{"id":2118,"date":"2025-12-15T16:44:21","date_gmt":"2025-12-15T16:44:21","guid":{"rendered":"https:\/\/xbrele.com\/?p=2118"},"modified":"2026-04-07T12:32:32","modified_gmt":"2026-04-07T12:32:32","slug":"what-is-vacuum-circuit-breaker-working-principle","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/what-is-vacuum-circuit-breaker-working-principle\/","title":{"rendered":"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940) \u0915\u094d\u092f\u093e \u0939\u0948 \u0914\u0930 \u092f\u0939 \u0915\u0948\u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948?"},"content":{"rendered":"\ufeff\n<div class=\"executive-summary\">\n    <h3>\u0915\u093e\u0930\u094d\u092f\u0915\u093e\u0930\u0940 \u0938\u093e\u0930\u093e\u0902\u0936: \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0924\u094d\u0935\u0930\u093f\u0924 \u0905\u0935\u0932\u094b\u0915\u0928<\/h3>\n    <p>\n        \u0926 <strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/strong> \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0935\u0940\u0915\u0943\u0924 \u092e\u093e\u0928\u0915 \u0939\u0948, \u091c\u094b SF6 \u0914\u0930 \u0924\u0947\u0932 \u092a\u094d\u0930\u094c\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935-\u092e\u0941\u0915\u094d\u0924 \u0914\u0930 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0935\u093f\u0915\u0932\u094d\u092a \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.\n    <\/p>\n    <ul>\n        <li>\n            <strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u0930\u094d\u0917:<\/strong> \u092e\u0947\u0902 \u092a\u094d\u0930\u092d\u0941\u0924\u094d\u0935\u0936\u093e\u0932\u0940 <strong>12 kV \u0938\u0947 40.5 kV<\/strong> \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u0914\u0930 \u092d\u093e\u0930\u0940 \u0909\u0926\u094d\u092f\u094b\u0917 \u0915\u0947 \u0932\u093f\u090f \u0938\u0940\u092e\u093e\u0964.\n        <\/li>\n        <li>\n            <strong>\u092e\u0941\u0916\u094d\u092f \u092a\u094d\u0930\u094c\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u0940:<\/strong> \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 <strong>\u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f<\/strong> \u0924\u0947\u091c\u093c \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0930\u093f\u0915\u0935\u0930\u0940 \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u094d\u091a-\u0936\u0942\u0928\u094d\u092f \u0915\u0915\u094d\u0937 (&lt; 10\u207b\u2076 \u092c\u093e\u0930) \u092e\u0947\u0902\u0964.\n        <\/li>\n        <li>\n            <strong>\u092e\u0941\u0916\u094d\u092f \u0932\u093e\u092d:<\/strong> \u0936\u0942\u0928\u094d\u092f \u0939\u0930\u093f\u0924\u0917\u0943\u0939 \u0917\u0948\u0938 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928 (\u0915\u094b\u0908 SF6 \u0928\u0939\u0940\u0902), \u0909\u091a\u094d\u091a \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0925\u093e\u092f\u093f\u0924\u094d\u0935 (30,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915), \u0914\u0930 \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u092a\u0926\u091a\u093f\u0939\u094d\u0928\u0964.\n        <\/li>\n        <li>\n            <strong>\u092e\u0941\u0916\u094d\u092f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917:<\/strong> \u0907\u0902\u0921\u094b\u0930 \u092e\u0947\u091f\u0932-\u0915\u094d\u0932\u0948\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 (\u091c\u0948\u0938\u0947, <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\">VS1 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/a>) \u0914\u0930 \u092c\u093e\u0939\u0930\u0940 \u092a\u094b\u0932-\u092e\u093e\u0909\u0902\u091f\u0947\u0921 \u0930\u093f\u0915\u094d\u0932\u094b\u091c\u093c\u0930 (\u091c\u0948\u0938\u0947, <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/zw32-vacuum-circuit-breaker\/\">ZW32 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/a>).\n        <\/li>\n    <\/ul>\n    <p>\n        <em><strong>\u092a\u0922\u093c\u0928\u0947 \u0915\u093e \u0938\u092e\u092f:<\/strong> ~8 \u092e\u093f\u0928\u091f | <strong>\u0932\u0915\u094d\u0937\u093f\u0924 \u0926\u0930\u094d\u0936\u0915:<\/strong> \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0905\u092d\u093f\u092f\u0902\u0924\u093e, \u0908\u092a\u0940\u0938\u0940, \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0911\u092a\u0930\u0947\u091f\u0930<\/em>\n    <\/p>\n<\/div>\n\n\n\n<p><strong>\u092e\u093e\u0928\u0915 \u0938\u0902\u0926\u0930\u094d\u092d:<\/strong> <a href=\"https:\/\/webstore.iec.ch\/publication\/6734\" target=\"_blank\" rel=\"noopener\">\u0906\u0908\u0908\u0938\u0940 62271-100<\/a>, IEEE C37.04<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940) \u0915\u094d\u092f\u093e \u0939\u0948? \u0915\u093e\u0930\u094d\u092f \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0914\u0930 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0917\u093e\u0907\u0921\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/r4ByjQDZL40?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-introduction-why-vacuum-circuit-breakers-matter-in-modern-power-systems\">1. \u092a\u0930\u093f\u091a\u092f \u2013 \u0906\u0927\u0941\u0928\u093f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u093e \u092e\u0939\u0924\u094d\u0935<\/h2>\n\n\n\n<p>\u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c (MV) \u092c\u093f\u091c\u0932\u0940 \u0935\u093f\u0924\u0930\u0923 \u0915\u0947 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b \u0930\u0939\u0947 \u092a\u0930\u093f\u0926\u0943\u0936\u094d\u092f \u092e\u0947\u0902, \u201c\u092b\u093f\u091f-\u090f\u0902\u0921-\u092b\u0949\u0930\u0917\u0947\u091f\u201d \u0926\u0930\u094d\u0936\u0928 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0935\u0930\u094d\u0923 \u092e\u093e\u0928\u0915 \u092c\u0928 \u0917\u092f\u093e \u0939\u0948\u0964 \u091c\u0948\u0938\u0947-\u091c\u0948\u0938\u0947 \u092c\u093f\u091c\u0932\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901 \u0915\u0947\u0902\u0926\u094d\u0930\u0940\u0915\u0943\u0924 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0938\u0947 \u091c\u091f\u093f\u0932, \u0935\u093f\u0915\u0947\u0902\u0926\u094d\u0930\u0940\u0915\u0943\u0924 \u0917\u094d\u0930\u093f\u0921\u094d\u0938 \u092e\u0947\u0902 \u0930\u0942\u092a\u093e\u0902\u0924\u0930\u093f\u0924 \u0939\u094b \u0930\u0939\u0940 \u0939\u0948\u0902 \u091c\u094b \u0928\u0935\u0940\u0915\u0930\u0923\u0940\u092f \u090a\u0930\u094d\u091c\u093e \u0938\u094d\u0930\u094b\u0924\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u090f\u0915\u0940\u0915\u0943\u0924 \u0939\u0948\u0902, \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0930 \u092e\u093e\u0902\u0917\u0947\u0902 \u092c\u0926\u0932 \u0917\u0908 \u0939\u0948\u0902\u0964 \u0905\u092c \u0915\u0947\u0935\u0932 \u0926\u094b\u0937 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0928\u093e \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0928\u0939\u0940\u0902 \u0939\u0948; \u0906\u0927\u0941\u0928\u093f\u0915 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0902\u092d\u093e\u0932\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0915\u0920\u094b\u0930 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0914\u0930 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0935\u094d\u092f\u092f (OPEX) \u0915\u094b \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<p>\u0907\u0938 \u0938\u0902\u0926\u0930\u094d\u092d \u092e\u0947\u0902, <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\"><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/strong><\/a> (VCB) \u0928\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0924\u0915\u0928\u0940\u0915\u0940 \u0932\u0921\u093c\u093e\u0908 \u0928\u093f\u0930\u094d\u0923\u093e\u092f\u0915 \u0930\u0942\u092a \u0938\u0947 \u091c\u0940\u0924 \u0932\u0940 \u0939\u0948\u0964 <strong>12 kV \u0914\u0930 40.5 kV<\/strong>. \u0926\u0936\u0915\u094b\u0902 \u092a\u0939\u0932\u0947 \u092c\u0932\u094d\u0915 \u0911\u092f\u0932 \u0914\u0930 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0911\u092f\u0932 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u094b \u0935\u093f\u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926, VCBs \u0905\u092c \u0936\u094d\u0930\u0947\u0937\u094d\u0920 \u0924\u0915\u0928\u0940\u0915\u0940 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0914\u0930 \u0917\u094d\u0930\u0940\u0928\u0939\u093e\u0909\u0938 \u0917\u0948\u0938\u094b\u0902 \u0915\u0947 \u0916\u093f\u0932\u093e\u092b \u0915\u0921\u093c\u0947 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0928\u093f\u092f\u092e\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 SF\u2086 (\u0938\u0932\u094d\u092b\u0930 \u0939\u0947\u0915\u094d\u0938\u093e\u092b\u094d\u0932\u094b\u0930\u093e\u0907\u0921) \u0924\u0915\u0928\u0940\u0915 \u0915\u094b \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930 \u0930\u0939\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915\u0932 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902, \u092a\u094d\u0932\u093e\u0902\u091f \u092a\u094d\u0930\u092c\u0902\u0927\u0915\u094b\u0902 \u0914\u0930 \u0908\u092a\u0940\u0938\u0940 \u0920\u0947\u0915\u0947\u0926\u093e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u0940 \u0938\u0924\u0939\u0940 \u0938\u092e\u091d \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0928\u0939\u0940\u0902 \u0939\u0948\u0964 \u0909\u091a\u094d\u091a-\u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u093e\u0907\u0915\u093f\u0932 \u0935\u093e\u0932\u0940 \u0938\u094d\u091f\u0940\u0932 \u092e\u093f\u0932, \u090f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0921\u0947\u091f\u093e \u0938\u0947\u0902\u091f\u0930 \u092f\u093e \u0926\u0942\u0930\u0938\u094d\u0925 \u0916\u0928\u0928 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0938\u0939\u0940 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u092d\u094c\u0924\u093f\u0915\u0940, \u0924\u093e\u092a\u0940\u092f \u0935\u094d\u092f\u0935\u0939\u093e\u0930 \u0914\u0930 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u0940 \u0917\u0939\u0930\u0940 \u0938\u092e\u091d \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u092f\u0939 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u0928 \u0909\u0938 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917-\u0938\u094d\u0924\u0930\u0940\u092f \u0905\u0902\u0924\u0930\u094d\u0926\u0943\u0937\u094d\u091f\u093f \u0915\u094b \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-what-is-a-vacuum-circuit-breaker\">2. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094d\u092f\u093e \u0939\u0948?<\/h2>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u090f\u0915 \u092e\u0927\u094d\u092f\u092e \u092f\u093e \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0909\u092a\u0915\u0930\u0923 \u0939\u0948 \u091c\u0939\u093e\u0901 \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f\u2014\u0927\u093e\u0930\u093e \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u0928\u2014\u090f\u0915 \u0939\u0930\u094d\u092e\u0947\u091f\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u0940\u0932\u092c\u0902\u0926 \u0915\u0915\u094d\u0937 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0939\u094b\u0924\u093e \u0939\u0948 \u091c\u093f\u0938\u0947 \u090f\u0915 <strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 (VI)<\/strong>. \u201c\u0935\u0948\u0915\u094d\u092f\u0942\u092e\u201d \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 $10^{-4}$ Pa ($10^{-6}$ mbar) \u0938\u0947 \u0928\u0940\u091a\u0947 \u0915\u0947 \u0926\u092c\u093e\u0935 \u0938\u094d\u0924\u0930 \u0915\u094b \u0938\u0902\u0926\u0930\u094d\u092d\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u092a\u0930\u093f\u092a\u094d\u0930\u0947\u0915\u094d\u0937\u094d\u092f \u0938\u0947 VCB \u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935 \u092e\u0947\u0902 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e\u0947\u0902 \u0926\u0947\u0916\u0928\u093e \u0939\u094b\u0917\u093e \u0915\u093f <strong>\u0935\u0915\u094d\u0930 \u0915\u093e \u092d\u094c\u0924\u093f\u0915\u0940<\/strong>. \u0905\u0928\u094d\u092f \u0924\u0915\u0928\u0940\u0915\u094b\u0902 \u092e\u0947\u0902, \u0906\u0930\u094d\u0915 \u0906\u0938\u092a\u093e\u0938 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e (\u0924\u0947\u0932 \u0935\u093e\u0937\u094d\u092a, \u0935\u093e\u092f\u0941, \u092f\u093e SF\u2086) \u0938\u0947 \u0928\u093f\u0930\u094d\u092e\u093f\u0924 \u090f\u0915 \u0906\u092f\u0928\u093f\u0924 \u0917\u0948\u0938 (\u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e) \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092e\u0947\u0902, \u0906\u0938\u092a\u093e\u0938 \u0915\u094b\u0908 \u0917\u0948\u0938 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964 \u0906\u0930\u094d\u0915 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u090f\u0915 <strong>\u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e<\/strong>, \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0915\u0947 \u0915\u094d\u0937\u0923 \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0947 \u0938\u094d\u0935\u092f\u0902 \u0935\u093e\u0937\u094d\u092a\u0940\u0915\u0930\u0923 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"definition-by-technical-contrast\">\u0924\u0915\u0928\u0940\u0915\u0940 \u0935\u093f\u0930\u094b\u0927\u093e\u092d\u093e\u0938 \u0926\u094d\u0935\u093e\u0930\u093e \u092a\u0930\u093f\u092d\u093e\u0937\u093e<\/h3>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u094d\u092f\u093e \u0939\u0948, \u092f\u0939 \u0938\u092e\u091d\u0928\u093e <em>\u0939\u0948<\/em> \u092f\u0939 \u0938\u092e\u091d\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948 \u0915\u093f \u092f\u0939 \u0915\u094d\u092f\u093e \u0939\u0948\u0964 <em>\u0928\u0939\u0940\u0902 \u0939\u0948<\/em>. \u092a\u0930 \u0939\u092e\u093e\u0930\u0940 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0924\u0941\u0932\u0928\u093e \u0926\u0947\u0916\u0947\u0902 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor-vs-vacuum-circuit-breaker-medium-voltage-panel\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0928\u093e\u092e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/a> \u092a\u0948\u0928\u0932 \u091a\u092f\u0928 \u0915\u0940 \u092c\u093e\u0930\u0940\u0915\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0932\u0947\u0915\u093f\u0928 \u0938\u093e\u092e\u093e\u0928\u094d\u092f\u0924\u0903:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092c\u0928\u093e\u092e \u0924\u0947\u0932 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (OCBs):<\/strong> OCBs \u0906\u0930\u094d\u0915 \u0915\u0940 \u090a\u0930\u094d\u091c\u093e \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0924\u0947\u0932 \u0915\u094b \u0935\u093e\u0937\u094d\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u091c\u093f\u0938\u0938\u0947 \u0906\u0930\u094d\u0915 \u0915\u094b \u0920\u0902\u0921\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u091c\u0928 \u092c\u0941\u0932\u092c\u0941\u0932\u093e \u092c\u0928\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0927\u0940\u092e\u0940 \u0939\u0948, \u090f\u0915 \u092c\u0921\u093c\u0947 \u0906\u0917 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u091c\u0928\u094d\u092e \u0926\u0947\u0924\u0940 \u0939\u0948, \u0914\u0930 \u0915\u093e\u0930\u094d\u092c\u094b\u0928\u093e\u0907\u091c\u094d\u0921 \u0905\u0935\u0936\u0947\u0937 \u091b\u094b\u0921\u093c\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0924\u0947\u0932 \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 VCBs \u0907\u0928 \u091c\u094b\u0916\u093f\u092e\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n\n\n\n<li><strong>\u092c\u0928\u093e\u092e \u090f\u092f\u0930 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 (\u090f\u0938\u0940\u092c\u0940):<\/strong> ACBs \u0935\u093e\u092f\u0941\u092e\u0902\u0921\u0932\u0940\u092f \u0939\u0935\u093e \u092e\u0947\u0902 \u0906\u0930\u094d\u0915 \u0915\u094b \u092b\u0948\u0932\u093e\u0928\u0947 \u0914\u0930 \u0920\u0902\u0921\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0930\u094d\u0915 \u091a\u094d\u092f\u0942\u091f\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 12 kV \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u090f\u0915 ACB \u0915\u094b \u0935\u093f\u0936\u093e\u0932 \u0915\u094d\u0932\u093f\u092f\u0930\u0947\u0902\u0938 \u0926\u0942\u0930\u0940 \u0914\u0930 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092c\u094d\u0932\u094b-\u0906\u0909\u091f \u0915\u0949\u0907\u0932\u094d\u0938 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u094b \u0909\u0928\u094d\u0939\u0947\u0902 \u0906\u0927\u0941\u0928\u093f\u0915, \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f \u092d\u094c\u0924\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0905\u0928\u0941\u092a\u092f\u0941\u0915\u094d\u0924 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948\u0902\u0964.<\/li>\n\n\n\n<li><strong>\u090f\u0938\u090f\u092b\u2086 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0935\u093f\u0930\u0941\u0926\u094d\u0927:<\/strong> SF\u2086 \u090f\u0915 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u0928\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0917\u0948\u0938 \u0939\u0948 \u091c\u094b \u092e\u0941\u0915\u094d\u0924 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0915\u094b \u0917\u094d\u0930\u0939\u0923 \u0915\u0930\u0915\u0947 \u0906\u0930\u094d\u0915 \u0915\u094b \u092c\u0941\u091d\u093e\u0924\u0940 \u0939\u0948\u0964 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0939\u094b\u0928\u0947 \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926, SF\u2086 \u090f\u0915 \u0936\u0915\u094d\u0924\u093f\u0936\u093e\u0932\u0940 \u0917\u094d\u0930\u0940\u0928\u0939\u093e\u0909\u0938 \u0917\u0948\u0938 \u0939\u0948 (GWP \u0932\u0917\u092d\u0917 23,500)\u0964 \u0907\u0938\u0915\u0947 \u0905\u0932\u093e\u0935\u093e, SF\u2086 \u0915\u0947 \u0905\u092a\u0918\u091f\u0928 \u0909\u0924\u094d\u092a\u093e\u0926 (\u092a\u093e\u0909\u0921\u0930) \u0935\u093f\u0937\u0948\u0932\u0947 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u091c\u091f\u093f\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 VCB \u0938\u094d\u0935\u092d\u093e\u0935\u0924\u0903 \u201c\u0938\u094d\u0935\u091a\u094d\u091b\u201d \u0939\u094b\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0907\u0928\u092e\u0947\u0902 \u0917\u0948\u0938 \u0939\u0948\u0902\u0921\u0932\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart.webp\" alt=\"xbrele-\u0924\u0915\u0928\u0940\u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u091a\u093e\u0930\u094d\u091f \u091c\u094b SF6 \u0914\u0930 \u0924\u0947\u0932 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u0947 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0902\u092c\u0902\u0927\u0940 \u0932\u093e\u092d\u094b\u0902 \u0915\u094b \u0909\u091c\u093e\u0917\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.\" class=\"wp-image-2120\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u0932\u093e\u092d \u0909\u0920\u093e\u0924\u093e \u0939\u0948 <strong>\u0914\u0938\u0924 \u092e\u0941\u0915\u094d\u0924 \u092a\u0925<\/strong> \u0938\u093f\u0926\u094d\u0927\u093e\u0928\u094d\u0924: \u0909\u091a\u094d\u091a \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u092e\u0947\u0902 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928 \u0917\u0948\u0938 \u0905\u0923\u0941\u0913\u0902 \u0938\u0947 \u091f\u0915\u0930\u093e\u090f \u092c\u093f\u0928\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0948\u092a \u092a\u093e\u0930 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u091f\u0915\u0930\u093e\u0935 \u0915\u0947 \u0905\u092d\u093e\u0935 \u092e\u0947\u0902 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928 \u0939\u093f\u092e\u0938\u094d\u0916\u0932\u0928 (\u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928) \u0906\u0930\u0902\u092d \u0915\u0930\u0928\u093e \u0915\u0920\u093f\u0928 \u0939\u094b\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u0917\u0948\u092a\u094b\u0902 \u0915\u094b \u0915\u092e \u0926\u0942\u0930\u0940 \u092a\u0930 \u0935\u093e\u092f\u0941 \u092f\u093e SF\u2086 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-main-components-of-a-vacuum-circuit-breaker\">3. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u092e\u0941\u0916\u094d\u092f \u0918\u091f\u0915<\/h2>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947\u0935\u0932 \u090f\u0915 \u201c\u0938\u094d\u0935\u093f\u091a\u201d \u0928\u0939\u0940\u0902 \u0939\u0948; \u092f\u0939 \u090f\u0915 \u0938\u091f\u0940\u0915 \u0930\u0942\u092a \u0938\u0947 \u090f\u0915\u0940\u0915\u0943\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0939\u0948\u0964 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u0924\u0902\u0924\u094d\u0930 \u0915\u0947 \u092c\u0940\u091a \u0924\u093e\u0932\u092e\u0947\u0932 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vacuum-interrupter-the-bottle\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 (\u201c\u092c\u094b\u0924\u0932\u201d)<\/h3>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u0939\u0943\u0926\u092f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0939\u0948\u0964 \u0907\u0938\u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0905\u091f\u0942\u091f \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u0932\u0917\u094d\u0928:<\/strong> \u0909\u091a\u094d\u091a-\u0936\u094d\u0930\u0947\u0923\u0940 \u0915\u0940 \u090f\u0932\u0941\u092e\u093f\u0928\u093e \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u0938\u0947 \u0928\u093f\u0930\u094d\u092e\u093f\u0924, \u0927\u093e\u0924\u0941 \u0915\u0947 \u090f\u0902\u0921-\u0915\u0948\u092a\u094d\u0938 \u0938\u0947 \u092c\u094d\u0930\u0947\u091c\u093c \u0915\u093f\u092f\u093e \u0917\u092f\u093e\u0964 \u092f\u0939 20\u201330 \u0935\u0930\u094d\u0937\u094b\u0902 \u0924\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0917\u093e\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 (\u0906\u0932\u094b\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0927\u093e\u0924\u0941\u0936\u093e\u0938\u094d\u0924\u094d\u0930):<\/strong> \u0906\u092a \u0936\u0941\u0926\u094d\u0927 \u0924\u093e\u0902\u092c\u0947 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u0947; \u0935\u0947 \u090f\u0915 \u0938\u093e\u0925 \u0935\u0947\u0932\u094d\u0921 \u0939\u094b \u091c\u093e\u090f\u0902\u0917\u0947\u0964 \u0906\u0927\u0941\u0928\u093f\u0915 \u0935\u0940\u0938\u0940\u092c\u0940 \u090f\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <strong>\u0924\u093e\u0902\u092c\u093e-\u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e (CuCr)<\/strong> \u092e\u093f\u0936\u094d\u0930\u0927\u093e\u0924\u0941 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 75% Cu \/ 25% Cr)\u0964 \u0924\u093e\u0902\u092c\u093e \u091a\u093e\u0932\u0915\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f \u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u201c\u0917\u0947\u091f\u0930\u093f\u0902\u0917\u201d (\u092d\u091f\u0915\u0924\u0940 \u0917\u0948\u0938 \u0905\u0923\u0941\u0913\u0902 \u0915\u094b \u0905\u0935\u0936\u094b\u0937\u093f\u0924 \u0915\u0930\u0928\u093e) \u092e\u0947\u0902 \u0938\u0939\u093e\u092f\u0924\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u094d\u092f\u093e\u092e\u093f\u0924\u093f (\u090f\u090f\u092e\u090f\u092b \u092c\u0928\u093e\u092e \u0906\u0930\u090f\u092e\u090f\u092b):<\/strong> \u092f\u0939 \u090f\u0915 \u092a\u094d\u0930\u092e\u0941\u0916 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0935\u093f\u0935\u0930\u0923 \u0939\u0948\u0964.\n<ul class=\"wp-block-list\">\n<li><em>\u0906\u0930\u090f\u092e\u090f\u092b (\u0905\u0915\u094d\u0937\u0940\u092f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930):<\/em> \u0935\u0915\u094d\u0930 \u0915\u094b \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093f\u0928\u093e\u0930\u0947 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0918\u0942\u092e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092e\u091c\u092c\u0942\u0930 \u0915\u0930\u0928\u0947 \u0939\u0947\u0924\u0941 \u0938\u0930\u094d\u092a\u093f\u0932 \u0938\u094d\u0932\u0949\u091f\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u092a\u093f\u0918\u0932\u0928 \u0930\u094b\u0915\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><em>\u090f\u090f\u092e\u090f\u092b (\u0905\u0915\u094d\u0937\u0940\u092f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930):<\/em> \u090f\u0915 \u0915\u0949\u0907\u0932 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0927\u094d\u0930\u0941\u0935\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0906\u0930\u094d\u0915 \u0915\u0947 \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u092c\u0928\u093e\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0906\u0930\u094d\u0915 \u0915\u094b \u201c\u0935\u093f\u0915\u0940\u0930\u094d\u0923\u201d \u092e\u094b\u0921 \u092e\u0947\u0902 \u0930\u0916\u0924\u093e \u0939\u0948, \u091c\u094b \u092a\u0942\u0930\u0940 \u0938\u0924\u0939 \u092a\u0930 \u0938\u092e\u093e\u0928 \u0930\u0942\u092a \u0938\u0947 \u092b\u0948\u0932\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964. <strong>\u0909\u091a\u094d\u091a \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e\u0913\u0902 (\u091c\u0948\u0938\u0947, 40kA, 50kA) \u0915\u0947 \u0932\u093f\u090f AMF \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964<\/strong> \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092f\u0939 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0915\u094d\u0937\u0930\u0923 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964. <em>(\u092f\u0939 \u092d\u0940 \u0926\u0947\u0916\u0947\u0902: <\/em><a href=\"https:\/\/xbrele.com\/hi\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\"><em>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0906\u0930\u094d\u0915 \u0915\u094b \u0915\u0948\u0938\u0947 \u092c\u0941\u091d\u093e\u0924\u093e \u0939\u0948?<\/em><\/a><em> \u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0906\u0930\u094d\u0915 \u092d\u094c\u0924\u093f\u0915\u0940 \u0915\u0947 \u0932\u093f\u090f\u0964.<\/em><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view.webp\" alt=\"xbre\u0932\u0947-\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u094b\u0932 \u092f\u0942\u0928\u093f\u091f \u0915\u093e \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0935\u093f\u0938\u094d\u092b\u094b\u091f\u093f\u0924 \u0926\u0943\u0936\u094d\u092f \u0906\u0930\u0947\u0916, \u091c\u093f\u0938\u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930, CuCr \u0938\u0902\u092a\u0930\u094d\u0915, \u092c\u0947\u0932\u094b\u091c\u093c \u0914\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0930\u0949\u0921 \u0926\u093f\u0916\u093e\u090f \u0917\u090f \u0939\u0948\u0902\u0964.\" class=\"wp-image-2121\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-bellows\">\u092b\u0942\u0902\u0915\u0928\u0940<\/h3>\n\n\n\n<p>\u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0921\u093f\u091c\u093c\u093e\u0907\u0928\u094b\u0902 \u0915\u0940 \u0938\u092c\u0938\u0947 \u092c\u0921\u093c\u0940 \u0915\u092e\u091c\u094b\u0930\u0940, \u092c\u0947\u0932\u094b\u091c\u093c \u090f\u0915 \u0938\u094d\u091f\u0947\u0928\u0932\u0947\u0938 \u0938\u094d\u091f\u0940\u0932 \u0915\u0940 \u0905\u0915\u0949\u0930\u094d\u0921\u093f\u092f\u0928 \u091c\u0948\u0938\u0940 \u091f\u094d\u092f\u0942\u092c \u0939\u0948 \u091c\u094b \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094b \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 6 \u092e\u093f\u092e\u0940 \u0938\u0947 20 \u092e\u093f\u092e\u0940 \u0924\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948, \u092c\u093f\u0928\u093e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0940\u0932 \u0915\u094b \u0924\u094b\u0921\u093c\u0947\u0964 \u0906\u0927\u0941\u0928\u093f\u0915 \u0939\u093e\u0907\u0921\u094d\u0930\u094b-\u092b\u0949\u0930\u094d\u092e\u094d\u0921 \u092c\u0947\u0932\u094b\u091c\u093c \u0915\u094b \u0930\u0947\u091f \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 <strong>\u090f\u092e2 \u0935\u0930\u094d\u0917<\/strong> \u091f\u093f\u0915\u093e\u090a\u092a\u0928 (10,000 \u0938\u0947 30,000 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928), \u091c\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0938\u0947 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operating-mechanism\">\u0915\u093e\u0930\u094d\u092f\u092a\u094d\u0930\u0923\u093e\u0932\u0940<\/h3>\n\n\n\n<p>\u091a\u0942\u0902\u0915\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0915\u093e \u0938\u094d\u091f\u094d\u0930\u094b\u0915 (\u0926\u0942\u0930\u0940) SF\u2086 \u092f\u093e \u0924\u0947\u0932 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u092c\u0939\u0941\u0924 \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948, \u0907\u0938\u0932\u093f\u090f \u0907\u0938 \u0924\u0902\u0924\u094d\u0930 \u0915\u094b \u0938\u0902\u0915\u094d\u0937\u093f\u092a\u094d\u0924 \u0926\u0942\u0930\u0940 \u092e\u0947\u0902 \u0938\u091f\u0940\u0915 \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0915\u0947 \u0938\u093e\u0925 \u0909\u091a\u094d\u091a \u092c\u0932 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0935\u0938\u0902\u0924-\u0938\u0902\u0917\u094d\u0930\u0939\u0940\u0924 \u090a\u0930\u094d\u091c\u093e:<\/strong> \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u0964 \u090f\u0915 \u092e\u094b\u091f\u0930 \u090f\u0915 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u094b \u091a\u093e\u0930\u094d\u091c \u0915\u0930\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0947 \u0932\u0949\u091a \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u094b \u0930\u093f\u0932\u0940\u091c\u093c \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u092e\u091c\u092c\u0942\u0924 \u0914\u0930 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u090f\u0915\u094d\u091f\u094d\u092f\u0942\u090f\u091f\u0930:<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u092a\u0915\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0925\u093e\u092f\u0940 \u091a\u0941\u0902\u092c\u0915 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u094b\u0932\u0928\u0949\u0907\u0921 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u090f\u0915 \u0938\u0930\u0932\u0940\u0915\u0943\u0924 \u0921\u093f\u091c\u093c\u093e\u0907\u0928\u0964 \u0915\u092e \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925, \u092f\u0939 \u0909\u091a\u094d\u091a \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0936\u0915\u094d\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u091c\u091f\u093f\u0932 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"primary-conductors-insulation-system\">\u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u091a\u093e\u0932\u0915 \u090f\u0935\u0902 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u0940<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u090f\u092e\u094d\u092c\u0947\u0921\u0947\u0921 \u092a\u094b\u0932:<\/strong> \u091c\u0948\u0938\u0947 \u0909\u0928\u094d\u0928\u0924 VCBs \u092e\u0947\u0902 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\"><strong>VS1 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/strong><\/a>, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093f\u0928 \u092e\u0947\u0902 \u0922\u093e\u0932\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u201c\u090f\u092e\u094d\u092c\u0947\u0921\u0947\u0921 \u092a\u094b\u0932\u201d \u0924\u0915\u0928\u0940\u0915 \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u092c\u094b\u0924\u0932 \u0915\u094b \u0927\u0942\u0932, \u0928\u092e\u0940 \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091d\u091f\u0915\u0947 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0915\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0926\u0942\u0930\u0940 \u092e\u0947\u0902 \u0909\u0932\u094d\u0932\u0947\u0916\u0928\u0940\u092f \u0935\u0943\u0926\u094d\u0927\u093f \u0939\u094b\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0917\u0902\u0926\u0947 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0902 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0902\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-auxiliary-circuits\">\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u090f\u0935\u0902 \u0938\u0939\u093e\u092f\u0915 \u092a\u0930\u093f\u092a\u0925<\/h3>\n\n\n\n<p>\u0907\u0938\u092e\u0947\u0902 \u090f\u0902\u091f\u0940-\u092a\u0902\u092a\u093f\u0902\u0917 \u0930\u093f\u0932\u0947 (\u091c\u094b \u0928\u093f\u0930\u0902\u0924\u0930 \u0926\u094b\u0937 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0916\u0941\u0932\u0928\u0947-\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948), \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932\u094d\u0938, \u0914\u0930 SCADA \u092b\u0940\u0921\u092c\u0948\u0915 \u0915\u0947 \u0932\u093f\u090f \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-how-does-a-vacuum-circuit-breaker-work\">4. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0948\u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948?<\/h2>\n\n\n\n<p>\u092f\u0939 \u0911\u092a\u0930\u0947\u0936\u0928 \u0938\u092e\u092f \u0915\u0947 \u0916\u093f\u0932\u093e\u092b \u090f\u0915 \u0926\u094c\u0921\u093c \u0939\u0948\u2014\u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947, \u0915\u0947 \u092c\u0940\u091a \u090f\u0915 \u0926\u094c\u0921\u093c <strong>\u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0935\u094b\u0932\u094d\u091f\u0947\u091c (\u091f\u0940\u0906\u0930\u0935\u0940)<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0914\u0930 \u0915\u0947 \u092a\u093e\u0930 \u0909\u092d\u0930 \u0930\u0939\u093e <strong>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0917\u0948\u092a \u0915\u093e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"normal-closed-condition\">\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092c\u0902\u0926 \u0938\u094d\u0925\u093f\u0924\u093f<\/h3>\n\n\n\n<p>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0927\u093e\u0930\u093e \u0938\u094d\u0925\u093f\u0930 \u0914\u0930 \u091a\u0932 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0938\u0947 \u0939\u094b\u0915\u0930 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0905\u0924\u094d\u092f\u0902\u0924 \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948 (\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u092e, \u03bc\u03a9 \u092e\u0947\u0902 \u092e\u093e\u092a\u093e \u091c\u093e\u0924\u093e \u0939\u0948)\u0964 \u092c\u093e\u0939\u0930\u0940 \u0924\u0902\u0924\u094d\u0930 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u0921\u093e\u092f\u0928\u093e\u092e\u093f\u0915 \u092c\u0932\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0916\u0941\u0932\u0928\u0947 \u0938\u0947 \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0926\u092c\u093e\u0935 (\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0932) \u0932\u093e\u0917\u0942 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"fault-detection-and-trip-command\">\u0926\u094b\u0937 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e \u0914\u0930 \u091f\u094d\u0930\u093f\u092a \u0915\u092e\u093e\u0902\u0921<\/h3>\n\n\n\n<p>\u0938\u0902\u0930\u0915\u094d\u0937\u0923 \u0930\u093f\u0932\u0947 \u0938\u0947 \u0938\u0902\u0915\u0947\u0924 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0939\u094b\u0924\u0947 \u0939\u0940 \u0932\u0948\u091a \u092e\u0941\u0915\u094d\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u091a\u0932\u0924\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094b \u0928\u0940\u091a\u0947 \u0915\u0940 \u0913\u0930 \u0916\u0940\u0902\u091a\u0924\u0940 \u0939\u0948\u0902\u0964 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0915\u0940 \u0917\u0924\u093f \u0905\u0924\u094d\u092f\u0902\u0924 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u2014\u092c\u0939\u0941\u0924 \u0927\u0940\u092e\u0940 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0906\u0930\u094d\u0915 \u092c\u0939\u0941\u0924 \u0926\u0947\u0930 \u0924\u0915 \u091c\u0932\u0924\u093e \u0930\u0939\u0924\u093e \u0939\u0948; \u092c\u0939\u0941\u0924 \u0924\u0947\u091c \u0939\u094b\u0928\u0947 \u092a\u0930 \u092c\u0947\u0932\u094b\u091c\u093c \u092b\u091f \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"arc-extinction-the-current-zero-phenomenon\">\u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f: \u201c\u0915\u0930\u0902\u091f \u091c\u0940\u0930\u094b\u201d \u0918\u091f\u0928\u093e<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0909\u0924\u094d\u092a\u093e\u0926\u0928:<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0905\u0932\u0917 \u0939\u094b\u0924\u0947 \u0939\u0940, \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093e \u0905\u0902\u0924\u093f\u092e \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u092c\u093f\u0902\u0926\u0941 \u092a\u093f\u0918\u0932\u0915\u0930 \u092b\u091f \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e \u0915\u093e \u090f\u0915 \u092a\u0941\u0932 \u092c\u0928\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0938\u093e\u0930\u0923 \u092e\u094b\u0921:<\/strong> \u090f\u0915 \u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u090f \u0917\u090f AMF \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092e\u0947\u0902, \u092f\u0939 \u0906\u0930\u094d\u0915 \u092a\u0942\u0930\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u092a\u0930 \u092b\u0948\u0932 \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092c\u0921\u093c\u0947 \u092a\u0948\u092e\u093e\u0928\u0947 \u092a\u0930 \u092a\u093f\u0918\u0932\u0928\u0947 \u0938\u0947 \u092c\u091a\u093e\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0936\u0942\u0928\u094d\u092f:<\/strong> AC \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902, \u0927\u093e\u0930\u093e \u0938\u094d\u0935\u093e\u092d\u093e\u0935\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u0924\u093f \u0938\u0947\u0915\u0902\u0921 100 \u092c\u093e\u0930 \u0936\u0942\u0928\u094d\u092f \u0938\u0947 \u0939\u094b\u0915\u0930 \u0917\u0941\u091c\u0930\u0924\u0940 \u0939\u0948 (50 \u0939\u0930\u094d\u091f\u094d\u091c\u093c)\u0964 \u091c\u092c \u0927\u093e\u0930\u093e \u0936\u0942\u0928\u094d\u092f \u0915\u0947 \u0915\u0930\u0940\u092c \u092a\u0939\u0941\u0901\u091a\u0924\u0940 \u0939\u0948, \u0924\u094b \u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e \u092e\u0947\u0902 \u090a\u0930\u094d\u091c\u093e \u0915\u093e \u092a\u094d\u0930\u0935\u093e\u0939 \u0930\u0941\u0915 \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0926\u094d\u0930\u0941\u0924 \u0938\u0902\u0918\u0928\u0928:<\/strong> \u0915\u0930\u0902\u091f \u0936\u0942\u0928\u094d\u092f \u0939\u094b\u0928\u0947 \u0915\u0947 \u0920\u0940\u0915 \u0915\u094d\u0937\u0923 \u092a\u0930 \u0906\u0930\u094d\u0915 \u092c\u0941\u091d \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0927\u093e\u0924\u0941 \u0915\u093e \u0935\u093e\u0937\u094d\u092a \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0938\u0947\u0915\u0902\u0921\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0922\u093e\u0932\u094b\u0902 \u092a\u0930 \u0938\u0902\u0918\u0928\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f:<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0917\u0948\u092a \u0905\u092a\u0928\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0932\u0917\u092d\u0917 \u0924\u0941\u0930\u0902\u0924 \u0939\u0940 \u092a\u0941\u0928\u0903 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930 \u0932\u0947\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u092f\u0939 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0917\u094d\u0930\u093f\u0921 \u0938\u0947 \u092c\u0922\u093c\u0924\u0947 TRV \u0938\u0947 \u0924\u0947\u091c\u093c \u0939\u094b\u0924\u0940 \u0939\u0948, \u0924\u094b \u0935\u093f\u0930\u093e\u092e \u0938\u092b\u0932 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u0928\u0939\u0940\u0902, \u0924\u094b \u090f\u0915 <strong>\u092a\u0941\u0928\u0903 \u092a\u094d\u0930\u0939\u093e\u0930<\/strong> \u0918\u091f\u0924\u093e \u0939\u0948\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0905\u0924\u094d\u092f\u0902\u0924 \u0924\u0940\u0935\u094d\u0930 \u0930\u093f\u0915\u0935\u0930\u0940 \u0935\u0915\u094d\u0930\u0924\u093e \u0939\u0940 \u0907\u0938\u0947 \u0907\u0924\u0928\u093e \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948\u0964 \u0906\u0930\u094d\u0915 \u092d\u094c\u0924\u093f\u0915\u0940 \u092e\u0947\u0902 \u0917\u0939\u0930\u0940 \u0917\u094b\u0924\u093e\u0916\u094b\u0930\u0940 \u0915\u0947 \u0932\u093f\u090f, \u0938\u0902\u0926\u0930\u094d\u092d\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0941\u090f <a href=\"https:\/\/en.wikipedia.org\/wiki\/Paschen%27s_law\" target=\"_blank\" rel=\"noopener\">\u092a\u093e\u0936\u0947\u0928 \u0915\u093e \u0928\u093f\u092f\u092e<\/a> \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u0938\u092e\u091d\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092f\u0939 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram.webp\" alt=\"xbrele-\u0935\u0948\u0915\u094d\u092f\u0942\u092e-\u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930-\u0906\u0930\u094d\u0915-\u0928\u093f\u0930\u094b\u0927-\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e-\u0906\u0930\u0947\u0916\" class=\"wp-image-2122\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-vacuum-circuit-breaker-internal-structure-exploded-view\">5. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e (\u0935\u093f\u0916\u0902\u0921\u093f\u0924 \u0926\u0943\u0936\u094d\u092f)<\/h2>\n\n\n\n<p><em>(\u0928\u094b\u091f: \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0918\u091f\u0915 \u0935\u093f\u0928\u094d\u092f\u093e\u0938 \u0915\u0947 \u0932\u093f\u090f \u0915\u0943\u092a\u092f\u093e \u0905\u0928\u0941\u092d\u093e\u0917 3 \u092e\u0947\u0902 \u0926\u093f\u090f \u0917\u090f \u0906\u0930\u0947\u0916 \u0915\u094b \u0926\u0947\u0916\u0947\u0902\u0964 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u094b \u0938\u092e\u091d\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0938\u094d\u092b\u094b\u091f\u093f\u0924 \u0926\u0943\u0936\u094d\u092f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0964).<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-vacuum-circuit-breaker-vs-other-technologies\">6. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0928\u093e\u092e \u0905\u0928\u094d\u092f \u092a\u094d\u0930\u094c\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u093f\u092f\u093e\u0901<\/h2>\n\n\n\n<p>\u0928\u0940\u091a\u0947 \u0926\u093f\u092f\u093e \u0917\u092f\u093e \u0924\u0941\u0932\u0928\u093e \u091a\u093e\u0930\u094d\u091f \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948 \u0915\u093f VCB \u0915\u094b MV \u0915\u0947 \u0932\u093f\u090f \u0915\u094d\u092f\u094b\u0902 \u091a\u0941\u0928\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f SF\u2086 \u0915\u094b HV\/EHV \u0915\u0947 \u0932\u093f\u090f \u0906\u0930\u0915\u094d\u0937\u093f\u0924 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u0935\u093f\u0936\u0947\u0937\u0924\u093e<\/th><th>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/th><th>\u090f\u0938\u090f\u092b\u2086 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/th><th>\u0935\u093e\u092f\u0941 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u090f\u0938\u0940\u092c\u0940)<\/th><\/tr><tr><td><strong>\u0906\u0930\u094d\u0915 \u0936\u092e\u0928 \u092e\u093e\u0927\u094d\u092f\u092e<\/strong><\/td><td>\u0936\u0942\u0928\u094d\u092f ($&lt;10^{-6}$ \u092c\u093e\u0930)<\/td><td>\u0938\u0932\u094d\u092b\u0930 \u0939\u0947\u0915\u094d\u0938\u093e\u092b\u094d\u0932\u094b\u0930\u093e\u0907\u0921 \u0917\u0948\u0938<\/td><td>\u0935\u093e\u0924\u093e\u0935\u0930\u0923\u0940\u092f \u0935\u093e\u092f\u0941<\/td><\/tr><tr><td><strong>\u0915\u093e\u0930\u094d\u092f\u0935\u093e\u0939\u093f\u092f\u094b\u0902 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e<\/strong><\/td><td>\u0909\u091a\u094d\u091a (10,000 \u2013 30,000)<\/td><td>\u092e\u0927\u094d\u092f\u092e (2,000 \u2013 5,000)<\/td><td>\u0915\u092e<\/td><\/tr><tr><td><strong>\u0930\u0916\u0930\u0916\u093e\u0935<\/strong><\/td><td>\u091c\u0940\u0935\u0928 \u092d\u0930 \u0915\u0947 \u0932\u093f\u090f \u0938\u0940\u0932<\/td><td>\u0917\u0948\u0938 \u0926\u092c\u093e\u0935 \u091c\u093e\u0901\u091a \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948<\/td><td>\u0906\u0930\u094d\u0915 \u0936\u0942\u091f \u0938\u092b\u093e\u0908<\/td><\/tr><tr><td><strong>\u0906\u0915\u093e\u0930 \/ \u092a\u0926\u091a\u093f\u0939\u094d\u0928<\/strong><\/td><td>\u092c\u0939\u0941\u0924 \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f<\/td><td>\u0938\u0902\u0915\u094d\u0937\u093f\u092a\u094d\u0924<\/td><td>\u092c\u0921\u093c\u093e \/ \u092d\u093e\u0930\u0940<\/td><\/tr><tr><td><strong>\u0906\u0917 \u0915\u093e \u0916\u0924\u0930\u093e<\/strong><\/td><td>\u0915\u094b\u0908 \u0928\u0939\u0940\u0902<\/td><td>\u0928\u093f\u092e\u094d\u0928 (\u0905\u091c\u094d\u0935\u0932\u0928\u0936\u0940\u0932 \u0917\u0948\u0938)<\/td><td>\u092e\u0927\u094d\u092f\u092e (\u0906\u092f\u0928\u0940\u0915\u0943\u0924 \u0939\u0935\u093e)<\/td><\/tr><tr><td><strong>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f<\/strong><\/td><td><strong>\u0939\u0930\u093f\u0924<\/strong> (\u0936\u0942\u0928\u094d\u092f \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928)<\/td><td><strong>\u0909\u091a\u094d\u091a \u092a\u094d\u0930\u092d\u093e\u0935<\/strong> (\u091c\u0940\u090f\u091a\u091c\u0940)<\/td><td>\u0924\u091f\u0938\u094d\u0925<\/td><\/tr><tr><td><strong>\u0930\u093f\u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915 \u0930\u093f\u0938\u094d\u0915<\/strong><\/td><td>\u092c\u0939\u0941\u0924 \u0915\u092e (\u0909\u091a\u094d\u091a \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0917\u0924\u093f)<\/td><td>\u0915\u092e<\/td><td>\u092e\u0927\u094d\u092f\u092e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-typical-applications-of-vacuum-circuit-breakers\">7. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"substations-utilities\">\u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928 \u0914\u0930 \u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e\u0913\u0902<\/h3>\n\n\n\n<p>\u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e\u090f\u0901 \u0935\u093f\u0924\u0930\u0923 \u092b\u0940\u0921\u0930\u094b\u0902 (11kV \u0938\u0947 33kV) \u0915\u0947 \u0932\u093f\u090f VCBs \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964 \u0909\u091a\u094d\u091a \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0907\u0928\u094d\u0939\u0947\u0902 \u0926\u0942\u0930\u0938\u094d\u0925, \u092c\u093f\u0928\u093e \u092e\u093e\u0928\u0935 \u0938\u0902\u091a\u093e\u0932\u0928 \u0935\u093e\u0932\u0947 \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"industrial-plants-motor-switching\">\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0938\u0902\u092f\u0902\u0924\u094d\u0930 (\u092e\u094b\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917)<\/h3>\n\n\n\n<p>\u092f\u0939 \u090f\u0915 VCB \u0915\u093e \u0917\u0922\u093c \u0939\u0948\u0964 \u092e\u094b\u091f\u0930\u094d\u0938 \u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u091a\u093e\u0932\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 VCB \u092c\u093f\u0928\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0939\u091c\u093e\u0930\u094b\u0902 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u091a\u0915\u094d\u0930 \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>\u0905\u092d\u093f\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940 \u0928\u094b\u091f:<\/em> \u092e\u094b\u091f\u0930 \u092c\u0926\u0932\u0924\u0947 \u0938\u092e\u092f, \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u094b \u0938\u093e\u0935\u0927\u093e\u0928 \u0930\u0939\u0928\u093e \u091a\u093e\u0939\u093f\u090f <strong>\u0906\u092d\u093e\u0938\u0940 \u0915\u091f\u093e\u0908<\/strong> \u0914\u0930 \u0915\u0908 \u092c\u093e\u0930 \u092a\u0941\u0928\u0903 \u092a\u094d\u0930\u091c\u094d\u0935\u0932\u0928\u0964 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u093e \u090f\u0915 \u092e\u093e\u0928\u0915 \u092a\u094d\u0930\u0925\u093e \u0939\u0948\u0964 <strong>\u0906\u0930\u0938\u0940 \u0938\u094d\u0928\u092c\u0930\u094d\u0938<\/strong> \u092f\u093e \u092e\u094b\u091f\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f VCB \u0915\u0947 \u0938\u093e\u0925 \u091c\u093f\u0902\u0915 \u0911\u0915\u094d\u0938\u093e\u0907\u0921 \u0938\u0930\u094d\u091c \u0905\u0930\u0947\u0938\u094d\u091f\u0930\u094d\u0938\u0964.<\/li>\n\n\n\n<li><a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\"><strong>VS1 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/strong><\/a>: \u0907\u0928\u0921\u094b\u0930 \u092e\u0947\u091f\u0932-\u0915\u094d\u0932\u0948\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0948\u0928\u0932\u094b\u0902 (\u091c\u0948\u0938\u0947 KYN28 \u092a\u094d\u0930\u0915\u093e\u0930) \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f\u0915\u0930\u094d\u0924\u093e\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mining-arc-furnaces\">\u0916\u0928\u0928 \u090f\u0935\u0902 \u0906\u0930\u094d\u0915 \u092d\u091f\u094d\u091f\u093f\u092f\u093e\u0901<\/h3>\n\n\n\n<p>\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0906\u0930\u094d\u0915 \u092b\u0930\u094d\u0928\u0947\u0938 (EAF) \u090f\u0915 \u092a\u0930\u092e \u092f\u093e\u0924\u0928\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0939\u0948\u0902, \u091c\u093f\u0928\u092e\u0947\u0902 100 \u0924\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 <em>\u092a\u094d\u0930\u0924\u093f \u0926\u093f\u0928<\/em>. \u0915\u0947\u0935\u0932 \u0935\u0940\u0938\u0940\u092c\u0940 (\u0905\u0915\u094d\u0938\u0930 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u090f\u0915\u094d\u091f\u094d\u092f\u0942\u090f\u091f\u0930\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925) \u0939\u0940 \u0907\u0938 \u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u093e\u0907\u0915\u093f\u0932 \u092e\u0947\u0902 \u091f\u093f\u0915 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u0930\u094d\u092e\u0947\u091f\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u0940\u0932\u092c\u0902\u0926 \u0938\u0902\u092a\u0930\u094d\u0915 \u0916\u0926\u093e\u0928\u094b\u0902 \u092e\u0947\u0902 \u0905\u0915\u094d\u0938\u0930 \u092a\u093e\u090f \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u091a\u093e\u0932\u0915\u0936\u0940\u0932 \u0915\u094b\u092f\u0932\u093e \u0927\u0942\u0932 \u0914\u0930 \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e \u0938\u0947 \u092d\u0940 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0940 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"rmu-and-ring-networks\">\u0906\u0930\u090f\u092e\u092f\u0942 \u0914\u0930 \u0930\u093f\u0902\u0917 \u0928\u0947\u091f\u0935\u0930\u094d\u0915\u094d\u0938<\/h3>\n\n\n\n<p>\u0938\u094d\u092e\u093e\u0930\u094d\u091f \u0917\u094d\u0930\u093f\u0921\u094d\u0938 \u0915\u094b \u0935\u093f\u0924\u0930\u0923 \u0938\u094d\u0924\u0930 \u092a\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/zw32-vacuum-circuit-breaker\/\"><strong>ZW32 \u0906\u0909\u091f\u0921\u094b\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/strong><\/a>\u0905\u0915\u094d\u0938\u0930 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0926\u094b\u0937\u094b\u0902 (\u091c\u0948\u0938\u0947 \u092c\u093f\u091c\u0932\u0940 \u0917\u093f\u0930\u0928\u0947) \u0915\u094b \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0926\u0942\u0930 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0913\u0935\u0930\u0939\u0947\u0921 \u0932\u093e\u0907\u0928\u094b\u0902 \u092a\u0930 \u201c\u0911\u091f\u094b-\u0930\u093f\u0915\u094d\u0932\u094b\u091c\u093c\u0930\u201d \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0924\u0948\u0928\u093e\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/zw20-vacuum-circuit-breaker\/\"><strong>ZW20 \u092a\u094b\u0932-\u092e\u093e\u0909\u0902\u091f\u0947\u0921 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/strong><\/a>\u090f\u0915 \u092c\u093e\u0909\u0902\u0921\u094d\u0930\u0940 \u0938\u094d\u0935\u093f\u091a, \u091c\u094b \u0905\u0915\u094d\u0938\u0930 \u091f\u0948\u0902\u0915 \u0915\u0947 \u0932\u093f\u090f \u0917\u0948\u0938-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u092f\u093e \u0938\u0949\u0932\u093f\u0921-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0939\u094b\u0924\u093e \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092a\u094b\u0932 \u091f\u0949\u092a \u092a\u0930 \u0936\u0942\u0928\u094d\u092f \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-1024x559.webp\" alt=\"\u0935\u093f\u0924\u0930\u0923 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0915\u0902\u0915\u094d\u0930\u0940\u091f \u0915\u0947 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u092a\u094b\u0932 \u092a\u0930 \u0906\u0909\u091f\u0921\u094b\u0930 ZW32 \u092a\u094b\u0932-\u092e\u093e\u0909\u0902\u091f\u0947\u0921 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0938\u094d\u0925\u093e\u092a\u0928\u093e\u0964.\" class=\"wp-image-2123\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-1024x559.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-1536x838.webp 1536w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-2048x1117.webp 2048w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"8-faqs-engineering-maintenance-insights\">8. \u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928: \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0902\u092c\u0902\u0927\u0940 \u091c\u093e\u0928\u0915\u093e\u0930\u0940<\/h2>\n\n\n\n<p><strong>1. \u201c\u0915\u0930\u0902\u091f \u091a\u0949\u092a\u093f\u0902\u0917\u201d \u0918\u091f\u0928\u093e \u0915\u094d\u092f\u093e \u0939\u0948?<\/strong> \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u090f\u0915 \u092c\u0939\u0941\u0924 \u0939\u0940 \u0915\u0941\u0936\u0932 \u0905\u0935\u0930\u094b\u0927\u0915 \u0939\u0948, \u092f\u0939 \u0915\u092d\u0940-\u0915\u092d\u0940 \u0906\u0930\u094d\u0915 \u0915\u094b \u092c\u0941\u091d\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964 <em>\u092a\u0939\u0932\u0947<\/em> \u092a\u094d\u0930\u093e\u0915\u0943\u0924\u093f\u0915 \u0927\u093e\u0930\u093e \u0936\u0942\u0928\u094d\u092f (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, 0A \u0915\u0947 \u092c\u091c\u093e\u092f 3A \u092f\u093e 4A \u092a\u0930), \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u091b\u094b\u091f\u0947 \u092a\u094d\u0930\u0947\u0930\u0915 \u0927\u093e\u0930\u093e\u0913\u0902 (\u091c\u0948\u0938\u0947 \u092c\u093f\u0928\u093e \u0932\u094b\u0921 \u0935\u093e\u0932\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930) \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0938\u092e\u092f\u0964 \u092f\u0939 \u0905\u091a\u093e\u0928\u0915 \u201c\u091a\u0949\u092a\u201d \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u090a\u0930\u094d\u091c\u093e \u0915\u094b \u092b\u0901\u0938\u093e \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0909\u091a\u094d\u091a \u0915\u094d\u0937\u0923\u093f\u0915 \u0905\u0927\u093f-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f \u0906\u0927\u0941\u0928\u093f\u0915 CuCr \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0907\u0938\u0947 \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948, \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u092d\u093e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u091c \u0905\u0930\u0947\u0938\u094d\u091f\u0930 \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936 \u0915\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>2. \u092e\u0948\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0948\u0938\u0947 \u0915\u0930\u0942\u0901?<\/strong> \u0906\u092a \u0926\u0943\u0936\u094d\u092f \u0930\u0942\u092a \u0938\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u091c\u093e\u0901\u091a \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u0947\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>VIDAR \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e):<\/strong> \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u0909\u091a\u094d\u091a \u0921\u0940\u0938\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, 12kV \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0932\u093f\u090f 40kV \u0921\u0940\u0938\u0940) \u0932\u0917\u093e\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u093f\u0924 \u0939\u0948, \u0924\u094b \u0915\u094b\u0908 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964 \u092f\u0926\u093f \u0939\u0935\u093e \u0930\u093f\u0938\u093e\u0935 \u0915\u0930 \u0905\u0902\u0926\u0930 \u0906 \u0917\u0908 \u0939\u0948, \u0924\u094b \u092f\u0939 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0915\u0930 \u0926\u0947\u0917\u093e\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u0921\u0915\u094d\u091f\u094b\u0930) \u092a\u0930\u0940\u0915\u094d\u0937\u0923:<\/strong> \u092e\u0941\u0916\u094d\u092f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u092e\u093e\u092a\u0924\u093e \u0939\u0948 (\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u092e \u092e\u0947\u0902)\u0964 \u0909\u091a\u094d\u091a \u0930\u0940\u0921\u093f\u0902\u0917 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u093e\u0935 \u092f\u093e \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<p><strong>3. VCBs \u092e\u0947\u0902 \u201c\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917\u201d \u092e\u094b\u091f\u0930 \u0915\u094d\u092f\u094b\u0902 \u0939\u094b\u0924\u093e \u0939\u0948?<\/strong> \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u094b \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u092c\u0932 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u090f\u0915 \u091b\u094b\u091f\u093e \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u094b\u091f\u0930 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0947 \u092c\u093e\u0926 \u0907\u0938 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u094b \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u091a\u093e\u0930\u094d\u091c \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092c\u094d\u0930\u0947\u0915\u0930 \u0926\u094b\u0937 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0924\u0941\u0930\u0902\u0924 \u201c\u0913\u092a\u0928-\u0915\u094d\u0932\u094b\u091c-\u0913\u092a\u0928\u201d (O-C-O) \u091a\u0915\u094d\u0930 \u091a\u0932\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u092e\u0947\u0936\u093e \u0924\u0948\u092f\u093e\u0930 \u0930\u0939\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>4. \u0915\u094d\u092f\u093e \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0921\u0940\u0938\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948?<\/strong> \u0906\u092e \u0924\u094c\u0930 \u092a\u0930 \u0928\u0939\u0940\u0902\u0964 VCBs \u0906\u0930\u094d\u0915 \u0915\u094b \u092c\u0941\u091d\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f AC \u0927\u093e\u0930\u093e \u0915\u0947 \u0936\u0942\u0928\u094d\u092f \u0939\u094b\u0928\u0947 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 DC \u092a\u0930\u093f\u092a\u0925 \u092e\u0947\u0902 \u0927\u093e\u0930\u093e \u0938\u094d\u0935\u093e\u092d\u093e\u0935\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0915\u092d\u0940 \u0936\u0942\u0928\u094d\u092f \u0915\u094b \u092a\u093e\u0930 \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u0940\u0964 DC \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0924\u0915\u0928\u0940\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0939\u0947\u0924\u0941 \u0935\u093f\u0936\u0947\u0937 \u201c\u0915\u093e\u0909\u0902\u091f\u0930-\u0915\u0930\u0902\u091f \u0907\u0902\u091c\u0947\u0915\u094d\u0936\u0928\u201d \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>5. \u0905\u0917\u0930 \u092c\u0947\u0932\u094b\u091c\u093c \u0916\u0930\u093e\u092c \u0939\u094b \u091c\u093e\u090f\u0901 \u0924\u094b \u0915\u094d\u092f\u093e \u0939\u094b\u0917\u093e?<\/strong> \u092f\u0926\u093f \u092c\u0947\u0932\u094b\u091c\u093c \u092e\u0947\u0902 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0926\u0930\u093e\u0930 \u0906 \u091c\u093e\u090f, \u0924\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0916\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0926\u094b\u0937 \u0915\u094b \u0938\u093e\u092b \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0935\u093f\u092b\u0932 \u0930\u0939\u0947\u0917\u093e, \u091c\u093f\u0938\u0938\u0947 \u0905\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0906\u0930\u094d\u0915 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092a\u094b\u0932 \u092f\u0942\u0928\u093f\u091f \u0915\u093e \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u0938\u094d\u092b\u094b\u091f \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0907\u0938\u0940\u0932\u093f\u090f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0925\u093e\u092f\u093f\u0924\u094d\u0935 (M2 \u0936\u094d\u0930\u0947\u0923\u0940) \u090f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>6. \u0915\u094d\u092f\u093e \u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u0948\u0902?<\/strong> \u0939\u093e\u0901, \u0909\u091a\u094d\u091a \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092f\u0947 \u0907\u0938 \u0915\u093e\u0930\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0939\u0948\u0902 (\u0915\u094d\u0932\u093e\u0938 C2 \u0930\u0947\u091f\u093f\u0902\u0917)\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f, \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u092d\u0940-\u0915\u092d\u0940 \u0938\u091f\u0940\u0915 \u092a\u0949\u0907\u0902\u091f-\u0911\u0928-\u0935\u0947\u0935 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u092f\u093e \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"9-conclusion-cta\">9. \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937 + \u0938\u0940\u091f\u0940\u090f<\/h2>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u090f\u0915 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0924\u0915\u0928\u0940\u0915 \u0938\u0947 \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b\u0915\u0930 \u0906\u0927\u0941\u0928\u093f\u0915 \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0935\u0938\u0902\u0930\u091a\u0928\u093e \u0915\u0940 \u0930\u0940\u0922\u093c \u092c\u0928 \u0917\u092f\u093e \u0939\u0948\u0964 \u0907\u0938\u0915\u093e \u092a\u094d\u0930\u092d\u0941\u0924\u094d\u0935 \u0938\u0902\u092f\u094b\u0917\u0935\u0936 \u0928\u0939\u0940\u0902 \u0939\u0948\u2014\u092f\u0939 \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0939\u093f\u0924 \u092d\u094c\u0924\u093f\u0915 \u0932\u093e\u092d\u094b\u0902 \u0915\u093e \u092a\u0930\u093f\u0923\u093e\u092e \u0939\u0948: \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0906\u0930\u094d\u0915 \u091c\u094b \u0927\u093e\u0930\u093e \u0936\u0942\u0928\u094d\u092f \u092a\u0930 \u092c\u0941\u091d \u091c\u093e\u0924\u093e \u0939\u0948, \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0917\u0924\u093f \u091c\u094b \u0917\u094d\u0930\u093f\u0921 \u0915\u0947 \u0915\u094d\u0937\u0923\u093f\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0938\u0947 \u092d\u0940 \u0924\u0947\u091c \u0939\u0948, \u0914\u0930 \u090f\u0915 \u0938\u0940\u0932\u092c\u0902\u0926 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u091c\u094b \u0917\u0902\u0926\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0915\u094b \u0905\u0928\u0926\u0947\u0916\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0939\u093e\u0932\u093e\u0901\u0915\u093f \u0938\u092d\u0940 VCBs \u0938\u092e\u093e\u0928 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0947\u0964 \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e, CuCr \u092e\u093f\u0936\u094d\u0930 \u0927\u093e\u0924\u0941 \u0915\u0940 \u0936\u0941\u0926\u094d\u0927\u0924\u093e \u0914\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u0938\u091f\u0940\u0915\u0924\u093e \u092f\u0939 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 5 \u0938\u093e\u0932 \u091a\u0932\u0947\u0917\u093e \u092f\u093e 30 \u0938\u093e\u0932\u0964.<\/p>\n\n\n\n<p><strong>\u0917\u094d\u0930\u093f\u0921 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0947 \u0938\u092e\u091d\u094c\u0924\u093e \u0928 \u0915\u0930\u0947\u0902\u0964.<\/strong> \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092c\u0941\u0928\u093f\u092f\u093e\u0926\u0940 \u0922\u093e\u0902\u091a\u093e \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0905\u0928\u0941\u092d\u0935\u0940 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u0915\u093e\u092e \u0915\u0930\u0928\u093e \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0939\u0948\u0964 XBRELE \u0909\u091a\u094d\u091a-\u0938\u094d\u0924\u0930\u0940\u092f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0924\u0915\u0928\u0940\u0915 \u092e\u0947\u0902 \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e \u0939\u0948, \u091c\u094b \u091a\u0941\u0928\u094c\u0924\u0940\u092a\u0942\u0930\u094d\u0923 \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0914\u0930 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0924\u0948\u092f\u093e\u0930 \u0915\u0940 \u0917\u0908 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0915\u094d\u092f\u093e \u0906\u092a \u0905\u092a\u0928\u093e \u0905\u0917\u0932\u093e \u092a\u094d\u0930\u094b\u091c\u0947\u0915\u094d\u091f \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0924\u0948\u092f\u093e\u0930 \u0939\u0948\u0902?<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u091a\u092f\u0928, OEM \u0905\u0928\u0941\u0915\u0942\u0932\u0928 \u092a\u0930 \u091a\u0930\u094d\u091a\u093e \u0915\u0930\u0928\u0947 \u0914\u0930 \u0939\u092e\u093e\u0930\u0947 \u092a\u0930 \u0906\u092a\u0942\u0930\u094d\u0924\u093f\u0915\u0930\u094d\u0924\u093e \u0935\u093f\u0915\u0932\u094d\u092a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f XBRELE \u0915\u0940 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u091f\u0940\u092e \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0930\u0947\u0902\u0964 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker-manufacturers\/\"><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u092c\u0947\u0902\u091a\u092e\u093e\u0930\u094d\u0915<\/strong><\/a>, \u0914\u0930 \u0905\u092a\u0928\u0940 \u0936\u0949\u0930\u094d\u091f\u0932\u093f\u0938\u094d\u091f \u0915\u094b \u0915\u0947 \u0938\u093e\u0925 \u0938\u0902\u0930\u0947\u0916\u093f\u0924 \u0915\u0930\u0947\u0902 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker-ratings\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0947\u091f\u093f\u0902\u0917 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/a>.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Executive Summary: Engineering Quick View The Vacuum Circuit Breaker (VCB) is the globally accepted standard for medium-voltage switching, offering a maintenance-free and environmentally safe alternative to SF6 and Oil technologies. Voltage Class: Dominant in the 12 kV to 40.5 kV range for substations and heavy industry. Core Technology: Utilizes Metal Vapor Arc Extinction in [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2119,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2118","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2118","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2118"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2118\/revisions"}],"predecessor-version":[{"id":3538,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2118\/revisions\/3538"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2119"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2118"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2118"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2118"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}