{"id":4168,"date":"2026-08-07T09:00:00","date_gmt":"2026-08-07T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=4168"},"modified":"2026-08-18T14:59:03","modified_gmt":"2026-08-18T14:59:03","slug":"vcb-reclose-logic-in-motor-feeders-when-to-disable-auto-reclose","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/vcb-reclose-logic-in-motor-feeders-when-to-disable-auto-reclose\/","title":{"rendered":"\u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB \u0641\u064a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a: \u0645\u062a\u0649 \u064a\u062c\u0628 \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a"},"content":{"rendered":"<h2>\u062e\u0644\u0627\u0635\u0629 \u0633\u0631\u064a\u0639\u0629<\/h2>\n<ul>\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0648\u0638\u0631\u0648\u0641 \u062a\u0634\u063a\u064a\u0644 VCB \u0642\u0628\u0644 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0623\u0648 \u0625\u062c\u0631\u0627\u0621 \u0623\u0639\u0645\u0627\u0644 \u0627\u0644\u062e\u062f\u0645\u0629.<\/li>\n<li>\u0627\u0633\u062a\u0646\u062f \u0625\u0644\u0649 \u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0641\u062d\u0635 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062f\u0639\u0648\u0645\u0629.<\/li>\n<li>\u0627\u062d\u062a\u0641\u0638 \u0628\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u0642\u0628\u0648\u0644 \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0644\u062a\u0633\u0644\u064a\u0645 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0636\u0645\u0646 \u0633\u062c\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a.<\/li>\n<\/ul>\n<p>\u0648\u0641\u0631\u062a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0633\u0627\u0639\u0627\u062a \u0644\u0627 \u062a\u062d\u0635\u0649 \u0645\u0646 \u0627\u0646\u0642\u0637\u0627\u0639 \u0627\u0644\u062a\u063a\u0630\u064a\u0629 \u063a\u064a\u0631 \u0627\u0644\u0636\u0631\u0648\u0631\u064a \u0639\u0644\u0649 \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639. \u064a\u0632\u0648\u0644 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0639\u0627\u0628\u0631\u060c \u062b\u0645 \u064a\u063a\u0644\u0642 \u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u062c\u062f\u062f\u0627\u064b \u0648\u064a\u0633\u062a\u0639\u064a\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0639\u0645\u0644\u0647 \u0645\u0646 \u062f\u0648\u0646 \u062a\u062f\u062e\u0644 \u064a\u062f\u0648\u064a. \u062a\u0646\u062c\u062d \u0647\u0630\u0647 \u0627\u0644\u0645\u0646\u0638\u0648\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u062e\u0637\u0648\u0637 \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629 \u062d\u064a\u062b \u062a\u0643\u0648\u0646 \u0645\u0639\u0638\u0645 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0645\u0624\u0642\u062a\u0629\u060c \u0644\u0643\u0646\u0647\u0627 \u0623\u0642\u0644 \u0645\u0644\u0627\u0621\u0645\u0629 \u0628\u0643\u062b\u064a\u0631 \u0639\u0646\u062f\u0645\u0627 \u064a\u0643\u0648\u0646 \u0627\u0644\u062d\u0645\u0644 \u0641\u064a \u0627\u0644\u0637\u0631\u0641 \u0627\u0644\u0622\u062e\u0631 \u0645\u0646 \u0627\u0644\u0643\u0627\u0628\u0644 \u0645\u062d\u0631\u0643\u0627\u064b \u062d\u062b\u064a\u0627\u064b \u0628\u0642\u062f\u0631\u0629 500 kW \u064a\u0648\u0627\u0635\u0644 \u0627\u0644\u062f\u0648\u0631\u0627\u0646 \u0628\u0639\u062f \u0641\u0635\u0644 \u0627\u0644\u0642\u0627\u0637\u0639\u060c \u062b\u0645 \u062a\u062a\u0645 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0639\u0646\u062f \u0632\u0627\u0648\u064a\u0629 \u0637\u0648\u0631 \u062a\u0628\u0644\u063a 150\u00b0 \u0628\u064a\u0646 \u0627\u0644\u062e\u0637 \u0648\u0627\u0644\u0645\u062d\u0631\u0643 \u062e\u0644\u0627\u0644 \u0627\u0636\u0645\u062d\u0644\u0627\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a. \u0648\u0642\u062f \u062a\u0646\u062a\u062c \u0639\u0646 \u0630\u0644\u0643 \u0642\u0641\u0632\u0629 \u0641\u064a \u0627\u0644\u0639\u0632\u0645 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u062a\u0643\u0641\u064a \u0644\u0642\u0635 \u0648\u0635\u0644\u0629 \u0627\u0644\u0639\u0645\u0648\u062f \u0623\u0648 \u0625\u062a\u0644\u0627\u0641 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643 \u0642\u0628\u0644 \u0623\u0646 \u062a\u062a\u0645\u0643\u0646 \u0623\u064a \u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629.<\/p>\n<p>\u0644\u0630\u0644\u0643 \u0641\u0625\u0646 \u0641\u0647\u0645 \u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0644\u064a\u0633 \u062a\u0645\u0631\u064a\u0646\u0627\u064b \u0646\u0638\u0631\u064a\u0627\u064b\u060c \u0628\u0644 \u0642\u0631\u0627\u0631 \u0647\u0646\u062f\u0633\u064a \u0639\u0645\u0644\u064a \u064a\u0624\u062b\u0631 \u0641\u0639\u0644\u064a\u0627\u064b \u0641\u064a \u0639\u0645\u0631 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0639\u0627\u0645\u0644\u064a\u0646 \u0648\u0645\u0648\u062b\u0648\u0642\u064a\u0629 \u0627\u0644\u0646\u0638\u0627\u0645. \u064a\u0633\u062a\u0639\u0631\u0636 \u0647\u0630\u0627 \u0627\u0644\u0645\u0642\u0627\u0644 \u0645\u0628\u0627\u062f\u0626 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a\u060c \u0648\u064a\u0648\u0636\u062d \u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u062e\u0627\u0635\u0629 \u0627\u0644\u062a\u064a \u062a\u0646\u0634\u0623 \u0645\u0639 \u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a\u060c \u0648\u064a\u062d\u062f\u062f \u0627\u0644\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0641\u064a\u0647\u0627 \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0623\u0648 \u062d\u0638\u0631\u0647\u0627\u060c \u0643\u0645\u0627 \u064a\u0642\u062f\u0645 \u0625\u0637\u0627\u0631\u0627\u064b \u0645\u0646\u0638\u0645\u0627\u064b \u0644\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0648\u0627\u0644\u0641\u0646\u064a\u064a\u0646 \u0644\u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631 \u0627\u0644\u0635\u062d\u064a\u062d.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-reclose-logic-in-motor-feeders-when-to-disable-auto-reclose-fig-01.webp\" alt=\"\u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB \u0641\u064a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0645\u0646 XBRELE: \u0645\u062a\u0649 \u064a\u062c\u0628 \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a - \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u0647\u0646\u062f\u0633\u064a\u0629\" \/><\/figure>\n<h3>\u0633\u0628\u0628 \u0648\u062c\u0648\u062f \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0648\u0627\u0644\u063a\u0631\u0636 \u0627\u0644\u0630\u064a \u0635\u0645\u0645\u062a \u0645\u0646 \u0623\u062c\u0644\u0647<\/h3>\n<p>\u0638\u0647\u0631\u062a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0645\u0634\u0643\u0644\u0629 \u0645\u062d\u062f\u062f\u0629: \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u0624\u0642\u062a\u0629 \u0639\u0644\u0649 \u062e\u0637\u0648\u0637 \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629. \u0648\u062a\u062a\u0633\u0628\u0628 \u0627\u0644\u0635\u0648\u0627\u0639\u0642 \u0648\u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062d\u0631\u0643\u0647\u0627 \u0627\u0644\u0631\u064a\u0627\u062d \u0648\u0645\u0644\u0627\u0645\u0633\u0629 \u0627\u0644\u0637\u064a\u0648\u0631 \u0648\u0633\u0642\u0648\u0637 \u0627\u0644\u0623\u063a\u0635\u0627\u0646 \u0641\u064a \u0645\u0639\u0638\u0645 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u060c \u0648\u064a\u0632\u0648\u0644 \u062c\u0632\u0621 \u0643\u0628\u064a\u0631 \u0645\u0646\u0647\u0627 \u0630\u0627\u062a\u064a\u0627\u064b \u0628\u0639\u062f \u0627\u0646\u0637\u0641\u0627\u0621 \u0627\u0644\u0642\u0648\u0633. \u0648\u062a\u0628\u064a\u0646 \u062f\u0631\u0627\u0633\u0627\u062a \u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0628\u0627\u0633\u062a\u0645\u0631\u0627\u0631 \u0623\u0646 \u0646\u0633\u0628\u0629 70 \u0625\u0644\u0649 85 \u0628\u0627\u0644\u0645\u0626\u0629 \u0645\u0646 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0637\u0648\u0637 \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629 \u0639\u0627\u0628\u0631\u0629. \u0648\u062a\u0633\u062a\u0641\u064a\u062f \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0645\u0646 \u0630\u0644\u0643 \u0628\u0625\u0635\u062f\u0627\u0631 \u0623\u0645\u0631 \u0625\u063a\u0644\u0627\u0642 \u0644\u0644\u0642\u0627\u0637\u0639 \u0628\u0639\u062f \u0632\u0645\u0646 \u0645\u064a\u062a\u060c \u064a\u062a\u0631\u0627\u0648\u062d \u0639\u0627\u062f\u0629 \u0628\u064a\u0646 0.3 \u062b\u0627\u0646\u064a\u0629 \u0648\u0628\u0636\u0639 \u062b\u0648\u0627\u0646\u064d \u0648\u0641\u0642 \u0641\u0644\u0633\u0641\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629.<\/p>\n<p>\u062a\u0639\u0645\u0644 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0639\u0628\u0631 \u0645\u0631\u0627\u0642\u0628\u0629 \u0645\u062e\u0627\u0631\u062c \u0641\u0635\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629. \u0639\u0646\u062f\u0645\u0627 \u064a\u0639\u0645\u0644 \u0639\u0646\u0635\u0631 \u062d\u0645\u0627\u064a\u0629 \u0645\u0624\u0647\u0644 \u0648\u064a\u0641\u0635\u0644 \u0627\u0644\u0642\u0627\u0637\u0639\u060c \u064a\u0628\u062f\u0623 \u0639\u0646\u0635\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0645\u0624\u0642\u062a \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a. \u0648\u0639\u0646\u062f \u0627\u0646\u062a\u0647\u0627\u0621 \u0627\u0644\u0645\u0624\u0642\u062a\u060c \u064a\u062a\u0644\u0642\u0649 \u0627\u0644\u0642\u0627\u0637\u0639 \u0623\u0645\u0631 \u0625\u063a\u0644\u0627\u0642 \u0625\u0630\u0627 \u062a\u062d\u0642\u0642\u062a \u0634\u0631\u0648\u0637 \u0627\u0644\u062c\u0627\u0647\u0632\u064a\u0629 \u0627\u0644\u0645\u062d\u062f\u062f\u0629. \u0625\u0630\u0627 \u0632\u0627\u0644 \u0627\u0644\u0639\u0637\u0644\u060c \u064a\u0633\u062a\u0639\u064a\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0639\u0645\u0644\u0647 \u0628\u0635\u0648\u0631\u0629 \u0637\u0628\u064a\u0639\u064a\u0629. \u0648\u0625\u0630\u0627 \u0627\u0633\u062a\u0645\u0631 \u0627\u0644\u0639\u0637\u0644\u060c \u064a\u062d\u062f\u062b \u0641\u0635\u0644 \u062b\u0627\u0646\u064d\u060c \u062b\u0645 \u062a\u062d\u0627\u0648\u0644 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u062f\u0648\u0631\u0629 \u0623\u062e\u0631\u0649 \u0623\u0648 \u062a\u062f\u062e\u0644 \u0641\u064a \u062d\u0627\u0644\u0629 \u0642\u0641\u0644\u060c \u0648\u0641\u0642 \u0639\u062f\u062f \u0627\u0644\u0645\u062d\u0627\u0648\u0644\u0627\u062a \u0627\u0644\u0645\u0628\u0631\u0645\u062c.<\/p>\n<p>\u062a\u0648\u0636\u062d \u0648\u062b\u0627\u0626\u0642 ABB \u0623\u0646 \u0625\u0634\u0627\u0631\u0627\u062a \u0641\u0635\u0644 \u062d\u0645\u0627\u064a\u0629 \u0645\u062e\u062a\u0627\u0631\u0629 \u0623\u0648 \u0645\u062f\u062e\u0644\u0627\u064b \u0631\u0642\u0645\u064a\u0627\u064b \u064a\u0645\u0643\u0646\u0647\u0627 \u062d\u0638\u0631 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a\u060c \u0648\u0623\u0646 \u0645\u0648\u0636\u0639 \u0627\u0644\u0642\u0627\u0637\u0639 \u0648\u062d\u0627\u0644\u062a\u0647\u060c \u0625\u0644\u0649 \u062c\u0627\u0646\u0628 \u062c\u0627\u0647\u0632\u064a\u062a\u0647 \u0644\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0645\u062f\u062e\u0644\u0627\u062a \u0645\u0647\u0645\u0629 \u0641\u064a \u0627\u0644\u062a\u0633\u0644\u0633\u0644. \u0648\u0647\u0630\u0647 \u0627\u0644\u0628\u0646\u064a\u0629 \u0645\u0647\u0645\u0629: \u0622\u0644\u064a\u0629 \u0627\u0644\u062d\u0638\u0631 \u0645\u064a\u0632\u0629 \u0623\u0633\u0627\u0633\u064a\u0629 \u0641\u064a \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0648\u0644\u064a\u0633\u062a \u0625\u0636\u0627\u0641\u0629 \u0644\u0627\u062d\u0642\u0629. \u0641\u0642\u062f \u0623\u062e\u0630 \u0627\u0644\u0645\u0635\u0645\u0645\u0648\u0646 \u0641\u064a \u0627\u0644\u062d\u0633\u0628\u0627\u0646 \u0623\u0646 \u0628\u0639\u0636 \u062d\u0627\u0644\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0644\u0627 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0633\u0645\u062d \u0628\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642.<\/p>\n<h3>\u0643\u064a\u0641 \u062a\u0641\u0635\u0644 \u0623\u0648\u0636\u0627\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0631\u062d\u0644 \u0628\u064a\u0646 \u0645\u0646\u0637\u0642 \u0627\u0644\u0645\u063a\u0630\u064a \u0648\u0645\u0646\u0637\u0642 \u0627\u0644\u0645\u062d\u0631\u0643<\/h3>\n<p>\u062a\u0633\u062a\u062e\u062f\u0645 \u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0631\u0642\u0645\u064a\u0629 \u0627\u0644\u062d\u062f\u064a\u062b\u0629 \u0628\u0635\u0648\u0631\u0629 \u0645\u062a\u0632\u0627\u064a\u062f\u0629 \u0623\u0648\u0636\u0627\u0639 \u062a\u0637\u0628\u064a\u0642 \u0635\u0631\u064a\u062d\u0629 \u0644\u0641\u0631\u0636 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0645\u0644\u0627\u0626\u0645\u0629 \u0644\u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0623\u062d\u0645\u0627\u0644 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629. \u0648\u062a\u0645\u064a\u0632 Schneider Electric \u0628\u064a\u0646 \u0648\u0636\u0639\u064a \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u063a\u0630\u064a \u0648\u0627\u0644\u0645\u062d\u0631\u0643 \u0641\u064a \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0631\u062d\u0644\u0627\u062a\u0647\u0627: \u062a\u062a\u0648\u0641\u0631 \u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0645\u063a\u0630\u064a \u0645\u062b\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a\u060c \u0628\u064a\u0646\u0645\u0627 \u064a\u0648\u0641\u0631 \u0648\u0636\u0639 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0628\u062f\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0648\u062d\u0645\u0627\u064a\u0627\u062a \u0623\u062e\u0631\u0649 \u062e\u0627\u0635\u0629 \u0628\u0647. \u0644\u0630\u0627 \u064a\u062c\u0628 \u0627\u062e\u062a\u064a\u0627\u0631 \u0648\u0636\u0639 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0635\u062d\u064a\u062d \u0644\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0642\u0635\u0648\u062f. \u0625\u0646 <a href=\"https:\/\/www.se.com\/ng\/en\/faqs\/FA337526\/\" target=\"_blank\" rel=\"noopener\">\u0625\u0631\u0634\u0627\u062f\u0627\u062a Schneider Electric \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a<\/a> \u0628\u0648\u0635\u0641\u0647 \u0627\u0644\u0645\u0635\u062f\u0631 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u0644\u0644\u0645\u062a\u0637\u0644\u0628 \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0645\u0646\u062a\u062c \u0627\u0644\u0645\u0630\u0643\u0648\u0631 \u0647\u0646\u0627.<\/p>\n<p>\u064a\u0645\u062b\u0644 \u0630\u0644\u0643 \u062e\u064a\u0627\u0631\u0627\u064b \u062a\u0635\u0645\u064a\u0645\u064a\u0627\u064b \u0645\u0647\u0645\u0627\u064b. \u0641\u0645\u0635\u0646\u0639 \u0627\u0644\u0645\u0631\u062d\u0644 \u064a\u0631\u0633\u062e \u0639\u0645\u0644\u064a\u0627\u064b \u062d\u0643\u0645\u0627\u064b \u0647\u0646\u062f\u0633\u064a\u0627\u064b \u0645\u0641\u0627\u062f\u0647 \u0623\u0646 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0648\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0631\u0643 \u064a\u0646\u062a\u0645\u064a\u0627\u0646 \u0625\u0644\u0649 \u0646\u0637\u0627\u0642\u064a\u0646 \u0648\u0638\u064a\u0641\u064a\u064a\u0646 \u0645\u062e\u062a\u0644\u0641\u064a\u0646. \u0648\u064a\u062a\u0637\u0644\u0628 \u062a\u0645\u0643\u064a\u0646 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0641\u064a \u0648\u0636\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u062d\u0631\u0643 \u062a\u062c\u0627\u0648\u0632\u0627\u064b \u0645\u062a\u0639\u0645\u062f\u0627\u064b \u0644\u062d\u062f\u0648\u062f \u0627\u0644\u0648\u0636\u0639\u060c \u0645\u0627 \u064a\u062f\u0641\u0639 \u0627\u0644\u0645\u0647\u0646\u062f\u0633 \u0625\u0644\u0649 \u0627\u0644\u062a\u0641\u0643\u064a\u0631 \u0641\u064a \u0627\u0644\u0642\u0631\u0627\u0631 \u0628\u0648\u0639\u064a. \u0648\u0639\u0646\u062f \u0636\u0628\u0637 \u0627\u0644\u0645\u0631\u062d\u0644 \u0628\u0635\u0648\u0631\u0629 \u0635\u062d\u064a\u062d\u0629 \u0639\u0644\u0649 \u0648\u0636\u0639 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0644\u0627 \u064a\u0643\u0648\u0646 \u063a\u064a\u0627\u0628 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0633\u0647\u0648\u0627\u064b\u060c \u0628\u0644 \u064a\u0639\u0643\u0633 \u0647\u0646\u062f\u0633\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642.<\/p>\n<p>\u0648\u0627\u0644\u0646\u062a\u064a\u062c\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0644\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0627\u0644\u0630\u064a\u0646 \u064a\u0634\u063a\u0644\u0648\u0646 \u0644\u0648\u062d\u0627\u062a VCB \u0639\u0644\u0649 \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0647\u064a \u0623\u0646 \u062a\u0647\u064a\u0626\u0629 \u0627\u0644\u0645\u0631\u062d\u0644 \u062a\u0628\u062f\u0623 \u0628\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0648\u0636\u0639. \u0625\u0646 \u0627\u062e\u062a\u064a\u0627\u0631 \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a \u0644\u0645\u063a\u0630\u064d \u062e\u0627\u0635 \u0628\u0645\u062d\u0631\u0643 \u0644\u0645\u062c\u0631\u062f \u0625\u062a\u0627\u062d\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0647\u0648 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u062e\u0627\u0637\u0626 \u0644\u0644\u0645\u0631\u062d\u0644. \u0648\u0644\u0627 \u064a\u0645\u0643\u0646 \u062a\u062d\u0642\u064a\u0642 \u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0648\u0641\u0642 \u0645\u0639\u0627\u064a\u064a\u0631 \u0645\u062b\u0644 IEC\/EN 60947-4-1\u060c \u0627\u0644\u062a\u064a \u062a\u062d\u062f\u062f \u0625\u0631\u0634\u0627\u062f\u0627\u062a Schneider \u0644\u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0636\u0631\u0648\u0631\u0629 \u0627\u0644\u062a\u0646\u0633\u064a\u0642 \u0628\u064a\u0646 \u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0639\u0646\u062f\u0645\u0627 \u064a\u0639\u0645\u0644 \u0627\u0644\u0645\u0631\u062d\u0644 \u062e\u0627\u0631\u062c \u0627\u0644\u0648\u0636\u0639 \u0627\u0644\u0645\u062e\u0635\u0635 \u0644\u0647. \u0627\u0633\u062a\u062e\u062f\u0645 <a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker\/\">\u062e\u064a\u0627\u0631\u0627\u062a \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0645\u0641\u0631\u063a<\/a> \u0644\u0644\u0641\u0631\u0632 \u0627\u0644\u0623\u0648\u0644\u064a \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062a\u0627\u062d\u0629 \u0648\u0641\u0642 \u0638\u0631\u0648\u0641 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0642\u0628\u0644 \u0637\u0644\u0628 \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0646\u0647\u0627\u0626\u064a.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-reclose-logic-in-motor-feeders-when-to-disable-auto-reclose-fig-02.webp\" alt=\"\u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB \u0641\u064a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0645\u0646 XBRELE: \u0645\u062a\u0649 \u064a\u062c\u0628 \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a - \u0642\u064a\u0627\u0633 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\" \/><\/figure>\n<h3>\u0641\u064a\u0632\u064a\u0627\u0621 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0644\u0644\u0645\u062d\u0631\u0643 \u0648\u0623\u0647\u0645\u064a\u062a\u0647<\/h3>\n<p>\u0639\u0646\u062f\u0645\u0627 \u064a\u0641\u0642\u062f \u0645\u062d\u0631\u0643 \u062d\u062b\u064a \u064a\u0639\u0645\u0644 \u062a\u063a\u0630\u064a\u062a\u0647\u060c \u0644\u0627 \u064a\u062a\u0648\u0642\u0641 \u0641\u0648\u0631\u0627\u064b \u0639\u0646 \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u062c\u0647\u062f \u0639\u0646\u062f \u0623\u0637\u0631\u0627\u0641\u0647. \u064a\u062a\u0646\u0627\u0642\u0635 \u0627\u0644\u0641\u064a\u0636 \u0627\u0644\u062f\u0648\u0627\u0631 \u0623\u064f\u0633\u0651\u064a\u0627\u064b \u0628\u062b\u0627\u0628\u062a \u0632\u0645\u0646\u064a \u064a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u0622\u0644\u0629\u060c \u0648\u064a\u062a\u0631\u0627\u0648\u062d \u0639\u0627\u062f\u0629 \u0645\u0646 0.1 \u062b\u0627\u0646\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0635\u063a\u064a\u0631\u0629 \u0625\u0644\u0649 \u0623\u0643\u062b\u0631 \u0645\u0646 \u062b\u0627\u0646\u064a\u0629 \u0644\u0644\u0622\u0644\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0630\u0627\u062a \u0627\u0644\u0642\u0635\u0648\u0631 \u0627\u0644\u0630\u0627\u062a\u064a \u0627\u0644\u0645\u0631\u062a\u0641\u0639. \u0648\u062e\u0644\u0627\u0644 \u0641\u062a\u0631\u0629 \u0627\u0644\u062a\u0646\u0627\u0642\u0635 \u064a\u0639\u0645\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0643\u0645\u0648\u0644\u062f\u060c \u0645\u0646\u062a\u062c\u0627\u064b \u062c\u0647\u062f\u0627\u064b \u0637\u0631\u0641\u064a\u0627\u064b \u064a\u062a\u063a\u064a\u0631 \u0645\u0642\u062f\u0627\u0631\u0647 \u0648\u0632\u0627\u0648\u064a\u0629 \u0637\u0648\u0631\u0647 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0625\u0644\u0649 \u0645\u0635\u062f\u0631 \u0627\u0644\u062a\u063a\u0630\u064a\u0629.<\/p>\n<p>\u064a\u0646\u0634\u0623 \u0627\u0644\u062e\u0637\u0631 \u0639\u0646\u062f \u0639\u0648\u062f\u0629 \u0627\u0644\u062a\u063a\u0630\u064a\u0629 \u0642\u0628\u0644 \u0623\u0646 \u064a\u0646\u062e\u0641\u0636 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0644\u0644\u0645\u062d\u0631\u0643 \u0625\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0622\u0645\u0646 \u0648\u0642\u0628\u0644 \u0623\u0646 \u062a\u0635\u0628\u062d \u0639\u0644\u0627\u0642\u0629 \u0627\u0644\u0637\u0648\u0631 \u0628\u064a\u0646 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0648\u0627\u0644\u062a\u063a\u0630\u064a\u0629 \u0627\u0644\u0648\u0627\u0631\u062f\u0629 \u0645\u0644\u0627\u0626\u0645\u0629. \u0641\u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u062c\u0647\u062f\u0627\u0646 \u062e\u0627\u0631\u062c \u0627\u0644\u0637\u0648\u0631\u060c \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u0635\u0644 \u0641\u0631\u0642 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0644\u062d\u0638\u064a \u0628\u064a\u0646 \u0646\u0642\u0637\u062a\u064a \u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0642\u0627\u0637\u0639 \u0639\u0646\u062f \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0625\u0644\u0649 \u0636\u0639\u0641\u064a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0627\u0633\u0645\u064a. \u0648\u0642\u062f \u064a\u0628\u0644\u063a \u062a\u064a\u0627\u0631 \u0627\u0644\u0627\u0646\u062f\u0641\u0627\u0639 \u0627\u0644\u0646\u0627\u062a\u062c \u0623\u0636\u0639\u0627\u0641 \u062a\u064a\u0627\u0631 \u0628\u062f\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u0631\u062a\u0641\u0639 \u0623\u0635\u0644\u0627\u064b\u060c \u0643\u0645\u0627 \u0642\u062f \u064a\u0642\u0641\u0632 \u0627\u0644\u0639\u0632\u0645 \u0627\u0644\u0643\u0647\u0631\u0648\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0625\u0644\u0649 \u0642\u064a\u0645 \u062a\u0641\u0648\u0642 \u0639\u062f\u0629 \u0645\u0631\u0627\u062a \u0639\u0632\u0645 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0643\u0627\u0645\u0644 \u0627\u0644\u0627\u0633\u0645\u064a. \u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0627\u0633\u0645\u064a\u0629\u060c \u0642\u0627\u0631\u0646 \u0647\u0630\u0647 \u0627\u0644\u0638\u0631\u0648\u0641 \u0645\u0639 <a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker-ratings\/\">\u062f\u0644\u064a\u0644 \u062a\u0635\u0646\u064a\u0641\u0627\u062a VCB \u0648\u0627\u062e\u062a\u064a\u0627\u0631\u0647<\/a>.<\/p>\n<p>\u062a\u064f\u0635\u0645\u0645 \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0639\u0627\u062f\u0629 \u0644\u062a\u062d\u0645\u0644 \u0639\u0632\u0645 \u0627\u0644\u0628\u062f\u0621\u060c \u0644\u0627 \u0639\u0632\u0645 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u062e\u0627\u0631\u062c \u0627\u0644\u0637\u0648\u0631. \u0648\u0642\u062f \u062a\u062a\u0636\u0631\u0631 \u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0623\u0639\u0645\u062f\u0629 \u0648\u0639\u0644\u0628 \u0627\u0644\u062a\u0631\u0648\u0633 \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062f\u0627\u0631\u0629 \u0636\u0631\u0631\u0627\u064b \u0644\u0627 \u064a\u0638\u0647\u0631 \u0641\u0648\u0631\u0627\u064b \u0628\u0644 \u064a\u062a\u0631\u0627\u0643\u0645 \u0645\u0639 \u062a\u0643\u0631\u0627\u0631 \u0627\u0644\u0623\u062d\u062f\u0627\u062b. \u0648\u0644\u0627 \u062a\u0633\u062a\u0637\u064a\u0639 \u0628\u0639\u0636 \u0627\u0644\u0645\u0639\u062f\u0627\u062a\u060c \u0645\u062b\u0644 \u0645\u0631\u0627\u0648\u062d \u0627\u0644\u0645\u0636\u062e\u0627\u062a \u0648\u0645\u0643\u0627\u0628\u0633 \u0627\u0644\u0636\u0648\u0627\u063a\u0637 \u0648\u0631\u064a\u0634 \u0627\u0644\u062a\u0648\u0631\u0628\u064a\u0646\u0627\u062a\u060c \u062a\u062d\u0645\u0644 \u0627\u0644\u0635\u062f\u0645\u0629 \u0645\u0637\u0644\u0642\u0627\u064b. \u0643\u0645\u0627 \u0642\u062f \u062a\u062a\u0639\u0631\u0636 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643 \u0644\u0625\u062c\u0647\u0627\u062f \u0641\u064a \u0627\u0644\u0639\u0632\u0644 \u0628\u064a\u0646 \u0627\u0644\u0644\u0641\u0627\u062a \u064a\u0642\u0644\u0644 \u0639\u0645\u0631\u0647\u0627 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a.<\/p>\n<p>\u0644\u0647\u0630\u0647 \u0627\u0644\u0623\u0633\u0628\u0627\u0628\u060c \u0641\u0625\u0646 \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645 \u0644\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0639\u0644\u0649 \u0627\u0644\u062e\u0637\u0648\u0637 \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629\u060c \u0648\u0627\u0644\u0630\u064a \u064a\u0642\u0644 \u063a\u0627\u0644\u0628\u0627\u064b \u0639\u0646 \u062b\u0627\u0646\u064a\u0629 \u0641\u064a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u060c \u063a\u064a\u0631 \u0645\u0646\u0627\u0633\u0628 \u062a\u0645\u0627\u0645\u0627\u064b \u0644\u0645\u0639\u0638\u0645 \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a. \u0648\u0642\u062f \u0644\u0627 \u062a\u0643\u0641\u064a \u062d\u062a\u0649 \u0645\u0647\u0644\u0629 \u0645\u064a\u062a\u0629 \u0645\u062f\u062a\u0647\u0627 \u062b\u0644\u0627\u062b \u062b\u0648\u0627\u0646\u064d \u0644\u0645\u062d\u0631\u0643 \u0643\u0628\u064a\u0631 \u0630\u064a \u0642\u0635\u0648\u0631 \u0630\u0627\u062a\u064a \u0645\u0631\u062a\u0641\u0639.<\/p>\n<h3>\u0627\u0644\u062d\u0627\u0644\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0633\u062a\u0644\u0632\u0645 \u062a\u0639\u0637\u064a\u0644 \u0623\u0648 \u062d\u0638\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0639\u0644\u0649 \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a<\/h3>\n<p>\u0644\u0627 \u062a\u0648\u062c\u062f \u0642\u0627\u0639\u062f\u0629 \u0639\u0627\u0644\u0645\u064a\u0629 \u0648\u0627\u062d\u062f\u0629\u060c \u0644\u0643\u0646 \u0627\u0644\u0645\u0645\u0627\u0631\u0633\u0627\u062a \u0627\u0644\u0647\u0646\u062f\u0633\u064a\u0629 \u0648\u0625\u0631\u0634\u0627\u062f\u0627\u062a \u0645\u0635\u0646\u0639\u064a \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u062a\u062a\u0641\u0642 \u0639\u0644\u0649 \u062d\u0627\u0644\u0627\u062a \u0639\u062f\u064a\u062f\u0629 \u062a\u0633\u062a\u0644\u0632\u0645\u060c \u0643\u0644 \u0639\u0644\u0649 \u062d\u062f\u0629 \u0623\u0648 \u0645\u062c\u062a\u0645\u0639\u0629\u060c \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0623\u0648 \u062d\u0638\u0631\u0647\u0627.<\/p>\n<p>**\u0627\u0644\u0645\u063a\u0630\u064a \u064a\u063a\u0630\u064a \u0645\u062d\u0631\u0643\u0627\u064b \u0643\u0628\u064a\u0631\u0627\u064b \u0648\u0627\u062d\u062f\u0627\u064b.** \u0639\u0646\u062f\u0645\u0627 \u064a\u062a\u0643\u0648\u0646 \u062d\u0645\u0644 \u0627\u0644\u0645\u063a\u0630\u064a \u0643\u0644\u0647 \u0645\u0646 \u0645\u062d\u0631\u0643 \u0648\u0627\u062d\u062f\u060c \u0644\u0627 \u062a\u0648\u062c\u062f \u0641\u0627\u0626\u062f\u0629 \u062a\u0646\u0648\u064a\u0639 \u0645\u0646 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u0633\u064a\u0643\u0648\u0646 \u0627\u0644\u0645\u062d\u0631\u0643 \u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0636\u0645\u062d\u0644\u0627\u0644 \u0644\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0628\u0639\u062f \u0643\u0644 \u0641\u0635\u0644\u060c \u0623\u064a\u0627\u064b \u0643\u0627\u0646 \u0633\u0628\u0628\u0647. \u0648\u0645\u0627 \u0644\u0645 \u064a\u064f\u0637\u0628\u0642 \u0641\u062d\u0635 \u0627\u0644\u062a\u0632\u0627\u0645\u0646 \u0623\u0648 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a\u060c \u062a\u0643\u0648\u0646 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u063a\u064a\u0631 \u0622\u0645\u0646\u0629.<\/p>\n<p>**\u0627\u0644\u0645\u062d\u0631\u0643 \u064a\u0634\u063a\u0644 \u0645\u0639\u062f\u0627\u062a \u0639\u0645\u0644\u064a\u0629 \u062d\u0631\u062c\u0629 \u0623\u0648 \u0647\u0634\u0629.** \u0642\u062f \u062a\u062a\u062d\u0645\u0644 \u0645\u0636\u062e\u0627\u062a \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0648\u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u062a\u0643\u064a\u064a\u0641 \u0627\u0644\u0647\u0648\u0627\u0621 \u0635\u062f\u0645\u0629 \u0639\u0631\u0636\u064a\u0629 \u0623\u0641\u0636\u0644 \u0645\u0646 \u0636\u0648\u0627\u063a\u0637 \u0627\u0644\u0644\u0648\u0644\u0628 \u0627\u0644\u0645\u0641\u0631\u062f \u0623\u0648 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0637\u0631\u062f \u0627\u0644\u0645\u0631\u0643\u0632\u064a. \u0648\u0639\u0646\u062f\u0645\u0627 \u062a\u0643\u0648\u0646 \u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062f\u0627\u0631\u0629 \u0639\u0644\u0649 \u062a\u062d\u0645\u0644 \u0639\u0627\u0628\u0631\u0627\u062a \u0627\u0644\u0639\u0632\u0645 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0645\u0646\u062e\u0641\u0636\u0629\u060c \u064a\u062c\u0628 \u0645\u0646\u0639 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a.<\/p>\n<p>**\u0646\u0638\u0627\u0645 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0644\u0627 \u064a\u0636\u0645\u0646 \u062a\u0645\u064a\u064a\u0632 \u0627\u0644\u0623\u0639\u0637\u0627\u0644.** \u062a\u0641\u062a\u0631\u0636 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0639\u0644\u0649 \u0627\u0644\u0645\u063a\u0630\u064a \u0623\u0646 \u0627\u0644\u0645\u0631\u062d\u0644 \u064a\u0633\u062a\u0637\u064a\u0639 \u0627\u0644\u062a\u0645\u064a\u064a\u0632 \u0628\u064a\u0646 \u0639\u0637\u0644 \u0641\u064a \u0643\u0627\u0628\u0644 \u0627\u0644\u0645\u063a\u0630\u064a \u0648\u0639\u0637\u0644 \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u062d\u0631\u0643. \u0648\u0644\u0646 \u064a\u0632\u0648\u0644 \u0627\u0644\u0639\u0637\u0644 \u062f\u0627\u062e\u0644 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643 \u062e\u0644\u0627\u0644 \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a. \u0648\u0642\u062f \u062a\u0624\u062f\u064a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0639\u0644\u0649 \u0639\u0637\u0644 \u0641\u064a \u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0625\u0644\u0649 \u062a\u0641\u0627\u0642\u0645 \u0627\u0644\u0636\u0631\u0631 \u0628\u062f\u0631\u062c\u0629 \u0643\u0628\u064a\u0631\u0629. \u0648\u0625\u0630\u0627 \u0644\u0645 \u062a\u062a\u0648\u0641\u0631 \u062d\u0645\u0627\u064a\u0629 \u062a\u0641\u0627\u0636\u0644\u064a\u0629 \u0623\u0648 \u0648\u0633\u064a\u0644\u0629 \u0623\u062e\u0631\u0649 \u0644\u0643\u0634\u0641 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062f\u0627\u062e\u0644\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643\u060c \u062a\u0631\u062c\u062d \u0645\u0648\u0627\u0632\u0646\u0629 \u0627\u0644\u0645\u062e\u0627\u0637\u0631 \u0648\u0627\u0644\u0641\u0648\u0627\u0626\u062f \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0642\u0641\u0644.<\/p>\n<p>**\u0627\u0644\u0645\u0631\u062d\u0644 \u0645\u0636\u0628\u0648\u0637 \u0639\u0644\u0649 \u0648\u0636\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u062d\u0631\u0643.** \u0643\u0645\u0627 \u0630\u064f\u0643\u0631 \u0623\u0639\u0644\u0627\u0647\u060c \u064a\u0633\u062a\u0628\u0639\u062f \u0648\u0636\u0639 \u0627\u0644\u0645\u062d\u0631\u0643 \u0641\u064a \u0627\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u0627\u0644\u0631\u0642\u0645\u064a\u0629 \u0627\u0644\u062d\u062f\u064a\u062b\u0629 \u0639\u0627\u062f\u0629\u064b \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0645\u062a\u0627\u062d\u0629. \u0648\u0625\u0630\u0627 \u0636\u064f\u0628\u0637 \u0648\u0636\u0639 \u0627\u0644\u0645\u0631\u062d\u0644 \u0628\u0635\u0648\u0631\u0629 \u0635\u062d\u064a\u062d\u0629 \u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0641\u0644\u0627 \u064a\u0646\u0628\u063a\u064a \u062a\u0645\u0643\u064a\u0646 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a.<\/p>\n<p>**\u0627\u0633\u062a\u0645\u0631\u0627\u0631\u064a\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u062a\u062a\u0637\u0644\u0628 \u0625\u0639\u0627\u062f\u0629 \u062a\u0634\u063a\u064a\u0644 \u0645\u0636\u0628\u0648\u0637\u0629.** \u062a\u062a\u0637\u0644\u0628 \u0639\u0645\u0644\u064a\u0627\u062a \u0635\u0646\u0627\u0639\u064a\u0629 \u0643\u062b\u064a\u0631\u0629 \u0625\u0639\u0627\u062f\u0629 \u062a\u0634\u063a\u064a\u0644 \u0645\u062a\u062a\u0627\u0628\u0639\u0629 \u0648\u0645\u0636\u0628\u0648\u0637\u0629 \u0628\u0639\u062f \u0627\u0644\u0641\u0635\u0644. \u0648\u062a\u062a\u062c\u0627\u0648\u0632 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0645\u0646\u0637\u0642 \u062a\u0639\u0634\u064a\u0642 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0641\u064a \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u0639\u0645\u0644\u064a\u0629\u060c \u0648\u0642\u062f \u062a\u0639\u064a\u062f \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0642\u0628\u0644 \u0623\u0646 \u062a\u0635\u0628\u062d \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0644\u0644\u0645\u0639\u062f\u0629 \u0627\u0644\u0645\u062f\u0627\u0631\u0629 \u0622\u0645\u0646\u0629.<\/p>\n<p>**\u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u064a\u0633\u062a\u062e\u062f\u0645 \u062d\u0645\u0627\u064a\u0629 \u0648\u062d\u062f\u0648\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643.** \u0639\u0646\u062f\u0645\u0627 \u064a\u0643\u0648\u0646 VCB \u062c\u0632\u0621\u0627\u064b \u0645\u0646 \u0645\u062e\u0637\u0637 \u062d\u0645\u0627\u064a\u0629 \u0648\u062d\u062f\u0648\u064a\u0629 \u064a\u062a\u0636\u0645\u0646 \u0639\u0646\u0627\u0635\u0631 \u062a\u0641\u0627\u0636\u0644\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643\u060c \u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u0624\u062f\u064a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u0641\u0627\u0636\u0644\u064a \u0625\u0644\u0649 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a. \u0648\u064a\u0646\u0628\u063a\u064a \u062a\u0647\u064a\u0626\u0629 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u0641\u0627\u0636\u0644\u064a \u0643\u0645\u062f\u062e\u0644 \u062d\u0638\u0631 \u0644\u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0628\u0646\u064a\u0629 \u0627\u0644\u062d\u0638\u0631 \u0628\u0627\u0644\u0645\u062f\u062e\u0644 \u0627\u0644\u0631\u0642\u0645\u064a \u0627\u0644\u0645\u0648\u0636\u062d\u0629 \u0641\u064a \u0648\u062b\u0627\u0626\u0642 \u0645\u0631\u062d\u0644\u0627\u062a ABB.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-reclose-logic-in-motor-feeders-when-to-disable-auto-reclose-fig-03.webp\" alt=\"\u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB \u0641\u064a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0645\u0646 XBRELE: \u0645\u062a\u0649 \u064a\u062c\u0628 \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a - \u0633\u064a\u0627\u0642 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\" \/><\/figure>\n<h3>\u062a\u0637\u0628\u064a\u0642 \u0645\u0646\u0637\u0642 \u0627\u0644\u062d\u0638\u0631 \u0641\u064a \u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a VCB<\/h3>\n<p>\u0625\u0630\u0627 \u0631\u064f\u0643\u0628 \u0627\u0644\u0645\u0631\u062d\u0644 \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a \u0644\u0643\u0646\u0647 \u064a\u062e\u062f\u0645 \u0623\u064a\u0636\u0627\u064b \u0645\u062d\u0631\u0643\u0627\u062a \u0639\u0644\u0649 \u0645\u063a\u0630\u064d \u0645\u062e\u062a\u0644\u0637\u060c \u064a\u0643\u0648\u0646 \u0627\u0644\u062d\u0644 \u0627\u0644\u0647\u0646\u062f\u0633\u064a \u0627\u0644\u0645\u0644\u0627\u0626\u0645 \u0647\u0648 \u0627\u0644\u062d\u0638\u0631 \u0627\u0644\u0627\u0646\u062a\u0642\u0627\u0626\u064a \u0644\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0644\u0623\u0646\u0648\u0627\u0639 \u0645\u0639\u064a\u0646\u0629 \u0645\u0646 \u0627\u0644\u0641\u0635\u0644. \u0648\u062a\u0642\u062f\u0645 \u0628\u0646\u064a\u0629 ABB \u0646\u0645\u0648\u0630\u062c\u0627\u064b \u0644\u0630\u0644\u0643: \u064a\u0645\u0643\u0646 \u062d\u0638\u0631 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0628\u0625\u0634\u0627\u0631\u0627\u062a \u0641\u0635\u0644 \u062d\u0645\u0627\u064a\u0629 \u0645\u062e\u062a\u0627\u0631\u0629 \u0623\u0648 \u0628\u0645\u062f\u062e\u0644 \u0631\u0642\u0645\u064a.<\/p>\n<p>\u0639\u0645\u0644\u064a\u0627\u064b\u060c \u064a\u0639\u0646\u064a \u0630\u0644\u0643 \u0631\u0628\u0637 \u0625\u0634\u0627\u0631\u0627\u062a \u062e\u0631\u062c \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0628\u0645\u062f\u062e\u0644 \u062d\u0638\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0641\u0642\u0627\u064b \u0644\u0644\u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062a\u064a \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0645\u0646\u0639\u0647\u0627. \u0648\u064a\u062c\u0628 \u0623\u0646 \u062a\u062f\u062e\u0644 \u0641\u064a \u0645\u0646\u0637\u0642 \u0627\u0644\u062d\u0638\u0631 \u0641\u0635\u0648\u0644 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0644\u0627\u062d\u0642\u0629\u060c \u0648\u0641\u0635\u0648\u0644 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0623\u0631\u0636\u064a \u0641\u064a \u0647\u064a\u0643\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0648\u0641\u0635\u0648\u0644 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0627\u0644\u0632\u0627\u0626\u062f. \u0623\u0645\u0627 \u0641\u0635\u0648\u0644 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0623\u0639\u0637\u0627\u0644 \u0633\u0627\u0628\u0642\u0629 \u0644\u0644\u0645\u063a\u0630\u064a \u0623\u0648 \u0623\u0639\u0637\u0627\u0644 \u0643\u0627\u0628\u0644 \u0627\u0644\u0645\u063a\u0630\u064a\u060c \u0639\u0646\u062f\u0645\u0627 \u064a\u062b\u0642 \u0627\u0644\u0645\u0647\u0646\u062f\u0633 \u0628\u0623\u0646 \u0627\u0644\u0639\u0637\u0644 \u0641\u064a \u0627\u0644\u0643\u0627\u0628\u0644 \u0644\u0627 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0641\u064a\u0645\u0643\u0646 \u0627\u0644\u0633\u0645\u0627\u062d \u0644\u0647\u0627 \u0628\u0628\u062f\u0621 \u0645\u062d\u0627\u0648\u0644\u0629 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642\u060c \u0634\u0631\u064a\u0637\u0629 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a. \u0631\u0627\u062c\u0639 <a href=\"https:\/\/xbrele.com\/ar\/vcb-closing-opening-failure-troubleshooting\/\">\u062f\u0644\u064a\u0644 \u0623\u0639\u0637\u0627\u0644 \u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0642\u0627\u0637\u0639 \u0648\u0641\u062a\u062d\u0647<\/a> \u0644\u062a\u0645\u064a\u064a\u0632 \u0623\u0633\u0628\u0627\u0628 \u0639\u0637\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u0648 \u0627\u0644\u0645\u0644\u0641 \u0623\u0648 \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0623\u0648 \u0627\u0644\u0622\u0644\u064a\u0629 \u0628\u0639\u062f \u0641\u0634\u0644 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644.<\/p>\n<p>\u064a\u0648\u0641\u0631 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a\u060c \u0627\u0644\u0645\u0646\u0641\u0630 \u0643\u0641\u062d\u0635 \u0627\u0646\u062e\u0641\u0627\u0636 \u062c\u0647\u062f \u0639\u0628\u0631 \u0645\u062d\u0648\u0644 \u062c\u0647\u062f \u0627\u0644\u0642\u0636\u0628\u0627\u0646 \u0641\u064a \u062c\u0627\u0646\u0628 \u0627\u0644\u062d\u0645\u0644\u060c \u0637\u0628\u0642\u0629 \u0623\u0645\u0627\u0646 \u0625\u0636\u0627\u0641\u064a\u0629. \u0641\u0625\u0630\u0627 \u0644\u0645 \u064a\u0646\u062e\u0641\u0636 \u062c\u0647\u062f \u062c\u0627\u0646\u0628 \u0627\u0644\u062d\u0645\u0644 \u062f\u0648\u0646 \u0639\u062a\u0628\u0629 \u2014 \u0645\u062b\u0644 20 \u0625\u0644\u0649 25 \u0628\u0627\u0644\u0645\u0626\u0629 \u0645\u0646 \u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0627\u0633\u0645\u064a\u0629 \u2014 \u0639\u0646\u062f \u0646\u0647\u0627\u064a\u0629 \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a\u060c \u064a\u064f\u062d\u0638\u0631 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u062f\u062e\u0644 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u064a \u062d\u0627\u0644\u0629 \u0642\u0641\u0644. \u0648\u064a\u0634\u0628\u0647 \u0630\u0644\u0643 \u0645\u0631\u062d\u0644 \u0641\u062d\u0635 \u0627\u0644\u062a\u0632\u0627\u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u062a\u0648\u0644\u064a\u062f\u060c \u0648\u064a\u0648\u0641\u0631 \u062d\u0645\u0627\u064a\u0629 \u0645\u0628\u0627\u0634\u0631\u0629 \u0642\u0627\u0626\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u064a\u0627\u0633 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0627\u0639\u062a\u0645\u0627\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0624\u0642\u062a \u0648\u062d\u062f\u0647.<\/p>\n<p>\u064a\u062c\u0628 \u0623\u0646 \u064a\u0643\u0648\u0646 VCB \u0646\u0641\u0633\u0647 \u062c\u0627\u0647\u0632\u0627\u064b \u0644\u0644\u0625\u063a\u0644\u0627\u0642 \u0628\u0635\u0648\u0631\u0629 \u0645\u0648\u062b\u0648\u0642\u0629 \u0639\u0646\u062f \u062a\u0644\u0642\u064a \u0627\u0644\u0623\u0645\u0631. \u0648\u062a\u062f\u062e\u0644 \u0646\u0642\u0627\u0637 \u062a\u0644\u0627\u0645\u0633 \u0645\u0648\u0636\u0639 \u0627\u0644\u0642\u0627\u0637\u0639 \u0648\u062d\u0627\u0644\u0629 \u0634\u062d\u0646 \u0627\u0644\u0646\u0627\u0628\u0636 \u0648\u062d\u0627\u0644\u0629 \u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0641\u064a \u0634\u0631\u0637 \u0627\u0644\u062c\u0627\u0647\u0632\u064a\u0629 \u0644\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u0625\u0630\u0627 \u0623\u062e\u0641\u0642 VCB \u0641\u064a \u0634\u062d\u0646 \u0646\u0627\u0628\u0636 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0636\u0645\u0646 \u0627\u0644\u0645\u0647\u0644\u0629 \u0627\u0644\u0645\u0633\u0645\u0648\u062d \u0628\u0647\u0627 \u2014 \u0648\u0647\u064a \u062d\u0627\u0644\u0629 \u062a\u063a\u0637\u064a\u0647\u0627 \u0628\u0627\u0644\u062a\u0641\u0635\u064a\u0644 \u0623\u062f\u0644\u0629 \u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0641\u062a\u062d \u2014 \u0641\u064a\u062c\u0628 \u0625\u0644\u063a\u0627\u0621 \u062a\u0633\u0644\u0633\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0625\u0635\u062f\u0627\u0631 \u0623\u0645\u0631 \u0644\u0646 \u064a\u064f\u0646\u0641\u0630.<\/p>\n<h3>\u0641\u062d\u0648\u0635 \u062a\u0634\u063a\u064a\u0644 \u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0644\u0642\u0648\u0627\u0637\u0639 VCB \u0639\u0644\u0649 \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a<\/h3>\n<p>\u064a\u062a\u0637\u0644\u0628 \u062a\u0634\u063a\u064a\u0644 VCB \u0639\u0644\u0649 \u0645\u063a\u0630\u064d \u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u062a\u062d\u0642\u0642 \u0635\u0631\u0627\u062d\u0629\u064b \u0645\u0646 \u0636\u0628\u0637 \u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0643\u0648\u0646 \u0627\u0644\u0641\u062d\u0648\u0635 \u0627\u0644\u062a\u0627\u0644\u064a\u0629 \u062c\u0632\u0621\u0627\u064b \u0645\u0646 \u0648\u062b\u0627\u0626\u0642 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0641\u064a \u0627\u0644\u0645\u0635\u0646\u0639 \u0648\u0627\u0644\u0645\u0648\u0642\u0639. \u064a\u0648\u0641\u0631 <a href=\"https:\/\/xbrele.com\/ar\/vcb-fat-sat-acceptance-test-checklist\/\">\u062f\u0644\u064a\u0644 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 FAT\/SAT \u0644\u0644\u0642\u0627\u0637\u0639<\/a> \u0647\u064a\u0643\u0644\u0627\u064b \u0645\u0643\u0645\u0644\u0627\u064b \u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0648\u0627\u0644\u0646\u062a\u0627\u0626\u062c \u0648\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0625\u0642\u0641\u0627\u0644.<\/p>\n<p>\u0623\u0648\u0644\u0627\u064b\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u0648\u0636\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0631\u062d\u0644. \u064a\u062c\u0628 \u0636\u0628\u0637 \u0645\u0631\u062d\u0644 \u0645\u063a\u0630\u064d \u0645\u062e\u0635\u0635 \u0644\u0645\u062d\u0631\u0643 \u0639\u0644\u0649 \u0648\u0636\u0639 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0645\u0639 \u063a\u064a\u0627\u0628 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0623\u0648 \u062d\u0638\u0631\u0647\u0627. \u0648\u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0645\u0631\u062d\u0644 \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a \u0644\u0623\u064a \u0633\u0628\u0628\u060c \u0641\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0631\u0628\u0637 \u0627\u0644\u0635\u062d\u064a\u062d \u0644\u0645\u062f\u062e\u0644\u0627\u062a \u0627\u0644\u062d\u0638\u0631.<\/p>\n<p>\u062b\u0627\u0646\u064a\u0627\u064b\u060c \u0627\u062d\u0642\u0646 \u062a\u064a\u0627\u0631 \u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0628\u0631 \u0643\u0644 \u0639\u0646\u0635\u0631 \u062d\u0645\u0627\u064a\u0629 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u064a\u062d\u0638\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0648\u062a\u062d\u0642\u0642 \u0645\u0646 \u0648\u0635\u0648\u0644 \u0625\u0634\u0627\u0631\u0629 \u0627\u0644\u062d\u0638\u0631 \u0625\u0644\u0649 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0645\u0646\u0639\u0647\u0627 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u064a\u062c\u0628 \u062a\u0646\u0641\u064a\u0630 \u0647\u0630\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0644\u0643\u0644 \u0639\u0646\u0635\u0631 \u0639\u0644\u0649 \u062d\u062f\u0629.<\/p>\n<p>\u062b\u0627\u0644\u062b\u0627\u064b\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a. \u0648\u0625\u0630\u0627 \u0633\u064f\u0645\u062d \u0628\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0644\u0623\u064a \u0639\u0646\u0635\u0631 \u0641\u0635\u0644\u060c \u0641\u062a\u0623\u0643\u062f \u0645\u0646 \u0623\u0646 \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a \u0643\u0627\u0641\u064d \u0644\u0627\u0636\u0645\u062d\u0644\u0627\u0644 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0644\u0644\u0645\u062d\u0631\u0643. \u0648\u064a\u064f\u0633\u062a\u062e\u062f\u0645 \u0639\u0627\u062f\u0629\u064b \u0632\u0645\u0646 \u0645\u064a\u062a \u0644\u0627 \u064a\u0642\u0644 \u0639\u0646 \u062e\u0645\u0633 \u0625\u0644\u0649 \u0639\u0634\u0631 \u062b\u0648\u0627\u0646\u064d \u0644\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062a\u062c\u0627\u0648\u0632 \u0642\u062f\u0631\u062a\u0647\u0627 \u0646\u062d\u0648 150 kW\u061b \u0623\u0645\u0627 \u0627\u0644\u0622\u0644\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u062c\u062f\u0627\u064b \u0641\u062a\u062d\u062a\u0627\u062c \u0632\u0645\u0646\u0627\u064b \u0623\u0637\u0648\u0644 \u0623\u0648 \u0625\u0634\u0631\u0627\u0641\u0627\u064b \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a.<\/p>\n<p>\u0631\u0627\u0628\u0639\u0627\u064b\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u0641\u062d\u0635 \u062c\u0627\u0647\u0632\u064a\u0629 \u0627\u0644\u0642\u0627\u0637\u0639. \u0645\u0639 \u0641\u062a\u062d VCB \u0648\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0646\u0627\u0628\u0636\u060c \u062a\u0623\u0643\u062f \u0645\u0646 \u062d\u0638\u0631 \u0623\u0645\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0625\u0644\u0649 \u0623\u0646 \u064a\u064f\u0639\u0627\u062f \u0634\u062d\u0646 \u0627\u0644\u0646\u0627\u0628\u0636 \u0648\u064a\u062a\u062d\u0642\u0642 \u0634\u0631\u0637 \u0627\u0644\u062c\u0627\u0647\u0632\u064a\u0629 \u0644\u0644\u0625\u063a\u0644\u0627\u0642.<\/p>\n<p>\u062e\u0627\u0645\u0633\u0627\u064b\u060c \u0627\u062e\u062a\u0628\u0631 \u0633\u0644\u0648\u0643 \u0627\u0644\u0642\u0641\u0644. \u0628\u0639\u062f \u0628\u0644\u0648\u063a \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u0639\u062f\u062f \u0645\u062d\u0627\u0648\u0644\u0627\u062a \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u0628\u0631\u0645\u062c\u060c \u062a\u062d\u0642\u0642 \u0645\u0646 \u062f\u062e\u0648\u0644 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0641\u064a \u0627\u0644\u0642\u0641\u0644 \u0648\u0645\u0646 \u0636\u0631\u0648\u0631\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0636\u0628\u0637 \u064a\u062f\u0648\u064a\u0627\u064b \u0644\u0645\u0646\u0639 \u0623\u064a \u0623\u0648\u0627\u0645\u0631 \u0625\u063a\u0644\u0627\u0642 \u062a\u0644\u0642\u0627\u0626\u064a\u0629 \u0623\u062e\u0631\u0649.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-reclose-logic-in-motor-feeders-when-to-disable-auto-reclose-fig-04.webp\" alt=\"\u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB \u0641\u064a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0645\u0646 XBRELE: \u0645\u062a\u0649 \u064a\u062c\u0628 \u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a - \u062a\u0633\u0644\u064a\u0645 \u0627\u0644\u062a\u0648\u0631\u064a\u062f\" \/><\/figure>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3>\u0645\u0627 \u0627\u0644\u0633\u0628\u0628 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u0644\u062a\u0639\u0637\u064a\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0644\u0642\u0627\u0637\u0639 VCB \u0639\u0644\u0649 \u0645\u063a\u0630\u064d \u0644\u0645\u062d\u0631\u0643\u061f<\/h3>\n<p>\u0627\u0644\u0633\u0628\u0628 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u0647\u0648 \u062e\u0637\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u062e\u0627\u0631\u062c \u0627\u0644\u0637\u0648\u0631 \u0639\u0644\u0649 \u0645\u062d\u0631\u0643 \u0644\u0627 \u064a\u0632\u0627\u0644 \u064a\u0648\u0644\u062f \u062c\u0647\u062f\u0627\u064b \u0645\u062a\u0628\u0642\u064a\u0627\u064b. \u0641\u0639\u0646\u062f\u0645\u0627 \u064a\u0641\u0635\u0644 \u0645\u062d\u0631\u0643 \u064a\u0639\u0645\u0644\u060c \u064a\u0636\u0645\u062d\u0644 \u0627\u0644\u0641\u064a\u0636 \u0627\u0644\u062f\u0648\u0627\u0631 \u062a\u062f\u0631\u064a\u062c\u064a\u0627\u064b \u0648\u064a\u062a\u063a\u064a\u0631 \u0637\u0648\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0637\u0631\u0641\u064a \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u063a\u0630\u064a\u0629. \u0648\u0625\u0630\u0627 \u0623\u0639\u0627\u062f VCB \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0642\u0628\u0644 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0625\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0622\u0645\u0646\u060c \u0641\u0642\u062f \u064a\u0624\u062f\u064a \u0641\u0631\u0642 \u0627\u0644\u062c\u0647\u062f \u0628\u064a\u0646 \u0646\u0642\u0637\u062a\u064a \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0644\u062d\u0638\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0625\u0644\u0649 \u062a\u064a\u0627\u0631\u0627\u062a \u0627\u0646\u062f\u0641\u0627\u0639 \u0648\u0642\u0641\u0632\u0627\u062a \u0639\u0632\u0645 \u062a\u062a\u0644\u0641 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643 \u0648\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u0639\u0645\u0648\u062f \u0648\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u062f\u0627\u0631\u0629. \u0648\u0639\u0644\u0649 \u062e\u0644\u0627\u0641 \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u062e\u0637\u0648\u0637 \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629 \u0627\u0644\u062a\u064a \u062a\u0643\u0648\u0646 \u0639\u0627\u0628\u0631\u0629 \u0648\u062a\u0632\u0648\u0644 \u0630\u0627\u062a\u064a\u0627\u064b \u063a\u0627\u0644\u0628\u0627\u064b\u060c \u0644\u0627 \u062a\u0633\u062a\u0641\u064a\u062f \u0623\u0639\u0637\u0627\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0623\u0648 \u0627\u0646\u0642\u0637\u0627\u0639\u0627\u062a \u0627\u0644\u062a\u063a\u0630\u064a\u0629 \u0645\u0646 \u0627\u0644\u0645\u0646\u0637\u0642 \u0646\u0641\u0633\u0647 \u0627\u0644\u0630\u064a \u064a\u0628\u0631\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0639\u0644\u0649 \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639.<\/p>\n<h3>\u0645\u0627 \u062f\u0648\u0631 \u0648\u0636\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0631\u062d\u0644 \u0641\u064a \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642 VCB\u061f<\/h3>\n<p>\u0648\u0636\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0631\u062d\u0644 \u0622\u0644\u064a\u0629 \u062a\u0647\u064a\u0626\u0629 \u062a\u062d\u062f\u062f \u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u062a\u0627\u062d\u0629. \u0641\u0645\u062b\u0644\u0627\u064b \u062a\u0641\u0635\u0644 \u0645\u0646\u062a\u062c\u0627\u062a \u0645\u0631\u062d\u0644\u0627\u062a Schneider Electric \u0628\u064a\u0646 \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a\u060c \u0627\u0644\u0630\u064a \u064a\u062a\u0636\u0645\u0646 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a\u060c \u0648\u0648\u0636\u0639 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0627\u0644\u0630\u064a \u064a\u0648\u0641\u0631 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0628\u062f\u0621 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0631\u0643 \u0648\u062d\u0645\u0627\u064a\u0627\u062a \u062e\u0627\u0635\u0629 \u0628\u0647. \u0644\u0630\u0644\u0643 \u064a\u0624\u062f\u064a \u0636\u0628\u0637 \u0627\u0644\u0645\u0631\u062d\u0644 \u0639\u0644\u0649 \u0648\u0636\u0639 \u0627\u0644\u0645\u062d\u0631\u0643 \u0641\u064a \u062a\u0637\u0628\u064a\u0642 \u0645\u063a\u0630\u064a \u0627\u0644\u0645\u062d\u0631\u0643 \u0625\u0644\u0649 \u0627\u0633\u062a\u0628\u0639\u0627\u062f \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0628\u0646\u064a\u0648\u064a\u0627\u064b \u0645\u0646 \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0645\u062a\u0627\u062d\u0629. \u0648\u0647\u0630\u0627 \u0644\u064a\u0633 \u0642\u0635\u0648\u0631\u0627\u064b\u060c \u0628\u0644 \u0645\u064a\u0632\u0629 \u062a\u0635\u0645\u064a\u0645 \u062a\u0641\u0631\u0636 \u0647\u0646\u062f\u0633\u0629 \u0627\u0644\u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0635\u062d\u064a\u062d\u0629. \u0648\u064a\u062c\u0628 \u0623\u0644\u0627 \u064a\u062a\u062c\u0627\u0648\u0632 \u0627\u0644\u0645\u0647\u0646\u062f\u0633\u0648\u0646 \u0630\u0644\u0643 \u0628\u0627\u062e\u062a\u064a\u0627\u0631 \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a \u0644\u0645\u062c\u0631\u062f \u0625\u062a\u0627\u062d\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0639\u0644\u0649 \u0645\u063a\u0630\u064a \u0645\u062d\u0631\u0643\u060c \u0644\u0623\u0646 \u0630\u0644\u0643 \u064a\u062e\u0644 \u0628\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0639\u0627\u0645 \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0648\u0641\u0642 IEC\/EN 60947-4-1.<\/p>\n<h3>\u0645\u0627 \u0648\u0638\u064a\u0641\u0629 \u0645\u062f\u062e\u0644 \u0627\u0644\u062d\u0638\u0631 \u0641\u064a \u0645\u062e\u0637\u0637 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a\u061f<\/h3>\n<p>\u0645\u062f\u062e\u0644 \u0627\u0644\u062d\u0638\u0631 \u0645\u0633\u0627\u0631 \u0625\u0634\u0627\u0631\u0629 \u064a\u0645\u0646\u0639 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0645\u0646 \u0625\u0635\u062f\u0627\u0631 \u0623\u0645\u0631 \u0625\u063a\u0644\u0627\u0642 \u0639\u0646\u062f \u062a\u0641\u0639\u064a\u0644\u0647\u060c \u0628\u0635\u0631\u0641 \u0627\u0644\u0646\u0638\u0631 \u0639\u0646 \u0627\u0646\u062a\u0647\u0627\u0621 \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a \u0623\u0648 \u062c\u0627\u0647\u0632\u064a\u0629 \u0627\u0644\u0642\u0627\u0637\u0639 \u0644\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u062a\u062a\u0636\u0645\u0646 \u0628\u0646\u064a\u0629 \u0645\u0631\u062d\u0644\u0627\u062a ABB \u0647\u0630\u0647 \u0627\u0644\u0642\u062f\u0631\u0629 \u0635\u0631\u0627\u062d\u0629\u064b\u060c \u0628\u062d\u064a\u062b \u064a\u0645\u0643\u0646 \u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0641\u0635\u0644 \u0645\u062e\u062a\u0627\u0631\u0629 \u0623\u0648 \u0645\u062f\u0627\u062e\u0644 \u0631\u0642\u0645\u064a\u0629 \u062e\u0627\u0631\u062c\u064a\u0629 \u0645\u0646\u0639 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0645\u063a\u0630\u064a\u0627\u062a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a\u060c \u062a\u064f\u0633\u062a\u062e\u062f\u0645 \u0647\u0630\u0647 \u0627\u0644\u0622\u0644\u064a\u0629 \u0644\u0636\u0645\u0627\u0646 \u0623\u0644\u0627 \u062a\u0624\u062f\u064a \u0627\u0644\u0641\u0635\u0648\u0644 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062a\u0641\u0627\u0636\u0644\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643 \u0623\u0648 \u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u062d\u0631\u0627\u0631\u064a \u0627\u0644\u0632\u0627\u0626\u062f \u0623\u0648 \u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u0639\u0637\u0644 \u0627\u0644\u0623\u0631\u0636\u064a \u0625\u0644\u0649 \u0628\u062f\u0621 \u062f\u0648\u0631\u0629 \u0625\u0639\u0627\u062f\u0629 \u0625\u063a\u0644\u0627\u0642. \u0648\u064a\u062d\u062f\u062f \u0627\u0644\u0645\u0647\u0646\u062f\u0633 \u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u064a \u062a\u0633\u0645\u062d \u0628\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u0644\u0643 \u0627\u0644\u062a\u064a \u062a\u0633\u062a\u0644\u0632\u0645 \u0627\u0644\u0642\u0641\u0644\u060c \u0648\u064a\u0646\u0641\u0630 \u0630\u0644\u0643 \u0639\u0628\u0631 \u0631\u0628\u0637 \u0645\u062f\u062e\u0644 \u0627\u0644\u062d\u0638\u0631 \u0641\u064a \u0627\u0644\u0645\u0631\u062d\u0644.<\/p>\n<h3>\u0645\u0627 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0648\u0643\u064a\u0641 \u064a\u062d\u0645\u064a \u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0623\u062b\u0646\u0627\u0621 \u062a\u0633\u0644\u0633\u0644 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u061f<\/h3>\n<p>\u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0647\u0648 \u062a\u0639\u0634\u064a\u0642 \u0642\u0627\u0626\u0645 \u0639\u0644\u0649 \u0627\u0644\u0642\u064a\u0627\u0633 \u064a\u0631\u0627\u0642\u0628 \u0627\u0644\u062c\u0647\u062f \u0641\u064a \u062c\u0627\u0646\u0628 \u0627\u0644\u062d\u0645\u0644 \u0645\u0646 VCB \u0628\u0639\u062f \u0627\u0644\u0641\u0635\u0644. \u0641\u0625\u0630\u0627 \u0644\u0645 \u064a\u0646\u062e\u0641\u0636 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0637\u0631\u0641\u064a \u0627\u0644\u0645\u062a\u0646\u0627\u0642\u0635 \u0644\u0644\u0645\u062d\u0631\u0643 \u0639\u0646 \u0639\u062a\u0628\u0629 \u0645\u062d\u062f\u062f\u0629 \u2014 \u0639\u0627\u062f\u0629\u064b 20 \u0625\u0644\u0649 25 \u0628\u0627\u0644\u0645\u0626\u0629 \u0645\u0646 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0627\u0633\u0645\u064a \u0627\u0644\u0645\u0642\u0646\u0646 \u2014 \u0639\u0646\u062f \u0646\u0647\u0627\u064a\u0629 \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a\u060c \u062a\u064f\u062d\u0638\u0631 \u0648\u0638\u064a\u0641\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0648\u062a\u062f\u062e\u0644 \u062f\u0648\u0631\u0629 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u064a \u0627\u0644\u0642\u0641\u0644 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0645\u062a\u0627\u0628\u0639\u0629. \u0648\u064a\u062a\u064a\u062d \u0630\u0644\u0643 \u0642\u064a\u0627\u0633 \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643 \u0645\u0628\u0627\u0634\u0631\u0629\u064b \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0627\u0639\u062a\u0645\u0627\u062f \u062d\u0635\u0631\u0627\u064b \u0639\u0644\u0649 \u0645\u0624\u0642\u062a \u0628\u0632\u0645\u0646 \u0645\u064a\u062a \u062b\u0627\u0628\u062a. \u0648\u0647\u0648 \u0645\u0647\u0645 \u062e\u0635\u0648\u0635\u0627\u064b \u0644\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629 \u0630\u0627\u062a \u0627\u0644\u0642\u0635\u0648\u0631 \u0627\u0644\u0630\u0627\u062a\u064a \u0627\u0644\u0645\u0631\u062a\u0641\u0639\u060c \u0627\u0644\u062a\u064a \u0642\u062f \u062a\u062d\u062a\u0641\u0638 \u0628\u062c\u0647\u062f \u0645\u062a\u0628\u0642\u064d \u0643\u0628\u064a\u0631 \u0644\u0639\u062f\u0629 \u062b\u0648\u0627\u0646\u064d \u0628\u0639\u062f \u0627\u0644\u0641\u0635\u0644\u060c \u0643\u0645\u0627 \u064a\u0634\u0628\u0647 \u0645\u0631\u062d\u0644 \u0641\u062d\u0635 \u0627\u0644\u062a\u0632\u0627\u0645\u0646 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645 \u0641\u064a \u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u0648\u0644\u062f\u0627\u062a.<\/p>\n<h3>\u0645\u0627 \u0627\u0644\u0646\u0647\u062c \u0627\u0644\u0635\u062d\u064a\u062d \u0644\u062a\u0634\u063a\u064a\u0644 VCB \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0646\u0637\u0642 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0639\u0644\u0649 \u0645\u063a\u0630\u064d \u0644\u0645\u062d\u0631\u0643\u061f<\/h3>\n<p>\u064a\u062a\u0636\u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0635\u062d\u064a\u062d \u0639\u062f\u0629 \u062e\u0637\u0648\u0627\u062a \u062a\u062d\u0642\u0642 \u0645\u0646\u0641\u0635\u0644\u0629 \u064a\u0646\u0628\u063a\u064a \u062a\u0648\u062b\u064a\u0642\u0647\u0627 \u0641\u064a \u0633\u062c\u0644\u0627\u062a \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0642\u0628\u0648\u0644 \u0641\u064a \u0627\u0644\u0645\u0635\u0646\u0639 \u0648\u0627\u0644\u0645\u0648\u0642\u0639. \u064a\u062c\u0628 \u0639\u0644\u0649 \u0627\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0623\u0648\u0644\u0627\u064b \u062a\u0623\u0643\u064a\u062f \u0648\u0636\u0639 \u062a\u0637\u0628\u064a\u0642 \u0627\u0644\u0645\u0631\u062d\u0644 \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u063a\u064a\u0627\u0628 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a \u0623\u0648 \u062d\u0638\u0631\u0647\u0627 \u0639\u0644\u0649 \u0646\u062d\u0648 \u0635\u062d\u064a\u062d. \u0648\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u0631\u062d\u0644\u0627\u062a \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u0645\u063a\u0630\u064a\u060c \u064a\u062c\u0628 \u0627\u062e\u062a\u0628\u0627\u0631 \u0643\u0644 \u0639\u0646\u0635\u0631 \u062d\u0645\u0627\u064a\u0629 \u064a\u0641\u062a\u0631\u0636 \u0623\u0646 \u064a\u062d\u0638\u0631 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0639\u0644\u0649 \u062d\u062f\u0629 \u0628\u062d\u0642\u0646 \u062a\u064a\u0627\u0631 \u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0648\u0635\u0648\u0644 \u0625\u0634\u0627\u0631\u0629 \u0627\u0644\u062d\u0638\u0631 \u0625\u0644\u0649 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0648\u0645\u0646\u0639\u0647\u0627. \u0648\u064a\u062c\u0628 \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0645\u0644\u0627\u0621\u0645\u0629 \u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u0632\u0645\u0646 \u0627\u0644\u0645\u064a\u062a \u0644\u062d\u062c\u0645 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0645\u0639 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0623\u0632\u0645\u0646\u0629 \u0623\u0637\u0648\u0644 \u0623\u0648 \u0627\u0644\u0625\u0634\u0631\u0627\u0641 \u0639\u0644\u0649 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0644\u0644\u0622\u0644\u0627\u062a \u0627\u0644\u0623\u0643\u0628\u0631. \u0643\u0645\u0627 \u064a\u062c\u0628 \u0627\u062e\u062a\u0628\u0627\u0631 \u0641\u062d\u0635 \u062c\u0627\u0647\u0632\u064a\u0629 \u0627\u0644\u0642\u0627\u0637\u0639 \u0645\u0639 \u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0646\u0627\u0628\u0636 \u0644\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u062d\u0638\u0631 \u0623\u0648\u0627\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u0623\u062e\u064a\u0631\u0627\u064b\u060c \u064a\u062c\u0628 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0642\u0641\u0644 \u0628\u0639\u062f \u0628\u0644\u0648\u063a \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u0639\u062f\u062f \u0627\u0644\u0645\u062d\u0627\u0648\u0644\u0627\u062a\u060c \u0644\u0636\u0645\u0627\u0646 \u0627\u0634\u062a\u0631\u0627\u0637 \u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0636\u0628\u0637 \u0627\u0644\u064a\u062f\u0648\u064a \u0642\u0628\u0644 \u0623\u064a \u0645\u062d\u0627\u0648\u0644\u0629 \u0625\u063a\u0644\u0627\u0642 \u062a\u0644\u0642\u0627\u0626\u064a \u0623\u062e\u0631\u0649.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quick Takeaway Confirm the project duty and applicable requirements for VCB before selection or service work. Use recorded inspection and test evidence instead of unsupported assumptions. Keep the final acceptance, maintenance, and handover documents with the equipment record. Automatic reclosing has saved countless hours of unnecessary outage time on distribution feeders. A transient fault clears, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4163,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-4168","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/4168","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=4168"}],"version-history":[{"count":2,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/4168\/revisions"}],"predecessor-version":[{"id":4275,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/4168\/revisions\/4275"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/4163"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=4168"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=4168"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=4168"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}