{"id":1135,"date":"2025-11-19T09:03:32","date_gmt":"2025-11-19T09:03:32","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1135"},"modified":"2025-11-20T08:33:33","modified_gmt":"2025-11-20T08:33:33","slug":"zw20-vacuum-circuit-breaker","status":"publish","type":"page","link":"https:\/\/xbrele.com\/pt\/vacuum-circuit-breaker\/zw20-vacuum-circuit-breaker\/","title":{"rendered":"Disjuntor a v\u00e1cuo ZW20"},"content":{"rendered":"\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-ac80509\" data-block-id=\"ac80509\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-ac80509-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-f5c5e7d\" data-v=\"4\" data-block-id=\"f5c5e7d\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-f5c5e7d-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-f5c5e7d-inner-blocks\">\n<section id=\"sec1-zw20-hero\">\n  <style>\n    #sec1-zw20-hero{\n      padding:200px 0 128px;\n      background:#0B1120;\n      color:#E5E7EB;\n    }\n\n    #sec1-zw20-hero .zw20-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      display:grid;\n      grid-template-columns:minmax(0,1.2fr) minmax(0,1fr);\n      gap:40px;\n      align-items:center;\n    }\n\n    @media(max-width:900px){\n      #sec1-zw20-hero{\n        padding:140px 0 96px;\n      }\n      #sec1-zw20-hero .zw20-shell{\n        grid-template-columns:1fr;\n      }\n    }\n\n    @media(max-width:600px){\n      #sec1-zw20-hero{\n        padding:110px 0 72px;\n      }\n    }\n\n    #sec1-zw20-hero .zw20-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:10px;\n    }\n\n    #sec1-zw20-hero h1{\n      font-size:32px;\n      line-height:1.2;\n      margin:0 0 16px;\n      color:#F9FAFB;\n    }\n\n    #sec1-zw20-hero .zw20-sub{\n      font-size:15px;\n      line-height:1.8;\n      color:#D1D5DB;\n      margin-bottom:24px;\n    }\n\n    #sec1-zw20-hero .zw20-meta{\n      font-size:13px;\n      color:#9CA3AF;\n      margin-bottom:24px;\n    }\n\n    #sec1-zw20-hero .zw20-cta-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:14px;\n      align-items:center;\n    }\n\n    #sec1-zw20-hero .btn-primary{\n      display:inline-flex;\n      align-items:center;\n      justify-content:center;\n      padding:0 26px;\n      height:44px;\n      border-radius:999px;\n      border:none;\n      background:#00B8B8;\n      color:#0B1120;\n      font-size:14px;\n      font-weight:600;\n      text-decoration:none;\n      cursor:pointer;\n      transition:background .2s ease, transform .2s ease, box-shadow .2s ease;\n      box-shadow:0 18px 40px rgba(0,184,184,.35);\n    }\n\n    #sec1-zw20-hero .btn-primary:hover{\n      background:#06A4A4;\n      transform:translateY(-1px);\n      box-shadow:0 20px 48px rgba(0,184,184,.40);\n    }\n\n    #sec1-zw20-hero .btn-ghost{\n      display:inline-flex;\n      align-items:center;\n      justify-content:center;\n      padding:0 22px;\n      height:44px;\n      border-radius:999px;\n      border:1px solid rgba(148,163,184,.6);\n      background:transparent;\n      color:#E5E7EB;\n      font-size:14px;\n      font-weight:500;\n      text-decoration:none;\n      cursor:pointer;\n      transition:background .2s ease, border-color .2s ease, color .2s ease;\n    }\n\n    #sec1-zw20-hero .btn-ghost:hover{\n      background:rgba(15,23,42,.85);\n      border-color:#00B8B8;\n      color:#F9FAFB;\n    }\n\n    \/* \u53f3\u4fa7\u5361\u7247 *\/\n    #sec1-zw20-hero .zw20-hero-media{\n      position:relative;\n      min-height:220px;\n      border-radius:20px;\n      background:radial-gradient(circle at 70% 20%,#00B8B8 0,rgba(15,23,42,1) 55%, #020617 100%);\n      overflow:hidden;\n      padding:22px 22px 20px;\n    }\n\n    \/* \u5de6\u4e0a\u89d2\u5c0f\u6807\u9898 + \u8bf4\u660e *\/\n    #sec1-zw20-hero .zw20-hero-label{\n      font-size:11px;\n      text-transform:uppercase;\n      letter-spacing:.14em;\n      color:#E5E7EB;\n      opacity:.9;\n      margin-bottom:4px;\n    }\n\n    #sec1-zw20-hero .zw20-hero-text{\n      font-size:13px;\n      color:#C4CFDE;\n      max-width:70%;\n      line-height:1.6;\n    }\n\n    \/* \u53f3\u4e0a\u89d2\u7cfb\u5217\u6807\u7b7e *\/\n    #sec1-zw20-hero .zw20-hero-tag{\n      position:absolute;\n      top:18px;\n      right:18px;\n      padding:4px 12px;\n      border-radius:999px;\n      background:rgba(15,23,42,.8);\n      border:1px solid rgba(148,163,184,.6);\n      font-size:11px;\n      color:#E5E7EB;\n      white-space:nowrap;\n    }\n\n    \/* \u5de6\u4e0b\u89d2\u8bf4\u660e\u6587\u5b57 *\/\n    #sec1-zw20-hero .zw20-hero-note{\n      position:absolute;\n      left:22px;\n      bottom:18px;\n      font-size:12px;\n      color:#9CA3AF;\n      max-width:76%;\n      line-height:1.7;\n    }\n  <\/style>\n\n  <div class=\"zw20-shell\">\n    <div class=\"zw20-copy\">\n      <div class=\"zw20-kicker\">MV &amp; HV VACUUM CIRCUIT BREAKERS<\/div>\n      <h1>ZW20 Vacuum Circuit Breaker for 12kV Overhead Distribution Networks<\/h1>\n      <p class=\"zw20-sub\">\n        XBRELE designs and manufactures outdoor ZW20 vacuum circuit breakers for 12&nbsp;kV\n        medium-voltage power systems, providing reliable protection and automation for\n        overhead distribution networks. ZW20 series can be configured as automatic\n        reclosers for feeder and transformer protection.\n      <\/p>\n      <p class=\"zw20-meta\">\n        XBRELE supplies the ZW20 vacuum circuit breaker series to utilities and industrial\n        users in India, the Middle East, Russia and other emerging markets, offering\n        flexible configurations for new projects and replacement of existing switchgear.\n      <\/p>\n      <div class=\"zw20-cta-row\">\n        <a href=\"\/contact\/\" class=\"btn-primary\">Request a Quote<\/a>\n        <a href=\"\/vacuum-circuit-breakers\/#sec7-vcb-faq\" class=\"btn-ghost\">View selection FAQ<\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"zw20-hero-media\">\n      <div class=\"zw20-hero-label\">ZW20 series snapshot<\/div>\n      <div class=\"zw20-hero-text\">\n        ZW20 is an outdoor 12&nbsp;kV vacuum circuit breaker that can operate as an\n        automatic recloser on medium-voltage overhead lines, protecting feeders and\n        distribution transformers.\n      <\/div>\n\n      <div class=\"zw20-hero-tag\">ZW20 \u00b7 12kV \u00b7 Outdoor VCB<\/div>\n\n      <div class=\"zw20-hero-note\">\n        Typical use cases: 12&nbsp;kV overhead line reclosers, MV feeders and\n        transformer protection points in utility and industrial distribution systems.\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-abf5471\" data-block-id=\"abf5471\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-abf5471-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-9013462\" data-v=\"4\" data-block-id=\"9013462\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-9013462-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-9013462-inner-blocks\">\n<section id=\"sec2-zw20-overview\" style=\"background:#ffffff;padding:90px 0 105px;color:#0f172a;\">\n  <style>\n    #sec2-zw20-overview{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec2-zw20-overview .zw20-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec2-zw20-overview .overview-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.4fr) minmax(0,1fr);\n      gap:52px;\n      align-items:center;\n    }\n    #sec2-zw20-overview .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38bdf8;\n      margin-bottom:10px;\n    }\n    #sec2-zw20-overview h2{\n      font-size:28px;\n      margin:0 0 14px;\n      color:#0f172a;\n    }\n    #sec2-zw20-overview p{\n      font-size:16px;\n      line-height:1.85;\n      margin:0 0 16px;\n      color:#4b5563;\n    }\n    #sec2-zw20-overview .apps-box{\n      background:#f9fafb;\n      padding:22px 24px 20px;\n      border-radius:18px;\n      border:1px solid #e5e7eb;\n    }\n    #sec2-zw20-overview .apps-box h3{\n      font-size:15px;\n      margin:0 0 12px;\n      text-transform:uppercase;\n      letter-spacing:.14em;\n      color:#6b7280;\n    }\n    #sec2-zw20-overview ul{\n      list-style:none;\n      padding:0;\n      margin:0;\n      display:grid;\n      gap:10px;\n      font-size:14px;\n      color:#374151;\n    }\n    #sec2-zw20-overview ul li{\n      position:relative;\n      padding-left:16px;\n      line-height:1.7;\n    }\n    #sec2-zw20-overview ul li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38bdf8;\n    }\n\n    @media(max-width:1000px){\n      #sec2-zw20-overview .overview-grid{\n        grid-template-columns:1fr;\n      }\n    }\n  <\/style>\n\n  <div class=\"zw20-shell\">\n    <div class=\"overview-grid\">\n\n      <!-- LEFT TEXT -->\n      <div>\n        <div class=\"kicker\">Series overview<\/div>\n        <h2>ZW20 vacuum circuit breaker for 12kV overhead networks<\/h2>\n\n        <p>\n          The ZW20 vacuum circuit breaker is an outdoor 12&nbsp;kV switching device for medium-voltage\n          overhead distribution networks. Each ZW20 unit integrates the vacuum interrupter, solid-insulated\n          embedded pole, operating mechanism and current transformers into a compact, fully enclosed body\n          suitable for long-term field operation.\n        <\/p>\n\n        <p>\n          With the embedded pole design, the ZW20 vacuum circuit breaker achieves high insulation level and\n          protects the interrupter from moisture, dust and pollution. Together with a stable spring operating\n          mechanism, it delivers reliable opening and closing performance under frequent switching conditions\n          on distribution feeders.\n        <\/p>\n\n        <p>\n          In standard configuration the ZW20 works as a pole-mounted vacuum circuit breaker. When it is\n          equipped with a suitable controller and sensors, the same ZW20 vacuum circuit breaker can be\n          configured as an automatic recloser for feeder protection and distribution automation on 12&nbsp;kV\n          networks.\n        <\/p>\n\n        <p style=\"margin-top:14px;font-size:14px;color:#4b5563;\">\n          For a broader view of XBRELE\u2019s outdoor vacuum circuit breakers, please visit the\n          <a href=\"https:\/\/xbrele.com\/vacuum-circuit-breaker\/\" style=\"color:#2563EB;text-decoration:none;\">\n            vacuum circuit breaker pillar page\n          <\/a>.\n        <\/p>\n      <\/div>\n\n      <!-- RIGHT BOX -->\n      <aside class=\"apps-box\">\n        <h3>Typical applications<\/h3>\n        <ul>\n          <li>12&nbsp;kV overhead feeder sectionalizing and switching points<\/li>\n          <li>Pole-mounted transformer protection and isolation<\/li>\n          <li>Distribution automation points using ZW20 as recloser<\/li>\n          <li>Urban &amp; rural medium-voltage line protection and backup<\/li>\n          <li>Replacement of ageing oil \/ SF<sub>6<\/sub> switches on existing poles<\/li>\n        <\/ul>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-c9a6d7d\" data-block-id=\"c9a6d7d\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-c9a6d7d-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-e5b348e\" data-v=\"4\" data-block-id=\"e5b348e\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-e5b348e-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-e5b348e-inner-blocks\">\n<section id=\"sec3-zw20-tech\" style=\"padding:90px 0;background:#F9FAFB;\">\n  <style>\n    #sec3-zw20-tech{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec3-zw20-tech .tech-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec3-zw20-tech .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec3-zw20-tech .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec3-zw20-tech h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-zw20-tech .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    \/* TAB Row *\/\n    #sec3-zw20-tech .tab-row{\n      display:flex;\n      justify-content:center;\n      gap:16px;\n      margin:34px 0 32px;\n    }\n    #sec3-zw20-tech .tab-btn{\n      padding:10px 26px;\n      font-size:15px;\n      font-weight:600;\n      background:#E5E7EB;\n      border-radius:6px;\n      cursor:pointer;\n      border:1px solid #D1D5DB;\n      transition:all .25s ease;\n      color:#0F172A;\n      white-space:nowrap;\n    }\n    #sec3-zw20-tech .tab-btn:hover{\n      background:#DDE3E9;\n    }\n    #sec3-zw20-tech .tab-btn.active{\n      background:#0F172A;\n      color:#F9FAFB;\n      border-color:#0F172A;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n    }\n\n    \/* Panels *\/\n    #sec3-zw20-tech .tab-content{\n      display:none;\n      animation:fadeIn .25s ease;\n    }\n    #sec3-zw20-tech .tab-content.active{\n      display:block;\n    }\n    @keyframes fadeIn{\n      from{opacity:0;transform:translateY(6px);}\n      to{opacity:1;transform:translateY(0);}\n    }\n\n    \/* Panel layout *\/\n    #sec3-zw20-tech .panel-card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:24px 22px 26px;\n      box-shadow:0 14px 32px rgba(15,23,42,.05);\n    }\n    #sec3-zw20-tech .panel-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.15fr) minmax(0,1.1fr);\n      gap:22px;\n      margin-bottom:20px;\n      align-items:flex-start;\n    }\n    #sec3-zw20-tech figure.main-fig{\n      margin:0;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:10px;\n    }\n    #sec3-zw20-tech figure.main-fig img{\n      display:block;\n      width:100%;\n      max-height:300px;\n      object-fit:contain;\n    }\n    #sec3-zw20-tech figure.main-fig figcaption{\n      margin-top:8px;\n      font-size:12px;\n      color:#6B7280;\n      line-height:1.6;\n    }\n    #sec3-zw20-tech .panel-right h3{\n      font-size:16px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-zw20-tech .panel-right p{\n      font-size:14px;\n      line-height:1.8;\n      margin:0 0 10px;\n      color:#4B5563;\n    }\n    #sec3-zw20-tech .badge-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:8px 0 14px;\n    }\n    #sec3-zw20-tech .badge{\n      padding:4px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid #D1D5DB;\n      background:#F9FAFB;\n      color:#4B5563;\n    }\n\n    \/* tables & dimension block *\/\n    #sec3-zw20-tech .block-title{\n      font-size:14px;\n      font-weight:600;\n      margin:4px 0 6px;\n      color:#111827;\n    }\n    #sec3-zw20-tech .block-note{\n      font-size:12px;\n      color:#6B7280;\n      margin:0 0 10px;\n    }\n    #sec3-zw20-tech .table-wrap{\n      width:100%;\n      overflow-x:auto;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      margin-bottom:18px;\n    }\n    #sec3-zw20-tech table{\n      width:100%;\n      border-collapse:collapse;\n      font-size:13px;\n      min-width:520px;\n    }\n    #sec3-zw20-tech thead{\n      background:#E5F0FF;\n    }\n    #sec3-zw20-tech th,\n    #sec3-zw20-tech td{\n      padding:8px 10px;\n      border-bottom:1px solid #E5E7EB;\n      text-align:left;\n      color:#111827;\n    }\n    #sec3-zw20-tech th{\n      font-size:12px;\n      text-transform:uppercase;\n      letter-spacing:.08em;\n      color:#374151;\n      font-weight:600;\n    }\n    #sec3-zw20-tech tbody tr:nth-child(odd){\n      background:#FFFFFF;\n    }\n    #sec3-zw20-tech tbody tr:nth-child(even){\n      background:#F9FAFB;\n    }\n\n    #sec3-zw20-tech .dim-block{\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:20px;\n      margin-top:8px;\n      align-items:stretch;\n    }\n    #sec3-zw20-tech .dim-fig{\n      margin:0;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:12px;\n    }\n    #sec3-zw20-tech .dim-fig img{\n      display:block;\n      width:100%;\n      max-height:460px;\n      object-fit:contain;\n    }\n    #sec3-zw20-tech .dim-fig figcaption{\n      margin-top:6px;\n      font-size:12px;\n      color:#6B7280;\n    }\n\n    #sec3-zw20-tech .dim-right{\n      display:flex;\n      flex-direction:column;\n      justify-content:space-between;\n    }\n\n    \/* CTA *\/\n    #sec3-zw20-tech .cta-right-col{\n      display:flex;\n      justify-content:center;\n      margin-top:26px;\n    }\n    #sec3-zw20-tech .cta-btn{\n      display:inline-block;\n      padding:12px 30px;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:15px;\n      font-weight:600;\n      border-radius:8px;\n      text-decoration:none;\n      letter-spacing:.03em;\n      transition:all .25s ease;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n      white-space:nowrap;\n    }\n    #sec3-zw20-tech .cta-btn:hover{\n      background:#1E293B;\n      box-shadow:0 14px 32px rgba(15,23,42,.25);\n      transform:translateY(-1px);\n    }\n\n    @media(max-width:1000px){\n      #sec3-zw20-tech .panel-grid,\n      #sec3-zw20-tech .dim-block{\n        grid-template-columns:1fr;\n      }\n      #sec3-zw20-tech .cta-right-col{\n        justify-content:flex-start;\n      }\n    }\n    @media(max-width:690px){\n      #sec3-zw20-tech .tech-shell{padding:0 18px;}\n      #sec3-zw20-tech h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"tech-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Technical data &#038; installation dimensions<\/div>\n      <h2>ZW20-12F \u2014 specifications and outline drawings<\/h2>\n      <p>\n        Select the voltage level below to view the corresponding product photo, key electrical ratings,\n        and outline &amp; mounting dimensions for engineering design and selection.\n      <\/p>\n    <\/div>\n\n    <!-- TAB BUTTONS -->\n    <div class=\"tab-row\">\n      <div class=\"tab-btn active\" data-tab=\"zw20-12\">ZW20-12F \u00b7 12kV<\/div>\n    <\/div>\n\n    <!-- PANEL 1: ZW20-12 -->\n    <div id=\"zw20-12\" class=\"tab-content active\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <figure class=\"main-fig\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ZW20-12f-Vacuum-circuit-breaker.webp\"\n                 alt=\"ZW20-12F outdoor vacuum circuit breaker 12kV \u2013 XBRELE\">\n            <figcaption>ZW20-12F outdoor vacuum circuit breaker (12kV), pole-mounted construction with embedded pole.<\/figcaption>\n          <\/figure>\n\n          <div class=\"panel-right\">\n            <h3>ZW20-12F technical overview<\/h3>\n            <p>\n              ZW20-12F is an outdoor vacuum recloser for 12kV overhead distribution networks, designed to provide\n              reliable protection and automation. The unit features solid insulation and an embedded pole for enhanced\n              durability and protection.\n            <\/p>\n            <p>\n              This recloser integrates a vacuum interrupter and spring operating mechanism, ensuring long-term performance\n              under frequent operations in challenging outdoor environments.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">12kV<\/span>\n              <span class=\"badge\">Outdoor<\/span>\n              <span class=\"badge\">Pole-mounted<\/span>\n              <span class=\"badge\">Embedded pole<\/span>\n            <\/div>\n            <p>\n              The table below lists the main electrical ratings for ZW20-12F.\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <!-- 12kV Specs -->\n        <p class=\"block-title\">Key electrical ratings \u2014 ZW20-12F<\/p>\n        <p class=\"block-note\">Values according to the ZW20-12F technical parameter sheet.<\/p>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th style=\"width:56px;\">No.<\/th>\n                <th>Item<\/th>\n                <th style=\"width:80px;\">Unit<\/th>\n                <th>ZW20-12F<\/th>\n              <\/tr>\n            <\/thead>\n           <tbody>\n    <tr><td>1<\/td><td>Rated voltage<\/td><td>kV<\/td><td>12<\/td><\/tr>\n    <tr><td>2<\/td><td>Rated current<\/td><td>A<\/td><td>630 \/ 1250<\/td><\/tr>\n    <tr><td>3<\/td><td>Rated frequency<\/td><td>Hz<\/td><td>50<\/td><\/tr>\n    <tr><td>4<\/td><td>Rated short-circuit breaking current<\/td><td>kA<\/td><td>20 \/ 25<\/td><\/tr>\n    <tr><td>5<\/td><td>Rated short-circuit closing current (peak)<\/td><td>kA<\/td><td>50 \/ 63<\/td><\/tr>\n    <tr><td>6<\/td><td>Mechanical life<\/td><td>operations<\/td><td>10,000<\/td><\/tr>\n    <tr><td>7<\/td><td>Rated operating voltage<\/td><td>V<\/td><td>AC\/DC220<\/td><\/tr>\n    <tr><td>8<\/td><td>Power-frequency withstand voltage (1 min, phase-to-phase)<\/td><td>kV<\/td><td>34<\/td><\/tr>\n    <tr><td>9<\/td><td>Lightning impulse withstand voltage (phase-to-phase)<\/td><td>kV<\/td><td>75 \/ 85<\/td><\/tr>\n    <tr><td>10<\/td><td>Weight<\/td><td>kg<\/td><td>\u2248 140<\/td><\/tr>\n    <tr><td>11<\/td><td>Rated current cut-off times<\/td><td>times<\/td><td>10,000<\/td><\/tr>\n    <tr><td>12<\/td><td>Rated short-circuit breaking times<\/td><td>times<\/td><td>30<\/td><\/tr>\n    <tr><td>13<\/td><td>Power frequency withstand voltage 1 min<\/td><td>kV<\/td><td>34<\/td><\/tr>\n    <tr><td>14<\/td><td>Lightning impulse withstand voltage<\/td><td>kV<\/td><td>75\/85<\/td><\/tr>\n    <tr><td>15<\/td><td>Contact spacing<\/td><td>mm<\/td><td>9<\/td><\/tr>\n    <tr><td>16<\/td><td>Contact stroke of contact<\/td><td>mm<\/td><td>3<\/td><\/tr>\n    <tr><td>17<\/td><td>Average opening speed<\/td><td>m\/s<\/td><td>1.2\u00b10.2<\/td><\/tr>\n    <tr><td>18<\/td><td>Average closing speed<\/td><td>m\/s<\/td><td>0.6\u00b10.2<\/td><\/tr>\n    <tr><td>19<\/td><td>Rated operating voltage<\/td><td>V<\/td><td>AC\/DC220<\/td><\/tr>\n    <tr><td>20<\/td><td>SF6 gas rated pressure<\/td><td>MPa<\/td><td>0<\/td><\/tr>\n  <\/tbody>\n          <\/table>\n        <\/div>\n\n        <!-- 12kV Dimensions + drawing -->\n        <p class=\"block-title\">Outline &amp; mounting dimensions \u2014 ZW20-12F<\/p>\n        <p class=\"block-note\">\n          Outline and mounting dimensions for typical ZW20-12F pole-mounted installation.\n        <\/p>\n        <div class=\"dim-block\">\n          <figure class=\"dim-fig\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/XBRELE-ZW20-12f-Vacuum-circuit-breaker-installing-dimension.webp\"\n                 alt=\"ZW20-12F outline and mounting dimensions \u2013 XBRELE\">\n            <figcaption>ZW20-12F outline &amp; mounting dimensions for pole-mounted installation.<\/figcaption>\n          <\/figure>\n\n          <div class=\"dim-right\">\n            <div class=\"table-wrap\">\n              <table>\n                <thead>\n                  <tr>\n                    <th>Item<\/th><th>Symbol<\/th><th>Value (mm)<\/th><th>Note<\/th>\n                  <\/tr>\n                <\/thead>\n                <tbody>\n                  <tr><td>Overall height<\/td><td>H<\/td><td>\u2014<\/td><td>Overall height of breaker assembly<\/td><\/tr>\n                  <tr><td>Overall width<\/td><td>W<\/td><td>\u2014<\/td><td>Including phase spacing<\/td><\/tr>\n                  <tr><td>Mounting hole spacing (horizontal)<\/td><td>L1<\/td><td>\u2014<\/td><td>Base horizontal bolt distance<\/td><\/tr>\n                  <tr><td>Mounting hole spacing (vertical)<\/td><td>L2<\/td><td>\u2014<\/td><td>To match cross-arm or steel structure<\/td><\/tr>\n                  <tr><td>Mounting hole size<\/td><td>\u03a6<\/td><td>\u2014<\/td><td>Oval or round hole diameter<\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/div>\n\n            <div class=\"cta-right-col\">\n              <a href=\"#ct-popup-882\" class=\"cta-btn\">\n                Request a Quote from XBRELE\n              <\/a>\n            <\/div>\n          <\/div>\n        <\/div>\n\n      <\/div><!-- \/panel-card -->\n    <\/div><!-- \/zw20-12 -->\n\n  <\/div>\n\n  <script>\n    (function(){\n      const root = document.querySelector('#sec3-zw20-tech');\n      if(!root) return;\n      const tabs = root.querySelectorAll('.tab-btn');\n      const panels = root.querySelectorAll('.tab-content');\n\n      tabs.forEach(tab => {\n        tab.addEventListener('click', () => {\n          const target = tab.getAttribute('data-tab');\n          tabs.forEach(t => t.classList.remove('active'));\n          panels.forEach(p => p.classList.remove('active'));\n          tab.classList.add('active');\n          root.querySelector('#'+target).classList.add('active');\n        });\n      });\n    })();\n  <\/script>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-c3c8ec5\" data-block-id=\"c3c8ec5\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-c3c8ec5-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-6a50f3c\" data-v=\"4\" data-block-id=\"6a50f3c\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-6a50f3c-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-6a50f3c-inner-blocks\">\n<section id=\"sec4-zw20-features\" style=\"background:#ffffff;padding:90px 0 100px;\">\n  <style>\n    #sec4-zw20-features{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec4-zw20-features .features-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec4-zw20-features .sec-header{\n      max-width:820px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec4-zw20-features .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec4-zw20-features h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec4-zw20-features .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec4-zw20-features .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n    }\n    #sec4-zw20-features .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:22px 22px 24px;\n      box-shadow:0 14px 32px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n    #sec4-zw20-features .card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#0F172A;\n    }\n    #sec4-zw20-features .card .tag{\n      display:inline-flex;\n      align-items:center;\n      justify-content:flex-start;\n      padding:3px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      background:#0F172A;\n      color:#E5E7EB;\n      margin-bottom:12px;\n    }\n    #sec4-zw20-features .card p{\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n      margin:0 0 10px;\n    }\n    #sec4-zw20-features .card ul{\n      list-style:none;\n      padding:0;\n      margin:6px 0 0;\n      font-size:14px;\n      color:#374151;\n    }\n    #sec4-zw20-features .card li{\n      position:relative;\n      padding-left:16px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec4-zw20-features .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    @media(max-width:1000px){\n      #sec4-zw20-features .grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:690px){\n      #sec4-zw20-features .features-shell{padding:0 18px;}\n      #sec4-zw20-features .grid{\n        grid-template-columns:1fr;\n      }\n      #sec4-zw20-features h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"features-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Configuration &amp; options<\/div>\n      <h2>Protection, control and automation around the ZW20 series<\/h2>\n      <p>\n        ZW20 outdoor vacuum reclosers can be combined with protection relays, CTs\/VTs and\n        communication devices to form complete pole-mounted switching and automation solutions\n        for distribution networks.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- Card 1 -->\n      <article class=\"card\">\n        <span class=\"tag\">Protection<\/span>\n        <h3>Protection &amp; measuring combinations<\/h3>\n        <p>\n          Build a complete protection scheme around the ZW20 using your preferred relays\n          and instrument transformers.\n        <\/p>\n        <ul>\n          <li>Feeder over-current and earth-fault protection<\/li>\n          <li>Directional \/ non-directional protection according to system design<\/li>\n          <li>Integrated CTs for metering and protection functions<\/li>\n          <li>Support for recloser curves and sectionalizing logic<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2 -->\n      <article class=\"card\">\n        <span class=\"tag\">Control<\/span>\n        <h3>Operating &amp; control options<\/h3>\n        <p>\n          Flexible operating configurations to match manual, local and remote control requirements.\n        <\/p>\n        <ul>\n          <li>Spring operating mechanism with motor charging<\/li>\n          <li>Local\/remote control selector with clear position indication<\/li>\n          <li>AUX contacts for SCADA status feedback (open\/close\/ready)<\/li>\n          <li>Compatible with pole-mounted control cabinets and RTUs<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3 -->\n      <article class=\"card\">\n        <span class=\"tag\">Automation<\/span>\n        <h3>Distribution automation &amp; communication<\/h3>\n        <p>\n          When combined with suitable controllers, ZW20 breakers can be used in\n          automated distribution systems and smart grid projects.\n        <\/p>\n        <ul>\n          <li>Support for common protocols via external IEDs (Modbus, IEC 60870-5-104, etc.)<\/li>\n          <li>Remote open\/close and status monitoring through SCADA<\/li>\n          <li>Fault location, isolation and service restoration (FLISR) schemes<\/li>\n          <li>Customized wiring and terminal arrangements on request<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-f2725ff\" data-block-id=\"f2725ff\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-f2725ff-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-0372a37\" data-v=\"4\" data-block-id=\"0372a37\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-0372a37-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-0372a37-inner-blocks\">\n<section id=\"sec5-zw20-quality\" style=\"background:#0B1220;padding:72px 0 78px;color:#E5E7EB;\">\n  <style>\n    #sec5-zw20-quality{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec5-zw20-quality .quality-shell{\n      max-width:1500px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec5-zw20-quality .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec5-zw20-quality .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec5-zw20-quality h2{\n      font-size:26px;\n      margin:0 0 8px;\n      color:#F9FAFB;\n    }\n    #sec5-zw20-quality .sec-header p{\n      margin:0;\n      font-size:14px;\n      color:#CBD5F5;\n      line-height:1.7;\n    }\n\n    #sec5-zw20-quality .grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.2fr) minmax(0,1.05fr);\n      gap:28px;\n      align-items:flex-start;\n    }\n\n    \/* Left: process steps *\/\n    #sec5-zw20-quality .process-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:radial-gradient(circle at top left,rgba(56,189,248,.14) 0,rgba(15,23,42,.98) 36%,#020617 100%);\n      padding:22px 22px 24px;\n      box-shadow:0 22px 52px rgba(15,23,42,.9);\n    }\n    #sec5-zw20-quality .process-card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#E5F0FF;\n    }\n    #sec5-zw20-quality .process-card p{\n      font-size:13.5px;\n      color:#CBD5F5;\n      line-height:1.75;\n      margin:0 0 14px;\n    }\n    #sec5-zw20-quality .step-list{\n      list-style:none;\n      margin:0;\n      padding:0;\n      display:flex;\n      flex-direction:column;\n      gap:10px;\n    }\n    #sec5-zw20-quality .step{\n      display:grid;\n      grid-template-columns:auto minmax(0,1fr);\n      gap:8px 12px;\n      align-items:flex-start;\n    }\n    #sec5-zw20-quality .step-badge{\n      width:24px;\n      height:24px;\n      border-radius:999px;\n      border:1px solid rgba(148,163,184,.7);\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      font-size:11px;\n      font-weight:600;\n      color:#E5E7EB;\n      background:rgba(15,23,42,.85);\n      flex-shrink:0;\n    }\n    #sec5-zw20-quality .step h4{\n      font-size:13.5px;\n      margin:1px 0 3px;\n      color:#F9FAFB;\n    }\n    #sec5-zw20-quality .step p{\n      font-size:12.5px;\n      margin:0;\n      color:#CBD5F5;\n      line-height:1.7;\n    }\n\n    \/* Right: compact QA block *\/\n    #sec5-zw20-quality .qa-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:rgba(15,23,42,.96);\n      padding:20px 20px 22px;\n      box-shadow:0 22px 52px rgba(15,23,42,.8);\n    }\n    #sec5-zw20-quality .qa-section{\n      & {}\n    }\n    #sec5-zw20-quality .qa-label{\n      font-size:11px;\n      letter-spacing:.14em;\n      text-transform:uppercase;\n      color:#93C5FD;\n      margin-bottom:3px;\n    }\n    #sec5-zw20-quality .qa-card h3{\n      font-size:15px;\n      margin:0 0 4px;\n      color:#E5F0FF;\n    }\n    #sec5-zw20-quality .qa-card p{\n      font-size:13px;\n      color:#CBD5F5;\n      margin:0 0 4px;\n      line-height:1.65;\n    }\n    #sec5-zw20-quality .qa-block{\n      margin-top:10px;\n      padding-top:10px;\n      border-top:1px solid rgba(148,163,184,.35);\n    }\n    #sec5-zw20-quality .qa-block:first-of-type{\n      margin-top:6px;\n      padding-top:0;\n      border-top:none;\n    }\n    #sec5-zw20-quality .qa-block h4{\n      font-size:13.5px;\n      margin:0 0 3px;\n      color:#E5F0FF;\n    }\n    #sec5-zw20-quality .qa-block ul{\n      list-style:none;\n      padding:0;\n      margin:0;\n      font-size:12.5px;\n      color:#E5E7EB;\n    }\n    #sec5-zw20-quality .qa-block li{\n      position:relative;\n      padding-left:12px;\n      margin-bottom:2px;\n      line-height:1.6;\n    }\n    #sec5-zw20-quality .qa-block li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:7px;\n      width:5px;\n      height:5px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n    #sec5-zw20-quality .qa-note{\n      font-size:12px;\n      color:#9CA3AF;\n      margin-top:4px;\n    }\n\n    @media(max-width:1000px){\n      #sec5-zw20-quality .grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec5-zw20-quality .quality-shell{padding:0 18px;}\n      #sec5-zw20-quality h2{font-size:22px;}\n    }\n  <\/style>\n\n  <div class=\"quality-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Manufacturing &amp; quality control<\/div>\n      <h2>How XBRELE builds reliable ZW20 outdoor vacuum circuit breakers<\/h2>\n      <p>\n        Behind every ZW20 unit there is a controlled manufacturing flow \u2013 from embedded pole casting\n        to routine testing \u2013 designed to ensure long-term reliability on harsh outdoor lines.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- LEFT: process flow -->\n      <article class=\"process-card\">\n        <h3>From embedded pole to finished breaker<\/h3>\n        <p>\n          XBRELE manufactures the vacuum interrupter pole assemblies, operating mechanism and housing\n          in a coordinated process. Each step is monitored and recorded for traceability of every ZW20 unit.\n        <\/p>\n\n        <ul class=\"step-list\">\n          <li class=\"step\">\n            <div class=\"step-badge\">01<\/div>\n            <div>\n              <h4>Vacuum interrupter &amp; pole assembly<\/h4>\n              <p>Vacuum interrupters are checked for stroke, over-travel and resistance, then built into the solid pole.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">02<\/div>\n            <div>\n              <h4>Solid insulation casting &amp; curing<\/h4>\n              <p>Epoxy insulation is degassed, poured and cured to form a compact embedded pole resistant to tracking.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">03<\/div>\n            <div>\n              <h4>Mechanism integration &amp; adjustment<\/h4>\n              <p>The spring mechanism is assembled, lubricated and tuned so speeds, timing and bounce meet ZW20 limits.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">04<\/div>\n            <div>\n              <h4>Final assembly &amp; sealing<\/h4>\n              <p>Poles, CTs, terminals and enclosure parts are combined into a sealed outdoor body with anti-corrosion coating.<\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">05<\/div>\n            <div>\n              <h4>Routine testing &amp; inspection<\/h4>\n              <p>Each breaker passes electrical, mechanical and dielectric tests before packing and shipment.<\/p>\n            <\/div>\n          <\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- RIGHT: compact QA -->\n      <section class=\"qa-card\">\n        <div class=\"qa-section\">\n          <div class=\"qa-label\">Electrical &amp; dielectric tests<\/div>\n          <h3>Routine tests for every ZW20<\/h3>\n          <p>Electrical routine tests verify insulation level and switching performance.<\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Insulation &amp; switching verification<\/h4>\n          <ul>\n            <li>Power-frequency withstand between phases and to earth<\/li>\n            <li>Lightning impulse withstand on sample basis<\/li>\n            <li>Contact resistance check for each main circuit<\/li>\n            <li>Mechanical operating tests for O \/ CO sequences<\/li>\n          <\/ul>\n          <p class=\"qa-note\">Routine-test records can be supplied with the shipment if required.<\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Mechanical reliability<\/h4>\n          <ul>\n            <li>Type-test verification of 10,000 mechanical operations<\/li>\n            <li>Check of opening \/ closing speeds within limits<\/li>\n            <li>Control of closing bounce time and pole synchronism<\/li>\n            <li>Environmental checks for lubrication and low-temperature duty<\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Documentation &amp; traceability<\/h4>\n          <ul>\n            <li>Type-test reports and routine-test certificates<\/li>\n            <li>Factory inspection records with serial number traceability<\/li>\n            <li>Outline drawings &amp; terminal diagrams in editable format<\/li>\n            <li>Recommended maintenance guidelines for field crews<\/li>\n          <\/ul>\n          <p class=\"qa-note\">FAT \/ QAP \/ ITP witness testing can be arranged for utility or EPC projects.<\/p>\n        <\/div>\n      <\/section>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-fdbcf20\" data-block-id=\"fdbcf20\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-fdbcf20-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-6ff6a89\" data-v=\"4\" data-block-id=\"6ff6a89\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-6ff6a89-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-6ff6a89-inner-blocks\">\n<section id=\"sec6-zw20-delivery\" style=\"background:#FFFFFF;padding:86px 0 96px;color:#0F172A;\">\n  <style>\n    #sec6-zw20-delivery{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec6-zw20-delivery .delivery-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec6-zw20-delivery .sec-header{\n      max-width:820px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec6-zw20-delivery .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec6-zw20-delivery h2{\n      font-size:26px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec6-zw20-delivery .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec6-zw20-delivery .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:22px;\n      align-items:stretch;\n    }\n    #sec6-zw20-delivery .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:20px 20px 22px;\n      box-shadow:0 14px 32px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n    }\n    #sec6-zw20-delivery .card h3{\n      font-size:16px;\n      margin:0 0 6px;\n      color:#0F172A;\n    }\n    #sec6-zw20-delivery .card p{\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n      margin:0 0 8px;\n    }\n    #sec6-zw20-delivery .card ul{\n      list-style:none;\n      padding:0;\n      margin:4px 0 0;\n      font-size:13.5px;\n      color:#374151;\n    }\n    #sec6-zw20-delivery .card li{\n      position:relative;\n      padding-left:14px;\n      margin-bottom:4px;\n      line-height:1.7;\n    }\n    #sec6-zw20-delivery .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    #sec6-zw20-delivery .cta-row{\n      margin-top:30px;\n      display:flex;\n      justify-content:center;\n    }\n    #sec6-zw20-delivery .cta-btn{\n      display:inline-flex;\n      align-items:center;\n      justify-content:center;\n      padding:11px 30px;\n      border-radius:999px;\n      border:none;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:14px;\n      font-weight:600;\n      text-decoration:none;\n      letter-spacing:.03em;\n      box-shadow:0 12px 28px rgba(15,23,42,.18);\n      cursor:pointer;\n      transition:background .2s ease, transform .2s ease, box-shadow .2s ease;\n    }\n    #sec6-zw20-delivery .cta-btn:hover{\n      background:#1E293B;\n      transform:translateY(-1px);\n      box-shadow:0 16px 36px rgba(15,23,42,.25);\n    }\n\n    @media(max-width:1000px){\n      #sec6-zw20-delivery .grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:690px){\n      #sec6-zw20-delivery .delivery-shell{padding:0 18px;}\n      #sec6-zw20-delivery .grid{\n        grid-template-columns:1fr;\n      }\n      #sec6-zw20-delivery h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"delivery-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Delivery, export packing &amp; support<\/div>\n      <h2>Lead time and project support for ZW20-12F outdoor vacuum reclosers<\/h2>\n      <p>\n        XBRELE supplies ZW20-12F outdoor vacuum reclosers and sectionalizers for utility and EPC\n        projects worldwide, with export-ready packing, flexible lead times and technical support\n        for tender and execution stages.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- Card 1: Lead time & MOQ -->\n      <article class=\"card\">\n        <h3>Lead time &amp; minimum order<\/h3>\n        <p>\n          Standard ZW20-12F configurations can usually be produced within a few weeks after\n          order confirmation and technical clarification.\n        <\/p>\n        <ul>\n          <li>Typical lead time: about 20\u201330 days for standard units<\/li>\n          <li>Small batches for pilot projects are acceptable<\/li>\n          <li>Mixed orders with other XBRELE VCB series can be combined in one shipment<\/li>\n          <li>Urgent requirements can be discussed case by case<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2: Packing & logistics -->\n      <article class=\"card\">\n        <h3>Export packing &amp; logistics<\/h3>\n        <p>\n          ZW20-12F reclosers are packed for long-distance sea or land transport, with protection\n          against vibration, moisture and corrosion.\n        <\/p>\n        <ul>\n          <li>Strong export wooden cases with internal fixing of the breaker<\/li>\n          <li>Circuit breaker, controller and CTs packed with clear labels<\/li>\n          <li>Support for FOB, CIF or door-to-port delivery terms<\/li>\n          <li>Shipping documents and packing list prepared according to client\u2019s instructions<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3: Engineering & project support -->\n      <article class=\"card\">\n        <h3>Engineering &amp; project support<\/h3>\n        <p>\n          XBRELE can assist panel builders, OEMs and utilities during selection, tender preparation\n          and project execution for ZW20-12F applications.\n        <\/p>\n        <ul>\n          <li>Support with single-line diagrams and equipment schedules<\/li>\n          <li>Outline drawings, wiring diagrams and data sheets for approval<\/li>\n          <li>Type-test reports and routine-test certificates for documentation<\/li>\n          <li>FAT \/ QAP \/ ITP witness testing can be arranged when required<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n\n    <div class=\"cta-row\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Discuss Your ZW20-12F Project with XBRELE\n      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-aa0c935\" data-block-id=\"aa0c935\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-aa0c935-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-d4965af\" data-v=\"4\" data-block-id=\"d4965af\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-d4965af-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-d4965af-inner-blocks\">\n<section id=\"sec7-zw20-faq\" style=\"padding:90px 0 110px;background:#ffffff;\">\n  <style>\n    #sec7-zw20-faq{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec7-zw20-faq .faq-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec7-zw20-faq .faq-header{\n      max-width:780px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec7-zw20-faq .faq-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec7-zw20-faq h2{\n      font-size:28px;\n      margin:0 0 12px;\n      color:#0F172A;\n    }\n    #sec7-zw20-faq .faq-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec7-zw20-faq .faq-grid{\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:18px 26px;\n      align-items:flex-start;\n    }\n\n    #sec7-zw20-faq details{\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:14px 16px;\n      transition:box-shadow .2s ease, border-color .2s ease, background .2s ease;\n    }\n    #sec7-zw20-faq details[open]{\n      background:#FFFFFF;\n      border-color:#CBD5F5;\n      box-shadow:0 12px 30px rgba(15,23,42,.06);\n    }\n    #sec7-zw20-faq summary{\n      list-style:none;\n      cursor:pointer;\n      font-size:15px;\n      font-weight:600;\n      color:#111827;\n      display:flex;\n      align-items:flex-start;\n      justify-content:space-between;\n      gap:10px;\n    }\n    #sec7-zw20-faq summary::-webkit-details-marker{display:none;}\n    #sec7-zw20-faq .faq-icon{\n      flex-shrink:0;\n      width:18px;\n      height:18px;\n      border-radius:999px;\n      border:1px solid #D1D5DB;\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      font-size:11px;\n      color:#6B7280;\n      margin-top:2px;\n    }\n    #sec7-zw20-faq details[open] .faq-icon{\n      background:#2563EB;\n      color:#FFFFFF;\n      border-color:#2563EB;\n    }\n    #sec7-zw20-faq .faq-answer{\n      margin-top:10px;\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n    #sec7-zw20-faq .faq-answer a{\n      color:#2563EB;\n      text-decoration:none;\n    }\n    #sec7-zw20-faq .faq-answer a:hover{\n      text-decoration:underline;\n    }\n\n    @media(max-width:1000px){\n      #sec7-zw20-faq .faq-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec7-zw20-faq .faq-shell{padding:0 18px;}\n      #sec7-zw20-faq h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"faq-shell\">\n    <div class=\"faq-header\">\n      <div class=\"faq-kicker\">FAQ \u00b7 ZW20 Series<\/div>\n      <h2>Frequently asked questions about the ZW20 vacuum circuit breaker<\/h2>\n      <p>\n        Below are typical questions from utilities, EPC contractors and distributors when selecting the\n        ZW20 vacuum circuit breaker for 12&nbsp;kV overhead distribution networks and recloser projects.\n      <\/p>\n    <\/div>\n\n    <div class=\"faq-grid\">\n      <!-- Q1 -->\n      <details open>\n        <summary>\n          <span>What is the main difference between ZW20 and ZW32?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Both products are outdoor medium-voltage vacuum circuit breakers, but ZW20 is typically used as a\n          pole-mounted switching point on 12&nbsp;kV lines and can be configured as an automatic recloser.\n          ZW32 is a more compact pole-mounted breaker platform with different ratings and outline dimensions.\n          When planning a project, the ZW20 vacuum circuit breaker is often selected where an integrated\n          control cubicle and recloser functions are required.\n        <\/div>\n      <\/details>\n\n      <!-- Q2 -->\n      <details>\n        <summary>\n          <span>Can the ZW20 vacuum circuit breaker be supplied as an automatic recloser?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Yes. By adding a suitable controller, auxiliary CTs\/VTs and wiring, the ZW20 vacuum circuit breaker\n          can be configured as an automatic recloser with programmable protection curves and reclosing\n          sequences. XBRELE can provide a complete ZW20 recloser package or cooperate with the customer\u2019s\n          specified controller brand.\n        <\/div>\n      <\/details>\n\n      <!-- Q3 -->\n      <details>\n        <summary>\n          <span>Where is the ZW20 vacuum circuit breaker typically installed?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          The ZW20 vacuum circuit breaker is installed on concrete or steel poles, usually at feeder\n          branches, section points or near pole-mounted transformers. Designers use the outline &amp;\n          mounting dimensions on this page to match cross-arms, brackets and hardware for the 12&nbsp;kV\n          overhead line.\n        <\/div>\n      <\/details>\n\n      <!-- Q4 -->\n      <details>\n        <summary>\n          <span>What protection functions can be implemented with ZW20?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          With a suitable protection relay or recloser controller, ZW20 can provide phase over-current,\n          earth-fault protection, sensitive earth-fault, cold-load pick-up and other functions.\n          CTs\/VTs mounted with the ZW20 vacuum circuit breaker supply the necessary signals for metering\n          and protection.\n        <\/div>\n      <\/details>\n\n      <!-- Q5 -->\n      <details>\n        <summary>\n          <span>What documentation and test reports are available for ZW20?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          XBRELE can provide outline drawings, terminal diagrams, type-test reports, routine-test reports\n          and factory inspection records for the ZW20 vacuum circuit breaker. For utility or EPC projects,\n          QAP\/ITP documents and FAT witness testing can also be arranged according to the specification.\n        <\/div>\n      <\/details>\n\n      <!-- Q6 -->\n      <details>\n        <summary>\n          <span>What is the typical delivery time for the ZW20 vacuum circuit breaker?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          For standard 12&nbsp;kV ZW20 configurations, the typical lead time is about 15\u201325 days after\n          order confirmation. For customized designs with special controllers, CTs\/VTs or testing\n          requirements, lead time is usually 25\u201335 days depending on quantity and project scope.\n        <\/div>\n      <\/details>\n\n      <!-- Q7 \u00b7 external link -->\n      <details>\n        <summary>\n          <span>Which international standards are used as reference for ZW20 testing?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          ZW20 outdoor vacuum circuit breakers are designed and type tested with reference to the IEC&nbsp;62271\n          series for high-voltage switchgear, in particular IEC&nbsp;62271-100 for high-voltage AC\n          circuit-breakers. For more information about the scope and latest edition of IEC&nbsp;62271-100,\n          you can refer to the official IEC webstore page\n          <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"Dofollow noopener\">\n            IEC 62271-100\n          <\/a>.\n        <\/div>\n      <\/details>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>MV &amp; HV VACUUM CIRCUIT BREAKERS ZW20 Vacuum Circuit Breaker for 12kV Overhead Distribution Networks XBRELE designs and manufactures outdoor ZW20 vacuum circuit breakers for 12&nbsp;kV medium-voltage power systems, providing reliable protection and automation for overhead distribution networks. ZW20 series can be configured as automatic reclosers for feeder and transformer protection. XBRELE supplies the ZW20 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1071,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1135","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"bottom","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1135","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/comments?post=1135"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1135\/revisions"}],"predecessor-version":[{"id":1165,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1135\/revisions\/1165"}],"up":[{"embeddable":true,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1071"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/media?parent=1135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}