{"id":2409,"date":"2026-01-03T08:28:34","date_gmt":"2026-01-03T08:28:34","guid":{"rendered":"https:\/\/xbrele.com\/?p=2409"},"modified":"2026-04-07T13:32:04","modified_gmt":"2026-04-07T13:32:04","slug":"transformer-inrush-current-nuisance-trips-prevention","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/transformer-inrush-current-nuisance-trips-prevention\/","title":{"rendered":"\u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0914\u0930 \u092a\u0930\u0947\u0936\u093e\u0928 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u091f\u094d\u0930\u093f\u092a: \u0907\u0928\u0915\u0947 \u0915\u093e\u0930\u0923 \u0914\u0930 \u0930\u094b\u0915\u0925\u093e\u092e"},"content":{"rendered":"<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0924\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u092c\u0938\u0947 \u0906\u092e \u0928\u0941\u0915\u0940\u0932\u093e \u091f\u094d\u0930\u093f\u092a \u0938\u094d\u0925\u093f\u0924\u093f \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094b\u0930 \u0915\u094b \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0939\u094b\u0924\u0947 \u0939\u0940 \u092b\u094d\u0932\u0915\u094d\u0938 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948, \u0914\u0930 \u092f\u0926\u093f \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u0936\u0942\u0928\u094d\u092f-\u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 \u0915\u0947 \u092a\u093e\u0938 \u0939\u094b\u0924\u0940 \u0939\u0948, \u0924\u094b \u092b\u094d\u0932\u0915\u094d\u0938 \u0924\u0930\u0902\u0917\u0930\u0942\u092a \u0905\u0938\u092e\u092e\u093f\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u2014\u091c\u093f\u0938\u0938\u0947 \u0915\u094b\u0930 \u0917\u0939\u0930\u0940 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u092e\u0947\u0902 \u091a\u0932\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0927\u093e\u0930\u093e \u0938\u093e\u092e\u093e\u0928\u094d\u092f 0.5-2% \u0930\u0947\u091f\u0947\u0921 \u0932\u094b\u0921 \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 8-15\u00d7 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u092a\u0942\u0930\u094d\u0923-\u0932\u094b\u0921 \u0927\u093e\u0930\u093e \u0924\u0915 \u092a\u0939\u0941\u0902\u091a \u091c\u093e\u0924\u0940 \u0939\u0948, \u091c\u094b 0.1-0.5 \u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u092c\u0928\u0940 \u0930\u0939\u0924\u0940 \u0939\u0948 \u0914\u0930 \u092b\u093f\u0930 \u0918\u093e\u0924\u0940\u092f \u0930\u0942\u092a \u0938\u0947 \u0918\u091f \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u0915\u094d\u0937\u0923\u093f\u0915 \u0918\u091f\u0928\u093e \u0916\u0930\u093e\u092c \u0938\u092e\u0928\u094d\u0935\u093f\u0924 \u0913\u0935\u0930\u0915\u0930\u0902\u091f \u0930\u093f\u0932\u0947 \u0915\u0940 \u092a\u093f\u0915\u0905\u092a \u0925\u094d\u0930\u0947\u0936\u094b\u0932\u094d\u0921 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092c\u094d\u0930\u0947\u0915\u0930 \u0909\u0928 \u0915\u093e\u0932\u094d\u092a\u0928\u093f\u0915 \u201c\u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902\u201d \u092a\u0930 \u091f\u094d\u0930\u093f\u092a \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u0935\u093e\u0938\u094d\u0924\u0935 \u092e\u0947\u0902 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092d\u094c\u0924\u093f\u0915\u0940 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0938\u092e\u0938\u094d\u092f\u093e \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0938\u094d\u0935\u093f\u091a (ATS) \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u0914\u0930 \u092d\u0940 \u091c\u091f\u093f\u0932 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948 \u091c\u0939\u093e\u0901 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u092f\u093e \u0910\u0938\u0947 \u0938\u093f\u0938\u094d\u091f\u092e\u094b\u0902 \u092e\u0947\u0902 \u091c\u0939\u093e\u0901 \u0915\u0908 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0915\u094d\u0930\u092e\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0947 \u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f\u092a\u0942\u0930\u094d\u0923 \u0907\u0928\u0930\u0936 \u0939\u094b\u0924\u093e \u0939\u0948\u0964\u0924\u0940\u0928 2000 kVA \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0935\u093e\u0932\u0940 \u0915\u093f\u0938\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u092e\u0947\u0902 \u0915\u0947\u0935\u0932 \u0907\u0928\u0930\u0936 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u0940 \u092a\u094d\u0930\u0924\u093f \u0935\u0930\u094d\u0937 15\u201320 \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u091f\u094d\u0930\u093f\u092a \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u2014\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u094d\u0930\u093f\u092a \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u092e\u0947\u0902 \u0930\u0941\u0915\u093e\u0935\u091f, \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u092a\u0930 \u0924\u0928\u093e\u0935, \u0914\u0930 \u201c\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0926\u094b\u0937\u094b\u0902\u201d \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0949\u0932 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u0940 \u0939\u0948, \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u092d\u0940 \u0926\u094b\u0939\u0930\u093e \u0928\u0939\u0940\u0902 \u092a\u093e\u0924\u093e\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u092d\u094c\u0924\u093f\u0915\u0940, \u0909\u0928 \u0915\u093e\u0930\u0915\u094b\u0902 \u0915\u093e \u0905\u0927\u094d\u092f\u092f\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948 \u091c\u094b \u0915\u0941\u091b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u0926\u0942\u0938\u0930\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0905\u0927\u093f\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u0917\u094d\u0930\u0938\u094d\u0924 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u0909\u0928 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0924\u0925\u093e \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u0938\u092e\u093e\u0927\u093e\u0928\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u0938\u094d\u0924\u0941\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948 \u091c\u094b \u0926\u094b\u0937 \u092a\u0939\u091a\u093e\u0928 \u0938\u0947 \u0938\u092e\u091d\u094c\u0924\u093e \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u0907\u0928\u0930\u0936-\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u091d\u0942\u0920\u0940 \u091f\u094d\u0930\u093f\u092a\u094b\u0902 \u0915\u094b 90%+ \u0924\u0915 \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f: \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915 \u0915\u0947 \u0938\u093e\u0925 \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u091f\u094d\u0930\u093f\u092a \u0915\u094b \u0930\u094b\u0915\u0947\u0902\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/5aj8nbikJns?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-transformer-inrush-exceeds-normal-magnetizing-current\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f\u0915\u0930\u0923 \u0927\u093e\u0930\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u094d\u092f\u094b\u0902 \u0939\u094b\u0924\u0940 \u0939\u0948<\/h2>\n\n\n\n<p>\u0938\u094d\u0925\u093f\u0930-\u0905\u0935\u0938\u094d\u0925\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f\u0915\u0930\u0923 \u0927\u093e\u0930\u093e \u091b\u094b\u091f\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u2014\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092f\u0939 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u092d\u093e\u0930 \u0915\u093e 0.5\u20132% \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0927\u093e\u0930\u093e \u092b\u0948\u0930\u093e\u0921\u0947 \u0915\u0947 \u0928\u093f\u092f\u092e \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0942\u092a\u093e\u0902\u0924\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u091c\u092c \u0906\u092a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0935\u093f\u0939\u0940\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0915\u094b\u0930 \u092e\u0947\u0902 \u0915\u0941\u091b \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u092b\u0901\u0938\u093e \u0930\u0939\u0924\u093e \u0939\u0948 (\u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f\u0915\u0930\u0923), \u091c\u094b \u0915\u094b\u0930 \u0938\u094d\u091f\u0940\u0932 \u0915\u0940 \u0917\u0941\u0923\u0927\u0930\u094d\u092e\u094b\u0902 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0947 \u0939\u0941\u090f \u091a\u0930\u092e \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u093e 30\u201380% \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092a\u0941\u0928\u0903 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u0907\u0928\u0930\u0936 \u0924\u092c \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u091c\u092c:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0936\u0947\u0937 \u092a\u094d\u0930\u0935\u093e\u0939<\/strong>\u00a0\u0909\u091a\u094d\u091a \u0939\u0948 (\u03a6_max \u0915\u093e 80%)<\/li>\n\n\n\n<li><strong>\u0924\u0924\u094d\u0915\u093e\u0932 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917<\/strong>\u00a0\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u0942\u0928\u094d\u092f-\u092a\u093e\u0930 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0939\u094b\u0924\u093e \u0939\u0948<\/li>\n\n\n\n<li><strong>\u0927\u093e\u0930\u093e-\u0927\u094d\u0930\u0941\u0935\u0940\u092f\u0924\u093e<\/strong>\u00a0\u0936\u0947\u0937 \u0914\u0930 \u0932\u093e\u0917\u0942 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0902\u0930\u0947\u0916\u093f\u0924 (\u092a\u0930\u093f\u092e\u093e\u0923\u0940\u092f) \u0939\u0948\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p>\u0907\u0928 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902, \u0915\u0941\u0932 \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u0940 \u092e\u093e\u0902\u0917 \u092a\u0939\u0941\u0901\u091a\u0924\u0940 \u0939\u0948:<br>\u03a6<sub>\u0915\u0941\u0932<\/sub>\u00a0= \u03c6<sub>\u0932\u093e\u0917\u0942 \u0915\u093f\u092f\u093e \u0917\u092f\u093e<\/sub>\u00a0+ \u092b\u093e\u0908<sub>\u0936\u0947\u0937<\/sub>\u00a0\u2248 1.0 + 0.8 =\u00a0<strong>1.8 p.u.<\/strong><br><br>\u0915\u094b\u0930 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u0932\u0917\u092d\u0917 1.2\u20131.3 p.u. \u092a\u0930 \u0939\u094b\u0924\u0940 \u0939\u0948, \u0907\u0938\u0932\u093f\u090f \u092f\u0939 1.8 p.u. \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u094b\u0930 \u0915\u094b \u0917\u0939\u0930\u093e\u0908 \u0938\u0947 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u092e\u0947\u0902 \u0927\u0915\u0947\u0932 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u092e\u0947\u0902 \u092a\u093e\u0930\u0917\u092e\u094d\u092f\u0924\u093e \u0922\u0939 \u091c\u093e\u0924\u0940 \u0939\u0948\u2014\u092b\u094d\u0932\u0915\u094d\u0938 \u0914\u0930 \u0927\u093e\u0930\u093e \u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0938\u0902\u092c\u0902\u0927 \u0917\u0948\u0930-\u0930\u0947\u0916\u0940\u092f \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0914\u0930 \u0906\u0935\u0936\u094d\u092f\u0915 \u092b\u094d\u0932\u0915\u094d\u0938 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0927\u093e\u0930\u093e \u092e\u0947\u0902 \u092d\u093e\u0930\u0940 \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u0930\u0928\u0940 \u092a\u0921\u093c\u0924\u0940 \u0939\u0948\u0964<\/p>\n\n\n\n<p><strong>\u091a\u0930\u092e \u0907\u0928\u0930\u0936 \u092a\u0930\u093f\u092e\u093e\u0923<\/strong>\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 (200 kVA\u20132500 kVA) \u0915\u0947 \u0932\u093f\u090f \u092a\u0942\u0930\u094d\u0923-\u0932\u094b\u0921 \u0927\u093e\u0930\u093e \u0915\u093e 8\u201312 \u0917\u0941\u0928\u093e\u0964 \u0909\u091a\u094d\u091a \u0936\u0915\u094d\u0924\u093f \u0935\u093e\u0932\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 (&gt;10 MVA) \u0909\u091a\u094d\u091a \u0915\u094b\u0930 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e (\u0915\u092e \u0939\u093e\u0928\u093f, \u0909\u091a\u094d\u091a \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u092a\u094d\u0930\u0924\u093f\u0927\u093e\u0930\u0923) \u0915\u0947 \u0915\u093e\u0930\u0923 15\u201320 \u0917\u0941\u0928\u093e \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0915\u094d\u0937\u092f \u0938\u092e\u092f \u0938\u094d\u0925\u093f\u0930\u093e\u0902\u0915<\/strong>: \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u0928\u093f\u092f\u092e\u0928 \u0914\u0930 \u0915\u094b\u0930 \u0939\u093e\u0928\u093f \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924\u0964 \u091b\u094b\u091f\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947 \u0915\u094d\u0937\u0940\u0923 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 (50\u2013200 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092a\u094d\u0930\u0924\u093f \u0907\u0915\u093e\u0908 \u0909\u091a\u094d\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094d\u0937\u0923\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u094b \u0926\u092c\u093e \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u092c\u0921\u093c\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0915\u094b \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902 (200\u2013500 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)\u0964.<\/p>\n\n\n\n<p>\u0938\u092e\u091d\u0928\u093e&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/transformer-impedance-percentage-guide\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e Z%<\/a>&nbsp;\u092f\u0939 \u0938\u0902\u0926\u0930\u094d\u092d \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0907\u0928\u0930\u0936 \u0935\u094d\u092f\u0935\u0939\u093e\u0930 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u0938\u0947 \u0915\u094d\u092f\u094b\u0902 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u2014\u0907\u0928\u0930\u0936 \u090f\u0915 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0918\u091f\u0928\u093e \u0939\u0948 \u091c\u092c\u0915\u093f \u092b\u0949\u0932\u094d\u091f \u0927\u093e\u0930\u093e \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0940\/\u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0936\u0940\u0932 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01.webp\" alt=\"\u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0914\u0930 \u0915\u094b\u0930 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u0915\u0947 \u0915\u093e\u0930\u0923 1.8 \u092a\u094d\u0930\u0924\u093f-\u0907\u0915\u093e\u0908 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u0947 \u0936\u093f\u0916\u0930 \u0915\u0947 \u0938\u093e\u0925 \u0938\u092e\u092f \u0915\u0947 \u0935\u093f\u0930\u0941\u0926\u094d\u0927 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u092b\u094d\u0932\u0915\u094d\u0938 \u0926\u093f\u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u0917\u094d\u0930\u093e\u092b\" class=\"wp-image-2410\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 1. \u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u093e \u0935\u094d\u092f\u0935\u0939\u093e\u0930: \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092b\u094d\u0932\u0915\u094d\u0938 (0.8 \u092a\u0940\u092f\u0942) \u0914\u0930 \u0936\u0942\u0928\u094d\u092f-\u092a\u093e\u0930\u0917\u092e\u0928 \u092a\u0930 \u0932\u093e\u0917\u0942 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0941\u0932 \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u094b 1.8 \u092a\u0940\u092f\u0942 \u0924\u0915 \u0932\u0947 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u0938\u0940\u092e\u093e (1.2 \u092a\u0940\u092f\u0942) \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u0948 \u0914\u0930 \u0935\u093f\u0936\u093e\u0932 \u091a\u0941\u0902\u092c\u0928 \u0927\u093e\u0930\u093e \u0915\u093e \u0905\u091a\u093e\u0928\u0915 \u092a\u094d\u0930\u0935\u093e\u0939 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"harmonic-content-the-key-to-discrimination\">\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940: \u092d\u0947\u0926\u092d\u093e\u0935 \u0915\u0940 \u0915\u0941\u0902\u091c\u0940<\/h2>\n\n\n\n<p>\u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u092e\u0947\u0902 30\u201370% \u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0915\u0940 \u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 (50 \u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 100 \u0939\u0930\u094d\u091f\u094d\u091c\u093c, 60 \u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 120 \u0939\u0930\u094d\u091f\u094d\u091c\u093c) \u0939\u094b\u0924\u0940 \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092b\u094d\u0932\u0915\u094d\u0938 \u0935\u0947\u0935\u092b\u093c\u0949\u0930\u094d\u092e \u0935\u093f\u0937\u092e \u0939\u0948\u2014\u092f\u0939 \u090f\u0915 \u0905\u0930\u094d\u0927-\u091a\u0915\u094d\u0930 \u092e\u0947\u0902 \u0938\u0902\u0924\u0943\u092a\u094d\u0924 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 \u0932\u0947\u0915\u093f\u0928 \u0926\u0942\u0938\u0930\u0947 \u0905\u0930\u094d\u0927-\u091a\u0915\u094d\u0930 \u092e\u0947\u0902 \u0930\u0948\u0916\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u0902\u0915\u0947\u0924 \u0907\u0928\u0930\u0936 \u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u092e\u0941\u0916\u094d\u092f\u0924\u0903 \u092e\u0942\u0932 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u0940 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0906\u092e \u0907\u0928\u0930\u0936 \u0915\u093e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092e\u0942\u0932\u092d\u0942\u0924 (50\/60 \u0939\u0930\u094d\u091f\u094d\u091c\u093c)<\/strong>: 100% (\u0938\u0902\u0926\u0930\u094d\u092d)<\/li>\n\n\n\n<li><strong>\u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915<\/strong>: 30-70% (\u092a\u094d\u0930\u092e\u0941\u0916 \u0935\u093f\u0936\u0947\u0937\u0924\u093e)<\/li>\n\n\n\n<li><strong>\u0924\u0943\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915<\/strong>: 10-20%<\/li>\n\n\n\n<li><strong>\u0909\u091a\u094d\u091a \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938<\/strong>: &lt;5%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u093e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u0902\u0918\u091f\u0928<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092e\u0942\u0932\u092d\u0942\u0924<\/strong>: 100%<\/li>\n\n\n\n<li><strong>\u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915<\/strong>: &lt;5% (\u0905\u092a\u094d\u0930\u092e\u093e\u0923\u094d\u092f)<\/li>\n<\/ul>\n\n\n\n<p>\u092f\u0939 \u0905\u0902\u0924\u0930 \u0938\u0915\u094d\u0937\u092e \u092c\u0928\u093e\u0924\u093e \u0939\u0948&nbsp;<strong>\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0930\u093f\u0932\u0947<\/strong>&nbsp;\u0907\u0928\u0930\u0936 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f\u0964 \u0930\u093f\u0932\u0947 \u0926\u0942\u0938\u0930\u0947 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0914\u0930 \u092e\u0942\u0932 \u0927\u093e\u0930\u093e \u0915\u0947 \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u094b \u092e\u093e\u092a\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u092f\u0939 \u0905\u0928\u0941\u092a\u093e\u0924 \u090f\u0915 \u0938\u0940\u092e\u093e (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 15\u201320%) \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0930\u093f\u0932\u0947 \u0907\u0938 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u0907\u0928\u0930\u0936 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u092a\u0939\u091a\u093e\u0928\u0924\u093e \u0939\u0948 \u0914\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0905\u0935\u0927\u093f (0.5\u20132 \u0938\u0947\u0915\u0902\u0921) \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0924\u0930\u094d\u0915 (\u0938\u0930\u0932\u0940\u0915\u0943\u0924)<\/strong>:<br>\u092f\u0926\u093f (\u092e\u0948\u0902<sub>\u0926\u0942\u0938\u0930\u093e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915<\/sub>\u00a0\/ \u092e\u0948\u0902<sub>\u092e\u094c\u0932\u093f\u0915<\/sub>) &gt; 0.18 \u0924\u092c<br>\u00a0\u00a0\u0924\u0924\u094d\u0915\u093e\u0932 \u092f\u093e\u0924\u094d\u0930\u093e \u0905\u0935\u0930\u0941\u0926\u094d\u0927 \u0915\u0930\u0947\u0902 (50\/51)<br>\u00a0\u00a00.5-1.0 \u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0913\u0935\u0930\u0915\u0930\u0902\u091f \u091f\u094d\u0930\u093f\u092a \u0915\u0930\u0947\u0902<br>\u0905\u0928\u094d\u092f\u0925\u093e<br>\u00a0\u00a0\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0902\u091a\u093e\u0932\u0928<br>\u0905\u0902\u0924 \u092f\u0926\u093f<\/p>\n\n\n\n<p>95 \u0935\u093f\u0924\u0930\u0923 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u093e \u0915\u093f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0928\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u091f\u094d\u0930\u093f\u092a\u094b\u0902 \u0915\u094b \u0938\u093e\u0927\u093e\u0930\u0923 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0913\u0935\u0930\u0915\u0930\u0902\u091f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 85\u201395% \u0924\u0915 \u0915\u092e \u0915\u0930 \u0926\u093f\u092f\u093e\u2014\u092c\u093f\u0928\u093e \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0926\u094b\u0937-\u0938\u092e\u093e\u0927\u093e\u0928 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u093f\u090f\u0964.<\/p>\n\n\n\n<p>\u0935\u094d\u092f\u093e\u092a\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0947 \u0932\u093f\u090f \u0926\u0947\u0916\u0947\u0902&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/transformer-protection-vcb-inrush-coordination-mistakes\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0907\u0928\u0930\u0936 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0902\u0930\u0915\u094d\u0937\u0923<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"factors-that-worsen-inrush-transformer-design-and-system-conditions\">\u0907\u0928\u0930\u0936 \u0915\u094b \u092c\u0922\u093c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u093e\u0930\u0915: \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0914\u0930 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901<\/h2>\n\n\n\n<p>\u0938\u092d\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u092e\u093e\u0928 \u0907\u0928\u0930\u0936 \u0928\u0939\u0940\u0902 \u0926\u093f\u0916\u093e\u0924\u0947\u0964 \u0917\u0902\u092d\u0940\u0930\u0924\u093e \u0915\u094b \u091b\u0939 \u0915\u093e\u0930\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n\n\n\n<p><strong>1. \u092e\u0941\u0916\u094d\u092f \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0905\u0928\u093e\u091c-\u0909\u0928\u094d\u092e\u0941\u0916 \u0938\u093f\u0932\u093f\u0915\u0949\u0928 \u0938\u094d\u091f\u0940\u0932 (\u0938\u0940\u0906\u0930\u091c\u0940\u0913)<\/strong>: \u0909\u091a\u094d\u091a \u092a\u093e\u0930\u0917\u092e\u094d\u092f\u0924\u093e, \u0915\u092e \u0939\u093e\u0928\u093f \u2192 60-80% \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092a\u094d\u0930\u0935\u093e\u0939 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948 \u2192 \u0905\u0927\u093f\u0915 \u0924\u0940\u0935\u094d\u0930 \u0907\u0928\u0930\u0936<\/li>\n\n\n\n<li><strong>\u0905\u0915\u093e\u0930\u094d\u092c\u0928\u093f\u0915 \u0927\u093e\u0924\u0941 \u0915\u0947 \u092e\u0942\u0932<\/strong>: \u0928\u093f\u092e\u094d\u0928 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092a\u094d\u0930\u0935\u093e\u0939 (30-50%) \u2192 \u0915\u092e \u0907\u0928\u0930\u0936 \u0932\u0947\u0915\u093f\u0928 \u0909\u091a\u094d\u091a \u0932\u093e\u0917\u0924<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0930\u0947\u091f\u093f\u0902\u0917<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092c\u0921\u093c\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 (&gt;2500 kVA) \u0915\u0940 \u092a\u094d\u0930\u0924\u093f \u0907\u0915\u093e\u0908 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915\u0924\u093e \u0915\u092e \u0939\u094b\u0924\u0940 \u0939\u0948 \u2192 \u0926\u0940\u0930\u094d\u0918 \u0915\u094d\u0937\u092f \u0938\u092e\u092f \u0938\u094d\u0925\u093f\u0930\u093e\u0902\u0915 \u2192 \u0928\u093f\u0930\u0902\u0924\u0930 \u0907\u0928\u0930\u0936<\/li>\n<\/ul>\n\n\n\n<p><strong>3. \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c\u0947\u0936\u0928 \u092a\u0930 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092a\u094d\u0930\u0935\u093e\u0939<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092a\u094d\u0930\u093e\u0915\u0943\u0924\u093f\u0915 \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c\u0947\u0936\u0928 (\u092c\u094d\u0930\u0947\u0915\u0930 \u092f\u093e\u0926\u0943\u091a\u094d\u091b\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0916\u0941\u0932\u0924\u093e \u0939\u0948): \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092b\u094d\u0932\u0915\u094d\u0938 30\u201380% \u0924\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0930\u0941\u0915\u093e\u0935\u091f (\u0936\u0942\u0928\u094d\u092f \u0927\u093e\u0930\u093e \u092a\u0930 \u0916\u0941\u0932\u0928\u093e): \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 ~80% (\u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u0938\u094d\u0925\u093f\u0924\u093f)<\/li>\n<\/ul>\n\n\n\n<p><strong>4. \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0915\u0920\u094b\u0930 \u0938\u094d\u0930\u094b\u0924<\/strong>\u00a0(\u0928\u093f\u092e\u094d\u0928 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e, \u092c\u0921\u093c\u0947 \u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930): \u0907\u0928\u0930\u0936 \u092a\u0940\u0915 \u0915\u0947\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0926\u094d\u0935\u093e\u0930\u093e \u0938\u0940\u092e\u093f\u0924 \u2192 \u0909\u091a\u094d\u091a \u092a\u0940\u0915<\/li>\n\n\n\n<li><strong>\u0915\u092e\u091c\u094b\u0930 \u0938\u094d\u0930\u094b\u0924<\/strong>\u00a0(\u0932\u0902\u092c\u093e \u092b\u0940\u0921\u0930, \u091b\u094b\u091f\u093e \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930): \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0907\u0928\u0930\u0936 \u0915\u094b \u0926\u092c\u093e\u0924\u0940 \u0939\u0948 \u2192 \u0915\u092e \u0936\u093f\u0916\u0930 \u0932\u0947\u0915\u093f\u0928 \u0932\u0902\u092c\u0940 \u0905\u0935\u0927\u093f<\/li>\n<\/ul>\n\n\n\n<p><strong>5. \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b\u0923<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u0942\u0928\u094d\u092f-\u092a\u093e\u0930\u0917\u092e\u0928<\/strong>\u0905\u0927\u093f\u0915\u0924\u092e \u0935\u093f\u0937\u092e \u092a\u094d\u0930\u0935\u093e\u0939 \u2192 \u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u0907\u0928\u0930\u0936<\/li>\n\n\n\n<li><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u093f\u0916\u0930<\/strong>: \u0938\u092e\u092e\u093f\u0924 \u092b\u094d\u0932\u0915\u094d\u0938 \u0938\u0902\u091a\u092f \u2192 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0907\u0928\u0930\u0936 (1-2\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e)<\/li>\n<\/ul>\n\n\n\n<p><strong>6. \u092a\u093f\u091b\u0932\u093e \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0907\u0924\u093f\u0939\u093e\u0938<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c\u0947\u0936\u0928 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092d\u093e\u0930\u0940 \u0932\u094b\u0921 \u092a\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u093f\u092f\u093e \u0917\u092f\u093e: \u0909\u091a\u094d\u091a \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939<\/li>\n\n\n\n<li>\u0936\u0942\u0928\u094d\u092f-\u092d\u093e\u0930 \u092a\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0906\u0907\u0921\u0932\u093f\u0902\u0917: \u0928\u093f\u092e\u094d\u0928 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02.webp\" alt=\"\u092c\u093e\u0930 \u091a\u093e\u0930\u094d\u091f \u091c\u094b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0915\u0940 \u0917\u0902\u092d\u0940\u0930\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u091b\u0939 \u0915\u093e\u0930\u0915\u094b\u0902 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 \u0915\u094b\u0930 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b\u0923 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u092f\u094b\u0917\u0926\u093e\u0928\u0915\u0930\u094d\u0924\u093e \u0939\u0948\u0902\u0964\" class=\"wp-image-2413\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 2. \u0907\u0928\u0930\u0936 \u0924\u0940\u0935\u094d\u0930\u0924\u093e \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u091b\u0939 \u0915\u093e\u0930\u0915: \u0915\u094b\u0930 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e (\u0936\u0947\u0937 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u092a\u094d\u0930\u0924\u093f\u0927\u093e\u0930\u0923 \u0915\u0947 \u0915\u093e\u0930\u0923 60\u201380% \u092f\u094b\u0917\u0926\u093e\u0928), \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b\u0923 (\u0936\u0942\u0928\u094d\u092f-\u092a\u093e\u0930\u0917\u092e\u0928 \u0915\u0947 \u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u092e\u093e\u092e\u0932\u0947 \u0914\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c-\u0936\u093f\u0916\u0930 \u0915\u0947 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092e\u093e\u092e\u0932\u0947 \u0915\u0947 \u092c\u0940\u091a 50% \u092d\u093f\u0928\u094d\u0928\u0924\u093e), \u0914\u0930 \u0936\u0947\u0937 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u093e \u0938\u094d\u0924\u0930 \u0907\u0928\u0930\u0936 \u092a\u0930\u093f\u092e\u093e\u0923 \u092a\u0930 \u0939\u093e\u0935\u0940 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-coordination-strategies-to-prevent-nuisance-trips\">\u0909\u092a\u0926\u094d\u0930\u0935 \u092f\u093e\u0924\u094d\u0930\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901<\/h2>\n\n\n\n<p>\u092a\u093e\u0901\u091a \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0907\u0928\u0930\u0936-\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u092f\u093e\u0924\u094d\u0930\u093e\u0913\u0902 \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0938\u092c\u0938\u0947 \u0938\u0930\u0932 (\u0932\u0947\u0915\u093f\u0928 \u0938\u092c\u0938\u0947 \u0915\u092e \u091a\u092f\u0928\u093e\u0924\u094d\u092e\u0915) \u0938\u0947 \u0932\u0947\u0915\u0930 \u0938\u092c\u0938\u0947 \u092a\u0930\u093f\u0937\u094d\u0915\u0943\u0924 \u0924\u0915 \u0938\u0942\u091a\u0940\u092c\u0926\u094d\u0927 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-1-time-delayed-overcurrent\">\u0930\u0923\u0928\u0940\u0924\u093f 1: \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0905\u0924\u093f\u092a\u094d\u0930\u0935\u093e\u0939<\/h3>\n\n\n\n<p>\u0913\u0935\u0930\u0915\u0930\u0902\u091f \u0930\u093f\u0932\u0947 \u092a\u0930 \u0938\u092e\u092f \u0935\u093f\u0932\u0902\u092c \u0915\u094b \u0905\u0927\u093f\u0915\u0924\u092e \u0907\u0928\u0930\u0936 \u0915\u094d\u0937\u092f \u0905\u0935\u0927\u093f \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u0947 \u0924\u0915 \u092c\u0922\u093c\u093e\u090f\u0901\u0964 1000\u20132500 kVA \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0938\u092e\u092f \u0935\u093f\u0932\u0902\u092c \u0915\u094b 0.5\u20131.0 \u0938\u0947\u0915\u0902\u0921 \u092a\u0930 \u0938\u0947\u091f \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0932\u093e\u092d<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0932\u093e\u0917\u0942 \u0915\u0930\u0928\u093e \u0938\u0930\u0932 (\u0938\u092d\u0940 \u0938\u0902\u0916\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0930\u093f\u0932\u0947 \u0928\u093f\u0936\u094d\u091a\u093f\u0924-\u0938\u092e\u092f \u0915\u093e \u0938\u092e\u0930\u094d\u0925\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902)<\/li>\n\n\n\n<li>\u0915\u094b\u0908 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092e\u093e\u092a\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0928\u0939\u0940\u0902<\/li>\n\n\n\n<li>\u0915\u093f\u0938\u0940 \u092d\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u092a\u0930 \u0915\u093e\u092e \u0915\u0930\u0924\u093e \u0939\u0948<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0940\u092e\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0916\u0930\u093e\u092c\u0940 \u092d\u0940 0.5-1.0 \u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948 (\u0935\u093f\u0924\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f, \u0932\u0947\u0915\u093f\u0928 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u093e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u0938\u094d\u092f\u093e\u0917\u094d\u0930\u0938\u094d\u0924)<\/li>\n\n\n\n<li>\u0907\u0928\u0930\u0936 \u0914\u0930 \u0928\u093f\u0930\u0902\u0924\u0930 \u0913\u0935\u0930\u0932\u094b\u0921 \u092e\u0947\u0902 \u0905\u0902\u0924\u0930 \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u093e\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092a\u093f\u0915\u0905\u092a: 1.3\u20131.5\u00d7 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f<\/li>\n\n\n\n<li>\u0935\u093f\u0932\u0902\u092c: 0.8-1.2 \u0938\u0947\u0915\u0902\u0921 (\u0928\u093f\u0936\u094d\u091a\u093f\u0924-\u0938\u092e\u092f)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-2-harmonic-restraint-preferred-for-automatic-systems\">\u0930\u0923\u0928\u0940\u0924\u093f 2: \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 (\u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u0930\u0940\u092f)<\/h3>\n\n\n\n<p>\u0906\u0927\u0941\u0928\u093f\u0915 \u0930\u093f\u0932\u0947 (SEL-387, ABB REF615, Schneider Sepam) \u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u0915\u094b \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u091c\u092c I_2nd \/ I_fundamental &gt; 18% \u0939\u094b\u0924\u093e \u0939\u0948, \u0924\u094b \u0930\u093f\u0932\u0947 \u092a\u094d\u0930\u094b\u0917\u094d\u0930\u093e\u092e \u0915\u0940 \u0917\u0908 \u0905\u0935\u0927\u093f \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0915\u094b \u0930\u094b\u0915 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0906\u092e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 (SEL-387)<\/strong>:<br><code>87P = 0.25 \u092a\u0941<\/code>\u00a0(\u0921\u093f\u092b\u0930\u0947\u0902\u0936\u093f\u092f\u0932 \u092a\u093f\u0915\u0905\u092a, 25% \u0915\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0930\u0947\u091f\u093f\u0902\u0917)<br><code>87S = 35%<\/code>\u00a0(\u0926\u0930\u093e\u0930 \u0915\u0947 \u092a\u093e\u0930 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0915\u0947 \u0932\u093f\u090f \u0922\u0932\u093e\u0928)<br><code>\u092a\u0940\u0938\u0940\u091f\u09402 = 181\u091f\u0940\u092a\u09403\u091f\u0940<\/code>\u00a0(\u0926\u094d\u0935\u093f\u0924\u0940\u092f-\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0905\u0935\u0930\u094b\u0927\u0915 \u0938\u0940\u092e\u093e)<br><code>INHST = 5.0 \u091a\u0915\u094d\u0930<\/code>\u00a0(\u092c\u094d\u0932\u0949\u0915 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938 100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0924\u0915 \u092c\u0928\u0947 \u0930\u0939\u0928\u093e \u091a\u093e\u0939\u093f\u090f)<\/p>\n\n\n\n<p><strong>\u0932\u093e\u092d<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0938\u0947 \u0907\u0928\u0930\u0936 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0924\u093e \u0939\u0948 (\u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0932\u093f\u090f \u0915\u094b\u0908 \u0926\u0947\u0930\u0940 \u0928\u0939\u0940\u0902)<\/li>\n\n\n\n<li>\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 (\u090f\u091f\u0940\u090f\u0938, \u0932\u094b\u0921 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0940\u092e\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092e\u093e\u092a\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948 (\u0930\u093f\u0932\u0947 \u0915\u0940 \u0932\u093e\u0917\u0924 \u092c\u0922\u093c \u091c\u093e\u0924\u0940 \u0939\u0948)<\/li>\n\n\n\n<li>\u0915\u0941\u091b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0921\u093f\u091c\u093c\u093e\u0907\u0928\u094b\u0902 (\u0935\u093f\u0936\u0947\u0937\u0915\u0930 \u092a\u0941\u0930\u093e\u0928\u0947 \u092f\u0942\u0928\u093f\u091f\u094d\u0938) \u092e\u0947\u0902 &lt;15% \u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092e\u0948\u0926\u093e\u0928\u0940 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928<\/strong>\u0939\u092e\u0928\u0947 \u092a\u094d\u0930\u0924\u093f\u0926\u093f\u0928 4\u20136 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0935\u093e\u0932\u0940 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u092e\u0947\u0902 \u0915\u0947\u0935\u0932 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 92% \u0909\u092a\u0926\u094d\u0930\u0935 \u092f\u093e\u0924\u094d\u0930\u093e\u0913\u0902 \u092e\u0947\u0902 \u0915\u092e\u0940 \u0915\u094b \u092e\u093e\u092a\u093e\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-3-controlled-switching-point-on-wave\">\u0930\u0923\u0928\u0940\u0924\u093f 3: \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 (\u092a\u0949\u0907\u0902\u091f-\u0911\u0928-\u0935\u0947\u0935)<\/h3>\n\n\n\n<p>\u0936\u0942\u0928\u094d\u092f-\u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 \u0915\u0947 \u092c\u091c\u093e\u092f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u093f\u0916\u0930 \u092a\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0915\u0930\u0947\u0902\u0964 \u092b\u094d\u0932\u0915\u094d\u0938 \u0938\u092e\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092c\u0922\u093c\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u091f\u0932 \u091c\u093e\u0924\u0940 \u0939\u0948 \u2192 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0915\u093e 1\u20132 \u0917\u0941\u0928\u093e \u0924\u0915 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u092e\u0932<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u092e\u0915\u093e\u0932\u093f\u0915 \u0938\u092e\u093e\u092a\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0915 (\u090f\u092c\u0940\u092c\u0940 \u0938\u094d\u0935\u093f\u091a\u0938\u093f\u0902\u0915, \u0938\u0940\u092e\u0947\u0902\u0938 \u092a\u094b\u0938\u093e)<\/li>\n\n\n\n<li>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091a\u0930\u0923 \u092e\u093e\u092a\u0947\u0902, \u0907\u0937\u094d\u091f\u0924\u092e \u0915\u094b\u0923 \u092a\u0930 \u0915\u094d\u0932\u094b\u091c \u0915\u092e\u093e\u0902\u0921 \u091c\u093e\u0930\u0940 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0928\u093f\u0930\u0902\u0924\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u0947 \u0938\u092e\u092f (\u00b12 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092a\u0941\u0928\u0930\u093e\u0935\u0943\u0924\u094d\u0924\u093f) \u0935\u093e\u0932\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0932\u093e\u092d<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u0940 \u092a\u0930\u0935\u093e\u0939 \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u0907\u0928\u0930\u0936 \u0915\u094b 85\u201395% \u0924\u0915 \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u093e \u0939\u0948<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0940\u092e\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0909\u091a\u094d\u091a \u0932\u093e\u0917\u0924 (\u092a\u094d\u0930\u0924\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0902\u091f\u094d\u0930\u094b\u0932\u0930 $5,000-$15,000)<\/li>\n\n\n\n<li>\u0938\u091f\u0940\u0915 \u0938\u092e\u092f\u0928 \u0915\u0947 \u0938\u093e\u0925 VCB \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e (\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0935\u0938\u0902\u0924 \u0924\u0902\u0924\u094d\u0930 \u0905\u0927\u093f\u0915 \u0938\u0941\u0938\u0902\u0917\u0924)<\/li>\n\n\n\n<li>\u092a\u0941\u0930\u093e\u0928\u0947 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092e\u0947\u0902 \u0930\u0947\u091f\u094d\u0930\u094b\u092b\u093f\u091f \u0928\u0939\u0940\u0902 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e<\/strong>: \u092c\u0921\u093c\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 (&gt;5 MVA), \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917, \u0921\u093e\u0909\u0928\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u092e\u0947\u0902 \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0909\u092a\u0915\u0930\u0923<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-4-pre-insertion-resistors\">\u0930\u0923\u0928\u0940\u0924\u093f 4: \u092a\u0942\u0930\u094d\u0935-\u092a\u094d\u0930\u0935\u0947\u0936 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915<\/h3>\n\n\n\n<p>\u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0921\u093e\u0932\u0947\u0902 \u0924\u093e\u0915\u093f \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u0938\u0940\u092e\u093f\u0924 \u0939\u094b \u0938\u0915\u0947, \u092b\u093f\u0930 \u0915\u094b\u0930 \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u0947 \u0938\u094d\u0925\u093f\u0930 \u0939\u094b\u0928\u0947 (50\u2013100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0915\u0947 \u092c\u093e\u0926 \u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0930 \u0926\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u0930\u093f\u092a\u0925<\/strong>: \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u0915\u0947 \u0938\u093e\u0925 \u092e\u0941\u0916\u094d\u092f \u092c\u094d\u0930\u0947\u0915\u0930 \u2192 50\u2013100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0926\u0947\u0930\u0940 \u2192 \u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u0915\u094b \u0936\u0949\u0930\u094d\u091f \u0915\u0930\u0924\u093e \u0939\u0948<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915 \u0915\u093e \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923<\/strong>:<br>\u0906\u0930 = \u0935\u0940<sub>\u0936\u093f\u0916\u0930, \u091a\u0930\u092e, \u092a\u0930\u092e, \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u0909\u0924\u094d\u0924\u092e, \u0938\u0930\u094d\u0935\u094b\u091a\u094d\u091a, \u092a\u0930\u092e \u0909\u0924\u094d\u0915\u0930\u094d\u0937, \u092a\u0930<\/sub>\u00a0\/ \u092e\u0948\u0902<sub>\u092a\u094d\u0930\u0935\u093e\u0939,\u0905\u0927\u093f\u0915\u0924\u092e<\/sub><br>12 kV \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0932\u093f\u090f, \u0907\u0928\u0930\u0936 \u0915\u094b 2\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0928\u093e (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, 1000 kVA \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0947 \u0932\u093f\u090f 100 A):<br>R = 16,970 V \/ 100 A =\u00a0<strong>170 \u0913\u092e<\/strong><br>\u0936\u0915\u094d\u0924\u093f \u0930\u0947\u091f\u093f\u0902\u0917: \u0905\u0932\u094d\u092a\u0915\u093e\u0932\u093f\u0915 \u090a\u0930\u094d\u091c\u093e = I\u00b2 \u00d7 R \u00d7 t = (100)\u00b2 \u00d7 170 \u00d7 0.050 =\u00a0<strong>\u096e\u096b \u0915\u093f\u0932\u094b\u091c\u0942\u0932<\/strong><\/p>\n\n\n\n<p><strong>\u0938\u0940\u092e\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u0930\u094d\u0927\u093f\u0924 \u091c\u091f\u093f\u0932\u0924\u093e (\u092c\u093e\u0908\u092a\u093e\u0938 \u0924\u0902\u0924\u094d\u0930, \u0938\u092e\u092f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923)<\/li>\n\n\n\n<li>\u0930\u0947\u091c\u093c\u093f\u0938\u094d\u091f\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u092e\u094b\u0921 \u0913\u092a\u0928-\u0938\u0930\u094d\u0915\u093f\u091f \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f (\u0936\u0949\u0930\u094d\u091f \u0928\u0939\u0940\u0902)\u0964<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-5-sequential-energization-with-delay\">\u0930\u0923\u0928\u0940\u0924\u093f 5: \u0935\u093f\u0932\u0902\u092c \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u0930\u092e\u093f\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u0935\u0930\u094d\u0927\u0928<\/h3>\n\n\n\n<p>\u092e\u0932\u094d\u091f\u0940-\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f, \u090f\u0915 \u092c\u093e\u0930 \u092e\u0947\u0902 \u090f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b 30\u201360 \u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u0905\u0902\u0924\u0930\u093e\u0932 \u092a\u0930 \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0902\u0964 \u092a\u0939\u0932\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0915\u093e \u0905\u0928\u0941\u092d\u0935 \u0915\u0930\u0924\u093e \u0939\u0948; \u092c\u093e\u0926 \u0915\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u094d\u0925\u093f\u0930 \u092c\u0938 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u0947\u0902 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0906\u0932\u094b\u091a\u0928\u093e\u0924\u094d\u092e\u0915<\/strong>: \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u090f\u0915 \u0938\u093e\u0925 \u090a\u0930\u094d\u091c\u093e \u0928 \u0926\u0947\u0902\u2014\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u092a\u094d\u0932\u093f\u0902\u0917 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0902\u092f\u0941\u0915\u094d\u0924 \u0907\u0928\u0930\u0936 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u0947 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0907\u0928\u0930\u0936 \u0915\u093e 1.5 \u0917\u0941\u0928\u093e \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03.webp\" alt=\"\u092a\u093e\u0901\u091a \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e\u0924\u094d\u092e\u0915 \u092e\u0948\u091f\u094d\u0930\u093f\u0915\u094d\u0938 \u091c\u094b \u0932\u093e\u0917\u0924, \u091c\u091f\u093f\u0932\u0924\u093e, \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0914\u0930 \u0926\u094b\u0937 \u0928\u093f\u0935\u093e\u0930\u0923 \u0917\u0924\u093f \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u0940 \u0939\u0948\u0964\" class=\"wp-image-2412\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 3. \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u0923\u0928\u0940\u0924\u093f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e: \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0932\u093e\u0917\u0924-\u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0915\u093e \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0938\u0902\u0924\u0941\u0932\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 (85\u201395% \u0924\u094d\u0930\u093f\u092a\u0932 \u091f\u0949\u092a\u094d\u0932\u0949\u0938 \u0915\u092e\u0940, \u0924\u0947\u091c\u093c \u0926\u094b\u0937 \u0928\u093f\u0935\u093e\u0930\u0923, \u092e\u0927\u094d\u092f\u092e \u0932\u093e\u0917\u0924); \u092a\u0949\u0907\u0902\u091f-\u0911\u0928-\u0935\u0947\u0935 \u0905\u0927\u093f\u0915\u0924\u092e \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0932\u0947\u0915\u093f\u0928 \u0909\u091a\u094d\u091a \u0932\u093e\u0917\u0924 \u092a\u0930; \u091f\u093e\u0907\u092e-\u0921\u093f\u0932\u0947 \u0938\u092c\u0938\u0947 \u0938\u0930\u0932 \u0939\u0948 \u0932\u0947\u0915\u093f\u0928 \u0926\u094b\u0937 \u0928\u093f\u0935\u093e\u0930\u0923 \u0915\u0940 \u0917\u0924\u093f \u0938\u0947 \u0938\u092e\u091d\u094c\u0924\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sympathetic-inrush-when-energizing-one-transformer-trips-others\">\u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f\u0915\u0940 \u0906\u0935\u0947\u0936: \u091c\u092c \u090f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0928\u0947 \u092a\u0930 \u0905\u0928\u094d\u092f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u091f\u094d\u0930\u093f\u092a \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964<\/h2>\n\n\n\n<p>\u091c\u092c \u090f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u091c\u092c\u0915\u093f \u0905\u0928\u094d\u092f \u0909\u0938\u0940 \u092c\u0938 \u092a\u0930 \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u092e \u0915\u0930 \u0930\u0939\u0947 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u092c\u0938 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0917\u093f\u0930\u093e\u0935\u091f \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0917\u093f\u0930\u093e\u0935\u091f \u092a\u0939\u0932\u0947 \u0938\u0947 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u092b\u094d\u0932\u0915\u094d\u0938 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092e\u091c\u092c\u0942\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u2014\u091c\u093f\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u0947 \u091a\u0932 \u0930\u0939\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u201c\u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f\u092a\u0942\u0930\u094d\u0923 \u0907\u0928\u0930\u0936\u201d \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0938\u0902\u092a\u094d\u0930\u0947\u0930\u0915 \u0907\u0928\u0930\u0936 \u0924\u0902\u0924\u094d\u0930<\/strong>:<br>1. \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 A \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u2192 \u092c\u0938 \u0938\u0947 10\u00d7 \u0907\u0928\u0930\u0936 \u0916\u0940\u0902\u091a\u0924\u093e \u0939\u0948<br>2. \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u092e\u0947\u0902 \u0915\u092e\u0940 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092c\u0938 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u0947\u0902 \u0917\u093f\u0930\u093e\u0935\u091f 5-15%<br>3. \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 B \u0914\u0930 C (\u092a\u0939\u0932\u0947 \u0938\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u094d-\u0938\u0902\u091a\u093e\u0930\u093f\u0924) \u091a\u0941\u0902\u092c\u0915\u0940\u092f\u0915\u0930\u0923 \u0927\u093e\u0930\u093e \u0915\u094b \u0915\u094d\u0937\u0924\u093f\u092a\u0942\u0930\u094d\u0924\u093f \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964<br>4. \u0915\u0941\u0932 \u0907\u0928\u0930\u0936 = \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 A \u0907\u0928\u0930\u0936 + \u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f \u0907\u0928\u0930\u0936 (B+C)<br>\u092a\u0930\u093f\u0923\u093e\u092e: \u0938\u0902\u092f\u0941\u0915\u094d\u0924 \u0927\u093e\u0930\u093e \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u093f\u0924 \u0939\u094b\u0928\u0947 \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926 \u0905\u092a\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u092b\u0940\u0921\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0928\u093f\u0935\u093e\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092b\u0940\u0921\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u0930 \u092c\u0938-\u0938\u094d\u0924\u0930 \u0915\u093e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902 (\u0915\u0947\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0928\u0939\u0940\u0902)<\/li>\n\n\n\n<li>\u092b\u0940\u0921\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u093e \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c 1.5\u20132.0 \u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u092c\u0922\u093c\u093e\u090f\u0901\u0964<\/li>\n\n\n\n<li>30\u201360 \u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0926\u0947\u0930\u0940 \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u0930\u092e\u093f\u0915 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u093e<\/li>\n<\/ul>\n\n\n\n<p>40 \u092c\u0939\u0941-\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0926\u093f\u0916\u093e \u0915\u093f \u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f\u092a\u0942\u0930\u094d\u0923 \u0907\u0928\u0930\u0936 \u0928\u0947 \u0915\u0941\u0932 \u0907\u0928\u0930\u0936 \u092a\u0930\u093f\u092e\u093e\u0923 \u092e\u0947\u0902 20\u201340% \u0915\u0940 \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u0940\u2014\u091c\u094b \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u092e\u0928\u094d\u0935\u092f \u092e\u093e\u0930\u094d\u091c\u093f\u0928 \u0935\u093e\u0932\u0947 \u092b\u0940\u0921\u0930\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0925\u093e\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"ats-applications-special-considerations\">\u090f\u091f\u0940\u090f\u0938 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917: \u0935\u093f\u0936\u0947\u0937 \u0935\u093f\u091a\u093e\u0930<\/h2>\n\n\n\n<p>\u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0938\u094d\u0935\u093f\u091a \u092c\u093e\u0930-\u092c\u093e\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u2014\u0938\u093e\u092a\u094d\u0924\u093e\u0939\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930, \u092e\u093e\u0938\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923, \u0914\u0930 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0906\u0909\u091f\u0947\u091c \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0907\u0928\u0930\u0936 \u091f\u094d\u0930\u093f\u092a \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u092c\u0922\u093c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0921\u0947\u0921-\u092c\u0938 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930<\/strong>&nbsp;(\u092a\u0938\u0902\u0926\u0940\u0926\u093e):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u092c\u094d\u0930\u0947\u0915\u0930 \u0916\u094b\u0932\u0947\u0902, 5-10 \u0938\u0947\u0915\u0902\u0921 \u092a\u094d\u0930\u0924\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902 (\u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094d\u0937\u0940\u0923 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948)<\/li>\n\n\n\n<li>\u091c\u0928\u0930\u0947\u091f\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0915\u0930\u0947\u0902 (\u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u2192 \u0915\u092e \u0907\u0928\u0930\u0936)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0932\u093e\u0907\u0935-\u092c\u0938 \u0938\u094d\u0925\u093e\u0928\u093e\u0902\u0924\u0930\u0923<\/strong>&nbsp;(\u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u0938\u094d\u0925\u093f\u0924\u093f):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u092c\u0928\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092c\u094d\u0930\u0947\u0915: \u0915\u094d\u0937\u0923\u093f\u0915 \u0930\u0941\u0915\u093e\u0935\u091f \u2192 \u0909\u091a\u094d\u091a \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092a\u094d\u0930\u0935\u093e\u0939 \u2192 \u0924\u0940\u0935\u094d\u0930 \u0907\u0928\u0930\u0936<\/li>\n\n\n\n<li>\u092c\u094d\u0930\u0947\u0915 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092e\u0947\u0915: \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u2192 \u0915\u094b\u0908 \u0907\u0928\u0930\u0936 \u0928\u0939\u0940\u0902 \u0932\u0947\u0915\u093f\u0928 \u0938\u092e\u0915\u093e\u0932\u093f\u0915\u0924\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u090f\u091f\u0940\u090f\u0938 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0921\u0947\u0921-\u092c\u0938 \u0935\u093f\u0932\u0902\u092c: 5-10 s (\u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u094d\u0937\u092f \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948)<\/li>\n\n\n\n<li>\u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0914\u0930 \u091c\u0928\u0930\u0947\u091f\u0930 \u0926\u094b\u0928\u094b\u0902 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092a\u0930 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0938\u0915\u094d\u0937\u092e\u0964<\/li>\n\n\n\n<li>\u0915\u094d\u0930\u092e\u093f\u0915 \u0932\u094b\u0921 \u092a\u093f\u0915\u0905\u092a (\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u090f\u0915-\u090f\u0915 \u0915\u0930\u0915\u0947 \u091a\u093e\u0932\u0942 \u0915\u0930\u0947\u0902, \u090f\u0915 \u0938\u093e\u0925 \u0928\u0939\u0940\u0902)<\/li>\n<\/ul>\n\n\n\n<p>\u0939\u092e\u0928\u0947 10-\u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0921\u0947\u0921-\u092c\u0938 \u0926\u0947\u0930\u0940 + \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0932\u093e\u0917\u0942 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 ATS-\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u092a\u0930\u0947\u0936\u093e\u0928 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u092f\u093e\u0924\u094d\u0930\u093e\u0913\u0902 \u092e\u0947\u0902 70% \u0915\u0940 \u0915\u092e\u0940 \u092e\u093e\u092a\u0940, \u091c\u092c\u0915\u093f \u0924\u0924\u094d\u0915\u093e\u0932 \u0938\u094d\u0925\u093e\u0928\u093e\u0902\u0924\u0930\u0923 \u0915\u0947 \u0938\u093e\u0925 \u0915\u0947\u0935\u0932 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0940 \u0917\u0908 \u0925\u0940\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"572\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04.webp\" alt=\"\u090f\u091f\u0940\u090f\u0938 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0938\u094d\u0935\u093f\u091a \u092b\u094d\u0932\u094b\u091a\u093e\u0930\u094d\u091f, \u091c\u093f\u0938\u092e\u0947\u0902 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0915\u094b \u0915\u092e \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u094d\u0937\u092f \u0935\u093f\u0932\u0902\u092c \u0915\u0947 \u0938\u093e\u0925 \u0921\u0947\u0921-\u092c\u0938 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u0926\u093f\u0916\u093e\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964\" class=\"wp-image-2414\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04.webp 572w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04-168x300.webp 168w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04-7x12.webp 7w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 4. ATS \u0921\u0947\u0921-\u092c\u0938 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u0907\u0928\u0930\u0936 \u0915\u094b \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u0930\u0924\u093e \u0939\u0948: \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u092c\u094d\u0930\u0947\u0915\u0930 \u0916\u094b\u0932\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 5\u201310 \u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0926\u0947\u0930\u0940 80% \u0938\u0947 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u0947 \u0915\u094d\u0937\u092f \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 &lt;30%, \u091c\u093f\u0938\u0938\u0947 \u092c\u093e\u0926 \u0915\u0947 \u091c\u0928\u0930\u0947\u091f\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0907\u0928\u0930\u0936 \u0915\u094b 10-15\u00d7 \u0938\u0947 \u0918\u091f\u093e\u0915\u0930 3-5\u00d7 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u0915\u0930 \u0926\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-troubleshooting-diagnosing-inrush-vs-genuine-faults\">\u092e\u0948\u0926\u093e\u0928\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923: \u0907\u0928\u0930\u0936 \u092c\u0928\u093e\u092e \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0928\u093f\u0926\u093e\u0928<\/h2>\n\n\n\n<p>\u091c\u092c \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u091f\u094d\u0930\u093f\u092a \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092e\u0942\u0932 \u0915\u093e\u0930\u0923 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<p><strong>\u0907\u0928\u0930\u0936 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901<\/strong>&nbsp;(\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092d\u094c\u0924\u093f\u0915\u0940):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u091f\u094d\u0930\u093f\u092a \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u0915\u0947 100\u2013500 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0939\u094b\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0924\u0930\u0902\u0917 \u0930\u0942\u092a \u0918\u093e\u0924\u0940\u092f \u0915\u094d\u0937\u092f \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 30-70%<\/li>\n\n\n\n<li>30\u201360 \u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u092c\u093e\u0926 \u092a\u0941\u0928\u0903 \u092c\u0902\u0926 \u0915\u0930\u0928\u093e \u0938\u092b\u0932 \u0939\u094b\u0924\u093e \u0939\u0948 (\u0936\u0947\u0937 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u094d\u0937\u0940\u0923 \u0939\u094b \u0917\u092f\u093e)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0926\u094b\u0937 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u092c\u0928\u093e \u0930\u0939\u0924\u093e \u0939\u0948 (\u0915\u094d\u0937\u0940\u0923 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u093e)<\/li>\n\n\n\n<li>\u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 &lt;5%<\/li>\n\n\n\n<li>\u092a\u0941\u0928\u0903 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0935\u093f\u092b\u0932\u0924\u093e (\u0924\u094d\u0930\u0941\u091f\u093f \u0905\u092d\u0940 \u092d\u0940 \u092e\u094c\u091c\u0942\u0926 \u0939\u0948)<\/li>\n\n\n\n<li>\u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u092a\u094d\u0930\u092e\u093e\u0923: \u091c\u0932\u0928\u0947 \u0915\u0940 \u0917\u0902\u0927, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0924\u093f, \u0924\u0947\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0928\u093f\u0926\u093e\u0928 \u0909\u092a\u0915\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u0930\u0915\u094d\u0937\u0923\u093e\u0924\u094d\u092e\u0915 \u0930\u093f\u0932\u0947 \u0938\u0947 \u0907\u0935\u0947\u0902\u091f \u0930\u093f\u0915\u0949\u0930\u094d\u0921\u0930 \u0921\u0947\u091f\u093e (\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0924\u0930\u0902\u0917\u094b\u0902, \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0926\u0947\u0916\u0947\u0902)<\/li>\n\n\n\n<li>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0940\u091f\u0940 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u092a\u0930 \u0911\u0938\u093f\u0932\u094b\u0938\u094d\u0915\u094b\u092a<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u094b\u0937 \u0915\u093e \u0938\u0902\u0926\u0947\u0939 \u0939\u094b \u0924\u094b \u0918\u0941\u0932\u093f\u0924 \u0917\u0948\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 (\u0921\u0940\u091c\u0940\u090f)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092e\u0948\u0926\u093e\u0928\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0947\u0902, 10 \u092e\u093f\u0928\u091f \u092a\u094d\u0930\u0924\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0930\u093f\u0915\u0949\u0930\u094d\u0921\u093f\u0902\u0917 \u0909\u092a\u0915\u0930\u0923 \u091a\u093e\u0932\u0942 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092a\u0941\u0928\u0903 \u090a\u0930\u094d\u091c\u093e\u0935\u093e\u0928 \u092c\u0928\u0947\u0902<\/li>\n\n\n\n<li>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0924\u0930\u0902\u0917 \u0930\u0942\u092a \u0915\u0948\u092a\u094d\u091a\u0930 \u0915\u0930\u0947\u0902 (0-2 \u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li>\u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923: \u0918\u093e\u0924\u0940\u092f \u0915\u094d\u0937\u092f + \u0909\u091a\u094d\u091a \u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 = \u0907\u0928\u0930\u0936; \u0928\u093f\u0930\u0902\u0924\u0930 \u0927\u093e\u0930\u093e + \u0928\u093f\u092e\u094d\u0928 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938 = \u0926\u094b\u0937<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937<\/h2>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u0947\u092f \u092d\u094c\u0924\u093f\u0915 \u0918\u091f\u0928\u093e \u0939\u0948, \u092f\u093e\u0926\u0943\u091a\u094d\u091b\u093f\u0915 \u0909\u092a\u0915\u0930\u0923 \u0935\u093f\u092b\u0932\u0924\u093e \u0928\u0939\u0940\u0902\u0964 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u094b\u0930 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f 8\u201315 \u0917\u0941\u0928\u093e \u0905\u0927\u093f\u0915 \u0927\u093e\u0930\u093e \u0915\u094d\u0937\u0923\u093f\u0915 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948, \u091c\u094b 0.1\u20130.5 \u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902 \u0918\u093e\u0924\u0940\u092f \u0930\u0942\u092a \u0938\u0947 \u0915\u094d\u0937\u0940\u0923 \u0939\u094b\u0924\u0940 \u0939\u0948, \u0914\u0930 \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u0909\u091a\u094d\u091a \u0926\u094d\u0935\u093f\u0924\u0940\u092f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 (30\u201370 \u091f\u0940\u092a\u09403\u091f\u0940 \u092c\u0928\u093e\u092e \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f &lt;51 \u091f\u0940\u092a\u09403\u091f\u0940) \u0926\u094d\u0935\u093e\u0930\u093e \u0905\u0932\u0917 \u092a\u0939\u091a\u093e\u0928\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u091c\u092c \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0907\u0938 \u0905\u0902\u0924\u0930 \u0915\u0940 \u0905\u0928\u0926\u0947\u0916\u0940 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0938\u092d\u0940 \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0926\u094b\u0937 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u093e\u0928 \u0932\u0947\u0924\u093e \u0939\u0948\u2014\u0924\u092c \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u091f\u094d\u0930\u093f\u092a \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092a\u093e\u0901\u091a \u0936\u092e\u0928 \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901 \u0939\u0948\u0902, \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092e\u0947\u0902 \u0932\u093e\u0917\u0924\/\u091c\u091f\u093f\u0932\u0924\u093e \u0915\u093e \u0906\u0926\u093e\u0928-\u092a\u094d\u0930\u0926\u093e\u0928 \u0939\u0948: \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0905\u0924\u093f\u092a\u094d\u0930\u0935\u093e\u0939 (\u0938\u092c\u0938\u0947 \u0938\u0930\u0932 \u0932\u0947\u0915\u093f\u0928 \u0926\u094b\u0937-\u0938\u092e\u093e\u0927\u093e\u0928 \u092e\u0947\u0902 \u0938\u092e\u092f \u091c\u094b\u0921\u093c\u0924\u093e \u0939\u0948), \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 (\u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u0930\u0940\u092f), \u092a\u0949\u0907\u0902\u091f-\u0911\u0928-\u0935\u0947\u0935 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 (\u0938\u092c\u0938\u0947 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0932\u0947\u0915\u093f\u0928 \u092e\u0939\u0902\u0917\u093e), \u092a\u094d\u0930\u0940-\u0907\u0928\u094d\u0938\u0930\u094d\u0936\u0928 \u0930\u0947\u0938\u093f\u0938\u094d\u091f\u0930\u094d\u0938 (\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u092e\u093e\u092e\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f), \u0914\u0930 \u0915\u094d\u0930\u092e\u093f\u0915 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 (\u092c\u0939\u0941-\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902)\u0964 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0907\u0937\u094d\u091f\u0924\u092e \u0938\u0902\u0924\u0941\u0932\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0926\u094b\u0937 \u0928\u093f\u0935\u093e\u0930\u0923 \u092e\u0947\u0902 \u0926\u0947\u0930\u0940 \u0915\u093f\u090f \u092c\u093f\u0928\u093e 85-95% \u0924\u0915 \u0909\u092a\u0926\u094d\u0930\u0935 \u091f\u094d\u0930\u093f\u092a \u092e\u0947\u0902 \u0915\u092e\u0940\u0964.<\/p>\n\n\n\n<p>\u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930\u094d\u0926\u0943\u0937\u094d\u091f\u093f: \u0907\u0928\u0930\u0936 \u090f\u0915 \u0915\u094d\u0937\u0923\u093f\u0915 \u0918\u091f\u0928\u093e \u0939\u0948 \u091c\u093f\u0938\u092e\u0947\u0902 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0932\u0915\u094d\u0937\u0923 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902 (\u0918\u093e\u0924\u0940\u092f \u0915\u094d\u0937\u092f, \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940, \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094d\u0937\u0923 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930\u0924\u093e)\u0964 \u0907\u0928 \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u093e \u0932\u093e\u092d \u0909\u0920\u093e\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092f\u094b\u091c\u0928\u093e\u090f\u0901 \u0938\u093e\u0927\u093e\u0930\u0923 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0913\u0935\u0930\u0915\u0930\u0902\u091f \u0915\u0947 \u0938\u093e\u0925 \u0905\u0938\u0902\u092d\u0935 \u091a\u092f\u0928\u0915\u094d\u0937\u092e\u0924\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964 \u0906\u0927\u0941\u0928\u093f\u0915 \u0930\u093f\u0932\u0947 \u092e\u093e\u0928\u0915 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092e\u093e\u092a\u0928 \u0914\u0930 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u2014\u091c\u093f\u0938\u0938\u0947 \u0930\u093f\u0932\u0947 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u091a\u0915\u094d\u0930\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0932\u093e\u0917\u0924 \u092a\u0930 \u0907\u0928\u0930\u0936 \u0935\u093f\u092d\u0947\u0926\u0928 \u0938\u0902\u092d\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0909\u091a\u093f\u0924 \u0938\u092e\u0928\u094d\u0935\u092f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u091f\u094d\u0930\u093f\u092a \u0939\u094b\u0928\u0947 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0938\u0947 \u0928\u093f\u092f\u092e\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u092e\u0947\u0902 \u092c\u0926\u0932 \u0926\u0947\u0924\u093e \u0939\u0948\u2014\u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u092e\u0947\u0902 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0918\u093f\u0938\u093e\u0935 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948, \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u094d\u092e\u091a\u093e\u0930\u093f\u092f\u094b\u0902 \u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0916\u0930\u093e\u092c\u0940 \u0926\u0942\u0930 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u0915\u094d\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u092c\u091c\u093e\u092f \u0909\u0928 \u0915\u093e\u0932\u094d\u092a\u0928\u093f\u0915 \u201c\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902\u201d \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0928\u0947 \u0915\u0947 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u092d\u0940 \u0926\u094b\u0939\u0930\u093e \u0928\u0939\u0940\u0902 \u092a\u093e\u0924\u093e\u0964.<\/p>\n\n\n\n<p>\u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0935\u093f\u0935\u0930\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0907\u0938 \u092e\u0947\u0902 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094d\u0937\u092e\u0924\u093e\u0913\u0902 \u0915\u093e \u0915\u094d\u0930\u0949\u0938-\u091a\u0947\u0915 \u0915\u0930\u0947\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker-ratings\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0947\u091f\u093f\u0902\u0917 \u0917\u093e\u0907\u0921<\/a>&nbsp;\u0914\u0930 \u0915\u0947 \u0938\u093e\u0925 \u090a\u0937\u094d\u092e\u0940\u092f \u092d\u093e\u0930 \u092e\u093e\u0928\u094d\u092f\u0924\u093e\u0913\u0902 \u0915\u094b \u092e\u093e\u0928\u094d\u092f \u0915\u0930\u0947\u0902&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/transformer-cooling-classes-onan-onaf-ofaf-guide\/\">\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0942\u0932\u093f\u0902\u0917 \u0915\u094d\u0932\u093e\u0938 \u0938\u0902\u0926\u0930\u094d\u092d<\/a>.<\/p>\n\n\n\n<p><strong>\u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u0926\u0930\u094d\u092d:<\/strong> \u0907\u0928\u0930\u0936 \u0935\u094d\u092f\u0935\u0939\u093e\u0930 \u0938\u0947 \u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0915\u094b\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u0940 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901 \u092e\u0947\u0902 \u092e\u093e\u0928\u0915\u0940\u0915\u0943\u0924 \u0915\u0940 \u0917\u0908 \u0939\u0948\u0902\u0964&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/599\" target=\"_blank\" rel=\"noopener\">\u0906\u0908\u0908\u0938\u0940 60076 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-transformer-inrush--nuisance-trips\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928: \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0914\u0930 \u0905\u0935\u093e\u0902\u091b\u093f\u0924 \u091f\u094d\u0930\u093f\u092a<\/h2>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 1: \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f 8\u201315 \u0917\u0941\u0928\u093e \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f \u0924\u0915 \u0915\u094d\u092f\u094b\u0902 \u092a\u0939\u0941\u0901\u091a \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f\u0915\u0930\u0923 \u0927\u093e\u0930\u093e \u0915\u0947\u0935\u0932 0.5\u20132% \u0939\u094b\u0924\u0940 \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u0938\u094d\u0925\u093f\u0930-\u0905\u0935\u0938\u094d\u0925\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u091a\u0941\u092e\u094d\u092c\u0915\u0915\u0930\u0923 \u0927\u093e\u0930\u093e B-H \u0935\u0915\u094d\u0930 \u0915\u0947 \u0930\u0948\u0916\u093f\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930\u0924\u0940 \u0939\u0948 \u091c\u0939\u093e\u0901 \u0915\u094b\u0930 \u092a\u093e\u0930\u0917\u092e\u094d\u092f\u0924\u093e \u0905\u0927\u093f\u0915 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0909\u091a\u094d\u091a \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092b\u094d\u0932\u0915\u094d\u0938 (\u0936\u093f\u0916\u0930 \u0915\u093e 60-80%) \u0915\u0947 \u0938\u093e\u0925 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u0942\u0928\u094d\u092f-\u092a\u093e\u0930 \u0939\u094b\u0928\u0947 \u092a\u0930 \u090a\u0930\u094d\u091c\u093e-\u092a\u094d\u0930\u0935\u093e\u0939 \u0915\u0941\u0932 \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u094b 1.8 p.u. \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u093e \u0926\u0947\u0924\u093e \u0939\u0948\u2014\u091c\u094b 1.2-1.3 p.u. \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u0938\u0940\u092e\u093e \u0938\u0947 \u0915\u0939\u0940\u0902 \u0905\u0927\u093f\u0915 \u0939\u0948\u0964 \u0938\u0948\u091a\u0941\u0930\u0947\u0936\u0928 \u092e\u0947\u0902, \u092a\u093e\u0930\u0917\u092e\u094d\u092f\u0924\u093e \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0906\u0935\u0936\u094d\u092f\u0915 \u092b\u094d\u0932\u0915\u094d\u0938 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0917\u0948\u0930-\u0930\u0947\u0916\u0940\u092f B-H \u0938\u0902\u092c\u0902\u0927 \u092d\u093e\u0930\u0940 \u0927\u093e\u0930\u093e \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092a\u0940\u0915 \u0907\u0928\u0930\u0936 = V_\u0932\u093e\u0917\u0942 \/ (X_\u092e\u0948\u0917\u094d\u0928\u0947\u091f\u093e\u0907\u091c\u093f\u0902\u0917_\u0938\u0948\u091a\u0941\u0930\u0947\u091f\u0947\u0921), \u091c\u0939\u093e\u0901 \u0938\u0948\u091a\u0941\u0930\u0947\u091f\u0947\u0921 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0936\u0940\u0932\u0924\u093e \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0947 10-20\u00d7 \u0915\u092e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u0935\u093f\u0924\u0930\u0923 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 8-15\u00d7 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0935\u0943\u0926\u094d\u0927\u093f \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u0947 \u0938\u094d\u0925\u093f\u0930 \u0939\u094b\u0928\u0947 \u0914\u0930 \u0915\u094b\u0930 \u0915\u0947 \u0938\u0948\u091a\u0941\u0930\u0947\u0936\u0928 \u0938\u0947 \u092c\u093e\u0939\u0930 \u0928\u093f\u0915\u0932\u0928\u0947 \u0924\u0915 100-500 ms \u0924\u0915 \u092c\u0928\u0940 \u0930\u0939\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q2: \u0926\u094d\u0935\u093f\u0924\u0940\u092f-\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u0915\u094b \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0926\u094b\u0937\u094b\u0902 \u0938\u0947 \u0915\u0948\u0938\u0947 \u0905\u0932\u0917 \u0915\u0930\u0924\u093e \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0907\u0928\u0930\u0936 \u092e\u0947\u0902 30\u201370 \u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0915\u0940 \u0926\u0942\u0938\u0930\u0940 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 (50 \u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 100 \u0939\u0930\u094d\u091f\u094d\u091c\u093c) \u0939\u094b\u0924\u0940 \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0915\u094b\u0930 \u0938\u0948\u091a\u0941\u0930\u0947\u0936\u0928 \u0905\u0938\u092e\u092e\u093f\u0924 \u092b\u094d\u0932\u0915\u094d\u0938 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u090f\u0915 \u0905\u0930\u094d\u0927-\u091a\u0915\u094d\u0930 \u092e\u0947\u0902 \u092d\u093e\u0930\u0940 \u0938\u0948\u091a\u0941\u0930\u0947\u0936\u0928 \u091c\u092c\u0915\u093f \u0926\u0942\u0938\u0930\u0947 \u092e\u0947\u0902 \u0930\u0948\u0916\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0924\u0930\u0902\u0917\u0930\u0942\u092a \u0905\u0938\u092e\u092e\u093f\u0924\u0924\u093e \u0938\u092e \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0926\u094b\u0937 \u0932\u0917\u092d\u0917 \u0938\u093e\u0907\u0928\u0941\u0938\u094b\u0907\u0921\u0932 \u0927\u093e\u0930\u093e \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 (&gt;95% \u092e\u0942\u0932 \u0906\u0935\u0943\u0924\u094d\u0924\u093f, 15-20% \u0939\u0948, \u0924\u094b \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u0907\u0928\u0930\u0936 (inrush) \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0935\u0930\u094d\u0917\u0940\u0915\u0943\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 0.5-1.0 \u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093f\u092a\u093f\u0902\u0917 \u0915\u094b \u0905\u0935\u0930\u0941\u0926\u094d\u0927 \u0915\u0930 \u0926\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0916\u093e\u092e\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 &lt;5% \u0915\u093e \u0905\u0928\u0941\u092a\u093e\u0924 \u0939\u094b\u0924\u093e \u0939\u0948, \u0907\u0938\u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u092b\u0940\u0932\u094d\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u0924\u093e \u0939\u0948 \u0915\u093f \u0915\u0947\u0935\u0932 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0915\u0947 \u0938\u093e\u0925 85-95% \u0924\u0915 \u0915\u0940 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u091f\u094d\u0930\u093f\u092a \u092e\u0947\u0902 \u0915\u092e\u0940 \u0906\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q3: \u0938\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0915\u0941\u091b \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0905\u0928\u094d\u092f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0907\u0928\u0930\u0936 \u0915\u0930\u0902\u091f \u0905\u0927\u093f\u0915 \u0915\u094d\u092f\u094b\u0902 \u0939\u094b\u0924\u093e \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u0907\u0928\u0930\u0936 \u0915\u0940 \u0917\u0902\u092d\u0940\u0930\u0924\u093e \u0915\u094b \u091b\u0939 \u0915\u093e\u0930\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902: (1) \u0915\u094b\u0930 \u0938\u093e\u092e\u0917\u094d\u0930\u0940\u2014CRGO \u0938\u093f\u0932\u093f\u0915\u0949\u0928 \u0938\u094d\u091f\u0940\u0932 60-80% \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092b\u094d\u0932\u0915\u094d\u0938 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948 (\u0916\u0930\u093e\u092c \u0907\u0928\u0930\u0936) \u092c\u0928\u093e\u092e 30-50% \u092a\u0930 \u0905\u0915\u094d\u0930\u093f\u0938\u094d\u091f\u0932\u0940\u092f \u0927\u093e\u0924\u0941 (\u092c\u0947\u0939\u0924\u0930); (2) \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u093e \u0906\u0915\u093e\u0930\u2014\u092c\u0921\u093c\u0947 \u0907\u0915\u093e\u0907\u092f\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u0924\u093f-\u0907\u0915\u093e\u0908 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948, \u0915\u094d\u0937\u092f \u0938\u092e\u092f \u0938\u094d\u0925\u093f\u0930\u093e\u0902\u0915 \u0932\u0902\u092c\u0947 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902; (3) \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e\u2014\u0915\u0920\u094b\u0930 \u0938\u094d\u0930\u094b\u0924 \u0909\u091a\u094d\u091a \u0936\u093f\u0916\u0930 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u0915\u092e\u091c\u094b\u0930 \u0938\u094d\u0930\u094b\u0924 \u0906\u092f\u093e\u092e \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0932\u0947\u0915\u093f\u0928 \u0905\u0935\u0927\u093f \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u0947 \u0939\u0948\u0902; (4) \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u094b\u0923\u2014\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u0940\u0930\u094b-\u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 \u0938\u092c\u0938\u0947 \u0916\u0930\u093e\u092c \u0938\u094d\u0925\u093f\u0924\u093f (\u0905\u0938\u092e\u093e\u0928 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939) \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u093e \u0939\u0948, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0940\u0915 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0907\u0928\u0930\u0936 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u093e \u0939\u0948; (5) \u0932\u094b\u0921 \u0915\u093e \u0907\u0924\u093f\u0939\u093e\u0938\u2014\u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u0940\u0915\u0930\u0923 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092d\u093e\u0930\u0940 \u0932\u094b\u0921 \u0935\u093e\u0932\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0905\u0927\u093f\u0915 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902; (6) \u092a\u093f\u091b\u0932\u093e \u0935\u093f\u0930\u093e\u092e\u2014\u0915\u0930\u0902\u091f-\u0936\u0942\u0928\u094d\u092f \u092a\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 (80%) \u0915\u094b \u0905\u0927\u093f\u0915\u0924\u092e \u0915\u0930\u0924\u093e \u0939\u0948, \u092f\u093e\u0926\u0943\u091a\u094d\u091b\u093f\u0915 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 30-80% \u0924\u0915 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q4: \u0915\u094c\u0928 \u0938\u0940 \u092a\u094d\u0930\u094b\u091f\u0947\u0915\u094d\u0936\u0928 \u0930\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u092c\u093f\u0928\u093e \u0926\u094b\u0937 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u092e\u0947\u0902 \u0938\u092e\u091d\u094c\u0924\u093e \u0915\u093f\u090f \u0907\u0928\u0930\u0936 \u0928\u0941\u0907\u0938\u0947\u0902\u0938 \u091f\u094d\u0930\u093f\u092a \u0915\u094b \u0930\u094b\u0915\u0924\u0940 \u0939\u0948\u0902?<\/strong><\/p>\n\n\n\n<p>\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 (\u092a\u0938\u0902\u0926\u0940\u0926\u093e): 15-18% \u0925\u094d\u0930\u0947\u0936\u094b\u0932\u094d\u0921 \u092a\u0930 \u0926\u094d\u0935\u093f\u0924\u0940\u092f-\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092c\u094d\u0932\u0949\u0915\u093f\u0902\u0917 \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0947\u0902 (SEL \u0930\u093f\u0932\u0947 \u092a\u0930 PCT2 = 18%, ABB \u092a\u0930 50H \u0938\u0947\u091f\u093f\u0902\u0917)\u0964 \u0921\u093f\u092b\u0930\u0947\u0902\u0936\u093f\u092f\u0932 \u092a\u093f\u0915\u0905\u092a \u0915\u094b 0.25 pu (87P = 0.25) \u092a\u0930 \u0938\u0947\u091f \u0915\u0930\u0947\u0902, \u0938\u094d\u0932\u094b\u092a \u0915\u094b 35% (87S = 35%) \u092a\u0930 \u0938\u0947\u091f \u0915\u0930\u0947\u0902\u0964 \u0907\u0938\u0938\u0947 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0932\u093f\u090f &lt;100 ms \u092e\u0947\u0902 \u0924\u0941\u0930\u0902\u0924 \u092b\u0949\u0932\u094d\u091f \u0915\u094d\u0932\u093f\u092f\u0930\u093f\u0902\u0917 \u0939\u094b\u0924\u0940 \u0939\u0948, \u0938\u093e\u0925 \u0939\u0940 \u0907\u0928\u0930\u0936 \u091f\u094d\u0930\u093f\u092a \u0915\u094b \u092c\u094d\u0932\u0949\u0915 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0909\u092a\u0932\u092c\u094d\u0927 \u0928\u0939\u0940\u0902 \u0939\u0948, \u0924\u094b 1.3-1.5\u00d7 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0915\u0940 \u0930\u0947\u091f\u0947\u0921 \u0927\u093e\u0930\u093e \u092a\u0930 \u092a\u093f\u0915\u0905\u092a \u0915\u0947 \u0938\u093e\u0925 0.8-1.2 \u0938\u0947\u0915\u0902\u0921 \u0915\u093e \u0928\u093f\u0936\u094d\u091a\u093f\u0924-\u0938\u092e\u092f \u0935\u093f\u0932\u0902\u092c (definite-time delay) \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u2014\u092f\u0939 \u092b\u0949\u0932\u094d\u091f-\u0915\u094d\u0932\u093f\u092f\u0930\u093f\u0902\u0917 \u0917\u0924\u093f \u0915\u094b \u0907\u0928\u0930\u0936 \u092a\u094d\u0930\u0924\u093f\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u092c\u0926\u0932 \u0926\u0947\u0924\u093e \u0939\u0948\u0964 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 (\u090f\u091f\u0940\u090f\u0938, \u0932\u094b\u0921 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930) \u0915\u0947 \u0932\u093f\u090f \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0939\u0948; \u0915\u0947\u0935\u0932 \u0938\u092e\u092f-\u0935\u093f\u0932\u0902\u092c (time-delay) \u0935\u093f\u0932\u0902\u092c \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u092b\u0949\u0932\u094d\u091f \u091c\u094b\u0916\u093f\u092e \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q5: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 \u0907\u0928\u0930\u0936 \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092a\u0949\u0907\u0902\u091f-\u0911\u0928-\u0935\u0947\u0935 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/strong><\/p>\n\n\n\n<p>\u092a\u0949\u0907\u0902\u091f-\u0911\u0928-\u0935\u0947\u0935 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0936\u093f\u0916\u0930 \u092a\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0915\u0930\u0915\u0947 \u0907\u0928\u0930\u0936 85\u201395% \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 (\u0938\u092e\u0924\u0941\u0932\u094d\u092f \u092b\u094d\u0932\u0915\u094d\u0938 \u0938\u0902\u091a\u092f, \u0915\u094b\u0908 \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u0928\u0939\u0940\u0902)\u0964 \u0905\u0935\u0936\u093f\u0937\u094d\u091f \u092b\u094d\u0932\u0915\u094d\u0938 \u0905\u092a\u094d\u0930\u093e\u0938\u0902\u0917\u093f\u0915 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0932\u093e\u0917\u0942 \u092b\u094d\u0932\u0915\u094d\u0938 \u0936\u0942\u0928\u094d\u092f \u0938\u0947 \u0936\u0941\u0930\u0942 \u0939\u094b\u0915\u0930 \u0938\u092e\u092e\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0905\u0927\u093f\u0915\u0924\u092e \u00b11.0 p.u. \u0924\u0915 \u092c\u0922\u093c\u0924\u093e \u0939\u0948\u2014\u091c\u094b 1.2 p.u. \u0938\u0902\u0924\u0943\u092a\u094d\u0924\u093f \u0938\u0940\u092e\u093e \u0938\u0947 \u0915\u093e\u092b\u0940 \u0928\u0940\u091a\u0947 \u0939\u0948\u0964 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901: (1) \u090f\u0915 \u0938\u092e\u093e\u0928 \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u091f\u093e\u0907\u092e \u0935\u093e\u0932\u093e VCB (\u00b12 ms \u092a\u0941\u0928\u0930\u093e\u0935\u0943\u0924\u094d\u0924\u093f, \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u092c\u0947\u0939\u0924\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0924\u0902\u0924\u094d\u0930); (2) \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092b\u0947\u091c \u0915\u094b \u092e\u093e\u092a\u0928\u0947 \u0935\u093e\u0932\u093e \u0938\u093f\u0902\u0915\u094d\u0930\u094b\u0928\u0938 \u0915\u0902\u091f\u094d\u0930\u094b\u0932\u0930; (3) \u092a\u094d\u0930\u0924\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u0932\u093e\u0917\u0924 5,000-15,000 \u0930\u0941\u092a\u092f\u0947\u0964 \u092f\u0939 \u092c\u0921\u093c\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 (&gt;5 MVA), \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 (\u0926\u0948\u0928\u093f\u0915 \u091a\u0915\u094d\u0930), \u092f\u093e \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0932\u094b\u0921 \u0915\u0947 \u0932\u093f\u090f \u0938\u092c\u0938\u0947 \u0905\u091a\u094d\u091b\u093e \u0939\u0948 \u091c\u094b \u0907\u0928\u0930\u0936 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0917\u093f\u0930\u093e\u0935\u091f \u0915\u094b \u092c\u0930\u094d\u0926\u093e\u0936\u094d\u0924 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u0947\u0964 \u0915\u092e \u092c\u093e\u0930 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u091b\u094b\u091f\u0947 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092f\u0939 \u0932\u093e\u0917\u0924-\u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u0928\u0939\u0940\u0902 \u0939\u0948\u2014\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 10% \u0938\u0947 \u0915\u092e \u0932\u093e\u0917\u0924 \u092a\u0930 90%+ \u0915\u093e \u0932\u093e\u092d \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 6: \u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f\u0917\u0924 \u0907\u0928\u0930\u0936 \u0915\u094d\u092f\u093e \u0939\u0948 \u0914\u0930 \u092f\u0939 \u0915\u092c \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u093e \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u0938\u0902\u092a\u094d\u0930\u0947\u0930\u0915 \u0907\u0928\u0930\u0936 \u0924\u092c \u0939\u094b\u0924\u093e \u0939\u0948 \u091c\u092c \u090f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0928\u0947 \u092a\u0930 \u092a\u0939\u0932\u0947 \u0938\u0947 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0938\u092e\u093e\u0928\u093e\u0902\u0924\u0930 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0927\u093e\u0930\u093e \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964   \u0915\u093e\u0930\u094d\u092f\u0935\u093f\u0927\u093f:   \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 A \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0926\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948 \u2192 10 \u0917\u0941\u0928\u093e \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e \u2192 \u0938\u094d\u0930\u094b\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0915\u0947 \u0915\u093e\u0930\u0923 \u092c\u0938 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u0947\u0902 5\u201315% \u0915\u0940 \u0917\u093f\u0930\u093e\u0935\u091f \u2192 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 B \u0914\u0930 C (\u091c\u094b \u092a\u0939\u0932\u0947 \u0938\u0947 \u091a\u0932 \u0930\u0939\u0947 \u0939\u0948\u0902) \u0915\u094b \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0917\u093f\u0930\u093e\u0935\u091f \u0915\u0940 \u092d\u0930\u092a\u093e\u0908 \u0914\u0930 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0927\u093e\u0930\u093e \u092c\u0922\u093c\u093e\u0928\u0940 \u092a\u0921\u093c\u0924\u0940 \u0939\u0948\u0964 \u0915\u0941\u0932 \u092c\u0938 \u0907\u0928\u0930\u0936 = \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0907\u0928\u0930\u0936 (A) + \u0938\u0939\u093e\u0928\u0941\u092d\u0942\u0924\u093f\u092a\u0942\u0930\u094d\u0923 \u0907\u0928\u0930\u0936 (B+C), \u091c\u094b \u0905\u0915\u094d\u0938\u0930 \u0915\u0947\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 A \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0928\u0947 \u0915\u0947 \u0907\u0928\u0930\u0936 \u0915\u093e 1.2-1.5 \u0917\u0941\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0905\u092a\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u092b\u0940\u0921\u0930 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948, \u092d\u0932\u0947 \u0939\u0940 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u093f\u0924 \u0939\u094b\u0964 \u0928\u093f\u0935\u093e\u0930\u0923: \u092b\u0940\u0921\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u0930 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902, \u091f\u093e\u0907\u092e-\u0921\u093f\u0932\u0947 \u0915\u094b 1.5-2.0 \u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u092c\u0922\u093c\u093e\u090f\u0901, \u092f\u093e 30-60 \u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0926\u0947\u0930\u0940 \u0915\u0947 \u0938\u093e\u0925 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u093e\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u094b \u0915\u094d\u0930\u092e\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q7: \u092e\u0948\u0902 \u0915\u0948\u0938\u0947 \u092a\u0924\u093e \u0932\u0917\u093e\u090a\u0901 \u0915\u093f \u0915\u094b\u0908 \u091f\u094d\u0930\u093f\u092a \u0907\u0928\u0930\u0936 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u0941\u0906 \u0939\u0948 \u092f\u093e \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930 \u0926\u094b\u0937 \u0915\u0947 \u0915\u093e\u0930\u0923?<\/strong><\/p>\n\n\n\n<p>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0924\u0930\u0902\u0917\u0930\u0942\u092a \u0914\u0930 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0918\u091f\u0928\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0940 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902:&nbsp;<strong>\u0907\u0928\u0930\u0936 \u0938\u093f\u0917\u094d\u0928\u0947\u091a\u0930<\/strong>&nbsp;100\u2013500 ms \u092e\u0947\u0902 \u0918\u093e\u0924\u0940\u092f \u0915\u094d\u0937\u092f, 30\u201370% \u0938\u0947\u0915\u0902\u0921-\u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915 \u0938\u093e\u092e\u0917\u094d\u0930\u0940, \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092a\u0939\u0932\u0947 500 ms \u0915\u0947 \u092d\u0940\u0924\u0930 \u091f\u094d\u0930\u093f\u092a, 30\u201360 s \u0915\u0940 \u0926\u0947\u0930\u0940 \u0915\u0947 \u092c\u093e\u0926 \u0938\u092b\u0932 \u092a\u0941\u0928\u0903\u092c\u0902\u0926 (\u092b\u094d\u0932\u0915\u094d\u0938 \u0915\u094d\u0937\u0940\u0923)\u0964.&nbsp;<strong>\u0924\u094d\u0930\u0941\u091f\u093f \u0939\u0938\u094d\u0924\u093e\u0915\u094d\u0937\u0930<\/strong>&nbsp;\u0932\u0917\u093e\u0924\u093e\u0930 \u0915\u0930\u0902\u091f \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948 (\u0915\u094b\u0908 \u0915\u094d\u0937\u092f \u0928\u0939\u0940\u0902), 1000 M\u03a9 \u0938\u093e\u092e\u093e\u0928\u094d\u092f), \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0918\u0941\u0932\u093f\u0924 \u0917\u0948\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 (DGA), \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p>","protected":false},"excerpt":{"rendered":"<p>Transformer energization creates the most common nuisance trip condition in medium-voltage distribution systems. The magnetic core must establish flux when voltage is applied, and if switching occurs near voltage zero-crossing, the flux waveform becomes asymmetric\u2014driving the core into deep saturation. Magnetizing current skyrockets from its normal 0.5-2% of rated load to 8-15\u00d7 transformer full-load current, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2411,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-2409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2409"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2409\/revisions"}],"predecessor-version":[{"id":3562,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2409\/revisions\/3562"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2411"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2409"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}