{"id":2126,"date":"2025-12-16T12:58:10","date_gmt":"2025-12-16T12:58:10","guid":{"rendered":"https:\/\/xbrele.com\/?p=2126"},"modified":"2026-04-07T15:12:45","modified_gmt":"2026-04-07T15:12:45","slug":"sf6-load-break-switch-working-principle","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/sf6-load-break-switch-working-principle\/","title":{"rendered":"SF6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a (LBS) \u0915\u094d\u092f\u093e \u0939\u0948? \u090f\u0915 \u0928\u093f\u0930\u094d\u0923\u093e\u092f\u0915 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e"},"content":{"rendered":"<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"SF6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a \u0915\u094d\u092f\u093e \u0939\u0948? LBS \u092c\u0928\u093e\u092e VCB \u0915\u0940 \u0935\u094d\u092f\u093e\u0916\u094d\u092f\u093e\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/fvuUe-9gqZY?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #2c3e50; padding: 20px; margin: 20px 0; font-family: sans-serif; box-shadow: 0 2px 4px rgba(0,0,0,0.05);\"> <h3 style=\"color: #2c3e50; margin-top: 0; display: flex; align-items: center;\"> <span style=\"font-size: 1.2em; margin-right: 10px;\"><\/span> \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0915\u0947 \u092e\u0941\u0916\u094d\u092f \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937 <\/h3> <ul style=\"list-style-type: none; padding-left: 0; margin-bottom: 0;\"> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 \u090f\u0932\u092c\u0940\u090f\u0938 \u092c\u0928\u093e\u092e \u0935\u0940\u0938\u0940\u092c\u0940 \u0905\u0902\u0924\u0930:<\/strong> \u090f\u0915 \u090f\u0932\u092c\u0940\u090f\u0938 \u0915\u094b \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948 <em>\u0932\u094b\u0921 \u092a\u094d\u0930\u092c\u0902\u0927\u0928<\/em> (\u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u093e), \u091c\u092c\u0915\u093f \u090f\u0915 VCB \u090f\u0915 \u0939\u0948 <em>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923<\/em> \u0935\u093f\u0936\u093e\u0932 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0918\u091f\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f\u0964. <\/li> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 3-\u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0924\u0930\u094d\u0915:<\/strong> \u0906\u0927\u0941\u0928\u093f\u0915 \u0906\u0930\u090f\u092e\u092f\u0942 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0905\u0902\u0924\u0930-\u0932\u0949\u0915 \u0915\u093f\u090f \u0917\u090f \u0915\u094d\u0930\u092e (\u091a\u093e\u0932\u0942 \u2192 \u092c\u0902\u0926 \u2192 \u0905\u0930\u094d\u0925) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u093e\u0915\u093f \u092e\u093e\u0928\u0935 \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902, \u091c\u0948\u0938\u0947 \u0915\u093f \u091a\u093e\u0932\u0942 \u0932\u093e\u0907\u0928 \u0915\u094b \u0905\u0930\u094d\u0925 \u0915\u0930\u0928\u0947, \u0915\u094b \u092d\u094c\u0924\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0930\u094b\u0915\u093e \u091c\u093e \u0938\u0915\u0947\u0964. <\/li> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 \u092b\u094d\u092f\u0942\u091c \u0938\u092e\u0928\u094d\u0935\u092f:<\/strong> \u091a\u0942\u0902\u0915\u093f \u090f\u0932\u092c\u0940\u090f\u0938 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u094b \u0915\u094d\u0932\u093f\u092f\u0930 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u093e, \u0907\u0938\u0932\u093f\u090f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0907\u0938\u0947 \u0932\u0917\u092d\u0917 \u0939\u092e\u0947\u0936\u093e \u090f\u091a\u0906\u0930\u0938\u0940 \u092b\u094d\u092f\u0942\u091c\u093c (\u0938\u094d\u0935\u093f\u091a-\u092b\u094d\u092f\u0942\u091c\u093c \u0938\u0902\u092f\u094b\u091c\u0928) \u0915\u0947 \u0938\u093e\u0925 \u091c\u094b\u0921\u093c\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964. <\/li> <li> <strong>\ud83d\udd39 \u0936\u093e\u0938\u0940 \u092e\u093e\u0928\u0915:<\/strong> \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0938\u0916\u094d\u0924 \u0928\u093f\u092f\u092e\u0928 \u0926\u094d\u0935\u093e\u0930\u093e \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 <strong>\u0906\u0908\u0908\u0938\u0940 62271-103<\/strong> (\u0938\u094d\u0935\u093f\u091a) \u0914\u0930 <strong>\u0906\u0908\u0908\u0938\u0940 62271-105<\/strong> (\u0938\u094d\u0935\u093f\u091a-\u092b\u094d\u092f\u0942\u091c \u0938\u0902\u092f\u094b\u091c\u0928). <\/li> <\/ul> <\/div> <!-- END HTML BLOCK -->\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-introduction-the-lbs-vs-vcb-dilemma-in-network-design\">1. \u092a\u0930\u093f\u091a\u092f: \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u092e\u0947\u0902 LBS \u092c\u0928\u093e\u092e VCB \u0926\u0941\u0935\u093f\u0927\u093e<\/h2>\n\n\n\n<p>\u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0935\u093f\u0924\u0930\u0923 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0938\u093f\u0902\u0917\u0932 \u0932\u093e\u0907\u0928 \u0921\u093e\u092f\u0917\u094d\u0930\u093e\u092e (SLD) \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930 \u0930\u0939\u0947 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u090f\u0915 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0906\u0928\u0947 \u0935\u093e\u0932\u093e \u0928\u093f\u0930\u094d\u0923\u092f \u092c\u093f\u0902\u0926\u0941 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948: <strong>\u0939\u092e \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a (\u090f\u0932\u092c\u0940\u090f\u0938) \u0914\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940) \u0915\u0947 \u092c\u0940\u091a \u0930\u0947\u0916\u093e \u0915\u0939\u093e\u0901 \u0916\u0940\u0902\u091a\u0924\u0947 \u0939\u0948\u0902?<\/strong><\/p>\n\n\n\n<p>\u0926\u0943\u0936\u094d\u092f \u0930\u0942\u092a \u0938\u0947, \u0935\u0947 \u0905\u0915\u094d\u0938\u0930 \u092a\u0948\u0928\u0932 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u092a\u0930 \u090f\u0915 \u091c\u0948\u0938\u0947 \u0926\u093f\u0916\u0924\u0947 \u0939\u0948\u0902, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0905\u0928\u094d\u092f \u0915\u0947 \u0938\u093e\u0925 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/switchgear-components\/\"><strong>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915<\/strong><\/a>. \u0939\u093e\u0932\u093e\u0902\u0915\u093f, \u092f\u0939\u093e\u0901 \u0917\u0932\u0924 \u0909\u092a\u092f\u094b\u0917 \u0915\u0947\u0935\u0932 \u090f\u0915 \u0936\u092c\u094d\u0926\u093e\u0924\u094d\u092e\u0915 \u0924\u094d\u0930\u0941\u091f\u093f \u0928\u0939\u0940\u0902 \u0939\u0948; \u092f\u0939 \u090f\u0915 \u0917\u0902\u092d\u0940\u0930 \u091c\u094b\u0916\u093f\u092e \u0939\u0948\u0964 VCBs \u0915\u094b \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u093e \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0940 \u0932\u093e\u0917\u0924 \u0915\u094b \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092c\u0922\u093c\u093e \u0926\u0947\u0924\u093e \u0939\u0948 (\u0905\u0915\u094d\u0938\u0930 300% \u0924\u0915), \u091c\u092c\u0915\u093f \u0926\u094b\u0937-\u0928\u093f\u0935\u093e\u0930\u0923 \u092d\u0942\u092e\u093f\u0915\u093e \u092e\u0947\u0902 LBS \u0915\u094b \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0930\u0942\u092a \u0938\u0947 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u0905\u0902\u0924\u0930 \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c (MV) \u0935\u093f\u0924\u0930\u0923 \u0915\u093e \u0906\u0927\u093e\u0930 \u0939\u0948:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0926 <a href=\"https:\/\/xbrele.com\/hi\/what-is-vacuum-circuit-breaker-working-principle\/\"><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/strong><\/a> \u0915\u094d\u092f\u093e \u0906\u092a\u0915\u093e \u0917\u094d\u0930\u093f\u0921 \u0915\u093e <strong>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0924\u0902\u0924\u094d\u0930<\/strong>\u2014\u0935\u093f\u0936\u093e\u0932 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0926\u094b\u0937\u094b\u0902 (\u091c\u0948\u0938\u0947, 20kA, 31.5kA) \u0915\u094b \u092c\u093e\u0927\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u092f\u093e \u0917\u092f\u093e\u0964.<\/li>\n\n\n\n<li>\u0926 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/sf6-load-break-switch\/\"><strong>\u090f\u0938\u090f\u092b6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a<\/strong><\/a> \u0939\u0948 \u090f\u0915 <strong>\u0917\u094d\u0930\u093f\u0921 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0909\u092a\u0915\u0930\u0923<\/strong>\u2014\u0932\u094b\u0921 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u093f\u0924 \u0915\u0930\u0928\u0947, \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u0947 \u0916\u0902\u0921\u094b\u0902 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0928\u0947, \u0914\u0930 \u0926\u0943\u0936\u094d\u092f\u092e\u093e\u0928 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u092d\u093f\u0915\u0932\u094d\u092a\u093f\u0924\u0964.<\/li>\n<\/ul>\n\n\n\n<p>\u092f\u0939 \u0932\u0947\u0916 \u092e\u0942\u0932 \u092a\u0930\u093f\u092d\u093e\u0937\u093e\u0913\u0902 \u0938\u0947 \u092a\u0930\u0947 \u091c\u093e\u0915\u0930 SF6 LBS \u0915\u0940 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915\u0924\u093e \u0915\u093e \u0905\u0928\u094d\u0935\u0947\u0937\u0923 \u0915\u0930\u0924\u093e \u0939\u0948: \u0907\u0938\u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u092d\u094c\u0924\u093f\u0915\u0940, \u092f\u0939 \u0930\u093f\u0902\u0917 \u092e\u0947\u0928 \u092f\u0942\u0928\u093f\u091f\u094d\u0938 (RMUs) \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u0928\u0915 \u0915\u094d\u092f\u094b\u0902 \u092c\u0928\u093e \u0939\u0941\u0906 \u0939\u0948, \u0914\u0930 \u0907\u0938\u0947 \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0915\u0948\u0938\u0947 \u0932\u093e\u0917\u0942 \u0915\u093f\u092f\u093e \u091c\u093e\u090f\u0964 <strong>\u0906\u0908\u0908\u0938\u0940 62271<\/strong> \u092e\u093e\u0928\u0915\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-defining-the-sf6-load-break-switch-iec-62271-103\">2. SF6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a \u0915\u093e \u092a\u0930\u093f\u092d\u093e\u0937\u0928 (IEC 62271-103)<\/h2>\n\n\n\n<p>\u090f\u0915 <strong>\u090f\u0938\u090f\u092b6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a<\/strong> \u090f\u0915 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0909\u092a\u0915\u0930\u0923 \u0939\u0948 \u091c\u094b \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947, \u0935\u0939\u0928 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0938\u0915\u094d\u0937\u092e \u0939\u0948\u0964 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0930\u0942\u092a \u0938\u0947, \u0938\u0916\u094d\u0924\u0940 \u0938\u0947 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0926\u094d\u0935\u093e\u0930\u093e <strong>\u0906\u0908\u0908\u0938\u0940 62271-103<\/strong>, \u0907\u0938\u0947 \u092d\u0940 \u0938\u0915\u094d\u0937\u092e \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f <strong>\u092c\u0928\u093e\u0928\u093e<\/strong> \u090f\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u0930 (\u0926\u094b\u0937 \u092a\u0930 \u092c\u0902\u0926 \u0939\u094b\u0915\u0930) \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947, \u092d\u0932\u0947 \u0939\u0940 \u092f\u0939 \u0910\u0938\u093e \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u093e <strong>\u0924\u094b\u0921\u093c\u0928\u093e<\/strong> \u0935\u0939 \u0926\u094b\u0937.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-engineering-reality-of-load-breaking\">\u201c\u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917\u201d \u0915\u0940 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915\u0924\u093e\u201d<\/h3>\n\n\n\n<p>\u0936\u092c\u094d\u0926\u093e\u0935\u0932\u0940 \u0905\u0915\u094d\u0938\u0930 \u091c\u0942\u0928\u093f\u092f\u0930 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u094b \u092d\u094d\u0930\u092e\u093f\u0924 \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0906\u0907\u090f \u0924\u0940\u0928 \u092e\u0941\u0916\u094d\u092f \u0915\u094d\u0937\u092e\u0924\u093e\u0913\u0902 \u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 (\u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0927\u093e\u0930\u093e):<\/strong> \u0907\u0938\u0947 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0927\u093e\u0930\u093e (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f 24 kV \u092a\u0930 630 A) \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u090f\u0915 \u092a\u094d\u0930\u0947\u0930\u0915 \u092d\u093e\u0930 \u0915\u094b \u0924\u094b\u0921\u093c\u0928\u0947 \u092a\u0930 \u090f\u0915 \u0936\u0915\u094d\u0924\u093f\u0936\u093e\u0932\u0940 \u0906\u0930\u094d\u0915 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964  SF6 \u091c\u0948\u0938\u0947 \u0938\u0915\u094d\u0930\u093f\u092f \u0936\u092e\u0928 \u092e\u093e\u0927\u094d\u092f\u092e \u0915\u0947 \u092c\u093f\u0928\u093e, \u092f\u0939 \u0906\u0930\u094d\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0938\u0947\u0924\u0941 \u092c\u0928\u093e \u0932\u0947\u0917\u093e, \u0927\u093e\u0930\u093e \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0917\u093e \u0914\u0930 \u0938\u094d\u0935\u093f\u091a \u0915\u094b \u0928\u0937\u094d\u091f \u0915\u0930 \u0926\u0947\u0917\u093e\u0964.<\/li>\n\n\n\n<li><strong>\u0924\u094d\u0930\u0941\u091f\u093f \u0928\u093f\u0930\u094d\u092e\u093e\u0923 (\u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0928\u093f\u0930\u094d\u092e\u093e\u0923):<\/strong> \u092f\u0939 \u090f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u0947\u091f\u093f\u0902\u0917 \u0939\u0948\u0964 \u092f\u0926\u093f \u0915\u094b\u0908 \u0911\u092a\u0930\u0947\u091f\u0930 \u0917\u0932\u0924\u0940 \u0938\u0947 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0935\u093e\u0932\u0947 \u0915\u0947\u092c\u0932 \u092a\u0930 \u0938\u094d\u0935\u093f\u091a \u092c\u0902\u0926 \u0915\u0930 \u0926\u0947, \u0924\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u094b \u092b\u091f\u0928\u093e \u0928\u0939\u0940\u0902 \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938\u0947 \u0926\u094b\u0937 (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, 50 kA \u092a\u0940\u0915) \u0915\u0940 \u0935\u093f\u0936\u093e\u0932 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0936\u0915\u094d\u0924\u093f\u092f\u094b\u0902 \u0914\u0930 \u0924\u093e\u092a\u0940\u092f \u090a\u0930\u094d\u091c\u093e \u0915\u094b \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u092e\u092f \u0924\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0924\u093e\u0915\u093f \u0905\u092a\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091f\u094d\u0930\u093f\u092a \u0939\u094b \u0938\u0915\u0947\u0964.<\/li>\n\n\n\n<li><strong>\u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 (\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0917\u0948\u092a):<\/strong> \u0916\u0941\u0932\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902, \u0907\u0938\u0947 \u0921\u093e\u0909\u0928\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0917\u0948\u092a \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u091c\u094b \u0907\u092e\u094d\u092a\u0932\u094d\u0938 \u0935\u093f\u0925\u0938\u094d\u091f\u0948\u0902\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 (BIL) \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u093e \u0939\u094b\u0964.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-hard-limit-it-is-not-a-breaker\">\u0915\u0920\u094b\u0930 \u0938\u0940\u092e\u093e: \u092f\u0939 \u092c\u094d\u0930\u0947\u0915\u0930 \u0928\u0939\u0940\u0902 \u0939\u0948\u0964<\/h3>\n\n\n\n<p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0940\u092e\u093e \u0915\u094b \u0938\u092e\u091d\u0928\u093e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948: <strong>\u090f\u0915 \u090f\u0932\u092c\u0940\u090f\u0938 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u094b \u0928\u0939\u0940\u0902 \u0915\u093e\u091f \u0938\u0915\u0924\u093e\u0964.<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0924\u093f \u0914\u0930 \u0906\u0930\u094d\u0915-\u0928\u093f\u0937\u094d\u0915\u094d\u0930\u093f\u092f\u0923 \u090a\u0930\u094d\u091c\u093e \u0926\u094b\u0937 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0915\u093f\u0932\u094b\u090f\u092e\u094d\u092a\u093f\u092f\u0930 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0939\u0948\u0902\u0964 \u0926\u094b\u0937 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 LBS \u0916\u094b\u0932\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0915\u0930\u0928\u0947 \u092a\u0930 \u090a\u0937\u094d\u092e\u0940\u092f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923\u0939\u0940\u0928\u0924\u093e \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0935\u093f\u0938\u094d\u092b\u094b\u091f \u0939\u094b\u0917\u093e\u0964.<\/p>\n\n\n\n<p>\u092f\u0939\u0940 \u0915\u093e\u0930\u0923 \u0939\u0948 \u0915\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092b\u0940\u0921\u0930\u094b\u0902 \u092e\u0947\u0902 LBS \u0907\u0915\u093e\u0907\u092f\u093e\u0901 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0930\u0942\u092a \u0938\u0947 \u0915\u0947 \u0938\u093e\u0925 \u091c\u094b\u0921\u093c\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948\u0902\u0964 <strong>\u090f\u091a\u0906\u0930\u0938\u0940 \u092b\u094d\u092f\u0942\u091c\u093c<\/strong>. \u092b\u094d\u092f\u0942\u091c \u0926\u094b\u0937 \u0928\u093f\u0915\u093e\u0938\u0940 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f \u0938\u094d\u0935\u093f\u091a \u092e\u0948\u0928\u0941\u0905\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0902\u092d\u093e\u0932\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u0926\u0930\u094d\u092d:<\/strong> \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0930\u093f\u092d\u093e\u0937\u093e\u0913\u0902 \u092e\u0947\u0902 \u0917\u0939\u0930\u0940 \u091c\u093e\u0928\u0915\u093e\u0930\u0940 \u0915\u0947 \u0932\u093f\u090f, \u0938\u0902\u0926\u0930\u094d\u092d \u0932\u0947\u0902\u0964 <a href=\"https:\/\/www.electropedia.org\/iev\/iev.nsf\/display?openform&amp;ievref=441-14-10\" target=\"_blank\" rel=\"noopener\"><strong>\u0906\u0908\u0908\u0938\u0940 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u092a\u0940\u0921\u093f\u092f\u093e (\u0905\u0902\u0924\u0930\u094d\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u092a\u094d\u0930\u093e\u0935\u093f\u0927\u093f\u0915 \u0936\u092c\u094d\u0926\u093e\u0935\u0932\u0940)<\/strong><\/a> \u201c\u0938\u094d\u0935\u093f\u091a-\u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f\u0930\u094d\u0938\u201d \u092a\u0930 \u092e\u093e\u0928\u0915 \u0936\u092c\u094d\u0926\u093e\u0935\u0932\u0940 \u0915\u0947 \u0932\u093f\u090f\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-the-physics-of-sf6-why-it-dominated-for-40-years\">3. SF6 \u0915\u093e \u092d\u094c\u0924\u093f\u0915 \u0935\u093f\u091c\u094d\u091e\u093e\u0928: 40 \u0935\u0930\u094d\u0937\u094b\u0902 \u0924\u0915 \u0907\u0938\u0915\u093e \u092a\u094d\u0930\u092d\u0941\u0924\u094d\u0935 \u0915\u094d\u092f\u094b\u0902 \u0930\u0939\u093e<\/h2>\n\n\n\n<p>\u0939\u092e \u0905\u092d\u0940 \u092d\u0940 \u0915\u093f\u0938 \u092a\u0930 \u092d\u0930\u094b\u0938\u093e \u0915\u094d\u092f\u094b\u0902 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 <strong>\u0938\u0932\u094d\u092b\u0930 \u0939\u0947\u0915\u094d\u0938\u093e\u092b\u094d\u0932\u094b\u0930\u093e\u0907\u0921 (\u090f\u0938\u090f\u092b6)<\/strong> \u0915\u0920\u094b\u0930 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u091c\u093e\u0902\u091a \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926? \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092d\u094c\u0924\u093f\u0915 \u0930\u0942\u092a \u0938\u0947, \u0935\u093e\u092f\u0941 \u092f\u093e \u0924\u0947\u0932 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f \u0905\u0935\u0930\u094b\u0927\u0915 \u092e\u093e\u0927\u094d\u092f\u092e \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u092f\u0939 \u0932\u0917\u092d\u0917 \u0905\u0924\u0941\u0932\u0928\u0940\u092f \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-electronegativity-and-electron-attachment\">1. \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928 \u0928\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915\u0924\u093e \u0914\u0930 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928 \u0938\u0902\u0932\u0917\u094d\u0928\u0924\u093e<\/h3>\n\n\n\n<p>SF6 \u090f\u0915 \u201c\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u0928\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915\u201d \u0917\u0948\u0938 \u0939\u0948\u0964 \u0907\u0938\u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0915\u093f \u0907\u0938\u0915\u0947 \u0905\u0923\u0941\u0913\u0902 \u092e\u0947\u0902 \u092e\u0941\u0915\u094d\u0924 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0909\u091a\u094d\u091a \u0906\u0915\u0930\u094d\u0937\u0923 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u091c\u092c \u090f\u0915 \u0906\u0930\u094d\u0915 \u092c\u0928\u0924\u093e \u0939\u0948 (\u091c\u094b \u092e\u0942\u0932\u0924\u0903 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0915\u0940 \u090f\u0915 \u0927\u093e\u0930\u093e \u0939\u0948), \u0924\u094b SF6 \u0905\u0923\u0941 \u0907\u0928 \u092e\u0941\u0915\u094d\u0924 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0915\u094b \u0917\u094d\u0930\u0939\u0923 \u0915\u0930\u0915\u0947 \u092d\u093e\u0930\u0940 \u090b\u0923\u093e\u0924\u094d\u092e\u0915 \u0906\u092f\u0928 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<p style=\"text-align: center; font-family: 'Times New Roman', serif; font-size: 1.3em; margin: 20px 0;\"> \u090f\u0938\u090f\u092b<sub>6<\/sub> + \u0908<sup>\u2013<\/sup> \u2192 \u090f\u0938\u090f\u092b<sub>6<\/sub><sup>\u2013<\/sup> <\/p>\n\n\n\n<p>\u092f\u0947 \u092d\u093e\u0930\u0940 \u0906\u092f\u0928 \u092e\u0941\u0915\u094d\u0924 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u092c\u0939\u0941\u0924 \u0915\u092e \u0917\u0924\u093f\u0936\u0940\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0906\u0930\u094d\u0915 \u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e \u0915\u0940 \u091a\u093e\u0932\u0915\u0924\u093e \u092e\u0947\u0902 \u092d\u093e\u0930\u0940 \u0915\u092e\u0940 \u0906 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0930\u0942\u092a \u0938\u0947 \u0906\u0930\u094d\u0915 \u0915\u094b \u0909\u0938\u0915\u0947 \u091a\u093e\u0932\u0915 \u092e\u093e\u0930\u094d\u0917 \u0938\u0947 \u0935\u0902\u091a\u093f\u0924 \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-thermal-conductivity-at-high-temperatures\">2. \u0909\u091a\u094d\u091a \u0924\u093e\u092a\u092e\u093e\u0928 \u092a\u0930 \u090a\u0937\u094d\u092e\u0940\u092f \u091a\u093e\u0932\u0915\u0924\u093e<\/h3>\n\n\n\n<p>SF6 \u092e\u0947\u0902 \u090f\u0915 \u0905\u0928\u0942\u0920\u0940 \u0935\u093f\u0936\u0947\u0937\u0924\u093e \u0939\u0948 \u0915\u093f \u0907\u0938\u0915\u0940 \u0924\u093e\u092a\u0940\u092f \u091a\u093e\u0932\u0915\u0924\u093e \u0906\u0930\u094d\u0915 \u0935\u093f\u0918\u091f\u0928 \u0924\u093e\u092a\u092e\u093e\u0928 (\u0932\u0917\u092d\u0917 2000K\u20133000K) \u092a\u0930 \u0924\u0940\u0935\u094d\u0930\u0924\u093e \u0938\u0947 \u092c\u0922\u093c \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u0907\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0938\u0947 \u0917\u0930\u094d\u092e\u0940 \u0915\u094b \u0939\u0935\u093e \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0915\u0941\u0936\u0932\u0924\u093e \u0938\u0947 \u0926\u0942\u0930 \u0932\u0947 \u091c\u093e\u0928\u0947 \u092e\u0947\u0902 \u0938\u0915\u094d\u0937\u092e \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0924\u0940\u0935\u094d\u0930 \u0936\u0940\u0924\u0932\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 <strong>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f<\/strong>\u2014\u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u093e \u0915\u093f \u091c\u092c \u090f\u0938\u0940 \u0927\u093e\u0930\u093e \u201c\u0936\u0942\u0928\u094d\u092f\u201d \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u0924\u0940 \u0939\u0948, \u0924\u094b \u0935\u0939 \u0917\u0948\u092a \u0905\u092a\u0928\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u094b \u0909\u0938 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u092c\u0922\u093c\u0928\u0947 \u0915\u0940 \u0917\u0924\u093f \u0938\u0947 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947 \u092a\u0941\u0928\u0903 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930 \u0932\u0947 (\u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0935\u094b\u0932\u094d\u091f\u0947\u091c)\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-chemical-recombination\">3. \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u092a\u0941\u0928\u0930\u094d\u0938\u0902\u092f\u094b\u091c\u0928<\/h3>\n\n\n\n<p>\u0924\u0947\u0932 \u0915\u0947 \u0935\u093f\u092a\u0930\u0940\u0924, \u091c\u094b \u0915\u093e\u0930\u094d\u092c\u0928 \u0938\u094d\u0932\u091c \u092e\u0947\u0902 \u0905\u092a\u0918\u091f\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u092f\u093e \u0939\u0935\u093e, \u091c\u094b \u0913\u091c\u093c\u094b\u0928 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948, SF6 \u0917\u0948\u0938 \u0906\u0930\u094d\u0915 \u092c\u0941\u091d\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u092a\u0941\u0928\u0903 \u0938\u0902\u092f\u094b\u091c\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p style=\"text-align: center; font-family: 'Times New Roman', serif; font-size: 1.3em; margin: 20px 0;\"> \u090f\u0938\u090f\u092b<sub>6<\/sub> \u2194 S + 6F <\/p>\n\n\n\n<p>\u090f\u0915 \u092c\u093e\u0930 \u091c\u092c \u0906\u0930\u094d\u0915 \u0920\u0902\u0921\u093e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0938\u0932\u094d\u092b\u0930 \u0914\u0930 \u092b\u094d\u0932\u094b\u0930\u0940\u0928 \u0915\u0947 \u092a\u0930\u092e\u093e\u0923\u0941 \u092a\u0941\u0928\u0903 \u092e\u093f\u0932\u0915\u0930 \u0938\u094d\u0925\u093f\u0930 SF6 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0939 \u201c\u0938\u094d\u0935-\u092e\u0930\u092e\u094d\u092e\u0924\u201d \u0917\u0941\u0923 \u090f\u0915 \u0938\u0940\u0932\u092c\u0902\u0926 LBS \u0915\u094b \u092c\u093f\u0928\u093e \u0917\u0948\u0938 \u0930\u093f\u092b\u093f\u0932 \u0915\u0947 20 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0935\u0930\u094d\u0937\u094b\u0902 \u0924\u0915 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-the-design-logic-why-rmus-rely-on-lbs\">4. \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0924\u0930\u094d\u0915: \u0906\u0930\u090f\u092e\u092f\u0942 \u090f\u0932\u092c\u0940\u090f\u0938 \u092a\u0930 \u0915\u094d\u092f\u094b\u0902 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902<\/h2>\n\n\n\n<p>\u092f\u0926\u093f \u090f\u0915 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\"><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/strong><\/a> \u091c\u094b \u0932\u094b\u0921 \u0914\u0930 \u092b\u0949\u0932\u094d\u091f \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0909\u0928\u094d\u0939\u0947\u0902 \u0938\u093e\u0930\u094d\u0935\u092d\u094c\u092e\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0915\u094d\u092f\u094b\u0902 \u0928\u0939\u0940\u0902 \u0907\u0938\u094d\u0924\u0947\u092e\u093e\u0932 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e? \u0907\u0938\u0915\u093e \u0909\u0924\u094d\u0924\u0930 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u091f\u094b\u092a\u094b\u0932\u0949\u091c\u0940 \u0914\u0930 \u092a\u0942\u0902\u091c\u0940\u0917\u0924 \u0935\u094d\u092f\u092f (CAPEX) \u0926\u0915\u094d\u0937\u0924\u093e \u092e\u0947\u0902 \u0928\u093f\u0939\u093f\u0924 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-ring-topology-argument\">\u0930\u093f\u0902\u0917 \u091f\u094b\u092a\u094b\u0932\u0949\u091c\u0940 \u0924\u0930\u094d\u0915<\/h3>\n\n\n\n<p>\u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0935\u093f\u0924\u0930\u0923 \u092e\u0947\u0902 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0930\u093f\u0921\u0902\u0921\u0947\u0902\u0938\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u0902\u0917 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u090f\u0915 \u092e\u093e\u0928\u0915 \u0930\u093f\u0902\u0917 \u092e\u0947\u0928 \u092f\u0942\u0928\u093f\u091f (RMU) \u092e\u0947\u0902 \u0906\u092a\u0915\u094b \u201cCCF\u201d \u0915\u0949\u0928\u094d\u092b\u093c\u093f\u0917\u0930\u0947\u0936\u0928 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947 \u0938\u0915\u0924\u093e \u0939\u0948: \u0926\u094b \u0915\u0947\u092c\u0932 \u0938\u094d\u0935\u093f\u091a \u0914\u0930 \u090f\u0915 \u092b\u094d\u092f\u0942\u091c \u0938\u094d\u0935\u093f\u091a\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0915\u0947\u092c\u0932 \u0938\u094d\u0935\u093f\u091a (\u0938\u0940-\u092e\u0949\u0921\u094d\u092f\u0942\u0932):<\/strong> \u092f\u0947 \u0906\u0930\u090f\u092e\u092f\u0942 \u0915\u094b \u092e\u0941\u0916\u094d\u092f \u090f\u092e\u0935\u0940 \u0930\u093f\u0902\u0917 \u0938\u0947 \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938 \u092e\u0941\u0916\u094d\u092f \u0930\u093f\u0902\u0917 \u092e\u0947\u0902 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0916\u0930\u093e\u092c\u0940 \u0909\u091a\u094d\u091a-\u090a\u0930\u094d\u091c\u093e \u0918\u091f\u0928\u093e\u090f\u0901 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u0915\u0947 \u0930\u093f\u0932\u0947 \u0938\u0902\u092d\u093e\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0906\u0930\u090f\u092e\u092f\u0942 \u0915\u094b \u0907\u0928 \u0930\u093f\u0902\u0917 \u0916\u0930\u093e\u092c\u0940\u092f\u094b\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u0939\u0948; \u0907\u0938\u0947 \u0915\u0947\u0935\u0932 \u090f\u0915 \u0916\u0902\u0921 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964 <em>\u0915\u0947 \u092c\u093e\u0926<\/em> \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u091f\u094d\u0930\u093f\u092a \u0939\u094b \u0917\u092f\u093e \u0939\u0948, \u092f\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0932\u094b\u0921 \u0938\u094d\u0925\u093e\u0928\u093e\u0902\u0924\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964. <strong>\u090f\u0915 LBS \u0907\u0938 \u0915\u093e\u0930\u094d\u092f \u0915\u094b VCB \u0915\u0940 \u0932\u093e\u0917\u0924 \u0915\u0947 30% \u092a\u0930 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/strong><\/li>\n\n\n\n<li><strong>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092b\u0940\u0921\u0930 (\u090f\u092b-\u092e\u0949\u0921\u094d\u092f\u0942\u0932):<\/strong> \u092f\u0939 \u090f\u0915 \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0915\u0940 \u0930\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u093e \u0939\u0948 <a href=\"https:\/\/xbrele.com\/hi\/distribution-transformer-guide\/\"><strong>\u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930<\/strong><\/a> (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, 500kVA)\u0964 \u092f\u0939\u093e\u0902 \u090f\u0915 \u0935\u093f\u0936\u0947\u0937 LBS-\u092b\u094d\u092f\u0942\u091c \u0938\u0902\u092f\u094b\u091c\u0928 \u092a\u0942\u0930\u094d\u0923 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0906\u0930\u094d\u0925\u093f\u0915 \u0939\u0948, \u091c\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u092a\u0930 \u0926\u0947\u0916\u0940 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u0940\u092e\u093f\u0924 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-footprint-advantage\">\u092b\u0941\u091f\u092a\u094d\u0930\u093f\u0902\u091f \u0915\u093e \u0932\u093e\u092d<\/h3>\n\n\n\n<p>\u0936\u0939\u0930\u0940 \u0905\u0935\u0938\u0902\u0930\u091a\u0928\u093e \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u0928 \u0939\u0940 \u092e\u0941\u0926\u094d\u0930\u093e \u0939\u0948\u0964 \u090f\u0915 \u092e\u093e\u0928\u0915 VCB \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u0915\u094b \u092d\u093e\u0930\u0940 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917 \u092e\u094b\u091f\u0930\u094d\u0938) \u0914\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092c\u094b\u0924\u0932\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u090f\u0915 SF6 LBS \u0917\u0948\u0938 \u0915\u0940 \u0909\u091a\u094d\u091a \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0906\u0907\u0938\u094b\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u092e\u0924\u093e (\u0935\u093e\u092f\u0941 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 2.5 \u0917\u0941\u0928\u093e) \u0915\u093e \u0932\u093e\u092d \u0909\u0920\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092b\u0947\u091c-\u091f\u0942-\u092b\u0947\u091c \u0915\u094d\u0932\u093f\u092f\u0930\u0947\u0902\u0938 \u0915\u094b \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 <strong>\u0917\u0948\u0938-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 (\u091c\u0940\u0906\u0908\u090f\u0938)<\/strong> \u091c\u094b \u0938\u0902\u0915\u0940\u0930\u094d\u0923 \u092b\u0941\u091f\u092a\u093e\u0925 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092f\u093e \u092a\u0935\u0928 \u091f\u0930\u092c\u093e\u0907\u0928 \u091f\u093e\u0935\u0930\u094b\u0902 \u0915\u0947 \u0905\u0902\u0926\u0930 \u092b\u093f\u091f \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u2014\u0910\u0938\u0940 \u091c\u0917\u0939\u0947\u0902 \u091c\u0939\u093e\u0901 \u092a\u093e\u0930\u0902\u092a\u0930\u093f\u0915 \u090f\u092f\u0930-\u0907\u0902\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092c\u0938 \u092b\u093f\u091f \u0928\u0939\u0940\u0902 \u0939\u094b \u092a\u093e\u0924\u093e\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-operational-mechanics-puffer-vs-rotating-arc\">5. \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940: \u092a\u092b\u093c\u0930 \u092c\u0928\u093e\u092e \u0918\u0942\u0930\u094d\u0923\u0928 \u091a\u093e\u092a<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram.webp\" alt=\"\u090f\u0915 \u090f\u0938\u090f\u092b6 \u0917\u0948\u0938 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u091f\u0948\u0902\u0915 \u0915\u093e \u0924\u0915\u0928\u0940\u0915\u0940 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u092c\u094d\u0932\u0942\u092a\u094d\u0930\u093f\u0902\u091f \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928\u0964 \u0909\u091a\u094d\u091a \u0915\u0902\u091f\u094d\u0930\u093e\u0938\u094d\u091f, \u0938\u092b\u0947\u0926 \u092a\u0943\u0937\u094d\u0920\u092d\u0942\u092e\u093f\u0964 \u0935\u0947\u0915\u094d\u091f\u0930 \u0936\u0948\u0932\u0940 \u0915\u093e \u091a\u093f\u0924\u094d\u0930\u0923\u0964 \u0924\u0940\u0928 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948: 1. \u092c\u0902\u0926 \u0938\u0930\u094d\u0915\u093f\u091f, 2. \u0916\u0941\u0932\u093e \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0917\u0948\u092a, 3. \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u0941\u0921\u093c\u093e \u0939\u0941\u0906\u0964 \u0932\u0947\u092c\u0932 \u0915\u093f\u090f \u0917\u090f \u092d\u093e\u0917: &quot;\u092e\u094b\u0935\u093f\u0902\u0917 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f&quot;, &quot;\u092b\u093f\u0915\u094d\u0938\u094d\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f&quot;, &quot;\u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a&quot;\u0964 \u0924\u0915\u0928\u0940\u0915\u0940, \u092f\u094b\u091c\u0928\u093e\u092c\u0926\u094d\u0927, \u0938\u091f\u0940\u0915 \u0932\u093e\u0907\u0928 \u0906\u0930\u094d\u091f\u0964.\" class=\"wp-image-2131\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0938\u094d\u0935\u093f\u091a \u0935\u093e\u0938\u094d\u0924\u0935 \u092e\u0947\u0902 \u0906\u0930\u094d\u0915 \u0915\u094b \u0915\u0948\u0938\u0947 \u0916\u0924\u094d\u092e \u0915\u0930\u0924\u093e \u0939\u0948? \u092f\u0939 \u0938\u093f\u0930\u094d\u092b \u0938\u0902\u092a\u0930\u094d\u0915 \u0916\u094b\u0932\u0928\u0947 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u0928\u0939\u0940\u0902 \u0939\u0948; \u092f\u0939 \u0917\u0948\u0938 \u091f\u0948\u0902\u0915 \u0915\u0947 \u0905\u0902\u0926\u0930 \u0924\u0930\u0932 \u0917\u0924\u093f\u0915\u0940 \u0915\u0947 \u092c\u093e\u0930\u0947 \u092e\u0947\u0902 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technique-a-puffer-type-the-standard\">\u0924\u0915\u0928\u0940\u0915 A: \u092a\u092b\u093c\u0930 \u092a\u094d\u0930\u0915\u093e\u0930 (\u092e\u093e\u0928\u0915)<\/h3>\n\n\n\n<p>\u092f\u0939 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0938\u092c\u0938\u0947 \u0906\u092e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0939\u0948\u0964.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u092a\u0940\u0921\u093c\u0928:<\/strong> \u091c\u0948\u0938\u0947 \u0939\u0940 \u0938\u0902\u091a\u093e\u0932\u0928 \u0935\u0938\u0902\u0924 \u091b\u094b\u0921\u093c\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u091a\u0932\u0924\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0947 \u091c\u0941\u0921\u093c\u093e \u092a\u093f\u0938\u094d\u091f\u0928 \u090f\u0915 \u091b\u094b\u091f\u0947 \u0938\u093f\u0932\u0947\u0902\u0921\u0930 \u0915\u0947 \u0905\u0902\u0926\u0930 SF6 \u0917\u0948\u0938 \u0915\u094b \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0930\u093f\u0932\u0940\u091c:<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0905\u0932\u0917 \u0939\u094b\u0928\u0947 \u0914\u0930 \u0906\u0930\u094d\u0915 \u0915\u0947 \u092c\u0928\u0928\u0947 \u0915\u0947 \u0920\u0940\u0915 \u0909\u0938\u0940 \u0915\u094d\u0937\u0923, \u090f\u0915 \u0928\u094b\u091c\u0932 \u0907\u0938 \u0938\u0902\u092a\u0940\u0921\u093c\u093f\u0924 \u0917\u0948\u0938 \u0915\u094b \u0906\u0930\u094d\u0915 \u0938\u094d\u0924\u0902\u092d \u0915\u0947 \u0938\u093e\u0925 \u0905\u0915\u094d\u0937\u0940\u092f \u0930\u0942\u092a \u0938\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f:<\/strong> \u0909\u091a\u094d\u091a \u0935\u0947\u0917 \u0935\u093e\u0932\u0940 \u0917\u0948\u0938 \u0915\u093e \u092a\u094d\u0930\u0935\u093e\u0939 \u0906\u0930\u094d\u0915 \u0915\u094b \u0932\u0902\u092c\u093e \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948 \u0914\u0930 \u0909\u0938\u0947 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0920\u0902\u0921\u093e \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u092b\u093f\u0930 \u0938\u0947 \u0932\u0917\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0917\u0948\u092a \u0915\u093e \u0906\u092f\u0928\u0940\u0915\u0930\u0923 \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technique-b-rotating-arc-principle\">\u0924\u0915\u0928\u0940\u0915 \u092c\u0940: \u0918\u0942\u0930\u094d\u0923\u0928 \u091a\u093e\u092a \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924<\/h3>\n\n\n\n<p>\u092d\u093e\u0930\u0940-\u0915\u0930\u094d\u0924\u0935\u094d\u092f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092f\u093e \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u092c\u094d\u0930\u093e\u0902\u0921\u094b\u0902 (\u091c\u0948\u0938\u0947 \u0936\u094d\u0928\u093e\u0907\u0921\u0930 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0915\u0940 \u092a\u0941\u0930\u093e\u0928\u0940 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e\u090f\u0901) \u092e\u0947\u0902 \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u092f\u0939 \u0924\u0930\u0940\u0915\u093e \u0938\u094d\u0935\u092f\u0902 \u0906\u0930\u094d\u0915 \u0915\u0940 \u090a\u0930\u094d\u091c\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930:<\/strong> \u0938\u094d\u0935\u093f\u091a \u0938\u0947 \u092c\u0939\u0928\u0947 \u0935\u093e\u0932\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0927\u093e\u0930\u093e \u090f\u0915 \u0915\u0941\u0902\u0921\u0932\u0940 \u0938\u0947 \u0939\u094b\u0915\u0930 \u0917\u0941\u091c\u0930\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u090f\u0915 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0932\u0949\u0440\u0435\u043d\u094d\u091c\u093c \u092c\u0932:<\/strong> \u092f\u0939 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0906\u0930\u094d\u0915 \u092a\u094d\u0932\u093e\u091c\u094d\u092e\u093e (\u091c\u094b \u0927\u093e\u0930\u093e \u0935\u0939\u0928 \u0915\u0930\u0924\u093e \u0939\u0948) \u092a\u0930 \u092c\u0932 \u0932\u0917\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0930 SF6 \u0917\u0948\u0938 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0924\u0947\u091c\u0940 \u0938\u0947 \u0935\u0943\u0924\u094d\u0924\u094b\u0902 \u092e\u0947\u0902 \u0918\u0942\u092e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0915\u0942\u0932\u093f\u0902\u0917:<\/strong> \u092f\u0939 \u090f\u0915 \u201c\u0938\u094d\u091f\u093f\u0930\u0930\u201d \u0915\u0940 \u0924\u0930\u0939 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u0906\u0930\u094d\u0915 \u0915\u094b \u0932\u0917\u093e\u0924\u093e\u0930 \u0924\u093e\u091c\u093c\u0947, \u0920\u0902\u0921\u0947 \u0917\u0948\u0938 \u092e\u0947\u0902 \u091c\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092e\u091c\u092c\u0942\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u091c\u093f\u0924\u0928\u0940 \u0905\u0927\u093f\u0915 \u0939\u094b\u0917\u0940, \u0918\u0942\u0930\u094d\u0923\u0928 \u0909\u0924\u0928\u093e \u0939\u0940 \u0924\u0947\u091c\u093c \u0939\u094b\u0917\u093e, \u091c\u093f\u0938\u0938\u0947 \u092f\u0939 \u090f\u0915 \u0938\u094d\u0935-\u0905\u0928\u0941\u0915\u0942\u0932\u093f\u0924 \u0936\u092e\u0928 \u0935\u093f\u0927\u093f \u092c\u0928 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-the-three-position-standard-on-off-earth\">6. \u0924\u0940\u0928-\u0938\u094d\u0925\u093f\u0924\u093f \u092e\u093e\u0928\u0915: \u091a\u093e\u0932\u0942 \u2013 \u092c\u0902\u0926 \u2013 \u092a\u0943\u0925\u094d\u0935\u0940<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"2560\" height=\"1396\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-scaled.webp\" alt=\"SF6 \u0917\u0948\u0938 \u092e\u0947\u0902 \u092a\u092b\u0930 \u0906\u0930\u094d\u0915 \u0936\u092e\u0928 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0915\u093e \u0926\u0943\u0936\u094d\u092f\u093e\u0902\u0915\u0928\u0964.\" class=\"wp-image-2132\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-scaled.webp 2560w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-1024x559.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-1536x838.webp 1536w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-2048x1117.webp 2048w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-18x10.webp 18w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n\n\n\n<p>\u0906\u0927\u0941\u0928\u093f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093e\u0928\u0915\u094b\u0902 (IEC 62271-200) \u0928\u0947 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0930\u0942\u092a \u0938\u0947 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0915\u0930 \u0926\u093f\u092f\u093e \u0939\u0948 \u0915\u093f <strong>\u0924\u0940\u0928-\u0938\u094d\u0925\u093f\u0924\u093f \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u0915<\/strong> \u0917\u0948\u0938-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902\u0964 \u092f\u0939 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0914\u0930 \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0905\u0932\u0917-\u0905\u0932\u0917 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0915\u0940 \u092a\u0941\u0930\u093e\u0928\u0940 \u092a\u0926\u094d\u0927\u0924\u093f \u0915\u094b \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091c\u091f\u093f\u0932 \u0915\u0940 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938 \u092a\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0928\u093f\u0930\u094d\u092d\u0930 \u0925\u0940\u0964.<\/p>\n\n\n\n<p>\u0924\u0940\u0928 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u090f\u0915\u0932 \u0936\u093e\u092b\u094d\u091f \u092f\u093e \u092a\u0930\u0938\u094d\u092a\u0930-\u092c\u0902\u0927\u093f\u0924 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u092e\u0947\u0902 \u090f\u0915\u0940\u0915\u0943\u0924 \u0915\u0940 \u0917\u0908 \u0939\u0948\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u092c\u0902\u0926 (\u091a\u093e\u0932\u0942):<\/strong> \u092e\u0941\u0916\u094d\u092f \u0938\u0930\u094d\u0915\u093f\u091f \u091c\u0941\u0921\u093c\u093e \u0939\u0941\u0906\u0964.<\/li>\n\n\n\n<li><strong>\u0916\u0941\u0932\u093e (\u092c\u0902\u0926):<\/strong> \u0938\u0930\u094d\u0915\u093f\u091f \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u093f\u0924, \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0926\u0942\u0930\u0940 \u0915\u0947 \u0938\u093e\u0925\u0964.<\/li>\n\n\n\n<li><strong>\u092a\u0943\u0925\u094d\u0935\u0940 (\u092a\u0943\u0925\u094d\u0935\u0940):<\/strong> \u0915\u0947\u092c\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0938\u0947 \u0936\u0949\u0930\u094d\u091f \u0939\u094b \u0917\u090f\u0964.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-engineering-advantage\">\u0905\u092d\u093f\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940 \u0915\u093e \u0932\u093e\u092d<\/h3>\n\n\n\n<p>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0907\u0938\u0947 \u092d\u094c\u0924\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0905\u0938\u0902\u092d\u0935 \u092c\u0928\u093e \u0926\u0947\u0924\u093e \u0939\u0948 \u0915\u093f \u0938\u0947 \u091c\u093e\u090f\u0901\u0964 <strong>\u091a\u093e\u0932\u0942<\/strong> \u0938\u0940\u0927\u0947 <strong>\u092a\u0943\u0925\u094d\u0935\u0940<\/strong>. \u0906\u092a\u0915\u094b \u0917\u0941\u091c\u0930\u0928\u093e \u0939\u094b\u0917\u093e <strong>\u092c\u0902\u0926<\/strong>. \u092f\u0939 \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0939\u093f\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0932\u093e\u0907\u0935 \u0932\u093e\u0907\u0928 \u0915\u094b \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0930\u0928\u0947 \u0915\u0940 \u201c\u092e\u093e\u0928\u0935\u0940\u092f \u0924\u094d\u0930\u0941\u091f\u093f\u201d \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u0930\u094b\u0915\u0924\u0940 \u0939\u0948, \u091c\u094b \u092a\u0941\u0930\u093e\u0928\u0947 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 \u092c\u093f\u091c\u0932\u0940 \u0926\u0941\u0930\u094d\u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u093e \u090f\u0915 \u092a\u094d\u0930\u092e\u0941\u0916 \u0915\u093e\u0930\u0923 \u0939\u0948\u0964.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0918\u091f\u0915:<\/strong> \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u092a\u0930 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e\u093e\u0930\u0947 \u0926\u0947\u0916\u0947\u0902\u0964 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/earthing-switch\/\"><strong>\u0907\u0928\u0921\u094b\u0930 HV \u0905\u0930\u094d\u0925\u093f\u0902\u0917 \u0938\u094d\u0935\u093f\u091a (JN15 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e)<\/strong><\/a> \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0905\u0915\u094d\u0938\u0930 \u0907\u0928 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u0935\u093e\u092f\u0941-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0938\u0902\u0938\u094d\u0915\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u090f\u0915\u0940\u0915\u0943\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-switch-fuse-coordination-the-striker-mechanism\">7. \u0938\u094d\u0935\u093f\u091a-\u092b\u094d\u092f\u0942\u091c \u0938\u092e\u0928\u094d\u0935\u092f: \u201c\u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915\u0930\u201d \u0924\u0902\u0924\u094d\u0930<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism.webp\" alt=\"HRC \u092b\u094d\u092f\u0942\u091c \u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915\u0930 \u092a\u093f\u0928 \u0926\u094d\u0935\u093e\u0930\u093e \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a \u0924\u0902\u0924\u094d\u0930 \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0930\u0928\u0947 \u0915\u093e \u091a\u093f\u0924\u094d\u0930\u0923\u0964.\" class=\"wp-image-2133\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u090f\u0932\u092c\u0940\u090f\u0938 \u0915\u093e \u0938\u092c\u0938\u0947 \u0924\u0915\u0928\u0940\u0915\u0940 \u0930\u0942\u092a \u0938\u0947 \u0930\u094b\u091a\u0915 \u092a\u0939\u0932\u0941\u0913\u0902 \u092e\u0947\u0902 \u0938\u0947 \u090f\u0915 \u092f\u0939 \u0939\u0948 \u0915\u093f \u091c\u092c \u0907\u0938\u0947 \u092b\u094d\u092f\u0942\u091c\u093c \u0915\u0947 \u0938\u093e\u0925 \u091c\u094b\u0921\u093c\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u0924\u094b \u092f\u0939 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0928\u0915\u0932 \u0915\u0948\u0938\u0947 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948 <strong>\u0906\u0908\u0908\u0938\u0940 62271-105<\/strong>.<\/p>\n\n\n\n<p>\u201c\u0938\u094d\u0935\u093f\u091a-\u092b\u094d\u092f\u0942\u091c \u0938\u0902\u092f\u094b\u091c\u0928\u201d \u092e\u0947\u0902, LBS \u0924\u0902\u0924\u094d\u0930 \u0915\u0947\u0935\u0932 \u092e\u0948\u0928\u0941\u0905\u0932 \u0928\u0939\u0940\u0902 \u0939\u0948; \u0907\u0938\u092e\u0947\u0902 \u090f\u0915 \u0938\u0902\u0917\u094d\u0930\u0939\u093f\u0924-\u090a\u0930\u094d\u091c\u093e \u0935\u093e\u0932\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0939\u094b\u0924\u093e \u0939\u0948 \u091c\u093f\u0938\u0947 \u0926\u0942\u0930 \u0938\u0947 \u0938\u0915\u094d\u0930\u093f\u092f \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u093e \u0915\u094d\u0930\u092e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0924\u094d\u0930\u0941\u091f\u093f \u0939\u094b\u0924\u0940 \u0939\u0948:<\/strong> \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092e\u0947\u0902 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u092b\u094d\u092f\u0942\u091c \u0909\u0921\u093c \u091c\u093e\u0924\u093e \u0939\u0948:<\/strong> \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e \u090f\u091a\u0935\u0940 \u092b\u094d\u092f\u0942\u091c \u0915\u0947 \u0905\u0902\u0926\u0930 \u091a\u093e\u0902\u0926\u0940 \u0915\u0947 \u0924\u0924\u094d\u0935 \u0915\u094b \u092a\u093f\u0918\u0932\u093e \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915\u0930 \u092a\u093f\u0928 \u0928\u093f\u0937\u094d\u0915\u093e\u0938\u0928:<\/strong> \u091c\u092c \u092b\u094d\u092f\u0942\u091c \u092b\u091f\u0924\u093e \u0939\u0948, \u0924\u094b \u092b\u094d\u092f\u0942\u091c \u0915\u0947 \u0905\u0902\u0926\u0930 \u092e\u094c\u091c\u0942\u0926 \u090f\u0915 \u091b\u094b\u091f\u093e \u092c\u093e\u0930\u0942\u0926 \u0915\u093e \u091a\u093e\u0930\u094d\u091c \u092f\u093e \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0932\u0917\u092d\u0917 60N\u2013100N \u0915\u0940 \u0909\u091a\u094d\u091a \u092c\u0932 \u0938\u0947 \u201c\u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915\u0930 \u092a\u093f\u0928\u201d \u0915\u094b \u092b\u094d\u092f\u0942\u091c \u0915\u0948\u092a \u0938\u0947 \u092c\u093e\u0939\u0930 \u092b\u0947\u0902\u0915 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u092c\u093e\u0930:<\/strong> \u092f\u0939 \u092a\u093f\u0928 \u090f\u0932\u092c\u0940\u090f\u0938 \u0924\u0902\u0924\u094d\u0930 \u0938\u0947 \u091c\u0941\u0921\u093c\u0940 \u090f\u0915 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u092c\u093e\u0930 \u0915\u094b \u091b\u0942\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>3-\u091a\u0930 \u091f\u093f\u092a:<\/strong> \u090f\u0932\u092c\u0940\u090f\u0938 \u0916\u0941\u0932\u0924\u093e \u0939\u0948 <strong>\u0924\u0940\u0928\u094b\u0902 \u091a\u0930\u0923<\/strong> \u090f\u0915 \u0938\u093e\u0925.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092f\u0939 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0915\u094d\u092f\u094b\u0902 \u0939\u0948?<\/strong> \u0905\u0917\u0930 \u0915\u0947\u0935\u0932 \u090f\u0915 \u092b\u094d\u092f\u0942\u091c \u0909\u0921\u093c \u091c\u093e\u090f \u0914\u0930 \u0938\u094d\u0935\u093f\u091a \u092c\u0902\u0926 \u0939\u0940 \u0930\u0939\u0947, \u0924\u094b \u092e\u094b\u091f\u0930 \u092f\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0926\u094b \u092b\u0947\u091c (\u201c\u0938\u093f\u0902\u0917\u0932-\u092b\u0947\u091c\u093f\u0902\u0917\u201d) \u092a\u0930 \u091a\u0932\u0928\u0947 \u0932\u0917\u0947\u0917\u093e, \u091c\u093f\u0938\u0938\u0947 \u092f\u0939 \u0913\u0935\u0930\u0939\u0940\u091f \u0939\u094b\u0915\u0930 \u092b\u0947\u0932 \u0939\u094b \u091c\u093e\u090f\u0917\u093e\u0964 \u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915\u0930 \u0932\u093f\u0902\u0915\u091c \u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u092b\u094d\u092f\u0942\u091c \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u0938\u094d\u0935\u0930\u0942\u092a \u092a\u0942\u0930\u094d\u0923 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0939\u094b\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"8-lbs-vs-vcb-a-decision-matrix\">8. \u090f\u0932\u092c\u0940\u090f\u0938 \u092c\u0928\u093e\u092e \u0935\u0940\u0938\u0940\u092c\u0940: \u090f\u0915 \u0928\u093f\u0930\u094d\u0923\u092f \u092e\u0948\u091f\u094d\u0930\u093f\u0915\u094d\u0938<\/h2>\n\n\n\n<p>\u0915\u0947 \u0932\u093f\u090f <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker-manufacturer\/\"><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e<\/strong><\/a>, VCB \u092a\u094d\u0930\u092e\u0941\u0916 \u0909\u0924\u094d\u092a\u093e\u0926 \u0939\u0948\u0964 \u0932\u0947\u0915\u093f\u0928 \u090f\u0915 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u092f\u094b\u091c\u0928\u093e\u0915\u093e\u0930 \u0915\u0947 \u0932\u093f\u090f, \u092f\u0939 \u090f\u0915 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0909\u092a\u0915\u0930\u0923 \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th><th>\u090f\u0938\u090f\u092b6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a (\u090f\u0932\u092c\u0940\u090f\u0938)<\/th><th>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940)<\/th><\/tr><tr><td><strong>\u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f<\/strong><\/td><td>\u0932\u094b\u0921 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0914\u0930 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923<\/td><td>\u0924\u094d\u0930\u0941\u091f\u093f \u0905\u0935\u0930\u094b\u0927\u0928 \u090f\u0935\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/td><\/tr><tr><td><strong>\u0924\u094d\u0930\u0941\u091f\u093f \u0928\u093f\u0935\u093e\u0930\u0923<\/strong><\/td><td><strong>\u0928\u0939\u0940\u0902<\/strong> (HRC \u092b\u094d\u092f\u0942\u091c\u093c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0939\u0948)<\/td><td><strong>\u0939\u093e\u0901<\/strong> (40kA+ \u0924\u0915)<\/td><\/tr><tr><td><strong>\u091c\u0940\u0935\u0928 \u092c\u0926\u0932\u0928\u093e<\/strong><\/td><td>\u092e\u0927\u094d\u092f\u092e (IEC \u0935\u0930\u094d\u0917 E3, ~100 \u092a\u0942\u0930\u094d\u0923 \u092d\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928)<\/td><td>\u0909\u091a\u094d\u091a (\u0906\u0908\u0908\u0938\u0940 \u0915\u094d\u0932\u093e\u0938 E2\/C2, ~10,000 \u092a\u0942\u0930\u094d\u0923 \u0932\u094b\u0921 \u0938\u0902\u091a\u093e\u0932\u0928)<\/td><\/tr><tr><td><strong>\u091c\u091f\u093f\u0932\u0924\u093e \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong><\/td><td>\u0938\u0930\u0932 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0924\u0902\u0924\u094d\u0930)<\/td><td>\u0915\u0949\u092e\u094d\u092a\u094d\u0932\u0947\u0915\u094d\u0938 (\u0930\u093f\u0932\u0947, \u0938\u0940\u091f\u0940, \u0938\u0939\u093e\u092f\u0915 \u0936\u0915\u094d\u0924\u093f)<\/td><\/tr><tr><td><strong>\u0932\u093e\u0917\u0924 \u0906\u0927\u093e\u0930<\/strong><\/td><td>\u0928\u093f\u092e\u094d\u0928 (\u0906\u0927\u093e\u0930\u092d\u0942\u0924 \u0932\u093e\u0917\u0924)<\/td><td>\u0909\u091a\u094d\u091a (3x \u2013 4x \u090f\u0932\u092c\u0940\u090f\u0938 \u0932\u093e\u0917\u0924)<\/td><\/tr><tr><td><strong>\u0906\u092e \u092d\u0942\u092e\u093f\u0915\u093e<\/strong><\/td><td>\u0906\u0930\u090f\u092e\u092f\u0942 \u0930\u093f\u0902\u0917 \u0915\u0947\u092c\u0932, \u092e\u0948\u0928\u0941\u0905\u0932 \u0938\u0947\u0915\u094d\u0936\u0928\u0932\u093e\u0907\u091c\u093f\u0902\u0917<\/td><td>\u092e\u0941\u0916\u094d\u092f \u092b\u0940\u0921\u0930, \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u091c\u0928\u0930\u0947\u091f\u0930<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"9-strategic-applications-environmental-future\">9. \u0930\u0923\u0928\u0940\u0924\u093f\u0915 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0914\u0930 \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u092d\u0935\u093f\u0937\u094d\u092f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"current-applications\">\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923\u0940\u092f \u090a\u0930\u094d\u091c\u093e \u0938\u092e\u0942\u0939:<\/strong> \u092a\u0935\u0928 \u092b\u093e\u0930\u094d\u092e\u094b\u0902 \u092e\u0947\u0902, \u201c\u0938\u094d\u091f\u094d\u0930\u093f\u0902\u0917\u201d \u091f\u094b\u092a\u094b\u0932\u0949\u091c\u0940 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u0949\u0935\u0930 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 LBS \u0907\u0915\u093e\u0907\u092f\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u091f\u0930\u094d\u092c\u093e\u0907\u0928\u094b\u0902 \u0915\u094b \u090f\u0915 \u0921\u0947\u091c\u093c\u0940 \u091a\u0947\u0928 \u092e\u0947\u0902 \u091c\u094b\u0921\u093c\u0924\u0940 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928 (CSS):<\/strong> \u091c\u0940\u0935\u0928\u092d\u0930 \u0938\u0940\u0932\u092c\u0902\u0926 \u091f\u0948\u0902\u0915 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0928\u092e\u0940 \u0914\u0930 \u0927\u0942\u0932 \u0938\u0947 \u0905\u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0939\u0948, \u091c\u094b SF6 LBS \u0915\u094b \u092c\u093e\u0939\u0930\u0940 \u092a\u0942\u0930\u094d\u0935-\u0928\u093f\u0930\u094d\u092e\u093f\u0924 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u0928\u0915 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0932\u0942\u092a \u0938\u094d\u0935\u091a\u093e\u0932\u0928:<\/strong> RTU \u0915\u0947 \u0938\u093e\u0925 \u092f\u0941\u0917\u094d\u092e\u093f\u0924 \u092e\u094b\u091f\u0930\u093e\u0907\u091c\u094d\u0921 LBS \u0907\u0915\u093e\u0907\u092f\u093e\u0901 \u201c\u0938\u0947\u0932\u094d\u092b-\u0939\u0940\u0932\u093f\u0902\u0917 \u0917\u094d\u0930\u093f\u0921\u094d\u0938\u201d \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948\u0902, \u091c\u0939\u093e\u0901 \u0926\u094b\u0937 \u0915\u0941\u091b \u0939\u0940 \u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u0943\u0925\u0915 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-environmental-challenge-f-gas-regulations\">\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u091a\u0941\u0928\u094c\u0924\u0940 (\u090f\u092b-\u0917\u0948\u0938 \u0935\u093f\u0928\u093f\u092f\u092e\u0928)<\/h3>\n\n\n\n<p>SF6 \u090f\u0915 \u0936\u0915\u094d\u0924\u093f\u0936\u093e\u0932\u0940 \u0939\u0930\u093f\u0924\u0917\u0943\u0939 \u0917\u0948\u0938 \u0939\u0948 (GWP 23,500)\u0964 \u0928\u090f \u0928\u093f\u092f\u092e (\u091c\u0948\u0938\u0947 EU F-Gas \u0935\u093f\u0928\u093f\u092f\u092e) \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 SF6 \u0915\u0947 \u091a\u0930\u0923\u092c\u0926\u094d\u0927 \u0909\u0928\u094d\u092e\u0942\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0926\u092c\u093e\u0935 \u0921\u093e\u0932 \u0930\u0939\u0947 \u0939\u0948\u0902\u0964. <strong>\u0935\u093f\u0915\u0932\u094d\u092a:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u090f\u0932\u092c\u0940\u090f\u0938:<\/strong> \u0906\u0930\u094d\u0915 \u092c\u0941\u091d\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092c\u094b\u0924\u0932 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 (\u091c\u0948\u0938\u0947 VCB), \u0932\u0947\u0915\u093f\u0928 \u0907\u0938\u0915\u0940 \u0915\u094d\u0930\u093f\u092f\u093e\u0935\u093f\u0927\u093f \u0938\u0930\u0932 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u094d\u0935\u091a\u094d\u091b \u0939\u0935\u093e \/ \u0936\u0941\u0937\u094d\u0915 \u0939\u0935\u093e:<\/strong> \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u0926\u092c\u093e\u0935\u092f\u0941\u0915\u094d\u0924 \u0936\u0941\u0937\u094d\u0915 \u0939\u0935\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0915\u0947 \u0932\u093f\u090f \u0925\u094b\u0921\u093c\u0947 \u092c\u0921\u093c\u0947 \u091f\u0948\u0902\u0915 \u092f\u093e \u0909\u091a\u094d\u091a \u0926\u092c\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0920\u094b\u0938 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u0930\u094b\u0927\u0940:<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094b \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093c\u093f\u0928 \u092e\u0947\u0902 \u0938\u092e\u093e\u0939\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0917\u0948\u0938 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/li>\n<\/ol>\n\n\n\n<p>\u091c\u0948\u0938\u0947-\u091c\u0948\u0938\u0947 \u0909\u0926\u094d\u092f\u094b\u0917 \u092c\u0926\u0932 \u0930\u0939\u093e \u0939\u0948, \u091c\u0939\u093e\u0901 \u0938\u0902\u0915\u0941\u091a\u093f\u0924 \u0906\u0915\u093e\u0930 \u092e\u0941\u0916\u094d\u092f \u092c\u093e\u0927\u093e \u0939\u0948, \u092e\u094c\u091c\u0942\u0926\u093e \u092c\u0941\u0928\u093f\u092f\u093e\u0926\u0940 \u0922\u093e\u0902\u091a\u0947 \u0914\u0930 \u092c\u093e\u091c\u093e\u0930\u094b\u0902 \u092e\u0947\u0902 SF6 \u092a\u094d\u0930\u092d\u0941\u0924\u094d\u0935 \u092c\u0928\u093e\u090f \u0939\u0941\u090f \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"10-engineer-s-faq\">10. \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930 \u0915\u0947 \u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 1: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 \u0917\u0948\u0938 \u0915\u0947 \u0926\u092c\u093e\u0935 \u0915\u092e \u0939\u094b\u0928\u0947 \u092a\u0930 SF6 LBS \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/strong> <strong>\u0915\u0921\u093c\u093e\u0908 \u0938\u0947 \u0928\u0939\u0940\u0902\u0964.<\/strong> \u0906\u0930\u094d\u0915-\u092c\u0941\u091d\u093e\u0928\u0947 \u0915\u0940 \u0915\u094d\u0937\u092e\u0924\u093e \u0917\u0948\u0938 \u0915\u0940 \u0918\u0928\u0924\u094d\u0935 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u092f\u0926\u093f \u092e\u0948\u0928\u094b\u092e\u0940\u091f\u0930 \u0915\u092e \u0926\u092c\u093e\u0935 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0932\u093e\u0932 \u0915\u094d\u0937\u0947\u0924\u094d\u0930) \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938 \u0915\u094b \u0938\u0902\u091a\u093e\u0932\u0928 \u0930\u094b\u0915\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u091c\u092c\u0930\u0926\u0938\u094d\u0924\u0940 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0914\u0930 \u091f\u0948\u0902\u0915 \u092b\u091f\u0928\u0947 \u0915\u093e \u0916\u0924\u0930\u093e \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q2: \u092e\u0948\u0902 \u090f\u0915 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 SF6 LBS \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0948\u0938\u0947 \u0915\u0930\u0942\u0901?<\/strong> VCBs \u0915\u0947 \u0935\u093f\u092a\u0930\u0940\u0924, \u0906\u092a \u0938\u0940\u0932\u092c\u0902\u0926 \u0907\u0915\u093e\u0908 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0906\u0938\u093e\u0928\u0940 \u0938\u0947 \u0928\u0939\u0940\u0902 \u092e\u093e\u092a \u0938\u0915\u0924\u0947\u0964 \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0947\u0902 \u092e\u0941\u0916\u094d\u092f \u0930\u0942\u092a \u0938\u0947 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0917\u0948\u0938 \u0926\u092c\u093e\u0935 \u091c\u093e\u0901\u091a:<\/strong> \u092e\u0948\u0928\u094b\u092e\u0940\u091f\u0930 \u0915\u093e \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u0921\u0915\u094d\u091f\u094b\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923):<\/strong> \u092c\u0941\u0936\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u092a\u093e\u0930 \u092e\u093e\u092a\u0947\u0902 (\u0906\u092e \u092e\u093e\u0928 &lt; 50 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e)\u0964.<\/li>\n\n\n\n<li><strong>\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 (\u092a\u0940\u0921\u0940):<\/strong> \u091f\u0948\u0902\u0915 \u0916\u094b\u0932\u0947 \u092c\u093f\u0928\u093e \u0906\u0902\u0924\u0930\u093f\u0915 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u0948\u0902\u0921\u0939\u0947\u0932\u094d\u0921 TEV\/\u0905\u0932\u094d\u091f\u094d\u0930\u093e\u0938\u094b\u0928\u093f\u0915 \u0938\u0947\u0902\u0938\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 3: \u0915\u094d\u092f\u093e \u090f\u0915 \u090f\u0932\u092c\u0940\u090f\u0938 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0915\u0940 \u0927\u093e\u0930\u093e \u0915\u094b \u0924\u094b\u0921\u093c \u0938\u0915\u0924\u093e \u0939\u0948?<\/strong> \u092e\u093e\u0928\u0915 \u090f\u0932\u092c\u0940\u090f\u0938 \u0907\u0915\u093e\u0907\u092f\u093e\u0901 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u093f\u0935 \u0927\u093e\u0930\u093e\u0913\u0902 (\u0932\u093e\u0907\u0928\u094b\u0902 \u092f\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915\u094b\u0902) \u0915\u0947 \u0938\u093e\u0925 \u092a\u0941\u0928\u0903 \u0938\u094d\u091f\u094d\u0930\u093e\u0907\u0915 \u091c\u094b\u0916\u093f\u092e\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0902\u0918\u0930\u094d\u0937 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964 \u0906\u092a\u0915\u094b \u090f\u0915 \u0910\u0938\u0947 \u0938\u094d\u0935\u093f\u091a \u0915\u093e \u0909\u0932\u094d\u0932\u0947\u0916 \u0915\u0930\u0928\u093e \u0939\u094b\u0917\u093e \u091c\u094b \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u094b <strong>\u0906\u0908\u0908\u0938\u0940 62271-103 \u0915\u094d\u0932\u093e\u0938 C1 \u092f\u093e C2<\/strong> \u092f\u0926\u093f \u0906\u092a \u0905\u0915\u094d\u0938\u0930 \u092c\u093f\u0928\u093e \u0932\u094b\u0921 \u0935\u093e\u0932\u0940 \u0915\u0947\u092c\u0932 \u092f\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u092c\u0926\u0932\u0928\u0947 \u0915\u093e \u0907\u0930\u093e\u0926\u093e \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"11-conclusion-specifying-for-the-right-application\">11. \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937: \u0938\u0939\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928<\/h2>\n\n\n\n<p>\u0926 <strong>\u090f\u0938\u090f\u092b6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a<\/strong> \u092f\u0939 \u092e\u093e\u0927\u094d\u092f\u092e\u093f\u0915 \u0935\u093f\u0924\u0930\u0923 \u0915\u0940 \u0930\u0940\u0922\u093c \u092c\u0928\u093e \u0939\u0941\u0906 \u0939\u0948, \u0928 \u0915\u093f \u0907\u0938\u0932\u093f\u090f \u0915\u093f \u092f\u0939 \u0938\u092c\u0938\u0947 \u0936\u0915\u094d\u0924\u093f\u0936\u093e\u0932\u0940 \u0909\u092a\u0915\u0930\u0923 \u0939\u0948, \u092c\u0932\u094d\u0915\u093f \u0907\u0938\u0932\u093f\u090f \u0915\u093f \u092f\u0939 \u0938\u092c\u0938\u0947 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u0948\u0964 \u092f\u0939 \u0917\u094d\u0930\u093f\u0921 \u092e\u0947\u0902 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0928\u094b\u0921\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093e, \u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f\u0928\u0947\u0938 \u0914\u0930 \u0932\u093e\u0917\u0924 \u0915\u093e \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0938\u0902\u0924\u0941\u0932\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u092b\u0932 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u092d\u093e\u0930\u0940 \u0938\u0902\u092a\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f VCBs \u0914\u0930 \u092a\u094d\u0930\u0935\u093e\u0939 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0915\u0947 \u0932\u093f\u090f LBS \u0907\u0915\u093e\u0907\u092f\u094b\u0902 \u0915\u0947 \u0909\u092a\u092f\u094b\u0917 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0928 \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u092d\u094d\u0930\u092e\u093f\u0924 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092c\u091c\u091f \u092b\u0942\u0932\u093e-\u092b\u0942\u0932\u093e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 \u092f\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0947 \u0938\u092e\u091d\u094c\u0924\u093e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<div class=\"xbrele-classic-card\">\n    <div class=\"card-inner\">\n        <div class=\"card-thumb\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/download-icon.webp\" alt=\"SF6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a \u0924\u0915\u0928\u0940\u0915\u0940 \u092a\u0940\u0921\u0940\u090f\u092b\">\n        <\/div>\n        \n        <div class=\"card-details\">\n            <span class=\"card-label\">\u0905\u092d\u093f\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940 \u0936\u094d\u0935\u0947\u0924\u092a\u0924\u094d\u0930<\/span>\n            <h3>SF6 \u0932\u094b\u0921 \u092c\u094d\u0930\u0947\u0915 \u0938\u094d\u0935\u093f\u091a: \u0915\u093e\u0930\u094d\u092f \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0914\u0930 LBS \u092c\u0928\u093e\u092e VCB \u0917\u093e\u0907\u0921<\/h3>\n            <p>\u090f\u0915 \u0917\u0939\u0928 \u0924\u0915\u0928\u0940\u0915\u0940 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e \u091c\u094b SF6 \u0917\u0948\u0938 \u0915\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0917\u0941\u0923\u094b\u0902, \u0906\u0930\u094d\u0915 \u092c\u0941\u091d\u093e\u0928\u0947 \u0915\u0940 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0914\u0930 \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u0947 \u0932\u093f\u090f LBS \u0914\u0930 VCB \u0915\u0940 \u090f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0924\u0941\u0932\u0928\u093e \u0915\u093e \u0905\u0928\u094d\u0935\u0947\u0937\u0923 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n            \n            <div class=\"card-meta\">\n                <span><i class=\"far fa-file-pdf\"><\/i> \u0938\u094d\u0935\u0930\u0942\u092a: \u092a\u0940\u0921\u0940\u090f\u092b \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c<\/span>\n                <span><i class=\"far fa-user\"><\/i> \u0932\u0947\u0916\u093f\u0915\u093e: \u0939\u0928\u094d\u0928\u093e \u091d\u0942<\/span>\n            <\/div>\n            \n            <a href=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele.com-What-Is-an-SF6-Load-Break-Switch-Working-Principle-LBS-vs-VCB-Guide.pdf\" class=\"card-download-btn\" target=\"_blank\" rel=\"noopener\">\n                <i class=\"fas fa-file-download\"><\/i> SF6 LBS \u0917\u093e\u0907\u0921 \u0921\u093e\u0909\u0928\u0932\u094b\u0921 \u0915\u0930\u0947\u0902\n            <\/a>\n        <\/div>\n    <\/div>\n<\/div>\n\n<style>\n\/* XBRELE \u7ecf\u5178\u5de5\u4e1a\u98ce\u683c - \u54c1\u724c\u8272 #0fb4ad *\/\n.xbrele-classic-card {\n    background: #fdfdfd;\n    border: 1px solid #e1e4e8;\n    border-left: 6px solid #0fb4ad; \/* \u54c1\u724c\u9752\u7eff\u8272\u4fa7\u8fb9\u6761 *\/\n    padding: 28px;\n    margin: 35px 0;\n    border-radius: 4px;\n    box-shadow: 0 2px 12px rgba(0,0,0,0.04);\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n}\n\n.card-inner {\n    display: flex;\n    gap: 30px;\n    align-items: center;\n}\n\n.card-thumb img {\n    width: 130px; \n    height: auto;\n    border-radius: 2px;\n}\n\n.card-label {\n    color: #0fb4ad;\n    font-size: 12px;\n    text-transform: uppercase;\n    font-weight: 800;\n    letter-spacing: 1.2px;\n    margin-bottom: 6px;\n    display: block;\n}\n\n.card-details h3 {\n    margin: 5px 0 10px 0;\n    font-size: 22px;\n    color: #1a1a1a;\n    line-height: 1.3;\n}\n\n.card-details p {\n    font-size: 14.5px;\n    color: #586069;\n    margin-bottom: 18px;\n    line-height: 1.5;\n}\n\n.card-meta {\n    font-size: 13px;\n    color: #959da5;\n    margin-bottom: 22px;\n    display: flex;\n    gap: 20px;\n}\n\n.card-meta i {\n    color: #0fb4ad;\n    margin-right: 5px;\n}\n\n.card-download-btn {\n    display: inline-flex;\n    align-items: center;\n    gap: 10px;\n    background-color: #0fb4ad;\n    color: #ffffff !important;\n    padding: 12px 28px;\n    border-radius: 3px;\n    text-decoration: none !important;\n    font-weight: 700;\n    font-size: 15px;\n    transition: all 0.25s ease;\n    box-shadow: 0 4px 10px rgba(15, 180, 173, 0.2);\n}\n\n.card-download-btn:hover {\n    background-color: #0d9b94;\n    box-shadow: 0 6px 15px rgba(15, 180, 173, 0.3);\n    transform: translateY(-1px);\n}\n\n\/* \u54cd\u5e94\u5f0f\u9002\u914d\u79fb\u52a8\u7aef *\/\n@media (max-width: 650px) {\n    .card-inner { flex-direction: column; text-align: center; }\n    .card-thumb img { width: 100px; }\n    .card-meta { justify-content: center; }\n}\n<\/style>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u092a\u0920\u0928 \u0914\u0930 \u091a\u092f\u0928 \u0938\u0902\u0938\u093e\u0927\u0928<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/hi\/products\/\">\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u0924\u094d\u092a\u093e\u0926 \u0905\u0935\u0932\u094b\u0915\u0928<\/a> \u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u091c\u093e\u0901\u091a\u0947\u0902, \u0938\u0940\u092e\u093e\u090f\u0901, \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0928\u094b\u091f\u094d\u0938<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Engineering Key Takeaways \ud83d\udd39 LBS vs. VCB Distinction: An LBS is designed for load management (switching nominal currents), whereas a VCB is a protection device for interrupting massive fault currents. \ud83d\udd39 The 3-Position Safety Logic: Modern RMUs use a mechanically interlocked sequence (ON \u2192 OFF \u2192 EARTH) to physically prevent human errors, such as earthing [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2129,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27,24],"tags":[],"class_list":["post-2126","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2126"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2126\/revisions"}],"predecessor-version":[{"id":3649,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2126\/revisions\/3649"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2129"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2126"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}