0623\u0648\u0644 \u0623\u0643\u0633\u064a\u062f \u0627\u0644\u0643\u0631\u0628\u0648\u0646. \u062a\u062a\u064a\u062d \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0623\u064a\u0636\u064b\u0627 \u0646\u0634\u0627\u0637 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a \u0639\u0646\u062f \u0636\u063a\u0637 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u060c \u0645\u0645\u0627 \u064a\u0648\u0644\u062f \u0627\u0644\u0647\u064a\u062f\u0631\u0648\u062c\u064a\u0646 \u0648\u0623\u062d\u064a\u0627\u0646\u064b\u0627 \u0627\u0644\u0623\u0633\u064a\u062a\u064a\u0644\u064a\u0646. \u0648\u063a\u0627\u0644\u0628\u064b\u0627 \u0645\u0627 \u062a\u0643\u0634\u0641 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u062a\u062c\u0627\u0647\u0627\u062a \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u0630\u0627\u0626\u0628\u0629 \u062c\u0646\u0628\u064b\u0627 \u0625\u0644\u0649 \u062c\u0646\u0628 \u0645\u0639 \u062a\u0627\u0631\u064a\u062e \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0646 \u0639\u0644\u0627\u0642\u0627\u062a \u0627\u0644\u0633\u0628\u0628 \u0648\u0627\u0644\u0646\u062a\u064a\u062c\u0629 \u0627\u0644\u062a\u064a \u062a\u0641\u0633\u0631 \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u063a\u0627\u0645\u0636\u0629.<\/p>\n<h3>\u0647\u0644 \u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0625\u0633\u062a\u0631\u0627\u062a \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0631\u0637\u0648\u0628\u0629 \u0645\u062e\u062a\u0644\u0641\u0629\u061f<\/h3>\n<p>\u0628\u0627\u0644\u062a\u0623\u0643\u064a\u062f. \u0648\u062a\u062a\u062d\u0645\u0644 \u0627\u0644\u0625\u0633\u062a\u0631\u0627\u062a \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0631\u0637\u0648\u0628\u0629 \u0645\u0637\u0644\u0642\u0629 \u0623\u0639\u0644\u0649 \u0628\u0643\u062b\u064a\u0631 (200-400 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0646\u0645\u0648\u0630\u062c\u064a\u0629 \u0641\u064a \u0627\u0644\u062e\u062f\u0645\u0629) \u0628\u0633\u0628\u0628 \u0642\u062f\u0631\u062a\u0647\u0627 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u0634\u0628\u0639. \u0648\u0645\u0639 \u0630\u0644\u0643\u060c \u0641\u0625\u0646 \u062a\u0648\u0627\u0632\u0646 \u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0648\u0631\u0642 \u064a\u062e\u062a\u0644\u0641 - \u0641\u0627\u0644\u0625\u0633\u062a\u0631\u0627\u062a \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u062a\u0633\u062d\u0628 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0645\u0646 \u0627\u0644\u0648\u0631\u0642 \u0628\u0634\u0643\u0644 \u0623\u0643\u062b\u0631 \u0641\u0639\u0627\u0644\u064a\u0629\u060c \u0645\u0645\u0627 \u0642\u062f \u064a\u062d\u0633\u0646 \u0645\u0646 \u0637\u0648\u0644 \u0639\u0645\u0631 \u0627\u0644\u0648\u0631\u0642 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062a\u062d\u062f\u064a\u062b\u064a. \u062d\u062f\u062f \u062d\u062f\u0648\u062f \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a (&lt; 25% RS) \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0627\u0644\u0645\u0637\u0644\u0642 \u0644\u0644\u0633\u0648\u0627\u0626\u0644 \u0627\u0644\u0628\u062f\u064a\u0644\u0629.<\/p>\n<h3>\u0645\u0627 \u0645\u062f\u0649 \u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0623\u062c\u0647\u0632\u0629 \u0627\u0633\u062a\u0634\u0639\u0627\u0631 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a\u061f<\/h3>\n<p>\u062a\u0648\u0641\u0631 \u0627\u0644\u062d\u0633\u0627\u0633\u0627\u062a \u0627\u0644\u0633\u0639\u0648\u064a\u0629 \u0627\u0644\u062d\u062f\u064a\u062b\u0629 \u0642\u064a\u0627\u0633 \u062a\u0634\u0628\u0639 \u0646\u0633\u0628\u064a \u0645\u0648\u062b\u0648\u0642 \u0628\u0647 \u0639\u0646\u062f \u062a\u0631\u0643\u064a\u0628\u0647\u0627 \u0648\u0635\u064a\u0627\u0646\u062a\u0647\u0627 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d. \u0627\u0644\u062a\u062d\u0642\u0642 \u0627\u0644\u0633\u0646\u0648\u064a \u0645\u0646 \u0646\u062a\u0627\u0626\u062c \u0643\u0627\u0631\u0644 \u0641\u064a\u0634\u0631 \u0627\u0644\u0645\u062e\u062a\u0628\u0631\u064a\u0629 \u064a\u0624\u0643\u062f \u0627\u0644\u0645\u0639\u0627\u064a\u0631\u0629. \u0645\u0648\u0642\u0639 \u0627\u0644\u0645\u0633\u062a\u0634\u0639\u0631 \u0645\u0647\u0645 - \u064a\u062a\u0645 \u062a\u0631\u0643\u064a\u0628\u0647 \u0641\u064a \u0645\u0633\u0627\u0631 \u062f\u0648\u0631\u0627\u0646 \u0632\u064a\u062a \u0627\u0644\u062e\u0632\u0627\u0646 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u060c \u0648\u0644\u064a\u0633 \u0641\u064a \u0627\u0644\u062c\u064a\u0648\u0628 \u0627\u0644\u0631\u0627\u0643\u062f\u0629. \u062a\u0648\u0642\u0639 \u0639\u0645\u0631 \u0627\u0641\u062a\u0631\u0627\u0636\u064a \u0644\u0644\u0645\u0633\u062a\u0634\u0639\u0631 \u064a\u062a\u0631\u0627\u0648\u062d \u0628\u064a\u0646 5 \u06487 \u0633\u0646\u0648\u0627\u062a \u0642\u0628\u0644 \u0623\u0646 \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0627\u0646\u062c\u0631\u0627\u0641 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644.<\/p>\n<h3>\u0645\u0627 \u0647\u064a \u0627\u0644\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0623\u0646 \u062a\u0635\u0627\u062d\u0628 \u062e\u062f\u0645\u0627\u062a \u0627\u0644\u062a\u062c\u0641\u064a\u0641\u061f<\/h3>\n<p>\u062a\u062a\u0637\u0644\u0628: \u0642\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0623\u0648\u0644\u064a\u0629 (\u062c\u0632\u0621 \u0645\u0646 \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0645\u0646 \u0627\u0644\u0632\u064a\u062a\u060c \u0648\u0631\u0642\u0629 \u062a\u0642\u062f\u064a\u0631\u064a\u0629 %)\u060c \u0648\u0633\u062c\u0644 \u0645\u0639\u0644\u0645\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0629 (\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u0648\u0627\u0644\u0645\u062f\u0629)\u060c \u0648\u0642\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0645\u0639 \u0641\u062a\u0631\u0629 \u062a\u062b\u0628\u064a\u062a \u0644\u0645\u062f\u0629 48 \u0633\u0627\u0639\u0629\u060c \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u062c\u0648\u062f\u0629 \u0627\u0644\u0632\u064a\u062a (\u0642\u0648\u0629 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0627\u0644\u062d\u0645\u0648\u0636\u0629\u060c \u0648\u0627\u0644\u062a\u0648\u062a\u0631 \u0627\u0644\u0628\u064a\u0646\u064a)\u060c \u0648\u0634\u0647\u0627\u062f\u0629 \u0628\u0623\u0646 \u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0633\u062a\u062e\u062f\u0645\u062a \u0632\u064a\u062a\u064b\u0627 \u0646\u0638\u064a\u0641\u064b\u0627 \u064a\u0641\u064a \u0628\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0623\u0648 \u064a\u062a\u062c\u0627\u0648\u0632\u0647\u0627.<\/p>\n<hr \/>\n<h2>\u0627\u0644\u062e\u0627\u062a\u0645\u0629: \u0627\u0644\u0648\u062c\u0628\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<p>\u062a\u062a\u0637\u0644\u0628 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0641\u064a \u0639\u0632\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0641\u0647\u0645 \u0643\u0644 \u0645\u0646 \u0627\u0644\u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0645\u0637\u0644\u0642 (\u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646) \u0648\u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0648\u0638\u064a\u0641\u064a\u0629 (\u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a). \u0644\u0627 \u064a\u062d\u0643\u064a \u0623\u064a \u0645\u0646 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0646 \u0648\u062d\u062f\u0647 \u0627\u0644\u0642\u0635\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 - \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u062a\u0641\u0633\u064a\u0631 \u0627\u0644\u0633\u0644\u064a\u0645 \u0633\u064a\u0627\u0642 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0648\u0639\u064a \u0628\u0627\u0644\u062a\u0648\u0627\u0632\u0646 \u0648\u0627\u0644\u0627\u0631\u062a\u0628\u0627\u0637 \u0628\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062a\u0634\u062e\u064a\u0635 \u0627\u0644\u0623\u062e\u0631\u0649.<\/p>\n<p>\u0627\u0644\u0645\u0628\u0627\u062f\u0626 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u062a\u0630\u0643\u0631\u0647\u0627<\/p>\n<ol>\n<li><strong>\u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a \u0645\u0647\u0645 \u0623\u0643\u062b\u0631 \u0645\u0646 \u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0645\u0637\u0644\u0642 \u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646<\/strong> \u0644\u062a\u0642\u064a\u064a\u0645 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0639\u0632\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/li>\n<li><strong>\u064a\u062d\u062a\u0648\u064a \u0627\u0644\u0648\u0631\u0642 \u0639\u0644\u0649 \u0631\u0637\u0648\u0628\u0629 \u0623\u0643\u062b\u0631 \u0628\u0645\u0642\u062f\u0627\u0631 1,000 \u0625\u0644\u0649 3,000 \u0636\u0639\u0641 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/strong> \u0645\u0646 \u0627\u0644\u0646\u0641\u0637 \u0627\u0644\u0645\u062d\u064a\u0637 \u0628\u0647\u0627-\u062f\u0627\u0626\u0645\u0627\u064b \u0645\u0627 \u062a\u0642\u062f\u0631 \u062d\u0627\u0644\u0629 \u0627\u0644\u0648\u0631\u0642<\/li>\n<li><strong>\u062a\u0624\u062b\u0631 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0628\u0634\u0643\u0644 \u0643\u0628\u064a\u0631 \u0639\u0644\u0649 \u0627\u0644\u0627\u062a\u0632\u0627\u0646<\/strong>-\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u064a \u0638\u0631\u0648\u0641 \u062b\u0627\u0628\u062a\u0629 \u0648\u0645\u0648\u062b\u0642\u0629<\/li>\n<li><strong>\u062a\u062a\u0637\u0644\u0628 \u0627\u0644\u0633\u0648\u0627\u0626\u0644 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u062d\u062f\u0648\u062f\u0627\u064b \u0645\u062e\u062a\u0644\u0641\u0629<\/strong>-\u0627\u0644\u0625\u0633\u062a\u0631\u0627\u062a \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u062a\u062a\u062d\u0645\u0644 \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0645\u0637\u0644\u0642\u0629 \u0627\u0644\u0623\u0639\u0644\u0649 \u0628\u0623\u0645\u0627\u0646<\/li>\n<li><strong>\u064a\u0639\u062a\u0645\u062f \u0627\u062e\u062a\u064a\u0627\u0631 \u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0639\u0644\u0649 \u0627\u0644\u0634\u062f\u0629<\/strong>-\u062a\u062f\u0648\u064a\u0631 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0633\u0627\u062e\u0646 \u0644\u0644\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u062e\u0641\u064a\u0641\u0629\u060c \u0648\u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0628\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0641\u064a \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u062a\u0644\u0648\u062b \u0627\u0644\u062e\u0637\u064a\u0631<\/li>\n<li><strong>\u064a\u062c\u0628 \u0623\u0646 \u062a\u0643\u0648\u0646 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0648\u0627\u0636\u062d\u0629<\/strong>-\u062a\u0634\u0645\u0644 \u0645\u0631\u0627\u062c\u0639 \u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629\u060c \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u062d\u0642\u0642\u060c \u0648\u0639\u0648\u0627\u0642\u0628 \u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644<\/li>\n<\/ol>\n<p>\u0644\u0644\u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0625\u0631\u0634\u0627\u062f\u0627\u062a \u0634\u0627\u0645\u0644\u0629 \u062d\u0648\u0644 \u0645\u0646\u0647\u062c\u064a\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0632\u0644 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u060c \u0631\u0627\u062c\u0639 IEEE C57.152-2013\u060c \u201c\u062f\u0644\u064a\u0644 IEEE \u0644\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0627\u0644\u062a\u0634\u062e\u064a\u0635\u064a \u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u0645\u0644\u0648\u0621\u0629 \u0628\u0627\u0644\u0633\u0648\u0627\u0626\u0644 \u0648\u0627\u0644\u0645\u0646\u0638\u0645\u064a\u0646 \u0648\u0627\u0644\u0645\u0641\u0627\u0639\u0644\u0627\u062a.\u201d<\/p>\n<p>\u062a\u0639\u0645\u0644 \u0627\u0644\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0633\u0644\u064a\u0645\u0629 \u0644\u0644\u0631\u0637\u0648\u0628\u0629 \u0639\u0644\u0649 \u0625\u0637\u0627\u0644\u0629 \u0639\u0645\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0644\u0639\u0642\u0648\u062f \u0645\u0646 \u0627\u0644\u0632\u0645\u0646 \u0648\u062a\u0645\u0646\u0639 \u062d\u062f\u0648\u062b \u0623\u0639\u0637\u0627\u0644 \u063a\u064a\u0631 \u0645\u062a\u0648\u0642\u0639\u0629 \u062a\u0642\u062f\u0631 \u0642\u064a\u0645\u062a\u0647\u0627 \u0628\u0627\u0644\u0645\u0644\u0627\u064a\u064a\u0646 \u0645\u0646 \u0627\u0644\u0623\u0636\u0631\u0627\u0631 \u0627\u0644\u0645\u0628\u0627\u0634\u0631\u0629 \u0648\u0627\u0644\u062e\u0633\u0627\u0626\u0631 \u0627\u0644\u062a\u0628\u0639\u064a\u0629. \u0627\u0644\u0627\u0633\u062a\u062b\u0645\u0627\u0631 \u0641\u064a \u0641\u0647\u0645 \u0647\u0630\u0647 \u0627\u0644\u0645\u0628\u0627\u062f\u0626 \u064a\u0624\u062a\u064a \u062b\u0645\u0627\u0631\u0647 \u0637\u0648\u0627\u0644 \u062d\u064a\u0627\u062a\u0643 \u0627\u0644\u0645\u0647\u0646\u064a\u0629 \u0641\u064a \u0635\u064a\u0627\u0646\u0629 \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0637\u0627\u0642\u0629.<\/p>\n<h2>\u0627\u0644\u0645\u0648\u0627\u0631\u062f \u0627\u0644\u062a\u0642\u0646\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629<\/h2>\n<ul>\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/C57.152\/\" target=\"_blank\" rel=\"noopener\">\u062f\u0644\u064a\u0644 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0627\u0644\u062a\u0634\u062e\u064a\u0635\u064a \u0644\u0645\u062d\u0648\u0644 IEEE C57.152 IEEE C57.152<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/transformer-oil-technical-guide\/\">\u0627\u0644\u062f\u0644\u064a\u0644 \u0627\u0644\u0641\u0646\u064a \u0644\u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/distribution-transformer-guide\/\">\u062f\u0644\u064a\u0644 \u0645\u062d\u0648\u0644 \u0627\u0644\u062a\u0648\u0632\u064a\u0639<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/power-distribution-transformers\/\">\u062d\u0644\u0648\u0644 \u0645\u062d\u0648\u0644\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/transformer-losses-p0-pk-tco-comparison\/\">\u0645\u0642\u0627\u0631\u0646\u0629 \u062e\u0633\u0627\u0626\u0631 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0644\u0644\u0645\u0644\u0643\u064a\u0629<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ar\/sfra-transformer-testing-guide\/\">\u062f\u0644\u064a\u0644 SFRA \u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0645\u062d\u0648\u0644\u0627\u062a SFRA<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u0641\u0647\u0645 \u0631\u0637\u0648\u0628\u0629 \u0632\u064a\u062a \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0627\u0644\u062c\u0632\u0621 \u0641\u064a \u0627\u0644\u0645\u0644\u064a\u0648\u0646 \u0648\u0627\u0644\u062a\u0634\u0628\u0639 \u0627\u0644\u0646\u0633\u0628\u064a\u060c \u0645\u0639 \u0637\u0631\u0642 \u0627\u0644\u062c\u0641\u0627\u0641 \u0648\u0639\u062a\u0628\u0627\u062a\u0647 \u0648\u0646\u0635\u0627\u0626\u062d \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a.<\/p>","protected":false},"author":3,"featured_media":3704,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-3709","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/3709","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=3709"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/3709\/revisions"}],"predecessor-version":[{"id":3777,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/3709\/revisions\/3777"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/3704"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=3709"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=3709"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=3709"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}