{"id":2425,"date":"2026-01-04T05:56:04","date_gmt":"2026-01-04T05:56:04","guid":{"rendered":"https:\/\/xbrele.com\/?p=2425"},"modified":"2026-04-07T13:47:11","modified_gmt":"2026-04-07T13:47:11","slug":"vcb-timing-test-travel-curves-interruption-reliability","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/vcb-timing-test-travel-curves-interruption-reliability\/","title":{"rendered":"\u0935\u0940\u0938\u0940\u092c\u0940 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930: \u0930\u0941\u0915\u093e\u0935\u091f \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u093e"},"content":{"rendered":"<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 (\u0935\u0940\u0938\u0940\u092c\u0940) \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923, \u0916\u094b\u0932\u0928\u0947 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u094b \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902\u2014\u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093f\u0924\u0928\u0940 \u0924\u0947\u091c\u0940 \u0938\u0947 \u091a\u0932\u0924\u0947 \u0939\u0948\u0902, \u0915\u094d\u092f\u093e \u0917\u0924\u093f \u0938\u0941\u091a\u093e\u0930\u0942 \u0939\u0948, \u0914\u0930 \u0915\u094d\u092f\u093e \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0924\u093e \u0939\u0948\u0964 \u092f\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u0939 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094d\u0937\u0924\u093f \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0926\u094b\u0937\u092a\u0942\u0930\u094d\u0923 \u0927\u093e\u0930\u093e \u0915\u094b \u0930\u094b\u0915 \u0938\u0915\u0924\u093e \u0939\u0948, \u0915\u093f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935 \u0928\u0947 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u0915\u092e\u091c\u094b\u0930 \u0928\u0939\u0940\u0902 \u0915\u093f\u092f\u093e \u0939\u0948, \u0914\u0930 \u0915\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0938\u0902\u092c\u0902\u0927\u0940 \u092e\u093e\u0928\u094d\u092f\u0924\u093e\u090f\u0901 \u092e\u093e\u0928\u094d\u092f \u092c\u0928\u0940 \u0939\u0941\u0908 \u0939\u0948\u0902\u0964 40 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921 \u090f\u0915 \u0935\u0940\u0938\u0940\u092c\u0940, \u091c\u094b \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 60 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u092c\u093f\u0917\u0921\u093c \u091c\u093e\u0924\u093e \u0939\u0948, \u092c\u0948\u0915\u0905\u092a \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u091f\u094d\u0930\u093f\u092a \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0926\u0942\u0930 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0935\u093f\u092b\u0932 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0938\u092e\u0928\u094d\u0935\u092f \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u093e\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 \u091f\u094d\u0930\u0948\u0935\u0932 \u0915\u0930\u094d\u0935 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u092f\u0939 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0915\u094d\u092f\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0920\u0940\u0915 \u0938\u0947 \u0924\u094d\u0935\u0930\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0915\u094d\u092f\u093e \u0921\u0948\u0936\u092a\u0949\u091f\u094d\u0938 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0939\u0948\u0902, \u0914\u0930 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u094d\u0928\u0947\u0939\u0928 \u092f\u093e \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0915\u092c \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u092e\u0938\u094d\u092f\u093e \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u092f\u093e \u0906\u0935\u0927\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u094d\u0930\u0915\u091f \u0939\u094b\u0924\u0940 \u0939\u0948: \u0906\u092a \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u091f\u0947\u0938\u094d\u091f \u0938\u0947\u091f \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091f\u094d\u0930\u093f\u092a \u091f\u094d\u0930\u093f\u0917\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u0911\u0938\u093f\u0932\u094b\u0938\u094d\u0915\u094b\u092a \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0915\u094b \u0930\u0947\u091f\u0947\u0921 35 ms \u0915\u0947 \u092c\u091c\u093e\u092f 50 ms \u092a\u0930 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964 \u0915\u094d\u092f\u093e \u092f\u0939 \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0935\u093f\u091a\u0932\u0928 \u0939\u0948 \u092f\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u092a\u094d\u0930\u092e\u093e\u0923? \u0915\u094d\u092f\u093e \u092f\u0939 \u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948? \u0915\u094d\u092f\u093e \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094b \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u092f\u093e \u0924\u0941\u0930\u0902\u0924 \u0913\u0935\u0930\u0939\u0949\u0932 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f? \u092c\u093f\u0928\u093e \u0938\u092e\u091d \u0915\u0947 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"noopener\">\u0906\u0908\u0908\u0938\u0940 62271-100<\/a> \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u091f\u0949\u0932\u0930\u0947\u0902\u0938, \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901, \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930\u094b\u0902 \u0924\u0925\u093e \u0930\u0941\u0915\u093e\u0935\u091f \u092d\u094c\u0924\u093f\u0915\u0940 \u0915\u0947 \u092c\u0940\u091a \u0938\u0902\u092c\u0902\u0927 \u0915\u094b \u0927\u094d\u092f\u093e\u0928 \u092e\u0947\u0902 \u0930\u0916\u0947 \u092c\u093f\u0928\u093e, \u0906\u092a \u092f\u0939 \u0928\u093f\u0930\u094d\u0923\u092f \u0928\u0939\u0940\u0902 \u0932\u0947 \u0938\u0915\u0924\u0947\u2014\u091c\u093f\u0938\u0938\u0947 \u092f\u093e \u0924\u094b \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e (\u0915\u093e\u0930\u094d\u092f\u0936\u0940\u0932 \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u094b \u0939\u091f\u093e\u0928\u093e) \u092f\u093e \u0938\u0947\u0935\u093e \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 (\u0916\u0930\u093e\u092c \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u094b \u0911\u0928\u0932\u093e\u0907\u0928 \u0930\u0916\u0928\u093e) \u0915\u093e \u091c\u094b\u0916\u093f\u092e \u0939\u094b\u0917\u093e\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e VCB \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902, IEC \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0915\u0940 \u0935\u094d\u092f\u093e\u0916\u094d\u092f\u093e, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0935\u093f\u091a\u0932\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0935\u093f\u0927\u093f\u092f\u094b\u0902, \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0924\u0925\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0930\u0941\u0915\u093e\u0935\u091f \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0947 \u092c\u0940\u091a \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u092c\u0902\u0927 \u0915\u094b \u0938\u092e\u091d\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0935\u0940\u0938\u0940\u092c\u0940 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930: \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u092b\u0940\u0932\u094d\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/9AU5AGaDwtY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-opening-time-affects-interruption-capability\">\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u0935\u093f\u0918\u091f\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u094b \u0915\u094d\u092f\u094b\u0902 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948<\/h2>\n\n\n\n<p>\u0924\u094d\u0930\u0941\u091f\u093f \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902, VCB \u0915\u094b \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0928\u093e \u0914\u0930 \u0906\u0930\u094d\u0915 \u0915\u094b \u092c\u0941\u091d\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0907\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u093f: (1) \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0915\u094b \u0915\u094d\u0937\u0924\u093f \u092a\u0939\u0941\u0901\u091a\u093e\u090f, \u092f\u093e (2) \u0924\u093e\u092a\u0940\u092f \u0924\u0928\u093e\u0935 \u0938\u093f\u0930\u0947\u092e\u093f\u0915 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0947\u0964 IEC 62271-100 \u092e\u0947\u0902 \u0905\u0927\u093f\u0915\u0924\u092e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 30\u201350 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948, \u0924\u093e\u0915\u093f \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u092a\u0930 \u092f\u0947 \u0938\u0940\u092e\u093e\u090f\u0901 \u092a\u093e\u0930 \u0928 \u0939\u094b\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0938\u092e\u092f \u0918\u091f\u0915 \u0916\u094b\u0932\u0947\u0902<\/strong>:<br>t<sub>\u0916\u0941\u0932\u093e<\/sub>\u00a0\u092c\u0930\u093e\u092c\u0930 \u0939\u0948<sub>\u0930\u093f\u0939\u093e\u0908<\/sub>\u00a0+ \u091f\u0940<sub>\u0938\u0902\u092a\u0930\u094d\u0915<\/sub>\u00a0+ \u091f\u0940<sub>\u091a\u093e\u092a<\/sub><br><br>\u2022\u00a0<strong>t<sub>\u0930\u093f\u0939\u093e\u0908<\/sub><\/strong>: \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0938\u0915\u094d\u0930\u093f\u092f \u0939\u094b\u0924\u0940 \u0939\u0948 \u2192 \u0932\u0948\u091a \u0930\u093f\u0932\u0940\u091c\u093c \u0939\u094b\u0924\u093e \u0939\u0948 (5-15 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<br>\u2022\u00a0<strong>t<sub>\u0938\u0902\u092a\u0930\u094d\u0915<\/sub><\/strong>: \u0938\u0902\u092a\u0930\u094d\u0915 \u0939\u093f\u0932\u0928\u093e \u0936\u0941\u0930\u0942 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u2192 \u092a\u0942\u0930\u094d\u0923 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 (15-30 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<br>\u2022\u00a0<strong>t<sub>\u091a\u093e\u092a<\/sub><\/strong>\u0906\u0930\u094d\u0915 \u0906\u0930\u0902\u092d \u2192 \u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0936\u0942\u0928\u094d\u092f \u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 + \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f (5-10 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<br>\u0915\u0941\u0932: \u0938\u093e\u092e\u093e\u0928\u094d\u092f 12 kV \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f 25-55 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921<\/p>\n\n\n\n<p><strong>\u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u091a\u092f<\/strong>12 kV \u092a\u0930 25 kA \u0915\u093e \u0926\u094b\u0937 \u092a\u094d\u0930\u0924\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u0932\u0917\u092d\u0917 50 kW \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f 35 ms \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 50 ms \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e 1.75 kJ \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 2.5 kJ (+43%) \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u2014\u091c\u094b \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923 \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u094b \u092a\u093e\u0930 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u092e\u092f\u092a\u0942\u0930\u094d\u0935 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>IEC 62271-100 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0938\u092e\u092f \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e<\/strong>\u0905\u0927\u093f\u0915\u0924\u092e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u2264 \u0930\u0947\u091f\u0947\u0921 \u092e\u093e\u0928 + 10%\u0964 40 ms \u0930\u0947\u091f\u0947\u0921 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0932\u093f\u090f 44 ms \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948; 48 ms \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0902\u091a \u0914\u0930 \u0938\u0902\u092d\u0935\u0924\u0903 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0938\u092e\u091d\u0928\u093e&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/what-is-vacuum-circuit-breaker-working-principle\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0948\u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902<\/a>&nbsp;\u092f\u0939 \u092c\u0924\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u092e\u092f-\u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0930\u0941\u0915\u093e\u0935\u091f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u0938\u0940\u0927\u0947 \u0915\u094d\u092f\u094b\u0902 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01.webp\" alt=\"\u0938\u092e\u092f \u0905\u0902\u0924\u0930\u093e\u0932\u094b\u0902 \u0938\u0939\u093f\u0924 \u0935\u0940\u0938\u0940\u092c\u0940 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0905\u0928\u0941\u0915\u094d\u0930\u092e\u2014\u0924\u0940\u0928-\u091a\u0930\u0923 \u091f\u094d\u0930\u093f\u092a \u0930\u093f\u0932\u0940\u091c\u093c, \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0914\u0930 \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f \u0926\u093f\u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u0938\u092e\u092f\u0930\u0947\u0916\u093e \u0906\u0930\u0947\u0916\" class=\"wp-image-2428\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 1. VCB \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0905\u0928\u0941\u0915\u094d\u0930\u092e \u0938\u092e\u092f\u0930\u0947\u0916\u093e: \u091f\u094d\u0930\u093f\u092a \u0930\u093f\u0932\u0940\u091c (5\u201315 ms), \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 (15\u201330 ms), \u0914\u0930 \u0906\u0930\u094d\u0915 \u0905\u0935\u0927\u093f (5\u201310 ms), \u0915\u0941\u0932 25\u201355 ms\u0964 IEC 62271-100 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0924\u093e \u0939\u0948 \u0915\u093f \u0905\u0927\u093f\u0915\u0924\u092e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u2264 \u0930\u0947\u091f\u0947\u0921 \u092e\u093e\u0928 + 10% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u0924\u093e\u0915\u093f \u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u092a\u0930 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0940\u092e\u093f\u0924 \u0939\u094b \u0938\u0915\u0947\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact-travel-curve-anatomy-interpreting-position-vs-time\">\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0938\u0902\u0930\u091a\u0928\u093e: \u0938\u094d\u0925\u093f\u0924\u093f \u092c\u0928\u093e\u092e \u0938\u092e\u092f \u0915\u0940 \u0935\u094d\u092f\u093e\u0916\u094d\u092f\u093e<\/h2>\n\n\n\n<p>\u090f\u0915 \u091f\u094d\u0930\u0948\u0935\u0932 \u0935\u0915\u094d\u0930 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u092f\u093e \u0938\u092e\u093e\u092a\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0924\u093f (\u0932\u0902\u092c\u0935\u0924 \u0905\u0915\u094d\u0937, \u092e\u093f\u092e\u0940) \u092c\u0928\u093e\u092e \u0938\u092e\u092f (\u0915\u094d\u0937\u0948\u0924\u093f\u091c \u0905\u0915\u094d\u0937, \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948\u0964 \u0935\u0915\u094d\u0930 \u0915\u093e \u0906\u0915\u093e\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0938\u0941\u091a\u093e\u0930\u0942 \u0924\u094d\u0935\u0930\u0923 \u0909\u091a\u093f\u0924 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0932 \u0914\u0930 \u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948; \u0905\u091a\u093e\u0928\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u092c\u093e\u0907\u0902\u0921\u093f\u0902\u0917, \u0918\u093f\u0938\u093e\u0935, \u092f\u093e \u0921\u0948\u0936\u092a\u0949\u091f \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092e\u0941\u0916\u094d\u092f \u0935\u0915\u094d\u0930 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0935\u093f\u0930\u093e\u092e<\/strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0930 \u0930\u0939\u0924\u0947 \u0939\u0948\u0902 \u091c\u092c \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0932\u0948\u091a \u0930\u093f\u0932\u0940\u091c\u093c \u0939\u094b\u0924\u093e \u0939\u0948 (0-10 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li><strong>\u0924\u094d\u0935\u0930\u0923 \u091a\u0930\u0923<\/strong>\u0935\u0938\u0902\u0924 \u0916\u0941\u0932\u0928\u0947 \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0924\u093e \u0939\u0948, \u0917\u0924\u093f \u092c\u0922\u093c\u0924\u0940 \u0939\u0948 (10-20 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li><strong>\u0938\u094d\u0925\u093f\u0930 \u0935\u0947\u0917<\/strong>: \u0905\u0927\u093f\u0915\u0924\u092e \u0917\u0924\u093f \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0939\u094b \u0917\u0908, \u0921\u0948\u0936\u092a\u0949\u091f \u0905\u092d\u0940 \u0924\u0915 \u0938\u0915\u094d\u0930\u093f\u092f \u0928\u0939\u0940\u0902 \u0939\u0941\u0906 (20-30 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li><strong>\u0917\u0924\u093f \u092e\u0947\u0902 \u0915\u092e\u0940<\/strong>\u0921\u0948\u0936\u092a\u0949\u091f \u090a\u0930\u094d\u091c\u093e \u0905\u0935\u0936\u094b\u0937\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u0947 \u0905\u0902\u0924 \u092e\u0947\u0902 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091d\u091f\u0915\u0947 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 (30-40 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li><strong>\u0905\u0902\u0924\u093f\u092e \u0938\u094d\u0925\u093f\u0924\u093f<\/strong>: \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0916\u0941\u0932\u0947, \u0921\u0948\u0936\u092a\u0949\u091f \u0938\u0902\u0915\u0941\u091a\u093f\u0924, \u0917\u0924\u093f \u0930\u0941\u0915\u0924\u0940 \u0939\u0948 (40-45 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0906\u092e 12 kV VCB \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/strong>:<br>\u2022\u00a0<strong>\u0915\u0941\u0932 \u0938\u094d\u091f\u094d\u0930\u094b\u0915<\/strong>: 10-14 \u092e\u093f\u092e\u0940 (\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0926\u0942\u0930\u0940)<br>\u2022\u00a0<strong>\u091a\u0930\u092e \u0935\u0947\u0917<\/strong>: 0.8-1.2 \u092e\u0940\/\u0938\u0947 (60-70% \u0938\u094d\u091f\u094d\u0930\u094b\u0915 \u092a\u0930 \u092a\u094d\u0930\u093e\u092a\u094d\u0924)<br>\u2022\u00a0<strong>\u0914\u0938\u0924 \u0935\u0947\u0917<\/strong>: 0.5-0.7 \u092e\u0940\/\u0938\u0947 (\u0938\u094d\u091f\u094d\u0930\u094b\u0915 \/ \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0938\u092e\u092f)<br>\u2022\u00a0<strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0938\u0902\u0932\u0917\u094d\u0928\u0924\u093e<\/strong>: \u0938\u094d\u091f\u094d\u0930\u094b\u0915 \u0915\u0947 \u0905\u0902\u0924\u093f\u092e 20-30%<br>IEC 62271-100 \u0938\u091f\u0940\u0915 \u092e\u093e\u0928 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u093e\u2014\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0906\u0930\u094d\u0915 \u0905\u0935\u0930\u094b\u0927\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0935\u0915\u094d\u0930 \u0935\u093f\u091a\u0932\u0928<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0927\u0940\u092e\u0940 \u0924\u094d\u0935\u0930\u0923<\/strong>\u0915\u092e\u091c\u094b\u0930 \u0936\u0941\u0930\u0941\u0906\u0924\u0940 \u0935\u0938\u0902\u0924 (\u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e)<\/li>\n\n\n\n<li><strong>\u0935\u0947\u0917 \u092e\u0947\u0902 \u0909\u091b\u093e\u0932<\/strong>\u0932\u093f\u0902\u0915\u0947\u091c \u092e\u0947\u0902 \u091c\u0915\u0921\u093c\u0928 (\u0938\u094d\u0928\u0947\u0939\u0928 \u092f\u093e \u0938\u0902\u0930\u0947\u0916\u0923 \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e)<\/li>\n\n\n\n<li><strong>\u0915\u094b\u0908 \u0921\u0948\u0936\u092a\u0949\u091f \u092e\u0902\u0926\u0928 \u0928\u0939\u0940\u0902<\/strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0924\u0930\u0932 \u0930\u093f\u0938\u093e\u0935, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091d\u091f\u0915\u0947 \u0938\u0947 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/li>\n\n\n\n<li><strong>\u0918\u091f\u093e \u0939\u0941\u0906 \u0938\u094d\u091f\u094d\u0930\u094b\u0915<\/strong>: \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0942\u0930\u094d\u0923 \u0930\u0942\u092a \u0938\u0947 \u0916\u0941\u0932\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0924\u0915 \u0928\u0939\u0940\u0902 \u092a\u0939\u0941\u0901\u091a \u0930\u0939\u0947 \u0939\u0948\u0902 (\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0926\u0942\u0930\u0940 \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924)<\/li>\n<\/ul>\n\n\n\n<p>10\u201320 \u0935\u0930\u094d\u0937 \u092a\u0941\u0930\u093e\u0928\u0947 120 VCBs \u0915\u0947 \u092b\u0940\u0932\u094d\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 25% \u092e\u0947\u0902 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u094d\u0937\u0930\u0923 (\u0915\u094b\u0908 \u0926\u0943\u0936\u094d\u092f\u092e\u093e\u0928 \u092e\u0902\u0926\u0940 \u0928\u0939\u0940\u0902), 15% \u092e\u0947\u0902 \u0938\u094d\u091f\u094d\u0930\u094b\u0915 \u092e\u0947\u0902 \u0915\u092e\u0940 (&lt;90% \u0930\u0947\u091f\u0947\u0921), \u0914\u0930 8% \u092e\u0947\u0902 IEC +10% \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u093e\u0908 \u0917\u0908\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02.webp\" alt=\"\u0924\u0941\u0932\u0928\u093e\u0924\u094d\u092e\u0915 \u0917\u094d\u0930\u093e\u092b\u093c \u091c\u094b \u0938\u093e\u092e\u093e\u0928\u094d\u092f VCB \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 (\u0938\u094d\u092e\u0942\u0925 S-\u0906\u0915\u093e\u0930) \u0915\u094b \u0915\u094d\u0937\u092f\u093f\u0924 \u0935\u0915\u094d\u0930 (\u0927\u0940\u092e\u0940 \u0924\u094d\u0935\u0930\u0923, \u092c\u093f\u0928\u093e \u0921\u0948\u0936\u092a\u0949\u091f \u0914\u0930 \u0915\u092e \u0938\u094d\u091f\u094d\u0930\u094b\u0915) \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0924\u093e \u0939\u0948\u0964\" class=\"wp-image-2430\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 2. \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e: \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0935\u0915\u094d\u0930 (\u092c\u093e\u090f\u0901) 1.0 \u092e\u0940\/\u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u0936\u093f\u0916\u0930 \u0935\u0947\u0917 \u0924\u0915 \u0938\u0941\u091a\u093e\u0930\u0942 \u0924\u094d\u0935\u0930\u0923 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948 \u091c\u093f\u0938\u092e\u0947\u0902 \u0921\u0948\u0936\u092a\u0949\u091f \u0926\u094d\u0935\u093e\u0930\u093e \u092e\u0902\u0926\u0940 \u0938\u094d\u092a\u0937\u094d\u091f \u0939\u0948; \u0915\u094d\u0937\u092f\u093f\u0924 \u0935\u0915\u094d\u0930 (\u0926\u093e\u090f\u0901) \u0927\u0940\u092e\u093e \u0924\u094d\u0935\u0930\u0923 (\u0915\u092e\u091c\u094b\u0930 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917), \u0935\u0947\u0917 \u092e\u0947\u0902 \u0909\u091b\u093e\u0932 (\u0938\u0902\u092f\u094b\u091c\u0928 \u0905\u091f\u0915\u0928), \u092e\u0902\u0926\u0940 \u0915\u093e \u0905\u092d\u093e\u0935 (\u0921\u0948\u0936\u092a\u0949\u091f \u0926\u094d\u0930\u0935 \u0930\u093f\u0938\u093e\u0935), \u0914\u0930 \u0915\u092e \u0905\u0902\u0924\u093f\u092e \u0938\u094d\u091f\u094d\u0930\u094b\u0915 (&lt;90% \u0930\u0947\u091f\u0947\u0921)\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-test-procedure-equipment-and-measurement\">\u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e: \u0909\u092a\u0915\u0930\u0923 \u0914\u0930 \u092e\u093e\u092a\u0928<\/h2>\n\n\n\n<p>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093f\u092a\/\u0915\u094d\u0932\u094b\u091c\u093c \u0915\u0949\u0907\u0932\u094d\u0938 \u092e\u0947\u0902 \u0921\u0940\u0938\u0940 \u0915\u0930\u0902\u091f \u0907\u0902\u091c\u0947\u0915\u094d\u091f \u0915\u0930\u0928\u0947, \u0938\u0939\u093e\u092f\u0915 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u092f\u093e \u0930\u0948\u0916\u093f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u093e\u092a\u0928\u0947, \u0914\u0930 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0938\u0947\u0915\u0902\u0921 \u0938\u0902\u0915\u0932\u094d\u092a \u0915\u0947 \u0938\u093e\u0925 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0935\u0940\u0938\u0940\u092c\u0940 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0915<\/strong>\u00a0(\u0913\u092e\u093f\u0915\u094d\u0930\u0949\u0928 CB-1, \u092e\u0947\u0917\u0930 EZCT-2000, \u0921\u094b\u092c\u0932 TDR-500): \u0921\u0940\u0938\u0940 \u0938\u092a\u094d\u0932\u093e\u0908, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u093e\u092a\u0928, \u091f\u094d\u0930\u0948\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u0907\u0902\u091f\u0930\u092b\u093c\u0947\u0938 \u0915\u0947 \u0938\u093e\u0925 \u090f\u0915\u0940\u0915\u0943\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947\u091f<\/li>\n\n\n\n<li><strong>\u092f\u093e\u0924\u094d\u0930\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930<\/strong>: \u091a\u0932\u0924\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0936\u093e\u092b\u094d\u091f \u0938\u0947 \u091c\u0941\u0921\u093c\u093e \u0930\u0948\u0916\u093f\u0915 \u092a\u094b\u091f\u0947\u0902\u0936\u093f\u092f\u094b\u092e\u0940\u091f\u0930 \u092f\u093e \u0911\u092a\u094d\u091f\u093f\u0915\u0932 \u090f\u0928\u094d\u0915\u094b\u0921\u0930 (\u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0902\u0915\u0947\u0924 \u092e\u0947\u0902 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948)<\/li>\n\n\n\n<li><strong>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u092e\u092f\u0928<\/strong>\u092e\u094c\u091c\u0942\u0926\u093e \u092c\u094d\u0930\u0947\u0915\u0930 \u0938\u0939\u093e\u092f\u0915 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0902\u0926\u0930\u094d\u092d \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u0930\u0924\u093e \u0939\u0948 (\u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u092e \u0938\u091f\u0940\u0915 \u0932\u0947\u0915\u093f\u0928 \u0915\u093f\u0938\u0940 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u0932\u0917\u094d\u0928\u0924\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u091a\u0930\u0923-\u0926\u0930-\u091a\u0930\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-1-safety-and-preparation-10-minutes\">\u091a\u0930\u0923 1: \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0924\u0948\u092f\u093e\u0930\u0940 (10 \u092e\u093f\u0928\u091f)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u093e\u0939\u0930 \u0928\u093f\u0915\u093e\u0932\u093e \u0917\u092f\u093e \u0939\u0948, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0939\u091f\u093e \u0926\u0940 \u0917\u0908 \u0939\u0948, \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0915\u0930 \u0926\u093f\u090f \u0917\u090f \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u091f\u094d\u0930\u0948\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u0915\u094b \u091a\u0932\u0924\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0936\u093e\u092b\u094d\u091f \u0938\u0947 \u0938\u0902\u0932\u0917\u094d\u0928 \u0915\u0930\u0947\u0902 (\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902)<\/li>\n\n\n\n<li>\u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0915\u0947 \u0921\u0940\u0938\u0940 \u0906\u0909\u091f\u092a\u0941\u091f \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0938\u0947 \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902 (\u0927\u094d\u0930\u0941\u0935\u0940\u092f\u0924\u093e \u0915\u093e \u0927\u094d\u092f\u093e\u0928 \u0930\u0916\u0947\u0902)<\/li>\n\n\n\n<li>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0907\u0928\u092a\u0941\u091f\u094d\u0938 \u0915\u094b \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0938\u0947 \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902 (\u090f\u0928\u0913 \u0914\u0930 \u090f\u0928\u0938\u0940 \u0938\u0902\u092a\u0930\u094d\u0915)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-2-initial-trip-test-5-minutes\">\u091a\u0930\u0923 2: \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (5 \u092e\u093f\u0928\u091f)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932\u0940 \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0930\u0947\u091f\u0947\u0921 \u0921\u0940\u0938\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0947 \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f (\u0915\u094b\u0907\u0932 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e\u0935\u093e\u0928 \u0939\u094b\u0928\u0947 \u0915\u093e \u0915\u094d\u0937\u0923 \u2192 \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928)<\/li>\n\n\n\n<li>\u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0915\u0948\u092a\u094d\u091a\u0930 \u0915\u0930\u0947\u0902 (0-100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0935\u093f\u0902\u0921\u094b \u092e\u0947\u0902 \u0938\u094d\u0925\u093f\u0924\u093f \u092c\u0928\u093e\u092e \u0938\u092e\u092f)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092a\u093e\u0938 \u0939\u094b\u0928\u0947 \u0915\u0947 \u092e\u093e\u0928\u0926\u0902\u0921<\/strong>: \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u2264 \u0930\u0947\u091f\u0947\u0921 + 10%, \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u091a\u093f\u0915\u0928\u093e \u0914\u0930 \u0926\u0943\u0936\u094d\u092f\u092e\u093e\u0928 \u0921\u0948\u0936\u092a\u0949\u091f \u092e\u0902\u0926\u0928 \u0915\u0947 \u0938\u093e\u0925<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-3-voltage-variation-test-15-minutes\">\u091a\u0930\u0923 3: \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (15 \u092e\u093f\u0928\u091f)<\/h3>\n\n\n\n<p>\u0930\u0947\u091f\u0947\u0921 \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 80%, 100% \u0914\u0930 110% \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964 IEC 62271-100 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 70\u2013110% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u0938\u092b\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u092a\u0947\u0915\u094d\u0937\u093f\u0924 \u0938\u092e\u092f-\u0935\u093f\u0935\u093f\u0927\u0924\u093e<\/strong>:<br>\u2022 110% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930: \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f 5-10% \u0924\u0915 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 (\u092e\u091c\u092c\u0942\u0924 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092c\u0932, \u0924\u0947\u091c\u093c \u0932\u0948\u091a \u0930\u093f\u0932\u0940\u091c\u093c)<br>\u2022 80% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930: \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f 10-15% \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948 (\u0915\u092e\u091c\u094b\u0930 \u092c\u0932, \u0927\u0940\u092e\u0940 \u0930\u093f\u0939\u093e\u0908)<br>\u2022 70% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930: \u091f\u094d\u0930\u093f\u092a \u0939\u094b\u0928\u0947 \u092e\u0947\u0902 \u0935\u093f\u092b\u0932 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948 (\u0932\u0948\u091a \u091b\u094b\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u092c\u0932)<br>\u092f\u0926\u093f \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0940\u092e\u093e \u092e\u0947\u0902 20% \u0938\u0947 \u0905\u0927\u093f\u0915 \u092d\u093f\u0928\u094d\u0928\u0924\u093e \u0939\u094b, \u0924\u094b \u0915\u0949\u0907\u0932 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092f\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091c\u0915\u0921\u093c\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-4-close-operation-test-5-minutes\">\u091a\u0930\u0923 4: \u0911\u092a\u0930\u0947\u0936\u0928 \u091f\u0947\u0938\u094d\u091f \u092c\u0902\u0926 \u0915\u0930\u0947\u0902 (5 \u092e\u093f\u0928\u091f)<\/h3>\n\n\n\n<p>\u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0926\u094b\u0939\u0930\u093e\u090f\u0901\u0964 \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0915\u093e \u0938\u092e\u092f \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0913\u092a\u0928\u093f\u0902\u0917 \u0938\u0947 \u0924\u0947\u091c\u093c \u0939\u094b\u0924\u093e \u0939\u0948 (20\u201335 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921), \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0905\u0927\u093f\u0915 \u092e\u091c\u092c\u0942\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u2014\u0907\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u0914\u0930 \u0915\u0902\u092a\u094d\u0930\u0947\u0936\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u094b \u092a\u093e\u0930 \u0915\u0930\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-5-multi-operation-test-30-minutes\">\u091a\u0930\u0923 5: \u092c\u0939\u0941-\u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (30 \u092e\u093f\u0928\u091f)<\/h3>\n\n\n\n<p>30-\u0938\u0947\u0915\u0902\u0921 \u0915\u0947 \u0905\u0902\u0924\u0930\u093e\u0932 \u092a\u0930 10 \u0932\u0917\u093e\u0924\u093e\u0930 \u0916\u094b\u0932\u0928\u0947-\u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0947 \u091a\u0915\u094d\u0930 \u0915\u0930\u0947\u0902\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u094d\u0930\u093f\u092f\u093e \u0915\u093e \u0938\u092e\u092f \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0915\u094d\u0937\u0930\u0923 \u0938\u0902\u0915\u0947\u0924\u0915<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>10 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092e\u0947\u0902 5 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0935\u093f\u091a\u0932\u0928: \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u094d\u0928\u0947\u0939\u0928 \u0928\u0939\u0940\u0902 (\u0918\u0930\u094d\u0937\u0923 \u092c\u0922\u093c \u0930\u0939\u093e \u0939\u0948)<\/li>\n\n\n\n<li>\u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0915\u093e \u0906\u0915\u093e\u0930 \u092c\u0926\u0932\u0928\u093e: \u0921\u0948\u0936\u092a\u0949\u091f \u0935\u093e\u0930\u094d\u092e\u093f\u0902\u0917 (\u0926\u094d\u0930\u0935 \u0915\u0940 \u091a\u093f\u092a\u091a\u093f\u092a\u093e\u0939\u091f \u092e\u0947\u0902 \u0915\u092e\u0940)<\/li>\n<\/ul>\n\n\n\n<p>\u0935\u094d\u092f\u093e\u092a\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0926\u0947\u0916\u0947\u0902&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vcb-fat-sat-acceptance-test-checklist\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u092b\u0948\u091f\/\u0938\u0948\u091f \u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03.webp\" alt=\"\u0935\u0940\u0938\u0940\u092c\u0940 \u092b\u0940\u0932\u094d\u0921 \u091f\u0947\u0938\u094d\u091f \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0921\u093e\u092f\u0917\u094d\u0930\u093e\u092e \u091c\u094b \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0915\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u094b \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0915\u0947 \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0914\u0930 \u091f\u094d\u0930\u0948\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u0938\u0947 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964\" class=\"wp-image-2427\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 3. \u092b\u0940\u0932\u094d\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923 \u0938\u0947\u091f\u0905\u092a: VCB \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 (\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f DC \u0906\u092a\u0942\u0930\u094d\u0924\u093f), \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 (\u0938\u092e\u092f \u0938\u0902\u0926\u0930\u094d\u092d\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f) \u0914\u0930 \u091f\u094d\u0930\u0948\u0935\u0932 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 (\u0938\u094d\u0925\u093f\u0924\u093f \u092e\u093e\u092a\u0928 \u0915\u0947 \u0932\u093f\u090f) \u0938\u0947 \u091c\u0941\u0921\u093c\u093e \u0939\u0948\u0964 IEC 62271-100 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 80%, 100% \u0914\u0930 110% \u0930\u0947\u091f\u0947\u0921 \u091f\u094d\u0930\u093f\u092a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093f\u090f \u0917\u090f\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"troubleshooting-timing-deviations-root-causes-and-fixes\">\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0935\u093f\u091a\u0932\u0928\u094b\u0902 \u0915\u093e \u0928\u093f\u0935\u093e\u0930\u0923: \u092e\u0942\u0932 \u0915\u093e\u0930\u0923 \u0914\u0930 \u0938\u092e\u093e\u0927\u093e\u0928<\/h2>\n\n\n\n<p>\u091c\u092c \u092e\u093e\u092a\u093e \u0917\u092f\u093e \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b, \u0924\u094b \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0928\u093f\u0926\u093e\u0928 \u092f\u0939 \u092a\u0939\u091a\u093e\u0928\u0924\u093e \u0939\u0948 \u0915\u093f \u0938\u092e\u0938\u094d\u092f\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u0921\u0948\u0936\u092a\u0949\u091f\u094d\u0938, \u0938\u094d\u0928\u0947\u0939\u0928), \u0935\u093f\u0926\u094d\u092f\u0941\u0924 (\u0915\u094b\u0907\u0932 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0932\u0948\u091a \u092e\u0948\u0917\u094d\u0928\u0947\u091f) \u092f\u093e \u0938\u092e\u093e\u092f\u094b\u091c\u0928-\u0938\u0902\u092c\u0902\u0927\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0928\u093f\u0926\u093e\u0928 \u0928\u093f\u0930\u094d\u0923\u092f \u0935\u0943\u0915\u094d\u0937<\/strong>:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-1-opening-time-10-20-slower-than-rated\">\u0932\u0915\u094d\u0937\u0923 1: \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u0930\u0947\u091f\u0947\u0921 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 10-20% \u0927\u0940\u092e\u093e<\/h3>\n\n\n\n<p><strong>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0915\u092e\u091c\u094b\u0930 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0935\u0938\u0902\u0924<\/strong>: \u0906\u092f\u0941\/\u0925\u0915\u093e\u0928 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0935\u0938\u0902\u0924 \u0924\u0928\u093e\u0935 \u0915\u092e \u0939\u094b \u0917\u092f\u093e\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0938\u0902\u092a\u0940\u0921\u093c\u0928 \u0915\u094b \u092b\u094b\u0930\u094d\u0938 \u0917\u0947\u091c \u0938\u0947 \u092e\u093e\u092a\u0947\u0902 (\u0921\u0947\u091f\u093e\u0936\u0940\u091f \u00b110% \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f)<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>: \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u092c\u0926\u0932\u0947\u0902<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u092c\u0922\u093c\u093e \u0939\u0941\u0906 \u0918\u0930\u094d\u0937\u0923<\/strong>: \u0938\u0942\u0916\u0947 \u092a\u093f\u0935\u091f \u092f\u093e \u0926\u0942\u0937\u093f\u0924 \u0932\u093f\u0902\u0915\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>\u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932\u0940 \u0938\u093e\u0907\u0915\u093f\u0932 \u092c\u094d\u0930\u0947\u0915\u0930, \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0915\u094b \u092e\u0939\u0938\u0942\u0938 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0938\u093e\u092b \u0915\u0930\u0947\u0902 \u0914\u0930 \u092a\u0941\u0928\u0903 \u091a\u093f\u0915\u0928\u093e\u0908 \u0932\u0917\u093e\u090f\u0901 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092e\u094b\u0932\u093f\u092c\u094d\u0921\u0947\u0928\u092e \u0921\u093e\u0907\u0938\u0932\u094d\u092b\u093e\u0907\u0921 \u0917\u094d\u0930\u0940\u0938)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0913\u0935\u0930-\u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917<\/strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0926\u094d\u0930\u0935 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u091a\u093f\u092a\u091a\u093f\u092a\u093e (\u0917\u0932\u0924 \u092a\u094d\u0930\u0915\u093e\u0930 \u092f\u093e \u0920\u0902\u0921\u0947 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0947 \u0915\u093e\u0930\u0923)\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>\u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u092e\u0902\u0926\u0940 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948 (\u0921\u0948\u0936\u092a\u0949\u091f \u092c\u0939\u0941\u0924 \u091c\u0932\u094d\u0926\u0940 \u0938\u0915\u094d\u0930\u093f\u092f \u0939\u094b \u0930\u0939\u093e \u0939\u0948)<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0924\u0930\u0932 \u0915\u094b \u0938\u0939\u0940 \u091a\u093f\u092a\u091a\u093f\u092a\u093e\u092a\u0928 \u0917\u094d\u0930\u0947\u0921 \u0938\u0947 \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-2-opening-time-varies-15-between-operations\">\u0932\u0915\u094d\u0937\u0923 2: \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092c\u0940\u091a \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u092e\u0947\u0902 &gt;15% \u092d\u093f\u0928\u094d\u0928\u0924\u093e<\/h3>\n\n\n\n<p><strong>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0932\u0948\u091a \u0918\u093f\u0938\u093e\u0935<\/strong>: \u091f\u094d\u0930\u093f\u092a \u0932\u0948\u091a \u0915\u0940 \u0938\u0924\u0939 \u0918\u093f\u0938\u0940 \u0939\u0941\u0908, \u0930\u093f\u0932\u0940\u091c\u093c \u092a\u0949\u0907\u0902\u091f \u0905\u0938\u0902\u0917\u0924\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>: \u0917\u0921\u094d\u0922\u0947 \u092f\u093e \u0935\u093f\u0915\u0943\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>: \u0932\u0948\u091a \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u092c\u0926\u0932\u0947\u0902<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0915\u094b\u0907\u0932 \u0939\u0940\u091f\u093f\u0902\u0917<\/strong>\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0922\u093c\u0928\u093e\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>: \u0915\u0949\u0907\u0932 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0920\u0902\u0921\u093e \u0914\u0930 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u092a\u0930 \u092e\u093e\u092a\u0947\u0902 (\u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 &lt;15% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f)<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>\u092f\u0926\u093f &gt;20% \u092d\u093f\u0928\u094d\u0928\u0924\u093e \u0939\u094b, \u0924\u094b \u0915\u0949\u0907\u0932 \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-3-travel-curve-shows-no-dashpot-deceleration\">\u0932\u0915\u094d\u0937\u0923 3: \u091f\u094d\u0930\u0948\u0935\u0932 \u0935\u0915\u094d\u0930 \u092e\u0947\u0902 \u0921\u0948\u0936\u092a\u0949\u091f \u092e\u0902\u0926\u0928 \u0928\u0939\u0940\u0902 \u0926\u093f\u0916\u0924\u093e<\/h3>\n\n\n\n<p><strong>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0924\u0930\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935<\/strong>\u092a\u093f\u0938\u094d\u091f\u0928 \u0938\u0940\u0932 \u092b\u0947\u0932 \u0939\u094b \u0917\u0908, \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0916\u094b \u0917\u0908\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0924\u0947\u0932 \u0915\u0947 \u0905\u0935\u0936\u0947\u0937\u094b\u0902 \u0915\u093e \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>\u0928\u090f \u0938\u0940\u0932 \u0914\u0930 \u0926\u094d\u0930\u0935 \u0915\u0947 \u0938\u093e\u0925 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u093e \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0921\u0948\u0936\u092a\u0949\u091f \u0938\u092e\u093e\u092f\u094b\u091c\u0928 \u0917\u0932\u0924<\/strong>: \u092a\u093f\u0938\u094d\u091f\u0928 \u0920\u0940\u0915 \u0938\u0947 \u091c\u0941\u0921\u093c \u0928\u0939\u0940\u0902 \u0930\u0939\u093e \u0939\u0948\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>: \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u090f\u0902\u0917\u0947\u091c\u092e\u0947\u0902\u091f \u0938\u094d\u0925\u093f\u0924\u093f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0924\u0940 \u0939\u0948<\/li>\n\n\n\n<li><strong>\u0920\u0940\u0915 \u0915\u0930\u0947\u0902<\/strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0948\u0928\u0941\u0905\u0932 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u092e\u092f-\u0938\u0902\u0936\u094b\u0927\u0928 \u092c\u0928\u093e\u092e \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0928\u093f\u0930\u094d\u0923\u092f<\/strong>:<br>\u2022\u00a0<strong>\u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong>: 80\u2013110% \u0930\u0947\u091f\u0947\u0921 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0938\u092e\u092f-\u0938\u0940\u092e\u093e, \u0938\u0902\u091a\u093e\u0932\u0928 \u092e\u0947\u0902 \u0938\u0941\u0938\u0902\u0917\u0924, \u092e\u093e\u092e\u0942\u0932\u0940 \u0938\u094d\u0928\u0947\u0939\u0928 \u0906\u0935\u0936\u094d\u092f\u0915<br>\u2022\u00a0<strong>\u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0928\u093e<\/strong>: \u091f\u093e\u0907\u092e\u093f\u0902\u0917 110-125% \u0930\u0947\u091f\u0947\u0921, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\/\u0921\u0948\u0936\u092a\u0949\u091f \u092e\u0947\u0902 \u0917\u093f\u0930\u093e\u0935\u091f \u0932\u0947\u0915\u093f\u0928 \u0915\u094b\u0908 \u0938\u0902\u0930\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0915\u094d\u0937\u0924\u093f \u0928\u0939\u0940\u0902<br>\u2022\u00a0<strong>\u092c\u0926\u0932\u0947\u0902<\/strong>: \u091f\u093e\u0907\u092e\u093f\u0902\u0917 &gt;125% \u0930\u0947\u091f\u0947\u0921, \u0915\u0908 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 + \u0932\u0948\u091a + \u0938\u0902\u092a\u0930\u094d\u0915), \u092f\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092b\u094d\u0930\u0948\u0915\u094d\u091a\u0930<\/p>\n\n\n\n<p>85 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 70% \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0935\u093f\u091a\u0932\u0928 \u0938\u094d\u0928\u0947\u0939\u0928 \u0914\u0930 \u0921\u0948\u0936\u092a\u0949\u091f \u0938\u0947\u0935\u093e \u0938\u0947 \u0920\u0940\u0915 \u0939\u0941\u090f, 20% \u092e\u0947\u0902 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0925\u0940, \u0914\u0930 10% \u092e\u0947\u0902 \u092a\u0942\u0930\u0947 \u0924\u0902\u0924\u094d\u0930 \u0915\u093e \u092a\u0942\u0930\u094d\u0923 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u0915\u0930\u0928\u093e \u092a\u0921\u093c\u093e\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"relationship-between-closing-time-and-contact-bounce\">\u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u091f\u093e\u0907\u092e \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f \u092c\u093e\u0909\u0902\u0938 \u0915\u0947 \u092c\u0940\u091a \u0938\u0902\u092c\u0902\u0927<\/h2>\n\n\n\n<p>\u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0911\u092a\u0930\u0947\u0936\u0902\u0938 \u0915\u094b \u0928 \u0915\u0947\u0935\u0932 \u0930\u0947\u091f\u0947\u0921 \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u091f\u093e\u0907\u092e (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 20\u201335 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0939\u093e\u0938\u093f\u0932 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u092c\u0932\u094d\u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u0915\u094b \u092d\u0940 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u2014\u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u0915\u0947 \u092c\u093e\u0926 \u0917\u0924\u093f\u091c \u090a\u0930\u094d\u091c\u093e \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u093e \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923\u0964 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u092c\u093e\u0909\u0902\u0938 \u092a\u094d\u0930\u0940-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 (\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0942\u0930\u094d\u0923 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0938\u0902\u092a\u0940\u0921\u093c\u0928 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0906\u092a\u0938 \u092e\u0947\u0902 \u091c\u0941\u0921\u093c \u091c\u093e\u0928\u093e) \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935 \u0915\u094b \u0924\u0947\u091c \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>IEC 62271-100 \u092c\u093e\u0909\u0902\u0938 \u0915\u094b \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u092e\u093e\u092a\u0928 \u0915\u0947 \u092c\u093e\u0926 \u22650.3 \u092e\u093f\u092e\u0940 \u0915\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0906\u0927\u0941\u0928\u093f\u0915 VCBs \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u0932\u093f\u0915 \u0921\u0948\u0936\u092a\u0949\u091f\u094d\u0938 \u0914\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u092b\u093c\u0930\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u092c\u093e\u0909\u0902\u0938 \u0915\u094b &lt;0.1 \u092e\u093f\u092e\u0940 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u092c\u093e\u0909\u0902\u0938 \u092e\u093e\u092a\u0928<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0909\u091a\u094d\u091a \u0938\u0902\u0915\u0932\u094d\u092a (\u226510 kHz \u0938\u0948\u0902\u092a\u0932\u093f\u0902\u0917) \u0915\u0947 \u0938\u093e\u0925 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0915\u0947 \u0938\u092e\u093e\u092a\u0928 \u0915\u094b \u0915\u0948\u092a\u094d\u091a\u0930 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092a\u0939\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0947\u0902 (\u0938\u094d\u0925\u093f\u0924\u093f \u092c\u0922\u093c\u0928\u093e \u092c\u0902\u0926 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948)<\/li>\n\n\n\n<li>\u0915\u093f\u0938\u0940 \u092d\u0940 \u092c\u093e\u0926 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u094b \u092e\u093e\u092a\u0947\u0902 (\u092c\u093e\u0909\u0902\u0938\/\u092a\u0941\u0928\u0903\u0916\u094b\u0932\u0947 \u091c\u093e\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924)<\/li>\n\n\n\n<li>\u092c\u093e\u0909\u0902\u0938 \u0926\u0942\u0930\u0940 \u0914\u0930 \u0905\u0935\u0927\u093f \u0915\u0940 \u0917\u0923\u0928\u093e \u0915\u0930\u0947\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0909\u091b\u093e\u0932 \u0938\u0940\u092e\u093e\u090f\u0901<\/strong>:<br>\u2022\u00a0<strong>\u0926\u0942\u0930\u0940<\/strong>: &lt;0.3 \u092e\u093f\u092e\u0940 (\u0906\u0908\u0908\u0938\u0940 \u0938\u0940\u092e\u093e), &lt;0.1 \u092e\u093f\u092e\u0940 (\u0926\u0940\u0930\u094d\u0918\u093e\u092f\u0941 \u0915\u0947 \u0932\u093f\u090f \u0935\u0930\u0940\u092f)<br>\u2022\u00a0<strong>\u0905\u0935\u0927\u093f<\/strong>: &lt;2 ms (\u0932\u0902\u092c\u0940 \u0905\u0935\u0927\u093f \u2192 \u0909\u091a\u094d\u091a \u092a\u0942\u0930\u094d\u0935-\u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e)<br>\u2022\u00a0<strong>\u0917\u093f\u0928\u0924\u0940<\/strong>: \u090f\u0915\u0932 \u0909\u091b\u093e\u0932 \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948, \u0915\u0908 \u0909\u091b\u093e\u0932 \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902<\/p>\n\n\n\n<p><strong>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0909\u091b\u093e\u0932 \u0915\u093e \u0915\u093e\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u0938\u0902\u0924 \u0915\u094b \u092c\u0902\u0926 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u092c\u0939\u0941\u0924 \u0915\u0920\u094b\u0930 (\u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0917\u0924\u093f\u091c \u090a\u0930\u094d\u091c\u093e)<\/li>\n\n\n\n<li>\u0921\u0948\u0936\u092a\u0949\u091f \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 (\u0917\u0932\u0924 \u0926\u094d\u0930\u0935 \u091a\u093f\u092a\u091a\u093f\u092a\u093e\u0939\u091f)<\/li>\n\n\n\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u0905\u0928\u093f\u092f\u092e\u093f\u0924 (\u092a\u093f\u091b\u0932\u0940 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0938\u0947 \u092c\u0928\u0947 \u0917\u0921\u094d\u0922\u0947 \u0905\u0938\u092e\u093e\u0928 \u0938\u094d\u092a\u0930\u094d\u0936 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902)<\/li>\n<\/ul>\n\n\n\n<p>60 VCBs \u0938\u0947 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u092b\u0940\u0932\u094d\u0921 \u0921\u0947\u091f\u093e \u0928\u0947 \u0926\u093f\u0916\u093e\u092f\u093e \u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u0938\u0947\u0935\u093e \u091c\u0940\u0935\u0928 \u0915\u0947 \u0938\u093e\u0925 \u0930\u0948\u0916\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092c\u0922\u093c\u0924\u093e \u0939\u0948: \u0928\u090f \u092f\u0942\u0928\u093f\u091f\u094d\u0938 \u092e\u0947\u0902 \u0914\u0938\u0924\u0928 0.05 \u092e\u093f\u092e\u0940, 10 \u0935\u0930\u094d\u0937 \u092a\u0941\u0930\u093e\u0928\u0947 \u092f\u0942\u0928\u093f\u091f\u094d\u0938 \u092e\u0947\u0902 \u0914\u0938\u0924\u0928 0.15 \u092e\u093f\u092e\u0940, 20 \u0935\u0930\u094d\u0937 \u092a\u0941\u0930\u093e\u0928\u0947 \u092f\u0942\u0928\u093f\u091f\u094d\u0938 \u092e\u0947\u0902 \u0914\u0938\u0924\u0928 0.35 \u092e\u093f\u092e\u0940 (IEC \u0938\u0940\u092e\u093e\u0913\u0902 \u0938\u0947 \u0905\u0927\u093f\u0915)\u0964 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0914\u0930 \u0921\u0948\u0936\u092a\u0949\u091f \u0938\u0930\u094d\u0935\u093f\u0938 \u0915\u0947 \u0938\u093e\u0925 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u092c\u093e\u0909\u0902\u0938 \u0915\u094b 0.1 \u092e\u093f\u092e\u0940 \u0938\u0947 \u0915\u092e \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04.webp\" alt=\"IEC 62271-100 \u0938\u0940\u092e\u093e \u0915\u0947 \u092d\u0940\u0924\u0930 0.2 \u092e\u093f\u092e\u0940 \u0906\u092f\u093e\u092e \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u092e\u093e\u092a\u0928 \u0915\u0947 \u0938\u093e\u0925 VCB \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u0940 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0926\u093f\u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u0917\u094d\u0930\u093e\u092b\" class=\"wp-image-2426\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u091a\u093f\u0924\u094d\u0930 4. \u0938\u0902\u092a\u0930\u094d\u0915 \u0909\u091b\u093e\u0932 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0941\u0906 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u093e \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930: 25 ms \u092a\u0930 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u091c\u093f\u0938\u0915\u0947 \u092c\u093e\u0926 0.2 mm \u0915\u093e \u0909\u091b\u093e\u0932 (1.5 ms \u0915\u0940 \u0905\u0935\u0927\u093f)\u2014IEC 62271-100 \u0938\u0940\u092e\u093e \u0915\u0947 \u092d\u0940\u0924\u0930<0.3 mm). Excessive bounce (>(0.3 \u092e\u093f\u092e\u0940) \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u092f\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u0915\u0940 \u0905\u0928\u093f\u092f\u092e\u093f\u0924\u0924\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0947 \u092a\u0941\u0928\u0930\u094d\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"timing-test-frequency-and-recordkeeping\">\u0938\u092e\u092f-\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0914\u0930 \u0905\u092d\u093f\u0932\u0947\u0916-\u0930\u0916\u0930\u0916\u093e\u0935<\/h2>\n\n\n\n<p>IEC 62271-100 \u0914\u0930 IEEE C37.09 \u0938\u0947\u0935\u093e \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u094d\u0930\u092e\u093f\u0915 \u0917\u093f\u0930\u093e\u0935\u091f \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0927\u093f\u0915 \u0938\u092e\u092f \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0940 \u0905\u0928\u0941\u0936\u0902\u0938\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0915\u0947 \u0926\u093e\u092f\u093f\u0924\u094d\u0935 \u0914\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0906\u092f\u0941 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0902\u0924\u0930\u093e\u0932<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0906\u092f\u094b\u0917\u0928<\/strong>\u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0942\u0930\u094d\u0923 \u0938\u092e\u092f-\u0915\u094d\u0930\u092e \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/li>\n\n\n\n<li><strong>\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (\u092a\u0939\u0932\u0947 5 \u0935\u0930\u094d\u0937)<\/strong>: \u0915\u0947\u0935\u0932 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u092e\u093e\u092a\u0928 (\u0924\u094d\u0935\u0930\u093f\u0924 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923)<\/li>\n\n\n\n<li><strong>\u0926\u094d\u0935\u093f\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (6-15 \u0935\u0930\u094d\u0937)<\/strong>: \u0916\u0941\u0932\u0928\u0947\/\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f + \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930<\/li>\n\n\n\n<li><strong>\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (&gt;15 \u0935\u0930\u094d\u0937 \u092f\u093e \u092d\u093e\u0930\u0940 \u0936\u0941\u0932\u094d\u0915)<\/strong>: \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u091a\u0932\u0928 \u0914\u0930 \u092c\u0939\u0941-\u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0939\u093f\u0924 \u092a\u0942\u0930\u094d\u0923 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0906\u0932\u094b\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0905\u092d\u093f\u0932\u0947\u0916-\u0930\u0916\u0930\u0916\u093e\u0935<\/strong>\u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0914\u0930 \u091f\u094d\u0930\u0947\u0902\u0921\u093f\u0902\u0917 \u0921\u0947\u091f\u093e \u0938\u0947 \u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0935\u0915\u094d\u0930 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964 \u090f\u0915 \u092c\u094d\u0930\u0947\u0915\u0930 \u091c\u093f\u0938\u0915\u093e \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f 32 ms (\u0928\u092f\u093e) \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 38 ms (\u0935\u0930\u094d\u0937 10) \u0914\u0930 44 ms (\u0935\u0930\u094d\u0937 15) \u0939\u094b \u0917\u092f\u093e \u0939\u0948, \u0935\u0939 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u0947\u092f \u0917\u093f\u0930\u093e\u0935\u091f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u201448 ms (\u0930\u0947\u091f\u0947\u0921 40 ms \u0915\u0947 120%) \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u093e \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0928\u093f\u0917\u0930\u093e\u0928\u0940<\/strong>\u0906\u0927\u0941\u0928\u093f\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 (SEL-487V, ABB REM615) \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0909\u0926\u094d\u0918\u093e\u091f\u0928\/\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u092e\u093e\u092a\u0924\u0947 \u0939\u0948\u0902 (\u0906\u0930\u094d\u0915\u0947\u0938\u094d\u091f \u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u0915\u0947 \u0906\u0930\u0902\u092d \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u0932\u0917\u093e\u0935 \u0915\u0947 \u0915\u094d\u0937\u0923 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u0947 \u0939\u0948\u0902)\u0964 \u092f\u0939 \u0938\u092e\u0930\u094d\u092a\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u092c\u093f\u0928\u093e \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0938\u092e\u092f \u092e\u0947\u0902 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0939\u092e\u0928\u0947 40 VCBs \u092a\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0932\u093e\u0917\u0942 \u0915\u0940; 6 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 (15%) \u092e\u0947\u0902 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0915\u094d\u0937\u0930\u0923 \u0915\u0947 \u0930\u0941\u091d\u093e\u0928 \u0926\u0947\u0916\u0947 \u0917\u090f, \u091c\u093f\u0928\u094d\u0939\u094b\u0902\u0928\u0947 \u0909\u0928\u094d\u0939\u0947\u0902 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0935\u093f\u092b\u0932 \u0939\u094b\u0928\u0947 \u0938\u0947 12\u201318 \u092e\u0939\u0940\u0928\u0947 \u092a\u0939\u0932\u0947 \u0939\u0940 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0947 \u0932\u093f\u090f \u091f\u094d\u0930\u093f\u0917\u0930 \u0915\u093f\u092f\u093e\u2014\u091c\u093f\u0938\u0938\u0947 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0935\u093f\u0930\u093e\u092e\u094b\u0902 \u0938\u0947 \u092c\u091a\u093e\u0935 \u0939\u0941\u0906\u0964.<\/p>\n\n\n\n<p>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0947 \u092a\u0930\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0947 \u0906\u0915\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f, \u0926\u0947\u0916\u0947\u0902&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vacuum-interrupter-contact-wear-replacement-guide\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u093e\u0935 \u0914\u0930 \u091c\u0940\u0935\u0928-\u0905\u0902\u0924 \u092e\u093e\u0928\u0926\u0902\u0921<\/a>.<\/p>\n\n\n<p>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0941\u0928\u0930\u093e\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0907\u0902\u091f\u0930\u092b\u093c\u0947\u0938 \u091c\u093e\u0901\u091a\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0907\u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/drawout-vcb-racking-safety-shutters-alignment-checks\/\">\u0921\u094d\u0930\u093e-\u0906\u0909\u091f VCB \u0930\u0948\u0915\u093f\u0902\u0917 \u0914\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/a>&nbsp;\u0906\u092a\u0915\u0940 \u0906\u0935\u0927\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u094b\u091c\u0928\u093e \u0915\u0947 \u0932\u093f\u090f\u0964.<\/p>\n\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937<\/h2>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u0939 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0914\u0930 IEC 62271-100 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0939\u0948\u2014\u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0941\u090f \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094d\u0937\u0924\u093f \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0926\u094b\u0937\u092a\u0942\u0930\u094d\u0923 \u0927\u093e\u0930\u093e \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 30-50 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0930\u0947\u091f\u0947\u0921 \u092e\u093e\u0928 +10% \u0915\u0947 \u092d\u0940\u0924\u0930 \u0930\u0939\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u0924\u093e\u0915\u093f \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u091a\u092f (&gt;2 kJ \u0938\u092e\u092f \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u093e \u0939\u0948) \u0915\u094b \u0930\u094b\u0915\u093e \u091c\u093e \u0938\u0915\u0947\u0964 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0915\u094b \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948: \u091a\u093f\u0915\u0928\u0940 \u0924\u094d\u0935\u0930\u0923 \u0909\u091a\u093f\u0924 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948, \u0921\u0948\u0936\u092a\u0949\u091f \u092e\u0947\u0902 \u0938\u094d\u092a\u0937\u094d\u091f \u092e\u0902\u0926\u0940 \u0906\u0918\u093e\u0924 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0930\u094b\u0915\u0924\u0940 \u0939\u0948, \u0914\u0930 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0938\u0902\u092a\u0930\u094d\u0915 \u0909\u091b\u093e\u0932 (IEC \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 &lt;0.3 \u092e\u093f\u092e\u0940, &lt;0.1 \u092e\u093f\u092e\u0940 \u0935\u093e\u0902\u091b\u0928\u0940\u092f) \u092a\u094d\u0930\u0940-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0918\u093f\u0938\u093e\u0935 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092b\u0940\u0932\u094d\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901 80\u2013110% \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u093e\u092a\u0924\u0940 \u0939\u0948\u0902, \u0930\u0948\u0916\u093f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u092f\u093e \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902, \u0914\u0930 \u0915\u094d\u0937\u0930\u0923 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092c\u0939\u0941-\u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0935\u093f\u091a\u0932\u0928\u094b\u0902 \u0915\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0928\u093f\u0926\u093e\u0928 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948: \u0927\u0940\u092e\u0940 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0926\u0930 \u0915\u092e\u091c\u094b\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092f\u093e \u092c\u0922\u093c\u0947 \u0939\u0941\u090f \u0918\u0930\u094d\u0937\u0923 (\u0938\u094d\u0928\u0947\u0939\u0928, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928) \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u0947\u0902 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0932\u0948\u091a \u0915\u0947 \u0918\u093f\u0938\u093e\u0935 \u092f\u093e \u0915\u0949\u0907\u0932 \u0915\u0947 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0940 \u0913\u0930 \u0938\u0902\u0915\u0947\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, \u0914\u0930 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0947 \u0921\u093f\u0938\u0948\u0932\u0947\u0930\u0947\u0936\u0928 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u093e \u0928\u0941\u0915\u0938\u093e\u0928 \u0924\u0930\u0932 \u0930\u093f\u0938\u093e\u0935 \u092f\u093e \u0938\u092e\u093e\u092f\u094b\u091c\u0928 \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092e\u0941\u0916\u094d\u092f \u0905\u0902\u0924\u0930\u094d\u0926\u0943\u0937\u094d\u091f\u093f: \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0947 \u092e\u0939\u0940\u0928\u094b\u0902 \u092f\u093e \u0935\u0930\u094d\u0937\u094b\u0902 \u092a\u0939\u0932\u0947 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0930\u0923 \u0915\u0940 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964 \u090f\u0915 \u092c\u094d\u0930\u0947\u0915\u0930 \u091c\u093f\u0938\u0915\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f 10 \u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 35 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0938\u0947 42 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0924\u0915 \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948, \u0935\u0939 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u0947\u092f \u0918\u093f\u0938\u093e\u0935 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u091c\u093f\u0938\u0938\u0947 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0947 \u092c\u091c\u093e\u092f \u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u0938\u0902\u092d\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 (\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u093e\u092a\u0928\u093e) \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u094b \u0906\u0935\u0927\u093f\u0915 \u091d\u0932\u0915\u093f\u092f\u094b\u0902 \u0938\u0947 \u0928\u093f\u0930\u0902\u0924\u0930 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u092e\u0947\u0902 \u092c\u0926\u0932 \u0926\u0947\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0905\u0926\u0943\u0936\u094d\u092f \u0915\u094d\u0937\u0930\u0923 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u091a\u0932\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0909\u091a\u093f\u0924 \u0938\u092e\u092f-\u0938\u092e\u092f \u092a\u0930 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0914\u0930 \u0930\u0941\u091d\u093e\u0928 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 VCB \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094b \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e\u0936\u0940\u0932 (\u0935\u093f\u092b\u0932 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928) \u0938\u0947 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093e\u0924\u094d\u092e\u0915 (\u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u0947 \u0928\u093f\u0915\u091f \u0939\u094b\u0928\u0947 \u092a\u0930 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923) \u092e\u0947\u0902 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u091c\u093f\u0938\u0938\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0930\u0941\u0915\u093e\u0935\u091f \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0941\u090f \u0938\u0947\u0935\u093e \u091c\u0940\u0935\u0928 \u0915\u094b \u0905\u0927\u093f\u0915\u0924\u092e \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vcb-timing-test--travel-curves\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928: \u0935\u0940\u0938\u0940\u092c\u0940 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u091f\u094d\u0930\u0948\u0935\u0932 \u0935\u0915\u094d\u0930<\/h2>\n\n\n\n<p><strong>Q1: IEC 62271-100 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 40 ms \u0930\u0947\u091f\u0947\u0921 VCB \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u0915\u094d\u092f\u093e \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>IEC 62271-100 \u0930\u0947\u091f\u0947\u0921 \u092e\u093e\u0928 \u0915\u0947 110% \u0924\u0915 \u0905\u0927\u093f\u0915\u0924\u092e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948\u0964 40 ms \u0930\u0947\u091f\u0947\u0921 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0932\u093f\u090f, \u092e\u093e\u092a\u093e \u0917\u092f\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u226444 ms \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948\u0964 44-48 ms (110-120%) \u0915\u0947 \u092e\u093e\u0928 \u091c\u093e\u0902\u091a \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u2014\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0928\u0947\u0939\u0928, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0938\u092e\u093e\u092f\u094b\u091c\u0928, \u092f\u093e \u0921\u0948\u0936\u092a\u0949\u091f \u0938\u0947\u0935\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 48 ms (&gt;120%) \u0938\u0947 \u0905\u0927\u093f\u0915 \u092e\u093e\u0928 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0915\u094d\u0937\u092f \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0915\u0947 \u0932\u093f\u090f \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u092f\u093e \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f = \u0935\u093f\u092e\u094b\u091a\u0928 \u0938\u092e\u092f (\u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u2192 \u0932\u0948\u091a \u0935\u093f\u092e\u094b\u091a\u0928, 5-15 ms) + \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0938\u092e\u092f (\u0932\u0948\u091a \u0935\u093f\u092e\u094b\u091a\u0928 \u2192 \u092a\u0942\u0930\u094d\u0923 \u0938\u094d\u091f\u094d\u0930\u094b\u0915, 15-30 ms) + \u0906\u0930\u094d\u0915 \u0905\u0935\u0927\u093f (5-10 ms)\u0964 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u0924\u093e \u0939\u0948 \u0915\u093f 120% \u0930\u0947\u091f\u0947\u0921 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u0932\u0947\u0928\u0947 \u0935\u093e\u0932\u0947 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092e\u0947\u0902 \u0926\u094b\u0937 \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e (&gt;2.5 kJ \u092c\u0928\u093e\u092e 25 kA \u092a\u0930 &lt;2.0 kJ \u0915\u0940 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0938\u0940\u092e\u093e) \u0915\u0947 \u0915\u093e\u0930\u0923 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0940 \u0926\u0930 3-5 \u0917\u0941\u0928\u093e \u0905\u0927\u093f\u0915 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 2: \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0947 \u0915\u094d\u0937\u092f \u0915\u094b \u0915\u0948\u0938\u0947 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u090f\u0915 \u0938\u094d\u0935\u0938\u094d\u0925 \u091f\u094d\u0930\u0948\u0935\u0932 \u0935\u0915\u094d\u0930 \u0924\u0940\u0928 \u091a\u0930\u0923 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948: (1) \u0924\u094d\u0935\u0930\u0923 (\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0940 \u0917\u0924\u093f \u092c\u0922\u093c\u0924\u0940 \u0939\u0948, 0-60% \u0938\u094d\u091f\u094d\u0930\u094b\u0915), (2) \u0938\u094d\u0925\u093f\u0930 \u0935\u0947\u0917 (\u091a\u0930\u092e \u0917\u0924\u093f \u092c\u0928\u0940 \u0930\u0939\u0924\u0940 \u0939\u0948, 60-80% \u0938\u094d\u091f\u094d\u0930\u094b\u0915), (3) \u0905\u0935\u092e\u0902\u0926\u0928 (\u0921\u0948\u0936\u092a\u0949\u091f \u090a\u0930\u094d\u091c\u093e \u0905\u0935\u0936\u094b\u0937\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948, 80-100% \u0938\u094d\u091f\u094d\u0930\u094b\u0915)\u0964 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u091a\u0930\u0923 3 \u0915\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u092a\u094d\u0930\u0915\u091f \u0939\u094b\u0924\u0940 \u0939\u0948\u2014\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0905\u0935\u0930\u094b\u0927 \u0924\u0915 \u0938\u094d\u0925\u093f\u0930 \u0935\u0947\u0917 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0905\u091a\u093e\u0928\u0915 \u0930\u0941\u0915\u093e\u0935\u091f \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0907\u0938\u0938\u0947 10-20 \u0917\u0941\u0928\u093e \u0905\u0927\u093f\u0915 \u092a\u094d\u0930\u092d\u093e\u0935 \u092c\u0932 (\u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0947 \u0938\u093e\u0925 50-100 N \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 500-1000 N) \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u092a\u093f\u0935\u091f \u092a\u093f\u0928, \u0932\u093f\u0902\u0915 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0902\u0930\u0947\u0916\u0923 \u092a\u0930 \u0918\u093f\u0938\u093e\u0935 \u0915\u094b \u0924\u0947\u091c \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092e\u0942\u0932 \u0915\u093e\u0930\u0923: \u0921\u0948\u0936\u092a\u0949\u091f \u0924\u0930\u0932 \u0915\u093e \u0930\u093f\u0938\u093e\u0935 (\u0938\u0940\u0932 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e), \u0917\u0932\u0924 \u0924\u0930\u0932 \u091a\u093f\u092a\u091a\u093f\u092a\u093e\u0939\u091f (\u0917\u0932\u0924 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0924\u0930\u0932), \u092f\u093e \u0938\u092e\u093e\u092f\u094b\u091c\u0928 \u0924\u094d\u0930\u0941\u091f\u093f (\u092a\u093f\u0938\u094d\u091f\u0928 \u0915\u093e \u0928 \u091c\u0941\u0921\u093c\u0928\u093e)\u0964 \u0907\u0938\u0947 \u0920\u0940\u0915 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u093f\u0924 \u0938\u0940\u0932 \u0914\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e-\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0924\u0930\u0932 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0938\u093f\u0932\u093f\u0915\u0949\u0928 \u0924\u0947\u0932, 100-500 cSt \u091a\u093f\u092a\u091a\u093f\u092a\u093e\u0939\u091f) \u0915\u0947 \u0938\u093e\u0925 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u093e \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0930\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 10-20 \u0938\u093e\u0932 \u092a\u0941\u0930\u093e\u0928\u0947 120 VCBs \u0915\u0947 \u0939\u092e\u093e\u0930\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u092a\u093e\u092f\u093e \u0917\u092f\u093e \u0915\u093f 25% \u092e\u0947\u0902 \u0921\u0948\u0936\u092a\u0949\u091f \u0915\u0940 \u0917\u0924\u093f \u092e\u0947\u0902 \u0915\u094b\u0908 \u0938\u094d\u092a\u0937\u094d\u091f \u0915\u092e\u0940 \u0928\u0939\u0940\u0902 \u0925\u0940\u0964.<\/p>\n\n\n\n<p><strong>Q3: 80% \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 VCB \u0915\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f 10-15% \u0915\u094d\u092f\u094b\u0902 \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0915\u093e \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092c\u0932 F \u221d (I_coil)\u00b2 \u221d (V \/ R)\u00b2\u0964 80% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930, \u092c\u0932 \u0930\u0947\u091f\u0947\u0921 \u0915\u0947 (0.8)\u00b2 = 64% \u0924\u0915 \u0917\u093f\u0930 \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0915\u092e \u092c\u0932 \u0915\u093e \u0905\u0930\u094d\u0925 \u0939\u0948 \u0905\u0927\u093f\u0915 \u0930\u093f\u0932\u0940\u091c\u093c \u0938\u092e\u092f (\u0932\u0948\u091a \u0915\u092e \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0916\u093f\u0902\u091a\u093e\u0935 \u0915\u094b \u0905\u0927\u093f\u0915 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u092a\u093e\u0930 \u0915\u0930\u0924\u093e \u0939\u0948) \u0914\u0930 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0915\u092e \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0924\u094d\u0935\u0930\u0923\u0964 IEC 62271-100 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0936\u0915\u094d\u0924\u093f \u092e\u0947\u0902 \u092d\u093f\u0928\u094d\u0928\u0924\u093e\u0913\u0902 \u0915\u094b \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f 70-110% \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u0938\u092b\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964 \u092f\u0926\u093f 110% \u0914\u0930 80% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u092c\u0940\u091a \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f &gt;20% \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0938\u0902\u0926\u0947\u0939 \u0915\u0930\u0947\u0902: (1) \u0915\u0949\u0907\u0932 \u0915\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 (\u0926\u0942\u0937\u0923, \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e\u0940), (2) \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091camming (\u0918\u0930\u094d\u0937\u0923 \u0915\u092e \u0939\u0941\u090f \u092c\u0932 \u0915\u094b \u0938\u0902\u0924\u0941\u0932\u093f\u0924 \u0915\u0930 \u0930\u0939\u093e \u0939\u0948), (3) \u0932\u0948\u091a \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0939\u0941\u0924 \u092e\u091c\u092c\u0942\u0924 (\u091b\u094b\u0921\u093c\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0927\u093f\u0915 \u092c\u0932 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e)\u0964 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0915\u093e \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0940\u092e\u093e \u092e\u0947\u0902 10-15% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 70%, 80%, 100%, 110% \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u0916\u0941\u0932\u0928\u0947 \u0915\u0947 \u0938\u092e\u092f \u0915\u094b \u092e\u093e\u092a\u0915\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902; 70% \u092a\u0930 \u0915\u093e\u092e \u0928 \u0915\u0930\u0928\u093e \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 80-110% \u092a\u0930 \u0905\u0938\u0902\u0917\u0924 \u0938\u092e\u092f \u092f\u0939 \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948 \u0915\u093f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092f\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0938\u0902\u092c\u0902\u0927\u0940 \u0917\u093f\u0930\u093e\u0935\u091f \u0906\u0908 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q4: \u092c\u0902\u0926 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u0915\u094d\u092f\u093e \u0915\u093e\u0930\u0923 \u0939\u094b\u0924\u093e \u0939\u0948 \u0914\u0930 \u092f\u0939 \u0915\u094d\u092f\u094b\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u0938\u0902\u092a\u0930\u094d\u0915 \u0909\u091b\u093e\u0932 \u0924\u092c \u0939\u094b\u0924\u093e \u0939\u0948 \u091c\u092c \u091a\u0932 \u0930\u0939\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0940 \u0917\u0924\u093f\u091c \u090a\u0930\u094d\u091c\u093e \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\/\u0921\u0948\u0936\u092a\u0949\u091f \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0915\u094d\u0937\u092e\u0924\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u092a\u0930, \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0923 \u092d\u0930 \u0915\u0947 \u0932\u093f\u090f \u0905\u0932\u0917 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 (0.1-0.5 \u092e\u093f\u092e\u0940, 1-3 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0905\u0935\u0927\u093f) \u092b\u093f\u0930 \u0938\u0947 \u0938\u094d\u0925\u093f\u0930 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947\u0964 \u0909\u091b\u093e\u0932 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u0938\u0902\u092a\u0930\u094d\u0915 \u092b\u093f\u0930 \u0938\u0947 \u0916\u0941\u0932 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 \u091c\u092c\u0915\u093f \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0927\u093e\u0930\u093e \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b \u0930\u0939\u0940 \u0939\u094b\u0924\u0940 \u0939\u0948 \u2192 \u0907\u0938\u0938\u0947 \u092a\u0942\u0930\u094d\u0935-\u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948 \u091c\u094b \u092a\u0942\u0930\u094d\u0923 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0938\u0902\u092a\u0940\u0921\u093c\u0928 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939\u094b\u0902 \u0915\u094b \u091c\u094b\u0921\u093c \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u0938\u0902\u092a\u0930\u094d\u0915 \u0926\u092c\u093e\u0935 \u0915\u094b \u0915\u092e \u0915\u0930\u0924\u093e \u0939\u0948, \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u092c\u0922\u093c\u093e\u0924\u093e \u0939\u0948, \u0914\u0930 \u0915\u094d\u0937\u0930\u0923 \u0915\u094b \u0924\u0947\u091c \u0915\u0930\u0924\u093e \u0939\u0948\u0964 IEC 62271-100 \u092c\u093e\u0909\u0902\u0938 \u0915\u094b 10,000 \u0938\u0902\u091a\u093e\u0932\u0928) \u0915\u0947 \u0932\u093f\u090f &lt;0.1 \u092e\u093f\u092e\u0940 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0905\u092d\u094d\u092f\u093e\u0938 \u0939\u0948\u0964 \u0915\u093e\u0930\u0923: \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0932 (\u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u0917\u0924\u093f\u091c \u090a\u0930\u094d\u091c\u093e), \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0921\u0948\u0936\u092a\u0949\u091f \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 (\u0917\u0932\u0924 \u0926\u094d\u0930\u0935 \u0938\u093e\u0928\u094d\u0926\u094d\u0930\u0924\u093e), \u092f\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939 \u0915\u0940 \u0905\u0928\u093f\u092f\u092e\u093f\u0924\u0924\u093e (\u092a\u093f\u091f\u093f\u0902\u0917 \u0905\u0938\u092e\u093e\u0928 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u0940 \u0939\u0948)\u0964 \u0909\u091a\u094d\u091a-\u0930\u093f\u091c\u093c\u0949\u0932\u094d\u092f\u0942\u0936\u0928 \u091f\u094d\u0930\u0948\u0935\u0932 \u0915\u0930\u094d\u0935 (\u226510 kHz \u0938\u0948\u0902\u092a\u0932\u093f\u0902\u0917) \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u092e\u093e\u092a\u0947\u0902; \u092a\u0939\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u0915\u0947 \u092c\u093e\u0926 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0935\u0943\u0926\u094d\u0927\u093f \u0926\u0947\u0916\u0947\u0902\u0964 \u0938\u092e\u093e\u0927\u093e\u0928: \u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0940\u0932\u094b\u0921 \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902, \u0921\u0948\u0936\u092a\u0949\u091f \u0926\u094d\u0930\u0935 \u092c\u0926\u0932\u0947\u0902, \u092f\u093e \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0940 \u0938\u0924\u0939 \u092b\u093f\u0930 \u0938\u0947 \u0924\u0948\u092f\u093e\u0930 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q5: VCB \u0915\u0940 \u0938\u0947\u0935\u093e \u0905\u0935\u0927\u093f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u091a\u093e\u0939\u093f\u090f?<\/strong><\/p>\n\n\n\n<p>\u0915\u0930\u094d\u0924\u0935\u094d\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902: (1)&nbsp;<strong>\u0906\u092f\u094b\u0917\u0928<\/strong>&nbsp;\u2013 \u0906\u0927\u093e\u0930 \u0930\u0947\u0916\u093e \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090a\u0930\u094d\u091c\u093e\u0915\u0930\u0923 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0942\u0930\u094d\u0923 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923; (2)&nbsp;<strong>\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (0-5 \u0935\u0930\u094d\u0937)<\/strong>&nbsp;\u2013 \u0915\u0947\u0935\u0932 \u0924\u094d\u0935\u0930\u093f\u0924 \u091c\u093e\u0901\u091a \u0938\u092e\u092f; (3)&nbsp;<strong>\u0926\u094d\u0935\u093f\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (6-15 \u0935\u0930\u094d\u0937)<\/strong>&nbsp;\u2013 \u0916\u0941\u0932\u0928\u0947\/\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930; (4)&nbsp;<strong>\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (&gt;15 \u0935\u0930\u094d\u0937 \u092f\u093e \u092d\u093e\u0930\u0940 \u0936\u0941\u0932\u094d\u0915 &gt;1000 \u0938\u0902\u091a\u093e\u0932\u0928\/\u0935\u0930\u094d\u0937)<\/strong>&nbsp;\u2013 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u093f\u091a\u0932\u0928 \u0914\u0930 10-\u0911\u092a\u0930\u0947\u0936\u0928 \u091f\u093f\u0915\u093e\u090a\u092a\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0939\u093f\u0924 \u092a\u0942\u0930\u094d\u0923 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923\u0964 IEC 62271-100 \u0914\u0930 IEEE C37.09 2,000-5,000 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092c\u093e\u0926 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0905\u0928\u0941\u0936\u0902\u0938\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 (\u091c\u094b 10-15 \u0935\u0930\u094d\u0937 \u0915\u0940 \u0938\u0947\u0935\u093e \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0939\u0948)\u0964 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u093e\u092a (SEL-487V, ABB REM615) \u0935\u093e\u0932\u0947 \u0906\u0927\u0941\u0928\u093f\u0915 \u0930\u093f\u0932\u0947 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0938\u092e\u092f \u092e\u0947\u0902 \u0930\u0941\u091d\u093e\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u2014\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0938\u094d\u0928\u0948\u092a\u0936\u0949\u091f \u0915\u0947 \u092c\u091c\u093e\u092f \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u093e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u092e\u093e\u0930\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0928\u0947 \u0926\u093f\u0916\u093e\u092f\u093e \u0915\u093f \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0928\u0947 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 12-18 \u092e\u0939\u0940\u0928\u0947 \u092a\u0939\u0932\u0947 \u0917\u093f\u0930\u093e\u0935\u091f \u0915\u0947 \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u092f\u093e, \u091c\u093f\u0938\u0938\u0947 \u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0935\u093f\u0930\u093e\u092e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0915\u094d\u0930\u093f\u092f \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u0938\u0902\u092d\u0935 \u0939\u0941\u0906, \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0947 \u092c\u091c\u093e\u092f\u0964.<\/p>\n\n\n\n<p><strong>Q6: \u0915\u094d\u092f\u093e VCB \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092f\u0939 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902 \u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u092c \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948?<\/strong><\/p>\n\n\n\n<p>\u0905\u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0930\u0942\u092a \u0938\u0947 \u0939\u093e\u0901\u2014\u0916\u0941\u0932\u0928\u0947 \u0915\u0947 \u0938\u092e\u092f \u092e\u0947\u0902 \u0935\u0943\u0926\u094d\u0927\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u093e\u0935 \u0938\u0947 \u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0926\u094b\u0928\u094b\u0902 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u094d\u0937\u0930\u0923 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e \u0939\u0948\u0902\u0964 \u091c\u0948\u0938\u0947-\u091c\u0948\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u0924\u0947 \u0939\u0948\u0902, \u0938\u094d\u091f\u094d\u0930\u094b\u0915 \u0926\u0942\u0930\u0940 \u092c\u0926\u0932 \u091c\u093e\u0924\u0940 \u0939\u0948 (\u092a\u0942\u0930\u094d\u0923 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094b \u0905\u0927\u093f\u0915 \u0926\u0942\u0930\u0940 \u0924\u092f \u0915\u0930\u0928\u0940 \u092a\u0921\u093c\u0924\u0940 \u0939\u0948), \u0914\u0930 \u0924\u093e\u092a\u0940\u092f \u0924\u0928\u093e\u0935 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0932 \u0915\u092e\u091c\u094b\u0930 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u0947\u0902 10\u201320 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u0915\u0940 \u0935\u0943\u0926\u094d\u0927\u093f \u092f\u0939 \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948 \u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f \u092f\u0926\u093f \u0935\u0947 \u092e\u0942\u0932 \u092e\u094b\u091f\u093e\u0908 \u0915\u093e 30% \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u094d\u0937\u0930\u0923\u093f\u0924 \u0939\u094b\u0902 \u092f\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 500 \u00b5\u03a9 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0964 \u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928 (\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930), \u092a\u093f\u091f\u093f\u0902\u0917\/\u0915\u094d\u0937\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923, \u092f\u093e \u090f\u0915\u094d\u0938-\u0930\u0947 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 (\u0917\u0948\u0930-\u0906\u0915\u094d\u0930\u093e\u092e\u0915) \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948: \u090f\u0915 \u092c\u094d\u0930\u0947\u0915\u0930 \u091c\u093f\u0938\u0915\u093e \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u0932\u0917\u093e\u0924\u093e\u0930 3 \u0935\u0930\u094d\u0937\u094b\u0902 \u0924\u0915 1-2 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921\/\u0935\u0930\u094d\u0937 \u0915\u0940 \u0926\u0930 \u0938\u0947 \u092c\u0922\u093c\u093e \u0939\u0948, \u0909\u0938\u0947 2-3 \u0935\u0930\u094d\u0937\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0928\u0947 \u0915\u0940 \u0938\u0902\u092d\u093e\u0935\u0928\u093e \u0939\u0948\u0964 \u0938\u0902\u092f\u0941\u0915\u094d\u0924 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f (\u091f\u093e\u0907\u092e\u093f\u0902\u0917 + \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 + \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e) 85-90% \u0938\u091f\u0940\u0915\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u0915\u0940 \u091c\u0930\u0942\u0930\u0924\u094b\u0902 \u0915\u0940 \u092d\u0935\u093f\u0937\u094d\u092f\u0935\u093e\u0923\u0940 \u0915\u0930\u0924\u0940 \u0939\u0948, \u091c\u092c\u0915\u093f \u0915\u0947\u0935\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e \u0938\u0947 \u092f\u0939 \u0938\u091f\u0940\u0915\u0924\u093e 60-70% \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q7: \u092f\u0926\u093f \u092e\u093e\u092a\u093e \u0917\u092f\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f \u0930\u0947\u091f\u0947\u0921 \u0938\u092e\u092f \u0938\u0947 25% \u0927\u0940\u092e\u093e \u0939\u0948, \u0924\u094b \u092e\u0941\u091d\u0947 \u0915\u094c\u0928 \u0938\u0947 \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0915\u0926\u092e \u0909\u0920\u093e\u0928\u0947 \u091a\u093e\u0939\u093f\u090f?<\/strong><\/p>\n\n\n\n<p>\u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0928\u093f\u0926\u093e\u0928 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902: (1)&nbsp;<strong>\u092e\u093e\u092a \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong>&nbsp;\u2013 \u092f\u093e\u0924\u094d\u0930\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902, \u091c\u093e\u0902\u091a\u0947\u0902 \u0915\u093f \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930 \u0921\u0947\u091f\u093e \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0924\u0940 \u0939\u0948 (\u00b15 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921); (2)&nbsp;<strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>&nbsp;\u2013 80%, 100%, 110% \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u092e\u093e\u092a\u0947\u0902; \u092f\u0926\u093f \u0924\u0940\u0928\u094b\u0902 \u0938\u092e\u093e\u0928\u0941\u092a\u093e\u0924\u0940 \u0930\u0942\u092a \u0938\u0947 \u0927\u0940\u092e\u0940 \u0939\u0948\u0902, \u0924\u094b \u0938\u092e\u0938\u094d\u092f\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0939\u0948 (\u0915\u092e\u091c\u094b\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u0918\u0930\u094d\u0937\u0923); \u092f\u0926\u093f \u0915\u0947\u0935\u0932 \u0928\u093f\u092e\u094d\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0927\u0940\u092e\u0940 \u0939\u0948, \u0924\u094b \u0915\u0949\u0907\u0932\/\u0932\u0948\u091a \u0915\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u093e \u0938\u0902\u0926\u0947\u0939 \u0915\u0930\u0947\u0902; (3)&nbsp;<strong>\u092e\u0948\u0928\u0941\u0905\u0932 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>&nbsp;\u2013 \u0939\u093e\u0925 \u0938\u0947 \u0938\u093e\u0907\u0915\u093f\u0932 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094b \u0918\u0941\u092e\u093e\u090f\u0901, \u0905\u091f\u0915\u0928 \u092f\u093e \u0930\u0941\u0915\u093e\u0935\u091f \u0915\u0947 \u0932\u093f\u090f \u092e\u0939\u0938\u0942\u0938 \u0915\u0930\u0947\u0902; (4)&nbsp;<strong>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>&nbsp;\u2013 \u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u0915\u0935\u0930 \u0939\u091f\u093e\u090f\u0901, \u091f\u0942\u091f\u0947 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u0921\u0948\u0936\u092a\u0949\u091f \u0932\u0940\u0915, \u0918\u093f\u0938\u0947 \u0939\u0941\u090f \u092a\u093f\u0935\u091f \u092a\u093f\u0928 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902; (5)&nbsp;<strong>\u0938\u094d\u0928\u0947\u0939\u0928<\/strong>&nbsp;\u2013 \u0938\u092d\u0940 \u092a\u093f\u0935\u094b\u091f\u094d\u0938 \u0915\u094b \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0932\u0941\u092c\u094d\u0930\u093f\u0915\u0947\u0902\u091f (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 MoS\u2082 \u0917\u094d\u0930\u0940\u0938) \u0938\u0947 \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902 \u0914\u0930 \u092b\u093f\u0930 \u0938\u0947 \u091a\u093f\u0915\u0928\u093e\u0908 \u0932\u0917\u093e\u090f\u0901; (6)&nbsp;<strong>\u0935\u0938\u0902\u0924 \u0924\u0928\u093e\u0935<\/strong>&nbsp;\u2013 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0932 \u0915\u094b \u0917\u0947\u091c \u0938\u0947 \u092e\u093e\u092a\u0947\u0902 (\u0921\u0947\u091f\u093e\u0936\u0940\u091f \u092e\u093e\u0928 \u0915\u093e \u00b110% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f)\u0964 \u092f\u0926\u093f \u0938\u094d\u0928\u0947\u0939\u0928 \u0938\u0947 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 110% \u0930\u0947\u091f\u0947\u0921 \u0938\u0947 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948, \u0924\u094b \u092c\u0922\u093c\u0940 \u0939\u0941\u0908 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0947 \u0938\u093e\u0925 \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0932\u094c\u091f\u093e\u090f\u0902\u0964 \u092f\u0926\u093f \u0938\u0947\u0935\u093e \u0915\u0947 \u092c\u093e\u0926 &gt;110% \u0939\u0948, \u0924\u094b \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938\/\u0921\u0948\u0936\u092a\u0949\u091f \u092c\u0926\u0932\u0947\u0902\u0964 \u092f\u0926\u093f &gt;125% \u092f\u093e \u0915\u0908 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u0939\u0948\u0902, \u0924\u094b \u092a\u0942\u0930\u094d\u0923 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 \u092f\u093e \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u090f\u0902\u0964.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum circuit breaker (VCB) timing tests measure the mechanical response during opening and closing operations\u2014how fast contacts move, whether motion is smooth, and if performance matches manufacturer specifications. These tests verify that the breaker can interrupt fault current before damage occurs, that mechanical wear hasn\u2019t degraded performance, and that protection coordination assumptions remain valid. A [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2429,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2425"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2425\/revisions"}],"predecessor-version":[{"id":3569,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2425\/revisions\/3569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2429"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2425"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}