{"id":1965,"date":"2025-12-04T13:54:12","date_gmt":"2025-12-04T13:54:12","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1965"},"modified":"2025-12-04T15:31:46","modified_gmt":"2025-12-04T15:31:46","slug":"distribution-transformer-manufacturer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/es\/distribution-transformer-manufacturer\/","title":{"rendered":"Fabricante de transformadores de distribuci\u00f3n"},"content":{"rendered":"<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-8c2e1dd\" data-block-id=\"8c2e1dd\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-8c2e1dd-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-c9c3a9e\" data-v=\"4\" data-block-id=\"c9c3a9e\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-c9c3a9e-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-c9c3a9e-inner-blocks\">\n<style>\n    \/* --- XBRELE PRO STYLE SYSTEM (v5.1 - Transformer Edition) --- *\/\n    \n    .xbrele-pro-page {\n        font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        color: #111;\n        line-height: 1.7; \n        font-size: 18px; \n        font-weight: 400;\n        background-color: #fff;\n    }\n\n    .xbrele-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        padding: 0 20px;\n    }\n\n    .xbrele-section {\n        padding: 60px 0;\n        border-bottom: 1px solid #f0f0f0;\n    }\n    .xbrele-section.bg-light {\n        background-color: #f8fbfb;\n    }\n\n    .xbrele-pro-page h1 {\n        font-size: 42px;\n        font-weight: 800;\n        text-align: center;\n        margin-bottom: 30px;\n        color: #000;\n        letter-spacing: -0.5px;\n    }\n    \n    .xbrele-pro-page h2 {\n        font-size: 30px;\n        color: #000;\n        margin-top: 50px;\n        margin-bottom: 25px;\n        position: relative;\n        padding-left: 20px;\n        border-left: 8px solid #009688; \/* XBRELE Teal *\/\n        font-weight: 700;\n        text-transform: uppercase;\n    }\n    \n    .xbrele-pro-page h3 {\n        font-size: 22px;\n        font-weight: 700;\n        margin-top: 35px;\n        margin-bottom: 15px;\n        color: #009688;\n    }\n\n    .xbrele-pro-page p {\n        margin-bottom: 25px;\n        color: #222;\n        text-align: justify;\n    }\n\n    \/* Hero \u56fe\u7247\u6837\u5f0f *\/\n    .xbrele-hero-img {\n        width: 100%;\n        height: auto;\n        border-radius: 6px;\n        margin-bottom: 40px;\n        box-shadow: 0 4px 12px rgba(0,0,0,0.1);\n        display: block;\n    }\n\n    .xbrele-list {\n        list-style: none;\n        padding: 0;\n        margin-bottom: 30px;\n    }\n    .xbrele-list li {\n        position: relative;\n        padding-left: 30px;\n        margin-bottom: 12px;\n        color: #222;\n    }\n    .xbrele-list li::before {\n        content: \"\u25a0\";\n        position: absolute;\n        left: 0;\n        color: #009688;\n        font-size: 14px;\n        top: 6px;\n    }\n\n    .xbrele-tech-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 40px 0;\n        box-shadow: 0 5px 15px rgba(0,0,0,0.05);\n        font-size: 16px;\n    }\n    .xbrele-tech-table th, .xbrele-tech-table td {\n        padding: 18px;\n        border: 1px solid #ddd;\n    }\n    .xbrele-tech-table th {\n        background-color: #009688;\n        color: #fff;\n        font-weight: 700;\n        text-align: left;\n    }\n    .xbrele-tech-table tr:nth-child(even) {\n        background-color: #fcfcfc;\n    }\n\n    .xbrele-link {\n        color: #009688;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid rgba(0,150,136,0.2);\n        transition: all 0.2s;\n    }\n    .xbrele-link:hover {\n        background-color: rgba(0,150,136,0.1);\n        border-bottom-color: #009688;\n    }\n\n    .xbrele-ext-link {\n        color: #555;\n        text-decoration: underline;\n        font-style: italic;\n    }\n\n    .xbrele-cta-box {\n        background: linear-gradient(135deg, #009688 0%, #004d40 100%);\n        color: #fff;\n        padding: 60px;\n        border-radius: 8px;\n        text-align: center;\n        margin-top: 60px;\n    }\n    .xbrele-cta-btn {\n        display: inline-block;\n        background-color: #fff;\n        color: #009688 !important;\n        padding: 18px 45px;\n        font-weight: 800;\n        text-transform: uppercase;\n        border-radius: 4px;\n        text-decoration: none;\n        margin-top: 25px;\n        font-size: 18px;\n        box-shadow: 0 4px 6px rgba(0,0,0,0.2);\n    }\n    .xbrele-cta-btn:hover {\n        background-color: #f4f4f4;\n        transform: translateY(-2px);\n    }\n<\/style>\n\n<div class=\"xbrele-pro-page\">\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h1>Fabricante de transformadores de distribuci\u00f3n y soluciones OEM<\/h1>\n            \n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-manufacturing-factory-workshop.webp\" \n                 alt=\"Fabricante de transformadores de distribuci\u00f3n XBRELE F\u00e1brica que produce transformadores de tipo seco y sumergidos en aceite\" \n                 class=\"xbrele-hero-img\" \/>\n\n            <p>\n                La fabricaci\u00f3n de transformadores de distribuci\u00f3n es la columna vertebral de la red el\u00e9ctrica, responsable de reducir la tensi\u00f3n media (6 kV-35 kV) a niveles de baja tensi\u00f3n utilizables. Implica dos tecnolog\u00edas distintas: <strong>Inmerso en aceite<\/strong> transformadores (rellenos de l\u00edquido) para uso en exteriores en servicios p\u00fablicos y <strong>Tipo seco<\/strong> (resina moldeada) para la seguridad comercial en interiores. Como especialista <strong>Fabricante de transformadores de distribuci\u00f3n<\/strong>, XBRELE opera una planta de producci\u00f3n dual capaz de fabricar unidades de alta eficiencia que cumplen con las normas IEC 60076. Tanto si necesita un producto resistente <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/oil-immersed-transformer\/\" class=\"xbrele-link\">Transformador de aceite S13<\/a> para una red rural o una red resistente al fuego <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/dry-type-transformer\/\" class=\"xbrele-link\">Transformador de resina moldeada SCB<\/a> Para edificios de gran altura, XBRELE ofrece fabricaci\u00f3n OEM centrada en bajas p\u00e9rdidas y larga vida \u00fatil.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Proceso de fabricaci\u00f3n de transformadores<\/h2>\n            <p>\n                El proceso de fabricaci\u00f3n de transformadores es complejo e implica un dise\u00f1o electromagn\u00e9tico preciso y una ingenier\u00eda de aislamiento. En XBRELE, seguimos un estricto protocolo de calidad tanto para nuestra l\u00ednea de productos secos como para la de productos en aceite.\n            <\/p>\n            <p>\n                <strong>Apilamiento central (tecnolog\u00eda Step-Lap):<\/strong> El coraz\u00f3n del transformador es el n\u00facleo de hierro. Utilizamos acero el\u00e9ctrico de grano orientado (GOES) de alta permeabilidad. Nuestros n\u00facleos se cortan y apilan utilizando la tecnolog\u00eda \u201cStep-Lap\u201d, que reduce la brecha de flujo magn\u00e9tico en las juntas. Esto reduce significativamente la p\u00e9rdida sin carga y los niveles de ruido, un factor cr\u00edtico para las redes ecol\u00f3gicas modernas.\n            <\/p>\n            <p>\n                <strong>Bobinado (tecnolog\u00eda de l\u00e1minas):<\/strong> Para las bobinas de baja tensi\u00f3n (LV), XBRELE utiliza <strong>Enrollado autom\u00e1tico de l\u00e1minas<\/strong> en lugar del bobinado tradicional con alambre. Esta t\u00e9cnica utiliza l\u00e1minas de cobre o aluminio, lo que elimina el \u00e1ngulo de h\u00e9lice y reduce las fuerzas axiales de cortocircuito. Esto garantiza que el transformador pueda soportar corrientes de fallo repentinas sin sufrir deformaciones mec\u00e1nicas.\n            <\/p>\n            <p>\n                <strong>Moldeo al vac\u00edo (tipo seco):<\/strong> En nuestra serie SCB, las bobinas se colocan en un tanque de fundici\u00f3n al vac\u00edo. La resina epoxi se vierte al vac\u00edo para garantizar una impregnaci\u00f3n profunda. Esto elimina las burbujas de aire que podr\u00edan causar descargas parciales (PD), lo que garantiza que el aislamiento dure d\u00e9cadas.\n            <\/p>\n            <p>\n                <strong>Secado al vac\u00edo y llenado de aceite (tipo aceite):<\/strong> En nuestra serie S13, la parte activa se seca en una planta de secado en fase vapor de queroseno para eliminar toda la humedad. A continuaci\u00f3n, el dep\u00f3sito se llena con aceite mineral desgasificado al vac\u00edo, lo que garantiza una resistencia aislante perfecta.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Materias primas utilizadas en la producci\u00f3n de transformadores<\/h2>\n            <p>\n                La calidad de un transformador depende de la calidad de sus materiales. XBRELE utiliza materias primas de primera calidad para garantizar una alta eficiencia (bajas p\u00e9rdidas por I\u00b2R e hist\u00e9resis).\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>L\u00e1minas de acero al silicio:<\/strong> Nos abastecemos de acero al silicio de grano orientado de grado Hi-B de las mejores acer\u00edas (como Baosteel). Para nuestro <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/amorphous-alloy-transformer\/\" class=\"xbrele-link\">Transformadores de aleaci\u00f3n amorfa<\/a>, Utilizamos cintas met\u00e1licas amorfas avanzadas que reducen las p\u00e9rdidas en vac\u00edo hasta en un 75% en comparaci\u00f3n con el acero tradicional.<\/li>\n                <li><strong>Materiales conductores:<\/strong> Utilizamos cobre libre de ox\u00edgeno (OFC) o aluminio de grado el\u00e9ctrico para los devanados, seg\u00fan las especificaciones del cliente. La pureza garantiza una baja resistencia y una generaci\u00f3n de calor m\u00ednima.<\/li>\n                <li><strong>Resina epoxi (Clase F\/H):<\/strong> Para las unidades de tipo seco, utilizamos una mezcla epoxi especializada con relleno de s\u00edlice que proporciona una excelente disipaci\u00f3n del calor y resistencia al fuego (autoextinguible).<\/li>\n                <li><strong>Aceite mineral:<\/strong> Para las unidades sumergidas en aceite, utilizamos aceite para transformadores naft\u00e9nico o paraf\u00ednico de alta calidad con alta rigidez diel\u00e9ctrica (&gt;60 kV) y excelente estabilidad frente a la oxidaci\u00f3n.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Equipo esencial de fabricaci\u00f3n<\/h2>\n            <p>\n                La f\u00e1brica de XBRELE est\u00e1 equipada con maquinaria moderna dise\u00f1ada para garantizar la uniformidad en miles de unidades.\n            <\/p>\n            <p>\n                <strong>M\u00e1quinas autom\u00e1ticas para enrollar l\u00e1minas:<\/strong> Estas m\u00e1quinas controlan autom\u00e1ticamente la tensi\u00f3n y la alineaci\u00f3n, envolviendo simult\u00e1neamente el papel aislante y la l\u00e1mina conductora. Esto elimina el error humano y crea una bobina con alta resistencia mec\u00e1nica.\n            <\/p>\n            <p>\n                <strong>Planta de fundici\u00f3n al vac\u00edo:<\/strong> Nuestras c\u00e1maras est\u00e1ticas de mezcla y moldeo permiten un control preciso de la temperatura de la resina y los niveles de vac\u00edo, esenciales para producir \u201cPD-Free\u201d.\u201d <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/dry-type-transformer\/\" class=\"xbrele-link\">Transformadores de tipo seco<\/a>.\n            <\/p>\n            <p>\n                <strong>L\u00ednea de producci\u00f3n de tanques corrugados:<\/strong> Para los transformadores de aceite herm\u00e9ticamente sellados, fabricamos internamente los tanques con aletas corrugadas. Estas aletas se expanden y contraen con los cambios de temperatura del aceite, lo que elimina la necesidad de un tanque conservador y evita que el aire entre en contacto con el aceite.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Procedimientos de prueba para transformadores de distribuci\u00f3n<\/h2>\n            <p>\n                Las pruebas son fundamentales para verificar la eficiencia y la seguridad de un transformador. Todas las unidades XBRELE se someten a pruebas rutinarias de conformidad con la norma IEC 60076 antes de su env\u00edo.\n            <\/p>\n            \n            <table class=\"xbrele-tech-table\">\n                <tr>\n                    <th>Nombre de la prueba<\/th>\n                    <th>Tipo de producto<\/th>\n                    <th>Prop\u00f3sito<\/th>\n                <\/tr>\n                <tr>\n                    <td><strong>Prueba de grupo Ratio &amp; Vector<\/strong><\/td>\n                    <td>Todo<\/td>\n                    <td>Verifica la relaci\u00f3n de transformaci\u00f3n de tensi\u00f3n y la relaci\u00f3n de fase (por ejemplo, Dyn11).<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Resistencia al enrollamiento<\/strong><\/td>\n                    <td>Todo<\/td>\n                    <td>Comprueba si hay conexiones sueltas y verifica la calidad del cobre\/aluminio.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>P\u00e9rdida de carga e impedancia de tensi\u00f3n<\/strong><\/td>\n                    <td>Todo<\/td>\n                    <td>Mide la eficiencia bajo carga y verifica la impedancia de cortocircuito (Uk%).<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Prueba de tensi\u00f3n aplicada<\/strong><\/td>\n                    <td>Todo<\/td>\n                    <td>Verifica el nivel de aislamiento entre los devanados y tierra (resistencia a la frecuencia industrial).<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Descarga parcial (PD)<\/strong><\/td>\n                    <td>Tipo seco<\/td>\n                    <td>Garantiza que el aislamiento de resina moldeada no presente huecos (&lt; 10 pC).<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Prueba de presi\u00f3n de fuga de aceite<\/strong><\/td>\n                    <td>Tipo de aceite<\/td>\n                    <td>Presuriza el tanque para garantizar que las juntas sean herm\u00e9ticas y a prueba de fugas.<\/td>\n                <\/tr>\n            <\/table>\n            \n            <p>\n                Tambi\u00e9n realizamos pruebas de tipo (aumento de temperatura, impulso de rayo) en unidades prototipo para validar las capacidades t\u00e9rmicas y diel\u00e9ctricas del dise\u00f1o.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Por qu\u00e9 deber\u00eda trabajar con un fabricante de transformadores personalizados<\/h2>\n            <p>\n                Los requisitos de la red el\u00e9ctrica var\u00edan en todo el mundo. Un transformador est\u00e1ndar de 11 kV\/400 V para China podr\u00eda no funcionar para un proyecto en Filipinas (13,2 kV) o Sud\u00e1frica (11 kV\/415 V). XBRELE se especializa en <strong>Fabricaci\u00f3n de voltaje personalizado<\/strong>.\n            <\/p>\n            <p>\n                Podemos personalizar el <strong>Rango de pulsaci\u00f3n<\/strong> (por ejemplo, \u00b12\u00d72,5% o \u00b15%) y el <strong>Grupo Vector<\/strong> (Dyn11, Yyn0 o grupos industriales especiales). Para <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/dry-type-transformer\/\" class=\"xbrele-link\">Transformadores de tipo seco<\/a>, Ofrecemos clasificaciones IP personalizadas (IP20, IP23, IP44) para la carcasa, lo que permite su instalaci\u00f3n en entornos polvorientos o semiexteriores.\n            <\/p>\n            <p>\n                Nuestro equipo de ingenier\u00eda tambi\u00e9n dise\u00f1a transformadores con tensiones de impedancia espec\u00edficas (Uk%) para adaptarse a las unidades existentes para el funcionamiento en paralelo, un requisito crucial para las ampliaciones de las plantas.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Los fabricantes de transformadores de distribuci\u00f3n tienen experiencia.<\/h2>\n            <p>\n                La fabricaci\u00f3n de transformadores es una industria madura en la que la experiencia cuenta. XBRELE cuenta con d\u00e9cadas de experiencia en la optimizaci\u00f3n de dise\u00f1os de n\u00facleos para equilibrar el coste y la eficiencia. Entendemos las compensaciones entre la \u201cp\u00e9rdida sin carga\u201d (p\u00e9rdida de hierro) y la \u201cp\u00e9rdida con carga\u201d (p\u00e9rdida de cobre).\n            <\/p>\n            <p>\n                Nuestra experiencia con <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/amorphous-alloy-transformer\/\" class=\"xbrele-link\">Tecnolog\u00eda de aleaciones amorfas<\/a> Nos permite fabricar unidades de ultra alta eficiencia para proyectos modernos de energ\u00eda verde (parques solares\/e\u00f3licos), ayudando a los clientes a cumplir con estrictas directivas de eficiencia energ\u00e9tica (como las normas Tier 2 de la UE).\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Soluciones de fabricaci\u00f3n rentables<\/h2>\n            <p>\n                XBRELE ofrece una ventaja significativa en t\u00e9rminos de costes para las empresas de ingenier\u00eda, adquisici\u00f3n y construcci\u00f3n (EPC) y las empresas de servicios p\u00fablicos a nivel mundial. Con sede en China, tenemos acceso a una enorme cadena de suministro de acero el\u00e9ctrico y cobre.\n            <\/p>\n            <p>\n                Nuestro modelo \u201cdirecto de f\u00e1brica\u201d elimina los m\u00e1rgenes de los distribuidores. Adem\u00e1s, nuestro eficiente proceso de bobinado de l\u00e1minas reduce el tiempo de mano de obra y el desperdicio de material en comparaci\u00f3n con los antiguos m\u00e9todos de bobinado de alambre. Esto nos permite ofrecer unidades de altas prestaciones (por ejemplo, transformadores con factor K) a precios muy competitivos en licitaciones internacionales.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Capacidades de producci\u00f3n adaptables<\/h2>\n            <p>\n                XBRELE ofrece una amplia gama de productos bajo un mismo techo. Fabricamos productos est\u00e1ndar <strong>Transformadores montados en postes<\/strong> para distribuci\u00f3n a\u00e9rea y <strong>Montado sobre plataforma<\/strong> Unidades para sistemas subterr\u00e1neos.\n            <\/p>\n            <p>\n                Nos adaptamos a aplicaciones especiales. Producimos <strong>Transformadores rectificadores<\/strong> para la electr\u00f3lisis industrial, <strong>Transformadores para hornos<\/strong> para acer\u00edas, y <strong>Transformadores de aislamiento<\/strong> para centros de datos sensibles. Esta versatilidad permite a XBRELE actuar como socio integral en soluciones de energ\u00eda.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Pr\u00e1cticas de fabricaci\u00f3n sostenibles<\/h2>\n            <p>\n                Los transformadores son activos de larga duraci\u00f3n (20-30 a\u00f1os), por lo que la sostenibilidad es clave. XBRELE se centra en la producci\u00f3n de transformadores de \u201cdise\u00f1o ecol\u00f3gico\u201d con p\u00e9rdidas reducidas. Nuestro <a href=\"https:\/\/xbrele.com\/es\/power-distribution-transformers\/amorphous-alloy-transformer\/\" class=\"xbrele-link\">Serie de aleaciones amorfas<\/a> es un ejemplo perfecto, ya que reduce el consumo energ\u00e9tico en modo de espera hasta en un 75%.\n            <\/p>\n            <p>\n                En la fabricaci\u00f3n, utilizamos sistemas de manejo de aceite de circuito cerrado para evitar derrames y reciclar los residuos de cobre y acero. Nuestros transformadores de tipo seco son intr\u00ednsecamente ecol\u00f3gicos, ya que no contienen aceite y no presentan ning\u00fan riesgo de contaminaci\u00f3n del suelo, lo que los convierte en la opci\u00f3n preferida para las certificaciones de construcci\u00f3n sostenible (LEED\/BREEAM).\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Ventajas de la fabricaci\u00f3n de transformadores en China<\/h2>\n            <p>\n                China es el mayor productor mundial de transformadores de potencia. XBRELE aprovecha este ecosistema para ofrecer:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>Escala:<\/strong> Podemos producir cientos de unidades al mes, lo que nos permite apoyar proyectos de electrificaci\u00f3n rural a gran escala.<\/li>\n                <li><strong>Velocidad:<\/strong> Los transformadores de distribuci\u00f3n est\u00e1ndar de 11 kV suelen fabricarse en un plazo de entre 15 y 20 d\u00edas.<\/li>\n                <li><strong>Log\u00edstica:<\/strong> Tenemos experiencia en el env\u00edo de transformadores pesados, utilizando registradores de impactos y embalajes a prueba de humedad para garantizar que lleguen de forma segura a cualquier parte del mundo.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Encontrar el fabricante de transformadores adecuado<\/h2>\n            <p>\n                A la hora de seleccionar un proveedor, tenga en cuenta estos factores cr\u00edticos:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>Laboratorio de pruebas:<\/strong> \u00bfLa f\u00e1brica cuenta con capacidad de prueba verificada para sobretensi\u00f3n inducida y DP?<\/li>\n                <li><strong>Capacidad de dise\u00f1o:<\/strong> \u00bfPueden proporcionar planos CAD detallados y c\u00e1lculos t\u00e9rmicos antes de la producci\u00f3n?<\/li>\n                <li><strong>Garant\u00eda:<\/strong> Busque fabricantes que ofrezcan al menos una garant\u00eda de 24 meses, lo que demuestra su confianza en la calidad de sus productos.<\/li>\n                <li><strong>Referencias:<\/strong> Solicite una lista de referencias de proyectos en zonas clim\u00e1ticas similares (por ejemplo, tropicales o des\u00e9rticas).<\/li>\n            <\/ul>\n            <p>\n                XBRELE le invita a visitar nuestras instalaciones o solicitar una visita virtual para ver nuestro control de calidad en acci\u00f3n.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-container\">\n        <div class=\"xbrele-cta-box\">\n            <h2>Impulse su proyecto con los transformadores XBRELE<\/h2>\n            <p>Obtenga hoy mismo un presupuesto directo para transformadores de tipo seco, sumergidos en aceite o de aleaci\u00f3n amorfa.<\/p>\n            <a href=\"https:\/\/xbrele.com\/es\/contact\/\" class=\"xbrele-cta-btn\">Obtenga un presupuesto de f\u00e1brica<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Distribution Transformer Manufacturer &#038; OEM Solutions Distribution Transformer manufacturing is the backbone of the power grid, responsible for stepping down medium voltage (6kV-35kV) to usable low voltage levels. It involves two distinct technologies: Oil-Immersed (liquid-filled) transformers for outdoor utility use and Dry-Type (cast resin) transformers for indoor commercial safety. As a specialized Distribution Transformer Manufacturer, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1965","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","content_style_source":"custom","vertical_spacing_source":"custom","content_area_spacing":"top","styles_descriptor":{"styles":{"desktop":"[data-prefix=\"single_page\"] [class*=\"ct-container\"] > article[class*=\"post\"] {--has-boxed:var(--false);--has-wide:var(--true);}","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/pages\/1965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/comments?post=1965"}],"version-history":[{"count":2,"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/pages\/1965\/revisions"}],"predecessor-version":[{"id":2002,"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/pages\/1965\/revisions\/2002"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/es\/wp-json\/wp\/v2\/media?parent=1965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}