{"id":1967,"date":"2025-12-04T13:54:32","date_gmt":"2025-12-04T13:54:32","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1967"},"modified":"2025-12-04T15:07:56","modified_gmt":"2025-12-04T15:07:56","slug":"switchgear-component-manufacturer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/hi\/switchgear-component-manufacturer\/","title":{"rendered":"\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e"},"content":{"rendered":"<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-3a5b1c3\" data-block-id=\"3a5b1c3\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-3a5b1c3-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-155ceae\" data-v=\"4\" data-block-id=\"155ceae\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-155ceae-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-155ceae-inner-blocks\">\n<style>\n    \/* --- XBRELE PRO STYLE SYSTEM (v5.1 - Component Edition) --- *\/\n    \n    .xbrele-pro-page {\n        font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        color: #111;\n        line-height: 1.7; \n        font-size: 18px; \n        font-weight: 400;\n        background-color: #fff;\n    }\n\n    .xbrele-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        padding: 0 20px;\n    }\n\n    .xbrele-section {\n        padding: 60px 0;\n        border-bottom: 1px solid #f0f0f0;\n    }\n    .xbrele-section.bg-light {\n        background-color: #f8fbfb;\n    }\n\n    .xbrele-pro-page h1 {\n        font-size: 42px;\n        font-weight: 800;\n        text-align: center;\n        margin-bottom: 30px;\n        color: #000;\n        letter-spacing: -0.5px;\n    }\n    \n    .xbrele-pro-page h2 {\n        font-size: 30px;\n        color: #000;\n        margin-top: 50px;\n        margin-bottom: 25px;\n        position: relative;\n        padding-left: 20px;\n        border-left: 8px solid #009688; \/* XBRELE Teal *\/\n        font-weight: 700;\n        text-transform: uppercase;\n    }\n    \n    .xbrele-pro-page h3 {\n        font-size: 22px;\n        font-weight: 700;\n        margin-top: 35px;\n        margin-bottom: 15px;\n        color: #009688;\n    }\n\n    .xbrele-pro-page p {\n        margin-bottom: 25px;\n        color: #222;\n        text-align: justify;\n    }\n\n    \/* Hero \u56fe\u7247\u6837\u5f0f *\/\n    .xbrele-hero-img {\n        width: 100%;\n        height: auto;\n        border-radius: 6px;\n        margin-bottom: 40px;\n        box-shadow: 0 4px 12px rgba(0,0,0,0.1);\n        display: block;\n    }\n\n    .xbrele-list {\n        list-style: none;\n        padding: 0;\n        margin-bottom: 30px;\n    }\n    .xbrele-list li {\n        position: relative;\n        padding-left: 30px;\n        margin-bottom: 12px;\n        color: #222;\n    }\n    .xbrele-list li::before {\n        content: \"\u25a0\";\n        position: absolute;\n        left: 0;\n        color: #009688;\n        font-size: 14px;\n        top: 6px;\n    }\n\n    .xbrele-tech-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 40px 0;\n        box-shadow: 0 5px 15px rgba(0,0,0,0.05);\n        font-size: 16px;\n    }\n    .xbrele-tech-table th, .xbrele-tech-table td {\n        padding: 18px;\n        border: 1px solid #ddd;\n    }\n    .xbrele-tech-table th {\n        background-color: #009688;\n        color: #fff;\n        font-weight: 700;\n        text-align: left;\n    }\n    .xbrele-tech-table tr:nth-child(even) {\n        background-color: #fcfcfc;\n    }\n\n    .xbrele-link {\n        color: #009688;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid rgba(0,150,136,0.2);\n        transition: all 0.2s;\n    }\n    .xbrele-link:hover {\n        background-color: rgba(0,150,136,0.1);\n        border-bottom-color: #009688;\n    }\n\n    .xbrele-ext-link {\n        color: #555;\n        text-decoration: underline;\n        font-style: italic;\n    }\n\n    .xbrele-cta-box {\n        background: linear-gradient(135deg, #009688 0%, #004d40 100%);\n        color: #fff;\n        padding: 60px;\n        border-radius: 8px;\n        text-align: center;\n        margin-top: 60px;\n    }\n    .xbrele-cta-btn {\n        display: inline-block;\n        background-color: #fff;\n        color: #009688 !important;\n        padding: 18px 45px;\n        font-weight: 800;\n        text-transform: uppercase;\n        border-radius: 4px;\n        text-decoration: none;\n        margin-top: 25px;\n        font-size: 18px;\n        box-shadow: 0 4px 6px rgba(0,0,0,0.2);\n    }\n    .xbrele-cta-btn:hover {\n        background-color: #f4f4f4;\n        transform: translateY(-2px);\n    }\n<\/style>\n\n<div class=\"xbrele-pro-page\">\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h1>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0914\u0930 \u0913\u0908\u090f\u092e \u0938\u092e\u093e\u0927\u093e\u0928<\/h1>\n            \n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/switchgear-component-manufacturing-factory.webp\" \n                 alt=\"XBRELE \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u092b\u0948\u0915\u094d\u091f\u0930\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0915\u094d\u0938\u094b\u0902 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f\" \n                 class=\"xbrele-hero-img\" \/>\n\n            <p>\n                \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0935\u0939 \u0906\u0927\u093e\u0930\u092d\u0942\u0924 \u0909\u0926\u094d\u092f\u094b\u0917 \u0939\u0948 \u091c\u094b \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c (MV) \u0914\u0930 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c (HV) \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0940 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0915\u094b \u0936\u0915\u094d\u0924\u093f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0938\u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u201c\u0928\u093f\u0937\u094d\u0915\u094d\u0930\u093f\u092f\u201d \u092d\u093e\u0917\u094b\u0902\u2014\u091c\u0948\u0938\u0947 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928, \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938\u2014\u0915\u0940 \u0938\u091f\u0940\u0915 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948, \u091c\u094b KYN28, XGN \u0914\u0930 \u0930\u093f\u0902\u0917 \u092e\u0947\u0928 \u092f\u0942\u0928\u093f\u091f\u094d\u0938 (RMU) \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0937\u092e\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u090f\u0915 \u0938\u092e\u0930\u094d\u092a\u093f\u0924 <strong>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e<\/strong>, XBRELE \u0935\u093f\u0936\u094d\u0935\u092d\u0930 \u0915\u0947 \u092a\u0948\u0928\u0932 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0926\u0943\u0936\u094d\u092f \u0930\u0940\u0922\u093c \u0915\u0940 \u0939\u0921\u094d\u0921\u0940 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u093e \u0939\u0948\u0964 12kV \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0915\u094d\u0938\u094b\u0902 \u0938\u0947 \u0932\u0947\u0915\u0930 40.5kV \u0935\u0949\u0932 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0924\u0915, \u0939\u092e \u0906\u0935\u0936\u094d\u092f\u0915 \u0906\u0927\u093e\u0930\u092d\u0942\u0924 \u0918\u091f\u0915 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b OEMs \u0915\u094b \u0915\u0941\u0936\u0932\u0924\u093e \u0914\u0930 \u0906\u0924\u094d\u092e\u0935\u093f\u0936\u094d\u0935\u093e\u0938 \u0915\u0947 \u0938\u093e\u0925 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f, IEC-\u0905\u0928\u0941\u092a\u093e\u0932\u0915 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0938\u0947\u0902\u092c\u0932 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0938\u0915\u094d\u0937\u092e \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/h2>\n            <p>\n                \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915\u094b\u0902 \u0915\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0940 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0935\u093f\u0935\u093f\u0927 \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 \u092a\u0949\u0932\u093f\u092e\u0930 \u0930\u0938\u093e\u092f\u0928 \u0935\u093f\u091c\u094d\u091e\u093e\u0928 \u0914\u0930 \u0927\u093e\u0924\u0941 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0928\u094b\u0902 \u092e\u0947\u0902 \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e\u0924\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 XBRELE \u092e\u0947\u0902, \u0939\u092e\u093e\u0930\u0940 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0932\u093e\u0907\u0928\u0947\u0902 \u0907\u0928 \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u092d\u093e\u091c\u093f\u0924 \u0939\u0948\u0902, \u0938\u093e\u0925 \u0939\u0940 \u0905\u0902\u0924\u093f\u092e \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u092e\u0947\u0902 \u0928\u093f\u0930\u094d\u092c\u093e\u0927 \u090f\u0915\u0940\u0915\u0930\u0923 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                <strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u094b\u0932\u094d\u0921\u093f\u0902\u0917 (\u090f\u092a\u0940\u091c\u0940 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e):<\/strong> \u0915\u0947 \u0932\u093f\u090f <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/contact-box\/\" class=\"xbrele-link\">\u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0915\u094d\u0938\u0947 (\u0928\u093f\u0915\u093e\u0938)<\/a> \u0914\u0930 \u0935\u0949\u0932 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e \u0911\u091f\u094b\u092e\u0947\u091f\u093f\u0915 \u092a\u094d\u0930\u0947\u0936\u0930 \u091c\u0947\u0932\u0947\u0936\u0928 (APG) \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u092e\u0947\u0902 \u0935\u093e\u092f\u0941 \u092c\u0941\u0932\u092c\u0941\u0932\u094b\u0902 \u0915\u094b \u0939\u091f\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0947 \u0924\u0939\u0924 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093c\u093f\u0928 \u0915\u094b \u0938\u093f\u0932\u093f\u0915\u093e \u0939\u093e\u0930\u094d\u0921\u0928\u0930 \u0915\u0947 \u0938\u093e\u0925 \u092a\u0942\u0930\u094d\u0935-\u092e\u093f\u0936\u094d\u0930\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u092b\u093f\u0930 \u092e\u093f\u0936\u094d\u0930\u0923 \u0915\u094b \u0917\u0930\u094d\u092e \u0915\u093f\u090f \u0917\u090f \u0938\u094d\u091f\u0940\u0932 \u0915\u0947 \u0938\u093e\u0902\u091a\u094b\u0902 \u092e\u0947\u0902 \u0907\u0902\u091c\u0947\u0915\u094d\u091f \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0924\u0915\u0928\u0940\u0915 \u0909\u091a\u094d\u091a \u0906\u092f\u093e\u092e\u0940 \u0938\u091f\u0940\u0915\u0924\u093e \u0914\u0930 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948, \u091c\u094b \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.\n            <\/p>\n            <p>\n                <strong>\u0927\u093e\u0924\u0941 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u090f\u0935\u0902 \u092e\u0936\u0940\u0928\u0940\u0915\u0930\u0923:<\/strong> \u091c\u0948\u0938\u0947 \u0918\u091f\u0915 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/earthing-switch\/\" class=\"xbrele-link\">\u091c\u0947\u090f\u092815 \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a<\/a> \u0914\u0930 VCB \u091a\u0947\u0938\u093f\u0938 \u091f\u094d\u0930\u0915\u094b\u0902 \u0915\u094b \u092e\u091c\u092c\u0942\u0924 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e\u0913\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0939\u092e \u0909\u091a\u094d\u091a-\u092e\u091c\u092c\u0942\u0924 \u0938\u094d\u091f\u0940\u0932 \u0915\u094b CNC \u092a\u0902\u091a\u093f\u0902\u0917 \u0914\u0930 \u092c\u0947\u0902\u0921\u093f\u0902\u0917 \u092e\u0936\u0940\u0928\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0938\u0902\u0938\u093e\u0927\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u093e\u0915\u093f \u0910\u0938\u0947 \u092b\u094d\u0930\u0947\u092e \u0924\u0948\u092f\u093e\u0930 \u0915\u093f\u090f \u091c\u093e \u0938\u0915\u0947\u0902 \u091c\u094b \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f (40kA \u0924\u0915) \u0915\u0947 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u0921\u093e\u092f\u0928\u093e\u092e\u093f\u0915 \u092c\u0932\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930 \u0938\u0915\u0947\u0902\u0964 \u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0924\u093e\u0902\u092c\u0947 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u091a\u093e\u0902\u0926\u0940 \u0915\u0940 \u092a\u0930\u0924 \u091a\u0922\u093c\u093e\u0908 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.\n            <\/p>\n            <p>\n                <strong>\u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0914\u0930 \u090f\u0915\u0940\u0915\u0930\u0923:<\/strong> \u0905\u0902\u0924\u093f\u092e \u091a\u0930\u0923 \u092e\u0947\u0902 \u092c\u0939\u0941-\u092d\u093e\u0917 \u0924\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u0940 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u0948\u0938\u0947 \u0915\u093f <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/switchgear-components\/\" class=\"xbrele-link\">\u092a\u093e\u0901\u091a-\u0930\u094b\u0915\u0925\u093e\u092e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938<\/a>. \u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u0932\u0940\u0935\u0930\u094d\u0938 \u0914\u0930 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u092e\u0948\u0917\u094d\u0928\u0947\u091f \u0905\u0938\u0947\u0902\u092c\u0932 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0932\u0949\u091c\u093f\u0915 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u093e\u0915\u093f \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0911\u092a\u0930\u0947\u091f\u0930 \u0915\u094b\u0908 \u0916\u0924\u0930\u0928\u093e\u0915 \u0917\u0932\u0924\u0940 \u0928 \u0915\u0930 \u0938\u0915\u0947 (\u091c\u0948\u0938\u0947 \u0932\u093e\u0907\u0935 \u092c\u0938\u092c\u093e\u0930 \u092a\u0930 \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a \u092c\u0902\u0926 \u0915\u0930\u0928\u093e)\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0918\u091f\u0915 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u092e\u0947\u0902 \u092a\u094d\u0930\u092f\u0941\u0915\u094d\u0924 \u0915\u091a\u094d\u091a\u0947 \u092e\u093e\u0932<\/h2>\n            <p>\n                \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0948\u0928\u0932 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0907\u0938\u0915\u0947 \u0938\u092c\u0938\u0947 \u091b\u094b\u091f\u0947 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u0915\u091a\u094d\u091a\u0940 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0938\u0947 \u0936\u0941\u0930\u0942 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 XBRELE \u0915\u0947\u0935\u0932 \u092a\u094d\u0930\u092e\u093e\u0923\u093f\u0924 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 \u0924\u093e\u0915\u093f \u0926\u0940\u0930\u094d\u0918\u093e\u092f\u0941 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b \u0938\u0915\u0947\u0964.\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093c\u093f\u0928 \u0938\u093f\u0938\u094d\u091f\u092e:<\/strong> \u0939\u092e \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e \u092c\u093f\u0938\u094d\u092b\u0947\u0928\u0949\u0932-\u090f \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093c\u093f\u0928 \u0915\u094b \u0909\u091a\u094d\u091a-\u0936\u0941\u0926\u094d\u0927\u0924\u093e \u0938\u093f\u0932\u093f\u0915\u093e \u092a\u093e\u0909\u0921\u0930 \u0915\u0947 \u0938\u093e\u0925 \u092e\u093f\u0932\u093e\u0915\u0930 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092b\u0949\u0930\u094d\u092e\u0942\u0932\u0947\u0936\u0928 \u0909\u091a\u094d\u091a \u0917\u094d\u0932\u093e\u0938 \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u0936\u0928 \u0924\u093e\u092a\u092e\u093e\u0928 (Tg &gt; 110\u00b0C) \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u0917\u0930\u094d\u092e \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u092d\u0940 \u0938\u094d\u0925\u093f\u0930 \u0930\u0939\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n                <li><strong>\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u0932\u093e\u0907\u091f\u093f\u0915 \u0924\u093e\u0902\u092c\u093e (T2):<\/strong> \u0938\u092d\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0935\u093e\u0939\u0915 \u092d\u093e\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u091c\u0948\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0949\u0915\u094d\u0938 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u0947 \u0938\u094d\u0925\u093f\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a \u0915\u0940 \u092c\u094d\u0932\u0947\u0921\u094d\u0938, \u0939\u092e \u091a\u093e\u0932\u0915\u0924\u093e \u0915\u094b \u0905\u0927\u093f\u0915\u0924\u092e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f T2 \u0924\u093e\u0902\u092c\u093e (99.9% \u0936\u0941\u0926\u094d\u0927\u0924\u093e) \u092a\u0930 8\u201312 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u092e\u0940\u091f\u0930 \u091a\u093e\u0902\u0926\u0940 \u0915\u0940 \u092a\u0930\u0924 \u091a\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n                <li><strong>\u0915\u094b\u0932\u094d\u0921 \u0930\u094b\u0932\u094d\u0921 \u0938\u094d\u091f\u0940\u0932 (SPCC):<\/strong> \u092f\u0947 \u092d\u093e\u0917 \u091a\u0947\u0938\u093f\u0938 \u091f\u094d\u0930\u0915\u094b\u0902 \u0914\u0930 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u093f\u0902\u0917 \u0924\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u090f \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0928 \u092d\u093e\u0917\u094b\u0902 \u092a\u0930 \u091c\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091c\u093f\u0902\u0915 \u092f\u093e \u0928\u093f\u0915\u0932 \u0915\u0940 \u092a\u094d\u0932\u0947\u091f\u093f\u0902\u0917 \u0915\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948, \u091c\u094b 72 \u0918\u0902\u091f\u0947 \u0915\u0947 \u0938\u0949\u0932\u094d\u091f \u0938\u094d\u092a\u094d\u0930\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094b \u092a\u093e\u0938 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/li>\n                <li><strong>\u092a\u0949\u0932\u0940\u0915\u093e\u0930\u094d\u092c\u094b\u0928\u0947\u091f (\u092a\u0940\u0938\u0940) \u0914\u0930 \u0928\u093e\u092f\u0932\u0949\u0928:<\/strong> \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0902\u0915\u0947\u0924\u0915 \u0914\u0930 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u092a\u094d\u0932\u0917 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e \u0928\u093f\u092e\u094d\u0928-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f \u092e\u0947\u0902 \u0905\u0917\u094d\u0928\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0939\u0947\u0924\u0941 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0925\u0930\u094d\u092e\u094b\u092a\u094d\u0932\u093e\u0938\u094d\u091f\u093f\u0915 (UL94 V-0 \u0917\u094d\u0930\u0947\u0921) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0906\u0935\u0936\u094d\u092f\u0915 \u0935\u093f\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0909\u092a\u0915\u0930\u0923<\/h2>\n            <p>\n                \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915\u094b\u0902 \u0915\u093e \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u092c\u0939\u0941\u092e\u0941\u0916\u0940 \u0915\u093e\u0930\u0916\u093e\u0928\u093e \u092b\u0930\u094d\u0936 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 XBRELE \u0928\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0926\u094b\u0928\u094b\u0902 \u092d\u093e\u0917\u094b\u0902 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u092e\u0936\u0940\u0928\u0930\u0940 \u092e\u0947\u0902 \u0928\u093f\u0935\u0947\u0936 \u0915\u093f\u092f\u093e \u0939\u0948\u0964.\n            <\/p>\n            <p>\n                <strong>\u090f\u092a\u0940\u091c\u0940 \u0915\u094d\u0932\u0948\u0902\u092a\u093f\u0902\u0917 \u092e\u0936\u0940\u0928\u0947\u0902:<\/strong> \u0939\u092e\u093e\u0930\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e\u0930\u094d\u092f\u0936\u093e\u0932\u093e \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u0932\u093f\u0915 APG \u0915\u094d\u0932\u0948\u0902\u092a\u093f\u0902\u0917 \u092e\u0936\u0940\u0928\u094b\u0902 \u0938\u0947 \u0938\u0941\u0938\u091c\u094d\u091c\u093f\u0924 \u0939\u0948\u0964 \u092f\u0947 \u0939\u092e\u0947\u0902 \u091c\u091f\u093f\u0932 \u0906\u0915\u0943\u0924\u093f\u092f\u094b\u0902 \u0915\u094b \u0906\u0915\u093e\u0930 \u0926\u0947\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948\u0902, \u091c\u0948\u0938\u0947 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/post-insulator\/\" class=\"xbrele-link\">\u092a\u094b\u0938\u094d\u091f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930<\/a> \u090f\u0915 \u0939\u0940 \u091a\u0915\u094d\u0930 \u092e\u0947\u0902 \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0939\u093f\u0924 \u0925\u094d\u0930\u0947\u0921\u0947\u0921 \u0907\u0928\u094d\u0938\u0930\u094d\u091f\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925, \u091c\u094b \u0909\u091a\u094d\u091a \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u0941\u0932-\u0906\u0909\u091f \u092e\u091c\u092c\u0942\u0924\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                <strong>\u0938\u0940\u090f\u0928\u0938\u0940 \u091f\u0930\u0947\u091f \u092a\u0902\u091a \u0914\u0930 \u0932\u0947\u091c\u093c\u0930:<\/strong> \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0914\u0930 \u091a\u0947\u0938\u093f\u0938 \u0915\u0947 \u0932\u093f\u090f \u0938\u091f\u0940\u0915\u0924\u093e \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0948\u0915-\u0907\u0928\/\u0930\u0948\u0915-\u0906\u0909\u091f \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0915\u0941\u0902\u091c\u0940 \u0939\u0948\u0964 \u0939\u092e\u093e\u0930\u0947 \u0938\u0940\u090f\u0928\u0938\u0940 \u0915\u0947\u0902\u0926\u094d\u0930 0.1 \u092e\u093f\u092e\u0940 \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u0938\u094d\u091f\u0940\u0932 \u092a\u094d\u0932\u0947\u091f\u0947\u0902 \u0915\u093e\u091f\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0939\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u092d\u093e\u0917 \u092c\u093f\u0928\u093e \u092b\u093e\u0907\u0932\u093f\u0902\u0917 \u092f\u093e \u0917\u094d\u0930\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0915\u0947 \u092a\u0948\u0928\u0932 \u092e\u0947\u0902 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u092b\u093f\u091f \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.\n            <\/p>\n            <p>\n                <strong>\u0938\u0924\u0939 \u0909\u092a\u091a\u093e\u0930 \u0932\u093e\u0907\u0928\u0947\u0902:<\/strong> \u091c\u092c\u0915\u093f \u0905\u0915\u094d\u0938\u0930 \u091b\u094b\u091f\u0940 \u0915\u093e\u0930\u094d\u092f\u0936\u093e\u0932\u093e\u0913\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0906\u0909\u091f\u0938\u094b\u0930\u094d\u0938 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948, XBRELE \u0905\u092a\u0928\u0947 \u0938\u093f\u0932\u094d\u0935\u0930-\u092a\u094d\u0932\u0947\u091f\u093f\u0902\u0917 \u0914\u0930 \u091c\u093f\u0902\u0915-\u092a\u094d\u0932\u0947\u091f\u093f\u0902\u0917 \u0938\u093e\u091d\u0947\u0926\u093e\u0930\u094b\u0902 \u092a\u0930 \u0915\u0921\u093c\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948 \u0924\u093e\u0915\u093f \u092e\u094b\u091f\u093e\u0908 \u0914\u0930 \u091a\u093f\u092a\u0915\u0928 \u0906\u0930\u094d\u0926\u094d\u0930 \u0909\u0937\u094d\u0923\u0915\u091f\u093f\u092c\u0902\u0927\u0940\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f IEC \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0947\u0902\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915\u094b\u0902 \u0915\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/h2>\n            <p>\n                \u090f\u0915 \u092d\u0940 \u0926\u094b\u0937\u092a\u0942\u0930\u094d\u0923 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u0938\u0902\u092a\u0942\u0930\u094d\u0923 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0907\u0938\u0932\u093f\u090f, XBRELE IEC 60694 \u0914\u0930 IEC 62271-102 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0938\u092d\u0940 \u0918\u091f\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u201c\u0936\u0942\u0928\u094d\u092f \u0926\u094b\u0937\u201d \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u0940\u0924\u093f \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.\n            <\/p>\n            \n            <table class=\"xbrele-tech-table\">\n                <tr>\n                    <th>\u092a\u0930\u0940\u0915\u094d\u0937\u093e \u0915\u093e \u0928\u093e\u092e<\/th>\n                    <th>\u0918\u091f\u0915 \u0932\u0915\u094d\u0937\u094d\u092f<\/th>\n                    <th>\u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f<\/th>\n                <\/tr>\n                <tr>\n                    <td><strong>\u090f\u0915\u094d\u0938-\u0930\u0947 \u0926\u094b\u0937 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e<\/strong><\/td>\n                    <td>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930, \u0928\u0932\u093f\u092f\u093e\u0901<\/td>\n                    <td>\u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093c\u093f\u0928 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0939\u0935\u093e \u0915\u0947 \u0916\u093e\u0932\u0940 \u0938\u094d\u0925\u093e\u0928 \u092f\u093e \u0926\u0930\u093e\u0930\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u093e \u0938\u094d\u0915\u0948\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0938\u0939\u0928 \u0915\u094d\u0937\u092e\u0924\u093e<\/strong><\/td>\n                    <td>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u092a\u0941\u0930\u094d\u091c\u0947<\/td>\n                    <td>12kV \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0939\u0947\u0924\u0941 42kV\/1 \u092e\u093f\u0928\u091f \u0932\u093e\u0917\u0942 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0932\u0942\u092a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong><\/td>\n                    <td>\u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a<\/td>\n                    <td>\u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u0939\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0915\u092e \u0939\u094b\u0964.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0939\u0928\u0936\u0915\u094d\u0924\u093f<\/strong><\/td>\n                    <td>\u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a, \u091a\u0947\u0938\u093f\u0938<\/td>\n                    <td>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u0940 \u0906\u092f\u0941 \u0914\u0930 \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u091f\u093f\u0915\u093e\u090a\u092a\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0947 \u0932\u093f\u090f 2,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u091a\u0915\u094d\u0930\u0964.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0915\u093e\u0901\u091a \u0938\u0902\u0915\u094d\u0930\u092e\u0923 (Tg)<\/strong><\/td>\n                    <td>\u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0938\u093e\u092e\u0917\u094d\u0930\u0940<\/td>\n                    <td>\u0915\u094d\u092f\u094b\u0930 \u0915\u093f\u090f \u0917\u090f \u0930\u0947\u091c\u093c\u093f\u0928 \u092c\u0948\u091a \u0915\u0940 \u0924\u093e\u092a\u0940\u092f \u0938\u094d\u0925\u093f\u0930\u0924\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u092f\u094b\u0917\u0936\u093e\u0932\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u0964.<\/td>\n                <\/tr>\n            <\/table>\n            \n            <p>\n                \u0939\u092e\u093e\u0930\u0947 JN15 \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e \u092f\u0939 \u0938\u093e\u092c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0939\u0947\u0924\u0941 \u0936\u0949\u0930\u094d\u091f-\u091f\u093e\u0907\u092e \u0935\u093f\u0925\u0938\u094d\u091f\u0948\u0902\u0921 \u0915\u0930\u0902\u091f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u091f\u093e\u0907\u092a \u091f\u0947\u0938\u094d\u091f) \u092d\u0940 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0935\u0947 \u092c\u093f\u0928\u093e \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u092f\u093e \u0935\u093f\u0918\u091f\u0928 \u0915\u0947 31.5kA \u092f\u093e 40kA \u0915\u0940 \u0916\u0930\u093e\u092c\u0940 \u0915\u094b 4 \u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0906\u092a\u0915\u094b \u090f\u0915 \u0915\u0938\u094d\u091f\u092e \u0915\u0902\u092a\u094b\u0928\u0947\u0902\u091f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u092f\u094b\u0902 \u0915\u093e\u092e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f<\/h2>\n            <p>\n                \u092e\u093e\u0928\u0915 \u0918\u091f\u0915 \u0939\u0930 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0947\u0964 \u092a\u0948\u0928\u0932 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u094b \u0905\u0915\u094d\u0938\u0930 \u0930\u0947\u091f\u094d\u0930\u094b\u092b\u093f\u091f\u093f\u0902\u0917 \u091a\u0941\u0928\u094c\u0924\u093f\u092f\u094b\u0902 \u092f\u093e \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u0924\u093e \u0939\u0948\u0964 XBRELE \u091c\u0948\u0938\u0947 \u0915\u0938\u094d\u091f\u092e \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0906\u092a\u0915\u0947 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0938\u093e\u091d\u0947\u0926\u093e\u0930 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                \u0939\u092e \u0917\u0939\u0930\u0940 \u0905\u0928\u0941\u0915\u0942\u0932\u0928 \u0938\u0941\u0935\u093f\u0927\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u092a\u0941\u0930\u094d\u091c\u0947<\/strong>. \u092f\u0926\u093f \u0906\u092a\u0915\u0947 \u092c\u0938\u092c\u093e\u0930 \u0935\u093f\u0928\u094d\u092f\u093e\u0938 \u0915\u0947 \u0932\u093f\u090f \u0917\u0948\u0930-\u092e\u093e\u0928\u0915 \u092e\u094b\u0921\u093c \u0932\u094b\u0921 \u092f\u093e \u0924\u091f\u0940\u092f \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0915\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0926\u0942\u0930\u0940 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948, \u0924\u094b \u0939\u092e APG \u092e\u094b\u0932\u094d\u0921 \u0915\u094b \u0938\u0902\u0936\u094b\u0927\u093f\u0924 \u0915\u0930\u0915\u0947 \u0915\u0938\u094d\u091f\u092e \u092a\u094b\u0938\u094d\u091f \u0907\u0902\u0938\u0941\u0932\u0947\u091f\u0930 \u092f\u093e \u0935\u0949\u0932 \u092c\u0941\u0936\u093f\u0902\u0917 \u0924\u0948\u092f\u093e\u0930 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                \u0915\u0947 \u0932\u093f\u090f <strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u0941\u0930\u094d\u091c\u0947<\/strong>, \u0939\u092e VCB \u091a\u0947\u0938\u093f\u0938 \u091f\u094d\u0930\u0915 \u0915\u0940 \u091a\u094c\u0921\u093c\u093e\u0908 \u0914\u0930 \u0938\u094d\u091f\u094d\u0930\u094b\u0915 \u0915\u094b \u0917\u0948\u0930-\u092e\u093e\u0928\u0915 \u0915\u0948\u092c\u093f\u0928\u0947\u091f (\u091c\u0948\u0938\u0947 650 \u092e\u093f\u092e\u0940 \u0938\u0902\u0915\u0930\u0947 \u092a\u0948\u0928\u0932) \u092e\u0947\u0902 \u092b\u093f\u091f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u0915\u0942\u0932\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0932\u091a\u0940\u0932\u093e\u092a\u0928 OEMs \u0915\u094b \u092c\u0921\u093c\u0947 \u0938\u092e\u0942\u0939\u094b\u0902 \u0915\u0947 \u0915\u0920\u094b\u0930 \u0915\u0948\u091f\u0932\u0949\u0917 \u0938\u0947 \u092c\u0902\u0927\u0947 \u092c\u093f\u0928\u093e \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0921\u093f\u091c\u093e\u0907\u0928 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0905\u0928\u0941\u092d\u0935\u0940 \u0939\u0948\u0902\u0964<\/h2>\n            <p>\n                \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0947 \u0932\u093f\u090f \u092a\u0942\u0930\u0947 \u092a\u0948\u0928\u0932 \u0905\u0938\u0947\u0902\u092c\u0932 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u090f\u0915 \u0905\u0932\u0917 \u092e\u093e\u0928\u0938\u093f\u0915\u0924\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u092e\u0947\u0902 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0935\u093f\u091c\u094d\u091e\u093e\u0928 \u0914\u0930 \u092c\u0921\u093c\u0947 \u092a\u0948\u092e\u093e\u0928\u0947 \u092a\u0930 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u092e\u0947\u0902 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 XBRELE \u0907\u0938 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092e\u0947\u0902 \u0926\u0936\u0915\u094b\u0902 \u0915\u093e \u0905\u0928\u0941\u092d\u0935 \u0932\u093e\u0924\u093e \u0939\u0948\u0964 \u0939\u092e \u201c\u092a\u093e\u0902\u091a \u0930\u094b\u0915\u0925\u093e\u092e\u201d \u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0924\u0930\u094d\u0915 \u0915\u094b \u0917\u0939\u0930\u093e\u0908 \u0938\u0947 \u0938\u092e\u091d\u0924\u0947 \u0939\u0948\u0902 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0939\u092e \u0938\u094d\u0935\u092f\u0902 \u0924\u093e\u0932\u0947 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                \u0939\u092e\u093e\u0930\u093e \u0905\u0928\u0941\u092d\u0935 \u0905\u0902\u0924\u0930\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u092e\u093e\u0928\u0915\u094b\u0902 \u0924\u0915 \u092b\u0948\u0932\u093e \u0939\u0941\u0906 \u0939\u0948\u0964 \u0939\u092e \u091c\u093e\u0928\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0930\u0942\u0938 \u092e\u0947\u0902 \u0915\u093f\u0938\u0940 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0935\u0949\u0932 \u092c\u0941\u0936\u093f\u0902\u0917 (GOST \u092e\u093e\u0928\u0915) \u0926\u0915\u094d\u0937\u093f\u0923 \u092a\u0942\u0930\u094d\u0935 \u090f\u0936\u093f\u092f\u093e \u092e\u0947\u0902 \u092a\u094d\u0930\u092f\u0941\u0915\u094d\u0924 \u092c\u0941\u0936\u093f\u0902\u0917 (IEC \u092e\u093e\u0928\u0915) \u0938\u0947 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0905\u0928\u0941\u092d\u0935\u0940 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0907\u0928 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0905\u0902\u0924\u0930\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948 \u0915\u093f \u0906\u092a\u0915\u0947 \u0926\u094d\u0935\u093e\u0930\u093e \u0916\u0930\u0940\u0926\u0947 \u0917\u090f \u0918\u091f\u0915 \u0906\u092a\u0915\u0940 \u0938\u0902\u092a\u0942\u0930\u094d\u0923 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0915\u0947 \u0905\u0902\u0924\u093f\u092e \u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u0938\u092b\u0932 \u0939\u094b\u0902\u0917\u0947\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0932\u093e\u0917\u0924-\u0915\u0941\u0936\u0932 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u0938\u092e\u093e\u0927\u093e\u0928<\/h2>\n            <p>\n                \u091a\u0940\u0928 \u092e\u0947\u0902 \u090f\u0915 \u0935\u093f\u0936\u0947\u0937\u0940\u0915\u0943\u0924 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0938\u0947 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0932\u093e\u0917\u0924 \u0932\u093e\u092d \u092e\u093f\u0932\u0924\u093e \u0939\u0948\u0964 XBRELE \u0938\u0947 \u0938\u0940\u0927\u0947 \u0916\u0930\u0940\u0926\u0915\u0930 \u092a\u0948\u0928\u0932 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0935\u093f\u0924\u0930\u0915\u094b\u0902 \u0915\u0947 \u092e\u093e\u0930\u094d\u0915\u0905\u092a \u0915\u094b \u0926\u0930\u0915\u093f\u0928\u093e\u0930 \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0942\u090f\u0915\u093f\u0902\u0917 \u092e\u0947\u0902 \u0939\u092e\u093e\u0930\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0924\u093e\u0902\u092c\u0947 \u0914\u0930 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0915\u0947 \u0932\u093f\u090f \u0926\u0941\u0928\u093f\u092f\u093e \u0915\u0940 \u0938\u092c\u0938\u0947 \u0915\u0941\u0936\u0932 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u0924\u0915 \u092a\u0939\u0941\u0902\u091a \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.\n            <\/p>\n            <p>\n                \u0939\u092e \u092f\u0939 \u092d\u0940 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 <strong>\u0938\u0940\u0915\u0947\u0921\u0940 (\u092a\u0942\u0930\u094d\u0923 \u0928\u0949\u0915 \u0921\u093e\u0909\u0928)<\/strong> \u0914\u0930 <strong>\u090f\u0938\u0915\u0947\u0921\u0940<\/strong> \u0915\u093f\u091f\u0964 \u092d\u093e\u0930\u0940, \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0905\u0938\u0947\u0902\u092c\u0932 \u0915\u093f\u090f \u0917\u090f \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a \u092d\u0947\u091c\u0928\u0947 \u0915\u0947 \u092c\u091c\u093e\u092f, \u0939\u092e \u0918\u0928\u0940 \u092a\u0948\u0915\u0947\u091c\u093f\u0902\u0917 \u092e\u0947\u0902 \u092a\u0941\u0930\u094d\u091c\u0947 \u092d\u0947\u091c \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0906\u092a \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0938\u094d\u0924\u0930 \u092a\u0930 \u0905\u0938\u0947\u0902\u092c\u0932 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0938\u0947 \u0938\u092e\u0941\u0926\u094d\u0930\u0940 \u092e\u093e\u0932 \u0922\u0941\u0932\u093e\u0908 \u0932\u093e\u0917\u0924 \u0914\u0930 \u0906\u092f\u093e\u0924 \u0936\u0941\u0932\u094d\u0915 \u092e\u0947\u0902 \u092d\u093e\u0930\u0940 \u0915\u092e\u0940 \u0906\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u092a\u0915\u0947 \u0905\u0902\u0924\u093f\u092e \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0940 \u0915\u0940\u092e\u0924\u0947\u0902 \u0906\u092a\u0915\u0947 \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0928\u093f\u0935\u093f\u0926\u093e\u0913\u0902 \u092e\u0947\u0902 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u092a\u0930\u094d\u0927\u0940 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0902\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0905\u0928\u0941\u0915\u0942\u0932\u0928\u0940\u092f \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0915\u094d\u0937\u092e\u0924\u093e\u090f\u0901<\/h2>\n            <p>\n                XBRELE \u0905\u0938\u093e\u0927\u093e\u0930\u0923 \u0932\u091a\u0940\u0932\u093e\u092a\u0928 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0939\u092e \u092e\u0930\u092e\u094d\u092e\u0924 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e\u0913\u0902 (\u091c\u0948\u0938\u0947 5 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0949\u0915\u094d\u0938) \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u094d\u091a-\u092e\u093f\u0936\u094d\u0930\u0923, \u0915\u092e-\u092e\u093e\u0924\u094d\u0930\u093e \u0935\u093e\u0932\u0947 \u0911\u0930\u094d\u0921\u0930 \u0915\u094b \u0909\u0924\u0928\u0940 \u0939\u0940 \u0915\u0941\u0936\u0932\u0924\u093e \u0938\u0947 \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u091c\u093f\u0924\u0928\u0940 \u0915\u0941\u0936\u0932\u0924\u093e \u0938\u0947 \u0939\u092e \u0909\u091a\u094d\u091a-\u092e\u093e\u0924\u094d\u0930\u093e \u0935\u093e\u0932\u0947 OEM \u0911\u0930\u094d\u0921\u0930 (\u091c\u0948\u0938\u0947 \u090f\u0915 \u092b\u0948\u0915\u094d\u091f\u094d\u0930\u0940 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0930\u0928 \u0915\u0947 \u0932\u093f\u090f 5,000 \u092a\u094b\u0938\u094d\u091f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930) \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                \u0939\u092e\u093e\u0930\u0940 \u0909\u0924\u094d\u092a\u093e\u0926 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e KYN28 \u0914\u0930 XGN \u0915\u0948\u092c\u093f\u0928\u0947\u091f \u0915\u0947 \u092a\u0942\u0930\u0947 \u092a\u093e\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u0915\u0940 \u0924\u0902\u0924\u094d\u0930 \u0915\u094b \u0915\u0935\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u092a\u0948\u0928\u0932 \u0915\u0947 \u0928\u093f\u091a\u0932\u0947 \u0939\u093f\u0938\u094d\u0938\u0947 \u092e\u0947\u0902 \u0938\u094d\u0925\u093f\u0924 \u092d\u093e\u0930\u0940-\u092d\u0930\u0915\u092e \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a \u0938\u0947 \u0932\u0947\u0915\u0930 \u0928\u093f\u092e\u094d\u0928-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f \u092e\u0947\u0902 \u0932\u0917\u0947 \u091b\u094b\u091f\u0947 \u0939\u0940\u091f\u0930 \u0914\u0930 \u0928\u092e\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0915 \u0924\u0915, XBRELE \u090f\u0915 \u201c\u0935\u0928-\u0938\u094d\u091f\u0949\u092a \u0936\u0949\u092a\u201d \u0905\u0928\u0941\u092d\u0935 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0905\u0928\u0941\u0915\u0942\u0932\u0928\u0936\u0940\u0932\u0924\u093e \u0906\u092a\u0915\u0940 \u0916\u0930\u0940\u0926 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u094b \u0938\u0930\u0932 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948, \u0926\u0930\u094d\u091c\u0928\u094b\u0902 \u091b\u094b\u091f\u0947 \u0935\u093f\u0915\u094d\u0930\u0947\u0924\u093e\u0913\u0902 \u0915\u0947 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0915\u0947 \u092a\u094d\u0930\u0936\u093e\u0938\u0928\u093f\u0915 \u092c\u094b\u091d \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0938\u0924\u0924 \u0935\u093f\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092a\u094d\u0930\u0925\u093e\u090f\u0901<\/h2>\n            <p>\n                \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092e\u0947\u0902 \u0938\u094d\u0925\u093f\u0930\u0924\u093e \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0926\u0915\u094d\u0937\u0924\u093e \u0914\u0930 \u0905\u092a\u0936\u093f\u0937\u094d\u091f \u0915\u091f\u094c\u0924\u0940 \u092a\u0930 \u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0939\u0948\u0964 XBRELE \u0909\u0928\u094d\u0928\u0924 APG \u092e\u0936\u0940\u0928\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0928\u092e\u0947\u0902 \u090a\u0930\u094d\u091c\u093e \u0916\u092a\u0924 \u0915\u094b \u0915\u094d\u092f\u094b\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u092e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u0915\u0942\u0932\u093f\u0924 \u0939\u0940\u091f\u093f\u0902\u0917 \u091a\u0915\u094d\u0930 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n            <p>\n                \u0939\u092e \u0905\u092a\u0928\u0947 \u0927\u093e\u0924\u0941 \u0915\u0947 \u0915\u091a\u0930\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0916\u094d\u0924 \u0930\u0940\u0938\u093e\u0907\u0915\u094d\u0932\u093f\u0902\u0917 \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u092d\u0940 \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u092e\u093e\u0930\u0940 \u092e\u0936\u0940\u0928\u093f\u0902\u0917 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0938\u0947 \u0928\u093f\u0915\u0932\u0928\u0947 \u0935\u093e\u0932\u0947 \u0924\u093e\u0902\u092c\u0947 \u0915\u0947 \u0915\u091f\u093f\u0902\u0917 \u0905\u0935\u0936\u0947\u0937 \u090f\u0915\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0915\u0947 \u092a\u0941\u0928\u0930\u094d\u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u0915\u093f\u090f \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0940 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u092c\u0930\u094d\u092c\u093e\u0926\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0915\u0947 \u0905\u0932\u093e\u0935\u093e, \u0939\u092e\u093e\u0930\u0940 \u0938\u092d\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u093e\u0901 \u0914\u0930 \u092a\u094d\u0932\u0947\u091f\u093f\u0902\u0917 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901 RoHS \u0905\u0928\u0941\u0930\u0942\u092a \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0906\u092a\u0915\u093e \u0905\u0902\u0924\u093f\u092e \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u091a\u0940\u0928\u0940 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0947 \u0932\u093e\u092d<\/h2>\n            <p>\n                \u091a\u0940\u0928 \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0918\u091f\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u0936\u0915\u094d\u0924\u093f \u0915\u0947\u0902\u0926\u094d\u0930 \u0939\u0948\u0964 \u092f\u0939\u093e\u0902 \u0915\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0928\u0947 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0915\u0947 \u0910\u0938\u0947 \u092a\u0948\u092e\u093e\u0928\u0947 \u0915\u094b \u0939\u093e\u0938\u093f\u0932 \u0915\u093f\u092f\u093e \u0939\u0948 \u091c\u094b \u092c\u0947\u091c\u094b\u0921\u093c \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e-\u0938\u0947-\u092e\u0942\u0932\u094d\u092f \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964 XBRELE \u0907\u0938 \u092a\u093e\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u0915\u0940 \u0924\u0902\u0924\u094d\u0930 \u0915\u093e \u0932\u093e\u092d \u0909\u0920\u093e\u0915\u0930 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u0917\u0924\u093f:<\/strong> \u090f\u0915 \u0915\u0938\u094d\u091f\u092e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u0915\u0947 \u0932\u093f\u090f \u0928\u090f \u0938\u093e\u0901\u091a\u0947 \u0915\u093e \u0935\u093f\u0915\u093e\u0938 \u092e\u093e\u0924\u094d\u0930 15 \u0926\u093f\u0928\u094b\u0902 \u092e\u0947\u0902 \u092a\u0942\u0930\u093e \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/li>\n                <li><strong>\u0915\u094d\u0937\u092e\u0924\u093e:<\/strong> \u0939\u092e\u093e\u0930\u0940 \u092a\u094d\u0930\u0924\u093f\u0926\u093f\u0928 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u093e \u0909\u0924\u094d\u092a\u093e\u0926\u0928 2,000 \u0907\u0915\u093e\u0907\u092f\u094b\u0902 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0939\u092e \u0905\u091a\u093e\u0928\u0915 \u092c\u0922\u093c\u0940 \u092e\u093e\u0902\u0917 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n                <li><strong>\u090f\u0915\u0940\u0915\u0930\u0923:<\/strong> VCB \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u0947 \u0928\u093f\u0915\u091f \u0939\u094b\u0928\u0947 \u0915\u0947 \u0915\u093e\u0930\u0923, \u0939\u092e \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0939\u092e\u093e\u0930\u0947 \u0918\u091f\u0915 (\u091c\u0948\u0938\u0947 \u091a\u0947\u0938\u093f\u0938 \u0914\u0930 \u0938\u094d\u092a\u094c\u091f\u094d\u0938) VS1 \u0914\u0930 VD4 \u091c\u0948\u0938\u0947 \u0909\u0926\u094d\u092f\u094b\u0917-\u092e\u093e\u0928\u0915 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 \u092a\u0942\u0930\u094d\u0923 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0905\u0928\u0941\u0915\u0942\u0932\u0924\u093e \u0930\u0916\u0924\u0947 \u0939\u094b\u0902\u0964.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0938\u0939\u0940 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0916\u094b\u091c\u0928\u093e<\/h2>\n            <p>\n                \u0905\u092a\u0928\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0932\u093e\u0907\u0928 \u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u0935\u0936\u094d\u0930\u0947\u0937\u094d\u0920 \u0906\u092a\u0942\u0930\u094d\u0924\u093f\u0915\u0930\u094d\u0924\u093e \u091a\u0941\u0928\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u092a\u093e\u0930\u0926\u0930\u094d\u0936\u093f\u0924\u093e:<\/strong> \u0915\u094d\u092f\u093e \u0906\u092a\u0942\u0930\u094d\u0924\u093f\u0915\u0930\u094d\u0924\u093e \u0924\u093e\u0902\u092c\u0947 \u0915\u0940 \u0936\u0941\u0926\u094d\u0927\u0924\u093e \u0914\u0930 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0917\u094d\u0930\u0947\u0921 \u092c\u0924\u093e\u0924\u093e \u0939\u0948?<\/li>\n                <li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0941\u0935\u093f\u0927\u093e\u090f\u0901:<\/strong> \u0915\u094d\u092f\u093e \u0909\u0928\u0915\u0947 \u092a\u093e\u0938 \u0907\u0928-\u0939\u093e\u0909\u0938 \u090f\u0915\u094d\u0938-\u0930\u0947 \u0914\u0930 \u0939\u093e\u0908 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u092f\u094b\u0917\u0936\u093e\u0932\u093e\u090f\u0901 \u0939\u0948\u0902?<\/li>\n                <li><strong>\u0909\u0924\u094d\u092a\u093e\u0926 \u0915\u0940 \u0935\u094d\u092f\u093e\u092a\u0915\u0924\u093e:<\/strong> \u0915\u094d\u092f\u093e \u0935\u0947 \u092a\u0942\u0930\u0940 \u0915\u093f\u091f (\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 + \u0938\u0947\u0902\u0938\u0930 + \u0938\u094d\u0935\u093f\u091a) \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u092f\u093e \u0915\u0947\u0935\u0932 \u090f\u0915 \u092d\u093e\u0917?<\/li>\n                <li><strong>\u0928\u093f\u0930\u094d\u092f\u093e\u0924 \u0905\u0928\u0941\u092d\u0935:<\/strong> \u0915\u094d\u092f\u093e \u0935\u0947 \u092a\u0930\u093f\u0935\u0939\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u093e\u091c\u0941\u0915 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u0947 \u091f\u0942\u091f\u0928\u0947 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u092f\u093e\u0924 \u092a\u0948\u0915\u0947\u091c\u093f\u0902\u0917 \u0915\u094b \u0938\u092e\u091d\u0924\u0947 \u0939\u0948\u0902?<\/li>\n            <\/ul>\n            <p>\n                XBRELE \u0907\u0928 \u0938\u092d\u0940 \u092e\u093e\u0928\u0926\u0902\u0921\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0939\u092e \u0906\u092a\u0915\u0940 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u0915\u0947 \u0932\u093f\u090f \u0906\u0926\u0930\u094d\u0936 \u0930\u0923\u0928\u0940\u0924\u093f\u0915 \u092d\u093e\u0917\u0940\u0926\u093e\u0930 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-container\">\n        <div class=\"xbrele-cta-box\">\n            <h2>XBRELE \u0918\u091f\u0915\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u092c\u0947\u0939\u0924\u0930 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092c\u0928\u093e\u090f\u0901<\/h2>\n            <p>\u092b\u0948\u0915\u094d\u091f\u094d\u0930\u0940-\u0921\u093e\u092f\u0930\u0947\u0915\u094d\u091f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u092e\u0948\u0915\u0947\u0928\u093f\u0915\u0932 \u092a\u093e\u0930\u094d\u091f\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 \u0905\u092a\u0928\u0940 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u0915\u094b \u0938\u0941\u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n            <a href=\"https:\/\/xbrele.com\/hi\/contact\/\" class=\"xbrele-cta-btn\">\u090f\u0915 \u0918\u091f\u0915 \u0938\u0942\u091a\u0940 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0947\u0902<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Switchgear Component Manufacturer &#038; OEM Solutions Switchgear Component manufacturing is the foundational industry that powers the assembly of Medium Voltage (MV) and High Voltage (HV) electrical panels. It involves the precision engineering of critical &#8220;passive&#8221; parts\u2014such as epoxy insulation, earthing switches, and mechanical interlocks\u2014that ensure the safety and functionality of KYN28, XGN, and Ring Main [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1967","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"top","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1967","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=1967"}],"version-history":[{"count":3,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1967\/revisions"}],"predecessor-version":[{"id":1993,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/pages\/1967\/revisions\/1993"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=1967"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}