{"id":1333,"date":"2025-11-26T10:56:30","date_gmt":"2025-11-26T10:56:30","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1333"},"modified":"2026-06-04T07:29:26","modified_gmt":"2026-06-04T07:29:26","slug":"dry-type-transformer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/","title":{"rendered":"\u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e: 11kV-35kV \u0915\u093e\u0938\u094d\u091f \u0930\u0947\u091c\u093f\u0928 \u0907\u0915\u093e\u0907\u092f\u093e\u0901"},"content":{"rendered":"\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-8bea8b6\" data-block-id=\"8bea8b6\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-8bea8b6-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-86bc85f\" data-v=\"4\" data-block-id=\"86bc85f\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-86bc85f-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-86bc85f-inner-blocks\">\n<section id=\"sec1-dry-hero\" style=\"position:relative;overflow:hidden;background:radial-gradient(circle at top left,#0f172a 0,#020617 55%,#020617 100%);color:#e5e7eb;padding:200px 0 128px;\">\n  <style>\n    \/* \u4fdd\u6301\u5168\u7ad9\u7edf\u4e00\u7684 Hero \u6837\u5f0f\uff08\u672c\u6bb5\u4ec5\u6539\u4e3a\u5e72\u5f0f\u53d8\u538b\u5668\u4e13\u7528 ID\uff09 *\/\n    #sec1-dry-hero{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;}\n    #sec1-dry-hero .ckg-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec1-dry-hero .ckg-grid{display:grid;grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);gap:48px;align-items:center;}\n    #sec1-dry-hero .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38bdf8;margin-bottom:10px;}\n    #sec1-dry-hero h1{font-size:40px;line-height:1.1;letter-spacing:-.03em;margin:0 0 14px;color:#f9fafb;}\n    #sec1-dry-hero p.sub{max-width:660px;font-size:16px;line-height:1.75;margin:0 0 20px;color:#cbd5f5;text-wrap:balance;}\n    #sec1-dry-hero .badges{display:flex;flex-wrap:wrap;gap:8px;margin:22px 0 32px;}\n    #sec1-dry-hero .badge{padding:6px 12px;border-radius:999px;font-size:11px;letter-spacing:.12em;text-transform:uppercase;border:1px solid rgba(148,163,184,.55);background:rgba(15,23,42,.45);backdrop-filter:blur(14px);color:#e5e7eb;}\n    #sec1-dry-hero .hero-card{position:relative;border-radius:20px;padding:22px 22px 18px;background:radial-gradient(circle at top left,rgba(56,189,248,.20) 0,rgba(15,23,42,.95) 36%,rgba(15,23,42,1) 100%);border:1px solid rgba(148,163,184,.4);box-shadow:0 18px 45px rgba(15,23,42,.9);color:#e5e7eb;}\n    #sec1-dry-hero .hero-card h3{font-size:15px;text-transform:uppercase;letter-spacing:.16em;color:#bae6fd;margin:0 0 10px;}\n    #sec1-dry-hero .hero-card p{font-size:13px;line-height:1.7;color:#cbd5f5;margin:0 0 16px;}\n    #sec1-dry-hero .spec-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px 20px;font-size:12px;}\n    .spec-label{text-transform:uppercase;letter-spacing:.12em;color:#9ca3af;margin-bottom:2px;font-size:11px;}\n    .spec-value{font-weight:500;color:#e5e7eb;}\n    @media(max-width:1000px){#sec1-dry-hero .ckg-grid{grid-template-columns:1fr;}}\n    @media(max-width:690px){#sec1-dry-hero h1{font-size:30px;}#sec1-dry-hero .ckg-shell{padding:0 18px;}}\n  <\/style>\n\n  <div class=\"ckg-shell\">\n    <div class=\"ckg-grid\">\n\n      <!-- \u5de6\u4fa7\u6807\u9898\u533a -->\n      <div>\n        <div class=\"kicker\">Power Distribution Transformers<\/div>\n\n        <h1>Dry Type Distribution Transformers (SCB \/ SC(B) \/ SGB Series)<\/h1>\n\n        <p class=\"sub\">\n          XBRELE supplies a full range of <strong>dry type transformers<\/strong> based on cast resin and epoxy resin\n          technology, designed for indoor substations, commercial buildings and projects with strict fire-safety\n          requirements. The SCB, SC(B) and SGB series cover <strong>6\u201335&nbsp;kV classes<\/strong> with low loss,\n          reliable insulation performance and easy maintenance.\n        <\/p>\n\n        <div class=\"badges\">\n          <span class=\"badge\">SCB \/ SC(B) \/ SGB Series<\/span>\n          <span class=\"badge\">Cast &amp; Epoxy Resin<\/span>\n          <span class=\"badge\">6\u201335 kV Class<\/span>\n          <span class=\"badge\">30\u20132500 kVA<\/span>\n        <\/div>\n      <\/div>\n\n      <!-- \u53f3\u4fa7\u5361\u7247 -->\n      <aside class=\"hero-card\">\n        <h3>Series Overview<\/h3>\n        <p>\n          Environmentally friendly dry type transformers for indoor power distribution, featuring low-noise operation,\n          high fire resistance and insulation systems up to Class C. Suitable for high-rise buildings, hospitals, malls,\n          tunnels and metro projects.\n        <\/p>\n\n        <div class=\"spec-grid\">\n          <div>\n            <div class=\"spec-label\">Primary Voltage<\/div>\n            <div class=\"spec-value\">6 \/ 10 \/ 11 \/ 20 \/ 22 \/ 24 \/ 35 kV<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Secondary Voltage<\/div>\n            <div class=\"spec-value\">0.4 kV LV (others on request)<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Capacity Range<\/div>\n            <div class=\"spec-value\">30 \u2013 2500 kVA<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Insulation System<\/div>\n            <div class=\"spec-value\">Class B \/ F \/ H \/ C, up to 220&nbsp;\u00b0C<\/div>\n          <\/div>\n        <\/div>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-8cb3d39\" data-block-id=\"8cb3d39\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-8cb3d39-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-aa34972\" data-v=\"4\" data-block-id=\"aa34972\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-aa34972-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-aa34972-inner-blocks\">\n<section id=\"sec2-dry-overview\" style=\"background:#ffffff;padding:90px 0 105px;color:#0f172a;\">\n  <style>\n    \/* \u6837\u5f0f\u4fdd\u6301\u4e0d\u53d8\uff0c\u4ec5\u66ff\u6362\u4e3a\u5e72\u5f0f\u53d8\u538b\u5668\u4e13\u7528 ID *\/\n    #sec2-dry-overview{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;}\n    #sec2-dry-overview .ckg-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec2-dry-overview .overview-grid{display:grid;grid-template-columns:minmax(0,1.4fr) minmax(0,1fr);gap:52px;align-items:center;}\n    #sec2-dry-overview .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38bdf8;margin-bottom:10px;}\n    #sec2-dry-overview h2{font-size:28px;margin:0 0 14px;color:#0f172a;}\n    #sec2-dry-overview p{font-size:16px;line-height:1.85;margin:0 0 16px;color:#4b5563;}\n    #sec2-dry-overview .apps-box{background:#f9fafb;padding:22px 24px 20px;border-radius:18px;border:1px solid #e5e7eb;}\n    #sec2-dry-overview .apps-box h3{font-size:15px;margin:0 0 12px;text-transform:uppercase;letter-spacing:.14em;color:#6b7280;}\n    #sec2-dry-overview ul{list-style:none;padding:0;margin:0;display:grid;gap:10px;font-size:14px;color:#374151;}\n    #sec2-dry-overview ul li{position:relative;padding-left:16px;line-height:1.7;}\n    #sec2-dry-overview ul li::before{content:\"\";position:absolute;left:0;top:8px;width:6px;height:6px;border-radius:999px;background:#38bdf8;}\n    @media(max-width:1000px){#sec2-dry-overview .overview-grid{grid-template-columns:1fr;}}\n  <\/style>\n\n  <div class=\"ckg-shell\">\n    <div class=\"overview-grid\">\n      <div>\n        <div class=\"kicker\">Dry Type Transformer Overview<\/div>\n        <h2>Fire-Safe Dry Type Transformers for Indoor Power Distribution<\/h2>\n\n        <p>\n          <strong>Dry type transformers<\/strong> use cast resin or epoxy resin insulation instead of oil, making them\n          ideal for indoor substations and buildings with strict fire-safety requirements. XBRELE dry type\n          distribution transformers are designed for 6\u201335&nbsp;kV networks, with low loss, low noise and easy\n          maintenance for long-term operation.\n        <\/p>\n\n        <p>\n          Based on SCB, SC(B) and SGB series designs, these <strong>cast resin transformers<\/strong> and\n          <strong>epoxy resin transformers<\/strong> provide reliable performance in high-rise buildings, hospitals,\n          metro stations, commercial complexes and other densely populated areas where oil-filled units are\n          not preferred.\n        <\/p>\n        \n        <p>\n          XBRELE products are developed with reference to international standards such as \n          <a href=\"https:\/\/webstore.iec.ch\/publication\/2618\" style=\"color:#2563EB;text-decoration:none;\" target=\"_blank\" rel=\"noopener\">\n            IEC&nbsp;60076-11 dry-type power transformers\n          <\/a>, ensuring consistent insulation levels and temperature-rise performance.\n        <\/p>\n\n        <p style=\"margin-top:14px;font-size:14px;color:#4b5563;\">\n          For a complete view of our power distribution transformer portfolio, including oil-immersed and\n          <strong>11&nbsp;kV dry type transformer<\/strong> options, visit the \n          <a href=\"https:\/\/xbrele.com\/power-distribution-transformers\" style=\"color:#2563EB;text-decoration:none;\">\n            Power Distribution Transformers pillar page\n          <\/a>.\n        <\/p>\n      <\/div>\n\n      <aside class=\"apps-box\">\n        <h3>Typical Applications<\/h3>\n        <ul>\n          <li><strong>Indoor Substations:<\/strong> Dry type transformers for 6\u201335&nbsp;kV distribution inside buildings.<\/li>\n          <li><strong>High-Rise &amp; Commercial Buildings:<\/strong> Fire resistant transformer solutions for malls, offices and complexes.<\/li>\n          <li><strong>Hospitals &amp; Public Facilities:<\/strong> Low-noise indoor transformer operation with reduced maintenance.<\/li>\n          <li><strong>Tunnels, Metro &amp; Infrastructure:<\/strong> Cast resin transformers for enclosed spaces with strict safety regulations.<\/li>\n        <\/ul>\n      <\/aside>\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-5af40a2\" data-block-id=\"5af40a2\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-5af40a2-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-0455c18\" data-v=\"4\" data-block-id=\"0455c18\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-0455c18-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-0455c18-inner-blocks\">\n<section id=\"sec3-dry-tech\" style=\"padding:90px 0;background:#F9FAFB;\">\n  <style>\n    \/* --- \u57fa\u7840\u5bb9\u5668\u4e0e\u6392\u7248 --- *\/\n    #sec3-dry-tech{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n    #sec3-dry-tech .tech-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec3-dry-tech .sec-header{max-width:820px;margin:0 auto 32px;text-align:center;}\n    #sec3-dry-tech .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec3-dry-tech h2{font-size:28px;margin:0 0 10px;color:#0F172A;}\n    #sec3-dry-tech .sec-header p{margin:0;font-size:15px;color:#4B5563;line-height:1.8;}\n\n    \/* --- \u5916\u5c42 TAB \u5bfc\u822a\u6837\u5f0f --- *\/\n    #sec3-dry-tech .tab-row{display:flex;flex-wrap:wrap;justify-content:center;gap:10px;margin:34px 0 32px;}\n    #sec3-dry-tech .tab-btn{padding:10px 22px;font-size:14px;font-weight:600;background:#E5E7EB;border-radius:999px;cursor:pointer;border:1px solid #D1D5DB;transition:all .25s ease;color:#0F172A;white-space:nowrap;}\n    #sec3-dry-tech .tab-btn:hover{background:#DDE3E9;}\n    #sec3-dry-tech .tab-btn.active{background:#0F172A;color:#F9FAFB;border-color:#0F172A;box-shadow:0 10px 24px rgba(15,23,42,.18);}\n\n    \/* --- \u5185\u5bb9\u533a\u57df\u52a8\u753b --- *\/\n    #sec3-dry-tech .tab-content{display:none;animation:fadeIn .25s ease;}\n    #sec3-dry-tech .tab-content.active{display:block;}\n    @keyframes fadeIn{from{opacity:0;transform:translateY(6px);}to{opacity:1;transform:translateY(0);}}\n\n    \/* --- \u5361\u7247\u4e0e\u5e03\u5c40 --- *\/\n    #sec3-dry-tech .panel-card{border-radius:20px;border:1px solid #E5E7EB;background:#FFFFFF;padding:24px 22px 30px;box-shadow:0 14px 32px rgba(15,23,42,.05);}\n    #sec3-dry-tech .panel-grid{display:grid;grid-template-columns:minmax(0,1.15fr) minmax(0,1.1fr);gap:22px;margin-bottom:24px;align-items:flex-start;}\n\n    \/* --- \u56fe\u7247\u4e0e\u8bf4\u660e --- *\/\n    #sec3-dry-tech .main-fig-large{margin:0;border-radius:14px;border:1px solid #E5E7EB;background:#F9FAFB;padding:10px;}\n    #sec3-dry-tech .main-fig-large img{display:block;width:100%;max-height:320px;object-fit:contain;}\n    #sec3-dry-tech .main-fig-large figcaption{margin-top:8px;font-size:12px;color:#6B7280;line-height:1.6;}\n\n    #sec3-dry-tech .panel-right h3{font-size:16px;margin:0 0 10px;color:#0F172A;}\n    #sec3-dry-tech .panel-right p{font-size:14px;line-height:1.8;margin:0 0 10px;color:#4B5563;}\n    #sec3-dry-tech .badge-row{display:flex;flex-wrap:wrap;gap:8px;margin:8px 0 14px;}\n    #sec3-dry-tech .badge{padding:4px 10px;border-radius:999px;font-size:11px;letter-spacing:.12em;text-transform:uppercase;border:1px solid #D1D5DB;background:#F9FAFB;color:#4B5563;}\n\n    \/* --- \u8868\u683c\u901a\u7528\u6837\u5f0f --- *\/\n    #sec3-dry-tech .block-title{font-size:14px;font-weight:600;margin:4px 0 6px;color:#111827;}\n    #sec3-dry-tech .table-wrap{width:100%;overflow-x:auto;border-radius:14px;border:1px solid #E5E7EB;background:#F9FAFB;margin-bottom:18px;box-shadow:inset -10px 0 10px -10px rgba(0,0,0,0.05);}\n    #sec3-dry-tech table{width:100%;border-collapse:separate;border-spacing:0;font-size:13px;min-width:600px;}\n    #sec3-dry-tech th,#sec3-dry-tech td{padding:10px 12px;border-bottom:1px solid #E5E7EB;text-align:left;color:#111827;white-space:nowrap;}\n    #sec3-dry-tech th:first-child,#sec3-dry-tech td:first-child{position:sticky;left:0;z-index:2;border-right:2px solid #E5E7EB;}\n    #sec3-dry-tech tbody tr:nth-child(odd) td:first-child{background:#FFFFFF;}\n    #sec3-dry-tech tbody tr:nth-child(even) td:first-child{background:#F9FAFB;}\n    #sec3-dry-tech thead th:first-child{background:#E5F0FF;z-index:3;}\n    #sec3-dry-tech th{font-size:12px;text-transform:uppercase;letter-spacing:.08em;color:#374151;font-weight:600;}\n    #sec3-dry-tech tbody tr:nth-child(odd){background:#FFFFFF;}\n    #sec3-dry-tech tbody tr:nth-child(even){background:#F9FAFB;}\n    #sec3-dry-tech thead{background:#E5F0FF;}\n\n    \/* --- \u6309\u94ae\u4e0e\u54cd\u5e94\u5f0f --- *\/\n    #sec3-dry-tech .cta-right-col{display:flex;justify-content:center;margin-top:26px;}\n    #sec3-dry-tech .cta-btn{display:inline-block;padding:12px 30px;background:#0F172A;color:#F9FAFB;font-size:15px;font-weight:600;border-radius:8px;text-decoration:none;letter-spacing:.03em;transition:all .25s ease;box-shadow:0 10px 24px rgba(15,23,42,.18);white-space:nowrap;}\n    #sec3-dry-tech .cta-btn:hover{background:#1E293B;box-shadow:0 14px 32px rgba(15,23,42,.25);transform:translateY(-1px);}\n\n    @media(max-width:1000px){#sec3-dry-tech .panel-grid{grid-template-columns:1fr;}}\n    @media(max-width:690px){#sec3-dry-tech .tech-shell{padding:0 18px;}#sec3-dry-tech h2{font-size:24px;}}\n    \n    \/* --- SCB10 \u5185\u5c42\u5b50 TAB \u4e13\u7528\u6837\u5f0f --- *\/\n    #sec3-dry-tech .dry-scb10-sub-tabs{display:flex;flex-wrap:wrap;gap:8px;margin:32px 0 20px;}\n    #sec3-dry-tech .dry-scb10-sub-tabs .dry-scb10-sub-tab-btn{border:1px solid #CBD5E1;padding:8px 16px;border-radius:999px;font-size:14px;line-height:1.4;cursor:pointer;background:#FFFFFF;color:#0F172A;transition:all .2s ease;}\n    #sec3-dry-tech .dry-scb10-sub-tabs .dry-scb10-sub-tab-btn:hover{border-color:#38BDF8;}\n    #sec3-dry-tech .dry-scb10-sub-tabs .dry-scb10-sub-tab-btn.active{background:#0F172A;border-color:#0F172A;color:#FFFFFF;}\n    \n    \/* \u5173\u952e\uff1a\u63a7\u5236\u5b50 TAB \u9762\u677f\u7684\u663e\u793a\u4e0e\u9690\u85cf *\/\n    #sec3-dry-tech .dry-scb10-sub-panel{display:none; animation:fadeIn .25s ease;}\n    #sec3-dry-tech .dry-scb10-sub-panel.active{display:block;}\n  <\/style>\n\n  <div class=\"tech-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Technical Specifications<\/div>\n      <h2>Dry Type Transformer Data by Series<\/h2>\n      <p>\n        Switch between SCB10 \/ SCB11, SCB13, SCB11-35kV and SG(B)10 eco-friendly dry type transformers to review\n        rated capacities, voltage combinations and key loss parameters for indoor, fire resistant applications.\n      <\/p>\n    <\/div>\n\n    <div class=\"tab-row\">\n      <div class=\"tab-btn active\" data-tab=\"scb10-series\">SCB10 \/ SCB11 (10\/20kV)<\/div>\n      <div class=\"tab-btn\" data-tab=\"scb13-series\">SCB13 Low-loss Dry Type (6\/10kV)<\/div>\n      <div class=\"tab-btn\" data-tab=\"dry-35kv-series\">SCB11-35kV Dry Type Power<\/div>\n      <div class=\"tab-btn\" data-tab=\"sgb10-series\">SG(B)10 Eco-friendly Dry Type<\/div>\n    <\/div>\n\n    <div id=\"scb10-series\" class=\"tab-content active\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <div>\n            <figure class=\"main-fig-large\">\n              <img decoding=\"async\" id=\"dry-scb10-main-img\"\n                   src=\"\/wp-content\/uploads\/2025\/11\/xbrele-scb10-scb11-dry-type-transformer-main.webp\"\n                   alt=\"XBRELE SCB10 epoxy cast dry type transformer for 6-11kV and 20kV indoor distribution\">\n              <figcaption id=\"dry-scb10-main-cap\">\n                SCB10 \/ SCB11 epoxy cast dry-type distribution transformer for 6&ndash;11kV and 20kV systems,\n                designed for indoor substations, commercial buildings and fire-safety critical projects.\n              <\/figcaption>\n            <\/figure>\n          <\/div>\n\n          <div class=\"panel-right\">\n            <h3>SCB10 \/ SCB11 Epoxy Cast Dry-Type Distribution Transformers<\/h3>\n            <p>\n              SCB10 and SCB11 dry-type transformers adopt vacuum cast epoxy resin technology with F or H class\n              insulation, low partial discharge and excellent fire resistance. They are widely used in high-rise\n              buildings, commercial complexes, hospitals, schools, subways and indoor substations where strict\n              fire-safety requirements apply.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">Dry type<\/span>\n              <span class=\"badge\">SCB10 \/ SCB11<\/span>\n              <span class=\"badge\">6&ndash;11kV &amp; 20kV<\/span>\n              <span class=\"badge\">Indoor distribution<\/span>\n            <\/div>\n          <\/div>\n        <\/div>\n\n        <div class=\"dry-scb10-sub-tabs\">\n          <button class=\"dry-scb10-sub-tab-btn active\" data-sub-target=\"dry-scb10-6-11kv\">\n            SCB10 6&ndash;11kV Technical Data\n          <\/button>\n          <button class=\"dry-scb10-sub-tab-btn\" data-sub-target=\"dry-scb10-20kv\">\n            SCB10 20kV Technical Data\n          <\/button>\n        <\/div>\n\n        <div id=\"dry-scb10-6-11kv\" class=\"dry-scb10-sub-panel active\">\n          <p class=\"block-title\">\n            Main Technical Parameters \u2014 SCB10 6\/10kV 30\u20132500kVA Dry-Type Voltage Regulation Distribution Transformer\n          <\/p>\n          <div class=\"table-wrap\">\n            <table>\n              <thead>\n                <tr>\n                  <th>Rated capacity (kVA)<\/th>\n                  <th>No-load loss (kW)<\/th>\n                  <th>Load loss 130\u00b0C (kW)<\/th>\n                  <th>Load loss 155\u00b0C (kW)<\/th>\n                  <th>Load loss 180\u00b0C (kW)<\/th>\n                  <th>No-load current (%)<\/th>\n                  <th>Short-circuit impedance (%)<\/th>\n                <\/tr>\n              <\/thead>\n              <tbody>\n                <tr><td>30<\/td><td>0.19<\/td><td>0.67<\/td><td>0.71<\/td><td>0.76<\/td><td>2<\/td><td>4.0<\/td><\/tr>\n                <tr><td>50<\/td><td>0.27<\/td><td>0.94<\/td><td>1<\/td><td>1.07<\/td><td>2<\/td><td>4.0<\/td><\/tr>\n                <tr><td>80<\/td><td>0.37<\/td><td>1.29<\/td><td>1.38<\/td><td>1.48<\/td><td>1.5<\/td><td>4.0<\/td><\/tr>\n                <tr><td>100<\/td><td>0.40<\/td><td>1.48<\/td><td>1.57<\/td><td>1.69<\/td><td>1.5<\/td><td>4.0<\/td><\/tr>\n                <tr><td>125<\/td><td>0.47<\/td><td>1.74<\/td><td>2.85<\/td><td>1.98<\/td><td>1.3<\/td><td>4.0<\/td><\/tr>\n                <tr><td>160<\/td><td>0.54<\/td><td>2.00<\/td><td>2.13<\/td><td>2.28<\/td><td>1.3<\/td><td>4.0<\/td><\/tr>\n                <tr><td>200<\/td><td>0.52<\/td><td>2.37<\/td><td>2.53<\/td><td>2.71<\/td><td>1.1<\/td><td>4.0<\/td><\/tr>\n                <tr><td>250<\/td><td>0.72<\/td><td>2.59<\/td><td>2.26<\/td><td>2.96<\/td><td>1.1<\/td><td>4.0<\/td><\/tr>\n                <tr><td>315<\/td><td>0.88<\/td><td>3.27<\/td><td>3.47<\/td><td>3.73<\/td><td>1.0<\/td><td>4.0<\/td><\/tr>\n                <tr><td>400<\/td><td>0.98<\/td><td>3.75<\/td><td>3.99<\/td><td>4.28<\/td><td>1.0<\/td><td>4.0<\/td><\/tr>\n                <tr><td>500<\/td><td>1.16<\/td><td>4.59<\/td><td>4.88<\/td><td>5.23<\/td><td>1.0<\/td><td>4.0<\/td><\/tr>\n                <tr><td>630<\/td><td>1.34<\/td><td>6.53<\/td><td>5.88<\/td><td>5.29<\/td><td>0.85<\/td><td>6.0<\/td><\/tr>\n                <tr><td>630 (20\/24kV)<\/td><td>1.30<\/td><td>5.61<\/td><td>5.96<\/td><td>6.40<\/td><td>0.85<\/td><td>6.0<\/td><\/tr>\n                <tr><td>800<\/td><td>1.52<\/td><td>6.55<\/td><td>6.96<\/td><td>7.46<\/td><td>0.85<\/td><td>6.0<\/td><\/tr>\n                <tr><td>1000<\/td><td>1.77<\/td><td>7.65<\/td><td>8.13<\/td><td>8.76<\/td><td>0.85<\/td><td>6.0<\/td><\/tr>\n                <tr><td>1250<\/td><td>2.09<\/td><td>9.10<\/td><td>9.69<\/td><td>10.3<\/td><td>0.85<\/td><td>6.0<\/td><\/tr>\n                <tr><td>1600<\/td><td>2.45<\/td><td>11.0<\/td><td>11.7<\/td><td>12.5<\/td><td>0.85<\/td><td>6.0<\/td><\/tr>\n                <tr><td>2000<\/td><td>3.05<\/td><td>13.6<\/td><td>14.4<\/td><td>15.5<\/td><td>0.70<\/td><td>6.0<\/td><\/tr>\n                <tr><td>2500<\/td><td>3.60<\/td><td>16.1<\/td><td>17.1<\/td><td>18.4<\/td><td>0.70<\/td><td>6.0<\/td><\/tr>\n                <tr><td>1600 (20\/24kV)<\/td><td>2.45<\/td><td>12.2<\/td><td>12.9<\/td><td>13.9<\/td><td>0.85<\/td><td>8.0<\/td><\/tr>\n                <tr><td>2000 (20\/24kV)<\/td><td>3.05<\/td><td>15.0<\/td><td>15.9<\/td><td>17.1<\/td><td>0.70<\/td><td>8.0<\/td><\/tr>\n                <tr><td>2500 (20\/24kV)<\/td><td>3.60<\/td><td>17.7<\/td><td>18.8<\/td><td>20.2<\/td><td>0.70<\/td><td>8.0<\/td><\/tr>\n              <\/tbody>\n            <\/table>\n          <\/div>\n          <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n            Note: 6kV \/ 10kV high-voltage windings with tap ranges \u00b12.5% \/ \u00b15% (and \u00b12\u00d72.5% for part of the ratings). \n            20\/22\/24kV versions are marked in brackets. Data come directly from the SCB10 manufacturer catalogue.\n          <\/p>\n        <\/div>\n\n        <div id=\"dry-scb10-20kv\" class=\"dry-scb10-sub-panel\">\n          <p class=\"block-title\">\n            Main Technical Parameters \u2014 SCB10 20kV 30\u20132500kVA Dry-Type Distribution Transformer\n          <\/p>\n          <div class=\"table-wrap\">\n            <table>\n              <thead>\n                <tr>\n                  <th>Rated capacity (kVA)<\/th>\n                  <th>No-load loss (W)<\/th>\n                  <th>Load loss (W)<\/th>\n                  <th>No-load current (%)<\/th>\n                  <th>Short-circuit impedance (%)<\/th>\n                <\/tr>\n              <\/thead>\n              <tbody>\n                <tr><td>30<\/td><td>33<\/td><td>630 \/ 600<\/td><td>1.50<\/td><td>4.0<\/td><\/tr>\n                <tr><td>50<\/td><td>43<\/td><td>910 \/ 870<\/td><td>1.20<\/td><td>4.0<\/td><\/tr>\n                <tr><td>63<\/td><td>50<\/td><td>1090 \/ 1040<\/td><td>1.10<\/td><td>4.0<\/td><\/tr>\n                <tr><td>80<\/td><td>80<\/td><td>1310 \/ 1250<\/td><td>1.00<\/td><td>4.0<\/td><\/tr>\n                <tr><td>100<\/td><td>75<\/td><td>1580 \/ 1500<\/td><td>0.90<\/td><td>4.0<\/td><\/tr>\n                <tr><td>125<\/td><td>85<\/td><td>1890 \/ 1800<\/td><td>0.80<\/td><td>4.0<\/td><\/tr>\n                <tr><td>160<\/td><td>100<\/td><td>2310 \/ 2200<\/td><td>0.60<\/td><td>4.0<\/td><\/tr>\n                <tr><td>200<\/td><td>120<\/td><td>2730 \/ 2600<\/td><td>0.60<\/td><td>4.0<\/td><\/tr>\n                <tr><td>250<\/td><td>140<\/td><td>3200 \/ 3050<\/td><td>0.60<\/td><td>4.0<\/td><\/tr>\n                <tr><td>315<\/td><td>170<\/td><td>3830 \/ 3650<\/td><td>0.50<\/td><td>4.0<\/td><\/tr>\n                <tr><td>400<\/td><td>200<\/td><td>4520 \/ 4300<\/td><td>0.50<\/td><td>4.0<\/td><\/tr>\n                <tr><td>500<\/td><td>240<\/td><td>5410 \/ 5150<\/td><td>0.50<\/td><td>4.0<\/td><\/tr>\n                <tr><td>630<\/td><td>320<\/td><td>6200<\/td><td>0.30<\/td><td>4.5<\/td><\/tr>\n                <tr><td>800<\/td><td>380<\/td><td>7500<\/td><td>0.30<\/td><td>4.5<\/td><\/tr>\n                <tr><td>1000<\/td><td>450<\/td><td>10300<\/td><td>0.30<\/td><td>4.5<\/td><\/tr>\n                <tr><td>1250<\/td><td>530<\/td><td>12000<\/td><td>0.20<\/td><td>4.5<\/td><\/tr>\n                <tr><td>1600<\/td><td>630<\/td><td>14500<\/td><td>0.20<\/td><td>5.0<\/td><\/tr>\n                <tr><td>2000<\/td><td>750<\/td><td>18300<\/td><td>0.20<\/td><td>5.0<\/td><\/tr>\n                <tr><td>2500<\/td><td>900<\/td><td>21200<\/td><td>0.20<\/td><td>5.0<\/td><\/tr>\n              <\/tbody>\n            <\/table>\n          <\/div>\n          <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n            Note: 20kV SCB10 series uses high-voltage windings of 6 \/ 6.3 \/ 10 \/ 10.5 \/ 11kV on the low-voltage side, \n            with tap ranges \u00b12\u00d72.5% \/ \u00b15%. All data originate from the SCB10 20kV manufacturer catalogue.\n          <\/p>\n        <\/div>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">\n            Request SCB10 \/ SCB11 Quote\n          <\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"scb13-series\" class=\"tab-content\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <figure class=\"main-fig-large\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/xbrele-scb13-dry-type-transformer-main.webp\"\n                 alt=\"SC(B)13-10kV Epoxy cast dry-type transformer with foil coil structure\">\n            <figcaption>\n              SC(B)13-10kV Epoxy cast dry-type transformer. Suitable for high fire protection requirements like subways, hospitals, and high-rise buildings.\n            <\/figcaption>\n          <\/figure>\n          \n          <div class=\"panel-right\">\n            <h3>SC(B)13-10kV Series Resin Insulation Dry-Type Transformer<\/h3>\n            <div class=\"badge-row\">\n              <span class=\"badge\">SC(B)13 Series<\/span>\n              <span class=\"badge\">Foil Coil Structure<\/span>\n              <span class=\"badge\">Moisture Proof<\/span>\n              <span class=\"badge\">Low Noise<\/span>\n            <\/div>\n            <p>\n              <strong>Scope of Application:<\/strong> Especially suitable for places with high fire protection requirements, such as mines, oil fields, subways, power plants, schools, hospitals, commercial centers, and high-rise buildings.\n            <\/p>\n            <p style=\"font-size:13px; color:#4B5563; margin-top:8px;\">\n              <strong>Structural Features:<\/strong>\n              <ul style=\"padding-left:18px; margin:5px 0; font-size:13px; color:#4B5563; line-height:1.6;\">\n                <li><strong>Foil Coil:<\/strong> Low voltage winding uses whole copper foil winding to solve low voltage\/high current problems.<\/li>\n                <li><strong>Core Iron:<\/strong> 45\u00b0 fully oblique step joint with high magnetic permeability silicon steel sheet.<\/li>\n                <li><strong>Temp Control:<\/strong> BWDK series signal thermometer buried in the LV coil.<\/li>\n                <li><strong>Moisture Proof:<\/strong> Can operate normally under 100% humidity without pre-drying.<\/li>\n              <\/ul>\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <div class=\"block-title\">Main Technical Parameters \u2014 SCB13 6kV\/10kV Class 13 Dry-Type Transformer<\/div>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th>Rated Capacity (kVA)<\/th>\n                <th>No-load Loss (kW)<\/th>\n                <th>Load Loss 130\u00b0C (kW)<\/th>\n                <th>Load Loss 155\u00b0C (kW)<\/th>\n                <th>Load Loss 180\u00b0C (kW)<\/th>\n                <th>Imp. (%)<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <tr><td>30<\/td><td>0.135<\/td><td>0.605<\/td><td>0.640<\/td><td>0.685<\/td><td>4.0<\/td><\/tr>\n              <tr><td>50<\/td><td>0.195<\/td><td>0.845<\/td><td>0.900<\/td><td>0.965<\/td><td>4.0<\/td><\/tr>\n              <tr><td>80<\/td><td>0.265<\/td><td>1.16<\/td><td>1.40<\/td><td>1.33<\/td><td>4.0<\/td><\/tr>\n              <tr><td>100<\/td><td>0.290<\/td><td>1.33<\/td><td>1.41<\/td><td>1.52<\/td><td>4.0<\/td><\/tr>\n              <tr><td>125<\/td><td>0.340<\/td><td>1.56<\/td><td>1.66<\/td><td>1.78<\/td><td>4.0<\/td><\/tr>\n              <tr><td>160<\/td><td>0.385<\/td><td>1.80<\/td><td>1.91<\/td><td>2.02<\/td><td>4.0<\/td><\/tr>\n              <tr><td>200<\/td><td>0.445<\/td><td>2.13<\/td><td>2.27<\/td><td>2.44<\/td><td>4.0<\/td><\/tr>\n              <tr><td>250<\/td><td>0.515<\/td><td>2.33<\/td><td>2.48<\/td><td>2.66<\/td><td>4.0<\/td><\/tr>\n              <tr><td>315<\/td><td>0.635<\/td><td>2.94<\/td><td>3.12<\/td><td>3.35<\/td><td>4.0<\/td><\/tr>\n              <tr><td>400<\/td><td>0.705<\/td><td>3.37<\/td><td>3.59<\/td><td>3.85<\/td><td>4.0<\/td><\/tr>\n              <tr><td>500<\/td><td>0.835<\/td><td>4.13<\/td><td>4.39<\/td><td>4.70<\/td><td>4.0<\/td><\/tr>\n              <tr><td>630 (Type A)<\/td><td>0.965<\/td><td>4.97<\/td><td>5.29<\/td><td>5.66<\/td><td>4.0<\/td><\/tr>\n              <tr><td>630 (Type B)<\/td><td>0.935<\/td><td>5.05<\/td><td>5.36<\/td><td>5.76<\/td><td>6.0<\/td><\/tr>\n              <tr><td>800<\/td><td>1.09<\/td><td>5.89<\/td><td>6.26<\/td><td>6.71<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1000<\/td><td>1.27<\/td><td>6.88<\/td><td>7.31<\/td><td>7.88<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1200<\/td><td>1.50<\/td><td>8.19<\/td><td>8.72<\/td><td>9.33<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1600<\/td><td>1.76<\/td><td>9.94<\/td><td>10.5<\/td><td>11.3<\/td><td>6.0<\/td><\/tr>\n              <tr><td>2000<\/td><td>2.19<\/td><td>12.2<\/td><td>13.0<\/td><td>14.0<\/td><td>6.0<\/td><\/tr>\n              <tr><td>2500<\/td><td>2.59<\/td><td>14.5<\/td><td>15.4<\/td><td>16.6<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1600 (High Imp)<\/td><td>1.76<\/td><td>11.0<\/td><td>11.6<\/td><td>12.5<\/td><td>8.0<\/td><\/tr>\n              <tr><td>2000 (High Imp)<\/td><td>2.19<\/td><td>13.5<\/td><td>14.3<\/td><td>15.4<\/td><td>8.0<\/td><\/tr>\n              <tr><td>2500 (High Imp)<\/td><td>2.59<\/td><td>15.9<\/td><td>17.0<\/td><td>18.2<\/td><td>8.0<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n        <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n           Note: Data derived from SCB13 6kV\/10kV Class 13 dry-type non-excitation voltage regulation distribution transformer technical parameters. \n        <\/p>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">\n            Request SCB13 Quote\n          <\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"dry-35kv-series\" class=\"tab-content\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <figure class=\"main-fig-large\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/xbrele-scb11-35kv-dry-type-transformer-main.webp\"\n                 alt=\"SCB11-35kV Cast Resin Dry-type Transformer\">\n            <figcaption>\n              SCB11-35kV Series Cast Resin Dry-type Transformer. High voltage level 35kV, designed for heavy-duty industrial and substation applications.\n            <\/figcaption>\n          <\/figure>\n          \n          <div class=\"panel-right\">\n            <h3>SCB11-35kV Dry Type Power Transformers<\/h3>\n            <div class=\"badge-row\">\n              <span class=\"badge\">35kV \/ 0.4kV<\/span>\n              <span class=\"badge\">Epoxy Casting<\/span>\n              <span class=\"badge\">Low Voltage Foil Coil<\/span>\n            <\/div>\n            <p>\n              <strong>Product Overview:<\/strong> The SCB11-35kV series utilizes three-phase solid molding (epoxy vacuum casting) and low-voltage foil coil technology. It offers high mechanical strength, short-circuit resistance, and is maintenance-free.\n            <\/p>\n            <p style=\"font-size:13px; color:#4B5563; margin-top:8px;\">\n              <strong>Key Specifications:<\/strong>\n              <ul style=\"padding-left:18px; margin:5px 0; font-size:13px; color:#4B5563; line-height:1.6;\">\n                <li><strong>Voltage:<\/strong> HV 35kV (35, 36, 37, 38.5) \/ LV 0.4kV<\/li>\n                <li><strong>Insulation Level:<\/strong> LI170AC70 \/ AC5<\/li>\n                <li><strong>Join Groups:<\/strong> Dyn11, Yyn0<\/li>\n                <li><strong>Tapping Range:<\/strong> \u00b12&#215;2.5% or \u00b15%<\/li>\n              <\/ul>\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <div class=\"block-title\">Main Technical Parameters \u2014 SCB11 35kV Series<\/div>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th>Rated Capacity (kVA)<\/th>\n                <th>No-load Loss (kW)<\/th>\n                <th>Load Loss 130\u00b0C (kW)<\/th>\n                <th>Load Loss 155\u00b0C (kW)<\/th>\n                <th>Load Loss 180\u00b0C (kW)<\/th>\n                <th>No-load Current (%)<\/th>\n                <th>Imp. (%)<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <tr><td>50<\/td><td>0.450<\/td><td>1.34<\/td><td>1.42<\/td><td>1.52<\/td><td>2.3<\/td><td>6.0<\/td><\/tr>\n              <tr><td>100<\/td><td>0.630<\/td><td>1.97<\/td><td>2.09<\/td><td>2.23<\/td><td>2.0<\/td><td>6.0<\/td><\/tr>\n              <tr><td>160<\/td><td>0.790<\/td><td>2.65<\/td><td>2.81<\/td><td>3.00<\/td><td>1.5<\/td><td>6.0<\/td><\/tr>\n              <tr><td>200<\/td><td>0.880<\/td><td>3.13<\/td><td>3.32<\/td><td>3.55<\/td><td>1.5<\/td><td>6.0<\/td><\/tr>\n              <tr><td>250<\/td><td>0.990<\/td><td>3.58<\/td><td>3.80<\/td><td>4.06<\/td><td>1.3<\/td><td>6.0<\/td><\/tr>\n              <tr><td>315<\/td><td>1.17<\/td><td>4.25<\/td><td>4.51<\/td><td>4.82<\/td><td>1.3<\/td><td>6.0<\/td><\/tr>\n              <tr><td>400<\/td><td>1.37<\/td><td>5.10<\/td><td>5.41<\/td><td>5.79<\/td><td>1.1<\/td><td>6.0<\/td><\/tr>\n              <tr><td>500<\/td><td>1.52<\/td><td>6.27<\/td><td>6.65<\/td><td>7.11<\/td><td>1.1<\/td><td>6.0<\/td><\/tr>\n              <tr><td>630<\/td><td>1.86<\/td><td>7.25<\/td><td>7.69<\/td><td>8.23<\/td><td>1.0<\/td><td>6.0<\/td><\/tr>\n              <tr><td>800<\/td><td>2.16<\/td><td>8.60<\/td><td>9.12<\/td><td>9.76<\/td><td>1.0<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1000<\/td><td>2.43<\/td><td>9.86<\/td><td>10.4<\/td><td>11.1<\/td><td>0.75<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1250<\/td><td>2.83<\/td><td>12.0<\/td><td>12.7<\/td><td>13.6<\/td><td>0.75<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1600<\/td><td>3.24<\/td><td>14.6<\/td><td>15.4<\/td><td>16.5<\/td><td>0.75<\/td><td>6.0<\/td><\/tr>\n              <tr><td>2000<\/td><td>3.82<\/td><td>17.2<\/td><td>18.2<\/td><td>19.5<\/td><td>0.75<\/td><td>6.0<\/td><\/tr>\n              <tr><td>2500<\/td><td>4.45<\/td><td>20.3<\/td><td>21.8<\/td><td>23.3<\/td><td>0.75<\/td><td>6.0<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n        <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n           Note: HV rated voltages: 35kV, 36kV, 37kV, 38.5kV. Tapping range: \u00b12\u00d72.5% or \u00b15%. <br>\n           Load losses listed correspond to different insulation system temperatures (B=100K rise\/130\u00b0C, F=120K rise\/155\u00b0C, H=145K rise\/180\u00b0C) per GB1094.11.\n        <\/p>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">\n            Request 35kV Series Quote\n          <\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"sgb10-series\" class=\"tab-content\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <figure class=\"main-fig-large\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/xbrele-sgb10-eco-dry-type-transformer-main.webp\"\n                 alt=\"SG(B)10-10kV Environmentally friendly dry-type transformers\">\n            <figcaption>\n              SG(B)10-10kV Environmentally friendly dry-type transformers. High safety, reliable operation, and environmentally friendly insulation materials.\n            <\/figcaption>\n          <\/figure>\n          \n          <div class=\"panel-right\">\n            <h3>SG(B)10 Eco-friendly Dry Type Transformers<\/h3>\n            <div class=\"badge-row\">\n              <span class=\"badge\">Class H Insulation<\/span>\n              <span class=\"badge\">Non-Toxic<\/span>\n              <span class=\"badge\">Moisture Proof<\/span>\n            <\/div>\n            <p>\n              <strong>Product Features:<\/strong> The product uses DuPont new materials with insulation heat resistance grades reaching Class H (180\u00b0C) and key parts reaching Class C (220\u00b0C). \n            <\/p>\n            <p style=\"font-size:13px; color:#4B5563; margin-top:8px;\">\n              <strong>Safety &#038; Reliability:<\/strong>\n              <ul style=\"padding-left:18px; margin:5px 0; font-size:13px; color:#4B5563; line-height:1.6;\">\n                 <li><strong>Safe:<\/strong> Non-combustible, self-extinguishing, and non-toxic. No toxic smoke at 800\u00b0C. Ideal for subways, ships, and chemical plants.<\/li>\n                 <li><strong>Reliable:<\/strong> NOMEX-based insulation system withstands thermal shock and has no partial discharge. Excellent resistance to moisture, mold, and smoke.<\/li>\n              <\/ul>\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <div class=\"block-title\">Insulation Heat Resistance &#038; Temperature Rise Limits<\/div>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th>Temperature Grade<\/th>\n                <th>Grade B<\/th>\n                <th>Grade F<\/th>\n                <th>Grade H<\/th>\n                <th>Grade C<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n               <tr>\n                 <td>Average Temperature Rise (\u00b0C)<\/td>\n                 <td>80<\/td>\n                 <td>100<\/td>\n                 <td>125<\/td>\n                 <td>150<\/td>\n               <\/tr>\n               <tr>\n                 <td>Maximum Ambient Temperature (\u00b0C)<\/td>\n                 <td>40<\/td>\n                 <td>40<\/td>\n                 <td>40<\/td>\n                 <td>40<\/td>\n               <\/tr>\n               <tr>\n                 <td>Hot Spot Temperature Tolerance (\u00b0C)<\/td>\n                 <td>10<\/td>\n                 <td>15<\/td>\n                 <td>20<\/td>\n                 <td>30<\/td>\n               <\/tr>\n               <tr>\n                 <td>Maximum Temperature (\u00b0C)<\/td>\n                 <td>130<\/td>\n                 <td>155<\/td>\n                 <td>180<\/td>\n                 <td>220<\/td>\n               <\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n        <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n           Note: Data reference for SG(B)10 type dry transformer insulation heat resistance grades.\n        <\/p>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">\n            Request SG(B)10 Quote\n          <\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n\n  <\/div>\n\n  <script>\n    (function(){\n      const root = document.getElementById('sec3-dry-tech');\n      if(!root) return;\n\n      \/\/ --- 1. \u5916\u5c42 TAB \u903b\u8f91 (\u56db\u4e2a\u4e3b\u8981\u7cfb\u5217\u5207\u6362) ---\n      const mainBtns = root.querySelectorAll('.tab-btn');\n      const mainTabs = root.querySelectorAll('.tab-content');\n\n      mainBtns.forEach(btn=>{\n        btn.addEventListener('click',()=>{\n          const target = btn.getAttribute('data-tab');\n          \/\/ \u79fb\u9664\u6240\u6709 active \u72b6\u6001\n          mainBtns.forEach(b=>b.classList.remove('active'));\n          mainTabs.forEach(t=>t.classList.remove('active'));\n          \/\/ \u6fc0\u6d3b\u5f53\u524d\u70b9\u51fb\u9879\n          btn.classList.add('active');\n          const tab = root.querySelector('#'+target);\n          if(tab) tab.classList.add('active');\n        });\n      });\n\n      \/\/ --- 2. \u5185\u5c42\u5b50 TAB \u903b\u8f91 (SCB10 \u7cfb\u5217\u5185\u7684 6-11kV vs 20kV \u5207\u6362) ---\n      const subBtns = root.querySelectorAll('.dry-scb10-sub-tab-btn');\n      const subPanels = root.querySelectorAll('.dry-scb10-sub-panel');\n\n      subBtns.forEach(btn=>{\n        btn.addEventListener('click', (e)=>{\n          \/\/ \u963b\u6b62\u4e8b\u4ef6\u5192\u6ce1 (\u867d\u975e\u5fc5\u987b\uff0c\u4f46\u4f5c\u4e3a\u597d\u4e60\u60ef)\n          e.stopPropagation();\n\n          const targetId = btn.getAttribute('data-sub-target');\n          \n          \/\/ \u79fb\u9664\u6240\u6709\u5b50\u6309\u94ae active\n          subBtns.forEach(b=>b.classList.remove('active'));\n          \/\/ \u9690\u85cf\u6240\u6709\u5b50\u9762\u677f\n          subPanels.forEach(p=>p.classList.remove('active'));\n\n          \/\/ \u6fc0\u6d3b\u5f53\u524d\u6309\u94ae\n          btn.classList.add('active');\n          \n          \/\/ \u6fc0\u6d3b\u5bf9\u5e94\u9762\u677f\n          const targetPanel = root.querySelector('#' + targetId);\n          if(targetPanel) {\n              targetPanel.classList.add('active');\n          }\n        });\n      });\n\n    })();\n  <\/script>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-1e07ea9\" data-block-id=\"1e07ea9\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-1e07ea9-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-899c150\" data-v=\"4\" data-block-id=\"899c150\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-899c150-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-899c150-inner-blocks\">\n<section id=\"sec4-dry-features\" style=\"background:#ffffff;padding:90px 0 100px;\">\n  <style>\n    #sec4-dry-features{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n    #sec4-dry-features .features-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec4-dry-features .sec-header{max-width:820px;margin:0 auto 40px;text-align:center;}\n    #sec4-dry-features .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec4-dry-features h2{font-size:28px;margin:0 0 10px;color:#0F172A;}\n    #sec4-dry-features .sec-header p{margin:0;font-size:15px;color:#4B5563;line-height:1.8;}\n\n    #sec4-dry-features .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n      margin-top:40px;\n    }\n\n    #sec4-dry-features .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:22px 22px 24px;\n      box-shadow:0 14px 32px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n\n    #sec4-dry-features .card h3{font-size:17px;margin:0 0 8px;color:#0F172A;}\n    #sec4-dry-features .card .tag{\n      display:inline-flex;\n      padding:3px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      background:#0F172A;\n      color:#E5E7EB;\n      margin-bottom:12px;\n    }\n\n    #sec4-dry-features .card p{font-size:14px;color:#374151;line-height:1.8;margin:0 0 10px;}\n    #sec4-dry-features .card ul{list-style:none;padding:0;margin:6px 0 0;font-size:14px;color:#4B5563;}\n    #sec4-dry-features .card li{\n      position:relative;\n      padding-left:16px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec4-dry-features .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    @media(max-width:1000px){\n      #sec4-dry-features .grid{grid-template-columns:repeat(2,minmax(0,1fr));}\n    }\n    @media(max-width:690px){\n      #sec4-dry-features .features-shell{padding:0 18px;}\n      #sec4-dry-features .grid{grid-template-columns:1fr;}\n      #sec4-dry-features h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"features-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Engineered for Indoor Safety<\/div>\n      <h2>Key Features of XBRELE Dry Type Transformers<\/h2>\n      <p>\n        XBRELE dry type transformers adopt cast resin and epoxy resin insulation with Class B, F, H and C systems, offering\n        high fire safety, low loss and reliable performance for indoor power distribution in high-rise buildings, tunnels,\n        commercial centers and public facilities.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n\n      <!-- Card 1 -->\n      <article class=\"card\">\n        <span class=\"tag\">Fire Safety<\/span>\n        <h3>Non-Combustible Insulation System<\/h3>\n        <p>\n          SCB and SC(B) series use flame-retardant resin systems with very low smoke emission, making them suitable for\n          critical locations where oil-filled transformers are restricted.\n        <\/p>\n        <ul>\n          <li><strong>Self-extinguishing resin:<\/strong> Non-combustible insulation with low smoke and toxicity.<\/li>\n          <li><strong>Indoor transformer design:<\/strong> Ideal for metro, hospitals, schools and commercial buildings.<\/li>\n          <li><strong>Fire resistant transformer choice:<\/strong> Helps meet modern building fire-safety codes.<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2 -->\n      <article class=\"card\">\n        <span class=\"tag\">Insulation &amp; Losses<\/span>\n        <h3>Cast Resin &amp; Epoxy Resin Technology<\/h3>\n        <p>\n          High-voltage windings are vacuum cast with epoxy resin or cast resin, ensuring excellent dielectric strength,\n          moisture resistance and stable temperature rise under different insulation classes.\n        <\/p>\n        <ul>\n          <li><strong>Insulation classes:<\/strong> Class B, F, H and C with reference hot-spot temperatures up to 220&nbsp;\u00b0C.<\/li>\n          <li><strong>Optimised loss values:<\/strong> No-load and load losses aligned with GB1094 and IEC&nbsp;60076-11.<\/li>\n          <li><strong>Stable performance:<\/strong> Suitable for 6\u201335&nbsp;kV dry type distribution transformer projects.<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3 -->\n      <article class=\"card\">\n        <span class=\"tag\">Reliability<\/span>\n        <h3>Robust Core &amp; Foil Winding Structure<\/h3>\n        <p>\n          The core adopts high-grade oriented silicon steel with step-lap joints, while the low-voltage winding uses\n          foil or multi-layer copper conductors for strong short-circuit withstand capability.\n        <\/p>\n        <ul>\n          <li><strong>Low partial discharge:<\/strong> Careful processing and vacuum casting reduce PD levels.<\/li>\n          <li><strong>Short-circuit strength:<\/strong> Compact winding structure improves mechanical reliability.<\/li>\n          <li><strong>Easy maintenance:<\/strong> Dry type design avoids oil treatment and simplifies routine inspection.<\/li>\n        <\/ul>\n      <\/article>\n\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-0f51749\" data-block-id=\"0f51749\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-0f51749-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-1c6b7cf\" data-v=\"4\" data-block-id=\"1c6b7cf\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-1c6b7cf-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-1c6b7cf-inner-blocks\">\n<section id=\"sec5-dry-quality\" style=\"background:#0B1220;padding:72px 0 78px;color:#E5E7EB;\">\n  <style>\n    \/* \u6837\u5f0f\u4fdd\u6301\u4e00\u81f4\uff0c\u4ec5\u5c06 ID \u4fee\u6539\u4e3a\u5e72\u5f0f\u53d8\u538b\u5668\u4e13\u7528 *\/\n    #sec5-dry-quality{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;}\n    #sec5-dry-quality .quality-shell{max-width:1500px;margin:0 auto;padding:0 5vw;}\n    #sec5-dry-quality .sec-header{max-width:820px;margin:0 auto 32px;text-align:center;}\n    #sec5-dry-quality .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec5-dry-quality h2{font-size:26px;margin:0 0 8px;color:#F9FAFB;}\n    #sec5-dry-quality .sec-header p{margin:0;font-size:14px;color:#CBD5F5;line-height:1.7;}\n    #sec5-dry-quality .grid{display:grid;grid-template-columns:minmax(0,1.2fr) minmax(0,1.05fr);gap:28px;align-items:flex-start;}\n\n    \/* \u5de6\u4fa7\u5de5\u827a\u6d41\u7a0b\u5361\u7247 *\/\n    #sec5-dry-quality .process-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:radial-gradient(circle at top left,rgba(56,189,248,.14) 0,rgba(15,23,42,.98) 36%,#020617 100%);\n      padding:22px 22px 24px;\n      box-shadow:0 22px 52px rgba(15,23,42,.9);\n    }\n    #sec5-dry-quality .process-card h3{font-size:17px;margin:0 0 8px;color:#E5F0FF;}\n    #sec5-dry-quality .process-card p{font-size:13.5px;color:#CBD5F5;line-height:1.75;margin:0 0 14px;}\n    #sec5-dry-quality .step-list{list-style:none;margin:0;padding:0;display:flex;flex-direction:column;gap:10px;}\n    #sec5-dry-quality .step{display:grid;grid-template-columns:auto minmax(0,1fr);gap:8px 12px;align-items:flex-start;}\n    #sec5-dry-quality .step-badge{\n      width:24px;height:24px;border-radius:999px;\n      border:1px solid rgba(148,163,184,.7);\n      display:flex;align-items:center;justify-content:center;\n      font-size:11px;font-weight:600;color:#E5E7EB;\n      background:rgba(15,23,42,.85);\n      flex-shrink:0;\n    }\n    #sec5-dry-quality .step h4{font-size:13.5px;margin:1px 0 3px;color:#F9FAFB;}\n    #sec5-dry-quality .step p{font-size:12.5px;margin:0;color:#CBD5F5;line-height:1.7;}\n\n    \/* \u53f3\u4fa7 QA \u6807\u51c6\u5361\u7247 *\/\n    #sec5-dry-quality .qa-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:rgba(15,23,42,.96);\n      padding:20px 20px 22px;\n      box-shadow:0 22px 52px rgba(15,23,42,.8);\n      border-top:3px solid #38BDF8;\n    }\n    #sec5-dry-quality .qa-label{font-size:11px;letter-spacing:.14em;text-transform:uppercase;color:#93C5FD;margin-bottom:3px;}\n    #sec5-dry-quality .qa-card h3{font-size:15px;margin:0 0 4px;color:#E5F0FF;}\n    #sec5-dry-quality .qa-card p{font-size:13px;color:#CBD5F5;margin:0 0 4px;line-height:1.65;}\n    #sec5-dry-quality .qa-block{margin-top:10px;padding-top:10px;border-top:1px solid rgba(148,163,184,.35);}\n    #sec5-dry-quality .qa-block:first-of-type{margin-top:6px;padding-top:0;border-top:none;}\n    #sec5-dry-quality .qa-block h4{font-size:13.5px;margin:0 0 3px;color:#E5F0FF;}\n    #sec5-dry-quality .qa-block ul{list-style:none;padding:0;margin:0;font-size:12.5px;color:#E5E7EB;}\n    #sec5-dry-quality .qa-block li{position:relative;padding-left:12px;margin-bottom:2px;line-height:1.6;}\n    #sec5-dry-quality .qa-block li::before{\n      content:\"\";position:absolute;left:0;top:7px;\n      width:5px;height:5px;border-radius:999px;background:#38BDF8;\n    }\n    #sec5-dry-quality .qa-note{font-size:12px;color:#9CA3AF;margin-top:4px;}\n\n    @media(max-width:1000px){#sec5-dry-quality .grid{grid-template-columns:1fr;}}\n    @media(max-width:690px){\n      #sec5-dry-quality .quality-shell{padding:0 18px;}\n      #sec5-dry-quality h2{font-size:22px;}\n    }\n  <\/style>\n\n  <div class=\"quality-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Quality Control<\/div>\n      <h2>Manufacturing &#038; Testing of Dry Type Transformers<\/h2>\n      <p>\n        XBRELE dry type transformers follow IEC 60076-11 and GB\/T 10228 requirements for insulation, temperature rise,\n        short-circuit strength and partial discharge levels\u2014ensuring safe indoor operation for 6\u201335&nbsp;kV networks.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- \u5de5\u827a\u6d41\u7a0b\uff08\u5de6\u4fa7\uff09 -->\n      <article class=\"process-card\">\n        <h3>Controlled Manufacturing Process<\/h3>\n        <p>\n          SCB \/ SC(B) \/ SGB series transformers are cast in controlled environments with vacuum drying, resin casting\n          and precision coil winding to guarantee stable dielectric performance and low partial discharge.\n        <\/p>\n\n        <ul class=\"step-list\">\n\n          <li class=\"step\">\n            <div class=\"step-badge\">01<\/div>\n            <div>\n              <h4>Core Processing<\/h4>\n              <p>High-grade oriented silicon steel is cut using CNC shearing and stacked with step-lap joints to reduce no-load loss.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">02<\/div>\n            <div>\n              <h4>Foil &#038; Layer Winding<\/h4>\n              <p>Low-voltage foil windings and high-voltage multi-layer coils are wound under tension for strong short-circuit withstand capability.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">03<\/div>\n            <div>\n              <h4>Vacuum Drying<\/h4>\n              <p>Coils are vacuum-dried to eliminate moisture, improving insulation resistance and long-term stability.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">04<\/div>\n            <div>\n              <h4>Resin Casting \/ Epoxy Casting<\/h4>\n              <p>High-voltage windings are cast with epoxy resin or cast resin under vacuum to reduce voids and partial discharge (PD).<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">05<\/div>\n            <div>\n              <h4>Final Assembly &#038; Temperature-Rise Run<\/h4>\n              <p>Transformers undergo assembly, terminal installation and simulated load temperature-rise tests before inspection.<\/p>\n            <\/div>\n          <\/li>\n\n        <\/ul>\n      <\/article>\n\n      <!-- \u8d28\u91cf\u6807\u51c6\uff08\u53f3\u4fa7\uff09 -->\n      <section class=\"qa-card\">\n        <div class=\"qa-section\">\n          <div class=\"qa-label\">QA Standards<\/div>\n          <h3>Routine &#038; Type Tests<\/h3>\n          <p>\n            All tests comply with IEC 60076-11 and GB\/T 10228 standards for cast-resin dry-type transformers.\n          <\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Electrical Tests<\/h4>\n          <ul>\n            <li><strong>Ratio &#038; polarity tests<\/strong> for all tapping positions.<\/li>\n            <li><strong>Load loss &#038; impedance<\/strong> measured at reference temperature.<\/li>\n            <li><strong>No-load loss<\/strong> aligned with SCB \/ SC(B) \/ SGB energy levels.<\/li>\n            <li><strong>Applied &#038; induced voltage tests<\/strong> on HV\/LV windings.<\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Insulation &#038; PD<\/h4>\n          <ul>\n            <li>Insulation resistance and tan&nbsp;\u03b4 measurements.<\/li>\n            <li><strong>Partial discharge:<\/strong> Must be &lt;10&nbsp;pC (dry type standard).<\/li>\n            <li>Resin curing quality and thermal stability checks.<\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Mechanical &#038; Appearance<\/h4>\n          <ul>\n            <li>Verification of short-circuit withstand capability.<\/li>\n            <li>Inspection of coil bonding, casting quality and support structures.<\/li>\n            <li>Final check of terminals, mounting frames and enclosure options.<\/li>\n          <\/ul>\n          <div class=\"qa-note\">\n            Type test reports and PD test records are available upon request for EPC or utility projects.\n          <\/div>\n        <\/div>\n      <\/section>\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-0459f5f\" data-block-id=\"0459f5f\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-0459f5f-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-010d777\" data-v=\"4\" data-block-id=\"010d777\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-010d777-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-010d777-inner-blocks\">\n<section id=\"sec6-dry-delivery\" style=\"background:#F9FAFB;padding:88px 0 96px;\">\n  <style>\n    \/* \u6837\u5f0f\u4fdd\u6301\u5168\u7ad9\u7edf\u4e00 *\/\n    #sec6-dry-delivery{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n    #sec6-dry-delivery .delivery-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec6-dry-delivery .sec-header{max-width:860px;margin:0 auto 40px;text-align:center;}\n    #sec6-dry-delivery .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec6-dry-delivery h2{font-size:28px;margin:0 0 10px;color:#0F172A;}\n    #sec6-dry-delivery .sec-header p{margin:0;font-size:15px;color:#4B5563;line-height:1.8;}\n    #sec6-dry-delivery .grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:24px;align-items:stretch;}\n    #sec6-dry-delivery .card{border-radius:20px;border:1px solid #E5E7EB;background:#FFFFFF;padding:20px 20px 22px;box-shadow:0 16px 34px rgba(15,23,42,.04);display:flex;flex-direction:column;height:100%;}\n    #sec6-dry-delivery .card-label{font-size:11px;letter-spacing:.14em;text-transform:uppercase;color:#6B7280;margin-bottom:6px;}\n    #sec6-dry-delivery .card h3{font-size:17px;margin:0 0 8px;color:#0F172A;}\n    #sec6-dry-delivery .card p{font-size:14px;color:#4B5563;line-height:1.8;margin:0 0 10px;}\n    #sec6-dry-delivery .card ul{list-style:none;padding:0;margin:4px 0 0;font-size:13.5px;color:#374151;}\n    #sec6-dry-delivery .card li{position:relative;padding-left:14px;margin-bottom:6px;line-height:1.7;}\n    #sec6-dry-delivery .card li::before{content:\"\";position:absolute;left:0;top:7px;width:6px;height:6px;border-radius:999px;background:#38BDF8;}\n    #sec6-dry-delivery .cta-row{margin-top:32px;display:flex;justify-content:center;}\n    #sec6-dry-delivery .cta-btn{display:inline-block;padding:11px 30px;border-radius:8px;background:#0F172A;color:#F9FAFB;font-size:15px;font-weight:600;text-decoration:none;letter-spacing:.03em;box-shadow:0 12px 28px rgba(15,23,42,.2);transition:all .25s ease;white-space:nowrap;}\n    #sec6-dry-delivery .cta-btn:hover{background:#1F2937;box-shadow:0 16px 32px rgba(15,23,42,.28);transform:translateY(-1px);}\n    @media(max-width:1000px){#sec6-dry-delivery .grid{grid-template-columns:repeat(2,minmax(0,1fr));}}\n    @media(max-width:690px){#sec6-dry-delivery .delivery-shell{padding:0 18px;}#sec6-dry-delivery .grid{grid-template-columns:1fr;}#sec6-dry-delivery h2{font-size:24px;}}\n  <\/style>\n\n  <div class=\"delivery-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Delivery &amp; Project Support<\/div>\n      <h2>Reliable Supply Chain for Dry Type Transformers<\/h2>\n      <p>\n        From standard <strong>11&nbsp;kV dry type transformers<\/strong> to customised SCB \/ SC(B) \/ SGB solutions,\n        XBRELE coordinates production, packing and logistics so your dry type distribution transformers arrive on time\n        and ready for indoor installation.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <article class=\"card\">\n        <div class=\"card-label\">Lead Time<\/div>\n        <h3>Flexible Production for SCB \/ SC(B) \/ SGB<\/h3>\n        <p>\n          Our dry type transformer lines support both standard catalogue ratings and project-based designs, helping EPCs\n          and end users meet substation and building schedules.\n        <\/p>\n        <ul>\n          <li><strong>Standard dry type transformers:<\/strong> Typical lead time around 30\u201345 days for common 6\u201311&nbsp;kV ratings.<\/li>\n          <li><strong>Special voltage \/ enclosure options:<\/strong> Approx. 45\u201360 days depending on insulation class and protection degree.<\/li>\n          <li><strong>Project batches:<\/strong> Coordinated production for multi-set deliveries on large building or metro projects.<\/li>\n          <li><strong>Spare units:<\/strong> Recommended safety stock schemes for key <strong>dry type distribution transformer<\/strong> sizes.<\/li>\n        <\/ul>\n      <\/article>\n\n      <article class=\"card\">\n        <div class=\"card-label\">Packing &amp; Logistics<\/div>\n        <h3>Protection for Indoor Equipment<\/h3>\n        <p>\n          Although dry type transformers are oil-free, they still require robust protection during transport, especially\n          for cast resin windings, terminals and enclosures.\n        <\/p>\n        <ul>\n          <li><strong>Export wooden pallets \/ crates:<\/strong> Fumigated and reinforced for transformer weight and dimensions.<\/li>\n          <li><strong>Moisture control:<\/strong> Film wrapping and desiccant bags to protect core and coils during sea shipment.<\/li>\n          <li><strong>Shock protection:<\/strong> Extra padding around HV\/LV terminals and epoxy resin coils.<\/li>\n          <li><strong>Clear identification:<\/strong> Nameplate, rating and <strong>dry type transformer<\/strong> model labels for easy site handling.<\/li>\n        <\/ul>\n      <\/article>\n\n      <article class=\"card\">\n        <div class=\"card-label\">Engineering Support<\/div>\n        <h3>Installation &amp; Commissioning Assistance<\/h3>\n        <p>\n          XBRELE provides technical support for installing and operating dry type transformers in indoor substations,\n          commercial buildings and infrastructure projects.\n        <\/p>\n        <ul>\n          <li><strong>Installation guidelines:<\/strong> Recommendations on clearances, ventilation and enclosure selection for SCB \/ SC(B) \/ SGB units.<\/li>\n          <li><strong>Commissioning support:<\/strong> Guidance on insulation resistance, ratio and partial discharge checks before energising.<\/li>\n          <li><strong>Maintenance advice:<\/strong> Periodic inspection procedures for resin surfaces, terminals and cooling air paths.<\/li>\n          <li><strong>Remote &amp; document support:<\/strong> Drawings, test reports and Q&amp;A support for consultants and EPC contractors.<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n\n    <div class=\"cta-row\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Get a Quote &amp; Lead Time for Dry Type Transformers\n      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-baa6733\" data-block-id=\"baa6733\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-baa6733-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-1265a49\" data-v=\"4\" data-block-id=\"1265a49\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-1265a49-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-1265a49-inner-blocks\">\n<section id=\"sec7-dry-faq\" style=\"padding:80px 0 100px;background:#ffffff;\">\n  <style>\n    #sec7-dry-faq{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n\n    \/* Optimized container width *\/\n    #sec7-dry-faq .faq-shell{max-width:1200px;margin:0 auto;padding:0 5vw;}\n\n    #sec7-dry-faq .faq-header{max-width:900px;margin:0 auto 48px;text-align:center;}\n    #sec7-dry-faq .faq-kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;background:#F0F9FF;padding:4px 12px;border-radius:99px;color:#0284C7;margin-bottom:10px;display:inline-block;}\n    #sec7-dry-faq h2{font-size:30px;margin:0 0 14px;color:#0F172A;line-height:1.2;}\n    #sec7-dry-faq .faq-header p{margin:0 auto;font-size:16px;color:#4B5563;line-height:1.7;max-width:750px;}\n\n    \/* Grid Layout Optimization *\/\n    #sec7-dry-faq .faq-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:20px;align-items:flex-start;}\n\n    #sec7-dry-faq details{border-radius:12px;border:1px solid #E2E8F0;background:#FFFFFF;padding:20px 24px;transition:all .2s ease;box-shadow:0 2px 4px rgba(0,0,0,0.02);}\n    #sec7-dry-faq details:hover{border-color:#CBD5E1;box-shadow:0 4px 12px rgba(0,0,0,0.04);}\n    #sec7-dry-faq details[open]{background:#F8FAFC;border-color:#CBD5E1;}\n\n    #sec7-dry-faq summary{list-style:none;cursor:pointer;font-size:16px;font-weight:600;color:#1E293B;display:flex;justify-content:space-between;align-items:center;line-height:1.5;}\n    #sec7-dry-faq summary::-webkit-details-marker{display:none;}\n\n    #sec7-dry-faq .faq-icon{flex-shrink:0;width:24px;height:24px;border-radius:99px;background:#F1F5F9;color:#64748B;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:bold;margin-left:12px;}\n    #sec7-dry-faq details[open] .faq-icon{background:#2563EB;color:#FFFFFF;transform:rotate(45deg);}\n\n    #sec7-dry-faq .faq-answer{margin-top:12px;font-size:15px;color:#475569;line-height:1.75;}\n\n    @media(max-width:690px){\n      #sec7-dry-faq .faq-grid{grid-template-columns:1fr;}\n      #sec7-dry-faq h2{font-size:24px;}\n      #sec7-dry-faq details{padding:16px;}\n    }\n  <\/style>\n\n  <div class=\"faq-shell\">\n    <div class=\"faq-header\">\n      <div class=\"faq-kicker\">FAQ \u00b7 Dry Type Transformers<\/div>\n      <h2>Common Questions About Dry Type Transformers<\/h2>\n      <p>\n        These are the most frequent questions about <strong>Dry Type Transformers<\/strong>, including performance, safety, applications, and international standards.\n      <\/p>\n    <\/div>\n\n    <div class=\"faq-grid\">\n      \n      <!-- Q1 -->\n      <details open>\n        <summary>\n          <span>What is a Dry Type Transformer?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          A <strong>Dry Type Transformer<\/strong> uses air or resin for insulation instead of oil. \n          The windings are either vacuum-pressure impregnated (VPI) or cast in epoxy resin (as in SCB10, SCB11, SCB13). \n          These transformers are widely used in commercial buildings, substations, industrial plants, and fire-risk environments.\n        <\/div>\n      <\/details>\n\n      <!-- Q2 -->\n      <details>\n        <summary>\n          <span>What are the advantages of Dry Type Transformers?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Dry type transformers offer strong environmental safety (no oil leakage), low maintenance, and excellent fire resistance.  \n          Cast-resin types such as <strong>SCB10 \/ SCB11 \/ SCB13<\/strong> are highly resistant to moisture and chemicals, making them suitable for coastal, humid, or demanding industrial sites.\n        <\/div>\n      <\/details>\n\n      <!-- Q3 -->\n      <details>\n        <summary>\n          <span>Where are Dry Type Transformers typically used?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          They are ideal for indoor applications, commercial complexes, hospitals, schools, tunnels, airports, high-rise buildings, or areas with strict fire-safety requirements.  \n          Cast-resin models also perform well in environments with high humidity or airborne contaminants.\n        <\/div>\n      <\/details>\n\n      <!-- Q4 -->\n      <details>\n        <summary>\n          <span>How long is the lifespan of a Dry Type Transformer?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          The typical service life is <strong>20\u201330 years<\/strong>, depending on load conditions, installation quality, and ambient temperature.  \n          Resin-cast models generally last longer due to improved thermal performance and coil protection.\n        <\/div>\n      <\/details>\n\n      <!-- Q5 -->\n      <details>\n        <summary>\n          <span>Do Dry Type Transformers require maintenance?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Yes, but much less than an oil-based transformer.  \n          Key maintenance tasks include:\n          <ul style=\"margin-top:8px;\">\n            <li>Cleaning the windings and enclosure<\/li>\n            <li>Checking temperature rise and ventilation<\/li>\n            <li>Inspecting terminals and tightening connections<\/li>\n            <li>Infrared thermal scanning for hotspots<\/li>\n          <\/ul>\n          No oil testing or oil purification is required.\n        <\/div>\n      <\/details>\n\n      <!-- Q6 -->\n      <details>\n        <summary>\n          <span>Which standards apply to Dry Type Transformers?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Dry type transformers are tested under international standards such as  \n          <strong>IEC 60076-11<\/strong> (dry type), <strong>IEC 60076-5<\/strong> (short-circuit strength), and <strong>IEC 60076-7<\/strong> (loading guide).  \n          Reference:  \n          <a href=\"https:\/\/www.iec.ch\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#2563EB;text-decoration:underline;\">\n            IEC official documentation\n          <\/a>\n        <\/div>\n      <\/details>\n\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u0935\u093e\u0923\u093f\u091c\u094d\u092f\u093f\u0915 \u0914\u0930 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0921\u094d\u0930\u093e\u0908-\u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0938\u092e\u093e\u0927\u093e\u0928, \u091c\u093f\u0928\u092e\u0947\u0902 \u0915\u093e\u0938\u094d\u091f \u0930\u0947\u091c\u093c\u093f\u0928 \u0935\u093f\u0915\u0932\u094d\u092a, \u092e\u093e\u0928\u0915 \u0930\u0947\u091f\u093f\u0902\u0917, \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0914\u0930 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0938\u0939\u093e\u092f\u0924\u093e \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/p>","protected":false},"author":1,"featured_media":0,"parent":1304,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1333","page","type-page","status-publish","hentry"],"blocksy_meta":{"vertical_spacing_source":"custom","content_area_spacing":"none","has_hero_section":"disabled","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=1333"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1333\/revisions"}],"predecessor-version":[{"id":3837,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1333\/revisions\/3837"}],"up":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1304"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=1333"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}