{"id":2392,"date":"2026-01-02T08:14:43","date_gmt":"2026-01-02T08:14:43","guid":{"rendered":"https:\/\/xbrele.com\/?p=2392"},"modified":"2026-04-07T13:47:09","modified_gmt":"2026-04-07T13:47:09","slug":"capacitor-bank-switching-inrush-pre-insertion","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/capacitor-bank-switching-inrush-pre-insertion\/","title":{"rendered":"\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917: \u0907\u0928\u0930\u0936, \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928, \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f"},"content":{"rendered":"<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u093e \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u0938\u092c\u0938\u0947 \u0917\u0902\u092d\u0940\u0930 \u0915\u094d\u0937\u0923\u093f\u0915 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u092a\u0939\u0932\u0947 \u0905\u0930\u094d\u0927\u091a\u0915\u094d\u0930 \u092e\u0947\u0902 \u0930\u0947\u091f\u0947\u0921 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0930\u0902\u091f \u0915\u093e 20\u2013100 \u0917\u0941\u0928\u093e \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u094b \u0915\u094d\u0937\u0940\u0923 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 5\u201310 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u092c\u0928\u093e \u0930\u0939\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0918\u091f\u0928\u093e \u092e\u093e\u0928\u0915 AC-3 \u092f\u093e AC-4 \u0930\u0947\u091f\u0947\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u0940 \u092c\u0928\u093e\u0928\u0947 \u0915\u0940 \u0915\u094d\u0937\u092e\u0924\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917, \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0915\u094d\u0937\u0930\u0923 \u0914\u0930 \u0938\u092e\u092f\u092a\u0942\u0930\u094d\u0935 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u092c \u0924\u0915 \u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0928 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u094b\u0964.<\/p>\n\n\n\n<p>\u0938\u092e\u0938\u094d\u092f\u093e \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u092a\u093e\u0935\u0930 \u092b\u0948\u0915\u094d\u091f\u0930 \u0938\u0941\u0927\u093e\u0930 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0914\u0930 \u092c\u0922\u093c \u091c\u093e\u0924\u0940 \u0939\u0948 \u091c\u0939\u093e\u0901 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092a\u094d\u0930\u0924\u093f \u0918\u0902\u091f\u0947 \u0915\u0908 \u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 12 kV, 5 MVAR \u0915\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u091c\u094b 240 A \u0938\u094d\u0925\u093f\u0930-\u0938\u094d\u0925\u093f\u0924\u093f \u0927\u093e\u0930\u093e \u0916\u0940\u0902\u091a\u0924\u093e \u0939\u0948, 12 kA \u0907\u0928\u0930\u0936 \u092a\u0940\u0915\u2014\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0927\u093e\u0930\u093e \u0915\u093e 50 \u0917\u0941\u0928\u093e\u2014\u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0914\u0930 \u090a\u092a\u0930\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u092a\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0926\u092c\u093e\u0935 \u092a\u0921\u093c\u0924\u093e \u0939\u0948\u0964 \u0909\u091a\u093f\u0924 \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0947 \u092c\u093f\u0928\u093e, \u092f\u093e \u0924\u094b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u0947\u0932\u094d\u0921 \u0939\u094b\u0915\u0930 \u092c\u0902\u0926 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 \u092f\u093e \u090a\u092a\u0930\u0940 \u092b\u094d\u092f\u0942\u091c \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0909\u0921\u093c \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0915\u093e \u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u092d\u094c\u0924\u093f\u0915 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924, \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u0947 \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923, \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 (AC-6b) \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u091a\u092f\u0928, \u0914\u0930 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0926\u0942\u0930 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u091f\u094d\u0930\u093f\u092a \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917: \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0914\u0930 \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/lkBZRcl1j2g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-capacitor-inrush-exceeds-motor-starting-current\">\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 \u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u093f\u0902\u0917 \u0915\u0930\u0902\u091f \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u094d\u092f\u094b\u0902 \u0939\u094b\u0924\u093e \u0939\u0948<\/h2>\n\n\n\n<p>\u092e\u094b\u091f\u0930 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0938\u0940\u092e\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u2014\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0938\u094d\u0915\u094d\u0935\u093f\u0930\u0932-\u0915\u0947\u091c \u092e\u094b\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u092a\u0942\u0930\u094d\u0923-\u092d\u093e\u0930 \u0927\u093e\u0930\u093e \u0915\u093e 6\u20138 \u0917\u0941\u0928\u093e\u0964  \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0940 \u0928\u093f\u0930\u094d\u0935\u093f\u0924\u094d\u0924\u0940\u0915\u0943\u0924 \u0938\u094d\u0925\u093f\u0924\u093f \u0914\u0930 \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0938\u0940\u092e\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092e\u0942\u0932 \u0930\u0942\u092a \u0938\u0947 \u092d\u093f\u0928\u094d\u0928 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u091c\u092c \u090f\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0921\u093f\u0938\u094d\u091a\u093e\u0930\u094d\u091c \u0915\u093f\u090f \u0917\u090f \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u092a\u0930 \u092c\u0902\u0926 \u0939\u094b\u0924\u093e \u0939\u0948, \u0924\u094b \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092a\u0939\u0932\u0947 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0938\u0947\u0915\u0902\u0921\u094b\u0902 \u0924\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0924\u093e \u0939\u0948 \u091c\u092c \u0924\u0915 \u0909\u0938\u0915\u0940 \u092a\u094d\u0932\u0947\u091f\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0915\u0938\u093f\u0924 \u0928\u0939\u0940\u0902 \u0939\u094b \u091c\u093e\u0924\u093e\u0964 \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e (\u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930, \u0915\u0947\u092c\u0932, \u092c\u0938\u092c\u093e\u0930) \u092a\u0940\u0915 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948:<\/p>\n\n\n\n<p><strong>\u0936\u093f\u0916\u0930 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e (\u092a\u094d\u0930\u0925\u092e \u0905\u0930\u094d\u0927-\u091a\u0915\u094d\u0930)<\/strong>:<br>I<sub>\u0936\u093f\u0916\u0930, \u091a\u0930\u092e, \u092a\u0930\u092e, \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u0909\u0924\u094d\u0924\u092e, \u0938\u0930\u094d\u0935\u094b\u091a\u094d\u091a, \u092a\u0930\u092e \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u092a\u0930<\/sub>\u00a0= \u0935\u0940<sub>\u092a\u094d\u0930\u0923\u093e\u0932\u0940<\/sub>\u00a0\/ (\u091c\u093c\u0947\u0921<sub>\u0938\u094d\u0930\u094b\u0924<\/sub>\u00a0+ \u091c\u093c\u0947\u0921<sub>\u0915\u0947\u092c\u0932<\/sub>)<br>0.5 \u03a9 \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0935\u093e\u0932\u0947 12 kV \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0932\u093f\u090f:<br>I<sub>\u0936\u093f\u0916\u0930, \u091a\u0930\u092e, \u092a\u0930\u092e, \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u0909\u0924\u094d\u0924\u092e, \u0938\u0930\u094d\u0935\u094b\u091a\u094d\u091a, \u092a\u0930\u092e \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u092a\u0930<\/sub>\u00a0= (12,000 V \u00d7 \u221a2) \/ 0.5 \u03a9 \u2248\u00a0<strong>34 \u0915\u093f\u0932\u094b\u090f\u092e\u094d\u092a\u093f\u092f\u0930<\/strong><\/p>\n\n\n\n<p>\u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0915\u0947\u092c\u0932 \u0915\u0940 \u0907\u0902\u0921\u0915\u094d\u091f\u0947\u0902\u0938 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0936\u093f\u0916\u0930 \u092e\u093e\u0928 (8\u201315 kA) \u0915\u092e \u0926\u0947\u0916\u0947 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0932\u0947\u0915\u093f\u0928 10 kA \u0915\u093e \u0907\u0928\u0930\u0936 \u092d\u0940 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0940 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0915\u093e 40\u201350 \u0917\u0941\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u2014\u091c\u094b AC-4 \u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u093f\u0902\u0917 \u0936\u094d\u0930\u0947\u0923\u0940 (\u091c\u094b 6\u20138 \u0917\u0941\u0928\u093e \u0907\u0928\u0930\u0936 \u092e\u093e\u0928\u0924\u0940 \u0939\u0948) \u0938\u0947 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0938\u093e\u092e\u0917\u094d\u0930\u0940<\/strong>&nbsp;\u092f\u0939 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0930\u0942\u092a \u0938\u0947 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092e\u094b\u091f\u0930 \u0907\u0928\u0930\u0936 \u092e\u0947\u0902 \u092e\u0942\u0932 \u0906\u0935\u0943\u0924\u094d\u0924\u093f (50\/60 \u0939\u0930\u094d\u091f\u094d\u091c\u093c) \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 \u092e\u0947\u0902 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0907\u0902\u0921\u0915\u094d\u091f\u0947\u0902\u0938 \u0914\u0930 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0915\u0947 \u092c\u0940\u091a LC \u0905\u0928\u0941\u0928\u093e\u0926 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0918\u091f\u0915 (500 \u0939\u0930\u094d\u091f\u094d\u091c\u093c \u2013 5 \u0915\u093f\u0932\u094b\u0939\u0930\u094d\u091f\u094d\u091c\u093c) \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0909\u091a\u094d\u091a \u0906\u0935\u0943\u0924\u094d\u0924\u093f\u092f\u093e\u0901 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u0932\u0917\u093e\u0935 \u092a\u0930 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0918\u0928\u0924\u094d\u0935 \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u0940 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0915\u094d\u0937\u0930\u0923 \u092e\u0947\u0902 \u0924\u0947\u091c\u0940 \u0906\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u092e\u091d\u0928\u093e&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0906\u0930\u094d\u0915 \u0915\u094b \u0915\u0948\u0938\u0947 \u092c\u0941\u091d\u093e\u0924\u0947 \u0939\u0948\u0902<\/a>&nbsp;\u092f\u0939 \u0938\u0902\u0926\u0930\u094d\u092d \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0914\u0930 \u092c\u0922\u093c\u0940 \u0939\u0941\u0908 \u092a\u094d\u0930\u0940-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0926\u0942\u0930\u0940 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0915\u094d\u092f\u094b\u0902 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01.webp\" alt=\"\u0913\u0938\u093f\u0932\u094b\u0938\u094d\u0915\u094b\u092a \u0926\u094d\u0935\u093e\u0930\u093e \u0932\u093f\u090f \u0917\u090f \u091f\u094d\u0930\u0947\u0938, \u091c\u094b \u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u093f\u0902\u0917 \u0907\u0928\u0930\u0936 (6\u00d7 \u092a\u0930\u093f\u092e\u093e\u0923) \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0907\u0928\u0930\u0936 (40\u00d7 \u092a\u0930\u093f\u092e\u093e\u0923) \u0938\u0947 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u092e\u0947\u0902 \u0909\u091a\u094d\u091a \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u092e\u094d\u092a\u0928 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947 \u0930\u0939\u0940 \u0939\u0948\u0964\" class=\"wp-image-2396\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 1. \u0911\u0938\u093f\u0932\u094b\u0938\u094d\u0915\u094b\u092a \u0924\u0941\u0932\u0928\u093e: \u092e\u094b\u091f\u0930 \u0907\u0928\u0930\u0936 (\u090a\u092a\u0930) 200 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902 6\u00d7 \u092a\u0940\u0915 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948; \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 (\u0928\u0940\u091a\u0947) 1 kHz \u0915\u0947 \u0905\u0928\u0941\u0928\u093e\u0926 \u0915\u094d\u0937\u092f \u0915\u0947 \u0938\u093e\u0925 40\u00d7 \u092a\u0940\u0915 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0915\u0947 \u0932\u093f\u090f AC-6b \u0930\u0947\u091f\u0947\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"utilization-category-ac-6b-what-makes-it-different\">\u0909\u092a\u092f\u094b\u0917 \u0936\u094d\u0930\u0947\u0923\u0940 AC-6b: \u0907\u0938\u0947 \u0915\u094d\u092f\u093e \u0905\u0932\u0917 \u092c\u0928\u093e\u0924\u093e \u0939\u0948<\/h2>\n\n\n\n<p>IEC 62271-106 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u094b\u0917 \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u093e\u0901 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 AC-4 \u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u093f\u0902\u0917 (\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928, 6\u20138\u00d7 \u0907\u0928\u0930\u0936) \u0915\u094b \u0915\u0935\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.&nbsp;<strong>\u090f\u0938\u0940-6\u092c\u0940<\/strong>&nbsp;\u092f\u0939 \u0905\u092a\u0928\u0940 \u0905\u0928\u0942\u0920\u0940 \u0907\u0928\u0930\u0936 \u0914\u0930 \u0930\u093f\u0915\u0935\u0930\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u0913\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u092c\u094b\u0927\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092e\u0941\u0916\u094d\u092f AC-6b \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0915\u094d\u0937\u092e\u0924\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923<\/strong>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u094b \u092a\u0940\u0915 \u0907\u0928\u0930\u0936 (40\u2013100\u00d7 \u0930\u0947\u091f\u0947\u0921) \u0915\u0947 \u0916\u093f\u0932\u093e\u092b \u092c\u093f\u0928\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u092f\u093e \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u0947 \u092c\u0902\u0926 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n\n\n\n<li><strong>\u0915\u094d\u0937\u092e\u0924\u093e \u0924\u094b\u0921\u093c\u0928\u093e<\/strong>: \u0907\u0902\u091f\u0930\u092a\u094d\u091f \u0930\u0947\u091f\u0947\u0921 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0927\u093e\u0930\u093e \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u094b \u0905\u0935\u0936\u094d\u092f \u092c\u093e\u0927\u093f\u0924 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n\n\n\n<li><strong>\u092a\u0941\u0928\u0903 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0938\u0939\u0928 \u0915\u0930\u0947\u0902<\/strong>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0930\u0941\u0915\u093e\u0935\u091f \u0915\u0947 \u092c\u093e\u0926 \u092d\u0940 \u091a\u093e\u0930\u094d\u091c \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902; TRV (\u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u092a\u0941\u0928\u0930\u094d\u092a\u094d\u0930\u093e\u092a\u094d\u0924\u093f \u0935\u094b\u0932\u094d\u091f\u0947\u091c) \u092e\u094b\u091f\u0930 \u0932\u094b\u0921 \u0915\u0947 \u0932\u093f\u090f 2.0 p.u. \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u0938\u0915\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f \u0938\u093e\u092e\u093e\u0928\u094d\u092f\u0924\u0903 \u092f\u0939 1.4 p.u. \u0939\u094b\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p>120 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u093e \u0915\u093f \u092e\u093e\u0928\u0915 AC-4 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0905\u0938\u0902\u0917\u0924\u093f \u0915\u0947 \u0915\u093e\u0930\u0923 500\u20132,000 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 CuCr25 \u092e\u093f\u0936\u094d\u0930 \u0927\u093e\u0924\u0941 (\u0909\u091a\u094d\u091a \u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e \u0938\u093e\u092e\u0917\u094d\u0930\u0940) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 AC-6b \u0930\u0947\u091f\u0947\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0947 \u092a\u0939\u0932\u0947 10,000\u201330,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u091f\u093f\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u0902\u0924\u0930\u093e\u0932<\/strong>&nbsp;AC-6b \u0921\u093f\u091c\u093c\u093e\u0907\u0928\u094b\u0902 \u092e\u0947\u0902 \u0935\u0943\u0926\u094d\u0927\u093f: AC-4 \u0915\u0947 \u0932\u093f\u090f 8\u201310 \u092e\u093f\u092e\u0940 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 12\u201314 \u092e\u093f\u092e\u0940\u0964 \u092c\u0921\u093c\u093e \u0917\u0948\u092a \u0905\u0927\u093f\u0915 \u092a\u094d\u0930\u0940-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0926\u0942\u0930\u0940 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u0930\u094d\u0915 \u0906\u0930\u0902\u092d \u0939\u094b\u0928\u0947 \u092a\u0930 \u091a\u0930\u092e \u0927\u093e\u0930\u093e \u0918\u0928\u0924\u094d\u0935 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0917\u0924\u093f \u0915\u093e \u0924\u094d\u092f\u093e\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930\u094b\u0902 \u0915\u094b \u092e\u094b\u091f\u0930\u094d\u0938 \u0915\u0940 \u0924\u0930\u0939 \u0924\u0947\u091c\u093c \u0926\u094b\u0937 \u0928\u093f\u0935\u093e\u0930\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964.<\/p>\n\n\n\n<p><strong>AC-6b \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u092f\u0941 (IEC 62271-106 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092e\u093e\u0928)<\/strong>:<br>\u2022 12 kV, 200 A \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940:\u00a0<strong>\u0967\u0966,\u0966\u0966\u0966 \u0911\u092a\u0930\u0947\u0936\u0928<\/strong><br>\u2022 12 kV, 400 A \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940:\u00a0<strong>\u096e,\u0966\u0966\u0966 \u0911\u092a\u0930\u0947\u0936\u0928<\/strong><br>\u2022 24 kV, 200 A \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940:\u00a0<strong>6,000 \u0911\u092a\u0930\u0947\u0936\u0928<\/strong><br>AC-4 \u092e\u094b\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902: \u0938\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917 \u092a\u0930 10,000\u201315,000 \u0938\u0902\u091a\u093e\u0932\u0928\u0964.<\/p>\n\n\n\n<p>\u0915\u0940 \u0935\u094d\u092f\u093e\u092a\u0915 \u0938\u092e\u091d \u0915\u0947 \u0932\u093f\u090f&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/capacitor-duty-contactor-failure-modes-switching\/\">\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/a>, \u0921\u0940\u091f\u094d\u092f\u0942\u0928\u093f\u0902\u0917 \u0930\u093f\u090f\u0915\u094d\u091f\u0930 \u0938\u092e\u0928\u094d\u0935\u092f \u0914\u0930 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092b\u093c\u093f\u0932\u094d\u091f\u0930\u093f\u0902\u0917 \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"pre-insertion-resistors-physics-and-sizing\">\u092a\u094d\u0930\u0935\u0947\u0936-\u092a\u0942\u0930\u094d\u0935 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915: \u092d\u094c\u0924\u093f\u0915\u0940 \u0914\u0930 \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923<\/h2>\n\n\n\n<p>\u092a\u094d\u0930\u093f-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0947 \u0938\u093e\u0925 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0930\u0942\u092a \u0938\u0947 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u092e\u0947\u0902 \u091c\u0941\u0921\u093c\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0915\u094b \u092a\u094d\u0930\u092c\u0902\u0927\u0928\u0940\u092f \u0938\u094d\u0924\u0930 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964 10\u201350 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 (\u0935\u093f\u0928\u094d\u092f\u0938\u094d\u0924 \u0935\u093f\u0932\u0902\u092c) \u0915\u0947 \u092c\u093e\u0926, \u090f\u0915 \u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0935\u0939 \u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0947 \u0939\u091f \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092e\u0942\u0932 \u0938\u0930\u094d\u0915\u093f\u091f<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092e\u0941\u0916\u094d\u092f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0902\u0926 \u0939\u094b\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>R \u0926\u094d\u0935\u093e\u0930\u093e \u0938\u0940\u092e\u093f\u0924 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e: I = V \/ (Z_source + R)<\/li>\n\n\n\n<li>\u0935\u093f\u0932\u0902\u092c \u0930\u093f\u0932\u0947 10-50 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092a\u094d\u0930\u0924\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0924\u093e \u0939\u0948 (\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0932\u0917\u092d\u0917 95% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0924\u0915 \u091a\u093e\u0930\u094d\u091c \u0939\u094b\u0924\u093e \u0939\u0948)<\/li>\n\n\n\n<li>\u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0902\u0926 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0936\u0949\u0930\u094d\u091f\u093f\u0902\u0917 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930<\/li>\n\n\n\n<li>\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u092e\u0947\u0902 \u0915\u094b\u0908 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0940\u0964<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0938\u0942\u0924\u094d\u0930<\/strong>:<br>R = (V<sub>\u0936\u093f\u0916\u0930, \u091a\u0930\u092e, \u092a\u0930\u092e, \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u0909\u0924\u094d\u0924\u092e, \u0938\u0930\u094d\u0935\u094b\u091a\u094d\u091a, \u092a\u0930\u092e \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u092a\u0930<\/sub>&nbsp;\u2013 \u0935\u0940<sub>\u091f\u094b\u092a\u0940,\u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915<\/sub>) \/ \u092e\u0948\u0902<sub>\u092a\u094d\u0930\u0935\u093e\u0939,\u0905\u0927\u093f\u0915\u0924\u092e<\/sub><br>12 kV \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0932\u093f\u090f, \u0907\u0928\u0930\u0936 \u0915\u094b 2 kA \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0928\u093e:<br>R = (16,970 V \u2013 0 V) \/ 2,000 A \u2248&nbsp;<strong>8.5 \u0913\u092e<\/strong><\/p>\n\n\n\n<p><strong>\u0936\u0915\u094d\u0924\u093f \u0905\u092a\u0935\u094d\u092f\u092f (\u0905\u0932\u094d\u092a\u0915\u093e\u0932\u093f\u0915 \u0930\u0947\u091f\u093f\u0902\u0917)<\/strong>:<br>P = I\u00b2 \u00d7 R \u00d7 \u0938\u092e\u092f<br>2 kA \u0907\u0928\u0930\u0936, 20 ms \u0905\u0935\u0927\u093f \u0915\u0947 \u0932\u093f\u090f:<br>\u090a\u0930\u094d\u091c\u093e = (2,000)\u00b2 \u00d7 8.5 \u00d7 0.020 =\u00a0<strong>680 \u0915\u093f\u0932\u094b \u091c\u0942\u0932<\/strong><br>\u0909\u091a\u094d\u091a-\u090a\u0930\u094d\u091c\u093e \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 (\u0935\u093e\u092f\u0930\u0935\u093e\u0909\u0902\u0921 \u092f\u093e \u0917\u094d\u0930\u093f\u0921 \u092a\u094d\u0930\u0915\u093e\u0930) \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u092e\u0932 \u092e\u0947\u0902 \u091a\u0941\u0928\u094c\u0924\u093f\u092f\u093e\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u094b \u0925\u0930\u094d\u092e\u0932 \u0936\u0949\u0915 (\u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u2192 20 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902 300\u00b0C) \u0938\u0939\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n\n\n\n<li>\u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u094b 10-50 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0935\u093f\u0902\u0921\u094b \u0915\u0947 \u092d\u0940\u0924\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0930\u0942\u092a \u0938\u0947 \u092c\u0902\u0926 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n\n\n\n<li>\u0905\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0907\u0928\u0930\u0936 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0905\u0935\u0938\u094d\u0925\u093e \u0916\u0941\u0932\u0947 \u092a\u0930\u093f\u092a\u0925 (\u0936\u0949\u0930\u094d\u091f \u0928\u0939\u0940\u0902) \u0939\u094b\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n<\/ul>\n\n\n\n<p>\u0939\u092e\u093e\u0930\u0947 80 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902, \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0928\u0947 \u0921\u093e\u092f\u0930\u0947\u0915\u094d\u091f \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0915\u094d\u0937\u092f \u0915\u094b 60\u201370% \u0924\u0915 \u0915\u092e \u0915\u093f\u092f\u093e, \u091c\u093f\u0938\u0938\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u091c\u0940\u0935\u0928\u0915\u093e\u0932 3,000 \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 12,000+ \u0938\u0902\u091a\u093e\u0932\u0928 \u0939\u094b \u0917\u092f\u093e\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02.webp\" alt=\"\u092a\u0942\u0930\u094d\u0935-\u0938\u094d\u0925\u093e\u092a\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0930\u094d\u0915\u093f\u091f \u0906\u0930\u0947\u0916 \u091c\u093f\u0938\u092e\u0947\u0902 \u092e\u0941\u0916\u094d\u092f \u0938\u0902\u092a\u0930\u094d\u0915\u0915, \u092c\u093e\u0908\u092a\u093e\u0938 \u0938\u0902\u092a\u0930\u094d\u0915\u0915 \u0914\u0930 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u091f\u093f\u092a\u094d\u092a\u0923\u093f\u092f\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0926\u093f\u0916\u093e\u090f \u0917\u090f \u0939\u0948\u0902\u0964\" class=\"wp-image-2395\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 2. \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0938\u0930\u094d\u0915\u093f\u091f \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0915\u094b 34 kA (\u0938\u0940\u0927\u0947 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917) \u0938\u0947 \u0918\u091f\u093e\u0915\u0930 2 kA (\u0938\u0940\u092e\u093f\u0924) \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u092e\u0941\u0916\u094d\u092f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 8.5 \u03a9 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u0947 \u0938\u093e\u0925 \u092c\u0902\u0926 \u0939\u094b\u0924\u093e \u0939\u0948; 20 ms \u0915\u0940 \u0926\u0947\u0930\u0940 \u0915\u0947 \u092c\u093e\u0926 \u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"back-to-back-switching-and-resonance-risk\">\u0932\u0917\u093e\u0924\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0914\u0930 \u0905\u0928\u0941\u0928\u093e\u0926 \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/h2>\n\n\n\n<p>\u091c\u092c \u0915\u0908 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u090f\u0915 \u0939\u0940 \u092c\u0938 \u092a\u0930 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u090f\u0915 \u092c\u0948\u0902\u0915 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u0947 \u092a\u0930 \u091c\u092c\u0915\u093f \u0905\u0928\u094d\u092f \u0938\u0915\u094d\u0930\u093f\u092f \u0930\u0939\u0924\u0947 \u0939\u0948\u0902, \u201c\u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915\u201d \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 \u0938\u0915\u094d\u0930\u093f\u092f \u092c\u0948\u0902\u0915 \u090f\u0915 \u0928\u093f\u092e\u094d\u0928 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0935\u093e\u0932\u0947 \u090f\u0938\u0940 \u0938\u094d\u0930\u094b\u0924 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0928\u090f \u092c\u0902\u0926 \u0915\u093f\u090f \u0917\u090f \u092c\u0948\u0902\u0915 \u092e\u0947\u0902 \u092d\u093e\u0930\u0940 \u0907\u0928\u0930\u0936 \u092a\u094d\u0930\u0935\u093e\u0939 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u090f\u0915 \u0915\u0947 \u092c\u093e\u0926 \u090f\u0915 \u0907\u0928\u0930\u0936 \u0915\u0940 \u0917\u0902\u092d\u0940\u0930\u0924\u093e<\/strong>:<br>3 \u092e\u094c\u091c\u0942\u0926\u093e \u092c\u0948\u0902\u0915\u094b\u0902 (\u0915\u0941\u0932 15 MVAR) \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u092a\u0930, \u091a\u094c\u0925\u0947 \u092c\u0948\u0902\u0915 (5 MVAR) \u0915\u094b \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u092a\u0930 \u0907\u0928\u0930\u0936 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948:<br>Z<sub>\u092a\u094d\u0930\u092d\u093e\u0935\u0940<\/sub>\u00a0\u0915\u0947\u0935\u0932 = (\u0915\u0947\u092c\u0932 \u0907\u0902\u0921\u0915\u094d\u091f\u0947\u0902\u0938) \u2014 \u092e\u094c\u091c\u0942\u0926\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<br>\u092a\u0930\u093f\u0923\u093e\u092e: \u0907\u0928\u0930\u0936 \u092a\u0939\u0941\u0901\u091a \u0938\u0915\u0924\u093e \u0939\u0948\u00a0<strong>100-200\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e<\/strong>\u00a0\u092a\u0939\u0932\u0947 \u092c\u0948\u0902\u0915 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f 20-40\u00d7 \u092c\u0928\u093e\u092e\u0964.<\/p>\n\n\n\n<p><strong>\u0928\u093f\u0935\u093e\u0930\u0923 \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0935\u093f\u0932\u0902\u092c \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u0930\u092e\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917<\/strong>30\u201360 \u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u0947 \u0938\u093e\u0925 \u090f\u0915-\u090f\u0915 \u0915\u0930\u0915\u0947 \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u094b \u090a\u0930\u094d\u091c\u093e\u0935\u093e\u0928 \u0915\u0930\u0947\u0902, \u0924\u093e\u0915\u093f \u0915\u094d\u0937\u0923\u093f\u0915 \u0938\u0902\u0915\u0947\u0924 \u0915\u094d\u0937\u0940\u0923 \u0939\u094b \u0938\u0915\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0915\u094b\u0902 \u0915\u093e \u0935\u093f\u0938\u0902\u0927\u093e\u0928<\/strong>\u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u092a\u094d\u0930\u0947\u0930\u0915\u0924\u093e (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 5-7%) \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0915\u094b \u092c\u0922\u093c\u093e\u0915\u0930 \u0905\u091a\u093e\u0928\u0915 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094b \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li><strong>\u0938\u092e\u0915\u093e\u0932\u093f\u0915 \u0938\u092e\u093e\u092a\u0928<\/strong>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u0905\u0902\u0924\u0930 \u0915\u094b \u0915\u092e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u0936\u0942\u0928\u094d\u092f-\u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 \u092a\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0902\u0926 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p>40 \u092c\u0939\u0941-\u092c\u0948\u0902\u0915 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u093e \u0915\u093f \u0921\u0940\u091f\u094d\u092f\u0942\u0928\u093f\u0902\u0917 \u0930\u093f\u090f\u0915\u094d\u091f\u0930\u094b\u0902 \u0928\u0947 \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0907\u0928\u0930\u0936 \u0915\u094b 50\u201370% (150\u00d7 \u0938\u0947 45\u201360\u00d7) \u0924\u0915 \u0915\u092e \u0915\u0930 \u0926\u093f\u092f\u093e, \u091c\u094b \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 PFC \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b \u092c\u0922\u093c\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0905\u0928\u0941\u0928\u093e\u0926<\/strong>&nbsp;\u091c\u092c \u0930\u093f\u0910\u0915\u094d\u091f\u0930 L \u0914\u0930 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 C \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0917\u094d\u0930\u093f\u0921 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0906\u0935\u0943\u0924\u094d\u0924\u093f\u092f\u094b\u0902 (5\u0935\u0940\u0902, 7\u0935\u0940\u0902, 11\u0935\u0940\u0902) \u0915\u0947 \u092a\u093e\u0938 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u0905\u0928\u0941\u0928\u093e\u0926 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948, \u0924\u092c \u091c\u094b\u0916\u093f\u092e \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0909\u091a\u093f\u0924 \u0930\u093f\u0910\u0915\u094d\u091f\u0930 \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0905\u0927\u094d\u092f\u092f\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>5.67% \u0930\u093f\u090f\u0915\u094d\u091f\u0930 4.2\u00d7 \u092e\u0942\u0932 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u092a\u0930 \u0905\u0928\u0941\u0928\u093e\u0926 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 (4\u0920\u0947 \u0914\u0930 5\u0935\u0947 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0915\u0947 \u092c\u0940\u091a)<\/li>\n\n\n\n<li>7% \u0930\u093f\u090f\u0915\u094d\u091f\u0930 3.8 \u0917\u0941\u0928\u093e \u092e\u0942\u0932 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u092a\u0930 \u0905\u0928\u0941\u0928\u093e\u0926 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 (5\u0935\u0947\u0902 \u0938\u0947 \u0928\u0940\u091a\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092e\u093e\u0930\u094d\u091c\u093f\u0928)<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03.webp\" alt=\"\u090f\u0915 \u0915\u0947 \u092c\u093e\u0926 \u090f\u0915 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u0947\u0915\u094d\u091f\u0930 \u0906\u0930\u0947\u0916 \u091c\u094b \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u092c\u0948\u0902\u0915 40\u00d7 \u0938\u0947 200\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0924\u0915 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0915\u094b \u0915\u0948\u0938\u0947 \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964\" class=\"wp-image-2394\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 3. \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u092a\u0930\u093f\u0926\u0943\u0936\u094d\u092f: \u090a\u0930\u094d\u091c\u093e\u092f\u0941\u0915\u094d\u0924 \u092c\u0948\u0902\u0915 (15 MVAR) \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0915\u094b 0.5\u03a9 \u0938\u0947 \u0918\u091f\u093e\u0915\u0930 \u0915\u0947\u0935\u0932 \u0915\u0947\u092c\u0932 \u0907\u0902\u0921\u0915\u094d\u091f\u0947\u0902\u0938 (0.02\u03a9) \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0915\u0947 40\u00d7 \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 200\u00d7 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-coordination-fuses-vs-relays\">\u0938\u0902\u0930\u0915\u094d\u0937\u0923 \u0938\u092e\u0928\u094d\u0935\u092f: \u092b\u094d\u092f\u0942\u091c \u092c\u0928\u093e\u092e \u0930\u093f\u0932\u0947<\/h2>\n\n\n\n<p>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094b \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0947 \u092c\u0940\u091a \u0905\u0902\u0924\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0907\u0928\u0930\u0936 \u0915\u094d\u0937\u0923\u093f\u0915<\/strong>\u00a0(20-100\u00d7 \u0930\u0947\u091f\u0947\u0921, 5-20 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0905\u0935\u0927\u093f) \u2014 \u091f\u094d\u0930\u093f\u092a \u0928 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li><strong>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u094b\u0937<\/strong>\u00a0(\u092b\u091f\u0928\u093e, \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0905\u092a\u091a\u092f\u0928) \u2014 \u0924\u0941\u0930\u0902\u0924 \u091f\u094d\u0930\u093f\u092a \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li><strong>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901<\/strong>\u00a0(\u0935\u0947\u0932\u094d\u0921\u0947\u0921 \u0938\u0902\u092a\u0930\u094d\u0915, \u0916\u0941\u0932\u093e \u0905\u091f\u0915\u093e) \u2014 \u0905\u0932\u093e\u0930\u094d\u092e\/\u091f\u094d\u0930\u093f\u092a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092b\u094d\u092f\u0942\u091c \u0938\u092e\u0928\u094d\u0935\u092f<\/strong>&nbsp;(5 MVAR \u0938\u0947 \u0915\u092e \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u092e\u093e\u0928\u094d\u092f):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0940 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0915\u093e 1.5\u20132.0 \u0917\u0941\u0928\u093e \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f-\u0932\u093f\u092e\u093f\u091f\u093f\u0902\u0917 \u092b\u094d\u092f\u0942\u091c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092b\u094d\u092f\u0942\u091c I\u00b2t \u0915\u094b \u0907\u0928\u0930\u0936 \u090a\u0930\u094d\u091c\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f:\n<ul class=\"wp-block-list\">\n<li>\u0907\u0928\u0930\u0936 I\u00b2t = (40 \u00d7 I_rated)\u00b2 \u00d7 0.010 s<\/li>\n\n\n\n<li>200 A \u0915\u0947 \u090f\u0915 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0947 \u0932\u093f\u090f: I\u00b2t = 64,000 A\u00b2s<\/li>\n\n\n\n<li>\u091d\u0942\u0920\u0940 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f I\u00b2t &gt;100,000 A\u00b2s \u0935\u093e\u0932\u093e \u092b\u094d\u092f\u0942\u091c \u091a\u0941\u0928\u0947\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0930\u093f\u0932\u0947 \u0938\u092e\u0928\u094d\u0935\u092f<\/strong>&nbsp;(&gt;5 MVAR \u092f\u093e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0938\u0947 \u092a\u093e\u0930 \u092a\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0936\u094d\u091a\u093f\u0924-\u0938\u092e\u092f \u0935\u093f\u0932\u0902\u092c (0.5\u20131.0 \u0938\u0947\u0915\u0902\u0921) \u0935\u093e\u0932\u0940 \u0913\u0935\u0930\u0915\u0930\u0902\u091f \u0930\u093f\u0932\u0947 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092a\u093f\u0915\u0905\u092a \u0915\u094b 1.3\u20131.5\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f \u092a\u0930 \u0938\u0947\u091f \u0915\u0930\u0947\u0902 (\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938 \u0914\u0930 \u091f\u0949\u0932\u0930\u0947\u0902\u0938 \u0915\u094b \u0927\u094d\u092f\u093e\u0928 \u092e\u0947\u0902 \u0930\u0916\u0924\u0947 \u0939\u0941\u090f)<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u0909\u092a\u0932\u092c\u094d\u0927 \u0939\u094b \u0924\u094b \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 (\u0926\u0942\u0938\u0930\u0940\/\u0924\u0940\u0938\u0930\u0940 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927) \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p>\u0939\u092e\u0928\u0947 \u0916\u0928\u0928 \u0938\u094d\u0925\u0932\u094b\u0902 \u092a\u0930 15\u201320 \u090f\u092e\u0935\u094d\u0939\u093e\u0930 \u0915\u0947 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u0947 4\u20136 \u092c\u093e\u0930\/\u0918\u0902\u091f\u093e \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915-\u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u0930\u093f\u0932\u0947 \u0915\u0940 \u0938\u093e\u0927\u093e\u0930\u0923 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c \u0915\u0947 \u0938\u093e\u0925 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u091f\u094d\u0930\u093f\u092a\u094b\u0902 \u092e\u0947\u0902 30% \u0915\u0940 \u0915\u092e\u0940 \u092e\u093e\u092a\u0940\u0964.<\/p>\n\n\n\n<p><strong>\u0930\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0909\u0926\u093e\u0939\u0930\u0923 (SEL-751 \u092b\u0940\u0921\u0930 \u0930\u093f\u0932\u0947, 12 kV 5 MVAR \u092c\u0948\u0902\u0915, 240 A \u0930\u0947\u091f\u0947\u0921)<\/strong>:<br><code>50P1 = \u092c\u0902\u0926<\/code>\u00a0(\u0924\u0924\u094d\u0915\u093e\u0932 \u0905\u0915\u094d\u0937\u092e \u0915\u0930\u0947\u0902)<br><code>51P1 = 1.4 \u00d7 240 = 336 A<\/code>\u00a0(\u0909\u0920\u093e\u0928\u093e)<br><code>51TD1 = 1.0 s<\/code>\u00a0(\u092d\u0940\u0921\u093c \u091b\u0902\u091f\u0928\u0947 \u092e\u0947\u0902 \u0932\u0917\u0928\u0947 \u0935\u093e\u0932\u093e \u0938\u092e\u092f)<br><code>50H1 = 20%<\/code>\u00a0(\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u0925\u094d\u0930\u0947\u0936\u094b\u0932\u094d\u0921)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contactor-selection-checklist-for-capacitor-duty\">\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0932\u093f\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u091a\u092f\u0928 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/h2>\n\n\n\n<p>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0938\u094d\u092a\u0937\u094d\u091f AC-6b \u0930\u0947\u091f\u093f\u0902\u0917 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u2014\u092e\u093e\u0928\u0915 AC-4 \u092e\u094b\u091f\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u092e\u092f \u0938\u0947 \u092a\u0939\u0932\u0947 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u090f\u0902\u0917\u0947\u0964 \u0907\u0938 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<p><strong>1. AC-6b \u092a\u094d\u0930\u092e\u093e\u0923\u0928 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0926\u093f\u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u093e IEC 62271-106 \u092a\u094d\u0930\u0915\u093e\u0930-\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u0905\u0928\u0941\u0930\u094b\u0927 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0927\u093e\u0930\u093e \u0915\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 (12 kV, 400 A, \u0906\u0926\u093f) \u0938\u0947 \u092e\u0947\u0932 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091c\u0940\u0935\u0928 \u0930\u0947\u091f\u093f\u0902\u0917 \u091c\u093e\u0901\u091a\u0947\u0902: \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 PFC \u0915\u0947 \u0932\u093f\u090f \u0928\u094d\u092f\u0942\u0928\u0924\u092e 8,000 \u0938\u0902\u091a\u093e\u0932\u0928<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u0938\u094d\u0925\u093f\u0930-\u0905\u0935\u0938\u094d\u0925\u093e \u0927\u093e\u0930\u093e \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0947\u0902<\/strong><br>I<sub>\u0915ondensator<\/sub>\u00a0= \u092a\u094d\u0930\u0936\u094d\u0928<sub>\u090f\u092e\u0935\u0940\u090f\u0906\u0930<\/sub>\u00a0\/ (\u221a3 \u00d7 V<sub>\u092a\u0902\u0915\u094d\u0924\u093f-\u0926\u0930-\u092a\u0902\u0915\u094d\u0924\u093f<\/sub>)<br>\u0909\u0926\u093e\u0939\u0930\u0923: 12 kV \u092a\u0930 5 MVAR<br>I = 5,000,000 \/ (1.732 \u00d7 12,000) =\u00a0<strong>240 \u090f<\/strong><br>\u091a\u0941\u0928\u0940 \u0917\u0908 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0940 \u0930\u0947\u091f\u093f\u0902\u0917 \u22651.35\u00d7 \u0917\u0923\u0928\u093e \u0915\u0940 \u0917\u0908 \u0927\u093e\u0930\u093e =\u00a0<strong>325 \u090f\u0915 \u0928\u094d\u092f\u0942\u0928\u0924\u092e<\/strong><\/p>\n\n\n\n<p><strong>3. \u0907\u0928\u0930\u0936 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u094d\u0937\u092e\u0924\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>AC-6b \u0915\u0947 \u0932\u093f\u090f \u092a\u0940\u0915 \u092e\u0947\u0915\u093f\u0902\u0917 \u0915\u0930\u0902\u091f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0921\u0947\u091f\u093e\u0936\u0940\u091f \u092e\u0947\u0902 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n\n\n\n<li>\u0938\u093e\u092e\u093e\u0928\u094d\u092f AC-6b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 40\u201360\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0907\u0928\u0930\u0936 \u0915\u094b \u0938\u0902\u092d\u093e\u0932\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0917\u0902\u092d\u0940\u0930 \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 (&gt;60\u00d7 \u0907\u0928\u0930\u0936) \u0915\u0947 \u0932\u093f\u090f, \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>4. \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 NO\/NC \u0938\u0902\u092a\u0930\u094d\u0915 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0928\u094d\u092f\u0942\u0928\u0924\u092e 4 NO + 2 NC)<\/li>\n\n\n\n<li>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u0935\u094b\u0932\u094d\u091f\u0947\u091c (110 VDC, 220 VAC, \u0906\u0926\u093f) \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921<\/li>\n\n\n\n<li>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0940 \u091c\u0940\u0935\u0928 \u0905\u0935\u0927\u093f: 100,000\u2013300,000 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928<\/li>\n<\/ul>\n\n\n\n<p><strong>5. \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0930\u0947\u091f\u093f\u0902\u0917<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0907\u0928\u0921\u094b\u0930: \u0928\u094d\u092f\u0942\u0928\u0924\u092e IP20; \u0906\u0909\u091f\u0921\u094b\u0930: \u0928\u094d\u092f\u0942\u0928\u0924\u092e IP54<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u090a\u0901\u091a\u093e\u0908 1000 \u092e\u0940\u091f\u0930 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u0924\u094b \u090a\u0901\u091a\u093e\u0908 \u0938\u0941\u0927\u093e\u0930 (\u0915\u094d\u0932\u093f\u092f\u0930\u0947\u0902\u0938 \u092c\u0922\u093c\u093e\u0928\u093e \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0939\u0948)<\/li>\n\n\n\n<li>\u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u0940\u092e\u093e: -25\u00b0C \u0938\u0947 +40\u00b0C \u0938\u093e\u092e\u093e\u0928\u094d\u092f, \u091a\u0930\u092e \u091c\u0932\u0935\u093e\u092f\u0941 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0938\u094d\u0924\u093e\u0930\u093f\u0924 \u0938\u0940\u092e\u093e<\/li>\n<\/ul>\n\n\n\n<p>\u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u092a\u0930\u093e\u092e\u0930\u094d\u0936 \u0915\u0930\u0947\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0914\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/a>&nbsp;AC-6b \u0921\u094d\u092f\u0942\u091f\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u0915\u0935\u0930 \u0915\u0930\u0924\u0947 \u0939\u0941\u090f, \u0914\u0930 \u0907\u0938 \u0938\u0947 \u090f\u092a\u094d\u0932\u093f\u0915\u0947\u0936\u0928 \u0938\u093e\u0907\u091c\u093c\u093f\u0902\u0917 \u0915\u0940 \u0915\u094d\u0930\u0949\u0938-\u091a\u0947\u0915 \u0915\u0930\u0947\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/medium-voltage-vacuum-contactor-guide\/\">\u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0902\u092a\u0930\u094d\u0915\u093f\u0924\u094d\u0930 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04.webp\" alt=\"\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u091a\u092f\u0928 \u092b\u094d\u0932\u094b\u091a\u093e\u0930\u094d\u091f, \u091c\u093f\u0938\u092e\u0947\u0902 AC-6b \u0930\u0947\u091f\u093f\u0902\u0917, \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0930, \u0914\u0930 \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0928\u093f\u0930\u094d\u0923\u092f \u0926\u093f\u0916\u093e\u090f \u0917\u090f \u0939\u0948\u0902\u0964\" class=\"wp-image-2393\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 4. AC-6b \u0921\u094d\u092f\u0942\u091f\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u0902\u091a\u093e\u0932\u0928, \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0930 \u0915\u0940 \u0906\u0930\u094d\u0925\u093f\u0915\u0924\u093e \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u0940\u0935\u0928 \u0915\u0947 \u0938\u092e\u091d\u094c\u0924\u094b\u0902 \u0915\u094b \u0938\u0902\u092c\u094b\u0927\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u091a\u092f\u0928 \u092b\u094d\u0932\u094b\u091a\u093e\u0930\u094d\u091f\u0964.<\/figcaption><\/figure>\n\n\n\n<p><strong>\u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u0926\u0930\u094d\u092d:<\/strong> \u090f\u0938\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0921\u094d\u092f\u0942\u091f\u0940 \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u093e\u0901 \u0914\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u092e\u0947\u0902 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0915\u0940 \u0917\u0908 \u0939\u0948\u0902\u0964&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">\u0906\u0908\u0908\u0938\u0940 62271-106<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-and-end-of-life-indicators\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0914\u0930 \u091c\u0940\u0935\u0928-\u0905\u0902\u0924 \u0938\u0902\u0915\u0947\u0924\u0915<\/h2>\n\n\n\n<p>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930-\u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0909\u091a\u094d\u091a \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0915\u0947 \u0915\u093e\u0930\u0923 \u092e\u094b\u091f\u0930-\u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u092e\u0915\u0915\u094d\u0937\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947 \u0918\u093f\u0938\u0924\u0947 \u0939\u0948\u0902\u0964 \u0907\u0928 \u0938\u0902\u0915\u0947\u0924\u0915\u094b\u0902 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<p><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0939\u0930 2,000\u20133,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0947\u0902 (AC-4 \u0915\u0947 \u0932\u093f\u090f 5,000 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902)<\/li>\n\n\n\n<li>\u091c\u092c \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 500 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u091c\u093e\u090f \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u092c\u0926\u0932\u0947\u0902 (\u0928\u090f \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 100\u2013200 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e \u0939\u094b\u0924\u093e \u0939\u0948)\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0932\u094d\u0921 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u0947 \u092c\u093e\u0926, \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0916\u0941\u0932 \u091c\u093e\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u0915\u0949\u0907\u0932 \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0939\u094b\u0928\u0947 \u092a\u0930 \u092e\u0941\u0916\u094d\u092f \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0902\u0926 \u0930\u0939\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0905\u0932\u093e\u0930\u094d\u092e \u0915\u0947 \u0932\u093f\u090f \u0938\u0939\u093e\u092f\u0915 \u0938\u094d\u0935\u093f\u091a \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u094d\u0925\u093f\u0930-\u0905\u0935\u0938\u094d\u0925\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0927\u093e\u0930\u093e \u092e\u093e\u092a\u0947\u0902<\/li>\n\n\n\n<li>\u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0938\u0947 &gt;10% \u0915\u0940 \u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u092f\u093e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0905\u0928\u0941\u0928\u093e\u0926 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p>\u0939\u092e\u093e\u0930\u0947 5-\u0935\u0930\u094d\u0937\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0905\u0927\u094d\u092f\u092f\u0928 \u092e\u0947\u0902 200 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902, \u0938\u0939\u0940 \u0930\u0947\u091f\u0947\u0921 AC-6b \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0928\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0947 \u092a\u0939\u0932\u0947 12,000\u201318,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0939\u093e\u0938\u093f\u0932 \u0915\u093f\u090f, \u091c\u092c\u0915\u093f \u0917\u0932\u0924 \u0924\u0930\u0940\u0915\u0947 \u0938\u0947 \u0932\u093e\u0917\u0942 \u0915\u093f\u090f \u0917\u090f AC-4 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0928\u0947 3,000\u20135,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0939\u0940 \u0926\u093f\u090f\u0964 \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0928\u0947 \u0917\u0902\u092d\u0940\u0930 \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u094b 20,000+ \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u092c\u0922\u093c\u093e \u0926\u093f\u092f\u093e\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937<\/h2>\n\n\n\n<p>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0935\u093f\u0936\u0947\u0937 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u092e\u093e\u0928\u0915 \u092e\u094b\u091f\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 20\u2013100 \u0917\u0941\u0928\u093e \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e\u0913\u0902 \u0914\u0930 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u090f\u0902\u091f\u094d\u0938 \u0915\u0947 \u0924\u0939\u0924 \u0938\u092e\u092f\u092a\u0942\u0930\u094d\u0935 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 AC-6b \u0930\u0947\u091f\u0947\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930, \u091c\u094b \u0909\u0928\u094d\u0928\u0924 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0914\u0930 \u092c\u0922\u093c\u0947 \u0939\u0941\u090f \u092a\u094d\u0930\u0940-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0917\u0948\u092a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091c\u0940\u0935\u0928 \u0915\u094b 8,000\u201315,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u092c\u0922\u093c\u093e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0915\u0947\u0935\u0932 \u0924\u092c \u091c\u092c \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0907\u0928\u0930\u0936 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092a\u094d\u0930\u093f-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 60\u00d7 \u0938\u0947 \u0905\u0927\u093f\u0915 \u092a\u0940\u0915 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0907\u0928\u0930\u0936 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u092e\u0932\u094d\u091f\u0940-\u092c\u0948\u0902\u0915 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u092e\u0947\u0902\u0964 \u0921\u093f\u091f\u094d\u092f\u0942\u0928\u093f\u0902\u0917 \u0930\u093f\u090f\u0915\u094d\u091f\u0930\u094d\u0938 \u0926\u094b\u0939\u0930\u093e \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902: \u0907\u0928\u0930\u0936 \u0938\u0940\u092e\u093e\u0902\u0915\u0928 \u0914\u0930 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0905\u0928\u0941\u0928\u093e\u0926 \u0930\u094b\u0915\u0925\u093e\u092e, \u0939\u093e\u0932\u093e\u0902\u0915\u093f \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948 \u0924\u093e\u0915\u093f \u0928\u090f \u0905\u0928\u0941\u0928\u093e\u0926 \u092c\u093f\u0902\u0926\u0941 \u0928 \u092c\u0928\u0947\u0902\u0964.<\/p>\n\n\n\n<p>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932\u0924\u093e \u0914\u0930 \u0907\u0928\u0930\u0936 \u0905\u0938\u094d\u0925\u093f\u0930\u0924\u093e\u0913\u0902 \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u092a\u094d\u0930\u0924\u093f\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u092c\u0940\u091a \u0938\u0902\u0924\u0941\u0932\u0928 \u092c\u0928\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0913\u0935\u0930\u0915\u0930\u0902\u091f, \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u0915\u0947 \u0938\u093e\u0925, \u092a\u094d\u0930\u0924\u093f \u0918\u0902\u091f\u0947 4\u20136 \u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u092a\u093e\u0935\u0930 \u092b\u0948\u0915\u094d\u091f\u0930 \u0938\u0941\u0927\u093e\u0930 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u092c\u0938\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u092e\u093e\u0927\u093e\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0915\u0947\u0935\u0932 \u092b\u094d\u092f\u0942\u091c \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0930\u0932 \u090f\u0915\u0932-\u092c\u0948\u0902\u0915 \u092e\u0948\u0928\u0941\u0905\u0932 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u092f\u0939 \u091d\u0942\u0920\u0940 \u0938\u0902\u091a\u093e\u0932\u0928 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u0939\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u091a\u092f\u0928, \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0928\u0941\u0938\u093e\u0930 \u092a\u0942\u0930\u094d\u0935-\u0938\u094d\u0925\u093e\u092a\u0928, \u0914\u0930 \u0938\u092e\u0928\u094d\u0935\u093f\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b \u090f\u0915 \u0926\u0940\u0930\u094d\u0918\u0915\u093e\u0932\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u092e\u0938\u094d\u092f\u093e \u0938\u0947 \u090f\u0915 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u092e\u0947\u0902 \u092c\u0926\u0932 \u0926\u0947\u0924\u0940 \u0939\u0948\u2014\u092f\u0939 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0936\u0940\u0932 \u0936\u0915\u094d\u0924\u093f \u0915\u0940 \u0932\u093e\u0917\u0924 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u093e\u0925 \u0939\u0940 \u0909\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917, \u0915\u094d\u0937\u0930\u0923, \u0914\u0930 \u0938\u092e\u092f\u092a\u0942\u0930\u094d\u0935 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u093e\u0924\u0940 \u0939\u0948 \u091c\u094b \u0917\u0932\u0924 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u093f\u0924 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-capacitor-bank-switching\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928: \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917<\/h2>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 1: \u092e\u0948\u0902 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u0928\u0915 AC-4 \u092e\u094b\u091f\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u094d\u092f\u094b\u0902 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u093e?<\/strong><\/p>\n\n\n\n<p>\u092e\u094b\u091f\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 (AC-4) \u0915\u094b \u092e\u0942\u0932 \u0906\u0935\u0943\u0924\u094d\u0924\u093f (50\/60 Hz) \u092a\u0930 6\u20138\u00d7 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0918\u091f\u0915\u094b\u0902 (500 Hz \u2013 5 kHz) \u0915\u0947 \u0938\u093e\u0925 \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f \u0915\u093e 20\u2013100\u00d7 \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u0924\u093e \u0939\u0948, \u091c\u094b \u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b AC-4 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902 \u0915\u0940 \u0924\u093e\u092a\u0940\u092f \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u094b \u092a\u093e\u0930 \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u092e\u0948\u0926\u093e\u0928\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0926\u093f\u0916\u093e\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f AC-4 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 500-2,000 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092c\u093e\u0926 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f AC-6b \u0930\u0947\u091f\u0947\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 8,000-15,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u091a\u0932\u0924\u0947 \u0939\u0948\u0902\u0964 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0924\u0930\u0940\u0915\u093e \u0924\u094d\u0935\u0930\u093f\u0924 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0915\u094d\u0937\u0930\u0923 \u0914\u0930 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 \u0939\u0948\u2014AC-4 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u094d\u0938 \u092e\u0947\u0902 \u0915\u092e \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u0915\u0942\u0932\u093f\u0924 CuCr15-20 \u092e\u093f\u0936\u094d\u0930 \u0927\u093e\u0924\u0941 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0939\u094b\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f AC-6b \u092e\u0947\u0902 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0917\u0902\u092d\u0940\u0930 \u0915\u094d\u0937\u0923\u093f\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u094d\u091a \u0915\u094d\u0930\u094b\u092e\u093f\u092f\u092e \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0935\u093e\u0932\u093e CuCr25 \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 2: \u092e\u0948\u0902 \u0906\u0935\u0936\u094d\u092f\u0915 \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u092e\u093e\u0928 \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0948\u0938\u0947 \u0915\u0930\u0942\u0901?<\/strong><\/p>\n\n\n\n<p>R = V_peak \/ I_inrush_max \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902, \u091c\u0939\u093e\u0901 V_peak = \u0938\u093f\u0938\u094d\u091f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u00d7 \u221a2 (12 kV \u0915\u0947 \u0932\u093f\u090f: 16,970 V) \u0914\u0930 I_inrush_max \u0906\u092a\u0915\u0940 \u0932\u0915\u094d\u0937\u093f\u0924 \u0938\u0940\u092e\u093e \u0939\u0948 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 1.5-2.5 kA)\u0964 \u0909\u0926\u093e\u0939\u0930\u0923: 12 kV \u0915\u0947 \u0907\u0928\u0930\u0936 \u0915\u094b 2 kA \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f R = 16,970 \/ 2,000 \u2248 8.5 \u03a9\u0964 \u092a\u093e\u0935\u0930 \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u094b \u0936\u0949\u0930\u094d\u091f-\u091f\u093e\u0907\u092e \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u092d\u093e\u0932\u0928\u0940 \u091a\u093e\u0939\u093f\u090f: E = I\u00b2 \u00d7 R \u00d7 \u0938\u092e\u092f\u0964 2 kA, 20 ms \u0915\u0947 \u0932\u093f\u090f: E = (2,000)\u00b2 \u00d7 8.5 \u00d7 0.020 = 680 kJ\u0964 \u0925\u0930\u094d\u092e\u0932 \u0936\u0949\u0915 (\u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u2192 300\u00b0C \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902) \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921 \u0935\u093e\u092f\u0930\u0935\u093e\u0909\u0902\u0921 \u092f\u093e \u0917\u094d\u0930\u093f\u0921 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0947\u0902\u0964 \u0905\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0907\u0928\u0930\u0936 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u0913\u0935\u0930\u0939\u0940\u091f \u0939\u094b\u0928\u0947 \u092a\u0930 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0930 \u0915\u094b \u0913\u092a\u0928-\u0938\u0930\u094d\u0915\u093f\u091f \u092e\u0947\u0902 \u092b\u0947\u0932 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n\n\n\n<p><strong>Q3: \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u093e \u0915\u094d\u092f\u093e \u0915\u093e\u0930\u0923 \u0939\u0948 \u0914\u0930 \u092f\u0939 \u0905\u0927\u093f\u0915 \u0917\u0902\u092d\u0940\u0930 \u0915\u094d\u092f\u094b\u0902 \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0924\u092c \u0939\u094b\u0924\u0940 \u0939\u0948 \u091c\u092c \u090f\u0915 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u092c\u0902\u0926 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u091c\u092c\u0915\u093f \u0909\u0938\u0940 \u092c\u0938 \u092a\u0930 \u0905\u0928\u094d\u092f \u092c\u0948\u0902\u0915 \u090a\u0930\u094d\u091c\u093e-\u092f\u0941\u0915\u094d\u0924 \u0930\u0939\u0924\u0947 \u0939\u0948\u0902\u0964 \u090a\u0930\u094d\u091c\u093e-\u092f\u0941\u0915\u094d\u0924 \u092c\u0948\u0902\u0915 \u090f\u0915 \u0928\u093f\u092e\u094d\u0928-\u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u090f\u0938\u0940 \u0938\u094d\u0930\u094b\u0924 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u094d\u0930\u094b\u0924 \u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u0915\u094b \u092c\u093e\u092f\u092a\u093e\u0938 \u0915\u0930\u0915\u0947 \u0928\u0935-\u092c\u0902\u0926 \u092c\u0948\u0902\u0915 \u092e\u0947\u0902 100\u2013200\u00d7 \u0907\u0928\u0930\u0936 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 (\u091c\u092c\u0915\u093f \u092a\u0939\u0932\u0947 \u092c\u0948\u0902\u0915 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e-\u092f\u0941\u0915\u094d\u0924 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092f\u0939 20\u201340\u00d7 \u0939\u094b\u0924\u093e \u0939\u0948)\u0964 \u092f\u0939 \u0907\u0938\u0932\u093f\u090f \u0939\u094b\u0924\u093e \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0915\u0947\u0935\u0932 \u0915\u0947\u092c\u0932 \u0915\u0940 \u0907\u0902\u0921\u0915\u094d\u091f\u0947\u0902\u0938 \u0907\u0928\u0930\u0936 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u2014\u092e\u094c\u091c\u0942\u0926\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0930\u0942\u092a \u0938\u0947 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964   \u0928\u093f\u0935\u093e\u0930\u0923: 30\u201360 \u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0926\u0947\u0930\u0940 \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u0930\u092e\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917, 5\u20137% \u0921\u0940\u091f\u094d\u092f\u0942\u0928\u093f\u0902\u0917 \u0930\u093f\u090f\u0915\u094d\u091f\u0930 (\u0907\u0928\u0930\u0936 \u0915\u094b 50\u201370% \u0924\u0915 \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902), \u092f\u093e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u0940\u0930\u094b-\u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 \u092a\u0930 \u0938\u092e\u0915\u093e\u0932\u093f\u0915 \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917\u0964.<\/p>\n\n\n\n<p><strong>Q4: \u092e\u0948\u0902 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u091f\u094d\u0930\u093f\u092a \u0938\u0947 \u092c\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0948\u0938\u0947 \u0915\u0930\u0942\u0901?<\/strong><\/p>\n\n\n\n<p>\u0907\u0928\u0930\u0936 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0905\u0935\u0927\u093f (5\u201320 ms) \u0938\u0947 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0913\u0935\u0930\u0915\u0930\u0902\u091f (0.5\u20131.0 s \u0935\u093f\u0932\u0902\u092c) \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u092b\u094d\u092f\u0942\u091c \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f: \u091d\u0942\u0920\u0940 \u092b\u094d\u092f\u0942\u091c \u0909\u0921\u093c\u093e\u0928 \u0938\u0947 \u092c\u091a\u0928\u0947 \u0939\u0947\u0924\u0941 \u0907\u0928\u0930\u0936 I\u00b2t \u0915\u093e 2\u00d7 \u0938\u0947 \u0905\u0927\u093f\u0915 I\u00b2t \u0930\u0947\u091f\u093f\u0902\u0917 \u091a\u0941\u0928\u0947\u0902\u0964 \u0909\u0926\u093e\u0939\u0930\u0923: 200 A \u0915\u093e \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930, 40\u00d7 \u0907\u0928\u0930\u0936 (8 kA \u092a\u0940\u0915, 10 ms) \u0915\u0947 \u0938\u093e\u0925 I\u00b2t = 640,000 A\u00b2s; I\u00b2t &gt;1,200,000 A\u00b2s \u0935\u093e\u0932\u093e \u092b\u094d\u092f\u0942\u091c \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964 \u0930\u093f\u0932\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f: \u092f\u0926\u093f \u0909\u092a\u0932\u092c\u094d\u0927 \u0939\u094b \u0924\u094b \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 (\u0926\u0942\u0938\u0930\u0940\/\u0924\u0940\u0938\u0930\u0940 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927) \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0947\u0902\u2014\u0939\u092e\u093e\u0930\u0947 \u0916\u0928\u0928 \u0938\u0902\u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915-\u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u0930\u093f\u0932\u0947 \u0928\u0947 \u0938\u093e\u0927\u093e\u0930\u0923 \u091f\u093e\u0907\u092e-\u0921\u093f\u0932\u0947 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 30% \u091d\u0942\u0920\u0940 \u091f\u094d\u0930\u093f\u092a \u0915\u094b \u0915\u092e \u0915\u093f\u092f\u093e \u0939\u0948\u0964 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938 \u0914\u0930 \u091f\u0949\u0932\u0930\u0947\u0902\u0938 \u0915\u094b \u0927\u094d\u092f\u093e\u0928 \u092e\u0947\u0902 \u0930\u0916\u0924\u0947 \u0939\u0941\u090f \u092a\u093f\u0915\u0905\u092a \u0915\u094b 1.3-1.5\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f \u092a\u0930 \u0938\u0947\u091f \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q5: \u0921\u093f\u091f\u094d\u092f\u0942\u0928\u093f\u0902\u0917 \u0930\u093f\u090f\u0915\u094d\u091f\u0930\u094d\u0938 \u0914\u0930 \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u092e\u0947\u0902 \u0915\u094d\u092f\u093e \u0905\u0902\u0924\u0930 \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u0921\u093f-\u091f\u094d\u092f\u0942\u0928\u093f\u0902\u0917 \u0930\u093f\u090f\u0915\u094d\u091f\u0930 (5-7% \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u0907\u0902\u0921\u0915\u094d\u091f\u0947\u0902\u0938) \u0938\u094d\u0925\u093e\u092f\u0940 \u0930\u0942\u092a \u0938\u0947 \u0938\u0930\u094d\u0915\u093f\u091f \u092e\u0947\u0902 \u092c\u0928\u0947 \u0930\u0939\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u094d\u0925\u093f\u0930-\u0905\u0935\u0938\u094d\u0925\u093e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938 \u0914\u0930 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0915\u094b \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u0947 \u0926\u094b\u0939\u0930\u0947 \u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902: (1) \u092a\u094d\u0930\u0924\u093f\u0927\u094d\u0935\u0928\u093f \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094b 5\u0935\u0940\u0902 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u0947 \u0928\u0940\u091a\u0947 \u0938\u094d\u0925\u093e\u0928\u093e\u0902\u0924\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u0924\u093e\u0915\u093f \u092a\u094d\u0930\u0935\u0930\u094d\u0927\u0928 \u0930\u094b\u0915\u093e \u091c\u093e \u0938\u0915\u0947, (2) \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u092c\u0922\u093c\u093e\u0915\u0930 \u0907\u0928\u0930\u0936 50-70% \u0915\u094b \u0915\u092e \u0915\u0930\u0928\u093e\u0964 \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u091c\u093c\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0930\u0942\u092a \u0938\u0947 (10-50 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u091c\u0941\u0921\u093c\u0924\u0947 \u0939\u0948\u0902, \u092b\u093f\u0930 \u0926\u0942\u0938\u0930\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u092c\u093e\u0908\u092a\u093e\u0938 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0930\u0947\u091c\u093c\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u092c\u0947\u0939\u0924\u0930 \u0907\u0928\u0930\u0936 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 (2-3\u00d7 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f \u0930\u0947\u0915\u094d\u091f\u0930 30-50\u00d7 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948) \u0932\u0947\u0915\u093f\u0928 \u091c\u091f\u093f\u0932\u0924\u093e \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902 (\u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0930\u093f\u0932\u0947)\u0964 \u092e\u0927\u094d\u092f\u092e \u0907\u0928\u0930\u0936 \u0935\u093e\u0932\u0947 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915-\u0938\u092e\u0943\u0926\u094d\u0927 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u0910\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902; \u0917\u0902\u092d\u0940\u0930 \u092c\u0948\u0915-\u091f\u0942-\u092c\u0948\u0915 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092f\u093e \u091c\u092c \u0930\u093f\u0910\u0915\u094d\u091f\u0930 \u0915\u093e \u0906\u0915\u093e\u0930\/\u0932\u093e\u0917\u0924 \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u0939\u094b, \u0924\u094b \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q6: \u092e\u0941\u091d\u0947 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u092c\u0926\u0932\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/strong><\/p>\n\n\n\n<p>AC-6b \u0915\u0940 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u092f\u0941 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0914\u0930 \u0907\u0928\u0930\u0936 \u0924\u0940\u0935\u094d\u0930\u0924\u093e \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 8,000\u201315,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 2,000\u20133,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0940 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902 (\u092e\u094b\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0932\u093f\u090f 5,000 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902)\u0964 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 500 \u00b5\u03a9 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092f\u093e \u0926\u0943\u0936\u094d\u092f \u0915\u094d\u0937\u0930\u0923 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0940 \u092e\u094b\u091f\u093e\u0908 30% \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u092e \u0939\u094b\u0928\u0947 \u092a\u0930 \u092c\u0926\u0932\u0947\u0902\u0964 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 PFC \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902, \u091c\u094b \u092a\u094d\u0930\u0924\u093f \u0918\u0902\u091f\u0947 6 \u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0940 \u0939\u0948\u0902, \u0939\u0930 2\u20134 \u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0905\u092a\u0947\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902 (8,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u00f7 6 \u0938\u0902\u091a\u093e\u0932\u0928\/\u0918\u0902\u091f\u093e \u00f7 8760 \u0918\u0902\u091f\u0947\/\u0935\u0930\u094d\u0937 \u2248 2.5 \u0935\u0930\u094d\u0937)\u0964 \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u091c\u093f\u0938\u094d\u091f\u0930\u094d\u0938 \u091c\u0940\u0935\u0928 \u0915\u094b 20,000+ \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0930\u0916\u0930\u0916\u093e\u0935 \u0932\u0949\u0917 \u0930\u0916\u0947\u0902: \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u091c\u0940\u0935\u0928 \u0907\u0928\u0930\u0936 \u0915\u0940 \u0917\u0902\u092d\u0940\u0930\u0924\u093e, \u092a\u0930\u093f\u0935\u0947\u0936\u0940\u092f \u0924\u093e\u092a\u092e\u093e\u0928, \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u00b130% \u0924\u0915 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q7: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 \u092e\u094c\u091c\u0942\u0926\u093e \u092e\u094b\u091f\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092e\u0947\u0902 AC-6b \u0930\u0947\u091f\u0947\u0921 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u094d\u0938 \u0915\u094b \u0930\u0947\u091f\u094d\u0930\u094b\u092b\u093f\u091f \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/strong><\/p>\n\n\n\n<p>\u0928\u0939\u0940\u0902\u0964 AC-6b \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0932\u093f\u090f \u0928 \u0915\u0947\u0935\u0932 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 (CuCr25 \u092c\u0928\u093e\u092e CuCr15-20) \u0905\u0932\u0917 \u0939\u094b\u0928\u0940 \u091a\u093e\u0939\u093f\u090f, \u092c\u0932\u094d\u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0948\u092a \u092d\u0940 \u092c\u0921\u093c\u093e (12-14 \u092e\u093f\u092e\u0940 \u092c\u0928\u093e\u092e 8-10 \u092e\u093f\u092e\u0940) \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0938\u093e\u0925 \u0939\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0926\u092c\u093e\u0935 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u0915\u094b \u0938\u0941\u0926\u0943\u0922\u093c \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0914\u0930 \u0906\u0930\u094d\u0915 \u091a\u0948\u0902\u092c\u0930\u094d\u0938 \u0915\u094b \u0938\u0902\u0936\u094b\u0927\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0947\u0935\u0932 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0930\u0947\u091f\u094d\u0930\u094b\u092b\u093f\u091f \u0915\u0930\u0928\u0947 \u0938\u0947 \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092e\u093f\u0932\u0924\u0940 \u0939\u0948\u2014\u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u0914\u0930 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094b \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0907\u0928\u0930\u0936 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u092a\u0942\u0930\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u094b AC-6b \u0930\u0947\u091f\u0947\u0921 \u092f\u0942\u0928\u093f\u091f \u0938\u0947 \u092c\u0926\u0932\u0947\u0902\u0964 AC-4 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u094b \u0930\u0947\u091f\u094d\u0930\u094b\u092b\u093f\u091f \u0915\u0930\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0932\u094d\u0921\u093f\u0902\u0917 (\u0905\u0928\u0941\u092a\u092f\u0941\u0915\u094d\u0924 \u0917\u0948\u092a) \u092f\u093e \u0924\u0902\u0924\u094d\u0930 \u0915\u094d\u0937\u0924\u093f (\u0909\u091a\u094d\u091a \u0907\u0928\u0930\u0936 \u092c\u0932\u094b\u0902 \u0938\u0947 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0925\u0915\u093e\u0928) \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u093e \u0939\u0948\u0964 \u092b\u0940\u0932\u094d\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0930\u0947\u091f\u094d\u0930\u094b\u092b\u093f\u091f \u0915\u093f\u090f \u0917\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094b\u0902 \u0915\u0940 100% \u0935\u093f\u092b\u0932\u0924\u093e \u0926\u0930 1,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092d\u0940\u0924\u0930 \u092a\u093e\u0908 \u0917\u0908, \u091c\u092c\u0915\u093f \u0909\u091a\u093f\u0924 AC-6b \u092f\u0942\u0928\u093f\u091f\u094d\u0938 \u092e\u0947\u0902 \u092f\u0939 12,000+ \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u0925\u0940\u0964.<\/p>","protected":false},"excerpt":{"rendered":"<p>Switching capacitor banks with vacuum contactors creates the most severe transient conditions in medium-voltage motor control applications. Inrush current during energization reaches 20-100\u00d7 rated capacitor current in the first half-cycle, sustained for 5-10 ms before decaying. This transient exceeds the making capacity of standard AC-3 or AC-4 rated contactors, causing contact welding, excessive erosion, and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2398,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-2392","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2392"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2392\/revisions"}],"predecessor-version":[{"id":3568,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2392\/revisions\/3568"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2398"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2392"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2392"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2392"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}