{"id":1537,"date":"2025-11-29T16:51:39","date_gmt":"2025-11-29T16:51:39","guid":{"rendered":"https:\/\/xbrele.com\/difference-between-vcb-and-contactor-in-electrical-systems\/"},"modified":"2026-04-07T15:12:19","modified_gmt":"2026-04-07T15:12:19","slug":"difference-between-vcb-and-contactor-in-electrical-systems","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/difference-between-vcb-and-contactor-in-electrical-systems\/","title":{"rendered":"\u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092e\u0947\u0902 \u0905\u0902\u0924\u0930"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e.webp\" alt=\"\u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092e\u0947\u0902 \u0905\u0902\u0924\u0930\" class=\"wp-image-1535\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u091b\u0935\u093f \u0938\u094d\u0930\u094b\u0924: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">\u092a\u0947\u0915\u094d\u0938\u0932\u094d\u0938<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u0915\u094d\u0938\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0915\u0941\u0936\u0932 \u0935\u093f\u0915\u0932\u094d\u092a \u091a\u0941\u0928\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930 \u0938\u092e\u091d\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (VCB) \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u0930\u094d\u0915 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u092c\u0941\u091d\u093e \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0939\u094b\u0924\u0940 \u0939\u0948 \u0914\u0930 \u092c\u093f\u091c\u0932\u0940 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0938\u094d\u0925\u093f\u0930 \u0930\u0939\u0924\u0940 \u0939\u0948\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092f\u0939 \u0926\u0948\u0928\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u0924\u093e \u0939\u0948\u0964 \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0928\u0947 \u0938\u0947 \u0906\u092a \u0938\u0902\u0938\u093e\u0927\u0928\u094b\u0902 \u0915\u0940 \u092c\u0930\u094d\u092c\u093e\u0926\u0940 \u0938\u0947 \u092c\u091a \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0932\u093e\u0917\u0924\u0947\u0902 \u0915\u092e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094b \u0906\u0938\u093e\u0928 \u092c\u0928\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0918\u093f\u0938\u093e\u0935 \u0915\u094b \u0915\u092e \u0915\u0930\u0915\u0947 \u0914\u0930 \u0909\u0928\u0915\u0940 \u0906\u092f\u0941 \u092c\u0922\u093c\u093e\u0915\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0915\u0941\u0936\u0932 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0907\u0928 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u092c\u093e\u091c\u093e\u0930 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u0940\u0915\u0930\u0923 \u0915\u0947 \u0915\u093e\u0930\u0923, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u090f\u0936\u093f\u092f\u093e-\u092a\u094d\u0930\u0936\u093e\u0902\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092e\u0947\u0902, \u092c\u0922\u093c \u0930\u0939\u093e \u0939\u0948\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u092e\u0941\u0916\u094d\u092f \u092c\u093e\u0924\u0947\u0902<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0915\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0913\u0935\u0930\u0932\u094b\u0921 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092c\u093e\u0930-\u092c\u093e\u0930 \u091a\u093e\u0932\u0942-\u092c\u0902\u0926 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u092d\u0935 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0914\u0930 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0926\u094b\u0937 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f VCB \u091a\u0941\u0928\u0947\u0902; \u0928\u093f\u092f\u092e\u093f\u0924 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u092e\u0947\u0902 \u0909\u091a\u094d\u091a \u0935\u093f\u0918\u091f\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u094b \u0909\u0928\u094d\u0939\u0947\u0902 \u092e\u0927\u094d\u092f\u092e \u0938\u0947 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0905\u0927\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u092c\u0915\u093f VCBs \u0915\u0947 \u0938\u0947\u0935\u093e \u0905\u0902\u0924\u0930\u093e\u0932 \u0932\u0902\u092c\u0947 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0905\u0902\u0924\u0930\u094b\u0902 \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u0906\u092a\u0915\u094b \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u092a\u0915\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0926\u0915\u094d\u0937\u0924\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0909\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u094b \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0938\u0947 \u092e\u093f\u0932\u093e\u090f\u0901\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0924\u094d\u092f\u0902\u0924 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948; VCBs \u0915\u0940 \u091c\u093e\u0901\u091a \u0939\u0930 1\u20133 \u0935\u0930\u094d\u0937 \u092e\u0947\u0902 \u0939\u094b\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u091c\u092c\u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0940 \u091c\u093e\u0901\u091a \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0915\u0930\u0928\u0940 \u092a\u0921\u093c\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"difference-between-vcb-and-contactor\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0935\u0940\u0938\u0940\u092f\u0942 \u0914\u0930 \u0935\u0940\u0938\u0940\u092c\u0940 - \u0905\u0902\u0924\u0930 : \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092f\u0942\u0928\u093f\u091f \u0914\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930\" width=\"1290\" height=\"968\" src=\"https:\/\/www.youtube.com\/embed\/mwd5eFAfCXA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-definition\">\u0935\u0940\u0938\u0940\u092c\u0940 \u092a\u0930\u093f\u092d\u093e\u0937\u093e<\/h3>\n\n\n\n<p>\u090f\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930, \u092f\u093e VCB, \u090f\u0915 \u0909\u092a\u0915\u0930\u0923 \u0939\u0948 \u091c\u093f\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0906\u092a \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u094b \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0913\u0935\u0930\u0932\u094b\u0921 \u092f\u093e \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u091a\u0932\u0924\u0947 \u0939\u0940 \u092c\u093f\u091c\u0932\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0930\u094b\u0915 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 VCB \u0938\u0930\u094d\u0915\u093f\u091f \u091f\u0942\u091f\u0928\u0947 \u092a\u0930 \u092c\u0928\u0928\u0947 \u0935\u093e\u0932\u0947 \u0906\u0930\u094d\u0915 \u0915\u094b \u092c\u0941\u091d\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0924\u0915\u0928\u0940\u0915 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u094d\u0925\u093f\u0930 \u092c\u093f\u091c\u0932\u0940 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"main-function\">\u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f<\/h4>\n\n\n\n<p>\u0906\u092a \u0916\u0924\u0930\u0928\u093e\u0915 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092c\u093f\u091c\u0932\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f VCB \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0915\u093e \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f \u0926\u094b\u0937 \u0915\u093e \u092a\u0924\u093e \u091a\u0932\u0924\u0947 \u0939\u0940 \u0924\u0941\u0930\u0902\u0924 \u0938\u0930\u094d\u0915\u093f\u091f \u0924\u094b\u0921\u093c\u0915\u0930 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u093e \u0939\u0948\u0964 \u092f\u0939 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0906\u0917 \u092f\u093e \u0905\u0928\u094d\u092f \u0916\u0924\u0930\u094b\u0902 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"protection-role\">\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092d\u0942\u092e\u093f\u0915\u093e<\/h4>\n\n\n\n<p>\u090f\u0915 VCB \u0906\u092a\u0915\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u0947 \u0932\u093f\u090f \u0922\u093e\u0932 \u0915\u093e \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0926\u094b\u0937\u092a\u0942\u0930\u094d\u0923 \u0939\u093f\u0938\u094d\u0938\u094b\u0902 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u092b\u0948\u0932\u093e\u0935 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u092e\u0927\u094d\u092f\u092e \u0938\u0947 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 1 kV \u0938\u0947 38 kV \u0924\u0915, \u0938\u0902\u092d\u093e\u0932\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f VCB \u092a\u0930 \u092d\u0930\u094b\u0938\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0907\u0938\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0924\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u093e \u090f\u0915 \u092a\u094d\u0930\u092e\u0941\u0916 \u0939\u093f\u0938\u094d\u0938\u093e \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"contactor-definition\">\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092a\u0930\u093f\u092d\u093e\u0937\u093e<\/h3>\n\n\n\n<p>\u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u090f\u0915 \u0909\u092a\u0915\u0930\u0923 \u0939\u0948 \u091c\u093f\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0906\u092a \u0938\u0930\u094d\u0915\u093f\u091f \u092e\u0947\u0902 \u092c\u093f\u091c\u0932\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091a\u0941\u092e\u094d\u092c\u0915 \u0915\u0940 \u0938\u0939\u093e\u092f\u0924\u093e \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0916\u094b\u0932\u0928\u0947 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0926\u094d\u0935\u093e\u0930\u093e \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u091c\u092c \u0906\u092a \u0915\u0949\u0907\u0932 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092c\u093f\u091c\u0932\u0940 \u0932\u094b\u0921, \u091c\u0948\u0938\u0947 \u092e\u094b\u091f\u0930 \u092f\u093e \u092a\u094d\u0930\u0915\u093e\u0936 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e, \u0924\u0915 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u091c\u092c \u0906\u092a \u0915\u0949\u0907\u0932 \u0915\u0940 \u090a\u0930\u094d\u091c\u093e \u092c\u0902\u0926 \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0916\u0941\u0932\u0928\u0947 \u092a\u0930 \u0927\u093e\u0930\u093e \u0930\u0941\u0915 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"main-function\">\u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f<\/h4>\n\n\n\n<p>\u0906\u092a \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915\u0932 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u094b \u091a\u093e\u0932\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0909\u092a\u0915\u0930\u0923 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0914\u0930 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u092a\u0930\u093f\u0935\u0947\u0936 \u092e\u0947\u0902 \u0906\u092e \u0939\u0948\u0964 \u092f\u0939 \u0906\u092a\u0915\u094b \u092c\u0921\u093c\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092d\u093e\u0930\u094b\u0902 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0915\u0941\u0936\u0932\u0924\u093e\u092a\u0942\u0930\u094d\u0935\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u091c\u092c \u0906\u092a\u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"actuator-role\">\u090f\u0915\u094d\u091a\u0941\u090f\u091f\u0930 \u0915\u0940 \u092d\u0942\u092e\u093f\u0915\u093e<\/h4>\n\n\n\n<p>\u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0906\u092a\u0915\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u092e\u0947\u0902 \u090f\u0915 \u0915\u094d\u0930\u093f\u092f\u093e\u0915\u093e\u0930\u0940 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0938\u0947 \u0906\u0928\u0947 \u0935\u093e\u0932\u0947 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u092e\u0936\u0940\u0928\u094b\u0902 \u092f\u093e \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0924\u0915 \u092c\u093f\u091c\u0932\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0915\u093e\u0930\u094d\u092f \u0906\u092a\u0915\u094b \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0938\u0940\u0927\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0947 \u092c\u091a\u093e\u0915\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"key-distinctions\">\u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0915\u0947 \u0932\u093f\u090f \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u0947 \u0905\u0902\u0924\u0930 \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u092f\u0939\u093e\u0901 \u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930 \u0926\u093f\u090f \u0917\u090f \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u090f\u0915 VCB \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u092c\u093e\u0927\u093f\u0924 \u0915\u0930\u0915\u0947 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f \u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092d\u093e\u0930\u094b\u0902 \u0915\u0947 \u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0926\u094b\u0928\u094b\u0902 \u0909\u092a\u0915\u0930\u0923 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0924\u0915\u0928\u0940\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0909\u0928\u0915\u093e \u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f \u0905\u0932\u0917-\u0905\u0932\u0917 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0926\u094b\u0937 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u092e\u0927\u094d\u092f\u092e \u0938\u0947 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0917\u0902\u092d\u0940\u0930 \u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u092e \u0938\u0947 \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u0938\u093e\u0925 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u094b \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0938\u0947 \u092e\u093f\u0932\u093e\u090f\u0901\u0964.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0928\u0940\u091a\u0947 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u0940 \u0917\u0908 \u0939\u0948 \u091c\u094b \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u092d\u0942\u092e\u093f\u0915\u093e\u0913\u0902 \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u094b\u0902 \u0915\u094b \u0909\u091c\u093e\u0917\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u092e \u092d\u0942\u092e\u093f\u0915\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0940\u092e\u093e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0926\u094b\u0937 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c (1 kV \u0938\u0947 38 kV)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u093e \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a \u092a\u093e\u0935\u0930 \u0935\u093f\u0924\u0930\u0923 \u0914\u0930 \u0926\u094b\u0937 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u0947\u0902 VCBs \u092a\u093e\u090f\u0902\u0917\u0947, \u091c\u092c\u0915\u093f \u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u092d\u0935\u0928 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0914\u0930 \u0935\u093f\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092e\u0947\u0902 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0906\u092e \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930 \u0909\u0928\u0915\u0940 \u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927\u0928 \u0924\u0915\u0928\u0940\u0915 \u092e\u0947\u0902 \u092d\u0940 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 VCB \u0936\u094d\u0930\u0947\u0937\u094d\u0920 \u0906\u0930\u094d\u0915 \u0936\u092e\u0928 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0909\u0928\u094d\u0939\u0947\u0902 \u0926\u094b\u0937 \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0926\u094b\u0937 \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0928\u0939\u0940\u0902 \u0915\u093f\u090f \u0917\u090f \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0938\u0930\u0932 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u0947 \u0938\u093e\u0925 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u092e\u0947\u0902 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0906\u092a \u0915\u092d\u0940-\u0915\u092d\u0940 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f VCBs \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0906\u092a \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0914\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092c\u093e\u0930-\u092c\u093e\u0930 \u091a\u093e\u0932\u0942-\u092c\u0902\u0926 \u091a\u0915\u094d\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u0947 \u0905\u0902\u0924\u0930 \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u0906\u092a\u0915\u094b \u0938\u0942\u091a\u093f\u0924 \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947, \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0947 \u0914\u0930 \u0905\u092a\u0928\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u091a\u0932\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"operation-and-performance\">\u0938\u0902\u091a\u093e\u0932\u0928 \u0914\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"switching-frequency\">\u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0943\u0924\u094d\u0924\u093f<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u0947 \u092c\u0940\u091a \u091a\u0941\u0928\u0947\u0902<\/a> \u0914\u0930 \u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u0964 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0906\u092a \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u092c\u093f\u0928\u093e \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0901\u091a\u093e\u090f \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0916\u094b\u0932 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0909\u0928 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, \u0906\u092a \u092a\u094d\u0930\u0924\u093f\u0926\u093f\u0928 \u0915\u0908 \u092c\u093e\u0930 \u092e\u094b\u091f\u0930\u094d\u0938 \u092f\u093e \u0932\u093e\u0907\u091f\u094d\u0938 \u0915\u094b \u091a\u093e\u0932\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092a\u094d\u0930\u0924\u093f \u0918\u0902\u091f\u0947 \u0939\u091c\u093e\u0930\u094b\u0902 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0909\u0928\u094d\u0939\u0947\u0902 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u0926\u0930\u094d\u0936 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0905\u0932\u0917 \u0924\u0930\u0939 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u092d\u0940-\u0915\u092d\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0926\u094b\u0937\u094b\u0902 \u092f\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928\u0964 \u0935\u0940\u0938\u0940\u092c\u0940 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0928\u0939\u0940\u0902 \u0938\u0915\u0924\u0947\u0964 \u092f\u0926\u093f \u0906\u092a \u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915 \u0936\u0940\u0918\u094d\u0930 \u0939\u0940 \u0918\u093f\u0938 \u091c\u093e\u090f\u0902\u0917\u0947\u0964 \u0906\u092a\u0915\u094b \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0947\u0935\u0932 \u0924\u092c \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u091c\u092c \u0906\u092a\u0915\u094b \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u092c\u093e\u0927\u093f\u0924 \u0915\u0930\u0928\u0947 \u092f\u093e \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u091a\u0941\u0928\u0947\u0902 \u0914\u0930 \u0926\u0941\u0930\u094d\u0932\u092d, \u0917\u0902\u092d\u0940\u0930 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u0940\u0938\u0940\u092c\u0940 \u091a\u0941\u0928\u0947\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"interrupting-capacity\">\u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u094d\u0937\u092e\u0924\u093e<\/h3>\n\n\n\n<p>\u0905\u0935\u0930\u094b\u0927 \u0915\u094d\u0937\u092e\u0924\u093e \u0906\u092a\u0915\u094b \u092c\u0924\u093e\u0924\u0940 \u0939\u0948 \u0915\u093f \u0915\u094b\u0908 \u0909\u092a\u0915\u0930\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0915\u093f\u0924\u0928\u0940 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u094b \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0907\u0938 \u092e\u093e\u0928 \u0915\u094b \u091c\u093e\u0928\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 VCB \u0915\u0940 \u0905\u0935\u0930\u094b\u0927 \u0915\u094d\u0937\u092e\u0924\u093e \u0905\u0927\u093f\u0915 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a \u0907\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092c\u0921\u093c\u0940 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0935\u093f\u0936\u0947\u0937\u0924\u093e VCB \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0924\u0930\u0923 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0940 \u0935\u093f\u0918\u091f\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u092c\u0939\u0941\u0924 \u0915\u092e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0918\u091f\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928\u0939\u0940\u0902 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a \u0910\u0938\u093e \u0915\u0930\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u093f\u092b\u0932 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0915\u094d\u0937\u0924\u093f \u092a\u0939\u0941\u0901\u091a\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092d\u093e\u0930 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0935\u093f\u0918\u091f\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u0939\u0940\u0902\u0964 \u092f\u0939 vcb \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u090f\u0915 \u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0906\u092a\u0915\u0940 \u0938\u0939\u093e\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u092f\u0939\u093e\u0901 \u090f\u0915 \u0938\u0930\u0932 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u0940 \u0917\u0908 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092f\u0902\u0924\u094d\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u094d\u0937\u092e\u0924\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u092e \u0909\u092a\u092f\u094b\u0917<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0940\u0938\u0940\u092c\u0940<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0941\u091f\u093f \u0930\u0941\u0915\u093e\u0935\u091f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 (\u0915\u094b\u0908 \u0926\u094b\u0937 \u0928\u0939\u0940\u0902)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"arc-interruption\">\u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u090f\u0915 \u0938\u0930\u094d\u0915\u093f\u091f \u0916\u094b\u0932\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u090f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u0930\u094d\u0915 \u092c\u0928\u0924\u093e \u0939\u0948\u0964 \u0915\u094d\u0937\u0924\u093f \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0907\u0938 \u0906\u0930\u094d\u0915 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u090f\u0915 VCB \u0906\u0930\u094d\u0915 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092c\u0941\u091d\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0939\u0935\u093e \u0915\u094b \u0939\u091f\u093e \u0926\u0947\u0924\u093e \u0939\u0948, \u0907\u0938\u0932\u093f\u090f \u0906\u0930\u094d\u0915 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u0928\u0939\u0940\u0902 \u091f\u093f\u0915 \u092a\u093e\u0924\u093e\u0964 \u0907\u0938\u0938\u0947 VCB \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0906\u0930\u094d\u0915 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092c\u0939\u0941\u0924 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092d\u0940 \u0906\u0930\u094d\u0915 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0924\u093e \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u092f\u0939 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u093e\u0964 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0906\u0930\u094d\u0915 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u0935\u093e \u092f\u093e \u0935\u093f\u0936\u0947\u0937 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0915\u092e \u0914\u0930 \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u0932\u093f\u090f \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f, \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0924\u0940\u0935\u094d\u0930 \u0906\u0930\u094d\u0915 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0928\u0939\u0940\u0902 \u0938\u0915\u0924\u0947\u0964 \u0917\u0902\u092d\u0940\u0930 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0906\u0930\u094d\u0915 \u0935\u093f\u0930\u093e\u092e \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u092f\u093e\u0926 \u0930\u0916\u0947\u0902: VCBs \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927\u0928 \u092e\u0947\u0902 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u092e \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0915\u0947 \u0938\u093e\u0925 \u0926\u0948\u0928\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"current-chop\">\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0915\u091f\u094c\u0924\u0940<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (VCB) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u201c\u0915\u0930\u0902\u091f \u091a\u0949\u092a\u201d \u0928\u093e\u092e\u0915 \u090f\u0915 \u0905\u0928\u0942\u0920\u0940 \u0918\u091f\u0928\u093e \u0926\u0947\u0916 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0930\u0902\u091f \u091a\u0949\u092a \u0924\u092c \u0939\u094b\u0924\u093e \u0939\u0948 \u091c\u092c \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u094d\u0930\u093e\u0915\u0943\u0924\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0936\u0942\u0928\u094d\u092f \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u0940 \u0927\u093e\u0930\u093e \u0915\u094b \u092c\u093e\u0927\u093f\u0924 \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u092a\u094d\u0930\u092d\u093e\u0935 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 VCBs \u092e\u0947\u0902 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0939\u0948\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u093e \u092d\u094c\u0924\u093f\u0915 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0909\u0928\u094d\u0939\u0947\u0902 \u092c\u0939\u0941\u0924 \u0939\u0940 \u091b\u094b\u091f\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092e\u0947\u0902 \u0927\u093e\u0930\u093e \u0915\u094b \u0924\u094b\u0921\u093c\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u0907\u0938\u0915\u093e \u092e\u0924\u0932\u092c \u0939\u0948 \u0915\u093f VCB \u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u093e \u0906\u0930\u094d\u0915 \u0905\u091a\u093e\u0928\u0915 \u0930\u0941\u0915 \u0938\u0915\u0924\u093e \u0939\u0948, \u092d\u0932\u0947 \u0939\u0940 \u0927\u093e\u0930\u093e \u0905\u092a\u0928\u0947 \u092a\u094d\u0930\u093e\u0915\u0943\u0924\u093f\u0915 \u0905\u0902\u0924 \u0924\u0915 \u0928 \u092a\u0939\u0941\u0901\u091a\u0940 \u0939\u094b\u0964.<\/p>\n\n\n\n<p>\u091c\u092c \u0906\u092a VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0907\u0938\u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u093e \u0906\u0930\u094d\u0915 \u0915\u0949\u0932\u092e \u0905\u0938\u094d\u0925\u093f\u0930 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092d\u093e\u092a \u0926\u092c\u093e\u0935 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u092c\u093f\u091c\u0932\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u0947 \u0924\u0930\u0940\u0915\u0947 \u091c\u0948\u0938\u0947 \u0915\u093e\u0930\u0915 \u0906\u0930\u094d\u0915 \u0915\u094b \u0938\u092e\u092f \u0938\u0947 \u092a\u0939\u0932\u0947 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0930\u0941\u0915\u093e\u0935\u091f \u0909\u091a\u094d\u091a \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u0947 \u0915\u094d\u0937\u0923\u093f\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0905\u0927\u093f\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u092f\u0947 \u0905\u091a\u093e\u0928\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u0930 \u0924\u0928\u093e\u0935 \u0921\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 \u092f\u0939 \u092a\u094d\u0930\u092d\u093e\u0935 \u0909\u0924\u0928\u093e \u0928\u0939\u0940\u0902 \u0926\u0947\u0916\u0924\u0947\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0927\u093e\u0930\u093e \u0915\u094b \u0909\u0938\u0940 \u0924\u0930\u0939 \u092c\u093e\u0927\u093f\u0924 \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u0947, \u0907\u0938\u0932\u093f\u090f \u0935\u0947 \u0936\u093e\u092f\u0926 \u0939\u0940 \u0915\u092d\u0940 \u0927\u093e\u0930\u093e \u092e\u0947\u0902 \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u092f\u093e \u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0905\u0927\u093f\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u094d\u0930\u0940-\u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915 \u0914\u0930 \u0915\u0930\u0902\u091f \u091a\u0949\u092a\u093f\u0902\u0917 \u091c\u0948\u0938\u0940 \u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0935\u093e\u0932\u0947 \u0927\u093e\u0930\u093e \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u092d\u0940 \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0909\u0928\u0915\u0940 \u0935\u093f\u0936\u0947\u0937 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0917\u0941\u0923\u0927\u0930\u094d\u092e \u0907\u0938\u0947 \u0938\u0902\u092d\u0935 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092f\u0939 \u091c\u093e\u0928\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0915\u093f \u092f\u0947 \u0935\u094d\u092f\u0935\u0939\u093e\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u092e\u0947\u0902 \u092d\u093f\u0928\u094d\u0928\u0924\u093e \u0932\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u092f\u093e \u0932\u0902\u092c\u0940 \u0915\u0947\u092c\u0932 \u0932\u093e\u0907\u0928\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u0930\u0902\u091f \u091a\u0949\u092a \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0913\u0935\u0930\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0928\u094b\u091f:<\/strong> \u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u092e\u0947\u0902 \u092c\u093f\u091c\u0932\u0940 \u0915\u0940 \u0924\u0930\u0902\u0917\u094b\u0902 \u092e\u0947\u0902 \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u090f\u0915 \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u0923 \u0939\u0948 \u0915\u093f \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930 \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0917\u0932\u0924 \u0938\u094d\u0925\u093e\u0928 \u092a\u0930 VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915\u094d\u0938 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u094d\u0935\u0930\u093f\u0924 \u0924\u0941\u0932\u0928\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0936\u0947\u0937\u0924\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0940\u0938\u0940\u092c\u0940 (\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915\u0915<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0915\u091f\u094c\u0924\u0940<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092e\u093e\u0928\u094d\u092f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0941\u0930\u094d\u0932\u092d<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0927\u093f-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u094b\u0916\u093f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a\u0924\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u092e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u091a\u093e\u0928\u0915, \u0915\u093f\u0938\u0940 \u092d\u0940 \u0938\u092e\u092f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u093e\u0915\u0943\u0924\u093f\u0915 \u0936\u0942\u0928\u094d\u092f \u092a\u0930<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-voltage\">\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/h3>\n\n\n\n<p>\u0906\u092a \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 VCBs \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u0947 \u0905\u0902\u0926\u0930 \u092e\u094c\u091c\u0942\u0926 \u0915\u0949\u0907\u0932 \u092f\u093e \u090f\u0915\u094d\u091f\u094d\u092f\u0942\u090f\u091f\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u091c\u092c \u0906\u092a \u0938\u0939\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0921\u093f\u0935\u093e\u0907\u0938 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u2014\u092f\u093e \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0916\u094b\u0932\u0924\u093e \u0939\u0948 \u092f\u093e \u092c\u0902\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>VCBs \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0909\u091a\u094d\u091a \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0915\u093e \u0915\u093e\u0930\u0923 \u092f\u0939 \u0939\u0948 \u0915\u093f \u0907\u0938\u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u0940 \u0915\u094d\u0930\u093f\u092f\u093e\u0935\u093f\u0927\u093f \u0915\u094b \u092c\u0921\u093c\u0947, \u092d\u093e\u0930\u0940 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u091a\u0932\u093e\u0928\u093e \u0914\u0930 \u0909\u091a\u094d\u091a \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u092d\u093e\u0932\u0928\u0940 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a \u0905\u0915\u094d\u0938\u0930 \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 110V DC, 220V DC \u092f\u093e \u0909\u0938\u0938\u0947 \u092d\u0940 \u0905\u0927\u093f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0926\u0947\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0928\u093f\u092e\u094d\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0905\u092a\u0928\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 24V, 48V, \u092f\u093e 110V AC \u092f\u093e DC \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0938\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u094b \u0911\u091f\u094b\u092e\u0947\u0936\u0928 \u092a\u0948\u0928\u0932 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u092e\u0947\u0902 \u090f\u0915\u0940\u0915\u0943\u0924 \u0915\u0930\u0928\u093e \u0906\u0938\u093e\u0928 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0907\u0928\u094d\u0939\u0947\u0902 \u092e\u093e\u0928\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0930\u093f\u0932\u0947 \u092f\u093e \u092a\u094d\u0930\u094b\u0917\u094d\u0930\u093e\u092e\u0947\u092c\u0932 \u0932\u0949\u091c\u093f\u0915 \u0915\u0902\u091f\u094d\u0930\u094b\u0932\u0930 (PLC) \u0915\u0947 \u0938\u093e\u0925 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0947 \u092a\u0939\u0932\u0947 \u0906\u0935\u0936\u094d\u092f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0939\u092e\u0947\u0936\u093e \u091c\u093e\u0902\u091a\u0947\u0902\u0964 \u0917\u0932\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 \u092f\u093e \u0920\u0940\u0915 \u0938\u0947 \u0915\u093e\u092e \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u093e\u0964.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u0928\u093f\u092e\u094d\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0927\u093f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0915\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u0907\u0928\u094d\u0939\u0947\u0902 \u092a\u094d\u0930\u092c\u0902\u0927\u093f\u0924 \u0915\u0930\u0928\u093e \u0906\u0938\u093e\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964  \u092d\u093e\u0930\u0940-\u092d\u0930\u0915\u092e \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 VCBs \u092e\u0947\u0902, \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u094d\u091a \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-and-endurance\">\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0927\u0948\u0930\u094d\u092f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"overcurrent-protection\">\u0905\u0927\u093f-\u0927\u093e\u0930\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0927\u093e\u0930\u093e \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0927\u093e\u0930\u093e \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0901\u091a\u093e \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0906\u0917 \u0932\u0917 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964  \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940) \u0906\u092a\u0915\u094b \u092e\u091c\u092c\u0942\u0924 \u0905\u0924\u093f\u0927\u093e\u0930\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964  \u092f\u0939 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0932\u094b\u0921 \u0927\u093e\u0930\u093e\u0913\u0902 \u0914\u0930 \u0916\u0924\u0930\u0928\u093e\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e\u0913\u0902 \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u093e \u0939\u0948\u0964  \u0906\u092a \u092d\u0930\u094b\u0938\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u091c\u092c \u0927\u093e\u0930\u093e \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u0939\u094b \u091c\u093e\u090f\u0917\u0940 \u0924\u094b \u0935\u0940\u0938\u0940\u092c\u0940 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0930\u094b\u0915 \u0926\u0947\u0917\u093e\u0964.<\/p>\n\n\n\n<p>A <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0902\u092a\u0930\u094d\u0915\u093f\u0924\u094d\u0930<\/a> \u092f\u0939 \u0905\u0932\u0917 \u0924\u0930\u0939 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0932\u094b\u0921 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u092f\u0939 \u0938\u094d\u0935\u092f\u0902 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u093e\u0964 \u091c\u092c \u0906\u092a \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0926\u0947\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u092b\u094d\u092f\u0942\u091c \u092f\u093e \u0930\u093f\u0932\u0947 \u091c\u0948\u0938\u0947 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0909\u092a\u0915\u0930\u0923 \u091c\u094b\u0921\u093c\u0928\u0947 \u0939\u094b\u0902\u0917\u0947\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0939\u0948 \u091c\u094b \u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930 \u0926\u093f\u0916\u093e\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0936\u0947\u0937\u0924\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 (\u0935\u0940\u0938\u0940)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0927\u093f-\u0927\u093e\u0930\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901, \u0932\u094b\u0921 \u0914\u0930 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e\u0913\u0902 \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0940\u092e\u093f\u0924, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0941\u091f\u093f \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u0928 \u0915\u094d\u0937\u092e\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0941\u091f\u093f \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0909\u091a\u094d\u091a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928, \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0928\u0939\u0940\u0902 \u0915\u093f\u092f\u093e \u0917\u092f\u093e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0927\u093f\u092d\u093e\u0930, \u0932\u0918\u0941-\u092a\u0930\u093f\u092a\u0925, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0905\u0902\u0924\u0930-\u0924\u093e\u0932\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0947\u0935\u0932 \u0932\u094b\u0921 \u0927\u093e\u0930\u093e \u0935\u093f\u0918\u091f\u0928 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0913\u0935\u0930\u0932\u094b\u0921 \u0914\u0930 \u092b\u0949\u0932\u094d\u091f \u0938\u0947 \u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u093e\u0939\u093f\u090f \u0924\u094b VCB \u091a\u0941\u0928\u0947\u0902\u0964 \u0938\u0930\u0932 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902, \u0932\u0947\u0915\u093f\u0928 \u0939\u092e\u0947\u0936\u093e \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091c\u094b\u0921\u093c\u0947\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"short-circuit-capability\">\u0938\u0902\u0915\u094d\u0937\u093f\u092a\u094d\u0924-\u092a\u0930\u093f\u092a\u0925 \u0915\u094d\u0937\u092e\u0924\u093e<\/h3>\n\n\n\n<p>\u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0927\u093e\u0930\u093e\u090f\u0901 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0910\u0938\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948 \u091c\u094b \u0907\u0928 \u0916\u0924\u0930\u0928\u093e\u0915 \u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0947\u0964 VCB \u0907\u0938 \u0915\u093e\u092e \u0915\u0947 \u0932\u093f\u090f \u092c\u0928\u093e\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964 \u092f\u0939 \u092c\u0939\u0941\u0924 \u0909\u091a\u094d\u091a \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0918\u091f\u0928\u093e \u0915\u0947 \u092c\u093e\u0926 \u092d\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964 \u0906\u092a VCBs \u092a\u0930 Icu (\u0905\u0932\u094d\u091f\u093f\u092e\u0947\u091f \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0930\u0902\u091f) \u0914\u0930 Ics (\u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0930\u0902\u091f) \u091c\u0948\u0938\u0940 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0926\u0947\u0916\u0947\u0902\u0917\u0947\u0964 \u092f\u0947 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0906\u092a\u0915\u094b \u092c\u0924\u093e\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u093f\u0928\u093e \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0915\u093f\u0924\u0928\u0940 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u092a\u093e\u0938 \u092f\u0947 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0902\u0964 \u0935\u0947 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0928\u0939\u0940\u0902 \u0924\u094b\u0921\u093c \u0938\u0915\u0924\u0947\u0964 \u0935\u0947 \u0915\u0947\u0935\u0932 \u0925\u094b\u0921\u093c\u0947 \u0938\u092e\u092f \u0915\u0947 \u0932\u093f\u090f \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u0915\u094b \u0935\u0939\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0907\u0938\u0947 \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u0947\u0964 \u0926\u094b\u0937 \u0915\u094b \u0924\u094b\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b VCB \u092f\u093e \u092b\u094d\u092f\u0942\u091c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u0941\u0932\u0928\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0936\u0947\u0937\u0924\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915\u0915 (\u090f\u0932\u092c\u0940\u090f\u0938)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0938\u0940\u092f\u0942 (\u0905\u0932\u094d\u091f\u0940\u092e\u0947\u091f \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0930\u0902\u091f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0942 \u0928\u0939\u0940\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0938\u0940\u090f\u0938 (\u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0930\u0902\u091f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0942 \u0928\u0939\u0940\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0938\u0940\u090f\u092e (\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u094d\u0937\u092e\u0924\u093e)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0942 \u0928\u0939\u0940\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0938\u0940\u0921\u092c\u094d\u0932\u094d\u092f\u0942 (\u0905\u0932\u094d\u092a\u0915\u093e\u0932\u093f\u0915 \u0938\u0939\u0928 \u0927\u093e\u0930\u093e)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0942 \u0928\u0939\u0940\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u092a\u0940\u0915\u0947 (\u092a\u0940\u0915 \u0935\u093f\u0925\u0938\u094d\u091f\u0948\u0902\u0921 \u0915\u0930\u0902\u091f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0942 \u0928\u0939\u0940\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0928\u094b\u091f:<\/strong> \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0915\u0947\u0935\u0932 \u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u094b \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0928\u0939\u0940\u0902 \u0930\u0916 \u0938\u0915\u0924\u093e\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mechanical-endurance\">\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0939\u0928\u0936\u0915\u094d\u0924\u093f<\/h3>\n\n\n\n<p>\u0906\u092a \u091a\u093e\u0939\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0906\u092a\u0915\u093e \u0909\u092a\u0915\u0930\u0923 \u0932\u0902\u092c\u0947 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0947\u0964 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0925\u093e\u092f\u093f\u0924\u094d\u0935 \u0906\u092a\u0915\u094b \u092c\u0924\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u0906\u092a \u0915\u093f\u0938\u0940 \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0907\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u093f \u0935\u0939 \u0918\u093f\u0938 \u091c\u093e\u090f\u0964 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0935\u093f\u0924\u0930\u0923-\u0936\u094d\u0930\u0947\u0923\u0940 \u0915\u0947 VCB 10,000 \u0938\u0947 20,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0941\u091b \u0935\u093f\u0936\u0947\u0937 VCB 100,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u092f\u093e \u0909\u0938\u0938\u0947 \u0905\u0927\u093f\u0915 \u0924\u0915 \u091a\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0915\u093e \u092e\u0924\u0932\u092c \u0939\u0948 \u0915\u093f \u092f\u0926\u093f \u0906\u092a \u0907\u0938\u0947 \u0938\u0939\u0940 \u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u094b \u0906\u092a \u0915\u0908 \u0935\u0930\u094d\u0937\u094b\u0902 \u0924\u0915 \u090f\u0915 VCB \u092a\u0930 \u092d\u0930\u094b\u0938\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092e\u0947\u0902 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0914\u0930 \u092d\u0940 \u0905\u0927\u093f\u0915 \u091f\u093f\u0915\u093e\u090a\u092a\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0907\u0928\u094d\u0939\u0947\u0902 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u092c\u0928\u093e\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 \u092f\u0947 \u0938\u0948\u0915\u0921\u093c\u094b\u0902 \u0939\u091c\u093e\u0930\u094b\u0902 \u092f\u093e \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u0932\u093e\u0916\u094b\u0902 \u092c\u093e\u0930 \u0915\u093e\u092e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0909\u0928\u094d\u0939\u0947\u0902 \u0909\u0928 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u0926\u0930\u094d\u0936 \u092c\u0928\u093e\u0924\u093e \u0939\u0948 \u091c\u0939\u093e\u0901 \u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u093f\u0926\u093f\u0928 \u0915\u0908 \u092c\u093e\u0930 \u0909\u092a\u0915\u0930\u0923 \u091a\u093e\u0932\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940: 10,000 \u0938\u0947 20,000 \u0938\u0902\u091a\u093e\u0932\u0928 (\u092e\u093e\u0928\u0915), 100,000 \u0924\u0915 (\u0935\u093f\u0936\u0947\u0937 \u092a\u094d\u0930\u0915\u093e\u0930)<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938: \u0905\u0915\u094d\u0938\u0930 \u0932\u093e\u0916\u094b\u0902 \u0938\u0947 \u0915\u0930\u094b\u0921\u093c\u094b\u0902 \u0938\u0902\u091a\u093e\u0932\u0928<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0930\u0928\u0940 \u0939\u094b, \u0924\u094b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u091a\u0941\u0928\u0947\u0902\u0964 \u0915\u092d\u0940-\u0915\u092d\u093e\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f, VCB \u0906\u092a\u0915\u094b \u0932\u0902\u092c\u0940 \u0906\u092f\u0941 \u0914\u0930 \u092e\u091c\u092c\u0942\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"maintenance-needs\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (VCB) \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u091a\u092f\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u0938\u094b\u091a\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u0905\u091a\u094d\u091b\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0906\u092a\u0915\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948\u0964  \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0909\u092a\u0915\u0930\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0905\u0932\u0917 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902, \u0907\u0938\u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u093e \u0938\u092e\u092f-\u0938\u093e\u0930\u093f\u0923\u0940 \u0914\u0930 \u0938\u0902\u0938\u093e\u0927\u0928 \u092f\u094b\u091c\u0928\u093e\u092c\u0926\u094d\u0927 \u0930\u0942\u092a \u0938\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 VCB \u0915\u093e \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u092e\u091c\u092c\u0942\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0907\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0907\u0938\u0947 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964 VCB \u0915\u0947 \u0905\u0902\u0926\u0930 \u092e\u094c\u091c\u0942\u0926 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u091c\u0932\u094d\u0926\u0940 \u0916\u0930\u093e\u092c \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u093e\u0964 \u0906\u092a \u0932\u0902\u092c\u0947 \u0938\u0930\u094d\u0935\u093f\u0938 \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u0940 \u0909\u092e\u094d\u092e\u0940\u0926 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0915\u092d\u0940-\u0915\u092d\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0915\u0908 \u0938\u093e\u0932 \u0924\u0915\u0964 \u0906\u092a\u0915\u094b \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092d\u093e\u0917\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0939\u0930 1 \u0938\u0947 3 \u0938\u093e\u0932 \u092e\u0947\u0902 \u090f\u0915 \u092c\u093e\u0930 \u092a\u0942\u0930\u094d\u0923 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0938\u0932\u093e\u0939 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0920\u094b\u0930 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0907\u0938\u0947 \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u092a\u0921\u093c \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0905\u0932\u0917 \u0924\u0930\u0939 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0907\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0907\u0938\u0932\u093f\u090f \u092f\u0939 \u0905\u0927\u093f\u0915 \u0918\u093f\u0938\u093e\u0935 \u0914\u0930 \u091f\u0942\u091f-\u092b\u0942\u091f \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0915\u0908 \u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092c\u093e\u0926 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u092f\u093e \u0909\u0928 \u092a\u0930 \u0917\u0921\u094d\u0922\u0947 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0935\u094d\u092f\u0938\u094d\u0924 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0939\u0930 \u0915\u0941\u091b \u092e\u0939\u0940\u0928\u094b\u0902 \u092e\u0947\u0902 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0928\u0947 \u092f\u093e \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0915\u0949\u0907\u0932 \u0914\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0925\u0915\u093e\u0928 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092d\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0909\u092a\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u092c\u0928\u093e\u090f\u0902\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u0914\u0930 \u092e\u0939\u0902\u0917\u0940 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0938\u0947 \u092c\u091a\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0906\u092a\u0915\u0940 \u0938\u0939\u093e\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u0940 \u0917\u0908 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0915\u093e\u0930\u094d\u092f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u092a\u0947\u0915\u094d\u0937\u093f\u0924 \u0906\u092f\u0941<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 (1-3 \u0935\u0930\u094d\u0937)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902, \u0938\u092b\u093c\u093e\u0908 \u0915\u0930\u0947\u0902, \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902, \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10-20 \u0935\u0930\u094d\u0937 \u092f\u093e \u0909\u0938\u0938\u0947 \u0905\u0927\u093f\u0915<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a (3-12 \u092e\u0939\u0940\u0928\u0947)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923, \u0938\u092b\u093e\u0908 \u0914\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0930\u0947\u0902\u0964<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>5-10 \u0935\u0930\u094d\u0937<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0926\u094b\u0928\u094b\u0902 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u092a\u0947\u092f\u0930 \u092a\u093e\u0930\u094d\u091f\u094d\u0938 \u0939\u093e\u0925 \u092e\u0947\u0902 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 VCBs \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092f\u093e \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u094d\u0938 \u0914\u0930 \u0915\u0949\u0907\u0932\u094d\u0938 \u0915\u093e \u0938\u094d\u091f\u0949\u0915 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a \u092a\u0939\u0932\u0947 \u0938\u0947 \u0924\u0948\u092f\u093e\u0930\u0940 \u0915\u0930 \u0932\u0947\u0902 \u0924\u094b \u0906\u092a \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0915\u092e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092e\u0949\u0921\u0932 \u0915\u0940 \u0935\u093f\u0936\u0947\u0937 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092e\u0948\u0928\u0941\u0905\u0932 \u092a\u0922\u093c\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0914\u0930 \u0905\u092a\u0928\u0947 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u091a\u094d\u091b\u0947 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u0938\u0947\u0935\u093e \u0924\u093f\u0925\u093f\u092f\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u094b \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092e\u0947\u0902 \u091c\u0932\u0928\u0947 \u092f\u093e \u0917\u0921\u094d\u0922\u0947\u0926\u093e\u0930 \u0939\u094b\u0928\u0947 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0906\u0935\u0930\u0923 \u0938\u0947 \u0927\u0942\u0932 \u0914\u0930 \u092e\u0932\u092c\u0947 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u094b\u0907\u0932 \u0914\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0928\u0941\u0938\u093e\u0930 \u091a\u0932\u0924\u0940 \u092d\u093e\u0917\u094b\u0902 \u092e\u0947\u0902 \u091a\u093f\u0915\u0928\u093e\u0908 \u0932\u0917\u093e\u090f\u0901\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0905\u0928\u0926\u0947\u0916\u0940 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0909\u092a\u0915\u0930\u0923 \u0915\u0940 \u0916\u0930\u093e\u092c\u0940 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091c\u094b\u0916\u093f\u092e\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u092a\u0921\u093c \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u0926\u0947\u0916\u092d\u093e\u0932 \u0938\u0947 \u0906\u092a \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u092a\u0948\u0938\u0947 \u092c\u091a\u093e\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u094b \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u091a\u0932\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0928\u094b\u091f:<\/strong> \u0906\u092a\u0915\u094b \u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0936\u091f\u0921\u093e\u0909\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0930\u0916\u0930\u0916\u093e\u0935 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938\u0938\u0947 \u0906\u092a\u0915\u093e \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0939\u0924\u093e \u0939\u0948 \u0914\u0930 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n<\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u091c\u0930\u0942\u0930\u0924\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0905\u0927\u093f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0905\u092a\u0928\u0947 \u0928\u093f\u0935\u0947\u0936 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u0941\u091a\u093e\u0930\u0942 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"applications-and-use-cases\">\u0906\u0935\u0947\u0926\u0928 \u0914\u0930 \u0909\u092a\u092f\u094b\u0917 \u0915\u0947 \u092e\u093e\u092e\u0932\u0947<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57.webp\" alt=\"\u0906\u0935\u0947\u0926\u0928 \u0914\u0930 \u0909\u092a\u092f\u094b\u0917 \u0915\u0947 \u092e\u093e\u092e\u0932\u0947\" class=\"wp-image-1536\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u091b\u0935\u093f \u0938\u094d\u0930\u094b\u0924: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/unsplash.com\">\u0905\u0928\u0938\u094d\u092a\u094d\u0932\u0948\u0936<\/a><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-applications\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"power-distribution\">\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0924\u0930\u0923<\/h4>\n\n\n\n<p>\u0906\u092a \u0905\u0915\u094d\u0938\u0930 \u092a\u093e\u0935\u0930 \u0935\u093f\u0924\u0930\u0923 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0926\u0947\u0916\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0936\u0939\u0930\u0940 \u0914\u0930 \u0917\u094d\u0930\u093e\u092e\u0940\u0923 \u0926\u094b\u0928\u094b\u0902 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092b\u0940\u0921\u0930\u094d\u0938, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094d\u0938 \u0914\u0930 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a VCBs \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u093e\u0915\u093f \u092c\u093f\u091c\u0932\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b\u0924\u0940 \u0930\u0939\u0947 \u0914\u0930 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u094b \u0930\u094b\u0915\u093e \u091c\u093e \u0938\u0915\u0947\u0964 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0938\u0902\u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902, \u0906\u092a \u092e\u094b\u091f\u0930\u094d\u0938, \u092d\u091f\u094d\u091f\u093f\u092f\u094b\u0902 \u0914\u0930 \u0905\u0928\u094d\u092f \u092d\u093e\u0930\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f VCBs \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u092c\u094d\u0930\u0947\u0915\u0930 \u0930\u0947\u0932\u0935\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u0940\u0915\u0930\u0923 \u092e\u0947\u0902 \u092d\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u0942\u092e\u093f\u0915\u093e \u0928\u093f\u092d\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u0939\u093e\u0901 \u092f\u0947 \u091f\u094d\u0930\u0948\u0915\u094d\u0936\u0928 \u092a\u093e\u0935\u0930 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0939\u0948 \u091c\u094b VCBs \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u092a\u0930\u093f\u0926\u0943\u0936\u094d\u092f\u094b\u0902 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u092a\u0930\u093f\u0926\u0943\u0936\u094d\u092f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0924\u0930\u0923 \u0928\u0947\u091f\u0935\u0930\u094d\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0924\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092b\u0940\u0921\u0930\u094b\u0902, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0914\u0930 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0938\u0902\u092f\u0902\u0924\u094d\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u0916\u093e\u0928\u094b\u0902 \u092e\u0947\u0902 \u092e\u094b\u091f\u0930\u094d\u0938, \u092d\u091f\u094d\u091f\u093f\u092f\u094b\u0902 \u0914\u0930 \u092d\u093e\u0930\u0940 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0947\u0932 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u0940\u0915\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u0948\u0915\u094d\u0936\u0928 \u092a\u093e\u0935\u0930 \u0938\u093f\u0938\u094d\u091f\u092e\u094b\u0902 \u0915\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0935\u0928 \u090a\u0930\u094d\u091c\u093e \u0909\u0924\u094d\u092a\u093e\u0926\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0935\u0928 \u091f\u0930\u092c\u093e\u0907\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u0928\u0928 \u0938\u0902\u091a\u093e\u0932\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u091a\u0941\u0928\u094c\u0924\u0940\u092a\u0942\u0930\u094d\u0923 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902 \u0932\u093e\u0907\u0928, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0914\u0930 \u092c\u0938\u092c\u093e\u0930 \u0938\u0902\u0930\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0906\u092a\u0915\u094b \u0915\u0920\u094b\u0930 \u0914\u0930 \u0909\u091a\u094d\u091a-\u092e\u093e\u0902\u0917 \u0935\u093e\u0932\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"high-voltage-systems\">\u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/h4>\n\n\n\n<p>\u0906\u092a \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 VCBs \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0907\u0938\u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0935\u0947 \u092c\u0921\u093c\u0947 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0936\u0940\u0918\u094d\u0930\u0924\u093e \u0938\u0947 \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092a\u0935\u0928 \u090a\u0930\u094d\u091c\u093e \u0909\u0924\u094d\u092a\u093e\u0926\u0928, \u0916\u0928\u0928 \u0938\u0902\u091a\u093e\u0932\u0928 \u0914\u0930 \u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0909\u092a\u0938\u094d\u091f\u0947\u0936\u0928 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964 \u092a\u0935\u0928 \u092b\u093e\u0930\u094d\u092e\u094b\u0902 \u092e\u0947\u0902, VCBs \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u0930\u094d\u092c\u093e\u0907\u0928\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0916\u0928\u0928 \u092e\u0947\u0902, \u0906\u092a \u0915\u0920\u093f\u0928 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f VCBs \u092a\u0930 \u092d\u0930\u094b\u0938\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0909\u092a\u0938\u094d\u091f\u0947\u0936\u0928 \u0932\u093e\u0907\u0928\u094b\u0902, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0914\u0930 \u092c\u0938\u092c\u093e\u0930\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f VCBs \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"contactor-applications\">\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"motor-control\">\u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923<\/h4>\n\n\n\n<p>\u0906\u092a \u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0938\u092c\u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0906\u092a\u0915\u094b \u0935\u093f\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u092e\u0947\u0902 \u092e\u094b\u091f\u0930\u094d\u0938 \u0915\u094b \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0936\u0941\u0930\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 HVAC \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902, \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0902\u092a\u094d\u0930\u0947\u0938\u0930, \u092c\u094d\u0932\u094b\u0905\u0930 \u092e\u094b\u091f\u0930\u094d\u0938 \u0914\u0930 \u092a\u0902\u0916\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0907\u0928\u094d\u0939\u0947\u0902 \u092a\u0902\u092a\u094b\u0902, \u0915\u0928\u094d\u0935\u0947\u092f\u0930 \u092c\u0947\u0932\u094d\u091f\u094b\u0902 \u0914\u0930 \u092e\u093f\u0915\u094d\u0938\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092d\u0940 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u094b \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0914\u0930 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u0930\u094d\u0924\u093e \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0909\u092a\u092f\u094b\u0917 \u0915\u0947 \u092e\u093e\u092e\u0932\u094b\u0902 \u0915\u0940 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u0940 \u0917\u0908 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0947\u0926\u0928 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0909\u092a\u092f\u094b\u0917 \u0915\u0947 \u092e\u093e\u092e\u0932\u0947<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092e\u0947\u0902 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\/\u0938\u094d\u091f\u0949\u092a<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u090f\u091a\u0935\u0940\u090f\u0938\u0940 \u0938\u093f\u0938\u094d\u091f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0902\u092a\u094d\u0930\u0947\u0938\u0930, \u092c\u094d\u0932\u094b\u0905\u0930 \u092e\u094b\u091f\u0930 \u0914\u0930 \u092a\u0902\u0916\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u093e\u092a\u0928 \u0909\u092a\u0915\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0913\u0935\u0928 \u0914\u0930 \u092c\u0949\u092f\u0932\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092c\u093f\u091c\u0932\u0940<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u092a\u094d\u0930\u0915\u093e\u0936 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u0915\u093e\u0936 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u093e \u0938\u092e\u0928\u094d\u0935\u093f\u0924 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0902\u092a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091c\u0932 \u092a\u0930\u093f\u0938\u0902\u091a\u0930\u0923 \u0914\u0930 \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0916\u0941\u0930\u093e\u0915<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0902\u092a\u094d\u0930\u0947\u0938\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0940\u0924\u0932\u0940\u0915\u0930\u0923 \u0914\u0930 \u0935\u093e\u092f\u0941 \u0938\u0902\u092a\u0940\u0921\u093c\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0928\u094d\u0935\u0947\u092f\u0930 \u092c\u0947\u0932\u094d\u091f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0948\u0915\u0947\u091c\u093f\u0902\u0917 \u0914\u0930 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0932\u093e\u0907\u0928\u094b\u0902 \u092e\u0947\u0902 \u0917\u0924\u093f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093f\u0915\u094d\u0938\u0930 \u0914\u0930 \u0939\u0932\u091a\u0932 \u092f\u0902\u0924\u094d\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u093e\u0926\u094d\u092f \u092a\u094d\u0930\u0938\u0902\u0938\u094d\u0915\u0930\u0923 \u0914\u0930 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u092e\u093f\u0936\u094d\u0930\u0923<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0906\u092a \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0940 \u092e\u0926\u0926 \u0938\u0947 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"frequent-switching\">\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917<\/h4>\n\n\n\n<p>\u091c\u092c \u0906\u092a\u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u0924\u092c \u0906\u092a \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u091a\u0941\u0928\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924, \u0926\u094b\u0939\u0930\u093e\u090f \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902, \u091c\u0948\u0938\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u092a\u094d\u0930\u0915\u093e\u0936 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092f\u093e \u0915\u0928\u094d\u0935\u0947\u092f\u0930 \u092c\u0947\u0932\u094d\u091f \u091a\u0932\u093e\u0928\u093e\u0964 \u0906\u092a \u0905\u0927\u093f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u091c\u094b\u0921\u093c\u0915\u0930 \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u093e \u0906\u0938\u093e\u0928\u0940 \u0938\u0947 \u0935\u093f\u0938\u094d\u0924\u093e\u0930 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0932\u091a\u0940\u0932\u093e\u092a\u0928 \u0938\u094d\u0915\u0947\u0932\u0947\u092c\u0932 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u0905\u092a \u0914\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092e\u094b\u091f\u0930\u094d\u0938 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>HVAC \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0902\u092a\u094d\u0930\u0947\u0938\u0930\u094d\u0938 \u0914\u0930 \u092a\u0902\u0916\u094b\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0915\u0947 \u0924\u093e\u092a\u092e\u093e\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0932\u093e\u0907\u091f\u093f\u0902\u0917 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092c\u0921\u093c\u0947 \u092a\u094d\u0930\u0915\u093e\u0936 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"selection-criteria\">\u091a\u092f\u0928 \u092e\u093e\u0928\u0926\u0902\u0921<\/h3>\n\n\n\n<p>VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092e\u0947\u0902 \u091a\u092f\u0928 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948, \u0924\u094b \u0906\u092a\u0915\u094b VCB \u091a\u0941\u0928\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0914\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948, \u0924\u094b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0947\u0939\u0924\u0930 \u0935\u093f\u0915\u0932\u094d\u092a \u0939\u0948\u0964 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930, \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902\u0964 \u091c\u092c \u0906\u092a \u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u094b \u0905\u092a\u0928\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u091a\u0941\u0928\u0924\u0947 \u0939\u0948\u0902, \u0924\u092c VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930 \u0938\u094d\u092a\u0937\u094d\u091f \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0938\u0941\u091d\u093e\u0935: \u0905\u0902\u0924\u093f\u092e \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0915\u0930\u0902\u091f \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0902\u092c\u0902\u0927\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"technical-comparison-table\">\u0924\u0915\u0928\u0940\u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0924\u093e\u0932\u093f\u0915\u093e<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-vs-contactor-summary\">\u0935\u0940\u0938\u0940\u092c\u0940 \u092c\u0928\u093e\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u093e\u0930\u093e\u0902\u0936<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (VCB) \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u091a\u092f\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u090f\u0915 \u0938\u094d\u092a\u0937\u094d\u091f \u0924\u0941\u0932\u0928\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u0906\u092a\u0915\u094b \u0938\u092c\u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u0913\u0902 \u0915\u0940 \u0938\u093e\u0907\u0921-\u092c\u093e\u092f-\u0938\u093e\u0907\u0921 \u091d\u0932\u0915 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0938\u0947 \u0906\u092a \u0926\u0947\u0916 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0909\u092a\u0915\u0930\u0923 \u0915\u0948\u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u092e\u0947\u0902 \u0915\u094d\u092f\u093e \u0909\u092e\u094d\u092e\u0940\u0926 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0936\u0947\u0937\u0924\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915\u0915<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u094b\u0937 \u0938\u0902\u0930\u0915\u094d\u0937\u0923 \u0914\u0930 \u092a\u0930\u093f\u092a\u0925 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0914\u0930 \u0932\u094b\u0921 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u094d\u0937\u092e\u0924\u093e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a (\u092c\u0921\u093c\u0947 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u093e \u0939\u0948)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 (\u0924\u094d\u0930\u0941\u091f\u093f \u0930\u0941\u0915\u093e\u0935\u091f \u0915\u0947 \u0932\u093f\u090f \u0928\u0939\u0940\u0902)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0906\u0930\u094d\u0915 \u092a\u094d\u0930\u092c\u0902\u0927\u0928<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0906\u0930\u094d\u0915\u093f\u0902\u0917, \u0932\u0902\u092c\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0906\u092f\u0941<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0927\u093f\u0915 \u0906\u0930\u094d\u0915\u093f\u0902\u0917, \u092c\u093e\u0930-\u092c\u093e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0915\u091f\u094c\u0924\u0940<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092e\u093e\u0928\u094d\u092f, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915\u094d\u0938 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0941\u0930\u094d\u0932\u092d, \u0905\u0924\u093f\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u0915\u092e \u091c\u094b\u0916\u093f\u092e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917, \u0924\u0947\u091c\u093c \u0906\u0930\u094d\u0915 \u0936\u092e\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u0935\u093e \u092f\u093e \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917, \u0927\u0940\u092e\u0940 \u0906\u0930\u094d\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0940\u092e\u093e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0927\u094d\u092f\u092e \u0938\u0947 \u0909\u091a\u094d\u091a (1 kV \u0938\u0947 38 kV)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 \u0938\u0947 \u092e\u0927\u094d\u092f\u092e (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 1.1 \u0915\u093f\u0932\u094b\u0935\u094b\u0932\u094d\u091f \u0924\u0915)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0935\u0943\u0924\u094d\u0924\u093f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 (\u0915\u092d\u0940-\u0915\u092d\u0940 \u0938\u0902\u091a\u093e\u0932\u0928)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a (\u092a\u094d\u0930\u0924\u093f \u0918\u0902\u091f\u0947 \u0939\u091c\u093e\u0930\u094b\u0902 \u091a\u0915\u094d\u0930)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0915\u093e\u0930\u094d\u092f\u092a\u094d\u0930\u0923\u093e\u0932\u0940<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u092e \u092c\u0932, \u0938\u0930\u0932 \u092f\u0902\u0924\u094d\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u090a\u0930\u094d\u091c\u093e-\u0916\u092a\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u0949\u0907\u0932<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0905\u0927\u093f-\u0927\u093e\u0930\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901, \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093f\u0924<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u0939\u0940\u0902, \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0938\u0902\u0915\u094d\u0937\u093f\u092a\u094d\u0924-\u092a\u0930\u093f\u092a\u0925 \u0915\u094d\u0937\u092e\u0924\u093e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0901, \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u094d\u0938 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f\u094d\u0938<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u0939\u0940\u0902, \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0928\u0939\u0940\u0902 \u0924\u094b\u0921\u093c\u093e \u091c\u093e \u0938\u0915\u0924\u093e\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0939\u0928\u0936\u0915\u094d\u0924\u093f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10,000\u2013100,000 \u0911\u092a\u0930\u0947\u0936\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100,000\u20131,000,000+ \u0911\u092a\u0930\u0947\u0936\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u0902\u092c\u0947, \u0927\u0940\u092e\u0947 \u0905\u0902\u0924\u0930\u093e\u0932<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a, \u092c\u093e\u0930-\u092c\u093e\u0930 \u091c\u093e\u0902\u091a\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0938\u094d\u0925\u093e\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u0915\u094d\u0937\u093f\u092a\u094d\u0924, \u092a\u0948\u0928\u0932 \u0938\u094d\u0925\u093e\u0928 \u092c\u091a\u093e\u0924\u093e \u0939\u0948<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092c\u0921\u093c\u093e \u092a\u0926\u091a\u093f\u0939\u094d\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0926\u0942\u0937\u093f\u0924 \u0939\u094b\u0928\u0947 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u090a\u0901\u091a\u093e, \u0915\u094b\u0908 \u0906\u0930\u094d\u0915 \u091a\u094d\u092f\u0942\u091f\u094d\u0938 \u0915\u0940 \u091c\u093c\u0930\u0942\u0930\u0924 \u0928\u0939\u0940\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u0940\u091a\u0947, \u0938\u092b\u093e\u0908 \u0915\u0940 \u091c\u0930\u0942\u0930\u0924 \u0939\u0948<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a (110V\u2013220V DC\/AC)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 (24V\u2013110V AC\/DC)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0909\u092a\u092f\u094b\u0917<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0924\u0930\u0923, \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0938\u094d\u0935\u091a\u093e\u0932\u0928, \u092a\u094d\u0930\u0915\u093e\u0936 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0906\u092a \u0905\u092a\u0928\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0938 \u0924\u093e\u0932\u093f\u0915\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0947\u0902\u091c \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"bullet-point-highlights\">\u092e\u0941\u0916\u094d\u092f \u092c\u093f\u0902\u0926\u0941<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u091c\u092c \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0926\u094b\u0937\u094b\u0902 \u0914\u0930 \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e\u0913\u0902 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u0924\u092c \u0906\u092a VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0906\u092a \u092e\u094b\u091f\u0930\u094d\u0938 \u092f\u093e \u0932\u093e\u0907\u091f\u094d\u0938 \u0915\u0947 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0914\u0930 \u0906\u0938\u093e\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u091a\u0941\u0928\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0906\u0930\u094d\u0915 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u0915\u094d\u0937\u0924\u093f \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0908 \u0911\u0928-\u0911\u092b \u091a\u0915\u094d\u0930\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0907\u0928\u094d\u0939\u0947\u0902 \u0905\u0927\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 (VCBs) \u0915\u0930\u0902\u091f \u092e\u0947\u0902 \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915 \u092a\u0948\u0926\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0907\u0938\u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 \u0913\u0935\u0930\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u091c\u094b\u0916\u093f\u092e\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0936\u093e\u092f\u0926 \u0939\u0940 \u0915\u092d\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915\u094d\u0938 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0911\u091f\u094b\u092e\u0947\u0936\u0928 \u092a\u0948\u0928\u0932 \u092e\u0947\u0902 \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0905\u0927\u093f\u0915 \u0938\u094d\u0925\u093e\u0928 \u092c\u091a\u093e\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0927\u0942\u0932 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923 \u0915\u093e \u092c\u0947\u0939\u0924\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u092f\u0926\u093f \u0906\u092a \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 \u091c\u094b\u0921\u093c\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u092e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0938\u093e\u0925 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0906\u092a\u0915\u094b \u0909\u0928\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0947\u0935\u0932 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0939\u0940 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0906\u092a\u0915\u094b \u0909\u091a\u094d\u091a \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0925\u093e\u092f\u093f\u0924\u094d\u0935 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0938\u093f\u0938\u094d\u091f\u092e\u094b\u0902 \u092e\u0947\u0902 \u0938\u092c\u0938\u0947 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u092f\u0926\u093f \u0906\u092a \u092e\u091c\u092c\u0942\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0915\u092e \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u093e\u0939\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b VCB \u091a\u0941\u0928\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0924\u0947\u091c\u093c, \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948, \u0924\u094b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0906\u092a\u0915\u093e \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0935\u093f\u0915\u0932\u094d\u092a \u0939\u0948\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"choosing-the-right-device\">\u0938\u0939\u0940 \u0921\u093f\u0935\u093e\u0907\u0938 \u091a\u0941\u0928\u0928\u093e<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"decision-factors\">\u0928\u093f\u0930\u094d\u0923\u092f \u0915\u093e\u0930\u0915<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (VCB) \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u091a\u092f\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u0908 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0915\u093e\u0930\u0915\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0905\u092a\u0928\u0940 \u0905\u0928\u0942\u0920\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902, \u0907\u0938\u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0909\u092a\u0915\u0930\u0923 \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939\u093e\u0901 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0928\u0947 \u092f\u094b\u0917\u094d\u092f \u0938\u092c\u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092c\u093f\u0902\u0926\u0941 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e<\/strong>\u0906\u092a \u090f\u0915 \u0910\u0938\u093e \u0909\u092a\u0915\u0930\u0923 \u091a\u093e\u0939\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u0939\u0930 \u092c\u093e\u0930 \u0915\u093e\u092e \u0915\u0930\u0947\u0964 VCBs \u0905\u092a\u0928\u0947 \u092e\u091c\u092c\u0942\u0924 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0914\u0930 \u0915\u092e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u091c\u093c\u0930\u0942\u0930\u0924\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0909\u091a\u094d\u091a \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092c\u0939\u0941\u0924 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948 \u091c\u0939\u093e\u0901 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u091f\u094c\u0924\u0940 \u092c\u0921\u093c\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u092a\u0948\u0926\u093e \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923-\u092e\u093f\u0924\u094d\u0930\u0924\u093e<\/strong>VCBs \u0917\u0948\u0938\u094b\u0902 \u092f\u093e \u0924\u0947\u0932\u094b\u0902 \u0915\u0947 \u092c\u091c\u093e\u092f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0909\u0928\u094d\u0939\u0947\u0902 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0906\u092a\u0915\u0940 \u091a\u093f\u0902\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u092c\u0947\u0939\u0924\u0930 \u0935\u093f\u0915\u0932\u094d\u092a \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0939\u093e\u0928\u093f\u0915\u093e\u0930\u0915 \u0917\u094d\u0930\u0940\u0928\u0939\u093e\u0909\u0938 \u0917\u0948\u0938\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092c\u091a\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901<\/strong>VCBs \u0915\u0908 \u0905\u0928\u094d\u092f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0906\u0930\u094d\u0915 \u0915\u094b \u092c\u0947\u0939\u0924\u0930 \u0924\u0930\u0940\u0915\u0947 \u0938\u0947 \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 \u0935\u0947 \u0906\u0930\u094d\u0915 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092c\u0941\u091d\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0906\u092a\u0915\u093e \u0909\u092a\u0915\u0930\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/strong>\u0906\u092a\u0915\u094b \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0921\u093f\u0935\u093e\u0907\u0938 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0932\u094b\u0921 \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u0915\u094d\u0937\u092e\u0924\u093e \u0915\u093e \u0909\u0932\u094d\u0932\u0902\u0918\u0928<\/strong>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0909\u092a\u0915\u0930\u0923 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0909\u091a\u094d\u091a\u0924\u092e \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092c\u093e\u0927\u093f\u0924 \u0915\u0930 \u0938\u0915\u0947\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u091f\u093f\u0915\u093e\u090a\u092a\u0928 \u0914\u0930 \u0909\u092a\u092f\u094b\u0917 \u092e\u0947\u0902 \u0906\u0938\u093e\u0928\u0940<\/strong>\u0910\u0938\u093e \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0947\u0902 \u091c\u094b \u0932\u0902\u092c\u0947 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0947 \u0914\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0906\u0938\u093e\u0928 \u0939\u094b\u0964 \u0907\u0938\u0938\u0947 \u0906\u092a\u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0916\u0930\u094d\u091a \u0914\u0930 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u092e\u0947\u0902 \u0915\u092e\u0940 \u0906\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u0938\u094d\u092e\u093e\u0930\u094d\u091f \u0938\u0941\u0935\u093f\u0927\u093e\u090f\u0901<\/strong>\u0915\u0941\u091b \u0921\u093f\u0935\u093e\u0907\u0938 \u0911\u091f\u094b\u092e\u0947\u0936\u0928 \u092f\u093e IoT \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0947 \u091c\u0941\u0921\u093c \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a \u0930\u093f\u092e\u094b\u091f \u0915\u0902\u091f\u094d\u0930\u094b\u0932 \u092f\u093e \u092e\u0949\u0928\u093f\u091f\u0930\u093f\u0902\u0917 \u091a\u093e\u0939\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0907\u0928 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u0915\u0940 \u0924\u0932\u093e\u0936 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0935\u093e\u0924\u093e\u0935\u0930\u0923<\/strong>: \u0938\u094b\u091a\u0947\u0902 \u0915\u093f \u0906\u092a \u0921\u093f\u0935\u093e\u0907\u0938 \u0915\u0939\u093e\u0901 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0917\u0947\u0964 \u0927\u0942\u0932, \u0928\u092e\u0940 \u0914\u0930 \u0938\u094d\u0925\u093e\u0928 \u0906\u092a\u0915\u0947 \u091a\u092f\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p><strong>\u092c\u094d\u0930\u093e\u0902\u0921 \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e<\/strong>\u0938\u0940\u092e\u0947\u0902\u0938, \u0908\u091f\u0928, \u0936\u094d\u0928\u093e\u0907\u0921\u0930 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0914\u0930 \u0935\u0940\u0936\u094b \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u091c\u0948\u0938\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u094d\u0930\u093e\u0902\u0921 \u0905\u0915\u094d\u0938\u0930 \u092c\u0947\u0939\u0924\u0930 \u0938\u092e\u0930\u094d\u0925\u0928 \u0914\u0930 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0905\u0902\u0924\u093f\u092e \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0914\u0930 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902\u0964 \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0915\u0941\u0936\u0932 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"practical-recommendations\">\u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u0947\u0902<\/h3>\n\n\n\n<p>\u0906\u092a \u0905\u092a\u0928\u0940 \u0907\u092e\u093e\u0930\u0924 \u092f\u093e \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0938\u092c\u0938\u0947 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0928\u0947 \u092e\u0947\u0902 \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e \u0938\u0932\u093e\u0939 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u093f\u0916\u093e\u0924\u0940 \u0939\u0948 \u0915\u093f \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0935\u093e\u0924\u093e\u0935\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0915\u093f\u0938 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u093e \u092c\u094d\u0930\u0947\u0915\u0930 \u0938\u092c\u0938\u0947 \u0905\u091a\u094d\u091b\u093e \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u0930\u094d\u0935\u0936\u094d\u0930\u0947\u0937\u094d\u0920 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091a\u0941\u0928\u093e\u0935 \u0915\u093e \u0915\u093e\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0927\u0942\u0932 \u092d\u0930\u093e\/\u0917\u0902\u0926\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0940\u0932\u092c\u0902\u0926 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0927\u0942\u0932 \u0914\u0930 \u0915\u0923\u094b\u0902 \u0915\u094b \u092c\u093e\u0939\u0930 \u0930\u0916\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0930\u094d\u0926\u094d\u0930\/\u0915\u094d\u0937\u0930\u0923\u0915\u093e\u0930\u0940<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u094b\u0908 \u0924\u0947\u0932 \u092f\u093e \u0917\u0948\u0938 \u0928\u0939\u0940\u0902, \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u092e\u091c\u092c\u0942\u0924 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0940\u092e\u093f\u0924 \u0938\u094d\u0925\u093e\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u090f\u0938\u090f\u092b6 \u092f\u093e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u0906\u0915\u093e\u0930, \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0906\u0938\u093e\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0917 \u092f\u093e \u0935\u093f\u0938\u094d\u092b\u094b\u091f \u0915\u093e \u0915\u094b\u0908 \u0916\u0924\u0930\u093e \u0928\u0939\u0940\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u091a\u092f\u0928 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0906\u092a\u0915\u094b \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092d\u0940 \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u094d\u0937\u092e\u0924\u093e \u0926\u0947\u0916\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0938\u094b\u091a\u093f\u090f \u0915\u093f \u0906\u092a\u0915\u094b \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u094b \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u0924\u093e \u0939\u0948\u0964 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902, \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0924\u0925\u093e \u0926\u0941\u0930\u094d\u0932\u092d \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0915\u093e \u0927\u094d\u092f\u093e\u0928 \u0930\u0916\u0947\u0902\u0964 \u0915\u0920\u094b\u0930 \u092f\u093e \u0917\u0902\u0926\u0947 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u092e\u0947\u0902 VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0905\u091a\u094d\u091b\u0940 \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e \u0914\u0930 \u092e\u091c\u092c\u0942\u0924 \u0938\u092e\u0930\u094d\u0925\u0928 \u0935\u093e\u0932\u093e \u090f\u0915 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0947\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0938\u094d\u092e\u093e\u0930\u094d\u091f \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948, \u0924\u094b \u0910\u0938\u093e \u092e\u0949\u0921\u0932 \u091a\u0941\u0928\u0947\u0902 \u091c\u094b \u0906\u092a\u0915\u0947 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0938\u093e\u0925 \u0915\u093e\u092e \u0915\u0930\u0947\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\ud83d\udee0\ufe0f <strong>\u0928\u094b\u091f:<\/strong> \u0938\u0939\u0940 \u0935\u093f\u0915\u0932\u094d\u092a \u0906\u092a\u0915\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0932\u0915\u094d\u0937\u094d\u092f\u094b\u0902 \u0914\u0930 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0935\u093f\u0915\u0932\u094d\u092a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0938\u092e\u092f \u0932\u0947\u0902 \u0914\u0930 \u092f\u0926\u093f \u0906\u092a\u0915\u0947 \u0915\u094b\u0908 \u092a\u094d\u0930\u0936\u094d\u0928 \u0939\u094b\u0902 \u0924\u094b \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e\u094b\u0902 \u0938\u0947 \u092a\u0942\u091b\u0947\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0906\u092a\u0928\u0947 \u0938\u0940\u0916\u093e \u0939\u0948 \u0915\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (VCBs) \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0906\u092a\u0915\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 VCBs \u0916\u0924\u0930\u0928\u093e\u0915 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0906\u0917 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0906\u092a\u0915\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0914\u0930 \u0932\u0902\u092c\u0940 \u0938\u0947\u0935\u093e \u0905\u0935\u0927\u093f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u091a\u0941\u0928\u0928\u0947 \u0938\u0947 \u0906\u092a\u0915\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0915\u0941\u0936\u0932 \u092c\u0928\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u0940\u0938\u0940\u092c\u0940 \u092b\u0949\u0932\u094d\u091f\u094d\u0938 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0916\u0924\u0930\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n\n\n\n<li><p>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u092c\u0947\u0939\u0924\u0930\u0940\u0928 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902 \u092f\u093e \u0905\u0902\u0924\u093f\u092e \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u093f\u0938\u0940 \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e \u0938\u0947 \u092a\u0930\u093e\u092e\u0930\u094d\u0936 \u0915\u0930\u0947\u0902\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-main-difference-between-a-vcb-and-a-contactor\">VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092e\u0947\u0902 \u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930 \u0915\u094d\u092f\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u0906\u092a \u092e\u0927\u094d\u092f\u092e \u0938\u0947 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0926\u094b\u0937 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f VCB \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092d\u093e\u0930\u094b\u0902 \u0915\u0947 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 VCB \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092d\u093e\u0930\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-use-a-contactor-instead-of-a-vcb\">\u0915\u094d\u092f\u093e \u0906\u092a VCB \u0915\u0947 \u092c\u091c\u093e\u092f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b VCB \u0915\u0947 \u0938\u094d\u0925\u093e\u0928 \u092a\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928\u0939\u0940\u0902 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u0947\u0964 \u0915\u0947\u0935\u0932 VCB \u0939\u0940 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u092f\u093e \u0913\u0935\u0930\u0932\u094b\u0921 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"where-do-you-install-vcbs-and-contactors\">\u0906\u092a VCBs \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0939\u093e\u0901 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0906\u092a \u092a\u093e\u0935\u0930 \u0935\u093f\u0924\u0930\u0923 \u092a\u0948\u0928\u0932\u094b\u0902, \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u0914\u0930 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 VCBs \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u0902\u0926\u094d\u0930\u094b\u0902, \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u092a\u0948\u0928\u0932\u094b\u0902 \u0914\u0930 \u092a\u094d\u0930\u0915\u093e\u0936 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u092e\u0947\u0902 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-often-do-you-need-to-maintain-a-vcb-or-contactor\">\u0906\u092a\u0915\u094b \u090f\u0915 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u0924\u093e \u0939\u0948?<a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\"> \u0935\u0940\u0938\u0940\u092c\u0940<\/a> \u092f\u093e <a href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/\" data-type=\"page\" data-id=\"1186\">\u0938\u0902\u092a\u0930\u094d\u0915\u0915<\/a>?<\/h3>\n\n\n\n<p>\u0906\u092a VCBs \u0915\u0940 \u091c\u093e\u0901\u091a \u0939\u0930 1 \u0938\u0947 3 \u0938\u093e\u0932 \u092e\u0947\u0902 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0940 \u091c\u093e\u0901\u091a \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0939\u0930 \u0915\u0941\u091b \u092e\u0939\u0940\u0928\u094b\u0902 \u092e\u0947\u0902\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u094b \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0935\u0947 \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"do-vcbs-and-contactors-cause-voltage-spikes\">\u0915\u094d\u092f\u093e \u0935\u0940\u0938\u0940\u092c\u0940 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 (VCBs) \u0915\u0930\u0902\u091f \u092e\u0947\u0902 \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915\u094d\u0938 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 \u0913\u0935\u0930\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u094b\u0916\u093f\u092e\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0936\u093e\u092f\u0926 \u0939\u0940 \u0915\u092d\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u092a\u093e\u0907\u0915\u094d\u0938 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"which-device-lasts-longer-a-vcb-or-a-contactor\">\u0915\u094c\u0928 \u0938\u093e \u0909\u092a\u0915\u0930\u0923 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0924\u093e \u0939\u0948, VCB \u092f\u093e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930?<\/h3>\n\n\n\n<p>\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u092d\u0940-\u0915\u092d\u093e\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u092a\u0930 VCBs \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0909\u092a\u0915\u0930\u0923 \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-control-both-devices-remotely\">\u0915\u094d\u092f\u093e \u0906\u092a \u0926\u094b\u0928\u094b\u0902 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0926\u0942\u0930 \u0938\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0906\u092a VCBs \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u0926\u0942\u0930 \u0938\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0926\u0942\u0930\u0938\u094d\u0925 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f, \u0930\u093f\u0932\u0947 \u092f\u093e \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0938\u0941\u091d\u093e\u0935: \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u092e\u0947\u0902 \u0928\u093f\u0939\u093f\u0924 \u0939\u0948: VCB \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>","protected":false},"author":3,"featured_media":1535,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-1537","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=1537"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1537\/revisions"}],"predecessor-version":[{"id":3526,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1537\/revisions\/3526"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/1535"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=1537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=1537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=1537"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}