{"id":2137,"date":"2025-12-17T14:05:45","date_gmt":"2025-12-17T14:05:45","guid":{"rendered":"https:\/\/xbrele.com\/?p=2137"},"modified":"2026-04-07T14:58:39","modified_gmt":"2026-04-07T14:58:39","slug":"what-is-a-vacuum-interrupter","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/what-is-a-vacuum-interrupter\/","title":{"rendered":"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 (VI) \u0915\u094d\u092f\u093e \u0939\u0948 \u0914\u0930 \u092f\u0939 \u0915\u0948\u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948?"},"content":{"rendered":"<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094d\u092f\u093e \u0939\u0948? (\u0915\u093e\u0930\u094d\u092f \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0914\u0930 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0917\u093e\u0907\u0921)\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/DjTiW8pCliw?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"background-color: #f5f7f7; border-left: 5px solid #15b3ab; padding: 25px; margin-bottom: 30px; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\">\n    <h2 style=\"color: #333; margin-top: 0; font-size: 1.4rem; font-weight: 700; border-bottom: 1px solid #e0e0e0; padding-bottom: 12px; margin-bottom: 15px;\">\u0915\u093e\u0930\u094d\u092f\u0915\u093e\u0930\u0940 \u0938\u093e\u0930\u093e\u0902\u0936: \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0924\u094d\u0935\u0930\u093f\u0924 \u0905\u0935\u0932\u094b\u0915\u0928<\/h2>\n    \n    <p style=\"font-size: 1rem; line-height: 1.6; color: #444; margin-bottom: 15px;\">\n        <strong>\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u093e \u201c\u0926\u093f\u0932\u201d:<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 (VI) \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0935\u0940\u0915\u0943\u0924 \u092e\u093e\u0928\u0915 \u0939\u0948, \u091c\u094b \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 <strong>\u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f<\/strong> \u090f\u0915 \u0909\u091a\u094d\u091a-\u0936\u0942\u0928\u094d\u092f \u0915\u0915\u094d\u0937 \u092e\u0947\u0902 (&lt; 10\u207b\u2075 Pa) \u0935\u093f\u0936\u093e\u0932 \u092b\u0949\u0932\u094d\u091f \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f\u0964.\n    <\/p>\n    \n    <ul style=\"font-size: 1rem; line-height: 1.6; color: #444; margin-bottom: 20px;\">\n        <li style=\"margin-bottom: 8px;\"><strong>\u092e\u0941\u0916\u094d\u092f \u092a\u094d\u0930\u094c\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u0940:<\/strong> \u0909\u092a\u092f\u094b\u0917 <strong>\u0924\u093e\u0902\u092c\u093e-\u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e<\/strong> \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0914\u0930 \u0924\u0940\u0935\u094d\u0930 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0930\u093f\u0915\u0935\u0930\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u092a\u0930\u094d\u0915 (\u092a\u093e\u0936\u0947\u0928 \u0915\u093e \u0928\u093f\u092f\u092e)\u0964.<\/li>\n        <li style=\"margin-bottom: 8px;\"><strong>\u0906\u0930\u094d\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923:<\/strong> <strong>\u090f\u090f\u092e\u090f\u092b<\/strong> (\u0905\u0915\u094d\u0937\u0940\u092f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930) \u091c\u094d\u092f\u093e\u092e\u093f\u0924\u093f \u0909\u091a\u094d\u091a-\u0927\u093e\u0930\u093e \u0926\u094b\u0937\u094b\u0902 (&gt;40kA) \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948, \u091c\u092c\u0915\u093f <strong>\u0906\u0930\u090f\u092e\u090f\u092b<\/strong> (\u0930\u0947\u0921\u093f\u092f\u0932) \u0935\u093f\u0924\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u0928\u0915 \u0939\u0948\u0964.<\/li>\n        <li style=\"margin-bottom: 8px;\"><strong>\u0928\u093f\u0930\u094d\u092e\u093e\u0923:<\/strong> \u092e\u093e\u0930\u094d\u0917 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0939\u0930\u094d\u092e\u0947\u099f\u09bf\u0995 \u0938\u0940\u0932\u093f\u0902\u0917 <strong>\u090f\u0915-\u092c\u093e\u0930 \u0915\u093e \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917<\/strong> 20-30 \u0935\u0930\u094d\u0937 \u0915\u0940 \u0930\u0916\u0930\u0916\u093e\u0935-\u092e\u0941\u0915\u094d\u0924 \u0938\u0947\u0935\u093e \u0905\u0935\u0927\u093f \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 (\u090f\u0915 \u092c\u093e\u0930 \u0932\u0917\u093e\u090f\u0902 \u0914\u0930 \u092d\u0942\u0932 \u091c\u093e\u090f\u0902)\u0964.<\/li>\n    <\/ul>\n\n    <div style=\"background-color: rgba(21, 179, 171, 0.08); padding: 12px 15px; border-radius: 2px; border: 1px solid rgba(21, 179, 171, 0.2);\">\n        <p style=\"margin: 0; font-size: 0.95rem; color: #222;\">\n            <strong>\u091a\u092f\u0928 \u0928\u093f\u0930\u094d\u0923\u092f:<\/strong> IEC-\u0905\u0928\u0941\u092a\u093e\u0932\u0915 \u0938\u094d\u0925\u093e\u092f\u093f\u0924\u094d\u0935 (\u0915\u094d\u0932\u093e\u0938 E2\/M2) \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0935\u093e\u0932\u0947 OEMs \u0915\u0947 \u0932\u093f\u090f, <strong style=\"color: #15b3ab;\">\u090f\u0915\u094d\u0938\u092c\u0940\u0906\u0930\u0908\u090f\u0932\u0908<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 SF6 \u0915\u093e \u090f\u0915 \u0936\u094d\u0930\u0947\u0937\u094d\u0920, \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923-\u0905\u0928\u0941\u0915\u0942\u0932 \u0935\u093f\u0915\u0932\u094d\u092a \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b 12kV\u201340.5kV \u0917\u094d\u0930\u093f\u0921\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092b\u0948\u0915\u094d\u091f\u094d\u0930\u0940-\u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0938\u091f\u0940\u0915\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.\n        <\/p>\n    <\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"introduction-the-heart-of-medium-voltage-switching\">\u092a\u0930\u093f\u091a\u092f: \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u093e \u201c\u0939\u0943\u0926\u092f\u201d<\/h2>\n\n\n\n<p>\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c (MV) \u0914\u0930 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c (HV) \u092c\u093f\u091c\u0932\u0940 \u0935\u093f\u0924\u0930\u0923 \u0915\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0905\u0935\u0938\u0902\u0930\u091a\u0928\u093e \u092e\u0947\u0902, \u092a\u0942\u0930\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0905\u0915\u094d\u0938\u0930 \u090f\u0915 \u0939\u0940 \u0918\u091f\u0915 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948: \u0938\u094d\u0935\u093f\u091a\u0964 \u091c\u092c\u0915\u093f \u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0906\u0935\u0936\u094d\u092f\u0915 \u0917\u0924\u093f\u091c \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0930\u093f\u0932\u0947 \u0932\u0949\u091c\u093f\u0915 \u092e\u0938\u094d\u0924\u093f\u0937\u094d\u0915 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u093e \u0939\u0948, \u0935\u093f\u0936\u093e\u0932 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0928\u0947 \u0915\u093e \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092d\u094c\u0924\u093f\u0915 \u0915\u093e\u0930\u094d\u092f \u090f\u0915 \u0939\u0930\u094d\u092e\u0947\u091f\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u0940\u0932\u092c\u0902\u0926 \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u0915\u0915\u094d\u0937 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0939\u094b\u0924\u093e \u0939\u0948\u2014 <strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 (VI)<\/strong>.<\/p>\n\n\n\n<p>\u0905\u0915\u094d\u0938\u0930 \u090f\u0915 \u0915\u0947 \u201c\u0926\u093f\u0932\u201d \u092f\u093e \u201c\u092c\u094b\u0924\u0932\u201d \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0938\u0902\u0926\u0930\u094d\u092d\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/a>, VI \u090f\u0915 \u0905\u092d\u093f\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940 \u091a\u092e\u0924\u094d\u0915\u093e\u0930 \u0939\u0948\u0964 \u092f\u0939 630A \u0915\u0947 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0932\u094b\u0921 \u0927\u093e\u0930\u093e\u0913\u0902 \u0938\u0947 \u0932\u0947\u0915\u0930 63 kA \u0938\u0947 \u0905\u0927\u093f\u0915 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0924\u0915 \u0915\u0940 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u091a\u093e\u0932\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-vacuum-vacuum-vs-sf6-vs-oil\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u092f\u094b\u0902? (\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092c\u0928\u093e\u092e SF6 \u092c\u0928\u093e\u092e \u0924\u0947\u0932)<\/h3>\n\n\n\n<p>\u0924\u0947\u0932 \u091c\u0948\u0938\u0940 \u092a\u0941\u0930\u093e\u0928\u0940 \u0924\u0915\u0928\u0940\u0915\u094b\u0902 \u0915\u0947 \u0935\u093f\u092a\u0930\u0940\u0924 \u092f\u093e <a href=\"https:\/\/xbrele.com\/hi\/sf6-load-break-switch-working-principle\/\">\u090f\u0938\u090f\u092b6 (\u0938\u0932\u094d\u092b\u0930 \u0939\u0947\u0915\u094d\u0938\u093e\u092b\u094d\u0932\u094b\u0930\u093e\u0907\u0921)<\/a>, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0924\u0915\u0928\u0940\u0915 12kV\u201340.5kV \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u092e\u0941\u0916 \u092e\u093e\u0928\u0915 \u092c\u0928 \u0917\u0908 \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0938\u094d\u0925\u093f\u0930\u0924\u093e:<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0936\u0942\u0928\u094d\u092f \u0917\u094d\u0930\u0940\u0928\u0939\u093e\u0909\u0938 \u0917\u0948\u0938 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u091c\u0948\u0938\u0947-\u091c\u0948\u0938\u0947 \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u0928\u093f\u092f\u092e (\u091c\u0948\u0938\u0947 \u092f\u0942\u0930\u094b\u092a\u0940\u092f \u0938\u0902\u0918 \u0915\u093e \u090f\u092b-\u0917\u0948\u0938 \u0928\u093f\u092f\u092e) SF6 \u0915\u094b \u091a\u0930\u0923\u092c\u0926\u094d\u0927 \u0930\u0942\u092a \u0938\u0947 \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930 \u0930\u0939\u0947 \u0939\u0948\u0902, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915\u092e\u093e\u0924\u094d\u0930 \u092d\u0935\u093f\u0937\u094d\u092f-\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0935\u093f\u0915\u0932\u094d\u092a \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0930\u0916\u0930\u0916\u093e\u0935:<\/strong> \u201c\u092b\u093f\u091f \u090f\u0902\u0921 \u092b\u0949\u0930\u0917\u0947\u091f\u201d \u0924\u0915\u0928\u0940\u0915 \u0915\u0947 \u0928\u093e\u092e \u0938\u0947 \u091c\u093e\u0928\u0940 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0940 \u090f\u0915 \u0938\u0940\u0932\u092c\u0902\u0926 VI \u0915\u094b \u0907\u0938\u0915\u0940 20\u201330 \u0935\u0930\u094d\u0937 \u0915\u0940 \u0938\u0947\u0935\u093e \u0905\u0935\u0927\u093f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0917\u0948\u0938 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u092f\u093e \u092a\u0941\u0928\u0903\u092d\u0930\u093e\u0908 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u094d\u0925\u093f\u0930\u0924\u093e:<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0917\u0948\u0938-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u093e\u092b\u0940 \u0905\u0927\u093f\u0915 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0925\u093e\u092f\u093f\u0924\u094d\u0935 (30,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915) \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n<\/ul>\n\n\n\n<p>OEM \u0916\u0930\u0940\u0926\u093e\u0930\u094b\u0902 \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0921\u093f\u091c\u093e\u0907\u0928\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, VIs \u0915\u0940 \u0938\u0924\u0939\u0940 \u0938\u092e\u091d \u0905\u092c \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0928\u0939\u0940\u0902 \u0930\u0939\u0940\u0964 \u090f\u0915 \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e VI \u0914\u0930 \u090f\u0915 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0935\u093f\u0935\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u0939\u093f\u0924 \u0939\u0948: \u0924\u093e\u0902\u092c\u0947 \u092e\u0947\u0902 \u0917\u0948\u0938 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e, \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u0940 \u091c\u094d\u092f\u093e\u092e\u093f\u0924\u093f, \u0914\u0930 \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e\u0964 \u092f\u0939 \u0932\u0947\u0916 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0906\u092a\u0915\u0940 \u0938\u0939\u093e\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u092a\u094d\u0930\u093e\u092e\u093e\u0923\u093f\u0915 \u0938\u094d\u0924\u0930 \u0915\u093e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-vacuum-interrupter\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094d\u092f\u093e \u0939\u0948?<\/h2>\n\n\n\n<p>\u0924\u0915\u0928\u0940\u0915\u0940 \u0930\u0942\u092a \u0938\u0947 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924, \u090f\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u090f\u0915 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-component-manufacturer\/\">\u0935\u093f\u0936\u0947\u0937\u0940\u0915\u0943\u0924 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915<\/a> \u091c\u094b \u0909\u091a\u094d\u091a-\u0936\u0942\u0928\u094d\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 <strong>10\u207b\u2075 \u092a\u093e\u0938\u094d\u0915\u0932<\/strong> \u092f\u093e \u092c\u0947\u0939\u0924\u0930) \u0906\u0930\u094d\u0915 \u092c\u0941\u091d\u093e\u0928\u0947 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u093e\u0927\u094d\u092f\u092e \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0915\u094d\u092f\u094b\u0902\u0915\u093f \u090f\u0915 \u201c\u092a\u0930\u093f\u092a\u0942\u0930\u094d\u0923\u201d \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u092e\u0947\u0902 \u0915\u094b\u0908 \u0906\u092f\u0928\u0940\u0915\u0930\u0923 \u092f\u094b\u0917\u094d\u092f \u0917\u0948\u0938 \u0905\u0923\u0941 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0947, \u0907\u0938\u0932\u093f\u090f \u0924\u0941\u0932\u0928\u0940\u092f \u0917\u0948\u092a\u094b\u0902 \u092a\u0930 \u0907\u0938\u0915\u0940 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0939\u0935\u093e \u092f\u093e SF6 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u093e\u092b\u0940 \u0905\u0927\u093f\u0915 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0948\u092a \u0905\u0938\u093e\u0927\u093e\u0930\u0923 \u0930\u0942\u092a \u0938\u0947 \u091b\u094b\u091f\u093e \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u2014\u0905\u0915\u094d\u0938\u0930 \u0915\u0947\u0935\u0932 <strong>6 \u092e\u093f\u092e\u0940 \u0938\u0947 20 \u092e\u093f\u092e\u0940<\/strong>\u2014\u091c\u093f\u0938\u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e\u0938\u094d\u0935\u0930\u0942\u092a \u090f\u0915 \u0938\u0902\u0915\u0941\u091a\u093f\u0924, \u0915\u092e-\u090a\u0930\u094d\u091c\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u092c\u0928\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"typical-technical-parameters\">\u0906\u092e \u0924\u0915\u0928\u0940\u0915\u0940 \u092e\u093e\u092a\u0926\u0902\u0921<\/h3>\n\n\n\n<p>\u0924\u094d\u0935\u0930\u093f\u0924 \u0938\u0902\u0926\u0930\u094d\u092d \u0915\u0947 \u0932\u093f\u090f, \u092f\u0939\u093e\u0901 \u0935\u0947 \u092e\u093e\u0928\u0915 \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930 \u0926\u093f\u090f \u0917\u090f \u0939\u0948\u0902 \u091c\u093f\u0928\u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th><th>\u0906\u092e \u092e\u093e\u0928 \/ \u0935\u093f\u0936\u0947\u0937\u0924\u093e<\/th><\/tr><tr><td><strong>\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/strong><\/td><td>1.14 kV \u0938\u0947 40.5 kV (\u090f\u0915\u0932 \u092c\u094d\u0930\u0947\u0915 \u0915\u0947 \u0932\u093f\u090f 72.5 kV \u0924\u0915)<\/td><\/tr><tr><td><strong>\u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u093f\u0924 \u0927\u093e\u0930\u093e<\/strong><\/td><td>630 A \u0938\u0947 5000 A \u0924\u0915<\/td><\/tr><tr><td><strong>\u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u093f\u0902\u0917 \u0915\u0930\u0902\u091f<\/strong><\/td><td>16 kA \u0938\u0947 63 kA (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 80 kA \u0924\u0915)<\/td><\/tr><tr><td><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0948\u092a<\/strong><\/td><td>6 \u092e\u093f\u092e\u0940 (12kV) \u0938\u0947 20 \u092e\u093f\u092e\u0940 (40.5kV)<\/td><\/tr><tr><td><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091c\u0940\u0935\u0928<\/strong><\/td><td>10,000 \u0938\u0947 30,000 \u0938\u0902\u091a\u093e\u0932\u0928 (\u0915\u094d\u0932\u093e\u0938 M2)<\/td><\/tr><tr><td><strong>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091c\u0940\u0935\u0928 (\u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f)<\/strong><\/td><td>30 \u0938\u0947 100 \u0938\u0902\u091a\u093e\u0932\u0928 (\u0915\u094d\u0932\u093e\u0938 E2)<\/td><\/tr><tr><td><strong>\u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u092c\u093e\u0935<\/strong><\/td><td>&lt; 1.33 \u00d7 10\u207b\u00b3 \u092a\u093e\u0938\u094d\u0915\u0932 (\u0936\u0947\u0932\u094d\u092b \u091c\u0940\u0935\u0928 \u0915\u0947 \u0905\u0902\u0924 \u092e\u0947\u0902)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-physics-of-insulation-paschen-s-law\">\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u092d\u094c\u0924\u093f\u0915\u0940: \u092a\u093e\u0936\u0947\u0928 \u0915\u093e \u0928\u093f\u092f\u092e<\/h3>\n\n\n\n<p>\u0938\u092e\u091d\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f <em>\u0915\u094d\u092f\u094b\u0902<\/em> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0924\u0928\u093e \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0939\u0948 \u0915\u093f \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930 \u0907\u0938\u0947 <a href=\"https:\/\/en.wikipedia.org\/wiki\/Paschen%27s_law\" target=\"_blank\" rel=\"noopener\"><strong>\u092a\u093e\u0936\u0947\u0928 \u0915\u093e \u0928\u093f\u092f\u092e<\/strong><\/a>. \u0915\u093e\u0928\u0942\u0928 \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u0926\u092c\u093e\u0935 \u0915\u0947 \u092b\u0932\u0928 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0935\u0930\u094d\u0923\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 (<em>p<\/em>) \u0914\u0930 \u0917\u0948\u092a \u0926\u0942\u0930\u0940 (<em>d<\/em>).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0932\u093e\u092d:<\/strong> \u0909\u091a\u094d\u091a \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 (\u092a\u093e\u0936\u0947\u0928 \u0935\u0915\u094d\u0930 \u0915\u0947 \u092c\u093e\u0908\u0902 \u0913\u0930) \u092e\u0947\u0902 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928 \u0915\u093e \u0914\u0938\u0924 \u092e\u0941\u0915\u094d\u0924 \u092a\u0925 \u0905\u0924\u094d\u092f\u0902\u0924 \u0932\u0902\u092c\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0926\u094d\u0935\u093e\u0930\u093e \u0924\u094d\u0935\u093e\u0930\u093f\u0924 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928 \u0915\u093e \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u0917\u0948\u0938 \u0905\u0923\u0941 \u0938\u0947 \u091f\u0915\u0930\u093e\u0915\u0930 \u0906\u092f\u0928\u0940\u0915\u0930\u0923 \u0939\u093f\u092e\u0938\u094d\u0916\u0932\u0928 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0938\u0902\u092d\u093e\u0935\u0928\u093e \u092c\u0939\u0941\u0924 \u0915\u092e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0906\u0932\u094b\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0938\u0940\u092e\u093e:<\/strong> \u092f\u0939 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0936\u0915\u094d\u0924\u093f \u0924\u092c \u0924\u0915 \u092c\u0928\u0940 \u0930\u0939\u0924\u0940 \u0939\u0948 \u091c\u092c \u0924\u0915 \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u092c\u093e\u0935 \u0928\u0940\u091a\u0947 \u092c\u0928\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964 <strong>10\u207b\u00b2 \u092a\u093e\u0938\u094d\u0915\u0932<\/strong>. \u092f\u0926\u093f \u0926\u092c\u093e\u0935 \u092c\u0922\u093c\u0924\u093e \u0939\u0948 (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0930\u093f\u0938\u093e\u0935 \u0915\u0947 \u0915\u093e\u0930\u0923), \u0924\u094b \u0938\u093f\u0938\u094d\u091f\u092e \u0935\u0915\u094d\u0930 \u092a\u0930 \u090a\u092a\u0930 \u0915\u0940 \u0913\u0930 \u092c\u0922\u093c\u0924\u093e \u0939\u0948, \u0914\u0930 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0936\u0915\u094d\u0924\u093f \u0927\u094d\u0935\u0938\u094d\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"internal-structure-anatomy-of-a-vacuum-interrupter\">\u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e: \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0940 \u0930\u091a\u0928\u093e<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram.webp\" alt=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u093e \u0932\u0902\u092c\u0935\u0924 \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928 \u0906\u0930\u0947\u0916, \u091c\u093f\u0938\u092e\u0947\u0902 \u0938\u0902\u092a\u0930\u094d\u0915, \u092c\u0947\u0932\u094b \u0914\u0930 \u0922\u093e\u0932\u0947\u0902 \u0926\u093f\u0916\u093e\u090f \u0917\u090f \u0939\u0948\u0902\u0964.\" class=\"wp-image-2141\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0909\u091a\u094d\u091a-\u0936\u0941\u0926\u094d\u0927\u0924\u093e \u0935\u093e\u0932\u0940 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u093e \u090f\u0915 \u091c\u091f\u093f\u0932 \u0938\u0902\u092f\u094b\u091c\u0928 \u0939\u0948, \u091c\u093f\u0938\u0947 \u0909\u0928\u094d\u0928\u0924 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092b\u0930\u094d\u0928\u0947\u0938 \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917 \u0926\u094d\u0935\u093e\u0930\u093e \u091c\u094b\u0921\u093c\u093e \u0917\u092f\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-the-contacts-metallurgy-and-manufacturing\">1. \u0938\u0902\u092a\u0930\u094d\u0915: \u0927\u093e\u0924\u0941 \u0935\u093f\u091c\u094d\u091e\u093e\u0928 \u0914\u0930 \u0935\u093f\u0928\u093f\u0930\u094d\u092e\u093e\u0923<\/h3>\n\n\n\n<p>\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u092c\u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0918\u091f\u0915 \u0939\u0948\u0902\u0964 \u0907\u0928\u094d\u0939\u0947\u0902 \u0917\u0930\u094d\u092e\u0940 \u0915\u094b \u0915\u0941\u0936\u0932\u0924\u093e\u092a\u0942\u0930\u094d\u0935\u0915 \u0938\u0902\u091a\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0906\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0914\u0930 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u093e\u092e\u0917\u094d\u0930\u0940 (CuCr \u092e\u093f\u0936\u094d\u0930\u0927\u093e\u0924\u0941\u090f\u0901):<\/strong> \u0906\u0927\u0941\u0928\u093f\u0915 \u0935\u0940\u0906\u0908\u090f\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 <strong>\u0924\u093e\u0902\u092c\u093e-\u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e (CuCr)<\/strong>, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 CuCr50 (50\/50 \u0905\u0928\u0941\u092a\u093e\u0924)\u0964 \u0924\u093e\u0902\u092c\u093e \u091a\u093e\u0932\u0915\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948; \u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e \u0909\u091a\u094d\u091a \u0917\u0932\u0928\u093e\u0902\u0915 \u0914\u0930 \u201c\u0917\u0947\u091f\u0930\u093f\u0902\u0917\u201d \u0917\u0941\u0923 (\u0936\u0947\u0937 \u0917\u0948\u0938\u094b\u0902 \u0915\u094b \u0930\u093e\u0938\u093e\u092f\u0928\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0905\u0935\u0936\u094b\u0937\u093f\u0924 \u0915\u0930\u0928\u093e) \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u093f\u0902\u091f\u0930\u093f\u0902\u0917 \u092c\u0928\u093e\u092e \u0907\u0928\u094d\u092b\u093f\u0932\u094d\u091f\u094d\u0930\u0947\u0936\u0928:<\/strong>\n<ul class=\"wp-block-list\">\n<li><em>\u0938\u093f\u0902\u091f\u0930\u093f\u0902\u0917 (\u0920\u094b\u0938 \u0905\u0935\u0938\u094d\u0925\u093e):<\/em> \u090f\u0915 \u092e\u0939\u0940\u0928, \u0938\u092e\u093e\u0928 \u0938\u0942\u0915\u094d\u0937\u094d\u092e\u0938\u0902\u0930\u091a\u0928\u093e \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0914\u0930 \u0915\u092e \u091a\u0949\u092a\u093f\u0902\u0917 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e\u0964 \u092f\u0939 \u0906\u0927\u0941\u0928\u093f\u0915 \u092e\u0927\u094d\u092f\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u093e \u092e\u093e\u0928\u0915 \u0939\u0948\u0964.<\/li>\n\n\n\n<li><em>\u0918\u0941\u0938\u092a\u0948\u0920:<\/em> \u092a\u093f\u0918\u0932\u093e \u0939\u0941\u0906 \u0924\u093e\u0902\u092c\u093e \u0938\u093f\u0902\u091f\u0930 \u0915\u093f\u090f \u0917\u090f \u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e \u0915\u0902\u0915\u093e\u0932 \u092e\u0947\u0902 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0930 \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0905\u0924\u094d\u092f\u0902\u0924 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092e\u091c\u092c\u0942\u0924, \u0905\u0915\u094d\u0938\u0930 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 <a href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/\">\u092d\u093e\u0930\u0940-\u092d\u0930\u0915\u092e \u0938\u0902\u092a\u0930\u094d\u0915\u093f\u0924\u094d\u0930<\/a> \u092f\u093e \u0928\u093f\u092e\u094d\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f\u0964.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0917\u0948\u0938 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e:<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u092e\u0947\u0902 \u0911\u0915\u094d\u0938\u0940\u091c\u0928 \u0914\u0930 \u0928\u093e\u0907\u091f\u094d\u0930\u094b\u091c\u0928 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u0915\u094b \u0938\u0916\u094d\u0924\u0940 \u0938\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f (\u0905\u0915\u094d\u0938\u0930 &lt; 10 ppm)\u0964 \u092f\u0926\u093f \u0927\u093e\u0924\u0941 \u0915\u0940 \u091c\u093e\u0932\u0940 \u092e\u0947\u0902 \u0917\u0948\u0938 \u092b\u0901\u0938 \u091c\u093e\u0924\u0940 \u0939\u0948, \u0924\u094b \u0906\u0930\u094d\u0915 \u0915\u0940 \u0924\u0940\u0935\u094d\u0930 \u0917\u0930\u094d\u092e\u0940 \u0909\u0938\u0947 \u092e\u0941\u0915\u094d\u0924 \u0915\u0930 \u0926\u0947\u0917\u0940, \u091c\u093f\u0938\u0938\u0947 \u201c\u0935\u0930\u094d\u091a\u0941\u0905\u0932 \u0932\u0940\u0915\u201d \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0917\u093e \u091c\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094b \u0928\u0937\u094d\u091f \u0915\u0930 \u0926\u0947\u0917\u093e\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-the-metal-bellows-enabling-movement\">2. \u0927\u093e\u0924\u0941 \u0915\u093e \u092b\u0942\u0902\u0915\u0928\u093e: \u0917\u0924\u093f \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0928\u093e<\/h3>\n\n\n\n<p>\u092c\u0947\u0932\u094b\u091c\u093c \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0906\u0935\u0930\u0923 \u0915\u093e \u090f\u0915\u092e\u093e\u0924\u094d\u0930 \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u093e \u092d\u093e\u0917 \u0939\u0948\u0964 \u092f\u0939 \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094b \u0939\u0930\u094d\u092e\u0947\u091f\u093f\u0915 \u0938\u0940\u0932 \u091f\u0942\u091f\u0928\u0947 \u0915\u0947 \u092c\u093f\u0928\u093e \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u093e\u092e\u0917\u094d\u0930\u0940:<\/strong> \u0905\u0932\u094d\u091f\u094d\u0930\u093e-\u092a\u0924\u0932\u093e (0.1 \u092e\u093f\u092e\u0940 \u0938\u0947 0.15 \u092e\u093f\u092e\u0940) \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u092b\u0949\u0930\u094d\u092e\u094d\u0921 \u0938\u094d\u091f\u0947\u0928\u0932\u0947\u0938 \u0938\u094d\u091f\u0940\u0932 (AISI 316L) \u092f\u093e \u0907\u0928\u0915\u094b\u0928\u0947\u0932 718\u0964.<\/li>\n\n\n\n<li><strong>\u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u091f\u093f\u092a:<\/strong> \u092c\u0947\u0932\u094b\u091c\u093c \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0915\u092e\u091c\u094b\u0930 \u092c\u093f\u0902\u0926\u0941 \u0939\u0948\u0964 \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e \u0935\u0940\u0906\u0908\u091c\u093c \u092e\u0947\u0902 30,000 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 (M2 \u0936\u094d\u0930\u0947\u0923\u0940) \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u0921\u0902\u0921\u0947\u0902\u091f \u092a\u094d\u0932\u093e\u092f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092c\u0947\u0932\u094b\u091c\u093c \u0915\u094b \u092e\u0930\u094b\u0921\u093c\u0928\u0947 \u0935\u093e\u0932\u0940 \u0905\u0928\u0941\u091a\u093f\u0924 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u092e\u092f\u092a\u0942\u0930\u094d\u0935 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0947\u0917\u0940\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-the-insulating-envelope\">3. \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u093f\u0902\u0917 \u0932\u093f\u092b\u093e\u092b\u093e<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u093e\u092e\u0917\u094d\u0930\u0940:<\/strong> \u0909\u091a\u094d\u091a-\u0936\u094d\u0930\u0947\u0923\u0940 \u0915\u093e \u090f\u0932\u0941\u092e\u093f\u0928\u093e (<strong>\u090f\u0932\u094d\u092f\u0942\u092e\u093f\u0928\u093f\u092f\u092e \u0911\u0915\u094d\u0938\u093e\u0907\u0921<\/strong>) \u0938\u093f\u0930\u0947\u092e\u093f\u0915 (95%+ \u0936\u0941\u0926\u094d\u0927\u0924\u093e)\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092a\u0940\u0922\u093c\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0915\u093e\u0902\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0925\u093e, \u0932\u0947\u0915\u093f\u0928 \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u092c\u0947\u0939\u0924\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0914\u0930 \u0924\u093e\u092a\u0940\u092f \u091d\u091f\u0915\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0927\u093e\u0924\u0941\u0915\u0930\u0923:<\/strong> \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u0938\u093f\u0930\u094b\u0902 \u0915\u094b \u0927\u093e\u0924\u0941\u0915\u0930\u0923 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092e\u094b\u0932\u093f\u092c\u094d\u0921\u0947\u0928\u092e-\u092e\u0948\u0902\u0917\u0928\u0940\u091c \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947) \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u0924\u093e\u0915\u093f \u0927\u093e\u0924\u0941 \u092b\u094d\u0932\u0948\u0902\u091c\u094b\u0902 \u092a\u0930 \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917 \u0915\u0940 \u091c\u093e \u0938\u0915\u0947\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4-metal-vapor-shields\">4. \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0922\u093e\u0932\u0947\u0902<\/h3>\n\n\n\n<p>\u0935\u093f\u0915\u0930\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0935\u093f\u0938\u094d\u092b\u094b\u091f\u0915 \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0930\u094d\u0915 \u0917\u0948\u092a \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0918\u0947\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0915\u093e\u0930\u094d\u092f:<\/strong> \u091a\u093e\u0932\u0915 \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0915\u094b \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0924\u0939 \u092a\u0930 \u091c\u092e\u093e \u0939\u094b\u0928\u0947 \u0938\u0947 \u0930\u094b\u0915\u0924\u093e \u0939\u0948 (\u091c\u094b \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0947\u0917\u093e)\u0964.<\/li>\n\n\n\n<li><strong>\u0924\u0948\u0930\u0924\u093e \u0939\u0941\u0906 \u0938\u0902\u092d\u093e\u0935\u093f\u0924:<\/strong> \u0915\u0915\u094d\u0937 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u094b \u0938\u092e\u093e\u0928 \u0930\u0942\u092a \u0938\u0947 \u0935\u093f\u0924\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0922\u093e\u0932 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0930\u0942\u092a \u0938\u0947 \u092a\u0943\u0925\u0915 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<p>\u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0935\u093f\u0935\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e\u093e\u0930\u0940 \u0917\u093e\u0907\u0921 \u0926\u0947\u0916\u0947\u0902\u0964 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/vacuum-circuit-breaker-parts\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u092a\u0941\u0930\u094d\u091c\u0947<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-interrupter-longitudinal-cross-section\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0905\u0928\u0941\u0926\u0948\u0930\u094d\u0927\u094d\u092f \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"manufacturing-insight-one-shot-brazing\">\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0905\u0902\u0924\u0930\u094d\u0926\u0943\u0937\u094d\u091f\u093f: \u201c\u0935\u0928-\u0936\u0949\u091f\u201d \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917<\/h3>\n\n\n\n<p>VI \u0915\u0940 \u0938\u0902\u0930\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0905\u0916\u0902\u0921\u0924\u093e \u0907\u0938 \u092c\u093e\u0924 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948 \u0915\u093f \u092f\u0947 \u0918\u091f\u0915 \u0915\u0948\u0938\u0947 \u091c\u0941\u0921\u093c\u0947 \u0939\u0948\u0902\u0964 XBRELE \u091c\u0948\u0938\u0947 \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u090f\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <strong>\u201c\u090f\u0915-\u092c\u093e\u0930 \u0915\u0940 \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917\u201d<\/strong> \u0924\u0915\u0928\u0940\u0915\u0964 \u0915\u0908 \u0939\u0940\u091f\u093f\u0902\u0917 \u091a\u0915\u094d\u0930\u094b\u0902 \u0915\u0947 \u092c\u091c\u093e\u092f, \u091c\u094b \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0915\u092e\u091c\u094b\u0930 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0924\u0928\u093e\u0935 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0938\u092d\u0940 \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u090f\u0915 \u0939\u0940 \u0909\u091a\u094d\u091a-\u0936\u0942\u0928\u094d\u092f \u092d\u091f\u094d\u091f\u0940 \u092e\u0947\u0902 \u090f\u0915 \u0939\u0940 \u091a\u0915\u094d\u0930 \u092e\u0947\u0902 \u0905\u0938\u0947\u0902\u092c\u0932 \u0914\u0930 \u092c\u094d\u0930\u0947\u091c\u093c \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0909\u0924\u094d\u0924\u092e \u0905\u0915\u094d\u0937\u0940\u092f \u0938\u0902\u0930\u0947\u0916\u0923 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0927\u093e\u0924\u0941 \u0938\u0902\u0930\u091a\u0928\u093e \u092e\u0947\u0902 \u0924\u093e\u092a-\u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u094b \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-physics-of-arc-extinction-in-vacuum\">\u0936\u0942\u0928\u094d\u092f \u092e\u0947\u0902 \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f \u0915\u093e \u092d\u094c\u0924\u093f\u0915\u0940<\/h2>\n\n\n\n<p>\u0936\u0942\u0928\u094d\u092f \u092e\u0947\u0902 \u0906\u092f\u0928\u0940\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0915\u094b\u0908 \u0917\u0948\u0938 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964 \u0906\u0930\u094d\u0915 \u090f\u0915 \u0939\u0948\u0964 <strong>\u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0906\u0930\u094d\u0915<\/strong>, \u0906\u092f\u0928\u094b\u0902 (\u0935\u093e\u0937\u094d\u092a\u093f\u0924 Cu\/Cr) \u0914\u0930 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u093f\u0924 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0938\u092e\u0930\u094d\u0925\u093f\u0924 <strong>\u0915\u0948\u0925\u094b\u0921 \u0927\u092c\u094d\u092c\u0947<\/strong> (\u0928\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0930 \u092a\u093f\u0918\u0932\u0947 \u0939\u0941\u090f \u0927\u093e\u0924\u0941 \u0915\u0947 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0917\u0921\u094d\u0922\u0947)\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-current-zero-and-recovery\">1. \u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0936\u0942\u0928\u094d\u092f \u0914\u0930 \u0930\u093f\u0915\u0935\u0930\u0940<\/h3>\n\n\n\n<p>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0936\u0942\u0928\u094d\u092f (\u090f\u0938\u0940 \u091a\u0915\u094d\u0930) \u092a\u0930 \u090a\u0930\u094d\u091c\u093e \u0907\u0928\u092a\u0941\u091f \u0930\u0941\u0915 \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0915\u0948\u0925\u094b\u0921 \u0938\u094d\u092a\u0949\u091f\u094d\u0938 \u092c\u0941\u091d \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u092e\u0947\u0902 \u0935\u093f\u0938\u094d\u092b\u094b\u091f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092b\u0948\u0932\u0924\u0940 \u0939\u0948 (\u0932\u0917\u092d\u0917 1000 \u092e\u0940\u091f\u0930 \u092a\u094d\u0930\u0924\u093f \u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0917\u0924\u093f \u0938\u0947) \u0914\u0930 \u0936\u0940\u0932\u094d\u0921\u094d\u0938 \u0924\u0925\u093e \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u0938\u0902\u0918\u0928\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u0936\u0915\u094d\u0924\u093f \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0938\u0947\u0915\u0902\u0921\u094b\u0902 \u092e\u0947\u0902 \u092a\u0941\u0928\u0903 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u2014\u0909\u092d\u0930\u0924\u0947 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0935\u094b\u0932\u094d\u091f\u0947\u091c (TRV) \u0938\u0947 \u092d\u0940 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947, \u091c\u093f\u0938\u0938\u0947 \u092a\u0941\u0928\u0903 \u092a\u094d\u0930\u091c\u094d\u0935\u0932\u0928 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u093e\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-controlling-high-currents-amf-vs-rmf\">2. \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923: \u090f\u090f\u092e\u090f\u092b \u092c\u0928\u093e\u092e \u0906\u0930\u090f\u092e\u090f\u092b<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"920\" height=\"531\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry.webp\" alt=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f AMF (\u0905\u0915\u094d\u0937\u0940\u092f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930) \u0914\u0930 RMF (\u0905\u0930\u094d\u0927\u0935\u094d\u092f\u093e\u0938 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930) \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u094d\u092f\u093e\u092e\u093f\u0924\u093f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e\u0964.\" class=\"wp-image-2142\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry.webp 920w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry-300x173.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry-768x443.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry-18x10.webp 18w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/figure>\n\n\n\n<p>\u0909\u091a\u094d\u091a \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 (&gt;10 kA) \u092a\u0930, \u0906\u0930\u094d\u0915 \u0915\u093e \u0905\u092a\u0928\u093e \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0907\u0938\u0947 \u090f\u0915 \u0938\u0902\u0915\u0940\u0930\u094d\u0923, \u0905\u0924\u094d\u092f\u0902\u0924 \u0917\u0930\u094d\u092e \u0938\u094d\u0924\u0902\u092d \u092e\u0947\u0902 \u0938\u0902\u0915\u0941\u091a\u093f\u0924 \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948 \u091c\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0928\u0937\u094d\u091f \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930 \u0907\u0938 \u092a\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"radial-magnetic-field-rmf-the-rotator\">\u0930\u0947\u0921\u093f\u092f\u0932 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 (RMF) \u2013 \u201c\u0926 \u0930\u094b\u091f\u0947\u091f\u094b\u0930\u201d<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u0923\u093e\u0932\u0940:<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092e\u0947\u0902 \u0915\u091f\u0947 \u0939\u0941\u090f \u0938\u0930\u094d\u092a\u093f\u0932 \u0938\u094d\u0932\u0949\u091f \u0906\u0930\u094d\u0915 \u0915\u094b \u0935\u093f\u0935\u0936 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <strong>\u0918\u0941\u092e\u093e\u090f\u0901<\/strong> \u0932\u0949\u0930\u0947\u0902\u091c\u093c \u092c\u0932\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093f\u0928\u093e\u0930\u0947 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0924\u0940\u0935\u094d\u0930 \u0917\u0924\u093f \u0938\u0947\u0964.<\/li>\n\n\n\n<li><strong>\u0906\u0935\u0947\u0926\u0928:<\/strong> \u092e\u093e\u0928\u0915 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 (31.5kA \u0924\u0915) \u0915\u0947 \u0932\u093f\u090f \u0906\u0926\u0930\u094d\u0936\u0964.<\/li>\n\n\n\n<li><strong>\u092b\u093e\u092f\u0926\u0947:<\/strong> \u0938\u0930\u0932 \u0938\u0902\u0930\u091a\u0928\u093e, \u0905\u0924\u093f-\u0928\u093f\u092e\u094d\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0932\u093e\u0917\u0924-\u0915\u0941\u0936\u0932\u0964.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"axial-magnetic-field-amf-the-diffuser\">\u0905\u0915\u094d\u0937\u0940\u092f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 (AMF) \u2013 \u201c\u0921\u093f\u092b\u094d\u092f\u0942\u091c\u093c\u0930\u201d<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u0923\u093e\u0932\u0940:<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u0915\u0947 \u092a\u0940\u091b\u0947 \u0938\u094d\u0925\u093f\u0924 \u0915\u0941\u0902\u0921\u0932 \u090f\u0915 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <em>\u0938\u092e\u093e\u0902\u0924\u0930<\/em> \u0906\u0930\u094d\u0915 \u0915\u0949\u0932\u092e \u0915\u0940 \u0913\u0930\u0964 \u092f\u0939 \u092b\u094d\u0932\u0915\u094d\u0938 \u0932\u093e\u0907\u0928\u094b\u0902 \u092e\u0947\u0902 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u094b\u0902 \u0915\u094b \u092b\u0901\u0938\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u0930\u094d\u0915 \u092c\u0928\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964 <strong>\u0935\u093f\u0915\u0940\u0930\u094d\u0923\u093f\u0924<\/strong> (\u092a\u0942\u0930\u0947 \u0938\u0924\u0939 \u092a\u0930 \u092b\u0948\u0932\u093e \u0939\u0941\u0906) \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e\u0913\u0902 \u092a\u0930 \u092d\u0940\u0964.<\/li>\n\n\n\n<li><strong>\u0906\u0935\u0947\u0926\u0928:<\/strong> \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e (&gt;40kA) \u0914\u0930 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c (&gt;40.5kV) \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915\u0964.<\/li>\n\n\n\n<li><strong>\u092b\u093e\u092f\u0926\u0947:<\/strong> \u0928\u093f\u092e\u094d\u0928 \u0906\u0930\u094d\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0915\u094d\u0937\u092f \u092e\u0947\u0902 \u0909\u0932\u094d\u0932\u0947\u0916\u0928\u0940\u092f \u0915\u092e\u0940, \u0909\u091a\u094d\u091a \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u0928 \u0915\u094d\u0937\u092e\u0924\u093e\u0964.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u091a\u092f\u0928 \u091f\u093f\u092a:<\/strong> \u091c\u0928\u0930\u0947\u091f\u0930 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092f\u093e \u0939\u0948\u0935\u0940-\u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u093e\u0907\u0915\u093f\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091c\u0939\u093e\u0901 \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u0940\u0935\u0928 \u0938\u0930\u094d\u0935\u094b\u092a\u0930\u093f \u0939\u0948, <strong>\u090f\u090f\u092e\u090f\u092b<\/strong> \u0915\u092e \u0924\u093e\u092a\u0940\u092f \u0924\u0928\u093e\u0935 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0907\u0938\u0947 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u092e\u093e\u0928\u0915 \u0935\u093f\u0924\u0930\u0923 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u0947 \u0932\u093f\u090f, <strong>\u0906\u0930\u090f\u092e\u090f\u092b<\/strong> \u090f\u0915 \u092e\u091c\u092c\u0942\u0924 \u0914\u0930 \u0915\u093f\u092b\u093e\u092f\u0924\u0940 \u0938\u092e\u093e\u0927\u093e\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"critical-mechanical-parameters-for-oems\">OEMs \u0915\u0947 \u0932\u093f\u090f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/h2>\n\n\n\n<p>\u090f\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0905\u0932\u0917-\u0925\u0932\u0917 \u0915\u093e\u092e \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u093e; \u0907\u0938\u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0938\u091f\u0940\u0915 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0905\u092a\u0928\u0947 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092e\u0947\u0902 VI \u0915\u094b \u090f\u0915\u0940\u0915\u0943\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 OEM \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0924\u0940\u0928 \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0902:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-contact-pressure-force\">1. \u0938\u0902\u092a\u0930\u094d\u0915 \u0926\u092c\u093e\u0935 (\u092c\u0932)<\/h3>\n\n\n\n<p>\u091a\u0942\u0902\u0915\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u091f \u0938\u0902\u092a\u0930\u094d\u0915 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0935\u0947 \u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0914\u0930 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u201c\u092e\u0947\u0915\u201d \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092c\u093e\u0939\u0930\u0940 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0926\u092c\u093e\u0935 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e:<\/strong> \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 2000N \u0938\u0947 4000N \u0924\u0915\u0964 \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0926\u092c\u093e\u0935 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0947 \u0909\u091b\u0932\u0928\u0947 \u0914\u0930 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u093e \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-overtravel-contact-wipe\">2. \u0913\u0935\u0930\u091f\u094d\u0930\u0948\u0935\u0932 (\u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u093f\u091f\u093e\u0935)<\/h3>\n\n\n\n<p>\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0938\u094d\u092a\u0930\u094d\u0936 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u0924\u0902\u0924\u094d\u0930 \u0915\u094b \u091a\u0932\u0924\u0947 \u0930\u0939\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0907\u0938\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0926\u092c\u093e\u0935 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0938\u0902\u0915\u0941\u091a\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f:<\/strong> \u092f\u0939 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092e\u0947\u0902 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u093e\u0935 (\u0915\u094d\u0937\u0930\u0923) \u0915\u0940 \u092d\u0930\u092a\u093e\u0908 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092e\u093e\u0928\u0915 \u0913\u0935\u0930\u091f\u094d\u0930\u0948\u0935\u0932 3 \u092e\u093f\u092e\u0940 \u0938\u0947 4 \u092e\u093f\u092e\u0940 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-closing-bounce\">3. \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u092c\u093e\u0909\u0902\u0938<\/h3>\n\n\n\n<p>\u091c\u092c \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u094b\u0930 \u0938\u0947 \u092c\u0902\u0926 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0935\u0947 \u0938\u094d\u0935\u093e\u092d\u093e\u0935\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0909\u091b\u0932\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u0940\u092e\u093e:<\/strong> \u092c\u093e\u0909\u0902\u0938 \u0905\u0935\u0927\u093f 2 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0938\u0947 \u0915\u092e \u0939\u094b\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u092c\u093e\u0909\u0902\u0938 \u092a\u094d\u0930\u0940-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u093e \u0939\u0948, \u091c\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u0940 \u0935\u0947\u0932\u094d\u0921 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0907\u0938\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u092e\u0947\u0902 \u0938\u091f\u0940\u0915 \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"industry-trend-the-move-to-embedded-poles\">\u0909\u0926\u094d\u092f\u094b\u0917 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f: \u090f\u092e\u094d\u092c\u0947\u0921\u0947\u0921 \u092a\u094b\u0932 \u0915\u0940 \u0913\u0930 \u092c\u0922\u093c\u0928\u093e<\/h2>\n\n\n\n<p>\u0910\u0924\u093f\u0939\u093e\u0938\u093f\u0915 \u0930\u0942\u092a \u0938\u0947, \u0935\u0940\u0906\u0908\u090f\u0938 \u0915\u094b \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u093f\u0902\u0917 \u0938\u093f\u0932\u0947\u0902\u0921\u0930\u094b\u0902 (\u0907\u0915\u091f\u094d\u0920\u0947 \u0915\u093f\u090f \u0917\u090f \u092a\u094b\u0932) \u0915\u0947 \u0905\u0902\u0926\u0930 \u0932\u0917\u093e\u092f\u093e \u091c\u093e\u0924\u093e \u0925\u093e\u0964 \u0906\u0927\u0941\u0928\u093f\u0915 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0939\u0948 <a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/\"><strong>\u0920\u094b\u0938 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0928\u093f\u0939\u093f\u0924 \u0916\u0902\u092d\u0947<\/strong><\/a>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u094c\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u0940:<\/strong> \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094b \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0926\u092c\u093e\u0935 \u091c\u0947\u0932\u0928 (APG) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0938\u0940\u0927\u0947 \u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0930\u0947\u091c\u093c\u093f\u0928 \u092f\u093e \u0925\u0930\u094d\u092e\u094b\u092a\u094d\u0932\u093e\u0938\u094d\u091f\u093f\u0915 \u092e\u0947\u0902 \u0922\u093e\u0932\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0932\u093e\u092d:<\/strong>\n<ol class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0938\u0902\u0930\u0915\u094d\u0937\u0923:<\/strong> \u0935\u0940\u0906\u0908 \u0927\u0942\u0932, \u0928\u092e\u0940 \u0914\u0930 \u0938\u0902\u0918\u0928\u0928 \u0938\u0947 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0938\u0940\u0932 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940:<\/strong> \u092c\u093e\u0939\u0930\u0940 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0905\u0938\u0902\u092d\u0935 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0941\u0915\u094d\u0924:<\/strong> VI \u0938\u0924\u0939 \u0915\u0940 \u0938\u092b\u093e\u0908 \u0915\u0940 \u0915\u094b\u0908 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u0939\u0948\u0964 \u0905\u0927\u093f\u0915\u093e\u0902\u0936 XBRELE \u0938\u092e\u093e\u0927\u093e\u0928 \u0905\u092c \u0915\u0920\u094b\u0930 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0905\u0927\u093f\u0915\u0924\u092e \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u0907\u0938 \u090f\u092e\u094d\u092c\u0947\u0921\u0947\u0921 \u092a\u094b\u0932 \u0924\u0915\u0928\u0940\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n<\/ol>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-determines-the-lifetime-of-a-vacuum-interrupter\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094d\u092f\u093e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-contact-erosion-electrical-life\">1. \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923 (\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091c\u0940\u0935\u0928)<\/h3>\n\n\n\n<p>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0905\u092a\u0928\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092e\u0947\u0902 \u0932\u0917\u092d\u0917 1\u20133 \u092e\u093f\u092e\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u094b \u0935\u093e\u0937\u094d\u092a\u0940\u0915\u0943\u0924 \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 XBRELE VIs \u092e\u093e\u0928\u0926\u0902\u0921\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 <strong>\u0935\u0930\u094d\u0917 \u09082<\/strong> (IEC 62271-100), \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u092c\u093f\u0928\u093e \u0935\u093f\u0938\u094d\u0924\u093e\u0930\u093f\u0924 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0902\u091a\u093e\u0932\u0928 \u092e\u0947\u0902 \u0938\u0915\u094d\u0937\u092e\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-vacuum-integrity-shelf-life\">2. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e (\u0936\u0947\u0932\u094d\u092b \u0932\u093e\u0907\u092b)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0930\u093f\u0938\u093e\u0935 \u0926\u0930:<\/strong> \u092f\u0939 10\u207b\u2077 Pa\u00b7L\/s \u0938\u0947 \u0915\u092e \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u0915\u0930\u094d\u0924\u093e:<\/strong> \u092c\u094b\u0924\u0932 \u0915\u0947 \u0905\u0902\u0926\u0930 \u092e\u094c\u091c\u0942\u0926 \u091c\u093c\u093f\u0930\u0915\u094b\u0928\u093f\u092f\u092e-\u0906\u0927\u093e\u0930\u093f\u0924 \u0917\u0947\u091f\u0930\u094d\u0938 20\u201330 \u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u093f\u0924 \u0905\u0923\u0941\u0913\u0902 \u0915\u094b \u0905\u0935\u0936\u094b\u0937\u093f\u0924 \u0915\u0930 \u0932\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-failure-diagnostics\">3. \u0935\u093f\u092b\u0932\u0924\u093e \u0928\u093f\u0926\u093e\u0928<\/h3>\n\n\n\n<p>\u0906\u092a \u0915\u0948\u0938\u0947 \u091c\u093e\u0928\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u090f\u0915 VI \u0935\u093f\u092b\u0932 \u0939\u094b \u0917\u092f\u093e \u0939\u0948?<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0928\u0941\u0915\u0938\u093e\u0928:<\/strong> \u090f\u0915\u092e\u093e\u0924\u094d\u0930 \u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u090f\u0915 \u0939\u0948\u0964 <strong>\u0935\u093f\u0921\u093e\u0930 (\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0939\u0928) \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>. \u092f\u0926\u093f \u092f\u0939 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u091a\u092e\u0915\u0924\u093e \u0939\u0948, \u0924\u094b \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b \u0917\u092f\u093e \u0939\u0948\u0964.<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0938\u094d\u0924\u094d\u0930:<\/strong> \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u094b\u0932 \u092a\u0930 \u0918\u093f\u0938\u093e\u0935 \u0938\u0902\u0915\u0947\u0924\u0915 \u0915\u0940 \u0926\u0943\u0936\u094d\u092f \u091c\u093e\u0901\u091a\u0964.<\/li>\n\n\n\n<li><strong>\u0905\u0924\u093f \u0924\u093e\u092a:<\/strong> \u092c\u0922\u093c\u0940 \u0939\u0941\u0908 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u092e \u092e\u0940\u091f\u0930 \u0938\u0947 \u092e\u093e\u092a\u093e \u0917\u092f\u093e) \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u092f\u093e \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0926\u092c\u093e\u0935 \u0915\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions-faqs\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928 (FAQs)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-life-expectancy-of-a-vacuum-interrupter\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0940 \u0906\u092f\u0941 \u0915\u094d\u092f\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u090f\u0915 \u0909\u091a\u094d\u091a-\u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0935\u093e\u0932\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092e\u0947\u0902 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u090f\u0915 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 <strong>20 \u0938\u0947 30 \u0935\u0930\u094d\u0937 \u0915\u093e \u0938\u0947\u0935\u093e \u091c\u0940\u0935\u0928<\/strong>. \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0930\u0942\u092a \u0938\u0947, \u092e\u093e\u0928\u0915 \u0935\u0940\u0906\u0908 \u0915\u094b <strong>\u0915\u094d\u0932\u093e\u0938 M2 (10,000 \u0938\u0947 30,000 \u0938\u0902\u091a\u093e\u0932\u0928)<\/strong>. \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0930\u0942\u092a \u0938\u0947, \u0935\u0947 \u0938\u0939\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 <strong>\u0915\u094d\u0932\u093e\u0938 E2 (100 \u092a\u0942\u0930\u094d\u0923 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0924\u0915)<\/strong> \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0914\u0930 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-you-check-the-vacuum-in-a-circuit-breaker\">\u0906\u092a \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0948\u0938\u0947 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u092e\u0948\u0926\u093e\u0928 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0928\u0947 \u0915\u093e \u090f\u0915\u092e\u093e\u0924\u094d\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0924\u0930\u0940\u0915\u093e \u0939\u0948 \u090f\u0915 <strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092c\u094b\u0924\u0932 \u092a\u0930\u0940\u0915\u094d\u0937\u0915 (\u0935\u093f\u0921\u093e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923)<\/strong>. \u0907\u0938\u092e\u0947\u0902 \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u0909\u091a\u094d\u091a DC \u092f\u093e AC \u0935\u094b\u0932\u094d\u091f\u0947\u091c (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0930\u0947\u091f\u0947\u0921 \u092a\u093e\u0935\u0930 \u092b\u094d\u0930\u093f\u0915\u094d\u0935\u0947\u0902\u0938\u0940 \u0938\u0939\u0928\u0936\u0940\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e 75%) \u0932\u093e\u0917\u0942 \u0915\u0930\u0928\u093e \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0964 \u092f\u0926\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u093f\u0924 \u0939\u0948, \u0924\u094b \u0930\u093f\u0938\u093e\u0935 \u0927\u093e\u0930\u093e \u0928\u0917\u0923\u094d\u092f \u0939\u094b\u0924\u0940 \u0939\u0948; \u092f\u0926\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0939\u0948, \u0924\u094b \u0924\u0941\u0930\u0902\u0924 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0939\u094b \u091c\u093e\u090f\u0917\u093e\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-are-the-disadvantages-of-a-vacuum-circuit-breaker\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0915\u094d\u092f\u093e \u0928\u0941\u0915\u0938\u093e\u0928 \u0939\u0948\u0902?<\/h3>\n\n\n\n<p>\u092e\u0941\u0916\u094d\u092f \u0928\u0941\u0915\u0938\u093e\u0928 \u091c\u094b\u0916\u093f\u092e \u0915\u093e \u0939\u0948 <strong>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0915\u091f\u093e\u0908<\/strong> \u091b\u094b\u091f\u0947 \u092a\u094d\u0930\u0947\u0930\u0915 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0938\u092e\u092f, \u091c\u094b \u0915\u094d\u0937\u0923\u093f\u0915 \u0905\u0927\u093f\u0935\u094b\u0932\u094d\u091f\u0947\u091c (V = L \u00b7 di\/dt) \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0938\u0915\u0947 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0928 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 <strong>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u0915\u092e \u0915\u093f\u092b\u093e\u092f\u0924\u0940<\/strong> (72.5 kV \u092f\u093e 145 kV \u0938\u0947 \u090a\u092a\u0930) \u091c\u0939\u093e\u0901 SF6 \u0935\u093f\u0915\u0932\u094d\u092a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u092e\u0947\u0902 \u0915\u0908 \u092c\u094d\u0930\u0947\u0915 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-contact-material-is-used-in-vacuum-interrupters\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u092e\u0947\u0902 \u0915\u094c\u0928 \u0938\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0939\u0948 <strong>\u0924\u093e\u0902\u092c\u093e-\u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e (CuCr)<\/strong>, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 50\/50 \u092f\u093e 75\/25 \u0915\u0947 \u0905\u0928\u0941\u092a\u093e\u0924 \u092e\u0947\u0902\u0964 \u0907\u0938 \u092e\u093f\u0936\u094d\u0930\u0927\u093e\u0924\u0941 \u0915\u094b \u0907\u0938\u0932\u093f\u090f \u091a\u0941\u0928\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0924\u093e\u0902\u092c\u093e \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091a\u093e\u0932\u0915\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f \u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e \u0909\u091a\u094d\u091a \u0917\u0932\u0928\u093e\u0902\u0915 \u0914\u0930 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u0917\u0948\u0938\u094b\u0902 \u0915\u094b \u0905\u0935\u0936\u094b\u0937\u093f\u0924 \u0915\u0930\u0928\u0947 \u0924\u0925\u093e \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0940 \u092e\u091c\u092c\u0942\u0924 \u201c\u0917\u0947\u091f\u0930\u093f\u0902\u0917\u201d \u0915\u094d\u0937\u092e\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-are-vacuum-circuit-breakers-preferred-over-sf6\">SF6 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u094b \u0915\u094d\u092f\u094b\u0902 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948?<\/h3>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u094b \u0907\u0938\u0932\u093f\u090f \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0935\u0947 <strong>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0915\u0947 \u0905\u0928\u0941\u0915\u0942\u0932 (\u0936\u0942\u0928\u094d\u092f \u0939\u0930\u093f\u0924\u0917\u0943\u0939 \u0917\u0948\u0938 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928)<\/strong> \u0914\u0930 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e <strong>\u0932\u0917\u092d\u0917 \u0915\u094b\u0908 \u0930\u0916\u0930\u0916\u093e\u0935 \u0928\u0939\u0940\u0902<\/strong>. \u091c\u092c\u0915\u093f SF6 \u090f\u0915 \u0936\u0915\u094d\u0924\u093f\u0936\u093e\u0932\u0940 \u0917\u094d\u0930\u0940\u0928\u0939\u093e\u0909\u0938 \u0917\u0948\u0938 \u0939\u0948 \u091c\u093f\u0938\u0947 \u0915\u0921\u093c\u0947 \u0935\u0948\u0936\u094d\u0935\u093f\u0915 \u091a\u0930\u0923-\u0906\u0909\u091f \u0928\u093f\u092f\u092e\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u0924\u093e \u0939\u0948, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0924\u0915\u0928\u0940\u0915 \u091f\u093f\u0915\u093e\u090a \u0939\u0948, \u0909\u091a\u094d\u091a \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948, \u0914\u0930 \u0917\u0948\u0938 \u0930\u093f\u0938\u093e\u0935 \u0915\u0947 \u091c\u094b\u0916\u093f\u092e \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-internal-pressure-of-a-vacuum-interrupter\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u092c\u093e\u0935 \u0915\u094d\u092f\u093e \u0939\u0948?<\/h3>\n\n\n\n<p>\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u092c\u093e\u0935 \u0915\u094b \u0938\u0947 \u0915\u092e \u0915\u0930 \u0926\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 <strong>10\u207b\u2075 \u092a\u093e\u0938\u094d\u0915\u0932<\/strong>. \u0915\u093f\u0938\u0940 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092e\u0947\u0902 \u0905\u092a\u0928\u0947 \u0938\u0902\u092a\u0942\u0930\u094d\u0923 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u092a\u0928\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0930\u094b\u0927\u0915 \u0915\u094d\u0937\u092e\u0924\u093e \u0914\u0930 \u0906\u0930\u094d\u0915-\u0928\u093f\u0937\u094d\u0915\u093e\u0938\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u092c\u093e\u0935 \u0915\u094b \u0915\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0940\u092e\u093e \u0938\u0947 \u0928\u0940\u091a\u0947 \u0930\u0916\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 <strong>10\u207b\u00b2 \u092a\u093e\u0938\u094d\u0915\u0932<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-a-vacuum-interrupter-be-repaired-or-refilled\">\u0915\u094d\u092f\u093e \u090f\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u092f\u093e \u092a\u0941\u0928\u0903 \u092d\u0930\u093e\u0908 \u0915\u0940 \u091c\u093e \u0938\u0915\u0924\u0940 \u0939\u0948?<\/h3>\n\n\n\n<p><strong>\u0928\u0939\u0940\u0902, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0928\u0939\u0940\u0902 \u0915\u0940 \u091c\u093e \u0938\u0915\u0924\u0940\u0964.<\/strong> \u092f\u0939 \u090f\u0915 \u0939\u0930\u094d\u092e\u0947\u091f\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u0940\u0932\u092c\u0902\u0926 \u0907\u0915\u093e\u0908 \u0939\u0948 \u091c\u093f\u0938\u092e\u0947\u0902 \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u0914\u0930 \u0927\u093e\u0924\u0941 \u0915\u0947 \u092c\u0940\u091a \u092c\u094d\u0930\u0947\u091c\u093c\u0947\u0921 \u091c\u094b\u0921\u093c \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u090f\u0915 \u092c\u093e\u0930 \u091c\u092c \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0940\u0932 \u091f\u0942\u091f \u091c\u093e\u0924\u0940 \u0939\u0948 \u092f\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0928\u0940 \u0938\u0940\u092e\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u094d\u0937\u092f\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u092a\u0942\u0930\u0947 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 (\u092f\u093e \u090f\u092e\u094d\u092c\u0947\u0921\u0947\u0921 \u092a\u094b\u0932) \u0915\u094b \u092c\u0926\u0932\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion-selecting-for-reliability\">\u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937: \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u091a\u092f\u0928<\/h2>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0906\u0927\u0941\u0928\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u093e \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0918\u091f\u0915 \u0939\u0948\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f, \u0906\u0902\u0924\u0930\u093f\u0915 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917, \u0909\u091a\u094d\u091a-\u0936\u0941\u0926\u094d\u0927\u0924\u093e \u0935\u093e\u0932\u0947 CuCr \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0914\u0930 \u0938\u091f\u0940\u0915 AMF \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0935\u093e\u0932\u093e \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e VI \u0926\u0936\u0915\u094b\u0902 \u0924\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u092d\u093f\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u0938\u093e\u091d\u0947\u0926\u093e\u0930\u0940 \u0915\u0930\u0947\u0902<\/strong> \u092a\u0930 <strong>\u090f\u0915\u094d\u0938\u092c\u0940\u0906\u0930\u0908\u090f\u0932\u0908<\/strong>, \u0939\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u093e \u0905\u092d\u093f\u092f\u093e\u0902\u0924\u094d\u0930\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u092e\u093e\u0930\u0947 \u0935\u0940\u0906\u0908\u090f\u0938 \u092a\u093e\u0930 \u0915\u0930 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 <a href=\"https:\/\/www.google.com\/search?q=https:\/\/webstore.iec.ch\/publication\/62271\" target=\"_blank\" rel=\"noopener\"><strong>\u0906\u0908\u0908\u0938\u0940 62271-100<\/strong><\/a> \u0914\u0930 <strong>\u090f\u090f\u0928\u090f\u0938\u0906\u0908\/\u0906\u0908\u0908\u0908\u0908 \u0938\u094037.60<\/strong> \u092e\u093e\u0928\u0915\u0964 \u091a\u093e\u0939\u0947 \u090f\u0915\u0940\u0915\u0943\u0924 VCBs \u0939\u094b\u0902 \u092f\u093e OEM \u0906\u092a\u0942\u0930\u094d\u0924\u093f, \u0939\u092e \u0906\u092a\u0915\u0947 \u0917\u094d\u0930\u093f\u0921 \u0915\u094b \u0936\u0915\u094d\u0924\u093f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<div class=\"xbrele-classic-card\">\n    <div class=\"card-inner\">\n        <div class=\"card-thumb\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/download-icon.webp\" alt=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0924\u0915\u0928\u0940\u0915\u0940 \u092a\u0940\u0921\u0940\u090f\u092b\">\n        <\/div>\n        \n        <div class=\"card-details\">\n            <span class=\"card-label\">\u0906\u0927\u093f\u0915\u093e\u0930\u093f\u0915 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e<\/span>\n            <h3>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094d\u092f\u093e \u0939\u0948? \u0915\u093e\u0930\u094d\u092f \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0914\u0930 \u0924\u0915\u0928\u0940\u0915\u0940 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e<\/h3>\n            <p>\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u201c\u0939\u0943\u0926\u092f\u201d \u092e\u0947\u0902 \u0917\u0939\u0928 \u0905\u0928\u094d\u0935\u0947\u0937\u0923\u0964   \u092f\u0939 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e \u0909\u091a\u094d\u091a \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u092e\u0947\u0902 \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f \u092d\u094c\u0924\u093f\u0915\u0940, \u0938\u093f\u0930\u0947\u092e\u093f\u0915-\u0938\u0947-\u0927\u093e\u0924\u0941 \u092c\u094d\u0930\u0947\u091c\u093c\u093f\u0902\u0917 \u0924\u0915\u0928\u0940\u0915, \u0914\u0930 CuCr \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0935\u093f\u091c\u094d\u091e\u093e\u0928 \u0915\u094b \u0915\u0935\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n            \n            <div class=\"card-meta\">\n                <span><i class=\"far fa-file-pdf\"><\/i> \u0938\u094d\u0935\u0930\u0942\u092a: \u092a\u0940\u0921\u0940\u090f\u092b \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c<\/span>\n                <span><i class=\"far fa-user\"><\/i> \u0932\u0947\u0916\u093f\u0915\u093e: \u0939\u0928\u094d\u0928\u093e \u091d\u0942<\/span>\n            <\/div>\n            \n            <a href=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele.com-What-Is-a-Vacuum-Interrupter.pdf\" class=\"card-download-btn\" target=\"_blank\" rel=\"noopener\">\n                <i class=\"fas fa-file-download\"><\/i> \u0935\u0940\u0906\u0908 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0917\u093e\u0907\u0921 \u0921\u093e\u0909\u0928\u0932\u094b\u0921 \u0915\u0930\u0947\u0902\n            <\/a>\n        <\/div>\n    <\/div>\n<\/div>\n\n<style>\n\/* XBRELE \u7ecf\u5178\u5de5\u4e1a\u98ce\u683c - \u54c1\u724c\u8272 #0fb4ad *\/\n.xbrele-classic-card {\n    background: #fdfdfd;\n    border: 1px solid #e1e4e8;\n    border-left: 6px solid #0fb4ad; \/* \u54c1\u724c\u9752\u7eff\u8272\u4fa7\u8fb9\u6761 *\/\n    padding: 28px;\n    margin: 35px 0;\n    border-radius: 4px;\n    box-shadow: 0 2px 12px rgba(0,0,0,0.04);\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n}\n\n.card-inner {\n    display: flex;\n    gap: 30px;\n    align-items: center;\n}\n\n.card-thumb img {\n    width: 130px; \n    height: auto;\n    border-radius: 2px;\n}\n\n.card-label {\n    color: #0fb4ad;\n    font-size: 12px;\n    text-transform: uppercase;\n    font-weight: 800;\n    letter-spacing: 1.2px;\n    margin-bottom: 6px;\n    display: block;\n}\n\n.card-details h3 {\n    margin: 5px 0 10px 0;\n    font-size: 22px;\n    color: #1a1a1a;\n    line-height: 1.3;\n}\n\n.card-details p {\n    font-size: 14.5px;\n    color: #586069;\n    margin-bottom: 18px;\n    line-height: 1.5;\n}\n\n.card-meta {\n    font-size: 13px;\n    color: #959da5;\n    margin-bottom: 22px;\n    display: flex;\n    gap: 20px;\n}\n\n.card-meta i {\n    color: #0fb4ad;\n    margin-right: 5px;\n}\n\n.card-download-btn {\n    display: inline-flex;\n    align-items: center;\n    gap: 10px;\n    background-color: #0fb4ad;\n    color: #ffffff !important;\n    padding: 12px 28px;\n    border-radius: 3px;\n    text-decoration: none !important;\n    font-weight: 700;\n    font-size: 15px;\n    transition: all 0.25s ease;\n    box-shadow: 0 4px 10px rgba(15, 180, 173, 0.2);\n}\n\n.card-download-btn:hover {\n    background-color: #0d9b94;\n    box-shadow: 0 6px 15px rgba(15, 180, 173, 0.3);\n    transform: translateY(-1px);\n}\n\n\/* \u54cd\u5e94\u5f0f\u9002\u914d\u79fb\u52a8\u7aef *\/\n@media (max-width: 650px) {\n    .card-inner { flex-direction: column; text-align: center; }\n    .card-thumb img { width: 100px; }\n    .card-meta { justify-content: center; }\n}\n<\/style>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u092a\u0920\u0928 \u0914\u0930 \u091a\u092f\u0928 \u0938\u0902\u0938\u093e\u0927\u0928<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/hi\/products\/\">\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u0924\u094d\u092a\u093e\u0926 \u0905\u0935\u0932\u094b\u0915\u0928<\/a> \u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u091c\u093e\u0901\u091a\u0947\u0902, \u0938\u0940\u092e\u093e\u090f\u0901, \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0928\u094b\u091f\u094d\u0938<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Executive Summary: Engineering Quick View The &#8220;Heart&#8221; of VCBs: The Vacuum Interrupter (VI) is the globally accepted standard for medium-voltage switching, utilizing Metal Vapor Arc Extinction in a high-vacuum chamber (< 10\u207b\u2075 Pa) to interrupt massive fault currents. Core Technology: Uses CuCr (Copper-Chromium) contacts to prevent welding and ensure rapid dielectric recovery (Paschen\u2019s Law). Arc [&hellip;]\n<\/p>\n","protected":false},"author":3,"featured_media":2140,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27,24],"tags":[],"class_list":["post-2137","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2137","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2137"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2137\/revisions"}],"predecessor-version":[{"id":3634,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2137\/revisions\/3634"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2140"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2137"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2137"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2137"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}