{"id":1107,"date":"2025-11-18T09:39:28","date_gmt":"2025-11-18T09:39:28","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1107"},"modified":"2025-11-20T10:13:20","modified_gmt":"2025-11-20T10:13:20","slug":"zw32-vacuum-circuit-breaker","status":"publish","type":"page","link":"https:\/\/xbrele.com\/de\/vacuum-circuit-breaker\/zw32-vacuum-circuit-breaker\/","title":{"rendered":"zw32 Vakuum-Leistungsschalter"},"content":{"rendered":"\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-3f3b329\" data-block-id=\"3f3b329\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-3f3b329-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-4b1ff0c\" data-v=\"4\" data-block-id=\"4b1ff0c\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-4b1ff0c-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-4b1ff0c-inner-blocks\">\n<section id=\"sec1-zw32-hero\" style=\"position:relative;overflow:hidden;background:radial-gradient(circle at top left,#0f172a 0,#020617 55%,#020617 100%);color:#e5e7eb;padding:200px 0 128px;\">\n  <style>\n    #sec1-zw32-hero{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec1-zw32-hero .zw32-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec1-zw32-hero .zw32-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:48px;\n      align-items:center;\n    }\n    #sec1-zw32-hero .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38bdf8;\n      margin-bottom:10px;\n    }\n    #sec1-zw32-hero h1{\n      font-size:40px;\n      line-height:1.1;\n      letter-spacing:-.03em;\n      margin:0 0 14px;\n      color:#f9fafb;\n    }\n    #sec1-zw32-hero p.sub{\n      max-width:660px;\n      font-size:16px;\n      line-height:1.75;\n      margin:0 0 20px;\n      color:#cbd5f5;\n    }\n    \/* Badges *\/\n    #sec1-zw32-hero .badges{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:22px 0 32px;\n    }\n    #sec1-zw32-hero .badge{\n      padding:6px 12px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid rgba(148,163,184,.55);\n      background:rgba(15,23,42,.45);\n      backdrop-filter:blur(14px);\n      color:#e5e7eb;\n    }\n    \/* Right card *\/\n    #sec1-zw32-hero .hero-card{\n      position:relative;\n      border-radius:20px;\n      padding:22px 22px 18px;\n      background:radial-gradient(circle at top left,rgba(56,189,248,.20) 0,rgba(15,23,42,.95) 36%,rgba(15,23,42,1) 100%);\n      border:1px solid rgba(148,163,184,.4);\n      box-shadow:0 18px 45px rgba(15,23,42,.9);\n      color:#e5e7eb;\n    }\n    #sec1-zw32-hero .hero-card h3{\n      font-size:15px;\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      color:#bae6fd;\n      margin:0 0 10px;\n    }\n    #sec1-zw32-hero .hero-card p{\n      font-size:13px;\n      line-height:1.7;\n      color:#cbd5f5;\n      margin:0 0 16px;\n    }\n    #sec1-zw32-hero .spec-grid{\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:12px 20px;\n      font-size:12px;\n    }\n    .spec-label{\n      text-transform:uppercase;\n      letter-spacing:.12em;\n      color:#9ca3af;\n      margin-bottom:2px;\n      font-size:11px;\n    }\n    .spec-value{\n      font-weight:500;\n      color:#e5e7eb;\n    }\n\n    @media(max-width:1000px){\n      #sec1-zw32-hero .zw32-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec1-zw32-hero h1{font-size:30px;}\n      #sec1-zw32-hero .zw32-shell{padding:0 18px;}\n    }\n  <\/style>\n\n  <div class=\"zw32-shell\">\n    <div class=\"zw32-grid\">\n\n      <!-- Left content -->\n      <div>\n        <div class=\"kicker\">Vacuum Circuit Breakers \u00b7 Series<\/div>\n        <h1>ZW32 Vacuum Circuit Breaker Series<\/h1>\n\n        <p class=\"sub\">\n          ZW32 series outdoor vacuum circuit breakers are widely used on 12kV and 40.5kV distribution networks.\n          The unit integrates vacuum interrupter, solid-insulated embedded pole, operating mechanism and current\n          transformer, offering reliable breaking performance for overhead lines, ring main systems and compact substations.\n        <\/p>\n\n        <div class=\"badges\">\n          <span class=\"badge\">12kV<\/span>\n          <span class=\"badge\">40.5kV<\/span>\n          <span class=\"badge\">Outdoor<\/span>\n          <span class=\"badge\">Pole-mounted<\/span>\n          <span class=\"badge\">Vacuum Interruption<\/span>\n        <\/div>\n      <\/div>\n\n      <!-- Right card -->\n      <aside class=\"hero-card\">\n        <h3>Key Ratings Overview<\/h3>\n        <p>\n          Based on your catalog: ZW32 series covers both 12kV and 40.5kV voltage levels, designed for outdoor overhead distribution lines.\n          Replace numbers below with your final certified data.\n        <\/p>\n\n        <div class=\"spec-grid\">\n          <div>\n            <div class=\"spec-label\">Voltage levels<\/div>\n            <div class=\"spec-value\">12kV \/ 40.5kV<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Rated current<\/div>\n            <div class=\"spec-value\">630A \/ 1250A<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Breaking current<\/div>\n            <div class=\"spec-value\">20\u201331.5 kA<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Mechanical life<\/div>\n            <div class=\"spec-value\">10,000 ops<\/div>\n          <\/div>\n        <\/div>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-b6de7e1\" data-block-id=\"b6de7e1\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-b6de7e1-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-eafa158\" data-v=\"4\" data-block-id=\"eafa158\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-eafa158-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-eafa158-inner-blocks\">\n<section id=\"sec2-zw32-overview\" style=\"background:#ffffff;padding:90px 0 105px;color:#0f172a;\">\n  <style>\n    #sec2-zw32-overview{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec2-zw32-overview .zw32-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec2-zw32-overview .overview-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.4fr) minmax(0,1fr);\n      gap:52px;\n      align-items:center;\n    }\n    #sec2-zw32-overview .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38bdf8;\n      margin-bottom:10px;\n    }\n    #sec2-zw32-overview h2{\n      font-size:28px;\n      margin:0 0 14px;\n      color:#0f172a;\n    }\n    #sec2-zw32-overview p{\n      font-size:16px;\n      line-height:1.85;\n      margin:0 0 16px;\n      color:#4b5563;\n    }\n    #sec2-zw32-overview .apps-box{\n      background:#f9fafb;\n      padding:22px 24px 20px;\n      border-radius:18px;\n      border:1px solid #e5e7eb;\n    }\n    #sec2-zw32-overview .apps-box h3{\n      font-size:15px;\n      margin:0 0 12px;\n      text-transform:uppercase;\n      letter-spacing:.14em;\n      color:#6b7280;\n    }\n    #sec2-zw32-overview ul{\n      list-style:none;\n      padding:0;\n      margin:0;\n      display:grid;\n      gap:10px;\n      font-size:14px;\n      color:#374151;\n    }\n    #sec2-zw32-overview ul li{\n      position:relative;\n      padding-left:16px;\n      line-height:1.7;\n    }\n    #sec2-zw32-overview ul li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38bdf8;\n    }\n\n    @media(max-width:1000px){\n      #sec2-zw32-overview .overview-grid{\n        grid-template-columns:1fr;\n      }\n    }\n  <\/style>\n\n  <div class=\"zw32-shell\">\n    <div class=\"overview-grid\">\n\n      <!-- LEFT TEXT -->\n      <div>\n        <div class=\"kicker\">Series overview<\/div>\n        <h2>ZW32 vacuum circuit breaker with integrated pole &amp; operating mechanism<\/h2>\n\n        <p>\n          ZW32 series is an outdoor high-voltage vacuum circuit breaker designed for overhead distribution\n          networks. Each unit integrates the vacuum interrupter, solid-insulated embedded pole,\n          operating mechanism and current transformer into a compact body, forming a fully enclosed\n          structure suitable for long-term field operation.\n        <\/p>\n\n        <p>\n          The embedded pole design improves insulation performance and protects the interrupter from\n          moisture, dust and environmental stress. Combined with a stable spring operating mechanism, the\n          breaker provides dependable opening and closing under frequent switching conditions.\n        <\/p>\n\n        <p>\n          The series includes models for both <strong>12kV<\/strong> and <strong>40.5kV<\/strong>, allowing utilities and\n          EPC contractors to deploy a unified breaker platform across different distribution voltage levels.\n          Line-mounted installation reduces on-site work and shortens outage windows during upgrades or replacements.\n        <\/p>\n\n        <p style=\"margin-top:14px;font-size:14px;color:#4b5563;\">\n          For a broader look at XBRELE\u2019s outdoor and indoor VCB ranges, please visit the\n          <a href=\"https:\/\/xbrele.com\/vacuum-circuit-breaker\/\" style=\"color:#2563EB;text-decoration:none;\">\n            Vacuum Circuit Breaker pillar page\n          <\/a>.\n        <\/p>\n      <\/div>\n\n      <!-- RIGHT BOX -->\n      <aside class=\"apps-box\">\n        <h3>Typical applications<\/h3>\n        <ul>\n          <li>Overhead line sectionalizing and feeder switching<\/li>\n          <li>Pole-mounted distribution automation points<\/li>\n          <li>Urban &amp; rural distribution line protection<\/li>\n          <li>Compact substations and RMU interfacing<\/li>\n          <li>Wind \/ solar farm outgoing or tie lines<\/li>\n        <\/ul>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-cfcf9fa\" data-block-id=\"cfcf9fa\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-cfcf9fa-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-8271d65\" data-v=\"4\" data-block-id=\"8271d65\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-8271d65-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-8271d65-inner-blocks\">\n<section id=\"sec3-zw32-tech\" style=\"padding:90px 0;background:#F9FAFB;\">\n  <style>\n    #sec3-zw32-tech{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec3-zw32-tech .tech-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec3-zw32-tech .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec3-zw32-tech .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec3-zw32-tech h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-zw32-tech .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    \/* TAB Row *\/\n    #sec3-zw32-tech .tab-row{\n      display:flex;\n      justify-content:center;\n      gap:16px;\n      margin:34px 0 32px;\n    }\n    #sec3-zw32-tech .tab-btn{\n      padding:10px 26px;\n      font-size:15px;\n      font-weight:600;\n      background:#E5E7EB;\n      border-radius:6px;\n      cursor:pointer;\n      border:1px solid #D1D5DB;\n      transition:all .25s ease;\n      color:#0F172A;\n      white-space:nowrap;\n    }\n    #sec3-zw32-tech .tab-btn:hover{\n      background:#DDE3E9;\n    }\n    #sec3-zw32-tech .tab-btn.active{\n      background:#0F172A;\n      color:#F9FAFB;\n      border-color:#0F172A;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n    }\n\n    \/* Panels *\/\n    #sec3-zw32-tech .tab-content{\n      display:none;\n      animation:fadeIn .25s ease;\n    }\n    #sec3-zw32-tech .tab-content.active{\n      display:block;\n    }\n    @keyframes fadeIn{\n      from{opacity:0;transform:translateY(6px);}\n      to{opacity:1;transform:translateY(0);}\n    }\n\n    \/* Panel layout *\/\n    #sec3-zw32-tech .panel-card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:24px 22px 26px;\n      box-shadow:0 14px 32px rgba(15,23,42,.05);\n    }\n    #sec3-zw32-tech .panel-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.15fr) minmax(0,1.1fr);\n      gap:22px;\n      margin-bottom:20px;\n      align-items:flex-start;\n    }\n    #sec3-zw32-tech figure.main-fig{\n      margin:0;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:10px;\n    }\n    #sec3-zw32-tech figure.main-fig img{\n      display:block;\n      width:100%;\n      max-height:300px;\n      object-fit:contain;\n    }\n    #sec3-zw32-tech figure.main-fig figcaption{\n      margin-top:8px;\n      font-size:12px;\n      color:#6B7280;\n      line-height:1.6;\n    }\n    #sec3-zw32-tech .panel-right h3{\n      font-size:16px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-zw32-tech .panel-right p{\n      font-size:14px;\n      line-height:1.8;\n      margin:0 0 10px;\n      color:#4B5563;\n    }\n    #sec3-zw32-tech .badge-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:8px 0 14px;\n    }\n    #sec3-zw32-tech .badge{\n      padding:4px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid #D1D5DB;\n      background:#F9FAFB;\n      color:#4B5563;\n    }\n\n    \/* tables & dimension block *\/\n    #sec3-zw32-tech .block-title{\n      font-size:14px;\n      font-weight:600;\n      margin:4px 0 6px;\n      color:#111827;\n    }\n    #sec3-zw32-tech .block-note{\n      font-size:12px;\n      color:#6B7280;\n      margin:0 0 10px;\n    }\n    #sec3-zw32-tech .table-wrap{\n      width:100%;\n      overflow-x:auto;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      margin-bottom:18px;\n    }\n    #sec3-zw32-tech table{\n      width:100%;\n      border-collapse:collapse;\n      font-size:13px;\n      min-width:520px;\n    }\n    #sec3-zw32-tech thead{\n      background:#E5F0FF;\n    }\n    #sec3-zw32-tech th,\n    #sec3-zw32-tech td{\n      padding:8px 10px;\n      border-bottom:1px solid #E5E7EB;\n      text-align:left;\n      color:#111827;\n    }\n    #sec3-zw32-tech th{\n      font-size:12px;\n      text-transform:uppercase;\n      letter-spacing:.08em;\n      color:#374151;\n      font-weight:600;\n    }\n    #sec3-zw32-tech tbody tr:nth-child(odd){\n      background:#FFFFFF;\n    }\n    #sec3-zw32-tech tbody tr:nth-child(even){\n      background:#F9FAFB;\n    }\n\n    #sec3-zw32-tech .dim-block{\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:20px;\n      margin-top:8px;\n      align-items:stretch;\n    }\n    #sec3-zw32-tech .dim-fig{\n      margin:0;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:12px;\n    }\n    #sec3-zw32-tech .dim-fig img{\n      display:block;\n      width:100%;\n      max-height:460px;\n      object-fit:contain;\n    }\n    #sec3-zw32-tech .dim-fig figcaption{\n      margin-top:6px;\n      font-size:12px;\n      color:#6B7280;\n    }\n\n    #sec3-zw32-tech .dim-right{\n      display:flex;\n      flex-direction:column;\n      justify-content:space-between; \/* \u8ba9 CTA \u8d34\u8fd1\u5e95\u90e8\uff0c\u4e0e\u5de6\u4fa7\u5bf9\u9f50 *\/\n    }\n\n    \/* CTA *\/\n    #sec3-zw32-tech .cta-right-col{\n      display:flex;\n      justify-content:center;\n      margin-top:26px;\n    }\n    #sec3-zw32-tech .cta-btn{\n      display:inline-block;\n      padding:12px 30px;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:15px;\n      font-weight:600;\n      border-radius:8px;\n      text-decoration:none;\n      letter-spacing:.03em;\n      transition:all .25s ease;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n      white-space:nowrap;\n    }\n    #sec3-zw32-tech .cta-btn:hover{\n      background:#1E293B;\n      box-shadow:0 14px 32px rgba(15,23,42,.25);\n      transform:translateY(-1px);\n    }\n\n    @media(max-width:1000px){\n      #sec3-zw32-tech .panel-grid,\n      #sec3-zw32-tech .dim-block{\n        grid-template-columns:1fr;\n      }\n      #sec3-zw32-tech .cta-right-col{\n        justify-content:flex-start;\n      }\n    }\n    @media(max-width:690px){\n      #sec3-zw32-tech .tech-shell{padding:0 18px;}\n      #sec3-zw32-tech h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"tech-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Technical data &#038; installation dimensions<\/div>\n      <h2>ZW32-12 &amp; ZW32-40.5 \u2014 specifications and outline drawings<\/h2>\n      <p>\n        Select the voltage level below to view the corresponding product photo, key electrical ratings,\n        and outline &amp; mounting dimensions for engineering design and selection.\n      <\/p>\n    <\/div>\n\n    <!-- TAB BUTTONS -->\n    <div class=\"tab-row\">\n      <div class=\"tab-btn active\" data-tab=\"zw32-12\">ZW32-12 \u00b7 12kV<\/div>\n      <div class=\"tab-btn\" data-tab=\"zw32-40\">ZW32-40.5 \u00b7 40.5kV<\/div>\n    <\/div>\n\n    <!-- PANEL 1: ZW32-12 -->\n    <div id=\"zw32-12\" class=\"tab-content active\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <figure class=\"main-fig\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ZW32-12-Vacuum-circuit-breaker.webp\"\n                 alt=\"ZW32-12 outdoor vacuum circuit breaker 12kV \u2013 XBRELE\">\n            <figcaption>ZW32-12 outdoor vacuum circuit breaker (12kV), pole-mounted construction with embedded pole.<\/figcaption>\n          <\/figure>\n\n          <div class=\"panel-right\">\n            <h3>ZW32-12 technical overview<\/h3>\n            <p>\n              ZW32-12 is an outdoor vacuum circuit breaker for 12kV overhead distribution networks, typically\n              used as feeder breaker, sectionalizing switch or tie switch on pole-mounted structures.\n            <\/p>\n            <p>\n              The breaker adopts a solid-insulated embedded pole and spring operating mechanism, providing\n              reliable switching performance under frequent operations and harsh outdoor environments.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">12kV<\/span>\n              <span class=\"badge\">Outdoor<\/span>\n              <span class=\"badge\">Pole-mounted<\/span>\n              <span class=\"badge\">Embedded pole<\/span>\n            <\/div>\n            <p>\n              The table below lists the main electrical ratings for ZW32-12.\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <!-- 12kV Specs -->\n        <p class=\"block-title\">Key electrical ratings \u2014 ZW32-12<\/p>\n        <p class=\"block-note\">Values according to the ZW32-12 technical parameter sheet.<\/p>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th style=\"width:56px;\">No.<\/th>\n                <th>Item<\/th>\n                <th style=\"width:80px;\">Unit<\/th>\n                <th>ZW32-12<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <tr><td>1<\/td><td>Rated voltage<\/td><td>kV<\/td><td>12<\/td><\/tr>\n              <tr><td>2<\/td><td>Rated current<\/td><td>A<\/td><td>630 \/ 1250<\/td><\/tr>\n              <tr><td>3<\/td><td>Rated frequency<\/td><td>Hz<\/td><td>50<\/td><\/tr>\n              <tr><td>4<\/td><td>Power-frequency withstand voltage (1 min, dry-type, phase-to-phase \/ across break)<\/td><td>kV<\/td><td>42 \/ 48<\/td><\/tr>\n              <tr><td>5<\/td><td>Power-frequency withstand voltage (1 min, wet-type)<\/td><td>kV<\/td><td>34<\/td><\/tr>\n              <tr><td>6<\/td><td>Power-frequency withstand voltage (1 min, secondary circuit to ground)<\/td><td>kV<\/td><td>2<\/td><\/tr>\n              <tr><td>7<\/td><td>Lightning impulse withstand voltage (peak, phase-to-phase \/ across break)<\/td><td>kV<\/td><td>75 \/ 85<\/td><\/tr>\n              <tr><td>8<\/td><td>Rated short-circuit breaking current<\/td><td>kA<\/td><td>20 \/ 25<\/td><\/tr>\n              <tr><td>9<\/td><td>Rated short-circuit closing current (peak)<\/td><td>kA<\/td><td>50 \/ 63<\/td><\/tr>\n              <tr><td>10<\/td><td>Rated short-term withstand current<\/td><td>kA<\/td><td>20 \/ 25<\/td><\/tr>\n              <tr><td>11<\/td><td>Rated peak withstand current<\/td><td>kA<\/td><td>50 \/ 63<\/td><\/tr>\n              <tr><td>12<\/td><td>Rated short-circuit breaking current breaking times<\/td><td>operations<\/td><td>30<\/td><\/tr>\n              <tr><td>13<\/td><td>Rated short-circuit duration<\/td><td>s<\/td><td>4<\/td><\/tr>\n              <tr><td>14<\/td><td>Rated operating voltage \/ auxiliary circuit voltage<\/td><td>V<\/td><td>DC\/AC110; AC\/DC220<\/td><\/tr>\n              <tr><td>15<\/td><td>Rated operating sequence<\/td><td>\u2014<\/td><td>O \u2013 0.3s \u2013 CO \u2013 180s \u2013 CO<\/td><\/tr>\n              <tr><td>16<\/td><td>Over-current trip rated current<\/td><td>A<\/td><td>5<\/td><\/tr>\n              <tr><td>17<\/td><td>Mechanical life<\/td><td>operations<\/td><td>10,000<\/td><\/tr>\n              <tr><td>18<\/td><td>Cumulative allowable wear of dynamic &amp; static contacts<\/td><td>mm<\/td><td>3<\/td><\/tr>\n              <tr><td>19<\/td><td>Rated current of overcurrent release<\/td><td>A<\/td><td>5<\/td><\/tr>\n              <tr><td>20<\/td><td>Current ratio of current transformer<\/td><td>A<\/td><td>200\/5; 400\/5; 600\/5<\/td><\/tr>\n              <tr><td>21<\/td><td>Contact spacing<\/td><td>mm<\/td><td>9 &plusmn; 1<\/td><\/tr>\n              <tr><td>22<\/td><td>Contact overtravel<\/td><td>mm<\/td><td>2.5 &plusmn; 0.5<\/td><\/tr>\n              <tr><td>23<\/td><td>Average opening speed<\/td><td>m\/s<\/td><td>1.0 &plusmn; 0.2<\/td><\/tr>\n              <tr><td>24<\/td><td>Average closing speed<\/td><td>m\/s<\/td><td>0.6 &plusmn; 0.2<\/td><\/tr>\n              <tr><td>25<\/td><td>Opening time<\/td><td>ms<\/td><td>&le; 50<\/td><\/tr>\n              <tr><td>26<\/td><td>Closing time<\/td><td>ms<\/td><td>&le; 100<\/td><\/tr>\n              <tr><td>27<\/td><td>Closing bounce time<\/td><td>ms<\/td><td>&le; 2<\/td><\/tr>\n              <tr><td>28<\/td><td>Different periods of three-pole closing and opening<\/td><td>ms<\/td><td>&le; 2<\/td><\/tr>\n              <tr><td>29<\/td><td>DC resistance of each phase loop<\/td><td>&micro;&Omega;<\/td><td>&le; 80 (band isolation &le; 150)<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n\n        <!-- 12kV Dimensions + drawing -->\n        <p class=\"block-title\">Outline &amp; mounting dimensions \u2014 ZW32-12<\/p>\n        <p class=\"block-note\">\n          Outline and mounting dimensions for typical ZW32-12 pole-mounted installation.\n        <\/p>\n        <div class=\"dim-block\">\n          <figure class=\"dim-fig\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/XBRELE-ZW32-40.5-Vacuum-circuit-breaker-installing-dimension.webp\"\n                 alt=\"ZW32 outline and mounting dimensions \u2013 XBRELE\">\n            <figcaption>ZW32 outline &amp; mounting dimensions for pole-mounted installation.<\/figcaption>\n          <\/figure>\n\n          <div class=\"dim-right\">\n            <div class=\"table-wrap\">\n              <table>\n                <thead>\n                  <tr>\n                    <th>Item<\/th><th>Symbol<\/th><th>Value (mm)<\/th><th>Note<\/th>\n                  <\/tr>\n                <\/thead>\n                <tbody>\n                  <tr><td>Overall height<\/td><td>H<\/td><td>\u2014<\/td><td>Overall height of breaker assembly<\/td><\/tr>\n                  <tr><td>Overall width<\/td><td>W<\/td><td>\u2014<\/td><td>Including phase spacing<\/td><\/tr>\n                  <tr><td>Mounting hole spacing (horizontal)<\/td><td>L1<\/td><td>\u2014<\/td><td>Base horizontal bolt distance<\/td><\/tr>\n                  <tr><td>Mounting hole spacing (vertical)<\/td><td>L2<\/td><td>\u2014<\/td><td>To match cross-arm or steel structure<\/td><\/tr>\n                  <tr><td>Mounting hole size<\/td><td>\u03a6<\/td><td>\u2014<\/td><td>Oval or round hole diameter<\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/div>\n\n            <div class=\"cta-right-col\">\n              <a href=\"#ct-popup-882\" class=\"cta-btn\">\n                Request a Quote from XBRELE\n              <\/a>\n            <\/div>\n          <\/div>\n        <\/div>\n\n      <\/div><!-- \/panel-card -->\n    <\/div><!-- \/zw32-12 -->\n\n    <!-- PANEL 2: ZW32-40.5 -->\n    <div id=\"zw32-40\" class=\"tab-content\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <figure class=\"main-fig\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ZW32-40.5-Vacuum-circuit-breaker.webp\"\n                 alt=\"ZW32-40.5 outdoor vacuum circuit breaker 40.5kV \u2013 XBRELE\">\n            <figcaption>ZW32-40.5 outdoor vacuum circuit breaker (40.5kV), suitable for overhead lines and substation feeders.<\/figcaption>\n          <\/figure>\n\n          <div class=\"panel-right\">\n            <h3>ZW32-40.5 technical overview<\/h3>\n            <p>\n              ZW32-40.5 is designed for medium-voltage overhead line power grids and 35\u201340.5kV substations,\n              providing higher insulation level and breaking capacity based on the same embedded pole concept.\n            <\/p>\n            <p>\n              The breaker combines a solid-sealed pole with a reliable operating mechanism, offering\n              long mechanical and electrical life with minimal maintenance.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">40.5kV<\/span>\n              <span class=\"badge\">Outdoor<\/span>\n              <span class=\"badge\">Pole \/ structure mounted<\/span>\n              <span class=\"badge\">High insulation level<\/span>\n            <\/div>\n            <p>\n              The table below lists typical electrical ratings for 40.5kV ZW32 configurations.\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <!-- 40.5kV Specs -->\n        <p class=\"block-title\">Key electrical ratings \u2014 ZW32-40.5<\/p>\n        <p class=\"block-note\">Typical values for 40.5kV outdoor vacuum circuit breaker applications.<\/p>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th style=\"width:56px;\">No.<\/th>\n                <th>Item<\/th>\n                <th style=\"width:80px;\">Unit<\/th>\n                <th>ZW32-40.5<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <tr><td>1<\/td><td>Rated voltage<\/td><td>kV<\/td><td>40.5<\/td><\/tr>\n              <tr><td>2<\/td><td>Rated frequency<\/td><td>Hz<\/td><td>50 \/ 60<\/td><\/tr>\n              <tr><td>3<\/td><td>Rated current<\/td><td>A<\/td><td>1250 \/ 1600 \/ 2000 \/ 2500<\/td><\/tr>\n              <tr><td>4<\/td><td>Power-frequency withstand voltage (1 min, phase-to-phase \/ to earth)<\/td><td>kV<\/td><td>95<\/td><\/tr>\n              <tr><td>5<\/td><td>Lightning impulse withstand voltage (peak)<\/td><td>kV<\/td><td>185<\/td><\/tr>\n              <tr><td>6<\/td><td>Rated short-circuit breaking current<\/td><td>kA<\/td><td>25 \/ 31.5<\/td><\/tr>\n              <tr><td>7<\/td><td>Rated short-time withstand current (4s)<\/td><td>kA<\/td><td>25 \/ 31.5<\/td><\/tr>\n              <tr><td>8<\/td><td>Rated short-circuit making current (peak)<\/td><td>kA<\/td><td>63 \/ 80<\/td><\/tr>\n              <tr><td>9<\/td><td>Mechanical life<\/td><td>operations<\/td><td>10,000<\/td><\/tr>\n              <tr><td>10<\/td><td>Rated operating sequence<\/td><td>\u2014<\/td><td>O \u2013 0.3s \u2013 CO \u2013 180s \u2013 CO<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n\n        <!-- 40.5kV Dimensions + drawing -->\n        <p class=\"block-title\">Outline &amp; mounting dimensions \u2014 ZW32-40.5<\/p>\n        <p class=\"block-note\">\n          Outline and mounting dimensions for typical 40.5kV ZW32 installation.\n        <\/p>\n        <div class=\"dim-block\">\n          <figure class=\"dim-fig\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/XBRELE-ZW32-40.5-Vacuum-circuit-breaker-installing-dimension.webp\"\n                 alt=\"ZW32-40.5 outline and mounting dimensions \u2013 XBRELE\">\n            <figcaption>ZW32-40.5 outline &amp; mounting dimensions for medium-voltage overhead line applications.<\/figcaption>\n          <\/figure>\n\n          <div class=\"dim-right\">\n            <div class=\"table-wrap\">\n              <table>\n                <thead>\n                  <tr>\n                    <th>Item<\/th><th>Symbol<\/th><th>Value (mm)<\/th><th>Note<\/th>\n                  <\/tr>\n                <\/thead>\n                <tbody>\n                  <tr><td>Overall height<\/td><td>H<\/td><td>\u2014<\/td><td>Overall height of 40.5kV breaker<\/td><\/tr>\n                  <tr><td>Overall width<\/td><td>W<\/td><td>\u2014<\/td><td>Including phase spacing<\/td><\/tr>\n                  <tr><td>Mounting hole spacing (horizontal)<\/td><td>L1<\/td><td>\u2014<\/td><td>Base horizontal bolt distance<\/td><\/tr>\n                  <tr><td>Mounting hole spacing (vertical)<\/td><td>L2<\/td><td>\u2014<\/td><td>To match steel structure or frame<\/td><\/tr>\n                  <tr><td>Mounting hole size<\/td><td>\u03a6<\/td><td>\u2014<\/td><td>Oval or round hole diameter<\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/div>\n\n            <div class=\"cta-right-col\">\n              <a href=\"#ct-popup-882\" class=\"cta-btn\">\n                Request a Quote from XBRELE\n              <\/a>\n            <\/div>\n          <\/div>\n        <\/div>\n\n      <\/div><!-- \/panel-card -->\n    <\/div><!-- \/zw32-40 -->\n\n  <\/div>\n\n  <script>\n    (function(){\n      const root = document.querySelector('#sec3-zw32-tech');\n      if(!root) return;\n      const tabs = root.querySelectorAll('.tab-btn');\n      const panels = root.querySelectorAll('.tab-content');\n\n      tabs.forEach(tab => {\n        tab.addEventListener('click', () => {\n          const target = tab.getAttribute('data-tab');\n          tabs.forEach(t => t.classList.remove('active'));\n          panels.forEach(p => p.classList.remove('active'));\n          tab.classList.add('active');\n          root.querySelector('#'+target).classList.add('active');\n        });\n      });\n    })();\n  <\/script>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-6ef4214\" data-block-id=\"6ef4214\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-6ef4214-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-47d26cc\" data-v=\"4\" data-block-id=\"47d26cc\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-47d26cc-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-47d26cc-inner-blocks\">\n<section id=\"sec4-zw32-features\" style=\"background:#ffffff;padding:90px 0 100px;\">\n  <style>\n    #sec4-zw32-features{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec4-zw32-features .features-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec4-zw32-features .sec-header{\n      max-width:820px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec4-zw32-features .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec4-zw32-features h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec4-zw32-features .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec4-zw32-features .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n    }\n    #sec4-zw32-features .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:22px 22px 24px;\n      box-shadow:0 14px 32px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n    #sec4-zw32-features .card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#0F172A;\n    }\n    #sec4-zw32-features .card .tag{\n      display:inline-flex;\n      align-items:center;\n      justify-content:flex-start;\n      padding:3px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      background:#0F172A;\n      color:#E5E7EB;\n      margin-bottom:12px;\n    }\n    #sec4-zw32-features .card p{\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n      margin:0 0 10px;\n    }\n    #sec4-zw32-features .card ul{\n      list-style:none;\n      padding:0;\n      margin:6px 0 0;\n      font-size:14px;\n      color:#374151;\n    }\n    #sec4-zw32-features .card li{\n      position:relative;\n      padding-left:16px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec4-zw32-features .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    @media(max-width:1000px){\n      #sec4-zw32-features .grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:690px){\n      #sec4-zw32-features .features-shell{padding:0 18px;}\n      #sec4-zw32-features .grid{\n        grid-template-columns:1fr;\n      }\n      #sec4-zw32-features h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"features-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Configuration &amp; options<\/div>\n      <h2>Protection, control and automation around the ZW32 series<\/h2>\n      <p>\n        ZW32 outdoor vacuum circuit breakers can be combined with protection relays, CTs\/VTs and\n        communication devices to form complete pole-mounted switching and automation solutions\n        for distribution networks.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- Card 1 -->\n      <article class=\"card\">\n        <span class=\"tag\">Protection<\/span>\n        <h3>Protection &amp; measuring combinations<\/h3>\n        <p>\n          Build a complete protection scheme around the ZW32 using your preferred relays\n          and instrument transformers.\n        <\/p>\n        <ul>\n          <li>Feeder over-current and earth-fault protection<\/li>\n          <li>Directional \/ non-directional protection according to system design<\/li>\n          <li>Integrated CTs for metering and protection functions<\/li>\n          <li>Support for recloser curves and sectionalizing logic<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2 -->\n      <article class=\"card\">\n        <span class=\"tag\">Control<\/span>\n        <h3>Operating &amp; control options<\/h3>\n        <p>\n          Flexible operating configurations to match manual, local and remote control requirements.\n        <\/p>\n        <ul>\n          <li>Spring operating mechanism with motor charging<\/li>\n          <li>Local\/remote control selector with clear position indication<\/li>\n          <li>AUX contacts for SCADA status feedback (open\/close\/ready)<\/li>\n          <li>Compatible with pole-mounted control cabinets and RTUs<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3 -->\n      <article class=\"card\">\n        <span class=\"tag\">Automation<\/span>\n        <h3>Distribution automation &amp; communication<\/h3>\n        <p>\n          When combined with suitable controllers, ZW32 breakers can be used in\n          automated distribution systems and smart grid projects.\n        <\/p>\n        <ul>\n          <li>Support for common protocols via external IEDs (Modbus, IEC 60870-5-104, etc.)<\/li>\n          <li>Remote open\/close and status monitoring through SCADA<\/li>\n          <li>Fault location, isolation and service restoration (FLISR) schemes<\/li>\n          <li>Customized wiring and terminal arrangements on request<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-8a0c640\" data-block-id=\"8a0c640\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-8a0c640-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-a0dbccf\" data-v=\"4\" data-block-id=\"a0dbccf\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-a0dbccf-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-a0dbccf-inner-blocks\">\n<section id=\"sec5-zw32-quality\" style=\"background:#0B1220;padding:72px 0 78px;color:#E5E7EB;\">\n  <style>\n    #sec5-zw32-quality{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec5-zw32-quality .quality-shell{\n      max-width:1500px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec5-zw32-quality .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec5-zw32-quality .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec5-zw32-quality h2{\n      font-size:26px;\n      margin:0 0 8px;\n      color:#F9FAFB;\n    }\n    #sec5-zw32-quality .sec-header p{\n      margin:0;\n      font-size:14px;\n      color:#CBD5F5;\n      line-height:1.7;\n    }\n\n    #sec5-zw32-quality .grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.2fr) minmax(0,1.05fr);\n      gap:28px;\n      align-items:flex-start;\n    }\n\n    \/* Left: process steps *\/\n    #sec5-zw32-quality .process-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:radial-gradient(circle at top left,rgba(56,189,248,.14) 0,rgba(15,23,42,.98) 36%,#020617 100%);\n      padding:22px 22px 24px;\n      box-shadow:0 22px 52px rgba(15,23,42,.9);\n    }\n    #sec5-zw32-quality .process-card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#E5F0FF;\n    }\n    #sec5-zw32-quality .process-card p{\n      font-size:13.5px;\n      color:#CBD5F5;\n      line-height:1.75;\n      margin:0 0 14px;\n    }\n    #sec5-zw32-quality .step-list{\n      list-style:none;\n      margin:0;\n      padding:0;\n      display:flex;\n      flex-direction:column;\n      gap:10px;\n    }\n    #sec5-zw32-quality .step{\n      display:grid;\n      grid-template-columns:auto minmax(0,1fr);\n      gap:8px 12px;\n      align-items:flex-start;\n    }\n    #sec5-zw32-quality .step-badge{\n      width:24px;\n      height:24px;\n      border-radius:999px;\n      border:1px solid rgba(148,163,184,.7);\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      font-size:11px;\n      font-weight:600;\n      color:#E5E7EB;\n      background:rgba(15,23,42,.85);\n      flex-shrink:0;\n    }\n    #sec5-zw32-quality .step h4{\n      font-size:13.5px;\n      margin:1px 0 3px;\n      color:#F9FAFB;\n    }\n    #sec5-zw32-quality .step p{\n      font-size:12.5px;\n      margin:0;\n      color:#CBD5F5;\n      line-height:1.7;\n    }\n\n    \/* Right: compact QA block *\/\n    #sec5-zw32-quality .qa-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:rgba(15,23,42,.96);\n      padding:20px 20px 22px;\n      box-shadow:0 22px 52px rgba(15,23,42,.8);\n    }\n    #sec5-zw32-quality .qa-section{\n      & {}\n    }\n    #sec5-zw32-quality .qa-label{\n      font-size:11px;\n      letter-spacing:.14em;\n      text-transform:uppercase;\n      color:#93C5FD;\n      margin-bottom:3px;\n    }\n    #sec5-zw32-quality .qa-card h3{\n      font-size:15px;\n      margin:0 0 4px;\n      color:#E5F0FF;\n    }\n    #sec5-zw32-quality .qa-card p{\n      font-size:13px;\n      color:#CBD5F5;\n      margin:0 0 4px;\n      line-height:1.65;\n    }\n    #sec5-zw32-quality .qa-block{\n      margin-top:10px;\n      padding-top:10px;\n      border-top:1px solid rgba(148,163,184,.35);\n    }\n    #sec5-zw32-quality .qa-block:first-of-type{\n      margin-top:6px;\n      padding-top:0;\n      border-top:none;\n    }\n    #sec5-zw32-quality .qa-block h4{\n      font-size:13.5px;\n      margin:0 0 3px;\n      color:#E5F0FF;\n    }\n    #sec5-zw32-quality .qa-block ul{\n      list-style:none;\n      padding:0;\n      margin:0;\n      font-size:12.5px;\n      color:#E5E7EB;\n    }\n    #sec5-zw32-quality .qa-block li{\n      position:relative;\n      padding-left:12px;\n      margin-bottom:2px;\n      line-height:1.6;\n    }\n    #sec5-zw32-quality .qa-block li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:7px;\n      width:5px;\n      height:5px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n    #sec5-zw32-quality .qa-note{\n      font-size:12px;\n      color:#9CA3AF;\n      margin-top:4px;\n    }\n\n    @media(max-width:1000px){\n      #sec5-zw32-quality .grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec5-zw32-quality .quality-shell{padding:0 18px;}\n      #sec5-zw32-quality h2{font-size:22px;}\n    }\n  <\/style>\n\n  <div class=\"quality-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Manufacturing &amp; quality control<\/div>\n      <h2>How XBRELE builds reliable ZW32 outdoor vacuum circuit breakers<\/h2>\n      <p>\n        Behind every ZW32 unit there is a controlled manufacturing flow \u2013 from embedded pole casting\n        to routine testing \u2013 designed to ensure long-term reliability on harsh outdoor lines.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- LEFT: process flow -->\n      <article class=\"process-card\">\n        <h3>From embedded pole to finished breaker<\/h3>\n        <p>\n          XBRELE manufactures the vacuum interrupter pole assemblies, operating mechanism and housing\n          in a coordinated process. Each step is monitored and recorded for traceability of every ZW32 unit.\n        <\/p>\n\n        <ul class=\"step-list\">\n          <li class=\"step\">\n            <div class=\"step-badge\">01<\/div>\n            <div>\n              <h4>Vacuum interrupter &amp; pole assembly<\/h4>\n              <p>Vacuum interrupters are checked for stroke, over-travel and resistance, then built into the solid pole.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">02<\/div>\n            <div>\n              <h4>Solid insulation casting &amp; curing<\/h4>\n              <p>Epoxy insulation is degassed, poured and cured to form a compact embedded pole resistant to tracking.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">03<\/div>\n            <div>\n              <h4>Mechanism integration &amp; adjustment<\/h4>\n              <p>The spring mechanism is assembled, lubricated and tuned so speeds, timing and bounce meet ZW32 limits.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">04<\/div>\n            <div>\n              <h4>Final assembly &amp; sealing<\/h4>\n              <p>Poles, CTs, terminals and enclosure parts are combined into a sealed outdoor body with anti-corrosion coating.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">05<\/div>\n            <div>\n              <h4>Routine testing &amp; inspection<\/h4>\n              <p>Each breaker passes electrical, mechanical and dielectric tests before packing and shipment.<\/p>\n            <\/div>\n          <\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- RIGHT: compact QA -->\n      <section class=\"qa-card\">\n        <div class=\"qa-section\">\n          <div class=\"qa-label\">Electrical &amp; dielectric tests<\/div>\n          <h3>Routine tests for every ZW32<\/h3>\n          <p>Electrical routine tests verify insulation level and switching performance.<\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Insulation &amp; switching verification<\/h4>\n          <ul>\n            <li>Power-frequency withstand between phases and to earth<\/li>\n            <li>Lightning impulse withstand on sample basis<\/li>\n            <li>Contact resistance check for each main circuit<\/li>\n            <li>Mechanical operating tests for O \/ CO sequences<\/li>\n          <\/ul>\n          <p class=\"qa-note\">Routine-test records can be supplied with the shipment if required.<\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Mechanical reliability<\/h4>\n          <ul>\n            <li>Type-test verification of 10,000 mechanical operations<\/li>\n            <li>Check of opening \/ closing speeds within limits<\/li>\n            <li>Control of closing bounce time and pole synchronism<\/li>\n            <li>Environmental checks for lubrication and low-temperature duty<\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Documentation &amp; traceability<\/h4>\n          <ul>\n            <li>Type-test reports and routine-test certificates<\/li>\n            <li>Factory inspection records with serial number traceability<\/li>\n            <li>Outline drawings &amp; terminal diagrams in editable format<\/li>\n            <li>Recommended maintenance guidelines for field crews<\/li>\n          <\/ul>\n          <p class=\"qa-note\">FAT \/ QAP \/ ITP witness testing can be arranged for utility or EPC projects.<\/p>\n        <\/div>\n      <\/section>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-2494b82\" data-block-id=\"2494b82\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-2494b82-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-cffea66\" data-v=\"4\" data-block-id=\"cffea66\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-cffea66-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-cffea66-inner-blocks\">\n<section id=\"sec6-zw32-delivery\" style=\"background:#F9FAFB;padding:88px 0 96px;\">\n  <style>\n    #sec6-zw32-delivery{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec6-zw32-delivery .delivery-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec6-zw32-delivery .sec-header{\n      max-width:860px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec6-zw32-delivery .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec6-zw32-delivery h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec6-zw32-delivery .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec6-zw32-delivery .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n      align-items:stretch;\n    }\n    #sec6-zw32-delivery .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:20px 20px 22px;\n      box-shadow:0 16px 34px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n    #sec6-zw32-delivery .card-label{\n      font-size:11px;\n      letter-spacing:.14em;\n      text-transform:uppercase;\n      color:#6B7280;\n      margin-bottom:6px;\n    }\n    #sec6-zw32-delivery .card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#0F172A;\n    }\n    #sec6-zw32-delivery .card p{\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n      margin:0 0 10px;\n    }\n    #sec6-zw32-delivery .card ul{\n      list-style:none;\n      padding:0;\n      margin:4px 0 0;\n      font-size:13.5px;\n      color:#374151;\n    }\n    #sec6-zw32-delivery .card li{\n      position:relative;\n      padding-left:14px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec6-zw32-delivery .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:7px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    #sec6-zw32-delivery .cta-row{\n      margin-top:32px;\n      display:flex;\n      justify-content:center;\n    }\n    #sec6-zw32-delivery .cta-btn{\n      display:inline-block;\n      padding:11px 30px;\n      border-radius:8px;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:15px;\n      font-weight:600;\n      text-decoration:none;\n      letter-spacing:.03em;\n      box-shadow:0 12px 28px rgba(15,23,42,.2);\n      transition:all .25s ease;\n      white-space:nowrap;\n    }\n    #sec6-zw32-delivery .cta-btn:hover{\n      background:#1F2937;\n      box-shadow:0 16px 32px rgba(15,23,42,.28);\n      transform:translateY(-1px);\n    }\n\n    @media(max-width:1000px){\n      #sec6-zw32-delivery .grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:690px){\n      #sec6-zw32-delivery .delivery-shell{padding:0 18px;}\n      #sec6-zw32-delivery .grid{\n        grid-template-columns:1fr;\n      }\n      #sec6-zw32-delivery h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"delivery-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Delivery &amp; project support<\/div>\n      <h2>Lead time, export packing and engineering support for ZW32 projects<\/h2>\n      <p>\n        XBRELE supports utilities, EPC contractors and distributors with predictable delivery, export-ready\n        packing and engineering documentation for ZW32 outdoor vacuum circuit breakers at 12&nbsp;kV and 40.5&nbsp;kV.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- Card 1: Lead time -->\n      <article class=\"card\">\n        <div class=\"card-label\">Lead time<\/div>\n        <h3>Standard &amp; project delivery<\/h3>\n        <p>\n          Typical delivery times for ZW32 breakers, depending on configuration and quantity.\n        <\/p>\n        <ul>\n          <li>Standard 12&nbsp;kV \/ 40.5&nbsp;kV ZW32: about 15\u201325 days after order confirmation<\/li>\n          <li>Projects with mixed ratings or accessories: usually 25\u201335 days<\/li>\n          <li>Urgent orders can be discussed case-by-case according to production load<\/li>\n          <li>Sample units available on request for type checking and approvals<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2: Packing & logistics -->\n      <article class=\"card\">\n        <div class=\"card-label\">Export packing &amp; logistics<\/div>\n        <h3>Seaworthy packing &amp; flexible shipment<\/h3>\n        <p>\n          ZW32 breakers are packed for long-distance sea or land transportation with proper protection.\n        <\/p>\n        <ul>\n          <li>Individual breaker packed in export carton or wooden case with shock protection<\/li>\n          <li>Moisture-protection and anti-rust treatment for outdoor installation parts<\/li>\n          <li>Suitable for mixed containers with other XBRELE switchgear and transformers<\/li>\n          <li>FOB Ningbo \/ Shanghai, CIF or other Incoterms can be supported according to the contract<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3: Project support -->\n      <article class=\"card\">\n        <div class=\"card-label\">Project support<\/div>\n        <h3>Documentation &amp; engineering assistance<\/h3>\n        <p>\n          XBRELE provides the documentation and technical support needed for network planning and project approval.\n        <\/p>\n        <ul>\n          <li>Outline drawings, terminal diagrams and foundation details for ZW32<\/li>\n          <li>Type-test reports, routine-test certificates and factory inspection records<\/li>\n          <li>QAP \/ ITP preparation and FAT witness testing for utility &amp; EPC projects<\/li>\n          <li>Support with selection of ratings and configuration for specific overhead line schemes<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n\n    <div class=\"cta-row\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Discuss Your ZW32 Project with XBRELE\n      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-0153ae1\" data-block-id=\"0153ae1\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-0153ae1-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-5cc1124\" data-v=\"4\" data-block-id=\"5cc1124\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-5cc1124-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-5cc1124-inner-blocks\">\n<section id=\"sec7-zw32-faq\" style=\"padding:90px 0 110px;background:#ffffff;\">\n  <style>\n    #sec7-zw32-faq{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec7-zw32-faq .faq-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec7-zw32-faq .faq-header{\n      max-width:780px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec7-zw32-faq .faq-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec7-zw32-faq h2{\n      font-size:28px;\n      margin:0 0 12px;\n      color:#0F172A;\n    }\n    #sec7-zw32-faq .faq-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec7-zw32-faq .faq-grid{\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:18px 26px;\n      align-items:flex-start;\n    }\n\n    #sec7-zw32-faq details{\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:14px 16px;\n      transition:box-shadow .2s ease, border-color .2s ease, background .2s ease;\n    }\n    #sec7-zw32-faq details[open]{\n      background:#FFFFFF;\n      border-color:#CBD5F5;\n      box-shadow:0 12px 30px rgba(15,23,42,.06);\n    }\n    #sec7-zw32-faq summary{\n      list-style:none;\n      cursor:pointer;\n      font-size:15px;\n      font-weight:600;\n      color:#111827;\n      display:flex;\n      align-items:flex-start;\n      justify-content:space-between;\n      gap:10px;\n    }\n    #sec7-zw32-faq summary::-webkit-details-marker{display:none;}\n    #sec7-zw32-faq .faq-icon{\n      flex-shrink:0;\n      width:18px;\n      height:18px;\n      border-radius:999px;\n      border:1px solid #D1D5DB;\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      font-size:11px;\n      color:#6B7280;\n      margin-top:2px;\n    }\n    #sec7-zw32-faq details[open] .faq-icon{\n      background:#2563EB;\n      color:#FFFFFF;\n      border-color:#2563EB;\n    }\n    #sec7-zw32-faq .faq-answer{\n      margin-top:10px;\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n    #sec7-zw32-faq .faq-answer a{\n      color:#2563EB;\n      text-decoration:none;\n    }\n    #sec7-zw32-faq .faq-answer a:hover{\n      text-decoration:underline;\n    }\n\n    @media(max-width:1000px){\n      #sec7-zw32-faq .faq-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec7-zw32-faq .faq-shell{padding:0 18px;}\n      #sec7-zw32-faq h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"faq-shell\">\n    <div class=\"faq-header\">\n      <div class=\"faq-kicker\">FAQ \u00b7 ZW32 Series<\/div>\n      <h2>Frequently asked questions about ZW32 outdoor vacuum circuit breakers<\/h2>\n      <p>Below are some typical questions from utilities, EPC contractors and distributors when selecting\n        XBRELE ZW32 vacuum circuit breakers for 12kV and 40.5kV overhead lines.<\/p>\n    <\/div>\n\n    <div class=\"faq-grid\">\n      <!-- Q1 -->\n      <details open>\n        <summary>\n          <span>What is the difference between ZW32-12 and ZW32-40.5?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          ZW32-12 is designed for 12&nbsp;kV distribution networks, while ZW32-40.5 supports 40.5&nbsp;kV\n          overhead systems with higher insulation and short-circuit ratings. Both use embedded poles and\n          vacuum interrupters, but the 40.5&nbsp;kV version features higher Basic Insulation Level (BIL),\n          higher breaking capacity and larger overall dimensions to meet medium-voltage requirements.\n        <\/div>\n      <\/details>\n\n      <!-- Q2 -->\n      <details>\n        <summary>\n          <span>Does the ZW32 series support automatic reclosing functions?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Yes. XBRELE supplies ZW32 automatic recloser configurations with matched controller, auxiliary\n          CTs and wiring. The controller can be programmed with reclosing sequences, protection curves and\n          remote communication. Standard ZW32 breakers can also be combined with third-party feeder\n          automation controllers if required by the project.\n        <\/div>\n      <\/details>\n\n      <!-- Q3 -->\n      <details>\n        <summary>\n          <span>Can ZW32 be installed on concrete poles or steel cross-arms?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Yes. The ZW32 mounting base allows installation on steel cross-arms, concrete poles and lattice\n          structures. Designers can refer to the outline &amp; mounting dimensions (H, W, L1, L2 and\n          mounting hole size) provided in this page to match the support structure and hardware.\n        <\/div>\n      <\/details>\n\n      <!-- Q4 -->\n      <details>\n        <summary>\n          <span>What routine tests are performed before shipment?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Every ZW32 breaker is 100% routine-tested at the factory. Tests typically include power-frequency\n          withstand between phases and to earth, lightning impulse withstand on a sample basis, contact\n          resistance measurement of each main circuit, mechanical operating tests for O \/ CO sequences, and\n          visual checks of sealing, wiring and markings. Routine-test records can be supplied with the\n          shipment when required.\n        <\/div>\n      <\/details>\n\n      <!-- Q5 -->\n      <details>\n        <summary>\n          <span>Can XBRELE provide drawings and documentation for project approval?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Yes. XBRELE can support customers with outline drawings, terminal diagrams, type-test\n          certificates, routine-test reports and factory inspection records. For utility and EPC projects,\n          we can also provide QAP\/ITP documents and support FAT witness testing according to the project\n          specification.\n        <\/div>\n      <\/details>\n\n      <!-- Q6 -->\n      <details>\n        <summary>\n          <span>What is the typical delivery time for ZW32 outdoor vacuum circuit breakers?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          For standard 12&nbsp;kV and 40.5&nbsp;kV ZW32 configurations, the typical lead time is about\n          15\u201325 days after order confirmation. For customized breakers with special accessories, controllers\n          or testing requirements, lead time is normally 25\u201335 days depending on quantity and project scope.\n        <\/div>\n      <\/details>\n\n      <!-- Q7 \u00b7 \u5e26 external link -->\n      <details>\n        <summary>\n          <span>Which international standards does the ZW32 series comply with?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          ZW32 outdoor vacuum circuit breakers are designed and type tested with reference to the IEC&nbsp;62271\n          series for high-voltage switchgear, in particular IEC&nbsp;62271-100 for high-voltage AC circuit-breakers.\n          For more information about the scope and latest edition of IEC&nbsp;62271-100, you can refer to the\n          official IEC webstore page\n          <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"nofollow noopener\">\n            IEC 62271-100\n          <\/a>.\n        <\/div>\n      <\/details>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Vacuum Circuit Breakers \u00b7 Series ZW32 Vacuum Circuit Breaker Series ZW32 series outdoor vacuum circuit breakers are widely used on 12kV and 40.5kV distribution networks. The unit integrates vacuum interrupter, solid-insulated embedded pole, operating mechanism and current transformer, offering reliable breaking performance for overhead lines, ring main systems and compact substations. 12kV 40.5kV Outdoor Pole-mounted [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1071,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1107","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","content_style_source":"inherit","vertical_spacing_source":"custom","content_area_spacing":"bottom","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/pages\/1107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/comments?post=1107"}],"version-history":[{"count":14,"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/pages\/1107\/revisions"}],"predecessor-version":[{"id":1148,"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/pages\/1107\/revisions\/1148"}],"up":[{"embeddable":true,"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/pages\/1071"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/de\/wp-json\/wp\/v2\/media?parent=1107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}