{"id":3691,"date":"2026-05-10T09:00:00","date_gmt":"2026-05-10T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3691"},"modified":"2026-06-18T08:23:55","modified_gmt":"2026-06-18T08:23:55","slug":"terminal-blocks-control-wiring-switchgear-manufacturers","status":"publish","type":"post","link":"https:\/\/xbrele.com\/hi\/terminal-blocks-control-wiring-switchgear-manufacturers\/","title":{"rendered":"\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094d\u0938: \u092c\u094d\u0930\u093e\u0902\u0921, \u0930\u0947\u091f\u093f\u0902\u0917, \u0914\u0930 \u091a\u092f\u0928 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f"},"content":{"rendered":"<h2>\u092a\u0930\u093f\u091a\u092f: \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u092d\u0942\u092e\u093f\u0915\u093e<\/h2>\n<p>\u092e\u0947\u0930\u0947 \u0924\u0947\u0908\u0938 \u0935\u0930\u094d\u0937\u094b\u0902 \u0915\u0947 \u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0938\u093f\u0938\u094d\u091f\u092e\u094b\u0902 \u0915\u0947 \u0921\u093f\u091c\u093e\u0907\u0928 \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0915\u0947 \u0905\u0928\u0941\u092d\u0935 \u092e\u0947\u0902, \u092e\u0948\u0902\u0928\u0947 \u0905\u0928\u0917\u093f\u0928\u0924 \u092a\u0948\u0928\u0932 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 \u0926\u0947\u0916\u0940 \u0939\u0948\u0902 \u091c\u094b \u092a\u094d\u0930\u093e\u0925\u092e\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0924\u0915 \u0928\u0939\u0940\u0902, \u092c\u0932\u094d\u0915\u093f \u0926\u093f\u0916\u0928\u0947 \u092e\u0947\u0902 \u092e\u093e\u092e\u0942\u0932\u0940 \u0918\u091f\u0915\u094b\u0902 \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0925\u0940\u0902: \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915, \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f, \u092b\u0947\u0930\u0942\u0932 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u090f\u0915\u094d\u0938\u0947\u0938\u0930\u0940\u091c\u093c\u0964 \u092f\u0947 \u0918\u091f\u0915, \u0939\u093e\u0932\u093e\u0902\u0915\u093f \u0915\u0941\u0932 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0932\u093e\u0917\u0924 \u0915\u093e \u0936\u093e\u092f\u0926 2\u20135% \u0939\u0940 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0938\u0940\u0927\u0947 \u0924\u094c\u0930 \u092a\u0930 \u0938\u093f\u0938\u094d\u091f\u092e \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e, \u0930\u0916\u0930\u0916\u093e\u0935 \u0926\u0915\u094d\u0937\u0924\u093e \u0914\u0930 \u0926\u0940\u0930\u094d\u0918\u0915\u093e\u0932\u093f\u0915 \u092a\u0930\u093f\u091a\u093e\u0932\u0928 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p>\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0924\u0902\u0924\u094d\u0930\u093f\u0915\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u093f\u0902\u0926\u0941\u0913\u0902 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0915\u093e\u0930\u094d\u092f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902, \u091c\u094b \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947, \u092e\u0940\u091f\u0930\u093f\u0902\u0917 \u0938\u093f\u0938\u094d\u091f\u092e, \u092e\u094b\u091f\u0930 \u0911\u092a\u0930\u0947\u091f\u0930 \u0914\u0930 \u0938\u0902\u091a\u093e\u0930 \u0928\u0947\u091f\u0935\u0930\u094d\u0915 \u0915\u094b \u091c\u094b\u0921\u093c\u0924\u0947 \u0939\u0948\u0902\u0964 \u090f\u0915 \u0905\u0915\u0947\u0932\u093e \u0916\u0930\u093e\u092c \u0930\u0947\u091f\u0947\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092a\u0942\u0930\u0947 \u0938\u092c\u0938\u094d\u091f\u0947\u0936\u0928 \u092e\u0947\u0902 \u0915\u094d\u0930\u092e\u093f\u0915 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0902 \u092a\u0948\u0926\u093e \u0915\u0930 \u0938\u0915\u0924\u093e \u0939\u0948\u0964 \u092e\u0948\u0902\u0928\u0947 \u0905\u092a\u0928\u0947 \u0915\u0930\u093f\u092f\u0930 \u0915\u0940 \u0936\u0941\u0930\u0941\u0906\u0924 \u092e\u0947\u0902 \u0939\u0940 \u092f\u0939 \u0938\u092c\u0915 \u0938\u0940\u0916\u093e, \u091c\u092c \u090f\u0915 \u092a\u0947\u091f\u094d\u0930\u094b\u0915\u0947\u092e\u093f\u0915\u0932 \u0938\u0902\u092f\u0902\u0924\u094d\u0930 \u092e\u0947\u0902 15kV \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0932\u093e\u0907\u0928\u0905\u092a \u092e\u0947\u0902 \u0917\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u0940 \u0932\u0942 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f \u092e\u0947\u0902 \u0916\u0930\u093e\u092c\u0940 \u0906 \u0917\u0908\u2014\u0939\u092e\u093e\u0930\u0947 \u0926\u094d\u0935\u093e\u0930\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094d\u0938 65\u00b0C \u0915\u0947 \u092a\u0930\u093f\u0935\u0947\u0936\u0940 \u0924\u093e\u092a\u092e\u093e\u0928 \u0915\u094b \u0938\u0902\u092d\u093e\u0932 \u0928\u0939\u0940\u0902 \u092a\u093e\u090f\u0964.<\/p>\n<p>\u092f\u0939 \u0935\u094d\u092f\u093e\u092a\u0915 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u093f\u0915\u093e \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915-\u0935\u093f\u0936\u094d\u0935 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0905\u0928\u0941\u092d\u0935, \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0924\u0915\u0928\u0940\u0915\u0940 \u0921\u0947\u091f\u093e \u0914\u0930 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u093e\u0928\u0915\u094b\u0902 \u0938\u0947 \u092a\u094d\u0930\u0947\u0930\u093f\u0924 \u0939\u0948, \u091c\u094b \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u094b\u0902, \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0915\u094b\u0902 \u0914\u0930 \u0916\u0930\u0940\u0926 \u092a\u0947\u0936\u0947\u0935\u0930\u094b\u0902 \u0915\u094b \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0918\u091f\u0915\u094b\u0902 \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0928\u0947 \u092e\u0947\u0902 \u092e\u0926\u0926 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0939\u092e \u092a\u094d\u0930\u092e\u0941\u0916 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u093e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0915\u0930\u0947\u0902\u0917\u0947, \u0938\u094d\u092a\u0937\u094d\u091f \u091a\u092f\u0928 \u092e\u093e\u0928\u0926\u0902\u0921 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902\u0917\u0947, \u0914\u0930 \u0935\u094d\u092f\u093e\u0935\u0939\u093e\u0930\u093f\u0915 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0902\u0917\u0947 \u091c\u093f\u0928\u094d\u0939\u0947\u0902 \u0906\u092a \u0924\u0941\u0930\u0902\u0924 \u0905\u092a\u0928\u0947 \u0905\u0917\u0932\u0947 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u094d\u0930\u094b\u091c\u0947\u0915\u094d\u091f \u092e\u0947\u0902 \u0932\u093e\u0917\u0942 \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear.webp\" alt=\"\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u0914\u0930 \u0938\u094d\u0915\u094d\u0930\u0942-\u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u093e \u0935\u093f\u0938\u094d\u092b\u094b\u091f\u093f\u0924 \u0906\u0930\u0947\u0916\" class=\"wp-image-3687\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u0914\u0930 \u0938\u094d\u0915\u094d\u0930\u0942-\u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u0915\u0940 \u0906\u0902\u0924\u0930\u093f\u0915 \u0938\u0902\u0930\u091a\u0928\u093e \u0915\u0940 \u0924\u0941\u0932\u0928\u093e, \u091c\u093f\u0938\u092e\u0947\u0902 \u0915\u094d\u0932\u0948\u0902\u092a\u093f\u0902\u0917 \u0924\u0902\u0924\u094d\u0930 \u0914\u0930 \u091a\u093e\u0932\u0915 \u0938\u0902\u092a\u0930\u094d\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0926\u093f\u0916\u093e\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n<h2>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u092e\u0947\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0918\u091f\u0915 \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u094b\u0902 \u0915\u0940 \u0938\u092e\u091d<\/h2>\n<p>\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925 \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 24\u2013250VDC \u092f\u093e 120\u2013240VAC \u092a\u0930 \u0938\u0902\u091a\u093e\u0932\u093f\u0924 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u091c\u093f\u0928\u0915\u0947 \u0932\u093f\u090f \u0907\u0928 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0924\u0930\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921 \u0918\u091f\u0915 \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902, \u0938\u093e\u0925 \u0939\u0940 \u092f\u0947 \u090f\u092e\u0935\u0940 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u092e\u094c\u091c\u0942\u0926 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u091a\u0941\u092e\u094d\u092c\u0915\u0940\u092f \u0939\u0938\u094d\u0924\u0915\u094d\u0937\u0947\u092a \u0914\u0930 \u0924\u093e\u092a\u0940\u092f \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u093e \u0938\u093e\u092e\u0928\u093e \u0915\u0930 \u0938\u0915\u0924\u0947 \u0939\u094b\u0902\u0964.<\/p>\n<h3>\u092e\u0941\u0916\u094d\u092f \u0918\u091f\u0915 \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u093e\u0901<\/h3>\n<p><strong>\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094d\u0938<\/strong> \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u094b\u0902 \u0915\u093e \u0906\u0927\u093e\u0930 \u092c\u0928\u093e\u0924\u0947 \u0939\u0948\u0902\u0964 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u0939\u092e \u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<br \/>\n\u2013 <strong>\u092b\u0940\u0921-\u0925\u094d\u0930\u0942 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/strong> \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u0938\u0902\u0915\u0947\u0924 \u0914\u0930 \u092a\u093e\u0935\u0930 \u0935\u093f\u0924\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f<br \/>\n\u2013 <strong>\u092b\u094d\u092f\u0942\u091c\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094d\u0938<\/strong> \u0938\u0940\u091f\u0940 \u0914\u0930 \u092a\u0940\u091f\u0940 \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u0940 \u0938\u0941\u0930\u0915\u094d\u0937\u093e<br \/>\n\u2013 <strong>\u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u094b \u0905\u0932\u0917 \u0915\u0930\u0947\u0902<\/strong> \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0938\u0915\u094d\u0937\u092e \u0915\u0930\u0928\u093e<br \/>\n\u2013 <strong>\u092d\u0942\u092e\u093f \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/strong> \u0909\u091a\u093f\u0924 \u092c\u093e\u0902\u0921\u093f\u0902\u0917 \u0914\u0930 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0917\u094d\u0930\u093e\u0909\u0902\u0921\u093f\u0902\u0917 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0928\u093e<br \/>\n\u2013 <strong>\u0938\u0947\u0902\u0938\u0930\/\u090f\u0915\u094d\u091a\u0941\u090f\u091f\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/strong> \u0938\u092e\u0938\u094d\u092f\u093e \u0928\u093f\u0935\u093e\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u090f\u0915\u0940\u0915\u0943\u0924 \u090f\u0932\u0908\u0921\u0940 \u0938\u0902\u0915\u0947\u0924\u0915<\/p>\n<p><strong>\u0924\u093e\u0930 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0918\u091f\u0915<\/strong> \u0936\u093e\u092e\u093f\u0932 \u0915\u0930\u0947\u0902:<br \/>\n\u2013 \u0938\u094d\u0932\u0949\u091f\u0947\u0921 \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f (\u092a\u0948\u0902\u0921\u094d\u092f\u0942\u0907\u091f-\u0936\u0948\u0932\u0940 \u092f\u093e \u0938\u092e\u0915\u0915\u094d\u0937)<br \/>\n\u2013 \u0938\u094d\u092a\u093e\u0907\u0930\u0932 \u0930\u0948\u092a \u0914\u0930 \u092c\u0941\u0928\u0940 \u0939\u0941\u0908 \u0938\u094d\u0932\u0940\u0935\u093f\u0902\u0917<br \/>\n\u2013 \u0915\u0947\u092c\u0932 \u091f\u093e\u0908 \u0914\u0930 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u092c\u0947\u0938<br \/>\n\u2013 \u0915\u0902\u0921\u094d\u092f\u0942\u0907\u091f \u092b\u093f\u091f\u093f\u0902\u0917\u094d\u0938 \u0914\u0930 \u0932\u093f\u0915\u094d\u0935\u093f\u0921-\u091f\u093e\u0907\u091f \u0915\u0928\u0947\u0915\u094d\u091f\u0930\u094d\u0938<\/p>\n<p>\u0909\u0938\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923-\u092a\u0948\u0928\u0932 BOM \u0938\u092e\u0940\u0915\u094d\u0937\u093e \u092e\u0947\u0902, <a href=\"https:\/\/shieldhz.com\/\" target=\"_blank\" rel=\"noopener\">\u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0918\u091f\u0915<\/a> \u091c\u0948\u0938\u0947 \u0915\u093f \u0938\u0947\u0932\u0947\u0915\u094d\u091f\u0930 \u0938\u094d\u0935\u093f\u091a, \u0907\u0902\u0921\u093f\u0915\u0947\u091f\u0930 \u0932\u0948\u0902\u092a, \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u0921\u093f\u0935\u093e\u0907\u0938, \u0914\u0930 \u0938\u0939\u093e\u092f\u0915 \u0938\u0902\u092a\u0930\u094d\u0915, \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0914\u0930 \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f \u0915\u0947 \u0938\u093e\u0925 \u092e\u093f\u0932\u0915\u0930 \u091c\u093e\u0901\u091a\u0947 \u091c\u093e\u0928\u0947 \u091a\u093e\u0939\u093f\u090f, \u0915\u094d\u092f\u094b\u0902\u0915\u093f \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0932\u0947\u0906\u0909\u091f \u0914\u0930 \u0911\u092a\u0930\u0947\u091f\u0930 \u0907\u0902\u091f\u0930\u092b\u093c\u0947\u0938 \u0915\u0947 \u0935\u093f\u0915\u0932\u094d\u092a \u090f\u0915-\u0926\u0942\u0938\u0930\u0947 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<p><strong>\u092a\u0939\u091a\u093e\u0928 \u0914\u0930 \u0905\u0902\u0915\u0928 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/strong> \u0938\u092e\u0947\u091f\u0928\u093e:<br \/>\n\u2013 \u092a\u0939\u0932\u0947 \u0938\u0947 \u091b\u092a\u0947 \u0924\u093e\u0930 \u092e\u093e\u0930\u094d\u0915\u0930<br \/>\n\u2013 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0932\u0947\u092c\u0932<br \/>\n\u2013 \u0915\u0947\u092c\u0932 \u091f\u0948\u0917 \u0914\u0930 \u092b\u0947\u0930\u0942\u0932<br \/>\n\u2013 \u0932\u0947\u091c\u093c\u0930-\u092a\u094d\u0930\u093f\u0902\u091f \u0915\u0930\u0928\u0947 \u092f\u094b\u0917\u094d\u092f \u0932\u0947\u092c\u0932\u093f\u0902\u0917 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear.webp\" alt=\"\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f \u0936\u0940\u0930\u094d\u0937 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0924\u093e\u0932\u093f\u0915\u093e, \u091c\u093f\u0938\u092e\u0947\u0902 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0930\u0947\u0902\u091c, \u0915\u0930\u0902\u091f \u0930\u0947\u091f\u093f\u0902\u0917 \u0914\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092a\u094d\u0930\u0915\u093e\u0930 \u0926\u093f\u0916\u093e\u090f \u0917\u090f \u0939\u0948\u0902\u0964\" class=\"wp-image-3688\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u092a\u093e\u0901\u091a \u092a\u094d\u0930\u092e\u0941\u0916 \u0909\u0924\u094d\u092a\u093e\u0926 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e\u0913\u0902 \u092e\u0947\u0902 \u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0924\u0941\u0932\u0928\u093e \u092e\u0948\u091f\u094d\u0930\u093f\u0915\u094d\u0938\u0964.<\/figcaption><\/figure>\n<h2>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0936\u0940\u0930\u094d\u0937 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e<\/h2>\n<h3>\u092b\u0940\u0928\u093f\u0915\u094d\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f<\/h3>\n<p>Phoenix Contact \u0935\u093f\u0936\u094d\u0935\u092d\u0930 \u092e\u0947\u0902 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u092e\u0947\u0902 \u0932\u0917\u093e\u0924\u093e\u0930 \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e \u0935\u093f\u0915\u0932\u094d\u092a \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u0928 \u092c\u0928\u093e\u0924\u093e \u0939\u0948\u0964 \u0909\u0928\u0915\u093e CLIPLINE \u092a\u0942\u0930\u094d\u0923 \u0938\u093f\u0938\u094d\u091f\u092e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948:<\/p>\n<ul>\n<li><strong>\u092f\u0942\u0915\u0947 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> 1000V\/125A \u0924\u0915 \u0930\u0947\u091f\u0947\u0921 \u092b\u0940\u0921-\u0925\u094d\u0930\u0942 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n<li><strong>\u092f\u0942\u091f\u0940 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u091b\u094b\u091f\u0947 \u092a\u0926\u091a\u093f\u0939\u094d\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0935\u093e\u0932\u0947 \u0909\u091a\u094d\u091a-\u0918\u0928\u0924\u094d\u0935 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<li><strong>\u092a\u0940\u091f\u0940-\u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u092a\u0941\u0936-\u0907\u0928 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0924\u0915\u0928\u0940\u0915 \u091c\u094b \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u092e\u092f \u0915\u094b \u0932\u0917\u092d\u0917 50% \u0924\u0915 \u0915\u092e \u0915\u0930\u0924\u0940 \u0939\u0948\u0964<\/li>\n<li><strong>\u0935\u094d\u092f\u093e\u092a\u0915 \u092a\u094d\u0930\u092e\u093e\u0923\u0928 \u092a\u094b\u0930\u094d\u091f\u092b\u094b\u0932\u093f\u092f\u094b<\/strong> UL 1059, CSA, ATEX, \u0914\u0930 IECEx \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u0938\u0939\u093f\u0924<\/li>\n<\/ul>\n<p>\u0921\u0947\u091f\u093e \u0938\u0947\u0902\u091f\u0930 \u0915\u0947 \u0932\u093f\u090f \u0939\u093e\u0932 \u0939\u0940 \u092e\u0947\u0902 \u090f\u0915 15kV \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u092e\u0947\u0902, \u0939\u092e\u0928\u0947 \u092a\u0942\u0930\u0947 \u092a\u094d\u0930\u094b\u091c\u0947\u0915\u094d\u091f \u092e\u0947\u0902 Phoenix Contact \u0915\u0947 PTIO \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u092f\u093e\u0964 \u091f\u0942\u0932-\u092b\u094d\u0930\u0940 \u092a\u0941\u0936-\u0907\u0928 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0914\u0930 \u091f\u0947\u0938\u094d\u091f\/\u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u092b\u093c\u0902\u0915\u094d\u0936\u0928 \u0915\u0947 \u0938\u0902\u092f\u094b\u091c\u0928 \u0938\u0947 \u0939\u092e\u093e\u0930\u0940 \u092a\u0948\u0928\u0932 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0915\u093e \u0938\u092e\u092f \u092a\u094d\u0930\u0924\u093f \u0932\u093e\u0907\u0928\u0938\u0947\u0915\u094d\u0936\u0928 18 \u0918\u0902\u091f\u0947 \u0938\u0947 \u0918\u091f\u0915\u0930 \u0932\u0917\u092d\u0917 11 \u0918\u0902\u091f\u0947 \u0939\u094b \u0917\u092f\u093e\u0964.<\/p>\n<h3>\u0935\u093e\u0907\u0921\u092e\u0941\u0932\u0930<\/h3>\n<p>\u091c\u0930\u094d\u092e\u0928 \u0907\u0902\u091c\u0940\u0928\u093f\u092f\u0930\u093f\u0902\u0917 \u0915\u0940 \u0938\u091f\u0940\u0915\u0924\u093e Weidm\u00fcller \u0915\u0940 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092a\u0947\u0936\u0915\u0936\u094b\u0902 \u0915\u094b \u092a\u0930\u093f\u092d\u093e\u0937\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u0909\u0928\u0915\u0940 KLIPPON Connect \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0940 \u0939\u0948:<\/p>\n<ul>\n<li><strong>\u0938\u094d\u0928\u0948\u092a-\u0907\u0928 \u0924\u0915\u0928\u0940\u0915<\/strong> \u0905\u0902\u0927\u093e\u0927\u0941\u0902\u0927 \u092a\u094d\u0930\u0935\u0947\u0936 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f\u2014\u0938\u0902\u0915\u0940\u0930\u094d\u0923 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f\u094d\u0938 \u092e\u0947\u0902 \u0915\u093e\u092e \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0905\u092e\u0942\u0932\u094d\u092f<\/li>\n<li><strong>\u0921\u092c\u094d\u0932\u094d\u092f\u0942-\u0938\u0940\u0930\u0940\u091c\u093c<\/strong> 2.5-35mm\u00b2 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0915\u094d\u0937\u092e\u0924\u093e \u0935\u093e\u0932\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n<li><strong>\u0935\u094d\u092f\u093e\u092a\u0915 \u0930\u0902\u0917-\u0915\u094b\u0921\u093f\u0902\u0917 \u0935\u093f\u0915\u0932\u094d\u092a<\/strong> IEC 60446 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u093e<\/li>\n<li><strong>\u090f\u0915\u0940\u0915\u0943\u0924 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u0938\u0941\u0935\u093f\u0927\u093e\u090f\u0901<\/strong> \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f-\u0938\u094d\u091f\u093e\u0907\u0932 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u092a\u0930<\/li>\n<\/ul>\n<h3>\u0935\u093e\u0917\u094b<\/h3>\n<p>\u0935\u093e\u0917\u094b \u0928\u0947 \u0905\u092a\u0928\u0940 \u0915\u0947\u091c \u0915\u094d\u0932\u0948\u092e\u094d\u092a \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0924\u0915\u0928\u0940\u0915 \u0938\u0947 \u0909\u0926\u094d\u092f\u094b\u0917 \u092e\u0947\u0902 \u0915\u094d\u0930\u093e\u0902\u0924\u093f \u0932\u093e \u0926\u0940\u0964 \u092a\u094d\u0930\u092e\u0941\u0916 \u0909\u0924\u094d\u092a\u093e\u0926\u094b\u0902 \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902:<\/p>\n<ul>\n<li><strong>\u091f\u0949\u092a\u091c\u0949\u092c \u090f\u0938 \u0938\u0940\u0930\u0940\u091c\u093c<\/strong> \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921<\/li>\n<li><strong>2000 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u0905\u0932\u094d\u091f\u094d\u0930\u093e-\u0915\u0949\u092e\u094d\u092a\u0948\u0915\u094d\u091f 3.5 \u092e\u093f\u092e\u0940 \u0938\u094d\u092a\u0947\u0938\u093f\u0902\u0917 \u0915\u0940 \u092a\u0947\u0936\u0915\u0936<\/li>\n<li><strong>\u092c\u093f\u0928\u093e \u0914\u091c\u093e\u0930 \u0915\u0947 \u0938\u0902\u091a\u093e\u0932\u0928<\/strong> \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u091f\u0949\u0930\u094d\u0915 \u0932\u0917\u093e\u090f \u0917\u090f \u0938\u094d\u0915\u094d\u0930\u0942 \u0938\u0947 \u0939\u094b\u0928\u0947 \u0935\u093e\u0932\u0940 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u0924\u094d\u0930\u0941\u091f\u093f\u092f\u094b\u0902 \u0915\u094b \u0915\u092e \u0915\u0930\u0928\u093e<\/li>\n<li><strong>\u0915\u0902\u092a\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong> \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u0924\u0928\u093e\u0935\u094b\u0902 \u0915\u0947 \u0905\u0927\u0940\u0928 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 \u0905\u0924\u093f\u0906\u0935\u0936\u094d\u092f\u0915 \u0938\u094d\u0915\u094d\u0930\u0942-\u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n<\/ul>\n<h3>\u090f\u092c\u0940\u092c\u0940 \u090f\u0902\u091f\u094d\u0930\u0947\u0932\u0947\u0915<\/h3>\n<p>ABB \u0915\u093e \u090f\u0902\u091f\u0930\u0932\u0947\u0915 \u0921\u093f\u0935\u0940\u091c\u0928 \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u090f\u0915\u0940\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u093f\u090f \u0917\u090f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948:<\/p>\n<ul>\n<li><strong>SNK \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u0909\u091a\u094d\u091a-\u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u0938\u094d\u0915\u094d\u0930\u0942-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n<li><strong>\u090f\u092e\u090f2.5 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u0930\u093f\u0932\u0947 \u092e\u093e\u0930\u094d\u0936\u0932\u093f\u0902\u0917 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0938\u093e\u0927\u093e\u0930\u0923 \u0918\u0928\u0924\u094d\u0935 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<\/li>\n<li><strong>\u0938\u0940\u0927\u0940 \u0938\u0902\u0917\u0924\u0924\u093e<\/strong> ABB \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u093f\u0932\u0947 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925<\/li>\n<\/ul>\n<h3>\u0930\u0949\u0915\u0935\u0947\u0932 \u0911\u091f\u094b\u092e\u0947\u0936\u0928 (\u090f\u0932\u0928-\u092c\u094d\u0930\u093e\u0921\u0932\u0940)<\/h3>\n<p>\u0930\u0949\u0915\u0935\u0947\u0932 \u092a\u094d\u0932\u0947\u091f\u092b\u093c\u0949\u0930\u094d\u092e \u092a\u0930 \u092e\u093e\u0928\u0915\u0940\u0915\u0943\u0924 \u0909\u0924\u094d\u0924\u0930\u0940 \u0905\u092e\u0947\u0930\u093f\u0915\u0940 \u092c\u093e\u091c\u093c\u093e\u0930\u094b\u0902 \u0914\u0930 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f:<\/p>\n<ul>\n<li><strong>\u0967\u096a\u096f\u0968 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u0935\u094d\u092f\u093e\u092a\u0915 UL \u0932\u093f\u0938\u094d\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915<\/li>\n<li><strong>\u092a\u0942\u0930\u094d\u0935-\u0924\u093e\u0930\u093f\u0924 \u0938\u092e\u093e\u0927\u093e\u0928<\/strong> \u092e\u0948\u0926\u093e\u0928 \u092e\u0947\u0902 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u092e\u092f \u0915\u092e \u0915\u0930\u0928\u093e<\/li>\n<li><strong>\u0938\u094d\u091f\u0942\u0921\u093f\u092f\u094b 5000 \u0915\u0947 \u0938\u093e\u0925 \u090f\u0915\u0940\u0915\u0930\u0923<\/strong> \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c\u0940\u0915\u0930\u0923 \u0938\u094d\u0935\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear.webp\" alt=\"\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0930\u093f\u092a\u0925\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930 \u0914\u0930 \u0930\u0947\u091f\u093f\u0902\u0917 \u091a\u092f\u0928 \u0915\u0930\u0928\u0947 \u0939\u0947\u0924\u0941 \u0928\u093f\u0930\u094d\u0923\u092f \u092a\u094d\u0930\u0935\u093e\u0939 \u0906\u0930\u0947\u0916\" class=\"wp-image-3689\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091a\u092f\u0928 \u092b\u094d\u0932\u094b\u091a\u093e\u0930\u094d\u091f, \u091c\u093f\u0938\u092e\u0947\u0902 \u0938\u0930\u094d\u0915\u093f\u091f \u092a\u094d\u0930\u0915\u093e\u0930, \u0927\u093e\u0930\u093e \u0921\u0947\u0930\u0947\u091f\u093f\u0902\u0917, \u0914\u0930 \u0935\u093f\u0936\u0947\u0937 \u0915\u093e\u0930\u094d\u092f \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902\u0964.<\/figcaption><\/figure>\n<h2>\u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f \u0914\u0930 \u0915\u0947\u092c\u0932 \u092a\u094d\u0930\u092c\u0902\u0927\u0928 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923<\/h2>\n<h3>\u092a\u0948\u0902\u0921\u094d\u092f\u0942\u0907\u091f<\/h3>\n<p>Panduit \u0905\u092a\u0928\u0947 \u0915\u0947 \u0938\u093e\u0925 \u0909\u0924\u094d\u0924\u0930\u0940 \u0905\u092e\u0947\u0930\u093f\u0915\u0940 \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f \u092c\u093e\u091c\u093e\u0930 \u092e\u0947\u0902 \u092a\u094d\u0930\u092d\u0941\u0924\u094d\u0935 \u0930\u0916\u0924\u093e \u0939\u0948:<\/p>\n<ul>\n<li><strong>\u091f\u093e\u0907\u092a F\/G\/H \u0938\u094d\u0932\u0949\u091f\u092f\u0941\u0915\u094d\u0924 \u0921\u0915\u094d\u091f<\/strong> \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u0909\u0902\u0917\u0932\u093f\u092f\u094b\u0902 \u0915\u0940 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e\u0913\u0902 \u092e\u0947\u0902<\/li>\n<li><strong>\u092a\u0948\u0902\u0921\u0915\u094d\u091f\u00ae \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0921\u0915\u094d\u091f<\/strong> \u0928\u093f\u0930\u0902\u0924\u0930 \u0938\u094d\u0932\u0949\u091f \u092a\u0948\u091f\u0930\u094d\u0928 \u0915\u0947 \u0938\u093e\u0925<\/li>\n<li><strong>\u092a\u0940\u0935\u0940\u0938\u0940 \u0914\u0930 \u092a\u0940\u0935\u0940\u0921\u0940\u090f\u092b \u0938\u093e\u092e\u0917\u094d\u0930\u0940<\/strong> \u092e\u093e\u0928\u0915 \u0914\u0930 \u0909\u091a\u094d\u091a-\u0924\u093e\u092a\u092e\u093e\u0928 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<li><strong>\u0906\u0935\u0930\u0923 \u092a\u094d\u0930\u0924\u093f\u0927\u093e\u0930\u0923 \u0921\u093f\u091c\u093c\u093e\u0907\u0928<\/strong> \u0906\u0915\u0938\u094d\u092e\u093f\u0915 \u0916\u0941\u0932\u0928\u0947 \u0938\u0947 \u0930\u094b\u0915\u0928\u093e<\/li>\n<\/ul>\n<p>\u092e\u0948\u0902\u0928\u0947 \u092e\u0940\u091f\u0930\u093f\u0902\u0917 \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f\u094d\u0938 \u092e\u0947\u0902 \u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u093f\u0917\u094d\u0928\u0932 \u0930\u093e\u0909\u091f\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 Panduit \u091f\u093e\u0907\u092a G \u0921\u0915\u094d\u091f (\u0938\u0902\u0915\u0940\u0930\u094d\u0923 \u0938\u094d\u0932\u0949\u091f, \u091a\u094c\u0921\u093c\u0940 \u0909\u0902\u0917\u0932\u0940) \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u093f\u092f\u093e \u0939\u0948\u2014\u0938\u0902\u0915\u0940\u0930\u094d\u0923 \u0938\u094d\u0932\u0949\u091f\u094d\u0938 \u0906\u0915\u0938\u094d\u092e\u093f\u0915 \u0924\u093e\u0930 \u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937\u0923 \u0915\u094b \u0930\u094b\u0915\u0924\u0947 \u0939\u0941\u090f \u092d\u0940 \u092a\u0939\u0941\u0902\u091a \u092c\u0928\u093e\u090f \u0930\u0916\u0924\u0947 \u0939\u0948\u0902\u0964.<\/p>\n<h3>\u0939\u0947\u0932\u0930\u092e\u0948\u0928\u091f\u093e\u0907\u091f\u0928<\/h3>\n<p>\u0939\u0947\u0932\u0930\u092e\u0948\u0928\u091f\u093e\u0907\u091f\u0928 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0947 \u0938\u093e\u0925 \u0905\u0938\u093e\u0927\u093e\u0930\u0923 \u092e\u0942\u0932\u094d\u092f \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948:<\/p>\n<ul>\n<li><strong>\u090f\u091a\u091f\u0940\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u0921\u0940 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u092e\u0947\u091f\u094d\u0930\u093f\u0915 \u0914\u0930 \u0907\u092e\u094d\u092a\u0940\u0930\u093f\u092f\u0932 \u0906\u0915\u093e\u0930\u094b\u0902 \u092e\u0947\u0902 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0921\u0915\u094d\u091f<\/li>\n<li><strong>\u0909\u091a\u094d\u091a-\u0938\u094d\u0932\u0949\u091f \u0918\u0928\u0924\u094d\u0935 \u0935\u093f\u0915\u0932\u094d\u092a<\/strong> \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923-\u092a\u094d\u0930\u0927\u093e\u0928 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<li><strong>\u0939\u0948\u0932\u094b\u091c\u0928-\u092e\u0941\u0915\u094d\u0924 \u0938\u093e\u092e\u0917\u094d\u0930\u0940<\/strong> EN 50642 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u093e<\/li>\n<\/ul>\n<h3>\u0907\u092c\u094b\u0915\u094b (\u092a\u0942\u0930\u094d\u0935 \u092e\u0947\u0902 \u091f\u09401 \u0917\u094d\u0930\u0941\u092a)<\/h3>\n<p>\u092f\u0942\u0930\u094b\u092a\u0940\u092f \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0905\u0915\u094d\u0938\u0930 Iboco \u0909\u0924\u094d\u092a\u093e\u0926\u094b\u0902 \u0915\u094b \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n<ul>\n<li><strong>\u0938\u0940\u0921\u0940-\u090f\u091a\u090f\u092b \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u0906\u0917 \u0938\u0947 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u093e \u0939\u0948\u0932\u094b\u091c\u0928-\u092e\u0941\u0915\u094d\u0924 \u0921\u0915\u094d\u091f<\/li>\n<li><strong>\u0924\u094d\u0935\u0930\u093f\u0924-\u0938\u094d\u0925\u093e\u092a\u0928 \u0906\u0927\u093e\u0930 \u092a\u094d\u0930\u0923\u093e\u0932\u093f\u092f\u093e\u0901<\/strong> \u092a\u0948\u0928\u0932 \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0938\u092e\u092f \u0915\u092e \u0915\u0930\u0928\u093e<\/li>\n<li><strong>\u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0940 \u0935\u093f\u0938\u094d\u0924\u0943\u0924 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u0915\u094b\u0928\u094b\u0902, \u091f\u094d\u0930\u093e\u0902\u091c\u093c\u093f\u0936\u0928\u094d\u0938 \u0914\u0930 \u090f\u0902\u0921 \u0915\u0948\u092a\u094d\u0938 \u0938\u0939\u093f\u0924<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel.webp\" alt=\"\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f \u0915\u093e \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928 \u0906\u0930\u0947\u0916, \u091c\u093f\u0938\u092e\u0947\u0902 \u090f\u0938\u0940, \u0921\u0940\u0938\u0940 \u0914\u0930 \u0938\u093f\u0917\u094d\u0928\u0932 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0926\u093f\u0916\u093e\u092f\u093e \u0917\u092f\u093e \u0939\u0948\u0964\" class=\"wp-image-3690\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f \u0915\u0947 \u0905\u0902\u0926\u0930 \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f \u0930\u0942\u091f\u093f\u0902\u0917 \u0932\u0947\u0906\u0909\u091f, \u091c\u094b \u090f\u0938\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0921\u0940\u0938\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0914\u0930 \u090f\u0928\u093e\u0932\u0949\u0917 \u0938\u093f\u0917\u094d\u0928\u0932 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u0915\u094b \u0926\u0930\u094d\u0936\u093e\u0924\u093e \u0939\u0948\u0964.<\/figcaption><\/figure>\n<h2>\u0906\u0932\u094b\u091a\u0928\u093e\u0924\u094d\u092e\u0915 \u091a\u092f\u0928 \u092e\u093e\u0928\u0926\u0902\u0921 \u0914\u0930 \u0924\u0915\u0928\u0940\u0915\u0940 \u091c\u093e\u0901\u091a-\u0938\u0942\u091a\u0940<\/h2>\n<h3>\u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938<\/h3>\n<p>\u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u0915\u094b \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0924\u0947 \u0938\u092e\u092f, \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th>\n<th>\u0928\u094d\u092f\u0942\u0928\u0924\u092e \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e<\/th>\n<th>\u0905\u0928\u0941\u0936\u0902\u0938\u093f\u0924 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0935\u094b\u0932\u094d\u091f\u0947\u091c<\/td>\n<td>300V (UL) \/ 500V (IEC)<\/td>\n<td>600V (UL) \/ 800V (IEC)<\/td>\n<\/tr>\n<tr>\n<td>\u092e\u093e\u092a\u093e \u0917\u092f\u093e \u0935\u0930\u094d\u0924\u092e\u093e\u0928<\/td>\n<td>\u0938\u0930\u094d\u0915\u093f\u091f \u0905\u0927\u093f\u0915\u0924\u092e \u00d7 1.25<\/td>\n<td>\u0938\u0930\u094d\u0915\u093f\u091f \u0905\u0927\u093f\u0915\u0924\u092e \u00d7 1.5<\/td>\n<\/tr>\n<tr>\n<td>\u0936\u0949\u0930\u094d\u091f-\u0938\u0930\u094d\u0915\u093f\u091f \u0930\u0947\u091f\u093f\u0902\u0917<\/td>\n<td>\u0905\u092a\u0938\u094d\u091f\u094d\u0930\u0940\u092e \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0915\u0947 \u0938\u093e\u0925 \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0930\u0947\u0902<\/td>\n<td>\u092e\u0948\u091a \u092c\u094d\u0930\u0947\u0915\u0930\/\u092b\u094d\u092f\u0942\u091c \u0932\u0947-\u0925\u094d\u0930\u0942<\/td>\n<\/tr>\n<tr>\n<td>\u0906\u0935\u0947\u0917 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/td>\n<td>2.5kV \u0928\u094d\u092f\u0942\u0928\u0924\u092e<\/td>\n<td>\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 4kV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0935\u093f\u091a\u093e\u0930<\/h3>\n<p>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u0905\u0928\u0942\u0920\u0940 \u091a\u0941\u0928\u094c\u0924\u093f\u092f\u093e\u0901 \u092a\u094d\u0930\u0938\u094d\u0924\u0941\u0924 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n<p><strong>\u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938<\/strong> \u0915\u094b \u091c\u093f\u092e\u094d\u092e\u0947\u0926\u093e\u0930 \u0920\u0939\u0930\u093e\u0928\u093e \u091a\u093e\u0939\u093f\u090f:<br \/>\n\u2013 \u092a\u0930\u093f\u0935\u0947\u0936 \u0915\u093e \u0924\u093e\u092a\u092e\u093e\u0928 (\u0905\u0915\u094d\u0938\u0930 IEEE C37.20.2 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 40\u00b0C)<br \/>\n\u2013 \u0906\u0902\u0924\u0930\u093f\u0915 \u0924\u093e\u092a\u092e\u093e\u0928 \u092e\u0947\u0902 \u0935\u0943\u0926\u094d\u0927\u093f (\u0906\u092e\u0924\u094c\u0930 \u092a\u0930 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 15-25\u00b0C)<br \/>\n\u2013 \u0906\u0938\u0928\u094d\u0928 \u0909\u092a\u0915\u0930\u0923 \u0938\u0947 \u090a\u0937\u094d\u092e\u093e \u0915\u093e \u092f\u094b\u0917\u0926\u093e\u0928<\/p>\n<p>\u092e\u0930\u0941\u0938\u094d\u0925\u0932\u0940\u092f \u091c\u0932\u0935\u093e\u092f\u0941 \u092e\u0947\u0902 \u092c\u093e\u0939\u0930\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f, \u092e\u0948\u0902\u0928\u0947 105\u00b0C \u092a\u0930 \u0928\u093f\u0930\u0902\u0924\u0930 \u0938\u0902\u091a\u093e\u0932\u0928 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u0947\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u093e \u091a\u092f\u0928 \u0915\u093f\u092f\u093e \u0939\u0948\u2014\u092e\u093e\u0928\u0915 85\u00b0C \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 2\u20133 \u0935\u0930\u094d\u0937\u094b\u0902 \u0915\u0947 \u092d\u0940\u0924\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0915\u093e \u0915\u093e\u0930\u0923 \u092c\u0928\u0947\u0902\u0917\u0947\u0964.<\/p>\n<p><strong>\u0915\u0902\u092a\u0928 \u0914\u0930 \u091d\u091f\u0915\u093e \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927<\/strong> \u0915\u0947 \u0932\u093f\u090f \u092e\u093e\u092e\u0932\u0947:<br \/>\n\u2013 \u092d\u0942\u0915\u0902\u092a\u0940\u092f \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917 (\u0906\u0908\u0908\u0908\u0908 693 \u092f\u094b\u0917\u094d\u092f\u0924\u093e)<br \/>\n\u2013 \u0918\u0942\u092e\u0928\u0947 \u0935\u093e\u0932\u0940 \u092e\u0936\u0940\u0928\u0930\u0940 \u0915\u0947 \u092a\u093e\u0938 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928<br \/>\n\u2013 \u092e\u094b\u092c\u093e\u0907\u0932 \u092f\u093e \u092a\u0930\u093f\u0935\u0939\u0928\u0940\u092f \u0909\u092a-\u0938\u094d\u091f\u0947\u0936\u0928<\/p>\n<h3>\u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u091a\u092f\u0928<\/h3>\n<p><strong>\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u0940 \u092c\u0949\u0921\u0940:<\/strong><br \/>\n\u2013 <strong>\u092a\u0949\u0932\u0940\u0905\u092e\u093e\u0907\u0921 (PA6.6)<\/strong> \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u092f\u093e\u0902\u0924\u094d\u0930\u093f\u0915 \u092e\u091c\u092c\u0942\u0924\u0940 \u0914\u0930 \u0924\u093e\u092a\u092e\u093e\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948\u0964<br \/>\n\u2013 <strong>\u092a\u0949\u0932\u0940\u0915\u093e\u0930\u094d\u092c\u094b\u0928\u0947\u091f<\/strong> \u0909\u0924\u094d\u0915\u0943\u0937\u094d\u091f \u0906\u0918\u093e\u0924 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u0932\u0947\u0915\u093f\u0928 \u0915\u092e \u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938\u0964<br \/>\n\u2013 <strong>\u0938\u093f\u0930\u0947\u092e\u093f\u0915<\/strong> \u0905\u0924\u094d\u092f\u0927\u093f\u0915 \u0909\u091a\u094d\u091a-\u0924\u093e\u092a\u092e\u093e\u0928 \u092f\u093e \u0906\u0917-\u0938\u0902\u092c\u0902\u0927\u0940 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915<\/p>\n<p><strong>\u0935\u0930\u094d\u0924\u092e\u093e\u0928 \u092c\u093e\u0930 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915:<\/strong><br \/>\n\u2013 <strong>\u092a\u0940\u0924\u0932<\/strong> \u092e\u0927\u094d\u092f\u092e \u0932\u093e\u0917\u0924 \u092a\u0930 \u0905\u091a\u094d\u091b\u0940 \u091a\u093e\u0932\u0915\u0924\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948<br \/>\n\u2013 <strong>\u0924\u093e\u0902\u092c\u093e<\/strong> \u0909\u091a\u094d\u091a-\u0927\u093e\u0930\u093e \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0906\u0935\u0936\u094d\u092f\u0915<br \/>\n\u2013 <strong>\u091f\u093f\u0928 \u092f\u093e \u0928\u093f\u0915\u0932 \u092a\u094d\u0932\u0947\u099f\u09bf\u0982<\/strong> \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0935\u093e\u0924\u093e\u0935\u0930\u0923 \u092e\u0947\u0902 \u0938\u0902\u0915\u094d\u0937\u093e\u0930\u0923 \u0915\u094b \u0930\u094b\u0915\u0924\u093e \u0939\u0948<\/p>\n<h3>\u092a\u094d\u0930\u092e\u093e\u0923\u0940\u0915\u0930\u0923 \u0914\u0930 \u0905\u0928\u0941\u092a\u093e\u0932\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u090f\u0901<\/h3>\n<p>\u0939\u092e\u0947\u0936\u093e \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902:<br \/>\n\u2013 <strong>\u092f\u0942\u090f\u0932 1059<\/strong> \u0909\u0924\u094d\u0924\u0930\u0940 \u0905\u092e\u0947\u0930\u093f\u0915\u0940 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0932\u093f\u0938\u094d\u091f\u093f\u0902\u0917<br \/>\n\u2013 <strong>\u0906\u0908\u0908\u0938\u0940 60947-7-1<\/strong> \u0905\u0902\u0924\u0930\u094d\u0930\u093e\u0937\u094d\u091f\u094d\u0930\u0940\u092f \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e\u0913\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u092a\u093e\u0932\u0928<br \/>\n\u2013 <strong>\u0938\u0940\u090f\u0938\u090f \u092a\u094d\u0930\u092e\u093e\u0923\u0928<\/strong> \u0915\u0928\u093e\u0921\u093e\u0908 \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e\u092a\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<br \/>\n\u2013 <strong>\u090f\u091f\u0940\u0908\u090f\u0915\u094d\u0938\/\u0906\u0908\u0908\u0938\u0940\u090f\u0915\u094d\u0938<\/strong> \u0916\u0924\u0930\u0928\u093e\u0915 \u0915\u094d\u0937\u0947\u0924\u094d\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0930\u0947\u091f\u093f\u0902\u0917<br \/>\n\u2013 <strong>\u092f\u0942\u090f\u0932 508\u090f<\/strong> \u0914\u0926\u094d\u092f\u094b\u0917\u093f\u0915 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0905\u0928\u0941\u092a\u093e\u0932\u0928<\/p>\n<hr \/>\n<h2>\u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e\u090f\u0901 \u0914\u0930 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0935\u093f\u091a\u093e\u0930<\/h2>\n<h3>\u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901<\/h3>\n<p>\u0938\u0948\u0915\u0921\u093c\u094b\u0902 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u094d\u092e\u093e\u0923 \u0915\u0930\u0928\u0947 \u0915\u0947 \u092c\u093e\u0926, \u092e\u0948\u0902\u0928\u0947 \u092f\u0947 \u0938\u093f\u0926\u094d\u0927 \u0935\u094d\u092f\u0935\u0938\u094d\u0925\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u092a\u094d\u0930\u0925\u093e\u090f\u0901 \u0935\u093f\u0915\u0938\u093f\u0924 \u0915\u0940 \u0939\u0948\u0902:<\/p>\n<p><strong>\u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0938\u092e\u0942\u0939\u0915\u0930\u0923:<\/strong><br \/>\n1. \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u0915\u093e\u0930\u094d\u092f (\u0938\u0941\u0930\u0915\u094d\u0937\u093e, \u092e\u0940\u091f\u0930\u093f\u0902\u0917, \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923, \u0938\u0902\u091a\u093e\u0930) \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u094b \u0938\u092e\u0942\u0939\u093f\u0924 \u0915\u0930\u0947\u0902\u0964<br \/>\n2. \u090f\u0938\u0940 \u0914\u0930 \u0921\u0940\u0938\u0940 \u0938\u0930\u094d\u0915\u093f\u091f \u0915\u0947 \u092c\u0940\u091a \u0905\u0932\u0917\u093e\u0935 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902 (\u0928\u094d\u092f\u0942\u0928\u0924\u092e 50 \u092e\u093f\u092e\u0940 \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936 \u0915\u0940 \u091c\u093e\u0924\u0940 \u0939\u0948)<br \/>\n3. \u0905\u0915\u094d\u0938\u0930 \u0909\u092a\u092f\u094b\u0917 \u0915\u093f\u090f \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u0930\u0940\u0915\u094d\u0937\u0923 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u094b \u090f\u0930\u094d\u0917\u094b\u0928\u094b\u092e\u093f\u0915 \u090a\u0901\u091a\u093e\u0907\u092f\u094b\u0902 \u092a\u0930 \u0930\u0916\u0947\u0902\u0964<\/p>\n<p><strong>\u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0906\u0935\u0902\u091f\u0928:<\/strong><br \/>\n\u2013 \u092d\u0935\u093f\u0937\u094d\u092f \u0915\u0947 \u0938\u0902\u0936\u094b\u0927\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f 15-20% \u0938\u094d\u092a\u0947\u092f\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0947\u0902<br \/>\n\u2013 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u093e\u0930\u094d\u092f\u093e\u0924\u094d\u092e\u0915 \u0905\u0928\u0941\u092d\u093e\u0917 \u0915\u0947 \u0905\u0902\u0924 \u092e\u0947\u0902 \u0938\u092e\u0942\u0939 \u0938\u094d\u092a\u0947\u092f\u0930<br \/>\n\u0905\u0928\u0927\u093f\u0915\u0943\u0924 \u0909\u092a\u092f\u094b\u0917 \u0915\u094b \u0930\u094b\u0915\u0928\u0947 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u092a\u0947\u092f\u0930 \u092a\u0930 \u092a\u0939\u0932\u0947 \u0938\u0947 \u201cSPARE\u201d \u0932\u0947\u092c\u0932 \u0932\u0917\u093e\u090f\u0901\u0964<\/p>\n<h3>\u091f\u0949\u0930\u094d\u0915 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0914\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e<\/h3>\n<p>\u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0935\u093f\u092b\u0932\u0924\u093e\u090f\u0901 \u0905\u0915\u094d\u0938\u0930 \u0917\u0932\u0924 \u091f\u0949\u0930\u094d\u0915 \u0915\u0947 \u0915\u093e\u0930\u0923 \u0939\u094b\u0924\u0940 \u0939\u0948\u0902\u0964 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0915\u0930\u0947\u0902 \u0914\u0930 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u0915\u093e \u0906\u0915\u093e\u0930 (AWG)<\/th>\n<th>\u0906\u092e \u091f\u0949\u0930\u094d\u0915 (\u092a\u093e\u0909\u0902\u0921-\u0907\u0902\u091a)<\/th>\n<th>\u0906\u092e \u091f\u0949\u0930\u094d\u0915 (\u0928\u094d\u092f\u0942\u091f\u0928-\u092e\u0940\u091f\u0930)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>18-16<\/td>\n<td>4.4-5.3<\/td>\n<td>0.5-0.6<\/td>\n<\/tr>\n<tr>\n<td>14-12<\/td>\n<td>7.1-8.8<\/td>\n<td>0.8-1.0<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>17.7-22.1<\/td>\n<td>2.0-2.5<\/td>\n<\/tr>\n<tr>\n<td>8-6<\/td>\n<td>26.5-35.4<\/td>\n<td>3.0-4.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u092a\u094d\u0930\u094b \u091f\u093f\u092a: \u0915\u0948\u0932\u093f\u092c\u094d\u0930\u0947\u091f\u0947\u0921 \u091f\u0949\u0930\u094d\u0915 \u0938\u094d\u0915\u094d\u0930\u0942\u0921\u094d\u0930\u093e\u0907\u0935\u0930\u094d\u0938 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902 \u0914\u0930 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u092a\u0902\u091a \u0932\u093f\u0938\u094d\u091f\u094d\u0938 \u092e\u0947\u0902 \u091f\u0949\u0930\u094d\u0915 \u092e\u093e\u0928 \u0926\u0930\u094d\u091c \u0915\u0930\u0947\u0902\u0964 \u092e\u0948\u0902\u0928\u0947 \u0930\u093f\u0938\u0940\u0935\u093f\u0902\u0917 \u0928\u093f\u0930\u0940\u0915\u094d\u0937\u0923 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936 \u0938\u0947 30\u201340% \u0915\u092e \u091f\u0949\u0930\u094d\u0915 \u092e\u093e\u0928 \u092a\u093e\u090f \u091c\u093e\u0928\u0947 \u092a\u0930 \u092a\u0942\u0930\u0947 \u092a\u0948\u0928\u0932 \u0936\u093f\u092a\u092e\u0947\u0902\u091f\u094d\u0938 \u0915\u094b \u0905\u0938\u094d\u0935\u0940\u0915\u093e\u0930 \u0915\u0930 \u0926\u093f\u092f\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u0924\u093e\u0930 \u092b\u0947\u0930\u0942\u0932 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917<\/h3>\n<p>\u092b\u0947\u0930\u0942\u0932 \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u092c\u0939\u0941-\u0924\u0928\u094d\u0924\u0941 \u091a\u093e\u0932\u0915\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u092e\u0947\u0902 \u0928\u093e\u091f\u0915\u0940\u092f \u0930\u0942\u092a \u0938\u0947 \u0938\u0941\u0927\u093e\u0930 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n<ul>\n<li><strong>\u0939\u092e\u0947\u0936\u093e \u092b\u0947\u0930\u0942\u0932 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902\u0964<\/strong> \u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u0914\u0930 \u092a\u0941\u0936-\u0907\u0928 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925<\/li>\n<li><strong>\u092b\u0947\u0930\u0942\u0932\u094b\u0902 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902<\/strong> \u092c\u0939\u0941-\u0924\u0928\u094d\u0924\u0941 \u0924\u093e\u0930 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0915\u094d\u0930\u0942-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u091f\u0930\u094d\u092e\u093f\u0928\u0932<\/li>\n<li><strong>\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u091f\u0947\u0921 \u092b\u0947\u0930\u0941\u0932 \u091a\u0941\u0928\u0947\u0902<\/strong> \u0905\u0928\u0941\u0930\u0942\u092a \u091a\u093e\u0932\u0915 \u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917<\/li>\n<li><strong>\u092b\u0947\u0930\u0942\u0932\u094b\u0902 \u0915\u094b \u0930\u0902\u0917-\u0915\u094b\u0921\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong> \u0924\u094d\u0935\u0930\u093f\u0924 \u0906\u0915\u093e\u0930 \u092a\u0939\u091a\u093e\u0928 \u0915\u0947 \u0932\u093f\u090f \u0921\u0940\u0906\u0908\u090f\u0928 46228-4 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930<\/li>\n<\/ul>\n<hr \/>\n<h2>\u0932\u093e\u0917\u0924-\u0932\u093e\u092d \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923 \u0914\u0930 \u0916\u0930\u0940\u0926 \u0930\u0923\u0928\u0940\u0924\u093f\u092f\u093e\u0901<\/h2>\n<h3>\u0938\u094d\u0935\u093e\u092e\u093f\u0924\u094d\u0935 \u0915\u0940 \u0915\u0941\u0932 \u0932\u093e\u0917\u0924 \u0915\u093e \u092a\u0930\u093f\u092a\u094d\u0930\u0947\u0915\u094d\u0937\u094d\u092f<\/h3>\n<p>\u091c\u092c\u0915\u093f \u0938\u093e\u092e\u093e\u0928\u094d\u092f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092a\u094d\u0930\u0940\u092e\u093f\u092f\u092e \u092c\u094d\u0930\u093e\u0902\u0921\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902 40-60% \u0915\u092e \u0932\u093e\u0917\u0924 \u0935\u093e\u0932\u0947 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902:<\/p>\n<p><strong>\u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0935\u093f\u092b\u0932\u0924\u093e \u0932\u093e\u0917\u0924\u0947\u0902:<\/strong><br \/>\n\u2013 \u0905\u0928\u093f\u092f\u094b\u091c\u093f\u0924 \u0906\u0909\u091f\u0947\u091c \u0935\u094d\u092f\u092f (\u0917\u0902\u092d\u0940\u0930 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u092e\u0947\u0902 \u092a\u094d\u0930\u0924\u093f \u0918\u0902\u091f\u0947 $10,000-$100,000+)<br \/>\n\u2013 \u0906\u092a\u093e\u0924\u0915\u093e\u0932\u0940\u0928 \u0938\u0947\u0935\u093e \u0915\u0949\u0932 \u0936\u0941\u0932\u094d\u0915<br \/>\n\u2013 \u092a\u094d\u0930\u0924\u093f\u0938\u094d\u0925\u093e\u092a\u0928 \u092a\u0941\u0930\u094d\u091c\u094b\u0902 \u0915\u0940 \u0924\u094d\u0935\u0930\u093f\u0924 \u0936\u093f\u092a\u093f\u0902\u0917<\/p>\n<p><strong>\u0905\u092a\u094d\u0930\u0924\u094d\u092f\u0915\u094d\u0937 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0932\u093e\u0917\u0924\u0947\u0902:<\/strong><br \/>\n\u2013 \u0918\u091f\u0915\u094b\u0902 \u0915\u0940 \u0905\u0938\u0902\u0917\u0924 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0915\u0947 \u0915\u093e\u0930\u0923 \u092c\u0922\u093c\u0940 \u0939\u0941\u0908 \u0915\u092e\u0940\u0936\u0928\u093f\u0902\u0917 \u0905\u0935\u0927\u093f<br \/>\n\u2013 \u0909\u091a\u094d\u091a \u0935\u093e\u0930\u0902\u091f\u0940 \u0926\u093e\u0935\u093e \u0926\u0930\u0947\u0902<br \/>\n\u2013 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u0940\u092f \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e \u0915\u094b \u0928\u0941\u0915\u0938\u093e\u0928<\/p>\n<p>\u090f\u0915 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u092e\u0947\u0902, \u0939\u092e\u0928\u0947 \u0905\u0928\u0941\u092e\u093e\u0928 \u0932\u0917\u093e\u092f\u093e \u0915\u093f 15 kV, 8-\u0916\u0902\u0921 \u0932\u093e\u0907\u0928\u0905\u092a \u0915\u0947 \u0932\u093f\u090f Phoenix Contact \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u094b \u090f\u0915 \u0915\u092e-\u0932\u093e\u0917\u0924 \u0935\u093f\u0915\u0932\u094d\u092a \u0915\u0947 \u092c\u091c\u093e\u092f \u091a\u0941\u0928\u0928\u0947 \u0938\u0947 \u0938\u093e\u092e\u0917\u094d\u0930\u0940 \u0932\u093e\u0917\u0924 \u092e\u0947\u0902 $3,200 \u0915\u0940 \u0935\u0943\u0926\u094d\u0927\u093f \u0939\u0941\u0908\u0964 \u0909\u0938\u0940 \u092a\u0930\u093f\u092f\u094b\u091c\u0928\u093e \u0928\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u0947 25-\u0935\u0930\u094d\u0937\u0940\u092f \u091c\u0940\u0935\u0928\u0915\u093e\u0932 \u092e\u0947\u0902 \u0938\u0902\u092d\u093e\u0935\u093f\u0924 \u0935\u093f\u092b\u0932\u0924\u093e \u0932\u093e\u0917\u0924\u094b\u0902 \u092e\u0947\u0902 \u0905\u0928\u0941\u092e\u093e\u0928\u093f\u0924 $180,000 \u0915\u0940 \u092c\u091a\u0924 \u0915\u0940\u0964.<\/p>\n<h3>\u0925\u094b\u0915 \u0916\u0930\u0940\u0926 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930<\/h3>\n<p>\u092c\u0921\u093c\u0947 \u092a\u094d\u0930\u094b\u091c\u0947\u0915\u094d\u091f\u094d\u0938 \u092f\u093e \u091a\u0932 \u0930\u0939\u0947 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u093e\u0930\u094d\u092f\u0915\u094d\u0930\u092e\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f:<\/p>\n<ul>\n<li>\u0938\u0941\u0938\u0902\u0917\u0924 \u092e\u0942\u0932\u094d\u092f \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u092b\u094d\u0930\u0947\u092e\u0935\u0930\u094d\u0915 \u0938\u092e\u091d\u094c\u0924\u094b\u0902 \u092a\u0930 \u092c\u093e\u0924\u091a\u0940\u0924 \u0915\u0930\u0947\u0902\u0964<\/li>\n<li>\u0905\u0928\u0941\u0915\u0942\u0932\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u090f\u0915 \u0939\u0940 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0915\u0947 \u0907\u0915\u094b\u0938\u093f\u0938\u094d\u091f\u092e \u0915\u093e \u092e\u093e\u0928\u0915\u0940\u0915\u0930\u0923 \u0915\u0930\u0947\u0902\u0964<\/li>\n<li>\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0926\u094d\u0935\u093e\u0930\u093e \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0940 \u0917\u0908 \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0938\u0947\u0935\u093e\u0913\u0902 \u0914\u0930 \u0938\u0949\u092b\u093c\u094d\u091f\u0935\u0947\u092f\u0930 \u091f\u0942\u0932 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902\u0964<\/li>\n<li>\u0938\u094d\u0925\u093e\u0928\u0940\u092f \u0907\u0928\u094d\u0935\u0947\u0902\u091f\u0930\u0940 \u0914\u0930 \u0921\u093f\u0932\u0940\u0935\u0930\u0940 \u0915\u094d\u0937\u092e\u0924\u093e\u0913\u0902 \u0915\u093e \u092e\u0942\u0932\u094d\u092f\u093e\u0902\u0915\u0928 \u0915\u0930\u0947\u0902<\/li>\n<\/ul>\n<hr \/>\n<h2>\u0909\u092d\u0930\u0924\u0940 \u092a\u094d\u0930\u094c\u0926\u094d\u092f\u094b\u0917\u093f\u0915\u093f\u092f\u093e\u0901 \u0914\u0930 \u092d\u0935\u093f\u0937\u094d\u092f \u0938\u0902\u092c\u0902\u0927\u0940 \u0935\u093f\u091a\u093e\u0930<\/h2>\n<h3>\u0938\u094d\u092e\u093e\u0930\u094d\u091f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094d\u0938<\/h3>\n<p>\u0915\u0908 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0905\u092c \u090f\u0915\u0940\u0915\u0943\u0924 \u092c\u0941\u0926\u094d\u0927\u093f\u092e\u0924\u094d\u0924\u093e \u0935\u093e\u0932\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902:<\/p>\n<ul>\n<li><strong>\u092b\u093f\u0928\u093f\u0915\u094d\u0938 \u0915\u0949\u0928\u094d\u091f\u0948\u0915\u094d\u091f \u0915\u0940 \u092a\u0940\u091f\u0940\u0938\u0940\u092c\u0940 \u0936\u094d\u0930\u0943\u0902\u0916\u0932\u093e<\/strong> \u090f\u0915\u0940\u0915\u0943\u0924 \u0915\u0930\u0902\u091f \u091f\u094d\u0930\u093e\u0902\u0938\u092b\u0949\u0930\u094d\u092e\u0930\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925<\/li>\n<li><strong>\u0935\u093e\u0917\u094b \u0915\u0947 I\/O \u0938\u093f\u0938\u094d\u091f\u092e<\/strong> \u092a\u0940\u090f\u0932\u0938\u0940 \u0915\u0928\u0947\u0915\u094d\u091f\u093f\u0935\u093f\u091f\u0940 \u0915\u0947 \u0938\u093e\u0925 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u093e \u0938\u0902\u092f\u094b\u091c\u0928<\/li>\n<li><strong>\u0938\u094d\u0925\u093f\u0924\u093f \u0928\u093f\u0917\u0930\u093e\u0928\u0940 \u0915\u094d\u0937\u092e\u0924\u093e\u090f\u0901<\/strong> \u0922\u0940\u0932\u0947 \u0915\u0928\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u092f\u093e \u0905\u0927\u093f\u0915 \u0917\u0930\u094d\u092e \u0939\u094b\u0928\u0947 \u0915\u093e \u092a\u0924\u093e \u0932\u0917\u093e\u0928\u093e<\/li>\n<\/ul>\n<h3>\u0907\u0902\u0921\u0938\u094d\u091f\u094d\u0930\u0940 4.0 \u090f\u0915\u0940\u0915\u0930\u0923<\/h3>\n<p>\u0906\u0927\u0941\u0928\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 \u0926\u093f\u0928-\u092a\u094d\u0930\u0924\u093f\u0926\u093f\u0928 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u092c\u0922\u093c\u0924\u0940 \u091c\u093e \u0930\u0939\u0940 \u0939\u0948:<br \/>\n\u2013 \u092a\u094d\u0930\u094b\u091f\u0947\u0915\u094d\u0936\u0928 \u0930\u093f\u0932\u0947 \u0915\u0947 \u0932\u093f\u090f \u0907\u0902\u0921\u0938\u094d\u091f\u094d\u0930\u093f\u092f\u0932 \u0908\u0925\u0930\u0928\u0947\u091f \u0915\u0928\u0947\u0915\u094d\u091f\u093f\u0935\u093f\u091f\u0940<br \/>\n\u2013 \u0938\u0902\u091a\u093e\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092b\u093e\u0907\u092c\u0930 \u0911\u092a\u094d\u091f\u093f\u0915 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915<br \/>\n\u2013 \u0908\u090f\u092e\u0906\u0908-\u0938\u0902\u0935\u0947\u0926\u0928\u0936\u0940\u0932 \u0938\u0902\u0915\u0947\u0924\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0936\u0940\u0932\u094d\u0921 \u0915\u093f\u090f \u0939\u0941\u090f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0938\u093f\u0938\u094d\u091f\u092e<\/p>\n<p>\u092c\u093e\u0939\u0930\u0940 \u0938\u0902\u0926\u0930\u094d\u092d: IEEE \u0938\u094d\u091f\u0948\u0902\u0921\u0930\u094d\u0921\u094d\u0938 \u090f\u0938\u094b\u0938\u093f\u090f\u0936\u0928 \u0905\u092a\u0928\u0947 IEEE C37.2 \u092e\u093e\u0928\u0915 \u092e\u0947\u0902 \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u0936\u0915\u094d\u0924\u093f \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0909\u092a\u0915\u0930\u0923 \u0915\u093e\u0930\u094d\u092f \u0938\u0902\u0916\u094d\u092f\u093e\u0913\u0902 \u0914\u0930 \u0938\u0902\u092a\u0930\u094d\u0915 \u0928\u093e\u092e\u0915\u0930\u0923 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u092a\u094d\u0930\u0925\u093e\u0913\u0902 \u092a\u0930 \u0935\u094d\u092f\u093e\u092a\u0915 \u092e\u093e\u0930\u094d\u0917\u0926\u0930\u094d\u0936\u0928 \u092a\u094d\u0930\u0926\u093e\u0928 \u0915\u0930\u0924\u093e \u0939\u0948, \u091c\u094b \u0938\u0940\u0927\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0915\u0947 \u0932\u0947\u092c\u0932\u093f\u0902\u0917 \u0914\u0930 \u0938\u0902\u0917\u0920\u0928 \u0915\u094b \u092a\u094d\u0930\u092d\u093e\u0935\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0948\u0964.<\/p>\n<hr \/>\n<h2>\u0905\u0915\u094d\u0938\u0930 \u092a\u0942\u091b\u0947 \u091c\u093e\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u094d\u0930\u0936\u094d\u0928<\/h2>\n<h3>\u092a\u094d\u0930\u0936\u094d\u0928 1: 5A CT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u091d\u0947 \u0915\u094c\u0928 \u0938\u0940 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0927\u093e\u0930\u093e \u0930\u0947\u091f\u093f\u0902\u0917 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u0940 \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>CT \u0926\u094d\u0935\u093f\u0924\u0940\u092f\u0915 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f, \u092e\u0948\u0902 \u0928\u094d\u092f\u0942\u0928\u0924\u092e 10A \u0928\u093f\u0930\u0902\u0924\u0930 \u0930\u0947\u091f\u0947\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u0940 \u0938\u093f\u092b\u093e\u0930\u093f\u0936 \u0915\u0930\u0924\u093e \u0939\u0942\u0901, \u0935\u0930\u0940\u092f\u0924\u093e 15\u201320A \u0915\u0940\u0964 \u0907\u0938\u0938\u0947 \u0935\u094d\u092f\u0935\u0927\u093e\u0928\u094b\u0902 \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u0926\u094b\u0937 \u0927\u093e\u0930\u093e \u0915\u0947 \u092f\u094b\u0917\u0926\u093e\u0928 \u0915\u0947 \u0932\u093f\u090f \u092a\u0930\u094d\u092f\u093e\u092a\u094d\u0924 \u092e\u093e\u0930\u094d\u091c\u093f\u0928 \u092e\u093f\u0932\u0924\u093e \u0939\u0948\u0964 \u0905\u0927\u093f\u0915 \u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923 \u0930\u0942\u092a \u0938\u0947, CT \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0936\u0949\u0930\u094d\u091f\u093f\u0902\u0917-\u091f\u093e\u0907\u092a \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0947\u0902 \u091c\u094b \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f \u0939\u094b\u0928\u0947 \u0938\u0947 \u092a\u0939\u0932\u0947 \u0938\u094d\u0935\u091a\u093e\u0932\u093f\u0924 \u0930\u0942\u092a \u0938\u0947 \u0936\u0949\u0930\u094d\u091f \u0915\u0930 \u0926\u0947\u0902\u2014\u0907\u0938\u0938\u0947 \u0916\u0924\u0930\u0928\u093e\u0915 \u0916\u0941\u0932\u0947-\u0938\u0930\u094d\u0915\u093f\u091f CT \u0935\u094b\u0932\u094d\u091f\u0947\u091c, \u091c\u094b \u0915\u0908 \u0939\u091c\u093e\u0930 \u0935\u094b\u0932\u094d\u091f \u0924\u0915 \u0939\u094b \u0938\u0915\u0924\u0947 \u0939\u0948\u0902, \u0938\u0947 \u092c\u091a\u093e\u0935 \u0939\u094b\u0924\u093e \u0939\u0948\u0964.<\/p>\n<h3>\u092a\u094d\u0930\u0936\u094d\u0928 2: \u0915\u094d\u092f\u093e \u092e\u0948\u0902 \u090f\u0915 \u0939\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u0948\u0928\u0932 \u092e\u0947\u0902 \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u094b \u092e\u093f\u0932\u093e \u0938\u0915\u0924\u093e \u0939\u0942\u0901?<\/h3>\n<p>\u0939\u093e\u0932\u093e\u0902\u0915\u093f DIN \u0930\u0947\u0932 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u0924\u0915\u0928\u0940\u0915\u0940 \u0930\u0942\u092a \u0938\u0947 \u0938\u0902\u092d\u0935 \u0939\u0948, \u092e\u0948\u0902 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u094b \u092e\u093f\u0932\u093e\u0928\u0947 \u0915\u0940 \u0926\u0943\u0922\u093c\u0924\u093e \u0938\u0947 \u0938\u0932\u093e\u0939 \u0928\u0939\u0940\u0902 \u0926\u0947\u0924\u093e\u0964 \u0935\u093f\u092d\u093f\u0928\u094d\u0928 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092a\u0930\u093f\u0935\u093e\u0930\u094b\u0902 \u0915\u0947 \u092a\u093e\u0938 \u0905\u0932\u0917-\u0905\u0932\u0917 \u0938\u0939\u093e\u092f\u0915 \u0909\u092a\u0915\u0930\u0923, \u0932\u0947\u092c\u0932\u093f\u0902\u0917 \u0938\u093f\u0938\u094d\u091f\u092e \u0914\u0930 \u091c\u092e\u094d\u092a\u0930 \u0935\u093f\u0928\u094d\u092f\u093e\u0938 \u0939\u094b\u0924\u0947 \u0939\u0948\u0902\u0964 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0930\u094d\u092e\u093f\u092f\u094b\u0902 \u0915\u094b \u0915\u0908 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u092a\u0941\u0930\u094d\u091c\u0947 \u0938\u094d\u091f\u0949\u0915 \u0915\u0930\u0928\u0947 \u092a\u0921\u093c\u0924\u0947 \u0939\u0948\u0902\u0964 \u090f\u0915 \u0938\u0941\u0935\u093f\u0927\u093e \u0911\u0921\u093f\u091f \u092e\u0947\u0902, \u092e\u0948\u0902\u0928\u0947 \u092c\u093e\u0930\u0939 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0938\u0947\u0915\u094d\u0936\u0928\u094b\u0902 \u092e\u0947\u0902 \u0938\u093e\u0924 \u0905\u0932\u0917-\u0905\u0932\u0917 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092c\u094d\u0930\u093e\u0902\u0921 \u092a\u093e\u090f\u2014\u091c\u093f\u0938\u0938\u0947 \u0907\u0928\u094d\u0935\u0947\u0902\u091f\u0930\u0940 \u092e\u0947\u0902 \u0926\u0941\u0903\u0938\u094d\u0935\u092a\u094d\u0928 \u0914\u0930 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0938\u0902\u0917\u0924\u0924\u093e \u0938\u0902\u092c\u0902\u0927\u0940 \u0938\u092e\u0938\u094d\u092f\u093e\u090f\u0901 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0939\u0941\u0908\u0902\u0964.<\/p>\n<h3>\u092a\u094d\u0930\u0936\u094d\u0928 3: \u092e\u0948\u0902 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0924\u093e\u0930 \u0921\u0915\u094d\u091f \u092d\u0930\u093e\u0908 \u0905\u0928\u0941\u092a\u093e\u0924 \u0915\u0948\u0938\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0942\u0901?<\/h3>\n<p>\u0909\u0926\u094d\u092f\u094b\u0917 \u0915\u0940 \u0938\u0930\u094d\u0935\u094b\u0924\u094d\u0924\u092e \u092a\u094d\u0930\u0925\u093e \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0935\u093e\u092f\u0930 \u0921\u0915\u094d\u091f \u092d\u0930\u093e\u0908 \u0915\u094b \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928\u0932 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u092b\u0932 \u0915\u0947 40\u201350% \u0924\u0915 \u0938\u0940\u092e\u093f\u0924 \u0915\u0930\u0924\u0940 \u0939\u0948\u0964 \u092f\u0939 \u092d\u0935\u093f\u0937\u094d\u092f \u092e\u0947\u0902 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u0924\u093e\u0930 \u091c\u094b\u0921\u093c\u0928\u0947 \u0915\u0940 \u0905\u0928\u0941\u092e\u0924\u093f \u0926\u0947\u0924\u093e \u0939\u0948 \u0914\u0930 \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0915\u0947 \u0926\u094c\u0930\u093e\u0928 \u091a\u093e\u0932\u0915 \u0915\u094b \u0915\u094d\u0937\u0924\u093f \u0938\u0947 \u092c\u091a\u093e\u0924\u093e \u0939\u0948\u0964 \u0917\u0930\u094d\u092e\u0940 \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u092a\u093e\u0935\u0930 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092d\u0930\u093e\u0908 \u0915\u094b 30\u201335% \u0924\u0915 \u0915\u092e \u0915\u0930\u0947\u0902\u0964 \u092e\u0948\u0902 \u0921\u0915\u094d\u091f \u0915\u093e \u0906\u0915\u093e\u0930 \u091a\u093e\u0932\u0915 \u0915\u0947 \u0915\u094d\u0930\u0949\u0938-\u0938\u0947\u0915\u094d\u0936\u0928\u0932 \u0915\u094d\u0937\u0947\u0924\u094d\u0930\u092b\u0932 (\u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0938\u0939\u093f\u0924) \u0915\u094b \u091c\u094b\u0921\u093c\u0915\u0930 \u0914\u0930 \u0909\u0938\u0947 0.4 \u0938\u0947 \u0935\u093f\u092d\u093e\u091c\u093f\u0924 \u0915\u0930\u0915\u0947 \u0928\u093f\u0930\u094d\u0927\u093e\u0930\u093f\u0924 \u0915\u0930\u0924\u093e \u0939\u0942\u0901\u0964.<\/p>\n<h3>Q4: \u092c\u093e\u0939\u0930\u0940 \u092a\u0948\u0921-\u092e\u093e\u0909\u0902\u091f\u0947\u0921 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092e\u0947\u0902 \u0909\u092a\u092f\u094b\u0917 \u0915\u0947 \u0932\u093f\u090f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u092e\u0947\u0902 \u0915\u094c\u0928 \u0938\u0947 \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u0939\u094b\u0928\u0947 \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>\u092c\u093e\u0939\u0930\u0940 \u090f\u092e\u0935\u0940 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f, \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u0915\u093e \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0947\u0902:<br \/>\n\u2013 \u0906\u0909\u091f\u0921\u094b\u0930 \u0909\u092a\u092f\u094b\u0917 \u092e\u093e\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u0947 \u0938\u093e\u0925 \u092f\u0942\u090f\u0932 1059<br \/>\n\u2013 \u0928\u094d\u092f\u0942\u0928\u0924\u092e IP20 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0930\u0947\u091f\u093f\u0902\u0917 (\u0916\u0941\u0932\u0947 \u0938\u094d\u0925\u093e\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f IP67)<br \/>\n\u2013 \u0905\u092a\u0947\u0915\u094d\u0937\u093f\u0924 \u092a\u0930\u093f\u0935\u0947\u0936\u0940\u092f \u0924\u093e\u092a\u092e\u093e\u0928 \u0914\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u0935\u0943\u0926\u094d\u0927\u093f \u0938\u0939\u093f\u0924 \u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917<br \/>\n\u2013 \u0927\u0942\u092a \u0915\u0947 \u0938\u0902\u092a\u0930\u094d\u0915 \u092e\u0947\u0902 \u0906\u0928\u0947 \u092a\u0930 \u092f\u0942\u0935\u0940-\u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927\u0940 \u0938\u093e\u092e\u0917\u094d\u0930\u0940<br \/>\n\u2013 \u0924\u091f\u0940\u092f \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e\u092a\u0928\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u091f\u0947\u0928\u0932\u0947\u0938 \u0938\u094d\u091f\u0940\u0932 \u092f\u093e \u0935\u093f\u0936\u0947\u0937 \u0930\u0942\u092a \u0938\u0947 \u0932\u0947\u092a\u093f\u0924 \u0939\u093e\u0930\u094d\u0921\u0935\u0947\u092f\u0930 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902\u0964<\/p>\n<h3>Q5: \u0915\u094d\u092f\u093e \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0905\u0928\u0941\u092a\u094d\u0930\u092f\u094b\u0917\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u092a\u0941\u0936-\u0907\u0928 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0938\u094d\u0935\u0940\u0915\u093e\u0930\u094d\u092f \u0939\u0948\u0902, \u092f\u093e \u092e\u0941\u091d\u0947 \u0938\u094d\u0915\u094d\u0930\u0942-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u092a\u094d\u0930\u0915\u093e\u0930 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0928\u0947 \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>\u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093f\u0924 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u0913\u0902 \u0915\u0947 \u092a\u0941\u0936-\u0907\u0928 (\u0938\u094d\u092a\u094d\u0930\u093f\u0902\u0917-\u0915\u0947\u091c) \u091f\u0930\u094d\u092e\u093f\u0928\u0932, \u0938\u0939\u0940 \u0924\u0930\u0940\u0915\u0947 \u0938\u0947 \u0932\u0917\u093e\u090f \u091c\u093e\u0928\u0947 \u092a\u0930, \u0938\u094d\u0915\u094d\u0930\u0942-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u0915\u0940 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f\u0924\u093e \u0915\u094b \u092a\u0942\u0930\u093e \u0915\u0930\u0924\u0947 \u0939\u0948\u0902 \u092f\u093e \u0909\u0938\u0938\u0947 \u092c\u0947\u0939\u0924\u0930 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u0915\u0930\u0924\u0947 \u0939\u0948\u0902\u0964 \u092e\u0941\u0916\u094d\u092f \u0932\u093e\u092d\u094b\u0902 \u092e\u0947\u0902 \u0936\u093e\u092e\u093f\u0932 \u0939\u0948\u0902: \u090f\u0915\u0938\u092e\u093e\u0928 \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u092c\u0932, \u0915\u0902\u092a\u0928 \u092a\u094d\u0930\u0924\u093f\u0930\u094b\u0927, \u0914\u0930 \u0924\u0947\u091c\u093c \u0938\u094d\u0925\u093e\u092a\u0928\u093e\u0964 \u0938\u0941\u0928\u093f\u0936\u094d\u091a\u093f\u0924 \u0915\u0930\u0947\u0902 \u0915\u093f \u0935\u093f\u0936\u093f\u0937\u094d\u091f \u092a\u0941\u0936-\u0907\u0928 \u092e\u0949\u0921\u0932 \u0906\u092a\u0915\u0947 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 \u092a\u094d\u0930\u0915\u093e\u0930 (\u0938\u0949\u0932\u093f\u0921, \u0938\u094d\u091f\u094d\u0930\u0948\u0902\u0921\u0947\u0921, \u092f\u093e \u092b\u0947\u0930\u0942\u0932 \u0915\u0947 \u0938\u093e\u0925 \u092b\u093e\u0907\u0928-\u0938\u094d\u091f\u094d\u0930\u0948\u0902\u0921\u0947\u0921) \u0915\u0947 \u0932\u093f\u090f \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0939\u094b \u0914\u0930 \u0927\u094d\u092f\u093e\u0928 \u0930\u0916\u0947\u0902 \u0915\u093f \u092c\u0921\u093c\u0947 \u0915\u0902\u0921\u0915\u094d\u091f\u0930 (4 \u092e\u093f\u092e\u0940\u00b2 \u0938\u0947 \u090a\u092a\u0930) \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0915\u094d\u0930\u0942-\u0915\u094d\u0932\u0948\u092e\u094d\u092a \u0921\u093f\u091c\u093c\u093e\u0907\u0928 \u0915\u0940 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e \u0939\u094b \u0938\u0915\u0924\u0940 \u0939\u0948\u0964.<\/p>\n<h3>Q6: \u092e\u0941\u091d\u0947 MV \u0914\u0930 LV \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f\u094d\u0938 \u0915\u0947 \u092c\u0940\u091a \u0915\u094d\u0930\u0949\u0938 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915\u094b\u0902 \u0915\u094b \u0915\u0948\u0938\u0947 \u0938\u0902\u092d\u093e\u0932\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0916\u0902\u0921\u094b\u0902 \u0915\u0947 \u092c\u0940\u091a \u0938\u0902\u0915\u094d\u0930\u092e\u0923 \u0915\u0930\u0928\u0947 \u0935\u093e\u0932\u0947 \u0938\u0930\u094d\u0915\u093f\u091f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0938\u093e\u0935\u0927\u093e\u0928\u0940\u092a\u0942\u0930\u094d\u0935\u0915 \u0927\u094d\u092f\u093e\u0928 \u0926\u0947\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948:<br \/>\n\u2013 \u0915\u0947\u0935\u0932 \u0928\u093f\u092e\u094d\u0928-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0915\u092e\u094d\u092a\u093e\u0930\u094d\u091f\u092e\u0947\u0902\u091f \u092e\u0947\u0902 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u0938\u094d\u0925\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<br \/>\n\u2013 \u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u0930\u0947\u091f\u093f\u0902\u0917 \u0935\u093e\u0932\u0947 \u092b\u0940\u0921\u0925\u094d\u0930\u0942 \u092c\u0941\u0936\u093f\u0902\u0917 \u092f\u093e \u0905\u0935\u0930\u094b\u0927\u0915 \u0915\u093e \u0909\u092a\u092f\u094b\u0917 \u0915\u0930\u0947\u0902<br \/>\n\u2013 \u0932\u093e\u0917\u0942 \u092e\u093e\u0928\u0915\u094b\u0902 \u0915\u0947 \u0905\u0928\u0941\u0938\u093e\u0930 \u091a\u0930\u0923 \u092a\u0943\u0925\u0915\u094d\u0915\u0930\u0923 \u092c\u0928\u093e\u090f \u0930\u0916\u0947\u0902<br \/>\n\u2013 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0938\u092e\u0928\u094d\u0935\u092f \u0915\u0947 \u0932\u093f\u090f \u092b\u094d\u092f\u0942\u091c\u093c\u094d\u0921 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902<br \/>\n\u2013 \u0938\u094d\u0925\u093e\u092f\u0940 \u0932\u0947\u092c\u0932 \u0915\u0947 \u0938\u093e\u0925 \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0930\u0947\u091f\u093f\u0902\u0917 \u0915\u094b \u0938\u094d\u092a\u0937\u094d\u091f \u0930\u0942\u092a \u0938\u0947 \u0926\u0938\u094d\u0924\u093e\u0935\u0947\u091c\u093c \u0915\u0930\u0947\u0902<\/p>\n<h3>Q7: \u092e\u0941\u091d\u0947 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u0918\u091f\u0915\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0915\u094c\u0928-\u0915\u094c\u0928 \u0938\u0947 \u0938\u094d\u092a\u0947\u092f\u0930 \u092a\u093e\u0930\u094d\u091f\u094d\u0938 \u0915\u093e \u0938\u094d\u091f\u0949\u0915 \u092c\u0928\u093e\u090f \u0930\u0916\u0928\u093e \u091a\u093e\u0939\u093f\u090f?<\/h3>\n<p>\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0938\u0941\u0935\u093f\u0927\u093e\u0913\u0902 \u0915\u0947 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0905\u092a\u0928\u0947 \u0905\u0928\u0941\u092d\u0935 \u0915\u0947 \u0906\u0927\u093e\u0930 \u092a\u0930, \u092e\u0948\u0902 \u0928\u093f\u092e\u094d\u0928\u0932\u093f\u0916\u093f\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0940 \u0938\u0932\u093e\u0939 \u0926\u0942\u0901\u0917\u093e:<br \/>\n\u2013 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092a\u094d\u0930\u0915\u093e\u0930 \u0915\u0947 5% \u0938\u094d\u0925\u093e\u092a\u093f\u0924<br \/>\n\u2013 \u090f\u0915 \u092a\u0942\u0930\u0947 \u0905\u0928\u0941\u092d\u093e\u0917 \u0915\u0947 \u0932\u093f\u090f \u0932\u0947\u092c\u0932\u093f\u0902\u0917\/\u092e\u093e\u0930\u094d\u0915\u093f\u0902\u0917 \u0915\u093e \u092a\u0942\u0930\u093e \u0938\u093e\u092e\u093e\u0928<br \/>\n\u2013 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0935\u093f\u0928\u094d\u092f\u093e\u0938 \u0915\u0947 \u0932\u093f\u090f \u091c\u0902\u092a\u0930\u094d\u0938 \u0914\u0930 \u092c\u094d\u0930\u093f\u091c\u0947\u0938<br \/>\n\u2013 \u090f\u0902\u0921 \u092c\u094d\u0930\u0948\u0915\u0947\u091f, \u0915\u0935\u0930, \u0914\u0930 \u092e\u093e\u0909\u0902\u091f\u093f\u0902\u0917 \u090f\u0915\u094d\u0938\u0947\u0938\u0930\u0940\u091c\u093c<br \/>\n\u2013 \u0935\u093f\u0936\u0947\u0937\u0940\u0915\u0943\u0924 \u091f\u0930\u094d\u092e\u093f\u0928\u0932\u094b\u0902 \u092e\u0947\u0902 \u0938\u0947 \u092a\u094d\u0930\u0924\u094d\u092f\u0947\u0915 \u0915\u093e \u0915\u092e \u0938\u0947 \u0915\u092e \u090f\u0915 (\u092b\u094d\u092f\u0942\u091c\u093c, \u0921\u093f\u0938\u094d\u0915\u0928\u0947\u0915\u094d\u091f, \u0917\u094d\u0930\u093e\u0909\u0902\u0921)<\/p>\n<hr \/>\n<h2>\u0928\u093f\u0937\u094d\u0915\u0930\u094d\u0937: \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u091a\u092f\u0928 \u092e\u0947\u0902 \u0938\u092b\u0932\u0924\u093e \u0915\u0947 \u0932\u093f\u090f \u092e\u0941\u0916\u094d\u092f \u092c\u093f\u0902\u0926\u0941<\/h2>\n<p>\u092e\u0927\u094d\u092f\u092e \u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0918\u091f\u0915\u094b\u0902 \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0924\u0947 \u0938\u092e\u092f \u0935\u093f\u0926\u094d\u092f\u0941\u0924 \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928, \u092a\u0930\u094d\u092f\u093e\u0935\u0930\u0923\u0940\u092f \u0905\u0928\u0941\u0915\u0942\u0932\u0924\u093e, \u0938\u094d\u0925\u093e\u092a\u0928\u093e \u0926\u0915\u094d\u0937\u0924\u093e \u0914\u0930 \u091c\u0940\u0935\u0928\u091a\u0915\u094d\u0930 \u0932\u093e\u0917\u0924 \u0915\u0947 \u092c\u0940\u091a \u0938\u0902\u0924\u0941\u0932\u0928 \u092c\u0928\u093e\u0928\u093e \u0906\u0935\u0936\u094d\u092f\u0915 \u0939\u0948\u0964 \u0907\u0938 \u0917\u093e\u0907\u0921 \u092e\u0947\u0902 \u0909\u0932\u094d\u0932\u093f\u0916\u093f\u0924 \u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e\u2014Phoenix Contact, Weidm\u00fcller, Wago, ABB Entrelec \u0914\u0930 \u0905\u0928\u094d\u092f\u2014\u0928\u0947 \u0928\u093f\u0930\u0902\u0924\u0930 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e \u0914\u0930 \u0935\u094d\u092f\u093e\u092a\u0915 \u0924\u0915\u0928\u0940\u0915\u0940 \u0938\u0939\u093e\u092f\u0924\u093e \u0915\u0947 \u092e\u093e\u0927\u094d\u092f\u092e \u0938\u0947 \u0905\u092a\u0928\u0940 \u092a\u094d\u0930\u0924\u093f\u0937\u094d\u0920\u093e \u0905\u0930\u094d\u091c\u093f\u0924 \u0915\u0940 \u0939\u0948\u0964.<\/p>\n<p><strong>\u092f\u093e\u0926 \u0930\u0916\u0928\u0947 \u092f\u094b\u0917\u094d\u092f \u0906\u0935\u0936\u094d\u092f\u0915 \u091a\u092f\u0928 \u092e\u093e\u0928\u0926\u0902\u0921:<\/strong><\/p>\n<ol>\n<li><strong>\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0914\u0930 \u0927\u093e\u0930\u093e \u0930\u0947\u091f\u093f\u0902\u0917 \u0938\u0924\u094d\u092f\u093e\u092a\u093f\u0924 \u0915\u0930\u0947\u0902<\/strong> \u0905\u092a\u0928\u0940 \u0906\u0935\u0947\u0926\u0928 \u0906\u0935\u0936\u094d\u092f\u0915\u0924\u093e\u0913\u0902 \u0938\u0947 \u0928\u094d\u092f\u0942\u0928\u0924\u092e 25-50% \u0905\u0927\u093f\u0915<\/li>\n<li><strong>\u0924\u093e\u092a\u092e\u093e\u0928 \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938 \u092e\u093f\u0932\u093e\u090f\u0901<\/strong> \u0915\u0947\u0935\u0932 \u092a\u0930\u093f\u0935\u0947\u0936\u0940\u092f \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u0939\u0940\u0902, \u092c\u0932\u094d\u0915\u093f \u0935\u093e\u0938\u094d\u0924\u0935\u093f\u0915 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0906\u0902\u0924\u0930\u093f\u0915 \u092a\u0930\u093f\u0938\u094d\u0925\u093f\u0924\u093f\u092f\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<li><strong>\u090f\u0915\u0932-\u0928\u093f\u0930\u094d\u092e\u093e\u0924\u093e \u0907\u0915\u094b\u0938\u093f\u0938\u094d\u091f\u092e\u094b\u0902 \u0915\u093e \u092e\u093e\u0928\u0915\u0940\u0915\u0930\u0923 \u0915\u0930\u0947\u0902<\/strong> \u0905\u0928\u0941\u0915\u0942\u0932\u0924\u093e \u0914\u0930 \u0938\u0930\u0932\u0940\u0915\u0943\u0924 \u0930\u0916\u0930\u0916\u093e\u0935 \u0915\u0947 \u0932\u093f\u090f<\/li>\n<li><strong>\u0909\u092a\u092f\u0941\u0915\u094d\u0924 \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930 \u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f \u0915\u0930\u0947\u0902<\/strong> \u0906\u092a\u0915\u0947 \u092d\u094c\u0917\u094b\u0932\u093f\u0915 \u0914\u0930 \u0928\u093f\u092f\u093e\u092e\u0915 \u092a\u0930\u093f\u0935\u0947\u0936 \u0915\u0947 \u0932\u093f\u090f (UL, IEC, CSA)<\/li>\n<li><strong>\u0915\u0941\u0932 \u091c\u0940\u0935\u0928\u091a\u0915\u094d\u0930 \u0932\u093e\u0917\u0924 \u092a\u0930 \u0935\u093f\u091a\u093e\u0930 \u0915\u0930\u0947\u0902<\/strong> \u0915\u0947\u0935\u0932 \u092a\u094d\u0930\u093e\u0930\u0902\u092d\u093f\u0915 \u0916\u0930\u0940\u0926 \u092e\u0942\u0932\u094d\u092f \u0915\u0947 \u092c\u091c\u093e\u092f<\/li>\n<\/ol>\n<p>\u0906\u092a \u0906\u091c \u091c\u094b \u0918\u091f\u0915 \u091a\u0941\u0928\u0924\u0947 \u0939\u0948\u0902, \u0935\u0947 \u0906\u092a\u0915\u0940 \u0938\u0941\u0935\u093f\u0927\u093e \u0915\u094b \u0926\u0936\u0915\u094b\u0902 \u0924\u0915 \u0938\u0947\u0935\u093e \u0926\u0947\u0902\u0917\u0947\u0964 \u0909\u091a\u093f\u0924 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936\u0928 \u092e\u0947\u0902 \u0938\u092e\u092f \u0928\u093f\u0935\u0947\u0936 \u0915\u0930\u0928\u0947 \u0914\u0930 \u0917\u0941\u0923\u0935\u0924\u094d\u0924\u093e\u092a\u0942\u0930\u094d\u0923 \u0909\u0924\u094d\u092a\u093e\u0926\u094b\u0902 \u092e\u0947\u0902 \u092e\u093e\u092e\u0942\u0932\u0940 \u0905\u0924\u093f\u0930\u093f\u0915\u094d\u0924 \u092c\u091c\u091f \u0932\u0917\u093e\u0928\u0947 \u0938\u0947 \u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u0938\u0902\u091a\u093e\u0932\u0928, \u0915\u0941\u0936\u0932 \u0930\u0916\u0930\u0916\u093e\u0935 \u0914\u0930 \u0935\u093f\u092b\u0932\u0924\u093e\u0913\u0902 \u0938\u0947 \u092c\u091a\u093e\u0935 \u0915\u0947 \u0930\u0942\u092a \u092e\u0947\u0902 \u0932\u093e\u092d \u092e\u093f\u0932\u0924\u093e \u0939\u0948\u0964 \u092f\u0939\u093e\u0902 \u092a\u094d\u0930\u0938\u094d\u0924\u0941\u0924 \u091a\u0947\u0915\u0932\u093f\u0938\u094d\u091f \u0914\u0930 \u092e\u093e\u0928\u0926\u0902\u0921\u094b\u0902 \u0915\u094b \u0905\u092a\u0928\u0947 \u0905\u0917\u0932\u0947 \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u092a\u094d\u0930\u094b\u091c\u0947\u0915\u094d\u091f \u092e\u0947\u0902 \u0932\u093e\u0917\u0942 \u0915\u0930\u0947\u0902, \u0914\u0930 \u0906\u092a \u0910\u0938\u0947 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0938\u093f\u0938\u094d\u091f\u092e \u092c\u0928\u093e\u090f\u0902\u0917\u0947 \u091c\u094b \u0935\u0947 \u0938\u092e\u0930\u094d\u0925\u093f\u0924 \u092a\u0930\u093f\u0937\u094d\u0915\u0943\u0924 \u0938\u0941\u0930\u0915\u094d\u0937\u093e \u0914\u0930 \u0938\u094d\u0935\u093f\u091a\u093f\u0902\u0917 \u0909\u092a\u0915\u0930\u0923\u094b\u0902 \u0915\u0947 \u092f\u094b\u0917\u094d\u092f \u0939\u094b\u0902\u0964.<\/p>\n<h2>\u0938\u0902\u092c\u0902\u0927\u093f\u0924 \u0924\u0915\u0928\u0940\u0915\u0940 \u0938\u0902\u0938\u093e\u0927\u0928<\/h2>\n<ul>\u0906\u0930\u090f\u0928<\/p>\n<li><a href=\"https:\/\/xbrele.com\/hi\/control-wiring-emc-false-trip-prevention\/\">\u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0908\u090f\u092e\u0938\u0940 \u091d\u0942\u0920\u0940 \u091f\u094d\u0930\u093f\u092a \u0930\u094b\u0915\u0925\u093e\u092e<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/control-cable-selection-mv-panels\/\">\u090f\u092e\u0935\u0940 \u092a\u0948\u0928\u0932\u094b\u0902 \u0915\u0947 \u0932\u093f\u090f \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0915\u0947\u092c\u0932 \u091a\u092f\u0928<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/\">\u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u092a\u0941\u0930\u094d\u091c\u0947 \u0914\u0930 \u0907\u0928\u094d\u0938\u0941\u0932\u0947\u0936\u0928 \u0918\u091f\u0915<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/switchgear-parts\/contact-box\/\">\u090f\u092a\u0949\u0915\u094d\u0938\u0940 \u0938\u0902\u092a\u0930\u094d\u0915 \u092c\u0949\u0915\u094d\u0938 \u0918\u091f\u0915 \u0935\u093f\u0935\u0930\u0923<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/hi\/switchgear\/\">\u092e\u0927\u094d\u092f\u092e-\u0935\u094b\u0932\u094d\u091f\u0947\u091c \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u0915\u0947 \u0921\u093f\u091c\u093e\u0907\u0928 \u0915\u0947 \u092e\u0942\u0932 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924<\/a><\/li>\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/C37.2\/\" target=\"_blank\" rel=\"noopener\">IEEE C37.2 \u0909\u092a\u0915\u0930\u0923 \u0915\u093e\u0930\u094d\u092f \u0938\u0902\u0916\u094d\u092f\u093e\u090f\u0901 \u0914\u0930 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0928\u093e\u092e\u0915\u0930\u0923<\/a><\/li>\n<\/ul>\n<p><!-- seo-final-3691 --><\/p>","protected":false},"excerpt":{"rendered":"<p>\u0935\u093f\u0936\u094d\u0935\u0938\u0928\u0940\u092f \u090f\u092e\u0935\u0940 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u0935\u093e\u092f\u0930\u093f\u0902\u0917 \u0915\u0947 \u0932\u093f\u090f \u0938\u094d\u0935\u093f\u091a\u0917\u093f\u092f\u0930 \u091f\u0930\u094d\u092e\u093f\u0928\u0932 \u092c\u094d\u0932\u0949\u0915 \u092c\u094d\u0930\u093e\u0902\u0921\u094b\u0902, \u0930\u0947\u091f\u093f\u0902\u0917\u094d\u0938, \u0938\u093e\u092e\u0917\u094d\u0930\u093f\u092f\u094b\u0902, \u092a\u094d\u0930\u092e\u093e\u0923\u092a\u0924\u094d\u0930\u094b\u0902 \u0914\u0930 \u0907\u0902\u0938\u094d\u091f\u0949\u0932\u0947\u0936\u0928 \u091c\u093e\u0902\u091a\u094b\u0902 \u0915\u0940 \u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0947\u0902\u0964.<\/p>","protected":false},"author":3,"featured_media":3686,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3691","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/3691","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/comments?post=3691"}],"version-history":[{"count":15,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/3691\/revisions"}],"predecessor-version":[{"id":4115,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/posts\/3691\/revisions\/4115"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media\/3686"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/media?parent=3691"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/categories?post=3691"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/hi\/wp-json\/wp\/v2\/tags?post=3691"}],"curies":[{"name":"\u0921\u092c\u094d\u0932\u094d\u092f\u0942\u092a\u0940","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}