{"id":1304,"date":"2025-11-25T13:04:43","date_gmt":"2025-11-25T13:04:43","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1304"},"modified":"2025-11-25T16:56:33","modified_gmt":"2025-11-25T16:56:33","slug":"power-distribution-transformers","status":"publish","type":"page","link":"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/","title":{"rendered":"\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438"},"content":{"rendered":"\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-31bc2c8\" data-block-id=\"31bc2c8\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-31bc2c8-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-b28c9ef\" data-v=\"4\" data-block-id=\"b28c9ef\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-b28c9ef-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-b28c9ef-inner-blocks\">\n<section id=\"sec1-tr-hero\">\n  <style>\n    #sec1-tr-hero{\n      padding:200px 0 128px;\n      background:#0B1120;\n      color:#E5E7EB;\n    }\n\n    #sec1-tr-hero .tr-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      display:grid;\n      grid-template-columns:minmax(0,1.2fr) minmax(0,1fr);\n      gap:40px;\n      align-items:center;\n    }\n    @media(max-width:900px){\n      #sec1-tr-hero{\n        padding:140px 0 96px;\n      }\n      #sec1-tr-hero .tr-shell{\n        grid-template-columns:1fr;\n      }\n    }\n    @media(max-width:600px){\n      #sec1-tr-hero{\n        padding:110px 0 72px;\n      }\n    }\n\n    \/* \u6062\u590d\u539f\u7248\u5c0f\u5b57\u53f7\uff1a12px *\/\n    #sec1-tr-hero .tr-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:10px;\n    }\n    \n    \/* \u6062\u590d\u539f\u7248\u5c0f\u5b57\u53f7\uff1a32px (\u7cbe\u81f4\u611f\u6838\u5fc3) *\/\n    #sec1-tr-hero h1{\n      font-size:32px;\n      line-height:1.2;\n      margin:0 0 16px;\n      color:#F9FAFB;\n      font-weight: 700;\n    }\n\n    \/* \u6062\u590d\u539f\u7248\u5c0f\u5b57\u53f7\uff1a15px *\/\n    #sec1-tr-hero .tr-sub{\n      font-size:15px;\n      line-height:1.8;\n      color:#D1D5DB;\n      margin-bottom:24px;\n    }\n\n    \/* \u6062\u590d\u539f\u7248\u5c0f\u5b57\u53f7\uff1a13px *\/\n    #sec1-tr-hero .tr-meta{\n      font-size:13px;\n      color:#9CA3AF;\n      margin-bottom:24px;\n    }\n\n    #sec1-tr-hero .tr-cta-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:14px;\n      align-items:center;\n    }\n    \n    \/* \u6062\u590d\u539f\u7248\u6309\u94ae\u6837\u5f0f *\/\n    #sec1-tr-hero .btn-primary{\n      display:inline-flex;\n      align-items:center;\n      justify-content:center;\n      padding:0 26px;\n      height:44px;\n      border-radius:999px;\n      border:none;\n      background:#00B8B8;\n      color:#0B1120;\n      font-size:14px;\n      font-weight:600;\n      text-decoration:none;\n      cursor:pointer;\n      transition:background .2s ease, transform .2s ease, box-shadow .2s ease;\n      box-shadow:0 18px 40px rgba(0,184,184,.35);\n    }\n    #sec1-tr-hero .btn-primary:hover{\n      background:#06A4A4;\n      transform:translateY(-1px);\n      box-shadow:0 20px 48px rgba(0,184,184,.40);\n    }\n    #sec1-tr-hero .btn-ghost{\n      display:inline-flex;\n      align-items:center;\n      justify-content:center;\n      padding:0 22px;\n      height:44px;\n      border-radius:999px;\n      border:1px solid rgba(148,163,184,.6);\n      background:transparent;\n      color:#E5E7EB;\n      font-size:14px;\n      font-weight:500;\n      text-decoration:none;\n      cursor:pointer;\n      transition:background .2s ease, border-color .2s ease, color .2s ease;\n    }\n    #sec1-tr-hero .btn-ghost:hover{\n      background:rgba(15,23,42,.85);\n      border-color:#00B8B8;\n      color:#F9FAFB;\n    }\n\n    \/* \u53f3\u4fa7\u5a92\u4f53\u5361\u7247 *\/\n    #sec1-tr-hero .tr-hero-media{\n      position:relative;\n      min-height:220px;\n      border-radius:20px;\n      background:radial-gradient(circle at 70% 20%,#00B8B8 0,rgba(15,23,42,1) 55%, #020617 100%);\n      overflow:hidden;\n      padding:22px 22px 20px;\n    }\n\n    #sec1-tr-hero .tr-hero-label{\n      font-size:11px;\n      text-transform:uppercase;\n      letter-spacing:.14em;\n      color:#E5E7EB;\n      opacity:.9;\n      margin-bottom:4px;\n    }\n    #sec1-tr-hero .tr-hero-text{\n      font-size:13px;\n      color:#C4CFDE;\n      max-width:70%;\n      line-height:1.6;\n    }\n\n    #sec1-tr-hero .tr-hero-tag{\n      position:absolute;\n      top:18px;\n      right:18px;\n      padding:4px 12px;\n      border-radius:999px;\n      background:rgba(15,23,42,.8);\n      border:1px solid rgba(148,163,184,.6);\n      font-size:11px;\n      color:#E5E7EB;\n      white-space:nowrap;\n    }\n\n    #sec1-tr-hero .tr-hero-note{\n      position:absolute;\n      left:22px;\n      bottom:18px;\n      font-size:12px;\n      color:#9CA3AF;\n      max-width:76%;\n      line-height:1.7;\n    }\n  <\/style>\n\n  <div class=\"tr-shell\">\n    <div class=\"tr-copy\">\n      <div class=\"tr-kicker\">HV &#038; MV POWER SOLUTIONS<\/div>\n      \n      <h1>Power Distribution Transformers Manufacturer (10kV &#8211; 35kV)<\/h1>\n      \n      <p class=\"tr-sub\">\n        XBRELE is a specialized <strong>Power Distribution Transformers<\/strong> manufacturer delivering high-efficiency solutions for global grids. From <strong>hermetically sealed oil-immersed<\/strong> S13 units to fire-safe <strong>cast resin dry-type<\/strong> models, our step-down transformers are certified to IEC 60076 standards.\n      <\/p>\n      \n      <p class=\"tr-meta\">\n        As an OEM provider, we integrate automatic foil winding and vacuum drying technologies to ensure reliable operation in 10kV, 20kV, and 35kV networks.\n      <\/p>\n      \n      <div class=\"tr-cta-row\">\n        <a href=\"#sec3-tr-series\" class=\"btn-primary\">View Product Series<\/a>\n        <a href=\"\/contact\/\" class=\"btn-ghost\">Request a Quote<\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"tr-hero-media\">\n      <div class=\"tr-hero-label\">Portfolio Snapshot<\/div>\n      <div class=\"tr-hero-text\">\n        Complete range from 30kVA distribution units to 31,500kVA power transformers.\n      <\/div>\n\n      <div class=\"tr-hero-tag\">S13 \u00b7 SCB10 \u00b7 SBH15 \u00b7 35kV<\/div>\n\n      <div class=\"tr-hero-note\">\n        Core Tech: Automatic foil winding &#038; vacuum drying.\n        <br>Voltage: 6kV \/ 10kV \/ 20kV \/ 35kV.\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-13a9f3c\" data-block-id=\"13a9f3c\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-13a9f3c-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-d8a330a\" data-v=\"4\" data-block-id=\"d8a330a\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-d8a330a-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-d8a330a-inner-blocks\">\n<section id=\"sec2-tr-overview\" style=\"padding:80px 0; background:#F9FAFB;\">\n  <style>\n    #sec2-tr-overview .ov-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:40px;\n      align-items:center;\n      color:#0F172A;\n    }\n    @media(max-width:900px){\n      #sec2-tr-overview .ov-shell{\n        grid-template-columns:1fr;\n      }\n    }\n\n    #sec2-tr-overview .ov-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px; \/* Original small size *\/\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:6px;\n    }\n    #sec2-tr-overview h2{\n      font-size:28px; \/* Original small size *\/\n      margin:0 0 16px;\n      line-height: 1.35;\n    }\n    #sec2-tr-overview .ov-lead{\n      font-size:15px; \/* Original small size *\/\n      line-height:1.9;\n      margin-bottom:16px;\n      color:#4B5563;\n    }\n    #sec2-tr-overview .ov-body p{\n      font-size:15px; \/* Original small size *\/\n      line-height:1.9;\n      margin:0 0 10px;\n      color:#4B5563;\n    }\n\n    #sec2-tr-overview .ov-panel{\n      background:#FFFFFF;\n      border-radius:16px;\n      border:1px solid #E5E7EB;\n      padding:22px 22px 20px;\n      box-shadow:0 8px 20px rgba(15,23,42,.04);\n    }\n    #sec2-tr-overview .ov-panel h3{\n      margin:0 0 10px;\n      font-size:16px;\n    }\n    #sec2-tr-overview .ov-meta-list{\n      list-style:none;\n      padding:0;\n      margin:0;\n      font-size:14px;\n      color:#4B5563;\n    }\n    #sec2-tr-overview .ov-meta-list li{\n      display:flex;\n      justify-content:space-between;\n      padding:6px 0;\n      border-bottom:1px dashed #E5E7EB;\n    }\n    #sec2-tr-overview .ov-meta-list li span:first-child{\n      opacity:.7;\n    }\n  <\/style>\n\n  <div class=\"ov-shell\">\n    <div>\n      <div class=\"ov-kicker\">Manufacturing Capability<\/div>\n      <h2>Comprehensive Voltage Transformation: 6kV to 35kV<\/h2>\n      <p class=\"ov-lead\">\n        As a specialized <strong>Power Distribution Transformers<\/strong> manufacturer, XBRELE integrates advanced capabilities\u2014including fully automatic foil winding machines and vacuum drying systems\u2014to produce reliable medium voltage equipment consistent with IEC 60076 standards.\n      <\/p>\n      <div class=\"ov-body\">\n        <p>\n          Our portfolio covers the full spectrum of grid requirements: from robust <strong>10kV\/11kV distribution transformers<\/strong> for urban networks to heavy-duty <strong>35kV power transformers<\/strong> for industrial substations. We maintain precise control over core stacking and coil winding to ensure optimal electrical performance.\n        <\/p>\n        <p>\n          We offer two primary technologies: <strong>Oil-Immersed<\/strong> units with hermetically sealed corrugated tanks for outdoor durability, and <strong>Cast Resin Dry-Type<\/strong> units for indoor fire safety. Whether utilizing high-permeability silicon steel or advanced amorphous alloys, our focus is on reducing no-load losses and ensuring maintenance-free operation.\n        <\/p>\n      <\/div>\n    <\/div>\n\n    <aside class=\"ov-panel\">\n      <h3>Technical Scope<\/h3>\n      <ul class=\"ov-meta-list\">\n        <li><span>Rated Voltage<\/span><span>6kV \/ 10kV \/ 20kV \/ 35kV<\/span><\/li>\n        <li><span>Rated Capacity<\/span><span>30kVA \u2013 31,500kVA<\/span><\/li>\n        <li><span>Cooling Methods<\/span><span>ONAN \/ ONAF \/ AN \/ AF<\/span><\/li>\n        <li><span>Core Material<\/span><span>Silicon Steel \/ Amorphous Alloy<\/span><\/li>\n        <li><span>Standard<\/span><span>IEC 60076 \/ GB 1094<\/span><\/li>\n        <li><span>Key Markets<\/span><span>Grid, Mining, Petrochemical<\/span><\/li>\n      <\/ul>\n    <\/aside>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-d93ecc1\" data-block-id=\"d93ecc1\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-d93ecc1-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-8a35d87\" data-v=\"4\" data-block-id=\"8a35d87\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-8a35d87-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-8a35d87-inner-blocks\">\n<section id=\"sec3-tr-series\" style=\"padding:90px 0;background:#F9FAFB;\">\n  <style>\n    #sec3-tr-series .tr-section-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n\n    #sec3-tr-series .tr-header{\n      max-width:820px;\n      margin:0 auto 48px;\n      text-align:center;\n    }\n    #sec3-tr-series .tr-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px; \/* Original small size *\/\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:8px;\n    }\n    #sec3-tr-series .tr-header h2{\n      font-size:28px; \/* Original small size *\/\n      line-height:1.35;\n      margin:0 0 12px;\n      color:#111827;\n    }\n    #sec3-tr-series .tr-sub{\n      font-size:15px; \/* Original small size *\/\n      line-height:1.8;\n      color:#4B5563;\n      margin:0;\n    }\n\n    #sec3-tr-series .tr-row{\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      column-gap:56px;\n      row-gap:32px;\n      align-items:center;\n      background:#FFFFFF;\n      border-radius:24px;\n      box-shadow:0 18px 45px rgba(15,23,42,0.08);\n      padding:32px 30px 30px;\n      margin-bottom:28px;\n    }\n    #sec3-tr-series .tr-row.tr-row-alt{\n      grid-template-columns:minmax(0,1fr) minmax(0,1.3fr);\n    }\n    @media (max-width:1000px){\n      #sec3-tr-series .tr-row,\n      #sec3-tr-series .tr-row.tr-row-alt{\n        grid-template-columns:1fr;\n      }\n    }\n\n    #sec3-tr-series .tr-text-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px; \/* Original small size *\/\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:8px;\n    }\n    #sec3-tr-series .tr-row h3{\n      font-size:22px; \/* Original small size *\/\n      line-height:1.4;\n      margin:0 0 14px;\n      color:#111827;\n    }\n    #sec3-tr-series .tr-lead{\n      font-size:15px; \/* Original small size *\/\n      line-height:1.8;\n      color:#4B5563;\n      margin:0 0 16px;\n      max-width:660px;\n    }\n    #sec3-tr-series .tr-meta{\n      font-size:14px;\n      line-height:1.7;\n      color:#6B7280;\n      margin:0 0 18px;\n      max-width:660px;\n    }\n\n    #sec3-tr-series .tr-list-title{\n      font-size:13px;\n      font-weight:600;\n      text-transform:uppercase;\n      letter-spacing:.12em;\n      color:#9CA3AF;\n      margin-bottom:6px;\n    }\n    #sec3-tr-series .tr-list{\n      list-style:none;\n      padding:0;\n      margin:0;\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:6px 20px;\n      font-size:14px; \/* Original small size *\/\n      color:#4B5563;\n    }\n    @media (max-width:690px){\n      #sec3-tr-series .tr-list{\n        grid-template-columns:1fr;\n      }\n    }\n    #sec3-tr-series .tr-list li::before{\n      content:\"\";\n      display:inline-block;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#00B8B8;\n      margin-right:8px;\n      transform:translateY(-1px);\n    }\n\n    #sec3-tr-series .tr-link{\n      display:inline-flex;\n      align-items:center;\n      gap:6px;\n      margin-top:14px;\n      font-size:13px;\n      font-weight:600;\n      color:#00B8B8;\n      text-decoration:none;\n    }\n    #sec3-tr-series .tr-figure-wrap{\n      position:relative;\n    }\n    #sec3-tr-series .tr-figure{\n      border-radius:18px;\n      background:#FFFFFF;\n      box-shadow:0 10px 30px rgba(15,23,42,0.08);\n      padding:24px 22px 22px;\n    }\n    #sec3-tr-series .tr-figure img{\n      display:block;\n      width:100%;\n      height:auto;\n    }\n    #sec3-tr-series .tr-figure-caption{\n      margin-top:10px;\n      font-size:12px;\n      line-height:1.6;\n      color:#9CA3AF;\n    }\n    #sec3-tr-series .tr-chip{\n      position:absolute;\n      top:14px;\n      right:18px;\n      padding:4px 12px;\n      font-size:11px;\n      border-radius:999px;\n      background:rgba(15,23,42,.88);\n      color:#E5E7EB;\n      border:1px solid rgba(148,163,184,.6);\n      text-transform:uppercase;\n      letter-spacing:.12em;\n      white-space:nowrap;\n    }\n    @media (max-width:1000px){\n      #sec3-tr-series .tr-chip{\n        position:static;\n        display:inline-block;\n        margin-bottom:10px;\n      }\n      #sec3-tr-series .tr-figure-wrap{\n        padding-top:6px;\n      }\n    }\n  <\/style>\n\n  <div class=\"tr-section-shell\">\n\n    <div class=\"tr-header\">\n      <div class=\"tr-kicker\">Product Series<\/div>\n      <h2>Select Your Transformer Solution<\/h2>\n      <p class=\"tr-sub\">\n        XBRELE supplies three distinct transformer technologies tailored for specific environments: \n        <strong>Oil-Immersed<\/strong> for outdoor efficiency, <strong>Cast Resin Dry-Type<\/strong> for indoor safety, \n        and <strong>Amorphous Alloy<\/strong> for green energy projects.\n      <\/p>\n    <\/div>\n\n    <div class=\"tr-row\">\n      <div class=\"tr-text\">\n        <div class=\"tr-text-kicker\">OIL IMMERSED TRANSFORMER SERIES<\/div>\n        <h3>S11 \/ S13 &#038; 35kV Power Transformers: Hermetically Sealed<\/h3>\n        <p class=\"tr-lead\">\n          Our Oil-Immersed range includes the standard <strong>S11\/S13 distribution transformers<\/strong> (10kV-20kV) and the heavy-duty <strong>SZ-35kV power transformers<\/strong>. Featuring a corrugated tank structure that eliminates the oil conservator, they are fully hermetically sealed to prevent oxygen ingress and oil aging.\n        <\/p>\n        <p class=\"tr-meta\">\n          The S13 series utilizes a wound core design to reduce no-load losses by approximately 30% compared to S9 standards, making it ideal for rural and urban grids.\n        <\/p>\n        <div class=\"tr-list-title\">Key Specifications<\/div>\n        <ul class=\"tr-list\">\n          <li><strong>Models:<\/strong> S11-M, S13-M, SZ-35kV<\/li>\n          <li><strong>Capacity:<\/strong> 30kVA \u2013 31,500kVA<\/li>\n          <li><strong>Voltage:<\/strong> 6kV \/ 10kV \/ 20kV \/ 35kV<\/li>\n          <li><strong>Tech:<\/strong> Vacuum Oil Injection &#038; OLTC available<\/li>\n          <li><strong>Structure:<\/strong> Fully sealed corrugated tank<\/li>\n          <li><strong>Usage:<\/strong> Outdoor Substations, Mining, Petroleum<\/li>\n        <\/ul>\n        <a class=\"tr-link\" href=\"\/oil-immersed-transformer\/\">\n          View Oil-Immersed Series <span>\u2192<\/span>\n        <\/a>\n      <\/div>\n      <div class=\"tr-figure-wrap\">\n        <span class=\"tr-chip\">OUTDOOR \/ SEALED<\/span>\n        <div class=\"tr-figure\">\n          <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/XBRELE-S13-oil-immersed-transformer-line-art.webp\" alt=\"Line art drawing of XBRELE S13 series oil-immersed distribution transformer\">\n          <div class=\"tr-figure-caption\">\n            S13-M Series 10kV Oil-Immersed Distribution Transformer with corrugated cooling fins.\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"tr-row tr-row-alt\">\n      <div class=\"tr-figure-wrap\">\n        <span class=\"tr-chip\">INDOOR \/ FIRE SAFE<\/span>\n        <div class=\"tr-figure\">\n          <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/XBRELE-SCB13-cast-resin-transformer-line-art.webp\" alt=\"Technical line art illustration of XBRELE SCB cast resin dry-type transformer\">\n          <div class=\"tr-figure-caption\">\n            SCB Series Cast Resin Dry-Type Transformer with IP20 enclosure for indoor installation.\n          <\/div>\n        <\/div>\n      <\/div>\n      <div class=\"tr-text\">\n        <div class=\"tr-text-kicker\">DRY TYPE TRANSFORMER SERIES<\/div>\n        <h3>SCB Cast Resin &#038; 35kV Dry-Type Power Transformers<\/h3>\n        <p class=\"tr-lead\">\n          Designed for high fire-safety requirements, our Dry-Type series covers standard <strong>SCB10\/11\/12\/13<\/strong> (10kV-20kV), environmental <strong>SG(B)10<\/strong> (Class H), and the high-voltage <strong>SCB11-35kV<\/strong> power transformer.\n        <\/p>\n        <p class=\"tr-meta\">\n          Using epoxy resin vacuum casting (F-class) or DuPont Nomex (H-class), these units are moisture-proof, maintenance-free, and capable of operating at 100% humidity.\n        <\/p>\n        <div class=\"tr-list-title\">Key Specifications<\/div>\n        <ul class=\"tr-list\">\n          <li><strong>Models:<\/strong> SCB10-13, SG(B)10, SCB11-35kV<\/li>\n          <li><strong>Insulation:<\/strong> F-Class (Epoxy) \/ H-Class (Nomex)<\/li>\n          <li><strong>Safety:<\/strong> Fire-retardant, Self-extinguishing<\/li>\n          <li><strong>HV Option:<\/strong> Up to 35kV Dry-Type available<\/li>\n          <li><strong>Tech:<\/strong> Foil winding for short-circuit strength<\/li>\n          <li><strong>Usage:<\/strong> High-rise buildings, Subways, Airports<\/li>\n        <\/ul>\n        <a class=\"tr-link\" href=\"\/dry-type-transformer\/\">\n          View Dry-Type Series <span>\u2192<\/span>\n        <\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"tr-row\">\n      <div class=\"tr-text\">\n        <div class=\"tr-text-kicker\">ENERGY SAVING SERIES<\/div>\n        <h3>SBH15 Amorphous Alloy Transformers (Oil &#038; Dry)<\/h3>\n        <p class=\"tr-lead\">\n          For projects demanding maximum energy efficiency, the <strong>SBH15 (Oil)<\/strong> and <strong>SCBH15 (Dry)<\/strong> series utilize advanced amorphous alloy strip cores. This technology reduces no-load losses by approximately <strong>75%<\/strong> compared to silicon steel S9 models.\n        <\/p>\n        <p class=\"tr-meta\">\n          Ideal for reducing operating costs (OPEX) in government grids and green energy projects. The low-voltage side features copper foil winding for enhanced short-circuit resistance.\n        <\/p>\n        <div class=\"tr-list-title\">Key Specifications<\/div>\n        <ul class=\"tr-list\">\n          <li><strong>Models:<\/strong> SBH15-M (Oil), SCBH15 (Dry)<\/li>\n          <li><strong>Efficiency:<\/strong> 75% lower no-load loss<\/li>\n          <li><strong>Core:<\/strong> Amorphous alloy strip technology<\/li>\n          <li><strong>Winding:<\/strong> Copper foil low-voltage coil<\/li>\n          <li><strong>Group:<\/strong> Dyn11 connection to reduce harmonics<\/li>\n          <li><strong>Usage:<\/strong> Solar\/Wind farms, Rural distribution<\/li>\n        <\/ul>\n        <a class=\"tr-link\" href=\"\/amorphous-alloy-transformer\/\">\n          View Amorphous Alloy Series <span>\u2192<\/span>\n        <\/a>\n      <\/div>\n      <div class=\"tr-figure-wrap\">\n        <span class=\"tr-chip\">ENERGY SAVING<\/span>\n        <div class=\"tr-figure\">\n          <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/XBRELE-SBH15-amorphous-alloy-transformer-line-art.webp\" alt=\"Engineering line art of XBRELE SBH15 amorphous alloy transformer\">\n          <div class=\"tr-figure-caption\">\n            SBH15 Series Amorphous Alloy Transformer, delivering industry-leading energy efficiency.\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-6739fcc\" data-block-id=\"6739fcc\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-6739fcc-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-128479c\" data-v=\"4\" data-block-id=\"128479c\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-128479c-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-128479c-inner-blocks\">\n<section id=\"sec4-tr-technical\" style=\"padding:90px 0; background:#F3F4F6;\">\n  <style>\n    #sec4-tr-technical .tc-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:60px;\n      align-items:center;\n    }\n    @media(max-width:900px){\n      #sec4-tr-technical .tc-shell{\n        grid-template-columns:1fr;\n      }\n    }\n\n    #sec4-tr-technical .tc-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px; \/* Original compact size *\/\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:8px;\n    }\n    #sec4-tr-technical h2{\n      font-size:28px; \/* Original compact size *\/\n      line-height: 1.35;\n      margin:0 0 16px;\n      color:#111827;\n    }\n    #sec4-tr-technical .tc-lead{\n      font-size:15px;\n      color:#4B5563;\n      margin:0 0 20px;\n      line-height:1.8;\n      max-width: 680px;\n    }\n    \n    #sec4-tr-technical ul.tc-list{\n      list-style:none;\n      padding:0;\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n    }\n    #sec4-tr-technical ul.tc-list li{\n      position: relative;\n      padding-left: 20px;\n      margin-bottom: 12px;\n      line-height: 1.6;\n    }\n    #sec4-tr-technical ul.tc-list li::before{\n      content: \"\u2022\";\n      color: #00B8B8;\n      font-weight: bold;\n      position: absolute;\n      left: 0;\n      top: 0;\n    }\n    #sec4-tr-technical ul.tc-list li strong{\n      color: #1F2937;\n    }\n\n    #sec4-tr-technical .tc-panel{\n      background:#FFFFFF;\n      border-radius:16px;\n      border:1px solid #E5E7EB;\n      padding:24px;\n      box-shadow:0 10px 30px rgba(15,23,42,.05);\n    }\n    #sec4-tr-technical table{\n      width:100%;\n      border-collapse:collapse;\n      font-size:14px;\n      color:#4B5563;\n    }\n    #sec4-tr-technical th,\n    #sec4-tr-technical td{\n      padding:12px 8px;\n      border-bottom:1px solid #E5E7EB;\n      text-align:left;\n    }\n    #sec4-tr-technical tr:last-child td{\n      border-bottom: none;\n    }\n    #sec4-tr-technical th{\n      font-weight:600;\n      color:#111827;\n      width: 40%;\n    }\n    #sec4-tr-technical td{\n      font-family: monospace, sans-serif; \/* Technical look for data *\/\n      color: #111827;\n    }\n  <\/style>\n\n  <div class=\"tc-shell\">\n    <div>\n      <div class=\"tc-kicker\">Technical Features<\/div>\n      <h2>High-Permeability Core &#038; Oxygen-Free Copper Windings<\/h2>\n\n      <p class=\"tc-lead\">\n        XBRELE transformers are engineered for low-loss stability. We utilize <strong>high-permeability grain-oriented cold-rolled silicon steel<\/strong> for the core and <strong>oxygen-free copper<\/strong> for windings, ensuring compliance with global efficiency standards.\n      <\/p>\n\n      <ul class=\"tc-list\">\n        <li><strong>Vacuum Oil Injection:<\/strong> Removes moisture completely from S11\/S13 series, preventing insulation aging and oxidation.<\/li>\n        <li><strong>Corrugated Tank Structure:<\/strong> Provides &#8220;breathing&#8221; elasticity to compensate for oil volume changes, eliminating the need for a conservator.<\/li>\n        <li><strong>F-Class Insulation:<\/strong> Our Dry-Type SCB series uses epoxy resin casting to ensure fire safety and moisture resistance suitable for 100% humidity.<\/li>\n        <li><strong>Amorphous Technology:<\/strong> SBH15 series utilizes amorphous alloy strips to reduce no-load losses by up to 75% for maximum energy efficiency.<\/li>\n      <\/ul>\n    <\/div>\n\n    <aside class=\"tc-panel\">\n      <table>\n        <thead>\n          <tr>\n            <th colspan=\"2\" style=\"padding-bottom: 16px; border-bottom: 2px solid #E5E7EB; font-size: 16px;\">General Specifications<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Rated Voltage<\/td>\n            <td>6kV \/ 10kV \/ 20kV \/ 35kV<\/td>\n          <\/tr>\n          <tr>\n            <td>Rated Capacity<\/td>\n            <td>30kVA \u2013 31,500kVA<\/td>\n          <\/tr>\n          <tr>\n            <td>Vector Group<\/td>\n            <td>Dyn11, Yyn0<\/td>\n          <\/tr>\n          <tr>\n            <td>Frequency<\/td>\n            <td>50Hz \/ 60Hz<\/td>\n          <\/tr>\n          <tr>\n            <td>Short-circuit Impedance<\/td>\n            <td>4.0% \u2013 8.0% (Standard)<\/td>\n          <\/tr>\n          <tr>\n            <td>Ambient Temperature<\/td>\n            <td>-40\u00b0C to +40\u00b0C<\/td>\n          <\/tr>\n          <tr>\n            <td>Altitude<\/td>\n            <td>\u2264 1000m (Customizable)<\/td>\n          <\/tr>\n          <tr>\n            <td>Design Standards<\/td>\n            <td>IEC 60076 \/ GB 1094<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/aside>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-571e51b\" data-block-id=\"571e51b\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-571e51b-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-e10aa34\" data-v=\"4\" data-block-id=\"e10aa34\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-e10aa34-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-e10aa34-inner-blocks\">\n<section id=\"sec5-tr-applications\" style=\"padding:90px 0; background:#FFFFFF;\">\n  <style>\n    #sec5-tr-applications .ap-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec5-tr-applications .ap-header{\n      max-width:760px;\n      margin:0 auto 48px;\n      text-align:center;\n    }\n    #sec5-tr-applications .ap-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px; \/* Original compact size *\/\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:8px;\n    }\n    #sec5-tr-applications h2{\n      font-size:28px; \/* Original compact size *\/\n      line-height: 1.35;\n      margin:0 0 12px;\n      color:#111827;\n    }\n    #sec5-tr-applications .ap-sub{\n      font-size:15px;\n      line-height: 1.8;\n      color:#4B5563;\n    }\n    \n    #sec5-tr-applications .ap-grid{\n      display:grid;\n      grid-template-columns:repeat(4,minmax(0,1fr));\n      gap:24px;\n    }\n    @media(max-width:1100px){\n      #sec5-tr-applications .ap-grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:700px){\n      #sec5-tr-applications .ap-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    \n    #sec5-tr-applications .ap-card{\n      border-radius:16px;\n      border:1px solid #E5E7EB;\n      padding:24px;\n      background:#F9FAFB;\n      transition: transform 0.3s ease, box-shadow 0.3s ease;\n    }\n    #sec5-tr-applications .ap-card:hover{\n      transform: translateY(-4px);\n      box-shadow: 0 12px 30px rgba(0,0,0,0.06);\n      background: #FFFFFF;\n      border-color: #00B8B8;\n    }\n    \n    #sec5-tr-applications .ap-card h3{\n      font-size:16px;\n      margin:0 0 10px;\n      color:#111827;\n      font-weight: 700;\n    }\n    #sec5-tr-applications .ap-card p{\n      font-size:14px;\n      line-height: 1.7;\n      color:#4B5563;\n      margin: 0;\n    }\n    #sec5-tr-applications .ap-icon{\n      font-size: 24px;\n      margin-bottom: 16px;\n      display: block;\n    }\n  <\/style>\n\n  <div class=\"ap-shell\">\n    <div class=\"ap-header\">\n      <div class=\"ap-kicker\">Key Markets<\/div>\n      <h2>Powering Critical Infrastructure Across Sectors<\/h2>\n      <p class=\"ap-sub\">\n        XBRELE transformers are engineered for resilience. From dust-heavy mining sites to strict fire-safety zones in urban centers, our equipment ensures stable power distribution in the most demanding environments.\n      <\/p>\n    <\/div>\n\n    <div class=\"ap-grid\">\n      <article class=\"ap-card\">\n        <span class=\"ap-icon\">\ud83c\udfed<\/span>\n        <h3>Heavy Industry &#038; Mining<\/h3>\n        <p>\n          Our <strong>hermetically sealed oil-immersed transformers<\/strong> (S11\/S13) are specifically suited for petroleum, metallurgy, and coal industries. The corrugated tank design withstands high-dust environments common in chemical and industrial zones.\n        <\/p>\n      <\/article>\n\n      <article class=\"ap-card\">\n        <span class=\"ap-icon\">\ud83c\udfd9\ufe0f<\/span>\n        <h3>Urban Infrastructure<\/h3>\n        <p>\n          For commercial centers, high-rise buildings, and residential districts, our <strong>SCB Dry-Type series<\/strong> offers superior fire safety. They can be installed directly in load centers to reduce line losses and ensure safe power supply.\n        <\/p>\n      <\/article>\n\n      <article class=\"ap-card\">\n        <span class=\"ap-icon\">\u2708\ufe0f<\/span>\n        <h3>Transportation Hubs<\/h3>\n        <p>\n          Providing reliable power for airports, ports, and railway transportation. Our cast resin transformers are designed to handle vibration and load fluctuations, ensuring continuous operation for critical transit infrastructure.\n        <\/p>\n      <\/article>\n\n      <article class=\"ap-card\">\n        <span class=\"ap-icon\">\u26a1<\/span>\n        <h3>Power Generation<\/h3>\n        <p>\n          Supporting power plants and regional substations. Our <strong>Amorphous Alloy (SBH15)<\/strong> and 35kV power transformers are optimized for power generation and supply networks, minimizing transmission losses.\n        <\/p>\n      <\/article>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-c977fee\" data-block-id=\"c977fee\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-c977fee-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-78976e2\" data-v=\"4\" data-block-id=\"78976e2\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-78976e2-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-78976e2-inner-blocks\">\n<section id=\"sec6-tr-why-xbrele\" style=\"padding:80px 0; background:#0F172A; color:#E5E7EB;\">\n  <style>\n    #sec6-tr-why-xbrele .wh-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec6-tr-why-xbrele .wh-header{\n      max-width:760px;\n      margin:0 auto 40px;\n      text-align:center;\n    }\n    #sec6-tr-why-xbrele .wh-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:6px;\n    }\n    #sec6-tr-why-xbrele h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#F9FAFB;\n      line-height: 1.35;\n    }\n    #sec6-tr-why-xbrele .wh-sub{\n      font-size:15px;\n      color:#9CA3AF;\n      line-height: 1.8;\n    }\n    \n    #sec6-tr-why-xbrele .wh-grid{\n      display:grid;\n      grid-template-columns:repeat(4,minmax(0,1fr));\n      gap:18px;\n      margin-top:30px;\n    }\n    @media(max-width:1100px){\n      #sec6-tr-why-xbrele .wh-grid{\n        grid-template-columns:repeat(2,minmax(0,1fr));\n      }\n    }\n    @media(max-width:700px){\n      #sec6-tr-why-xbrele .wh-grid{\n        grid-template-columns:1fr;\n      }\n    }\n    \n    #sec6-tr-why-xbrele .wh-card{\n      border-radius:16px;\n      border:1px solid rgba(148,163,184,.2);\n      padding:24px 20px;\n      background:rgba(30, 41, 59, 0.6);\n      font-size:14px;\n      color:#E5E7EB;\n      transition: background 0.3s ease;\n    }\n    #sec6-tr-why-xbrele .wh-card:hover{\n      background:rgba(30, 41, 59, 1);\n      border-color: #00B8B8;\n    }\n    \n    #sec6-tr-why-xbrele .wh-card h3{\n      font-size:16px;\n      margin:0 0 8px;\n      color:#F9FAFB;\n      font-weight: 700;\n    }\n    #sec6-tr-why-xbrele .wh-card p{\n      margin: 0;\n      line-height: 1.7;\n      color: #CBD5E1;\n    }\n  <\/style>\n\n  <div class=\"wh-shell\">\n    <div class=\"wh-header\">\n      <div class=\"wh-kicker\">Why XBRELE<\/div>\n      <h2>Manufacturing Excellence: Precision &#038; Reliability<\/h2>\n      <p class=\"wh-sub\">\n        We control every stage of production. From our Computer-Aided Design (CAD) center to our advanced testing shielding rooms, XBRELE ensures every transformer meets the highest industry standards.\n      <\/p>\n    <\/div>\n\n    <div class=\"wh-grid\">\n\n      <article class=\"wh-card\">\n        <h3>Advanced Automation<\/h3>\n        <p>\n          Our facility utilizes fully automatic aluminum foil winding machines and CNC silicon steel transverse cutting lines. This automation ensures consistent coil tension and core stacking precision for low-loss performance.\n        <\/p>\n      <\/article>\n\n      <article class=\"wh-card\">\n        <h3>Vacuum Process Control<\/h3>\n        <p>\n          We employ fully automatic vacuum drying and coating devices. This process completely removes moisture and prevents air contact during assembly, guaranteeing the insulation longevity of our hermetically sealed units.\n        <\/p>\n      <\/article>\n\n      <article class=\"wh-card\">\n        <h3>Certified Quality<\/h3>\n        <p>\n          Reliability is verified. All XBRELE transformer series have passed the rigorous type tests certification of the National Transformer Quality Supervision and Inspection Center, complying with GB and IEC standards.\n        <\/p>\n      <\/article>\n\n      <article class=\"wh-card\">\n        <h3>Global Proven Track Record<\/h3>\n        <p>\n          Trusted internationally. Our transformers are currently powering grids and industrial projects across diverse regions, with successful exports to markets including Vietnam, Malaysia, and Mongolia.\n        <\/p>\n      <\/article>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-085daaf\" data-block-id=\"085daaf\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-085daaf-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-bc7d191\" data-v=\"4\" data-block-id=\"bc7d191\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-bc7d191-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-bc7d191-inner-blocks\">\n<section id=\"sec7-tr-faq\" style=\"padding:90px 0; background:#F9FAFB;\">\n  <style>\n    #sec7-tr-faq .tr-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec7-tr-faq .tr-header{\n      max-width:760px;\n      margin:0 auto 48px;\n      text-align:center;\n    }\n    #sec7-tr-faq .tr-kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#00B8B8;\n      margin-bottom:8px;\n    }\n    #sec7-tr-faq h2{\n      font-size:28px;\n      line-height: 1.35;\n      margin:0 0 12px;\n      color:#111827;\n    }\n    #sec7-tr-faq .tr-sub{\n      font-size:15px;\n      line-height: 1.8;\n      color:#4B5563;\n    }\n    \n    \/* Accordion Container *\/\n    #sec7-tr-faq .tr-accordion{\n      max-width: 860px;\n      margin: 0 auto;\n    }\n    \n    \/* Individual Item *\/\n    #sec7-tr-faq details{\n      border-radius:12px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      margin-bottom:12px;\n      transition: all 0.2s ease;\n      overflow: hidden;\n    }\n    #sec7-tr-faq details[open]{\n      border-color:#00B8B8;\n      box-shadow:0 10px 24px rgba(15,23,42,.05);\n    }\n    \n    \/* Question Styling *\/\n    #sec7-tr-faq summary{\n      list-style:none;\n      cursor:pointer;\n      font-size:16px;\n      font-weight:600;\n      color:#111827;\n      padding: 16px 24px;\n      position: relative;\n      padding-right: 50px;\n    }\n    #sec7-tr-faq summary::-webkit-details-marker{\n      display:none;\n    }\n    \n    \/* Custom +\/- Icon *\/\n    #sec7-tr-faq summary::after{\n      content: \"+\";\n      position: absolute;\n      right: 24px;\n      top: 50%;\n      transform: translateY(-50%);\n      color: #00B8B8;\n      font-weight: 700;\n      font-size: 20px;\n      line-height: 1;\n    }\n    #sec7-tr-faq details[open] summary::after{\n      content: \"-\";\n    }\n    \n    \/* Answer Styling *\/\n    #sec7-tr-faq .tr-panel{\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n      padding: 0 24px 24px 24px;\n      border-top: 1px solid #F3F4F6;\n      margin-top: -4px;\n      padding-top: 16px;\n    }\n    \n    \/* Internal & External Links *\/\n    #sec7-tr-faq .tr-panel a{\n      color:#00B8B8;\n      text-decoration:none;\n      font-weight:600;\n      border-bottom:1px solid transparent;\n      transition:border-color 0.2s;\n    }\n    #sec7-tr-faq .tr-panel a:hover{\n      border-bottom-color:#00B8B8;\n    }\n    \n    #sec7-tr-faq .tr-cta{\n      margin-top:32px;\n      text-align:center;\n      font-size:15px;\n      color:#64748B;\n    }\n    #sec7-tr-faq .tr-cta a{\n      color:#00B8B8;\n      font-weight:600;\n      text-decoration:none;\n    }\n  <\/style>\n\n  <div class=\"tr-shell\">\n    <div class=\"tr-header\">\n      <div class=\"tr-kicker\">Technical Support<\/div>\n      <h2>FAQ: Power Distribution Transformers (10kV-35kV)<\/h2>\n      <p class=\"tr-sub\">\n        Expert answers on selecting reliable <strong>Power Distribution Transformers<\/strong>. Learn about our S13 Oil-Immersed, SCB Dry-Type, and 35kV power solutions for global grids.\n      <\/p>\n    <\/div>\n\n    <div class=\"tr-accordion\">\n\n      <details>\n        <summary>Why choose S13 Series Power Distribution Transformers over S11?<\/summary>\n        <div class=\"tr-panel\">\n          The S13 series represents the latest generation of <strong>Power Distribution Transformers<\/strong>. Utilizing a 3D wound core, S13 models reduce no-load losses by 30% compared to S11. This makes them a superior choice for 10kV and 20kV distribution networks requiring high efficiency and lower noise levels.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>When to use a Dry-Type Power Distribution Transformer?<\/summary>\n        <div class=\"tr-panel\">\n          <strong>Dry-Type Power Distribution Transformers<\/strong> (SCB Series) are essential for indoor environments like high-rise buildings, subways, or hospitals where fire safety is critical. Unlike oil units, they are self-extinguishing. We also manufacture <strong>35kV Dry-Type Transformers<\/strong> for indoor high-voltage substations.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>What standards do your Power Distribution Transformers meet?<\/summary>\n        <div class=\"tr-panel\">\n          As a leading <strong>Transformer Manufacturer<\/strong>, XBRELE ensures all units comply with IEC 60076 and GB 1094 standards. Our design protocols align with global best practices outlined by the <a href=\"https:\/\/www.ieee.org\/\" target=\"_blank\" rel=\"dofollow noopener\">Institute of Electrical and Electronics Engineers (IEEE)<\/a>, ensuring safety and reliability for international grids.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>Are your Oil-Immersed Transformers maintenance-free?<\/summary>\n        <div class=\"tr-panel\">\n          Yes. Our S11 and S13 <strong>Oil-Immersed Power Distribution Transformers<\/strong> feature a hermetically sealed corrugated tank. This design eliminates the oil conservator and isolates the oil from air, preventing oxidation. This makes them virtually maintenance-free for outdoor distribution applications.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>Do you supply 35kV Power Transformers for substations?<\/summary>\n        <div class=\"tr-panel\">\n          Yes. We manufacture the SZ-35kV Series, a double-winding <strong>35kV Power Transformer<\/strong> with On-Load Tap Changing (OLTC). It is designed for main substations to regulate voltage effectively across 35kV transmission lines down to 10kV distribution levels.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>Can your 10kV Transformers handle 20kV switching?<\/summary>\n        <div class=\"tr-panel\">\n          Yes. We offer dual-voltage <strong>Power Distribution Transformers<\/strong> (e.g., S11-M-10\/20kV). These units feature a switchable tap changer, allowing the transformer to operate at either <strong>10kV or 20kV<\/strong>, providing flexibility for grid upgrades without replacing the equipment.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>How do Amorphous Alloy Transformers reduce costs?<\/summary>\n        <div class=\"tr-panel\">\n          Our SBH15 Amorphous Alloy <strong>Power Distribution Transformers<\/strong> use advanced amorphous metal cores. This technology lowers no-load losses by up to 75% compared to silicon steel units, significantly reducing operational costs (OPEX) for rural power distribution and renewable energy farms.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>What is the overload capacity of your transformers?<\/summary>\n        <div class=\"tr-panel\">\n          XBRELE <strong>Power Distribution Transformers<\/strong> are designed with a robust thermal margin. Our oil-immersed and dry-type units can withstand short-term overloads (e.g., 120% load) without damaging insulation, ensuring reliability during peak demand in industrial power distribution.\n        <\/div>\n      <\/details>\n\n      <details>\n        <summary>Do you offer transformers for high-altitude regions?<\/summary>\n        <div class=\"tr-panel\">\n          Yes. While standard <strong>Power Distribution Transformers<\/strong> are rated for 1000m, we provide customized plateau-type units for altitudes up to 3500m. These feature enhanced external insulation and cooling to ensure stable performance in high-altitude mining or grid applications.\n        <\/div>\n      <\/details>\n\n    <\/div>\n\n    <div class=\"tr-cta\">\n      Looking for a reliable <strong>Transformer Manufacturer<\/strong>? <a href=\"\/contact\/\">Contact XBRELE<\/a> for a quote on 10kV-35kV Power Distribution Transformers.\n    <\/div>\n\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>HV &#038; MV POWER SOLUTIONS Power Distribution Transformers Manufacturer (10kV &#8211; 35kV) XBRELE is a specialized Power Distribution Transformers manufacturer delivering high-efficiency solutions for global grids. From hermetically sealed oil-immersed S13 units to fire-safe cast resin dry-type models, our step-down transformers are certified to IEC 60076 standards. As an OEM provider, we integrate automatic foil [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1304","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"bottom","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=1304"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1304\/revisions"}],"predecessor-version":[{"id":1320,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1304\/revisions\/1320"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=1304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}