{"id":1963,"date":"2025-12-04T13:53:51","date_gmt":"2025-12-04T13:53:51","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1963"},"modified":"2025-12-04T15:16:51","modified_gmt":"2025-12-04T15:16:51","slug":"vacuum-contactor-manufacturer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/it\/vacuum-contactor-manufacturer\/","title":{"rendered":"Produttore di contattori per vuoto"},"content":{"rendered":"<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-e0fd90d\" data-block-id=\"e0fd90d\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-e0fd90d-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-3f3b46e\" data-v=\"4\" data-block-id=\"3f3b46e\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-3f3b46e-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-3f3b46e-inner-blocks\">\n<style>\n    \/* --- XBRELE PRO STYLE SYSTEM (v5.1 - Contactor Edition) --- *\/\n    \n    .xbrele-pro-page {\n        font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        color: #111;\n        line-height: 1.7; \n        font-size: 18px; \n        font-weight: 400;\n        background-color: #fff;\n    }\n\n    .xbrele-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        padding: 0 20px;\n    }\n\n    .xbrele-section {\n        padding: 60px 0;\n        border-bottom: 1px solid #f0f0f0;\n    }\n    .xbrele-section.bg-light {\n        background-color: #f8fbfb;\n    }\n\n    .xbrele-pro-page h1 {\n        font-size: 42px;\n        font-weight: 800;\n        text-align: center;\n        margin-bottom: 30px;\n        color: #000;\n        letter-spacing: -0.5px;\n    }\n    \n    .xbrele-pro-page h2 {\n        font-size: 30px;\n        color: #000;\n        margin-top: 50px;\n        margin-bottom: 25px;\n        position: relative;\n        padding-left: 20px;\n        border-left: 8px solid #009688; \/* XBRELE Teal *\/\n        font-weight: 700;\n        text-transform: uppercase;\n    }\n    \n    .xbrele-pro-page h3 {\n        font-size: 22px;\n        font-weight: 700;\n        margin-top: 35px;\n        margin-bottom: 15px;\n        color: #009688;\n    }\n\n    .xbrele-pro-page p {\n        margin-bottom: 25px;\n        color: #222;\n        text-align: justify;\n    }\n\n    \/* Hero \u56fe\u7247\u6837\u5f0f *\/\n    .xbrele-hero-img {\n        width: 100%;\n        height: auto;\n        border-radius: 6px;\n        margin-bottom: 40px;\n        box-shadow: 0 4px 12px rgba(0,0,0,0.1);\n        display: block;\n    }\n\n    .xbrele-list {\n        list-style: none;\n        padding: 0;\n        margin-bottom: 30px;\n    }\n    .xbrele-list li {\n        position: relative;\n        padding-left: 30px;\n        margin-bottom: 12px;\n        color: #222;\n    }\n    .xbrele-list li::before {\n        content: \"\u25a0\";\n        position: absolute;\n        left: 0;\n        color: #009688;\n        font-size: 14px;\n        top: 6px;\n    }\n\n    .xbrele-tech-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 40px 0;\n        box-shadow: 0 5px 15px rgba(0,0,0,0.05);\n        font-size: 16px;\n    }\n    .xbrele-tech-table th, .xbrele-tech-table td {\n        padding: 18px;\n        border: 1px solid #ddd;\n    }\n    .xbrele-tech-table th {\n        background-color: #009688;\n        color: #fff;\n        font-weight: 700;\n        text-align: left;\n    }\n    .xbrele-tech-table tr:nth-child(even) {\n        background-color: #fcfcfc;\n    }\n\n    .xbrele-link {\n        color: #009688;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid rgba(0,150,136,0.2);\n        transition: all 0.2s;\n    }\n    .xbrele-link:hover {\n        background-color: rgba(0,150,136,0.1);\n        border-bottom-color: #009688;\n    }\n\n    .xbrele-ext-link {\n        color: #555;\n        text-decoration: underline;\n        font-style: italic;\n    }\n\n    .xbrele-cta-box {\n        background: linear-gradient(135deg, #009688 0%, #004d40 100%);\n        color: #fff;\n        padding: 60px;\n        border-radius: 8px;\n        text-align: center;\n        margin-top: 60px;\n    }\n    .xbrele-cta-btn {\n        display: inline-block;\n        background-color: #fff;\n        color: #009688 !important;\n        padding: 18px 45px;\n        font-weight: 800;\n        text-transform: uppercase;\n        border-radius: 4px;\n        text-decoration: none;\n        margin-top: 25px;\n        font-size: 18px;\n        box-shadow: 0 4px 6px rgba(0,0,0,0.2);\n    }\n    .xbrele-cta-btn:hover {\n        background-color: #f4f4f4;\n        transform: translateY(-2px);\n    }\n<\/style>\n\n<div class=\"xbrele-pro-page\">\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h1>Produttore di contattori per vuoto e soluzioni OEM<\/h1>\n            \n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-contactor-factory-production-line.webp\" \n                 alt=\"XBRELE Produttore di contattori a vuoto per alta tensione e contattori per miniere\" \n                 class=\"xbrele-hero-img\" \/>\n\n            <p>\n                La produzione di contattori sottovuoto \u00e8 un settore specializzato dell'ingegneria elettrica incentrato sulla produzione di dispositivi di commutazione ad alta resistenza per applicazioni che richiedono un funzionamento frequente. A differenza degli interruttori automatici, progettati per proteggere da guasti rari, i contattori sottovuoto sono i cavalli di battaglia del settore, progettati per commutare motori, trasformatori e banchi di condensatori centinaia di migliaia di volte. In qualit\u00e0 di leader <strong>Produttore di contattori per vuoto<\/strong>, XBRELE produce una gamma completa di unit\u00e0 a bassa tensione (1,14 kV) e alta tensione (7,2 kV - 40,5 kV). Il nostro stabilimento integra una tecnologia avanzata di azionamento elettromagnetico con interruttori a vuoto di alta qualit\u00e0, fornendo soluzioni di controllo affidabili per i settori minerario, metallurgico e dell'industria pesante in tutto il mondo.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Processo di produzione dei contattori a vuoto<\/h2>\n            <p>\n                Il processo di produzione dei contattori sottovuoto privilegia la resistenza meccanica e la stabilit\u00e0 elettrica. Mentre un interruttore pu\u00f2 funzionare 10.000 volte, un contattore deve funzionare in modo affidabile fino a <strong>1.000.000 di operazioni meccaniche<\/strong>. Ci\u00f2 richiede un approccio produttivo diverso.\n            <\/p>\n            <p>\n                <strong>Assemblaggio del sistema elettromagnetico:<\/strong> Il cuore di un contattore \u00e8 il suo azionamento a solenoide. XBRELE avvolge le proprie bobine in rame di alta qualit\u00e0 e assembla il giogo magnetico con parti stampate di precisione. Utilizziamo un circuito \u201cDouble-Coil\u201d o \u201cPWM Control\u201d appositamente progettato per ridurre al minimo il consumo energetico di mantenimento e ridurre la generazione di calore durante il funzionamento continuo.\n            <\/p>\n            <p>\n                <strong>Allineamento dell'interruttore a vuoto:<\/strong> Per il <a href=\"https:\/\/xbrele.com\/it\/vacuum-contactor\/jcz-vacuum-contactor\/\" class=\"xbrele-link\">Serie JCZ ad alta tensione<\/a>, l'allineamento dell'interruttore a vuoto \u00e8 fondamentale. Utilizziamo dispositivi automatizzati per impostare la distanza tra i contatti e la corsa eccessiva con una precisione di 0,1 mm. Questa precisione garantisce che le tre fasi si chiudano simultaneamente, impedendo il \u201cmonofase\u201d che pu\u00f2 danneggiare i motori sensibili.\n            <\/p>\n            <p>\n                <strong>Modanatura del telaio isolante:<\/strong> Per le nostre serie destinate all'industria mineraria e con isolamento solido, stampiamo i telai utilizzando DMC (Dough Molding Compound) o resina epossidica ad alta resistenza. Questa struttura robusta previene i guasti causati dalle vibrazioni, un requisito comune per le attrezzature minerarie sotterranee.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Materie prime utilizzate nella produzione di contattori per vuoto<\/h2>\n            <p>\n                Per ottenere un'elevata frequenza di commutazione (fino a 1.200 volte\/ora), i materiali utilizzati nei contattori sottovuoto devono resistere a sollecitazioni estreme. XBRELE seleziona materiali che garantiscono una lunga durata.\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>Materiale di contatto (WCu vs CuCr):<\/strong> All'interno della bottiglia sottovuoto, selezioniamo leghe specifiche in base al carico. Per la commutazione dei condensatori, utilizziamo materiali di contatto a bassa tensione per evitare ricariche. Per l'avvio di motori pesanti (servizio AC-4), utilizziamo leghe resistenti di tungsteno-rame (WCu) o CuCr che resistono all'erosione elettrica.<\/li>\n                <li><strong>Filo di rame smaltato:<\/strong> Le nostre bobine di controllo utilizzano filo di rame smaltato di classe H (180 \u00b0C), garantendo il funzionamento del motore elettromagnetico anche in caso di aumento significativo della temperatura ambiente nella sala quadri.<\/li>\n                <li><strong>Materiali isolanti:<\/strong> Per il <a href=\"https:\/\/xbrele.com\/it\/vacuum-contactor\/low-voltage-vacuum-contactor-solid-series\/\" class=\"xbrele-link\">Serie con palo solido incorporato (LZNJ)<\/a>, utilizziamo resina epossidica cicloalifatica idrofobica, che offre una resistenza superiore alle tracce elettriche in ambienti esterni o umidi.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Attrezzature essenziali per la produzione<\/h2>\n            <p>\n                La produzione di contattori ad alte prestazioni si basa su macchinari specializzati per l'assemblaggio e il collaudo. XBRELE ha investito in una linea di produzione completamente attrezzata per garantire la coerenza.\n            <\/p>\n            <p>\n                <strong>Macchine avvolgitrici automatiche:<\/strong> Per garantire che le tensioni di pull-in e drop-out siano uniformi in ogni lotto, le nostre bobine solenoidi sono avvolte su macchine avvolgitrici automatiche ad alta velocit\u00e0 con controllo della tensione.\n            <\/p>\n            <p>\n                <strong>Banchi prova di rodaggio:<\/strong> A differenza di alcuni fornitori che spediscono immediatamente dopo l'assemblaggio, XBRELE utilizza banchi di \u201crodaggio meccanico\u201d. Ogni contattore viene sottoposto a oltre 300 operazioni a vuoto per assestare le molle meccaniche e i fermi prima della calibrazione finale.\n            <\/p>\n            <p>\n                <strong>Saldatura sotto vuoto (controllo esternalizzato):<\/strong> Pur acquistando bottiglie sottovuoto da specialisti di prim'ordine, manteniamo rigorosi standard di controllo qualit\u00e0 in entrata (IQC) per verificare la qualit\u00e0 della brasatura e l'integrit\u00e0 del sottovuoto di ogni lotto prima che entri nella nostra linea di assemblaggio.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Procedure di collaudo per contattori a vuoto<\/h2>\n            <p>\n                Le procedure di collaudo dei contattori a vuoto sono incentrate sulla resistenza e sull'affidabilit\u00e0 in condizioni di cicli frequenti. XBRELE applica rigorosi controlli di qualit\u00e0 conformi alle norme IEC 60470 e GB\/T 14808.\n            <\/p>\n            \n            <table class=\"xbrele-tech-table\">\n                <tr>\n                    <th>Nome del test<\/th>\n                    <th>Standard \/ Limite<\/th>\n                    <th>Scopo<\/th>\n                <\/tr>\n                <tr>\n                    <td><strong>Tensione di pick-up e drop-out<\/strong><\/td>\n                    <td>85% \u2013 110% Noi<\/td>\n                    <td>Garantisce la chiusura affidabile del contattore anche in caso di cali di tensione.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Resistenza alla frequenza di rete<\/strong><\/td>\n                    <td>32 kV \/ 42 kV (per 7,2\/12 kV)<\/td>\n                    <td>Verifica la rigidit\u00e0 dielettrica tra i contatti aperti e verso terra.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Resistenza del circuito principale<\/strong><\/td>\n                    <td>&lt; 60-80 \u03bc\u03a9<\/td>\n                    <td>Controlla che la pressione di contatto sia corretta per evitare il surriscaldamento.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Test di sincronizzazione<\/strong><\/td>\n                    <td>&lt; 2 ms di differenza<\/td>\n                    <td>Assicura che tutte e tre le fasi entrino in contatto simultaneamente.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Controllo del grado di vuoto<\/strong><\/td>\n                    <td>Prova della scintilla \/ Magnetrone<\/td>\n                    <td>Conferma che la bottiglia sottovuoto non ha perso durante il montaggio.<\/td>\n                <\/tr>\n            <\/table>\n            \n            <p>\n                Per i nostri modelli con \u201cbloccaggio meccanico\u201d (utilizzati nei casi in cui il consumo energetico deve essere pari a zero durante il mantenimento), eseguiamo ulteriori test di affidabilit\u00e0 del bloccaggio per garantire che il dispositivo rimanga chiuso anche in presenza di forti vibrazioni.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Perch\u00e9 dovresti lavorare con un produttore di contattori personalizzati<\/h2>\n            <p>\n                I contattori a vuoto non sono prodotti \u201cplug and play\u201d; spesso devono essere adattati a specifici avviatori motore legacy o macchinari specializzati. Un produttore personalizzato come XBRELE consente di adattare il dispositivo alla propria applicazione.\n            <\/p>\n            <p>\n                Offriamo personalizzazione in <strong>Tipo di tenuta<\/strong>. Siamo in grado di produrre <strong>Holding elettrica<\/strong> tipi (standard) o <strong>Bloccaggio meccanico<\/strong> tipi (che rimangono chiusi senza alimentazione, ideali per reti instabili).\n            <\/p>\n            <p>\n                Per l'industria mineraria, personalizziamo il <a href=\"https:\/\/xbrele.com\/it\/vacuum-contactor\/low-voltage-vacuum-contactor-solid-series\/\" class=\"xbrele-link\">Serie CKJ (1,14 kV)<\/a> con telai rinforzati e tensioni di controllo speciali (ad es. CA 36 V, 127 V) comunemente utilizzate nei sistemi elettrici sotterranei. Possiamo anche regolare la disposizione dei terminali per adattarla alle configurazioni delle sbarre collettrici esistenti, consentendovi di risparmiare notevoli costi di retrofit.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>I produttori di contattori a vuoto hanno una grande esperienza<\/h2>\n            <p>\n                La produzione di contattori richiede una conoscenza approfondita delle \u201ccategorie di utilizzo\u201d (AC-3, AC-4). Gli ingegneri XBRELE comprendono che la commutazione di un motore (carico induttivo) \u00e8 fisicamente diversa dalla commutazione di un banco di condensatori (carico capacitivo).\n            <\/p>\n            <p>\n                La nostra esperienza ci consente di consigliare il prodotto giusto. Ad esempio, per le applicazioni di commutazione dei condensatori, consigliamo il nostro <a href=\"https:\/\/xbrele.com\/it\/vacuum-contactor\/ckg-vacuum-contactor\/\" class=\"xbrele-link\">Serie CKG<\/a> dotati di resistori pre-inserimento specializzati o flaconi sottovuoto di alta qualit\u00e0 progettati per resistere alle elevate correnti di spunto e alla tensione di recupero transitoria (TRV) associate ai banchi di condensatori.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Soluzioni di produzione convenienti<\/h2>\n            <p>\n                Acquistando direttamente da XBRELE in Cina, gli OEM e i distributori globali ottengono un vantaggio competitivo. Produciamo internamente gli azionamenti a solenoide e i telai isolanti, evitando il ricarico degli assemblatori che acquistano i componenti esternamente.\n            <\/p>\n            <p>\n                Il nostro <a href=\"https:\/\/xbrele.com\/it\/vacuum-contactor\/low-voltage-vacuum-contactor-solid-series\/\" class=\"xbrele-link\">Contattori a vuoto a bassa tensione (1140 V)<\/a> sono ampiamente utilizzati come sostituti economici dei costosi contattori ad aria compressa nelle applicazioni pesanti. Offrono una durata elettrica 10 volte superiore a un prezzo comparabile, riducendo drasticamente il costo totale di propriet\u00e0 (TCO) per gli utenti finali in cementifici, acciaierie e miniere.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Capacit\u00e0 produttive adattabili<\/h2>\n            <p>\n                Le linee di produzione di XBRELE sono progettate per garantire la massima versatilit\u00e0. Produciamo sia prodotti standard <strong>Contattori a 3 poli<\/strong> (JCZ5) e specializzato <strong>Contattori unipolari<\/strong> (JCZ1) utilizzato nelle locomotive elettriche e nei sistemi di riscaldamento a induzione.\n            <\/p>\n            <p>\n                La nostra adattabilit\u00e0 si estende anche agli stili di installazione. Offriamo unit\u00e0 fisse per pannelli standard e unit\u00e0 di tipo carrellato compatibili con i quadri elettrici KYN28, che consentono di inserire e rimuovere il contattore proprio come un interruttore automatico. Questa flessibilit\u00e0 rende XBRELE il partner preferito dai costruttori di quadri elettrici che devono soddisfare esigenze di progetto diverse.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Pratiche di produzione sostenibili<\/h2>\n            <p>\n                I moderni contattori a vuoto sono intrinsecamente ecologici. A differenza degli interruttori a olio o SF6, la tecnologia a vuoto non emette gas serra e non comporta rischi di incendio. XBRELE fa un ulteriore passo avanti ottimizzando i nostri circuiti di controllo.\n            <\/p>\n            <p>\n                I nostri moduli di controllo elettronico utilizzano la modulazione di larghezza di impulso (PWM) o bobine a risparmio energetico che riducono la potenza di tenuta fino al 90% rispetto alle bobine CA tradizionali. Ci\u00f2 non solo riduce l'impronta di carbonio del funzionamento, ma abbassa anche il carico termico all'interno dell'armadio elettrico, prolungando la durata degli altri componenti.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>Vantaggi della produzione cinese di contattori a vuoto<\/h2>\n            <p>\n                La Cina \u00e8 leader mondiale nella produzione di tecnologia di commutazione sottovuoto. XBRELE sfrutta la catena di fornitura consolidata di Wenzhou per offrire:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>Prototipazione rapida:<\/strong> Siamo in grado di sviluppare piastre di montaggio personalizzate o adattatori per sbarre collettrici in meno di 10 giorni.<\/li>\n                <li><strong>Gamma diversificata:<\/strong> Dalle unit\u00e0 LV da 80 A alle unit\u00e0 HV da 630 A, copriamo l'intera gamma.<\/li>\n                <li><strong>Ingegneria del valore:<\/strong> Fornitura di prodotti conformi alle norme IEC ad alte prestazioni a un prezzo economicamente vantaggioso per i mercati emergenti.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>Trovare il giusto produttore di contattori sottovuoto<\/h2>\n            <p>\n                Quando scegli un partner, non limitarti a guardare il catalogo. Considera anche:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>Valori nominali del ciclo di lavoro:<\/strong> Il produttore classifica i propri prodotti per impieghi AC-4 (jogging\/plugging)?<\/li>\n                <li><strong>Affidabilit\u00e0 delle bobine:<\/strong> Offrono bobine ad ampio voltaggio (ad esempio, universali da 110-220 V)?<\/li>\n                <li><strong>Certificazione:<\/strong> I prodotti sono testati da laboratori certificati?<\/li>\n                <li><strong>Ricambi:<\/strong> Possono fornire bottiglie sottovuoto e serpentine di ricambio?<\/li>\n            <\/ul>\n            <p>\n                XBRELE fornisce dati tecnici trasparenti e un'assistenza post-vendita completa, garantendo il funzionamento ininterrotto dei vostri centri di controllo motori.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-container\">\n        <div class=\"xbrele-cta-box\">\n            <h2>Sei pronto ad acquistare da una fabbrica verificata?<\/h2>\n            <p>Smetti di pagare i margini dei trader. Contatta direttamente il team di ingegneri di XBRELE per le tue esigenze relative ai contattori sottovuoto.<\/p>\n            <a href=\"https:\/\/xbrele.com\/it\/contact\/\" class=\"xbrele-cta-btn\">Richiedi un preventivo di fabbrica<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum Contactor Manufacturer &#038; OEM Solutions Vacuum Contactor manufacturing is a specialized field within electrical engineering focused on producing high-endurance switching devices for frequent operation applications. Unlike circuit breakers, which are designed for rare fault protection, Vacuum Contactors are the workhorses of the industry, engineered to switch motors, transformers, and capacitor banks hundreds of thousands [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1963","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"top","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/pages\/1963","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/comments?post=1963"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/pages\/1963\/revisions"}],"predecessor-version":[{"id":1997,"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/pages\/1963\/revisions\/1997"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/it\/wp-json\/wp\/v2\/media?parent=1963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}