{"id":4192,"date":"2026-08-11T09:00:00","date_gmt":"2026-08-11T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=4192"},"modified":"2026-08-18T14:59:30","modified_gmt":"2026-08-18T14:59:30","slug":"vcb-rfq-data-sheet-mandatory-control-circuit-and-interlocking-fields","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ar\/vcb-rfq-data-sheet-mandatory-control-circuit-and-interlocking-fields\/","title":{"rendered":"\u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u0644\u0640VCB: \u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629"},"content":{"rendered":"<h2>\u062e\u0644\u0627\u0635\u0629 \u0633\u0631\u064a\u0639\u0629<\/h2>\n<ul>\n<li>\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0648\u0638\u0631\u0648\u0641 \u062a\u0634\u063a\u064a\u0644 VCB \u0642\u0628\u0644 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0623\u0648 \u0625\u062c\u0631\u0627\u0621 \u0623\u0639\u0645\u0627\u0644 \u0627\u0644\u062e\u062f\u0645\u0629.<\/li>\n<li>\u0627\u0633\u062a\u0646\u062f \u0625\u0644\u0649 \u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0641\u062d\u0635 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u0627\u062a \u063a\u064a\u0631 \u0627\u0644\u0645\u062f\u0639\u0648\u0645\u0629.<\/li>\n<li>\u0627\u062d\u062a\u0641\u0638 \u0628\u0648\u062b\u0627\u0626\u0642 \u0627\u0644\u0642\u0628\u0648\u0644 \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0644\u062a\u0633\u0644\u064a\u0645 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0636\u0645\u0646 \u0633\u062c\u0644 \u0627\u0644\u0645\u0639\u062f\u0627\u062a.<\/li>\n<\/ul>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0644\u0627 \u062a\u062a\u0639\u0627\u0645\u0644 \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a \u0637\u0644\u0628 \u0639\u0631\u0636 \u0627\u0644\u0633\u0639\u0631 (RFQ) \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640VCB \u0645\u0639 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0639\u062a\u0628\u0627\u0631\u0647\u0627 \u0642\u0627\u0626\u0645\u0629 \u0639\u0627\u0645\u0629 \u0628\u0627\u0644\u0645\u0644\u062d\u0642\u0627\u062a. \u0641\u0641\u064a \u0642\u0648\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0641\u0631\u0627\u063a\u064a\u0629 \u0645\u062a\u0648\u0633\u0637\u0629 \u0627\u0644\u062c\u0647\u062f\u060c \u062a\u062d\u062f\u062f \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0641\u0635\u0644 \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0648\u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062d\u062c\u0628 \u0648\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0633\u062d\u0628 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0645\u0646 \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0642\u0627\u0637\u0639 \u064a\u0633\u062a\u0637\u064a\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0641\u062a\u062d \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u0633\u062d\u0628 \u0648\u0627\u0644\u0627\u0646\u062f\u0645\u0627\u062c \u0628\u0623\u0645\u0627\u0646 \u0645\u0639 \u0645\u0646\u0637\u0642 \u0627\u0644\u0644\u0648\u062d\u0629.<\/p>\n<p>\u0644\u0635\u064a\u0627\u063a\u0629 \u0645\u0648\u0627\u0635\u0641\u0629 \u0648\u0627\u0636\u062d\u0629 \u0644\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640VCB \u0641\u064a RFQ\u060c \u064a\u0646\u0628\u063a\u064a \u0644\u0644\u0645\u0634\u062a\u0631\u064a \u0623\u0646 \u064a\u0637\u0644\u0628 \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f\u064a\u0646 \u062a\u062d\u062f\u064a\u062f \u0643\u0644 \u062c\u0647\u0627\u0632 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0648\u0643\u0644 \u062a\u0644\u0627\u0645\u0633 \u0633\u0645\u0627\u062d \u0623\u0648 \u062d\u062c\u0628\u060c \u0648\u0643\u0644 \u0648\u0627\u062c\u0647\u0629 \u0628\u064a\u0646 \u0627\u0644\u0642\u0627\u0637\u0639 \u0648\u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0648\u0644\u0627 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0641\u062a\u0631\u0636 RFQ \u0623\u0646 \u062c\u0645\u064a\u0639 \u0639\u0644\u0627\u0645\u0627\u062a VCB \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u062a\u0633\u062a\u062e\u062f\u0645 \u0623\u0633\u0645\u0627\u0621 \u0623\u0637\u0631\u0627\u0641 \u0623\u0648 \u062a\u0631\u062a\u064a\u0628\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0645\u062a\u0637\u0627\u0628\u0642\u0629. \u0648\u062a\u0648\u0636\u062d \u0648\u062b\u0627\u0626\u0642 ABB \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0642\u0627\u0637\u0639\u064a VD4X \u0648SecoVac\u060c \u0648\u0625\u0631\u0634\u0627\u062f\u0627\u062a Schneider \u0644\u0644\u0645\u0633\u0627\u0639\u062f\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 EvoPacT\u060c \u0648\u0648\u062b\u0627\u0626\u0642 Siemens \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640VCB \u0623\u0646 \u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0645\u0648\u0632\u0639\u0629 \u0628\u064a\u0646 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0627\u062a \u0627\u0644\u0645\u0631\u0643\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u0627\u0637\u0639 \u0648\u0645\u0634\u063a\u0644\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0648\u0627\u0644\u0645\u062d\u0631\u0643\u0627\u062a \u0648\u062f\u0648\u0627\u0626\u0631 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u0627\u0644\u0623\u0642\u0641\u0627\u0644 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0648\u0648\u0627\u062c\u0647\u0627\u062a \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0633\u062d\u0628 \u0648\u0645\u0646\u0637\u0642 \u0627\u0644\u0645\u0648\u0636\u0639 \u0641\u064a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-rfq-data-sheet-mandatory-control-circuit-and-interlocking-fields-fig-01.webp\" alt=\"XBRELE \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u0644\u0640VCB: \u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629 - \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u0647\u0646\u062f\u0633\u064a\u0629\" \/><\/figure>\n<h3>\u062d\u0642\u0648\u0644 \u0627\u0644\u062a\u0639\u0631\u064a\u0641 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629 \u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645<\/h3>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u062c\u062f\u0648\u0644\u0627\u064b \u0645\u062e\u0635\u0635\u0627\u064b \u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a VCB. \u0648\u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0644\u060c \u064a\u062d\u062f\u062f \u0627\u0644\u0645\u0648\u0631\u062f \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0643\u0644 \u0639\u0646\u0635\u0631 \u0645\u0634\u0645\u0648\u0644\u0627\u064b\u060c \u0648\u0643\u064a\u0641\u064a\u0629 \u062a\u0639\u0631\u064a\u0641\u0647 \u0641\u064a \u0627\u0644\u0645\u062e\u0637\u0637\u060c \u0648\u0623\u064a\u0646 \u062a\u0646\u062a\u0647\u064a \u062a\u0648\u0635\u064a\u0644\u0627\u062a\u0647.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062d\u0642\u0644 RFQ<\/th>\n<th>\u0645\u0627 \u064a\u062c\u0628 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0627\u0644\u062a\u0635\u0631\u064a\u062d \u0628\u0647<\/th>\n<th>\u0644\u0645\u0627\u0630\u0627 \u0647\u0630\u0627 \u0645\u0647\u0645<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \/ \u0645\u0644\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u0631\u0645\u0632 \u0627\u0644\u062c\u0647\u0627\u0632 \u0648\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u0645\u0633\u0627\u0631 \u0623\u0645\u0631 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062d\u062c\u0628 \u0627\u0644\u0645\u062a\u0633\u0644\u0633\u0644\u0629<\/td>\n<td>\u062a\u062d\u062f\u062f \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0648SecoVac \u0645\u062d\u0631\u0631\u0627\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0628\u0648\u0635\u0641\u0647\u0627 \u0639\u0646\u0627\u0635\u0631 \u0623\u0633\u0627\u0633\u064a\u0629 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645.<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u062d\u0631\u0631 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a \/ \u0645\u0644\u0641 \u0627\u0644\u0641\u0635\u0644<\/td>\n<td>\u0627\u0644\u0639\u062f\u062f \u0648\u0631\u0645\u0648\u0632 \u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0648\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u0645\u0633\u0627\u0631 \u0623\u0645\u0631 \u0627\u0644\u0641\u0635\u0644<\/td>\n<td>\u064a\u0645\u064a\u0632 ABB VD4X \u0645\u062d\u0631\u0631\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0635\u0641 SecoVac \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0636\u0645\u0646 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645.<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0623\u0648 \u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/td>\n<td>\u0631\u0645\u0632 \u0627\u0644\u062c\u0647\u0627\u0632 \u0648\u0645\u0648\u0642\u0639\u0647 \u0627\u0644\u0645\u0646\u0637\u0642\u064a \u0648\u062a\u0641\u0627\u0639\u0644\u0647 \u0645\u0639 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u062a\u0634\u064a\u0631 \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0648SecoVac \u0625\u0644\u0649 \u0645\u0631\u062d\u0644\u0627\u062a \u0645\u0646\u0639 \u0627\u0644\u0636\u062e\u061b \u0648\u062a\u062d\u0630\u0631 Schneider \u0645\u0646 \u0623\u0646 \u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0642\u062f \u062a\u0639\u0637\u0644 \u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629.<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td>\n<td>\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0645\u062d\u0631\u0643 \u0648\u0645\u0633\u0627\u0631 \u0627\u0644\u062a\u063a\u0630\u064a\u0629 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0623\u0648 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0648\u0627\u062c\u0647\u0629 \u0628\u064a\u0627\u0646 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td>\n<td>\u062a\u062d\u062f\u062f \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0648SecoVac \u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0628\u0648\u0635\u0641\u0647 \u062c\u0632\u0621\u0627\u064b \u0645\u0646 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u0642\u0627\u0637\u0639.<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0622\u0644\u064a\u0629<\/td>\n<td>\u0639\u062f\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0648\u062d\u0627\u0644\u062a\u0647\u0627 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0648\u0648\u0638\u064a\u0641\u062a\u0647\u0627 \u0648\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0623\u0637\u0631\u0627\u0641<\/td>\n<td>\u064a\u0645\u064a\u0632 ABB VD4X \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0622\u0644\u064a\u0629\u061b \u0648\u062a\u0634\u064a\u0631 SecoVac \u0625\u0644\u0649 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52.<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0627\u0644\u062d\u062c\u0628<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0648\u0645\u0648\u0636\u0639\u0647\u0627 \u0641\u064a \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0648\u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u064a \u062a\u062a\u062d\u0643\u0645 \u0628\u0647\u0627<\/td>\n<td>\u064a\u0645\u064a\u0632 ABB VD4X \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0627\u0644\u062d\u062c\u0628 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u0642\u0627\u0637\u0639.<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0648\u0631\u062f\u0629 \u0648\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0648\u062a\u0641\u0627\u0639\u0644\u0647\u0627 \u0645\u0639 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0641\u062a\u062d \u0627\u0644\u0645\u062d\u0644\u064a\u0629<\/td>\n<td>\u064a\u0639\u0631\u0641 ABB VD4X \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0628\u0634\u0643\u0644 \u0645\u0646\u0641\u0635\u0644 \u0639\u0646 \u063a\u064a\u0631\u0647\u0627 \u0645\u0646 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629.<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u0631\u0645\u0632 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0638\u0631\u0648\u0641 \u062a\u0634\u063a\u064a\u0644\u0647 \u0648\u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u064a\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td>\n<td>\u062a\u0635\u0641 ABB SecoVac \u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0644\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643.<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0633\u062d\u0628 \u0623\u0648 \u0645\u0648\u0636\u0639 \u0627\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u0642\u0627\u0628\u0644 \u0644\u0644\u0633\u062d\u0628<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0623\u0648 \u0648\u0627\u062c\u0647\u0627\u062a \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0645\u0648\u0627\u0636\u0639 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\/\u0627\u0644\u062e\u062f\u0645\u0629\/\u0627\u0644\u0641\u0635\u0644<\/td>\n<td>\u062a\u0635\u0641 ABB SecoVac \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629 \u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629 \u0648\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0641\u0635\u0644 \u0625\u064a\u062c\u0627\u0628\u064a\u0629 \u0648\u0633\u0644\u0628\u064a\u0629 \u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0627\u0644\u0633\u062d\u0628.<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<td>\u0648\u0627\u062c\u0647\u0629 \u062a\u0634\u0627\u0628\u0643 \u0645\u0639 \u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u062a\u0623\u0631\u064a\u0636 \u0623\u0648 \u0644\u0648\u062d\u0629<\/td>\n<td>\u062a\u0648\u062b\u0642 Siemens \u062a\u0634\u0627\u0628\u0643 VCB \u0639\u0628\u0631 \u0622\u0644\u064a\u0627\u062a \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0641\u064a \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 RFQ \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u0641\u0639\u0644\u064a \u0644\u0644\u0645\u0648\u0631\u062f \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0627\u0643\u062a\u0641\u0627\u0621 \u0628\u0639\u0628\u0627\u0631\u0629 \u0641\u064a \u0627\u0644\u0643\u062a\u064a\u0628 \u0645\u062b\u0644 \u00ab\u062f\u0627\u0626\u0631\u0629 \u062a\u062d\u0643\u0645 \u0642\u064a\u0627\u0633\u064a\u0629\u00bb. \u0643\u0645\u0627 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 \u0648\u0631\u0642\u0629 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0631\u0643\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u0627\u0637\u0639 \u0648\u062a\u0644\u0643 \u0627\u0644\u0645\u0631\u0643\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>\n<h3>\u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u064a RFQ<\/h3>\n<p>\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0647\u064a \u0627\u0644\u062c\u0632\u0621 \u0645\u0646 \u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a VCB \u0627\u0644\u0630\u064a \u064a\u0624\u062f\u064a \u0641\u064a\u0647 \u063a\u0645\u0648\u0636 RFQ \u063a\u0627\u0644\u0628\u0627\u064b \u0625\u0644\u0649 \u0645\u062e\u0627\u0637\u0631 \u0627\u0644\u0634\u0631\u0627\u0621. \u062a\u0635\u0641 \u0648\u062b\u0627\u0626\u0642 ABB SecoVac \u062f\u0627\u0626\u0631\u0629 \u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u0634\u0627\u0628\u0643 \u062a\u0636\u0645 \u0645\u0644\u0641 \u0625\u063a\u0644\u0627\u0642 \u0648\u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52 \u0648\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0648\u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0648\u0645\u0643\u0648\u0646\u0627\u062a \u062d\u062c\u0628 \u0648\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629. \u0643\u0645\u0627 \u062a\u0645\u064a\u0632 \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0627\u0644\u062d\u062c\u0628 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0648\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0648\u0645\u062d\u0631\u0631\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a\u0629 \u0648\u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e. \u0631\u0627\u062c\u0639 <a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker\/\">\u062e\u064a\u0627\u0631\u0627\u062a \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0645\u0641\u0631\u063a<\/a> \u0643\u0646\u0642\u0637\u0629 \u0628\u062f\u0627\u064a\u0629 \u0639\u0645\u0644\u064a\u0629 \u0644\u0645\u0637\u0627\u0628\u0642\u0629 \u0635\u064a\u063a\u0629 \u0627\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629 \u0645\u0639 \u0627\u0644\u062a\u0637\u0628\u064a\u0642.<\/p>\n<p>\u0644\u0630\u0644\u0643 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u062a\u0636\u0645\u0646 RFQ \u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u062a\u0627\u0644\u064a\u0629:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062d\u0642\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/th>\n<th>\u0627\u0644\u0625\u062f\u062e\u0627\u0644 \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0641\u064a RFQ<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0645\u0635\u062f\u0631 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td>\n<td>\u0645\u062d\u0644\u064a \u0623\u0648 \u0639\u0646 \u0628\u064f\u0639\u062f \u0623\u0648 \u0643\u0644\u0627\u0647\u0645\u0627\u060c \u062d\u0633\u0628 \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639<\/td>\n<\/tr>\n<tr>\n<td>\u0631\u0645\u0632 \u0645\u062d\u0631\u0631 \/ \u0645\u0644\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u0631\u0645\u0632 \u0627\u0644\u062c\u0647\u0627\u0632 \u0627\u0644\u062f\u0642\u064a\u0642 \u0644\u062f\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0648\u0645\u0631\u062c\u0639 \u0627\u0644\u0645\u062e\u0637\u0637<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u0627\u0631 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u062c\u0645\u064a\u0639 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u062a\u0633\u0644\u0633\u0644\u0629 \u0645\u0639 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0628\u0645\u0627 \u0641\u064a\u0647\u0627 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0633\u0645\u0627\u062d \u0648\u0627\u0644\u062d\u062c\u0628<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u0627\u0632 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/td>\n<td>\u0648\u0638\u064a\u0641\u0629 \u0642\u0627\u0626\u0645\u0629 \u0639\u0644\u0649 \u0645\u0631\u062d\u0644 \u0623\u0648 \u0622\u0644\u064a\u0629\u060c \u0645\u0639 \u0645\u0648\u0642\u0639\u0647\u0627 \u0641\u064a \u0627\u0644\u0645\u062e\u0637\u0637<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0634\u0645\u0648\u0644\u0629 \u0648\u0638\u0631\u0648\u0641 \u062a\u0634\u063a\u064a\u0644\u0647\u0627<\/td>\n<\/tr>\n<tr>\n<td>\u0633\u0645\u0627\u062d \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u064a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0632\u0646\u0629 \u0623\u0648 \u0645\u0624\u0634\u0631 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0641\u0627\u0639\u0644 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f<\/td>\n<td>\u062a\u0648\u0636\u064a\u062d \u0643\u064a\u0641\u064a\u0629 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52 \u0623\u0648 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0622\u0644\u064a\u0629 \u0641\u064a \u0645\u0633\u0627\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0645\u062d\u0644\u064a\u0629 \u0645\u0634\u0645\u0648\u0644\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0627\u062c\u0647\u0629 \u0627\u0644\u0645\u062d\u0637\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629<\/td>\n<td>\u0623\u0631\u0642\u0627\u0645 \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0644\u062a\u0648\u0635\u064a\u0644 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0645\u0646 \u0627\u0644\u0639\u0645\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0631\u0633\u0648\u0645\u0627\u062a \u0627\u0644\u0645\u0648\u0631\u062f<\/td>\n<td>\u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u0639\u0646\u0635\u0631\u064a \u0627\u0644\u0643\u0627\u0645\u0644 \u0648\u0645\u062e\u0637\u0637 \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0645\u0639 \u0627\u0644\u0639\u0631\u0636<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0644\u0627 \u062a\u062d\u062f\u062f \u0648\u0631\u0642\u0629 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0628\u0646\u064a\u0629 \u062f\u0627\u0626\u0631\u0629 \u063a\u064a\u0631 \u0645\u0648\u062b\u0642\u0629. \u0628\u0644 \u064a\u062c\u0628 \u0623\u0646 \u062a\u0637\u0644\u0628 \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f \u0625\u0638\u0647\u0627\u0631 \u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0648\u062a\u062d\u062f\u064a\u062f \u0643\u0644 \u0639\u0646\u0635\u0631 \u0633\u0645\u0627\u062d \u0623\u0648 \u062d\u062c\u0628.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-rfq-data-sheet-mandatory-control-circuit-and-interlocking-fields-fig-02.webp\" alt=\"XBRELE \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u0644\u0640VCB: \u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629 - \u0642\u064a\u0627\u0633 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\" \/><\/figure>\n<h3>\u0642\u0648\u0627\u0639\u062f \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629<\/h3>\n<p>\u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0644\u064a\u0633 \u0645\u062c\u0631\u062f \u0627\u0633\u0645 \u0645\u0631\u062d\u0644 \u0641\u064a \u0642\u0627\u0626\u0645\u0629 \u0642\u0637\u0639. \u0628\u0644 \u0647\u0648 \u0645\u062a\u0637\u0644\u0628 \u0648\u0638\u064a\u0641\u064a \u0644\u0645\u0646\u0639 \u0645\u062d\u0627\u0648\u0644\u0627\u062a \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629 \u0639\u0646\u062f \u0627\u0633\u062a\u0645\u0631\u0627\u0631 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0628\u0639\u062f \u0627\u0644\u0641\u0635\u0644 \u0623\u0648 \u0641\u0634\u0644 \u062a\u0633\u0644\u0633\u0644 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u062a\u0634\u064a\u0631 \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0648SecoVac \u0625\u0644\u0649 \u0645\u0631\u062d\u0644\u0627\u062a \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u0642\u0627\u0637\u0639\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0636\u064a\u0641 \u0625\u0631\u0634\u0627\u062f\u0627\u062a Schneider \u062a\u0646\u0628\u064a\u0647\u0627\u064b \u0645\u0647\u0645\u0627\u064b \u0628\u0634\u0623\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644: \u064a\u062c\u0628 \u0623\u0644\u0627 \u062a\u0648\u0635\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0642\u0627\u0637\u0639 \u0639\u0644\u0649 \u0627\u0644\u062a\u0648\u0627\u0644\u064a \u0645\u0639 \u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0628\u0637\u0631\u064a\u0642\u0629 \u062a\u0639\u0637\u0644 \u0646\u0638\u0627\u0645 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a. \u0648\u062a\u0645\u064a\u0632 Schneider \u0647\u0630\u0627 \u0627\u0644\u062a\u0631\u062a\u064a\u0628 \u063a\u064a\u0631 \u0627\u0644\u0622\u0645\u0646 \u0639\u0646 \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0639\u0628\u0631 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0642\u0648\u0627\u0637\u0639 \u0623\u062e\u0631\u0649. \u0625\u0646 <a href=\"https:\/\/xbrele.com\/ar\/vacuum-circuit-breaker-ratings\/\">\u062f\u0644\u064a\u0644 \u062a\u0635\u0646\u064a\u0641\u0627\u062a VCB \u0648\u0627\u062e\u062a\u064a\u0627\u0631\u0647<\/a> \u0639\u0644\u0649 \u062a\u062d\u0648\u064a\u0644 \u0648\u0627\u062c\u0628 \u0627\u0644\u0646\u0638\u0627\u0645 \u0625\u0644\u0649 \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u0648\u0627\u062c\u0628 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646\u0647\u0627.<\/p>\n<p>\u0644\u0630\u0644\u0643 \u064a\u0646\u0628\u063a\u064a \u0644\u0644\u0645\u0634\u062a\u0631\u064a \u0625\u062f\u0631\u0627\u062c \u062a\u0635\u0631\u064a\u062d \u0645\u062d\u062f\u062f \u0628\u0634\u0623\u0646 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0641\u064a RFQ \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0641\u062a\u0631\u0627\u0636 \u0623\u0646\u0647 \u0642\u064a\u0627\u0633\u064a.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062d\u0642\u0644 RFQ \u0644\u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/th>\n<th>\u0627\u0644\u062a\u0635\u0631\u064a\u062d \u0627\u0644\u0645\u0637\u0644\u0648\u0628<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0637\u0631\u064a\u0642\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u0631\u062d\u0644 \u0623\u0648 \u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0622\u0644\u064a\u0629 \u0623\u0648 \u0627\u0644\u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u0645\u0631\u0643\u0628 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0648\u0636\u0639 \u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0641\u064a \u0627\u0644\u0645\u062e\u0637\u0637<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0625\u0638\u0647\u0627\u0631 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0641\u064a \u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u062d\u0643\u0645<\/td>\n<\/tr>\n<tr>\n<td>\u0633\u0644\u0648\u0643 \u0623\u0645\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0648\u0635\u0641 \u0643\u064a\u0641\u064a\u0629 \u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u062a\u0643\u0631\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0642\u064a\u062f \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0642\u0627\u0637\u0639<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0623\u0643\u064a\u062f \u0623\u0646 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0642\u0627\u0637\u0639 \u0644\u0627 \u062a\u0633\u062a\u062e\u062f\u0645 \u0628\u0637\u0631\u064a\u0642\u0629 \u062a\u0639\u0637\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0645\u0639 \u0642\u0627\u0637\u0639 \u0622\u062e\u0631<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0623\u064a \u062a\u0634\u0627\u0628\u0643 \u0639\u0628\u0631 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0642\u0648\u0627\u0637\u0639 \u0623\u062e\u0631\u0649 \u0625\u0630\u0627 \u0637\u0644\u0628\u0647 \u0627\u0644\u0645\u0634\u0631\u0648\u0639<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0631\u062c\u0639 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0636\u0645\u064a\u0646 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0641\u064a \u0625\u062c\u0631\u0627\u0621 FAT \u0623\u0648 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0648\u0638\u064a\u0641\u064a \u0639\u0646\u062f \u0627\u0644\u0637\u0644\u0628<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0647\u0630\u0627 \u062d\u0642\u0644 \u0625\u0644\u0632\u0627\u0645\u064a \u0644\u062a\u0634\u0627\u0628\u0643 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a RFQ \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640VCB\u060c \u0644\u0623\u0646 \u0625\u062f\u0631\u0627\u062c \u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0631\u0633\u0645\u064a\u0627\u064b \u0644\u0627 \u064a\u062b\u0628\u062a \u0628\u062d\u062f \u0630\u0627\u062a\u0647 \u0623\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u062a\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0648\u0643 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0627\u0644\u0645\u0642\u0635\u0648\u062f.<\/p>\n<h3>\u062d\u0642\u0648\u0644 \u0627\u0644\u0641\u0635\u0644 \u0648\u0645\u062d\u0631\u0631 \u0627\u0644\u0641\u0635\u0644 \u0648\u0627\u0644\u0633\u062d\u0628<\/h3>\n<p>\u064a\u0646\u0628\u063a\u064a \u062a\u0648\u062b\u064a\u0642 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0641\u0635\u0644 \u0628\u0634\u0643\u0644 \u0645\u0646\u0641\u0635\u0644 \u0639\u0646 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u062a\u0645\u064a\u0632 \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0645\u062d\u0631\u0631\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0635\u0641 \u0648\u062b\u0627\u0626\u0642 ABB SecoVac \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0627\u0644\u0642\u0627\u0637\u0639. \u0643\u0645\u0627 \u062a\u0635\u0641 SecoVac \u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0641\u0635\u0644 \u0625\u064a\u062c\u0627\u0628\u064a\u0629 \u0648\u0633\u0644\u0628\u064a\u0629 \u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0627\u0644\u0633\u062d\u0628\u061b \u0644\u0630\u0644\u0643 \u0644\u0627 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u062a\u0639\u0627\u0645\u0644 RFQ \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640VCB \u0627\u0644\u0642\u0627\u0628\u0644 \u0644\u0644\u0633\u062d\u0628 \u0645\u0639 \u0627\u0644\u0633\u062d\u0628 \u0628\u0627\u0639\u062a\u0628\u0627\u0631\u0647 \u0645\u064a\u0632\u0629 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0644\u0644\u0648\u062d\u0629 \u0641\u062d\u0633\u0628.<\/p>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 RFQ \u0627\u0644\u062d\u0642\u0648\u0644 \u0627\u0644\u062a\u0627\u0644\u064a\u0629:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062d\u0642\u0644 \u0627\u0644\u0641\u0635\u0644 \u0648\u0627\u0644\u0633\u062d\u0628<\/th>\n<th>\u0627\u0644\u0625\u062f\u062e\u0627\u0644 \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0641\u064a RFQ<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0639\u062f\u062f \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0627\u0644\u0639\u062f\u062f \u0648\u0631\u0645\u0648\u0632 \u0627\u0644\u0623\u062c\u0647\u0632\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0631\u0627\u062c\u0639 \u0623\u0637\u0631\u0627\u0641 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0642\u062f\u064a\u0645 \u0623\u0631\u0642\u0627\u0645 \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0645\u062e\u0637\u0637\u0627\u062a<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0639\u0631\u064a\u0641 \u0645\u062d\u0631\u0631 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a\u0629 \u062d\u064a\u062b\u0645\u0627 \u064a\u0646\u0637\u0628\u0642<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0635\u0627\u062f\u0631 \u0623\u0648\u0627\u0645\u0631 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<td>\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u0623\u0648\u0627\u0645\u0631 \u0627\u0644\u0645\u062d\u0644\u064a\u0629 \u0623\u0648 \u0639\u0646 \u0628\u0639\u062f \u0623\u0648 \u0645\u0646 \u0645\u0631\u062d\u0644 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0623\u0648 \u0627\u0644\u0645\u062d\u062f\u062f\u0629 \u0644\u0644\u0645\u0634\u0631\u0648\u0639<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0645\u0631\u062a\u0628\u0637 \u0628\u0627\u0644\u0633\u062d\u0628<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0625\u064a\u062c\u0627\u0628\u064a\u0629 \u0623\u0648 \u0627\u0644\u0633\u0644\u0628\u064a\u0629 \u0645\u0634\u0645\u0648\u0644\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0643\u0648\u0646\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062d\u062c\u0628 \u0623\u0648 \u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629 \u0625\u0646 \u0648\u062c\u062f\u062a<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0627\u0639\u062a\u0645\u0627\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0636\u0639<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0633\u0645\u0627\u062d\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0623\u0648 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0645\u0648\u0636\u0639 \u0627\u0644\u062e\u062f\u0645\u0629 \u0623\u0648 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0623\u0648 \u0627\u0644\u0641\u0635\u0644<\/td>\n<\/tr>\n<tr>\n<td>\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0636\u0645\u064a\u0646 \u0641\u062d\u0648\u0635 \u0648\u0638\u064a\u0641\u064a\u0629 \u0644\u0633\u0644\u0648\u0643 \u0627\u0644\u0641\u0635\u0644 \u0648\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0633\u062d\u0628 \u0639\u0646\u062f \u0627\u0644\u0637\u0644\u0628<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0644\u0627 \u062a\u0641\u0631\u0636 RFQ \u0623\u0639\u062f\u0627\u062f \u0645\u0644\u0641\u0627\u062a \u0641\u0635\u0644 \u0623\u0648 \u0623\u0631\u0642\u0627\u0645 \u0623\u0637\u0631\u0627\u0641 \u063a\u064a\u0631 \u0645\u062a\u062d\u0642\u0642 \u0645\u0646\u0647\u0627. \u0628\u0644 \u064a\u062c\u0628 \u0623\u0646 \u062a\u0637\u0644\u0628 \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f \u0627\u0644\u062a\u0635\u0631\u064a\u062d \u0628\u0647\u0627 \u0648\u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0645\u062e\u0637\u0637\u0627\u062a \u0627\u0644\u0639\u0646\u0635\u0631\u064a\u0629 \u0648\u0645\u062e\u0637\u0637\u0627\u062a \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0641\u0639\u0644\u064a\u0629.<\/p>\n<h3>\u062d\u0642\u0648\u0644 \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0648\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/h3>\n<p>\u062a\u0635\u0641 \u0648\u062b\u0627\u0626\u0642 Siemens \u0627\u0644\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0641\u064a VCB\u060c \u0628\u0645\u0627 \u0641\u064a\u0647\u0627 \u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0645\u0646 \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0628\u0631 \u0622\u0644\u064a\u0627\u062a \u0627\u0644\u0642\u0641\u0644 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0648\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0648\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0645\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0636\u0639. \u0648\u0647\u0630\u0647 \u0627\u0644\u0623\u062f\u0644\u0629 \u0645\u0647\u0645\u0629 \u0644\u0623\u0646 RFQ \u0627\u0644\u062a\u064a \u062a\u0637\u0644\u0628 \u0641\u0642\u0637 \u00ab\u062a\u0634\u0627\u0628\u0643 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0634\u0645\u0648\u0644\u00bb \u0642\u062f \u062a\u063a\u0641\u0644 \u0627\u0644\u062d\u062f\u0648\u062f \u0628\u064a\u0646 VCB \u0648\u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u0648\u0644\u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0634\u0647\u0648\u062f \u0648\u0627\u0644\u0633\u062c\u0644\u0627\u062a\u060c \u0637\u0627\u0628\u0642 \u0627\u0644\u0623\u062f\u0644\u0629 \u0645\u0639 <a href=\"https:\/\/xbrele.com\/ar\/vcb-fat-sat-acceptance-test-checklist\/\">\u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u0635\u0646\u0639\u064a \u0648\u0627\u0644\u0645\u0648\u0642\u0639\u064a \u0644\u0640 VCB<\/a>.<\/p>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0642\u0633\u0645 \u0648\u0631\u0642\u0629 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0625\u0644\u0649 \u0648\u0638\u0627\u0626\u0641 \u0645\u0631\u0643\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u0627\u0637\u0639 \u0623\u0648 \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0641\u0626\u0629 \u0627\u0644\u062a\u0634\u0627\u0628\u0643<\/th>\n<th>\u062d\u0642\u0648\u0644 RFQ \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0645\u0631\u0643\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u0627\u0637\u0639<\/td>\n<td>\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u0627\u062a \u0627\u0644\u062d\u062c\u0628 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0631\u0643\u0628\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u0627\u0637\u0639<\/td>\n<td>\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0623\u0648 \u062d\u062c\u0628 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0645\u062d\u0644\u064a\u0629 \u0623\u0648 \u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0642\u0641\u0644 \u0627\u0644\u0642\u0627\u0626\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0622\u0644\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0633\u062d\u0628<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0648\u0636\u0639 \u0648\u0645\u0643\u0648\u0646\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629 \u0648\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0627\u0644\u0633\u062d\u0628<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<td>\u0648\u0627\u062c\u0647\u0627\u062a \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0623\u0648 \u0628\u0627\u0628 \u0627\u0644\u0644\u0648\u062d\u0629 \u0623\u0648 \u0627\u0644\u0642\u0641\u0644 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0639\u0646\u062f \u0627\u0644\u062d\u0627\u062c\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0636\u0639<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0627\u0644\u0645\u0648\u0627\u0636\u0639 \u0627\u0644\u062a\u064a \u062a\u0633\u0645\u062d \u0628\u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0648\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0623\u0648 \u062a\u0645\u0646\u0639\u0647<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u0624\u0648\u0644\u064a\u0629 \u0627\u0644\u0623\u0637\u0631\u0627\u0641<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0646\u062a\u0647\u064a \u0639\u0646\u062f \u0645\u062c\u0645\u0648\u0639\u0629 \u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0642\u0627\u0637\u0639 \u0623\u0648 \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u0624\u0648\u0644\u064a\u0629 \u0627\u0644\u062a\u0646\u0633\u064a\u0642<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0645\u0636\u0645\u0646\u0629 \u0636\u0645\u0646 \u062a\u0648\u0631\u064a\u062f VCB \u0648\u062a\u0644\u0643 \u0627\u0644\u062a\u064a \u064a\u0648\u0641\u0631\u0647\u0627 \u0645\u0635\u0646\u0639 \u0627\u0644\u0644\u0648\u062d\u0629<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0644\u0634\u0631\u0627\u0621 VCB\u060c \u064a\u062a\u0645\u062b\u0644 \u0627\u0644\u0646\u0647\u062c \u0627\u0644\u0623\u0643\u062b\u0631 \u0623\u0645\u0627\u0646\u0627\u064b \u0641\u064a \u0637\u0644\u0628 \u0645\u0635\u0641\u0648\u0641\u0629 \u062a\u0634\u0627\u0628\u0643 \u0645\u0643\u062a\u0645\u0644\u0629. \u0648\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0635\u0646\u064a\u0641 \u0643\u0644 \u062d\u0627\u0644\u0629 \u0639\u0644\u0649 \u0623\u0646\u0647\u0627 \u0633\u0645\u0627\u062d \u0628\u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u062d\u062c\u0628 \u0644\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u0628\u062f\u0621 \u0641\u0635\u0644 \u0623\u0648 \u0628\u064a\u0627\u0646 \u0641\u0642\u0637 \u0623\u0648 \u063a\u064a\u0631 \u0645\u0646\u0637\u0628\u0642.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-rfq-data-sheet-mandatory-control-circuit-and-interlocking-fields-fig-03.webp\" alt=\"XBRELE \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u0644\u0640VCB: \u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629 - \u0633\u064a\u0627\u0642 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\" \/><\/figure>\n<h3>\u062d\u0642\u0648\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0648\u0627\u0644\u0628\u064a\u0627\u0646<\/h3>\n<p>\u0644\u0627 \u064a\u0645\u0643\u0646 \u0627\u0639\u062a\u0628\u0627\u0631 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0628\u0627\u062f\u0644 \u0645\u0627 \u0644\u0645 \u062a\u064f\u062d\u062f\u062f \u0648\u0638\u064a\u0641\u062a\u0647\u0627 \u0648\u062d\u0627\u0644\u062a\u0647\u0627 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0648\u062a\u0648\u0642\u064a\u062a\u0647\u0627. \u062a\u0645\u064a\u0632 \u0648\u062b\u0627\u0626\u0642 ABB VD4X \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0622\u0644\u064a\u0629 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0627\u0644\u062d\u062c\u0628 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629. \u0648\u062a\u0634\u064a\u0631 \u0648\u062b\u0627\u0626\u0642 ABB SecoVac \u0625\u0644\u0649 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52. \u0643\u0645\u0627 \u062a\u0628\u0631\u0632 \u0625\u0631\u0634\u0627\u062f\u0627\u062a Schneider \u0636\u0631\u0648\u0631\u0629 \u0627\u0644\u062a\u0639\u0627\u0645\u0644 \u0628\u0639\u0646\u0627\u064a\u0629 \u0645\u0639 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0642\u0627\u0637\u0639 \u0639\u0646\u062f \u0627\u0633\u062a\u062e\u062f\u0627\u0645\u0647\u0627 \u0642\u0631\u0628 \u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0625\u0646 <a href=\"https:\/\/library.e.abb.com\/public\/d5e3e8161c0a485a8992aa856c99a2aa\/VD4X_Instruction%20maual_EN_1YHA000081_REV%20A%202019.12.pdf\" target=\"_blank\" rel=\"noopener\">\u062f\u0644\u064a\u0644 \u062a\u0639\u0644\u064a\u0645\u0627\u062a ABB VD4X<\/a> \u0628\u0648\u0635\u0641\u0647 \u0627\u0644\u0645\u0635\u062f\u0631 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u0644\u0644\u0645\u062a\u0637\u0644\u0628 \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0645\u0646\u062a\u062c \u0627\u0644\u0645\u0630\u0643\u0648\u0631 \u0647\u0646\u0627.<\/p>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 RFQ \u062c\u062f\u0648\u0644 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u064a\u062a\u0636\u0645\u0646 \u0627\u0644\u062d\u0642\u0648\u0644 \u0627\u0644\u062a\u0627\u0644\u064a\u0629:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062d\u0642\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0645\u0633\u0627\u0639\u062f<\/th>\n<th>\u0627\u0644\u0625\u062f\u062e\u0627\u0644 \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0641\u064a RFQ<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0647\u0648\u064a\u0629 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/td>\n<td>\u0631\u0645\u0632 \u0627\u0644\u0645\u0648\u0631\u062f\u060c \u0645\u062b\u0644 \u0645\u0633\u0627\u0639\u062f \u0627\u0644\u0622\u0644\u064a\u0629 \u0623\u0648 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52 \u0623\u0648 \u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u062d\u062c\u0628 \u0623\u0648 \u062a\u0644\u0627\u0645\u0633 \u062a\u0634\u0627\u0628\u0643 \u0632\u0631 \u0627\u0644\u0636\u063a\u0637<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0648\u0638\u064a\u0641\u0629<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0623\u0648 \u0633\u0645\u0627\u062d \u0623\u0648 \u062d\u062c\u0628 \u0623\u0648 \u0648\u0638\u064a\u0641\u0629 \u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0623\u0648 \u0627\u0644\u062a\u0634\u0627\u0628\u0643<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0639\u0631\u064a\u0641 \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062d\u0627\u0644\u0629 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0625\u0644\u0649 \u0627\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u0645\u0641\u062a\u0648\u062d\/\u0627\u0644\u0645\u063a\u0644\u0642\u060c \u0648\u0645\u0648\u0636\u0639 \u0627\u0644\u0639\u0631\u0628\u0629 \u0639\u0646\u062f \u0627\u0644\u0627\u0642\u062a\u0636\u0627\u0621<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0643\u0645\u064a\u0629 \u0627\u0644\u0645\u062a\u0627\u062d\u0629<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0639\u062f\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a\u0629 \u0648\u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0648\u0636\u0639 \u0627\u0644\u062a\u0644\u0627\u0645\u0633<\/td>\n<td>\u0627\u0644\u0642\u0627\u0637\u0639 \u0623\u0648 \u0627\u0644\u0622\u0644\u064a\u0629 \u0623\u0648 \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u062c\u0647\u0629 \u0627\u0644\u062a\u0648\u0635\u064a\u0644<\/td>\n<td>\u062f\u0627\u0626\u0631\u0629 \u062f\u0627\u062e\u0644\u064a\u0629 \u0623\u0648 \u0637\u0631\u0641 \u0627\u0644\u0639\u0645\u064a\u0644 \u0623\u0648 \u0648\u0627\u062c\u0647\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0642\u064a\u0648\u062f<\/td>\n<td>\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0623\u064a \u0642\u064a\u0648\u062f \u0639\u0644\u0649 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0631\u062c\u0639 \u0627\u0644\u0631\u0633\u0645<\/td>\n<td>\u0645\u0631\u062c\u0639 \u062e\u0637 \u0627\u0644\u0645\u062e\u0637\u0637 \u0648\u0627\u0644\u0637\u0631\u0641 \u0628\u062f\u0642\u0629<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u064a\u0646\u0628\u063a\u064a \u0623\u0644\u0627 \u062a\u0643\u062a\u0641\u064a RFQ \u0628\u0637\u0644\u0628 \u00ab\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0633\u0627\u0639\u062f\u0629 NO\/NC\u00bb. \u0628\u0644 \u064a\u062c\u0628 \u0623\u0646 \u062a\u0637\u0644\u0628 \u062a\u062d\u062f\u064a\u062f \u0648\u0638\u064a\u0641\u0629 \u0643\u0644 \u062a\u0644\u0627\u0645\u0633 \u0643\u064a \u0644\u0627 \u064a\u064f\u0633\u0627\u0621 \u0641\u0647\u0645 \u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u062b\u0646\u0627\u0621 \u0647\u0646\u062f\u0633\u0629 \u0627\u0644\u0644\u0648\u062d\u0629.<\/p>\n<h3>\u062c\u062f\u0648\u0644 \u0645\u0642\u062a\u0631\u062d \u0644\u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ<\/h3>\n<p>\u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062c\u0645\u0639 \u062c\u062f\u0648\u0644 RFQ \u0639\u0645\u0644\u064a \u0627\u0644\u062d\u0642\u0648\u0644 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629 \u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0641\u064a \u062c\u062f\u0648\u0644 \u0648\u0627\u062d\u062f \u064a\u0633\u062a\u0643\u0645\u0644\u0647 \u0627\u0644\u0645\u0648\u0631\u062f. \u0648\u064a\u0645\u0643\u0646 \u0644\u0644\u0645\u0634\u062a\u0631\u064a \u0625\u0635\u062f\u0627\u0631 \u0627\u0644\u062c\u062f\u0648\u0644 \u0645\u0639 \u062e\u0627\u0646\u0627\u062a \u00ab\u064a\u0633\u062a\u0643\u0645\u0644\u0647\u0627 \u0627\u0644\u0645\u0648\u0631\u062f\u00bb \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0625\u062f\u062e\u0627\u0644 \u0642\u064a\u0645 \u0645\u0641\u062a\u0631\u0636\u0629.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0644\u0627.<\/th>\n<th>\u062d\u0642\u0644 \u0648\u0631\u0642\u0629 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a<\/th>\n<th>\u0627\u0644\u0631\u062f \u0627\u0644\u0645\u0637\u0644\u0648\u0628 \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u0645\u062e\u0637\u0637 \u062a\u062d\u0643\u0645 VCB<\/td>\n<td>\u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u0639\u0646\u0635\u0631\u064a \u0627\u0644\u0643\u0627\u0645\u0644<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u0645\u062e\u0637\u0637 \u0627\u0644\u0623\u0637\u0631\u0627\u0641<\/td>\n<td>\u062a\u0642\u062f\u064a\u0645 \u0645\u0631\u0627\u062c\u0639 \u0623\u0637\u0631\u0627\u0641 \u0627\u0644\u0639\u0645\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \/ \u0645\u0644\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0631\u0645\u0632 \u0648\u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u0645\u0633\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u0645\u062d\u0631\u0631 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a \/ \u0645\u0644\u0641 \u0627\u0644\u0641\u0635\u0644<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0631\u0645\u0632 \u0648\u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u0623\u0648\u0627\u0645\u0631<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u0645\u0631\u062d\u0644 \u0623\u0648 \u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0648\u0645\u0648\u0642\u0639\u0647\u0627 \u0641\u064a \u0627\u0644\u0645\u062e\u0637\u0637<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0622\u0644\u064a\u0629<\/td>\n<td>\u062a\u0642\u062f\u064a\u0645 \u062c\u062f\u0648\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0648\u0648\u0638\u0627\u0626\u0641\u0647\u0627<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>\u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0641\u064a \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0641\u0635\u0644 \u0623\u0648 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u0627\u0644\u0628\u064a\u0627\u0646 \u0623\u0648 \u0627\u0644\u062a\u0634\u0627\u0628\u0643<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0627\u0644\u062d\u062c\u0628<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0634\u0645\u0648\u0644\u0629 \u0648\u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u064a \u062a\u062d\u062c\u0628\u0647\u0627<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0634\u0645\u0648\u0644\u0629 \u0648\u0643\u064a\u0641 \u062a\u0624\u062b\u0631 \u0641\u064a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u0644\u064a<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u062d\u0627\u0644\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0645\u0648\u0636\u0639\u0647 \u0641\u064a \u0627\u0644\u062f\u0627\u0626\u0631\u0629<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>\u062a\u0644\u0627\u0645\u0633 \u0645\u0633\u0627\u0639\u062f \u062e\u0627\u0635 \u0628\u0627\u0644\u0642\u0627\u0637\u0639 \u0636\u0645\u0646 \u0645\u0633\u0627\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642<\/td>\n<td>\u062a\u0623\u0643\u064a\u062f \u0623\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0644\u0627 \u064a\u0639\u0637\u0644 \u0633\u0644\u0648\u0643 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>\u062a\u0634\u0627\u0628\u0643 \u0645\u0639 \u062a\u0644\u0627\u0645\u0633 \u0645\u0633\u0627\u0639\u062f \u0644\u0642\u0627\u0637\u0639 \u0622\u062e\u0631<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u064a\u062a\u0637\u0644\u0628 \u062a\u0634\u0627\u0628\u0643\u0627\u064b \u0639\u0628\u0631 \u0642\u0648\u0627\u0637\u0639 \u0623\u062e\u0631\u0649<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>\u0645\u0643\u0648\u0646\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646 \u0645\u0634\u0645\u0648\u0644\u0627\u064b \u0648\u062a\u0642\u062f\u064a\u0645 \u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0645\u062e\u0637\u0637\u0627\u062a<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0641\u0635\u0644 \u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0627\u0644\u0633\u062d\u0628<\/td>\n<td>\u0628\u064a\u0627\u0646 \u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u0625\u064a\u062c\u0627\u0628\u064a \u0623\u0648 \u0627\u0644\u0633\u0644\u0628\u064a \u0625\u0646 \u0627\u0646\u0637\u0628\u0642<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0636\u0639<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0633\u0644\u0648\u0643 \u0645\u0648\u0627\u0636\u0639 \u0627\u0644\u062e\u062f\u0645\u0629 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u0641\u0635\u0644 \u0648\u0627\u0644\u0633\u062d\u0628 \u0628\u062d\u0633\u0628 \u0627\u0644\u0627\u0642\u062a\u0636\u0627\u0621<\/td>\n<\/tr>\n<tr>\n<td>17<\/td>\n<td>\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0648\u0627\u062c\u0647\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0623\u0648 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0646 \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>18<\/td>\n<td>\u0622\u0644\u064a\u0629 \u0642\u0641\u0644 \u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a<\/td>\n<td>\u0628\u064a\u0627\u0646 \u0645\u0627 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0644\u0644\u062a\u0634\u0627\u0628\u0643 \u0645\u0646 \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>19<\/td>\n<td>\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u064a \u062a\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u0639\u0644\u064a\u0627\u064b<\/td>\n<\/tr>\n<tr>\n<td>20<\/td>\n<td>\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0623\u0648 \u0627\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u064a \u062a\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td>\n<\/tr>\n<tr>\n<td>21<\/td>\n<td>\u0627\u0644\u0641\u062d\u0648\u0635 \u0627\u0644\u0648\u0638\u064a\u0641\u064a\u0629 FAT<\/td>\n<td>\u0625\u062f\u0631\u0627\u062c \u0641\u062d\u0648\u0635 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0641\u0635\u0644 \u0648\u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0645\u0648\u0636\u0639 \u0648\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u062d\u062c\u0628<\/td>\n<\/tr>\n<tr>\n<td>22<\/td>\n<td>\u062d\u062f\u0648\u062f \u0646\u0637\u0627\u0642 \u0627\u0644\u062a\u0648\u0631\u064a\u062f<\/td>\n<td>\u062a\u062d\u062f\u064a\u062f \u0645\u0627 \u064a\u0648\u0631\u062f \u0645\u0639 VCB \u0648\u0645\u0627 \u064a\u0648\u0631\u062f\u0647 \u0645\u0635\u0646\u0639 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u064a\u062d\u0627\u0641\u0638 \u0647\u0630\u0627 \u0627\u0644\u062c\u062f\u0648\u0644 \u0639\u0644\u0649 \u0645\u0648\u0636\u0648\u0639\u064a\u0629 RFQ. \u0641\u0647\u0648 \u064a\u0637\u0644\u0628 \u0645\u0646 \u0645\u0648\u0631\u062f VCB \u0627\u0644\u062a\u0635\u0631\u064a\u062d \u0628\u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0648\u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0648\u0627\u0644\u0631\u0633\u0648\u0645\u0627\u062a \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0641\u0631\u0636 \u0641\u0644\u0633\u0641\u0629 \u062a\u062d\u0643\u0645 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u062a\u0635\u0645\u064a\u0645\u0627\u062a \u0642\u0648\u0627\u0637\u0639 \u0645\u062e\u062a\u0644\u0641\u0629.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-rfq-data-sheet-mandatory-control-circuit-and-interlocking-fields-fig-04.webp\" alt=\"XBRELE \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u0644\u0640VCB: \u062d\u0642\u0648\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0625\u0644\u0632\u0627\u0645\u064a\u0629 - \u062a\u0633\u0644\u064a\u0645 \u0627\u0644\u062a\u0648\u0631\u064a\u062f\" \/><\/figure>\n<h3>\u0635\u064a\u0627\u063a\u0629 RFQ \u0634\u0627\u0626\u0639\u0629 \u0644\u0646\u0637\u0627\u0642 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643<\/h3>\n<p>\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062a\u0636\u0645\u0646 RFQ \u0627\u0644\u0635\u064a\u0627\u063a\u0629 \u0627\u0644\u062a\u0627\u0644\u064a\u0629:<\/p>\n<p>\u00ab\u0639\u0644\u0649 \u0645\u0648\u0631\u062f VCB \u062a\u0642\u062f\u064a\u0645 \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a \u0643\u0627\u0645\u0644\u0629 \u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0644\u0644\u0642\u0627\u0637\u0639 \u0627\u0644\u0645\u0639\u0631\u0648\u0636. \u0648\u064a\u062c\u0628 \u0623\u0646 \u064a\u062d\u062f\u062f \u0627\u0644\u062a\u0642\u062f\u064a\u0645 \u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u0645\u0644\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0648\u0645\u062d\u0631\u0631 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062a\u062d\u0648\u064a\u0644\u064a \u0623\u0648 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644\u060c \u0648\u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0623\u0648 \u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e\u060c \u0648\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u060c \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0622\u0644\u064a\u0629\u060c \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0645\u063a\u0646\u0627\u0637\u064a\u0633 \u0627\u0644\u062d\u062c\u0628\u060c \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u062a\u0634\u0627\u0628\u0643 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637\u060c \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642\u060c \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52\u060c \u0648\u062a\u0634\u0627\u0628\u0643\u0627\u062a \u0627\u0644\u0639\u0631\u0628\u0629 \u0623\u0648 \u0627\u0644\u0633\u062d\u0628\u060c \u0648\u0623\u064a \u0648\u0627\u062c\u0647\u0627\u062a \u062a\u0634\u0627\u0628\u0643 \u0645\u0637\u0644\u0648\u0628\u0629 \u0645\u0646 \u062c\u0627\u0646\u0628 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636. \u0648\u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0645\u062e\u0637\u0637\u0627\u062a \u0627\u0644\u0639\u0646\u0635\u0631\u064a\u0629 \u0648\u0645\u062e\u0637\u0637\u0627\u062a \u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u062c\u062f\u0648\u0644 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u064a\u0648\u0636\u062d \u0648\u0638\u064a\u0641\u0629 \u0643\u0644 \u062a\u0644\u0627\u0645\u0633 \u062a\u062d\u0643\u0645 \u0623\u0648 \u062a\u0634\u0627\u0628\u0643 \u0648\u0645\u0648\u0636\u0639\u0647 \u0648\u062d\u0627\u0644\u062a\u0647 \u0627\u0644\u0637\u0628\u064a\u0639\u064a\u0629 \u0648\u0648\u062c\u0647\u0629 \u062a\u0648\u0635\u064a\u0644\u0647. \u0643\u0645\u0627 \u064a\u062c\u0628 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u0623\u0643\u064a\u062f \u0623\u0646 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0642\u0627\u0637\u0639 \u063a\u064a\u0631 \u0645\u0648\u0635\u0644\u0629 \u0628\u0637\u0631\u064a\u0642\u0629 \u062a\u0639\u0637\u0644 \u0648\u0638\u064a\u0641\u0629 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0627\u0644\u0645\u0642\u0635\u0648\u062f\u0629.\u00bb \u0627\u0633\u062a\u062e\u062f\u0645 <a href=\"https:\/\/xbrele.com\/ar\/vcb-closing-opening-failure-troubleshooting\/\">\u062f\u0644\u064a\u0644 \u0627\u0633\u062a\u0643\u0634\u0627\u0641 \u0623\u0639\u0637\u0627\u0644 \u062a\u0634\u063a\u064a\u0644 VCB<\/a> \u0644\u062a\u0645\u064a\u064a\u0632 \u0623\u0633\u0628\u0627\u0628 \u0639\u0637\u0644 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u0648 \u0627\u0644\u0645\u0644\u0641 \u0623\u0648 \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0623\u0648 \u0627\u0644\u0622\u0644\u064a\u0629 \u0628\u0639\u062f \u0641\u0634\u0644 \u0639\u0645\u0644\u064a\u0629 \u062a\u0634\u063a\u064a\u0644.<\/p>\n<p>\u062a\u0628\u0642\u0649 \u0647\u0630\u0647 \u0627\u0644\u0635\u064a\u0627\u063a\u0629 \u0636\u0645\u0646 \u0645\u0641\u0627\u0647\u064a\u0645 \u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0645\u0648\u062b\u0642\u0629 \u0641\u064a VCB\u060c \u0645\u0639 \u0625\u0644\u0632\u0627\u0645 \u0627\u0644\u0639\u0631\u0636 \u0628\u0625\u0638\u0647\u0627\u0631 \u0627\u0644\u062a\u0641\u0627\u0635\u064a\u0644 \u0627\u0644\u0645\u0647\u0645\u0629 \u0644\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0647\u0646\u062f\u0633\u064a\u0629.<\/p>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3>\u0645\u0627 \u0648\u0631\u0642\u0629 \u0628\u064a\u0627\u0646\u0627\u062a RFQ \u0644\u062a\u0634\u0627\u0628\u0643 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a VCB\u061f<\/h3>\n<p>\u0647\u064a \u062c\u062f\u0648\u0644 \u064a\u0633\u062a\u0643\u0645\u0644\u0647 \u0627\u0644\u0645\u0648\u0631\u062f \u0644\u062a\u062d\u062f\u064a\u062f \u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0627\u0644\u0641\u0635\u0644 \u0648\u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u0627\u0644\u0634\u062d\u0646 \u0648\u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0648\u0627\u0644\u062d\u062c\u0628 \u0648\u0627\u0644\u0633\u062d\u0628 \u0648\u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0645\u0639 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0641\u064a \u0627\u0644\u0642\u0627\u0637\u0639. \u0648\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u064a\u062a\u0636\u0645\u0646 \u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0645\u062e\u0637\u0637\u0627\u062a \u0648\u0627\u0644\u0623\u0637\u0631\u0627\u0641 \u0648\u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0648\u062d\u062f\u0648\u062f \u0627\u0644\u0646\u0637\u0627\u0642 \u0643\u064a \u064a\u062a\u062d\u0642\u0642 \u0627\u0644\u0645\u0634\u062a\u0631\u064a \u0645\u0646 \u0643\u064a\u0641\u064a\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a VCB \u0648\u062a\u0634\u0627\u0628\u0643\u0647 \u0645\u0639 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.<\/p>\n<h3>\u0645\u0627 \u0623\u0647\u0645 \u062d\u0642\u0644 \u0644\u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0641\u064a RFQ \u062e\u0627\u0635\u0629 \u0628\u0640VCB\u061f<\/h3>\n<p>\u0623\u0647\u0645 \u062d\u0642\u0644 \u0647\u0648 \u062a\u0635\u0631\u064a\u062d \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u0643\u064a\u0641\u064a\u0629 \u062a\u062d\u0642\u064a\u0642 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u062d\u0645\u0627\u064a\u062a\u0647 \u0645\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u062e\u0627\u0637\u0626 \u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642. \u0648\u062a\u062d\u062f\u062f \u0648\u062b\u0627\u0626\u0642 ABB \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0640VCB \u0645\u0631\u062d\u0644\u0627\u062a \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0643\u062c\u0632\u0621 \u0645\u0646 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u062d\u0643\u0645\u060c \u0648\u062a\u062d\u0630\u0631 \u0625\u0631\u0634\u0627\u062f\u0627\u062a Schneider \u0645\u0646 \u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0642\u0627\u0637\u0639 \u0639\u0644\u0649 \u0627\u0644\u062a\u0648\u0627\u0644\u064a \u0645\u0639 \u0645\u062d\u0631\u0631 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0628\u0637\u0631\u064a\u0642\u0629 \u062a\u0639\u0637\u0644 \u0646\u0638\u0627\u0645 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a.<\/p>\n<h3>\u0645\u0627 \u0627\u0644\u0641\u0631\u0642 \u0628\u064a\u0646 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0642\u0627\u0637\u0639 \u0648\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0634\u0627\u0628\u0643\u061f<\/h3>\n<p>\u062a\u0634\u064a\u0631 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0642\u0627\u0637\u0639 \u0639\u0645\u0648\u0645\u0627\u064b \u0625\u0644\u0649 \u062d\u0627\u0644\u0629 \u0622\u0644\u064a\u0629 \u0627\u0644\u0642\u0627\u0637\u0639 \u0623\u0648 \u062a\u062a\u0628\u0639\u0647\u0627\u060c \u0645\u062b\u0644 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52 \u0623\u0648 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u0645\u0633\u0627\u0639\u062f\u0629 \u0644\u0644\u0622\u0644\u064a\u0629. \u0623\u0645\u0627 \u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0641\u062a\u0633\u062a\u062e\u062f\u0645 \u0644\u0644\u0633\u0645\u0627\u062d \u0628\u0639\u0645\u0644\u064a\u0627\u062a \u0645\u062b\u0644 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u0627\u0644\u0641\u0635\u0644 \u0623\u0648 \u062a\u0634\u063a\u064a\u0644 \u0623\u0632\u0631\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 \u0623\u0648 \u0627\u0644\u0633\u062d\u0628 \u0623\u0648 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u062a\u0646\u0633\u064a\u0642 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636\u060c \u0623\u0648 \u0644\u062d\u062c\u0628\u0647\u0627 \u0623\u0648 \u062a\u0646\u0633\u064a\u0642\u0647\u0627. \u0648\u0642\u062f \u062a\u0638\u0647\u0631 \u0628\u0639\u0636 \u0627\u0644\u062a\u0644\u0627\u0645\u0633\u0627\u062a \u0641\u064a \u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u062d\u0643\u0645 \u0646\u0641\u0633\u0647\u060c \u0644\u0643\u0646 \u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 RFQ \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f \u0628\u064a\u0627\u0646 \u0627\u0644\u0648\u0638\u064a\u0641\u0629 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0644\u0643\u0644 \u062a\u0644\u0627\u0645\u0633.<\/p>\n<h3>\u0645\u0627 \u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u062a\u062d\u0643\u0645 VCB\u061f<\/h3>\n<p>\u0647\u0648 \u062a\u0644\u0627\u0645\u0633 \u0645\u0633\u062a\u062e\u062f\u0645 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u0627\u0644\u062a\u0634\u0627\u0628\u0643 \u0644\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0641\u064a \u0638\u0631\u0648\u0641 \u0645\u062d\u062f\u062f\u0629. \u0648\u062a\u0635\u0641 \u0648\u062b\u0627\u0626\u0642 ABB SecoVac \u062a\u0644\u0627\u0645\u0633 \u062d\u062c\u0628 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0625\u0644\u0649 \u062c\u0627\u0646\u0628 \u0645\u0644\u0641 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0648\u0645\u0631\u062d\u0644 \u0645\u0646\u0639 \u0627\u0644\u0636\u062e \u0648\u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0645\u0633\u0627\u0639\u062f 52 \u0648\u0645\u0644\u0641\u0627\u062a \u0627\u0644\u0641\u0635\u0644 \u0648\u0645\u062d\u0631\u0643 \u0634\u062d\u0646 \u0627\u0644\u0632\u0646\u0628\u0631\u0643 \u0648\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062d\u062c\u0628 \u0648\u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0639\u0631\u0628\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629. \u0648\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 RFQ \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0648\u0638\u0631\u0648\u0641 \u062a\u0634\u063a\u064a\u0644\u0647 \u0648\u0645\u0648\u0636\u0639\u0647 \u0641\u064a \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0625\u063a\u0644\u0627\u0642.<\/p>\n<h3>\u0645\u0627 \u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0636\u0639 \u0641\u064a VCB\u061f<\/h3>\n<p>\u064a\u0639\u0646\u064a \u0623\u0646 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0623\u0648 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0640VCB \u064a\u0645\u0643\u0646 \u0645\u0646\u0639\u0647 \u0628\u0646\u0627\u0621\u064b \u0639\u0644\u0649 \u0645\u0648\u0636\u0639\u0647 \u0623\u0648 \u0645\u0648\u0636\u0639 \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0631\u062a\u0628\u0637\u0629 \u0628\u0647. \u0648\u062a\u0635\u0641 \u0648\u062b\u0627\u0626\u0642 Siemens \u062a\u0634\u0627\u0628\u0643\u0627\u062a VCB \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629\u060c \u0628\u0645\u0627 \u0641\u064a\u0647\u0627 \u062a\u0634\u0627\u0628\u0643 \u0627\u0644\u0641\u0627\u0635\u0644 \u0623\u0648 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u0623\u0631\u064a\u0636 \u0639\u0628\u0631 \u0622\u0644\u064a\u0627\u062a \u0627\u0644\u0642\u0641\u0644 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a \u0648\u0645\u0646\u0639 \u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a \u0648\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0645\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0636\u0639. \u0648\u064a\u0646\u0628\u063a\u064a \u0623\u0646 \u062a\u0637\u0644\u0628 RFQ \u0645\u0646 \u0627\u0644\u0645\u0648\u0631\u062f \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0645\u0648\u0627\u0636\u0639 \u0627\u0644\u062a\u064a \u062a\u0633\u0645\u062d \u0628\u0627\u0644\u0625\u063a\u0644\u0627\u0642 \u0623\u0648 \u062a\u062d\u062c\u0628\u0647.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quick Takeaway Confirm the project duty and applicable requirements for VCB before selection or service work. Use recorded inspection and test evidence instead of unsupported assumptions. Keep the final acceptance, maintenance, and handover documents with the equipment record. A VCB RFQ data sheet should not treat the control circuit as a generic accessory list. For [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4187,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-4192","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/4192","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/comments?post=4192"}],"version-history":[{"count":2,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/4192\/revisions"}],"predecessor-version":[{"id":4279,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/posts\/4192\/revisions\/4279"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media\/4187"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/media?parent=4192"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/categories?post=4192"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ar\/wp-json\/wp\/v2\/tags?post=4192"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}