{"id":2537,"date":"2026-01-10T07:15:50","date_gmt":"2026-01-10T07:15:50","guid":{"rendered":"https:\/\/xbrele.com\/?p=2537"},"modified":"2026-04-07T13:16:04","modified_gmt":"2026-04-07T13:16:04","slug":"vcb-maintenance-checklist","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/vcb-maintenance-checklist\/","title":{"rendered":"\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f: \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915\/\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0915\u094d\u092f\u093e \u0915\u0930\u0947\u0902 (\u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f)"},"content":{"rendered":"\ufeff\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u0947\u092f \u0924\u0930\u0940\u0915\u094b\u0902 \u0938\u0947 \u0935\u093f\u092b\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935\u091f \u0938\u0947 \u0938\u092e\u092f \u0935\u093f\u091a\u0932\u0928, \u0928\u092e\u0940 \u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u093e \u0915\u094d\u0937\u0930\u0923\u2014\u092f\u0947 \u0915\u094d\u0937\u0930\u0923 \u092e\u094b\u0921 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0947 \u092e\u0939\u0940\u0928\u094b\u0902 \u092a\u0939\u0932\u0947 \u0939\u0940 \u092e\u093e\u092a\u0928\u0940\u092f \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0938\u094d\u0935\u092f\u0902 \u0915\u094b \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0938\u093e\u0932\u093e\u0928\u093e \u0939\u091c\u093e\u0930\u094b\u0902 \u092c\u093e\u0930 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0935\u093f\u092a\u0930\u0940\u0924, VCB \u0915\u092d\u0940-\u0915\u092d\u093e\u0930 \u0939\u0940 \u092b\u0949\u0932\u094d\u091f\u094d\u0938 \u0915\u094b \u0907\u0902\u091f\u0930\u092a\u094d\u091f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u091c\u092c \u092d\u0940 \u0909\u0928\u094d\u0939\u0947\u0902 \u092c\u0941\u0932\u093e\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948, \u0909\u0928\u094d\u0939\u0947\u0902 \u0924\u094d\u0930\u0941\u091f\u093f\u0939\u0940\u0928 \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u090f\u0915 \u092c\u093e\u0930 \u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u094d\u0932\u093f\u092f\u0930 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0905\u0938\u092b\u0932 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928, \u0932\u0902\u092c\u0940 \u0921\u093e\u0909\u0928\u091f\u093e\u0907\u092e \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0918\u091f\u0928\u093e\u090f\u0902 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 50 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 \u092e\u0947\u0902 25 kA \u0915\u093e \u092b\u0949\u0932\u094d\u091f \u0915\u094d\u0932\u093f\u092f\u0930 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 VCB \u0914\u0930 \u091c\u094b \u0910\u0938\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0935\u093f\u092b\u0932 \u0930\u0939\u0924\u093e \u0939\u0948, \u0909\u0928\u0915\u0947 \u092c\u0940\u091a \u0915\u093e \u0905\u0902\u0924\u0930 \u0926\u0938\u093f\u092f\u094b\u0902 \u092f\u093e \u0938\u0948\u0915\u0921\u093c\u094b\u0902 \u0939\u091c\u093e\u0930\u094b\u0902 \u0921\u0949\u0932\u0930 \u0915\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0905\u0935\u0938\u094d\u0925\u093e \u092e\u0947\u0902 \u0939\u0940 \u092a\u0915\u0921\u093c \u0932\u0947\u0924\u093e \u0939\u0948\u0964 \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u094b \u0906\u0930\u094d\u0915 \u0915\u094d\u0937\u0924\u093f \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092a\u0939\u091a\u093e\u0928 \u0932\u0947\u0924\u093e \u0939\u0948\u0964 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 15% \u0927\u0940\u092e\u0940 \u0916\u0941\u0932\u0928\u0947 \u0915\u0940 \u0917\u0924\u093f \u0915\u094b \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0905\u092d\u0940 \u0924\u0915 \u0935\u093f\u092b\u0932\u0924\u093e \u0928\u0939\u0940\u0902, \u0932\u0947\u0915\u093f\u0928 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u0938\u0940\u092e\u093e \u0915\u0940 \u0913\u0930 \u092c\u0922\u093c \u0930\u0939\u093e \u0939\u0948\u0964 \u0938\u0902\u0930\u091a\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0928\u093f\u092f\u092e\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0930\u0941\u0915\u093e\u0935\u091f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928\u094b\u0902 \u092e\u0947\u0902 \u092c\u0926\u0932 \u0926\u0947\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p>\u092f\u0939 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0914\u0930 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e\u0930\u094d\u092f, \u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092e\u093e\u0928\u0926\u0902\u0921 \u0914\u0930 \u092b\u0940\u0932\u094d\u0921 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f\u094d\u0938 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/a>&nbsp;12\u201340.5 kV \u0930\u0947\u091f\u0947\u0921 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940, \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0914\u0930 \u0935\u093e\u0923\u093f\u091c\u094d\u092f\u093f\u0915 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e\u0964.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f: \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u092c\u0928\u093e\u092e \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0917\u093e\u0907\u0921 (\u092b\u0940\u0932\u094d\u0921 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f \u0936\u093e\u092e\u093f\u0932)\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/78lbXrzw85U?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-vcb-maintenance-differs-from-contactor-maintenance\">VCB \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0938\u0947 \u0915\u094d\u092f\u094b\u0902 \u092d\u093f\u0928\u094d\u0928 \u0939\u0948<\/h2>\n\n\n\n<p>\u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0926\u094b\u0928\u094b\u0902 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0909\u0928\u0915\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u092e\u0947\u0902 \u0915\u093e\u092b\u0940 \u092d\u093f\u0928\u094d\u0928\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u093e\u0907\u0915\u093f\u0932 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th><th>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930<\/th><th>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930<\/th><\/tr><\/thead><tbody><tr><td><strong>\u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u094d\u092f<\/strong><\/td><td>\u0924\u094d\u0930\u0941\u091f\u093f \u0930\u0941\u0915\u093e\u0935\u091f<\/td><td>\u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917<\/td><\/tr><tr><td><strong>\u0938\u0902\u091a\u093e\u0932\u0928\/\u0935\u0930\u094d\u0937<\/strong><\/td><td>5\u201320 (\u0926\u0941\u0930\u094d\u0932\u092d \u0926\u094b\u0937 \u0928\u093f\u0935\u093e\u0930\u0923)<\/td><td>5,000\u201350,000 (\u092c\u093e\u0930-\u092c\u093e\u0930 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917)<\/td><\/tr><tr><td><strong>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u092c\u093e\u0927\u093f\u0924<\/strong><\/td><td>10\u201340\u00d7 \u0930\u0947\u091f\u0947\u0921 (\u0936\u0949\u0930\u094d\u091f \u0938\u0930\u094d\u0915\u093f\u091f)<\/td><td>1\u20138\u00d7 \u0930\u0947\u091f\u0947\u0921 (\u0907\u0928\u0930\u0936\/\u0928\u0949\u0930\u094d\u092e\u0932)<\/td><\/tr><tr><td><strong>\u092a\u094d\u0930\u0924\u093f \u0938\u0902\u091a\u093e\u0932\u0928 \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e<\/strong><\/td><td>\u092c\u0939\u0941\u0924 \u0909\u091a\u094d\u091a (kA-\u0938\u094d\u0924\u0930 \u0915\u0940 \u0916\u0930\u093e\u092c\u0940)<\/td><td>\u092e\u0927\u094d\u092f\u092e (\u0932\u094b\u0921-\u0938\u094d\u0924\u0930 \u0915\u0947 \u0927\u093e\u0930\u093e\u090f\u0901)<\/td><\/tr><tr><td><strong>\u0938\u0902\u091a\u092f\u0940 \u091a\u093e\u092a \u090a\u0930\u094d\u091c\u093e<\/strong><\/td><td>\u092e\u0927\u094d\u092f\u092e (\u0915\u0941\u091b \u0939\u0940 \u0911\u092a\u0930\u0947\u0936\u0928 \u00d7 \u0909\u091a\u094d\u091a \u090a\u0930\u094d\u091c\u093e)<\/td><td>\u0909\u091a\u094d\u091a (\u0915\u0908 \u0938\u0902\u091a\u093e\u0932\u0928 \u00d7 \u092e\u0927\u094d\u092f\u092e \u090a\u0930\u094d\u091c\u093e)<\/td><\/tr><tr><td><strong>\u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u092a\u0930\u093f\u0923\u093e\u092e<\/strong><\/td><td>\u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 (\u0909\u092a\u0915\u0930\u0923 \u0915\u093e \u0935\u093f\u0928\u093e\u0936, \u0938\u0941\u0930\u0915\u094d\u0937\u093e)<\/td><td>\u092e\u0927\u094d\u092f\u092e (\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u092e\u0947\u0902 \u0930\u0941\u0915\u093e\u0935\u091f)<\/td><\/tr><tr><td><strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e<\/strong><\/td><td>\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0916\u0902\u0921\u0924\u093e<\/td><td>\u0938\u0902\u091a\u093e\u0932\u0928 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u0930 \u091c\u094b\u0930&nbsp;<strong>\u0924\u0948\u092f\u093e\u0930\u0940<\/strong>\u2014\u092f\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u093e \u0915\u093f \u0926\u0941\u0930\u094d\u0932\u092d \u0926\u094b\u0937 \u0918\u091f\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092c\u094d\u0930\u0947\u0915\u0930 \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0947\u0917\u093e\u0964 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u0930 \u091c\u094b\u0930&nbsp;<strong>\u0927\u0948\u0930\u094d\u092f<\/strong>\u2014\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a \u0915\u0930\u0928\u0947 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u0902\u091a\u092f\u0940 \u0918\u093f\u0938\u093e\u0935\u091f \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0928\u093e\u0964.<\/p>\n\n\n\n<p>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u092d\u0940 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vcb-lubrication-overhaul-guide\/\">\u0935\u0940\u0938\u0940\u092c\u0940 \u0938\u094d\u0928\u0947\u0939\u0928 \u0914\u0930 \u0913\u0935\u0930\u0939\u0949\u0932 \u0930\u0923\u0928\u0940\u0924\u093f<\/a>&nbsp;\u0938\u093e\u0925 \u0939\u0940 \u0921\u093f\u091c\u093c\u093e\u0907\u0928, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0935\u0930\u094d\u0917 \u0914\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0935\u093e\u0924\u093e\u0935\u0930\u0923\u0964 \u0927\u0942\u0932 \u092d\u0930\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0907\u0928\u0921\u094b\u0930 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u094b \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0938\u092b\u093e\u0908 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948, \u091c\u092c\u0915\u093f \u092c\u093e\u0939\u0930\u0940 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u092e\u094c\u0938\u092e \u0915\u0947 \u092a\u094d\u0930\u092d\u093e\u0935 \u0914\u0930 \u0924\u093e\u092a\u092e\u093e\u0928 \u091a\u0915\u094d\u0930\u0923 \u0915\u0940 \u091a\u0941\u0928\u094c\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p>\u0926\u094b\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928 \u0914\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u091c\u093e\u0902\u091a \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 VCBs \u092e\u0947\u0902 \u0938\u092e\u092f\/\u092f\u093e\u0924\u094d\u0930\u093e \u092a\u0930 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0927\u094d\u092f\u093e\u0928 \u0926\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948 (\u0905\u0935\u0930\u094b\u0927 \u0915\u094d\u0937\u092e\u0924\u093e \u0916\u0941\u0932\u0928\u0947 \u0915\u0940 \u0917\u0924\u093f \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948) \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f (\u0930\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u094b \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f)\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-interval-framework\">\u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u0930\u0942\u092a\u0930\u0947\u0916\u093e<\/h2>\n\n\n\n<p>\u0935\u094d\u092f\u093e\u092a\u0915 \u0915\u0935\u0930\u0947\u091c \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924, \u0938\u0902\u091a\u093e\u0932\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0914\u0930 \u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930\u094d\u0938 \u0915\u094b \u0938\u0902\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"quarterly-maintenance-every-3-months\">\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 (\u0939\u0930 3 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902)<\/h3>\n\n\n\n<p><strong>\u0926\u093e\u092f\u0930\u093e<\/strong>: \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923, \u092c\u0941\u0928\u093f\u092f\u093e\u0926\u0940 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u091c\u093e\u0901\u091a\u0947\u0902<br><strong>\u0905\u0935\u0927\u093f<\/strong>: \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0932\u093f\u090f 30\u201360 \u092e\u093f\u0928\u091f<br><strong>\u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948<\/strong>\u0938\u0941\u0935\u093f\u0927\u093e \u0926\u094c\u0930\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u092a\u094d\u0930\u092d\u093e\u0935<\/p>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u092f<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 (\u092c\u093e\u0939\u0930\u0940 \u0938\u094d\u0925\u093f\u0924\u093f, \u0938\u094d\u0935\u091a\u094d\u091b\u0924\u093e)<\/li>\n\n\n\n<li>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u091c\u093e\u0901\u091a (\u092e\u0948\u0928\u0941\u0905\u0932 \u092f\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091f\u094d\u0930\u093f\u092a\/\u0915\u094d\u0932\u094b\u091c\u093c \u092a\u0930\u0940\u0915\u094d\u0937\u0923)<\/li>\n\n\n\n<li>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 (\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930, \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u093e\u0930\u094d\u092f)<\/li>\n\n\n\n<li>\u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 (\u092a\u0939\u0941\u0902\u091a \u092f\u094b\u0917\u094d\u092f \u092c\u094b\u0932\u094d\u091f\u0947\u0921 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u092a\u0930 \u091f\u0949\u0930\u094d\u0915 \u091c\u093e\u0902\u091a)<\/li>\n\n\n\n<li>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0906\u0915\u0932\u0928 (\u0924\u093e\u092a\u092e\u093e\u0928, \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e, \u092a\u094d\u0930\u0926\u0942\u0937\u0923 \u0938\u094d\u0924\u0930)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"annual-maintenance-every-12-months\">\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 (\u0939\u0930 12 \u092e\u0939\u0940\u0928\u0947 \u092e\u0947\u0902)<\/h3>\n\n\n\n<p><strong>\u0926\u093e\u092f\u0930\u093e<\/strong>: \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<br><strong>\u0905\u0935\u0927\u093f<\/strong>: \u092a\u094d\u0930\u0924\u093f \u092c\u094d\u0930\u0947\u0915\u0930 2\u20134 \u0918\u0902\u091f\u0947<br><strong>\u0906\u0935\u0936\u094d\u092f\u0915<\/strong>\u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923, \u0935\u093f\u0936\u0947\u0937 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923, \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u0940<\/p>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u092f<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928 (\u0938\u092d\u0940 \u0927\u094d\u0930\u0941\u0935\u094b\u0902)<\/li>\n\n\n\n<li>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925\u094b\u0902, \u092b\u094d\u0930\u0947\u092e)<\/li>\n\n\n\n<li>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0916\u094b\u0932\u0928\u0947\/\u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0917\u0924\u093f, \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e)<\/li>\n\n\n\n<li>\u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 (\u0938\u094d\u0928\u0947\u0939\u0928, \u0918\u093f\u0938\u093e\u0935, \u0938\u0902\u0930\u0947\u0916\u0923)<\/li>\n\n\n\n<li>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u091c\u093e\u0901\u091a (\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u092f\u093e \u0935\u0948\u0915\u0932\u094d\u092a\u093f\u0915 \u0935\u093f\u0927\u093f\u092f\u093e\u0901)<\/li>\n\n\n\n<li>\u0938\u0939\u093e\u092f\u0915 \u0914\u0930 \u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/li>\n\n\n\n<li>\u0938\u0902\u0930\u0915\u094d\u0937\u0923 \u0930\u093f\u0932\u0947 \u0938\u092e\u0928\u094d\u0935\u092f \u0938\u092e\u0940\u0915\u094d\u0937\u093e<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"biennialextended-maintenance-every-2\u20135-years\">\u0926\u094d\u0935\u093f\u0935\u093e\u0930\u094d\u0937\u093f\u0915\/\u0935\u093f\u0938\u094d\u0924\u093e\u0930\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 (\u0939\u0930 2\u20135 \u0935\u0930\u094d\u0937)<\/h3>\n\n\n\n<p><strong>\u0926\u093e\u092f\u0930\u093e<\/strong>\u0935\u094d\u092f\u093e\u092a\u0915 \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928, \u0905\u0915\u094d\u0938\u0930 \u092c\u0921\u093c\u0947 \u0935\u094d\u092f\u0935\u0927\u093e\u0928\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u092e\u0947\u0932 \u0916\u093e\u0924\u093e \u0939\u0948<br><strong>\u0905\u0935\u0927\u093f<\/strong>: \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0932\u093f\u090f \u092a\u0942\u0930\u093e \u0926\u093f\u0928 (\u092a\u0948\u0928\u0932 \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u0915\u0947 \u0938\u093e\u0925)<\/p>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u092f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u092d\u0940 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u0947 \u0905\u0932\u093e\u0935\u093e:<\/li>\n\n\n\n<li>\u0906\u0902\u0924\u0930\u093f\u0915 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 (\u092f\u0926\u093f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u092a\u0939\u0941\u0901\u091a \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948)<\/li>\n\n\n\n<li>\u0932\u094b\u0921 \u0915\u0947 \u0924\u0939\u0924 \u0925\u0930\u094d\u092e\u0932 \u0907\u092e\u0947\u091c\u093f\u0902\u0917 (\u092f\u0926\u093f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u090a\u0930\u094d\u091c\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0928\u093e \u0938\u0902\u092d\u0935 \u0939\u094b)<\/li>\n\n\n\n<li>\u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0909\u0928\u094d\u0928\u0924 \u0928\u093f\u0926\u093e\u0928)<\/li>\n\n\n\n<li>\u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u093e \u092a\u0942\u0930\u094d\u0923 \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923 (\u0935\u093f\u0916\u0902\u0921\u0928, \u0938\u092b\u093e\u0908, \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u0940 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928)<\/li>\n\n\n\n<li>\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u091f\u094d\u0930\u093f\u092a \u092f\u0942\u0928\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092b\u0930\u094d\u092e\u0935\u0947\u092f\u0930 \u0905\u092a\u0921\u0947\u091f<\/li>\n\n\n\n<li>\u092c\u0947\u0921\u093c\u0947 \u092e\u0947\u0902 \u0938\u092e\u093e\u0928 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e (\u092c\u0947\u0921\u093c\u0947 \u0915\u0940 \u0938\u0947\u0939\u0924 \u0915\u093e \u0930\u0941\u091d\u093e\u0928)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operation-based-triggers\">\u0911\u092a\u0930\u0947\u0936\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930<\/h3>\n\n\n\n<p>\u0938\u092e\u092f \u0915\u0940 \u092a\u0930\u0935\u093e\u0939 \u0915\u093f\u090f \u092c\u093f\u0928\u093e, \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0947 \u092c\u093e\u0926 \u092a\u0942\u0930\u094d\u0923 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 2,000 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>&nbsp;\u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 (\u091c\u0928\u0930\u0947\u091f\u0930 \u092c\u094d\u0930\u0947\u0915\u0930, \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0938\u094d\u0915\u0940\u092e) \u092e\u0947\u0902 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<\/li>\n\n\n\n<li><strong>\u0915\u093f\u0938\u0940 \u092d\u0940 \u0926\u094b\u0937 \u0930\u0941\u0915\u093e\u0935\u091f \u0915\u0947 \u092c\u093e\u0926<\/strong>&nbsp;\u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u0915\u093e 50%<\/li>\n\n\n\n<li><strong>\u0915\u093f\u0938\u0940 \u092d\u0940 \u0905\u0938\u092b\u0932 \u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u0947 \u092c\u093e\u0926<\/strong>&nbsp;(\u091f\u094d\u0930\u093f\u092a \u0928 \u0939\u094b\u0928\u093e, \u092c\u0902\u0926 \u0928 \u0939\u094b\u0928\u093e, \u0905\u092a\u0942\u0930\u094d\u0923 \u092f\u093e\u0924\u094d\u0930\u093e)<\/li>\n<\/ul>\n\n\n\n<p>\u091f\u094d\u0930\u0948\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u093e\u0909\u0902\u091f\u0930 (\u092f\u0926\u093f \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0939\u094b)<\/li>\n\n\n\n<li>\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u091f\u094d\u0930\u093f\u092a \u092f\u0942\u0928\u093f\u091f \u0918\u091f\u0928\u093e \u0932\u0949\u0917<\/li>\n\n\n\n<li>SCADA \u0938\u0902\u091a\u093e\u0932\u0928 \u0905\u092d\u093f\u0932\u0947\u0916<\/li>\n\n\n\n<li>\u092e\u0948\u0928\u0941\u0905\u0932 \u0932\u0949\u0917 \u0936\u0940\u091f\u094d\u0938 (\u0915\u093e\u0909\u0902\u091f\u0930 \u0915\u0947 \u092c\u093f\u0928\u093e \u092a\u0941\u0930\u093e\u0928\u0947 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"condition-based-triggers\">\u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930<\/h3>\n\n\n\n<p>\u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0924\u0924\u094d\u0915\u093e\u0932 \u092c\u093f\u0928\u093e \u092a\u0942\u0930\u094d\u0935 \u0928\u093f\u092f\u094b\u091c\u0928 \u0915\u0947 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0936\u094b\u0930 (\u0918\u093f\u0938\u0928\u0947, \u091f\u0915\u0930\u093e\u0928\u0947 \u0915\u0940 \u0906\u0935\u093e\u091c\u093c\u0947\u0902)<\/li>\n\n\n\n<li>\u0935\u093f\u0938\u094d\u0924\u093e\u0930\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u092e\u092f \u0926\u0947\u0916\u093e \u0917\u092f\u093e<\/li>\n\n\n\n<li>\u0926\u0943\u0936\u094d\u092f\u092e\u093e\u0928 \u0906\u0930\u094d\u0915\u093f\u0902\u0917 \u092f\u093e \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930<\/li>\n\n\n\n<li>\u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u092f\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0940 \u0916\u0930\u093e\u092c\u0940<\/li>\n\n\n\n<li>\u0924\u093e\u092a\u092e\u093e\u0928 \u092e\u0947\u0902 \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u093e \u092a\u0924\u093e \u091a\u0932\u093e (\u0925\u0930\u094d\u092e\u0932 \u0907\u092e\u0947\u091c\u093f\u0902\u0917 \u0926\u094c\u0930)<\/li>\n\n\n\n<li>\u0938\u0902\u0930\u0915\u094d\u0937\u0923\u093e\u0924\u094d\u092e\u0915 \u0930\u093f\u0932\u0947 \u0915\u093e \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u091f\u094d\u0930\u093f\u092a (\u0935\u0940\u0938\u0940\u092c\u0940 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0921\u094d\u0930\u093f\u092b\u094d\u091f \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948)<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix.webp\" alt=\"\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924, \u0938\u0902\u091a\u093e\u0932\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0914\u0930 \u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930\u094d\u0938 \u0915\u0947 \u0935\u093f\u0930\u0941\u0926\u094d\u0927 \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915, \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0914\u0930 \u0926\u094d\u0935\u093f\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u094b \u092e\u0948\u092a \u0915\u0930\u0924\u0947 \u0939\u0941\u090f \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u0928\u093f\u0930\u094d\u0923\u092f \u092e\u0948\u091f\u094d\u0930\u093f\u0915\u094d\u0938\" class=\"wp-image-2539\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-maintenance-interval-decision-matrix-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u091a\u093f\u0924\u094d\u0930 1**: \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u0922\u093e\u0902\u091a\u093e \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 (\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915\/\u0935\u093e\u0930\u094d\u0937\u093f\u0915\/\u0926\u094d\u0935\u093f\u0935\u093e\u0930\u094d\u0937\u093f\u0915), \u0938\u0902\u091a\u093e\u0932\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 (\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 2,000 \u0938\u0902\u091a\u093e\u0932\u0928, \u0926\u094b\u0937\u094b\u092a\u0930\u093e\u0902\u0924), \u0914\u0930 \u0938\u094d\u0925\u093f\u0924\u093f-\u0906\u0927\u093e\u0930\u093f\u0924 \u091f\u094d\u0930\u093f\u0917\u0930 (\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0936\u094b\u0930, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0921\u094d\u0930\u093f\u092b\u094d\u091f) \u0915\u094b \u0938\u0902\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948 \u0924\u093e\u0915\u093f \u0935\u094d\u092f\u093e\u092a\u0915 VCB \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0939\u094b \u0938\u0915\u0947\u0964.\n<br><\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quarterly-maintenance-detailed-procedure\">\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935: \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/h2>\n\n\n\n<p>\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u091c\u093e\u0902\u091a\u0947\u0902 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0947 \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u0940 \u0909\u0928\u094d\u0939\u0947\u0902 \u092a\u0915\u0921\u093c \u0932\u0947\u0924\u0940 \u0939\u0948\u0902, \u0907\u0938\u0938\u0947 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0928\u0939\u0940\u0902 \u092a\u0921\u093c\u0924\u0940\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-visual-inspection\">1. \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p><strong>\u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a\u0947\u0902:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092c\u093e\u0939\u0930\u0940 \u0938\u094d\u0935\u091a\u094d\u091b\u0924\u093e<\/strong>\u0907\u0902\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u092a\u0930 \u0927\u0942\u0932 \u0915\u093e \u091c\u092e\u093e\u0935 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u092a\u0925 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li><strong>\u0928\u092e\u0940 \u0915\u093e \u092a\u094d\u0930\u0935\u0947\u0936<\/strong>: \u0938\u0902\u0918\u0928\u0928, \u092a\u093e\u0928\u0940 \u0915\u0947 \u0926\u093e\u0917 (\u0935\u093f\u0936\u0947\u0937\u0915\u0930 \u092c\u093e\u0939\u0930\u0940\/\u0928\u092e\u0940\u092f\u0941\u0915\u094d\u0924 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u092e\u0947\u0902)<\/li>\n\n\n\n<li><strong>\u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f<\/strong>: \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902, \u092e\u0941\u0921\u093c\u0947 \u0939\u0941\u090f \u092a\u0941\u0930\u094d\u091c\u0947, \u092a\u094d\u0930\u092d\u093e\u0935 \u0915\u0947 \u0928\u093f\u0936\u093e\u0928<\/li>\n\n\n\n<li><strong>\u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923<\/strong>\u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u092c\u094b\u0932\u094d\u091f \u0915\u093f\u090f \u0917\u090f \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u092a\u0930, \u0915\u0947\u092c\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928<\/li>\n\n\n\n<li><strong>\u0915\u0940\u091f\/\u091a\u0942\u0939\u0947 \u0915\u0940 \u0917\u0924\u093f\u0935\u093f\u0927\u093f<\/strong>: \u0918\u094b\u0902\u0938\u0932\u0947, \u092e\u0932, \u091a\u092c\u093e\u092f\u093e \u0939\u0941\u0906 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928<\/li>\n\n\n\n<li><strong>\u0935\u093e\u092f\u0941 \u0938\u0902\u091a\u093e\u0930<\/strong>: \u090f\u092f\u0930 \u0935\u0947\u0902\u091f\u094d\u0938 \u0905\u0935\u0930\u094b\u0927\u0930\u0939\u093f\u0924, \u092a\u0902\u0916\u0947 \u091a\u093e\u0932\u0942 (\u092f\u0926\u093f \u0932\u093e\u0917\u0942 \u0939\u094b)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092e\u093e\u0928\u0926\u0902\u0921<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0915\u094b\u0908 \u0926\u0943\u0936\u094d\u092f\u092e\u093e\u0928 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0928\u0939\u0940\u0902 (\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u092a\u0930 \u0915\u093e\u0930\u094d\u092c\u0928 \u092a\u0925)<\/li>\n\n\n\n<li>\u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u092e\u0947\u0902 1 \u092e\u093f\u092e\u0940 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u0940 \u0915\u094b\u0908 \u0926\u0930\u093e\u0930 \u0928\u0939\u0940\u0902\u0964<\/li>\n\n\n\n<li>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u0947 \u0915\u094b\u0908 \u0938\u092c\u0942\u0924 \u0928\u0939\u0940\u0902 (\u0930\u0902\u0917 \u092c\u0926\u0932\u0928\u093e, \u092a\u093f\u0918\u0932\u0947 \u0939\u0941\u090f \u092a\u0941\u0930\u094d\u091c\u0947)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0907\u091c\u093c\u094b\u092a\u094d\u0930\u094b\u092a\u093e\u0907\u0932 \u0905\u0932\u094d\u0915\u094b\u0939\u0932 \u0914\u0930 \u0932\u093f\u0902\u091f-\u092b\u094d\u0930\u0940 \u0915\u092a\u0921\u093c\u0947 \u0938\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0928\u092e\u0940\/\u0915\u0940\u091f \u0915\u0947 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0948\u092c\u093f\u0928\u0947\u091f \u092e\u0947\u0902 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0926\u0930\u093e\u0930\u094b\u0902 \u0915\u094b \u0938\u0940\u0932 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0935\u093e\u092a\u0938 \u0932\u093e\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u092b\u091f\u0947 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0930 \u092c\u0926\u0932\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-mechanical-operation-test\">2. \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u0905\u0932\u0917 \u0915\u093f\u092f\u093e \u0917\u092f\u093e \u0939\u0948 \u0914\u0930 \u091f\u0948\u0917 \u0932\u0917\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u091a\u093e\u0930\u094d\u091c \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917 \u092e\u094b\u091f\u0930 \u092f\u093e \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u0932\u093f\u0915 \u092a\u0902\u092a)<\/li>\n\n\n\n<li>\u092e\u0948\u0928\u0941\u0905\u0932 \u092f\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092c\u0902\u0926 \u0915\u0930\u0928\u0947 \u0915\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0928\u093f\u0939\u093e\u0930\u0947\u0902:\n<ul class=\"wp-block-list\">\n<li>\u092c\u093f\u0928\u093e \u0939\u093f\u091a\u0915\u093f\u091a\u093e\u0939\u091f \u092f\u093e \u0905\u091f\u0915\u0928 \u0915\u0947 \u0938\u0941\u091a\u093e\u0930\u0942 \u0917\u0924\u093f<\/li>\n\n\n\n<li>\u092c\u0902\u0926 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0938\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0932\u0948\u091a\u093f\u0902\u0917<\/li>\n\n\n\n<li>\u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917 \u092e\u094b\u091f\u0930 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u091a\u093e\u0930\u094d\u091c \u0939\u094b\u0928\u0947 \u092a\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u092c\u0902\u0926 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u092f\u093e\u0924\u094d\u0930\u093e \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0928\u093f\u0939\u093e\u0930\u0947\u0902:\n<ul class=\"wp-block-list\">\n<li>\u0924\u094d\u0935\u0930\u093f\u0924 \u092a\u094d\u0930\u0924\u093f\u0915\u094d\u0930\u093f\u092f\u093e (&lt;100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921, \u091f\u094d\u0930\u093f\u092a \u0938\u093f\u0917\u094d\u0928\u0932 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u0932\u0917\u093e\u0935 \u0906\u0930\u0902\u092d \u0939\u094b\u0928\u0947 \u0924\u0915)<\/li>\n\n\n\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u091f\u0942\u091f\u0928\u0947 \u0915\u0940 \u0927\u094d\u0935\u0928\u093f \u0938\u0941\u0928\u093e\u0908 \u0926\u0947\u0924\u0940 \u0939\u0948<\/li>\n\n\n\n<li>\u0916\u0941\u0932\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0938\u0915\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0932\u091a\u093f\u0902\u0917<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u092a\u0942\u0930\u0947 \u0938\u094d\u091f\u094d\u0930\u094b\u0915 \u092e\u0947\u0902 \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0932\u0948\u091a \u092e\u091c\u092c\u0942\u0924\u0940 \u0938\u0947 \u091c\u0941\u0921\u093c\u0924\u0947 \u0939\u0948\u0902 (\u0915\u094b\u0908 \u0922\u0940\u0932\u093e \u092f\u093e \u0905\u0938\u094d\u092a\u0937\u094d\u091f \u091c\u0941\u0921\u093c\u093e\u0935 \u0928\u0939\u0940\u0902)<\/li>\n\n\n\n<li>\u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917 \u0930\u0947\u091f\u0947\u0921 \u0938\u092e\u092f (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 10\u201330 \u0938\u0947\u0915\u0902\u0921) \u0915\u0947 \u092d\u0940\u0924\u0930 \u092a\u0942\u0930\u0940 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0935\u093f\u0935\u0930\u0923 \u0938\u0939\u093f\u0924 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0926\u0930\u094d\u0936\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092e\u0941\u0926\u094d\u0926\u0947<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0927\u0940\u092e\u0940 \u092f\u093e \u0905\u0928\u093f\u092f\u092e\u093f\u0924 \u0917\u0924\u093f \u2192 \u0938\u094d\u0928\u0947\u0939\u0928 \u0938\u092e\u0938\u094d\u092f\u093e, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935<\/li>\n\n\n\n<li>\u0932\u0948\u091a \u0928 \u0932\u0917\u0928\u093e \u2192 \u0932\u0948\u091a \u0915\u093e \u0918\u093f\u0938\u0928\u093e, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u0940 \u0925\u0915\u093e\u0928, \u0938\u0902\u0930\u0947\u0916\u0923 \u0926\u094b\u0937<\/li>\n\n\n\n<li>\u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917 \u092e\u094b\u091f\u0930 \u0932\u0917\u093e\u0924\u093e\u0930 \u091a\u0932\u0924\u0940 \u0930\u0939\u0924\u0940 \u0939\u0948 \u2192 \u0932\u093f\u092e\u093f\u091f \u0938\u094d\u0935\u093f\u091a \u0915\u0940 \u0916\u0930\u093e\u092c\u0940, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0905\u091f\u0915\u093e\u0935<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-control-circuit-verification\">3. \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925 \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/h3>\n\n\n\n<p><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u093e\u092a\u0928<\/strong>:<\/p>\n\n\n\n<p>\u0921\u0940\u0938\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u092f\u0939\u093e\u0901 \u092e\u093e\u092a\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u091f\u094d\u0930\u093f\u092a \u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n\n\n\n<li>\u0915\u094d\u0932\u094b\u091c \u0911\u092a\u0930\u0947\u0936\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0949\u0907\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u094b \u092c\u0902\u0926 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0938\u0939\u093e\u092f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f<\/strong>: \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u093e 85\u2013110% (\u0909\u0926\u093e\u0939\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f, 125 VDC \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0932\u093f\u090f 110\u2013138 V)<\/p>\n\n\n\n<p><strong>\u0928\u093f\u092e\u094d\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c (&lt;85%)<\/strong>: \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a, \u0915\u092e\u091c\u094b\u0930 \u092c\u0948\u091f\u0930\u0940, \u091a\u093e\u0930\u094d\u091c\u0930 \u0915\u0940 \u0916\u0930\u093e\u092c\u0940 \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948<br><strong>\u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c (&gt;110%)<\/strong>: \u091a\u093e\u0930\u094d\u091c\u0930 \u0915\u0940 \u0916\u0930\u093e\u092c\u0940, \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u0949\u0907\u0932 \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948<\/p>\n\n\n\n<p><strong>\u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u091c\u093e\u0901\u091a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0915\u094b\u0908 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0902\u0926 \u0928 \u0939\u094b\u0964<\/li>\n\n\n\n<li>\u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u092c\u094d\u0930\u0947\u0915\u0930 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u092a\u0930 \u090f\u0928\u0938\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u0916\u0941\u0932\u0947 \u0939\u094b\u0902\u0964<\/li>\n\n\n\n<li>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u0928\u093f\u0930\u0902\u0924\u0930 \u0939\u094b (\u0905\u0902\u0924\u0930\u093e\u0932 \u0930\u0939\u093f\u0924)<\/li>\n\n\n\n<li>\u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u093e \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0928\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 (\u0905\u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u094b \u0930\u094b\u0915\u0947\u0902)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-connection-torque-check\">4. \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u091f\u0949\u0930\u094d\u0915 \u091c\u093e\u0901\u091a<\/h3>\n\n\n\n<p><strong>\u0906\u0932\u094b\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u0938\u0902\u092c\u0902\u0927<\/strong>&nbsp;(\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0906\u0915\u0938\u094d\u092e\u093f\u0915 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092c\u094d\u0930\u0947\u0915\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0938\u0947 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u092c\u0938\u092c\u093e\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/li>\n\n\n\n<li>\u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n\n\n\n<li>\u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u0932\u093f\u0902\u0915 \u092c\u094b\u0932\u094d\u091f<\/li>\n\n\n\n<li>\u092a\u0948\u0928\u0932 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u092c\u094b\u0932\u094d\u091f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f\u0947\u0921 \u091f\u0949\u0930\u094d\u0915 \u0930\u0947\u0902\u091a \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902<\/strong>&nbsp;\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M10 \u092c\u094b\u0932\u094d\u091f: 45\u201355 \u0928\u094d\u092f\u0942\u091f\u0928-\u092e\u0940\u091f\u0930<\/li>\n\n\n\n<li>M12 \u092c\u094b\u0932\u094d\u091f: 70\u201385 \u0928\u094d\u092f\u0942\u091f\u0928-\u092e\u0940\u091f\u0930<\/li>\n\n\n\n<li>\u092e\u0941\u0916\u094d\u092f \u092c\u0938\u092c\u093e\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928: 100\u2013200 N\u00b7m (\u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u092d\u093f\u0928\u094d\u0928)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092c\u094b\u0932\u094d\u091f \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0915\u093e \u0930\u0902\u0917 \u092b\u0940\u0915\u093e \u092a\u0921\u093c\u0928\u093e<\/li>\n\n\n\n<li>\u0938\u0924\u0939\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0926\u093f\u0916\u093e\u0908 \u0926\u0947\u0928\u0947 \u0935\u093e\u0932\u0940 \u0916\u093e\u0908<\/li>\n\n\n\n<li>\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0938\u0947 \u0915\u092e \u091f\u0949\u0930\u094d\u0915 \u092e\u093e\u0928<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-environmental-documentation\">5. \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923<\/h3>\n\n\n\n<p>\u091f\u094d\u0930\u0947\u0902\u0921\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0930\u093f\u0915\u0949\u0930\u094d\u0921:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u0930\u093f\u0935\u0947\u0936 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928<\/strong>&nbsp;\u0905\u0902\u0926\u0930\u0942\u0928\u0940 \u092a\u0948\u0928\u0932<\/li>\n\n\n\n<li><strong>\u0938\u093e\u092a\u0947\u0915\u094d\u0937 \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e<\/strong><\/li>\n\n\n\n<li><strong>\u0926\u0942\u0937\u093f\u0924 \u0938\u094d\u0924\u0930<\/strong>&nbsp;(\u0938\u093e\u092b \/ \u0939\u0932\u094d\u0915\u0940 \u0927\u0942\u0932 \/ \u092d\u093e\u0930\u0940 \u0938\u0902\u0926\u0942\u0937\u0923)<\/li>\n\n\n\n<li><strong>\u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f<\/strong>&nbsp;(\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \/ \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927\u093f\u0924)<\/li>\n<\/ul>\n\n\n\n<p>\u0909\u091a\u094d\u091a \u0924\u093e\u092a\u092e\u093e\u0928 (&gt;40\u00b0C \u0928\u093f\u0930\u0902\u0924\u0930) \u092f\u093e \u0909\u091a\u094d\u091a \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e (&gt;85% \u0906\u0930\u090f\u091a) \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u0915\u094b \u0924\u0947\u091c \u0915\u0930 \u0926\u0947\u0924\u093e \u0939\u0948\u2014\u0936\u093e\u092f\u0926 \u0921\u0947\u0930\u0947\u091f\u093f\u0902\u0917 \u092f\u093e \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"annual-maintenance-detailed-testing\">\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935: \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h2>\n\n\n\n<p>\u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u093e\u092a\u0928\u0940\u092f \u092e\u093e\u092a\u0926\u0902\u0921\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u094b \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-contact-resistance-measurement\">1. \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928<\/h3>\n\n\n\n<p><strong>\u0909\u0926\u094d\u0926\u0947\u0936\u094d\u092f<\/strong>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0905\u0924\u093f\u0924\u093e\u092a\u0928 \u092f\u093e \u0915\u094d\u0937\u092e\u0924\u093e \u0939\u093e\u0928\u093f \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923, \u0938\u0902\u0926\u0942\u0937\u0923 \u0914\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 \u0924\u094d\u0930\u0941\u091f\u093f \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u090f\u0901\u0964 \u092b\u0940\u0932\u094d\u0921 \u0938\u0947\u091f\u0905\u092a \u0935\u093f\u0935\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0907\u0938\u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/micro-ohm-contact-resistance-testing\/\">\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u092e \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/a>.<\/p>\n\n\n\n<p><strong>\u0909\u092a\u0915\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930: 100 A \u092f\u093e 200 A \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e (\u0928\u094d\u092f\u0942\u0928\u0924\u092e)<\/li>\n\n\n\n<li>\u091f\u0947\u0938\u094d\u091f \u0932\u0940\u0921 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0947\u0932\u094d\u0935\u093f\u0928 (4-\u0924\u093e\u0930) \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/li>\n\n\n\n<li>\u092a\u093f\u091b\u0932\u0947 12 \u092e\u0939\u0940\u0928\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0905\u0932\u0917 \u0915\u0930\u0947\u0902 (\u0921\u0940-\u090f\u0928\u0930\u094d\u091c\u093e\u0907\u091c\u093c\u0947\u0936\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0947\u0902)<\/li>\n\n\n\n<li>\u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u092c\u0902\u0926 \u0915\u0930\u0947\u0902 (\u092e\u0948\u0928\u094d\u092f\u0941\u0905\u0932\u0940 \u092f\u093e \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0930\u0942\u092a \u0938\u0947)<\/li>\n\n\n\n<li>\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930 \u0915\u0947 \u0915\u0947\u0932\u094d\u0935\u093f\u0928 \u0915\u094d\u0932\u093f\u092a\u094d\u0938 \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902, \u0930\u0940\u0921\u093f\u0902\u0917 \u0915\u0947 \u0938\u094d\u0925\u093f\u0930 \u0939\u094b\u0928\u0947 \u0924\u0915 \u092a\u094d\u0930\u0924\u0940\u0915\u094d\u0937\u093e \u0915\u0930\u0947\u0902 (5\u201310 \u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li>\u092a\u094d\u0930\u0924\u093f \u092a\u094b\u0932 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e (\u03bc\u03a9) \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0924\u0940\u0928\u094b\u0902 \u091a\u0930\u0923\u094b\u0902 \u0915\u094b \u092e\u093e\u092a\u0947\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>12\u201336 kV VCBs \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092e\u093e\u0928<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0928\u090f \u0938\u0902\u092a\u0930\u094d\u0915<\/strong>: 30\u201380 \u03bc\u03a9 \u092a\u094d\u0930\u0924\u093f \u0927\u094d\u0930\u0941\u0935<\/li>\n\n\n\n<li><strong>\u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e<\/strong>: 150 \u03bc\u03a9 \u0905\u0927\u093f\u0915\u0924\u092e<\/li>\n\n\n\n<li><strong>\u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0940\u092e\u093e<\/strong>: &gt;120 \u03bc\u03a9 \u092f\u093e \u092e\u0942\u0932 \u0906\u0927\u093e\u0930\u0930\u0947\u0916\u093e \u0915\u093e 2\u00d7<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/th><th>\u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f<\/th><th>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/th><\/tr><\/thead><tbody><tr><td>&lt;80 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>\u0938\u094d\u0925\u093f\u0930<\/td><td>\u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948, \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u091c\u093e\u0930\u0940 \u0930\u0916\u0947\u0902<\/td><\/tr><tr><td>80\u2013120 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>\u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u092c\u0922\u093c\u0928\u093e<\/td><td>\u0905\u0917\u0932\u0947 \u0905\u0902\u0924\u0930\u093e\u0932 \u092a\u0930 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u0930\u0947\u0902, \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e \u092c\u0928\u093e\u090f\u0901<\/td><\/tr><tr><td>120 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>\u0938\u0940\u092e\u093e \u0928\u093f\u0915\u091f \u0906 \u0930\u0939\u0940 \u0939\u0948<\/td><td>\u0905\u0917\u0932\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td>\u0967\u096b\u0966 \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u0913\u092e<\/td><td>\u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e \u092a\u093e\u0930 \u0939\u094b \u0917\u0908<\/td><td>\u0924\u0924\u094d\u0915\u093e\u0932 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948<\/td><\/tr><tr><td>\u0905\u091a\u093e\u0928\u0915 \u0909\u091b\u093e\u0932 (&gt;50% \u0915\u0940 \u0935\u0943\u0926\u094d\u0927\u093f)<\/td><td>\u0905\u0938\u093e\u092e\u093e\u0928\u094d\u092f<\/td><td>\u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0947 \u0932\u093f\u090f \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902; \u092f\u0926\u093f \u092a\u0941\u0937\u094d\u091f\u093f \u0939\u094b \u091c\u093e\u090f, \u0924\u094b \u0938\u0902\u0930\u0947\u0916\u0923 \u0926\u094b\u0937 \u092f\u093e \u0938\u0902\u0926\u0942\u0937\u0923 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>\u0927\u094d\u0930\u0941\u0935-\u0938\u0947-\u0927\u094d\u0930\u0941\u0935 \u092d\u093f\u0928\u094d\u0928\u0924\u093e<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&lt;20% \u0905\u0902\u0924\u0930 = \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f<\/li>\n\n\n\n<li>30% \u0905\u0902\u0924\u0930 = \u0905\u0938\u092e\u093e\u0928 \u0918\u093f\u0938\u093e\u0935 \u0915\u093e \u0938\u0902\u0915\u0947\u0924, \u0924\u0902\u0924\u094d\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart.webp\" alt=\"\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u091a\u093e\u0930\u094d\u091f \u091c\u094b \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0938\u093e\u0925 \u0915\u094d\u0930\u092e\u093f\u0915 \u0935\u0943\u0926\u094d\u0927\u093f \u0926\u093f\u0916\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u092f\u094b\u091c\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0906\u0927\u093e\u0930 \u0930\u0947\u0916\u093e, \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0938\u0940\u092e\u093e \u0914\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0940\u092e\u093e \u091a\u093f\u0939\u094d\u0928\u093f\u0924 \u0939\u0948\u0902\u0964\" class=\"wp-image-2540\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-resistance-trending-chart-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u091a\u093f\u0924\u094d\u0930 2**: \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u2014\u092c\u0947\u0938\u0932\u093e\u0907\u0928 (50 \u03bc\u03a9) \u0938\u0947 \u092e\u0949\u0928\u093f\u091f\u0930 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 (80 \u03bc\u03a9) \u0924\u0915 \u0930\u0948\u0916\u093f\u0915 \u090f\u0915\u094d\u0938\u091f\u094d\u0930\u092a\u0932\u0947\u0936\u0928 6\u201312 \u092e\u0939\u0940\u0928\u094b\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0938\u0940\u092e\u093e (120 \u03bc\u03a9) \u0924\u0915 \u092a\u0939\u0941\u0902\u091a\u0928\u0947 \u0915\u093e \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928 \u0926\u0947\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0947 \u092c\u091c\u093e\u092f \u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0906\u0909\u091f\u0947\u091c \u0936\u0947\u0921\u094d\u092f\u0942\u0932\u093f\u0902\u0917 \u0938\u0902\u092d\u0935 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-timing-and-travel-test\">2. \u0938\u092e\u092f \u0914\u0930 \u092f\u093e\u0924\u094d\u0930\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0915\u0940 \u0935\u093f\u0918\u091f\u0928 \u0915\u094d\u0937\u092e\u0924\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0917\u0924\u093f \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0924\u0902\u0924\u094d\u0930 \u0915\u0947 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0907\u0928\u094d\u0939\u0947\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/vcb-contact-gap-adjustment-factory-field\/\">\u0938\u0902\u092a\u0930\u094d\u0915-\u0905\u0902\u0924\u0930 \u0914\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 \u0938\u0940\u092e\u093e\u090f\u0901<\/a>&nbsp;\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u092e\u093e\u092f\u094b\u091c\u0928 \u0938\u0947 \u092a\u0939\u0932\u0947.<\/p>\n\n\n\n<p><strong>\u0906\u0935\u0936\u094d\u092f\u0915 \u0909\u092a\u0915\u0930\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 (\u0938\u092e\u0930\u094d\u092a\u093f\u0924 VCB \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947\u091f)<\/li>\n\n\n\n<li>\u092f\u093e: \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0924\u093f \u091f\u094d\u0930\u093e\u0902\u0938\u0921\u094d\u092f\u0942\u0938\u0930\u094b\u0902 \u0935\u093e\u0932\u093e \u0909\u091a\u094d\u091a-\u0917\u0924\u093f \u0930\u093f\u0915\u0949\u0930\u094d\u0921\u0930<\/li>\n\n\n\n<li>\u092a\u093f\u091b\u0932\u0947 12 \u092e\u0939\u0940\u0928\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f \u0915\u093f\u092f\u093e \u0917\u092f\u093e<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092e\u093e\u092a<\/strong>:<\/p>\n\n\n\n<p><strong>\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f<\/strong>\u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e-\u0938\u0902\u091a\u093e\u0930\u0923 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0924\u0915 \u0915\u093e \u0938\u092e\u092f<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0906\u092e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 12\u201324 kV VCBs \u0915\u0947 \u0932\u093f\u090f 30\u201360 ms, 36\u201340.5 kV \u0915\u0947 \u0932\u093f\u090f 50\u201380 ms<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f<\/strong>\u0915\u094b\u0907\u0932 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u092a\u0930\u094d\u0936 \u0924\u0915 \u0915\u093e \u0938\u092e\u092f<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0906\u092e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 60\u2013100 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e<\/strong>: \u0915\u0941\u0932 \u0926\u0942\u0930\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0916\u0941\u0932\u0947 \u0938\u0947 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u092c\u0902\u0926 \u0924\u0915 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0906\u092e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 12\u201324 kV \u0915\u0947 \u0932\u093f\u090f 10\u201316 \u092e\u093f\u092e\u0940, 36\u201340.5 kV \u0915\u0947 \u0932\u093f\u090f 14\u201320 \u092e\u093f\u092e\u0940<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0935\u0947\u0917<\/strong>\u0916\u0941\u0932\u0928\u0947 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0914\u0938\u0924 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0917\u0924\u093f<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0906\u092e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 1.0\u20132.5 \u092e\u0940\/\u0938\u0947 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0924\u0902\u0924\u094d\u0930), 2.0\u20134.0 \u092e\u0940\/\u0938\u0947 (\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u090f\u0915\u094d\u091f\u094d\u092f\u0942\u090f\u091f\u0930\u094d\u0938)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0915\u094b VCB \u0915\u0947 \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092f\u093e \u0938\u0940\u0927\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0947\u0902\u0938\u0930\u094b\u0902 \u0938\u0947 \u0915\u0928\u0947\u0915\u094d\u091f \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0915 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u091f\u094d\u0930\u093f\u0917\u0930 \u091f\u094d\u0930\u093f\u092a \u0938\u0902\u091a\u093e\u0932\u0928<\/li>\n\n\n\n<li>\u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f, \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930, \u0935\u0947\u0917 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0928\u091c\u093c\u0926\u0940\u0915\u0940 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0926\u094b\u0939\u0930\u093e\u090f\u0901<\/li>\n\n\n\n<li>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0924\u0940\u0928 \u092e\u093e\u092a \u0915\u0930\u0947\u0902, \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u093e \u0914\u0938\u0924 \u0928\u093f\u0915\u093e\u0932\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092e\u093e\u0928\u0926\u0902\u0921<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f: \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0915\u0947 \u00b110% \u0915\u0947 \u092d\u0940\u0924\u0930<\/li>\n\n\n\n<li>\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f: \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0915\u0947 \u00b115% \u0915\u0947 \u092d\u0940\u0924\u0930 (\u0916\u094b\u0932\u0928\u0947 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u092e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923)<\/li>\n\n\n\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e: \u0930\u0947\u091f\u0947\u0921 \u092f\u093e\u0924\u094d\u0930\u093e \u0915\u093e 90\u2013110%<\/li>\n\n\n\n<li>\u0935\u0947\u0917: \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0935\u0947\u0917 \u0915\u0947 &gt;80%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0938\u0940\u092e\u093e \u0938\u0947 \u092c\u093e\u0939\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u093e\u0901<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0932\u0915\u094d\u0937\u0923<\/th><th>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/th><th>\u0909\u092a\u091a\u093e\u0930<\/th><\/tr><\/thead><tbody><tr><td>\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u0927\u0940\u092e\u093e (&gt;10% \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0905\u0927\u093f\u0915)<\/td><td>\u0938\u0942\u0916\u093e \u0938\u094d\u0928\u0947\u0927\u0915, \u0935\u0938\u0902\u0924 \u0925\u0915\u093e\u0928, \u0918\u0930\u094d\u0937\u0923<\/td><td>\u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u0930\u0947\u0902, \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td>\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u0924\u0947\u091c\u093c (&gt;10% \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u0915\u092e)<\/td><td>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0924\u0928\u0947 \u0939\u0941\u090f \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u0915\u092e \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917<\/td><td>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0924\u0928\u093e\u0935 \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902, \u0921\u0948\u092e\u094d\u092a\u0930 \u091c\u093e\u0901\u091a\u0947\u0902\u0964<\/td><\/tr><tr><td>\u0905\u0938\u0902\u0917\u0924 \u0938\u092e\u092f-\u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 (\u0911\u092a\u0930\u0947\u0936\u0928\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a &gt;15% \u0924\u0915 \u092d\u093f\u0928\u094d\u0928)<\/td><td>\u092c\u093e\u0907\u0902\u0921\u093f\u0902\u0917, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0916\u0947\u0932, \u0932\u0945\u091a \u0918\u093f\u0938\u093e\u0935\u091f<\/td><td>\u092f\u0902\u0924\u094d\u0930 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902, \u0918\u093f\u0938\u0947 \u0939\u0941\u090f \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u094b \u092c\u0926\u0932\u0947\u0902\u0964<\/td><\/tr><tr><td>\u0928\u093f\u092e\u094d\u0928 \u092f\u093e\u0924\u094d\u0930\u093e (&lt;90%)<\/td><td>\u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u0915\u0940 \u0918\u093f\u0938\u093e\u0935\u091f, \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0938\u0942\u091c\u0928\u093e (\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0939\u093e\u0928\u093f)<\/td><td>\u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902; \u092f\u0926\u093f \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0916\u094b \u091c\u093e\u090f, \u0924\u094b VI \u092c\u0926\u0932\u0947\u0902\u0964<\/td><\/tr><tr><td>\u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u092f\u093e\u0924\u094d\u0930\u093e (&gt;110%)<\/td><td>\u0938\u092e\u093e\u092f\u094b\u091c\u0928 \u0916\u094b \u091c\u093e\u0928\u0947 \u0915\u093e \u0916\u0924\u0930\u093e, \u0905\u0924\u093f-\u092f\u093e\u0924\u094d\u0930\u093e \u0938\u0947 \u0915\u094d\u0937\u0924\u093f \u0915\u093e \u091c\u094b\u0916\u093f\u092e<\/td><td>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u094d\u091f\u0949\u092a\u094d\u0938 \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup.webp\" alt=\"\u0935\u0940\u0938\u0940\u092c\u0940 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947\u091f\u0905\u092a, \u091c\u093f\u0938\u092e\u0947\u0902 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u092c\u094d\u0930\u0947\u0915\u0930 \u0938\u0947 \u091c\u0941\u0921\u093c\u093e \u0939\u0941\u0906 \u0939\u0948, \u0913\u092a\u0928\u093f\u0902\u0917 \u091f\u093e\u0907\u092e \u091f\u094d\u0930\u0947\u0938 \u0921\u093f\u0938\u094d\u092a\u094d\u0932\u0947 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930 \u092e\u093e\u092a\u0928 \u0926\u093f\u0916\u093e\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964\" class=\"wp-image-2541\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-timing-test-setup-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0906\u0915\u0943\u0924\u093f 3**: \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930 \u0938\u091f\u0940\u0915 \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f (\u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0915\u0947 \u090a\u0930\u094d\u091c\u093e\u0935\u093e\u0928 \u0939\u094b\u0928\u0947 \u0938\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0947 \u0905\u0932\u0917 \u0939\u094b\u0928\u0947 \u0924\u0915), \u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e \u0935\u0915\u094d\u0930, \u0914\u0930 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0935\u0947\u0917 \u0915\u094b \u0915\u0948\u092a\u094d\u091a\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u091c\u094b \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u0940 \u0926\u094b\u0937 \u0935\u093f\u0930\u093e\u092e \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u094b \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930 \u0939\u0948\u0902 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 12-24 kV VCBs \u0915\u0947 \u0932\u093f\u090f 30-60 ms \u0915\u093e \u0909\u0926\u094d\u0918\u093e\u091f\u0928 \u0938\u092e\u092f)\u0964.\n<br><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-insulation-resistance-testing\">3. \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p>\u0938\u091c\u0940\u0935 \u092d\u093e\u0917\u094b\u0902 \u0914\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0915\u0947 \u092c\u0940\u091a \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0930\u093f\u0938\u093e\u0935 \u0927\u093e\u0930\u093e\u0913\u0902 \u0914\u0930 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0915\u094b \u0930\u094b\u0915\u093e \u091c\u093e \u0938\u0915\u0947\u0964.<\/p>\n\n\n\n<p><strong>\u0909\u092a\u0915\u0930\u0923<\/strong>: \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0915 (\u092e\u0947\u0917\u0930), 2.5 kV \u092f\u093e 5 kV \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/p>\n\n\n\n<p><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092c\u093f\u0902\u0926\u0941<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u092b\u0947\u091c-\u091f\u0942-\u0917\u094d\u0930\u093e\u0909\u0902\u0921<\/strong>&nbsp;(\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u092a\u094b\u0932 \u0905\u0932\u0917 \u0938\u0947):\n<ul class=\"wp-block-list\">\n<li>\u092c\u094d\u0930\u0947\u0915\u0930 \u0916\u0941\u0932\u093e: \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0924\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f: &gt;1,000 M\u03a9<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u091a\u0930\u0923-\u0938\u0947-\u091a\u0930\u0923<\/strong>&nbsp;(\u092c\u094d\u0930\u0947\u0915\u0930 \u0916\u0941\u0932\u093e):\n<ul class=\"wp-block-list\">\n<li>\u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0927\u094d\u0930\u0941\u0935\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f: &gt;1,000 M\u03a9<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925 \u0915\u094b \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0938\u0947 \u091c\u094b\u0921\u093c\u0947\u0902<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928<\/li>\n\n\n\n<li>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f: &gt;10 M\u03a9 (\u0938\u0902\u092f\u094b\u091c\u093f\u0924 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092e\u0941\u0916\u094d\u092f \u092a\u0930\u093f\u092a\u0925 \u0938\u0947 \u0915\u092e)<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0928\u093f\u092e\u094d\u0928 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong>&nbsp;(\u092e\u0941\u0916\u094d\u092f \u092a\u0930\u093f\u092a\u0925 \u092a\u0930 &lt;100 M\u03a9):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0902\u0915\u0947\u0924 \u0915\u0930\u0924\u093e \u0939\u0948: \u0928\u092e\u0940 \u0915\u093e \u092a\u094d\u0930\u0935\u0947\u0936, \u0938\u0902\u0926\u0942\u0937\u0923, \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917, \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u0924\u093f<\/li>\n\n\n\n<li>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908: \u0938\u0941\u0916\u093e\u090f\u0901, \u0938\u093e\u092b \u0915\u0930\u0947\u0902, \u0926\u0930\u093e\u0930\u094b\u0902\/\u0928\u0941\u0915\u0938\u093e\u0928 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902; \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0947 \u092c\u093e\u0926 \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092a\u094d\u0930\u091a\u0932\u093f\u0924<\/strong>\u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094b \u091f\u094d\u0930\u0948\u0915 \u0915\u0930\u0947\u0902\u0964  \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0915\u092e\u0940 \u0935\u093f\u0915\u0938\u093f\u0924 \u0939\u094b\u0924\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948, \u092d\u0932\u0947 \u0939\u0940 \u092f\u0939 \u0905\u092d\u0940 \u092d\u0940 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0938\u0947 \u090a\u092a\u0930 \u0939\u094b\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-vacuum-integrity-check\">4. \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u091c\u093e\u0901\u091a<\/h3>\n\n\n\n<p>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0940 \u0921\u093e\u0907\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0909\u091a\u094d\u091a \u0935\u0948\u0915\u094d\u092f\u0942\u092e (&lt;10\u207b\u2074 Pa) \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0916\u094b \u091c\u093e\u0928\u0947 \u0938\u0947 \u0932\u094b\u0921 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0930\u094b\u0915\u0940 \u0928\u0939\u0940\u0902 \u091c\u093e \u0938\u0915\u0924\u0940, \u0932\u0947\u0915\u093f\u0928 \u0926\u094b\u0937 \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092f\u0939 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0930\u0942\u092a \u0938\u0947 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u0935\u093f\u0927\u093f 1: \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>&nbsp;(\u0938\u092c\u0938\u0947 \u0928\u093f\u0930\u094d\u0923\u093e\u092f\u0915)<\/p>\n\n\n\n<p><strong>\u0909\u092a\u0915\u0930\u0923<\/strong>\u090f\u0938\u0940 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0947\u091f, 10\u201350 kV \u0938\u092e\u093e\u092f\u094b\u091c\u094d\u092f<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u094b \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0916\u0941\u0932\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 BIL \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u093e 70\u201380%)\n<ul class=\"wp-block-list\">\n<li>\u0909\u0926\u093e\u0939\u0930\u0923: 12 kV VCB, 75 kV BIL \u2192 ~55 kV AC \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>1 \u092e\u093f\u0928\u091f \u0924\u0915 \u0930\u094b\u0915\u0947\u0902<\/li>\n\n\n\n<li>\u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0915\u0947 \u0932\u093f\u090f \u0905\u0935\u0932\u094b\u0915\u0928 \u0915\u0930\u0947\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 \u0928\u0939\u0940\u0902 = \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0915\u094d\u0937\u0941\u0923\u094d\u0923<\/li>\n\n\n\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0947 \u0928\u0940\u091a\u0947 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930 = \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0935\u093f\u092b\u0932, \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0926\u0932\u0947\u0902<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0935\u093f\u0927\u093f 2: \u0915\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong>&nbsp;(\u092e\u0948\u0926\u093e\u0928\u0940 \u091c\u0941\u0917\u093e\u0921\u093c)<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u092e\u0947\u0917\u0930 \u0938\u0947 \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 1,000\u20132,500 V DC \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0905\u091a\u094d\u091b\u093e \u0935\u094b\u0932\u094d\u091f\u0947\u091c: &gt;100 M\u03a9, \u0938\u094d\u0925\u093f\u0930 \u0930\u0940\u0921\u093f\u0902\u0917<\/li>\n\n\n\n<li>\u0935\u093f\u092b\u0932 \u0935\u0948\u0915\u094d\u092f\u0942\u092e: &lt;50 M\u03a9, \u0905\u0928\u093f\u092f\u092e\u093f\u0924 \u0930\u0940\u0921\u093f\u0902\u0917, \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u092b\u094d\u0932\u0948\u0936\u0913\u0935\u0930<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u092e \u0928\u093f\u0936\u094d\u091a\u093f\u0924, \u0932\u0947\u0915\u093f\u0928 \u0928\u093f\u092f\u092e\u093f\u0924 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924\u0964.<\/strong><\/p>\n\n\n\n<p><strong>\u0935\u093f\u0927\u093f 3: \u0936\u0940\u0932\u094d\u0921 \u0927\u093e\u0930\u093e \u092e\u093e\u092a\u0928<\/strong>&nbsp;(\u0909\u0928\u094d\u0928\u0924, \u0935\u093f\u0936\u0947\u0937 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e)<\/p>\n\n\n\n<p>\u0915\u0941\u091b \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0917\u0948\u0930-\u0906\u0915\u094d\u0930\u093e\u092e\u0915 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0947 \u0932\u093f\u090f \u0936\u0940\u0932\u094d\u0921 \u0915\u0930\u0902\u091f \u092e\u093e\u092a\u0928 \u092a\u094b\u0930\u094d\u091f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-operating-mechanism-inspection\">5. \u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u0915\u093e \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n\n\n\n<p><strong>\u0938\u094d\u0928\u0947\u0939\u0928 \u091c\u093e\u0901\u091a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0917\u094d\u0930\u0940\u0938 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f<\/strong>: \u0938\u094d\u0935\u091a\u094d\u091b, \u0909\u091a\u093f\u0924 \u092c\u0928\u093e\u0935\u091f (\u0928 \u0924\u094b \u0938\u0942\u0916\u0940, \u0928 \u0939\u0940 \u0924\u0930\u0932)<\/li>\n\n\n\n<li><strong>\u0938\u094d\u0928\u0947\u0939\u0928 \u092c\u093f\u0902\u0926\u0941<\/strong>: \u0938\u092d\u0940 \u092a\u093f\u0935\u091f \u092c\u093f\u0902\u0926\u0941, \u092b\u093f\u0938\u0932\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u0924\u0939\u0947\u0902, \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/li>\n\n\n\n<li><strong>\u0926\u0942\u0937\u0923<\/strong>\u0927\u0942\u0932\/\u0928\u092e\u0940 \u0938\u0947 \u092e\u0941\u0915\u094d\u0924 \u091a\u093f\u0915\u0928\u093e\u0908<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u092c\u0947\u092f\u0930\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u0918\u0942\u0930\u094d\u0923\u0928 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0938\u0947 \u092a\u0941\u0930\u093e\u0928\u093e \u091a\u093f\u0915\u0928\u093e\u0908 \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0938\u094d\u0928\u0947\u0939\u0915 \u0932\u0917\u093e\u090f\u0901 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0932\u093f\u0925\u093f\u092f\u092e-\u0906\u0927\u093e\u0930\u093f\u0924, -40 \u0938\u0947 +125\u00b0C \u0924\u0915 \u0930\u0947\u091f\u0947\u0921)<\/li>\n\n\n\n<li>\u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u091a\u093f\u0915\u0928\u093e\u0908 \u0938\u0947 \u092c\u091a\u0947\u0902 (\u0927\u0942\u0932 \u0906\u0915\u0930\u094d\u0937\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092a\u0939\u0928\u0915\u0930 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u092a\u093fivot \u091b\u0947\u0926<\/strong>\u0932\u092e\u094d\u092c\u093e\u0908 \u092c\u0922\u093c\u0928\u0947 \u0914\u0930 \u0905\u0902\u0921\u093e\u0915\u093e\u0930 \u0918\u093f\u0938\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0932\u093f\u0902\u0915\u0947\u091c \u092a\u093f\u0928<\/strong>\u0935\u094d\u092f\u093e\u0938 \u092e\u093e\u092a\u0947\u0902, \u0918\u093f\u0938\u093e\u0935\u091f \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li><strong>\u091d\u0930\u0928\u0947<\/strong>\u0926\u0930\u093e\u0930\u094b\u0902 \u0914\u0930 \u0938\u094d\u0925\u093e\u092f\u0940 \u0935\u093f\u0915\u0943\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0932\u0948\u091a\u0947\u0938<\/strong>: \u0918\u093f\u0938\u093e\u0935, \u091a\u093f\u092a\u093f\u0902\u0917, \u0938\u0924\u0939 \u0915\u0940 \u0915\u094d\u0937\u0924\u093f \u0915\u0947 \u0932\u093f\u090f \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0902\u0930\u0947\u0916\u0923 \u091c\u093e\u0901\u091a<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0916\u0941\u0932\u0947 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0924\u0940\u0928\u094b\u0902 \u092a\u094b\u0932\u094b\u0902 \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u0902\u0924\u0930\u093e\u0932 \u0938\u092e\u093e\u0928<\/li>\n\n\n\n<li>\u0927\u094d\u0930\u0941\u0935\u094b\u0902 \u092a\u0930 \u090f\u0915 \u0938\u093e\u0925 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0928\u093e\u0928\u093e\/\u0924\u094b\u0921\u093c\u0928\u093e (\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0915\u0947 \u092d\u0940\u0924\u0930, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 &lt;3 \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921)<\/li>\n\n\n\n<li>\u0938\u0902\u091a\u093e\u0932\u0928 \u0924\u0902\u0924\u094d\u0930 \u092e\u0947\u0902 \u0915\u094b\u0908 \u0926\u0943\u0936\u094d\u092f\u092e\u093e\u0928 \u092e\u094b\u0921\u093c \u092f\u093e \u0935\u093f\u091a\u0932\u0928 \u0928\u0939\u0940\u0902\u0964<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6.-auxiliary-circuit-and-relay-coordination-check\">6. \u0938\u0939\u093e\u092f\u0915 \u092a\u0930\u093f\u092a\u0925 \u0914\u0930 \u0930\u093f\u0932\u0947 \u0938\u092e\u0928\u094d\u0935\u092f \u091c\u093e\u0901\u091a<\/h3>\n\n\n\n<p><strong>\u0938\u0939\u093e\u092f\u0915 \u0930\u093f\u0932\u0947<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u090f\u0902\u091f\u0940-\u092a\u0902\u092a\u093f\u0902\u0917 \u0930\u093f\u0932\u0947 \u092b\u093c\u0902\u0915\u094d\u0936\u0928<\/li>\n\n\n\n<li>\u0932\u0949\u0915\u0906\u0909\u091f \u0930\u093f\u0932\u0947 \u0930\u0940\u0938\u0947\u091f \u0915\u094d\u0937\u092e\u0924\u093e<\/li>\n\n\n\n<li>\u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0902\u0915\u0947\u0924 \u0938\u091f\u0940\u0915\u0924\u093e<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0938\u0902\u0930\u0915\u094d\u0937\u0923 \u0930\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0930\u093f\u0932\u0947 \u092a\u093f\u0915\u0905\u092a \u0914\u0930 \u091f\u093e\u0907\u092e \u0921\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0905\u0927\u094d\u092f\u092f\u0928 \u0938\u0947 \u092e\u0947\u0932 \u0939\u094b\u0928\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li>\u092f\u0926\u093f VCB \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u0947\u0902 \u0935\u093f\u091a\u0932\u0928 \u0939\u0941\u0906 \u0939\u0948, \u0924\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u094b \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0930\u093f\u0932\u0947 \u0938\u094d\u0935-\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092b\u093c\u0902\u0915\u094d\u0936\u0928 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902 (\u092e\u093e\u0907\u0915\u094d\u0930\u094b\u092a\u094d\u0930\u094b\u0938\u0947\u0938\u0930 \u0930\u093f\u0932\u0947 \u0915\u0947 \u0932\u093f\u090f)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0918\u094b\u0937\u0923\u093e<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0905\u0932\u093e\u0930\u094d\u092e \u0938\u0902\u092a\u0930\u094d\u0915 \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0930\u093f\u092e\u094b\u091f \u0938\u0902\u0915\u0947\u0924 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (SCADA, \u092a\u0948\u0928\u0932 \u0932\u093e\u0907\u091f\u094d\u0938)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-record-template\">\u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0905\u092d\u093f\u0932\u0947\u0916 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template.webp\" alt=\"VCB \u0915\u0947 \u0932\u093f\u090f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f, \u091c\u093f\u0938\u092e\u0947\u0902 \u0909\u092a\u0915\u0930\u0923 \u0939\u0947\u0921\u0930, \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f, \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u093e\u092a\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0914\u0930 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093f\u0924 \u0921\u0947\u091f\u093e \u0938\u0902\u0917\u094d\u0930\u0939 \u0915\u0947 \u0932\u093f\u090f \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0905\u0928\u0941\u092d\u093e\u0917 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964\" class=\"wp-image-2542\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-field-record-template-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0906\u0915\u0943\u0924\u093f 4**: \u092e\u093e\u0928\u0915\u0940\u0915\u0943\u0924 \u092b\u0940\u0932\u094d\u0921 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f \u0930\u0916\u0930\u0916\u093e\u0935 \u091a\u0915\u094d\u0930\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0938\u0902\u0917\u0924 \u0921\u0947\u091f\u093e \u0938\u0902\u0917\u094d\u0930\u0939 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u2014\u0938\u0902\u0930\u091a\u093f\u0924 \u092a\u094d\u0930\u093e\u0930\u0942\u092a \u0909\u092a\u0915\u0930\u0923 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928, \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u091c\u093e\u0902\u091a, \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u093e\u0928, \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908, \u0914\u0930 \u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u091f\u094d\u0930\u0947\u0902\u0921 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0924\u0925\u093e \u0928\u093f\u092f\u093e\u092e\u0915 \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0905\u0917\u0932\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0905\u0928\u0941\u0938\u0942\u091a\u0940 \u0915\u094b \u0915\u0948\u092a\u094d\u091a\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.\n<br><\/figcaption><\/figure>\n\n\n\n<p>\u0938\u0941\u0938\u0902\u0917\u0924 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0930\u0941\u091d\u093e\u0928 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u0907\u0938 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 \u092f\u093e \u0907\u0938\u0947 \u0905\u092a\u0928\u0947 CMMS \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0905\u0928\u0941\u0915\u0942\u0932\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0930\u093f\u0915\u0949\u0930\u094d\u0921   \u0909\u092a\u0915\u0930\u0923 \u0906\u0908\u0921\u0940: ________________   \u0938\u094d\u0925\u093e\u0928: ________________   \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e: ________________   \u0938\u0940\u0930\u093f\u092f\u0932 \u0928\u0902\u092c\u0930: ________________   \u0930\u0947\u091f\u0947\u0921 \u0935\u094b\u0932\u094d\u091f\u0947\u091c: _______ kV   \u0930\u0947\u091f\u0947\u0921 \u0915\u0930\u0902\u091f: _______ A   \u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f: _______ kA   \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u093e \u0935\u0930\u094d\u0937: _______\n\n\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930: [ ] \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 [ ] \u0935\u093e\u0930\u094d\u0937\u093f\u0915 [ ] \u0926\u094b\u0937\u094b\u092a\u0930\u093e\u0902\u0924 \u0924\u093f\u0925\u093f: _______________ \u092a\u093f\u091b\u0932\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u092c\u093e\u0926 \u0938\u0902\u091a\u093e\u0932\u0928: _______ \u092a\u0930\u093f\u0935\u0947\u0936 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928: _____ \u00b0C \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e: _____ %\n\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\ufffd\ufffd\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n\n\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u091c\u093e\u0901\u091a (\u092f\u0926\u093f \u0932\u093e\u0917\u0942 \u0939\u094b):  \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923: [ ] \u092c\u093e\u0939\u0930\u0940 \u092d\u093e\u0917 \u0938\u094d\u0935\u091a\u094d\u091b, \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917 \u0928\u0939\u0940\u0902  [ ] \u0915\u094b\u0908 \u092d\u094c\u0924\u093f\u0915 \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0926\u0930\u093e\u0930 \u0928\u0939\u0940\u0902  [ ] \u0915\u094b\u0908 \u0928\u092e\u0940\/\u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u0928\u0939\u0940\u0902  [ ] \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924  \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928: [ ] \u0938\u0941\u091a\u093e\u0930\u0942 \u0930\u0942\u092a \u0938\u0947 \u092c\u0902\u0926 \u0939\u094b\u0924\u093e \u0939\u0948  [ ] \u0924\u0941\u0930\u0902\u0924 \u091f\u094d\u0930\u093f\u092a \u0939\u094b\u0924\u093e \u0939\u0948  [ ] \u092e\u091c\u092c\u0942\u0924\u0940 \u0938\u0947 \u0932\u091a \u0915\u0930\u0924\u093e \u0939\u0948  [ ] \u091a\u093e\u0930\u094d\u091c\u093f\u0902\u0917 \u092e\u094b\u091f\u0930 \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0930\u0941\u0915\u0924\u0940 \u0939\u0948\n\n\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u094b\u0932\u094d\u091f\u0947\u091c (\u092e\u093e\u092a\u093e \u0917\u092f\u093e): \u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932: _______ V (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: 85-110% \u0915\u093e _____ V) \u0915\u094d\u0932\u094b\u091c\u093c \u0915\u0949\u0907\u0932: _______ V \u0938\u0939\u093e\u092f\u0915: _______ V \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u091c\u093e\u0901\u091a: [ ] \u0915\u094b\u0908 \u0922\u0940\u0932\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0928\u0939\u0940\u0902 \u0926\u0947\u0916\u093e \u0917\u092f\u093e [ ] \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0915\u094b\u0908 \u0930\u0902\u0917 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0928\u0939\u0940\u0902\n\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u092f\u0926\u093f \u0932\u093e\u0917\u0942 \u0939\u094b):\n\n\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u03bc\u03a9): \u092b\u0947\u091c A: _______ (\u092c\u0947\u0938\u0932\u093e\u0907\u0928: _____) \u0938\u094d\u0925\u093f\u0924\u093f: [ ] \u0920\u0940\u0915 [ ] \u092e\u0949\u0928\u093f\u091f\u0930 [ ] \u092c\u0926\u0932\u0947\u0902 \u092b\u0947\u091c B: _______ (\u092c\u0947\u0938\u0932\u093e\u0907\u0928: _____) \u0938\u094d\u0925\u093f\u0924\u093f: [ ] \u0920\u0940\u0915 [ ] \u092e\u0949\u0928\u093f\u091f\u0930 [ ] \u092c\u0926\u0932\u0947\u0902 \u092b\u0947\u091c C: _______ (\u092c\u0947\u0938\u0932\u093e\u0907\u0928: _____)  \u0938\u094d\u0925\u093f\u0924\u093f: [ ] \u0920\u0940\u0915 [ ] \u0928\u093f\u0917\u0930\u093e\u0928\u0940 [ ] \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0938\u092e\u092f \u092a\u0930\u0940\u0915\u094d\u0937\u0923: \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f: _______ \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: _____ \u00b1 _____ \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u093e \u0938\u092e\u092f: _______ \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: _____ \u00b1 _____ \u092e\u093f\u0932\u0940\u0938\u0947\u0915\u0902\u0921) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923\n\u0938\u0902\u092a\u0930\u094d\u0915 \u092f\u093e\u0924\u094d\u0930\u093e: _______ \u092e\u093f\u092e\u0940 (\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: _____ \u00b1 _____ \u092e\u093f\u092e\u0940) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u0914\u0938\u0924 \u0935\u0947\u0917: _______ \u092e\u0940\/\u0938\u0947 (\u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936: _____ \u092e\u0940\/\u0938\u0947) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 (\u092e\u0947\u0917\u093e\u0913\u092e):\n\u092b\u0947\u091c A \u0938\u0947 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0924\u0915: _______ (\u0928\u094d\u092f\u0942\u0928\u0924\u092e: 1000 M\u03a9) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u092b\u0947\u091c B \u0938\u0947 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0924\u0915: _______ (\u0928\u094d\u092f\u0942\u0928\u0924\u092e: 1000 M\u03a9) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u092b\u0947\u091c C \u0938\u0947 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0924\u0915: _______ (\u0928\u094d\u092f\u0942\u0928\u0924\u092e: 1000 M\u03a9) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923\n\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f: _______ (\u0928\u094d\u092f\u0942\u0928\u0924\u092e: 10 M\u03a9) [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e: \u0909\u092a\u092f\u094b\u0917 \u0915\u0940 \u0917\u0908 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093f\u0927\u093f: [ ] HV \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e [ ] \u092e\u0947\u0917\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 [ ] \u0936\u0940\u0932\u094d\u0921 \u0915\u0930\u0902\u091f \u092a\u0930\u093f\u0923\u093e\u092e: [ ] \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 (\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921) [ ] \u0905\u0928\u0941\u0924\u094d\u0924\u0940\u0930\u094d\u0923 (\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924)\n\u092f\u0926\u093f \u0905\u0938\u092b\u0932 \u0939\u0941\u0906: \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0906\u0935\u0936\u094d\u092f\u0915: [ ] \u0939\u093e\u0901 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923: [ ] \u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f [ ] \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0918\u093f\u0938\u093e\u0935 \u0928\u0939\u0940\u0902 \u0926\u0947\u0916\u093e \u0917\u092f\u093e [ ] \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0915\u0947 \u092d\u0940\u0924\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 [ ] \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u0905\u091a\u094d\u091b\u0940 \u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u0938\u0941\u0927\u093e\u0930\u093e\u0924\u094d\u092e\u0915 \u0915\u093e\u0930\u094d\u0930\u0935\u093e\u0908 \u0915\u0940 \u0917\u0908: ____________________________________________________________ ____________________________________________________________ \u092c\u0926\u0932\u0947 \u0917\u090f \u092a\u0941\u0930\u094d\u091c\u0947: ____________________________________________________________ \u0905\u0917\u0932\u0940 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u093f\u0925\u093f: \u0924\u093e\u0930\u0940\u0916: _______________ \u092f\u093e \u0938\u0902\u091a\u093e\u0932\u0928: _______\n\n\u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f: [ ] \u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0932\u094c\u091f\u093e \u0926\u093f\u092f\u093e \u0917\u092f\u093e (\u0938\u092d\u0940 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923) [ ] \u0938\u0947\u0935\u093e \u0938\u0947 \u092c\u093e\u0939\u0930 (\u092e\u0930\u092e\u094d\u092e\u0924 \u0906\u0935\u0936\u094d\u092f\u0915) [ ] \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924: _______________ \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0915: _____________________ \u0939\u0938\u094d\u0924\u093e\u0915\u094d\u0937\u0930: __________ \u0938\u092e\u0940\u0915\u094d\u0937\u093e\u0915\u0930\u094d\u0924\u093e: ___________________ \u0926\u093f\u0928\u093e\u0902\u0915: ____________\n<\/code><\/pre>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"trending-and-predictive-maintenance\">\u092a\u094d\u0930\u091a\u0932\u093f\u0924 \u0914\u0930 \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093e\u0924\u094d\u092e\u0915 \u0930\u0916\u0930\u0916\u093e\u0935<\/h2>\n\n\n\n<p>\u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u092e\u093e\u092a \u0915\u094d\u0937\u0923\u093f\u0915 \u091a\u093f\u0924\u094d\u0930 \u0939\u0948\u0902\u0964 \u0930\u0941\u091d\u093e\u0928 \u0915\u094d\u0937\u092f \u0915\u0947 \u092a\u0948\u091f\u0930\u094d\u0928 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u0947 \u092a\u094d\u0930\u092e\u0941\u0916 \u092e\u093e\u092a\u0926\u0902\u0921<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0928\u093e\u092e \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0927\u094d\u0930\u0941\u0935 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0932\u0949\u091f \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li>\u0930\u0947\u0916\u0940\u092f \u090f\u0915\u094d\u0938\u091f\u094d\u0930\u092a\u094b\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u092c\u093f\u0902\u0926\u0941 \u0915\u0940 \u092d\u0935\u093f\u0937\u094d\u092f\u0935\u093e\u0923\u0940 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0909\u0926\u093e\u0939\u0930\u0923: \u092f\u0926\u093f 1,500 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092e\u0947\u0902 50 \u03bc\u03a9 \u0938\u0947 90 \u03bc\u03a9 \u0924\u0915 \u0935\u0943\u0926\u094d\u0927\u093f \u0939\u094b \u0930\u0939\u0940 \u0939\u0948, \u0924\u094b ~2,800 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u092a\u0930 120 \u03bc\u03a9 \u0915\u0940 \u0938\u0940\u092e\u093e \u0924\u0915 \u092a\u0939\u0941\u0901\u091a\u0928\u0947 \u0915\u0940 \u0909\u092e\u094d\u092e\u0940\u0926 \u0915\u0930\u0947\u0902\u0964<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f \u092c\u0928\u093e\u092e \u0938\u092e\u092f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0935\u0943\u0926\u094d\u0927\u093f \u0924\u0902\u0924\u094d\u0930 \u0915\u0947 \u0918\u093f\u0938\u093e\u0935 \u0914\u0930 \u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0905\u091a\u093e\u0928\u0915 \u0909\u091b\u093e\u0932 \u0915\u093f\u0938\u0940 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0916\u0930\u093e\u092c\u0940 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917, \u0932\u093f\u0902\u0915) \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0928\u093e\u092e \u0938\u092e\u092f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u0915\u092e\u0940 \u0938\u093e\u092e\u093e\u0928\u094d\u092f (\u092c\u0941\u0922\u093c\u093e\u092a\u093e)<\/li>\n\n\n\n<li>\u0924\u0947\u091c\u093c \u0915\u092e\u0940 \u0928\u092e\u0940, \u0938\u0902\u0926\u0942\u0937\u0923, \u0915\u094d\u0937\u0924\u093f \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093e\u0924\u094d\u092e\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u093e \u0938\u092e\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong>&nbsp;\u091c\u092c \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948 \u0915\u093f \u0905\u0917\u0932\u0947 6\u201312 \u092e\u0939\u0940\u0928\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u091c\u093e\u090f\u0917\u093e\u0964<\/li>\n\n\n\n<li><strong>\u092f\u0902\u0924\u094d\u0930\u0923\u093e \u092e\u0947\u0902 \u0935\u094d\u092f\u093e\u092a\u0915 \u0938\u0941\u0927\u093e\u0930 \u0915\u0940 \u092f\u094b\u091c\u0928\u093e<\/strong>&nbsp;\u091c\u092c \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u00b110% \u0938\u0940\u092e\u093e \u0915\u0947 \u0915\u0930\u0940\u092c \u092a\u0939\u0941\u0901\u091a\u0924\u0940 \u0939\u0948<\/li>\n\n\n\n<li><strong>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0940 \u091c\u093e\u0902\u091a \u0915\u0930\u0947\u0902<\/strong>&nbsp;\u092f\u0926\u093f \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092c\u0947\u0921\u093c\u0947 \u0915\u0947 \u0914\u0938\u0924 \u0938\u0947 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947 \u0918\u091f \u0930\u0939\u093e \u0939\u0948<\/li>\n<\/ul>\n\n\n\n<p><strong>\u092b\u094d\u0932\u0940\u091f \u091f\u094d\u0930\u0947\u0902\u0921\u093f\u0902\u0917<\/strong>:<\/p>\n\n\n\n<p>\u092f\u0926\u093f \u0906\u092a \u0915\u0908 \u0938\u092e\u093e\u0928 VCBs \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902, \u0924\u094b \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0915\u094c\u0928 \u0938\u0940 \u0907\u0915\u093e\u0907\u092f\u093e\u0901 \u0924\u0947\u091c\u093c\u0940 \u0938\u0947 \u0916\u0930\u093e\u092c \u0939\u094b\u0924\u0940 \u0939\u0948\u0902? (\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u092f\u093e \u0921\u094d\u092f\u0942\u091f\u0940 \u0938\u0902\u092c\u0902\u0927\u0940 \u092d\u093f\u0928\u094d\u0928\u0924\u093e\u0913\u0902 \u0915\u094b \u0907\u0902\u0917\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948)<\/li>\n\n\n\n<li>\u0915\u094d\u092f\u093e \u0915\u093f\u0938\u0940 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u092c\u0948\u091a \u0915\u0940 \u0938\u092d\u0940 \u0907\u0915\u093e\u0907\u092f\u094b\u0902 \u092e\u0947\u0902 \u0938\u092e\u093e\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0906 \u0930\u0939\u0940 \u0939\u0948\u0902? (\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0921\u093f\u091c\u093c\u093e\u0907\u0928\/\u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0937)<\/li>\n\n\n\n<li>\u0915\u094d\u092f\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094d\u0937\u0930\u0923 \u0926\u0930 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948? (\u0905\u0902\u0924\u0930\u093e\u0932 \u0915\u093e \u0905\u0928\u0941\u0915\u0942\u0932\u0928)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-problems-and-troubleshooting\">\u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0914\u0930 \u0938\u092e\u093e\u0927\u093e\u0928<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0932\u0915\u094d\u0937\u0923<\/th><th>\u0928\u093f\u0926\u093e\u0928\u093e\u0924\u094d\u092e\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/th><th>\u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0915\u093e\u0930\u0923<\/th><th>\u0909\u092a\u091a\u093e\u0930<\/th><\/tr><\/thead><tbody><tr><td><strong>\u092b\u093f\u0938\u0932\u0947\u0917\u093e \u0928\u0939\u0940\u0902<\/strong><\/td><td>\u091f\u094d\u0930\u093f\u092a \u0915\u0949\u0907\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u093e\u0901\u091a\u0947\u0902<\/td><td>\u0905\u0902\u0921\u0930-\u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0916\u0941\u0932\u093e \u0938\u0930\u094d\u0915\u093f\u091f<\/td><td>\u0938\u0939\u0940 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0915\u0930\u0947\u0902, \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0915\u0940 \u092e\u0930\u092e\u094d\u092e\u0924 \u0915\u0930\u0947\u0902\u0964<\/td><\/tr><tr><td><\/td><td>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091c\u0941\u0921\u093c\u093e\u0935 \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902<\/td><td>\u092c\u093e\u0907\u0902\u0921\u093f\u0902\u0917, \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091c\u093e\u092e<\/td><td>\u0928\u093f:\u0936\u0941\u0932\u094d\u0915 \u0924\u0902\u0924\u094d\u0930, \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0930\u0947\u0902<\/td><\/tr><tr><td><\/td><td>\u090f\u0902\u091f\u0940-\u092a\u0902\u092a\u093f\u0902\u0917 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902<\/td><td>\u0917\u0932\u0924 \u0932\u0949\u0915\u0906\u0909\u091f<\/td><td>\u0930\u093f\u0932\u0947 \u0915\u094b \u0930\u0940\u0938\u0947\u091f \u0915\u0930\u0947\u0902, \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0940 \u091c\u093e\u0901\u091a \u0915\u0930\u0947\u0902\u0964<\/td><\/tr><tr><td><strong>\u092c\u0902\u0926 \u0928\u0939\u0940\u0902 \u0939\u094b\u0917\u093e<\/strong><\/td><td>\u0915\u094d\u0932\u094b\u091c\u093c \u0915\u0949\u0907\u0932 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091c\u093e\u0901\u091a\u0947\u0902<\/td><td>\u0905\u0902\u0921\u0930-\u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u0915\u0949\u0907\u0932 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e<\/td><td>\u0938\u0939\u0940 \u0906\u092a\u0942\u0930\u094d\u0924\u093f \u0915\u0930\u0947\u0902, \u0915\u0949\u0907\u0932 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td><\/td><td>\u091a\u0947\u0915 \u092e\u0948\u0915\u0947\u0928\u093f\u091c\u094d\u092e \u0936\u0941\u0932\u094d\u0915<\/td><td>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0921\u093f\u0938\u094d\u091a\u093e\u0930\u094d\u091c \u0939\u094b \u0917\u092f\u093e, \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u0932\u093f\u0915 \u0926\u092c\u093e\u0935 \u0915\u092e<\/td><td>\u091a\u093e\u0930\u094d\u091c \u0924\u0902\u0924\u094d\u0930<\/td><\/tr><tr><td><\/td><td>\u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/td><td>\u0928\u091c\u093c\u0926\u0940\u0915\u0940 \u0930\u094b\u0915\u0928\u0947 \u0935\u093e\u0932\u093e \u0907\u0902\u091f\u0930\u0932\u0949\u0915<\/td><td>\u0907\u0902\u091f\u0930\u0932\u0949\u0915 \u0938\u094d\u0925\u093f\u0924\u093f \u091c\u093e\u0902\u091a\u0947\u0902, \u0916\u0930\u093e\u092c\u0940 \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902<\/td><\/tr><tr><td><strong>\u0927\u0940\u092e\u0940 \u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f<\/strong><\/td><td>\u0938\u092e\u092f \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/td><td>\u0938\u094d\u0928\u0947\u0939\u0928 \u0938\u0942\u0916 \u0917\u092f\u093e, \u0935\u0938\u0902\u0924 \u0925\u0915\u093e\u0928<\/td><td>\u092a\u0941\u0928\u0903 \u091a\u093f\u0915\u0928\u093e\u0908 \u0915\u0930\u0947\u0902, \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td><\/td><td>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u092c\u0932 \u092e\u093e\u092a\u0947\u0902<\/td><td>\u0915\u092e\u091c\u094b\u0930 \u0935\u0938\u0902\u0924<\/td><td>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0905\u0938\u0947\u0902\u092c\u0932\u0940 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u0909\u091b\u093e\u0932<\/strong><\/td><td>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u091f\u094d\u0930\u0947\u0938 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/td><td>\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u0940 \u0917\u0924\u093f \u0905\u0924\u094d\u092f\u0927\u093f\u0915, \u0921\u0948\u092e\u094d\u092a\u093f\u0902\u0917 \u0916\u094b \u0917\u0908<\/td><td>\u092c\u0902\u0926 \u0939\u094b\u0928\u0947 \u0915\u0940 \u0917\u0924\u093f \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902, \u0921\u0948\u092e\u094d\u092a\u0930 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td><strong>\u0909\u091a\u094d\u091a \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong><\/td><td>\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f<\/td><td>\u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923, \u0935\u093f\u0938\u0902\u0930\u0947\u0916\u0923<\/td><td>\u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902 (\u092f\u0926\u093f \u092a\u0939\u0941\u0901\u091a \u092f\u094b\u0917\u094d\u092f \u0939\u094b), \u0938\u0940\u092e\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><tr><td><strong>\u0928\u093f\u092e\u094d\u0928 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong><\/td><td>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u0906\u0930\u094d\u0926\u094d\u0930\u0924\u093e \u092e\u0947\u0902 \u092e\u093e\u092a\u0947\u0902<\/td><td>\u0928\u092e\u0940<\/td><td>\u092a\u0948\u0928\u0932 \u0915\u094b \u0938\u0941\u0916\u093e\u090f\u0901, \u0938\u0940\u0932\u093f\u0902\u0917 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0947\u0902<\/td><\/tr><tr><td><\/td><td>\u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923<\/td><td>\u0926\u0942\u0937\u0923, \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917<\/td><td>\u0907\u0902\u0938\u0941\u0932\u0947\u091f\u0930\u094b\u0902 \u0915\u094b \u0938\u093e\u092b\u093c \u0915\u0930\u0947\u0902, \u092f\u0926\u093f \u0909\u0928 \u092a\u0930 \u0927\u092c\u094d\u092c\u0947 \u0939\u094b\u0902 \u0924\u094b \u092c\u0926\u0932\u0947\u0902\u0964<\/td><\/tr><tr><td><strong>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093f\u092b\u0932<\/strong><\/td><td>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/td><td>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u093e \u0915\u094d\u0937\u0930\u0923<\/td><td>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u092c\u0926\u0932\u0947\u0902<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"safety-precautions\">\u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u093e\u0935\u0927\u093e\u0928\u093f\u092f\u093e\u0901<\/h2>\n\n\n\n<p>\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0947\u0902 \u0938\u0902\u091a\u093f\u0924 \u090a\u0930\u094d\u091c\u093e, \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0916\u0924\u0930\u0947 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u0915\u093e\u092e \u0936\u0941\u0930\u0942 \u0915\u0930\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0905\u0932\u0917\u093e\u0935 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong>\u0938\u092d\u0940 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u092a\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u093f\u091f\u0947\u0915\u094d\u091f\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0932\u0949\u0915 \u0906\u0909\u091f\/\u091f\u0948\u0917 \u0906\u0909\u091f<\/strong>\u0915\u093e\u092e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u090a\u0930\u094d\u091c\u093e \u0938\u0915\u094d\u0930\u093f\u092f\u0923 \u0915\u094b \u0930\u094b\u0915\u0947\u0902<\/li>\n\n\n\n<li><strong>\u0938\u0902\u0917\u094d\u0930\u0939\u093f\u0924 \u090a\u0930\u094d\u091c\u093e \u0915\u093e \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928<\/strong>: \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938, \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930, \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u0932\u093f\u0915 \u090f\u0915\u094d\u092f\u0942\u092e\u0941\u0932\u0947\u091f\u0930<\/li>\n\n\n\n<li><strong>\u0906\u0930\u094d\u0915 \u092b\u094d\u0932\u0948\u0936 \u092a\u0940\u092a\u0940\u0908<\/strong>\u092c\u093f\u091c\u0932\u0940 \u0930\u0939\u093f\u0924 \u0915\u093e\u0930\u094d\u092f \u0915\u0947 \u0932\u093f\u090f \u092d\u0940 \u092a\u0940\u092a\u0940\u0908 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948 (\u0907\u0902\u0921\u0915\u094d\u0936\u0928, \u0938\u0902\u091a\u093f\u0924 \u090a\u0930\u094d\u091c\u093e \u0915\u0947 \u091c\u094b\u0916\u093f\u092e)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>\u0915\u0947\u0935\u0932 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u094b \u0939\u0940 NFPA 70E \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0915\u094d\u0932\u0940\u092f\u0930\u0947\u0902\u0938 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n\n\n\n<li><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong>\u092c\u094d\u0930\u0947\u0915\u0930 \u0915\u093e\u092b\u0940 \u091c\u093c\u094b\u0930 \u0938\u0947 \u092c\u0902\u0926\/\u091f\u094d\u0930\u093f\u092a \u0939\u094b \u0938\u0915\u0924\u093e \u0939\u0948\u2014\u091a\u0932\u0924\u0947 \u0939\u0941\u090f \u0939\u093f\u0938\u094d\u0938\u094b\u0902 \u0938\u0947 \u0926\u0942\u0930 \u0930\u0939\u0947\u0902\u0964<\/li>\n\n\n\n<li><strong>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>: \u0909\u091a\u094d\u091a \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0927\u093e\u0930\u093e\u090f\u0901 (100\u2013200 A) \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u092c\u0932 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u092c\u093e\u0926<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong>: \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0915\u0908 \u092c\u093e\u0930 \u091f\u094d\u0930\u093f\u092a \u0915\u0930\u0947\u0902 \u0914\u0930 \u092c\u0902\u0926 \u0915\u0930\u0947\u0902<\/li>\n\n\n\n<li><strong>\u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong>: \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0938\u0947\u091f\u093f\u0902\u0917\u094d\u0938, \u0907\u0902\u091f\u0930\u0932\u0949\u0915\u094d\u0938<\/li>\n\n\n\n<li><strong>\u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c<\/strong>\u0938\u0947\u0935\u093e \u092e\u0947\u0902 \u0932\u094c\u091f\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u093e \u092a\u0942\u0930\u093e \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u092d\u0930\u0947\u0902\u0964<\/li>\n<\/ol>\n\n\n\n<p>\u0935\u093f\u0936\u093f\u0937\u094d\u091f VCB \u092a\u094d\u0930\u0915\u093e\u0930\u094b\u0902 \u092a\u0930 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0930\u0916\u0930\u0916\u093e\u0935 \u0917\u093e\u0907\u0921 \u0914\u0930 \u0907\u0938 \u092a\u0930\u093e\u092e\u0930\u094d\u0936 \u0915\u0930\u0947\u0902\u0964&nbsp;<a href=\"https:\/\/xbrele.com\/hi\/drawout-vcb-racking-safety-shutters-alignment-checks\/\">\u0921\u094d\u0930\u093e-\u0906\u0909\u091f VCB \u0930\u0948\u0915\u093f\u0902\u0917 \u0914\u0930 \u0938\u0902\u0930\u0947\u0916\u0923 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u092e\u0941\u0916\u094d\u092f \u092c\u093e\u0924\u0947\u0902<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0935\u0940\u0938\u0940\u092c\u0940 \u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u0941\u0930\u094d\u0932\u092d \u0932\u0947\u0915\u093f\u0928 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0926\u094b\u0937 \u0930\u0941\u0915\u093e\u0935\u091f \u0921\u094d\u092f\u0942\u091f\u0940 \u0915\u0947 \u0932\u093f\u090f \u0924\u0924\u094d\u092a\u0930\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0947\u0924\u093e \u0939\u0948\u2014\u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0926\u0943\u0936\u094d\u092f \u091c\u093e\u0902\u091a \u0914\u0930 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\/\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a\u0928 (&lt;150 \u03bc\u03a9 \u0938\u0940\u092e\u093e) \u0914\u0930 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0938\u094d\u092a\u0947\u0938\u093f\u092b\u093f\u0915\u0947\u0936\u0928 \u0915\u0947 \u00b110% \u0915\u0947 \u092d\u0940\u0924\u0930) \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0939\u0948\u0902 \u091c\u094b \u092e\u0939\u0940\u0928\u094b\u0902 \u092a\u0939\u0932\u0947 \u0939\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u0940 \u092d\u0935\u093f\u0937\u094d\u092f\u0935\u093e\u0923\u0940 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u092e\u0947\u0902 \u0917\u093f\u0930\u093e\u0935\u091f \u0938\u0940\u0927\u0947 \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u093f\u0902\u0917 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u2014\u0916\u0941\u0932\u0928\u0947 \u0915\u093e \u0938\u092e\u092f 10% \u0927\u0940\u092e\u093e \u0939\u094b\u0928\u0947 \u092a\u0930 \u0906\u0930\u094d\u0915 \u0935\u093f\u0932\u0941\u092a\u094d\u0924\u093f \u0915\u0940 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u092e\u0947\u0902 \u0905\u0938\u0902\u0917\u0924\u0924\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 (\u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u092f\u093e \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 1000V \u092e\u0947\u0917\u0930) \u0926\u094b\u0937 \u0905\u0935\u0930\u094b\u0927\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0947 \u092a\u0939\u0932\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u091f\u094d\u0930\u0947\u0902\u0921 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u091a\u094d\u091a\u0947 \u092e\u093e\u092a\u094b\u0902 \u0915\u094b \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0947\u0902 \u092c\u0926\u0932 \u0926\u0947\u0924\u093e \u0939\u0948\u2014\u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0935\u0943\u0926\u094d\u0927\u093f \u0915\u093e \u0905\u0928\u0941\u092e\u093e\u0928 \u0932\u0917\u093e\u0915\u0930 6\u201312 \u092e\u0939\u0940\u0928\u0947 \u092a\u0939\u0932\u0947 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0915\u093e \u092a\u0942\u0930\u094d\u0935\u093e\u0928\u0941\u092e\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n\n\n\n<li>\u0911\u092a\u0930\u0947\u0936\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0902\u0924\u0930\u093e\u0932 (\u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 2,000 \u0911\u092a\u094d\u0938) \u0905\u0915\u094d\u0938\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u091c\u0948\u0938\u0947 \u091c\u0928\u0930\u0947\u091f\u0930 \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092f\u093e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0938\u094d\u0915\u0940\u092e\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u092f-\u0906\u0927\u093e\u0930\u093f\u0924 \u0905\u0928\u0941\u0938\u0942\u091a\u093f\u092f\u094b\u0902 \u0915\u093e \u092a\u0942\u0930\u0915 \u0939\u0948\u0902\u0964<\/li>\n\n\n\n<li>\u092b\u0940\u0932\u094d\u0921 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u091f\u0947\u092e\u094d\u092a\u0932\u0947\u091f \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u092c\u0947\u0921\u093c\u0947 \u0915\u0947 \u0930\u0941\u091d\u093e\u0928 \u0914\u0930 \u0905\u0928\u0941\u0915\u0942\u0932\u0928 \u0915\u094b \u0938\u0915\u094d\u0937\u092e \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u2014\u0938\u092e\u093e\u0928 VCBs \u092e\u0947\u0902 \u0938\u0941\u0938\u0902\u0917\u0924 \u0921\u0947\u091f\u093e \u0938\u0902\u0917\u094d\u0930\u0939 \u090f\u0915\u0932-\u0907\u0915\u093e\u0908 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u092e\u0947\u0902 \u0905\u0926\u0943\u0936\u094d\u092f \u092a\u0948\u091f\u0930\u094d\u0928 \u092a\u094d\u0930\u0915\u091f \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u0926\u0930\u094d\u092d:<\/strong>&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">\u0906\u0908\u0908\u0938\u0940 62271-106<\/a>&nbsp;\u2014 \u090f\u0938\u0940 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f IEC 62271-106 \u092e\u093e\u0928\u0915<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 1: \u092e\u0941\u091d\u0947 VCB \u092a\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/strong><br>A: \u092e\u093e\u0928\u0915 \u0935\u093f\u0924\u0930\u0923 VCBs \u0915\u0947 \u0932\u093f\u090f \u0935\u093e\u0930\u094d\u0937\u093f\u0915, \u091c\u0928\u0930\u0947\u091f\u0930 \u092c\u094d\u0930\u0947\u0915\u0930\u094d\u0938 \u092f\u093e \u092c\u093e\u0930-\u092c\u093e\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 (&gt;500 \u0911\u092a\u094d\u0938\/\u0935\u0930\u094d\u0937) \u0935\u093e\u0932\u0940 \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u092f\u094b\u091c\u0928\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0930\u094d\u0927\u0935\u093e\u0930\u094d\u0937\u093f\u0915\u0964 \u0915\u093f\u0938\u0940 \u092d\u0940 \u092b\u0949\u0932\u094d\u091f \u0905\u0935\u0930\u094b\u0927 \u0915\u0947 \u092c\u093e\u0926 \u0939\u092e\u0947\u0936\u093e 50% \u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902, \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u092b\u0949\u0932\u094d\u091f \u0906\u0930\u094d\u0915 \u090a\u0930\u094d\u091c\u093e \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0930\u0923 \u0915\u094b \u0924\u0947\u091c \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 2: VCB \u0930\u0916\u0930\u0916\u093e\u0935 \u0914\u0930 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u092e\u0947\u0902 \u0915\u094d\u092f\u093e \u0905\u0902\u0924\u0930 \u0939\u0948?<\/strong><br>A: VCBs \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0924\u0924\u094d\u092a\u0930\u0924\u093e (\u0938\u092e\u092f \u0938\u091f\u0940\u0915\u0924\u093e, \u0935\u093f\u0918\u091f\u0928 \u0915\u094d\u0937\u092e\u0924\u093e) \u092a\u0930 \u091c\u094b\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c\u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u0939\u0928\u0936\u0915\u094d\u0924\u093f (\u0938\u0902\u091a\u092f\u0940 \u0918\u093f\u0938\u093e\u0935 \u091f\u094d\u0930\u0948\u0915\u093f\u0902\u0917) \u092a\u0930\u0964 VCBs \u0915\u094b \u0905\u0927\u093f\u0915 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0938\u092e\u092f\/\u0917\u0924\u093f \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948 \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0926\u094b\u0937 \u0935\u093f\u0918\u091f\u0928 \u0938\u091f\u0940\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0917\u0924\u093f \u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u0930\u0924\u093e \u0939\u0948; \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u0930\u094d\u0938 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0906\u0930\u094d\u0915 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0947 \u0930\u0941\u091d\u093e\u0928 \u092a\u0930 \u0905\u0927\u093f\u0915 \u0927\u094d\u092f\u093e\u0928 \u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>\u092a\u094d\u0930\u0936\u094d\u0928 3: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0909\u092a\u0915\u0930\u0923 \u0915\u0947 \u092c\u093f\u0928\u093e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0905\u0916\u0902\u0921\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/strong><br>A: \u0939\u093e\u0901\u2014\u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0938\u094d\u0915\u094d\u0930\u0940\u0928\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0916\u0941\u0932\u0947 \u0938\u0902\u092a\u0930\u094d\u0915\u094b\u0902 \u092a\u0930 1,000\u20132,500 V \u092e\u0947\u0917\u0930 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964  \u0905\u091a\u094d\u091b\u0940 \u0935\u0948\u0915\u094d\u092f\u0942\u092e &gt;100 M\u03a9 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0926\u093f\u0916\u093e\u0924\u0940 \u0939\u0948\u0964  \u092f\u0939 \u0935\u093f\u0927\u093f \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0915\u092e \u0928\u093f\u0930\u094d\u0923\u093e\u092f\u0915 \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0928\u093f\u092f\u092e\u093f\u0924 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u091c\u093e\u0902\u091a \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0939\u0948\u0964  \u0939\u0930 3\u20135 \u0935\u0930\u094d\u0937\u094b\u0902 \u092e\u0947\u0902 \u092f\u093e \u092f\u0926\u093f \u092e\u0947\u0917\u0930 \u0915\u0947 \u092a\u0930\u093f\u0923\u093e\u092e \u0938\u0902\u0926\u0947\u0939\u093e\u0938\u094d\u092a\u0926 \u0939\u094b\u0902 \u0924\u094b \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q4: \u0938\u092e\u092f \u0915\u0947 \u0938\u093e\u0925 \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 \u092c\u093e\u0939\u0930 \u0915\u094d\u092f\u094b\u0902 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948?<\/strong><br>A: \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0915\u093e\u0930\u0923: (1) \u0938\u094d\u0928\u0947\u0939\u0928 \u0915\u093e \u0909\u092e\u094d\u0930 \u092c\u0922\u093c\u0928\u093e\u2014\u0917\u094d\u0930\u0940\u0938 \u0938\u0942\u0916 \u091c\u093e\u0924\u093e \u0939\u0948 \u092f\u093e \u0924\u0930\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0918\u0930\u094d\u0937\u0923 \u092c\u0922\u093c\u0924\u093e \u0939\u0948; (2) \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0925\u0915\u093e\u0928\u2014\u0939\u091c\u093e\u0930\u094b\u0902 \u0938\u0902\u091a\u093e\u0932\u0928\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917\u094d\u0938 \u092e\u0947\u0902 \u0924\u0928\u093e\u0935 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948; (3) \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0918\u093f\u0938\u093e\u0935\u2014\u0918\u0941\u092e\u093e\u0935\u0926\u093e\u0930 \u091b\u0947\u0926 \u0932\u092e\u094d\u092c\u0947 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u0932\u093f\u0902\u0915 \u092a\u093f\u0928 \u0918\u093f\u0938 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0922\u0940\u0932\u093e\u092a\u0928 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948; (4) \u0932\u0945\u091a \u0918\u093f\u0938\u093e\u0935\u2014\u0938\u0902\u0932\u0917\u094d\u0928\u0924\u093e \u0915\u093e \u0938\u092e\u092f \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0927\u0940\u0930\u0947-\u0927\u0940\u0930\u0947 \u092c\u0926\u0932\u093e\u0935 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0939\u0948; \u0905\u091a\u093e\u0928\u0915 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0918\u091f\u0915 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n\n\n\n<p><strong>Q5: \u092e\u0941\u091d\u0947 \u0915\u0948\u0938\u0947 \u092a\u0924\u093e \u091a\u0932\u0947\u0917\u093e \u0915\u093f \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u094d\u0938 \u0915\u094b \u0915\u092c \u092c\u0926\u0932\u0928\u093e \u0939\u0948 \u0914\u0930 \u092a\u0942\u0930\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094b \u0915\u092c \u092c\u0926\u0932\u0928\u093e \u0939\u0948?<\/strong><br>A: \u092f\u0926\u093f \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0938\u0947\u0935\u093e \u0938\u0940\u092e\u093e (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 150 \u03bc\u03a9) \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b \u091c\u093e\u090f \u092f\u093e \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u091f\u0942\u091f \u091c\u093e\u090f, \u0924\u094b \u092a\u0942\u0930\u0947 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 \u0915\u094b \u092c\u0926\u0932\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u2014\u0938\u0902\u092a\u0930\u094d\u0915 \u0914\u0930 \u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0906\u0935\u0930\u0923 \u090f\u0915 \u0938\u0940\u0932\u092c\u0902\u0926 \u0907\u0915\u093e\u0908 \u0939\u0948\u0902 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u092b\u0940\u0932\u094d\u0921 \u092e\u0947\u0902 \u092e\u0930\u092e\u094d\u092e\u0924 \u0928\u0939\u0940\u0902 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e\u0964   \u0932\u093e\u0917\u0924: \u0935\u094b\u0932\u094d\u091f\u0947\u091c\/\u0915\u0930\u0902\u091f \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f \u0907\u0902\u091f\u0930\u092a\u094d\u091f\u0930 $300\u2013$1,500\u0964   \u092c\u0926\u0932\u0940 \u0915\u093e \u0938\u092e\u092f: \u092a\u094d\u0930\u0924\u093f VCB 2\u20136 \u0918\u0902\u091f\u0947\u0964.<\/p>\n\n\n\n<p><strong>Q6: \u0915\u094d\u092f\u093e \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0914\u0930 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u090f\u0915 \u0939\u0940 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/strong><br>A: \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u091c\u093e\u0902\u091a \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0938\u0947 \u092a\u0930\u093f\u091a\u093f\u0924 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u0947 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0940\u0936\u093f\u092f\u0928 \u0926\u094d\u0935\u093e\u0930\u093e \u0915\u0940 \u091c\u093e \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0909\u092a\u0915\u0930\u0923 (\u092e\u093e\u0907\u0915\u094d\u0930\u094b-\u0913\u0939\u092e\u092e\u0940\u091f\u0930, \u091f\u093e\u0907\u092e\u093f\u0902\u0917 \u090f\u0928\u093e\u0932\u093e\u0907\u091c\u093c\u0930, HV \u091f\u0947\u0938\u094d\u091f \u0938\u0947\u091f) \u0914\u0930 \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u0940 \u0935\u094d\u092f\u093e\u0916\u094d\u092f\u093e \u092e\u0947\u0902 \u092a\u094d\u0930\u0936\u093f\u0915\u094d\u0937\u0923 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u2014\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092f\u0939 \u0938\u092e\u0930\u094d\u092a\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0924\u0915\u0928\u0940\u0936\u093f\u092f\u0928\u094b\u0902 \u092f\u093e \u0905\u0928\u0941\u092c\u0902\u0927\u093f\u0924 \u0935\u093f\u0936\u0947\u0937\u091c\u094d\u091e\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n\n\n\n<p><strong>Q7: \u0926\u094b\u0937 \u0930\u0941\u0915\u093e\u0935\u091f\u0947\u0902 \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932\u094b\u0902 \u0915\u094b \u0915\u0948\u0938\u0947 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902?<\/strong><br>A: \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0926\u094b\u0937 \u0935\u093f\u0930\u093e\u092e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u092a\u0930\u094d\u0915 \u0905\u092a\u0915\u094d\u0937\u092f \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0924\u0928\u093e\u0935 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964  \u0930\u0947\u091f\u0947\u0921 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0927\u093e\u0930\u093e \u0915\u0947 50% \u0938\u0947 \u0905\u0927\u093f\u0915 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0926\u094b\u0937 \u0935\u093f\u0930\u093e\u092e \u0915\u0947 \u092c\u093e\u0926 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0914\u0930 \u0938\u092e\u092f \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0947\u0902\u0964  \u090f\u0915\u093e\u0927\u093f\u0915 \u0926\u094b\u0937 \u0938\u0902\u091a\u093e\u0932\u0928 \u0938\u0947\u0915\u0902\u0921\u094b\u0902 \u092e\u0947\u0902 \u0939\u0940 \u0935\u0930\u094d\u0937\u094b\u0902 \u0915\u0940 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0906\u092f\u0941 \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u2014\u0926\u094b\u0937 \u0907\u0924\u093f\u0939\u093e\u0938 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u092f\u094b\u091c\u0928\u093e \u0915\u094b \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u0930\u0947\u0902, \u0928 \u0915\u093f \u0915\u0947\u0935\u0932 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0940 \u0938\u0902\u0916\u094d\u092f\u093e \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930\u0964.<\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Vacuum circuit breakers fail in predictable ways. Contact erosion from arc energy, timing drift from mechanism wear, insulation degradation from moisture\u2014these deterioration modes announce themselves through measurable indicators months before catastrophic failure. Unlike contactors that switch loads thousands of times annually, VCBs interrupt faults occasionally but must perform flawlessly when called. A single failure [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2538,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2537","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=2537"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2537\/revisions"}],"predecessor-version":[{"id":3552,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/2537\/revisions\/3552"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/2538"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=2537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=2537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=2537"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}