{"id":1589,"date":"2025-11-29T21:21:37","date_gmt":"2025-11-29T21:21:37","guid":{"rendered":"https:\/\/xbrele.com\/distribution-transformer-testing-checklist-for-engineers\/"},"modified":"2026-04-07T15:09:21","modified_gmt":"2026-04-07T15:09:21","slug":"distribution-transformer-testing-checklist-for-engineers","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/distribution-transformer-testing-checklist-for-engineers\/","title":{"rendered":"\u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a.jpg\" alt=\"\u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f\" class=\"wp-image-1585\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a.jpg 1408w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-300x164.jpg 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-1024x559.jpg 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-768x419.jpg 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/fff545768c964237b726a4983028707a-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u092b\u0940\u0932\u094d\u0921 \u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u0908 \u091a\u0941\u0928\u094c\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u0924\u093e \u0939\u0948\u0964 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0928\u0947 \u092f\u093e \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0932\u0917\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092f\u093e \u092c\u093e\u0926 \u092e\u0947\u0902 \u0909\u0938\u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f, \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u093e\u0964 \u0906\u092a \u090f\u0915 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0905\u092a\u0928\u093e\u0915\u0930 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0914\u0930 \u0932\u094b\u0917\u094b\u0902 \u0924\u0925\u093e \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0915\u0908 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930 \u0924\u0930\u0932-\u0921\u0942\u092c\u0947 \u0939\u0941\u090f \u0907\u0915\u093e\u0907\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f IEEE C57.12.00 \u0914\u0930 \u0938\u0942\u0916\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u092e\u0949\u0921\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f IEEE C57.12.01 \u091c\u0948\u0938\u0947 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u092e\u0947\u0902 \u0935\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092e\u093e\u0928\u0915 \u0938\u0942\u091a\u0940\u092c\u0926\u094d\u0927 \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0906\u092a \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0928\u0915<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0947\u0926\u0928<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0908\u0908\u0908 \u0938\u094057.12.00<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0930\u0932-\u0921\u0942\u092c\u0947 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0908\u0908\u0908 \u0938\u094057.12.90<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0915\u094d\u0924\u093f \u0914\u0930 \u0935\u093f\u0928\u093f\u092f\u093e\u092e\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0908\u0908\u0908 \u0938\u094057.12.01<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0941\u0937\u094d\u0915-\u092a\u094d\u0930\u0915\u093e\u0930 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0908\u0908\u0908 \u0938\u094057.12.91<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0936\u0941\u0937\u094d\u0915-\u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u0932\u093f\u090f \u092a\u093e\u0935\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u092e\u0941\u0916\u094d\u092f \u092c\u093e\u0924\u0947\u0902<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0938\u092e\u091d\u0947\u0902 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u092e\u0939\u0924\u094d\u0935<\/a> \u0938\u0941\u0930\u0915\u094d\u0937\u093e, \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f\u0964.<\/p><\/li><li><p>\u092c\u093f\u091c\u0932\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u091c\u0948\u0938\u0947 \u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0924\u0947\u0932 \u0930\u093f\u0938\u093e\u0935 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u091b\u093f\u092a\u0947 \u0939\u0941\u090f \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0938\u0939\u093f\u0924 \u0906\u0935\u0936\u094d\u092f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0947\u0932 \u0915\u093e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0930\u0947\u0902<\/a> \u0917\u0948\u0938\u094b\u0902, \u0928\u092e\u0940 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0905\u092a\u091a\u092f \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0928\u093e, \u091c\u094b \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u093f \u0915\u094b\u0908 \u092d\u0940 \u091a\u0930\u0923 \u091b\u0942\u091f\u0947 \u0928, \u090f\u0915 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902, \u091c\u094b \u0926\u0943\u0936\u094d\u092f \u091c\u093e\u0902\u091a \u0938\u0947 \u0936\u0941\u0930\u0942 \u0939\u094b\u0915\u0930 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092a\u0930 \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0902\u092c\u0902\u0927\u0940 \u0928\u093f\u0930\u094d\u0923\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u0939\u093e\u092f\u0924\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u092d\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0938\u091f\u0940\u0915 \u0930\u0942\u092a \u0938\u0947 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0909\u091a\u093f\u0924 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 \u092a\u0939\u0928\u0915\u0930 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u094d\u0925\u0932 \u092e\u0947\u0902 \u0916\u0924\u0930\u094b\u0902 \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0915\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0947\u0902\u0964.<\/p><\/li><li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u092c\u0922\u093c\u093e\u0928\u0947 \u0914\u0930 \u0917\u094d\u0930\u093f\u0921 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u0913\u0902 \u0914\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0938\u0947 \u0905\u092a\u0921\u0947\u091f \u0930\u0939\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0935\u0932\u094b\u0915\u0928<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0948\u0938\u0947 \u0915\u0930\u0947\u0902\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/cmvZoWYE-No?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f \u0914\u0930 \u0926\u093e\u092f\u0930\u093e<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092f\u0939 \u0938\u092e\u091d\u0928\u093e \u0939\u094b\u0917\u093e \u0915\u093f \u0935\u093f\u0924\u0930\u0923 \u0915\u094d\u092f\u094b\u0902\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/a> \u0915\u093f\u0938\u0940 \u092d\u0940 \u0915\u093e\u0930\u094d\u092f \u0915\u094b \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092f\u0947 \u0915\u093e\u0930\u094d\u092f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0906\u092a\u0915\u0947 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a \u0907\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0916\u093e\u092e\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u092e\u091c\u092c\u0942\u0924\u0940 \u092e\u093e\u092a\u0928\u0947 \u0914\u0930 \u092f\u0939 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u092e\u0947\u0936\u093e \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0916\u0924\u0930\u0928\u093e\u0915 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0947\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0905\u0902\u0924\u0930\u094d\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u092e\u093e\u0928\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0915\u0908 \u092e\u0941\u0916\u094d\u092f \u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f\u094b\u0902 \u0915\u094b \u0930\u0947\u0916\u093e\u0902\u0915\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u093f\u0916\u093e\u0924\u0940 \u0939\u0948 \u0915\u093f \u0906\u092a \u0915\u094d\u092f\u093e \u0939\u093e\u0938\u093f\u0932 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u0905\u0928\u0926\u0947\u0916\u0947 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0906\u0917 \u0915\u0947 \u0916\u0924\u0930\u094b\u0902, \u0924\u0947\u0932 \u0915\u0947 \u0935\u093f\u0938\u094d\u092b\u094b\u091f\u094b\u0902 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u092e\u093f\u0932\u0924\u0940 \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0914\u0930 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u0905\u0928\u0941\u092a\u093e\u0932\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>IEC \u0914\u0930 IEEE \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0911\u0921\u093f\u091f \u0915\u0947 \u0932\u093f\u090f \u0905\u0915\u094d\u0938\u0930 \u0915\u093e\u0928\u0942\u0928\u0940 \u0930\u0942\u092a \u0938\u0947 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0924 \u092e\u0947\u0902 \u0915\u092e\u0940<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0924\u093e \u0939\u0948, \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u093e\u0917\u0924 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0917\u094d\u0930\u093f\u0921 \u0938\u094d\u0925\u093f\u0930\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0928\u093f\u092f\u092e\u0928 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0917\u094d\u0930\u093f\u0921 \u0905\u0938\u094d\u0925\u093f\u0930\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0906\u092a \u0915\u0908 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0917\u0947\u0964 \u0907\u0928\u092e\u0947\u0902 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923, \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923, <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/a>, \u0914\u0930 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u091c\u093e\u0901\u091a\u0947\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0921\u0947\u091f\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092e\u0941\u0916\u094d\u092f \u0932\u093e\u092d<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0905\u092a\u0928\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u0908 \u0932\u093e\u092d \u092e\u093f\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0939\u091a\u093e\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0938\u0947 \u0906\u092a\u0915\u093e \u0916\u0930\u094d\u091a \u092c\u091a\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u093e \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u091a\u0932\u0924\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0906\u092a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0914\u0930 \u0924\u0947\u0932 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u092a\u0930 \u0921\u0947\u091f\u093e \u090f\u0915\u0924\u094d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0906\u092a\u0915\u094b \u0938\u094d\u092e\u093e\u0930\u094d\u091f \u0930\u0916\u0930\u0916\u093e\u0935 \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u0947\u0939\u0924 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u092c\u0942\u0922\u093c\u0947 \u0939\u094b\u0928\u0947 \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0938\u094d\u0925\u093f\u0924\u093f \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0914\u0930 \u091f\u093f\u0915\u093e\u090a \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>\u0906\u092a \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0915\u0930 \u0905\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>\u0907\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0947 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0921\u0947\u091f\u093e-\u0906\u0927\u093e\u0930\u093f\u0924 \u0928\u093f\u0930\u094d\u0923\u092f \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0917\u094d\u0930\u093f\u0921 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0915\u0902\u092a\u0928\u093f\u092f\u093e\u0901 \u0928\u093f\u092f\u092e\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u0938\u094d\u092a\u0937\u094d\u091f \u0932\u093e\u092d \u0926\u0947\u0916\u0924\u0940 \u0939\u0948\u0902\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u0907\u0928 \u0932\u093e\u092d\u094b\u0902 \u092e\u0947\u0902 \u0938\u0947 \u0915\u0941\u091b \u0915\u094b \u0909\u091c\u093e\u0917\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u092d<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u0936\u0940\u0918\u094d\u0930 \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0938\u0915\u094d\u0930\u093f\u092f \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0902\u092d\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0932\u093e\u0917\u0924 \u092c\u091a\u0924<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0914\u0930 \u0905\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0914\u0930 \u0909\u0938\u0938\u0947 \u091c\u0941\u0921\u093c\u0940 \u0932\u093e\u0917\u0924\u0947\u0902 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092c\u0947\u0939\u0924\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u093f\u0938\u0902\u092a\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0915\u0947 \u092a\u093e\u0935\u0930 \u0917\u094d\u0930\u093f\u0921 \u0915\u0940 \u0938\u092e\u0917\u094d\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0938\u094d\u0925\u093f\u0930\u0924\u093e \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0906\u092a \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0917\u094d\u0930\u093f\u0921 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u0942\u092e\u093f\u0915\u093e \u0928\u093f\u092d\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u090f\u0915 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0915\u0947, \u0906\u092a \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u092e\u0939\u0902\u0917\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0938\u0947 \u092c\u091a\u093e\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u092c\u093f\u091c\u0932\u0940 \u0915\u0940 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0928\u093f\u0930\u0902\u0924\u0930 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0924\u0948\u092f\u093e\u0930\u0940<\/h2>\n\n\n\n<p>\u0915\u093f\u0938\u0940 \u092d\u0940 \u091a\u0940\u091c\u093c \u0915\u094b \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/a>, \u0906\u092a\u0915\u094b \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0924\u0948\u092f\u093e\u0930\u0940 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u091a\u094d\u091b\u0940 \u0924\u0948\u092f\u093e\u0930\u0940 \u0906\u092a\u0915\u094b \u0917\u0932\u0924\u093f\u092f\u093e\u0901 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u094b\u0902 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0928\u093f\u092f\u092e\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0914\u0930 \u0938\u0939\u0940 \u0909\u092a\u0915\u0930\u0923 \u0907\u0915\u091f\u094d\u0920\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0938\u092e\u0940\u0915\u094d\u0937\u093e<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u092d\u0940 \u092a\u094d\u0930\u093e\u0938\u0902\u0917\u093f\u0915 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u0915\u0926\u092e \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0907\u0924\u093f\u0939\u093e\u0938 \u0914\u0930 \u0924\u0915\u0928\u0940\u0915\u0940 \u0935\u093f\u0935\u0930\u0923\u094b\u0902 \u0915\u094b \u0938\u092e\u091d\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u094b\u0902 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0947 \u0938\u0947 \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0935\u093f\u0936\u0947\u0937 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u092e\u0947\u0902 \u092d\u0940 \u092e\u0926\u0926 \u092e\u093f\u0932\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0928\u093e\u092e\u092a\u091f\u094d\u091f\u0940 \u0921\u0947\u091f\u093e<\/h4>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0928\u0947\u092e\u092a\u094d\u0932\u0947\u091f \u092a\u0922\u093c\u0915\u0930 \u0936\u0941\u0930\u0941\u0906\u0924 \u0915\u0930\u0947\u0902\u0964 \u0928\u0947\u092e\u092a\u094d\u0932\u0947\u091f \u0906\u092a\u0915\u094b \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0947\u091f\u093f\u0902\u0917, \u0915\u0930\u0902\u091f \u0930\u0947\u091f\u093f\u0902\u0917, \u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u0914\u0930 \u0938\u0940\u0930\u093f\u092f\u0932 \u0928\u0902\u092c\u0930 \u091c\u0948\u0938\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u091c\u093e\u0928\u0915\u093e\u0930\u0940 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a \u0907\u0938 \u0921\u0947\u091f\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0947 \u0914\u0930 \u092f\u0939 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0905\u092a\u0928\u0940 \u0935\u093f\u0936\u093f\u0937\u094d\u091f\u0924\u093e\u0913\u0902 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0924\u093e \u0939\u0948\u0964 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0932\u0949\u0917 \u092e\u0947\u0902 \u0928\u0947\u092e\u092a\u094d\u0932\u0947\u091f \u0915\u093e \u0935\u093f\u0935\u0930\u0923 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/h4>\n\n\n\n<p>\u0905\u0917\u0932\u093e, \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902\u0964 \u092f\u0947 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0906\u092a\u0915\u094b \u0921\u093f\u091c\u093c\u093e\u0907\u0928, \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0914\u0930 \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u092c\u0924\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0935\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u093e\u0928\u094b\u0902 \u0915\u0940 \u0938\u0940\u092e\u093e\u090f\u0901 \u092d\u0940 \u0938\u0942\u091a\u0940\u092c\u0926\u094d\u0927 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a \u0928\u093e\u092e\u092a\u091f\u094d\u091f\u093f\u0915\u093e \u0914\u0930 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0915\u094b\u0908 \u0905\u0902\u0924\u0930 \u092a\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u0917\u0947 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u0909\u0928\u094d\u0939\u0947\u0902 \u0928\u094b\u091f \u0915\u0930 \u0932\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u093f\u091b\u0932\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0914\u0930 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0940 \u092d\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u092e\u0947\u0902 \u0909\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u094b\u0902 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u0938\u0942\u091a\u0940 \u0926\u0940 \u0917\u0908 \u0939\u0948 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0906\u092a\u0915\u094b \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0906\u0935\u0936\u094d\u092f\u0915 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u092e\u0947\u0917\u0930) \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u092a\u093e\u0924, \u0927\u094d\u0930\u0941\u0935\u0940\u092f\u0924\u093e, \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0935\u093f\u0935\u0930\u0923, \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0921\u0947\u091f\u093e \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u093e\u092f<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094b \u092a\u0939\u0932\u0947 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a \u0909\u091a\u093f\u0924 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0916\u0924\u0930\u0928\u093e\u0915 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u093e\u0907\u091f \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f \u0928\u093f\u0915\u093e\u0932\u0947\u0902 \u0914\u0930 \u0938\u0939\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e\u0924\u094d\u092e\u0915 \u0909\u092a\u0915\u0930\u0923 \u092a\u0939\u0928\u0947\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923<\/h4>\n\n\n\n<p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0926\u0938\u094d\u0924\u093e\u0928\u0947, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091a\u0936\u094d\u092e\u093e \u0914\u0930 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u092a\u0921\u093c\u094b\u0902 \u091c\u0948\u0938\u0947 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 (PPE) \u092a\u0939\u0928\u0947\u0902\u0964 PPE \u0906\u092a\u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091d\u091f\u0915\u094b\u0902, \u091c\u0932\u0928\u0947 \u0914\u0930 \u0905\u0928\u094d\u092f \u0916\u0924\u0930\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0906\u092a\u0915\u093e \u0909\u092a\u0915\u0930\u0923 \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u092b\u093f\u091f \u0939\u094b \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0939\u094b\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0938\u093e\u0907\u091f \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928<\/h4>\n\n\n\n<p>\u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u093e\u0907\u091f \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0918\u0942\u092e\u0947\u0902\u0964 \u0917\u0940\u0932\u0940 \u0938\u0924\u0939\u0947\u0902, \u0916\u0930\u093e\u092c \u0930\u094b\u0936\u0928\u0940 \u092f\u093e \u0905\u0935\u0930\u094b\u0927 \u091c\u0948\u0938\u0940 \u0916\u0924\u0930\u094b\u0902 \u0915\u0940 \u0924\u0932\u093e\u0936 \u0915\u0930\u0947\u0902\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0905\u0928\u0927\u093f\u0915\u0943\u0924 \u0932\u094b\u0917\u094b\u0902 \u0938\u0947 \u092e\u0941\u0915\u094d\u0924 \u0939\u0948\u0964 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u092d\u0940 \u0932\u0949\u0915\u0906\u0909\u091f \u0914\u0930 \u091f\u0948\u0917\u0906\u0909\u091f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901 \u0932\u093e\u0917\u0942 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0915\u0926\u092e \u0906\u092a\u0915\u094b \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0940 \u091f\u0940\u092e \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0909\u092a\u0915\u0930\u0923 \u0914\u0930 \u0914\u091c\u093e\u0930<\/h3>\n\n\n\n<p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u092d\u0940 \u0909\u092a\u0915\u0930\u0923 \u0914\u0930 \u0914\u091c\u093e\u0930 \u0907\u0915\u091f\u094d\u0920\u093e \u0915\u0930 \u0932\u0947\u0902\u0964 \u0906\u092a\u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0947\u0902\u0938 \u091f\u0947\u0938\u094d\u091f\u0930\u094d\u0938, \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0947\u0902\u0938 \u092e\u0940\u091f\u0930\u094d\u0938 \u0914\u0930 \u091f\u0930\u094d\u0928\u094d\u0938 \u0930\u0947\u0936\u093f\u092f\u094b \u091f\u0947\u0938\u094d\u091f\u0930\u094d\u0938 \u091c\u0948\u0938\u0947 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f\u0947\u0921 \u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0917\u0940\u0964 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0939\u0948\u0902\u0921 \u091f\u0942\u0932\u094d\u0938, \u0938\u092b\u093e\u0908 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0914\u0930 \u090f\u0915 \u0915\u0948\u092e\u0930\u093e \u0938\u093e\u0925 \u0932\u093e\u090f\u0901\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u092d\u0940 \u0909\u092a\u0915\u0930\u0923 \u0920\u0940\u0915 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930 \u0930\u0939\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0909\u0928\u0915\u0947 \u092a\u093e\u0938 \u0935\u0948\u0927 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0938\u093e\u0907\u091f \u092a\u0930 \u091c\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0942\u091a\u0940 \u0926\u094b\u092c\u093e\u0930\u093e \u091c\u093e\u0902\u091a\u0947\u0902\u0964 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0915\u092e\u0940 \u0906\u092a\u0915\u0947 \u0915\u093e\u092e \u092e\u0947\u0902 \u0926\u0947\u0930\u0940 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u091c\u094b\u0916\u093f\u092e \u092c\u0922\u093c\u093e \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3.webp\" alt=\"\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\" class=\"wp-image-1586\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/9de1bbe3611d48fb90b7146cf12e0dc3-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u091b\u0935\u093f \u0938\u094d\u0930\u094b\u0924: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">\u092a\u0947\u0915\u094d\u0938\u0932\u094d\u0938<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u0947\u0939\u0924 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u092a\u0939\u0932\u0940 \u091c\u093e\u0928\u0915\u093e\u0930\u0940 \u0926\u0947\u0924\u093e \u0939\u0948\u0964  \u0907\u0915\u093e\u0908 \u0914\u0930 \u0909\u0938\u0915\u0947 \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u0927\u094d\u092f\u093e\u0928 \u0938\u0947 \u0926\u0947\u0916\u0915\u0930 \u0906\u092a \u0915\u0908 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0917\u0902\u092d\u0940\u0930 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u0940 \u092a\u0939\u091a\u093e\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964  \u0915\u093f\u0938\u0940 \u092d\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094b \u091a\u0932\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u092e\u0947\u0936\u093e \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092c\u093e\u0939\u0930\u0940 \u091c\u093e\u0901\u091a\u0947\u0902<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f<\/h4>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0918\u0942\u092e\u0915\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u091f\u0948\u0902\u0915, \u0906\u0935\u0930\u0923 \u0914\u0930 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902\u0964 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u0915\u0947\u0924 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u091f\u0948\u0902\u0915 \u092f\u093e \u0906\u0935\u0930\u0923 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u0927\u0915\u094d\u0915\u0947<\/p><\/li><li><p>\u0927\u093e\u0924\u0941 \u0915\u0940 \u0938\u0924\u0939\u094b\u0902 \u092a\u0930 \u091c\u0902\u0917 \u092f\u093e \u0915\u094d\u0937\u0930\u0923<\/p><\/li><li><p>\u0922\u0940\u0932\u0947 \u092f\u093e \u0917\u093e\u092f\u092c \u092c\u094b\u0932\u094d\u091f \u0914\u0930 \u092b\u093e\u0938\u094d\u091f\u0928\u0930<\/p><\/li><li><p>\u0915\u0928\u0947\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u092a\u093e\u0938 \u091c\u0932\u0928\u0947 \u0915\u0947 \u0928\u093f\u0936\u093e\u0928 \u092f\u093e \u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u093e<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0915\u0920\u093f\u0928 \u0938\u0947 \u0926\u093f\u0916\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u091f\u0949\u0930\u094d\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u0940 \u0924\u0938\u094d\u0935\u0940\u0930\u0947\u0902 \u0905\u092a\u0928\u0947 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0947 \u0932\u093f\u090f \u0932\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0924\u0947\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935<\/h4>\n\n\n\n<p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0924\u0947\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935<\/a> \u0917\u0902\u092d\u0940\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0938\u092d\u0940 \u0938\u0940\u092e\u094b\u0902, \u0917\u0948\u0938\u094d\u0915\u0947\u091f\u094d\u0938 \u0914\u0930 \u092b\u093f\u091f\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0930\u093f\u0938\u093e\u0935 \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u091f\u0948\u0902\u0915 \u092f\u093e \u091c\u092e\u0940\u0928 \u092a\u0930 \u0924\u0947\u0932 \u0915\u0947 \u0926\u093e\u0917<\/p><\/li><li><p>\u0917\u0948\u0938\u094d\u0915\u0947\u091f \u092f\u093e \u092c\u0941\u0936\u093f\u0902\u0917 \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0917\u0940\u0932\u0947 \u0927\u092c\u094d\u092c\u0947<\/p><\/li><li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0928\u0940\u091a\u0947 \u091f\u092a\u0915\u0928\u093e \u092f\u093e \u0917\u0921\u094d\u0922\u0947<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0930\u093f\u0938\u093e\u0935 \u092e\u093f\u0932\u0947\u0902, \u0924\u094b \u0909\u0928\u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0914\u0930 \u092e\u093e\u0924\u094d\u0930\u093e \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u0930\u093f\u0938\u093e\u0935 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0914\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u092c\u093e\u0939\u0930\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0924\u0947\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935, \u0926\u0930\u093e\u0930\u0947\u0902 \u0914\u0930 \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u0938\u092c\u0938\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0926\u0943\u0936\u094d\u092f \u0938\u0902\u0915\u0947\u0924 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u0902\u0924\u0930\u093f\u0915 \u091c\u093e\u0901\u091a\u0947\u0902<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0915\u094b\u0930 \u0914\u0930 \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938<\/h4>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u0947 \u092a\u093e\u0938 \u092a\u0939\u0941\u0901\u091a \u0939\u094b \u0924\u094b \u0915\u094b\u0930 \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0935\u0936\u094d\u092f \u0915\u0930\u0947\u0902\u0964   \u090f\u0915 \u0935\u094d\u092f\u093e\u092a\u0915 \u091c\u093e\u0901\u091a \u0915\u0947 \u0932\u093f\u090f \u0907\u0928 \u091a\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u092d\u094c\u0924\u093f\u0915 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0915\u0930\u0947\u0902\u0964 \u0932\u0948\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u0940 \u092e\u094b\u091f\u093e\u0908, \u0935\u093f\u0902\u0921\u094b \u0915\u0940 \u090a\u0901\u091a\u093e\u0908 \u0914\u0930 \u0915\u0941\u0932 \u090a\u0901\u091a\u093e\u0908 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u0905\u092a\u0928\u0940 \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u092e\u093e\u0928\u094b\u0902 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0915\u094b\u0930 \u0906\u0907\u0938\u094b\u0932\u0947\u0936\u0928 \u091f\u0947\u0938\u094d\u091f \u091a\u0932\u093e\u090f\u0901\u0964 \u0915\u094b\u0930 \u0914\u0930 \u0927\u093e\u0924\u0941 \u0915\u094d\u0932\u0948\u0902\u092a \u0915\u0947 \u092c\u0940\u091a \u0936\u0949\u0930\u094d\u091f\u094d\u0938 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0947\u0902\u0938 (IR) \u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f IR \u092e\u093e\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u0947 \u0939\u094b\u0902\u0964.<\/p><\/li><li><p>\u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0938\u094d\u091f\u094d\u0930\u093f\u092a\u094d\u0938 \u0915\u0940 \u092e\u094b\u091f\u093e\u0908 \u0914\u0930 \u091a\u094c\u0921\u093c\u093e\u0908 \u092e\u093e\u092a\u0947\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092e\u0947\u0902 \u0921\u093f\u0938\u094d\u0915 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0947\u0902\u0964 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0915\u0930\u0915\u0947 \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u092e\u093e\u092a\u0915\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u0935\u093f\u0927\u093f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u092f\u0947 \u091a\u0930\u0923 \u0906\u092a\u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u091f\u0930\u094d\u0928, \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0937 \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928<\/h4>\n\n\n\n<p>\u0938\u092d\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u092a\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0930\u0902\u0917 \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e \u092f\u093e \u091d\u0941\u0932\u0938 \u091c\u093e\u0928\u093e<\/p><\/li><li><p>\u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u091b\u0940\u0932\u0928<\/p><\/li><li><p>\u0928\u092e\u0940 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0905\u091a\u094d\u091b\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0930\u0916\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0909\u092a\u0915\u0930\u0923<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938<\/h4>\n\n\n\n<p>\u0938\u092d\u0940 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902, \u091a\u093f\u092a\u094d\u0938 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964  \u0938\u093e\u092b \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964  \u0915\u093f\u0938\u0940 \u092d\u0940 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u092c\u0941\u0936\u093f\u0902\u0917 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u092c\u0926\u0932\u0947\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0936\u0940\u0924\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u0940<\/h4>\n\n\n\n<p>\u0915\u0942\u0932\u093f\u0902\u0917 \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 \u0930\u0941\u0915\u093e\u0935\u091f, \u0930\u093f\u0938\u093e\u0935 \u092f\u093e \u091f\u0942\u091f\u0947 \u092a\u0902\u0916\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0930\u0947\u0921\u093f\u090f\u091f\u0930 \u0914\u0930 \u0915\u0942\u0932\u093f\u0902\u0917 \u092b\u093f\u0928 \u0938\u093e\u092b \u0914\u0930 \u092e\u0932\u092c\u093e-\u092e\u0941\u0915\u094d\u0924 \u0939\u094b\u0902\u0964 \u090f\u0915 \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u0930\u094d\u092f\u0930\u0924 \u0915\u0942\u0932\u093f\u0902\u0917 \u0938\u093f\u0938\u094d\u091f\u092e \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u092f\u093e\u0926 \u0930\u0916\u0947\u0902:<\/strong> \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u091a\u093e\u0932\u0942 \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0935\u093f\u0915\u0943\u0924 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/h3>\n\n\n\n<p>\u0906\u092a \u0905\u092a\u0928\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u0936\u0941\u0930\u0941\u0906\u0924 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u0947 \u0938\u0947 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u091f\u0942\u091f\u0947 \u0924\u093e\u0930 \u092f\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0916\u0930\u093e\u092c \u091c\u094b\u0921\u093c \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0938 \u0915\u093e\u0930\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u0906\u092a \u0921\u093f\u091c\u093f\u091f\u0932 \u0932\u094b-\u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0947\u0902\u0938 \u0913\u0939\u092e\u092e\u0940\u091f\u0930 (DLRO) \u092f\u093e \u0907\u0938\u0940 \u0924\u0930\u0939 \u0915\u0947 \u0915\u093f\u0938\u0940 \u0909\u092a\u0915\u0930\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0938\u092c\u0938\u0947 \u092a\u0939\u0932\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u094d\u0930\u094b\u0924 \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930\u0947\u0902\u0964 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0932\u0940\u0921\u094d\u0938 \u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902\u0964 \u090f\u0915 \u091b\u094b\u091f\u093e \u0921\u0940\u0938\u0940 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u092e\u093e\u092a\u0947\u0902\u0964 \u0909\u092a\u0915\u0930\u0923 \u0913\u092e \u0915\u0947 \u0928\u093f\u092f\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u091a\u0930\u0923:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0935\u093f\u0939\u0940\u0928 \u0914\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u091f\u0947\u0938\u094d\u091f \u0932\u0940\u0921\u094d\u0938 \u0915\u094b \u0938\u0939\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902\u0964.<\/p><\/li><li><p>\u092e\u093e\u0928 \u0915\u094b \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0930\u0940\u0921\u093f\u0902\u0917 \u0915\u094b \u0938\u094d\u0925\u093f\u0930 \u0939\u094b\u0928\u0947 \u0926\u0947\u0902\u0964.<\/p><\/li><li><p>\u0905\u092a\u0928\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u092e\u0947\u0936\u093e \u0938\u092d\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938\u2014\u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915, \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0914\u0930 \u092f\u0926\u093f \u092e\u094c\u091c\u0942\u0926 \u0939\u094b \u0924\u094b \u0924\u0943\u0924\u0940\u092f\u0915\u2014\u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902, \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0947 \u0938\u093e\u0925 \u092c\u0926\u0932\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u0928 \u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u0915\u0941\u0902\u0921\u0932 \u092f\u093e \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u0906\u092a\u0915\u094b \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u092e\u0947\u0917\u0930)<\/h3>\n\n\n\n<p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/a>, \u091c\u093f\u0938\u0947 \u0905\u0915\u094d\u0938\u0930 \u201c\u092e\u0947\u0917\u0930 \u091f\u0947\u0938\u094d\u091f\u201d \u0915\u0939\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u092c\u0940\u091a \u0914\u0930 \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0924\u0925\u093e \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0947 \u092c\u0940\u091a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a \u092e\u0947\u0917\u093e\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0905\u091a\u094d\u091b\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0914\u0930 \u0928\u092e\u0940 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0947 \u0938\u092d\u0940 \u092c\u093e\u0939\u0930\u0940 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902\u0964 \u092e\u0947\u0917\u093e\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u094b \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0914\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0947 \u092c\u0940\u091a \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902\u0964 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 500V, 1000V, \u092f\u093e 2500V) \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902 \u0914\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u0928 \u092a\u0922\u093c\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u0916\u094d\u092f \u092c\u093f\u0902\u0926\u0941:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0909\u091a\u094d\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u0938\u0948\u0915\u0921\u093c\u094b\u0902 \u092e\u0947\u0917\u093e\u0913\u092e \u0915\u0940 \u0938\u0940\u092e\u093e \u092e\u0947\u0902) \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0905\u091a\u094d\u091b\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928\u0964.<\/p><\/li><li><p>\u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0928\u092e\u0940, \u0917\u0902\u0926\u0917\u0940 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0924\u093e\u092a\u092e\u093e\u0928 \u0914\u0930 \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964 \u0924\u093e\u092a\u092e\u093e\u0928 \u0914\u0930 \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e \u092c\u0922\u093c\u0928\u0947 \u092a\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0918\u091f\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0907\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0939\u093f\u0938\u094d\u0938\u0947 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u0906\u092a\u0915\u094b \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924<\/h3>\n\n\n\n<p>\u091f\u0930\u094d\u0928 \u0930\u0947\u0936\u093f\u092f\u094b \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0914\u0930 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0915\u0941\u0902\u0921\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0905\u0928\u0941\u092a\u093e\u0924 \u0907\u0915\u093e\u0908 \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0942\u092a\u093e\u0902\u0924\u0930\u0923 \u0915\u094b \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0938 \u091c\u093e\u0901\u091a \u0915\u0947 \u0932\u093f\u090f \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u091f\u0930\u094d\u0928 \u0930\u0947\u0936\u093f\u092f\u094b (TTR) \u091f\u0947\u0938\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091a\u0932\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, TTR \u091f\u0947\u0938\u094d\u091f\u0930 \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0914\u0930 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0915\u0941\u0902\u0921\u0932 \u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902\u0964 \u091f\u0947\u0938\u094d\u091f\u0930 \u090f\u0915 \u0915\u0941\u0902\u0921\u0932 \u092a\u0930 \u091c\u094d\u091e\u093e\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0926\u0942\u0938\u0930\u0947 \u0915\u0941\u0902\u0921\u0932 \u092a\u0930 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u092e\u093e\u092a\u0924\u093e \u0939\u0948\u0964 \u092b\u093f\u0930 \u092f\u0939 \u0909\u092a\u0915\u0930\u0923 \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0943\u0925\u0915 \u0939\u0948 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0939\u0948\u0964.<\/p><\/li><li><p>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 TTR \u091f\u0947\u0938\u094d\u091f\u0930 \u0915\u094b \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0938\u092d\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0938\u0902\u092f\u094b\u091c\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u092a\u093e\u0924 \u092e\u093e\u092a\u0947\u0902\u0964.<\/p><\/li><li><p>\u092e\u093e\u092a\u0947 \u0917\u090f \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u092e\u093e\u0928 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u0938\u0939\u0940 \u0915\u0941\u0902\u0921\u0932 \u0905\u0928\u0941\u092a\u093e\u0924 \u092f\u0939 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0905\u092a\u0947\u0915\u094d\u0937\u093f\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0917\u093e\u0964 \u0905\u0938\u0902\u0917\u0924\u093f \u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u0915\u0941\u0902\u0921\u0932, \u0917\u0932\u0924 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u092f\u093e\u0926 \u0930\u0916\u0947\u0902:<\/strong> \u092f\u0926\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092e\u0947\u0902 \u091f\u0948\u092a \u091a\u0947\u0902\u091c\u0930\u094d\u0938 \u0939\u0948\u0902, \u0924\u094b \u0939\u092e\u0947\u0936\u093e \u0938\u092d\u0940 \u091f\u0948\u092a \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u0907\u0938\u0938\u0947 \u0938\u092d\u0940 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0909\u091a\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u092f\u0947 \u0924\u0940\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u2014\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0914\u0930 \u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924\u2014\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091c\u093e\u0902\u091a\u094b\u0902 \u0915\u093e \u0906\u0927\u093e\u0930 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0906\u092a\u0915\u094b \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0916\u093e\u092e\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0932\u094b\u0921-\u0939\u093e\u0928\u093f \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0926\u0915\u094d\u0937\u0924\u093e \u0915\u094b \u0938\u092e\u091d\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0938\u0915\u0947 \u0932\u094b\u0921-\u0932\u0949\u0938 \u0915\u094b \u092e\u093e\u092a\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u0932\u094b\u0921-\u0932\u0949\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u0939 \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u091c\u092c \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0905\u092a\u0928\u093e \u0930\u0947\u091f\u0947\u0921 \u0932\u094b\u0921 \u0935\u0939\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0924\u094b \u0935\u0939 \u0915\u093f\u0924\u0928\u0940 \u090a\u0930\u094d\u091c\u093e \u0917\u0930\u094d\u092e\u0940 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0916\u094b \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0947\u0917\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u0938\u092e\u0917\u094d\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0932\u094b\u0921-\u0932\u0949\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u094d\u0930\u094b\u0924 \u0938\u0947 \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u093e\u0935\u0930 \u0932\u0949\u0938 \u0915\u094b \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938 \u0932\u0949\u0938 \u0915\u094b \u201c\u0915\u0949\u092a\u0930 \u0932\u0949\u0938\u201d \u0915\u0939\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092f\u0939 \u092e\u0941\u0916\u094d\u092f\u0924\u0903 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u092e\u094c\u091c\u0942\u0926 \u0924\u093e\u0902\u092c\u0947 \u0915\u0940 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u0938\u0947 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u092f\u0939 \u0915\u094d\u092f\u094b\u0902 \u092e\u093e\u092f\u0928\u0947 \u0930\u0916\u0924\u093e \u0939\u0948:<\/strong> \u0932\u094b\u0921-\u0939\u093e\u0928\u093f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0926\u0915\u094d\u0937\u0924\u093e \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0924\u094d\u092f\u0902\u0924 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0964 \u092f\u0939 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930 \u0932\u094b\u0921 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u0941\u0932 \u0939\u093e\u0928\u093f\u092f\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0928 \u0939\u093e\u0928\u093f\u092f\u094b\u0902 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0917\u0930\u094d\u092e\u0940 \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0915\u0947, \u0906\u092a\u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u0906\u0935\u0936\u094d\u092f\u0915 \u091c\u093e\u0928\u0915\u093e\u0930\u0940 \u092e\u093f\u0932\u0924\u0940 \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<p><strong>\u0932\u094b\u0921-\u0939\u093e\u0928\u093f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u091a\u0930\u0923:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0914\u0930 \u092a\u0943\u0925\u0915 \u0939\u0948\u0964.<\/p><\/li><li><p>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0914\u0930 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0915\u0941\u0902\u0921\u0932 \u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902\u0964.<\/p><\/li><li><p>\u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0924\u0925\u093e \u0936\u0915\u094d\u0924\u093f \u0939\u093e\u0928\u093f \u092e\u093e\u092a\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0905\u092a\u0947\u0915\u094d\u0937\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u093e\u0928\u093f \u092e\u093f\u0932\u0924\u0940 \u0939\u0948, \u0924\u094b \u0906\u092a\u0915\u0947 \u092a\u093e\u0938 \u0916\u0930\u093e\u092c \u0938\u0902\u092a\u0930\u094d\u0915, \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0935\u093f\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092f\u093e \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0926\u094b\u0937 \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0939\u091a\u093e\u0928 \u0906\u092a\u0915\u094b \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0926\u0915\u094d\u0937\u0924\u093e \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0932\u0940\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0915\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u091f\u0948\u0902\u0915\u094b\u0902 \u0914\u0930 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0930\u093f\u0938\u093e\u0935 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0930\u093f\u0938\u093e\u0935 \u0938\u0947 \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917, \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u092e\u0924\u093e \u092e\u0947\u0902 \u0915\u092e\u0940 \u0914\u0930 \u092f\u0939\u093e\u0902 \u0924\u0915 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0906\u092a \u0930\u093f\u0938\u093e\u0935 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0908 \u0924\u0930\u0940\u0915\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923:<\/strong> \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u092c\u094b\u0932\u094d\u091f \u0914\u0930 \u0917\u0948\u0938\u094d\u0915\u0947\u091f\u094d\u0938 \u0915\u0940 \u0909\u091a\u093f\u0924 \u0938\u0902\u092a\u0940\u0921\u093c\u0928 \u0914\u0930 \u091f\u0949\u0930\u094d\u0915 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p><strong>\u0905\u0935\u0930\u0915\u094d\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923:<\/strong> \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b \u0930\u0939\u0947 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u091c\u094b \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p><strong>\u0938\u093e\u092b \u0915\u0930\u0928\u0947 \u0915\u0947 \u0924\u0930\u0940\u0915\u0947:<\/strong> \u091a\u0930\u0923-\u0938\u0947-\u092d\u0942\u092e\u093f \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0924\u0939\u094b\u0902 \u0915\u094b \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0938\u093e\u092b \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p><strong>\u092a\u093e\u0935\u0930 \u092b\u0948\u0915\u094d\u091f\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923:<\/strong> \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0914\u0930 \u0930\u093f\u0938\u093e\u0935 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u092e\u093e\u092a\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0906\u092a \u0935\u093f\u0936\u0947\u0937 \u0915\u093f\u091f, \u091c\u0948\u0938\u0947 Duromar\u00ae \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0932\u0940\u0915 \u0905\u0930\u0947\u0938\u094d\u091f \u0915\u093f\u091f, \u0915\u093e \u092d\u0940 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u0915\u093f\u091f \u091a\u093e\u0932\u0942 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0930\u093f\u0938\u093e\u0935 \u0915\u094b \u092c\u0902\u0926 \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948 \u092c\u093f\u0928\u093e \u0909\u0928\u094d\u0939\u0947\u0902 \u092c\u0902\u0926 \u0915\u093f\u090f\u0964 \u092f\u0939 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0938\u0942\u0916\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0949\u0932\u093f\u092e\u0930 \u0914\u0930 \u0938\u093f\u0930\u0947\u092e\u093f\u0915-\u092a\u094d\u0930\u092c\u0932\u093f\u0924 \u092a\u0941\u091f\u094d\u091f\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0930\u093f\u0938\u093e\u0935-\u092a\u094d\u0930\u0935\u0923 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u094b \u0936\u0940\u0918\u094d\u0930\u0924\u093e \u0938\u0947 \u0920\u0940\u0915 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0906\u092a\u0915\u094b \u091c\u094b \u092d\u0940 \u0930\u093f\u0938\u093e\u0935 \u092e\u093f\u0932\u0947, \u0909\u0938\u0915\u093e \u0938\u094d\u0925\u093e\u0928 \u0914\u0930 \u0906\u0915\u093e\u0930 \u0939\u092e\u0947\u0936\u093e \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u092c\u0921\u093c\u0947 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u0938\u093e\u0935\u094b\u0902 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0920\u0940\u0915 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0935\u093f\u0926\u094d\u092f\u0941\u0924\u0930\u094b\u0927\u0940 \u0936\u0915\u094d\u0924\u093f<\/h3>\n\n\n\n<p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u092f\u0939 \u0926\u0930\u094d\u0936\u093e\u0924\u0940 \u0939\u0948 \u0915\u093f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092c\u093f\u0928\u093e \u091f\u0942\u091f\u0947 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u0915\u093f\u0924\u0928\u093e \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0938\u093e\u092e\u0928\u093e \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0947\u0932 \u0915\u0947 \u0932\u093f\u090f, \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0932\u0917\u092d\u0917 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0906\u0907\u0938\u094b\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <strong>\u092a\u094d\u0930\u0924\u093f \u092e\u093f\u0932\u0940\u092e\u0940\u091f\u0930 30 \u0915\u093f\u0932\u094b\u0935\u094b\u0932\u094d\u091f<\/strong>. \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0906\u092a\u0915\u094b \u0915\u0947 \u092e\u093e\u0928\u094b\u0902 \u0915\u0940 \u0924\u0932\u093e\u0936 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 <strong>\u092a\u094d\u0930\u0924\u093f \u092e\u093f\u0932\u0940\u092e\u0940\u091f\u0930 50 \u0915\u093f\u0932\u094b\u0935\u094b\u0932\u094d\u091f<\/strong> \u092f\u093e \u0909\u0938\u0938\u0947 \u0905\u0927\u093f\u0915\u0964 \u092f\u0947 \u092e\u093e\u0928 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0918\u091f\u0928 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0938\u094d\u091f\u094d\u0930\u0947\u0902\u0925 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u0916\u094d\u092f \u092c\u093f\u0902\u0926\u0941:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0938\u0947 \u0924\u0947\u0932 \u0915\u093e \u0928\u092e\u0942\u0928\u093e \u090f\u0915\u0924\u094d\u0930 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0928\u092e\u0942\u0928\u0947 \u092a\u0930 \u092c\u0922\u093c\u0924\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0938\u094d\u091f\u094d\u0930\u0947\u0902\u0925 \u091f\u0947\u0938\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u0930\u093f\u0923\u093e\u092e \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u093e\u0928\u0915 \u092e\u093e\u0928 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0915\u092e \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0924\u0947\u0932 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0928\u092e\u0940 \u092f\u093e \u0915\u0923 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u092f\u0939 \u0906\u0935\u0936\u094d\u092f\u0915 \u092e\u093e\u0928\u0915 \u092a\u0942\u0930\u093e \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u093e \u0939\u0948 \u0924\u094b \u0924\u0947\u0932 \u0915\u094b \u092c\u0926\u0932\u0947\u0902 \u092f\u093e \u0909\u0938\u0915\u093e \u0909\u092a\u091a\u093e\u0930 \u0915\u0930\u0947\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >PUL \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b PUL (\u092a\u094d\u0930\u0924\u093f \u0907\u0915\u093e\u0908 \u0930\u093f\u0938\u093e\u0935) \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u092e\u093e\u0928 \u0906\u092a\u0915\u094b \u092c\u0924\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092e\u0947\u0902 \u0907\u0938\u0915\u0940 \u0930\u0947\u091f\u0947\u0921 \u092e\u093e\u0928 \u0915\u0947 \u092e\u0941\u0915\u093e\u092c\u0932\u0947 \u0915\u093f\u0924\u0928\u093e \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0939\u0948\u0964 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930 \u0905\u0915\u094d\u0938\u0930 \u0907\u0938\u0947 \u201c\u092a\u094d\u0930\u0924\u093f\u0936\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e\u201d \u092f\u093e \u201c%Z\u201d \u0915\u0939\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u092f\u0939 \u0938\u0902\u0916\u094d\u092f\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0928\u0947\u092e\u092a\u094d\u0932\u0947\u091f \u092a\u0930 \u092a\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0926\u094d\u0935\u093e\u0930\u093e \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0928\u0947 \u0914\u0930 \u0905\u0928\u094d\u092f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0932\u094b\u0921 \u0938\u093e\u091d\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u0942\u092e\u093f\u0915\u093e \u0928\u093f\u092d\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >PUL \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0915\u094d\u092f\u093e \u0939\u0948?<\/h4>\n\n\n\n<p>PUL \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0932\u0940\u0915\u0947\u091c \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0915\u093e \u0909\u0938\u0915\u0947 \u0906\u0927\u093e\u0930 \u092e\u093e\u0928 \u0938\u0947 \u0905\u0928\u0941\u092a\u093e\u0924 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0907\u0938\u0947 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f\u0936\u0924 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0926\u0947\u0916\u0924\u0947 \u0939\u0948\u0902\u0964 \u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, \u092f\u0926\u093f \u0915\u093f\u0938\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e 5% \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0939\u0948, \u0924\u094b \u0907\u0938\u0915\u093e \u092e\u0924\u0932\u092c \u0939\u0948 \u0915\u093f \u092a\u0942\u0930\u094d\u0923 \u092d\u093e\u0930 \u092a\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e 5% \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> PUL \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0906\u092a\u0915\u094b \u092f\u0939 \u0905\u0928\u0941\u092e\u093e\u0928 \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0905\u092a\u0928\u0940 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0927\u093e\u0930\u093e \u0935\u0939\u0928 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0915\u093f\u0924\u0928\u093e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u0939\u094b\u0917\u093e\u0964 \u092f\u0939 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u0915\u094b \u092d\u0940 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >PUL \u0915\u094d\u092f\u094b\u0902 \u092e\u093e\u092f\u0928\u0947 \u0930\u0916\u0924\u093e \u0939\u0948?<\/h4>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0915\u0908 \u0915\u093e\u0930\u0923\u094b\u0902 \u0938\u0947 PUL \u092e\u093e\u0928 \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0941\u0930\u0915\u094d\u0937\u093e:<\/strong> \u0909\u091a\u094d\u091a PUL \u092e\u093e\u0928 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u094b \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0914\u0930 \u0921\u093e\u0909\u0928\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0928\u093f\u092f\u092e\u0928:<\/strong> \u0928\u093f\u092e\u094d\u0928 PUL \u092e\u093e\u0928 \u092c\u0947\u0939\u0924\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0928\u093f\u092f\u092e\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0932\u094b\u0921 \u092c\u0926\u0932\u0928\u0947 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0927\u093f\u0915 \u0938\u094d\u0925\u093f\u0930 \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p><strong>\u0938\u092e\u093e\u0902\u0924\u0930 \u0938\u0902\u091a\u093e\u0932\u0928:<\/strong> \u092f\u0926\u093f \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u092e\u0947\u0902 \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0909\u0928\u0915\u0947 PUL \u092e\u093e\u0928\u094b\u0902 \u0915\u093e \u0928\u093f\u0915\u091f\u0924\u093e \u0938\u0947 \u092e\u0947\u0932 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0938\u0902\u0917\u0924 \u092e\u093e\u0928 \u0905\u0938\u092e\u093e\u0928 \u0932\u094b\u0921 \u0935\u093f\u092d\u093e\u091c\u0928 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u0926\u093f\u0916\u093e\u0924\u0940 \u0939\u0948 \u0915\u093f PUL \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u0915\u0948\u0938\u0947 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>PUL \u092e\u093e\u0928 (%)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0926\u094b\u0937 \u0927\u093e\u0930\u093e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0928\u093f\u092f\u092e\u0928<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0938\u092e\u093e\u0902\u0924\u0930 \u0938\u0902\u091a\u093e\u0932\u0928<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u092e\u094d\u0928 (2-4%)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u091a\u094d\u091b\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u091f\u0940\u0915 \u092e\u093f\u0932\u093e\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0927\u094d\u092f\u092e (5-7%)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0927\u094d\u092f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0927\u094d\u092f\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u093f\u0932\u093e\u0928 \u0915\u0930\u0928\u093e \u0906\u0938\u093e\u0928<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0909\u091a\u094d\u091a (8%+)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u092e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0917\u0930\u0940\u092c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u093e\u091d\u093e \u0915\u0930\u0928\u0947 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0906\u092a PUL \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0948\u0938\u0947 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902?<\/h4>\n\n\n\n<p>\u0906\u092a PUL \u092e\u093e\u0928 \u0915\u094b \u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0915\u0947 \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0947 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092d\u0940 \u0915\u0939\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0907\u0938\u0947 \u0907\u0938 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u092a\u0943\u0925\u0915 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0915\u0941\u0902\u0921\u0932\u0940 \u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0915\u0930 \u0926\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0915\u0941\u0902\u0921\u0932\u0940 \u092a\u0930 \u0928\u093f\u092e\u094d\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b\u0928\u0947 \u0924\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092c\u0922\u093c\u093e\u090f\u0901\u0964.<\/p><\/li><li><p>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0927\u093e\u0930\u093e \u0915\u094b \u092e\u093e\u092a\u0947\u0902\u0964.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u0906\u092a \u0907\u0938 \u0938\u0942\u0924\u094d\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<pre class=\"wp-block-code\">\n<code>%Z = (\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \/ \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c) \u00d7 100\n<\/code><\/pre>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092e\u093e\u092a\u0947 \u0917\u090f PUL \u092e\u093e\u0928 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u092e\u093e\u0928 \u0938\u0947 \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u092e\u093e\u092a\u093e \u0917\u092f\u093e \u092e\u093e\u0928 \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u092f\u093e \u092c\u0939\u0941\u0924 \u0915\u092e \u0939\u0948, \u0924\u094b \u0938\u0902\u092d\u0935\u0924\u0903 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092e\u0947\u0902 \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u093e \u0915\u094d\u092f\u093e \u092e\u0924\u0932\u092c \u0939\u0948?<\/h4>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a\u0915\u0947 \u092e\u093e\u092a\u0947 \u0917\u090f PUL \u0928\u093e\u092e\u092a\u091f\u094d\u091f\u093f\u0915\u093e \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u094d\u0935\u0938\u094d\u0925 \u0939\u0948\u0964 \u092f\u0926\u093f \u092e\u093e\u0928 \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u0939\u0948, \u0924\u094b \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 \u0915\u093f \u0915\u0941\u0902\u0921\u0932 \u092e\u0947\u0902 \u0936\u0949\u0930\u094d\u091f \u0939\u094b \u092f\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0922\u0940\u0932\u0947 \u0939\u094b\u0902\u0964 \u092f\u0926\u093f \u092e\u093e\u0928 \u092c\u0939\u0941\u0924 \u0915\u092e \u0939\u0948, \u0924\u094b \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 \u0915\u093f \u0915\u094b\u0908 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u091c\u0941\u0921\u093c\u0940 \u0928 \u0939\u094b \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0937 \u0939\u094b\u0964.<\/p>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u092e\u0947\u0902 PUL \u092e\u093e\u0928 \u0926\u0930\u094d\u091c \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938\u0938\u0947 \u0906\u092a\u0915\u094b \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u092e\u093f\u0932\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092f\u093e\u0926 \u0930\u0916\u0928\u0947 \u092f\u094b\u0917\u094d\u092f \u092e\u0941\u0916\u094d\u092f \u092c\u093f\u0902\u0926\u0941:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PUL \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0928\u093f\u092f\u092e\u0928 \u0914\u0930 \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u091c\u093e\u0902\u091a \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0939\u092e\u0947\u0936\u093e PUL \u092e\u093e\u0928 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924, \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0914\u0930 \u0915\u0941\u0936\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u092f\u093e\u0926 \u0930\u0916\u0947\u0902:<\/strong> \u0938\u091f\u0940\u0915 PUL \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0938\u094d\u0925\u093f\u0930 \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b.webp\" alt=\"\u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923\" class=\"wp-image-1587\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/61d44242d9aa4841a0d05de5b705039b-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u091b\u0935\u093f \u0938\u094d\u0930\u094b\u0924: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">\u092a\u0947\u0915\u094d\u0938\u0932\u094d\u0938<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091c\u093e\u0901\u091a \u0915\u0930\u0928\u0940 \u0939\u094b\u0917\u0940\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0924\u0947\u0932<\/a> \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0926\u094c\u0930\u093e\u0928\u0964 \u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0906\u092a\u0915\u094b \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0914\u0930 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0917\u0948\u0938\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u0947\u0932 \u0915\u0940 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u0928\u092e\u0940 \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091a\u0930\u0923 \u0906\u092a\u0915\u094b \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u0947\u0939\u0924 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0918\u0941\u0932\u0940 \u0939\u0941\u0908 \u0917\u0948\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/h3>\n\n\n\n<p>\u0918\u0941\u0932\u0940 \u0939\u0941\u0908 \u0917\u0948\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 (DGA) \u0906\u092a\u0915\u094b \u092c\u0924\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u094d\u092f\u093e \u0939\u094b \u0930\u0939\u093e \u0939\u0948\u0964 \u091c\u092c \u0926\u094b\u0937 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0924\u0947\u0932 \u092e\u0947\u0902 \u0917\u0948\u0938\u0947\u0902 \u092c\u0928\u0924\u0940 \u0939\u0948\u0902\u0964 \u0906\u092a \u0924\u0947\u0932 \u0915\u093e \u0928\u092e\u0942\u0928\u093e \u090f\u0915\u0924\u094d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0907\u0928 \u0917\u0948\u0938\u094b\u0902 \u0915\u094b \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u0909\u092a\u0915\u0930\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0917\u0948\u0938 \u090f\u0915 \u0905\u0932\u0917 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u0940 \u0913\u0930 \u0938\u0902\u0915\u0947\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u093e\u0901 \u090f\u0915 \u0924\u093e\u0932\u093f\u0915\u093e \u0939\u0948 \u091c\u094b \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0917\u0948\u0938\u094b\u0902 \u0914\u0930 \u0909\u0928\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u092a\u0930 \u092a\u094d\u0930\u092d\u093e\u0935 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0917\u0948\u0938<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0915\u093e \u0938\u0902\u0915\u0947\u0924<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0907\u0921\u094d\u0930\u094b\u091c\u0928 (H\u2082)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0924\u0928\u093e\u0935 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092e\u0940\u0925\u0947\u0928 (CH\u2084)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0938\u094d\u0924\u0930 \u092a\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u092f\u093e \u0930\u0915\u094d\u0924 \u092a\u0930\u093f\u0938\u0902\u091a\u0930\u0923 \u092e\u0947\u0902 \u0915\u092e\u0940 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0925\u0947\u0928 (C\u2082H\u2086)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0947\u0932 \u0915\u0947 \u0928\u093f\u092e\u094d\u0928-\u0924\u093e\u092a\u092e\u093e\u0928 \u0925\u0930\u094d\u092e\u0932 \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0925\u093e\u0907\u0932\u0940\u0928 (C\u2082H\u2084)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0917\u0902\u092d\u0940\u0930 \u0924\u093e\u092a\u0940\u092f \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 300\u00b0C \u0938\u0947 \u090a\u092a\u0930\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u090f\u0938\u093f\u091f\u093f\u0932\u0940\u0928 (C\u2082H\u2082)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>700\u00b0C \u0938\u0947 \u090a\u092a\u0930, \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u091c\u0948\u0938\u0940 \u0909\u091a\u094d\u091a-\u090a\u0930\u094d\u091c\u093e \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u092c\u0928 \u092e\u094b\u0928\u094b\u0911\u0915\u094d\u0938\u093e\u0907\u0921 (CO)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u0939 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u0947 \u0924\u093e\u092a\u0940\u092f \u0905\u092a\u0918\u091f\u0928 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u092c\u0928 \u0921\u093e\u0907\u0911\u0915\u094d\u0938\u093e\u0907\u0921 (CO\u2082)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u0939 \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u0938\u0947\u0932\u094d\u092f\u0942\u0932\u094b\u091c\u093c \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093f\u0924\u0928\u0940 \u0916\u0930\u093e\u092c \u0939\u094b \u0917\u0908 \u0939\u0948\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u090f\u0938\u093f\u091f\u0940\u0932\u0940\u0928 \u092f\u093e \u090f\u0925\u093f\u0932\u0940\u0928 \u0915\u0947 \u0909\u091a\u094d\u091a \u0938\u094d\u0924\u0930 \u0915\u093e \u092e\u0924\u0932\u092c \u0939\u0948 \u0915\u093f \u0906\u092a\u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0917\u0948\u0938\u0947\u0902 \u0905\u0915\u094d\u0938\u0930 \u0917\u0902\u092d\u0940\u0930 \u0916\u0930\u093e\u092c\u0940 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0947\u0932 \u0915\u0940 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0924\u093e\u0915\u093f \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b \u0938\u0915\u0947 \u0915\u093f \u092f\u0939 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u0916\u093f\u0932\u093e\u092b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0907\u0938 \u0915\u093e\u092e \u0915\u0947 \u0932\u093f\u090f \u0906\u092a \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c (BDV) \u091f\u0947\u0938\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u0924\u0947\u0932 \u0935\u093f\u092b\u0932 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u093f\u0924\u0928\u093e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0939\u0928 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0947\u0932 \u0915\u0947 \u0932\u093f\u090f \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 BDV \u092e\u093e\u0928 \u0939\u0948 <strong>30 \u0915\u093f\u0932\u094b\u0935\u094b\u0932\u094d\u091f<\/strong>. \u092f\u0939 \u092e\u093e\u0928 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938, \u091c\u093f\u0928\u092e\u0947\u0902 11 kV, 22 kV \u0914\u0930 132 kV \u0938\u093f\u0938\u094d\u091f\u092e \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902, \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u093e\u0928 \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>IEC \u092e\u093e\u0928\u0915 \u0915\u0939\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0947\u0932 \u0915\u093e \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u092d\u0940 \u092d\u0940 \u0928\u0940\u091a\u0947 \u0928\u0939\u0940\u0902 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 <strong>30 \u0915\u093f\u0932\u094b\u0935\u094b\u0932\u094d\u091f<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u092f\u0926\u093f \u0924\u0947\u0932 \u0907\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u0905\u0938\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0907\u0938\u092e\u0947\u0902 \u0928\u092e\u0940 \u092f\u093e \u0917\u0902\u0926\u0917\u0940 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0928\u093e \u092f\u093e \u092c\u0926\u0932\u0928\u093e \u0939\u094b\u0917\u093e\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u092e\u0947\u0902 BDV \u092e\u093e\u0928 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u0915\u092e BDV \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0924\u0947\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0928\u0939\u0940\u0902 \u0930\u0916 \u0938\u0915\u0924\u093e\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e<\/h3>\n\n\n\n<p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0924\u0947\u0932 \u092e\u0947\u0902 \u0928\u092e\u0940<\/a> \u092f\u0939 \u0915\u0908 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092a\u093e\u0928\u0940 \u0924\u0947\u0932 \u0915\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f \u0915\u0930\u0928\u0947 \u0915\u0940 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u094b \u0915\u092e \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0915\u093e\u0917\u091c\u093c\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u092d\u0940 \u0915\u092e\u091c\u094b\u0930 \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0928\u092e\u0940 \u0924\u0947\u0932 \u0915\u0947 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0917\u0941\u0923\u094b\u0902 \u0915\u094b \u0915\u092e \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u092e \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0909\u091a\u094d\u091a \u091c\u0932 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0938\u0947\u0932\u094d\u092f\u0942\u0932\u094b\u091c\u093c \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u094b \u0915\u092e \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0938\u0947 \u091f\u0942\u091f-\u092b\u0942\u091f \u0915\u093e \u0916\u0924\u0930\u093e \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u091c\u0932 \u0905\u0923\u0941 \u0938\u0947\u0932\u094d\u092f\u0942\u0932\u094b\u091c\u093c \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u092d\u093e\u091c\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u094b \u0924\u0947\u091c \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928 \u0915\u094b \u0915\u092e \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0906\u092a \u0924\u0947\u0932 \u092e\u0947\u0902 \u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u091c\u093e\u0902\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u092e\u0940 \u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u0928\u092e\u0940 \u092e\u093f\u0932\u0947, \u0924\u094b \u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0915\u094b \u0938\u0941\u0916\u093e\u0928\u093e \u092f\u093e \u092c\u0926\u0932\u0928\u093e \u0939\u094b\u0917\u093e\u0964 \u0928\u092e\u0940 \u0915\u094b \u0915\u092e \u0930\u0916\u0928\u093e \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0906\u092f\u0941 \u092c\u0922\u093c\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u092f\u093e\u0926 \u0930\u0916\u0947\u0902:<\/strong> \u0928\u093f\u092f\u092e\u093f\u0924 \u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0905\u092a\u0928\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091c\u093e\u0902\u091a<\/h2>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/a> \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0935\u093e\u092a\u0938 \u0932\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u092f\u0947 \u091c\u093e\u0901\u091a \u0906\u092a\u0915\u094b \u092f\u0939 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0926\u094b\u0937\u094b\u0902 \u092f\u093e \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u094d\u0935\u092f\u0902 \u0914\u0930 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0917\u093e\u0964 \u0906\u092a \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923\u094b\u0902, \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0914\u0930 \u0905\u0932\u093e\u0930\u094d\u092e \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923<\/h3>\n\n\n\n<p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0932\u093f\u090f \u092a\u0939\u0932\u0940 \u0930\u0915\u094d\u0937\u093e \u092a\u0902\u0915\u094d\u0924\u093f \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0917\u094d\u0930\u093f\u0921 \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u092b\u094d\u092f\u0942\u091c<\/h4>\n\n\n\n<p>\u092b\u094d\u092f\u0942\u091c \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u0905\u0924\u093f-\u0927\u093e\u0930\u093e \u0938\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/a> \u0914\u0930 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f\u0964 \u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092b\u094d\u092f\u0942\u091c \u092e\u0947\u0902 \u0918\u093f\u0938\u093e\u0935, \u091c\u0902\u0917 \u092f\u093e \u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u092f\u093e \u092b\u0942\u091f\u0947 \u0939\u0941\u090f \u092b\u094d\u092f\u0942\u091c \u0915\u094b \u092c\u0926\u0932\u0947\u0902\u0964 \u0939\u092e\u0947\u0936\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0938\u0939\u0940 \u092b\u094d\u092f\u0942\u091c \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092b\u094d\u092f\u0942\u091c \u0915\u0940 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e (\u0915\u0902\u091f\u093f\u0928\u094d\u092f\u0942\u091f\u0940) \u0915\u094b \u092e\u0932\u094d\u091f\u0940\u092e\u0940\u091f\u0930 \u0938\u0947 \u091c\u093e\u0902\u091a\u0947\u0902 \u0924\u093e\u0915\u093f \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b \u0938\u0915\u0947 \u0915\u093f \u092f\u0939 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u092a\u0921\u093c\u0928\u0947 \u092a\u0930 \u0915\u093e\u092e \u0915\u0930\u0947\u0917\u093e\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u092b\u094d\u092f\u0942\u091c \u0905\u092a\u0928\u0947 \u092a\u093e\u0938 \u0930\u0916\u0947\u0902\u0964 \u0924\u094d\u0935\u0930\u093f\u0924 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0906\u092a\u093e\u0924 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0930\u093f\u0932\u0947<\/h4>\n\n\n\n<p>\u0930\u093f\u0932\u0947 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0936\u0941\u0930\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092f\u0939 \u091c\u093e\u0902\u091a\u0928\u093e \u0939\u094b\u0917\u093e \u0915\u093f \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0930\u093f\u0932\u0947 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0915\u093e\u092e \u0915\u0930 \u0930\u0939\u093e \u0939\u0948\u0964 \u0926\u094b\u0937 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0905\u0928\u0941\u0915\u0930\u0923 \u0915\u0930\u0915\u0947 \u0930\u093f\u0932\u0947 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0907\u0938\u0915\u0940 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0926\u0947\u0916\u0947\u0902\u0964 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902 \u0915\u093f \u0930\u093f\u0932\u0947 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0930\u0924\u093e \u0939\u0948 \u092f\u093e \u0905\u0932\u093e\u0930\u094d\u092e \u0938\u093f\u0917\u094d\u0928\u0932 \u092d\u0947\u091c\u0924\u093e \u0939\u0948\u0964 \u0930\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092e\u093e\u0928\u094b\u0902 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0915\u094b\u0908 \u0905\u0902\u0924\u0930 \u092e\u093f\u0932\u0947 \u0924\u094b \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092d\u0942\u092e\u093f \u0938\u0947 \u091c\u094b\u0921\u093c\u0928\u093e<\/h3>\n\n\n\n<p>\u0909\u091a\u093f\u0924 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u0943\u0925\u094d\u0935\u0940 \u092e\u0947\u0902 \u092d\u0947\u091c\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0909\u092a\u0915\u0930\u0923 \u0914\u0930 \u0932\u094b\u0917 \u0926\u094b\u0928\u094b\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0939\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928<\/h4>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u092e\u093e\u092a\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0908 \u0924\u0930\u0940\u0915\u0947 \u0906\u092a\u0915\u094b \u0910\u0938\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u0938\u0902\u092d\u093e\u0935\u094d\u092f-\u092a\u0924\u0928 \u0935\u093f\u0927\u093f:<\/strong> \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u094d\u091f\u0947\u0915 \u0915\u094b \u091c\u092e\u0940\u0928 \u092e\u0947\u0902 \u0932\u0917\u093e\u090f\u0902\u0964  \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u092e\u093e\u092a\u0947\u0902\u0964.<\/p><\/li><li><p><strong>\u0915\u094d\u0932\u0948\u092e\u094d\u092a-\u0911\u0928 \u0935\u093f\u0927\u093f:<\/strong> \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u094b \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u094d\u0932\u0948\u0902\u092a-\u0911\u0928 \u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0935\u093f\u0927\u093f \u092a\u0939\u0932\u0947 \u0938\u0947 \u0939\u0940 \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u092e\u094c\u091c\u0942\u0926 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0915\u093e\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li><li><p><strong>\u0924\u0940\u0928-\u092c\u093f\u0902\u0926\u0941 \u0935\u093f\u0927\u093f:<\/strong> \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0938\u091f\u0940\u0915 \u0930\u0942\u092a \u0938\u0947 \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0926\u0942\u0930\u0940 \u092a\u0930 \u0924\u0940\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u094d\u091f\u0947\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092e\u093e\u092a\u0940 \u0917\u0908 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0914\u0930 \u0907\u0938\u0947 \u092e\u093e\u0928\u0915 \u0938\u0940\u092e\u093e \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u091c\u094b \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 1 \u0913\u092e \u0938\u0947 \u0915\u092e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0909\u091a\u094d\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0916\u0930\u093e\u092c \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092f\u093e \u092e\u093f\u091f\u094d\u091f\u0940 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0905\u0932\u093e\u0930\u094d\u092e \u0914\u0930 \u091f\u094d\u0930\u093f\u092a<\/h3>\n\n\n\n<p>\u0905\u0932\u093e\u0930\u094d\u092e \u0914\u0930 \u091f\u094d\u0930\u093f\u092a \u0924\u0902\u0924\u094d\u0930 \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u092f\u0926\u093f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u092f\u0939 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0915\u093f \u092f\u0947 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901 \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930 \u0930\u0939\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u091f\u094d\u0930\u093f\u092a \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u0930\u094d\u092f\u0935\u0947\u0915\u094d\u0937\u0923 (TCS) \u0930\u093f\u0932\u0947 \u0939\u0930 \u0938\u092e\u092f \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093f\u092a \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>\u092f\u0926\u093f TCS \u0930\u093f\u0932\u0947 \u0915\u094b \u0916\u0941\u0932\u0947 \u0938\u0930\u094d\u0915\u093f\u091f, \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902, \u092f\u093e \u0915\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u0948\u0938\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0902 \u092a\u0924\u093e \u091a\u0932\u0924\u0940 \u0939\u0948\u0902, \u0924\u094b \u0905\u0932\u093e\u0930\u094d\u092e \u0938\u0915\u094d\u0930\u093f\u092f \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>TCS \u0930\u093f\u0932\u0947 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u091a\u093e\u0932\u0942 \u0939\u094b \u092f\u093e \u092c\u0902\u0926, \u0926\u094b\u0928\u094b\u0902 \u0939\u0940 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0928\u093f\u0930\u0902\u0924\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0924\u094d\u0930\u0941\u091f\u093f \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0905\u0928\u0941\u0915\u0930\u0923 \u0915\u0930\u0915\u0947 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0905\u0932\u093e\u0930\u094d\u092e \u0914\u0930 \u091f\u094d\u0930\u093f\u092a \u092b\u093c\u0902\u0915\u094d\u0936\u0928 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902 \u0915\u093f \u0905\u0932\u093e\u0930\u094d\u092e \u092c\u091c\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u092a\u0921\u093c\u0928\u0947 \u092a\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0947 \u0938\u0902\u0926\u0930\u094d\u092d \u0915\u0947 \u0932\u093f\u090f \u0905\u092a\u0928\u0947 \u092a\u0930\u093f\u0923\u093e\u092e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u092f\u093e\u0926 \u0930\u0916\u0947\u0902:<\/strong> \u0928\u093f\u092f\u092e\u093f\u0924 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091c\u093e\u0902\u091a \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u092e\u092f \u0930\u0939\u0924\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902 \u0914\u0930 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0930\u0916\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0930\u093f\u0915\u0949\u0930\u094d\u0921\u093f\u0902\u0917 \u092a\u0930\u093f\u0923\u093e\u092e<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u0914\u0930 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0924\u0930\u0940\u0915\u0947 \u0938\u0947 \u0926\u0930\u094d\u091c \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0938\u091f\u0940\u0915 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092d\u0940 \u092e\u093e\u092a, \u0905\u0935\u0932\u094b\u0915\u0928 \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937 \u0915\u094b \u0932\u093f\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u092e\u093e\u0928\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0932\u0949\u0917 \u092f\u093e \u0921\u093f\u091c\u093f\u091f\u0932 \u092b\u0949\u0930\u094d\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0924\u093e\u0930\u0940\u0916, \u0938\u094d\u0925\u093e\u0928 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0932\u094b\u0917\u094b\u0902 \u0915\u0947 \u0928\u093e\u092e \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902\u0964 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u093e\u090f \u0917\u090f \u0915\u093f\u0938\u0940 \u092d\u0940 \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u0940 \u0924\u0938\u094d\u0935\u0940\u0930\u0947\u0902 \u0938\u0902\u0932\u0917\u094d\u0928 \u0915\u0930\u0947\u0902\u0964 \u0905\u091a\u094d\u091b\u0940 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u093e \u0914\u0930 \u0909\u0928 \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u094b \u092a\u0939\u091a\u093e\u0928\u0928\u093e \u0906\u0938\u093e\u0928 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948 \u091c\u094b \u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0905\u092a\u0928\u0947 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u094b \u0921\u093f\u091c\u093f\u091f\u0932 \u0914\u0930 \u0915\u093e\u0917\u091c\u0940 \u0926\u094b\u0928\u094b\u0902 \u092a\u094d\u0930\u093e\u0930\u0942\u092a\u094b\u0902 \u092e\u0947\u0902 \u0930\u0916\u0947\u0902\u0964 \u0907\u0938 \u0905\u092d\u094d\u092f\u093e\u0938 \u0938\u0947 \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948 \u0915\u093f \u092f\u0926\u093f \u090f\u0915 \u0938\u0947\u091f \u0916\u094b \u091c\u093e\u090f \u0924\u094b \u0906\u092a\u0915\u0947 \u092a\u093e\u0938 \u092c\u0948\u0915\u0905\u092a \u092e\u094c\u091c\u0942\u0926 \u0930\u0939\u0947\u0917\u093e\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092e\u093e\u0928\u0915 \u0905\u0928\u0941\u092a\u093e\u0932\u0928<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0905\u092a\u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u093e \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u0940\u0915\u0930\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0905\u0902\u0924\u0930\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u092e\u093e\u0928\u0915 \u0906\u092a\u0915\u094b \u092f\u0939 \u0938\u093e\u092c\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0906\u092a\u0915\u093e \u0915\u093e\u0930\u094d\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0906\u092a\u0915\u0947 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u0940\u0915\u0930\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0938\u0939\u0940 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u0938\u0902\u0926\u0930\u094d\u092d \u0932\u0947\u0902\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u092e\u0947\u0902 \u0915\u0941\u091b \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092e\u093e\u0928\u0915 \u0926\u093f\u090f \u0917\u090f \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0906\u092a\u0915\u094b \u091c\u093e\u0928\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u092e\u093e\u0928\u0915<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u0935\u0930\u0923<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0908\u0908\u0938\u0940 \/ \u0908\u090f\u0928 61558<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u093e\u0928\u0915\u0964.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u0942\u0930\u094b\u092a\u0940\u092f \u092e\u093e\u0928\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u092e\u093e\u0923\u0940\u0915\u0930\u0923 (ENEC)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u0942\u0930\u094b\u092a\u0940\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u092a\u094d\u0930\u092e\u093e\u0923\u0928 \u091a\u093f\u0939\u094d\u0928\u0964.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0907\u0928 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a \u0905\u092a\u0928\u0940 \u0915\u0902\u092a\u0928\u0940 \u0915\u094b \u0911\u0921\u093f\u091f \u092a\u093e\u0938 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0915\u093e\u0928\u0942\u0928\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u092a \u0926\u0942\u0938\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u092d\u0940 \u0906\u0938\u093e\u0928 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u0947\u0902<\/h3>\n\n\n\n<p>\u0935\u093f\u0924\u0930\u0923 \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/dry-type-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/a>, \u0906\u092a\u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u0947\u0902 \u0926\u0947\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0947 \u0915\u0926\u092e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939\u093e\u0901 \u0915\u0941\u091b \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0915\u093e\u0930\u094d\u092f \u0926\u093f\u090f \u0917\u090f \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0906\u092a\u0915\u094b \u0938\u0941\u091d\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u092d\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u094b \u0915\u0938\u0947\u0902\u0964.<\/p><\/li><li><p>\u091c\u093e\u0901\u091a\u0947\u0902 \u0915\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923 \u0920\u0940\u0915 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0916\u0930\u093e\u092c\u0940 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li><li><p>\u0913\u0935\u0930\u0932\u094b\u0921\u093f\u0902\u0917 \u0914\u0930 \u0938\u092e\u092f \u0938\u0947 \u092a\u0939\u0932\u0947 \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u0947 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0947 \u0932\u094b\u0921 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0918\u093f\u0938\u093e\u0935, \u0924\u0947\u0932 \u0930\u093f\u0938\u093e\u0935 \u0914\u0930 \u091c\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u092e\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0906\u0915\u0932\u0928 \u0915\u0930\u0947\u0902 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/oil-immersed-transformer\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0924\u0947\u0932<\/a> \u0928\u092e\u0940, \u0905\u092e\u094d\u0932\u0940\u092f\u0924\u093e, \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0906\u0935\u0930\u094b\u0927\u0915 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0947 \u0932\u093f\u090f\u0964.<\/p><\/li><li><p>\u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u092b \u0915\u0930\u0947\u0902, \u091a\u093f\u0915\u0928\u093e\u0908 \u0932\u0917\u093e\u090f\u0901 \u0914\u0930 \u0928\u092e\u0940 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0918\u0941\u0932\u093f\u0924 \u0917\u0948\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0914\u0930 \u0925\u0930\u094d\u092e\u0932 \u0907\u092e\u0947\u091c\u093f\u0902\u0917 \u091c\u0948\u0938\u0947 \u0909\u0928\u094d\u0928\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u092c\u0936\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0938\u093e\u092b \u0930\u0916\u0947\u0902\u0964.<\/p><\/li><li><p>\u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0915\u0942\u0932\u093f\u0902\u0917 \u0938\u093f\u0938\u094d\u091f\u092e \u0913\u0935\u0930\u0939\u0940\u091f\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0920\u0940\u0915 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092e\u0947\u0902 \u0928\u092e\u0940 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u093f\u0932\u093f\u0915\u093e \u091c\u0947\u0932 \u092c\u094d\u0930\u0940\u0925\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0906\u092a\u0915\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928 \u0915\u094b \u092c\u0922\u093c\u093e\u090f\u0917\u093e \u0914\u0930 \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0947\u0917\u093e\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0923\u093e\u092e<\/h3>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u090f\u0915 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0910\u0938\u0947 \u092a\u0930\u093f\u0923\u093e\u092e \u092e\u093f\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u0905\u092a\u0947\u0915\u094d\u0937\u093f\u0924 \u092e\u093e\u0928\u094b\u0902 \u0938\u0947 \u092e\u0947\u0932 \u0928\u0939\u0940\u0902 \u0916\u093e\u0924\u0947\u0964 \u092f\u0947 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0923\u093e\u092e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 \u091b\u093f\u092a\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u0913\u0930 \u0907\u0936\u093e\u0930\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u091c\u092c \u092d\u0940 \u0906\u092a\u0915\u094b \u0915\u0941\u091b \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0926\u093f\u0916\u0947, \u0924\u094b \u0906\u092a\u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u092e\u0947\u0902 \u0915\u0941\u091b \u0938\u092c\u0938\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0923\u093e\u092e \u0914\u0930 \u0909\u0928\u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0926\u093f\u0916\u093e\u092f\u093e \u0917\u092f\u093e \u0939\u0948:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0923\u093e\u092e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0922\u0940\u0932\u0947 \u092f\u093e \u091c\u0902\u0917 \u0932\u0917\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u0938\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0926\u094b\u0937<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0926\u094b\u0937<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0936\u0940\u0924\u0932\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0915\u093e \u092a\u094d\u0930\u0935\u0947\u0936<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947 \u0909\u092a\u093e\u092f \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0942\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0926\u0942\u0937\u093f\u0924 \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0947\u0902 \u0914\u0930 \u092c\u0926\u0932\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0902\u091f\u0930\u091f\u0930\u094d\u0928 \u0936\u0949\u0930\u094d\u091f\u094d\u0938<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0906\u0917\u0947 \u0915\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092c\u0922\u093c\u0947 \u0939\u0941\u090f \u0928\u0941\u0915\u0938\u093e\u0928<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u093e\u0928\u093f\u092f\u094b\u0902 \u0915\u093e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0938\u0941\u0927\u093e\u0930\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092c\u0941\u0936\u093f\u0902\u0917 \u0926\u094b\u0937<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0916\u0930\u093e\u092c \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902 \u0914\u0930 \u092c\u0926\u0932\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u093e \u0906\u0915\u0932\u0928 \u0915\u0930\u0947\u0902 \u0914\u0930 \u092f\u0926\u093f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u092c\u0926\u0932\u0947\u0902\u0964<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0935\u093f\u0915\u0943\u0924\u093f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u0902\u0930\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0928\u0941\u0938\u093e\u0930 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902\u0964<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u091c\u092c \u0906\u092a\u0915\u094b \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0923\u093e\u092e \u092e\u093f\u0932\u0947\u0902, \u0924\u094b \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0930\u093f\u092a\u094b\u0930\u094d\u091f \u0924\u0948\u092f\u093e\u0930 \u0915\u0930\u0947\u0902\u0964 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u0940 \u0917\u0902\u092d\u0940\u0930\u0924\u093e \u091c\u093e\u0902\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0926\u093e\u0928 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0926\u094b\u0937 \u0915\u093e \u0938\u091f\u0940\u0915 \u0938\u094d\u0925\u093e\u0928 \u0916\u094b\u091c\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0924\u092f \u0915\u0930\u0947\u0902 \u0915\u093f \u0915\u094d\u092f\u093e \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0926\u094b\u0937<\/h3>\n\n\n\n<p>\u0906\u092a \u0928\u093f\u092f\u092e\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0915\u094d\u0938\u0930 \u090f\u0915 \u0939\u0940 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0940 \u0916\u093e\u092e\u093f\u092f\u093e\u0901 \u0926\u0947\u0916\u0947\u0902\u0917\u0947\u0964 \u0907\u0928 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u093e\u0928\u0928\u093e \u0906\u092a\u0915\u094b \u0936\u0941\u0930\u0941\u0906\u0924\u0940 \u091a\u0930\u0923 \u092e\u0947\u0902 \u0939\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0914\u0930 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0928\u0940\u091a\u0947 \u0926\u0940 \u0917\u0908 \u0924\u093e\u0932\u093f\u0915\u093e \u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u0923 \u0914\u0930 \u0935\u0947 \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902, \u0938\u0942\u091a\u0940\u092c\u0926\u094d\u0927 \u0939\u0948\u0902:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>92<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0905\u0924\u093f\u092d\u093e\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>30<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0930\u0947\u0916\u093e \u092e\u0947\u0902 \u0909\u091b\u093e\u0932<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>70<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u092e\u0940<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>21<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0947\u0932 \u0915\u093e \u092a\u094d\u0930\u0926\u0942\u0937\u0923<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>20<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984.webp\" alt=\"\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0938\u092c\u0938\u0947 \u0906\u092e \u0926\u094b\u0937 \u0926\u093f\u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u092c\u093e\u0930 \u091a\u093e\u0930\u094d\u091f\" class=\"wp-image-1588\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/chart_1764449712868527984-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u092c\u0938\u0947 \u0906\u092e \u0938\u092e\u0938\u094d\u092f\u093e \u0939\u0948 \u091c\u093f\u0938\u0915\u093e \u0906\u092a \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0947\u0902\u0917\u0947\u0964 \u0913\u0935\u0930\u0932\u094b\u0921\u093f\u0902\u0917 \u0914\u0930 \u0932\u093e\u0907\u0928 \u0938\u0930\u094d\u091c \u092d\u0940 \u0915\u0908 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u092e\u0940 \u0914\u0930 \u0924\u0947\u0932 \u0915\u0940 \u0938\u0902\u0926\u0942\u0937\u0923 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094b \u0915\u092e\u091c\u094b\u0930 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u091f\u0942\u091f\u0928 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a\u0915\u094b \u0905\u092a\u0928\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0907\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0940 \u0939\u092e\u0947\u0936\u093e \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/h3>\n\n\n\n<p>\u092f\u0926\u093f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0938\u092e\u0938\u094d\u092f\u093e \u092e\u093f\u0932\u0947, \u0924\u094b \u092e\u0930\u092e\u094d\u092e\u0924 \u092f\u093e \u0938\u092e\u093e\u092f\u094b\u091c\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0905\u091a\u094d\u091b\u0940 \u092a\u094d\u0930\u0925\u093e\u090f\u0901 \u0906\u092a\u0915\u094b \u092f\u0939 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0939\u0948 \u0914\u0930 \u0938\u0947\u0935\u093e \u0915\u0947 \u0932\u093f\u090f \u0924\u0948\u092f\u093e\u0930 \u0939\u0948\u0964  \u0907\u0928 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0938\u092d\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0914\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u093e \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0907\u0924\u093f\u0939\u093e\u0938 \u0930\u0916\u0947\u0902\u0964 \u092f\u0939 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0906\u092a\u0915\u094b \u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u092c\u0947\u0939\u0924\u0930 \u0928\u093f\u0930\u094d\u0923\u092f \u0932\u0947\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0935\u093e\u0930\u0902\u091f\u0940 \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u094d\u0930\u092e\u0941\u0916 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 \u092f\u0939 \u0915\u0926\u092e \u0906\u092a\u0915\u094b \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0915\u0921\u093c\u0928\u0947 \u0914\u0930 \u0920\u0940\u0915 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p><\/li><li><p>\u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0914\u0930 \u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u091c\u0948\u0938\u0947 \u092a\u094d\u0930\u092e\u0941\u0916 \u092e\u093e\u092a\u0926\u0902\u0921\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0930\u0947\u0902\u0964.<\/p><\/li><li><p>\u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0918\u0941\u0932\u093f\u0924 \u0917\u0948\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0914\u0930 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u092e\u093e\u092a\u0928 \u091c\u0948\u0938\u0947 \u0928\u093f\u0926\u093e\u0928 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092f\u0947 \u0909\u092a\u0915\u0930\u0923 \u0906\u092a\u0915\u094b \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0916\u093e\u092e\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0930\u093f\u0915\u0949\u0930\u094d\u0921-\u0915\u0940\u092a\u093f\u0902\u0917 \u0906\u092a\u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0914\u0930 \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u091a\u0930\u0923-\u0926\u0930-\u091a\u0930\u0923 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0905\u092a\u0928\u093e\u090f\u0901\u0964.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u090f\u0901<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0915\u094d\u0930\u092e<\/h3>\n\n\n\n<p>\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e \u090f\u0915 \u0938\u094d\u092a\u0937\u094d\u091f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0906\u092a\u0915\u094b \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u091a\u0930\u0923\u094b\u0902 \u0915\u094b \u091b\u094b\u0921\u093c\u0928\u0947 \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u0915\u093e\u092e \u0915\u094b \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0930\u0916\u0924\u093e \u0939\u0948\u0964 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u0936\u0941\u0930\u0942 \u0915\u0930\u0947\u0902\u0964 \u092b\u093f\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u0913\u0930 \u092c\u0922\u093c\u0947\u0902\u0964 \u0905\u0902\u0924 \u092e\u0947\u0902 \u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0914\u0930 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964 \u0906\u092a \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0917\u0924\u093f \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0915\u094d\u0930\u092e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u092c\u093e\u0939\u0930\u0940 \u0914\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0918\u091f\u0915\u094b\u0902 \u0915\u093e \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/p><\/li><li><p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u091f\u0930\u094d\u0928\u094d\u0938 \u0905\u0928\u0941\u092a\u093e\u0924)<\/p><\/li><li><p>\u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 (\u0918\u0941\u0932\u0940 \u0939\u0941\u0908 \u0917\u0948\u0938, \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0930\u094b\u0927\u0940 \u0915\u094d\u0937\u092e\u0924\u093e, \u0928\u092e\u0940 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e)<\/p><\/li><li><p>\u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091c\u093e\u0902\u091a (\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923, \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917, \u0905\u0932\u093e\u0930\u094d\u092e)<\/p><\/li>\n<\/ol>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0938\u0941\u091d\u093e\u0935:<\/strong> \u0939\u0930 \u092c\u093e\u0930 \u090f\u0915 \u0939\u0940 \u0915\u094d\u0930\u092e \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964 \u0906\u092a \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u091c\u0932\u094d\u0926\u0940 \u092a\u0915\u0921\u093c\u0947\u0902\u0917\u0947 \u0914\u0930 \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u0915\u092e \u0915\u0930\u0947\u0902\u0917\u0947\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0909\u092a\u0915\u0930\u0923 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0938\u091f\u0940\u0915 \u092a\u0930\u093f\u0923\u093e\u092e \u091a\u093e\u0939\u093f\u090f\u0964  \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f\u0947\u0921 \u0909\u092a\u0915\u0930\u0923 \u0906\u092a\u0915\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0921\u0947\u091f\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964  \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947, \u0905\u092a\u0928\u0947 \u0938\u092d\u0940 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u091c\u093e\u0902\u091a\u0947\u0902\u0964  \u0926\u093f\u0928\u093e\u0902\u0915 \u0926\u0947\u0916\u0947\u0902 \u0914\u0930 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0909\u092a\u0915\u0930\u0923 \u0906\u0935\u0936\u094d\u092f\u0915 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964  \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b \u091a\u0941\u0915\u0947 \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u092e\u093f\u0932\u0947\u0902, \u0924\u094b \u0909\u092a\u0915\u0930\u0923 \u0915\u094b \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u092d\u0947\u091c\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0924\u093e\u0932\u093f\u0915\u093e:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0909\u092a\u0915\u0930\u0923<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u0905\u0902\u0924\u0930\u093e\u0932<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0906\u0935\u0936\u094d\u092f\u0915<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u0940\u091f\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u0930 6 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0918\u0941\u092e\u093e\u0935 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u0940\u091f\u0930<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u0930 12 \u092e\u0939\u0940\u0928\u0947<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0938\u091f\u0940\u0915\u0924\u093e \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u091f\u0930\u094d\u0928 \u0905\u0928\u0941\u092a\u093e\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u0930 12 \u092e\u0939\u0940\u0928\u0947<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0924\u0947\u0932 \u092c\u0940\u0921\u0940\u0935\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0915<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0939\u0930 6 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0928\u094b\u091f:<\/strong> \u0906\u092a\u0915\u094b \u0915\u092d\u0940 \u092d\u0940 \u092c\u093f\u0928\u093e \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f \u0915\u093f\u090f \u0909\u092a\u0915\u0930\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0928\u0939\u0940\u0902 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0917\u0932\u0924 \u092e\u093e\u092a \u0917\u0932\u0924 \u0928\u093f\u0930\u094d\u0923\u092f \u0914\u0930 \u0905\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u091f\u0940\u092e \u0938\u092e\u0928\u094d\u0935\u092f<\/h3>\n\n\n\n<p>\u0905\u091a\u094d\u091b\u093e \u091f\u0940\u092e \u0938\u092e\u0928\u094d\u0935\u092f \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094b \u0905\u0927\u093f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0905\u0927\u093f\u0915 \u0915\u0941\u0936\u0932 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u0940\u092e \u0938\u0926\u0938\u094d\u092f \u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u092d\u0942\u092e\u093f\u0915\u093e\u090f\u0901 \u0938\u094c\u0902\u092a\u0947\u0902\u0964 \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0905\u092a\u0928\u0940 \u092f\u094b\u091c\u0928\u093e \u0938\u093e\u091d\u093e \u0915\u0930\u0947\u0902\u0964 \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092c\u094d\u0930\u0940\u092b\u093f\u0902\u0917 \u0906\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0938\u093e\u0925 \u092e\u0947\u0902 \u0915\u0930\u0947\u0902\u0964 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u0947\u0902 \u0930\u0939\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u0921\u093f\u092f\u094b \u092f\u093e \u092e\u094b\u092c\u093e\u0907\u0932 \u092b\u094b\u0928 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u091f\u0940\u092e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0947 \u0938\u0941\u091d\u093e\u0935:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u092a\u0930\u093f\u0923\u093e\u092e \u0926\u0930\u094d\u091c \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0935\u094d\u092f\u0915\u094d\u0924\u093f \u0928\u093f\u092f\u0941\u0915\u094d\u0924 \u0915\u0930\u0947\u0902\u0964<\/p><\/li><li><p>\u0916\u0924\u0930\u094b\u0902 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0927\u093f\u0915\u093e\u0930\u0940 \u0928\u093f\u092f\u0941\u0915\u094d\u0924 \u0915\u0930\u0947\u0902\u0964<\/p><\/li><li><p>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u092d\u0940 \u0915\u094b \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u092a\u0924\u093e \u0939\u094b\u0964<\/p><\/li><li><p>\u092a\u0942\u0930\u0940 \u091f\u0940\u092e \u0915\u0947 \u0938\u093e\u0925 \u0905\u092a\u0921\u0947\u091f \u0914\u0930 \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937 \u0938\u093e\u091d\u093e \u0915\u0930\u0947\u0902<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\ud83d\udee1\ufe0f \u091c\u092c \u0939\u0930 \u0915\u094b\u0908 \u0905\u092a\u0928\u0940 \u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930\u093f\u092f\u093e\u0901 \u0938\u092e\u091d\u0924\u093e \u0939\u0948, \u0924\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092c\u0947\u0939\u0924\u0930 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0906\u092a \u0917\u0932\u0924\u093f\u092f\u093e\u0901 \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091c\u0932\u094d\u0926\u0940 \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<p>\u0907\u0928\u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0915\u0947 \u0906\u092a \u0905\u092a\u0928\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/hi\/power-distribution-transformers\/\">\u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u090f\u0901<\/a>. \u0906\u092a \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0947\u0902\u0917\u0947, \u0938\u091f\u0940\u0915 \u0921\u0947\u091f\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0947\u0902\u0917\u0947, \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0917\u0947\u0964.<\/p>\n\n\n\n<p>\u091c\u092c \u0906\u092a \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0905\u092a\u0928\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0906\u092a\u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092e\u0942\u0932\u094d\u092f \u092e\u093f\u0932\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f, \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u0913\u0902 \u0938\u0947 \u0905\u092a\u0921\u0947\u091f \u0930\u0939\u0915\u0930, \u0906\u092a \u0905\u092a\u0928\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0905\u092a\u0928\u0940 \u091f\u0940\u092e \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u0940\u0916\u0924\u0947 \u0930\u0939\u0947\u0902 \u0914\u0930 \u0939\u092e\u0947\u0936\u093e \u0928\u0935\u0940\u0928\u0924\u092e \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e\u092a\u0942\u0930\u094d\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0906\u092a\u0915\u0940 \u092a\u094d\u0930\u0924\u093f\u092c\u0926\u094d\u0927\u0924\u093e \u090f\u0915 \u092e\u091c\u092c\u0942\u0924, \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092a\u093e\u0935\u0930 \u0917\u094d\u0930\u093f\u0921 \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0932\u093f\u090f \u0938\u092c\u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094c\u0928 \u0938\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u0939\u092e\u0947\u0936\u093e \u092a\u0939\u0932\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u092a\u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0928\u092e\u0940 \u092f\u093e \u091f\u0942\u091f-\u092b\u0942\u091f \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0905\u091a\u094d\u091b\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0906\u092a\u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u092a\u0915\u094b \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n\n\n\n<p>\u0906\u092a\u0915\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u092e \u0938\u0947 \u0915\u092e \u0938\u093e\u0932 \u092e\u0947\u0902 \u090f\u0915 \u092c\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0938\u092e\u0938\u094d\u092f\u093e \u0926\u093f\u0916\u093e\u0908 \u0926\u0947 \u092f\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0920\u094b\u0930 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930 \u0930\u0939\u093e \u0939\u094b, \u0924\u094b \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u094d\u092f\u094b\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948?<\/h3>\n\n\n\n<p>\u0924\u0947\u0932 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0906\u092a\u0915\u094b \u091b\u093f\u092a\u0940 \u0939\u0941\u0908 \u0916\u093e\u092e\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u092a \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940, \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u092f\u093e \u0928\u092e\u0940 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u094d\u0935\u091a\u094d\u091b \u0924\u0947\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935 \u092e\u093f\u0932\u0947 \u0924\u094b \u0906\u092a\u0915\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u0924\u0941\u0930\u0902\u0924 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0930\u0947\u0902\u0964 \u0930\u093f\u0938\u093e\u0935 \u0915\u093e \u0938\u094d\u0925\u093e\u0928 \u0914\u0930 \u0906\u0915\u093e\u0930 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u0930\u093f\u0938\u093e\u0935 \u0920\u0940\u0915 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0924\u0947\u0932 \u0915\u093e \u0938\u094d\u0924\u0930 \u091c\u093e\u0902\u091a\u0947\u0902\u0964 \u0930\u093f\u0938\u093e\u0935 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0914\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0915\u094d\u092f\u093e \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092f\u0941\u0915\u094d\u0924 \u0939\u094b\u0928\u0947 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u0928\u0939\u0940\u0902, \u0906\u092a\u0915\u094b \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0947 \u092a\u0939\u0932\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092f\u0939 \u0906\u092a\u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u092a\u0915\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0915\u094d\u0937\u0924\u093f \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0928\u093f\u092e\u094d\u0928 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0938\u094d\u091f\u094d\u0930\u0947\u0902\u0925 \u092e\u093e\u0928 \u0915\u093e \u0915\u094d\u092f\u093e \u0905\u0930\u094d\u0925 \u0939\u0948?<\/h3>\n\n\n\n<p>\u0928\u093f\u092e\u094d\u0928 \u092e\u093e\u0928 \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0924\u0947\u0932 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0928\u092e\u0940 \u092f\u093e \u0917\u0902\u0926\u0917\u0940 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u092a\u0915\u094b \u0924\u0947\u0932 \u0915\u094b \u0938\u093e\u092b \u092f\u093e \u092c\u0926\u0932\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0906\u092a \u0915\u0948\u0938\u0947 \u091c\u093e\u0928\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u092c\u0941\u0936\u093f\u0902\u0917 \u0915\u094b \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u0926\u0930\u093e\u0930\u0947\u0902, \u091a\u093f\u092a\u094d\u0938 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964 \u092f\u0926\u093f \u0906\u092a\u0915\u094b \u0915\u094b\u0908 \u0915\u094d\u0937\u0924\u093f \u0926\u093f\u0916\u093e\u0908 \u0926\u0947 \u0924\u094b \u092c\u0941\u0936\u093f\u0902\u0917 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u092c\u0926\u0932 \u0926\u0947\u0902\u0964 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937 \u092a\u0948\u0926\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e, \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0915\u094b \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0907\u0938 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>","protected":false},"author":3,"featured_media":1585,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-1589","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1589","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=1589"}],"version-history":[{"count":3,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1589\/revisions"}],"predecessor-version":[{"id":3517,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/1589\/revisions\/3517"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/1585"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=1589"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=1589"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=1589"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}