{"id":2511,"date":"2026-01-09T08:17:07","date_gmt":"2026-01-09T08:17:07","guid":{"rendered":"https:\/\/xbrele.com\/?p=2511"},"modified":"2026-04-07T14:53:36","modified_gmt":"2026-04-07T14:53:36","slug":"vacuum-contactor-maintenance-checklist","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/vacuum-contactor-maintenance-checklist\/","title":{"rendered":"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f: \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f, \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923"},"content":{"rendered":"<p>\u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0905\u092a\u0928\u0940 \u0938\u0947\u0935\u093e \u0905\u0935\u0927\u093f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 10,000\u2013100,000 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091a\u0915\u094d\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938, \u091c\u094b \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0915\u092d\u0940-\u0915\u092d\u0940 \u0935\u093f\u0930\u093e\u092e\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0915\u0947 \u0935\u093f\u092a\u0930\u0940\u0924 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0932\u094b\u0921 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u2014\u0905\u0915\u094d\u0938\u0930 \u092e\u094b\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0914\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f-\u0938\u094d\u091f\u0949\u092a \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0926\u093f\u0928 \u0915\u0908 \u092c\u093e\u0930\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u0926\u094b\u0939\u0930\u093e\u0935\u092a\u0942\u0930\u094d\u0923 \u0915\u093e\u0930\u094d\u092f \u090f\u0915 \u0910\u0938\u093e \u091a\u0915\u094d\u0930 \u0939\u0948 \u091c\u093f\u0938\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u091f\u0940\u092e\u0947\u0902 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0939\u091a\u093e\u0928\u0928\u0940 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0915\u094d\u0937\u092f, \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0925\u0915\u093e\u0928, \u0914\u0930 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u093e \u0915\u094d\u0937\u0930\u0923 \u0905\u092a\u0930\u093f\u0939\u093e\u0930\u094d\u092f \u0939\u0948\u0902\u2014\u0932\u0947\u0915\u093f\u0928 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093f\u0924\u0964 \u0938\u0902\u0930\u091a\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094d\u0937\u092f \u0915\u094b \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0905\u0935\u0938\u094d\u0925\u093e \u092e\u0947\u0902 \u0939\u0940 \u092a\u0915\u0921\u093c \u0932\u0947\u0924\u093e \u0939\u0948, \u091c\u092c \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0940 \u0932\u093e\u0917\u0924 \u0939\u091c\u093e\u0930\u094b\u0902 \u0915\u0940 \u092c\u091c\u093e\u092f \u0938\u0948\u0915\u0921\u093c\u094b\u0902 \u092e\u0947\u0902 \u0939\u094b\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0926\u093f\u0928\u094b\u0902 \u0915\u0940 \u092c\u091c\u093e\u092f \u092e\u093f\u0928\u091f\u094b\u0902 \u092e\u0947\u0902 \u092e\u093e\u092a\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u0928\u093e\u091f\u0915\u0940\u092f \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0935\u092f\u0902 \u0915\u094b \u092a\u094d\u0930\u0915\u091f \u0928\u0939\u0940\u0902 \u0915\u0930\u0924\u0940\u0902\u0964 \u0935\u0947 \u092e\u093e\u092a\u0928\u0940\u092f \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0909\u092d\u0930\u0924\u0940 \u0939\u0948\u0902: \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0906\u0927\u093e\u0930 \u0930\u0947\u0916\u093e \u0938\u0947 20% \u090a\u092a\u0930 \u092c\u0922\u093c\u0928\u093e, \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 5 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092c\u093e\u0939\u0930 \u092d\u091f\u0915\u0928\u093e, \u0932\u093f\u0902\u0915ages \u092e\u0947\u0902 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0916\u0947\u0932 \u0915\u093e \u092a\u094d\u0930\u0915\u091f \u0939\u094b\u0928\u093e\u0964 \u091c\u092c \u0907\u0928 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u091f\u094d\u0930\u0948\u0915 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u092f\u0947 \u0939\u092b\u094d\u0924\u094b\u0902 \u092f\u093e \u092e\u0939\u0940\u0928\u094b\u0902 \u092a\u0939\u0932\u0947 \u0939\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0940 \u092d\u0935\u093f\u0937\u094d\u092f\u0935\u093e\u0923\u0940 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0909\u0928 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902, \u092e\u093e\u092a\u094b\u0902 \u0914\u0930 \u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092e\u093e\u0928\u0926\u0902\u0921\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948 \u091c\u093f\u0928\u0915\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u093e \u0915\u0941\u0936\u0932\u0924\u093e\u092a\u0942\u0930\u094d\u0935\u0915 \u0906\u0915\u0932\u0928 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u091a\u093e\u0939\u0947 \u0906\u092a \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u092e\u094b\u091f\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u093e \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0915\u0930 \u0930\u0939\u0947 \u0939\u094b\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/\">\u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938<\/a>&nbsp;\u092f\u093e \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915\u094b\u0902 \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f, \u092f\u0947 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901 \u0938\u092d\u0940 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0914\u0930 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u092a\u0930 \u0932\u093e\u0917\u0942 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0916\u0930\u0916\u093e\u0935: \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u0914\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/x-4uOSbSMeo?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-maintenance-matters-more-for-contactors-than-breakers\">\u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u0949\u0928\u094d\u091f\u094d\u0930\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094d\u092f\u094b\u0902 \u0905\u0927\u093f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948<\/h2>\n\n\n\n<p>\u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u0935\u093f\u0930\u093e\u092e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u2014\u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e, \u0932\u0947\u0915\u093f\u0928 \u0926\u0941\u0930\u094d\u0932\u092d \u0938\u0902\u091a\u093e\u0932\u0928 (\u0936\u093e\u092f\u0926 \u0905\u092a\u0928\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092e\u0947\u0902 5\u201320 \u092c\u093e\u0930)\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u2014\u092e\u0927\u094d\u092f\u092e \u0927\u093e\u0930\u093e, \u0932\u0947\u0915\u093f\u0928 \u092a\u094d\u0930\u0924\u093f \u0935\u0930\u094d\u0937 \u0939\u091c\u093e\u0930\u094b\u0902 \u0938\u0902\u091a\u093e\u0932\u0928\u0964.<\/p>\n\n\n\n<p><strong>\u0936\u0941\u0932\u094d\u0915 \u0924\u0941\u0932\u0928\u093e:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th><th>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/th><th>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930<\/th><\/tr><\/thead><tbody><tr><td><strong>\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u091a\u093e\u0932\u0928\/\u0935\u0930\u094d\u0937<\/strong><\/td><td>5\u201320 (\u0924\u094d\u0930\u0941\u091f\u093f \u0928\u093f\u0935\u093e\u0930\u0923)<\/td><td>5,000\u201350,000 (\u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917)<\/td><\/tr><tr><td><strong>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u092c\u093e\u0927\u093f\u0924<\/strong><\/td><td>10\u201340\u00d7 \u0930\u0947\u091f\u0947\u0921 (\u0924\u094d\u0930\u0941\u091f\u093f)<\/td><td>1\u20138\u00d7 \u0930\u0947\u091f\u0947\u0921 (\u0907\u0928\u0930\u0936\/\u0932\u094b\u0921)<\/td><\/tr><tr><td><strong>\u092a\u094d\u0930\u0924\u093f \u0938\u0902\u091a\u093e\u0932\u0928 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e<\/strong><\/td><td>\u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915<\/td><td>\u092e\u0927\u094d\u092f\u092e<\/td><\/tr><tr><td><strong>\u0938\u0902\u091a\u092f\u0940 \u091a\u093e\u092a \u090a\u0930\u094d\u091c\u093e<\/strong><\/td><td>\u0928\u093f\u092e\u094d\u0928 (\u0915\u0941\u091b \u0939\u0940 \u0938\u0902\u091a\u093e\u0932\u0928)<\/td><td>\u0909\u091a\u094d\u091a (\u0915\u0908 \u0938\u0902\u091a\u093e\u0932\u0928)<\/td><\/tr><tr><td><strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932<\/strong><\/td><td>\u0968,\u0966\u0966\u0966\u2013\u096b,\u0966\u0966\u0966 \u0911\u092a\u094d\u0938<\/td><td>\u096b,\u0966\u0966\u0966\u2013\u0968\u0966,\u0966\u0966\u0966 \u0911\u092a\u094d\u0938<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u092f\u0939 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u091a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948, \u091c\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0918\u093f\u0938\u0924\u0940 \u0939\u0948, \u0924\u0902\u0924\u094d\u0930\u094b\u0902 \u092a\u0930 \u0924\u0928\u093e\u0935 \u0921\u093e\u0932\u0924\u0940 \u0939\u0948, \u0914\u0930 \u0905\u0902\u0924\u0924\u0903 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u094b \u0915\u092e\u091c\u094b\u0930 \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u0930\u0916\u0930\u0916\u093e\u0935 \u0907\u0928 \u0915\u094d\u0930\u092e\u093f\u0915 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0905\u092a\u094d\u0930\u0924\u094d\u092f\u093e\u0936\u093f\u0924 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0928\u0947 \u0938\u0947 \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-intervals-when-to-inspect\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932: \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u092c \u0915\u0930\u0947\u0902<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart.webp\" alt=\"\u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u0928\u093f\u0930\u094d\u0923\u092f \u092b\u094d\u0932\u094b\u091a\u093e\u0930\u094d\u091f \u091c\u094b \u0909\u091a\u094d\u091a-\u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u091a\u093e\u0932\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u0914\u0930 \u0928\u093f\u092e\u094d\u0928-\u0921\u094d\u092f\u0942\u091f\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0902\u0915\u0947\u0924\u0915\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964\" class=\"wp-image-2515\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0906\u0915\u0943\u0924\u093f 3**: \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u091a\u092f\u0928 \u0938\u0902\u091a\u093e\u0932\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 (\u0909\u091a\u094d\u091a-\u0915\u0930\u094d\u0924\u0935\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u0939\u0930 5,000\/10,000\/20,000 \u0938\u0902\u091a\u093e\u0932\u0928) \u0914\u0930 \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0928\u0941\u0938\u0942\u091a\u0940\u0915\u0930\u0923 (\u0928\u093f\u092e\u094d\u0928-\u0915\u0930\u094d\u0924\u0935\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915\/\u0905\u0930\u094d\u0927-\u0935\u093e\u0930\u094d\u0937\u093f\u0915\/\u0935\u093e\u0930\u094d\u0937\u093f\u0915) \u0915\u0947 \u092c\u0940\u091a \u0938\u0902\u0924\u0941\u0932\u0928 \u092c\u0928\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 \u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930 \u0924\u0924\u094d\u0915\u093e\u0932 \u0905\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/figcaption><\/figure>\n\n\n\n<p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0938\u0902\u091a\u093e\u0932\u0928 \u0926\u093e\u092f\u093f\u0924\u094d\u0935, \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u0914\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u094b\u0902 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u091c\u092c \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901 \u092c\u0926\u0932\u0924\u0940 \u0939\u094b\u0902, \u0924\u094b \u0905\u0927\u093f\u0915 \u0938\u0924\u0930\u094d\u0915 \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0905\u0902\u0924\u0930\u093e\u0932 \u0926\u093f\u0936\u093e\u0928\u093f\u0930\u094d\u0926\u0947\u0936:<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"time-based-intervals\">\u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0902\u0924\u0930\u093e\u0932<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 (3 \u092e\u0939\u0940\u0928\u0947)<\/strong>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923, \u0938\u092b\u093e\u0908, \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a<\/li>\n\n\n\n<li><strong>\u0905\u0930\u094d\u0927-\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (6 \u092e\u0939\u0940\u0928\u0947)<\/strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928, \u0938\u092e\u092f-\u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/li>\n\n\n\n<li><strong>\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (12 \u092e\u0939\u0940\u0928\u0947)<\/strong>: \u092a\u0942\u0930\u094d\u0923 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u091c\u093e\u0901\u091a, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/li>\n\n\n\n<li><strong>\u0926\u094d\u0935\u093f\u0935\u093e\u0930\u094d\u0937\u093f\u0915 (24 \u092e\u0939\u0940\u0928\u0947)<\/strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e, \u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u092b\u093c\u0902\u0915\u094d\u0936\u0928, \u0938\u0939\u093e\u092f\u0915 \u092a\u0930\u093f\u092a\u0925 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0938\u0939\u093f\u0924 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operation-based-intervals\">\u0938\u0902\u091a\u093e\u0932\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0902\u0924\u0930\u093e\u0932<\/h3>\n\n\n\n<p>\u0909\u091a\u094d\u091a-\u0921\u094d\u092f\u0942\u091f\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0905\u0927\u093f\u0915 \u0938\u091f\u0940\u0915:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 5,000 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 10,000 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>: \u092a\u0942\u0930\u094d\u0923 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 + \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 20,000 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>: \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 50,000 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>: \u092e\u093e\u092a\u094b\u0902 \u0915\u0940 \u092a\u0930\u0935\u093e\u0939 \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0915\u0948\u0938\u0947 \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0915\u093e\u0909\u0902\u091f\u0930 (\u092f\u0926\u093f \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0939\u094b\u0902)<\/li>\n\n\n\n<li>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u093e\u0909\u0902\u091f\u0930<\/li>\n\n\n\n<li>SCADA\/DCS \u0932\u0949\u0917\u094d\u0938<\/li>\n\n\n\n<li>\u092e\u0948\u0928\u0941\u0905\u0932 \u0932\u0949\u0917 \u0936\u0940\u091f\u094d\u0938 (\u0938\u092c\u0938\u0947 \u0915\u092e \u0938\u091f\u0940\u0915 \u0932\u0947\u0915\u093f\u0928 \u0915\u0941\u091b \u0928\u0939\u0940\u0902 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092c\u0947\u0939\u0924\u0930)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"condition-based-triggers\">\u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930<\/h3>\n\n\n\n<p>\u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0905\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0909\u0902\u0938 \u0926\u0947\u0916\u093e \u0917\u092f\u093e (\u092c\u0902\u0926 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0938\u0941\u0928\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0940 \u0916\u091f\u0916\u091f)<\/li>\n\n\n\n<li>\u0935\u093f\u0938\u094d\u0924\u093e\u0930\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u092e\u092f \u0926\u0947\u0916\u093e \u0917\u092f\u093e<\/li>\n\n\n\n<li>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0936\u094b\u0930 \u092f\u093e \u0915\u0902\u092a\u0928<\/li>\n\n\n\n<li>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u092f\u093e \u092c\u0902\u0926\/\u091f\u094d\u0930\u093f\u092a \u0928 \u0939\u094b\u0928\u0947 \u0915\u094b \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u092c\u093e\u0939\u0930\u0940 \u0918\u091f\u0915\u094b\u0902 \u092e\u0947\u0902 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u093e \u0930\u0902\u0917 \u0915\u093e \u092c\u0926\u0932\u0928\u093e \u092f\u093e \u0915\u094d\u0937\u0924\u093f<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact-resistance-measurement\">\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928<\/h2>\n\n\n\n<p>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0938\u0940\u0927\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923 \u0914\u0930 \u0938\u0924\u0939 \u0938\u0902\u0926\u0942\u0937\u0923 \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u091c\u0948\u0938\u0947-\u091c\u0948\u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0918\u093f\u0938\u093e\u0935 \u0939\u094b\u0924\u093e \u0939\u0948, \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0922\u093c\u0924\u093e \u0939\u0948\u2014\u091c\u093f\u0938\u0938\u0947 \u0927\u093e\u0930\u093e \u0915\u094d\u0937\u092e\u0924\u093e \u0918\u091f\u0924\u0940 \u0939\u0948 \u0914\u0930 I\u00b2R \u0939\u0940\u091f\u093f\u0902\u0917 \u092c\u0922\u093c\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-it-matters\">\u092f\u0939 \u0915\u094d\u092f\u094b\u0902 \u092e\u093e\u092f\u0928\u0947 \u0930\u0916\u0924\u093e \u0939\u0948<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e<\/strong>\u0918\u093f\u0938\u0947 \u0939\u0941\u090f \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948 \u2192 \u0909\u091a\u094d\u091a \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/li>\n\n\n\n<li><strong>\u0905\u0924\u093f \u0924\u093e\u092a \u091c\u094b\u0916\u093f\u092e<\/strong>\u092c\u0922\u093c\u093e \u0939\u0941\u0906 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u090a\u0937\u094d\u092e\u093e \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 (P = I\u00b2R), \u091c\u093f\u0938\u0938\u0947 \u0935\u093f\u092b\u0932\u0924\u093e \u092e\u0947\u0902 \u0924\u0947\u091c\u0940 \u0906\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li><strong>\u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093e\u0924\u094d\u092e\u0915 \u0938\u0902\u0915\u0947\u0924\u0915<\/strong>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0936\u0947\u0937 \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u0940\u0935\u0928 \u0915\u093e \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928 \u0932\u0917\u093e\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"equipment-required\">\u0906\u0935\u0936\u094d\u092f\u0915 \u0909\u092a\u0915\u0930\u0923<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930<\/strong>&nbsp;(100 \u090f \u092f\u093e 200 \u090f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924)\n<ul class=\"wp-block-list\">\n<li>\u0928\u093f\u092e\u094d\u0928 \u0927\u093e\u0930\u093e\u090f\u0901 (10 \u090f) \u0938\u0924\u0939\u0940 \u092b\u093f\u0932\u094d\u092e \u092a\u094d\u0930\u092d\u093e\u0935\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0915\u092e \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u092e\u093e\u092a \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0915\u0947\u0932\u094d\u0935\u093f\u0928 (4-\u0924\u093e\u0930) \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0932\u0940\u0921 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928 \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/strong>&nbsp;\u092a\u093f\u091b\u0932\u0947 12 \u092e\u0939\u0940\u0928\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930<\/li>\n\n\n\n<li><strong>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0909\u092a\u0915\u0930\u0923<\/strong>\u0906\u0930\u094d\u0915 \u092b\u094d\u0932\u0948\u0936 \u092a\u0940\u092a\u0940\u0908, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0909\u092a\u0915\u0930\u0923<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"procedure\">\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915\u0915 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0947\u0902<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091f\u0947\u0938\u094d\u091f\u0930 \u0938\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u0932\u093e\u0917\u0942 \u0939\u094b \u0924\u094b \u0930\u0948\u0915 \u0938\u0947 \u092c\u093e\u0939\u0930 \u0928\u093f\u0915\u0932\u0947\u0902\/\u0935\u093e\u092a\u0938 \u0932\u0947\u0902<\/li>\n\n\n\n<li>\u091f\u0948\u0917 \u0906\u0909\u091f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925<\/li>\n\n\n\n<li>\u0921\u093f\u0938\u094d\u091a\u093e\u0930\u094d\u091c \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 (\u092f\u0926\u093f \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0939\u094b)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0924\u0939\u094b\u0902 \u092a\u0930 \u0915\u0947\u0932\u094d\u0935\u093f\u0928 \u0915\u094d\u0932\u093f\u092a\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0905\u091a\u094d\u091b\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 (\u092f\u0926\u093f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902)<\/li>\n\n\n\n<li>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u094b\u0932 \u0915\u094b \u0905\u0932\u0917-\u0905\u0932\u0917 \u092e\u093e\u092a\u0947\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u092a\u0920\u0928 \u0915\u094b \u0938\u094d\u0925\u093f\u0930 \u0939\u094b\u0928\u0947 \u0926\u0947\u0902 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 5\u201310 \u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li>\u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e (\u03bc\u03a9) \u092e\u0947\u0902 \u092e\u093e\u0928 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0914\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0938\u092d\u0940 \u0927\u094d\u0930\u0941\u0935\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0926\u094b\u0939\u0930\u093e\u090f\u0901<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0924\u0940\u0928\u094b\u0902 \u091a\u0930\u0923\u094b\u0902 (\u092f\u093e \u0932\u093e\u0917\u0942 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094b\u0932\u094b\u0902 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e) \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902 (\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u0947 \u0938\u093e\u0925 \u092c\u0926\u0932\u0924\u093e \u0939\u0948)<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"acceptance-criteria\">\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092e\u093e\u0928\u0926\u0902\u0921<\/h3>\n\n\n\n<p><strong>\u092a\u0930\u092e \u0938\u0940\u092e\u093e\u090f\u0901<\/strong>&nbsp;(12\u201338 kV \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u092e\u093e\u0928\u094d\u092f):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0928\u090f \u0938\u0902\u092a\u0930\u094d\u0915<\/strong>: 50\u2013150 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e \u092a\u094d\u0930\u0924\u093f \u092a\u094b\u0932<\/li>\n\n\n\n<li><strong>\u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e<\/strong>: 300 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e \u0905\u0927\u093f\u0915\u0924\u092e<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0940\u092e\u093e<\/strong>: &gt;250 \u03bc\u03a9 \u092f\u093e \u092e\u0942\u0932 \u0906\u0927\u093e\u0930\u0930\u0947\u0916\u093e \u0915\u093e 3\u00d7<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u093e\u092a\u0947\u0915\u094d\u0937 \u0938\u0940\u092e\u093e\u090f\u0901:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0938\u0947 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u0947\u0902 50% \u0938\u0947 \u0905\u0927\u093f\u0915 \u0935\u0943\u0926\u094d\u0927\u093f \u2192 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0927\u094d\u0930\u0941\u0935-\u0938\u0947-\u0927\u094d\u0930\u0941\u0935 \u092d\u093f\u0928\u094d\u0928\u0924\u093e &gt;30% \u2192 \u0905\u0938\u092e\u093e\u0928 \u0918\u093f\u0938\u093e\u0935 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948<\/li>\n\n\n\n<li>\u0905\u091a\u093e\u0928\u0915 \u0909\u091b\u093e\u0932 (&gt;20% \u0905\u0902\u0924\u0930\u093e\u0932\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a) \u2192 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0947 \u0932\u093f\u090f \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902, \u092f\u0939 \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u093e\u0935 \u0915\u0940 \u092c\u091c\u093e\u092f \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0909\u0926\u093e\u0939\u0930\u0923 \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0916\u0902\u092d\u093e<\/th><th>\u092c\u0947\u0938\u0932\u093e\u0907\u0928 (\u0928\u092f\u093e)<\/th><th>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u092a\u0920\u0928<\/th><th>\u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928<\/th><\/tr><\/thead><tbody><tr><td>A<\/td><td>80 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>120 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>\u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f (+50%, \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0918\u093f\u0938\u093e\u0935)<\/td><\/tr><tr><td>B<\/td><td>85 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>135 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>\u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f (+59%, \u092c\u093e\u0930\u0940\u0915\u0940 \u0938\u0947 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902)<\/td><\/tr><tr><td>C<\/td><td>82 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>210 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0906\u0935\u0936\u094d\u092f\u0915<\/strong>&nbsp;(+156%, \u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e \u0915\u0947 \u0915\u0930\u0940\u092c)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u092a\u094b\u0932 C \u092a\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0918\u093f\u0938\u093e\u0935\u091f \u0939\u0948\u2014\u0905\u0917\u0932\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0916\u093f\u0921\u093c\u0915\u0940 \u092e\u0947\u0902 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u090f\u0901\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement.webp\" alt=\"4-\u0924\u093e\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0935\u093e\u0932\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u0915\u0947\u0932\u094d\u0935\u093f\u0928 \u0915\u094d\u0932\u093f\u092a \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0941\u0906 \u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0938\u0947\u091f\u0905\u092a, \u091c\u093f\u0938\u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0930\u0940\u0921\u093f\u0902\u0917 \u0921\u093f\u0938\u094d\u092a\u094d\u0932\u0947 \u0939\u0948\u0964\" class=\"wp-image-2513\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0906\u0915\u0943\u0924\u093f 1**: \u0915\u0947\u0932\u094d\u0935\u093f\u0928 (4-\u0924\u093e\u0930) \u0915\u094d\u0932\u093f\u092a\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 100A+ \u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u2014\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e \u0938\u0924\u0939\u0940 \u0911\u0915\u094d\u0938\u093e\u0907\u0921 \u092b\u093f\u0932\u094d\u092e\u094b\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0930\u0915\u0947 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0927\u093e\u0924\u0941-\u0938\u0947-\u0927\u093e\u0924\u0941 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u092e\u093e\u092a\u0924\u0940 \u0939\u0948, \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 &lt;250 \u03bc\u03a9, \u091c\u094b \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-integrity-check\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u091c\u093e\u0901\u091a<\/h2>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 10\u207b\u2074 Pa (10\u207b\u2076 \u091f\u0949\u0930) \u0938\u0947 \u0928\u0940\u091a\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0926\u092c\u093e\u0935 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0935\u0930\u094d\u0937\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092e\u0947\u0902 \u0917\u093f\u0930\u093e\u0935\u091f \u0917\u0948\u0938 \u0905\u0923\u0941\u0913\u0902 \u0915\u094b \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0905\u0935\u0930\u094b\u0927 \u0915\u094d\u0937\u092e\u0924\u093e \u092e\u0947\u0902 \u0915\u092e\u0940 \u0906\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-vacuum-degrades\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u092f\u094b\u0902 \u092c\u093f\u0917\u0921\u093c\u0924\u093e \u0939\u0948<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u0938\u0930\u0923<\/strong>\u0939\u0940\u0932\u093f\u092f\u092e \u0914\u0930 \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u091c\u0928 \u092a\u0930\u092e\u093e\u0923\u0941 \u0938\u093f\u0930\u0947\u092e\u093f\u0915-\u0927\u093e\u0924\u0941 \u0938\u0940\u0932 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u092a\u094d\u0930\u0935\u093e\u0939\u093f\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0938\u0942\u0915\u094d\u0937\u094d\u092e-\u0932\u0940\u0915<\/strong>\u0924\u093e\u092a\u0940\u092f \u091a\u0915\u094d\u0930\u0923 \u0938\u0947 \u092c\u094d\u0930\u0947\u091c \u091c\u094b\u0921\u093c \u092e\u0947\u0902 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0926\u0930\u093e\u0930\u0947\u0902 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0906\u0902\u0924\u0930\u093f\u0915 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928<\/strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0947 \u0915\u094d\u0937\u0930\u0923 \u0927\u093e\u0924\u0941 \u0935\u093e\u0937\u094d\u092a \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091d\u091f\u0915\u093e<\/strong>: \u0915\u0902\u092a\u0928 \u092f\u093e \u0906\u0918\u093e\u0924 \u0938\u0940\u0932 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928 \u092a\u0939\u0941\u0901\u091a\u093e \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p>\u0918\u091f\u093f\u0924 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0924\u0941\u0930\u0902\u0924 \u0935\u093f\u092b\u0932\u0924\u093e \u0928\u0939\u0940\u0902 \u0932\u093e\u0924\u093e\u2014\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0940 \u092d\u093e\u0930\u094b\u0902 \u0915\u094b \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u093e \u091c\u093e\u0930\u0940 \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964 \u0932\u0947\u0915\u093f\u0928 \u0926\u094b\u0937 \u0935\u093f\u091a\u094d\u091b\u0947\u0926\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0918\u091f \u091c\u093e\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0907\u0928\u0930\u0936 \u0927\u093e\u0930\u093e\u0913\u0902 \u092f\u093e \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091c\u094b\u0916\u093f\u092e \u092a\u0948\u0926\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"test-methods\">\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093f\u0927\u093f\u092f\u093e\u0901<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-1-high-voltage-proof-test-most-reliable\">\u0935\u093f\u0927\u093f 1: \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0942\u092b\u093c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0938\u092c\u0938\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f)<\/h4>\n\n\n\n<p>\u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u090f\u0938\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0930\u093f\u0938\u093e\u0935 \u0927\u093e\u0930\u093e \u0915\u094b \u092e\u093e\u092a\u0947\u0902 \u092f\u093e \u092c\u094d\u0930\u0947\u0915\u0921\u093e\u0909\u0928 \u0915\u093e \u0905\u0935\u0932\u094b\u0915\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0909\u092a\u0915\u0930\u0923:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u090f\u0938\u0940 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947\u091f (\u0938\u092e\u093e\u092f\u094b\u091c\u094d\u092f 10\u201350 kV)<\/li>\n\n\n\n<li>\u0927\u093e\u0930\u093e-\u0938\u0940\u092e\u093f\u0924 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0915<\/li>\n\n\n\n<li>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0935\u0930\u094b\u0927\u0915 \u0914\u0930 \u092a\u0940\u092a\u0940\u0908<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915\u0915\u0930\u094d\u0924\u093e \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0916\u0941\u0932 \u091c\u093e\u090f\u0901 (\u092f\u0926\u093f \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0947\u0902)<\/li>\n\n\n\n<li>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0930\u0947\u091f\u0947\u0921 BIL \u0915\u093e 70\u201380%)<\/li>\n\n\n\n<li>1 \u092e\u093f\u0928\u091f \u0924\u0915 \u0930\u094b\u0915\u0947\u0902<\/li>\n\n\n\n<li>\u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u092f\u093e \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0930\u093f\u0938\u093e\u0935 \u0927\u093e\u0930\u093e \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0928 \u0939\u094b\u0928\u093e = \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0915\u094d\u0937\u0941\u0923\u094d\u0923<\/li>\n\n\n\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0947 \u0928\u0940\u091a\u0947 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 = \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0916\u0924\u094d\u092e, \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0940\u092e\u093e\u090f\u0901:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u092a\u0915\u0930\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948 (\u091c\u094b \u0939\u092e\u0947\u0936\u093e \u0938\u093e\u0907\u091f \u092a\u0930 \u0909\u092a\u0932\u092c\u094d\u0927 \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u093e)<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092a\u0939\u0932\u0947 \u0938\u0947 \u0939\u0940 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0939\u094b \u091a\u0941\u0915\u093e \u0939\u0948 \u0924\u094b \u0914\u0930 \u0905\u0927\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u091c\u094b\u0916\u093f\u092e\u0964<\/li>\n\n\n\n<li>\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u094b \u0906\u0907\u0938\u094b\u0932\u0947\u091f \u0914\u0930 \u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c \u0915\u0930\u0915\u0947 \u0939\u0940 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-2-contact-gap-withstand-voltage-test\">\u0935\u093f\u0927\u093f 2: \u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0948\u092a \u0938\u0939\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h4>\n\n\n\n<p>\u0935\u093f\u0927\u093f 1 \u0915\u0947 \u0938\u092e\u093e\u0928, \u0932\u0947\u0915\u093f\u0928 \u092e\u093e\u0928\u0915 \u092e\u0947\u0917\u0930 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0947\u0938\u094d\u091f\u0930\u094b\u0902 \u0938\u0947 \u0909\u092a\u0932\u092c\u094d\u0927 \u0915\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0947\u0938\u094d\u091f\u0930 \u0938\u0947 \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 1,000 V DC \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0905\u091a\u094d\u091b\u093e \u0935\u094b\u0932\u094d\u091f\u0947\u091c: &gt;100 M\u03a9 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0938\u094d\u0925\u093f\u0930 \u0930\u0940\u0921\u093f\u0902\u0917<\/li>\n\n\n\n<li>\u0935\u093f\u092b\u0932 \u0935\u0948\u0915\u094d\u092f\u0942\u092e: \u0915\u092e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092f\u093e \u0905\u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0940\u0921\u093f\u0902\u0917, \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0932\u093e\u092d:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0906\u092e \u0924\u094c\u0930 \u092a\u0930 \u0909\u092a\u0932\u092c\u094d\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924, \u0938\u0930\u0932 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0940\u092e\u093e\u090f\u0901:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u092e \u0928\u093f\u0936\u094d\u091a\u093f\u0924<\/li>\n\n\n\n<li>\u092e\u0927\u094d\u092f\u092e \u0914\u0930 \u0917\u0902\u092d\u0940\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0939\u093e\u0928\u093f \u0915\u0947 \u092c\u0940\u091a \u0905\u0902\u0924\u0930 \u0928\u0939\u0940\u0902 \u0915\u0930 \u0938\u0915\u0924\u0947<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-3-contact-travel-measurement-indirect-indicator\">\u0935\u093f\u0927\u093f 3: \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u093e\u092a\u0928 (\u0905\u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0938\u0902\u0915\u0947\u0924\u0915)<\/h4>\n\n\n\n<p>\u092f\u0939 \u0938\u0940\u0927\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u0939\u0940\u0902 \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0938\u094d\u092a\u0930\u094d\u0936 \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0928\u0940\u091a\u0947 \u0939\u094b\u0928\u093e \u0905\u0915\u094d\u0938\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0939\u093e\u0928\u093f \u0938\u0947 \u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948 (\u091c\u092c \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 \u0914\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0926\u092c\u093e\u0935 \u092c\u0930\u093e\u092c\u0930 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0938\u0902\u092a\u0930\u094d\u0915 \u0925\u094b\u0921\u093c\u0947 \u091a\u093f\u092a\u0915 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902)\u0964.<\/p>\n\n\n\n<p><strong>\u0906\u0927\u093e\u0930\u092d\u0942\u0924 \u092f\u093e\u0924\u094d\u0930\u093e:<\/strong>&nbsp;\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u090f\u092e\u0935\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f 8\u201312 \u092e\u093f\u092e\u0940<br><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0938\u094d\u0924\u0930:<\/strong>&nbsp;\u0930\u0947\u091f\u093f\u0902\u0917 \u091f\u094d\u0930\u0948\u0935\u0932 \u0915\u093e 80% \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0916\u0930\u093e\u092c\u0940 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947 \u0938\u0915\u0924\u093e \u0939\u0948\u0964<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-4-infrared-thermography-during-operation-advanced\">\u0935\u093f\u0927\u093f 4: \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0935\u0930\u0915\u094d\u0924 \u0925\u0930\u094d\u092e\u094b\u0917\u094d\u0930\u093e\u092b\u0940 (\u0909\u0928\u094d\u0928\u0924)<\/h4>\n\n\n\n<p>\u0935\u093f\u092b\u0932 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0947 \u0915\u093e\u0930\u0923 \u0905\u0935\u0930\u094b\u0927 \u0915\u094d\u0937\u092e\u0924\u093e \u092e\u0947\u0902 \u0915\u092e\u0940 \u0914\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0902\u092a\u0930\u094d\u0915 \u0924\u093e\u092a \u092c\u0922\u093c \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092d\u093e\u0930 \u0915\u0947 \u0924\u0939\u0924 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0914\u0930 \u0924\u0941\u0930\u0902\u0924 \u092c\u093e\u0926 \u0925\u0930\u094d\u092e\u0932 \u091b\u0935\u093f \u0915\u0948\u092a\u094d\u091a\u0930 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0925\u0930\u094d\u092e\u0932 \u0938\u093f\u0917\u094d\u0928\u0947\u091a\u0930 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0947 \u0938\u0902\u0915\u0947\u0924:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0906\u0927\u093e\u0930\u0930\u0947\u0916\u093e \u0938\u0947 30\u00b0C \u0938\u0947 \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e<\/li>\n\n\n\n<li>\u0927\u094d\u0930\u0941\u0935\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0905\u0938\u092e\u093e\u0928 \u0924\u093e\u092a<\/li>\n\n\n\n<li>\u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0949\u0921\u0940 \u092a\u0930 \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0917\u0930\u094d\u092e \u0938\u094d\u0925\u093e\u0928<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0932\u093e\u092d:<\/strong>&nbsp;\u0917\u0948\u0930-\u0906\u0915\u094d\u0930\u093e\u092e\u0915, \u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964<br><strong>\u0938\u0940\u092e\u093e:<\/strong>&nbsp;\u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u0921\u0947\u091f\u093e \u0914\u0930 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0925\u0930\u094d\u092e\u094b\u0917\u094d\u0930\u093e\u092b\u0930 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"recommended-practice\">\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0905\u092d\u094d\u092f\u093e\u0938<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0935\u093e\u0930\u094d\u0937\u093f\u0915<\/strong>\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093f\u0927\u093f 2 (\u0938\u0902\u092a\u0930\u094d\u0915 \u0917\u0948\u092a \u092a\u0930\u0940\u0915\u094d\u0937\u0923) \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0939\u0930 2\u20133 \u0938\u093e\u0932 \u092e\u0947\u0902<\/strong>\u092f\u0926\u093f \u0909\u092a\u0915\u0930\u0923 \u0909\u092a\u0932\u092c\u094d\u0927 \u0939\u094b \u0924\u094b \u0935\u093f\u0927\u093f 1 (\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923) \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0932\u0917\u093e\u0924\u093e\u0930<\/strong>&nbsp;(\u092f\u0926\u093f \u0938\u0902\u092d\u0935 \u0939\u094b): \u0928\u093f\u092f\u092e\u093f\u0924 \u0926\u094c\u0930\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093f\u0927\u093f 4 (\u0925\u0930\u094d\u092e\u094b\u0917\u094d\u0930\u093e\u092b\u0940) \u0938\u0947 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-to-do-if-vacuum-is-lost\">\u092f\u0926\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0916\u094b \u091c\u093e\u090f \u0924\u094b \u0915\u094d\u092f\u093e \u0915\u0930\u0947\u0902<\/h3>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0915\u094b \u092b\u0940\u0932\u094d\u0921 \u092e\u0947\u0902 \u092e\u0930\u092e\u094d\u092e\u0924 \u092f\u093e \u092a\u0941\u0928\u0903 \u0928\u093f\u0930\u094d\u0935\u093e\u0924 \u0928\u0939\u0940\u0902 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e\u0964 \u090f\u0915\u092e\u093e\u0924\u094d\u0930 \u0935\u093f\u0915\u0932\u094d\u092a:&nbsp;<strong>\u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928<\/strong>.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0928\u093f\u0930\u094d\u0923\u092f \u0935\u0943\u0915\u094d\u0937:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u092a\u0941\u0937\u094d\u091f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0935\u093f\u092b\u0932\u0924\u093e \u2192 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094b \u0924\u0941\u0930\u0902\u0924 \u092c\u0926\u0932\u0947\u0902 (\u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0935\u093e\u092a\u0938 \u0928 \u0915\u0930\u0947\u0902)<\/li>\n\n\n\n<li>\u0938\u0940\u092e\u093e\u0902\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e \u2192 \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902, \u0905\u0917\u0932\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0905\u091a\u094d\u091b\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u0930\u093f\u0923\u093e\u092e \u2192 \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0935\u093e\u092a\u0938\u0940, \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0905\u0902\u0924\u0930\u093e\u0932 \u092a\u0930 \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/li>\n<\/ol>\n\n\n\n<p>\u0938\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u00a0<a href=\"https:\/\/xbrele.com\/hi\/switchgear-component-manufacturer\/\" data-type=\"page\" data-id=\"1967\">\u092f\u094b\u0917\u094d\u092f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e<\/a>\u00a0\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0915\u0930\u0902\u091f \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 $200\u2013$800 \u0915\u0940 \u0932\u093e\u0917\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0930\u0932 \u0939\u0948\u2014\u0905\u0927\u093f\u0915\u093e\u0902\u0936 \u0921\u093f\u091c\u093c\u093e\u0907\u0928\u094b\u0902 \u092e\u0947\u0902 \u092a\u0942\u0930\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u094b \u0935\u093f\u0918\u091f\u093f\u0924 \u0915\u093f\u090f \u092c\u093f\u0928\u093e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0915\u094b \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mechanical-inspection\">\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h2>\n\n\n\n<p>\u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u092e\u0947\u0902 \u092c\u0947\u092f\u0930\u093f\u0902\u0917, \u0932\u093f\u0902\u0915, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0914\u0930 \u0932\u0948\u091a \u0936\u093e\u092e\u093f\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0918\u093f\u0938\u093e\u0935, \u091c\u0902\u0917 \u0914\u0930 \u0938\u0902\u0930\u0947\u0916\u0923\u0939\u0940\u0928\u0924\u093e \u0915\u0947 \u0905\u0927\u0940\u0928 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u0905\u0915\u094d\u0938\u0930 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0947 \u092a\u0939\u0932\u0947 \u091a\u0947\u0924\u093e\u0935\u0928\u0940 \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"inspection-points\">\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092c\u093f\u0902\u0926\u0941<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"1.-operating-mechanism-condition\">1. \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f<\/h4>\n\n\n\n<p><strong>\u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0924\u0947\u0932 \u0938\u0942\u0916 \u0917\u092f\u093e \u092f\u093e \u0927\u0942\u0932 \u0938\u0947 \u0926\u0942\u0937\u093f\u0924 \u0939\u094b \u0917\u092f\u093e<\/li>\n\n\n\n<li>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u091a\u093f\u0915\u0928\u093e\u0908 \u0917\u0902\u0926\u0917\u0940 \u0915\u094b \u0906\u0915\u0930\u094d\u0937\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0924\u093e\u092a\u092e\u093e\u0928-\u0905\u0928\u0941\u0915\u0942\u0932 \u0928\u0939\u0940\u0902 \u091a\u093f\u0915\u0928\u093e\u0908 (\u0920\u0902\u0921 \u092e\u0947\u0902 \u0915\u0920\u094b\u0930, \u0917\u0930\u094d\u092e\u0940 \u092e\u0947\u0902 \u0924\u0930\u0932)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0938\u093e\u092b \u0915\u0930\u0947\u0902 \u0914\u0930 \u092a\u0941\u0928\u0903 \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0909\u091a\u093f\u0924 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u093e \u091a\u093f\u0915\u0928\u093e\u0908 \u092a\u0926\u093e\u0930\u094d\u0925 \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 -40\u00b0C \u0938\u0947 +125\u00b0C \u0924\u0915 \u0930\u0947\u091f\u0947\u0921 \u0932\u093f\u0925\u093f\u092f\u092e-\u0906\u0927\u093e\u0930\u093f\u0924 \u0917\u094d\u0930\u0940\u0938)<\/li>\n\n\n\n<li>\u0915\u092e \u092e\u093e\u0924\u094d\u0930\u093e \u092e\u0947\u0902 \u0932\u0917\u093e\u090f\u0901\u2014\u0905\u0927\u093f\u0915 \u092e\u093e\u0924\u094d\u0930\u093e \u092e\u0947\u0902 \u0917\u0902\u0926\u0917\u0940 \u091a\u093f\u092a\u0915\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935\u091f<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u092a\u093f\u0935\u091f \u092a\u0949\u0907\u0902\u091f\u094d\u0938 \u0932\u092e\u094d\u092c\u0940 \u092f\u093e \u0905\u0902\u0921\u093e\u0915\u093e\u0930 \u092d\u093e\u0930 \u0935\u0939\u0928 \u0938\u0924\u0939\u094b\u0902 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0932\u093f\u0902\u0915\u0947\u091c \u092a\u093f\u0928\u094b\u0902 \u092e\u0947\u0902 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0922\u0940\u0932\u093e\u092a\u0928 \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u092f\u0940 \u0935\u093f\u0915\u0943\u0924\u093f \u092f\u093e \u0926\u0930\u093e\u0930\u0947\u0902 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0947 \u092a\u0939\u0932\u0947 \u0918\u093f\u0938\u0947 \u0939\u0941\u090f \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u092c\u0926\u0932\u0947\u0902<\/li>\n\n\n\n<li>\u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u0930\u094d\u0924\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u092a\u0947\u092f\u0930 \u0932\u093f\u0902\u0915\u091c \u0915\u093f\u091f \u0915\u093e \u0938\u094d\u091f\u0949\u0915 \u0930\u0916\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u0930\u0947\u0916\u0923<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u092d\u0941\u091c\u093e\u090f\u0901 \u092c\u093f\u0928\u093e \u0905\u091f\u0915\u0928\u0947 \u0938\u0940\u0927\u0947 \u091a\u0932\u0924\u0940 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0916\u0941\u0932\u0947 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0924\u0940\u0928\u094b\u0902 \u0927\u094d\u0930\u0941\u0935\u094b\u0902 \u092a\u0930 \u0938\u092e\u093e\u0928 \u0917\u0948\u092a<\/li>\n\n\n\n<li>\u092f\u0902\u0924\u094d\u0930 \u092e\u0947\u0902 \u0915\u094b\u0908 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u093e \u0935\u093f\u0915\u094d\u0937\u0947\u092a\u0923 \u092f\u093e \u092e\u094b\u0921\u093c \u0928\u0939\u0940\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092f\u0926\u093f \u0924\u0902\u0924\u094d\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 \u092a\u094d\u0930\u093e\u0935\u0927\u093e\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u0924\u094b \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092f\u0926\u093f \u092e\u0941\u0921\u093c\u0947 \u092f\u093e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0939\u094b\u0902, \u0924\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0918\u091f\u0915\u094b\u0902 \u0915\u094b \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"2.-contact-travel-and-timing\">2. \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0914\u0930 \u0938\u092e\u092f<\/h4>\n\n\n\n<p><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u093e\u092a:<\/strong><\/p>\n\n\n\n<p><strong>\u0909\u092a\u0915\u0930\u0923:<\/strong>&nbsp;\u0921\u093e\u0907\u0932 \u0938\u0902\u0915\u0947\u0924\u0915 \u092f\u093e \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u093e\u092a\u0928\u0947 \u0915\u093e \u0909\u092a\u0915\u0930\u0923<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915\u0915 \u0915\u094b \u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932\u0940 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0947\u0902 (\u092f\u0926\u093f \u0909\u092a\u0932\u092c\u094d\u0927 \u0939\u094b \u0924\u094b \u091f\u0947\u0938\u094d\u091f \u091c\u0948\u0915 \u092f\u093e \u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932 \u0932\u0940\u0935\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902)<\/li>\n\n\n\n<li>\u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u092c\u0902\u0926 \u0938\u0947 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0916\u0941\u0932\u0947 \u0924\u0915 \u0915\u0941\u0932 \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u093e\u092a\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0928\u0947\u092e\u092a\u094d\u0932\u0947\u091f \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0906\u092e \u092e\u093e\u0928:<\/strong>&nbsp;12 kV \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 8\u201312 \u092e\u093f\u092e\u0940, 24 kV \u0915\u0947 \u0932\u093f\u090f 10\u201315 \u092e\u093f\u092e\u0940<\/p>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0930\u0947\u091f\u093f\u0902\u0917 \u091f\u094d\u0930\u0948\u0935\u0932 \u0915\u093e 90\u2013110% = \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f<\/li>\n\n\n\n<li>&lt;90% = \u091c\u093e\u0902\u091a\u0947\u0902 (\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u0918\u093f\u0938\u093e\u0935\u091f \u092f\u093e \u0905\u0938\u092b\u0932 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0938\u0942\u091c\u0928\u093e)<\/li>\n\n\n\n<li>110% = \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u091f\u0949\u092a\u094d\u0938 \u092f\u093e \u0913\u0935\u0930-\u091f\u094d\u0930\u0948\u0935\u0932 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u092e\u092f \u092a\u0930\u0940\u0915\u094d\u0937\u0923:<\/strong><\/p>\n\n\n\n<p><strong>\u0909\u092a\u0915\u0930\u0923:<\/strong>&nbsp;\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092b\u093c\u0902\u0915\u094d\u0936\u0928 \u0935\u093e\u0932\u093e \u0939\u093e\u0908-\u0938\u094d\u092a\u0940\u0921 \u0930\u093f\u0915\u0949\u0930\u094d\u0921\u0930 \u092f\u093e \u0930\u093f\u0932\u0947 \u091f\u0947\u0938\u094d\u091f \u0938\u0947\u091f<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0930\u093f\u0915\u0949\u0930\u094d\u0921\u0930 \u0938\u0947 \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0915\u094d\u0932\u094b\u091c\u093f\u0902\u0917 \u0915\u0949\u0907\u0932 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u0949\u0907\u0932 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0939\u094b\u0928\u0947 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0924\u0915 \u0915\u093e \u0938\u092e\u092f \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0913\u092a\u0928\u093f\u0902\u0917 \u0915\u0949\u0907\u0932 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u0949\u0907\u0932 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0916\u0941\u0932\u0928\u0947 \u0924\u0915 \u0915\u093e \u0938\u092e\u092f \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0906\u092e \u0938\u092e\u093e\u092a\u0928 \u0938\u092e\u092f:<\/strong>&nbsp;50\u2013100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921<br><strong>\u0906\u092e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f:<\/strong>&nbsp;20\u201350 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921<\/p>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0915\u0947 \u00b110% \u0915\u0947 \u092d\u0940\u0924\u0930 = \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f<\/li>\n\n\n\n<li>\u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u0930\u092e\u093f\u0915 \u0935\u0943\u0926\u094d\u0927\u093f (\u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u090a\u092a\u0930 \u0915\u0940 \u0913\u0930 \u092c\u0922\u093c\u0928\u0947 \u0935\u093e\u0932\u093e \u0930\u0941\u091d\u093e\u0928) = \u0924\u0902\u0924\u094d\u0930 \u0915\u0947 \u0918\u093f\u0938\u093e\u0935, \u0938\u094d\u0928\u0947\u0939\u0928 \u092e\u0947\u0902 \u0917\u093f\u0930\u093e\u0935\u091f<\/li>\n\n\n\n<li>\u0905\u091a\u093e\u0928\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 (&gt;20%) = \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u092c\u093e\u0907\u0902\u0921\u093f\u0902\u0917, \u092f\u093e \u0918\u091f\u0915 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement.webp\" alt=\"\u0921\u093e\u092f\u0932 \u0907\u0902\u0921\u093f\u0915\u0947\u091f\u0930 \u0938\u0947 \u091c\u0941\u0921\u093c\u093e \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u093e\u092a\u0928 \u0938\u0947\u091f\u0905\u092a \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u094b \u0916\u0941\u0932\u0940 \u0938\u0947 \u092c\u0902\u0926 \u0938\u094d\u0925\u093f\u0924\u093f \u0924\u0915 \u092e\u093e\u092a\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 10.5 \u092e\u093f\u092e\u0940 \u092f\u093e\u0924\u094d\u0930\u093e \u0926\u0942\u0930\u0940 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964\" class=\"wp-image-2514\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0906\u0915\u0943\u0924\u093f 2**: \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u093e\u092a\u0928 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u0940 \u0938\u094d\u0935\u093e\u0938\u094d\u0925\u094d\u092f \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0921\u093e\u092f\u0932 \u0938\u0902\u0915\u0947\u0924\u0915 \u0915\u0941\u0932 \u0938\u094d\u091f\u094d\u0930\u094b\u0915 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 12 kV \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 8-12 \u092e\u093f\u092e\u0940) \u0915\u094b \u092e\u093e\u092a\u0924\u093e \u0939\u0948, \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925 \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u093e &lt;80% \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935 \u092f\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u091a\u093f\u092a\u0915\u0928\u0947 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"3.-auxiliary-contacts-and-interlocks\">3. \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0914\u0930 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938<\/h4>\n\n\n\n<p><strong>\u091c\u093e\u0901\u091a\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>: NO \u0914\u0930 NC \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093f\u0928\u093e \u091a\u091f\u0930 \u0915\u0947 \u0938\u094d\u0935\u091a\u094d\u091b \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0925\u093f\u0924\u093f \u092c\u0926\u0932\u0924\u0947 \u0939\u0948\u0902<\/li>\n\n\n\n<li><strong>\u092e\u0941\u0916\u094d\u092f \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0947 \u0938\u093e\u092a\u0947\u0915\u094d\u0937 \u0938\u092e\u092f<\/strong>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0939\u0940 \u0915\u094d\u0930\u092e \u092e\u0947\u0902 \u0939\u094b\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li><strong>\u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u092b\u093c\u0902\u0915\u094d\u0936\u0928<\/strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938 \u0905\u0938\u0902\u0917\u0924 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u090f\u0915 \u0938\u093e\u0925 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0932\u094d\u0921 \u0939\u094b\u0915\u0930 \u092c\u0902\u0926 (\u0905\u091f\u0915\u0947) \u0939\u0941\u090f<\/li>\n\n\n\n<li>\u091f\u0942\u091f\u0947 \u0939\u0941\u090f \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u091c\u094b \u0930\u0941\u0915-\u0930\u0941\u0915 \u0915\u0930 \u0915\u093e\u092e \u0915\u0930\u0928\u0947 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0905\u0938\u0902\u0930\u0947\u0916\u0923 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u092e\u092f\u092a\u0942\u0930\u094d\u0935 \u092f\u093e \u0935\u093f\u0932\u0902\u092c\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915\u0915 \u0915\u094b \u0939\u093e\u0925 \u0938\u0947 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902 \u0915\u093f \u0935\u0947 \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u0947 \u0938\u0939\u0940 \u092c\u093f\u0902\u0926\u0941 \u092a\u0930 \u0938\u094d\u0925\u093f\u0924\u093f \u092c\u0926\u0932\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u092e\u091c\u092c\u0942\u0924, \u0938\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902 (\u0915\u094b\u0908 \u0928\u0930\u092e \u092f\u093e \u0905\u0938\u094d\u092a\u0937\u094d\u091f \u0938\u0902\u0915\u094d\u0930\u092e\u0923 \u0928\u0939\u0940\u0902)<\/li>\n\n\n\n<li>\u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0917\u0932\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 (\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u094b\u0921 \u092e\u0947\u0902 \u091c\u093e\u0928\u092c\u0942\u091d\u0915\u0930 \u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0915\u093e \u0909\u0932\u094d\u0932\u0902\u0918\u0928 \u0915\u0930\u0928\u0947 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0915\u0930\u0947\u0902)<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"4.-arc-chutes-and-barriers\">4. \u0906\u0930\u094d\u0915 \u091a\u094d\u092f\u0942\u091f\u094d\u0938 \u0914\u0930 \u0905\u0935\u0930\u094b\u0927\u0915<\/h4>\n\n\n\n<p>\u0915\u0941\u091b \u0938\u0902\u092a\u0930\u094d\u0915\u0915\u094b\u0902 \u092e\u0947\u0902 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0932\u093f\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0947 \u091a\u093e\u0930\u094b\u0902 \u0913\u0930 \u0906\u0930\u094d\u0915 \u091a\u094d\u092f\u0942\u091f\u094d\u0938 \u092f\u093e \u0905\u0935\u0930\u094b\u0927\u0915 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u093f\u0902\u0917 \u0905\u0935\u0930\u094b\u0927\u094b\u0902 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902 \u092f\u093e \u0915\u094d\u0937\u0930\u0923<\/li>\n\n\n\n<li>\u0915\u093e\u0930\u094d\u092c\u0928 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 (\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u0938\u0924\u0939\u094b\u0902 \u092a\u0930 \u0915\u093e\u0932\u0947 \u091a\u093e\u0932\u0915 \u092e\u093e\u0930\u094d\u0917)<\/li>\n\n\n\n<li>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u093e \u0930\u0902\u0917 \u0915\u093e \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0906\u0907\u0938\u094b\u092a\u094d\u0930\u094b\u092a\u093e\u0907\u0932 \u0905\u0932\u094d\u0915\u094b\u0939\u0932 \u0914\u0930 \u0918\u0930\u094d\u0937\u0923 \u092a\u0948\u0921 \u0938\u0947 \u091f\u094d\u0930\u0948\u0915 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u091f\u0942\u091f\u0947 \u092f\u093e \u092c\u0939\u0941\u0924 \u0905\u0927\u093f\u0915 \u0926\u0930\u093e\u0930\u094b\u0902 \u0935\u093e\u0932\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u093e \u092e\u0942\u0932 \u0915\u093e\u0930\u0923 (\u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928, \u0905\u0927\u093f\u0915 \u092d\u093e\u0930, \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923) \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"coil-and-control-circuit-checks\">\u0915\u094b\u0907\u0932 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925 \u091c\u093e\u0901\u091a\u0947\u0902<\/h2>\n\n\n\n<p>\u0905\u091a\u094d\u091b\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093f\u090f \u0917\u090f \u0938\u093f\u0938\u094d\u091f\u092e \u092e\u0947\u0902 \u0911\u092a\u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u0949\u0907\u0932\u094d\u0938 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930\u094d\u0938 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"coil-resistance-measurement\">\u0915\u094b\u0907\u0932 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928<\/h3>\n\n\n\n<p><strong>\u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f:<\/strong>&nbsp;\u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u091f\u0930\u094d\u0928, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u091f\u0942\u091f\u0928\u0947, \u092f\u093e \u0915\u0949\u0907\u0932 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u090f\u0901\u0964<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0915\u094b\u0907\u0932 \u0932\u0940\u0921\u094d\u0938 \u0905\u0932\u0917 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u0941\u0902\u0921\u0932\u0940 \u0914\u0930 \u0916\u0941\u0932\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u0941\u0902\u0921\u0932\u0940 \u0915\u0947 \u092c\u0940\u091a \u0921\u0940\u0938\u0940 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0905\u0932\u0917-\u0905\u0932\u0917 \u092e\u093e\u092a\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092c\u0947\u0938\u0932\u093e\u0907\u0928 \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0915\u0947 \u00b110% \u0915\u0947 \u092d\u0940\u0924\u0930 = \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f<\/li>\n\n\n\n<li>\u0915\u093e\u092b\u0940 \u0915\u092e (&lt;20% \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0928\u0940\u091a\u0947) = \u0938\u0902\u092d\u0935\u0924\u0903 \u0936\u0949\u0930\u094d\u091f \u0939\u0941\u090f \u091f\u0930\u094d\u0928 \u2192 \u0915\u0949\u0907\u0932 \u092c\u0926\u0932\u0947\u0902<\/li>\n\n\n\n<li>\u0915\u093e\u092b\u0940 \u0905\u0927\u093f\u0915 (&gt;20% \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u090a\u092a\u0930) = \u0938\u0902\u092d\u0935\u0924\u0903 \u0916\u0941\u0932\u093e \u0938\u0930\u094d\u0915\u093f\u091f \u092f\u093e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"coil-insulation-resistance\">\u0915\u094b\u0907\u0932 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/h3>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0915\u094b\u0907\u0932 \u0935\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0914\u0930 \u0915\u094b\u0907\u0932 \u092b\u094d\u0930\u0947\u092e\/\u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0947 \u092c\u0940\u091a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0947\u0902\u0964<\/li>\n\n\n\n<li>500 V DC \u092e\u0947\u0917\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0906\u092e \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f\u0924\u093e: &gt;10 M\u03a9<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0928\u093f\u092e\u094d\u0928 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong>&nbsp;(&lt;1 M\u03a9) \u0928\u092e\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u0947\u0936 \u092f\u093e \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0915\u094b\u0907\u0932 \u0915\u094b \u0938\u0941\u0916\u093e\u090f\u0901 \u092f\u093e \u092c\u0926\u0932\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-voltage-verification\">\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/h3>\n\n\n\n<p>\u090f\u0938\u0940 \u092f\u093e \u0921\u0940\u0938\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c (110 V, 125 V, 220 V \u0906\u0926\u093f) \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u090f \u0917\u090f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0905\u0902\u0921\u0930-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0913\u0935\u0930-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0947 \u092a\u094d\u0930\u0924\u093f \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092e\u093e\u092a:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0949\u0907\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/li>\n\n\n\n<li>\u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c 85\u2013110% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0905\u0902\u0921\u0930-\u0935\u094b\u0932\u094d\u091f\u0947\u091c (&lt;85%):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0927\u0940\u092e\u0940 \u092f\u093e \u0905\u0927\u0942\u0930\u0940 \u0938\u092e\u093e\u092a\u094d\u0924\u093f<\/li>\n\n\n\n<li>\u0915\u094b\u0907\u0932 \u0915\u0940 \u0916\u091f\u0916\u091f (\u091a\u093e\u0932\u0942 \u0914\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u093e)<\/li>\n\n\n\n<li>\u0905\u0927\u0942\u0930\u0947 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092a\u0930\u093f\u092a\u0925 \u0938\u0902\u0932\u0917\u094d\u0928\u0924\u093e \u0915\u0947 \u0915\u093e\u0930\u0923 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0924\u093e\u092a<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0905\u0927\u093f-\u0935\u094b\u0932\u094d\u091f\u0947\u091c (&gt;110%):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092f\u0902\u0924\u094d\u0930\u0923\u093e \u092a\u0930 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0906\u0918\u093e\u0924 \u0924\u0928\u093e\u0935<\/li>\n\n\n\n<li>\u0915\u094b\u0907\u0932 \u0915\u093e \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u093e<\/li>\n\n\n\n<li>\u0938\u0902\u0915\u094d\u0937\u093f\u092a\u094d\u0924 \u0915\u0949\u0907\u0932 \u091c\u0940\u0935\u0928<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/strong>&nbsp;\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u092e\u0947\u0902\u2014\u0932\u0902\u092c\u0940 \u0915\u0947\u092c\u0932 \u0930\u0928\u094b\u0902 \u092f\u093e \u091b\u094b\u091f\u0947 \u0906\u0915\u093e\u0930 \u0915\u0947 \u091a\u093e\u0932\u0915\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0917\u093f\u0930\u093e\u0935\u091f \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"documentation-and-trending\">\u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0914\u0930 \u091f\u094d\u0930\u0947\u0902\u0921\u093f\u0902\u0917<\/h2>\n\n\n\n<p>\u092c\u093f\u0928\u093e \u0938\u0902\u0926\u0930\u094d\u092d \u0915\u0947 \u0915\u091a\u094d\u091a\u0947 \u092e\u093e\u092a \u092c\u0947\u0915\u093e\u0930 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0930\u0941\u091d\u093e\u0928\u0936\u0940\u0932 \u0921\u0947\u091f\u093e \u0917\u093f\u0930\u093e\u0935\u091f \u0915\u0947 \u092a\u0948\u091f\u0930\u094d\u0928 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-to-record\">\u0915\u094d\u092f\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902<\/h3>\n\n\n\n<p>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u0947 \u0932\u093f\u090f \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0926\u093f\u0928\u093e\u0902\u0915 \u0914\u0930 \u0938\u092e\u092f<\/strong>&nbsp;\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e<\/li>\n\n\n\n<li><strong>\u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u093e\u0909\u0902\u091f\u0930 \u0930\u0940\u0921\u093f\u0902\u0917<\/strong>&nbsp;(\u092f\u0926\u093f \u0909\u092a\u0932\u092c\u094d\u0927 \u0939\u094b)<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong>&nbsp;\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0927\u094d\u0930\u0941\u0935 \u0915\u0947 \u0932\u093f\u090f (\u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e \u092e\u0947\u0902)<\/li>\n\n\n\n<li><strong>\u092a\u0930\u093f\u0935\u0947\u0936 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928<\/strong>&nbsp;\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928<\/li>\n\n\n\n<li><strong>\u0938\u092e\u092f \u092e\u093e\u092a\u0928<\/strong>&nbsp;(\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f, \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902)<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e<\/strong>&nbsp;\u092e\u093e\u092a (\u092e\u093f\u092e\u0940 \u092e\u0947\u0902)<\/li>\n\n\n\n<li><strong>\u0926\u0943\u0936\u094d\u092f \u0905\u0935\u0932\u094b\u0915\u0928<\/strong>&nbsp;(\u0918\u093f\u0938\u093e\u0935, \u0915\u094d\u0937\u0930\u0923, \u0915\u094d\u0937\u0924\u093f)<\/li>\n\n\n\n<li><strong>\u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/strong>&nbsp;\u0915\u093f\u092f\u093e \u0917\u092f\u093e (\u0938\u092b\u093e\u0908, \u0938\u092e\u093e\u092f\u094b\u091c\u0928, \u092a\u0941\u0930\u094d\u091c\u0947 \u092c\u0926\u0932\u0947 \u0917\u090f)<\/li>\n\n\n\n<li><strong>\u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0915 \u0915\u093e \u0928\u093e\u092e\/\u0939\u0938\u094d\u0924\u093e\u0915\u094d\u0937\u0930<\/strong><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"trending-analysis\">\u092a\u094d\u0930\u091a\u0932\u0928 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/h3>\n\n\n\n<p>\u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u092a\u094d\u0930\u092e\u0941\u0916 \u092e\u093e\u092a\u0926\u0902\u0921\u094b\u0902 \u0915\u094b \u092a\u094d\u0932\u0949\u091f \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0928\u093e\u092e \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>: \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947, \u0930\u0948\u0916\u093f\u0915 \u092f\u093e \u0939\u0932\u094d\u0915\u093e \u0935\u0915\u094d\u0930\u093e\u0915\u093e\u0930 \u092c\u0922\u093c\u0928\u093e \u091a\u093e\u0939\u093f\u090f<\/li>\n\n\n\n<li><strong>\u0938\u092e\u092f \u092c\u0928\u093e\u092e \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>: \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0947 \u092a\u0941\u0930\u093e\u0928\u0947 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0925\u094b\u0921\u093c\u0940 \u0935\u0943\u0926\u094d\u0927\u093f \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948<\/li>\n\n\n\n<li><strong>\u0935\u093f\u0915\u0943\u0924\u093f\u092f\u093e\u0901<\/strong>: \u0905\u091a\u093e\u0928\u0915 \u0909\u091b\u093e\u0932 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0918\u091f\u0928\u093e\u0913\u0902 (\u092a\u094d\u0930\u092d\u093e\u0935, \u0938\u0902\u0926\u0942\u0937\u0923, \u0918\u091f\u0915 \u0935\u093f\u092b\u0932\u0924\u093e) \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0909\u0926\u093e\u0939\u0930\u0923 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0935\u094d\u092f\u093e\u0916\u094d\u092f\u093e:<\/strong><\/p>\n\n\n\n<p>\u092f\u0926\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 20,000 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092e\u0947\u0902 100 \u03bc\u03a9 \u0938\u0947 \u092c\u0922\u093c\u0915\u0930 150 \u03bc\u03a9 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u0924\u094b \u0930\u0948\u0916\u093f\u0915 \u0905\u0928\u0941\u092e\u093e\u0928 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0932\u0917\u092d\u0917 50,000 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092a\u0930 \u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e 250 \u03bc\u03a9 \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u091c\u093e\u090f\u0917\u0940\u2014\u0909\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u090f\u0901\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"creating-a-maintenance-schedule-template\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f \u092c\u0928\u093e\u0928\u093e<\/h3>\n\n\n\n<p><strong>\u0928\u092e\u0942\u0928\u093e \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u092a\u094d\u0930\u093e\u0930\u0942\u092a:<\/strong><\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0930\u093f\u0915\u0949\u0930\u094d\u0921   \u0909\u092a\u0915\u0930\u0923 \u0906\u0908\u0921\u0940: VC-101   \u0938\u094d\u0925\u093e\u0928: MCC-3, \u092c\u0947 5   \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e: XBRELE   \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c: 12 kV   \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f: 400 A   \u0906\u0935\u0947\u0926\u0928: \u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u0930 (\u092a\u0902\u0916\u093e \u092e\u094b\u091f\u0930)\n\n\u0926\u093f\u0928\u093e\u0902\u0915: _______ \u092a\u093f\u091b\u0932\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u092c\u093e\u0926 \u0938\u0902\u091a\u093e\u0932\u0928: _______ \u092a\u0930\u093f\u0935\u0947\u0936 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928: _______\u00b0C \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u03bc\u03a9): \u092b\u0947\u091c A: _______ (\u092c\u0947\u0938\u0932\u093e\u0907\u0928: 85 \u03bc\u03a9) \u092b\u0947\u091c B: _______ (\u092c\u0947\u0938\u0932\u093e\u0907\u0928: 82 \u03bc\u03a9) \u092b\u0947\u091c C: _______ (\u092c\u0947\u0938\u0932\u093e\u0907\u0928: 88 \u03bc\u03a9)\n\n\u091f\u093e\u0907\u092e\u093f\u0902\u0917: \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f: _______ \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 60-80 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f: _______ \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 25-35 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e: _______ \u092e\u093f\u092e\u0940 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 10 \u00b1 1 \u092e\u093f\u092e\u0940) \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923: [ ] \u0924\u0902\u0924\u094d\u0930 \u0938\u093e\u092b, \u091a\u093f\u0915\u0928\u093e\u0908\u092f\u0941\u0915\u094d\u0924\n  [ ] \u0915\u094b\u0908 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u093e \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u091c\u0902\u0917 \u0928\u0939\u0940\u0902 [ ] \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 [ ] \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938 \u0920\u0940\u0915 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 [ ] \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u094b\u0908 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0936\u094b\u0930 \u092f\u093e \u0915\u0902\u092a\u0928 \u0928\u0939\u0940\u0902 \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0940 \u0917\u0908: _____________________________________________ \u0905\u0917\u0932\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u093f\u0925\u093f: _________ (\u0926\u093f\u0928\u093e\u0902\u0915) \u092f\u093e _________ \u0938\u0902\u091a\u093e\u0932\u0928 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0915: __________________ \u0939\u0938\u094d\u0924\u093e\u0915\u094d\u0937\u0930: __________\n<\/code><\/pre>\n\n\n\n<p>\u0909\u092a\u0915\u0930\u0923 \u0915\u0947 \u092a\u0942\u0930\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0930\u0916\u0947\u0902\u2014\u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0947 \u0930\u0941\u091d\u093e\u0928 \u0910\u0938\u0947 \u092a\u0948\u091f\u0930\u094d\u0928 \u0909\u091c\u093e\u0917\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u090f\u0915\u0932 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0938\u094d\u092a\u0937\u094d\u091f \u0928\u0939\u0940\u0902 \u0939\u094b\u0924\u0947\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-problems-and-troubleshooting\">\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0914\u0930 \u0938\u092e\u093e\u0927\u093e\u0928<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0932\u0915\u094d\u0937\u0923<\/th><th>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/th><th>\u0928\u093f\u0926\u093e\u0928\u093e\u0924\u094d\u092e\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/th><th>\u0909\u092a\u091a\u093e\u0930<\/th><\/tr><\/thead><tbody><tr><td><strong>\u092c\u0902\u0926 \u0928\u0939\u0940\u0902 \u0939\u094b\u0917\u093e<\/strong><\/td><td>\u0928\u094d\u092f\u0942\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0915\u0949\u0907\u0932 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0905\u091f\u0915\u093e\u0935<\/td><td>\u0915\u094b\u0907\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u093e\u092a\u0947\u0902, \u092c\u093e\u0907\u0902\u0921\u093f\u0902\u0917 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u0915\u094b\u0907\u0932 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/td><td>\u0938\u0939\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0906\u092a\u0942\u0930\u094d\u0924\u093f, \u092e\u0941\u0915\u094d\u0924 \u0924\u0902\u0924\u094d\u0930, \u0915\u0949\u0907\u0932 \u092c\u0926\u0932\u0947\u0902\u0964<\/td><\/tr><tr><td><strong>\u0916\u0941\u0932 \u0928\u0939\u0940\u0902 \u0930\u0939\u093e<\/strong><\/td><td>\u0913\u092a\u0928\u093f\u0902\u0917 \u0915\u0949\u0907\u0932 \u0915\u0940 \u0916\u0930\u093e\u092c\u0940, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091c\u093e\u092e, \u0905\u091f\u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915<\/td><td>\u092f\u0926\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0939\u094b \u0924\u094b \u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0947\u0902, \u0916\u094b\u0932\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u0949\u0907\u0932 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902, \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964<\/td><td>\u0915\u094b\u0907\u0932 \u092c\u0926\u0932\u0947\u0902, \u092b\u094d\u0930\u0940 \u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u092c\u0926\u0932\u0947\u0902, \u092f\u0926\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u0935\u0947\u0932\u094d\u0921 \u0939\u094b \u0917\u090f \u0939\u094b\u0902 \u0924\u094b \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0926\u0932\u0947\u0902\u0964<\/td><\/tr><tr><td><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093e\u0924\u091a\u0940\u0924<\/strong><\/td><td>\u0905\u0902\u0921\u0930-\u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0926\u0942\u0937\u093f\u0924 \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0905\u0928\u0941\u0928\u093e\u0926<\/td><td>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0949\u0907\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/td><td>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092c\u0922\u093c\u093e\u090f\u0901, \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902, \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u091c\u094b\u0921\u093c\u0947\u0902<\/td><\/tr><tr><td><strong>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0924\u093e\u092a<\/strong><\/td><td>\u0909\u091a\u094d\u091a \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0905\u0927\u093f\u092d\u093e\u0930, \u0916\u0930\u093e\u092c \u0935\u0948\u0915\u094d\u092f\u0942\u092e<\/td><td>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0947\u0902, \u0932\u094b\u0921 \u0927\u093e\u0930\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/td><td>\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902\/\u092c\u0926\u0932\u0947\u0902, \u0932\u094b\u0921 \u091c\u093e\u0902\u091a\u0947\u0902, \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td><strong>\u0938\u094d\u092a\u0947\u0915 \u0938\u0947 \u092c\u093e\u0939\u0930 \u0938\u092e\u092f \u0938\u092e\u093e\u092a\u094d\u0924 \u0939\u094b\u0928\u093e<\/strong><\/td><td>\u0918\u093f\u0938\u093e \u0939\u0941\u0906 \u0932\u093f\u0902\u0915, \u0938\u0942\u0916\u093e \u0939\u0941\u0906 \u091a\u093f\u0915\u0928\u093e\u0908 \u092a\u0926\u093e\u0930\u094d\u0925, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0925\u0915\u093e\u0928<\/td><td>\u092f\u0902\u0924\u094d\u0930 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u0938\u092e\u092f \u092e\u093e\u092a\u0947\u0902, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964<\/td><td>\u092a\u0941\u0928\u0903 \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0930\u0947\u0902, \u0924\u0902\u0924\u094d\u0930 \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902, \u0918\u093f\u0938\u0947 \u0939\u0941\u090f \u092a\u0941\u0930\u094d\u091c\u0947 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree.webp\" alt=\"\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u0923\u092f \u0935\u0943\u0915\u094d\u0937 \u0915\u093e \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923, \u091c\u094b \u0932\u0915\u094d\u0937\u0923\u094b\u0902 (\u092c\u0902\u0926 \u0928\u0939\u0940\u0902 \u0939\u094b\u0928\u093e, \u0916\u0921\u093c\u0916\u0921\u093c\u093e\u0939\u091f, \u0917\u0930\u094d\u092e\u0940) \u0938\u0947 \u092e\u0942\u0932 \u0915\u093e\u0930\u0923\u094b\u0902 \u0914\u0930 \u0909\u092a\u093e\u092f\u094b\u0902 \u0924\u0915 \u0928\u093f\u0926\u093e\u0928 \u092a\u0925 \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948\u0964\" class=\"wp-image-2516\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u091a\u093f\u0924\u094d\u0930 4**: \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0928\u093f\u0930\u094d\u0923\u092f \u0935\u0943\u0915\u094d\u0937 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0928\u093f\u0926\u093e\u0928 \u092e\u0947\u0902 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0932\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c\/\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\/\u0924\u093e\u092a\u0940\u092f \u0928\u093f\u0926\u093e\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0909\u092a\u093e\u092f\u094b\u0902 \u0924\u0915 \u092a\u0939\u0941\u0902\u091a\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0938\u0902\u0930\u091a\u093f\u0924 \u0938\u092e\u0938\u094d\u092f\u093e-\u0938\u092e\u093e\u0927\u093e\u0928 \u092a\u0926\u094d\u0927\u0924\u093f \u0915\u0947 \u091c\u0930\u093f\u090f \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0915\u092e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"safety-precautions\">\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u093e\u0935\u0927\u093e\u0928\u093f\u092f\u093e\u0901<\/h2>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0947\u0902 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0916\u0924\u0930\u0947 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0915\u093e\u092e \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0905\u0932\u0917\u093e\u0935 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong>\u0938\u092d\u0940 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u0940 \u0905\u0928\u0941\u092a\u0938\u094d\u0925\u093f\u0924\u093f \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/li>\n\n\n\n<li><strong>\u0928\u093f\u0937\u094d\u0915\u093e\u0938\u0928 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930<\/strong>\u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0921\u094d\u092f\u0942\u091f\u0940 \u092e\u0947\u0902 \u0932\u0917\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u0947 \u092c\u093e\u0926 \u092e\u093f\u0928\u091f\u094b\u0902 \u0924\u0915 \u091a\u093e\u0930\u094d\u091c \u0938\u0902\u0917\u094d\u0930\u0939\u0940\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0932\u0949\u0915 \u0906\u0909\u091f\/\u091f\u0948\u0917 \u0906\u0909\u091f<\/strong>\u0915\u093e\u092e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u090a\u0930\u094d\u091c\u093e \u0938\u0915\u094d\u0930\u093f\u092f\u0923 \u0915\u094b \u0930\u094b\u0915\u0947\u0902<\/li>\n\n\n\n<li><strong>\u0906\u0930\u094d\u0915 \u092b\u094d\u0932\u0948\u0936 \u092a\u0940\u092a\u0940\u0908<\/strong>: \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0935\u093f\u0939\u0940\u0928 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092d\u0940, \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092f\u093e \u0938\u0902\u091a\u093f\u0924 \u090a\u0930\u094d\u091c\u093e \u0906\u0930\u094d\u0915 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>: \u0915\u0947\u0935\u0932 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u0940 \u0939\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0926\u0942\u0930\u0940 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902<\/li>\n\n\n\n<li><strong>\u092e\u0948\u0928\u0941\u0905\u0932 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0938\u0902\u0917\u094d\u0930\u0939\u093f\u0924 \u090a\u0930\u094d\u091c\u093e \u0938\u0947 \u0938\u093e\u0935\u0927\u093e\u0928 \u0930\u0939\u0947\u0902\u2014\u092f\u0939 \u0924\u0940\u0935\u094d\u0930 \u0914\u0930 \u091c\u094b\u0930\u0926\u093e\u0930 \u0917\u0924\u093f \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928 \u0938\u0915\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li><strong>\u0926\u0942\u0937\u0923<\/strong>\u092a\u0941\u0930\u093e\u0928\u0940 \u0917\u094d\u0930\u0940\u0938 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0927\u0942\u0932 \u092e\u0947\u0902 \u0916\u0924\u0930\u0928\u093e\u0915 \u092a\u0926\u093e\u0930\u094d\u0925 (\u0915\u0948\u0921\u092e\u093f\u092f\u092e, \u091a\u093e\u0902\u0926\u0940) \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u2014\u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0926\u0938\u094d\u0924\u093e\u0928\u0947 \u092a\u0939\u0928\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u092c\u093e\u0926:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0938\u0939\u0940 \u092a\u0941\u0928\u0903 \u0938\u0902\u092f\u094b\u091c\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902<\/strong>\u0938\u092d\u0940 \u092b\u093e\u0938\u094d\u091f\u0928\u0930 \u0915\u0938\u0915\u0930 \u091a\u0947\u0915 \u0915\u0930\u0947\u0902, \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0939\u094b\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>\u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0932\u094c\u091f\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u0908 \u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0932\u094b\u0921 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>&nbsp;\u092f\u0926\u093f \u0938\u0902\u092d\u0935 \u0939\u094b: \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p>\u092a\u0942\u0930\u094d\u0923 VCB \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u0947 \u0909\u091a\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f, \u0938\u0902\u0926\u0930\u094d\u092d\u00a0<a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\">\u090f\u0915\u094d\u0938\u092c\u0940\u0906\u0930\u0908\u090f\u0932\u0908 \u0915\u093e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/a> \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u092e\u0941\u0916\u094d\u092f \u092c\u093e\u0924\u0947\u0902<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u094b \u0909\u091a\u094d\u091a \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0906\u0935\u0943\u0924\u094d\u0924\u093f (5,000\u201350,000 \u0938\u0902\u091a\u093e\u0932\u0928\/\u0935\u0930\u094d\u0937, \u091c\u092c\u0915\u093f \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f 5\u201320) \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0915\u094d\u0930\u093f\u092f \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928 (100A+ \u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947) \u0938\u0902\u092a\u0930\u094d\u0915 \u0918\u093f\u0938\u093e\u0935 \u0915\u093e \u0938\u092c\u0938\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u0915\u0947\u0924\u0915 \u0939\u0948\u2014\u091c\u092c &gt;250 \u03bc\u03a9 \u092f\u093e 3\u00d7 \u0906\u0927\u093e\u0930\u092d\u0942\u0924 \u092e\u093e\u0928 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b, \u0924\u092c \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0942\u092b\u093c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092f\u093e \u0917\u0948\u092a \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0930\u094d\u0927\u0935\u093e\u0930\u094d\u0937\u093f\u0915) \u0915\u094d\u0937\u0940\u0923 \u0939\u094b \u091a\u0941\u0915\u0947 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u093e \u0939\u0948, \u0907\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u093f \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u093f\u0902\u0917 \u0915\u094d\u0937\u092e\u0924\u093e \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u090f\u0964<\/li>\n\n\n\n<li>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u092f\u093e\u0924\u094d\u0930\u093e (\u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u093e 90\u2013110% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f), \u0938\u092e\u092f-\u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0915\u093e \u00b110% \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f) \u0914\u0930 \u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u2014\u0930\u0941\u091d\u093e\u0928 \u0918\u093f\u0938\u093e\u0935 \u0915\u0947 \u092a\u0948\u091f\u0930\u094d\u0928 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0911\u092a\u0930\u0947\u0936\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 (\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 5,000\/10,000\/20,000 \u0911\u092a\u094d\u0938) \u0909\u091a\u094d\u091a-\u0921\u094d\u092f\u0942\u091f\u0940 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u092c\u0947\u0939\u0924\u0930 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0909\u092a\u0915\u0930\u0923 \u0915\u0947 \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0930\u0941\u091d\u093e\u0928 \u0921\u0947\u091f\u093e \u090f\u0915\u0932 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u092e\u0947\u0902 \u0905\u0926\u0943\u0936\u094d\u092f \u0915\u094d\u0937\u0930\u0923 \u092a\u0948\u091f\u0930\u094d\u0928 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0938\u092d\u0940 \u092e\u093e\u092a\u0947 \u0917\u090f \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930\u094b\u0902 \u0915\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0935\u093f\u092b\u0932 \u0939\u0941\u090f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092b\u0940\u0932\u094d\u0921 \u092e\u0947\u0902 \u092e\u0930\u092e\u094d\u092e\u0924 \u0928\u0939\u0940\u0902 \u0915\u093f\u090f \u091c\u093e \u0938\u0915\u0924\u0947\u2014\u0915\u0947\u0935\u0932 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0939\u0940 \u092a\u0942\u0930\u094d\u0923 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u093f\u0902\u0917 \u0915\u094d\u0937\u092e\u0924\u093e \u092c\u0939\u093e\u0932 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u0926\u0930\u094d\u092d:<\/strong>&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">\u0906\u0908\u0908\u0938\u0940 62271-106<\/a>&nbsp;\u2014 \u090f\u0938\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f IEC 62271-106 \u092e\u093e\u0928\u0915<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 1: \u092e\u0941\u091d\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u092e\u093e\u092a\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/strong><br>A: \u0909\u091a\u094d\u091a-\u0915\u0930\u094d\u0924\u0935\u094d\u092f \u0935\u093e\u0932\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 (\u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u093f\u0902\u0917, \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917) \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 5,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u092f\u093e \u0905\u0930\u094d\u0927-\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0942\u092a \u0938\u0947, \u091c\u094b \u092d\u0940 \u092a\u0939\u0932\u0947 \u0939\u094b, \u092e\u093e\u092a \u0932\u0947\u0902\u0964 \u0915\u092e-\u0915\u0930\u094d\u0924\u0935\u094d\u092f \u0935\u093e\u0932\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 (1,000 \u0938\u0947 \u0915\u092e \u0938\u0902\u091a\u093e\u0932\u0928\/\u0935\u0930\u094d\u0937) \u0915\u0947 \u0932\u093f\u090f \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092e\u093e\u092a \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0939\u0948\u0964 \u0928\u090f \u0939\u094b\u0928\u0947 \u092a\u0930 \u0939\u092e\u0947\u0936\u093e \u0906\u0927\u093e\u0930 \u0930\u0947\u0916\u093e \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0930\u0941\u091d\u093e\u0928\u094b\u0902 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 2: \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0914\u0930 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u0915\u094d\u092f\u093e \u0905\u0902\u0924\u0930 \u0939\u0948?<\/strong><br>A: \u0924\u0915\u0928\u0940\u0915 \u0938\u092e\u093e\u0928 \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092e\u093e\u0928\u0926\u0902\u0921 \u092d\u093f\u0928\u094d\u0928 \u0939\u0948\u0902\u2014\u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0907\u0938\u0932\u093f\u090f \u0938\u0902\u092a\u0930\u094d\u0915 \u0924\u0924\u094d\u0935 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947 \u0918\u093f\u0938\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0924\u0924\u094d\u0935 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0947 \u092a\u0939\u0932\u0947 10,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0915 \u091f\u093f\u0915 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902; \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0924\u0924\u094d\u0935 \u092a\u094d\u0930\u0924\u093f \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u092e \u0927\u093e\u0930\u093e \u0939\u094b\u0928\u0947 \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926 \u0905\u0915\u094d\u0938\u0930 30,000\u201350,000 \u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930 \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 3: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u092e\u093e\u0928\u0915 \u092e\u0932\u094d\u091f\u0940\u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/strong><br>A: \u0928\u0939\u0940\u0902\u2014\u092e\u0932\u094d\u091f\u0940\u092e\u0940\u091f\u0930 \u092e\u093f\u0932\u0940\u090f\u092e\u094d\u092a\u093f\u092f\u0930-\u0938\u094d\u0924\u0930\u0940\u092f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u092e\u094c\u091c\u0942\u0926 \u0938\u0924\u0939\u0940 \u092b\u093f\u0932\u094d\u092e\u094b\u0902 \u0915\u094b \u092d\u0947\u0926 \u0928\u0939\u0940\u0902 \u092a\u093e\u0924\u0940\u0902, \u091c\u093f\u0938\u0938\u0947 \u0917\u0932\u0924 \u0930\u0942\u092a \u0938\u0947 \u0909\u091a\u094d\u091a \u0930\u0940\u0921\u093f\u0902\u0917 \u092e\u093f\u0932\u0924\u0940 \u0939\u0948\u0964 \u0938\u0924\u0939\u0940 \u0911\u0915\u094d\u0938\u093e\u0907\u0921 \u092a\u0930\u0924\u094b\u0902 \u0915\u094b \u092d\u0947\u0926\u0928\u0947 \u0914\u0930 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0927\u093e\u0924\u0941-\u0938\u0947-\u0927\u093e\u0924\u0941 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f 100A+ \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e \u0935\u093e\u0932\u0947 \u0938\u092e\u0930\u094d\u092a\u093f\u0924 \u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q4: \u0905\u0917\u0930 \u092e\u0947\u0930\u0947 \u092a\u093e\u0938 \u0939\u093e\u0908-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923 \u0928\u0939\u0940\u0902 \u0939\u0948, \u0924\u094b \u092e\u0941\u091d\u0947 \u0915\u0948\u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u0947\u0917\u093e \u0915\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092b\u0947\u0932 \u0939\u094b \u0917\u092f\u093e \u0939\u0948?<\/strong><br>A: \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 1,000V DC \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u2014\u0905\u091a\u094d\u091b\u0940 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092e\u0947\u0902 &gt;100 M\u03a9 \u0926\u093f\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964  \u0907\u0938\u0915\u0947 \u0905\u0932\u093e\u0935\u093e \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902: \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u093e (\u0925\u0930\u094d\u092e\u0932 \u0907\u092e\u0947\u091c\u093f\u0902\u0917), \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u0940 \u092f\u093e\u0924\u094d\u0930\u093e \u092e\u0947\u0902 \u0915\u092e\u0940 (&lt;\u0930\u0947\u091f\u0947\u0921 \u0915\u093e 80%), \u092f\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0916\u093f\u0921\u093c\u0915\u093f\u092f\u094b\u0902 \u0938\u0947 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0906\u0930\u094d\u0915 \u092b\u094d\u0932\u0948\u0936 \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u093e\u0964 \u0907\u0928\u092e\u0947\u0902 \u0938\u0947 \u0915\u094b\u0908 \u092d\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0926\u0930\u094d\u0936\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q5: \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092e\u0947\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0916\u094b \u091c\u093e\u0928\u0947 \u0915\u093e \u0915\u094d\u092f\u093e \u0915\u093e\u0930\u0923 \u0939\u0948?<\/strong><br>A: \u0938\u093f\u0930\u0947\u092e\u093f\u0915-\u0927\u093e\u0924\u0941 \u0938\u0940\u0932 (\u0939\u0940\u0932\u093f\u092f\u092e, \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u091c\u0928) \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0917\u0948\u0938 \u0905\u0923\u0941\u0913\u0902 \u0915\u093e \u0915\u094d\u0930\u092e\u093f\u0915 \u092a\u094d\u0930\u0938\u093e\u0930, \u0925\u0930\u094d\u092e\u0932 \u0938\u093e\u0907\u0915\u094d\u0932\u093f\u0902\u0917 \u0938\u0947 \u0938\u0942\u0915\u094d\u0937\u094d\u092e \u0926\u0930\u093e\u0930\u0947\u0902, \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923 \u0938\u0947 \u0906\u0902\u0924\u0930\u093f\u0915 \u0917\u0948\u0938 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 15\u201325 \u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u092c\u093f\u0917\u0921\u093c \u091c\u093e\u0924\u093e \u0939\u0948, \u0939\u093e\u0932\u093e\u0902\u0915\u093f \u0917\u0902\u092d\u0940\u0930 \u0909\u092a\u092f\u094b\u0917 \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0937 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u094b \u0924\u0947\u091c \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q6: \u0915\u094d\u092f\u093e \u092e\u0941\u091d\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092e\u0947\u0902 \u091a\u093f\u0915\u0928\u093e\u0908 \u0932\u0917\u093e\u0928\u0940 \u091a\u093e\u0939\u093f\u090f?<\/strong><br>\u0915\u092d\u0940 \u0928\u0939\u0940\u0902\u2014\u0915\u093e\u0902\u091f\u0948\u0915\u094d\u091f\u094d\u0938 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0907\u0928\u094d\u0939\u0947\u0902 \u0915\u092d\u0940 \u092d\u0940 \u091a\u093f\u0915\u0928\u093e\u0908 \u0928\u0939\u0940\u0902 \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0947\u0935\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u0947 \u092c\u0947\u092f\u0930\u093f\u0902\u0917\u094d\u0938, \u0932\u093f\u0902\u0915ages \u0914\u0930 \u092a\u093f\u0935\u091f \u092a\u0949\u0907\u0902\u091f\u094d\u0938 \u0915\u094b \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0930\u0947\u0902 \u091c\u094b \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0906\u0935\u0930\u0923 \u0915\u0947 \u092c\u093e\u0939\u0930 \u0939\u094b\u0902\u0964 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 -40 \u0938\u0947 +125\u00b0C \u0924\u0915 \u0930\u0947\u091f\u0947\u0921 \u0932\u093f\u0925\u093f\u092f\u092e \u0917\u094d\u0930\u0940\u0938)\u0964.<\/p>\n\n\n\n<p><strong>Q7: \u092e\u0948\u0902 \u0915\u0948\u0938\u0947 \u0905\u0928\u0941\u092e\u093e\u0928 \u0932\u0917\u093e \u0938\u0915\u0924\u093e \u0939\u0942\u0901 \u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f \u0932\u0947\u0902\u0938 \u0915\u092c \u092c\u0926\u0932\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948?<\/strong><br>A: \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0947\u0902: \u092f\u0926\u093f 20,000 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092e\u0947\u0902 100 \u03bc\u03a9 \u0938\u0947 180 \u03bc\u03a9 \u0924\u0915 \u0930\u0948\u0916\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092c\u0922\u093c\u0924\u093e \u0939\u0948, \u0924\u094b ~50,000 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092a\u0930 250 \u03bc\u03a9 \u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u092e\u093e\u0928 \u0932\u0917\u093e\u090f\u0901\u2014\u0909\u0938\u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u090f\u0901\u0964 \u0905\u091a\u093e\u0928\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u0947\u0902 \u0909\u091b\u093e\u0932 (&gt;20% \u0905\u0902\u0924\u0930\u093e\u0932\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a) \u0924\u0924\u094d\u0915\u093e\u0932 \u091c\u093e\u0901\u091a \u0914\u0930 \u0938\u0902\u092d\u0935\u0924\u0903 \u0938\u092e\u092f \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u092a\u0920\u0928 \u0914\u0930 \u091a\u092f\u0928 \u0938\u0902\u0938\u093e\u0927\u0928<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0938\u0940\u0915\u0947\u091c\u0940 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930<\/a> \u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u091c\u093e\u0901\u091a\u0947\u0902, \u0938\u0940\u092e\u093e\u090f\u0901, \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0928\u094b\u091f\u094d\u0938<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Medium-voltage vacuum contactors operate 10,000\u2013100,000 mechanical cycles over their service life. Unlike circuit breakers that interrupt fault currents occasionally, contactors switch load currents repeatedly\u2014often multiple times daily in motor control, capacitor switching, and frequent start-stop applications. This repetitive duty creates wear patterns maintenance teams must detect before they cause failures. Contact erosion from repeated arcing, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2512,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-2511","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2511","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2511"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2511\/revisions"}],"predecessor-version":[{"id":3619,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2511\/revisions\/3619"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2512"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2511"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2511"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2511"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}