{"id":3679,"date":"2026-04-28T00:00:00","date_gmt":"2026-04-28T00:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3679"},"modified":"2026-06-18T08:22:07","modified_gmt":"2026-06-18T08:22:07","slug":"control-cable-selection-mv-panels","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/control-cable-selection-mv-panels\/","title":{"rendered":"\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u093e \u091a\u092f\u0928: \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917, \u092b\u093e\u092f\u0930 \u0930\u0947\u091f\u093f\u0902\u0917, \u0914\u0930 \u0930\u0942\u091f\u093f\u0902\u0917"},"content":{"rendered":"<h2>\u092a\u0930\u093f\u091a\u092f: \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u0942\u092e\u093f\u0915\u093e<\/h2>\n<p>\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c (MV) \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0905\u0935\u0938\u0902\u0930\u091a\u0928\u093e \u0915\u0940 \u0924\u0902\u0924\u094d\u0930\u093f\u0915\u093e \u0924\u0902\u0924\u094d\u0930 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e, \u092e\u0940\u091f\u0930\u093f\u0902\u0917, \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0914\u0930 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u093e \u0938\u0902\u091a\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u091c\u092c\u0915\u093f \u0938\u093f\u0938\u094d\u091f\u092e \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u093e\u0935\u0930 \u0915\u0947\u092c\u0932 \u0905\u0915\u094d\u0938\u0930 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0927\u094d\u092f\u093e\u0928 \u0906\u0915\u0930\u094d\u0937\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u093e \u091a\u092f\u0928 \u0938\u0940\u0927\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e, \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u090f\u0915 \u0939\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u0940 \u0935\u093f\u092b\u0932\u0924\u093e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092f\u094b\u091c\u0928\u093e\u0913\u0902 \u0915\u094b \u0905\u092a\u094d\u0930\u092d\u093e\u0935\u0940 \u092c\u0928\u093e \u0938\u0915\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0915\u094d\u0937\u0924\u093f \u092f\u093e \u0935\u093f\u0928\u093e\u0936\u0915\u093e\u0930\u0940 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n<p>\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902, \u092c\u093f\u091c\u0932\u0940 \u0938\u0902\u092f\u0902\u0924\u094d\u0930\u094b\u0902 \u0914\u0930 \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928\u094b\u0902 \u092e\u0947\u0902 \u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0940 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0914\u0930 \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u092e\u0947\u0902 \u092a\u0902\u0926\u094d\u0930\u0939 \u0935\u0930\u094d\u0937\u094b\u0902 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0938\u092e\u092f \u092c\u093f\u0924\u093e\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926, \u092e\u0948\u0902\u0928\u0947 \u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0930\u0942\u092a \u0938\u0947 \u0926\u0947\u0916\u093e \u0939\u0948 \u0915\u093f \u0905\u0928\u0941\u091a\u093f\u0924 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091a\u092f\u0928 \u0915\u0948\u0938\u0947 \u092e\u0939\u0940\u0928\u094b\u0902 \u092f\u093e \u0935\u0930\u094d\u0937\u094b\u0902 \u092c\u093e\u0926 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0915\u0947 \u092c\u093e\u0926 \u092d\u0940 \u0916\u0924\u0930\u0928\u093e\u0915 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u092a\u0930\u0947\u0936\u093e\u0928 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u0930\u093f\u0932\u0947 \u091f\u094d\u0930\u093f\u092a, \u0906\u0917 \u0938\u0947 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0915\u0947\u092c\u0932\u094b\u0902 \u0926\u094d\u0935\u093e\u0930\u093e \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f\u094d\u0938 \u0915\u0947 \u092c\u0940\u091a \u0906\u0917 \u0915\u093e \u092a\u094d\u0930\u0938\u093e\u0930, \u0914\u0930 \u0916\u0930\u093e\u092c \u0924\u0930\u0940\u0915\u0947 \u0938\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u091f \u0915\u093f\u090f \u0917\u090f \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0916\u0930\u093e\u092c\u0940\u2014\u092f\u0947 \u0938\u092d\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u090f\u0915 \u0939\u0940 \u092e\u0942\u0932 \u0915\u093e\u0930\u0923 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902: \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u091a\u0930\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u092a\u0930 \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0927\u094d\u092f\u093e\u0928 \u0928 \u0926\u0947\u0928\u093e\u0964.<\/p>\n<p>\u092f\u0939 \u0935\u094d\u092f\u093e\u092a\u0915 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e 1kV \u0938\u0947 52kV \u0924\u0915 \u0930\u0947\u091f\u0947\u0921 MV \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091a\u092f\u0928 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0935\u093f\u091a\u093e\u0930\u094b\u0902 \u0915\u094b \u0938\u0902\u092c\u094b\u0927\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901, \u0905\u0917\u094d\u0928\u093f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0930\u0947\u091f\u093f\u0902\u0917, \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u0928 \u0915\u0947 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0905\u092d\u094d\u092f\u093e\u0938, \u0914\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0924\u0915\u0928\u0940\u0915\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902, \u091c\u094b \u0926\u0940\u0930\u094d\u0918\u0915\u093e\u0932\u093f\u0915 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n<h2>\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0924\u094d\u0935\u0930\u093f\u0924 \u091a\u092f\u0928 \u092e\u0948\u091f\u094d\u0930\u093f\u0915\u094d\u0938<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0938\u0930\u094d\u0915\u093f\u091f \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/th>\n<th>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u0947\u092c\u0932 \u0938\u0902\u0930\u091a\u0928\u093e<\/th>\n<th>\u092e\u0941\u0916\u094d\u092f \u090f\u0938\u0908\u0913\/\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CT \u0914\u0930 VT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u092a\u0930\u093f\u092a\u0925<\/td>\n<td>\u092a\u091f\u094d\u091f\u0947\u0926\u093e\u0930 \u0924\u093e\u0902\u092c\u093e, \u0938\u092e\u0917\u094d\u0930 \u092c\u0941\u0928\u0940 \u0939\u0941\u0908 \u0922\u093e\u0932, \u0938\u094d\u092a\u0937\u094d\u091f \u0930\u0942\u092a \u0938\u0947 \u092a\u0939\u091a\u093e\u0928\u0940 \u0917\u0908 \u0915\u094b\u0930\u0947\u0902<\/td>\n<td>\u092d\u093e\u0930 \u0938\u091f\u0940\u0915\u0924\u093e, \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0914\u0930 \u0936\u0940\u0932\u094d\u0921 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0947\u0902\u0964.<\/td>\n<\/tr>\n<tr>\n<td>\u091f\u094d\u0930\u093f\u092a, \u0915\u094d\u0932\u094b\u091c\u093c \u0914\u0930 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u091a\u093e\u0930\u094d\u091c \u0938\u0930\u094d\u0915\u093f\u091f<\/td>\n<td>\u092e\u091c\u092c\u0942\u0924 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u092b\u0947\u0930\u0942\u0932 \u0915\u0947 \u0938\u093e\u0925 2.5 \u092e\u093f\u092e\u0940\u00b2 \u0915\u093e \u0924\u093e\u0930\u092f\u0941\u0915\u094d\u0924 \u0924\u093e\u0902\u092c\u093e<\/td>\n<td>\u0915\u094b\u0907\u0932 \u0907\u0928\u0930\u0936, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u0914\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u091f\u093f\u0915\u093e\u090a\u092a\u0928 \u0915\u0947 \u0932\u093f\u090f \u0906\u0915\u093e\u0930\u0964.<\/td>\n<\/tr>\n<tr>\n<td>\u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u0902\u0915\u0947\u0924 \u0914\u0930 \u0938\u0947\u0902\u0938\u0930<\/td>\n<td>\u0928\u093f\u092e\u094d\u0928-\u0936\u094b\u0930 \u0930\u093e\u0909\u091f\u093f\u0902\u0917 \u0915\u0947 \u0938\u093e\u0925 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0930\u0942\u092a \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u091c\u094b\u0921\u093c\u0947 \u092f\u093e \u0924\u093f\u0915\u0921\u093c\u0940<\/td>\n<td>\u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u090f\u0902\u091f\u094d\u0938 \u0914\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0936\u0940\u0932\u094d\u0921\u094d\u0938 \u0915\u094b \u091c\u093e\u0928\u092c\u0942\u091d\u0915\u0930 \u0905\u0932\u0917 \u0930\u0916\u0947\u0902\u0964.<\/td>\n<\/tr>\n<tr>\n<td>\u0908\u0925\u0930\u0928\u0947\u091f, \u0906\u0930\u090f\u0938-485, \u0914\u0930 \u0906\u0908\u0908\u0938\u0940 61850 \u0938\u093f\u0917\u094d\u0928\u0932<\/td>\n<td>\u0908\u090f\u092e\u0938\u0940 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u0947 \u0938\u093e\u0925 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924-\u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u0938\u0902\u091a\u093e\u0930 \u0915\u0947\u092c\u0932<\/td>\n<td>\u0917\u094d\u0932\u0948\u0902\u0921\u094d\u0938, \u092a\u0948\u091a \u092a\u0948\u0928\u0932 \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u0940 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison.webp\" alt=\"\u090f\u092e\u0935\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092b\u0949\u0907\u0932 \u0936\u0940\u0932\u094d\u0921, \u092c\u094d\u0930\u0947\u0921\u0947\u0921 \u0936\u0940\u0932\u094d\u0921, \u0914\u0930 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u091c\u094b\u0921\u093c\u0940 \u092a\u094d\u0932\u0938 \u0938\u092e\u0917\u094d\u0930 \u0936\u0940\u0932\u094d\u0921 \u0915\u0940 \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928 \u0924\u0941\u0932\u0928\u093e\" class=\"wp-image-3675\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0948\u0928\u0932 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u092f\u0941\u0915\u094d\u0924 \u092b\u0949\u0907\u0932, \u092c\u094d\u0930\u0947\u0921\u093f\u0902\u0917 \u0914\u0930 \u0938\u0902\u092f\u0941\u0915\u094d\u0924 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0935\u093f\u0928\u094d\u092f\u093e\u0938\u094b\u0902 \u0915\u0940 \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928\u0932 \u0924\u0941\u0932\u0928\u093e\u0964.<\/figcaption><\/figure>\n<h2>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0935\u0930\u094d\u0917\u0940\u0915\u0930\u0923 \u0914\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0940 \u0938\u092e\u091d<\/h2>\n<h3>\u0938\u0902\u0915\u0947\u0924 \u092a\u094d\u0930\u0915\u093e\u0930 \u0914\u0930 \u0915\u0947\u092c\u0932 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n<p>\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u0938\u093f\u0917\u094d\u0928\u0932 \u0932\u0947 \u091c\u093e\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0928\u092e\u0947\u0902 \u0938\u0947 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0915\u0947\u092c\u0932 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0901 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902:<\/p>\n<p><strong>\u0928\u093f\u092e\u094d\u0928-\u0938\u094d\u0924\u0930\u0940\u092f \u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u0902\u0915\u0947\u0924<\/strong> (4\u201320 mA \u0915\u0930\u0902\u091f \u0932\u0942\u092a, RTD \u0938\u0930\u094d\u0915\u093f\u091f, \u0925\u0930\u094d\u092e\u094b\u0915\u092a\u0932 \u0906\u0909\u091f\u092a\u0941\u091f) \u0909\u091a\u094d\u091a \u0936\u094b\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u094d\u0937\u092e\u0924\u093e \u0914\u0930 \u0938\u094d\u0925\u093f\u0930 \u091a\u093e\u0932\u0915 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u092f\u0947 \u0938\u0930\u094d\u0915\u093f\u091f \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0915\u0930\u0902\u091f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930, \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930, \u0924\u093e\u092a\u092e\u093e\u0928 \u0938\u0947\u0902\u0938\u0930 \u0914\u0930 \u0926\u092c\u093e\u0935 \u091f\u094d\u0930\u093e\u0902\u0938\u092e\u0940\u091f\u0930 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0914\u0930 SCADA \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0947 \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0921\u093f\u091c\u093f\u091f\u0932 \u0938\u0902\u0915\u0947\u0924<\/strong> (\u0930\u093f\u0932\u0947 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f\u094d\u0938, \u0938\u0939\u093e\u092f\u0915 \u0938\u094d\u0935\u093f\u091a, \u0938\u094d\u0925\u093f\u0924\u093f \u0938\u0902\u0915\u0947\u0924\u0915) \u0909\u091a\u094d\u091a \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930 (24\u2013125VDC \u092f\u093e 110\u2013240VAC) \u092a\u0930 \u0905\u0927\u093f\u0915 \u0936\u094b\u0930 \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0915\u0947 \u0938\u093e\u0925 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f, 100 \u092e\u0940\u091f\u0930 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0932\u0902\u092c\u0940 \u0926\u0942\u0930\u0940 \u0915\u0947 \u0932\u093f\u090f \u0915\u0947\u092c\u0932 \u0915\u094d\u0937\u092e\u0924\u093e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948, \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0938\u0949\u0932\u093f\u0921-\u0938\u094d\u091f\u0947\u091f \u0930\u093f\u0932\u0947 \u0907\u0928\u092a\u0941\u091f\u094d\u0938 \u0915\u0947 \u0938\u093e\u0925\u0964.<\/p>\n<p><strong>\u0938\u0902\u091a\u093e\u0930 \u092a\u0930\u093f\u092a\u0925<\/strong> (\u0908\u0925\u0930\u0928\u0947\u091f, \u0938\u0940\u0930\u093f\u092f\u0932 RS-485, IEC 61850 GOOSE \u0938\u0902\u0926\u0947\u0936\u0928) 100 Mbps \u092f\u093e \u0909\u0938\u0938\u0947 \u0905\u0927\u093f\u0915 \u091f\u094d\u0930\u093e\u0902\u0938\u092e\u093f\u0936\u0928 \u0917\u0924\u093f \u092a\u0930 \u0921\u0947\u091f\u093e \u0905\u0916\u0902\u0921\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u093f\u0924 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u0913\u0902 \u0914\u0930 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0935\u093f\u0928\u094d\u092f\u093e\u0938\u094b\u0902 \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<h3>\u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0938\u0902\u092c\u0902\u0927\u0940 \u0935\u093f\u091a\u093e\u0930<\/h3>\n<p>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0915\u093e \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0928\u093e \u0915\u0947\u0935\u0932 \u0938\u0930\u0932 \u0927\u093e\u0930\u093e-\u0935\u093e\u0939\u0915 \u0915\u094d\u0937\u092e\u0924\u093e \u0915\u0940 \u0917\u0923\u0928\u093e\u0913\u0902 \u0938\u0947 \u092a\u0930\u0947 \u0939\u0948\u0964 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0935\u093f\u091a\u093e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902:<\/p>\n<ul>\n<li><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0917\u093f\u0930\u093e\u0935\u091f \u0915\u0940 \u0938\u0940\u092e\u093e\u090f\u0901<\/strong>CT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u094b \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092d\u093e\u0930 \u0938\u091f\u0940\u0915\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f 1% \u0938\u0947 \u0915\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0921\u094d\u0930\u0949\u092a \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964<\/li>\n<li><strong>\u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e<\/strong>CT \u0938\u0947\u0915\u0947\u0902\u0921\u0930\u0940\u091c\u093c \u0915\u094b \u091c\u094b\u0921\u093c\u0928\u0947 \u0935\u093e\u0932\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u0947\u0902 \u0926\u094b\u0937 \u0915\u0940 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0924\u093e\u092a\u0940\u092f \u092a\u094d\u0930\u092d\u093e\u0935\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u0938\u0915\u094d\u0937\u092e \u0939\u094b\u0928\u0940 \u091a\u093e\u0939\u093f\u090f\u0964<\/li>\n<li><strong>\u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0936\u0915\u094d\u0924\u093f<\/strong>\u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0906\u0915\u093e\u0930 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 1.5mm\u00b2 \u092f\u093e 2.5mm\u00b2) \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable.webp\" alt=\"\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f IEC \u0905\u0917\u094d\u0928\u093f \u0930\u0947\u091f\u093f\u0902\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u093e \u0938\u094d\u0924\u0930\u092c\u0926\u094d\u0927 \u0906\u0930\u0947\u0916, \u091c\u093f\u0938\u092e\u0947\u0902 IEC 60332, IEC 61034, IEC 60754, \u0914\u0930 IEC 60331 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964\" class=\"wp-image-3676\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u092c\u0902\u0927\u093f\u0924 \u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0930\u0942\u092e\u094b\u0902 \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u092a\u0930 \u0932\u093e\u0917\u0942 \u0906\u0908\u0908\u0938\u0940 \u0905\u0917\u094d\u0928\u093f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u092e\u093e\u0928\u0915 \u092a\u0926\u093e\u0928\u0941\u0915\u094d\u0930\u092e\u0964.<\/figcaption><\/figure>\n<h2>\u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u094b\u092e\u0948\u0917\u094d\u0928\u0947\u091f\u093f\u0915 \u0938\u0902\u0917\u0924\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901<\/h2>\n<h3>\u090f\u092e\u0935\u0940 \u0935\u093e\u0924\u093e\u0935\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0915\u0947 \u0938\u094d\u0930\u094b\u0924<\/h3>\n<p>\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u090f\u0915 \u091a\u0941\u0928\u094c\u0924\u0940\u092a\u0942\u0930\u094d\u0923 \u0935\u093f\u0926\u094d\u092f\u0941\u0924\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092a\u094d\u0930\u0938\u094d\u0924\u0941\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0938\u094d\u0930\u094b\u0924\u094b\u0902 \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902:<\/p>\n<p><strong>\u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0915\u093f\u092f\u093e<\/strong> \u092f\u0939 \u092a\u093e\u0935\u0930 \u092b\u094d\u0930\u093f\u0915\u094d\u0935\u0947\u0902\u0938\u0940 \u0939\u093e\u0930\u094d\u092e\u094b\u0928\u093f\u0915\u094d\u0938, \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u090f\u0902\u091f\u094d\u0938 \u0914\u0930 \u0926\u094b\u0937 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092a\u094b\u091f\u0947\u0902\u0936\u093f\u092f\u0932 \u0915\u0947 \u0909\u0924\u093e\u0930-\u091a\u0922\u093c\u093e\u0935 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092e\u094b\u091f\u0930 \u0921\u094d\u0930\u093e\u0907\u0935, \u092a\u093e\u0935\u0930 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u0915\u0928\u094d\u0935\u0930\u094d\u091f\u0930\u094d\u0938 \u0914\u0930 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 \u092c\u0948\u0902\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u093e \u0938\u0902\u0935\u0939\u093f\u0924 \u0936\u094b\u0930 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u093e\u091d\u093e \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u092e\u093e\u0930\u094d\u0917\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u092e\u0947\u0902 \u091c\u0941\u0921\u093c \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n<p><strong>\u0935\u093f\u0915\u093f\u0930\u0923 \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a<\/strong> \u092f\u0939 \u0909\u091a\u094d\u091a \u0927\u093e\u0930\u093e\u090f\u0901 \u0935\u0939\u0928 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u092c\u0938 \u092c\u093e\u0930\u094b\u0902, \u0906\u0930\u094d\u0915 \u092b\u094d\u0932\u0948\u0936 \u0918\u091f\u0928\u093e\u0913\u0902, \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0917\u0924\u093f\u0935\u093f\u0927\u093f \u0914\u0930 \u0928\u093f\u0915\u091f\u0935\u0930\u094d\u0924\u0940 \u0930\u0947\u0921\u093f\u092f\u094b \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0938\u094d\u0930\u094b\u0924\u094b\u0902 \u0938\u0947 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u092c\u0938 \u091a\u093e\u0932\u0915\u094b\u0902 \u0915\u0947 \u0906\u0938\u092a\u093e\u0938 \u0915\u0947 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0932\u0942\u092a\u094b\u0902 \u092e\u0947\u0902 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0925\u094d\u0930\u0947\u0936\u094b\u0932\u094d\u0921 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u0938\u094d\u0925\u0948\u0924\u093f\u0915 \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a<\/strong> \u0909\u091a\u094d\u091a-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u091a\u093e\u0932\u0915\u094b\u0902 \u0938\u0947 \u0906\u0938\u0928\u094d\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0924\u0915 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u093f\u0935 \u0930\u0942\u092a \u0938\u0947 \u092f\u0941\u0917\u094d\u092e\u0928, \u091c\u094b \u0917\u0948\u0938-\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 (GIS) \u092e\u0947\u0902 \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0938\u092e\u0938\u094d\u092f\u093e\u0917\u094d\u0930\u0938\u094d\u0924 \u0939\u0948, \u091c\u0939\u093e\u0901 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 SF6-\u092d\u0930\u0947 \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f\u094d\u0938 \u0915\u0947 \u092a\u093e\u0938 \u0938\u0947 \u0917\u0941\u091c\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n<h3>\u0922\u093e\u0932 \u0915\u0947 \u092a\u094d\u0930\u0915\u093e\u0930 \u0914\u0930 \u0909\u0928\u0915\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/h3>\n<p><strong>\u092a\u0928\u094d\u0928\u0940 \u0915\u0940 \u0922\u093e\u0932\u0947\u0902<\/strong> (\u090f\u0932\u094d\u092f\u0942\u092e\u093f\u0928\u093f\u092f\u092e-\u092a\u0949\u0932\u093f\u090f\u0938\u094d\u091f\u0930 \u0932\u0948\u092e\u093f\u0928\u0947\u091f) 100% \u0915\u0935\u0930\u0947\u091c \u0914\u0930 1 \u092e\u0947\u0917\u093e\u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0938\u0947 \u090a\u092a\u0930 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094d\u0937\u0940\u0923\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092a\u0924\u0932\u0940 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u0947\u092c\u0932 \u0915\u0947 \u0935\u094d\u092f\u093e\u0938 \u0915\u094b \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0915\u0930\u0924\u0940 \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0928\u093f\u092e\u094d\u0928-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0905\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u0938\u0940\u092e\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u092b\u0949\u0907\u0932 \u0936\u0940\u0932\u094d\u0921\u094d\u0938 \u0938\u0902\u091a\u093e\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0914\u0930 \u0909\u091a\u094d\u091a-\u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u090f\u0928\u093e\u0932\u0949\u0917 \u0907\u0928\u092a\u0941\u091f\u094d\u0938 \u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0930\u0942\u092a \u0938\u0947 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0917\u0941\u0902\u0925\u0940 \u0939\u0941\u0908 \u0922\u093e\u0932\u0947\u0902<\/strong> (\u091f\u093f\u0928\u094d\u0928\u0947\u0921 \u0915\u0949\u092a\u0930 \u092c\u094d\u0930\u0947\u0921\u0947\u0921, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 85\u201395 dB \u0915\u0935\u0930\u0947\u091c) \u092b\u094b\u0907\u0932 \u0935\u093f\u0915\u0932\u094d\u092a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u092c\u0947\u0939\u0924\u0930 \u0928\u093f\u092e\u094d\u0928-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0914\u0930 \u092c\u0947\u0939\u0924\u0930 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0932\u091a\u0940\u0932\u093e\u092a\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 1 \u092e\u0947\u0917\u093e\u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0938\u0947 \u0928\u0940\u091a\u0947 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u092a\u0930 \u0915\u092e \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0930 \u0907\u092e\u094d\u092a\u0940\u0921\u0947\u0902\u0938 \u0915\u0947 \u0915\u093e\u0930\u0923 \u092c\u094d\u0930\u0947\u0921\u0947\u0921 \u0936\u0940\u0932\u094d\u0921\u094d\u0938 CT\/VT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0914\u0930 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915\u0924\u093e \u0926\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0938\u0902\u092f\u0941\u0915\u094d\u0924 \u0922\u093e\u0932\u0947\u0902<\/strong> (\u092b\u0949\u092f\u0932 \u0914\u0930 \u092c\u094d\u0930\u0947\u0921\u093f\u0902\u0917) \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0938\u094d\u092a\u0947\u0915\u094d\u091f\u094d\u0930\u092e \u092e\u0947\u0902 \u0935\u094d\u092f\u093e\u092a\u0915 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0939\u093e\u0932\u093e\u0902\u0915\u093f \u0905\u0927\u093f\u0915 \u092e\u0939\u0902\u0917\u0940, \u0938\u0902\u092f\u094b\u091c\u0928 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0909\u091a\u094d\u091a \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0935\u093e\u0932\u0947 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0938\u093e\u092c\u093f\u0924 \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u0948\u0938\u0947 \u090f\u092e\u0935\u0940 \u092c\u0938\u094b\u0902 \u0915\u0947 \u092a\u093e\u0938 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0906\u0902\u0936\u093f\u0915 \u0928\u093f\u0930\u094d\u0935\u0939\u0928 \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901\u0964.<\/p>\n<p><strong>\u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0930\u0942\u092a \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u091c\u094b\u0921\u093c\u0947\/\u0924\u094d\u0930\u092f<\/strong> \u090f\u0915 \u0939\u0940 \u0915\u0947\u092c\u0932 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0915\u094d\u0930\u0949\u0938\u091f\u0949\u0915 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948, \u091c\u094b \u090f\u0928\u093e\u0932\u0949\u0917 \u0914\u0930 \u0921\u093f\u091c\u093f\u091f\u0932 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u092e\u093f\u0932\u093e\u0924\u0947 \u0938\u092e\u092f \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0964 \u092f\u0939 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0908 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u094b \u090f\u0915 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0915\u0947\u092c\u0932 \u092e\u093e\u0930\u094d\u0917 \u0938\u093e\u091d\u093e \u0915\u0930\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948, \u0938\u093e\u0925 \u0939\u0940 \u0938\u0902\u0915\u0947\u0924 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u0936\u0940\u0932\u094d\u0921 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0924\u0915\u0928\u0940\u0915\u0947\u0902<\/h3>\n<p>\u0936\u0940\u0932\u094d\u0921 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0915\u093e \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0915\u093e\u092b\u0940 \u092c\u0939\u0938 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0935\u094d\u092f\u093e\u092a\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u092e\u093e\u092a\u094b\u0902 \u0914\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 (IEEE 1143, IEC 62271-1) \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930, \u092e\u0948\u0902 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936 \u0915\u0930\u0924\u093e \u0939\u0942\u0901:<\/p>\n<p><strong>\u090f\u0915\u0932-\u092c\u093f\u0902\u0926\u0941 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917<\/strong> \u092a\u0948\u0928\u0932 \u0915\u0947 \u0938\u093f\u0930\u0947 \u092a\u0930 \u0936\u093f\u0932\u094d\u0921 \u0915\u0902\u0921\u0915\u094d\u091f\u0930\u094b\u0902 \u092e\u0947\u0902 \u092a\u0930\u093f\u0938\u0902\u091a\u093e\u0930\u0940 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948, \u091c\u094b \u0915\u092e \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0935\u093e\u0932\u0947 \u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u0926\u0930\u094d\u0936 \u0939\u0948 \u091c\u0939\u093e\u0901 \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0927\u093e\u0930\u093e\u090f\u0901 \u092e\u093e\u092a \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u093e\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930 \u0938\u0915\u0924\u0940 \u0939\u0948\u0902\u0964 \u0907\u0938 \u0924\u0915\u0928\u0940\u0915 \u0915\u0947 \u0932\u093f\u090f \u0926\u0942\u0930\u0938\u094d\u0925 \u0938\u093f\u0930\u0947 \u092a\u0930 \u0936\u093f\u0932\u094d\u0921 \u0915\u093e \u0909\u091a\u093f\u0924 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/p>\n<p><strong>\u092c\u0939\u0941-\u092c\u093f\u0902\u0926\u0941 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917<\/strong> \u092f\u0939 \u0915\u0908 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u092a\u0930 \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u0924\u0915 \u0928\u093f\u092e\u094d\u0928-\u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u092e\u093e\u0930\u094d\u0917 \u092c\u0928\u093e\u0915\u0930 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0936\u094b\u0930 \u0915\u094b \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0930\u0942\u092a \u0938\u0947 \u0905\u0938\u094d\u0935\u0940\u0915\u093e\u0930 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0909\u0928 \u0921\u093f\u091c\u093f\u091f\u0932 \u0938\u0902\u091a\u093e\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0914\u0930 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u0948 \u091c\u0939\u093e\u0901 \u092c\u093f\u091c\u0932\u0940-\u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0915\u094d\u0937\u0923\u093f\u0915 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0906\u0935\u0947\u0917 \u091a\u093f\u0902\u0924\u093e \u0915\u093e \u0935\u093f\u0937\u092f \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0938\u0902\u0915\u0930 \u092d\u0942-\u0938\u0902\u092a\u0930\u094d\u0915<\/strong> \u0936\u0940\u0932\u094d\u0921\u094d\u0938 \u0915\u094b \u092a\u0948\u0928\u0932 \u0915\u0947 \u0938\u093f\u0930\u0947 \u092a\u0930 \u0938\u0940\u0927\u0947 \u091c\u094b\u0921\u093c\u0924\u093e \u0939\u0948 \u0914\u0930 \u0926\u0942\u0930\u0938\u094d\u0925 \u0938\u093f\u0930\u094b\u0902 \u092a\u0930 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u092c\u093e\u0908\u092a\u093e\u0938 \u0915\u0948\u092a\u0947\u0938\u093f\u091f\u0930 (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 10\u2013100 nF) \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u091c\u094b\u0921\u093c\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0935\u093f\u0928\u094d\u092f\u093e\u0938 \u0928\u093f\u092e\u094d\u0928-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u092a\u0930\u093f\u0938\u0902\u091a\u093e\u0930\u0940 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948, \u0938\u093e\u0925 \u0939\u0940 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948\u0964.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation.webp\" alt=\"\u090f\u092e\u0935\u0940 \u092a\u093e\u0935\u0930, \u090f\u0932\u0935\u0940 \u092a\u093e\u0935\u0930, \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091f\u094d\u0930\u0947\u091c\u093c \u0915\u0947 \u092c\u0940\u091a \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0926\u0942\u0930\u0940 \u0926\u093f\u0916\u093e\u0928\u0947 \u0935\u093e\u0932\u093e \u0915\u0947\u092c\u0932 \u091f\u094d\u0930\u0947 \u0932\u0947\u0906\u0909\u091f \u0906\u0930\u0947\u0916\" class=\"wp-image-3677\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0930\u0942\u092e \u092e\u0947\u0902 \u092a\u093e\u0935\u0930 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925-\u0938\u093e\u0925 \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0915\u0947\u092c\u0932 \u091f\u094d\u0930\u0947 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0926\u0942\u0930\u0940\u0964.<\/figcaption><\/figure>\n<h2>\u0906\u0917 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0914\u0930 \u092e\u093e\u0928\u0915<\/h2>\n<h3>\u0906\u0917 \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u0930\u094d\u0917\u0940\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0938\u092e\u091d\u0928\u093e<\/h3>\n<p>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u0940 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u094d\u0937\u092e\u0924\u093e \u092e\u0947\u0902 \u0915\u0908 \u0917\u0941\u0923 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902, \u091c\u093f\u0928\u092e\u0947\u0902 \u0938\u0947 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u092e\u093e\u0928\u0915\u0940\u0915\u0943\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948:<\/p>\n<p><strong>\u091c\u094d\u0935\u093e\u0932\u093e \u092a\u094d\u0930\u0938\u093e\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong> (IEC 60332 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e) \u0915\u093f\u0938\u0940 \u0915\u0947\u092c\u0932 \u0915\u0940 \u0932\u0902\u092c\u093e\u0908 \u0915\u0947 \u0938\u093e\u0925 \u0906\u0917 \u0915\u0947 \u092b\u0948\u0932\u0928\u0947 \u0915\u0940 \u092a\u094d\u0930\u0935\u0943\u0924\u094d\u0924\u093f \u0915\u094b \u092e\u093e\u092a\u0924\u0940 \u0939\u0948\u0964 IEC 60332-1 \u091b\u094b\u091f\u0947 \u0932\u094c \u0915\u0940 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u092e\u0947\u0902 \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u092c\u0915\u093f IEC 60332-3 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0918\u0928\u0924\u094d\u0935 \u0915\u093e \u092a\u094d\u0930\u0924\u093f\u0928\u093f\u0927\u093f\u0924\u094d\u0935 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0917\u0941\u091a\u094d\u091b\u093f\u0924 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0936\u094d\u0930\u0947\u0923\u0940 A (\u0938\u0930\u094d\u0935\u094b\u091a\u094d\u091a \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928) 3.5 \u092e\u0940\u091f\u0930 \u0915\u0947 \u0928\u092e\u0942\u0928\u0947 \u092a\u0930 \u0932\u094c \u0915\u0947 \u092a\u094d\u0930\u0938\u093e\u0930 \u0915\u094b 2.5 \u092e\u0940\u091f\u0930 \u0938\u0947 \u0915\u092e \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<p><strong>\u0906\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong> (IEC 60331) \u0906\u0917 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u0947\u0902 \u0906\u0928\u0947 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0915\u093e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0915\u0930\u0924\u093e \u0939\u0948\u0964 \u0907\u0938 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u094b \u0909\u0924\u094d\u0924\u0940\u0930\u094d\u0923 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0940 \u0915\u0947\u092c\u0932\u0947\u0902 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0905\u0935\u0927\u093f \u0915\u0947 \u0932\u093f\u090f 750\u00b0C \u0915\u0940 \u0932\u092a\u091f\u094b\u0902 \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u0947\u0902 \u0930\u0939\u0924\u0947 \u0939\u0941\u090f \u092d\u0940 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092a\u0930 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0940 \u0930\u0939\u0924\u0940 \u0939\u0948\u0902\u2014\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 90 \u092f\u093e 120 \u092e\u093f\u0928\u091f\u0964.<\/p>\n<p><strong>\u0927\u0941\u0906\u0901 \u0918\u0928\u0924\u094d\u0935<\/strong> (IEC 61034) \u0915\u0947\u092c\u0932 \u0926\u0939\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0926\u0943\u0936\u094d\u092f\u0924\u093e \u092e\u0947\u0902 \u0915\u092e\u0940 \u0915\u094b \u092e\u093e\u0924\u094d\u0930\u093e\u0924\u094d\u092e\u0915 \u0930\u0942\u092a \u0938\u0947 \u092e\u093e\u092a\u0924\u093e \u0939\u0948\u0964 \u0915\u092e \u0927\u0941\u0906\u0901 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u0947\u092c\u0932 \u0928\u094d\u092f\u0942\u0928\u0924\u092e 60% \u092a\u094d\u0930\u0915\u093e\u0936 \u092a\u093e\u0930\u0917\u092e\u094d\u092f\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0928\u093f\u0915\u093e\u0938\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0905\u0917\u094d\u0928\u093f\u0936\u092e\u0928 \u0915\u093e\u0930\u094d\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0924\u094d\u092f\u0902\u0924 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0939\u0948\u0964.<\/p>\n<p><strong>\u0939\u0948\u0932\u094b\u091c\u0928 \u0915\u0940 \u092e\u093e\u0924\u094d\u0930\u093e \u0914\u0930 \u0905\u092e\u094d\u0932\u0940\u092f \u0917\u0948\u0938 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928<\/strong> (IEC 60754) \u092e\u093e\u0928\u0935 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0915\u094d\u0937\u0930\u0923 \u0926\u094b\u0928\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0932\u094b \u0938\u094d\u092e\u094b\u0915 \u091c\u0940\u0930\u094b \u0939\u0948\u0932\u094b\u091c\u0928 (LSZH) \u0915\u0947\u092c\u0932 \u0917\u0948\u0930-\u0915\u094d\u0937\u0930\u0923\u0915\u093e\u0930\u0940 \u0926\u0939\u0928 \u0909\u0924\u094d\u092a\u093e\u0926 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0905\u092e\u094d\u0932\u0940\u092f \u0917\u0948\u0938\u094b\u0902 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u0941\u0915\u0938\u093e\u0928 \u0938\u0947 \u092c\u091a\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<h3>\u0906\u0935\u0947\u0926\u0928-\u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0905\u0917\u094d\u0928\u093f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n<p>\u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0935\u093e\u0924\u093e\u0935\u0930\u0923\u094b\u0902 \u092e\u0947\u0902 \u0905\u0932\u0917-\u0905\u0932\u0917 \u0905\u0917\u094d\u0928\u093f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0938\u094d\u0924\u0930\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948:<\/p>\n<p><strong>\u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928<\/strong> \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0928\u094d\u092f\u0942\u0928\u0924\u092e IEC 60332-3 \u0936\u094d\u0930\u0947\u0923\u0940 C \u092e\u093e\u0928\u0915 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u0947\u092c\u0932 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u092c\u093e\u0939\u0930\u0940 \u0938\u092e\u093e\u092a\u094d\u0924\u093f \u092c\u093f\u0902\u0926\u0941 \u092a\u094d\u0930\u093e\u0915\u0943\u0924\u093f\u0915 \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0914\u0930 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0926\u0942\u0930\u0940 \u0939\u094b\u0928\u0947 \u092a\u0930 \u092e\u093e\u0928\u0915 \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0938\u0902\u0930\u091a\u0928\u093e\u0913\u0902 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0938\u0941\u0935\u093f\u0927\u093e\u090f\u0901<\/strong> \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u0940 \u0928\u093f\u0915\u093e\u0938\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f LSZH \u0938\u0902\u0930\u091a\u0928\u093e\u0913\u0902 \u0915\u094b \u0924\u0947\u091c\u0940 \u0938\u0947 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u093f\u092f\u093e \u091c\u093e \u0930\u0939\u093e \u0939\u0948\u0964 \u092a\u0947\u091f\u094d\u0930\u094b\u0915\u0947\u092e\u093f\u0915\u0932 \u0938\u0902\u092f\u0902\u0924\u094d\u0930 \u0905\u0915\u094d\u0938\u0930 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u0936\u091f\u0921\u093e\u0909\u0928 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0932\u093f\u090f \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0915 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u094b \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0909\u0924\u094d\u092a\u093e\u0926\u0928 \u0915\u0947\u0902\u0926\u094d\u0930<\/strong> \u092a\u0930\u092e\u093e\u0923\u0941 \u0928\u093f\u092f\u093e\u092e\u0915 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u092f\u093e \u0938\u092e\u0915\u0915\u094d\u0937 \u0925\u0930\u094d\u092e\u0932 \u0938\u0902\u092f\u0902\u0924\u094d\u0930 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0930\u093f\u090f\u0915\u094d\u091f\u0930 \u091f\u094d\u0930\u093f\u092a \u0938\u093f\u0938\u094d\u091f\u092e, \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u092b\u0940\u0921\u0935\u093e\u091f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0914\u0930 \u0905\u0928\u094d\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e-\u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u0947\u092c\u0932\u094b\u0902 (IEC 60331) \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0964.<\/p>\n<p><strong>\u092d\u0942\u092e\u093f\u0917\u0924 \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e\u0928<\/strong> (\u0915\u0947\u092c\u0932 \u0938\u0941\u0930\u0902\u0917\u0947\u0902, \u0924\u0939\u0916\u093e\u0928\u0947) \u0938\u0940\u092e\u093f\u0924 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u0914\u0930 \u0915\u092e \u0935\u0947\u0902\u091f\u093f\u0932\u0947\u0936\u0928 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0936\u094d\u0930\u0947\u0923\u0940 A \u0915\u0940 \u0906\u0917 \u092a\u094d\u0930\u0938\u093e\u0930 \u0930\u0947\u091f\u093f\u0902\u0917 \u0914\u0930 \u0915\u092e \u0927\u0941\u0906\u0901 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928 \u0915\u0940 \u092e\u093e\u0902\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices.webp\" alt=\"\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u093e \u0935\u093f\u0935\u0930\u0923 \u091c\u094b \u0938\u0939\u0940 \u092b\u0947\u0930\u0942\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0914\u0930 \u0928\u0902\u0917\u0947 \u0938\u094d\u091f\u094d\u0930\u0948\u0902\u0921\u0947\u0921 \u0924\u093e\u0930 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948, \u0938\u093e\u0925 \u0939\u0940 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f EMC \u0917\u094d\u0932\u0948\u0902\u0921 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e\" class=\"wp-image-3678\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u092e\u0947\u0902 \u0938\u0939\u0940 \u0914\u0930 \u0917\u0932\u0924 \u0938\u092e\u093e\u092a\u094d\u0924\u093f \u0936\u0930\u094d\u0924\u0947\u0902, \u091c\u093f\u0938\u092e\u0947\u0902 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0908\u090f\u092e\u0938\u0940 \u0917\u094d\u0932\u0948\u0902\u0921 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0964.<\/figcaption><\/figure>\n<h2>\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0930\u0942\u091f\u093f\u0902\u0917 \u0915\u0940 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u090f\u0901<\/h2>\n<h3>\u0905\u0932\u0917\u093e\u0935 \u0938\u0902\u092c\u0902\u0927\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n<p>\u0909\u091a\u093f\u0924 \u0915\u0947\u092c\u0932 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u092f\u0941\u0917\u094d\u092e\u0928 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948 \u0914\u0930 \u0915\u0947\u092c\u0932 \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0905\u0917\u094d\u0928\u093f \u0905\u0935\u0930\u094b\u0927\u094b\u0902 \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948:<\/p>\n<p><strong>\u092d\u094c\u0924\u093f\u0915 \u0905\u0932\u0917\u093e\u0935<\/strong> \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u0947 \u092c\u0940\u091a \u0915\u0940 \u0926\u0942\u0930\u0940 300 \u092e\u093f\u092e\u0940 \u0928\u093f\u092f\u092e \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u2014\u0928\u094d\u092f\u0942\u0928\u0924\u092e 300 \u092e\u093f\u092e\u0940 \u0915\u0940 \u0926\u0942\u0930\u0940 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u093e \u092f\u093e \u091c\u092c \u0928\u093f\u0915\u091f\u0924\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u0924\u094b \u0927\u093e\u0924\u094d\u0935\u093f\u0915 \u0905\u0935\u0930\u094b\u0927\u0915 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u093e\u0964 15 kV \u0938\u0947 \u090a\u092a\u0930 \u0915\u0947 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930\u094b\u0902 \u092a\u0930 \u092f\u0939 \u0926\u0942\u0930\u0940 \u0906\u0928\u0941\u092a\u093e\u0924\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092c\u0922\u093c \u091c\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<p><strong>\u0915\u094b\u0923\u094b\u0902 \u0915\u093e \u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917<\/strong> 90\u00b0 \u0915\u0947 \u0915\u094b\u0923 \u0938\u0947 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0938\u0902\u092f\u0941\u0917\u094d\u092e\u0928 \u0915\u092e \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948 \u091c\u092c \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u094b \u092a\u093e\u0935\u0930 \u091a\u093e\u0932\u0915\u094b\u0902 \u0915\u0947 \u092a\u093e\u0930 \u091c\u093e\u0928\u093e \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0924\u093f\u0930\u091b\u0940 \u0915\u094d\u0930\u0949\u0938\u093f\u0902\u0917 \u0938\u0947 \u0932\u0902\u092c\u0940 \u0938\u0902\u092f\u0941\u0917\u094d\u092e\u0928 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u092c\u0928\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u094b \u0915\u093e\u092b\u0940 \u092c\u0922\u093c\u093e \u0926\u0947\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0932\u0902\u092c\u0935\u0924 \u0930\u0942\u091f\u093f\u0902\u0917<\/strong> \u0915\u0947\u092c\u0932 \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f\u094d\u0938 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0906\u0917-\u0930\u094b\u0927\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u094b \u092b\u0930\u094d\u0936 \u0914\u0930 \u091b\u0924 \u0915\u0947 \u091b\u093f\u0926\u094d\u0930\u094b\u0902 \u092a\u0930 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u092a\u0930\u0940\u0915\u094d\u0937\u0923-\u092a\u094d\u0930\u093e\u092a\u094d\u0924 \u0905\u0917\u094d\u0928\u093f \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u092a\u0942\u0930\u094d\u0935-\u0928\u093f\u0930\u094d\u092e\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u091f \u0938\u093f\u0938\u094d\u091f\u092e \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0915\u094b \u0938\u0930\u0932 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0932\u093e\u0907\u0928\u0905\u092a \u0915\u0947 \u092c\u093e\u0939\u0930 \u0932\u0902\u092c\u0940 \u0926\u0942\u0930\u0940 \u0915\u0947 \u092e\u093e\u0930\u094d\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0909\u0938\u0940 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u092f\u094b\u091c\u0928\u093e \u0915\u094b \u0938\u0902\u092f\u0902\u0924\u094d\u0930 \u0915\u0947\u092c\u0932 \u0938\u092e\u0930\u094d\u0925\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u092e\u0947\u0902 \u092d\u0940 \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902; \u090f\u0915 <a href=\"https:\/\/xmqj.com\/\" target=\"_blank\" rel=\"noopener\">\u0915\u0947\u092c\u0932 \u091f\u094d\u0930\u0947 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0917\u093e\u0907\u0921<\/a> \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932 \u0938\u0947 \u0928\u093f\u0915\u0932\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926 \u091f\u094d\u0930\u0947 \u0915\u0940 \u092d\u0930\u093e\u0908, \u0926\u0942\u0930\u0940, \u0905\u0917\u094d\u0928\u093f-\u0930\u094b\u0927\u0940 \u092c\u093f\u0902\u0926\u0941, \u0914\u0930 \u092e\u094b\u0921\u093c \u0924\u094d\u0930\u093f\u091c\u094d\u092f\u093e \u0915\u094b \u0938\u0941\u0938\u0902\u0917\u0924 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u0935\u0915\u094d\u0930 \u0924\u094d\u0930\u093f\u091c\u094d\u092f\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0935\u093f\u091a\u093e\u0930<\/h3>\n<p>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0935\u0915\u094d\u0930 \u0924\u094d\u0930\u093f\u091c\u094d\u092f\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u092a\u094d\u0930\u0924\u093f\u092c\u0902\u0927\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0924\u0928\u093e\u0935 \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u094b \u0938\u0902\u0924\u0941\u0932\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0902:<\/p>\n<ul>\n<li><strong>\u092c\u093f\u0928\u093e \u0906\u0935\u0930\u0923 \u0935\u093e\u0932\u0940 \u0915\u0947\u092c\u0932\u0947\u0902<\/strong>\u0915\u0941\u0932 \u0915\u0947\u092c\u0932 \u0935\u094d\u092f\u093e\u0938 \u0915\u093e \u0928\u094d\u092f\u0942\u0928\u0924\u092e 6 \u0917\u0941\u0928\u093e<\/li>\n<li><strong>\u092c\u0916\u094d\u0924\u0930\u092c\u0902\u0926 \u0915\u0947\u092c\u0932<\/strong>: \u0915\u0941\u0932 \u0935\u094d\u092f\u093e\u0938 \u0915\u093e \u0928\u094d\u092f\u0942\u0928\u0924\u092e 12 \u0917\u0941\u0928\u093e<\/li>\n<li><strong>\u092b\u093e\u0907\u092c\u0930 \u0911\u092a\u094d\u091f\u093f\u0915 \u0939\u093e\u0907\u092c\u094d\u0930\u093f\u0921 \u0915\u0947\u092c\u0932<\/strong>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930, \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0935\u094d\u092f\u093e\u0938 \u0915\u093e 15-20 \u0917\u0941\u0928\u093e<\/li>\n<\/ul>\n<p>\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092e\u094b\u0921\u093c \u0924\u094d\u0930\u093f\u091c\u094d\u092f\u093e \u0915\u0940 \u0938\u0940\u092e\u093e\u0913\u0902 \u0938\u0947 \u0905\u0927\u093f\u0915 \u092e\u094b\u0921\u093c\u0928\u0947 \u092a\u0930 \u0924\u094d\u0935\u0930\u093f\u0924 \u092f\u093e \u0905\u0902\u0924\u0930\u094d\u0928\u093f\u0939\u093f\u0924 \u0915\u094d\u0937\u0924\u093f \u0939\u094b\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u092e\u0947\u0902 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0915\u093e \u0932\u0902\u092c\u093e \u0939\u094b\u0928\u093e, \u0936\u0940\u0932\u094d\u0921 \u0915\u093e \u0935\u093f\u0915\u0943\u0924\u093f \u0939\u094b\u0928\u093e \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092e\u0947\u0902 \u0926\u0930\u093e\u0930\u0947\u0902 \u0906\u0928\u093e \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964 \u092e\u0948\u0902\u0928\u0947 \u0915\u0908 \u092c\u093e\u0930-\u092c\u093e\u0930 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0916\u0930\u093e\u092c\u0940 \u0915\u0940 \u091c\u093e\u0902\u091a\u094b\u0902 \u092e\u0947\u0902 \u092a\u093e\u092f\u093e \u0939\u0948 \u0915\u093f \u0924\u0940\u0916\u0947 \u092e\u094b\u0921\u093c\u094b\u0902 \u092a\u0930, \u0935\u093f\u0936\u0947\u0937\u0915\u0930 \u0938\u0902\u0915\u0940\u0930\u094d\u0923 \u092a\u0948\u0928\u0932 \u0906\u0935\u0930\u0923\u094b\u0902 \u0915\u0947 \u0905\u0902\u0926\u0930, \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0939\u0941\u0908 \u0915\u094d\u0937\u0924\u093f \u0926\u094b\u0937 \u0915\u093e \u092e\u0941\u0916\u094d\u092f \u0915\u093e\u0930\u0923 \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<h3>\u0915\u0947\u092c\u0932 \u0938\u092e\u0930\u094d\u0925\u0928 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/h3>\n<p>\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930, \u0915\u0947\u092c\u0932 \u0938\u092e\u0930\u094d\u0925\u0928 \u0924\u0902\u0924\u094d\u0930\u094b\u0902 \u0915\u094b \u0924\u093e\u092a\u0940\u092f \u091a\u0915\u094d\u0930\u0923, \u0915\u092e\u094d\u092a\u0928 \u0914\u0930 \u0930\u0916\u0930\u0916\u093e\u0935 \u092a\u0939\u0941\u0901\u091a \u0915\u0947 \u0905\u0928\u0941\u0915\u0942\u0932 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n<p><strong>\u0915\u0947\u092c\u0932 \u091f\u094d\u0930\u0947<\/strong> \u0909\u091a\u093f\u0924 \u092d\u0930\u093e\u0908 \u0905\u0928\u0941\u092a\u093e\u0924 (\u092a\u093e\u0935\u0930 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0927\u093f\u0915\u0924\u092e 40%, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 50%) \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u090a\u0937\u094d\u092e\u093e \u0905\u092a\u0935\u094d\u092f\u092f \u0914\u0930 \u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u0915\u0947\u092c\u0932 \u091c\u094b\u0921\u093c\u0928\u0947 \u0915\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u0940\u0922\u093c\u0940-\u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0940 \u091f\u094d\u0930\u0947 \u0920\u094b\u0938 \u0924\u0932 \u0935\u093e\u0932\u0947 \u0935\u093f\u0915\u0932\u094d\u092a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u090a\u0930\u094d\u0927\u094d\u0935\u093e\u0927\u0930 \u0915\u0947\u092c\u0932 \u0921\u094d\u0930\u0949\u092a \u0915\u094b \u092c\u0947\u0939\u0924\u0930 \u0922\u0902\u0917 \u0938\u0947 \u0938\u0941\u0917\u092e \u092c\u0928\u093e\u0924\u0940 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0915\u0947\u092c\u0932 \u0915\u094d\u0932\u093f\u091f\u094d\u0938<\/strong> \u0909\u091a\u093f\u0924 \u0905\u0902\u0924\u0930\u093e\u0932\u094b\u0902 \u092a\u0930 \u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0947\u092c\u0932 \u0915\u0940 \u0917\u0924\u093f \u0915\u094b \u0930\u094b\u0915\u0947\u0902\u0964 \u0915\u094d\u0932\u0940\u091f \u0938\u094d\u092a\u0947\u0938\u093f\u0902\u0917 \u0915\u0940 \u0917\u0923\u0928\u093e\u0913\u0902 \u092e\u0947\u0902 CT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u092a\u0930 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u094b \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/p>\n<p><strong>\u0932\u091a\u0940\u0932\u0947 \u0928\u0932\u0940 \u0938\u0902\u0915\u094d\u0930\u092e\u0923<\/strong> \u092a\u0948\u0928\u0932 \u092a\u094d\u0930\u0935\u0947\u0936 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u092a\u0930 \u0906\u092f\u093e\u092e\u0940 \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e\u0913\u0902 \u0914\u0930 \u091b\u094b\u091f\u0947 \u092a\u0948\u0928\u0932 \u0938\u094d\u0925\u093e\u0928\u093e\u0902\u0924\u0930\u0923\u094b\u0902 \u0915\u094b \u0938\u092e\u093e\u092f\u094b\u091c\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u0932\u093f\u0915\u094d\u0935\u093f\u091f\u093e\u0907\u091f \u0932\u091a\u0940\u0932\u093e \u0927\u093e\u0924\u094d\u0935\u093f\u0915 \u0928\u0932\u093f\u0915\u093e \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948 \u0914\u0930 \u0938\u0902\u0936\u094b\u0927\u0928\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0915\u0947\u092c\u0932 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<hr \/>\n<h2>\u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u092e\u093e\u092a\u094d\u0924\u093f \u092a\u094d\u0930\u0925\u093e\u090f\u0901<\/h2>\n<h3>\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u093e \u091a\u092f\u0928<\/h3>\n<p>\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u093e \u091a\u092f\u0928 \u0926\u0940\u0930\u094d\u0918\u0915\u093e\u0932\u093f\u0915 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u094b \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0930\u0942\u092a \u0938\u0947 \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948:<\/p>\n<p><strong>\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u0932\u094b\u0921\u0947\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/strong> \u0924\u093e\u092a\u092e\u093e\u0928 \u091a\u0915\u094d\u0930\u0923 \u0914\u0930 \u0915\u0902\u092a\u0928 \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926 \u0928\u093f\u0930\u0902\u0924\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0926\u092c\u093e\u0935 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0902\u0964 \u0906\u0935\u0927\u093f\u0915 \u0930\u0940-\u091f\u0949\u0915\u093f\u0902\u0917 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930\u0928\u0947 \u0938\u0947 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u094b \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0924\u0947\u091c\u0940 \u0938\u0947 \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u0915\u093f\u092f\u093e \u091c\u093e \u0930\u0939\u093e \u0939\u0948\u0964.<\/p>\n<p><strong>\u0938\u094d\u0915\u094d\u0930\u0942-\u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/strong> \u092c\u0921\u093c\u0947 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0906\u0915\u093e\u0930\u094b\u0902 \u0914\u0930 \u0926\u0943\u0936\u094d\u092f \u091f\u0949\u0930\u094d\u0915 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0935\u093e\u0932\u0947 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u0928\u0915 \u092c\u0928\u093e \u0930\u0939\u0947 \u0939\u0948\u0902\u0964 \u0909\u091a\u093f\u0924 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f\u0947\u0921 \u091f\u0949\u0930\u094d\u0915 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0914\u0930 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u091a\u093f\u0939\u094d\u0928\u094b\u0902 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<p><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0935\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u0915\u0928\u0947\u0915\u094d\u091f\u0930\u094d\u0938 (IDC)<\/strong> \u091b\u094b\u091f\u0947 \u0917\u0947\u091c \u0938\u093f\u0917\u094d\u0928\u0932 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0940 \u0924\u094d\u0935\u0930\u093f\u0924 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0938\u091f\u0940\u0915 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0917\u0947\u091c \u092e\u093f\u0932\u093e\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 IDC \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0909\u0928 \u0938\u0902\u091a\u093e\u0930 \u0914\u0930 \u0928\u093f\u092e\u094d\u0928-\u0938\u094d\u0924\u0930\u0940\u092f \u0938\u093f\u0917\u094d\u0928\u0932 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u0948\u0902 \u091c\u0939\u093e\u0901 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u0940 \u0917\u0924\u093f \u0917\u0947\u091c \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u094b \u0909\u091a\u093f\u0924 \u0920\u0939\u0930\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<h3>\u0915\u094d\u0930\u093f\u092e\u094d\u092a \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n<p>\u0938\u0939\u0940 \u0924\u0930\u0940\u0915\u0947 \u0938\u0947 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u092a\u0930 \u0915\u094d\u0930\u093f\u092e\u094d\u092a\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0938\u094d\u0915\u094d\u0930\u0942 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u092c\u0947\u0939\u0924\u0930 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n<p><strong>\u0915\u094d\u0930\u093f\u092e\u094d\u092a \u091f\u0942\u0932 \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u0936\u0928<\/strong> \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u0924\u094d\u0930\u0948\u092e\u093e\u0938\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0915\u093f\u092f\u093e \u091c\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0918\u093f\u0938\u0947 \u0939\u0941\u090f \u0921\u093e\u0907\u091c\u093c \u0922\u0940\u0932\u0947 \u0915\u094d\u0930\u093f\u092e\u094d\u092a\u094d\u0938 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u0926\u0943\u0936\u094d\u092f \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u0947\u0902 \u092a\u093e\u0938 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u0905\u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u0902\u092a\u0930\u094d\u0915 \u0926\u092c\u093e\u0935 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0924\u0948\u092f\u093e\u0930\u0940<\/strong> \u0907\u0938\u092e\u0947\u0902 \u0909\u091a\u093f\u0924 \u0938\u094d\u091f\u094d\u0930\u093f\u092a \u0915\u0940 \u0932\u0902\u092c\u093e\u0908 (\u092c\u0948\u0930\u0932 \u0915\u0947 \u092c\u093e\u0939\u0930 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0915\u0947 \u0909\u091c\u093e\u0917\u0930 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092c\u091a\u093e\u0935), \u0938\u094d\u091f\u094d\u0930\u0948\u0902\u0921 \u0915\u0940 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e (\u092c\u093f\u0928\u093e \u0915\u091f\u0947 \u092f\u093e \u0915\u094d\u0930\u0949\u0938 \u0939\u0941\u090f \u0938\u094d\u091f\u094d\u0930\u0948\u0902\u0921), \u0914\u0930 \u0938\u094d\u0935\u091a\u094d\u091b\u0924\u093e (\u092a\u0941\u0930\u093e\u0928\u0947 \u0915\u0902\u0921\u0915\u094d\u091f\u0930\u094b\u0902 \u092a\u0930 \u0911\u0915\u094d\u0938\u093e\u0907\u0921 \u0915\u0940 \u092a\u0930\u0924\u0947\u0902 \u0939\u091f\u093e\u0928\u093e) \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u0915\u094d\u0930\u093f\u092e\u094d\u092a \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u092e\u093e\u0928\u0926\u0902\u0921<\/strong> \u0907\u0938\u092e\u0947\u0902 \u0909\u091a\u093f\u0924 \u0921\u093e\u0908 \u0915\u094d\u0932\u094b\u091c\u0930, \u0915\u0947\u0902\u0926\u094d\u0930\u093f\u0924 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0938\u094d\u0925\u093f\u0924\u093f \u0914\u0930 \u092c\u0948\u0930\u0932 \u0915\u0947 \u0938\u093f\u0930\u0947 \u092a\u0930 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0915\u093e \u0938\u094d\u092a\u0937\u094d\u091f \u0909\u092d\u093e\u0930 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964 \u0915\u0908 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u092e\u0947\u0902 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u092a\u0930 \u0915\u094d\u0930\u093f\u092e\u094d\u092a\u094d\u0938 \u0915\u093e 100% \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u0936\u0940\u0932\u094d\u0921 \u0938\u092e\u093e\u092a\u094d\u0924\u093f \u0935\u093f\u0927\u093f\u092f\u093e\u0901<\/h3>\n<p>\u0936\u0940\u0932\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u0940 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0938\u0940\u0927\u0947 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948:<\/p>\n<p><strong>360-\u0921\u093f\u0917\u094d\u0930\u0940 \u0938\u092e\u093e\u092a\u094d\u0924\u093f<\/strong> EMC \u0915\u0947\u092c\u0932 \u0917\u094d\u0932\u0948\u0902\u0921\u094d\u0938 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u092a\u0942\u0930\u094d\u0923 \u092a\u0930\u093f\u0927\u0940\u092f \u0936\u0940\u0932\u094d\u0921 \u0938\u0902\u092a\u0930\u094d\u0915 \u092a\u094d\u0930\u0926\u093e\u0928 \u0939\u094b\u0924\u093e \u0939\u0948, \u091c\u094b \u092a\u0948\u0928\u0932 \u092a\u094d\u0930\u0935\u0947\u0936 \u092c\u093f\u0902\u0926\u0941 \u092a\u0930 \u0936\u0940\u0932\u094d\u0921 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u0948\u0964 \u092f\u0939 \u0935\u093f\u0927\u093f 10 \u092e\u0947\u0917\u093e\u0939\u0930\u094d\u091f\u094d\u091c\u093c \u0938\u0947 \u090a\u092a\u0930 \u0915\u0940 \u0906\u0935\u0943\u0924\u094d\u0924\u093f\u092f\u094b\u0902 \u092a\u0930 \u092a\u093f\u0917\u091f\u0947\u0932 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 40\u201360 \u0921\u0947\u0938\u0940\u092c\u0932 \u0905\u0927\u093f\u0915 \u0936\u094b\u0930 \u0905\u0938\u094d\u0935\u0940\u0915\u0943\u0924\u093f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<p><strong>\u092a\u093f\u0917\u091f\u0947\u0932 \u0915\u0928\u0947\u0915\u094d\u0936\u0928<\/strong> (\u0936\u0940\u0932\u094d\u0921 \u0921\u094d\u0930\u0947\u0928 \u0935\u093e\u092f\u0930 \u0915\u094b \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092c\u0938 \u0938\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u091f \u0915\u0930\u0928\u093e) \u0938\u0930\u0932\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u090f\u0915 \u092a\u094d\u0930\u0947\u0930\u0915 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u091c\u094b \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u0940 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0915\u094b \u0915\u092e \u0915\u0930 \u0926\u0947\u0924\u0940 \u0939\u0948\u0964 \u091c\u092c \u092a\u093f\u0917\u091f\u0947\u0932\u094d\u0938 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0939\u094b\u0902, \u0924\u094b \u0909\u0928\u0915\u0940 \u0932\u0902\u092c\u093e\u0908 50 \u092e\u093f\u092e\u0940 \u0938\u0947 \u0915\u092e \u0930\u0916\u0947\u0902 \u0914\u0930 \u0909\u0928\u094d\u0939\u0947\u0902 \u0928\u093f\u0915\u091f\u0924\u092e \u0917\u094d\u0930\u093e\u0909\u0902\u0921 \u092c\u093f\u0902\u0926\u0941 \u0924\u0915 \u0938\u0940\u0927\u0947 \u092e\u093e\u0930\u094d\u0917\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n<p><strong>\u0936\u0940\u0932\u094d\u0921 \u092c\u0938 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/strong> \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0936\u0940\u0932\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u094b \u090f\u0915 \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u092e\u0935\u093f\u092d\u0935 \u0938\u0924\u0939 \u092e\u0947\u0902 \u090f\u0915\u0940\u0915\u0943\u0924 \u0915\u0930\u0947\u0902, \u091c\u093f\u0938\u0938\u0947 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0930\u0932 \u0939\u094b \u0914\u0930 \u0909\u091a\u093f\u0924 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u092c\u0928\u0940 \u0930\u0939\u0947\u0964 \u0915\u0908 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0948\u0928\u0932 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u090f \u0917\u090f \u092e\u0949\u0921\u094d\u092f\u0942\u0932\u0930 \u0936\u0940\u0932\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0938\u093f\u0938\u094d\u091f\u092e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<hr \/>\n<h2>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e\u090f\u0901<\/h2>\n<h3>\u0938\u094d\u0925\u093e\u092a\u0928\u093e-\u092a\u0942\u0930\u094d\u0935 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n<p>\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0947 \u092a\u0939\u0932\u0947, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923\u094b\u0902 \u0938\u0947 \u0917\u0941\u091c\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f:<\/p>\n<p><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong> \u0928\u094d\u092f\u0942\u0928\u0924\u092e 500VDC \u092a\u0930, \u092e\u093e\u092a\u0928 \u0930\u0940\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0924\u093f \u0915\u093f\u0932\u094b\u092e\u0940\u091f\u0930 100 M\u03a9 \u0938\u0947 \u0905\u0927\u093f\u0915 \u0939\u094b\u0928\u0947 \u092a\u0930 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u093f\u092f\u093e \u091c\u093e\u0924\u093e \u0939\u0948\u0964 \u0915\u092e \u0930\u0940\u0921\u093f\u0902\u0917\u094d\u0938 \u0928\u092e\u0940 \u092a\u094d\u0930\u0935\u0947\u0936 \u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0926\u094b\u0937\u094b\u0902 \u0915\u093e \u0938\u0902\u0915\u0947\u0924 \u0926\u0947\u0924\u0940 \u0939\u0948\u0902, \u091c\u093f\u0938\u0915\u0947 \u0915\u093e\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u094b \u0905\u0938\u094d\u0935\u0940\u0915\u093e\u0930 \u0915\u0930\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/p>\n<p><strong>\u0938\u0924\u0924\u0924\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/strong> \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0947 \u092a\u0939\u0932\u0947 \u091a\u093e\u0932\u0915 \u0915\u0940 \u0905\u0916\u0902\u0921\u0924\u093e \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0924\u093e \u0939\u0948 \u0914\u0930 \u0915\u094d\u0930\u0949\u0938\u094d\u0921 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u092c\u093e\u0926 \u092e\u0947\u0902 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0928\u093e \u092e\u0941\u0936\u094d\u0915\u093f\u0932 \u0939\u094b \u091c\u093e\u0924\u093e \u0939\u0948\u0964.<\/p>\n<p><strong>\u0936\u0940\u0932\u094d\u0921 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong> \u0915\u092e \u0927\u093e\u0930\u093e \u0938\u094d\u0924\u0930\u094b\u0902 \u092a\u0930 \u0936\u0940\u0932\u094d\u0921 \u091f\u0942\u091f\u0928\u0947 \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948 \u091c\u094b \u0908\u090f\u092e\u0938\u0940 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<h3>\u0938\u094d\u0925\u093e\u092a\u0928\u093e-\u0909\u092a\u0930\u093e\u0902\u0924 \u091a\u093e\u0932\u0942\u0915\u0930\u0923 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/h3>\n<p>\u0938\u092e\u093e\u092a\u094d\u0924\u093f \u092a\u0942\u0930\u094d\u0923 \u0939\u094b\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926:<\/p>\n<p><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u0941\u0928\u0903 \u092a\u0930\u0940\u0915\u094d\u0937\u0923<\/strong> \u0938\u093e\u0925-\u0938\u093e\u0925 \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u0940 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0917\u0924\u093f\u0935\u093f\u0927\u093f\u092f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0916\u0940\u0902\u091a\u0928\u0947 \u0915\u0947 \u0924\u0928\u093e\u0935, \u0924\u0940\u0916\u0947 \u092e\u094b\u0921\u093c\u094b\u0902, \u092f\u093e \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092a\u094d\u0930\u092d\u093e\u0935\u094b\u0902 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0915\u094d\u0937\u0924\u093f \u0915\u0940 \u092a\u0939\u091a\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<p><strong>\u092c\u093f\u0902\u0926\u0941-\u0938\u0947-\u092c\u093f\u0902\u0926\u0941 \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/strong> \u0924\u093e\u0930\u094b\u0902 \u0915\u0947 \u0906\u0930\u0947\u0916\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0938\u0939\u0940 \u0938\u092e\u093e\u092a\u094d\u0924\u093f \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u094b \u090a\u0930\u094d\u091c\u093e \u0926\u0947\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0939\u0948\u0964.<\/p>\n<p><strong>\u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u092e\u093e\u092a<\/strong> \u0932\u094b\u0921 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0924\u0939\u0924 \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u092e\u0947\u0902 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0938\u094d\u0924\u0930\u094b\u0902 \u0915\u094b \u092e\u093e\u0924\u094d\u0930\u093e\u0924\u094d\u092e\u0915 \u0930\u0942\u092a \u0938\u0947 \u092e\u093e\u092a\u0947\u0902\u0964 \u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0938\u093f\u0917\u094d\u0928\u0932 \u0938\u094d\u0924\u0930\u094b\u0902 \u0938\u0947 1% \u0938\u0947 \u0905\u0927\u093f\u0915 \u092e\u093e\u092a\u094b\u0902 \u0915\u0940 \u091c\u093e\u0902\u091a \u0914\u0930 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964.<\/p>\n<p><strong>\u0922\u093e\u0932 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u0928<\/strong> \u0907\u0902\u091c\u0947\u0915\u094d\u0936\u0928 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0935\u093f\u0928\u094d\u092f\u093e\u0938\u094b\u0902 \u092e\u0947\u0902 \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<hr \/>\n<h2>\u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0914\u0930 \u0915\u0947\u0938 \u0938\u094d\u091f\u0921\u0940\u091c\u093c<\/h2>\n<h3>\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u092a\u0947\u091f\u094d\u0930\u094b\u0915\u0947\u092e\u093f\u0915\u0932 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u093e \u0928\u0935\u0940\u0928\u0940\u0915\u0930\u0923<\/h3>\n<p>\u0939\u093e\u0932 \u0939\u0940 \u092e\u0947\u0902 \u0917\u0932\u094d\u092b \u0915\u094b\u0938\u094d\u091f \u0930\u093f\u092b\u093e\u0907\u0928\u0930\u0940 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0909\u0928\u094d\u0928\u092f\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928, \u092e\u094c\u091c\u0942\u0926\u093e 13.8 kV \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u092e\u0947\u0902 \u0926\u0940\u0930\u094d\u0918\u0915\u093e\u0932\u093f\u0915 \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u092a\u093e\u0908 \u0917\u0908\u0902\u0964 \u092a\u0930\u093f\u0935\u0930\u094d\u0924\u0928\u0940\u092f \u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0921\u094d\u0930\u093e\u0907\u0935 \u092a\u093e\u0935\u0930 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0938\u092e\u0940\u092a \u092e\u093e\u0930\u094d\u0917\u093f\u0924 CT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0936\u094b\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0915\u0940 \u092b\u093c\u093f\u0932\u094d\u091f\u0930\u093f\u0902\u0917 \u0915\u094d\u0937\u092e\u0924\u093e \u0938\u0947 \u0905\u0927\u093f\u0915 \u0925\u093e, \u091c\u093f\u0938\u0938\u0947 \u092e\u094b\u091f\u0930 \u0938\u094d\u091f\u093e\u0930\u094d\u091f\u093f\u0902\u0917 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0928\u093e\u0935\u0936\u094d\u092f\u0915 \u091f\u094d\u0930\u093f\u092a \u0939\u094b\u0924\u0940 \u0925\u0940\u0964.<\/p>\n<p>\u0938\u092e\u093e\u0927\u093e\u0928 \u092e\u0947\u0902 \u0938\u092d\u0940 CT \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0930\u0942\u092a \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u091f\u094d\u0930\u093e\u092f\u0921\u094d\u0938 \u0915\u094b \u0938\u0902\u092f\u094b\u091c\u0928 \u092b\u0949\u092f\u0932\/\u092c\u094d\u0930\u0947\u0921\u0947\u0921 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u0947 \u0938\u093e\u0925 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0928\u093e, \u0926\u094b\u0928\u094b\u0902 \u0938\u093f\u0930\u094b\u0902 \u092a\u0930 360-\u0921\u093f\u0917\u094d\u0930\u0940 \u0936\u0940\u0932\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0932\u093e\u0917\u0942 \u0915\u0930\u0928\u093e, \u0914\u0930 VFD \u092a\u093e\u0935\u0930 \u0915\u0902\u0921\u0915\u094d\u091f\u0930\u094d\u0938 \u0938\u0947 \u0928\u094d\u092f\u0942\u0928\u0924\u092e 450 \u092e\u093f\u092e\u0940 \u0915\u0940 \u0926\u0942\u0930\u0940 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u093e \u092a\u0941\u0928\u0930\u094d\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0915\u0930\u0928\u093e \u0936\u093e\u092e\u093f\u0932 \u0925\u093e\u0964 \u0938\u0902\u0936\u094b\u0927\u0928 \u0915\u0947 \u092c\u093e\u0926 \u0915\u0947 \u092e\u093e\u092a\u094b\u0902 \u0928\u0947 \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0936\u094b\u0930 \u092e\u0947\u0902 850 mV \u092a\u0940\u0915 \u0938\u0947 \u0918\u091f\u0915\u0930 15 mV \u0938\u0947 \u092d\u0940 \u0915\u092e \u0915\u0940 \u0915\u092e\u0940 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0940\u2014\u091c\u094b \u0930\u093f\u0932\u0947 \u0938\u0939\u0928\u0936\u0940\u0932\u0924\u093e \u0915\u0947 \u092d\u0940\u0924\u0930 \u0939\u0948\u0964.<\/p>\n<h3>\u0909\u092a\u092f\u094b\u0917\u093f\u0924\u093e \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928 \u0915\u093e \u0928\u092f\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923<\/h3>\n<p>\u090f\u0915 230\/34.5 kV \u091f\u094d\u0930\u093e\u0902\u0938\u092e\u093f\u0936\u0928 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u092e\u0947\u0902 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u092f\u0942\u091f\u093f\u0932\u093f\u091f\u0940 \u0915\u0940 \u0906\u0917 \u0938\u0902\u092c\u0902\u0927\u0940 \u0918\u091f\u0928\u093e\u0913\u0902 \u0915\u0940 \u091a\u093f\u0902\u0924\u093e\u0913\u0902 \u0915\u0947 \u092e\u0926\u094d\u0926\u0947\u0928\u091c\u093c\u0930 \u0938\u092d\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u0947\u092c\u0932 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u093f\u090f \u0917\u090f\u0964 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915 \u0925\u093e:<\/p>\n<ul>\n<li>\u0921\u093f\u092b\u0930\u0947\u0902\u0936\u093f\u092f\u0932 \u092a\u094d\u0930\u094b\u091f\u0947\u0915\u094d\u0936\u0928, \u092c\u094d\u0930\u0947\u0915\u0930 \u092b\u0947\u0932\u094d\u092f\u094b\u0930, \u0914\u0930 \u092c\u0938 \u092a\u094d\u0930\u094b\u091f\u0947\u0915\u094d\u0936\u0928 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0932\u093f\u090f IEC 60331-\u0905\u0928\u0941\u092a\u093e\u0932\u0915 \u0915\u0947\u092c\u0932<\/li>\n<li>IEC 60332-3 \u0936\u094d\u0930\u0947\u0923\u0940 A \u0915\u0947\u092c\u0932 \u0938\u092d\u0940 \u0905\u0928\u094d\u092f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0914\u0930 \u0938\u0902\u0915\u0947\u0924 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<li>\u092a\u0930\u0940\u0915\u094d\u0937\u093f\u0924 \u0914\u0930 \u0905\u0928\u0941\u092e\u094b\u0926\u093f\u0924 \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u091f \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0915\u0947 \u0938\u092d\u0940 \u091b\u093f\u0926\u094d\u0930\u094b\u0902 \u092a\u0930 \u0935\u094d\u092f\u093e\u092a\u0915 \u0905\u0917\u094d\u0928\u093f \u0905\u0935\u0930\u094b\u0927\u0928\u0964<\/li>\n<\/ul>\n<p>18 \u092e\u0939\u0940\u0928\u0947 \u0915\u0947 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0915\u094b\u0908 \u092d\u0940 \u0917\u0932\u0924 \u0938\u0902\u091a\u093e\u0932\u0928 \u0928\u0939\u0940\u0902 \u0939\u0941\u0906, \u091c\u093f\u0938\u0938\u0947 \u0930\u0942\u0922\u093c\u093f\u0935\u093e\u0926\u0940 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0926\u0943\u0937\u094d\u091f\u093f\u0915\u094b\u0923 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0939\u094b\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<hr \/>\n<h2>\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n<h3>\u092a\u094d\u0930\u0936\u094d\u0928 1: \u092e\u0948\u0902 \u0915\u0948\u0938\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0942\u0901 \u0915\u093f \u092e\u0947\u0930\u0940 \u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0932\u093f\u090f \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0902?<\/h3>\n<p>\u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u0915\u0947\u092c\u0932 \u0924\u092c \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b \u091c\u093e\u0924\u0947 \u0939\u0948\u0902 \u091c\u092c \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u093e\u0935\u0930 \u091a\u093e\u0932\u0915\u094b\u0902 \u0938\u0947 300 \u092e\u093f\u092e\u0940 \u0915\u0947 \u092d\u0940\u0924\u0930 \u092e\u093e\u0930\u094d\u0917\u093f\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u0902\u0915\u0947\u0924 (1V \u092f\u093e \u092e\u093e\u0907\u0915\u094d\u0930\u094b\u090f\u092e\u094d\u092a\u093f\u092f\u0930 \u0938\u094d\u0924\u0930 \u0938\u0947 \u0915\u092e) \u092e\u094c\u091c\u0942\u0926 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u092c \u0938\u0902\u091a\u093e\u0930 \u092a\u094d\u0930\u094b\u091f\u094b\u0915\u0949\u0932 \u0935\u093f\u0936\u093f\u0937\u094d\u091f EMC \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0930\u0916\u0924\u0947 \u0939\u0948\u0902, \u092f\u093e \u091c\u092c \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0935\u0947\u0930\u093f\u090f\u092c\u0932 \u092b\u094d\u0930\u093f\u0915\u094d\u0935\u0947\u0902\u0938\u0940 \u0921\u094d\u0930\u093e\u0907\u0935, \u0906\u0930\u094d\u0915 \u092d\u091f\u094d\u0920\u093f\u092f\u093e\u0901, \u092f\u093e \u0905\u0928\u094d\u092f \u0909\u091a\u094d\u091a \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0938\u094d\u0930\u094b\u0924 \u0936\u093e\u092e\u093f\u0932 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u090f \u090f\u092e\u0935\u0940 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f, \u0936\u094b\u0930-\u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u0947 \u0928\u093f\u0935\u093e\u0930\u0923 \u0915\u0940 \u0932\u093e\u0917\u0924 \u0915\u094b \u0927\u094d\u092f\u093e\u0928 \u092e\u0947\u0902 \u0930\u0916\u0924\u0947 \u0939\u0941\u090f, \u0938\u093e\u0930\u094d\u0935\u092d\u094c\u092e\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u093e \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u0905\u0915\u094d\u0938\u0930 \u091a\u092f\u0928\u093f\u0924 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 \u0905\u0927\u093f\u0915 \u0906\u0930\u094d\u0925\u093f\u0915 \u0938\u093e\u092c\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u092a\u094d\u0930\u0936\u094d\u0928 2: \u0905\u0917\u094d\u0928\u093f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0947 \u0938\u0902\u0926\u0930\u094d\u092d \u092e\u0947\u0902 LSZH \u0914\u0930 \u092e\u093e\u0928\u0915 PVC \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932\u094b\u0902 \u092e\u0947\u0902 \u0915\u094d\u092f\u093e \u0905\u0902\u0924\u0930 \u0939\u0948?<\/h3>\n<p>LSZH (\u0932\u094b \u0938\u094d\u092e\u094b\u0915 \u091c\u0940\u0930\u094b \u0939\u0948\u0932\u094b\u091c\u0928) \u0915\u0947\u092c\u0932 \u092a\u0949\u0932\u0940\u0913\u0932\u0947\u092b\u093f\u0928-\u0906\u0927\u093e\u0930\u093f\u0924 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0914\u0930 \u091c\u0948\u0915\u0947\u091f\u093f\u0902\u0917 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0926\u0939\u0928 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0927\u0941\u0906\u0902 \u0914\u0930 \u0915\u094b\u0908 \u0915\u094d\u0937\u0930\u0923\u0915\u093e\u0930\u0940 \u0905\u092e\u094d\u0932\u0940\u092f \u0917\u0948\u0938 \u0928\u0939\u0940\u0902 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u0947\u0964 \u092e\u093e\u0928\u0915 \u092a\u0940\u0935\u0940\u0938\u0940 \u0915\u0947\u092c\u0932 \u091c\u0932\u0928\u0947 \u092a\u0930 \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u091c\u0928 \u0915\u094d\u0932\u094b\u0930\u093e\u0907\u0921 \u0917\u0948\u0938 \u091b\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0928\u092e\u0940 \u0915\u0940 \u0909\u092a\u0938\u094d\u0925\u093f\u0924\u093f \u092e\u0947\u0902 \u0939\u093e\u0907\u0921\u094d\u0930\u094b\u0915\u094d\u0932\u094b\u0930\u093f\u0915 \u090f\u0938\u093f\u0921 \u092c\u0928\u093e\u0924\u0940 \u0939\u0948, \u091c\u093f\u0938\u0938\u0947 \u0906\u0938-\u092a\u093e\u0938 \u0915\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u094d\u0937\u0924\u093f\u0917\u094d\u0930\u0938\u094d\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902 \u0914\u0930 \u0936\u094d\u0935\u0938\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0916\u0924\u0930\u0947 \u092a\u0948\u0926\u093e \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u091c\u092c\u0915\u093f LSZH \u0915\u0947\u092c\u0932 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u092a\u0940\u0935\u0940\u0938\u0940 \u0938\u092e\u0915\u0915\u094d\u0937\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 15\u201325% \u0905\u0927\u093f\u0915 \u092e\u0939\u0902\u0917\u0947 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u094b \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0947 \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u0915\u094d\u0937\u0924\u093f \u092e\u0947\u0902 \u0915\u092e\u0940 \u0914\u0930 \u092c\u0947\u0939\u0924\u0930 \u0928\u093f\u0915\u093e\u0938\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0935\u093e\u0932\u0947 \u092c\u0902\u0926 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u0914\u0930 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u092e\u0947\u0902 \u0907\u0938 \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e \u0915\u094b \u0909\u091a\u093f\u0924 \u0920\u0939\u0930\u093e\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<h3>Q3: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 CT \u0938\u0947\u0915\u0947\u0902\u0921\u0930\u0940 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u094b \u0921\u093f\u091c\u093f\u091f\u0932 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u090f\u0915 \u0939\u0940 \u0915\u0902\u0921\u0941\u0907\u091f \u092e\u0947\u0902 \u0930\u093e\u0909\u091f \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/h3>\n<p>\u0939\u093e\u0901, \u0909\u091a\u093f\u0924 \u0938\u093e\u0935\u0927\u093e\u0928\u093f\u092f\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925\u0964  CT \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u094d\u092f\u0915\u094d\u0924\u093f\u0917\u0924 \u0930\u0942\u092a \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u0915\u0947\u092c\u0932 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 \u0924\u093e\u0915\u093f \u0928\u093f\u0915\u091f\u0935\u0930\u094d\u0924\u0940 \u091a\u093e\u0932\u0915\u094b\u0902 \u092e\u0947\u0902 \u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0915\u093e \u0938\u0902\u091a\u0930\u0923 \u0928 \u0939\u094b\u0964  \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0915\u0902\u0921\u094d\u092f\u0942\u0907\u091f \u092d\u0930\u093e\u0908 \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0947\u092c\u0932 \u092a\u094d\u0930\u0915\u093e\u0930\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0926\u0942\u0930\u0940 \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u093e \u0939\u094b\u0964  \u0924\u094d\u0930\u0941\u091f\u093f \u0927\u093e\u0930\u093e \u0938\u094d\u0924\u0930\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0902\u2014CT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u093e\u0935\u0930 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0927\u093e\u0930\u093e\u090f\u0901 \u0935\u0939\u0928 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0914\u0930 \u091a\u093e\u0932\u0915 \u0915\u0947 \u0906\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u092e\u0947\u0902 \u0924\u093e\u092a\u0940\u092f \u092a\u094d\u0930\u092d\u093e\u0935\u094b\u0902 \u0915\u093e \u0927\u094d\u092f\u093e\u0928 \u0930\u0916\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964  \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0905\u0932\u0917 \u092e\u093e\u0930\u094d\u0917 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u092e\u093e\u092e\u0942\u0932\u0940 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0932\u093e\u0917\u0924 \u0915\u0947 \u092c\u093e\u0935\u091c\u0942\u0926 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u092a\u094d\u0930\u0936\u094d\u0928 4: IEC 61850 GOOSE \u0938\u0902\u091a\u093e\u0930 \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u091d\u0947 \u0915\u094c\u0928 \u0938\u0940 \u0936\u0940\u0932\u094d\u0921 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0935\u093f\u0927\u093f \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>IEC 61850 GOOSE (\u091c\u0947\u0928\u0947\u0930\u093f\u0915 \u0911\u092c\u094d\u091c\u0947\u0915\u094d\u091f \u0913\u0930\u093f\u090f\u0902\u091f\u0947\u0921 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u0907\u0935\u0947\u0902\u091f) \u0938\u0902\u091a\u093e\u0930 \u0908\u0925\u0930\u0928\u0947\u091f \u0917\u0924\u093f \u092a\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948, \u091c\u093f\u0938\u0915\u0947 \u0932\u093f\u090f \u092c\u094d\u0930\u0949\u0921\u092c\u0948\u0902\u0921 \u0936\u094b\u0930 \u092a\u094d\u0930\u0924\u093f\u0930\u0915\u094d\u0937\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964  \u0915\u0947\u092c\u0932 \u0915\u0947 \u0926\u094b\u0928\u094b\u0902 \u0938\u093f\u0930\u094b\u0902 \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u092e\u0927\u094d\u092f\u0935\u0930\u094d\u0924\u0940 \u091c\u0902\u0915\u094d\u0936\u0928 \u092c\u093f\u0902\u0926\u0941 \u092a\u0930 \u092c\u0939\u0941-\u092c\u093f\u0902\u0926\u0941 \u0936\u0940\u0932\u094d\u0921 \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0909\u091a\u094d\u091a-\u0906\u0935\u0943\u0924\u094d\u0924\u093f \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964  \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0917\u090f \u092a\u0948\u091a \u0915\u0947\u092c\u0932\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u094b\u0902 \u0924\u0925\u093e \u092a\u0948\u091a \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0936\u0940\u0932\u094d\u0921 \u0915\u0940 \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964  \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u092c\u093f\u0902\u0926\u0941 \u092a\u0930 \u0936\u0940\u0932\u094d\u0921 \u0915\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e\u0924\u094d\u092e\u0915 \u0905\u0930\u094d\u0925 \u0938\u093f\u0938\u094d\u091f\u092e \u0938\u0947 \u091c\u094b\u0921\u093c\u0928\u093e \u091a\u093e\u0939\u093f\u090f, \u091c\u093f\u0938\u0938\u0947 \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0927\u093e\u0930\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092e\u094d\u0928 \u092a\u094d\u0930\u0924\u093f\u092c\u093e\u0927\u093e \u0935\u093e\u0932\u093e \u092e\u093e\u0930\u094d\u0917 \u092c\u0928\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>Q5: \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u094b \u0915\u093f\u0924\u0928\u0940 \u092c\u093e\u0930 \u092b\u093f\u0930 \u0938\u0947 \u0915\u0938\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>\u0938\u094d\u0915\u094d\u0930\u0942-\u091f\u093e\u0907\u092a \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u094b \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 (\u0924\u093e\u092a\u0940\u092f \u0938\u094d\u0925\u093f\u0930\u0940\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f 24-48 \u0918\u0902\u091f\u0947 \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u092c\u093e\u0926), \u092a\u0939\u0932\u0947 \u0935\u093e\u0930\u094d\u0937\u093f\u0915 \u0930\u0916\u0930\u0916\u093e\u0935 \u0905\u0902\u0924\u0930\u093e\u0932 \u092a\u0930, \u0914\u0930 \u092c\u093e\u0926 \u092e\u0947\u0902 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 3-5 \u0938\u093e\u0932 \u0915\u0947 \u0905\u0902\u0924\u0930\u093e\u0932 \u092a\u0930 \u092b\u093f\u0930 \u0938\u0947 \u0915\u0938\u0928\u0947 (\u0930\u0947\u091f\u0949\u0930\u094d\u0915) \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b\u0924\u0940 \u0939\u0948\u0964 \u0915\u0902\u092a\u0928, \u0924\u093e\u092a\u0940\u092f \u091a\u0915\u094d\u0930\u0923, \u092f\u093e \u0909\u091a\u094d\u091a-\u0915\u0930\u0902\u091f \u0926\u094b\u0937\u094b\u0902 \u0915\u0947 \u0905\u0927\u0940\u0928 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u0915\u094b \u0905\u0927\u093f\u0915 \u092c\u093e\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u0947 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964 \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u0932\u094b\u0921\u0947\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092a\u0942\u0930\u0940 \u0924\u0930\u0939 \u0938\u0947 \u0930\u0940-\u091f\u0949\u0915\u093f\u0902\u0917 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0915\u094b \u0938\u092e\u093e\u092a\u094d\u0924 \u0915\u0930 \u0926\u0947\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0938\u0938\u0947 \u0935\u0947 \u0909\u0928 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0924\u0947\u091c\u0940 \u0938\u0947 \u092a\u0938\u0902\u0926\u0940\u0926\u093e \u092c\u0928\u0924\u0947 \u091c\u093e \u0930\u0939\u0947 \u0939\u0948\u0902 \u091c\u0939\u093e\u0901 \u0930\u0916\u0930\u0916\u093e\u0935 \u0924\u0915 \u092a\u0939\u0941\u0901\u091a \u092e\u0941\u0936\u094d\u0915\u093f\u0932 \u092f\u093e \u092e\u0939\u0902\u0917\u0940 \u0939\u0948\u0964.<\/p>\n<h3>Q6: \u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u091d\u0947 \u0915\u094c\u0928-\u0915\u094c\u0928 \u0938\u0947 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>\u0906\u0935\u0936\u094d\u092f\u0915 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u0947\u092c\u0932 \u0915\u094b \u0905\u0926\u094d\u0935\u093f\u0924\u0940\u092f \u092a\u0939\u091a\u093e\u0928\u0915\u0930\u094d\u0924\u093e\u0913\u0902, \u091a\u093e\u0932\u0915 \u0930\u0902\u0917\u094b\u0902, \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u0914\u0930 \u0915\u0947\u092c\u0932 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u092a\u0939\u091a\u093e\u0928\u0928\u0947 \u0935\u093e\u0932\u0947 \u0915\u0947\u092c\u0932 \u0905\u0928\u0941\u0938\u0942\u091a\u093f\u092f\u093e\u0901 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964 \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 (\u0915\u0947\u0935\u0932 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0905\u092d\u093f\u092a\u094d\u0930\u093e\u092f \u0928\u0939\u0940\u0902) \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u090f\u091c\u093c-\u092c\u093f\u0932\u094d\u091f \u0930\u0942\u091f\u093f\u0902\u0917 \u0921\u094d\u0930\u0949\u0907\u0902\u0917\u094d\u0938 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902\u0964 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092e\u093e\u092a, \u0928\u093f\u0930\u0902\u0924\u0930\u0924\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u0928 \u092a\u0930\u093f\u0923\u093e\u092e \u0914\u0930 \u0915\u093f\u0938\u0940 \u092d\u0940 \u0936\u0940\u0932\u094d\u0921 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0939\u093f\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0930\u093f\u0915\u0949\u0930\u094d\u0921 \u0938\u0941\u0930\u0915\u094d\u0937\u093f\u0924 \u0930\u0916\u0947\u0902\u0964 \u0905\u0917\u094d\u0928\u093f \u0930\u0947\u091f\u093f\u0902\u0917 \u0914\u0930 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0935\u093f\u0936\u0947\u0937\u0924\u093e\u0913\u0902 \u0915\u0940 \u092a\u0941\u0937\u094d\u091f\u093f \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0921\u0947\u091f\u093e \u0936\u0940\u091f\u094d\u0938 \u0930\u0916\u0947\u0902\u0964 \u092f\u0939 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923, \u0938\u0902\u0936\u094b\u0927\u0928\u094b\u0902 \u0914\u0930 \u0928\u093f\u092f\u093e\u092e\u0915 \u0911\u0921\u093f\u091f \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0905\u0924\u094d\u092f\u0902\u0924 \u092e\u0942\u0932\u094d\u092f\u0935\u093e\u0928 \u0938\u093e\u092c\u093f\u0924 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>Q7: \u092e\u0948\u0902 \u092c\u093e\u0939\u0930\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928\u094d\u0938 \u092a\u0930 \u0928\u092e\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u094b \u0915\u0948\u0938\u0947 \u0930\u094b\u0915\u0942\u0901?<\/h3>\n<p>\u092c\u093e\u0939\u0930\u0940 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u0909\u091a\u093f\u0924 IP (\u0907\u0902\u0917\u094d\u0930\u0947\u0936 \u092a\u094d\u0930\u094b\u091f\u0947\u0915\u094d\u0936\u0928) \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0915\u0947\u092c\u0932 \u0917\u094d\u0932\u0948\u0902\u0921 \u0915\u093e \u091a\u092f\u0928 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u2014\u092c\u093e\u0939\u0930\u0940 MV \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0915\u0947 \u0932\u093f\u090f \u0928\u094d\u092f\u0942\u0928\u0924\u092e IP66\u0964 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u0915\u0947\u092c\u0932 \u092a\u094d\u0930\u0935\u0947\u0936 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u092a\u0930 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0938\u0940\u0932\u0947\u0902\u091f \u0932\u0917\u093e\u090f\u0901\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u090f\u0928\u0915\u094d\u0932\u094b\u091c\u0930 \u092e\u0947\u0902 \u0909\u091a\u093f\u0924 \u0928\u093f\u0915\u093e\u0938\u0940 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e (\u0928\u093f\u091a\u0932\u0947 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u092a\u0930 \u0935\u0940\u092a \u0939\u094b\u0932) \u092c\u0928\u0940 \u0930\u0939\u0947, \u0928 \u0915\u093f \u0939\u0930\u094d\u092e\u0947\u091f\u093f\u0915 \u0938\u0940\u0932\u093f\u0902\u0917 \u0915\u093e \u092a\u094d\u0930\u092f\u093e\u0938 \u0915\u0930\u0947\u0902, \u091c\u094b \u0905\u0928\u093f\u0935\u093e\u0930\u094d\u092f \u0930\u0942\u092a \u0938\u0947 \u0935\u093f\u092b\u0932 \u0939\u094b \u091c\u093e\u0924\u0940 \u0939\u0948\u0964 \u0926\u092c\u093e\u0935 \u0915\u094b \u0938\u0902\u0924\u0941\u0932\u093f\u0924 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u092c\u094d\u0930\u0940\u0926\u093f\u0902\u0917 \u090f\u0932\u093f\u092e\u0947\u0902\u091f\u094d\u0938 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902, \u091c\u094b \u0928\u092e\u0940 \u0915\u0947 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0941\u090f \u0926\u092c\u093e\u0935 \u0915\u094b \u092c\u0930\u093e\u092c\u0930 \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0910\u0938\u0947 \u091c\u0947\u0932-\u092d\u0930\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094d\u0938 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0947\u0902 \u091c\u094b \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0938\u0947 \u0928\u092e\u0940 \u0915\u094b \u092c\u093e\u0939\u0930 \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<hr \/>\n<h2>\u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937: \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u0916\u094d\u092f \u092c\u093f\u0902\u0926\u0941<\/h2>\n<p>\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u0915\u0947 \u091a\u092f\u0928 \u092e\u0947\u0902 \u0915\u0908 \u092a\u0930\u0938\u094d\u092a\u0930 \u0928\u093f\u0930\u094d\u092d\u0930 \u0915\u093e\u0930\u0915\u094b\u0902 \u092a\u0930 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948, \u091c\u094b \u0938\u093e\u092e\u0942\u0939\u093f\u0915 \u0930\u0942\u092a \u0938\u0947 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0914\u0930 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0928\u093f\u0930\u094d\u0923\u092f\u094b\u0902 \u0915\u093e \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u0928 \u0915\u0930\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<\/p>\n<p><strong>\u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u093e \u091a\u092f\u0928 \u0935\u093f\u0926\u094d\u092f\u0941\u0924-\u091a\u0941\u0902\u092c\u0915\u0940\u092f \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0938\u0947 \u092e\u0947\u0932 \u0916\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f\u0964.<\/strong> \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0938\u094d\u0930\u094b\u0924\u094b\u0902 \u0915\u094b \u0938\u092e\u091d\u0947\u0902, \u0938\u093f\u0917\u094d\u0928\u0932 \u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932\u0924\u093e \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0947\u0902, \u0914\u0930 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0936\u0940\u0932\u094d\u0921 \u092a\u094d\u0930\u0915\u093e\u0930 \u0924\u0925\u093e \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0935\u093f\u0927\u093f\u092f\u094b\u0902 \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0947\u0902\u0964 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u0915\u094b \u0905\u0927\u093f\u0915-\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u093e \u0936\u093e\u092f\u0926 \u0939\u0940 \u0915\u092d\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u092a\u0948\u0926\u093e \u0915\u0930\u0924\u093e \u0939\u0948; \u0915\u092e-\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u093e \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u092e\u0947\u0902 \u0926\u0941\u0903\u0938\u094d\u0935\u092a\u094d\u0928 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<p><strong>\u0906\u0917 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0938\u0902\u092c\u0902\u0927\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 \u0914\u0930 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u093e\u0927\u093f\u0915\u093e\u0930 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u092d\u093f\u0928\u094d\u0928 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964.<\/strong> \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u094d\u0925\u093e\u0928, \u0932\u093e\u0917\u0942 \u0915\u094b\u0921\u094b\u0902 \u0914\u0930 \u092a\u0930\u093f\u0923\u093e\u092e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0906\u0917 \u0915\u0947 \u092a\u094d\u0930\u0938\u093e\u0930, \u0905\u0917\u094d\u0928\u093f\u0930\u094b\u0927\u0940 \u0915\u094d\u0937\u092e\u0924\u093e, \u0927\u0941\u0906\u0901 \u0909\u0924\u094d\u0938\u0930\u094d\u091c\u0928 \u0914\u0930 \u0939\u0948\u0932\u094b\u091c\u0928 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0947\u0902\u0964   \u0916\u094b\u091c \u090f\u0935\u0902 \u0926\u092e\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0938\u0939\u093f\u0924 \u0938\u092e\u0917\u094d\u0930 \u0905\u0917\u094d\u0928\u093f \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u0923\u0928\u0940\u0924\u093f \u0915\u0947 \u0938\u093e\u0925 \u0905\u0917\u094d\u0928\u093f \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0915\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0930\u0947\u0902\u0964.<\/p>\n<p><strong>\u0930\u0942\u091f\u093f\u0902\u0917 \u0905\u0928\u0941\u0936\u093e\u0938\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948\u0964.<\/strong> \u0935\u093f\u092d\u093e\u091c\u0928 \u0926\u0942\u0930\u0940 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902, \u092e\u094b\u0921\u093c \u0924\u094d\u0930\u093f\u091c\u094d\u092f\u093e \u0938\u0940\u092e\u093e\u0913\u0902 \u0915\u093e \u092a\u093e\u0932\u0928 \u0915\u0930\u0947\u0902, \u0914\u0930 \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u0938\u092e\u0930\u094d\u0925\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0902\u0964 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0925\u094b\u0921\u093c\u0940 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u092e\u0947\u0939\u0928\u0924 \u0935\u0930\u094d\u0937\u094b\u0902 \u0924\u0915 \u091a\u0932\u0928\u0947 \u0935\u093e\u0932\u0940 \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0914\u0930 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u094b \u0930\u094b\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<p><strong>\u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964.<\/strong> \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092a\u094d\u0930\u0915\u093e\u0930 \u091a\u0941\u0928\u0947\u0902, \u0915\u094d\u0930\u093f\u092e\u094d\u092a\u094d\u0938 \u0915\u094b \u0938\u0939\u0940 \u0922\u0902\u0917 \u0938\u0947 \u0928\u093f\u0937\u094d\u092a\u093e\u0926\u093f\u0924 \u0915\u0930\u0947\u0902, \u0914\u0930 \u092a\u0948\u0928\u0932 \u0938\u0940\u092e\u093e \u0915\u0947 \u092a\u093e\u0930 \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917 \u092a\u094d\u0930\u092d\u093e\u0935\u0936\u0940\u0932\u0924\u093e \u0915\u094b \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u0947 \u0935\u093e\u0932\u0940 \u0936\u0940\u0932\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928 \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902\u0964.<\/p>\n<p><strong>\u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u094b \u092e\u093e\u0928\u094d\u092f \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/strong> \u0938\u094d\u0925\u093e\u092a\u0928\u093e-\u092a\u0942\u0930\u094d\u0935 \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0926\u094b\u0937\u094b\u0902 \u0915\u094b \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0939\u0940 \u092a\u0915\u0921\u093c \u0932\u0947\u0924\u093e \u0939\u0948\u0964 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0947 \u0938\u0902\u0926\u0930\u094d\u092d \u0914\u0930 \u0930\u0941\u091d\u093e\u0928 \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u093f\u0923\u093e\u092e\u094b\u0902 \u0915\u094b \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u093f\u0924 \u0915\u0930\u0947\u0902\u0964.<\/p>\n<p>\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0940 \u0932\u093e\u0917\u0924 \u0915\u093e \u090f\u0915 \u091b\u094b\u091f\u093e \u0938\u093e \u0939\u093f\u0938\u094d\u0938\u093e \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0932\u0947\u0915\u093f\u0928 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u092b\u0932\u0924\u093e \u092a\u0930 \u0909\u0928\u0915\u093e \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092a\u094d\u0930\u092d\u093e\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0927\u094d\u092f\u093e\u0928 \u0914\u0930 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e\u092a\u0942\u0930\u094d\u0923 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0915\u093e \u091a\u092f\u0928 \u0909\u092a\u0915\u0930\u0923 \u0915\u0947 30\u201340 \u0935\u0930\u094d\u0937 \u0915\u0947 \u0938\u0947\u0935\u093e \u091c\u0940\u0935\u0928 \u092d\u0930 \u0932\u093e\u092d \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h2>\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0924\u0915\u0928\u0940\u0915\u0940 \u0938\u0902\u0938\u093e\u0927\u0928<\/h2>\n<ul>\u0906\u0930\u090f\u0928<\/p>\n<li><a href=\"https:\/\/xbrele.com\/hi\/switchgear-component-manufacturers-buyer-guide\/\">\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0918\u091f\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0916\u0930\u0940\u0926\u093e\u0930 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/switchgear\/\">\u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0921\u093f\u091c\u093e\u0907\u0928 \u0915\u0947 \u092e\u0942\u0932 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/\">\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u092a\u0941\u0930\u094d\u091c\u0947 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0918\u091f\u0915<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/vacuum-contactor\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0902\u092a\u0930\u094d\u0915\u093f\u0924\u094d\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0905\u0938\u094d\u0925\u093e\u092f\u0940 \u0935\u093e\u0924\u093e\u0935\u0930\u0923<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/vacuum-circuit-breaker\/\">\u0935\u0948\u0915\u094d\u092f\u0942\u092e \u0938\u0930\u094d\u0915\u093f\u091f \u092c\u094d\u0930\u0947\u0915\u0930 \u092a\u094b\u0930\u094d\u091f\u092b\u094b\u0932\u093f\u092f\u094b<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/99635\" target=\"_blank\" rel=\"noopener\">IEC 62271-100 \u092a\u094d\u0930\u0915\u093e\u0936\u0928 \u092a\u0943\u0937\u094d\u0920<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0936\u0940\u0932\u094d\u0921\u093f\u0902\u0917, \u0905\u0917\u094d\u0928\u093f \u0930\u0947\u091f\u093f\u0902\u0917, \u0930\u093e\u0909\u091f\u093f\u0902\u0917, \u091f\u0930\u094d\u092e\u093f\u0928\u0947\u0936\u0928, \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0914\u0930 \u0908\u090f\u092e\u0938\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091a\u0941\u0928\u0947\u0902\u0964.<\/p>","protected":false},"author":3,"featured_media":3674,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3679","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/3679","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=3679"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/3679\/revisions"}],"predecessor-version":[{"id":4113,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/3679\/revisions\/4113"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/3674"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=3679"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=3679"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=3679"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}