{"id":1199,"date":"2025-11-21T17:53:59","date_gmt":"2025-11-21T17:53:59","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1199"},"modified":"2025-11-22T10:10:08","modified_gmt":"2025-11-22T10:10:08","slug":"ckg-vacuum-contactor","status":"publish","type":"page","link":"https:\/\/xbrele.com\/pt\/vacuum-contactor\/ckg-vacuum-contactor\/","title":{"rendered":"Contator a v\u00e1cuo CKG"},"content":{"rendered":"\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-84c25ed\" data-block-id=\"84c25ed\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-84c25ed-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-6660aba\" data-v=\"4\" data-block-id=\"6660aba\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-6660aba-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-6660aba-inner-blocks\">\n<section id=\"sec1-ckg-hero\" style=\"position:relative;overflow:hidden;background:radial-gradient(circle at top left,#0f172a 0,#020617 55%,#020617 100%);color:#e5e7eb;padding:200px 0 128px;\">\n  <style>\n    #sec1-ckg-hero{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec1-ckg-hero .ckg-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec1-ckg-hero .ckg-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:48px;\n      align-items:center;\n    }\n    #sec1-ckg-hero .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38bdf8;\n      margin-bottom:10px;\n    }\n    #sec1-ckg-hero h1{\n      font-size:40px;\n      line-height:1.1;\n      letter-spacing:-.03em;\n      margin:0 0 14px;\n      color:#f9fafb;\n    }\n    #sec1-ckg-hero p.sub{\n      max-width:660px;\n      font-size:16px;\n      line-height:1.75;\n      margin:0 0 20px;\n      color:#cbd5f5;\n    }\n    \/* Badges *\/\n    #sec1-ckg-hero .badges{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:22px 0 32px;\n    }\n    #sec1-ckg-hero .badge{\n      padding:6px 12px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid rgba(148,163,184,.55);\n      background:rgba(15,23,42,.45);\n      backdrop-filter:blur(14px);\n      color:#e5e7eb;\n    }\n    \/* Right card *\/\n    #sec1-ckg-hero .hero-card{\n      position:relative;\n      border-radius:20px;\n      padding:22px 22px 18px;\n      background:radial-gradient(circle at top left,rgba(56,189,248,.20) 0,rgba(15,23,42,.95) 36%,rgba(15,23,42,1) 100%);\n      border:1px solid rgba(148,163,184,.4);\n      box-shadow:0 18px 45px rgba(15,23,42,.9);\n      color:#e5e7eb;\n    }\n    #sec1-ckg-hero .hero-card h3{\n      font-size:15px;\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      color:#bae6fd;\n      margin:0 0 10px;\n    }\n    #sec1-ckg-hero .hero-card p{\n      font-size:13px;\n      line-height:1.7;\n      color:#cbd5f5;\n      margin:0 0 16px;\n    }\n    #sec1-ckg-hero .spec-grid{\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:12px 20px;\n      font-size:12px;\n    }\n    .spec-label{\n      text-transform:uppercase;\n      letter-spacing:.12em;\n      color:#9ca3af;\n      margin-bottom:2px;\n      font-size:11px;\n    }\n    .spec-value{\n      font-weight:500;\n      color:#e5e7eb;\n    }\n\n    @media(max-width:1000px){\n      #sec1-ckg-hero .ckg-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec1-ckg-hero h1{font-size:30px;}\n      #sec1-ckg-hero .ckg-shell{padding:0 18px;}\n    }\n  <\/style>\n\n  <div class=\"ckg-shell\">\n    <div class=\"ckg-grid\">\n\n      <!-- Left content -->\n      <div>\n        <div class=\"kicker\">Vacuum Contactors \u00b7 Series<\/div>\n        <h1>CKG Vacuum Contactor Series<\/h1>\n\n        <p class=\"sub\">\n          XBRELE CKG vacuum contactor series is developed for medium voltage motor, transformer and capacitor bank\n          applications. CKG3-7.2 and CKG4-12 contactors offer reliable vacuum interruption, compact construction and\n          flexible control circuits, making them suitable for OEM switchgear panels and retrofit projects in 7.2&nbsp;kV\n          and 12&nbsp;kV distribution networks.\n        <\/p>\n\n        <div class=\"badges\">\n          <span class=\"badge\">7.2kV<\/span>\n          <span class=\"badge\">12kV<\/span>\n          <span class=\"badge\">Motor Duty<\/span>\n          <span class=\"badge\">Capacitor Duty<\/span>\n          <span class=\"badge\">Medium Voltage<\/span>\n          <span class=\"badge\">Indoor Panels<\/span>\n        <\/div>\n      <\/div>\n\n      <!-- Right card -->\n      <aside class=\"hero-card\">\n        <h3>Key Ratings Overview<\/h3>\n        <p>\n          The CKG3-7.2 and CKG4-12 ranges cover typical medium voltage switchgear duties, including frequent\n          switching of motors, transformers and capacitor banks. Use the technical tables and outline drawings\n          below as a reference for engineering design and panel layout.\n        <\/p>\n\n        <div class=\"spec-grid\">\n          <div>\n            <div class=\"spec-label\">Voltage levels<\/div>\n            <div class=\"spec-value\">7.2kV \/ 12kV<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Typical duty<\/div>\n            <div class=\"spec-value\">Motors \/ Transformers \/ Capacitors<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Mechanical life*<\/div>\n            <div class=\"spec-value\">Up to 500k operations<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Electrical life (AC-3)*<\/div>\n            <div class=\"spec-value\">Up to 250k operations<\/div>\n          <\/div>\n        <\/div>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-e19fd9c\" data-block-id=\"e19fd9c\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-e19fd9c-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-879af80\" data-v=\"4\" data-block-id=\"879af80\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-879af80-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-879af80-inner-blocks\">\n<section id=\"sec2-ckg-overview\" style=\"background:#ffffff;padding:90px 0 105px;color:#0f172a;\">\n  <style>\n    #sec2-ckg-overview{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec2-ckg-overview .ckg-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec2-ckg-overview .overview-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.4fr) minmax(0,1fr);\n      gap:52px;\n      align-items:center;\n    }\n    #sec2-ckg-overview .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38bdf8;\n      margin-bottom:10px;\n    }\n    #sec2-ckg-overview h2{\n      font-size:28px;\n      margin:0 0 14px;\n      color:#0f172a;\n    }\n    #sec2-ckg-overview p{\n      font-size:16px;\n      line-height:1.85;\n      margin:0 0 16px;\n      color:#4b5563;\n    }\n    #sec2-ckg-overview .apps-box{\n      background:#f9fafb;\n      padding:22px 24px 20px;\n      border-radius:18px;\n      border:1px solid #e5e7eb;\n    }\n    #sec2-ckg-overview .apps-box h3{\n      font-size:15px;\n      margin:0 0 12px;\n      text-transform:uppercase;\n      letter-spacing:.14em;\n      color:#6b7280;\n    }\n    #sec2-ckg-overview ul{\n      list-style:none;\n      padding:0;\n      margin:0;\n      display:grid;\n      gap:10px;\n      font-size:14px;\n      color:#374151;\n    }\n    #sec2-ckg-overview ul li{\n      position:relative;\n      padding-left:16px;\n      line-height:1.7;\n    }\n    #sec2-ckg-overview ul li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38bdf8;\n    }\n\n    @media(max-width:1000px){\n      #sec2-ckg-overview .overview-grid{\n        grid-template-columns:1fr;\n      }\n    }\n  <\/style>\n\n  <div class=\"ckg-shell\">\n    <div class=\"overview-grid\">\n\n      <!-- LEFT TEXT -->\n      <div>\n        <div class=\"kicker\">Series overview<\/div>\n        <h2>CKG vacuum contactor engineered for medium voltage switching<\/h2>\n\n        <p>\n          The CKG vacuum contactor series covers <strong>CKG3-7.2<\/strong> and <strong>CKG4-12<\/strong> models designed for\n          medium voltage motor, transformer and capacitor bank switching. Each unit adopts a compact\n          vacuum interrupter assembly combined with reliable electromagnetic or permanent-magnet\n          operating mechanisms, suitable for frequent duty cycles in OEM switchgear and industrial\n          distribution systems.\n        <\/p>\n\n        <p>\n          The interrupter and arc-quenching components are arranged to provide stable dielectric\n          performance under repeated operations, while coil options (AC\/DC) give panel builders\n          flexibility for control circuit design. Rated currents extend from standard\n          400\u2013630A units up to <strong>800A<\/strong>, <strong>1000A<\/strong> and <strong>1250A<\/strong> high-current\n          versions in the CKG4 range, meeting different feeder and motor-starting requirements.\n        <\/p>\n\n        <p>\n          Specialized variants such as <strong>CKG4-1600\/12<\/strong>, <strong>CKG4-2000\/12<\/strong>, capacitor-switching models and\n          mechanical interlocking configurations give EPC integrators a unified family platform for\n          diverse MV applications. Installation and maintenance follow standard indoor panel practices,\n          ensuring consistent performance across long-term operation.\n        <\/p>\n\n        <p style=\"margin-top:14px;font-size:14px;color:#4b5563;\">\n          For a broader view of XBRELE\u2019s medium-voltage switching portfolio, please visit the\n          <a href=\"https:\/\/xbrele.com\/vacuum-contactor\/\" style=\"color:#2563EB;text-decoration:none;\">\n            Vacuum Contactor pillar page\n          <\/a>.\n        <\/p>\n      <\/div>\n\n      <!-- RIGHT BOX -->\n      <aside class=\"apps-box\">\n        <h3>Typical applications<\/h3>\n        <ul>\n          <li>Motor starting &amp; stopping (AC-3 \/ AC-4 duty)<\/li>\n          <li>Transformer switching and feeder control<\/li>\n          <li>Capacitor bank switching &amp; reactive compensation<\/li>\n          <li>Industrial MV switchgear &amp; OEM panel builders<\/li>\n          <li>Pump stations, mining, steel, petrochemical loads<\/li>\n        <\/ul>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-8e0ab78\" data-block-id=\"8e0ab78\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-8e0ab78-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-279e092\" data-v=\"4\" data-block-id=\"279e092\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-279e092-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-279e092-inner-blocks\">\n<section id=\"sec3-ckg-tech\" style=\"padding:90px 0;background:#F9FAFB;\">\n  <style>\n    #sec3-ckg-tech{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec3-ckg-tech .tech-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec3-ckg-tech .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec3-ckg-tech .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec3-ckg-tech h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-ckg-tech .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    \/* TAB Row *\/\n    #sec3-ckg-tech .tab-row{\n      display:flex;\n      flex-wrap:wrap;\n      justify-content:center;\n      gap:10px;\n      margin:34px 0 32px;\n    }\n    #sec3-ckg-tech .tab-btn{\n      padding:10px 22px;\n      font-size:14px;\n      font-weight:600;\n      background:#E5E7EB;\n      border-radius:999px;\n      cursor:pointer;\n      border:1px solid #D1D5DB;\n      transition:all .25s ease;\n      color:#0F172A;\n      white-space:nowrap;\n    }\n    #sec3-ckg-tech .tab-btn:hover{\n      background:#DDE3E9;\n    }\n    #sec3-ckg-tech .tab-btn.active{\n      background:#0F172A;\n      color:#F9FAFB;\n      border-color:#0F172A;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n    }\n\n    \/* Panels *\/\n    #sec3-ckg-tech .tab-content{\n      display:none;\n      animation:fadeIn .25s ease;\n    }\n    #sec3-ckg-tech .tab-content.active{\n      display:block;\n    }\n    @keyframes fadeIn{\n      from{opacity:0;transform:translateY(6px);}\n      to{opacity:1;transform:translateY(0);}\n    }\n\n    \/* Panel layout *\/\n    #sec3-ckg-tech .panel-card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:24px 22px 30px;\n      box-shadow:0 14px 32px rgba(15,23,42,.05);\n    }\n    #sec3-ckg-tech .panel-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.15fr) minmax(0,1.1fr);\n      gap:22px;\n      margin-bottom:24px;\n      align-items:flex-start;\n    }\n\n    \/* \u4e3b\u56fe gallery *\/\n    #sec3-ckg-tech .main-fig-large{\n      margin:0;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:10px;\n    }\n    #sec3-ckg-tech .main-fig-large img{\n      display:block;\n      width:100%;\n      max-height:320px;\n      object-fit:contain;\n    }\n    #sec3-ckg-tech .main-fig-large figcaption{\n      margin-top:8px;\n      font-size:12px;\n      color:#6B7280;\n      line-height:1.6;\n    }\n\n    #sec3-ckg-tech .thumb-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:10px;\n      margin-top:12px;\n    }\n    #sec3-ckg-tech .thumb-btn{\n      border-radius:10px;\n      border:1px solid #E5E7EB;\n      padding:4px;\n      background:#FFFFFF;\n      cursor:pointer;\n      transition:all .18s ease;\n    }\n    #sec3-ckg-tech .thumb-btn img{\n      display:block;\n      width:90px;\n      height:70px;\n      object-fit:contain;\n    }\n    #sec3-ckg-tech .thumb-btn.active{\n      border-color:#0F172A;\n      box-shadow:0 0 0 1px #0F172A,0 8px 18px rgba(15,23,42,.18);\n    }\n    #sec3-ckg-tech .thumb-btn:hover{\n      border-color:#0F172A;\n    }\n\n    #sec3-ckg-tech .panel-right h3{\n      font-size:16px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-ckg-tech .panel-right p{\n      font-size:14px;\n      line-height:1.8;\n      margin:0 0 10px;\n      color:#4B5563;\n    }\n    #sec3-ckg-tech .badge-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:8px 0 14px;\n    }\n    #sec3-ckg-tech .badge{\n      padding:4px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid #D1D5DB;\n      background:#F9FAFB;\n      color:#4B5563;\n    }\n\n    \/* tables *\/\n    #sec3-ckg-tech .block-title{\n      font-size:14px;\n      font-weight:600;\n      margin:4px 0 6px;\n      color:#111827;\n    }\n    #sec3-ckg-tech .block-note{\n      font-size:12px;\n      color:#6B7280;\n      margin:0 0 10px;\n    }\n    #sec3-ckg-tech .table-wrap{\n      width:100%;\n      overflow-x:auto;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      margin-bottom:18px;\n    }\n    #sec3-ckg-tech table{\n      width:100%;\n      border-collapse:collapse;\n      font-size:13px;\n      min-width:520px;\n    }\n    #sec3-ckg-tech thead{\n      background:#E5F0FF;\n    }\n    #sec3-ckg-tech th,\n    #sec3-ckg-tech td{\n      padding:8px 10px;\n      border-bottom:1px solid #E5E7EB;\n      text-align:left;\n      color:#111827;\n    }\n    #sec3-ckg-tech th{\n      font-size:12px;\n      text-transform:uppercase;\n      letter-spacing:.08em;\n      color:#374151;\n      font-weight:600;\n    }\n    #sec3-ckg-tech tbody tr:nth-child(odd){\n      background:#FFFFFF;\n    }\n    #sec3-ckg-tech tbody tr:nth-child(even){\n      background:#F9FAFB;\n    }\n    \/* NEW: Superscript fix for tables *\/\n    #sec3-ckg-tech sup{\n      font-size:75%;\n      line-height:0;\n      position:relative;\n      vertical-align:baseline;\n      top:-0.4em;\n    }\n\n    \/* Dimensions \u72ec\u7acb gallery *\/\n    #sec3-ckg-tech .dim-section{\n      margin-top:22px;\n    }\n    #sec3-ckg-tech .dim-main-fig{\n      margin:0;\n      border-radius:16px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:10px;\n    }\n    #sec3-ckg-tech .dim-main-fig img{\n      display:block;\n      width:100%;\n      max-height:420px;\n      object-fit:contain;\n    }\n    #sec3-ckg-tech .dim-main-fig figcaption{\n      margin-top:6px;\n      font-size:12px;\n      color:#6B7280;\n      line-height:1.6;\n    }\n    #sec3-ckg-tech .dim-thumb-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:10px;\n      margin-top:12px;\n    }\n    #sec3-ckg-tech .dim-thumb-btn{\n      border-radius:10px;\n      border:1px solid #D1D5DB;\n      padding:4px;\n      background:#F9FAFB;\n      cursor:pointer;\n      transition:all .18s ease;\n    }\n    #sec3-ckg-tech .dim-thumb-btn img{\n      display:block;\n      width:90px;\n      height:70px;\n      object-fit:contain;\n    }\n    #sec3-ckg-tech .dim-thumb-btn.active{\n      border-color:#0F172A;\n      background:#FFFFFF;\n      box-shadow:0 0 0 1px #0F172A,0 8px 18px rgba(15,23,42,.16);\n    }\n    #sec3-ckg-tech .dim-thumb-btn:hover{\n      border-color:#0F172A;\n    }\n\n    \/* CTA *\/\n    #sec3-ckg-tech .cta-right-col{\n      display:flex;\n      justify-content:center;\n      margin-top:26px;\n    }\n    #sec3-ckg-tech .cta-btn{\n      display:inline-block;\n      padding:12px 30px;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:15px;\n      font-weight:600;\n      border-radius:8px;\n      text-decoration:none;\n      letter-spacing:.03em;\n      transition:all .25s ease;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n      white-space:nowrap;\n    }\n    #sec3-ckg-tech .cta-btn:hover{\n      background:#1E293B;\n      box-shadow:0 14px 32px rgba(15,23,42,.25);\n      transform:translateY(-1px);\n    }\n\n    @media(max-width:1000px){\n      #sec3-ckg-tech .panel-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec3-ckg-tech .tech-shell{padding:0 18px;}\n      #sec3-ckg-tech h2{font-size:24px;}\n      #sec3-ckg-tech .thumb-btn img,\n      #sec3-ckg-tech .dim-thumb-btn img{\n        width:80px;\n        height:60px;\n      }\n    }\n  <\/style>\n\n  <div class=\"tech-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Technical data &amp; installation dimensions<\/div>\n      <h2>CKG3 &amp; CKG4 vacuum contactors \u2014 main ratings and outline drawings<\/h2>\n      <p>\n        Select a series below to view representative product photos, key electrical ratings and outline &amp;\n        mounting dimensions for engineering design and switchgear layout.\n      <\/p>\n    <\/div>\n\n    <div class=\"tab-row\">\n      <div class=\"tab-btn active\" data-tab=\"ckg3-7-2\">CKG3 \u00b7 7.2 kV Series<\/div>\n      <div class=\"tab-btn\" data-tab=\"ckg4-12-std\">CKG4 \u00b7 12 kV Standard &amp; Capacitor<\/div>\n      <div class=\"tab-btn\" data-tab=\"ckg4-12-special\">CKG4 \u00b7 12 kV Special Configurations<\/div>\n      <div class=\"tab-btn\" data-tab=\"ckg4-12-mech\">CKG4 \u00b7 12 kV Mechanical Interlocking<\/div>\n      <div class=\"tab-btn\" data-tab=\"ckg4-hi-current\">CKG4 \u00b7 High Current 12 kV (800\u20131250 A)<\/div>\n    <\/div>\n\n    <div id=\"ckg3-7-2\" class=\"tab-content active\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <div>\n            <figure class=\"main-fig-large\">\n              <img decoding=\"async\" id=\"ckg3-main-img\"\n                   src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-vacuum-contactor-standard-main.webp\"\n                   alt=\"XBRELE CKG3 7.2 kV indoor vacuum contactor standard type for motor and feeder switching\">\n              <figcaption id=\"ckg3-main-cap\">\n                CKG3-\u25a1\/7.2 standard 7.2&nbsp;kV indoor vacuum contactor for general motor and feeder switching.\n              <\/figcaption>\n            <\/figure>\n\n            <div class=\"thumb-row\">\n              <button class=\"thumb-btn js-photo-thumb active\"\n                      type=\"button\"\n                      data-target-img=\"#ckg3-main-img\"\n                      data-target-cap=\"#ckg3-main-cap\"\n                      data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-vacuum-contactor-standard-main.webp\"\n                      data-alt=\"XBRELE CKG3 7.2 kV indoor vacuum contactor standard type for motor and feeder switching\"\n                      data-caption=\"CKG3-\u25a1\/7.2 standard 7.2&nbsp;kV indoor vacuum contactor for general motor and feeder switching.\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-vacuum-contactor-standard-main.webp\"\n                     alt=\"CKG3-\u25a1\/7.2 standard vacuum contactor thumbnail\">\n              <\/button>\n\n              <button class=\"thumb-btn js-photo-thumb\"\n                      type=\"button\"\n                      data-target-img=\"#ckg3-main-img\"\n                      data-target-cap=\"#ckg3-main-cap\"\n                      data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-capacitor-switching-main.webp\"\n                      data-alt=\"XBRELE CKG3 7.2 kV back-to-back capacitor switching vacuum contactor with insulated poles\"\n                      data-caption=\"CKG3-\u25a1\/7.2F\u25a1\u25a1 back-to-back capacitor switching vacuum contactor with solid insulated poles, suitable for capacitor bank applications.\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-capacitor-switching-main.webp\"\n                     alt=\"CKG3-\u25a1\/7.2F\u25a1\u25a1 capacitor switching vacuum contactor thumbnail\">\n              <\/button>\n            <\/div>\n          <\/div>\n\n          <div class=\"panel-right\">\n            <h3>CKG3 7.2&nbsp;kV indoor vacuum contactor \u2014 overview<\/h3>\n            <p>\n              CKG3 7.2&nbsp;kV vacuum contactors are used in indoor MV switchgear and control equipment\n              with AC 50&nbsp;Hz, rated voltage up to 7.2&nbsp;kV and rated current up to 630&nbsp;A. They are\n              suitable for frequent switching of motors, transformers and capacitor banks in power systems.\n            <\/p>\n            <p>\n              The series adopts a reliable vacuum interrupter and operating mechanism with compact structure,\n              fast making and breaking, high dielectric strength and long mechanical &amp; electrical life.\n              In the CKG3-\u25a1\/7.2F\u25a1\u25a1 variant, the main circuit and contacts are optimised for back-to-back\n              capacitor bank switching.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">7.2kV<\/span>\n              <span class=\"badge\">Indoor<\/span>\n              <span class=\"badge\">Up to 630A<\/span>\n              <span class=\"badge\">Capacitor switching<\/span>\n            <\/div>\n            <p>\n              The table below summarises the main electrical ratings for the CKG3-\u25a1\/7.2 and\n              CKG3-\u25a1\/7.2F\u25a1\u25a1 vacuum contactors. Items marked \u201c(F\u25a1\u25a1 only)\u201d apply only to the\n              back-to-back capacitor switching type.\n            <\/p>\n          <\/div>\n        <\/div>\n\n        <p class=\"block-title\">Main technical parameters \u2014 CKG3 7.2&nbsp;kV series<\/p>\n        <p class=\"block-note\">\n          Ratings for CKG3-\u25a1\/7.2 standard and CKG3-\u25a1\/7.2F\u25a1\u25a1 back-to-back capacitor switching vacuum contactors.\n        <\/p>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th style=\"width:52px;\">No.<\/th>\n                <th>Item<\/th>\n                <th style=\"width:125px;\">Unit<\/th>\n                <th>Parameter<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <tr><td>1<\/td><td>Rated voltage<\/td><td>kV<\/td><td>7.2<\/td><\/tr>\n              <tr><td>2<\/td><td>Rated current<\/td><td>A<\/td><td>160, 250, 400, 630<\/td><\/tr>\n              <tr><td>3<\/td><td>Power-frequency withstand voltage (1 min)<\/td><td>kV<\/td><td>32<\/td><\/tr>\n              <tr><td>4<\/td><td>Lightning impulse withstand voltage<\/td><td>kV<\/td><td>60<\/td><\/tr>\n              <tr><td>5<\/td><td>Rated short-time withstand current<\/td><td>kA<\/td><td>10<\/td><\/tr>\n              <tr><td>6<\/td><td>Rated peak withstand current<\/td><td>kA<\/td><td>25<\/td><\/tr>\n              <tr><td>7<\/td><td>Overload withstand current<\/td><td>kA<\/td><td>15<\/td><\/tr>\n              <tr><td>8<\/td><td>Rated breaking capacity (AC-3 duty)<\/td><td>A<\/td><td>8&nbsp;\u00d7&nbsp;Ie, 25 operations<\/td><\/tr>\n              <tr><td>9<\/td><td>Rated making capacity (AC-3 duty)<\/td><td>A<\/td><td>10&nbsp;\u00d7&nbsp;Ie, 100 operations<\/td><\/tr>\n              <tr><td>10<\/td><td>Individual capacitor breaking current (F\u25a1\u25a1 only)<\/td><td>A<\/td><td>100 \/ 200 \/ 300<\/td><\/tr>\n              <tr><td>11<\/td><td>Back-to-back capacitor bank breaking current (F\u25a1\u25a1 only)<\/td><td>A<\/td><td>80 \/ 160 \/ 200<\/td><\/tr>\n              <tr><td>12<\/td><td>Rated contact gap<\/td><td>mm<\/td><td>4&nbsp;\u00b1&nbsp;0.5 (6&nbsp;\u00b1&nbsp;0.5 for F\u25a1\u25a1)<\/td><\/tr>\n              <tr><td>13<\/td><td>Overtravel<\/td><td>mm<\/td><td>\u2265&nbsp;1.5<\/td><\/tr>\n              <tr><td>14<\/td><td>Simultaneity of poles<\/td><td>ms<\/td><td>\u2264&nbsp;2<\/td><\/tr>\n              <tr><td>15<\/td><td>Electrical life (AC-3 duty)<\/td><td>Operations (&times;10<sup>4<\/sup>)<\/td><td>25<\/td><\/tr>\n              <tr><td>16<\/td><td>Electrical life (AC-4 duty)<\/td><td>Operations (&times;10<sup>4<\/sup>)<\/td><td>10<\/td><\/tr>\n              <tr><td>17<\/td><td>Mechanical life<\/td><td>Operations (&times;10<sup>4<\/sup>)<\/td><td>50<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n\n        <div class=\"dim-section\">\n          <p class=\"block-title\">Outline &amp; mounting dimensions \u2014 CKG3-\u25a1\/7.2 &amp; CKG3-\u25a1\/7.2F\u25a1\u25a1<\/p>\n          <p class=\"block-note\">\n            Typical outline and mounting dimensions for the standard CKG3-\u25a1\/7.2 indoor vacuum contactor and the\n            CKG3-\u25a1\/7.2F\u25a1\u25a1 back-to-back capacitor switching type. Use these drawings for cabinet layout and\n            busbar connection design, and verify all key dimensions against the latest XBRELE engineering documents.\n          <\/p>\n\n          <figure class=\"dim-main-fig\">\n            <img decoding=\"async\" id=\"ckg3-dim-img\"\n                 src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-dimensions-standard.webp\"\n                 alt=\"Outline and mounting dimensions of XBRELE CKG3 7.2 kV standard indoor vacuum contactor\">\n            <figcaption id=\"ckg3-dim-cap\">\n              Outline and mounting dimensions of CKG3-\u25a1\/7.2 standard indoor vacuum contactor. Suitable for\n              installation in metal-clad switchgear and control panels.\n            <\/figcaption>\n          <\/figure>\n\n          <div class=\"dim-thumb-row\">\n            <button class=\"dim-thumb-btn js-dim-thumb active\"\n                    type=\"button\"\n                    data-target-img=\"#ckg3-dim-img\"\n                    data-target-cap=\"#ckg3-dim-cap\"\n                    data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-dimensions-standard.webp\"\n                    data-alt=\"Outline and mounting dimensions of XBRELE CKG3 7.2 kV standard indoor vacuum contactor\"\n                    data-caption=\"Outline and mounting dimensions of CKG3-\u25a1\/7.2 standard indoor vacuum contactor. Use for cabinet layout and busbar design.\">\n              <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-dimensions-standard.webp\"\n                   alt=\"CKG3-\u25a1\/7.2 standard vacuum contactor dimension drawing thumbnail\">\n            <\/button>\n\n            <button class=\"dim-thumb-btn js-dim-thumb\"\n                    type=\"button\"\n                    data-target-img=\"#ckg3-dim-img\"\n                    data-target-cap=\"#ckg3-dim-cap\"\n                    data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-dimensions-capacitor-type.webp\"\n                    data-alt=\"Outline and mounting dimensions of XBRELE CKG3 7.2 kV back-to-back capacitor switching vacuum contactor\"\n                    data-caption=\"Outline and mounting dimensions of CKG3-\u25a1\/7.2F\u25a1\u25a1 capacitor switching vacuum contactor with solid insulated poles, used for capacitor bank cubicles.\">\n              <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg3-7_2kv-dimensions-capacitor-type.webp\"\n                   alt=\"CKG3-\u25a1\/7.2F\u25a1\u25a1 capacitor switching vacuum contactor dimension drawing thumbnail\">\n            <\/button>\n          <\/div>\n        <\/div>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">\n            Request a Quote for CKG3 Series\n          <\/a>\n        <\/div>\n\n      <\/div><\/div><div id=\"ckg4-12-std\" class=\"tab-content\">\n  <div class=\"panel-card\">\n    <div class=\"panel-grid\">\n      <div>\n        <figure class=\"main-fig-large\">\n          <img decoding=\"async\" id=\"ckg4-std-main-img\"\n               src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fd-vacuum-contactor-main.webp\"\n               alt=\"XBRELE CKG4-\u25a1\/12FD 12 kV high voltage vacuum contactor for standard feeder and capacitor switching\">\n          <figcaption id=\"ckg4-std-main-cap\">\n            CKG4-\u25a1\/12FD 12&nbsp;kV standard type vacuum contactor for feeder and capacitor switching in metal-clad\n            switchgear.\n          <\/figcaption>\n        <\/figure>\n\n        <div class=\"thumb-row\">\n          <button class=\"thumb-btn js-photo-thumb active\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-std-main-img\"\n                  data-target-cap=\"#ckg4-std-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fd-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12FD 12 kV high voltage vacuum contactor for standard feeder and capacitor switching\"\n                  data-caption=\"CKG4-\u25a1\/12FD standard 12&nbsp;kV vacuum contactor used in indoor switchgear for feeders and capacitor banks.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fd-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12FD 12 kV vacuum contactor thumbnail\">\n          <\/button>\n\n          <button class=\"thumb-btn js-photo-thumb\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-std-main-img\"\n                  data-target-cap=\"#ckg4-std-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fc-permanent-magnet-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12FC 12 kV permanent magnet high voltage vacuum contactor for reactive power compensation\"\n                  data-caption=\"CKG4-\u25a1\/12FC permanent magnet operated 12&nbsp;kV vacuum contactor, typically used in reactive power compensation and capacitor switching cubicles.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fc-permanent-magnet-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12FC 12 kV permanent magnet vacuum contactor thumbnail\">\n          <\/button>\n\n          <button class=\"thumb-btn js-photo-thumb\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-std-main-img\"\n                  data-target-cap=\"#ckg4-std-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12f-back-to-back-capacitor-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 12 kV back-to-back capacitor bank switching vacuum contactor\"\n                  data-caption=\"CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 back-to-back capacitor bank switching vacuum contactor, optimised for individual and back-to-back capacitor breaking duty.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12f-back-to-back-capacitor-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 back-to-back capacitor vacuum contactor thumbnail\">\n          <\/button>\n        <\/div>\n      <\/div>\n\n      <div class=\"panel-right\">\n        <h3>CKG4 12&nbsp;kV standard &amp; capacitor switching vacuum contactors<\/h3>\n        <p>\n          The CKG4 12&nbsp;kV family covers standard feeder duty, permanent magnet types and back-to-back\n          capacitor bank switching designs. All models are suitable for indoor metal-clad switchgear with\n          AC 50&nbsp;Hz systems, rated voltage 12&nbsp;kV and rated current up to 630&nbsp;A.\n        <\/p>\n        <p>\n          CKG4-\u25a1\/12FD is mainly used for motor and feeder switching. CKG4-\u25a1\/12FC adopts a permanent magnet\n          operating mechanism with fast speed and stable holding force. CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 is specially designed\n          for individual and back-to-back capacitor banks, with optimised contact structure and current-limiting\n          performance.\n        <\/p>\n        <div class=\"badge-row\">\n          <span class=\"badge\">12kV<\/span>\n          <span class=\"badge\">Indoor<\/span>\n          <span class=\"badge\">Up to 630A<\/span>\n          <span class=\"badge\">Capacitor banks<\/span>\n          <span class=\"badge\">Permanent magnet<\/span>\n        <\/div>\n        <p>\n          The combined data table below compares the main electrical ratings of CKG4-\u25a1\/12FD, CKG4-\u25a1\/12FC and\n          CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 so that engineers can quickly choose the right type for each feeder or capacitor bank.\n        <\/p>\n      <\/div>\n    <\/div><p class=\"block-title\">Main technical parameters \u2014 CKG4-\u25a1\/12FD \/ CKG4-\u25a1\/12FC \/ CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1<\/p>\n    <p class=\"block-note\">\n      Comparative ratings for standard feeder type, permanent magnet type and back-to-back capacitor switching type.\n      Values should be checked against the latest XBRELE datasheets before final design.\n    <\/p>\n    <div class=\"table-wrap\">\n  <table>\n    <thead>\n      <tr>\n        <th style=\"width:40px;\">No.<\/th>\n        <th>Item<\/th>\n        <th style=\"width:80px;\">Unit<\/th>\n        <th>CKG4-\u25a1\/12FD<\/th>\n        <th>CKG4-\u25a1\/12FC<\/th>\n        <th>CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td>1<\/td>\n        <td>Rated voltage<\/td>\n        <td>kV<\/td>\n        <td>12<\/td>\n        <td>12<\/td>\n        <td>12<\/td>\n      <\/tr>\n      <tr>\n        <td>2<\/td>\n        <td>Rated current<\/td>\n        <td>A<\/td>\n        <td>160 \/ 250 \/ 400 \/ 630<\/td>\n        <td>160 \/ 250 \/ 400 \/ 630<\/td>\n        <td>160 \/ 250 \/ 400 \/ 630<\/td>\n      <\/tr>\n      <tr>\n        <td>3<\/td>\n        <td>Power-frequency withstand voltage (1&nbsp;min)<\/td>\n        <td>kV<\/td>\n        <td>42<\/td>\n        <td>42<\/td>\n        <td>42<\/td>\n      <\/tr>\n      <tr>\n        <td>4<\/td>\n        <td>Lightning impulse withstand voltage<\/td>\n        <td>kV<\/td>\n        <td>75<\/td>\n        <td>75<\/td>\n        <td>75<\/td>\n      <\/tr>\n      <tr>\n        <td>5<\/td>\n        <td>Rated breaking current (AC-3 duty)<\/td>\n        <td>A<\/td>\n        <td>8Ie, 25&nbsp;operations<\/td>\n        <td>8Ie, 25&nbsp;operations<\/td>\n        <td>8Ie, 25&nbsp;operations<\/td>\n      <\/tr>\n      <tr>\n        <td>6<\/td>\n        <td>Rated making current (AC-3 duty)<\/td>\n        <td>A<\/td>\n        <td>10Ie, 100&nbsp;operations<\/td>\n        <td>10Ie, 100&nbsp;operations<\/td>\n        <td>10Ie, 100&nbsp;operations<\/td>\n      <\/tr>\n      <tr>\n        <td>7<\/td>\n        <td>Rated short-time withstand current<\/td>\n        <td>kA<\/td>\n        <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n        <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n        <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n      <\/tr>\n      <tr>\n        <td>8<\/td>\n        <td>Rated peak withstand current<\/td>\n        <td>kA<\/td>\n        <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n        <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n        <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n      <\/tr>\n      <tr>\n        <td>9<\/td>\n        <td>Overload withstand current<\/td>\n        <td>kA<\/td>\n        <td>&mdash;<\/td>\n        <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n        <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n      <\/tr>\n      <tr>\n        <td>10<\/td>\n        <td>Rated operating sequence<\/td>\n        <td>&mdash;<\/td>\n        <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n        <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n        <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n      <\/tr>\n      <tr>\n        <td>11<\/td>\n        <td>Individual capacitor breaking current<\/td>\n        <td>A<\/td>\n        <td>&mdash;<\/td>\n        <td>&mdash;<\/td>\n        <td>160&ndash;300<\/td>\n      <\/tr>\n      <tr>\n        <td>12<\/td>\n        <td>Back-to-back capacitor bank breaking current<\/td>\n        <td>A<\/td>\n        <td>&mdash;<\/td>\n        <td>&mdash;<\/td>\n        <td>80&ndash;200<\/td>\n      <\/tr>\n      <tr>\n        <td>13<\/td>\n        <td>Rated contact gap<\/td>\n        <td>mm<\/td>\n        <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n        <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n        <td>6&nbsp;&plusmn;&nbsp;0.5 (7&nbsp;&plusmn;&nbsp;0.5)<\/td>\n      <\/tr>\n      <tr>\n        <td>14<\/td>\n        <td>Overtravel<\/td>\n        <td>mm<\/td>\n        <td>&ge;&nbsp;1.5<\/td>\n        <td>&ge;&nbsp;1.5<\/td>\n        <td>&ge;&nbsp;1.5<\/td>\n      <\/tr>\n      <tr>\n        <td>15<\/td>\n        <td>Closing time (Electrically held)<\/td>\n        <td>ms<\/td>\n        <td>&mdash;<\/td>\n        <td>&mdash;<\/td>\n        <td>&le;&nbsp;110<\/td>\n      <\/tr>\n      <tr>\n        <td>16<\/td>\n        <td>Opening time (Magnetically latched)<\/td>\n        <td>ms<\/td>\n        <td>&mdash;<\/td>\n        <td>&le;&nbsp;90<\/td>\n        <td>&le;&nbsp;90<\/td>\n      <\/tr>\n      <tr>\n        <td>17<\/td>\n        <td>Closing time (Magnetically latched)<\/td>\n        <td>ms<\/td>\n        <td>&mdash;<\/td>\n        <td>&le;&nbsp;60<\/td>\n        <td>&le;&nbsp;60<\/td>\n      <\/tr>\n      <tr>\n        <td>18<\/td>\n        <td>Opening time (Quick-break mech.)<\/td>\n        <td>ms<\/td>\n        <td>&mdash;<\/td>\n        <td>&mdash;<\/td>\n        <td>&le;&nbsp;15<\/td>\n      <\/tr>\n      <tr>\n        <td>19<\/td>\n        <td>Contact bounce duration<\/td>\n        <td>ms<\/td>\n        <td>&le;&nbsp;2<\/td>\n        <td>&le;&nbsp;2<\/td>\n        <td>&le;&nbsp;2<\/td>\n      <\/tr>\n      <tr>\n        <td>20<\/td>\n        <td>Simultaneity of poles<\/td>\n        <td>ms<\/td>\n        <td>&le;&nbsp;2<\/td>\n        <td>&le;&nbsp;2<\/td>\n        <td>&le;&nbsp;2<\/td>\n      <\/tr>\n      <tr>\n        <td>21<\/td>\n        <td>Main circuit resistance<\/td>\n        <td>&micro;&Omega;<\/td>\n        <td>&le;&nbsp;80<\/td>\n        <td>&le;&nbsp;80<\/td>\n        <td>&le;&nbsp;80<\/td>\n      <\/tr>\n      <tr>\n        <td>22<\/td>\n        <td>Operating frequency at rated current<\/td>\n        <td>ops\/h<\/td>\n        <td>300<\/td>\n        <td>300<\/td>\n        <td>300 (Elec. held) \/ 120 (Mag. latched)<\/td>\n      <\/tr>\n      <tr>\n        <td>23<\/td>\n        <td>Mechanical life<\/td>\n        <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n        <td>50<\/td>\n        <td>50<\/td>\n        <td>50<\/td>\n      <\/tr>\n      <tr>\n        <td>24<\/td>\n        <td>Electrical life (AC-3 duty)<\/td>\n        <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n        <td>25<\/td>\n        <td>25<\/td>\n        <td>25<\/td>\n      <\/tr>\n      <tr>\n        <td>25<\/td>\n        <td>Electrical life (AC-4 duty)<\/td>\n        <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n        <td>&mdash;<\/td>\n        <td>10<\/td>\n        <td>10<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n\n    <div class=\"dim-section\">\n      <p class=\"block-title\">Outline &amp; mounting dimensions \u2014 CKG4-\u25a1\/12FD \/ 12FC \/ 12F\u25a1B\u25a1\u25a1<\/p>\n      <p class=\"block-note\">\n        Representative outline and mounting dimensions for the standard, permanent magnet and back-to-back capacitor\n        types. Use these drawings for panel layout and busbar design, and confirm key dimensions against the latest\n        XBRELE engineering data.\n      <\/p>\n\n      <figure class=\"dim-main-fig\">\n        <img decoding=\"async\" id=\"ckg4-std-dim-img\"\n             src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fd-dimensions.webp\"\n             alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12FD 12 kV vacuum contactor\">\n        <figcaption id=\"ckg4-std-dim-cap\">\n          Outline and mounting dimensions of CKG4-\u25a1\/12FD standard 12&nbsp;kV vacuum contactor for indoor switchgear.\n        <\/figcaption>\n      <\/figure>\n\n      <div class=\"dim-thumb-row\">\n        <button class=\"dim-thumb-btn js-dim-thumb active\"\n                type=\"button\"\n                data-target-img=\"#ckg4-std-dim-img\"\n                data-target-cap=\"#ckg4-std-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fd-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12FD 12 kV vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12FD 12&nbsp;kV vacuum contactor, suitable for feeder and capacitor cubicles.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fd-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12FD vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-std-dim-img\"\n                data-target-cap=\"#ckg4-std-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fc-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12FC 12 kV permanent magnet vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12FC permanent magnet 12&nbsp;kV vacuum contactor used for power factor correction banks.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12fc-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12FC permanent magnet vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-std-dim-img\"\n                data-target-cap=\"#ckg4-std-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12f-back-to-back-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 12 kV back-to-back capacitor bank vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 back-to-back capacitor bank vacuum contactor with permanent magnet mechanism.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12f-back-to-back-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12F\u25a1B\u25a1\u25a1 back-to-back capacitor vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n      <\/div>\n    <\/div>\n\n    <div class=\"cta-right-col\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Request a Quote for CKG4 12kV Standard &amp; Capacitor Types\n      <\/a>\n    <\/div>\n  <\/div><\/div><div id=\"ckg4-12-special\" class=\"tab-content\">\n  <div class=\"panel-card\">\n    <div class=\"panel-grid\">\n      <div>\n        <figure class=\"main-fig-large\">\n          <img decoding=\"async\" id=\"ckg4-special-main-img\"\n               src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12tl-zero-bounce-vacuum-contactor-main.webp\"\n               alt=\"XBRELE CKG4-\u25a1\/12TL 12 kV zero-bounce high voltage vacuum contactor with two-end inlet and outlet wiring\">\n          <figcaption id=\"ckg4-special-main-cap\">\n            CKG4-\u25a1\/12TL zero-bounce 12&nbsp;kV vacuum contactor with two-end inlet and outlet wiring, designed to\n            reduce contact bouncing and improve switching reliability.\n          <\/figcaption>\n        <\/figure>\n\n        <div class=\"thumb-row\">\n          <button class=\"thumb-btn js-photo-thumb active\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-special-main-img\"\n                  data-target-cap=\"#ckg4-special-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12tl-zero-bounce-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12TL 12 kV zero-bounce high voltage vacuum contactor with two-end inlet and outlet wiring\"\n                  data-caption=\"CKG4-\u25a1\/12TL zero-bounce 12&nbsp;kV vacuum contactor, used in indoor switchgear where reduced contact bounce and fast operation are required.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12tl-zero-bounce-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12TL zero-bounce vacuum contactor thumbnail\">\n          <\/button>\n\n          <button class=\"thumb-btn js-photo-thumb\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-special-main-img\"\n                  data-target-cap=\"#ckg4-special-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12x-phase-controlled-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12X\u25a1\u25a1 12 kV phase controlled high voltage vacuum contactor\"\n                  data-caption=\"CKG4-\u25a1\/12X\u25a1\u25a1 phase controlled 12&nbsp;kV vacuum contactor for three-phase circuits, suitable for on-demand switching and phase-separation control.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12x-phase-controlled-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12X\u25a1\u25a1 phase controlled vacuum contactor thumbnail\">\n          <\/button>\n\n          <button class=\"thumb-btn js-photo-thumb\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-special-main-img\"\n                  data-target-cap=\"#ckg4-special-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12xf-enclosed-phase-controlled-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12XF\u25a1 enclosed 12 kV phase controlled high voltage vacuum contactor\"\n                  data-caption=\"CKG4-\u25a1\/12XF\u25a1 enclosed phase controlled 12&nbsp;kV vacuum contactor with pole mounted operating mechanisms for each phase.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12xf-enclosed-phase-controlled-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12XF\u25a1 enclosed phase controlled vacuum contactor thumbnail\">\n          <\/button>\n\n          <button class=\"thumb-btn js-photo-thumb\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-special-main-img\"\n                  data-target-cap=\"#ckg4-special-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12-2-two-pole-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-\u25a1\/12-2 12 kV two-pole high voltage vacuum contactor\"\n                  data-caption=\"CKG4-\u25a1\/12-2 two-pole 12&nbsp;kV vacuum contactor widely used in two-phase power systems with rated current up to 630&nbsp;A.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12-2-two-pole-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-\u25a1\/12-2 two-pole vacuum contactor thumbnail\">\n          <\/button>\n        <\/div>\n      <\/div>\n\n      <div class=\"panel-right\">\n        <h3>CKG4 12&nbsp;kV special &amp; phase-controlled vacuum contactors<\/h3>\n        <p>\n          This group of CKG4 12&nbsp;kV contactors covers special versions such as zero-bounce TL type, phase\n          controlled 12X\u25a1\u25a1 and enclosed 12XF\u25a1 types, as well as the 12-2 two-pole configuration. All models are\n          designed for AC 50&nbsp;Hz systems with rated voltage 12&nbsp;kV and rated current up to 630&nbsp;A.\n        <\/p>\n        <p>\n          CKG4-\u25a1\/12TL focuses on reducing contact bounce and improving reliability. CKG4-\u25a1\/12X\u25a1\u25a1 and CKG4-\u25a1\/12XF\u25a1\n          use phase controlled operating mechanisms to achieve flexible on-demand switching. CKG4-\u25a1\/12-2 is an\n          extreme two-pole design for two-phase applications where compact layout and high breaking capacity are\n          required.\n        <\/p>\n        <div class=\"badge-row\">\n          <span class=\"badge\">12kV<\/span>\n          <span class=\"badge\">Special types<\/span>\n          <span class=\"badge\">Up to 630A<\/span>\n          <span class=\"badge\">Phase control<\/span>\n          <span class=\"badge\">Zero-bounce option<\/span>\n        <\/div>\n        <p>\n          The combined table below compares the main technical parameters of CKG4-\u25a1\/12TL, CKG4-\u25a1\/12X\u25a1\u25a1,\n          CKG4-\u25a1\/12XF\u25a1 and CKG4-\u25a1\/12-2, helping engineers select the correct special type for each project.\n        <\/p>\n      <\/div>\n    <\/div><p class=\"block-title\">Main technical parameters \u2014 CKG4-\u25a1\/12TL \/ 12X\u25a1\u25a1 \/ 12XF\u25a1 \/ 12-2<\/p>\n    <p class=\"block-note\">\n      Comparative ratings for zero-bounce, phase controlled, enclosed phase controlled and two-pole types.\n      Values are taken from the original XBRELE datasheets and should be checked again during final design.\n    <\/p>\n\n    <div class=\"table-wrap\">\n      <table>\n        <thead>\n          <tr>\n            <th style=\"width:40px;\">No.<\/th>\n            <th>Item<\/th>\n            <th style=\"width:80px;\">Unit<\/th>\n            <th>CKG4-\u25a1\/12TL<\/th>\n            <th>CKG4-\u25a1\/12X\u25a1\u25a1<\/th>\n            <th>CKG4-\u25a1\/12XF\u25a1<\/th>\n            <th>CKG4-\u25a1\/12-2<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>1<\/td>\n            <td>Rated voltage<\/td>\n            <td>kV<\/td>\n            <td>12<\/td>\n            <td>12<\/td>\n            <td>12<\/td>\n            <td>12<\/td>\n          <\/tr>\n          <tr>\n            <td>2<\/td>\n            <td>Rated current<\/td>\n            <td>A<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n          <\/tr>\n          <tr>\n            <td>3<\/td>\n            <td>Power-frequency withstand voltage (1&nbsp;min)<\/td>\n            <td>kV<\/td>\n            <td>42<\/td>\n            <td>42<\/td>\n            <td>42<\/td>\n            <td>42<\/td>\n          <\/tr>\n          <tr>\n            <td>4<\/td>\n            <td>Lightning impulse withstand voltage<\/td>\n            <td>kV<\/td>\n            <td>75<\/td>\n            <td>75<\/td>\n            <td>75<\/td>\n            <td>75<\/td>\n          <\/tr>\n          <tr>\n            <td>5<\/td>\n            <td>Rated breaking current (AC-3 duty)<\/td>\n            <td>A<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n          <\/tr>\n          <tr>\n            <td>6<\/td>\n            <td>Rated making current (AC-3 duty)<\/td>\n            <td>A<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n          <\/tr>\n          <tr>\n            <td>7<\/td>\n            <td>Rated short-time withstand current<\/td>\n            <td>kA<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n          <\/tr>\n          <tr>\n            <td>8<\/td>\n            <td>Rated peak withstand current<\/td>\n            <td>kA<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n          <\/tr>\n          <tr>\n            <td>9<\/td>\n            <td>Overload withstand current<\/td>\n            <td>kA<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n          <\/tr>\n          <tr>\n            <td>10<\/td>\n            <td>Rated operating sequence<\/td>\n            <td>&mdash;<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n          <\/tr>\n          <tr>\n            <td>11<\/td>\n            <td>Rated contact gap<\/td>\n            <td>mm<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n          <\/tr>\n          <tr>\n            <td>12<\/td>\n            <td>Overtravel<\/td>\n            <td>mm<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n          <\/tr>\n          <tr>\n            <td>13<\/td>\n            <td>Simultaneity of poles<\/td>\n            <td>ms<\/td>\n            <td>&le;&nbsp;2<\/td>\n            <td>&le;&nbsp;3 (Phase control)<\/td>\n            <td>&le;&nbsp;3 (Phase control)<\/td>\n            <td>&le;&nbsp;2<\/td>\n          <\/tr>\n          <tr>\n            <td>14<\/td>\n            <td>Mechanical life<\/td>\n            <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n            <td>50<\/td>\n            <td>50<\/td>\n            <td>50<\/td>\n            <td>50<\/td>\n          <\/tr>\n          <tr>\n            <td>15<\/td>\n            <td>Electrical life (AC-3 duty)<\/td>\n            <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n            <td>25<\/td>\n            <td>25<\/td>\n            <td>25<\/td>\n            <td>25<\/td>\n          <\/tr>\n          <tr>\n            <td>16<\/td>\n            <td>Electrical life (AC-4 duty)<\/td>\n            <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n            <td>10<\/td>\n            <td>10<\/td>\n            <td>10<\/td>\n            <td>10<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"dim-section\">\n      <p class=\"block-title\">Outline &amp; mounting dimensions \u2014 CKG4-\u25a1\/12TL \/ 12X\u25a1\u25a1 \/ 12XF\u25a1 \/ 12-2<\/p>\n      <p class=\"block-note\">\n        Representative outline and mounting dimensions for the zero-bounce, phase controlled, enclosed and two-pole\n        types. Use these drawings when designing switchgear panels and busbar arrangements.\n      <\/p>\n\n      <figure class=\"dim-main-fig\">\n        <img decoding=\"async\" id=\"ckg4-special-dim-img\"\n             src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12tl-dimensions.webp\"\n             alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12TL 12 kV zero-bounce vacuum contactor\">\n        <figcaption id=\"ckg4-special-dim-cap\">\n          Outline and mounting dimensions of CKG4-\u25a1\/12TL zero-bounce 12&nbsp;kV vacuum contactor with two-end inlet\n          and outlet wiring.\n        <\/figcaption>\n      <\/figure>\n\n      <div class=\"dim-thumb-row\">\n        <button class=\"dim-thumb-btn js-dim-thumb active\"\n                type=\"button\"\n                data-target-img=\"#ckg4-special-dim-img\"\n                data-target-cap=\"#ckg4-special-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12tl-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12TL 12 kV zero-bounce vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12TL zero-bounce 12&nbsp;kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12tl-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12TL zero-bounce vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-special-dim-img\"\n                data-target-cap=\"#ckg4-special-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12x-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12X\u25a1\u25a1 12 kV phase controlled vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12X\u25a1\u25a1 phase controlled 12&nbsp;kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12x-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12X\u25a1\u25a1 phase controlled vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-special-dim-img\"\n                data-target-cap=\"#ckg4-special-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12xf-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12XF\u25a1 enclosed 12 kV phase controlled vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12XF\u25a1 enclosed phase controlled 12&nbsp;kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12xf-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12XF\u25a1 enclosed phase controlled vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-special-dim-img\"\n                data-target-cap=\"#ckg4-special-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12-2-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12-2 12 kV two-pole vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12-2 two-pole 12&nbsp;kV vacuum contactor for two-phase power systems.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12-2-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12-2 two-pole vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n      <\/div>\n    <\/div>\n\n    <div class=\"cta-right-col\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Request a Quote for CKG4 12kV Special &amp; Phase-Controlled Types\n      <\/a>\n    <\/div>\n  <\/div><\/div><div id=\"ckg4-12-mech\" class=\"tab-content\">\n  <div class=\"panel-card\">\n    <div class=\"panel-grid\">\n      <div>\n        <figure class=\"main-fig-large\">\n          <img decoding=\"async\" id=\"ckg4-mech-main-img\"\n               src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-mechanical-interlock-vacuum-contactor-main.webp\"\n               alt=\"XBRELE CKG4-\u25a1\/12M mechanical interlocking 12 kV high voltage vacuum contactor assembly\">\n          <figcaption id=\"ckg4-mech-main-cap\">\n            CKG4-\u25a1\/12M series mechanical interlocking 12&nbsp;kV vacuum contactor assembly for forward and reverse\n            conversion or dual-feeder interlocking applications.\n          <\/figcaption>\n        <\/figure>\n      <\/div>\n\n      <div class=\"panel-right\">\n        <h3>CKG4 12&nbsp;kV mechanical interlocking vacuum contactors<\/h3>\n        <p>\n          The CKG4-\u25a1\/12M series is designed for mechanical interlocking between two or more 12&nbsp;kV vacuum\n          contactors. Typical applications include forward\/reverse conversion of high-voltage motors, dual-feeder\n          interlocking and safety interlocking between different circuits in metal-clad switchgear.\n        <\/p>\n        <p>\n          After adding the mechanical interlock device, the two contactors cannot be closed at the same time, which\n          greatly improves operation safety. The series keeps the same main electrical performance as the standard\n          CKG4 12&nbsp;kV vacuum contactors, with high reliability, long electrical and mechanical life and low\n          maintenance requirements.\n        <\/p>\n        <div class=\"badge-row\">\n          <span class=\"badge\">12kV<\/span>\n          <span class=\"badge\">Mechanical interlock<\/span>\n          <span class=\"badge\">Up to 630A<\/span>\n          <span class=\"badge\">Indoor<\/span>\n          <span class=\"badge\">Feeder \/ motor<\/span>\n        <\/div>\n        <p>\n          The combined table below compares the key ratings of CKG4-\u25a1\/12M-5, CKG4-\u25a1\/12M-4 and CKG4-\u25a1\/12M-3 so that\n          engineers can quickly select the appropriate interlocking configuration for each project.\n        <\/p>\n      <\/div>\n    <\/div><p class=\"block-title\">\n      Main technical parameters \u2014 CKG4-\u25a1\/12M-5 \/ CKG4-\u25a1\/12M-4 \/ CKG4-\u25a1\/12M-3\n    <\/p>\n    <p class=\"block-note\">\n      Mechanical interlocking type vacuum contactors, sharing the same electrical ratings. Values are referenced from\n      the XBRELE catalogue and should be checked against the latest datasheets for critical design work.\n    <\/p>\n\n    <div class=\"table-wrap\">\n      <table>\n        <thead>\n          <tr>\n            <th style=\"width:40px;\">No.<\/th>\n            <th>Item<\/th>\n            <th style=\"width:80px;\">Unit<\/th>\n            <th>CKG4-\u25a1\/12M-5<\/th>\n            <th>CKG4-\u25a1\/12M-4<\/th>\n            <th>CKG4-\u25a1\/12M-3<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>1<\/td>\n            <td>Rated voltage<\/td>\n            <td>kV<\/td>\n            <td>12<\/td>\n            <td>12<\/td>\n            <td>12<\/td>\n          <\/tr>\n          <tr>\n            <td>2<\/td>\n            <td>Rated current<\/td>\n            <td>A<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n            <td>160 \/ 250 \/ 400 \/ 630<\/td>\n          <\/tr>\n          <tr>\n            <td>3<\/td>\n            <td>Power-frequency withstand voltage (1&nbsp;min)<\/td>\n            <td>kV<\/td>\n            <td>42<\/td>\n            <td>42<\/td>\n            <td>42<\/td>\n          <\/tr>\n          <tr>\n            <td>4<\/td>\n            <td>Lightning impulse withstand voltage<\/td>\n            <td>kV<\/td>\n            <td>75<\/td>\n            <td>75<\/td>\n            <td>75<\/td>\n          <\/tr>\n          <tr>\n            <td>5<\/td>\n            <td>Rated breaking current (AC-3 duty)<\/td>\n            <td>A<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n            <td>8Ie, 25&nbsp;operations<\/td>\n          <\/tr>\n          <tr>\n            <td>6<\/td>\n            <td>Rated making current (AC-3 duty)<\/td>\n            <td>A<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n            <td>10Ie, 100&nbsp;operations<\/td>\n          <\/tr>\n          <tr>\n            <td>7<\/td>\n            <td>Rated short-time withstand current<\/td>\n            <td>kA<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n            <td>10Ie, 1.6 \/ 2.5 \/ 4 \/ 6.3<\/td>\n          <\/tr>\n          <tr>\n            <td>8<\/td>\n            <td>Rated peak withstand current<\/td>\n            <td>kA<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n            <td>25Ie, 4 \/ 6.3 \/ 10 \/ 16<\/td>\n          <\/tr>\n          <tr>\n            <td>9<\/td>\n            <td>Overload withstand current<\/td>\n            <td>kA<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n            <td>15Ie, 2.4 \/ 3.8 \/ 6 \/ 9.45<\/td>\n          <\/tr>\n          <tr>\n            <td>10<\/td>\n            <td>Rated operating sequence<\/td>\n            <td>&mdash;<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n            <td>0&ndash;180s&ndash;CO&ndash;180s&ndash;CO<\/td>\n          <\/tr>\n          <tr>\n            <td>11<\/td>\n            <td>Rated contact gap<\/td>\n            <td>mm<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n            <td>5.5&nbsp;&plusmn;&nbsp;0.5<\/td>\n          <\/tr>\n          <tr>\n            <td>12<\/td>\n            <td>Overtravel<\/td>\n            <td>mm<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n            <td>&ge;&nbsp;1.5<\/td>\n          <\/tr>\n          <tr>\n            <td>13<\/td>\n            <td>Simultaneity of poles<\/td>\n            <td>ms<\/td>\n            <td>&le;&nbsp;2<\/td>\n            <td>&le;&nbsp;2<\/td>\n            <td>&le;&nbsp;2<\/td>\n          <\/tr>\n          <tr>\n            <td>14<\/td>\n            <td>Mechanical life<\/td>\n            <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n            <td>50<\/td>\n            <td>50<\/td>\n            <td>50<\/td>\n          <\/tr>\n          <tr>\n            <td>15<\/td>\n            <td>Electrical life (AC-3 duty)<\/td>\n            <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n            <td>25<\/td>\n            <td>25<\/td>\n            <td>25<\/td>\n          <\/tr>\n          <tr>\n            <td>16<\/td>\n            <td>Electrical life (AC-4 duty)<\/td>\n            <td>Operations (&times;10<sup>4<\/sup>)<\/td>\n            <td>10<\/td>\n            <td>10<\/td>\n            <td>10<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"dim-section\">\n      <p class=\"block-title\">\n        Outline &amp; mounting dimensions \u2014 CKG4-\u25a1\/12M-5 \/ 12M-4 \/ 12M-3\n      <\/p>\n      <p class=\"block-note\">\n        Representative outline and mounting dimensions for three mechanical interlocking arrangements. Use these\n        drawings for panel layout, interlock mechanism mounting and busbar design, and confirm key dimensions with the\n        latest XBRELE engineering data.\n      <\/p>\n\n      <figure class=\"dim-main-fig\">\n        <img decoding=\"async\" id=\"ckg4-mech-dim-img\"\n             src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-5-dimensions.webp\"\n             alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12M-5 mechanical interlocking 12 kV vacuum contactor\">\n        <figcaption id=\"ckg4-mech-dim-cap\">\n          Outline and mounting dimensions of CKG4-\u25a1\/12M-5 mechanical interlocking 12&nbsp;kV vacuum contactor\n          assembly.\n        <\/figcaption>\n      <\/figure>\n\n      <div class=\"dim-thumb-row\">\n        <button class=\"dim-thumb-btn js-dim-thumb active\"\n                type=\"button\"\n                data-target-img=\"#ckg4-mech-dim-img\"\n                data-target-cap=\"#ckg4-mech-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-5-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12M-5 mechanical interlocking 12 kV vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12M-5 mechanical interlocking 12&nbsp;kV vacuum contactor assembly.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-5-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12M-5 mechanical interlocking vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-mech-dim-img\"\n                data-target-cap=\"#ckg4-mech-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-4-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12M-4 mechanical interlocking 12 kV vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12M-4 mechanical interlocking 12&nbsp;kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-4-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12M-4 mechanical interlocking vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-mech-dim-img\"\n                data-target-cap=\"#ckg4-mech-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-3-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-\u25a1\/12M-3 mechanical interlocking 12 kV vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-\u25a1\/12M-3 mechanical interlocking 12&nbsp;kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-12m-3-dimensions.webp\"\n               alt=\"CKG4-\u25a1\/12M-3 mechanical interlocking vacuum contactor dimension drawing thumbnail\">\n        <\/button>\n      <\/div>\n    <\/div>\n\n    <div class=\"cta-right-col\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Request a Quote for CKG4 12kV Mechanical Interlocking Types\n      <\/a>\n    <\/div>\n  <\/div><\/div><div id=\"ckg4-hi-current\" class=\"tab-content\">\n  <div class=\"panel-card\">\n    <div class=\"panel-grid\">\n      <div>\n        <figure class=\"main-fig-large\">\n          <img decoding=\"async\" id=\"ckg4-hi-main-img\"\n               src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-800-12-high-current-vacuum-contactor-main.webp\"\n               alt=\"XBRELE CKG4-800\/12 high current 12 kV vacuum contactor main image\">\n          <figcaption id=\"ckg4-hi-main-cap\">\n            CKG4-800\/12 high-current 12 kV vacuum contactor for feeders, motors and capacitor switching.\n          <\/figcaption>\n        <\/figure>\n\n        <div class=\"thumb-row\">\n          <button class=\"thumb-btn js-photo-thumb active\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-hi-main-img\"\n                  data-target-cap=\"#ckg4-hi-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-800-12-high-current-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-800\/12 12 kV high current vacuum contactor\"\n                  data-caption=\"CKG4-800\/12 high-current 12 kV vacuum contactor for heavy-duty feeder and motor circuits.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-800-12-high-current-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-800\/12 high current vacuum contactor thumbnail\">\n          <\/button>\n\n          <button class=\"thumb-btn js-photo-thumb\"\n                  type=\"button\"\n                  data-target-img=\"#ckg4-hi-main-img\"\n                  data-target-cap=\"#ckg4-hi-main-cap\"\n                  data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-1000-1250-12-high-current-vacuum-contactor-main.webp\"\n                  data-alt=\"XBRELE CKG4-1000\/12\u20131250\/12 12 kV high current vacuum contactor\"\n                  data-caption=\"CKG4-1000\/12 \u2013 1250\/12 high-current 12 kV vacuum contactor for large motors and capacitor banks.\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-1000-1250-12-high-current-vacuum-contactor-main.webp\"\n                 alt=\"CKG4-1000\u20131250\/12 high current vacuum contactor thumbnail\">\n          <\/button>\n        <\/div>\n      <\/div>\n\n      <div class=\"panel-right\">\n        <h3>CKG4 12 kV high-current vacuum contactors (800\u20131250 A)<\/h3>\n        <p>\n          The high-current CKG4 family (800 A to 1250 A) is designed for heavy-duty feeders, large motors and\n          capacitor bank circuits in 12 kV metal-clad switchgear. These models provide enhanced thermal performance,\n          stronger making\/breaking capacity and long-life contact systems.\n        <\/p>\n        <p>\n          Both CKG4-800\/12 and CKG4-1000\u20131250\/12 share the same key electrical ratings, while the physical structure\n          and heat-dissipation design differ to support higher continuous and short-time currents.\n        <\/p>\n        <div class=\"badge-row\">\n          <span class=\"badge\">12kV<\/span>\n          <span class=\"badge\">800\u20131250A<\/span>\n          <span class=\"badge\">Indoor<\/span>\n          <span class=\"badge\">Heavy-Duty<\/span>\n          <span class=\"badge\">Feeder \/ Motor \/ Capacitor<\/span>\n        <\/div>\n      <\/div>\n    <\/div><p class=\"block-title\">\n      Main technical parameters \u2014 CKG4-800\/12 &#038; CKG4-1000\u20131250\/12\n    <\/p>\n    <p class=\"block-note\">\n      Unified high-current ratings for both 800 A and 1000\u20131250 A versions. Confirm against latest XBRELE datasheets for final design.\n    <\/p>\n\n    <div class=\"table-wrap\">\n      <table>\n        <thead>\n          <tr>\n            <th style=\"width:40px;\">No.<\/th>\n            <th>Item<\/th>\n            <th style=\"width:80px;\">Unit<\/th>\n            <th>CKG4-800\/12<\/th>\n            <th>CKG4-1000\u20131250\/12<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>1<\/td><td>Rated voltage<\/td><td>kV<\/td><td>12<\/td><td>12<\/td><\/tr>\n          <tr><td>2<\/td><td>Rated current<\/td><td>A<\/td><td>800<\/td><td>1000 \/ 1250<\/td><\/tr>\n          <tr><td>3<\/td><td>Power-frequency withstand voltage (1 min)<\/td><td>kV<\/td><td>42<\/td><td>42<\/td><\/tr>\n          <tr><td>4<\/td><td>Lightning impulse withstand voltage<\/td><td>kV<\/td><td>75<\/td><td>75<\/td><\/tr>\n          <tr><td>5<\/td><td>Rated breaking current (AC-3 duty)<\/td><td>A<\/td><td>8Ie<\/td><td>8Ie<\/td><\/tr>\n          <tr><td>6<\/td><td>Rated making current (AC-3 duty)<\/td><td>A<\/td><td>10Ie<\/td><td>10Ie<\/td><\/tr>\n          <tr><td>7<\/td><td>Rated short-time withstand current<\/td><td>kA<\/td><td>25<\/td><td>31.5<\/td><\/tr>\n          <tr><td>8<\/td><td>Rated peak withstand current<\/td><td>kA<\/td><td>63<\/td><td>80<\/td><\/tr>\n          <tr><td>9<\/td><td>Main circuit resistance<\/td><td>\u00b5\u03a9<\/td><td>\u2264 60<\/td><td>\u2264 50<\/td><\/tr>\n          <tr><td>10<\/td><td>Mechanical life<\/td><td>Operations (&times;10<sup>4<\/sup>)<\/td><td>50<\/td><td>50<\/td><\/tr>\n          <tr><td>11<\/td><td>Electrical life (AC-3 duty)<\/td><td>Operations (&times;10<sup>4<\/sup>)<\/td><td>25<\/td><td>25<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n\n    <div class=\"dim-section\">\n      <p class=\"block-title\">\n        Outline &#038; mounting dimensions \u2014 CKG4-800\/12 &#038; CKG4-1000\u20131250\/12\n      <\/p>\n      <p class=\"block-note\">\n        Representative outline drawings for both high-current structures. Use for panel layout, busbar design and thermal planning.\n      <\/p>\n\n      <figure class=\"dim-main-fig\">\n        <img decoding=\"async\" id=\"ckg4-hi-dim-img\"\n             src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-800-12-dimensions.webp\"\n             alt=\"Outline and mounting dimensions of XBRELE CKG4-800\/12 high current 12 kV vacuum contactor\">\n        <figcaption id=\"ckg4-hi-dim-cap\">\n          Outline and mounting dimensions of CKG4-800\/12 high-current 12 kV vacuum contactor.\n        <\/figcaption>\n      <\/figure>\n\n      <div class=\"dim-thumb-row\">\n        <button class=\"dim-thumb-btn js-dim-thumb active\"\n                type=\"button\"\n                data-target-img=\"#ckg4-hi-dim-img\"\n                data-target-cap=\"#ckg4-hi-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-800-12-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-800\/12 high current 12 kV vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-800\/12 high-current 12 kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-800-12-dimensions.webp\"\n               alt=\"CKG4-800\/12 dimension thumbnail\">\n        <\/button>\n\n        <button class=\"dim-thumb-btn js-dim-thumb\"\n                type=\"button\"\n                data-target-img=\"#ckg4-hi-dim-img\"\n                data-target-cap=\"#ckg4-hi-dim-cap\"\n                data-src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-1000-1250-12-dimensions.webp\"\n                data-alt=\"Outline and mounting dimensions of XBRELE CKG4-1000\u20131250\/12 high current 12 kV vacuum contactor\"\n                data-caption=\"Outline and mounting dimensions of CKG4-1000-1250\/12 high-current 12 kV vacuum contactor.\">\n          <img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/11\/xbrele-ckg4-1000-1250-12-dimensions.webp\"\n               alt=\"CKG4-1000\u20131250\/12 dimension thumbnail\">\n        <\/button>\n      <\/div>\n    <\/div>\n\n    <div class=\"cta-right-col\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Request a Quote for CKG4 12kV High-Current Types (800\u20131250A)\n      <\/a>\n    <\/div>\n  <\/div><\/div><\/div><script>\n    (function(){\n      const root = document.querySelector('#sec3-ckg-tech');\n      if(!root) return;\n\n      \/* TAB \u5207\u6362 *\/\n      const tabs = root.querySelectorAll('.tab-btn');\n      const panels = root.querySelectorAll('.tab-content');\n\n      tabs.forEach(tab => {\n        tab.addEventListener('click', () => {\n          const target = tab.getAttribute('data-tab');\n          if(!target) return;\n          tabs.forEach(t => t.classList.remove('active'));\n          panels.forEach(p => p.classList.remove('active'));\n          tab.classList.add('active');\n          const panel = root.querySelector('#'+target);\n          if(panel) panel.classList.add('active');\n        });\n      });\n\n      \/* \u4e3b\u56fe gallery \u5207\u6362\uff08\u72ec\u7acb\uff09 *\/\n      const photoThumbs = root.querySelectorAll('.js-photo-thumb');\n      photoThumbs.forEach(btn => {\n        btn.addEventListener('click', () => {\n          const targetImg = root.querySelector(btn.dataset.targetImg);\n          const targetCap = root.querySelector(btn.dataset.targetCap);\n\n          if(targetImg && btn.dataset.src){\n            targetImg.src = btn.dataset.src;\n          }\n          if(targetImg && btn.dataset.alt){\n            targetImg.alt = btn.dataset.alt;\n          }\n          if(targetCap && btn.dataset.caption){\n            targetCap.innerHTML = btn.dataset.caption;\n          }\n\n          const siblings = btn.parentElement.querySelectorAll('.js-photo-thumb');\n          siblings.forEach(b => b.classList.remove('active'));\n          btn.classList.add('active');\n        });\n      });\n\n      \/* Dimensions gallery \u5207\u6362\uff08\u72ec\u7acb\uff09 *\/\n      const dimThumbs = root.querySelectorAll('.js-dim-thumb');\n      dimThumbs.forEach(btn => {\n        btn.addEventListener('click', () => {\n          const targetImg = root.querySelector(btn.dataset.targetImg);\n          const targetCap = root.querySelector(btn.dataset.targetCap);\n\n          if(targetImg && btn.dataset.src){\n            targetImg.src = btn.dataset.src;\n          }\n          if(targetImg && btn.dataset.alt){\n            targetImg.alt = btn.dataset.alt;\n          }\n          if(targetCap && btn.dataset.caption){\n            targetCap.innerHTML = btn.dataset.caption;\n          }\n\n          const siblings = btn.parentElement.querySelectorAll('.js-dim-thumb');\n          siblings.forEach(b => b.classList.remove('active'));\n          btn.classList.add('active');\n        });\n      });\n    })();\n  <\/script>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-226276d\" data-block-id=\"226276d\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-226276d-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-f89da7d\" data-v=\"4\" data-block-id=\"f89da7d\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-f89da7d-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-f89da7d-inner-blocks\">\n<section id=\"sec4-ckg-features\" style=\"background:#ffffff;padding:90px 0 100px;\">\n  <style>\n    #sec4-ckg-features{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec4-ckg-features .features-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec4-ckg-features .sec-header{\n      max-width:820px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec4-ckg-features .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec4-ckg-features h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec4-ckg-features .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec4-ckg-features .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n    }\n    #sec4-ckg-features .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:22px 22px 24px;\n      box-shadow:0 14px 32px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n    #sec4-ckg-features .card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#0F172A;\n    }\n    #sec4-ckg-features .card .tag{\n      display:inline-flex;\n      align-items:center;\n      justify-content:flex-start;\n      padding:3px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      background:#0F172A;\n      color:#E5E7EB;\n      margin-bottom:12px;\n    }\n    #sec4-ckg-features .card p{\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n      margin:0 0 10px;\n    }\n    #sec4-ckg-features .card ul{\n      list-style:none;\n      padding:0;\n      margin:6px 0 0;\n      font-size:14px;\n      color:#374151;\n    }\n    #sec4-ckg-features .card li{\n      position:relative;\n      padding-left:16px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec4-ckg-features .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    @media(max-width:1000px){\n      #sec4-ckg-features .grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:690px){\n      #sec4-ckg-features .features-shell{padding:0 18px;}\n      #sec4-ckg-features .grid{\n        grid-template-columns:1fr;\n      }\n      #sec4-ckg-features h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"features-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Configuration &amp; options<\/div>\n      <h2>Configuration options for CKG medium voltage vacuum contactors<\/h2>\n      <p>\n        CKG vacuum contactors can be configured with different control coils, auxiliary contacts,\n        interlocks and high-current or capacitor-duty versions, so panel builders can match the\n        exact requirements of their medium voltage switchgear projects.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- Card 1 -->\n      <article class=\"card\">\n        <span class=\"tag\">Control<\/span>\n        <h3>Control coils &amp; operating options<\/h3>\n        <p>\n          CKG3-7.2 and CKG4-12 contactors support a wide range of control voltages and duty classes,\n          allowing you to standardize control schemes across different panels.\n        <\/p>\n        <ul>\n          <li>AC or DC closing and opening coils for different control systems<\/li>\n          <li>Common control voltages for utility and industrial panels (e.g. 110\/220V)<\/li>\n          <li>Continuous or intermittent duty coil options according to application<\/li>\n          <li>Coil terminals and wiring arrangements aligned with CKG series catalog<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2 -->\n      <article class=\"card\">\n        <span class=\"tag\">Interlocks<\/span>\n        <h3>Auxiliary contacts &amp; mechanical interlocks<\/h3>\n        <p>\n          Flexible auxiliary and interlocking options help implement safe interlocks and status\n          signalling in MV switchgear and motor control centers.\n        <\/p>\n        <ul>\n          <li>NO\/NC auxiliary contact blocks for open\/close indication and logic<\/li>\n          <li>Mechanical interlock schemes for bus-tie or changeover applications<\/li>\n          <li>Interface provisions for door interlocks and padlocking where required<\/li>\n          <li>Contact arrangements coordinated with protection and control relays<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3 -->\n      <article class=\"card\">\n        <span class=\"tag\">Heavy-duty<\/span>\n        <h3>High-current &amp; special CKG versions<\/h3>\n        <p>\n          Beyond standard ratings, CKG4 contactors offer high-current and special-purpose versions\n          for demanding feeders, motors and capacitor banks.\n        <\/p>\n        <ul>\n          <li>High-current CKG4 versions up to 800A, 1000A and 1250A in 12kV systems<\/li>\n          <li>Special CKG4-1600\/12 and CKG4-2000\/12 designs for heavy-duty applications<\/li>\n          <li>Capacitor-switching variants tailored to reactive power compensation duty<\/li>\n          <li>Options for mechanical interlocking and customized mounting interfaces<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-d3898b7\" data-block-id=\"d3898b7\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-d3898b7-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-2df3863\" data-v=\"4\" data-block-id=\"2df3863\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-2df3863-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-2df3863-inner-blocks\">\n<section id=\"sec5-ckg-quality\" style=\"background:#0B1220;padding:72px 0 78px;color:#E5E7EB;\">\n  <style>\n    #sec5-ckg-quality{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec5-ckg-quality .quality-shell{\n      max-width:1500px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec5-ckg-quality .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec5-ckg-quality .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec5-ckg-quality h2{\n      font-size:26px;\n      margin:0 0 8px;\n      color:#F9FAFB;\n    }\n    #sec5-ckg-quality .sec-header p{\n      margin:0;\n      font-size:14px;\n      color:#CBD5F5;\n      line-height:1.7;\n    }\n\n    #sec5-ckg-quality .grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.2fr) minmax(0,1.05fr);\n      gap:28px;\n      align-items:flex-start;\n    }\n\n    \/* Left: process steps *\/\n    #sec5-ckg-quality .process-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:radial-gradient(circle at top left,rgba(56,189,248,.14) 0,rgba(15,23,42,.98) 36%,#020617 100%);\n      padding:22px 22px 24px;\n      box-shadow:0 22px 52px rgba(15,23,42,.9);\n    }\n    #sec5-ckg-quality .process-card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#E5F0FF;\n    }\n    #sec5-ckg-quality .process-card p{\n      font-size:13.5px;\n      color:#CBD5F5;\n      line-height:1.75;\n      margin:0 0 14px;\n    }\n    #sec5-ckg-quality .step-list{\n      list-style:none;\n      margin:0;\n      padding:0;\n      display:flex;\n      flex-direction:column;\n      gap:10px;\n    }\n    #sec5-ckg-quality .step{\n      display:grid;\n      grid-template-columns:auto minmax(0,1fr);\n      gap:8px 12px;\n      align-items:flex-start;\n    }\n    #sec5-ckg-quality .step-badge{\n      width:24px;\n      height:24px;\n      border-radius:999px;\n      border:1px solid rgba(148,163,184,.7);\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      font-size:11px;\n      font-weight:600;\n      color:#E5E7EB;\n      background:rgba(15,23,42,.85);\n      flex-shrink:0;\n    }\n    #sec5-ckg-quality .step h4{\n      font-size:13.5px;\n      margin:1px 0 3px;\n      color:#F9FAFB;\n    }\n    #sec5-ckg-quality .step p{\n      font-size:12.5px;\n      margin:0;\n      color:#CBD5F5;\n      line-height:1.7;\n    }\n\n    \/* Right: compact QA block *\/\n    #sec5-ckg-quality .qa-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:rgba(15,23,42,.96);\n      padding:20px 20px 22px;\n      box-shadow:0 22px 52px rgba(15,23,42,.8);\n    }\n    #sec5-ckg-quality .qa-section{\n      & {}\n    }\n    #sec5-ckg-quality .qa-label{\n      font-size:11px;\n      letter-spacing:.14em;\n      text-transform:uppercase;\n      color:#93C5FD;\n      margin-bottom:3px;\n    }\n    #sec5-ckg-quality .qa-card h3{\n      font-size:15px;\n      margin:0 0 4px;\n      color:#E5F0FF;\n    }\n    #sec5-ckg-quality .qa-card p{\n      font-size:13px;\n      color:#CBD5F5;\n      margin:0 0 4px;\n      line-height:1.65;\n    }\n    #sec5-ckg-quality .qa-block{\n      margin-top:10px;\n      padding-top:10px;\n      border-top:1px solid rgba(148,163,184,.35);\n    }\n    #sec5-ckg-quality .qa-block:first-of-type{\n      margin-top:6px;\n      padding-top:0;\n      border-top:none;\n    }\n    #sec5-ckg-quality .qa-block h4{\n      font-size:13.5px;\n      margin:0 0 3px;\n      color:#E5F0FF;\n    }\n    #sec5-ckg-quality .qa-block ul{\n      list-style:none;\n      padding:0;\n      margin:0;\n      font-size:12.5px;\n      color:#E5E7EB;\n    }\n    #sec5-ckg-quality .qa-block li{\n      position:relative;\n      padding-left:12px;\n      margin-bottom:2px;\n      line-height:1.6;\n    }\n    #sec5-ckg-quality .qa-block li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:7px;\n      width:5px;\n      height:5px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n    #sec5-ckg-quality .qa-note{\n      font-size:12px;\n      color:#9CA3AF;\n      margin-top:4px;\n    }\n\n    @media(max-width:1000px){\n      #sec5-ckg-quality .grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec5-ckg-quality .quality-shell{padding:0 18px;}\n      #sec5-ckg-quality h2{font-size:22px;}\n    }\n  <\/style>\n\n  <div class=\"quality-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Manufacturing &amp; quality control<\/div>\n      <h2>How XBRELE builds reliable CKG medium voltage vacuum contactors<\/h2>\n      <p>\n        Behind every CKG vacuum contactor there is a controlled manufacturing flow \u2013 from vacuum interrupter\n        and magnetic system assembly to routine testing \u2013 designed to ensure long-term reliability in\n        medium voltage switchgear panels.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- LEFT: process flow -->\n      <article class=\"process-card\">\n        <h3>From interrupter assembly to finished contactor<\/h3>\n        <p>\n          XBRELE manufactures the vacuum interrupter assemblies, magnetic circuits, operating mechanisms\n          and main circuits in a coordinated process. Each step is monitored and recorded for traceability\n          of every CKG3-7.2 and CKG4-12 vacuum contactor.\n        <\/p>\n\n        <ul class=\"step-list\">\n          <li class=\"step\">\n            <div class=\"step-badge\">01<\/div>\n            <div>\n              <h4>Vacuum interrupter &amp; contact system<\/h4>\n              <p>\n                Vacuum interrupters are checked for contact stroke, over-travel and resistance, then built\n                into insulated supports together with fixed and moving contacts for the main circuit.\n              <\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">02<\/div>\n            <div>\n              <h4>Coil &amp; magnetic circuit assembly<\/h4>\n              <p>\n                Closing and opening coils, yokes and armatures are assembled and adjusted so that magnetic\n                forces, pick-up voltage and drop-out characteristics meet CKG design requirements.\n              <\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">03<\/div>\n            <div>\n              <h4>Mechanism integration &amp; adjustment<\/h4>\n              <p>\n                The operating mechanism is assembled, lubricated and tuned so that opening and closing\n                speeds, bounce time and synchronism satisfy the specified limits for frequent switching duty.\n              <\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">04<\/div>\n            <div>\n              <h4>Panel interface &amp; terminal connection<\/h4>\n              <p>\n                Main terminals, auxiliary contacts, mechanical interlocks and mounting parts are configured\n                according to the required CKG contactor scheme for OEM panels or retrofit projects.\n              <\/p>\n            <\/div>\n          <\/li>\n          <li class=\"step\">\n            <div class=\"step-badge\">05<\/div>\n            <div>\n              <h4>Routine testing &amp; final inspection<\/h4>\n              <p>\n                Each assembled contactor passes electrical, dielectric and mechanical tests before packing,\n                with results linked to the serial number for future traceability.\n              <\/p>\n            <\/div>\n          <\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- RIGHT: compact QA -->\n      <section class=\"qa-card\">\n        <div class=\"qa-section\">\n          <div class=\"qa-label\">Electrical &amp; dielectric tests<\/div>\n          <h3>Routine tests for every CKG contactor<\/h3>\n          <p>\n            Electrical routine tests verify insulation level and switching performance under specified\n            operating conditions.\n          <\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Insulation &amp; main-circuit verification<\/h4>\n          <ul>\n            <li>Power-frequency withstand between phases and to earth<\/li>\n            <li>Insulation and functional checks on control and auxiliary circuits<\/li>\n            <li>Contact resistance check for each main circuit pole<\/li>\n            <li>Making \/ breaking verification on sample basis according to duty class<\/li>\n          <\/ul>\n          <p class=\"qa-note\">Routine-test records can be supplied with the shipment if required.<\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Mechanical reliability<\/h4>\n          <ul>\n            <li>Type-test verification of mechanical endurance for CKG series<\/li>\n            <li>Check of opening \/ closing speeds within specified limits<\/li>\n            <li>Control of contact bounce time and pole synchronism<\/li>\n            <li>Environmental checks for lubrication and low-temperature operation<\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Documentation &amp; traceability<\/h4>\n          <ul>\n            <li>Type-test reports and routine-test certificates on request<\/li>\n            <li>Factory inspection records with serial number traceability<\/li>\n            <li>Outline drawings &amp; wiring diagrams in editable format<\/li>\n            <li>Recommended maintenance guidelines for field technicians<\/li>\n          <\/ul>\n          <p class=\"qa-note\">\n            FAT \/ QAP \/ ITP witness testing can be arranged for utility, industrial or EPC projects.\n          <\/p>\n        <\/div>\n      <\/section>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-06177f4\" data-block-id=\"06177f4\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-06177f4-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-78cc55c\" data-v=\"4\" data-block-id=\"78cc55c\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-78cc55c-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-78cc55c-inner-blocks\">\n<section id=\"sec6-ckg-delivery\" style=\"background:#F9FAFB;padding:88px 0 96px;\">\n  <style>\n    #sec6-ckg-delivery{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec6-ckg-delivery .delivery-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec6-ckg-delivery .sec-header{\n      max-width:860px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec6-ckg-delivery .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec6-ckg-delivery h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec6-ckg-delivery .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec6-ckg-delivery .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n      align-items:stretch;\n    }\n    #sec6-ckg-delivery .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:20px 20px 22px;\n      box-shadow:0 16px 34px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n    #sec6-ckg-delivery .card-label{\n      font-size:11px;\n      letter-spacing:.14em;\n      text-transform:uppercase;\n      color:#6B7280;\n      margin-bottom:6px;\n    }\n    #sec6-ckg-delivery .card h3{\n      font-size:17px;\n      margin:0 0 8px;\n      color:#0F172A;\n    }\n    #sec6-ckg-delivery .card p{\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n      margin:0 0 10px;\n    }\n    #sec6-ckg-delivery .card ul{\n      list-style:none;\n      padding:0;\n      margin:4px 0 0;\n      font-size:13.5px;\n      color:#374151;\n    }\n    #sec6-ckg-delivery .card li{\n      position:relative;\n      padding-left:14px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec6-ckg-delivery .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:7px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    #sec6-ckg-delivery .cta-row{\n      margin-top:32px;\n      display:flex;\n      justify-content:center;\n    }\n    #sec6-ckg-delivery .cta-btn{\n      display:inline-block;\n      padding:11px 30px;\n      border-radius:8px;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:15px;\n      font-weight:600;\n      text-decoration:none;\n      letter-spacing:.03em;\n      box-shadow:0 12px 28px rgba(15,23,42,.2);\n      transition:all .25s ease;\n      white-space:nowrap;\n    }\n    #sec6-ckg-delivery .cta-btn:hover{\n      background:#1F2937;\n      box-shadow:0 16px 32px rgba(15,23,42,.28);\n      transform:translateY(-1px);\n    }\n\n    @media(max-width:1000px){\n      #sec6-ckg-delivery .grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:690px){\n      #sec6-ckg-delivery .delivery-shell{padding:0 18px;}\n      #sec6-ckg-delivery .grid{\n        grid-template-columns:1fr;\n      }\n      #sec6-ckg-delivery h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"delivery-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Delivery &amp; project support<\/div>\n      <h2>Lead time, packing and engineering support for CKG vacuum contactors<\/h2>\n      <p>\n        XBRELE supports OEM panel builders, industrial users and distributors with predictable delivery,\n        export-ready packing and engineering documentation for CKG3-7.2 and CKG4-12 medium voltage\n        vacuum contactors.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- Card 1: Lead time -->\n      <article class=\"card\">\n        <div class=\"card-label\">Lead time<\/div>\n        <h3>Standard &amp; project delivery<\/h3>\n        <p>\n          Typical delivery times for CKG vacuum contactors, depending on configuration and quantity.\n        <\/p>\n        <ul>\n          <li>Standard CKG3-7.2 \/ CKG4-12 contactors: about 15\u201325 days after order confirmation<\/li>\n          <li>Projects with mixed ratings, interlocks or special options: usually 25\u201335 days<\/li>\n          <li>Urgent orders can be discussed case-by-case according to production load<\/li>\n          <li>Sample units available on request for type checking and panel approvals<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2: Packing & logistics -->\n      <article class=\"card\">\n        <div class=\"card-label\">Export packing &amp; logistics<\/div>\n        <h3>Seaworthy packing &amp; flexible shipment<\/h3>\n        <p>\n          CKG vacuum contactors are packed for long-distance sea or land transportation with proper\n          protection for mechanisms and terminals.\n        <\/p>\n        <ul>\n          <li>Each contactor packed in export carton or wooden case with shock protection<\/li>\n          <li>Moisture-protection and anti-rust measures for metallic and moving parts<\/li>\n          <li>Suitable for mixed containers with other XBRELE switchgear and transformers<\/li>\n          <li>FOB Ningbo \/ Shanghai, CIF or other Incoterms can be supported according to the contract<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3: Project support -->\n      <article class=\"card\">\n        <div class=\"card-label\">Project support<\/div>\n        <h3>Documentation &amp; engineering assistance<\/h3>\n        <p>\n          XBRELE provides the documentation and technical support needed for MV panel design and\n          project approval involving CKG contactors.\n        <\/p>\n        <ul>\n          <li>Outline drawings, mounting details and wiring diagrams for CKG3 \/ CKG4<\/li>\n          <li>Type-test reports, routine-test certificates and factory inspection records<\/li>\n          <li>QAP \/ ITP preparation and FAT witness testing for utility, industrial and EPC projects<\/li>\n          <li>Support with selection of current ratings, duty class and control options for specific schemes<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n\n    <div class=\"cta-row\">\n      <a href=\"#ct-popup-882\" class=\"cta-btn\">\n        Discuss Your CKG Project with XBRELE\n      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-d6dbf7b\" data-block-id=\"d6dbf7b\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-d6dbf7b-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-d1eadd5\" data-v=\"4\" data-block-id=\"d1eadd5\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-d1eadd5-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-d1eadd5-inner-blocks\">\n<section id=\"sec7-ckg-faq\" style=\"padding:90px 0 110px;background:#ffffff;\">\n  <style>\n    #sec7-ckg-faq{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec7-ckg-faq .faq-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec7-ckg-faq .faq-header{\n      max-width:780px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec7-ckg-faq .faq-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec7-ckg-faq h2{\n      font-size:28px;\n      margin:0 0 12px;\n      color:#0F172A;\n    }\n    #sec7-ckg-faq .faq-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    #sec7-ckg-faq .faq-grid{\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:18px 26px;\n      align-items:flex-start;\n    }\n\n    #sec7-ckg-faq details{\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:14px 16px;\n      transition:box-shadow .2s ease, border-color .2s ease, background .2s ease;\n    }\n    #sec7-ckg-faq details[open]{\n      background:#FFFFFF;\n      border-color:#CBD5F5;\n      box-shadow:0 12px 30px rgba(15,23,42,.06);\n    }\n    #sec7-ckg-faq summary{\n      list-style:none;\n      cursor:pointer;\n      font-size:15px;\n      font-weight:600;\n      color:#111827;\n      display:flex;\n      align-items:flex-start;\n      justify-content:space-between;\n      gap:10px;\n    }\n    #sec7-ckg-faq summary::-webkit-details-marker{display:none;}\n    #sec7-ckg-faq .faq-icon{\n      flex-shrink:0;\n      width:18px;\n      height:18px;\n      border-radius:999px;\n      border:1px solid #D1D5DB;\n      display:flex;\n      align-items:center;\n      justify-content:center;\n      font-size:11px;\n      color:#6B7280;\n      margin-top:2px;\n    }\n    #sec7-ckg-faq details[open] .faq-icon{\n      background:#2563EB;\n      color:#FFFFFF;\n      border-color:#2563EB;\n    }\n    #sec7-ckg-faq .faq-answer{\n      margin-top:10px;\n      font-size:14px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n    #sec7-ckg-faq .faq-answer a{\n      color:#2563EB;\n      text-decoration:none;\n    }\n    #sec7-ckg-faq .faq-answer a:hover{\n      text-decoration:underline;\n    }\n\n    @media(max-width:1000px){\n      #sec7-ckg-faq .faq-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:690px){\n      #sec7-ckg-faq .faq-shell{padding:0 18px;}\n      #sec7-ckg-faq h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"faq-shell\">\n    <div class=\"faq-header\">\n      <div class=\"faq-kicker\">FAQ \u00b7 CKG Series<\/div>\n      <h2>Frequently asked questions about CKG medium voltage vacuum contactors<\/h2>\n      <p>\n        Below are typical questions from OEM panel builders, industrial users and distributors when selecting\n        XBRELE CKG3-7.2 and CKG4-12 medium voltage vacuum contactors for motor, feeder and capacitor switching.\n      <\/p>\n    <\/div>\n\n    <div class=\"faq-grid\">\n      <!-- Q1 -->\n      <details open>\n        <summary>\n          <span>What is the difference between CKG3-7.2 and CKG4-12 vacuum contactors?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          CKG3-7.2 is designed for 7.2&nbsp;kV systems with compact dimensions and current ratings typically up\n          to a few hundred amperes. CKG4-12 is a 12&nbsp;kV medium voltage vacuum contactor family with higher\n          insulation level and current ratings, including 400&nbsp;A, 630&nbsp;A, 800&nbsp;A, 1000&nbsp;A and\n          1250&nbsp;A versions. Both use vacuum interrupters and electromagnetic operating mechanisms, but the\n          CKG4-12 series covers a wider range of feeder and motor applications in 12&nbsp;kV switchgear panels.\n        <\/div>\n      <\/details>\n\n      <!-- Q2 -->\n      <details>\n        <summary>\n          <span>Which applications are CKG vacuum contactors suitable for?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          CKG medium voltage vacuum contactors are mainly used for frequent switching of AC motors, feeders,\n          transformers and capacitor banks in 7.2&nbsp;kV and 12&nbsp;kV systems. Typical applications include\n          motor control centers, mining switchgear, industrial plants, water treatment, cement and steel\n          facilities. For an overview of other vacuum contactor series at XBRELE, you can also visit the\n          <a href=\"https:\/\/xbrele.com\/vacuum-contactor\/\">Vacuum Contactor pillar page<\/a>.\n        <\/div>\n      <\/details>\n\n      <!-- Q3 -->\n      <details>\n        <summary>\n          <span>Can CKG vacuum contactors be used for capacitor switching duties?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Yes. XBRELE offers CKG capacitor-duty versions designed for reactive power compensation and power\n          factor correction systems. These variants use vacuum interrupters and damping arrangements suitable\n          for inrush currents and switching transients associated with capacitor banks. When enquiring, please\n          indicate that the duty is \u201ccapacitor switching\u201d so that the correct CKG version and rating can be\n          selected for your MV capacitor bank.\n        <\/div>\n      <\/details>\n\n      <!-- Q4 -->\n      <details>\n        <summary>\n          <span>What control voltages are available for CKG contactor coils?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          CKG vacuum contactors can be supplied with AC or DC closing and opening coils to match different\n          control systems. Common control voltages include 110&nbsp;V and 220&nbsp;V (AC or DC), while other\n          voltages can be reviewed on request. The pick-up and drop-out characteristics are tested to ensure\n          reliable operation within the tolerances specified in the technical data for CKG3-7.2 and CKG4-12.\n        <\/div>\n      <\/details>\n\n      <!-- Q5 -->\n      <details>\n        <summary>\n          <span>How are auxiliary contacts and mechanical interlocks configured?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          CKG contactors can be equipped with different NO\/NC auxiliary contact blocks for status indication\n          and interlocking logic. Mechanical interlocks can be provided for applications such as bus-tie,\n          changeover or transfer schemes. When sending an enquiry, please share your single-line diagram and\n          required interlocking scheme so that XBRELE can configure the auxiliary contacts and mechanical\n          interface correctly for your switchgear design.\n        <\/div>\n      <\/details>\n\n      <!-- Q6 -->\n      <details>\n        <summary>\n          <span>What routine tests are performed on CKG vacuum contactors before shipment?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Every CKG medium voltage vacuum contactor is 100% routine-tested at the factory. Typical tests\n          include power-frequency withstand between phases and to earth, insulation checks of control and\n          auxiliary circuits, measurement of contact resistance for each main circuit pole, mechanical\n          operating tests and functional checks of the operating mechanism. Routine-test records can be\n          provided together with the delivery if requested in the purchase order.\n        <\/div>\n      <\/details>\n\n      <!-- Q7 \u00b7 external dofollow link -->\n      <details>\n        <summary>\n          <span>Which international standards are referenced for CKG vacuum contactors?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          CKG medium voltage vacuum contactors are designed and type tested with reference to relevant IEC\n          standards for high-voltage and medium voltage contactors and switchgear, including IEC&nbsp;62271\n          series for high-voltage switchgear and controlgear. For more information about IEC&nbsp;62271-106\n          (High-voltage switchgear and controlgear \u2013 Part 106: AC contactors, contactor-based controllers and\n          motor starters), you can consult the official IEC webstore entry\n          <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/7038\" target=\"_blank\" rel=\"noopener\">\n            IEC 62271-106\n          <\/a>.\n        <\/div>\n      <\/details>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Vacuum Contactors \u00b7 Series CKG Vacuum Contactor Series XBRELE CKG vacuum contactor series is developed for medium voltage motor, transformer and capacitor bank applications. CKG3-7.2 and CKG4-12 contactors offer reliable vacuum interruption, compact construction and flexible control circuits, making them suitable for OEM switchgear panels and retrofit projects in 7.2&nbsp;kV and 12&nbsp;kV distribution networks. 7.2kV [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1186,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1199","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"bottom","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/comments?post=1199"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1199\/revisions"}],"predecessor-version":[{"id":1243,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1199\/revisions\/1243"}],"up":[{"embeddable":true,"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/pages\/1186"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/pt\/wp-json\/wp\/v2\/media?parent=1199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}