{"id":1583,"date":"2025-11-29T21:20:58","date_gmt":"2025-11-29T21:20:58","guid":{"rendered":"https:\/\/xbrele.com\/essential-dry-type-transformer-maintenance-steps-guide\/"},"modified":"2026-04-07T14:53:52","modified_gmt":"2026-04-07T14:53:52","slug":"essential-dry-type-transformer-maintenance-steps-guide","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/essential-dry-type-transformer-maintenance-steps-guide\/","title":{"rendered":"\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u091a\u0930\u0923"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/11110224e6134770b1eec3e3d0916d2f.jpg\" alt=\"\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u091a\u0930\u0923\" class=\"wp-image-1581\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/11110224e6134770b1eec3e3d0916d2f.jpg 1408w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/11110224e6134770b1eec3e3d0916d2f-300x164.jpg 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/11110224e6134770b1eec3e3d0916d2f-1024x559.jpg 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/11110224e6134770b1eec3e3d0916d2f-768x419.jpg 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/11110224e6134770b1eec3e3d0916d2f-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u090f\u0915 \u092e\u091c\u092c\u0942\u0924 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0926\u0940\u0930\u094d\u0918\u093e\u092f\u0941 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0917\u0939\u0928 \u0938\u092b\u093e\u0908 \u092e\u0939\u0902\u0917\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0914\u0930 \u0938\u0947\u0935\u093e \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0926\u0943\u0936\u094d\u092f \u091c\u093e\u0902\u091a \u0914\u0930 \u0935\u094d\u092f\u093e\u092a\u0915 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u0940 \u0909\u092a\u0947\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0947 \u092a\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 \u092f\u093e \u0909\u0938\u0915\u0940 \u0906\u092f\u0941 \u0915\u092e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0915\u093e\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902:<\/p><ul><li><p>\u0916\u0930\u093e\u092c \u0938\u0940\u0932 \u092f\u093e \u0915\u092e\u091c\u094b\u0930 \u091c\u094b\u0921\u093c \u0938\u0947 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u0928\u092e\u0940<\/p><\/li><li><p>\u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u092c\u094d\u0930\u0940\u0926\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928<\/p><\/li><li><p>\u092f\u0947 \u0915\u093e\u0930\u0915 \u0926\u0947\u0936\u092d\u0930 \u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0947 90% \u092e\u0947\u0902 \u092f\u094b\u0917\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/p><\/li><\/ul><\/blockquote>\n\n\n\n<p>\u0905\u092a\u0928\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0938\u0915\u094d\u0930\u093f\u092f, \u0938\u0941\u0930\u0915\u094d\u0937\u093e-\u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0905\u092a\u0928\u093e\u090f\u0901 \u0914\u0930 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0938\u0947 \u092c\u091a\u0947\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u092e\u0941\u0916\u094d\u092f \u092c\u093e\u0924\u0947\u0902<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0924\u094d\u092f\u0902\u0924 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0902\u0964 \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0926\u0943\u0936\u094d\u092f \u091c\u093e\u0902\u091a \u0914\u0930 \u0935\u094d\u092f\u093e\u092a\u0915 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u091a\u0932 \u0938\u0915\u0947\u0964.<\/p><\/li><li><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0909\u091a\u093f\u0924 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 (PPE) \u092a\u0939\u0928\u0947\u0902\u0964 \u0907\u0938\u092e\u0947\u0902 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0926\u0938\u094d\u0924\u093e\u0928\u0947, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u0936\u094d\u092e\u093e \u0914\u0930 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u092a\u0921\u093c\u0947 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>\u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0916\u094d\u0924\u0940 \u0938\u0947 \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f \u0915\u094b \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0930\u0939\u093f\u0924 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0939\u094b\u0964.<\/p><\/li><li><p>\u0915\u093e\u0930\u094d\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0938\u094d\u0935\u091a\u094d\u091b \u0930\u0916\u0947\u0902\u0964 \u092e\u0932\u092c\u0947 \u0915\u094b \u0939\u091f\u093e\u090f\u0901 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0938\u0947 \u092c\u091a\u093e\u0935 \u0924\u0925\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092c\u0922\u093c\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u093f\u0924 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0938\u092c \u0915\u0941\u091b \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0915\u0930\u0947\u0902 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0917\u0924\u093f\u0935\u093f\u0927\u093f\u092f\u093e\u0901<\/a>. \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902, \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937\u094b\u0902 \u0914\u0930 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0930\u0916\u0947\u0902\u0964.<\/p><\/li><li><p>\u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0917\u0930\u094d\u092e\u0940 \u0914\u0930 \u0928\u092e\u0940 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u092a\u0930 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0930\u0916\u0947\u0902\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0930\u0902\u0917 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928, \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0902\u0927 \u092f\u093e \u0906\u0935\u093e\u091c\u093c\u094b\u0902 \u0915\u093e \u0924\u0941\u0930\u0902\u0924 \u0938\u092e\u093e\u0927\u093e\u0928 \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u0928 \u0939\u094b\u0902\u0964.<\/p><\/li><li><p>\u0905\u092a\u0928\u0947 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u092d\u0940 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u094b \u0938\u092e\u091d\u0924\u0947 \u0939\u0948\u0902 \u0924\u093e\u0915\u093f \u091c\u094b\u0916\u093f\u092e \u0915\u092e \u0939\u094b \u0938\u0915\u0947\u0902 \u0914\u0930 \u0926\u0915\u094d\u0937\u0924\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0939\u094b \u0938\u0915\u0947\u0964.<\/p><\/li><li><p>\u0928\u093f\u0935\u093e\u0930\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0938\u092d\u0940 \u0906\u0935\u0936\u094d\u092f\u0915 \u0915\u093e\u0930\u094d\u092f \u092a\u0942\u0930\u0947 \u0939\u094b \u091c\u093e\u090f\u0901 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0941\u091b \u092d\u0940 \u0905\u0928\u0926\u0947\u0916\u093e \u0928 \u0939\u094b\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u093e\u0935\u0927\u093e\u0928\u093f\u092f\u093e\u0901<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092a\u0940\u092a\u0940\u0908 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n\n\n\n<p>\u0915\u093f\u0938\u0940 \u092d\u0940 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0906\u092a\u0915\u094b \u0938\u0939\u0940 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 (PPE) \u092a\u0939\u0928\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u093e\u0930\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0926\u0938\u094d\u0924\u093e\u0928\u0947, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u0936\u094d\u092e\u093e \u0914\u0930 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u092a\u0921\u093c\u0947 \u091a\u0941\u0928\u0947\u0902\u0964 \u0917\u093f\u0930\u0924\u0940 \u0939\u0941\u0908 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0914\u0930 \u0906\u0915\u0938\u094d\u092e\u093f\u0915 \u091f\u0915\u094d\u0915\u0930\u094b\u0902 \u0938\u0947 \u0916\u0941\u0926 \u0915\u094b \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u093e\u0930\u094d\u0921 \u0939\u0948\u091f \u0914\u0930 \u0938\u094d\u091f\u0940\u0932-\u091f\u094b \u092c\u0942\u091f\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a \u0936\u094b\u0930\u0917\u0941\u0932 \u0935\u093e\u0932\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u094b \u0936\u094d\u0930\u0935\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u0941\u0928\u0947\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0909\u092a\u092f\u094b\u0917 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092a\u0940\u092a\u0940\u0908 \u0915\u093e \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0918\u093f\u0938\u093e\u0935\u091f \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0910\u0938\u0940 \u0935\u0938\u094d\u0924\u0941 \u0915\u094b \u092c\u0926\u0932\u0947\u0902 \u091c\u093f\u0938\u092e\u0947\u0902 \u0915\u094d\u0937\u092f \u0915\u0947 \u0932\u0915\u094d\u0937\u0923 \u0926\u093f\u0916\u0947\u0902\u0964 \u0909\u091a\u093f\u0924 \u092a\u0940\u092a\u0940\u0908 \u0938\u0947 \u0906\u092a\u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091d\u091f\u0915\u0947, \u091c\u0932\u0928\u0947 \u0914\u0930 \u0905\u0928\u094d\u092f \u091a\u094b\u091f\u094b\u0902 \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0915\u093e\u0930\u094d\u092f\u0938\u094d\u0925\u0932 \u092a\u0930 \u0906\u0935\u0936\u094d\u092f\u0915 \u092a\u0940\u092a\u0940\u0908 \u0915\u0940 \u090f\u0915 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0907\u0938\u0947 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u0947 \u0938\u093e\u0925 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u0915\u0947 \u091a\u0930\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0938\u0916\u094d\u0924 \u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u092c\u0902\u0926 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0907\u0938\u0947 \u0938\u092d\u0940 \u092c\u093f\u091c\u0932\u0940 \u0938\u094d\u0930\u094b\u0924\u094b\u0902 \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930 \u0926\u0947\u0902\u0964 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0914\u0930 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092a\u0930 \u0932\u0949\u0915\u0906\u0909\u091f \u0909\u092a\u0915\u0930\u0923 \u0932\u0917\u093e\u090f\u0901\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0909\u092a\u0915\u0930\u0923 \u092a\u0930 \u091f\u0948\u0917 \u0932\u0917\u093e\u090f\u0901 \u0924\u093e\u0915\u093f \u0926\u0942\u0938\u0930\u094b\u0902 \u0915\u094b \u092a\u0924\u093e \u091a\u0932\u0947 \u0915\u093f \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0932 \u0930\u0939\u093e \u0939\u0948\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0918\u091f\u0915 \u0915\u094b \u091b\u0942\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0930\u0939\u093f\u0924 \u0939\u0948\u0964 \u0936\u0942\u0928\u094d\u092f \u090a\u0930\u094d\u091c\u093e \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0947 \u0932\u093f\u090f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091f\u0947\u0938\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0915\u0947\u0935\u0932 \u0905\u0927\u093f\u0915\u0943\u0924 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u0939\u0940 \u0915\u093e\u0930\u094d\u092f \u092a\u0942\u0930\u093e \u0939\u094b\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u0909\u092a\u0915\u0930\u0923 \u0939\u091f\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u0915\u0947 \u091a\u0930\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092c\u0902\u0926 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u092d\u0940 \u092c\u093f\u091c\u0932\u0940 \u0938\u094d\u0930\u094b\u0924\u094b\u0902 \u0938\u0947 \u092c\u0902\u0926 \u0915\u0930 \u0926\u0947\u0902 \u0914\u0930 \u0905\u0932\u0917 \u0915\u0930 \u0926\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u0949\u0915\u0906\u0909\u091f \u0909\u092a\u0915\u0930\u0923 \u0938\u0902\u0932\u0917\u094d\u0928 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0935\u0936 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d \u092a\u094d\u0930\u0935\u093e\u0939 \u0938\u0947 \u092c\u091a\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0935\u093f\u091a \u0914\u0930 \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u091f\u0948\u0917 \u0932\u0917\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u094d\u092f \u0932\u094b\u0917\u094b\u0902 \u0915\u094b \u0938\u0942\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0909\u092a\u0915\u0930\u0923 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0905\u0927\u0940\u0928 \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0942\u0928\u094d\u092f \u090a\u0930\u094d\u091c\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u092e \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u0905\u0928\u0941\u092a\u0938\u094d\u0925\u093f\u0924\u093f \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u092e \u0915\u0947 \u092c\u093e\u0926 \u0909\u092a\u0915\u0930\u0923 \u0939\u091f\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0947\u0935\u0932 \u0905\u0927\u093f\u0915\u0943\u0924 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u0939\u0940 \u0924\u093e\u0932\u0947 \u0914\u0930 \u091f\u0948\u0917 \u0939\u091f\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0938\u093e\u0907\u091f \u0924\u0948\u092f\u093e\u0930\u0940<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0914\u0930 \u0915\u0941\u0936\u0932 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u093e\u0930\u094d\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0924\u0948\u092f\u093e\u0930 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964 \u0938\u093e\u0907\u091f \u0938\u0947 \u0915\u093f\u0938\u0940 \u092d\u0940 \u092e\u0932\u092c\u0947, \u0914\u091c\u093e\u0930\u094b\u0902 \u092f\u093e \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0939\u091f\u093e \u0926\u0947\u0902\u0964 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0909\u091a\u093f\u0924 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0935\u0939 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0928 \u0939\u094b\u0964 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u0947 \u092e\u093e\u0930\u094d\u0917\u094b\u0902 \u0938\u0947 \u092c\u093e\u0927\u093e\u0913\u0902 \u0915\u094b \u0939\u091f\u093e \u0926\u0947\u0902 \u0914\u0930 \u0927\u0942\u0932 \u0915\u094b \u092c\u093e\u0939\u0930 \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f \u092a\u0930 \u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0932\u0917\u093e\u090f\u0901\u0964 \u0905\u0928\u0927\u093f\u0915\u0943\u0924 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u094b \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0938\u0947 \u0926\u0942\u0930 \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0935\u0930\u094b\u0927 \u092f\u093e \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u091c\u093e\u0901\u091a\u0947\u0902 \u0915\u093f \u0926\u0943\u0936\u094d\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0915\u093e\u0936 \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0939\u0948\u0964 \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0906\u092a \u0909\u0928\u094d\u0939\u0947\u0902 \u091c\u0932\u094d\u0926\u0940 \u0938\u0947 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930 \u0938\u0915\u0947\u0902\u0964 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u0947 \u0938\u093e\u0925 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0927\u0942\u0932 \u092d\u0930\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u0939\u0930 \u0924\u0940\u0928 \u0938\u0947 \u091b\u0939 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902 \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0938\u094d\u0935\u091a\u094d\u091b \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u092e\u0947\u0902 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u091c\u093e\u0902\u091a \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0907\u0928\u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u0939\u094b\u0917\u093e\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932<\/a> \u0905\u092a\u0928\u0947 \u0906\u092a \u0915\u094b \u0914\u0930 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u092e\u0947\u0902 \u0938\u0942\u0916\u0940 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f OSHA \u0914\u0930 IEC \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0906\u0935\u0936\u094d\u092f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u0938\u093e\u0930\u093e\u0902\u0936 \u0926\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0915\u093e\u0930\u094d\u092f \u0915\u0947\u0935\u0932 \u0924\u092c \u0939\u0940 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u091a\u093e\u0939\u093f\u090f \u091c\u092c \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0928 \u0939\u094b\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0909\u091a\u093f\u0924 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0935\u0930\u094b\u0927 \u0915\u094b \u0939\u091f\u093e \u0926\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0927\u0942\u0932 \u092d\u0930\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u0939\u0930 \u0924\u0940\u0928 \u0938\u0947 \u091b\u0939 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902; \u0938\u094d\u0935\u091a\u094d\u091b \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u092e\u0947\u0902 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u092b\u093e\u0908 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u092c\u093f\u0928\u093e \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0901\u091a\u093e\u090f \u0938\u093e\u092b \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0914\u0930 \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0915\u0938\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0922\u0940\u0932\u093e \u0939\u094b\u0928\u0947 \u0938\u0947 \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u0939\u0941\u0901\u091a \u092f\u094b\u0917\u094d\u092f \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0915\u094b \u0915\u0938\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u091c\u093e\u0902\u091a \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091c\u0902\u0917, \u0930\u0902\u0917\u0924 \u092e\u0947\u0902 \u092c\u0926\u0932\u093e\u0935 \u092f\u093e \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923 \u0926\u0947\u0916\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0927\u0942\u0932 \u0915\u0947 \u091c\u092e\u093e\u0935 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0914\u0930 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092a\u0930 \u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0914\u0930 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0915\u093e\u0930\u094d\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0914\u0930 \u0909\u092a\u0915\u0930\u0923 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u092d\u0940 \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092f\u094b\u091c\u0928\u093e<\/h3>\n\n\n\n<p>\u0915\u093f\u0938\u0940 \u092d\u0940 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0906\u092a\u0915\u094b \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0924\u0948\u092f\u093e\u0930\u0940 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u093e\u092f\u094b\u0902 \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926 \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u090f\u0902 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964 \u090f\u0915 \u092e\u091c\u092c\u0942\u0924 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092f\u094b\u091c\u0928\u093e \u0906\u092a\u0915\u094b \u0914\u0930 \u0906\u092a\u0915\u0940 \u091f\u0940\u092e \u0915\u094b \u0917\u0902\u092d\u0940\u0930 \u0928\u0941\u0915\u0938\u093e\u0928 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0915\u0947 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u0907\u0928\u092e\u0947\u0902 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091d\u091f\u0915\u093e, \u0906\u0917, \u0906\u0930\u094d\u0915 \u092b\u094d\u0932\u0948\u0936 \u092f\u093e \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092c\u0947\u0939\u094b\u0936\u0940 \u092f\u093e \u0917\u093f\u0930\u0924\u0940 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0938\u0947 \u091a\u094b\u091f \u091c\u0948\u0938\u0940 \u091a\u093f\u0915\u093f\u0924\u094d\u0938\u093e \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092a\u0930 \u092d\u0940 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u092a\u0928\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0906\u092a \u0938\u092c\u0938\u0947 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0916\u0924\u0930\u094b\u0902 \u0915\u094b \u0938\u092e\u091d \u0938\u0915\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 \u0938\u094d\u092a\u0937\u094d\u091f \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u090f\u0901\u0964 \u0907\u0938 \u092f\u094b\u091c\u0928\u093e \u092e\u0947\u0902 \u092f\u0939 \u092c\u0924\u093e\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0915\u093f \u092f\u0926\u093f \u0915\u094b\u0908 \u0918\u091f\u0928\u093e \u0939\u094b\u0924\u0940 \u0939\u0948 \u0924\u094b \u0906\u092a\u0915\u094b \u0914\u0930 \u0906\u092a\u0915\u0940 \u091f\u0940\u092e \u0915\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u0939\u0948\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u0940\u092e \u0938\u0926\u0938\u094d\u092f \u0915\u094b \u092d\u0942\u092e\u093f\u0915\u093e\u090f\u0901 \u0938\u094c\u0902\u092a\u0947\u0902\u0964 \u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, \u090f\u0915 \u0935\u094d\u092f\u0915\u094d\u0924\u093f \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u0938\u0947\u0935\u093e\u0913\u0902 \u0915\u094b \u0915\u0949\u0932 \u0915\u0930\u0947, \u091c\u092c\u0915\u093f \u0926\u0942\u0938\u0930\u093e \u0928\u093f\u0915\u093e\u0938\u0940 \u0915\u093e \u0928\u0947\u0924\u0943\u0924\u094d\u0935 \u0915\u0930\u0947\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0939\u0930 \u0915\u094b\u0908 \u0905\u092a\u0928\u0940 \u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930\u093f\u092f\u093e\u0901 \u091c\u093e\u0928\u0924\u093e \u0939\u094b\u0964.<\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u0947 \u092a\u093e\u0938 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0940 \u091c\u0917\u0939\u094b\u0902 \u092a\u0930 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u0928\u0902\u092c\u0930 \u092a\u094b\u0938\u094d\u091f \u0915\u0930\u0947\u0902\u0964 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0928\u0902\u092c\u0930 \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0905\u0917\u094d\u0928\u093f\u0936\u092e\u0928 \u0935\u093f\u092d\u093e\u0917<\/p><\/li><li><p>\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u091a\u093f\u0915\u093f\u0924\u094d\u0938\u093e \u0938\u0947\u0935\u093e\u090f\u0901 (\u0908\u090f\u092e\u090f\u0938)<\/p><\/li><li><p>\u0938\u0941\u0935\u093f\u0927\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/p><\/li><li><p>\u0938\u094d\u0925\u0932 \u092a\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0927\u093f\u0915\u093e\u0930\u0940<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0905\u092a\u0928\u0947 \u092e\u094b\u092c\u093e\u0907\u0932 \u092b\u094b\u0928 \u092e\u0947\u0902 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0939\u0947\u091c\u0947\u0902 \u0914\u0930 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u092d\u0940 \u0910\u0938\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u094b\u0924\u094d\u0938\u093e\u0939\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0928\u093f\u0915\u093e\u0938\u0940 \u092e\u093e\u0930\u094d\u0917 \u0914\u0930 \u0907\u0915\u091f\u094d\u0920\u093e \u0939\u094b\u0928\u0947 \u0915\u0947 \u092c\u093f\u0902\u0926\u0941 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0939\u094b\u0902\u0917\u0947\u0964 \u0907\u0928 \u092e\u093e\u0930\u094d\u0917\u094b\u0902 \u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0938\u0947 \u091a\u093f\u0939\u094d\u0928\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u0915\u092e \u0938\u0947 \u0915\u092e \u0938\u093e\u0932 \u092e\u0947\u0902 \u0926\u094b \u092c\u093e\u0930 \u0928\u093f\u0915\u093e\u0938\u0940 \u0905\u092d\u094d\u092f\u093e\u0938 \u0915\u0930\u0947\u0902\u0964 \u092f\u0947 \u0905\u092d\u094d\u092f\u093e\u0938 \u0906\u092a\u0915\u0940 \u091f\u0940\u092e \u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0914\u0930 \u0936\u093e\u0902\u0924\u093f\u092a\u0942\u0930\u094d\u0935\u0915 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0926\u0947\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092a\u094d\u0930\u0925\u092e \u091a\u093f\u0915\u093f\u0924\u094d\u0938\u093e \u0915\u093f\u091f \u0914\u0930 \u0905\u0917\u094d\u0928\u093f\u0936\u093e\u092e\u0915 \u092f\u0902\u0924\u094d\u0930 \u0915\u093e\u0930\u094d\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u0947 \u092a\u093e\u0938 \u0930\u0916\u0947\u0902\u0964 \u0907\u0928 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b \u0938\u0915\u0947 \u0915\u093f \u0935\u0947 \u0920\u0940\u0915 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930 \u0930\u0939\u0947 \u0939\u0948\u0902\u0964 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u0905\u0917\u094d\u0928\u093f\u0936\u093e\u092e\u0915 \u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0914\u0930 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u091a\u093f\u0915\u093f\u0924\u094d\u0938\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0926\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0928\u093f\u0915\u091f\u0924\u092e \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u092c\u093e\u0939\u094d\u092f \u0921\u093f\u092b\u093f\u092c\u094d\u0930\u093f\u0932\u0947\u091f\u0930 (AED) \u0915\u093e \u0938\u094d\u0925\u093e\u0928 \u092d\u0940 \u092a\u0924\u093e \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0938\u0930\u0932 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092f\u094b\u091c\u0928\u093e \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092f\u094b\u091c\u0928\u093e \u0915\u093e\u0930\u094d\u092f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0943\u0924\u094d\u0924\u093f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930 \u0935\u094d\u092f\u0915\u094d\u0924\u093f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u092f\u094b\u091c\u0928\u093e \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0930\u094d\u0937\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0927\u093f\u0915\u093e\u0930\u0940<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0905\u092a\u0921\u0947\u091f \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0935\u093f\u0927\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0915<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u0925\u092e \u091a\u093f\u0915\u093f\u0924\u094d\u0938\u093e \u0915\u093f\u091f\/\u0905\u0917\u094d\u0928\u093f\u0936\u093e\u092e\u0915 \u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u0930\u094d\u092f\u0935\u0947\u0915\u094d\u0937\u0915<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u0937\u094d\u0915\u093e\u0938\u0928 \u0905\u092d\u094d\u092f\u093e\u0938 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091b\u092e\u093e\u0939\u0940<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u092d\u0940 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u0925\u092e \u091a\u093f\u0915\u093f\u0924\u094d\u0938\u093e\/\u0905\u0917\u094d\u0928\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u0947\u0902 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0930\u094d\u0937\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0915<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u092d\u0940 \u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u0940, \u091a\u093e\u0939\u0947 \u0935\u0947 \u092e\u093e\u092e\u0942\u0932\u0940 \u0939\u0940 \u0915\u094d\u092f\u094b\u0902 \u0928 \u0939\u094b\u0902, \u0905\u092a\u0928\u0947 \u092a\u0930\u094d\u092f\u0935\u0947\u0915\u094d\u0937\u0915 \u0915\u094b \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938\u0938\u0947 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0940 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092f\u094b\u091c\u0928\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0939\u094b\u0924\u093e \u0939\u0948 \u0914\u0930 \u0926\u094b\u092c\u093e\u0930\u093e \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u090f\u0915 \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0905\u092d\u094d\u092f\u093e\u0938 \u0915\u0940 \u0917\u0908 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092f\u094b\u091c\u0928\u093e \u091c\u093e\u0928 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u0902\u092a\u0924\u094d\u0924\u093f \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0926\u093f\u0928\u091a\u0930\u094d\u092f\u093e \u092e\u0947\u0902 \u0907\u0938 \u091a\u0930\u0923 \u0915\u094b \u0928 \u091b\u094b\u0921\u093c\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0915\u0930 \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0915\u093e\u0930\u094d\u092f\u0938\u094d\u0925\u0932 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u0940 \u0924\u0948\u092f\u093e\u0930\u0940 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948 \u0915\u093f \u092f\u0926\u093f \u0915\u0941\u091b \u0917\u0932\u0924 \u0939\u094b \u091c\u093e\u090f \u0924\u094b \u0939\u0930 \u0915\u094b\u0908 \u091c\u093e\u0928\u0924\u093e \u0939\u0948 \u0915\u093f \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935: \u090f\u0915 \u0938\u0902\u092a\u0942\u0930\u094d\u0923 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/FDcgCWQC0Dk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u091c\u093e\u0901\u091a\u0947\u0902<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u0915\u0947 \u0939\u093f\u0938\u094d\u0938\u0947 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u093f\u0928\u091a\u0930\u094d\u092f\u093e<\/a>. \u092f\u0947 \u091c\u093e\u0902\u091a\u0947\u0902 \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0917\u0902\u092d\u0940\u0930 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0915\u0921\u093c\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0918\u0942\u092e\u0947\u0902 \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u091a\u0940\u091c\u093c \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902\u0964 \u0905\u0902\u0927\u0947\u0930\u0947 \u0915\u094b\u0928\u094b\u0902 \u0914\u0930 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u092a\u0940\u091b\u0947 \u0926\u0947\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0906\u092a \u0905\u092a\u0928\u0947 \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937\u094b\u0902 \u0915\u094b \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0910\u0938\u0947 \u092a\u0948\u091f\u0930\u094d\u0928 \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u091c\u094b \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b \u0930\u0939\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u092e\u093e\u0907\u0902\u0921\u0930 \u0938\u0947\u091f \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0906\u092a \u0915\u092d\u0940 \u092d\u0940 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u091c\u093e\u0902\u091a \u0928 \u091a\u0942\u0915\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0918\u093f\u0938\u093e\u0935 \u092f\u093e \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0939\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0918\u093f\u0938\u093e\u0935 \u092f\u093e \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u092a\u0930 \u0906\u092a\u0915\u094b \u092c\u093e\u0930\u0940\u0915\u0940 \u0938\u0947 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u092e\u0939\u0902\u0917\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0914\u0930 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948\u0964 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0926\u0943\u0936\u094d\u092f \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0915\u094d\u0932\u0948\u092e\u094d\u092a\u094d\u0938 \u0914\u0930 \u0915\u094b\u0930 \u0938\u094d\u091f\u0940\u0932 \u092a\u0930 \u091c\u0902\u0917<\/p><\/li><li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u0930 \u0915\u093e\u0930\u094d\u092c\u0928\u093e\u0907\u091c\u0947\u0936\u0928 \u092f\u093e \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917<\/p><\/li><li><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u0938\u0924\u0939\u094b\u0902 \u0915\u093e \u0930\u0902\u0917 \u092b\u0940\u0915\u093e \u092a\u0921\u093c \u091c\u093e\u0928\u093e, \u091c\u094b \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u092f\u093e \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u092c\u093e\u0930-\u092c\u093e\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0906\u092a \u0907\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u092c\u0922\u093c\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0939\u091a\u093e\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0915\u0947 \u0930\u093f\u0938\u093e\u0935, \u091c\u0902\u0917 \u0914\u0930 \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u0939\u0941\u0908 \u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u0940 \u092d\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a \u0907\u0928\u092e\u0947\u0902 \u0938\u0947 \u0915\u094b\u0908 \u092d\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0926\u0947\u0916\u0947\u0902, \u0924\u094b \u0924\u0941\u0930\u0902\u0924 \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u0915\u0930\u0947\u0902 \u0914\u0930 \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0918\u093f\u0938\u093e\u0935 \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0932\u0915\u094d\u0937\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0947 \u0915\u094d\u092f\u093e \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u094d\u0932\u0948\u092e\u094d\u092a\/\u0915\u094b\u0930 \u0938\u094d\u091f\u0940\u0932 \u092a\u0930 \u091c\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0915\u093e \u092a\u094d\u0930\u0935\u0947\u0936, \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0915\u093e\u0930\u094d\u092c\u0928\u0940\u0915\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u0930\u0902\u0917 \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u093e, \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0947\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0940\u0932 \u0935\u093f\u092b\u0932\u0924\u093e, \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0938\u0902\u0926\u0942\u0937\u0923<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0924\u0928\u093e\u0935, \u0906\u0918\u093e\u0924<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0906\u092a\u0915\u094b \u0918\u093f\u0938\u093e\u0935, \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u0930\u0923 \u0915\u0947 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u0935\u0927\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u092c\u0922\u093c\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u092e\u0947\u0902 \u092f\u094b\u0917\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0927\u0942\u0932 \u0914\u0930 \u0917\u0902\u0926\u0917\u0940 \u0915\u093e \u091c\u092e\u093e\u0935<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0927\u0942\u0932 \u0914\u0930 \u0917\u0902\u0926\u0917\u0940 \u0915\u0947 \u091c\u092e\u093e\u0935 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0927\u0942\u0932 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u092c\u093e\u0927\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0917\u0902\u0926\u0917\u0940 \u0928\u092e\u0940 \u0915\u094b \u0906\u0915\u0930\u094d\u0937\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0916\u0930\u093e\u092c\u0940 \u0906 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902, \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092e\u0947\u0902 \u0915\u093f\u0938\u0940 \u092d\u0940 \u091c\u092e\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0907\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092f\u093e \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0938\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964 \u0909\u091a\u093f\u0924 \u0915\u0942\u0932\u093f\u0902\u0917 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092e\u093e\u0930\u094d\u0917\u094b\u0902 \u0938\u0947 \u0905\u0935\u0930\u094b\u0927 \u0939\u091f\u093e\u090f\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u092a\u0902\u0916\u094b\u0902 \u092a\u0930 \u0927\u0942\u0932 \u0926\u0915\u094d\u0937\u0924\u093e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964<\/p><\/li><li><p>\u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092e\u0947\u0902 \u0927\u0942\u0932 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u0940 \u0939\u0948\u0964<\/p><\/li><li><p>\u091c\u092e\u093e \u0939\u0941\u0906 \u092e\u0932\u092c\u093e \u0916\u0930\u093e\u092c \u0938\u093e\u0907\u091f \u0939\u093e\u0909\u0938\u0915\u0940\u092a\u093f\u0902\u0917 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948\u0964<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0915\u0941\u0936\u0932\u0924\u093e\u092a\u0942\u0930\u094d\u0935\u0915 \u091a\u0932\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0927\u0942\u0932 \u0914\u0930 \u0917\u0902\u0926\u0917\u0940 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964 \u0938\u093e\u092b-\u0938\u0941\u0925\u0930\u093e \u092a\u0930\u093f\u0935\u0947\u0936 \u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u092a\u0939\u091a\u093e\u0928\u0928\u093e \u092d\u0940 \u0906\u0938\u093e\u0928 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0927\u0942\u0932 \u092d\u0930\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0939\u0930 \u0924\u0940\u0928 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902 \u090f\u0915 \u092c\u093e\u0930 \u092c\u0922\u093c\u093e \u0926\u0947\u0902\u0964 \u0938\u094d\u0935\u091a\u094d\u091b \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u091c\u093e\u0901\u091a \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0918\u0941\u092e\u093e\u0935\u0926\u093e\u0930 \u0938\u0924\u0939 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0926\u0943\u0936\u094d\u092f \u091c\u093e\u0902\u091a \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908-\u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0938\u0924\u0939\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0928 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0940\u0927\u0947 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u0947 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e, \u0926\u0930\u093e\u0930\u0947\u0902 \u0914\u0930 \u091c\u092e\u093e\u0935 \u091c\u0948\u0938\u0940 \u091a\u0940\u091c\u093c\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u091c\u094b \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0939\u093f\u0924 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0930\u0902\u0917 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0915\u0947 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u092d\u0942\u0930\u0947 \u092f\u093e \u0915\u093e\u0932\u0947 \u0927\u092c\u094d\u092c\u0947 \u0905\u0915\u094d\u0938\u0930 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0938\u092b\u0947\u0926 \u092f\u093e \u091a\u0942\u0928\u093e-\u0938\u093e \u0905\u0935\u0936\u0947\u0937 \u0926\u0947\u0916 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u0948\u0964 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0915\u0940 \u0938\u0924\u0939 \u092a\u0930 \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u092b\u091f\u0928\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0924\u0928\u093e\u0935 \u092f\u093e \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0927\u0942\u0932, \u0924\u0947\u0932 \u092f\u093e \u0928\u092e\u0940 \u091c\u0948\u0938\u0940 \u0935\u093f\u0926\u0947\u0936\u0940 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0940 \u092d\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0926\u0942\u0937\u093f\u0924 \u092a\u0926\u093e\u0930\u094d\u0925 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0915\u0920\u093f\u0928-\u0938\u0947-\u092a\u0939\u0941\u0902\u091a\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u091a\u0932\u0947\u0902 \u0914\u0930 \u092a\u0942\u0930\u0940 \u0918\u0941\u092e\u093e\u0935\u0926\u093e\u0930 \u0938\u0924\u0939 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0915\u094b\u0928\u094b\u0902 \u0914\u0930 \u0915\u093f\u0928\u093e\u0930\u094b\u0902 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902, \u091c\u0939\u093e\u0901 \u0905\u0915\u094d\u0938\u0930 \u0915\u094d\u0937\u0924\u093f \u0936\u0941\u0930\u0942 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0902\u0927, \u091c\u0948\u0938\u0947 \u091c\u0932\u0928\u0947 \u0915\u0940 \u0917\u0902\u0927, \u092e\u0939\u0938\u0942\u0938 \u0939\u094b \u0924\u094b \u0906\u0917\u0947 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0905\u0935\u0932\u094b\u0915\u0928 \u0915\u094b \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0938\u0902\u092d\u0935 \u0939\u094b \u0924\u094b \u0924\u0938\u094d\u0935\u0940\u0930\u0947\u0902 \u092d\u0940 \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0918\u0941\u092e\u093e\u0935\u0926\u093e\u0930 \u0938\u0924\u0939\u094b\u0902 \u0915\u094b \u0939\u092e\u0947\u0936\u093e \u0938\u093e\u092b \u0914\u0930 \u0938\u0942\u0916\u093e \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0927\u0942\u0932 \u0914\u0930 \u0928\u092e\u0940 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0922\u0940\u0932\u0947 \u0915\u0923\u094b\u0902 \u0915\u094b \u0939\u091f\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092f\u093e \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0917\u0940\u0932\u0947 \u0938\u092b\u093e\u0908 \u0924\u0930\u0940\u0915\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092c\u091a\u0947\u0902, \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0907\u0938\u0938\u0947 \u0928\u092e\u0940 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0940 \u092d\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0918\u0941\u092e\u093e\u0935\u0926\u093e\u0930 \u0938\u0924\u0939 \u092a\u0930 \u091a\u0932\u0924\u0940 \u0939\u0941\u0908 \u092a\u0924\u0932\u0940, \u0917\u0939\u0930\u0940 \u0930\u0947\u0916\u093e\u0913\u0902 \u0915\u094b \u0926\u0947\u0916\u0947\u0902\u0964 \u092f\u0947 \u0930\u0947\u0916\u093e\u090f\u0901 \u0926\u093f\u0916\u093e\u0924\u0940 \u0939\u0948\u0902 \u0915\u093f \u092c\u093f\u091c\u0932\u0940 \u0907\u091a\u094d\u091b\u093f\u0924 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u092c\u093e\u0939\u0930 \u0915\u093f\u0938\u0940 \u0905\u0928\u094d\u092f \u092e\u093e\u0930\u094d\u0917 \u0915\u093e \u0905\u0928\u0941\u0938\u0930\u0923 \u0915\u0930 \u091a\u0941\u0915\u0940 \u0939\u0948\u0964 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0938\u0924\u0939 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0914\u0930 \u0909\u0928\u0915\u0947 \u092a\u094d\u0930\u092d\u093e\u0935\u094b\u0902 \u0915\u093e \u0938\u093e\u0930\u093e\u0902\u0936 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0940 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u0915\u094d\u0930\u093e\u0915\u093e\u0930 \u0938\u0924\u0939 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0907\u0938\u0915\u093e \u0915\u094d\u092f\u093e \u092e\u0924\u0932\u092c \u0939\u0948<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e (\u092d\u0942\u0930\u093e\/\u0915\u093e\u0932\u093e)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u093e, \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u094d\u0930\u094b\u0924 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u092b\u091f\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0924\u0928\u093e\u0935, \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u092d\u093e\u0917\u094b\u0902 \u0915\u094b \u092c\u0926\u0932\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u092b\u0947\u0926\/\u091a\u0942\u0928\u093e \u091c\u0948\u0938\u093e \u0905\u0935\u0936\u0947\u0937<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0927\u0942\u0932 \u092f\u093e \u092e\u0932\u092c\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u0930\u093e\u092c \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939, \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0930\u0947\u0916\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0924\u094d\u0915\u093e\u0932 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0915\u0947 \u0927\u092c\u094d\u092c\u0947<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0942\u0937\u0923, \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0942\u0916\u093e \u0915\u094d\u0937\u0947\u0924\u094d\u0930, \u0938\u0940\u0932\u093f\u0902\u0917 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091c\u094b \u092d\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u092e\u093f\u0932\u0947, \u0909\u0938\u0947 \u0924\u0941\u0930\u0902\u0924 \u0938\u0902\u092c\u094b\u0927\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092e\u0930\u092e\u094d\u092e\u0924 \u092e\u0947\u0902 \u0926\u0947\u0930\u0940 \u0915\u0930\u0928\u0947 \u0938\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0938\u092b\u093e\u0908 \u0914\u0930 \u092e\u0930\u092e\u094d\u092e\u0924 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0918\u0941\u092e\u093e\u0935\u0926\u093e\u0930 \u0938\u0924\u0939 \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0915\u092d\u0940 \u092d\u0940 \u0905\u0928\u0926\u0947\u0916\u093e \u0928 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u092e\u093e\u092e\u0942\u0932\u0940 \u0926\u094b\u0937 \u092d\u0940 \u092f\u0926\u093f \u092c\u093f\u0928\u093e \u0909\u092a\u091a\u093e\u0930 \u0915\u0947 \u091b\u094b\u0921\u093c \u0926\u093f\u090f \u091c\u093e\u090f\u0902 \u0924\u094b \u092c\u0921\u093c\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a \u0938\u094d\u0935\u091a\u094d\u091b \u0914\u0930 \u092c\u093f\u0928\u093e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0924\u094d\u0935\u0930\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0909\u0928\u0915\u0940 \u0906\u092f\u0941 \u092c\u0922\u093c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0938\u092b\u093e\u0908 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902 \u0915\u0940 \u0938\u092b\u093e\u0908<\/h3>\n\n\n\n<p>\u0909\u091a\u093f\u0924 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902 \u0915\u094b \u0938\u093e\u092b \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0927\u0942\u0932 \u0914\u0930 \u092e\u0932\u092c\u0947 \u092a\u0902\u0916\u0947 \u0915\u0947 \u092c\u094d\u0932\u0947\u0921\u094d\u0938 \u0915\u094b \u0905\u0935\u0930\u0941\u0926\u094d\u0927 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0915\u0942\u0932\u093f\u0902\u0917 \u0926\u0915\u094d\u0937\u0924\u093e \u0915\u094b \u0915\u092e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u092c\u0902\u0926 \u0915\u0930\u0915\u0947 \u0909\u0938\u0915\u0940 \u092c\u093f\u091c\u0932\u0940 \u0915\u093e\u091f\u0947\u0902\u0964 \u092a\u0902\u0916\u0947 \u0915\u0947 \u092c\u094d\u0932\u0947\u0921\u094d\u0938 \u0914\u0930 \u0917\u094d\u0930\u093f\u0932\u094d\u0938 \u0938\u0947 \u0927\u0942\u0932 \u0915\u094b \u0922\u0940\u0932\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0928\u0930\u092e \u092c\u094d\u0930\u0936 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0922\u0940\u0932\u0947 \u0939\u0941\u090f \u0915\u0923\u094b\u0902 \u0915\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0932\u0940\u0928\u0930 \u0938\u0947 \u0939\u091f\u093e \u0926\u0947\u0902\u0964 \u091c\u093f\u0926\u094d\u0926\u0940 \u0917\u0902\u0926\u0917\u0940 \u0915\u0947 \u0932\u093f\u090f, \u0925\u094b\u0921\u093c\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u092e\u0947\u0902 \u0905\u0928\u0941\u092e\u094b\u0926\u093f\u0924 \u0915\u094d\u0932\u0940\u0928\u093f\u0902\u0917 \u0938\u0949\u0932\u094d\u092f\u0942\u0936\u0928 \u0938\u0947 \u0917\u0940\u0932\u093e \u0915\u093f\u092f\u093e \u0939\u0941\u0906 \u0932\u093f\u0902\u091f-\u092b\u094d\u0930\u0940 \u0915\u092a\u0921\u093c\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092a\u0902\u0916\u094b\u0902 \u092a\u0930 \u0938\u0940\u0927\u0947 \u0924\u0930\u0932 \u092a\u0926\u093e\u0930\u094d\u0925 \u091b\u093f\u0921\u093c\u0915\u0928\u0947 \u0938\u0947 \u092c\u091a\u0947\u0902\u0964 \u0938\u092b\u093e\u0908 \u0915\u0947 \u092c\u093e\u0926 \u0939\u092e\u0947\u0936\u093e \u091c\u093e\u0902\u091a\u0947\u0902 \u0915\u093f \u092a\u0902\u0916\u0947 \u0906\u0938\u093e\u0928\u0940 \u0938\u0947 \u0918\u0942\u092e \u0930\u0939\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0906\u0935\u093e\u091c \u092f\u093e \u0915\u0902\u092a\u0928 \u0938\u0941\u0928\u093e\u0908 \u0926\u0947, \u0924\u094b \u092a\u0902\u0916\u0947 \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902 \u0914\u0930 \u092f\u0926\u093f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u0909\u0938\u0947 \u092c\u0926\u0932 \u0926\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0927\u0942\u0932 \u092d\u0930\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902 \u0915\u094b \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0905\u092d\u094d\u092f\u093e\u0938 \u0924\u093e\u092a\u092e\u093e\u0928 \u092e\u0947\u0902 \u0905\u091a\u093e\u0928\u0915 \u0909\u091b\u093e\u0932 \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0940 \u0938\u092b\u093e\u0908<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0927\u0942\u0932 \u0914\u0930 \u0917\u0902\u0926\u0917\u0940 \u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f \u0938\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915\u0932 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0936\u0941\u0930\u0941\u0906\u0924 \u092e\u0947\u0902 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0915\u0947 \u0927\u0942\u0932, \u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u093e \u092f\u093e \u0905\u0935\u0936\u0947\u0937 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u0922\u0940\u0932\u0947 \u0915\u0923\u094b\u0902 \u0915\u094b \u0939\u091f\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0949\u092b\u094d\u091f \u092c\u094d\u0930\u0936 \u0905\u091f\u0948\u091a\u092e\u0947\u0902\u091f \u0935\u093e\u0932\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0932\u0940\u0928\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u091c\u093f\u0928 \u091c\u0917\u0939\u094b\u0902 \u0924\u0915 \u092a\u0939\u0941\u0902\u091a\u0928\u093e \u092e\u0941\u0936\u094d\u0915\u093f\u0932 \u0939\u0948, \u0935\u0939\u093e\u0902 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0936\u0941\u0937\u094d\u0915 \u0939\u0935\u093e \u0915\u093e \u091b\u094b\u091f\u0947-\u091b\u094b\u091f\u0947 \u091d\u094b\u0902\u0915\u094b\u0902 \u092e\u0947\u0902 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u094b\u091c\u0932 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0926\u0942\u0930\u0940 \u092a\u0930 \u0930\u0916\u0947\u0902\u0964 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0915\u092d\u0940 \u092d\u0940 \u092a\u093e\u0928\u0940 \u092f\u093e \u0917\u0940\u0932\u0947 \u0938\u092b\u093e\u0908 \u090f\u091c\u0947\u0902\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928 \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u091c\u093f\u0926\u094d\u0926\u0940 \u091c\u092e\u093e\u0935 \u092e\u093f\u0932\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0915\u093f\u0938\u0940 \u092d\u0940 \u0938\u092b\u093e\u0908 \u0930\u0938\u093e\u092f\u0928 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0905\u092a\u0928\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u092a\u0930\u093e\u092e\u0930\u094d\u0936 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u091c\u092e\u0940 \u0927\u0942\u0932 \u0915\u0940 \u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u092b\u093e\u0908 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u092e\u0947\u0902 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u0927\u0942\u0932 \u092d\u0930\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u092d\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092f\u093e \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917<\/h3>\n\n\n\n<p>\u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0938\u092b\u093e\u0908 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0932\u0940\u0928\u0930 \u092f\u093e \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0924\u0930\u0940\u0915\u0947 \u0928\u092e\u0940 \u092f\u093e \u0918\u0930\u094d\u0937\u0923 \u092a\u0948\u0926\u093e \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u0927\u0942\u0932 \u0939\u091f\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092b\u093e\u0908 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u092c\u093f\u091c\u0932\u0940 \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930 \u0926\u0947\u0902\u0964 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u0936\u094d\u092e\u093e \u0914\u0930 \u0927\u0942\u0932 \u092e\u093e\u0938\u094d\u0915 \u091c\u0948\u0938\u0947 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 \u092a\u0939\u0928\u0947\u0902\u0964 \u0938\u092d\u0940 \u092e\u0932\u092c\u0947 \u0915\u094b \u092a\u0915\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0924\u0939\u094b\u0902 \u092a\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0928\u094b\u091c\u0932 \u0915\u094b \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u091a\u0932\u093e\u090f\u0902\u0964 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0926\u092c\u093e\u0935 \u0915\u094b \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0938\u0940\u092e\u093e \u0938\u0947 \u0928\u0940\u091a\u0947 \u0930\u0916\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0938\u092b\u093e\u0908 \u0935\u093f\u0927\u093f\u092f\u094b\u0902 \u0915\u093e \u0938\u093e\u0930\u093e\u0902\u0936 \u092f\u0939\u093e\u0901 \u0926\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092b \u0915\u0930\u0928\u0947 \u0915\u0940 \u0935\u093f\u0927\u093f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u092e\u093f\u0924 \u091c\u093e\u0901\u091a<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0935\u0930\u0915\u094d\u0924 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u093e\u092a\u092e\u093e\u0928 \u092e\u0947\u0902 \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0917\u094d\u0930\u093f\u0932\u094b\u0902 \u0915\u0940 \u0938\u092b\u093e\u0908<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u094b\u0907\u0932 \u0935\u0948\u0915\u094d\u092f\u0942\u092e\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u094d\u0935\u091a\u094d\u091b \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0928 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0938\u094d\u0935\u091a\u094d\u091b \u0909\u092a\u0915\u0930\u0923 \u0905\u0927\u093f\u0915 \u0915\u0941\u0936\u0932\u0924\u093e \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092c\u093e\u0927\u093e\u090f\u0901 \u0939\u091f\u093e\u0928\u093e<\/h3>\n\n\n\n<p>\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0915\u0941\u0936\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0947 \u0905\u0935\u0930\u094b\u0927 \u0939\u091f\u093e\u0928\u0947 \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0935\u0930\u094b\u0927 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0948\u0902, \u0917\u0930\u094d\u092e\u0940 \u0915\u094b \u092b\u0901\u0938\u093e\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0915\u093e \u0916\u0924\u0930\u093e \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0938\u092b\u093e\u0908 \u0938\u0924\u094d\u0930 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0915\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0910\u0938\u0947 \u0909\u092a\u0915\u0930\u0923, \u092a\u0948\u0915\u0947\u091c\u093f\u0902\u0917, \u092e\u0932\u092c\u0947 \u092f\u093e \u0917\u0932\u0924 \u091c\u0917\u0939 \u0930\u0916\u0947 \u0917\u090f \u0906\u0907\u091f\u092e \u0926\u0947\u0916\u0947\u0902 \u091c\u094b \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092f\u093e \u092a\u0939\u0941\u0901\u091a \u0915\u094b \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0915\u093e \u092b\u0930\u094d\u0936 \u0916\u093e\u0932\u0940 \u0915\u0930\u0915\u0947 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u0915\u093e\u0930\u094d\u091f, \u0938\u0940\u0922\u093c\u093f\u092f\u093e\u0901 \u0914\u0930 \u092d\u0902\u0921\u093e\u0930\u0923 \u092c\u093f\u0928 \u0907\u0915\u093e\u0908 \u0938\u0947 \u0926\u0942\u0930 \u0939\u091f\u093e \u0926\u0947\u0902\u0964 \u0927\u0942\u0932, \u0917\u0902\u0926\u0917\u0940 \u0914\u0930 \u091b\u094b\u091f\u0940 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0915\u094b \u091d\u093e\u0921\u093c\u0942 \u0938\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u092a\u0940\u091b\u0947 \u092f\u093e \u0928\u0940\u091a\u0947 \u0917\u093f\u0930 \u0917\u0908 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902 \u0910\u0938\u0940 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0915\u0940 \u092d\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0902\u0927\u0947\u0930\u0947 \u0915\u094b\u0928\u094b\u0902 \u0914\u0930 \u0938\u0902\u0915\u0940\u0930\u094d\u0923 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u092e\u0947\u0902 \u0926\u0947\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u091c\u094b \u092d\u0940 \u0935\u093f\u0926\u0947\u0936\u0940 \u0935\u0938\u094d\u0924\u0941\u090f\u0902 \u0906\u092a\u0915\u094b \u092e\u093f\u0932\u0947\u0902, \u0909\u0928\u094d\u0939\u0947\u0902 \u0939\u091f\u093e \u0926\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0905\u0917\u0932\u093e, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0938\u094d\u0935\u092f\u0902 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902, \u0917\u094d\u0930\u093f\u0932\u094d\u0938 \u0914\u0930 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0906\u092a \u0907\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u092a\u0924\u094d\u0924\u093f\u092f\u093e\u0901, \u0915\u093e\u0917\u091c\u093c \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u091f\u0941\u0915\u0921\u093c\u0947 \u092b\u0901\u0938\u0947 \u0939\u0941\u090f \u092a\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0928 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0939\u091f\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0932\u0940\u0928\u0930 \u092f\u093e \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0901\u091a\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u0924\u0947\u091c \u0914\u091c\u093e\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0906\u0935\u0930\u0923 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0905\u0935\u0930\u094b\u0927\u094b\u0902 \u0915\u0940 \u092d\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0942\u0928\u093f\u091f \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0928\u0947 \u0914\u0930 \u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u0939\u0940 \u090f\u0915\u094d\u0938\u0947\u0938 \u092a\u0948\u0928\u0932 \u0916\u094b\u0932\u0947\u0902\u0964 \u0922\u0940\u0932\u0940 \u0924\u093e\u0930\u0947\u0902, \u0915\u0947\u092c\u0932 \u091f\u093e\u0908\u091c\u093c \u092f\u093e \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0926\u0947\u0916\u0947\u0902 \u091c\u094b \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u092f\u093e \u0932\u093e\u0907\u0935 \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u091b\u0942 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0928 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0915\u094b \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0939\u091f\u093e\u090f\u0901 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u094d\u0925\u093e\u0928 \u092a\u0930 \u0930\u0916\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0938\u092e\u0930\u094d\u092a\u093f\u0924 \u092d\u0902\u0921\u093e\u0930\u0923 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964 \u092f\u0939 \u0905\u092d\u094d\u092f\u093e\u0938 \u0905\u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u0915\u0938\u094d\u092e\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u092d\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0918\u091f\u0915\u094b\u0902 \u0924\u0915 \u0938\u094d\u092a\u0937\u094d\u091f \u092a\u0939\u0941\u0901\u091a \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0915\u0930\u094d\u0924\u093e\u0913\u0902 \u0915\u094b \u0906\u0917 \u092f\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092c\u093f\u0928\u093e \u0905\u0935\u0930\u094b\u0927 \u0915\u0947 \u092e\u093e\u0930\u094d\u0917 \u091a\u093e\u0939\u093f\u090f\u0964 \u0906\u092a\u0915\u094b \u091f\u0947\u092a \u092f\u093e \u0905\u0935\u0930\u094b\u0927\u0915\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0907\u0915\u093e\u0908 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u091a\u093f\u0939\u094d\u0928\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0928\u0927\u093f\u0915\u0943\u0924 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u094b \u0926\u0942\u0930 \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924 \u0932\u0917\u093e\u090f\u0901\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0939\u0948 \u091c\u094b \u0906\u092a\u0915\u094b \u0905\u0935\u0930\u094b\u0927\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0939\u091f\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0947\u0917\u0940:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u092f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0943\u0924\u094d\u0924\u093f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930 \u0935\u094d\u092f\u0915\u094d\u0924\u093f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u0941\u0932\u0940 \u092b\u0930\u094d\u0936 \u0915\u0940 \u091c\u0917\u0939<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092a\u094d\u0924\u093e\u0939\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0902\u0916\u094b\u0902 \u0938\u0947 \u092e\u0932\u092c\u093e \u0939\u091f\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0930\u0923 \u0915\u0947 \u0905\u0902\u0926\u0930 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u094b\u0917\u094d\u092f \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0940\u0936\u093f\u092f\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u091a\u093f\u0939\u094d\u0928\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0930\u094d\u0937\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0935\u093f\u0927\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0915<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0905\u0935\u0930\u094b\u0927 \u0915\u094b \u0926\u0930\u094d\u091c \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u091c\u093f\u0938\u0947 \u0906\u092a \u0939\u091f\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u094d\u0925\u093e\u0928, \u0905\u0935\u0930\u094b\u0927 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930 \u0914\u0930 \u0915\u0940 \u0917\u0908 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u094b \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u0906\u0935\u0930\u094d\u0924\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0938\u092b\u093e\u0908-\u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e \u0915\u0940 \u092a\u094d\u0930\u0925\u093e\u0913\u0902 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u092a\u093e\u0938 \u0906\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0935\u0930\u094b\u0927 \u0915\u094b \u0915\u092d\u0940 \u0928 \u0905\u0928\u0926\u0947\u0916\u093e \u0915\u0930\u0947\u0902\u0964 \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u091b\u094b\u091f\u0940-\u091b\u094b\u091f\u0940 \u0935\u0938\u094d\u0924\u0941\u090f\u0902 \u092d\u0940 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u0940 \u0939\u0948\u0902 \u0914\u0930 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964 \u0938\u092e\u092f \u092a\u0930 \u0939\u091f\u093e\u0928\u0947 \u0938\u0947 \u0906\u092a\u0915\u093e \u0909\u092a\u0915\u0930\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0939\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0938\u093e\u092b \u0930\u0916\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0915\u0941\u0936\u0932 \u0915\u093e\u0930\u094d\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0905\u0935\u0930\u094b\u0927\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0939\u091f\u093e\u0928\u0947 \u0938\u0947 \u0909\u091a\u093f\u0924 \u0915\u0942\u0932\u093f\u0902\u0917 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u091a\u093e\u0932\u0942 \u0905\u0935\u0938\u094d\u0925\u093e \u092e\u0947\u0902 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u091c\u092c \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u090a\u0930\u094d\u091c\u093e-\u092f\u0941\u0915\u094d\u0924 \u0930\u0939\u0924\u093e \u0939\u0948, \u0924\u092c \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0947\u0935\u0932 \u092f\u094b\u0917\u094d\u092f \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u0939\u0940 \u092f\u0947 \u091c\u093e\u0902\u091a\u0947\u0902 \u0915\u0930\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 \u092a\u0939\u0928\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0914\u0930 \u0938\u092d\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u092d\u0940 \u092d\u0940 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0916\u0941\u0932\u0947 \u0918\u091f\u0915 \u0915\u094b \u0928 \u091b\u0941\u090f\u0902 \u0914\u0930 \u092f\u0942\u0928\u093f\u091f \u091a\u093e\u0932\u0942 \u0939\u094b\u0928\u0947 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947, \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0938\u0947 \u092e\u0941\u0915\u094d\u0924 \u0939\u0948\u0964 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0926\u0942\u0930\u0940 \u092a\u0930 \u0916\u0921\u093c\u0947 \u0930\u0939\u0947\u0902 \u0914\u0930 \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917, \u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u0947 \u092f\u093e \u0927\u0941\u090f\u0902 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923 \u0926\u0947\u0916\u0947\u0902\u0964 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092f\u093e \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902 \u0915\u0947 \u092a\u093e\u0938 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0935\u093f\u0926\u0947\u0936\u0940 \u0935\u0938\u094d\u0924\u0941 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0906\u0935\u0930\u0923 \u092a\u0930 \u091c\u0902\u0917, \u0915\u094d\u0937\u0930\u0923 \u092f\u093e \u092a\u093e\u0928\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u093e \u092d\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u094b \u0939\u092e\u0947\u0936\u093e \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0924\u0915 \u0939\u0940 \u0938\u0940\u092e\u093f\u0924 \u0930\u0916\u0947\u0902\u0964 \u0938\u092d\u0940 \u0915\u094b \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u094b\u0924\u094d\u0938\u093e\u0939\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0905\u092a\u0928\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0902\u0938\u094d\u0915\u0943\u0924\u093f \u0935\u093f\u0915\u0938\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0909\u091a\u093f\u0924 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0924\u093e\u0915\u093f \u0938\u094d\u0925\u0948\u0924\u093f\u0915 \u092c\u093f\u091c\u0932\u0940 \u0915\u093e \u0938\u0902\u091a\u092f \u0928 \u0939\u094b\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092c\u093e\u0924, \u091c\u0948\u0938\u0947 \u091a\u093f\u0902\u0917\u093e\u0930\u093f\u092f\u093e\u0901 \u092f\u093e \u0906\u0930\u094d\u0915\u093f\u0902\u0917, \u0926\u093f\u0916\u093e\u0908 \u0926\u0947 \u0924\u094b \u0924\u0941\u0930\u0902\u0924 \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u0915\u0930\u0947\u0902 \u0914\u0930 \u0906\u0917\u0947 \u0915\u0940 \u091c\u093e\u0902\u091a \u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0927\u093e\u0930\u093e \u0930\u093f\u0938\u093e\u0935 \u0915\u093e \u0915\u094b\u0908 \u091c\u094b\u0916\u093f\u092e \u0926\u093f\u0916\u093e\u0908 \u0926\u0947 \u0924\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0914\u0930 \u0909\u0938\u0938\u0947 \u091c\u0941\u0921\u093c\u0947 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0915\u0947 \u092c\u0902\u0926 \u0915\u0930 \u0926\u0947\u0902\u0964.<\/p><\/li><li><p>\u0915\u093f\u0938\u0940 \u092d\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u092f\u093e \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e\u0930\u094d\u092f \u0915\u094b \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u092c\u093f\u091c\u0932\u0940 \u092c\u0902\u0926 \u0939\u094b\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/a> \u090a\u0930\u094d\u091c\u093e\u092f\u0941\u0915\u094d\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928\u0964 \u0924\u093e\u092a\u092e\u093e\u0928 \u092e\u0947\u0902 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b \u0930\u0939\u0947 \u0926\u094b\u0937\u094b\u0902 \u092f\u093e \u0905\u0915\u094d\u0937\u092e\u0924\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938, \u0915\u094b\u0930 \u0914\u0930 \u0906\u0935\u0930\u0923 \u0915\u0940 \u0938\u0924\u0939 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928 \u091c\u093e\u0902\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0917\u0948\u0930-\u0938\u0902\u092a\u0930\u094d\u0915 \u0907\u0928\u094d\u092b\u094d\u0930\u093e\u0930\u0947\u0921 \u0925\u0930\u094d\u092e\u093e\u092e\u0940\u091f\u0930 \u092f\u093e \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0939\u093f\u0924 \u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u0947\u0902\u0938\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u092a\u0920\u0928 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0940\u092e\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0924\u093e\u092a\u092e\u093e\u0928 \u0935\u0943\u0926\u094d\u0927\u093f \u0926\u0947\u0916\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0915\u093e\u0930\u0923 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0905\u0915\u094d\u0938\u0930 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092e\u0947\u0902 \u0905\u0935\u0930\u094b\u0927, \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0927\u0942\u0932 \u092f\u093e \u0913\u0935\u0930\u0932\u094b\u0921 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0905\u0938\u092e\u093e\u0928 \u0924\u093e\u092a\u092e\u093e\u0928 \u0935\u093f\u0924\u0930\u0923 \u0915\u0940 \u092d\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u091c\u094b \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0928\u093f\u0930\u0902\u0924\u0930 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0924\u093e\u092a\u092e\u093e\u0928 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u092f\u0947 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0906\u092a\u0915\u094b \u0938\u091a\u0947\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0947\u0902 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0940 \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u090f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u093f\u0938\u094d\u0938\u093e \u0939\u0948\u0964 \u0906\u092a \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0915\u0930 \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0909\u0928\u0915\u0940 \u0906\u092f\u0941 \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0905\u0935\u0930\u0915\u094d\u0924 \u0938\u094d\u0915\u0948\u0928<\/h3>\n\n\n\n<p>\u0907\u0928\u094d\u092b\u094d\u0930\u093e\u0930\u0947\u0921 \u0938\u094d\u0915\u0948\u0928 \u090f\u0915 \u0936\u0915\u094d\u0924\u093f\u0936\u093e\u0932\u0940, \u0917\u0948\u0930-\u0906\u0915\u094d\u0930\u093e\u092e\u0915 \u0924\u0930\u0940\u0915\u093e \u0939\u0948 \u091c\u094b \u090a\u0930\u094d\u091c\u093e \u092f\u0941\u0915\u094d\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0938\u0915\u094d\u0937\u092e \u0939\u0948\u0964 \u0906\u092a \u0925\u0930\u094d\u092e\u0932 \u0907\u092e\u0947\u091c\u093f\u0902\u0917 \u0915\u0948\u092e\u0930\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0939\u0949\u091f \u0938\u094d\u092a\u0949\u091f, \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0924\u093e\u092a \u0914\u0930 \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0916\u093e\u092e\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0935\u093f\u0927\u093f \u0906\u092a\u0915\u094b \u0938\u0947\u0935\u093e \u092c\u093e\u0927\u093f\u0924 \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u092f\u093e \u0938\u094d\u0935\u092f\u0902 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0916\u0924\u0930\u094b\u0902 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u0947\u0902 \u0932\u093e\u090f \u092c\u093f\u0928\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0907\u0928\u094d\u092b\u094d\u0930\u093e\u0930\u0947\u0921 \u0938\u094d\u0915\u0948\u0928\u093f\u0902\u0917 \u0906\u092a\u0915\u094b \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0924\u093f, \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0902 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u092c\u0947\u0902\u091a\u092e\u093e\u0930\u094d\u0915 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0938\u094d\u0915\u0948\u0928 IEC 60076-18 \u0914\u0930 IEEE C57.149 \u091c\u0948\u0938\u0947 \u0905\u0902\u0924\u0930\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0939\u0948\u0902, \u091c\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0928\u093f\u0926\u093e\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u0915\u094d\u0937<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u0936\u0940\u0918\u094d\u0930 \u092a\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u0902\u092a\u0930\u093e\u0917\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u0926\u093f\u0916\u093e\u0908 \u0928 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u094b\u0930 \u0915\u0940 \u0917\u0924\u093f, \u0935\u0947\u0902\u0921\u093f\u0902\u0917 \u0935\u093f\u0915\u0943\u0924\u093f \u0914\u0930 \u0905\u0928\u094d\u092f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u093e \u0906\u0915\u0932\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0902\u0936\u093f\u0915 \u092a\u0924\u0928 \u0914\u0930 \u091f\u0942\u091f\u0940 \u0915\u094d\u0932\u0948\u0902\u092a\u093f\u0902\u0917 \u0938\u0902\u0930\u091a\u0928\u093e\u0913\u0902 \u0938\u0939\u093f\u0924 \u0935\u0947\u0902\u0921\u093f\u0902\u0917 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0917\u0948\u0930-\u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0917\u0948\u0930-\u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a\u0915\u093e\u0930\u0940, \u091c\u094b \u091a\u093e\u0932\u0942 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u092a\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u0928\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0915\u0940 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0938\u0902\u0926\u0930\u094d\u092d \u092c\u093f\u0902\u0926\u0941 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u0905\u0928\u0941\u092a\u093e\u0932\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0928\u093f\u0926\u093e\u0928 \u0915\u0947 \u0932\u093f\u090f IEC 60076-18 \u0914\u0930 IEEE C57.149 \u091c\u0948\u0938\u0947 \u0905\u0902\u0924\u0930\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u092f\u0926\u093f \u0906\u092a \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0939\u0949\u091f \u0938\u094d\u092a\u0949\u091f \u092f\u093e \u0924\u093e\u092a\u092e\u093e\u0928 \u0935\u093f\u0938\u0902\u0917\u0924\u093f \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u092f\u0925\u093e\u0936\u0940\u0918\u094d\u0930 \u090f\u0915 \u0935\u094d\u092f\u093e\u092a\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0907\u0928\u094d\u092b\u094d\u0930\u093e\u0930\u0947\u0921 \u0938\u094d\u0915\u0948\u0928 \u0915\u094b \u0906\u092a\u0915\u0940 \u0928\u093f\u092f\u092e\u093f\u0924 \u0921\u094d\u0930\u093e\u0908-\u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u093f\u0928\u091a\u0930\u094d\u092f\u093e \u0915\u093e \u0939\u093f\u0938\u094d\u0938\u093e \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938\u0938\u0947 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u092e\u0942\u0932\u094d\u092f\u0935\u093e\u0928 \u091c\u093e\u0928\u0915\u093e\u0930\u0940 \u092e\u093f\u0932\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0906\u0935\u093e\u091c\u093c\u094b\u0902 \u092f\u093e \u0917\u0902\u0927\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092f\u0941\u0915\u094d\u0924 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0905\u092a\u0928\u0940 \u0907\u0902\u0926\u094d\u0930\u093f\u092f\u094b\u0902 \u092a\u0930 \u092d\u0930\u094b\u0938\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u094d\u0935\u0928\u093f\u092f\u093e\u0901 \u092f\u093e \u0917\u0902\u0927 \u0905\u0915\u094d\u0938\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0947 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 \u0907\u0928 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0915\u0921\u093c\u0915\u0930 \u0906\u092a \u092c\u0921\u093c\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u094d\u0935\u0928\u093f\u092f\u094b\u0902 \u0915\u094b \u0938\u0941\u0928\u0928\u093e<\/h4>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u090f\u0915 \u0938\u094d\u0935\u0938\u094d\u0925 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0941\u0928\u0917\u0941\u0928\u093e\u0939\u091f \u0938\u0947 \u0905\u0932\u0917 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0906\u0935\u093e\u091c\u093c \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0906\u0935\u093e\u091c\u093c \u0915\u093f\u0938\u0940 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u0940 \u0913\u0930 \u0907\u0936\u093e\u0930\u093e \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u092d\u0928\u092d\u0928\u093e\u0939\u091f \u092f\u093e \u0917\u0941\u0928\u0917\u0941\u0928\u093e\u0939\u091f<\/strong>\u090f\u0915 \u0938\u094d\u0925\u093f\u0930, \u0927\u0940\u092e\u0940 \u0917\u0941\u0928\u0917\u0941\u0928\u093e\u0939\u091f \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0939\u0948\u0964 \u0924\u0947\u091c \u092f\u093e \u0905\u0928\u093f\u092f\u092e\u093f\u0924 \u0917\u0941\u0928\u0917\u0941\u0928\u093e\u0939\u091f \u0922\u0940\u0932\u0940 \u092a\u0930\u0924\u094b\u0902, \u0915\u094b\u0930 \u0915\u0947 \u0915\u0902\u092a\u0928 \u092f\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0905\u0938\u0902\u0924\u0941\u0932\u0928 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li><li><p><strong>\u091a\u091f\u0916\u0930\u093e\u0939\u091f \u092f\u093e \u092b\u091f\u0915\u093e\u0930<\/strong>\u092f\u0947 \u0927\u094d\u0935\u0928\u093f\u092f\u093e\u0901 \u0905\u0915\u094d\u0938\u0930 \u0906\u0930\u094d\u0915\u093f\u0902\u0917, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947, \u092f\u093e \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0928\u092e\u0940 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p><strong>\u0915\u094d\u0932\u093f\u0915 \u0915\u0930\u0928\u093e \u092f\u093e \u091f\u0948\u092a \u0915\u0930\u0928\u093e<\/strong>: \u092c\u093e\u0930-\u092c\u093e\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u094d\u0932\u093f\u0915 \u0925\u0930\u094d\u092e\u0932 \u0935\u093f\u0938\u094d\u0924\u093e\u0930 \u092f\u093e \u0922\u0940\u0932\u0947 \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p><strong>\u0918\u093f\u0938\u093e\u0908 \u092f\u093e \u091a\u0940\u0916\u0928\u093e<\/strong>\u092f\u0947 \u0906\u0935\u093e\u091c\u093c\u0947\u0902 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902 \u092f\u093e \u092c\u0947\u092f\u0930\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u091b\u0941\u090f \u092c\u093f\u0928\u093e \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u094d\u0935\u0928\u093f\u092f\u094b\u0902 \u0915\u0947 \u0938\u094d\u0930\u094b\u0924 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u0938\u094d\u091f\u0947\u0925\u094b\u0938\u094d\u0915\u094b\u092a \u092f\u093e \u092e\u0948\u0915\u0947\u0928\u093f\u0915 \u0915\u0940 \u0938\u0941\u0928\u0928\u0947 \u0935\u093e\u0932\u0940 \u091b\u0921\u093c\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a \u0915\u094b\u0908 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u094d\u0935\u0928\u093f \u0938\u0941\u0928\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0938\u092e\u092f, \u0905\u0935\u0927\u093f \u0914\u0930 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u0913\u0902 \u0915\u094b \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u092a\u0928\u0947 \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092a\u093f\u091b\u0932\u0947 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0902\u0927\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928<\/h4>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u092a\u0928\u0940 \u0917\u0902\u0927\u0947\u0902\u0926\u094d\u0930\u093f\u092f \u0915\u093e \u092d\u0940 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u090f\u0915 \u0938\u094d\u0935\u0938\u094d\u0925 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0947 \u0924\u0947\u091c \u0917\u0902\u0927 \u0928\u0939\u0940\u0902 \u0906\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0928 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0917\u0902\u0927 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091c\u0932\u093e \u0939\u0941\u0906 \u092f\u093e \u0924\u0940\u0916\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u093f \u0924\u093e\u092a, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0941\u0930\u0902\u0924 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u092f\u093e \u092e\u0940\u0920\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0930\u094d\u0928\u093f\u0936 \u092f\u093e \u0930\u0947\u091c\u093c\u093f\u0928 \u0915\u093e \u0915\u094d\u0937\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0913\u091c\u093c\u094b\u0928 \u092f\u093e \u0927\u093e\u0924\u094d\u0935\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u0930\u094d\u0915\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092c\u093f\u091c\u0932\u0940 \u0915\u093e\u091f\u0947\u0902 \u0914\u0930 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0940\u0932\u0928\u0926\u093e\u0930 \u092f\u093e \u0928\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0915\u093e \u092a\u094d\u0930\u0935\u0947\u0936<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u0940\u0915 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0938\u0941\u0916\u093e\u090f\u0901\u0964<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a \u0907\u0928\u092e\u0947\u0902 \u0938\u0947 \u0915\u094b\u0908 \u092d\u0940 \u0917\u0902\u0927 \u092e\u0939\u0938\u0942\u0938 \u0915\u0930\u0947\u0902 \u0924\u094b \u0924\u0941\u0930\u0902\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0930\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0915\u092d\u0940 \u092d\u0940 \u091c\u0932\u0928\u0947 \u092f\u093e \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0917\u0902\u0927 \u0915\u094b \u0905\u0928\u0926\u0947\u0916\u093e \u0928\u0939\u0940\u0902 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0907\u0938\u0915\u093e \u0905\u0915\u094d\u0938\u0930 \u092e\u0924\u0932\u092c \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092f\u093e \u0935\u093f\u0902\u0921\u093f\u0902\u0917 \u092e\u0947\u0902 \u0915\u094d\u0937\u0924\u093f \u0939\u094b\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092a\u0939\u091a\u093e\u0928 \u0915\u0947 \u091a\u0930\u0923<\/h4>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0926\u0942\u0930\u0940 \u092a\u0930 \u0916\u0921\u093c\u0947 \u0930\u0939\u0947\u0902\u0964.<\/p><\/li><li><p>\u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u092a\u0940\u092a\u0940\u0908 \u092a\u0939\u0928\u0947\u0902, \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0927\u0941\u090f\u0901 \u0915\u0940 \u0906\u0936\u0902\u0915\u093e \u0939\u094b \u0924\u094b \u0930\u0947\u0938\u094d\u092a\u093f\u0930\u0947\u091f\u0930 \u092d\u0940 \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0907\u0915\u093e\u0908 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0918\u0942\u092e\u0947\u0902, \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0913\u0930 \u0930\u0941\u0915\u0915\u0930 \u0938\u0941\u0928\u0947\u0902 \u0914\u0930 \u0938\u0942\u0902\u0918\u0947\u0902\u0964.<\/p><\/li><li><p>\u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937 \u0915\u094b \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0917\u0902\u092d\u0940\u0930 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u0905\u092a\u0928\u0947 \u092a\u0930\u094d\u092f\u0935\u0947\u0915\u094d\u0937\u0915 \u0915\u094b \u0915\u0930\u0947\u0902 \u0914\u0930 \u0906\u0917\u0947 \u0915\u0947 \u0928\u093f\u0926\u093e\u0928 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u090a\u0930\u094d\u091c\u093e \u092f\u0941\u0915\u094d\u0924 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0915\u092d\u0940 \u092d\u0940 \u0906\u0935\u0930\u0923 \u0916\u094b\u0932\u0928\u0947 \u092f\u093e \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u091b\u0942\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0928 \u0915\u0930\u0947\u0902\u0964 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0905\u092a\u0928\u0940 \u0907\u0902\u0926\u094d\u0930\u093f\u092f\u094b\u0902 \u092a\u0930 \u092d\u0930\u094b\u0938\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u094d\u0935\u0928\u093f\u092f\u094b\u0902 \u092f\u093e \u0917\u0902\u0927\u094b\u0902 \u092a\u0930 \u0924\u0941\u0930\u0902\u0924 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u0906\u092a\u0915\u094b \u092e\u0939\u0902\u0917\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0914\u0930 \u0905\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0935\u093f\u0930\u093e\u092e\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u092c\u093f\u091c\u0932\u0940-\u092e\u0941\u0915\u094d\u0924 \u0905\u0935\u0938\u094d\u0925\u093e \u092e\u0947\u0902 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u092b\u093e\u0908<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u092b\u093e\u0908 \u0915\u0947\u0935\u0932 \u0924\u092d\u0940 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f \u091c\u092c \u0906\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930 \u0932\u093f\u092f\u093e \u0939\u094b\u0964 \u092f\u0939 \u0915\u0926\u092e \u0906\u092a\u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0916\u0924\u0930\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0915\u093e\u0930\u094d\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0906\u0935\u0930\u0923 \u0915\u094b \u0916\u094b\u0932\u0915\u0930 \u0938\u092d\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0918\u091f\u0915\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0915\u0947 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u0915\u0942\u0932\u093f\u0902\u0917 \u092a\u0902\u0916\u094b\u0902 \u0914\u0930 \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0938\u0947 \u0927\u0942\u0932 \u0914\u0930 \u0917\u0902\u0926\u0917\u0940 \u0939\u091f\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0932\u0940\u0928\u0930 \u092f\u093e \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e (20 \u0938\u0947 25 psi \u0915\u0947 \u092c\u0940\u091a \u0938\u0947\u091f) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0909\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902 \u091c\u0939\u093e\u0901 \u092e\u0932\u092c\u0947 \u091c\u092e\u093e \u0939\u094b\u0928\u0947 \u0915\u0940 \u0938\u0902\u092d\u093e\u0935\u0928\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u0948\u0938\u0947 \u0915\u094b\u0928\u0947 \u0914\u0930 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u093e\u0928\u0940 \u092f\u093e \u0917\u0940\u0932\u0947 \u0938\u092b\u093e\u0908 \u090f\u091c\u0947\u0902\u091f\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092c\u091a\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0928\u092e\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0902\u091a\u093e \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u091c\u093f\u0926\u094d\u0926\u0940 \u091c\u092e\u093e\u0935 \u092e\u093f\u0932\u0947\u0902, \u0924\u094b \u0909\u0928\u094d\u0939\u0947\u0902 \u090f\u0915 \u0928\u0930\u092e, \u0917\u0948\u0930-\u0927\u093e\u0924\u094d\u0935\u093f\u0915 \u092c\u094d\u0930\u0936 \u0938\u0947 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u092c\u094d\u0930\u0936 \u0915\u0930\u0915\u0947 \u0939\u091f\u093e \u0926\u0947\u0902\u0964 \u0907\u0938 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u094d\u0935\u092f\u0902 \u0915\u094b \u0939\u0935\u093e \u092e\u0947\u0902 \u092e\u094c\u091c\u0942\u0926 \u0915\u0923\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u0936\u094d\u092e\u093e \u0914\u0930 \u0927\u0942\u0932 \u092e\u093e\u0938\u094d\u0915 \u092a\u0939\u0928\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u0927\u0942\u0932 \u0915\u0947 \u091c\u092e\u093e\u0935 \u0915\u094b \u0915\u092e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u091a\u0932\u0947 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092a\u0930 \u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0932\u0917\u093e\u090f\u0901\u0964 \u0909\u091a\u093f\u0924 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0928 \u092b\u093c\u093f\u0932\u094d\u091f\u0930\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092c\u0926\u0932\u0947\u0902\u0964 \u0938\u094d\u0935\u091a\u094d\u091b \u0909\u092a\u0915\u0930\u0923 \u0905\u0927\u093f\u0915 \u0915\u0941\u0936\u0932\u0924\u093e \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u091a\u0932\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0915\u092e \u0938\u0947 \u0915\u092e \u0938\u093e\u0932 \u092e\u0947\u0902 \u090f\u0915 \u092c\u093e\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u092b\u093e\u0908 \u0915\u093e \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902, \u092f\u093e \u0927\u0942\u0932 \u092d\u0930\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0905\u0927\u093f\u0915 \u092c\u093e\u0930\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0938\u0930\u0932 \u0938\u092b\u093e\u0908 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0939\u0948 \u091c\u093f\u0938\u0947 \u0906\u092a \u0905\u092a\u0928\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0936\u0942\u0928\u094d\u092f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0906\u0935\u0930\u0923 \u0916\u094b\u0932\u0947\u0902 \u0914\u0930 \u0927\u0942\u0932 \u092f\u093e \u092e\u0932\u092c\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u0902\u0916\u094b\u0902 \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092f\u093e \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e (20\u201325 \u092a\u0940\u090f\u0938\u0906\u0908) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0928\u0930\u092e \u092c\u094d\u0930\u0936 \u0938\u0947 \u091c\u093f\u0926\u094d\u0926\u0940 \u0917\u0902\u0926\u0917\u0940 \u0915\u094b \u092c\u094d\u0930\u0936 \u0938\u0947 \u0939\u091f\u093e \u0926\u0947\u0902\u0964.<\/p><\/li><li><p>\u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092a\u0930 \u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u092f\u093e \u092c\u0926\u0932\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0938\u0902\u092c\u0928\u094d\u0927\u094b\u0902 \u0915\u094b \u092e\u091c\u092c\u0942\u0924 \u0915\u0930\u0928\u093e<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0924\u094d\u0930 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u092d\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0914\u0930 \u0915\u0938\u0915\u0930 \u0915\u0938\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917, \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0914\u0930 \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0902\u092a\u0928, \u0924\u093e\u092a\u092e\u093e\u0928 \u092e\u0947\u0902 \u092c\u0926\u0932\u093e\u0935 \u0914\u0930 \u092a\u0941\u0930\u093e\u0928\u0947 \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0922\u0940\u0932\u093e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u091f\u0949\u0930\u094d\u0915 \u0930\u0947\u0928\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u092a\u0939\u0941\u0901\u091a \u092f\u094b\u0917\u094d\u092f \u092c\u094b\u0932\u094d\u091f, \u0938\u094d\u0915\u094d\u0930\u0942 \u0914\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0932\u0917\u094d\u0938 \u0915\u094b \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092e\u093e\u0928\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0915\u0938\u0947\u0902\u0964 \u0909\u091a\u094d\u091a-\u0927\u093e\u0930\u093e \u0935\u093e\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902, \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092f\u0947 \u0938\u092c\u0938\u0947 \u0905\u0927\u093f\u0915 \u0922\u0940\u0932\u0947 \u0939\u094b\u0928\u0947 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u0947 \u092f\u093e \u0917\u0930\u094d\u092e\u0940 \u0938\u0947 \u0939\u0941\u090f \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u091c\u094b \u0916\u0930\u093e\u092c \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u092c\u093f\u091c\u0932\u0940 \u0915\u0940 \u0916\u0930\u093e\u092c\u0940 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u092d\u0940 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0940 \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u094b \u0915\u0938\u0928\u093e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u094b \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902 \u091c\u093f\u0938\u0947 \u0906\u092a \u091c\u093e\u0902\u091a\u0924\u0947 \u0914\u0930 \u0915\u0938\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0906\u092a\u0915\u094b \u0906\u0935\u0930\u094d\u0924\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0947 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0907\u0938 \u091a\u0930\u0923 \u0915\u094b \u0915\u092d\u0940 \u0928 \u091b\u094b\u0921\u093c\u0947\u0902\u0964 \u090f\u0915 \u092d\u0940 \u0922\u0940\u0932\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092e\u0939\u0902\u0917\u0940 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u092f\u093e \u0909\u092a\u0915\u0930\u0923 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930\u094d\u0938 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930\u094d\u0938 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/a> \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0915\u094d\u0930\u0964 \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930\u094d\u0938 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0906\u0909\u091f\u092a\u0941\u091f \u0915\u094b \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u094d\u0925\u093f\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u0942\u092e\u093f\u0915\u093e \u0928\u093f\u092d\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925, \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u091c\u0902\u0917 \u0932\u0917 \u0938\u0915\u0924\u0940 \u0939\u0948, \u092f\u093e \u0915\u093e\u0930\u094d\u092c\u0928 \u091c\u092e\u093e \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u092c\u0938\u0947 \u092a\u0939\u0932\u0947 \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u0918\u093f\u0938\u093e\u0935, \u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u0947 \u092f\u093e \u0917\u0921\u094d\u0922\u0947 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964  \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f \u0915\u0947 \u0905\u0902\u0926\u0930 \u0927\u0942\u0932, \u0917\u0902\u0926\u0917\u0940 \u092f\u093e \u0935\u093f\u0926\u0947\u0936\u0940 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964  \u092f\u0926\u093f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092f\u093e \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0938\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964  \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0901\u091a\u093e\u0928\u0947 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0949\u0932\u094d\u0935\u0947\u0902\u091f \u092f\u093e \u0924\u0930\u0932 \u092a\u0926\u093e\u0930\u094d\u0925 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930 \u0915\u094b \u0907\u0938\u0915\u0940 \u092a\u0942\u0930\u0940 \u0938\u0940\u092e\u093e \u092e\u0947\u0902 \u091a\u0932\u093e\u0915\u0930 \u0938\u0941\u091a\u093e\u0930\u0942 \u0917\u0924\u093f \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964  \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u094d\u0935\u0928\u093f, \u091c\u0948\u0938\u0947 \u0918\u093f\u0938\u093e\u0908 \u092f\u093e \u0905\u091f\u0915\u0928\u0947 \u0915\u0940 \u0906\u0935\u093e\u091c\u093c, \u0938\u0941\u0928\u0928\u0947 \u0915\u093e \u0927\u094d\u092f\u093e\u0928 \u0930\u0916\u0947\u0902\u0964  \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092f\u093e \u0905\u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947, \u0924\u094b \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u093e \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930 \u0938\u092e\u0938\u094d\u092f\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0915\u094d\u092f\u093e \u0926\u0947\u0916\u0947\u0902<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0939\u0928\u0947 \u0939\u0941\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f \u0932\u0947\u0902\u0938<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091b\u093f\u0926\u094d\u0930\u0923, \u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902 \u092f\u093e \u092c\u0926\u0932\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u092c\u0928 \u0938\u0902\u091a\u092f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0932\u0947 \u091c\u092e\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0942\u0916\u0940 \u0935\u093f\u0927\u093f\u092f\u094b\u0902 \u0938\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091a\u093f\u092a\u0915\u0928\u093e, \u0916\u0941\u0930\u0926\u0930\u093e \u0906\u0902\u0926\u094b\u0932\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u0930\u0947\u0902 \u092f\u093e \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0922\u0940\u0932\u0947 \u0938\u0902\u092c\u0902\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0940 \u0926\u0930\u093e\u0930\u0947\u0902, \u0927\u0928\u0941\u0937\u093e\u0915\u093e\u0930 \u0928\u093f\u0936\u093e\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u094b \u0915\u0938\u0947\u0902 \u092f\u093e \u092c\u0926\u0932\u0947\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964  \u0905\u0928\u0941\u092a\u092f\u0941\u0915\u094d\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0938\u094d\u0925\u093f\u0930\u0924\u093e \u092f\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930\u094d\u0938 \u0915\u093e \u0909\u091a\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0928\u093f\u0930\u0902\u0924\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0928\u093f\u092f\u092e\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0939\u0930 \u092c\u093e\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u094b \u092c\u093e\u0939\u0930\u0940 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0938\u0947 \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940, \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u092f\u093e \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0936\u0942\u0928\u094d\u092f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0906\u0935\u0930\u0923 \u0915\u094b \u0916\u094b\u0932\u0915\u0930 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u0938\u092d\u0940 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921\u094b\u0902 \u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u0930\u0942\u092a \u0938\u0947 \u0926\u0947\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u091c\u0902\u0917, \u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u093e \u092f\u093e \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923 \u0926\u0947\u0916\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u091f\u0942\u091f\u0947 \u0939\u0941\u090f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u092d\u0940 \u091c\u093e\u0902\u091a\u0928\u0947 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0902 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 \u0935\u094d\u092f\u093e\u092a\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>\u0938\u092d\u0940 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0914\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u093e \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/strong><\/p><\/li><li><p><strong>\u0915\u093f\u0938\u0940 \u092d\u0940 \u0922\u0940\u0932\u0947 \u0938\u094d\u0915\u094d\u0930\u0942 \u092f\u093e \u092c\u094b\u0932\u094d\u091f \u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0909\u092a\u0915\u0930\u0923 \u0938\u0947 \u0915\u0938\u0947\u0902\u0964.<\/strong><\/p><\/li><li><p><strong>\u0927\u093e\u0924\u0941 \u0915\u0947 \u0939\u093f\u0938\u094d\u0938\u094b\u0902 \u092a\u0930 \u091c\u0902\u0917 \u092f\u093e \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/strong><\/p><\/li><li><p><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092f\u093e \u0938\u0942\u0916\u0940 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0927\u0942\u0932 \u0914\u0930 \u092e\u0932\u092c\u0947 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964.<\/strong><\/p><\/li><li><p><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902, \u091a\u093f\u092a\u094d\u0938 \u092f\u093e \u0930\u0902\u0917 \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964.<\/strong><\/p><\/li><li><p><strong>\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924\u094b\u0902, \u091c\u0948\u0938\u0947 \u0915\u093f \u0915\u093e\u0932\u0947 \u0927\u092c\u094d\u092c\u0947 \u092f\u093e \u092a\u093f\u0918\u0932\u0947 \u0939\u0941\u090f \u0927\u092c\u094d\u092c\u0947, \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/strong><\/p><\/li><li><p><strong>\u092f\u0939 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u092d\u0940 \u092a\u0939\u091a\u093e\u0928 \u0932\u0947\u092c\u0932 \u0938\u094d\u092a\u0937\u094d\u091f \u0914\u0930 \u092a\u0920\u0928\u0940\u092f \u0939\u0948\u0902\u0964.<\/strong><\/p><\/li>\n<\/ol>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0926\u0930\u094d\u091c \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0915\u094b\u0908 \u0915\u094d\u0937\u0924\u093f \u092e\u093f\u0932\u0947 \u0924\u094b \u0924\u0938\u094d\u0935\u0940\u0930\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u092e\u0938\u094d\u092f\u093e \u092a\u093e\u0908 \u0917\u0908<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0907\u0938\u0915\u093e \u0915\u094d\u092f\u093e \u092e\u0924\u0932\u092c \u0939\u0948<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0922\u0940\u0932\u0947 \u0938\u0902\u092c\u0902\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947\/\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u093e \u0916\u0924\u0930\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0941\u0930\u0902\u0924 \u0915\u0938\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u092f\u093e \u091c\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u0930\u093e\u092c \u091a\u093e\u0932\u0915\u0924\u093e, \u0935\u093f\u092b\u0932\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0941\u0930\u094d\u091c\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902 \u092f\u093e \u092c\u0926\u0932\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u0942\u091f\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u092c\u0926\u0932\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e\/\u091c\u0932\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u093f \u0924\u093e\u092a, \u0906\u0930\u094d\u0915\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902 \u0914\u0930 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0927\u0942\u0932\/\u092e\u0932\u092c\u0947 \u0915\u093e \u091c\u092e\u093e\u0935<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917, \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0917\u0902\u092d\u0940\u0930 \u0915\u094d\u0937\u0924\u093f \u092e\u093f\u0932\u0947, \u0924\u094b \u092e\u0930\u092e\u094d\u092e\u0924 \u092a\u0942\u0930\u0940 \u0939\u094b\u0928\u0947 \u0924\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u092a\u0941\u0928\u0903 \u090a\u0930\u094d\u091c\u093e-\u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0928 \u0915\u0930\u0947\u0902\u0964 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921 \u0915\u0947 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u0938\u092b\u093e\u0908 \u0914\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921\u094b\u0902 \u092a\u0930 \u0915\u092d\u0940 \u092d\u0940 \u092a\u093e\u0928\u0940 \u092f\u093e \u0917\u0940\u0932\u0947 \u0938\u092b\u093e\u0908 \u090f\u091c\u0947\u0902\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928 \u0915\u0930\u0947\u0902\u0964 \u0928\u092e\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u0902\u092c\u0902\u0927\u0940 \u0916\u0924\u0930\u094b\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0939\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0915\u094d\u0930 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094b\u0930\u094d\u0921\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0915\u0947 \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u0930\u0902\u0924\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u091b\u094b\u091f\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u092c\u0921\u093c\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u092e\u0947\u0902 \u092c\u0926\u0932\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0915\u0921\u093c\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0914\u0930 \u0926\u094b\u0937<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0939\u0930 \u092c\u093e\u0930 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935<\/a> \u0938\u0924\u094d\u0930\u0964 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u093e \u0938\u092c\u0938\u0947 \u0906\u092e \u0914\u0930 \u0916\u0924\u0930\u0928\u093e\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u092e\u0947\u0902 \u0938\u0947 \u090f\u0915 \u0939\u0948\u0964 \u092f\u0939 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0902\u091a\u093e \u0938\u0915\u0924\u093e \u0939\u0948, \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u094b \u0935\u093f\u0915\u0943\u0924 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948, \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928 \u0915\u094b \u0915\u092e \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e, \u091c\u0932\u0928\u0947 \u0915\u0940 \u0917\u0902\u0927, \u092f\u093e \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u092a\u093f\u0918\u0932\u093e \u0939\u0941\u0906 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092d\u0940 \u0926\u0947\u0916 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0938\u094d\u092a\u0937\u094d\u091f \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0915\u093e\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092e\u0947\u0902 \u0930\u0941\u0915\u093e\u0935\u091f, \u0905\u0927\u093f\u0915 \u092d\u093e\u0930 \u0935\u093e\u0932\u0947 \u0938\u0930\u094d\u0915\u093f\u091f \u0914\u0930 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a \u0907\u0928\u092e\u0947\u0902 \u0938\u0947 \u0915\u094b\u0908 \u092d\u0940 \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0916\u0947\u0902 \u0924\u094b \u0924\u0941\u0930\u0902\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0930\u0947\u0902\u0964 \u0917\u0930\u094d\u092e \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u0947\u0902\u0938\u0930 \u092f\u093e \u0907\u0928\u094d\u092b\u094d\u0930\u093e\u0930\u0947\u0921 \u0915\u0948\u092e\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0905\u092a\u0928\u0940 \u092e\u093e\u092a \u0915\u094b \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0938\u0940\u092e\u093e\u0913\u0902 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0947 \u0905\u0927\u093f\u0915 \u092a\u093e\u092f\u093e \u091c\u093e\u090f \u0924\u094b \u092d\u093e\u0930 \u0915\u092e \u0915\u0930\u0947\u0902 \u0914\u0930 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0924\u0941\u0930\u0902\u0924 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0938\u0947 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u0914\u0930 \u092e\u0939\u0902\u0917\u0940 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u091a\u0932\u0924\u0947 \u0939\u0940 \u0909\u0928\u094d\u0939\u0947\u0902 \u0924\u0941\u0930\u0902\u0924 \u0938\u0902\u092c\u094b\u0927\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0928\u092e\u0940 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923<\/h3>\n\n\n\n<p>\u0928\u092e\u0940 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u091a\u0941\u092a\u091a\u093e\u092a \u0926\u0941\u0936\u094d\u092e\u0928 \u0939\u0948\u0964 \u0925\u094b\u0921\u093c\u0940 \u0938\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u092d\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u091f\u0942\u091f\u0928\u0947 \u0914\u0930 \u0935\u093f\u092b\u0932 \u0939\u094b\u0928\u0947 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0939\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u092e\u0940 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0927\u093e\u0924\u0941 \u0915\u0947 \u0939\u093f\u0938\u094d\u0938\u094b\u0902 \u092a\u0930 \u0938\u0902\u0918\u0928\u0928, \u092a\u093e\u0928\u0940 \u0915\u0947 \u0926\u093e\u0917 \u092f\u093e \u091c\u0902\u0917 \u0926\u0947\u0916\u0947\u0902\u0964 \u0928\u092e\u0940 \u0930\u093f\u0938\u093e\u0935, \u0916\u0930\u093e\u092c \u0938\u0940\u0932 \u092f\u093e \u0905\u0928\u0941\u091a\u093f\u0924 \u092d\u0902\u0921\u093e\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0928\u092e\u0940 \u0915\u0940 \u0909\u092a\u0938\u094d\u0925\u093f\u0924\u093f \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092c\u093e\u0930 \u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u0926\u094b\u0917\u0941\u0928\u0940 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0907\u0938\u0915\u0940 \u0906\u092f\u0941 \u0906\u0927\u0940 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0915\u093e\u0917\u091c\u093c\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u093e\u0928\u0940 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u0938\u094b\u0916 \u0932\u0947\u0924\u093e \u0939\u0948 \u0914\u0930 \u0917\u0940\u0932\u093e \u0939\u094b\u0928\u0947 \u092a\u0930 \u092c\u0939\u0941\u0924 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0915\u094d\u0937\u092f\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925, \u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u092a\u094d\u0930\u0924\u093f \u0935\u0930\u094d\u0937 0.1% \u0938\u0947 0.2% \u0924\u0915 \u092c\u0922\u093c \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u092a\u0941\u0930\u093e\u0928\u0947 \u092f\u093e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0928\u092e\u0940 \u0915\u093e \u0938\u094d\u0924\u0930 4% \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948, \u091c\u094b \u092c\u0939\u0941\u0924 \u0916\u0924\u0930\u0928\u093e\u0915 \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u0915\u094d\u0937\u094d\u092f \u0935\u093f\u0935\u0930\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094d\u0938 \u092a\u0930 \u092a\u094d\u0930\u092d\u093e\u0935<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u0947 \u0915\u0940 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u094b \u0924\u0947\u091c \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u0917\u091c\u093c\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902\u0964.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u090a\u0937\u094d\u092e\u0940\u092f \u0914\u0930 \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u0940 \u0939\u0948\u0964.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u092c\u0922\u093c\u0924\u0940 \u0939\u0948\u0964.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0941\u0930\u093e\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0905\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u094d\u0924\u0930 \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0915\u0940 \u0909\u092a\u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0909\u091a\u094d\u091a \u0924\u093e\u092a\u092e\u093e\u0928\u0964.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u0947 \u0915\u0940 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u094b \u0914\u0930 \u092d\u0940 \u0924\u0947\u091c\u093c \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0942\u0916\u093e \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0938\u0940\u0932 \u0914\u0930 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0915\u0940 \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0928\u092e\u0940 \u092e\u093f\u0932\u0947, \u0924\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0916\u093e\u090f\u0901 \u0914\u0930 \u0930\u093f\u0938\u093e\u0935 \u0915\u0947 \u0938\u094d\u0930\u094b\u0924 \u0915\u094b \u0920\u0940\u0915 \u0915\u0930\u0947\u0902, \u092b\u093f\u0930 \u0939\u0940 \u0907\u0938\u0947 \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0935\u093e\u092a\u0938 \u0932\u093e\u090f\u0901\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f<\/h3>\n\n\n\n<p>\u0938\u094d\u0925\u093e\u092a\u0928\u093e, \u0930\u0916\u0930\u0916\u093e\u0935 \u092f\u093e \u092c\u093e\u0939\u0930\u0940 \u092a\u094d\u0930\u092d\u093e\u0935\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u092c\u0949\u0921\u0940 \u0914\u0930 \u0906\u0935\u0930\u0923 \u092a\u0930 \u0921\u0947\u0902\u091f, \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u091f\u0942\u091f\u0947 \u0939\u0941\u090f \u0939\u093f\u0938\u094d\u0938\u0947 \u0926\u0947\u0916\u0928\u0947 \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0915\u0942\u0932\u093f\u0902\u0917 \u092b\u0948\u0928, \u092e\u0941\u0921\u093c\u0940 \u0939\u0941\u0908 \u0917\u094d\u0930\u093f\u0932 \u092f\u093e \u0922\u0940\u0932\u0947 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0938\u092d\u0940 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0905\u0915\u094d\u0938\u0930 \u0905\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u0928\u094d\u092e \u0926\u0947\u0924\u0940 \u0939\u0948, \u091c\u0948\u0938\u0947 \u0915\u093f \u0916\u0930\u093e\u092c \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092f\u093e \u0916\u0941\u0932\u0940 \u0939\u0941\u0908 \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938\u0964 \u0906\u092a \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u0947 \u092a\u093e\u0938 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924 \u092f\u093e \u092a\u093f\u0918\u0932\u0947 \u0939\u0941\u090f \u0927\u092c\u094d\u092c\u0947 \u092d\u0940 \u0926\u0947\u0916 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u092d\u094c\u0924\u093f\u0915 \u0926\u094b\u0937 \u092e\u093f\u0932\u0947\u0902, \u0924\u094b \u0909\u0928\u094d\u0939\u0947\u0902 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u092e\u0947\u0902 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902 \u0914\u0930 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u092d\u093e\u0917\u094b\u0902 \u0915\u0940 \u0924\u0941\u0930\u0902\u0924 \u092e\u0930\u092e\u094d\u092e\u0924 \u092f\u093e \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u0915\u0941\u091b \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u091a\u0941\u0928\u094c\u0924\u093f\u092f\u093e\u0901 \u0914\u0930 \u0909\u0928\u0915\u0947 \u0938\u092e\u093e\u0927\u093e\u0928 \u0926\u093f\u090f \u0917\u090f \u0939\u0948\u0902 \u091c\u093f\u0928\u0915\u093e \u0906\u092a \u0938\u093e\u092e\u0928\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u091a\u0941\u0928\u094c\u0924\u0940<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u092e\u093e\u0927\u093e\u0928<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0941\u0930\u093e\u0928\u093e \u092c\u0941\u0928\u093f\u092f\u093e\u0926\u0940 \u0922\u093e\u0902\u091a\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0918\u093f\u0938\u0928\u0947 \u0914\u0930 \u091f\u0942\u091f-\u092b\u0942\u091f \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0913\u0935\u0930\u0932\u094b\u0921\u093f\u0902\u0917 \u0914\u0930 \u091a\u0930\u092e \u092e\u093e\u0902\u0917\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u093f\u092d\u093e\u0930 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0932\u094b\u0921 \u0938\u094d\u0924\u0930\u094b\u0902 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u0915\u094d\u0937\u0930\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0915\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0940\u0924\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0940\u0924\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u094b \u0905\u0915\u094d\u0938\u0930 \u0938\u093e\u092b \u0915\u0930\u0947\u0902 \u0914\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 \u0914\u0930 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u092e\u093e\u0930\u094d\u091f \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u092a\u0930\u093f\u0935\u0939\u0928 \u0914\u0930 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0938\u0902\u092d\u093e\u0932\u0947\u0902\u0964 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0915\u094d\u0937\u0924\u093f \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0907\u0928 \u092c\u093e\u0924\u094b\u0902 \u0915\u093e \u0927\u094d\u092f\u093e\u0928 \u0930\u0916\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901<\/a> \u0939\u0930 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0926\u093f\u0928\u091a\u0930\u094d\u092f\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0924\u094d\u0930 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u092a\u0930 \u092c\u093e\u0930\u0940\u0915\u0940 \u0938\u0947 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0909\u0928\u0915\u0947 \u0909\u091a\u093f\u0924 \u092e\u093e\u0930\u094d\u0917\u094b\u0902 \u092e\u0947\u0902 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948 \u0914\u0930 \u0916\u0924\u0930\u0928\u093e\u0915 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964 \u091c\u092c \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0906\u092a\u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f, \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0914\u0930 \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0906\u092a \u0907\u0928 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u0926\u0947\u0916\u0915\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u0924\u0939\u094b\u0902 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u092b\u091f\u093e\u0935<\/p><\/li><li><p>\u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u092d\u0942\u0930\u0947 \u092f\u093e \u0915\u093e\u0932\u0947 \u0927\u092c\u094d\u092c\u0947<\/p><\/li><li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u091a\u0942\u0928\u0947 \u091c\u0948\u0938\u093e \u092f\u093e \u092a\u093e\u0909\u0921\u0930 \u091c\u0948\u0938\u093e \u0905\u0935\u0936\u0947\u0937<\/p><\/li><li><p>\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0902\u0927\u0947\u0902, \u091c\u0948\u0938\u0947 \u091c\u0932\u0928\u0947 \u092f\u093e \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0917\u0902\u0927\u0947\u0902<\/p><\/li><li><p>\u0938\u0941\u0928\u0928\u0947 \u092e\u0947\u0902 \u0906\u0928\u0947 \u0935\u093e\u0932\u0940 \u091a\u0930\u094d\u0930-\u091a\u0930\u094d\u0930 \u092f\u093e \u092b\u091f-\u092b\u091f \u0915\u0940 \u0906\u0935\u093e\u091c\u093c\u0947\u0902<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u091b\u094b\u091f\u0940 \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e \u092d\u0940 \u0917\u0902\u092d\u0940\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0907\u0928 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u0915\u092d\u0940 \u092d\u0940 \u0905\u0928\u0926\u0947\u0916\u093e \u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u092d\u0940 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u094b\u0928\u094b\u0902, \u0915\u093f\u0928\u093e\u0930\u094b\u0902 \u0914\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u0947 \u092a\u093e\u0938 \u0915\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0915\u094d\u0937\u0924\u093f \u0926\u093f\u0916\u093e\u0908 \u0926\u0947, \u0924\u094b \u0909\u0938\u0947 \u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902 \u0914\u0930 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0947 \u0938\u0902\u0926\u0930\u094d\u092d \u0915\u0947 \u0932\u093f\u090f \u0924\u0938\u094d\u0935\u0940\u0930\u0947\u0902 \u0932\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0928\u092e\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u090f\u0915 \u092c\u0921\u093c\u0940 \u0926\u0941\u0936\u094d\u092e\u0928 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0939\u0930 \u0938\u092e\u092f \u0938\u0942\u0916\u093e \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0928\u092e\u0940 \u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0935\u0939 \u091c\u0932\u094d\u0926\u0940 \u0916\u0930\u093e\u092c \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u092a\u093e\u0938 \u0938\u0902\u0918\u0928\u0928, \u092a\u093e\u0928\u0940 \u0915\u0947 \u0926\u093e\u0917 \u092f\u093e \u091c\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0928\u092e\u0940 \u092e\u093f\u0932\u0947, \u0924\u094b \u0909\u0938 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0938\u0941\u0916\u093e\u090f\u0902 \u0914\u0930 \u0930\u093f\u0938\u093e\u0935 \u0915\u0947 \u0938\u094d\u0930\u094b\u0924 \u0915\u094b \u0920\u0940\u0915 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0906\u092a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0905\u0935\u0936\u094b\u0937\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0915\u092e\u091c\u094b\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0905\u092a\u0928\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092e\u093e\u0928\u094b\u0902 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u094d\u0924\u0930 \u0938\u0947 \u0928\u0940\u091a\u0947 \u0906 \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0924\u0941\u0930\u0902\u0924 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0939\u0948 \u091c\u094b \u0906\u092a\u0915\u094b \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0914\u0930 \u0909\u0928\u0915\u0947 \u0938\u092e\u093e\u0927\u093e\u0928\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0947\u0917\u0940:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091c\u094b \u0906\u092a \u0926\u0947\u0916\u0924\u0947 \u092f\u093e \u0938\u0941\u0928\u0924\u0947 \u0939\u0948\u0902<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u092a\u0915\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u092b\u091f\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0938\u094d\u092a\u0937\u094d\u091f \u0926\u0930\u093e\u0930\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092c\u0926\u0932\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092d\u0942\u0930\u0947 \u092f\u093e \u0915\u093e\u0932\u0947 \u0927\u092c\u094d\u092c\u0947<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091a\u0942\u0928\u0947 \u091c\u0948\u0938\u093e \u0905\u0935\u0936\u0947\u0937<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u093e\u0909\u0921\u0930 \u091c\u0948\u0938\u0947 \u091c\u092e\u093e\u0935<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902 \u0914\u0930 \u0928\u092e\u0940 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091c\u0932\u0928\u0947 \u0915\u0940 \u0917\u0902\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0947\u091c\u093c \u092f\u093e \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0917\u0902\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0902\u091a\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0930\u0940\u0921\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u0940\u0915\u094d\u0937\u093e \u092a\u0930\u093f\u0923\u093e\u092e \u092e\u093e\u0928\u0915 \u0938\u0947 \u0928\u0940\u091a\u0947<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0924\u094d\u0915\u093e\u0932 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u0930 \u092a\u093e\u0928\u0940 \u092f\u093e \u0917\u0940\u0932\u0947 \u0938\u092b\u093e\u0908 \u090f\u091c\u0947\u0902\u091f\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092c\u091a\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0947\u0935\u0932 \u0938\u0942\u0916\u0940 \u0935\u093f\u0927\u093f\u092f\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902, \u091c\u0948\u0938\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e\u093f\u0902\u0917 \u092f\u093e \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0939\u0935\u093e\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0938\u092b\u093e\u0908 \u0915\u0947 \u0932\u093f\u090f \u0930\u0938\u093e\u092f\u0928\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u0947, \u0924\u094b \u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0905\u092a\u0928\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u091f\u0940\u092e \u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u092e\u0939\u0902\u0917\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u091a\u093e\u0932\u0942 \u0930\u0916\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0938\u0902\u092c\u094b\u0927\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0905\u092a\u0928\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0909\u091a\u093f\u0924 \u0938\u092b\u093e\u0908 \u0906\u092a\u0915\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fabb19f1816d48c4913405051325f8e9.webp\" alt=\"\u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\" class=\"wp-image-1582\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fabb19f1816d48c4913405051325f8e9.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fabb19f1816d48c4913405051325f8e9-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fabb19f1816d48c4913405051325f8e9-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fabb19f1816d48c4913405051325f8e9-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fabb19f1816d48c4913405051325f8e9-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u091b\u0935\u093f \u0938\u094d\u0930\u094b\u0924: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">\u092a\u0947\u0915\u094d\u0938\u0932\u094d\u0938<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0914\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/a>. \u0906\u092a\u0915\u094b \u0907\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0924\u093e\u0915\u093f \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u091a\u0932 \u0938\u0915\u0947 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u092c\u0928\u093e \u0930\u0939\u0947\u0964 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915 \u0938\u0942\u0916\u0940 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u0908 \u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092c\u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0928\u0941\u092a\u093e\u0924, \u0927\u094d\u0930\u0941\u0935\u0940\u092f\u0924\u093e, \u0928\u094b-\u0932\u094b\u0921 \u0939\u093e\u0928\u093f, \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f, \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915, \u0932\u093e\u0917\u0942 \u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0935\u093f\u092d\u0935, \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928, \u091a\u0941\u0902\u092c\u0928 \u0927\u093e\u0930\u093e, \u092a\u093e\u0935\u0930 \u092b\u0948\u0915\u094d\u091f\u0930, \u092b\u0947\u091c \u0938\u0902\u092c\u0902\u0927 \u0914\u0930 \u0927\u094d\u0935\u0928\u093f \u0938\u094d\u0924\u0930 \u092e\u093e\u092a\u0928 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0906\u092a \u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u092f\u0939 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0905\u0928\u0941\u092a\u093e\u0924 \u0938\u0939\u0940 \u0939\u0948\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091c\u093e\u0902\u091a\u0924\u093e \u0939\u0948 \u0915\u093f \u092a\u094d\u0930\u093e\u0907\u092e\u0930\u0940 \u0914\u0930 \u0938\u0947\u0915\u0947\u0902\u0921\u0930\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u092c\u0940\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0928\u0941\u092a\u093e\u0924 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0924\u093e \u0939\u0948 \u092f\u093e \u0928\u0939\u0940\u0902\u0964 \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0938\u0947 \u090f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947\u091f \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u090f\u0915 \u091c\u094d\u091e\u093e\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0909\u092a\u0915\u0930\u0923 \u0906\u0909\u091f\u092a\u0941\u091f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u092e\u093e\u092a\u0924\u093e \u0939\u0948 \u0914\u0930 \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u0905\u0928\u0941\u092a\u093e\u0924 \u0905\u092a\u0947\u0915\u094d\u0937\u093f\u0924 \u092e\u093e\u0928 \u0938\u0947 \u0935\u093f\u091a\u0932\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948, \u0924\u094b \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092e\u0947\u0902 \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0917\u0932\u0924 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u092f\u093e \u0905\u091a\u093e\u0928\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0909\u0928\u094d\u0939\u0947\u0902 \u092a\u093f\u091b\u0932\u0940 \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0938\u0939\u0940 \u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0906\u092a\u0915\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0938\u0939\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0964 \u0906\u092a\u0915\u094b \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u092c\u093e\u0926, \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u0914\u0930 \u091c\u092c \u092d\u0940 \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0938\u092e\u0938\u094d\u092f\u093e \u0938\u0902\u0926\u0947\u0939 \u0939\u094b, \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0905\u0935\u0936\u094b\u0937\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0905\u0935\u0936\u094b\u0937\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0921\u0940\u0938\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u094d\u0935\u0938\u094d\u0925 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0930\u0939\u0928\u0947 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u0947\u0902 \u0928\u093f\u0930\u0902\u0924\u0930 \u0935\u0943\u0926\u094d\u0927\u093f \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964 \u0915\u092e \u092f\u093e \u0905\u0938\u094d\u0925\u093f\u0930 \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938 \u0928\u092e\u0940, \u0938\u0902\u0926\u0942\u0937\u0923, \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u092f\u0939 \u0915\u094d\u092f\u093e \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u091a\u094d\u091b\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u091c\u093e\u0930\u0940 \u0930\u0916\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0942\u0916\u093e \u0914\u0930 \u0938\u093e\u092b\u093c \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0938\u094d\u0925\u093f\u0930 \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092f\u093e \u0915\u093f\u0938\u0940 \u092d\u0940 \u0910\u0938\u0940 \u0918\u091f\u0928\u093e \u0915\u0947 \u092c\u093e\u0926 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u091c\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948, \u091c\u0948\u0938\u0947 \u092a\u093e\u0928\u0940 \u0915\u093e \u092a\u094d\u0930\u0935\u0947\u0936 \u092f\u093e \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940\u0964 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0935\u093f\u0915\u0943\u0924 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/h3>\n\n\n\n<p>\u0906\u092a \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902 \u0924\u093e\u0915\u093f \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u091a\u093e\u0932\u0915 \u092f\u093e \u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u091f\u0930\u094d\u0928 \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u091a\u0932 \u0938\u0915\u0947\u0964 \u0906\u092a \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0915\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u091c\u093e\u0902\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093f\u091f\u0932 \u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0905\u092a\u0928\u0947 \u092e\u093e\u092a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b \u0930\u0939\u0947 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0909\u091a\u094d\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u093e \u0905\u0915\u094d\u0938\u0930 \u092e\u0924\u0932\u092c \u0922\u0940\u0932\u0947 \u092f\u093e \u091c\u0902\u0917 \u0932\u0917\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>\u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u0915\u0941\u0902\u0921\u0932 \u092f\u093e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0947 \u092c\u093e\u0926, \u0914\u0930 \u0905\u092a\u0928\u0940 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u093f\u0928\u091a\u0930\u094d\u092f\u093e \u0915\u0947 \u0939\u093f\u0938\u094d\u0938\u0947 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0906\u092a\u0915\u094b \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u092a\u0928\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u092e\u0947\u0902 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092e\u093e\u0928 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0915\u0941\u0936\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093e\u0924\u094d\u092e\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u092e\u0942\u0932\u094d\u092f\u0935\u093e\u0928 \u0921\u0947\u091f\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u091c\u0932\u094d\u0926\u0940 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u0930\u0902\u0924\u0930 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0906\u092a\u0915\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u093f\u0938\u0902\u092a\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0926\u0940\u0930\u094d\u0918\u093e\u092f\u0941 \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0915\u094b\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u091f\u0947\u0938\u094d\u091f<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u094b\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u091f\u0947\u0938\u094d\u091f \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u0939 \u091c\u093e\u0902\u091a\u0924\u093e \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b\u0930 \u0915\u093e \u090f\u0915\u0932, \u0920\u094b\u0938 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0939\u0948 \u092f\u093e \u0928\u0939\u0940\u0902\u0964 \u090f\u0915 \u0909\u091a\u093f\u0924 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0916\u0924\u0930\u0928\u093e\u0915 \u092a\u0930\u093f\u0938\u0902\u091a\u093e\u0930\u0940 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u0908 \u092f\u093e \u092b\u094d\u0932\u094b\u091f\u093f\u0902\u0917 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092e\u093f\u0932\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917, \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0936\u094b\u0930, \u092f\u093e \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u092a\u0921\u093c \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092e\u0941\u0916\u094d\u092f \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0936\u0942\u0928\u094d\u092f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0915\u094b\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u090f\u0901, \u091c\u094b \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0915\u094b\u0930 \u092b\u094d\u0930\u0947\u092e \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u092a\u093e\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0915\u094b\u0930 \u0914\u0930 \u0905\u0930\u094d\u0925 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0947 \u092c\u0940\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093f\u091f\u0932 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0947\u0902\u0938 \u091f\u0947\u0938\u094d\u091f\u0930 (\u092e\u0947\u0917\u093e\u0913\u092e\u0940\u091f\u0930) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u0928 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u090f\u0915 \u0938\u094d\u0935\u0938\u094d\u0925 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092e\u0947\u0902 \u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0926\u093f\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 1 \u0913\u092e \u0938\u0947 \u0915\u092e\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0909\u091a\u094d\u091a \u092f\u093e \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u0935\u093e\u0932\u0940 \u0930\u0940\u0921\u093f\u0902\u0917 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947, \u0924\u094b \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 \u0915\u093f \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0938\u094d\u091f\u094d\u0930\u0948\u092a \u091f\u0942\u091f \u0917\u092f\u093e \u0939\u094b \u092f\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0922\u0940\u0932\u093e \u0939\u094b\u0964 \u092f\u0926\u093f \u0906\u092a \u090f\u0915 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092a\u0925 \u092a\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0924\u093e\u0930\u094b\u0902 \u0915\u0940 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0924\u0941\u0930\u0902\u0924 \u0920\u0940\u0915 \u0915\u0930\u0928\u0940 \u0939\u094b\u0917\u0940\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0905\u092a\u0928\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092e\u0947\u0902 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u0906\u092a\u0915\u0947 \u0915\u094b\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0935\u094d\u092f\u093e\u0916\u094d\u092f\u093e \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0924\u094d\u0935\u0930\u093f\u0924 \u0938\u0902\u0926\u0930\u094d\u092d \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u0940 \u0917\u0908 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0907\u0938\u0915\u093e \u0915\u094d\u092f\u093e \u092e\u0924\u0932\u092c \u0939\u0948<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0906\u0935\u0936\u094d\u092f\u0915<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>1 \u0913\u092e \u0938\u0947 \u0915\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u093f\u0924 \u0915\u094b\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u094b\u0908 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0906\u0935\u0936\u094d\u092f\u0915 \u0928\u0939\u0940\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>1 \u0913\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u0930\u093e\u092c \u092f\u093e \u091f\u0942\u091f\u0940 \u0939\u0941\u0908 \u091c\u093c\u092e\u0940\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091c\u092e\u0940\u0928 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u0935\u093e\u0932\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0908 \u092f\u093e \u0922\u0940\u0932\u0940 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0939\u0940 \u0935\u093e\u092f\u0930\u093f\u0902\u0917, \u092b\u093f\u0930 \u0938\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092f\u093e \u0915\u093f\u0938\u0940 \u092d\u0940 \u092c\u0921\u093c\u0947 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0947 \u092c\u093e\u0926 \u0915\u094b\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u0938\u0930\u0932 \u091c\u093e\u0902\u091a \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0914\u0930 \u0906\u092a\u0915\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0916\u0924\u0930\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u0947\u0939\u0924 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 (PD) \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u090f\u0915 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091a\u093f\u0902\u0917\u093e\u0930\u0940 \u0939\u0948 \u091c\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0915\u092e\u091c\u094b\u0930 \u092f\u093e \u0915\u094d\u0937\u0940\u0923 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0909\u0938\u0915\u0947 \u092d\u0940\u0924\u0930 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925, PD \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0915\u094d\u0937\u0940\u0923 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0916\u0924\u0930\u0928\u093e\u0915 \u0926\u094b\u0937 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0906\u092a \u0935\u093f\u0936\u0947\u0937 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0909\u092a\u0915\u0930\u0923 PD \u0917\u0924\u093f\u0935\u093f\u0927\u093f \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u092f\u093e \u0905\u0932\u094d\u091f\u094d\u0930\u093e\u0938\u094b\u0928\u093f\u0915 \u0936\u094b\u0930 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 PD \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u092f\u0926\u093f \u0906\u092a\u0915\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0920\u094b\u0930 \u092f\u093e \u0906\u0930\u094d\u0926\u094d\u0930 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u092a\u093e\u0938 \u091a\u0930\u094d\u0930-\u091a\u0930\u094d\u0930 \u092f\u093e \u092b\u0941\u0938\u092b\u0941\u0938\u093e\u0939\u091f \u091c\u0948\u0938\u0940 \u0906\u0935\u093e\u091c\u0947\u0902<\/p><\/li><li><p>\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0902\u0927\u0947\u0902, \u091c\u0948\u0938\u0947 \u0913\u091c\u093c\u094b\u0928 \u092f\u093e \u091c\u0932\u0928\u0947 \u0915\u0940 \u0917\u0902\u0927<\/p><\/li><li><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u0924\u0939\u094b\u0902 \u092a\u0930 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u093f\u0936\u093e\u0928 \u092f\u093e \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u0915\u092d\u0940 \u092d\u0940 \u0905\u0928\u0926\u0947\u0916\u093e \u0928 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u0925\u094b\u0921\u093c\u0940 \u0938\u0940 PD \u0917\u0924\u093f\u0935\u093f\u0927\u093f \u092d\u0940 \u0924\u0947\u091c\u0940 \u0938\u0947 \u092c\u0922\u093c \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u092c\u0921\u093c\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u092f\u0926\u093f \u0938\u0902\u092d\u0935 \u0939\u094b \u0924\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u0940\u0921\u0940 \u0921\u093f\u091f\u0947\u0915\u094d\u091f\u0930 \u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u0947 \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0938\u092d\u0940 \u0938\u0941\u0932\u092d \u0938\u0924\u0939\u094b\u0902 \u0915\u094b \u092a\u0940\u0921\u0940 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0915\u0948\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0915\u093f\u0938\u0940 \u092d\u0940 \u092a\u0924\u093e \u0932\u0917\u0940 \u0917\u0924\u093f\u0935\u093f\u0927\u093f \u0915\u093e \u0938\u094d\u0925\u093e\u0928 \u0914\u0930 \u0924\u0940\u0935\u094d\u0930\u0924\u093e \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b PD \u092e\u093f\u0932\u0924\u093e \u0939\u0948, \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u093e\u0930\u0923 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0947\u0902, \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0947\u0902, \u092f\u093e \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0928\u0941\u0938\u093e\u0930 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u092c\u0926\u0932\u0947\u0902\u0964 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0914\u0930 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908\u092f\u094b\u0902 \u0915\u093e \u0938\u093e\u0930\u093e\u0902\u0936 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u0940\u0921\u0940 \u0938\u0902\u0915\u0947\u0924\u0915<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u092a\u0915\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0928\u0928\u0947 \u092f\u094b\u0917\u094d\u092f \u091a\u0930\u094d\u0930-\u091a\u0930\u094d\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0913\u091c\u093c\u094b\u0928 \u0915\u0940 \u0917\u0902\u0927<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0924\u0939\u0940 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u092b\u093e\u0908 \u0914\u0930 \u092e\u0930\u092e\u094d\u092e\u0924<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0907\u0938\u0915\u0940 \u0938\u0947\u0935\u093e \u0905\u0935\u0927\u093f \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u0906\u092a\u0915\u094b \u092e\u0939\u0902\u0917\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0914\u0930 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u091f\u094c\u0924\u0940 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0928\u093f\u0935\u093e\u0930\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u093e \u0938\u092e\u092f-\u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0938\u094d\u092a\u0937\u094d\u091f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u0924\u0948\u092f\u093e\u0930 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u091c\u093e\u0902\u091a \u0938\u0947 \u0906\u092a \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0939\u091a\u093e\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u091a\u0932\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u0915\u094b \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0935\u0930\u094d\u0937 \u092e\u0947\u0902 \u090f\u0915 \u092c\u093e\u0930 \u092a\u0942\u0930\u094d\u0923, \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u0932\u093e\u092d \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0927\u0942\u0932 \u092d\u0930\u0947 \u092f\u093e \u0905\u0927\u093f\u0915 \u0909\u092a\u092f\u094b\u0917 \u0935\u093e\u0932\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902, \u0906\u092a\u0915\u094b \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u092c\u0922\u093c\u093e\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0906\u0917\u093e\u092e\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0948\u0932\u0947\u0902\u0921\u0930 \u092f\u093e \u0921\u093f\u091c\u093f\u091f\u0932 \u0930\u093f\u092e\u093e\u0907\u0902\u0921\u0930 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094b \u0928 \u091a\u0942\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930\u0940 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u091f\u0940\u092e \u0938\u0926\u0938\u094d\u092f\u094b\u0902 \u0915\u094b \u0938\u094c\u0902\u092a\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u092e\u092f-\u0938\u093e\u0930\u093f\u0923\u0940 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u094b \u0915\u092e \u092e\u093e\u0902\u0917 \u0935\u093e\u0932\u0947 \u0938\u092e\u092f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u090f\u0915 \u0928\u092e\u0942\u0928\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u0907\u0938 \u092a\u094d\u0930\u0915\u093e\u0930 \u0926\u093f\u0916 \u0938\u0915\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0943\u0924\u094d\u0924\u093f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u094d\u092f\u093e\u092a\u0915 \u091c\u093e\u0901\u091a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0930\u094d\u0937\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u0930\u093f\u0937\u094d\u0920 \u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u092b\u093e\u0908<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u0932<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u091c\u0948\u0938\u0947, IR, BDV)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093e\u0930\u094d\u0937\u093f\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u094b\u0917\u094d\u092f \u0905\u092d\u093f\u092f\u0902\u0924\u093e<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u092d\u093f\u0932\u0947\u0916<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0917\u0924\u093f\u0935\u093f\u0927\u093f \u0915\u093e \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u0905\u091a\u094d\u091b\u0940 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0906\u092a\u0915\u094b \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u094b \u092a\u0939\u091a\u093e\u0928\u0928\u0947, \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0938\u093e\u092c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0914\u0930 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0947 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964  \u0924\u093e\u0930\u0940\u0916, \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930, \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937 \u0914\u0930 \u0915\u0940 \u0917\u0908 \u0915\u093f\u0938\u0940 \u092d\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0930\u0916\u0947\u0902\u0964  \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e, \u0924\u0938\u094d\u0935\u0940\u0930\u0947\u0902 \u0914\u0930 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u0928\u094b\u091f\u094d\u0938 \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902\u0964  \u0907\u0928 \u0930\u093f\u0915\u0949\u0930\u094d\u0921\u094d\u0938 \u0915\u094b \u090f\u0915 \u0915\u0947\u0902\u0926\u094d\u0930\u0940\u092f \u0938\u094d\u0925\u093e\u0928 \u092a\u0930 \u0938\u0902\u0917\u094d\u0930\u0939\u0940\u0924 \u0915\u0930\u0947\u0902, \u091a\u093e\u0939\u0947 \u0935\u0947 \u0915\u093e\u0917\u091c\u093c\u0940 \u092b\u093e\u0907\u0932\u0947\u0902 \u0939\u094b\u0902 \u092f\u093e \u0921\u093f\u091c\u093f\u091f\u0932 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u092e\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0938\u091f\u0940\u0915 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0935\u093e\u0930\u0902\u091f\u0940 \u0926\u093e\u0935\u094b\u0902 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0911\u0921\u093f\u091f \u0915\u094b \u0906\u0938\u093e\u0928 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u090f\u0915 \u0938\u0930\u0932 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u092a\u094d\u0930\u0935\u093f\u0937\u094d\u091f\u093f \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u093f\u0925\u093f<\/p><\/li><li><p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0915 \u0915\u093e \u0928\u093e\u092e<\/p><\/li><li><p>\u0938\u092e\u0940\u0915\u094d\u0937\u093f\u0924 \u0935\u0938\u094d\u0924\u0941\u0913\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a-\u0938\u0942\u091a\u0940<\/p><\/li><li><p>\u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u092e\u0941\u0926\u094d\u0926\u0947 \u0914\u0930 \u0915\u0940 \u0917\u0908 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0907\u092f\u093e\u0901<\/p><\/li><li><p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e (\u091c\u0948\u0938\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0924\u093e\u092a\u092e\u093e\u0928)<\/p><\/li><li><p>\u0905\u0917\u0932\u0940 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0906\u092a \u0907\u0938 \u091c\u093e\u0928\u0915\u093e\u0930\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u0947\u0939\u0924 \u092a\u0930 \u0928\u091c\u093c\u0930 \u0930\u0916\u0928\u0947 \u0914\u0930 \u092e\u0930\u092e\u094d\u092e\u0924 \u092f\u093e \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u092c\u0947\u0939\u0924\u0930 \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u093f\u090f \u0917\u090f \u0928\u093f\u0935\u093e\u0930\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u0947\u0902 \u0906\u092a\u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0938\u0941\u091d\u093e\u0935 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0905\u0927\u093f\u0915 \u0932\u094b\u0921, \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0915\u0928\u0947\u0915\u094d\u091f\u0930\u094d\u0938 \u0914\u0930 \u0922\u0940\u0932\u0947 \u092a\u094d\u0932\u0917\u094d\u0938 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>ISO 9001-2015 \u092f\u093e ISO-12000 \u091c\u0948\u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092f\u0926\u093f \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092e\u0947\u0902 \u0924\u0947\u0932-\u092d\u0930\u0947 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0939\u094b\u0924\u093e \u0939\u0948, \u0924\u094b \u0924\u0947\u0932 \u0915\u093e \u0938\u094d\u0924\u0930 \u091c\u093e\u0902\u091a\u0947\u0902 \u0914\u0930 \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0924\u0925\u093e \u0905\u092e\u094d\u0932\u0940\u092f\u0924\u093e \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092c\u0936\u093f\u0902\u0917\u094d\u0938 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0947\u0902 \u0914\u0930 \u0926\u0930\u093e\u0930\u094b\u0902 \u0924\u0925\u093e \u091c\u092e\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092c\u0922\u093c\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0939\u0930 15 \u0938\u0947 20 \u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0906\u092a\u0915\u0947 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0939\u094b\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u093e \u0909\u092a\u0915\u0930\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0939\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u093e \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0902\u0926\u0930\u094d\u092d \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u092e\u0948\u0928\u0941\u0905\u0932 \u0915\u0940 \u090f\u0915 \u092a\u094d\u0930\u0924\u093f \u0905\u092a\u0928\u0947 \u092a\u093e\u0938 \u0930\u0916\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u0947 \u0915\u094b\u0908 \u092a\u094d\u0930\u0936\u094d\u0928 \u0939\u094b\u0902, \u0924\u094b \u0938\u0932\u093e\u0939 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0924\u0915\u0928\u0940\u0915\u0940 \u0938\u092e\u0930\u094d\u0925\u0928 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u0921\u094d\u0930\u093e\u0908-\u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u0947 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u0928\u093f\u0935\u0947\u0936 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964   \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0939\u091a\u093e\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0938\u0939\u0940 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0924\u094d\u0935\u0930\u093f\u0924 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964   \u091c\u092c \u0906\u092a \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u0938\u0939\u0940 \u091c\u094d\u091e\u093e\u0928 \u0914\u0930 \u0915\u094c\u0936\u0932 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u090f\u0915 \u092e\u091c\u092c\u0942\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0935\u093f\u0937\u092f\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0915\u0947 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u0906\u092a\u0915\u0947 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u0914\u0930 \u092a\u0940\u092a\u0940\u0908 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/p><\/li><li><p>\u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/p><\/li><li><p>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0924\u0915\u0928\u0940\u0915\u0947\u0902<\/p><\/li><li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u092a\u0902\u0916\u094b\u0902 \u0915\u0940 \u0938\u092b\u093e\u0908 \u0915\u0947 \u0924\u0930\u0940\u0915\u0947<\/p><\/li><li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/p><\/li><li><p>\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0947 \u091a\u0930\u0923<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0906\u092a \u0915\u0915\u094d\u0937\u093e-\u0906\u0927\u093e\u0930\u093f\u0924 \u0936\u093f\u0915\u094d\u0937\u0923, \u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u0905\u092d\u094d\u092f\u093e\u0938 \u0914\u0930 \u0911\u0928\u0932\u093e\u0907\u0928 \u092e\u0949\u0921\u094d\u092f\u0942\u0932 \u0915\u093e \u092e\u093f\u0936\u094d\u0930\u0923 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0906\u092a\u0915\u0940 \u091f\u0940\u092e \u0915\u094b \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u0938\u093f\u0916\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0938\u0924\u094d\u0930\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u094d\u0930\u0936\u094d\u0928 \u092a\u0942\u091b\u0928\u0947 \u0914\u0930 \u091a\u0930\u094d\u091a\u093e \u0915\u094b \u092a\u094d\u0930\u094b\u0924\u094d\u0938\u093e\u0939\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0938\u092d\u0940 \u0915\u094b \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u094b \u0938\u092e\u091d\u0928\u0947 \u0914\u0930 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0907\u0938\u0947 \u0932\u093e\u0917\u0942 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u0930 \u0938\u093e\u0932 \u0915\u094c\u0936\u0932 \u0915\u094b \u0924\u0940\u0915\u094d\u0937\u094d\u0923 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0914\u0930 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u0928\u090f \u092e\u093e\u0928\u0915\u094b\u0902 \u092f\u093e \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0938\u0947 \u0905\u0935\u0917\u0924 \u0915\u0930\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u092b\u094d\u0930\u0947\u0936\u0930 \u0915\u094b\u0930\u094d\u0938 \u0906\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0928\u090f \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u092d\u0935\u0940 \u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928\u094b\u0902 \u0915\u094b \u092e\u0947\u0902\u091f\u0930 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0928\u093f\u092f\u0941\u0915\u094d\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092e\u0947\u0902\u091f\u0930 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u090f\u0901 \u0938\u093e\u091d\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0915\u092e \u0905\u0928\u0941\u092d\u0935\u0940 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u091c\u091f\u093f\u0932 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u092e\u0947\u0902 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u0928 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u091c\u092c \u0906\u092a \u0928\u090f \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0905\u0928\u0941\u092d\u0935\u0940 \u092a\u0947\u0936\u0947\u0935\u0930\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0906\u0924\u094d\u092e\u0935\u093f\u0936\u094d\u0935\u093e\u0938 \u0914\u0930 \u091f\u0940\u092e \u0935\u0930\u094d\u0915 \u0915\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092a\u094d\u0930\u0917\u0924\u093f \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u093f \u0938\u092d\u0940 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u0906\u092a\u0915\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u0947 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939\u093e\u0901 \u090f\u0915 \u0909\u0926\u093e\u0939\u0930\u0923 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0935\u093f\u0937\u092f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u0942\u0930\u094d\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0926\u093f\u0928\u093e\u0902\u0915<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0915<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2610<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u0949\u0915\u0906\u0909\u091f\/\u091f\u0948\u0917\u0906\u0909\u091f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2610<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0924\u0915\u0928\u0940\u0915\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2610<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u092b\u093e\u0908 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2610<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2610<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2610<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u092d\u0940 \u092a\u0942\u0930\u094d\u0923 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0938\u0924\u094d\u0930\u094b\u0902 \u0915\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0911\u0921\u093f\u091f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0938\u093e\u092c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0938\u0941\u0927\u093e\u0930 \u0915\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0906\u092a\u0915\u0940 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0914\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u094b\u0902 \u0938\u0947 \u0905\u092a\u0921\u0947\u091f\u0947\u0921 \u0930\u0939\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u0915\u093e\u0930\u094d\u092f\u0936\u093e\u0932\u093e\u0913\u0902, \u0935\u0947\u092c\u093f\u0928\u093e\u0930\u094b\u0902 \u092f\u093e \u092a\u094d\u0930\u092e\u093e\u0923\u0928 \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e\u094b\u0902 \u092e\u0947\u0902 \u092d\u093e\u0917 \u0932\u0947\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u094b\u0924\u094d\u0938\u093e\u0939\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u0906\u092a \u0928\u090f \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u092f\u093e \u0909\u0928\u094d\u0928\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093f\u0927\u093f\u092f\u094b\u0902 \u092a\u0930 \u0935\u093f\u0936\u0947\u0937 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0938\u0924\u094d\u0930 \u0906\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e\u094b\u0902 \u0915\u094b \u092d\u0940 \u0906\u092e\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u091a\u0947\u0924\u093e\u0935\u0928\u0940:<\/strong> \u0905\u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0915\u092d\u0940 \u0928 \u0926\u0947\u0902\u0964 \u091c\u092c \u0906\u092a \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0938\u092d\u0940 \u0915\u094b \u0909\u091a\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948, \u0924\u094b \u0906\u092a \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0914\u0930 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u0940 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0915\u0941\u0936\u0932 \u0915\u093e\u0930\u094d\u092f\u0938\u094d\u0925\u0932 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u0940 \u091f\u0940\u092e \u0906\u0924\u094d\u092e\u0935\u093f\u0936\u094d\u0935\u093e\u0938 \u0915\u0947 \u0938\u093e\u0925 \u0915\u093e\u092e \u0915\u0930\u0947\u0917\u0940, \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0917\u0940, \u0914\u0930 \u0906\u092a\u0915\u0947 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b \u092c\u0922\u093c\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0947\u0917\u0940\u0964.<\/p>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u094b \u092e\u091c\u092c\u0942\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0927\u0942\u0932 \u0915\u0947 \u091c\u092e\u093e\u0935 \u0914\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0938\u092b\u093e\u0908 \u0915\u093e \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c\u094d\u0921 \u0915\u0930\u0928\u0947 \u092a\u0930 \u0939\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0915\u0938\u0947\u0902 \u0914\u0930 \u0922\u0940\u0932\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092c\u0926\u0932\u0947\u0902\u0964.<\/p><\/li><li><p>\u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0947 \u0932\u093f\u090f \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092a\u0930 \u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0939\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u092f\u093e \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u0909\u092a\u0947\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u093e <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0930\u094b\u0915\u0925\u093e\u092e \u0938\u0902\u092c\u0902\u0927\u0940 \u0930\u0916\u0930\u0916\u093e\u0935<\/a> \u0907\u0938\u0938\u0947 \u0916\u0930\u093e\u092c \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0914\u0930 \u0916\u0924\u0930\u0928\u093e\u0915 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964 \u091c\u091f\u093f\u0932 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u090f\u0915 \u0928\u093f\u0935\u093e\u0930\u0915 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e\u094b\u0902 \u0938\u0947 \u092a\u0930\u093e\u092e\u0930\u094d\u0936 \u0915\u0930\u0947\u0902\u0964 \u0905\u092a\u0928\u0940 \u0938\u0902\u092a\u0924\u094d\u0924\u093f \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u091c \u0939\u0940 \u0905\u092a\u0928\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e \u0936\u0941\u0930\u0942 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0936\u0941\u0937\u094d\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094d\u092f\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0924\u093f\u092e\u093e\u0939\u0940 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0914\u0930 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0935\u094d\u092f\u093e\u092a\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0927\u0942\u0932 \u092d\u0930\u0947 \u092f\u093e \u0915\u0920\u094b\u0930 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094b \u0939\u0930 \u0924\u0940\u0928 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902 \u092c\u0922\u093c\u093e \u0926\u0947\u0902\u0964 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0905\u0902\u0924\u0930\u093e\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0915\u094d\u092f\u093e \u0906\u092a \u090f\u0915 \u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092f\u0941\u0915\u094d\u0924 \u0930\u0939\u0924\u0947 \u0939\u0941\u090f \u0938\u093e\u092b \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u090a\u0930\u094d\u091c\u093e \u092f\u0941\u0915\u094d\u0924 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0906\u092a\u0915\u094b \u0915\u092d\u0940 \u092d\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u0938\u092b\u093e\u0908 \u0928\u0939\u0940\u0902 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0947\u0935\u0932 \u0909\u091a\u093f\u0924 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 (PPE) \u0915\u0947 \u0938\u093e\u0925 \u0917\u0948\u0930-\u0906\u0915\u094d\u0930\u093e\u092e\u0915 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0924\u093e\u092a\u092e\u093e\u0928 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0938\u092b\u093e\u0908 \u092f\u093e \u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0907\u0915\u093e\u0908 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0930\u0939\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u0938\u092c\u0938\u0947 \u0906\u092e \u0932\u0915\u094d\u0937\u0923 \u0915\u094d\u092f\u093e \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940, \u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e, \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0906\u0935\u093e\u091c\u093c\u0947\u0902, \u091c\u0932\u0928\u0947 \u0915\u0940 \u0917\u0902\u0927 \u0914\u0930 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u0928\u092e\u0940, \u0927\u0942\u0932 \u0915\u093e \u091c\u092e\u093e\u0935 \u0914\u0930 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092d\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u092e\u0939\u0902\u0917\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094d\u092f\u094b\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948?<\/h3>\n\n\n\n<p>\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0907\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u093f \u092f\u0939 \u0917\u0902\u092d\u0940\u0930 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0947\u0964 PD \u0917\u0924\u093f\u0935\u093f\u0927\u093f \u0915\u0940 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u0906\u092a\u0915\u094b \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0920\u0939\u0930\u093e\u0935 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0927\u0942\u0932 \u091c\u092e\u093e \u0939\u094b\u0928\u0947 \u0938\u0947 \u0906\u092a \u0915\u0948\u0938\u0947 \u0930\u094b\u0915\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u094b\u0930\u094d\u091f\u094d\u0938 \u092a\u0930 \u092b\u093c\u093f\u0932\u094d\u091f\u0930 \u0932\u0917\u093e\u090f\u0901 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0938\u094d\u0935\u091a\u094d\u091b \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964 \u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u092b\u093e\u0908 \u0914\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964 \u0909\u091a\u093f\u0924 \u0935\u093e\u092f\u0941 \u092a\u094d\u0930\u0935\u093e\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0935\u0930\u094b\u0927 \u0914\u0930 \u092e\u0932\u092c\u093e \u0924\u0941\u0930\u0902\u0924 \u0939\u091f\u093e\u090f\u0901\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0928\u092e\u0940 \u092e\u093f\u0932 \u091c\u093e\u090f \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0938\u0941\u0916\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0914\u0930 \u0930\u093f\u0938\u093e\u0935 \u0915\u0947 \u0938\u094d\u0930\u094b\u0924 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0915\u093e\u0908 \u0915\u094b \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0935\u093e\u092a\u0938 \u0932\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u0940\u0932 \u092f\u093e \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902\u0964 \u0928\u092e\u0940 \u0936\u0940\u0918\u094d\u0930 \u0939\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0916\u0930\u093e\u092c \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0921\u094d\u0930\u093e\u0908 \u091f\u093e\u0907\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093f\u0938\u0947 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947\u0935\u0932 \u092f\u094b\u0917\u094d\u092f \u0914\u0930 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0939\u0940 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0928\u0941\u092d\u0935\u0940 \u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0906\u092a \u091c\u094b\u0916\u093f\u092e\u094b\u0902 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u092c\u093e\u0926 \u0906\u092a\u0915\u094b \u0915\u094c\u0928 \u0938\u0947 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0930\u0916\u0928\u0947 \u091a\u093e\u0939\u093f\u090f?<\/h3>\n\n\n\n<p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0924\u093f\u0925\u093f\u092f\u093e\u0901, \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937, \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e, \u092e\u0930\u092e\u094d\u092e\u0924 \u0914\u0930 \u0924\u0938\u094d\u0935\u0940\u0930\u094b\u0902 \u0938\u0939\u093f\u0924 \u090f\u0915 \u0932\u0949\u0917 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964 \u0905\u091a\u094d\u091b\u0947 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092a\u0930 \u0928\u091c\u093c\u0930 \u0930\u0916\u0928\u0947, \u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u0914\u0930 \u0935\u093e\u0930\u0902\u091f\u0940 \u0926\u093e\u0935\u094b\u0902 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0938\u092b\u093e\u0908 \u0915\u0947 \u0938\u093e\u0925 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092c\u0922\u093c\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>","protected":false},"author":3,"featured_media":1581,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-1583","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=1583"}],"version-history":[{"count":3,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1583\/revisions"}],"predecessor-version":[{"id":3518,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1583\/revisions\/3518"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/1581"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=1583"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=1583"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=1583"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}