{"id":1345,"date":"2025-11-26T13:13:37","date_gmt":"2025-11-26T13:13:37","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1345"},"modified":"2025-12-05T06:36:31","modified_gmt":"2025-12-05T06:36:31","slug":"amorphous-alloy-transformer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/amorphous-alloy-transformer\/","title":{"rendered":"\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0437 \u0430\u043c\u043e\u0440\u0444\u043d\u043e\u0433\u043e \u0441\u043f\u043b\u0430\u0432\u0430"},"content":{"rendered":"\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-299e0a3\" data-block-id=\"299e0a3\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-299e0a3-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-b057900\" data-v=\"4\" data-block-id=\"b057900\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-b057900-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-b057900-inner-blocks\">\n<section id=\"sec1-amorphous-hero\" style=\"position:relative;overflow:hidden;background:radial-gradient(circle at top left,#0f172a 0,#020617 55%,#020617 100%);color:#e5e7eb;padding:200px 0 128px;\">\n  <style>\n    #sec1-amorphous-hero{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n    }\n    #sec1-amorphous-hero .hero-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec1-amorphous-hero .hero-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.3fr) minmax(0,1fr);\n      gap:48px;\n      align-items:center;\n    }\n    #sec1-amorphous-hero .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38bdf8;\n      margin-bottom:10px;\n    }\n    #sec1-amorphous-hero h1{\n      font-size:40px;\n      line-height:1.1;\n      letter-spacing:-.03em;\n      margin:0 0 14px;\n      color:#f9fafb;\n    }\n    #sec1-amorphous-hero p.sub{\n      max-width:660px;\n      font-size:16px;\n      line-height:1.75;\n      margin:0 0 20px;\n      color:#cbd5f5;\n      text-wrap:balance;\n    }\n    #sec1-amorphous-hero .badges{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:22px 0 32px;\n    }\n    #sec1-amorphous-hero .badge{\n      padding:6px 12px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid rgba(148,163,184,.55);\n      background:rgba(15,23,42,.45);\n      backdrop-filter:blur(14px);\n      color:#e5e7eb;\n    }\n\n    \/* \u5361\u7247\u6837\u5f0f\uff0c\u4fdd\u6301\u4e00\u81f4 *\/\n    #sec1-amorphous-hero .hero-card{\n      position:relative;\n      border-radius:20px;\n      padding:22px 22px 18px;\n      background:radial-gradient(circle at top left,rgba(56,189,248,.20) 0,\n        rgba(15,23,42,.95) 36%,rgba(15,23,42,1) 100%);\n      border:1px solid rgba(148,163,184,.4);\n      box-shadow:0 18px 45px rgba(15,23,42,.9);\n      color:#e5e7eb;\n    }\n    #sec1-amorphous-hero .hero-card h3{\n      font-size:15px;\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      color:#bae6fd;\n      margin:0 0 10px;\n    }\n    #sec1-amorphous-hero .hero-card p{\n      font-size:13px;\n      line-height:1.7;\n      color:#cbd5f5;\n      margin:0 0 16px;\n    }\n    #sec1-amorphous-hero .spec-grid{\n      display:grid;\n      grid-template-columns:repeat(2,minmax(0,1fr));\n      gap:12px 20px;\n      font-size:12px;\n    }\n    .spec-label{\n      text-transform:uppercase;\n      letter-spacing:.12em;\n      color:#9ca3af;\n      margin-bottom:2px;\n      font-size:11px;\n    }\n    .spec-value{\n      font-weight:500;\n      color:#e5e7eb;\n    }\n\n    @media(max-width:1000px){\n      #sec1-amorphous-hero .hero-grid{grid-template-columns:1fr;}\n    }\n    @media(max-width:690px){\n      #sec1-amorphous-hero h1{font-size:30px;}\n      #sec1-amorphous-hero .hero-shell{padding:0 18px;}\n    }\n  <\/style>\n\n  <div class=\"hero-shell\">\n    <div class=\"hero-grid\">\n\n      <!-- Left Content -->\n      <div>\n        <div class=\"kicker\">Power Distribution Transformers<\/div>\n\n        <h1>Amorphous Alloy Transformer (SBH15-M \/ SCBH15 Series)<\/h1>\n\n        <p class=\"sub\">\n          XBRELE\u2019s <strong>amorphous alloy transformer<\/strong> series includes the SBH15-M oil-immersed\n          range (5\u2013160&nbsp;kVA) and SCBH15 dry-type units (30\u20132500&nbsp;kVA). With significantly lower\n          no-load loss compared to silicon steel transformers, these high-efficiency models are designed\n          for 6\u201311&nbsp;kV distribution networks requiring energy savings and reduced OPEX.\n        <\/p>\n\n        <div class=\"badges\">\n          <span class=\"badge\">SBH15-M<\/span>\n          <span class=\"badge\">SCBH15<\/span>\n          <span class=\"badge\">Low Loss Core<\/span>\n          <span class=\"badge\">5\u20132500 kVA<\/span>\n        <\/div>\n      <\/div>\n\n      <!-- Right Card -->\n      <aside class=\"hero-card\">\n        <h3>Series Overview<\/h3>\n        <p>\n          Two transformer types designed for different installation environments:\n          oil-immersed SBH15-M for outdoor poles and ground-mounted sites,\n          and SCBH15 dry-type for indoor, compact, or fire-sensitive distribution stations.\n        <\/p>\n\n        <div class=\"spec-grid\">\n          <div>\n            <div class=\"spec-label\">Primary Voltage<\/div>\n            <div class=\"spec-value\">6 \/ 10 \/ 11 kV<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Secondary Voltage<\/div>\n            <div class=\"spec-value\">0.22 \/ 0.24 \/ 0.4 kV<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Capacity Range<\/div>\n            <div class=\"spec-value\">5 \u2013 2500 kVA<\/div>\n          <\/div>\n          <div>\n            <div class=\"spec-label\">Core Material<\/div>\n            <div class=\"spec-value\">Amorphous Alloy<\/div>\n          <\/div>\n        <\/div>\n      <\/aside>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-84024ad\" data-block-id=\"84024ad\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-84024ad-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-64c5be1\" data-v=\"4\" data-block-id=\"64c5be1\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-64c5be1-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-64c5be1-inner-blocks\">\n<section id=\"sec2-amorphous-overview\" style=\"background:#ffffff;padding:90px 0 105px;color:#0f172a;\">\n  <style>\n    \/* \u6837\u5f0f\u4fdd\u6301\u4e0d\u53d8\uff0c\u4ec5\u66ff\u6362\u4e3aAmorphous Alloy Transformer\u4e13\u7528 ID *\/\n    #sec2-amorphous-overview{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;}\n    #sec2-amorphous-overview .ckg-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec2-amorphous-overview .overview-grid{display:grid;grid-template-columns:minmax(0,1.4fr) minmax(0,1fr);gap:52px;align-items:center;}\n    #sec2-amorphous-overview .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38bdf8;margin-bottom:10px;}\n    #sec2-amorphous-overview h2{font-size:28px;margin:0 0 14px;color:#0f172a;}\n    #sec2-amorphous-overview p{font-size:16px;line-height:1.85;margin:0 0 16px;color:#4b5563;}\n    #sec2-amorphous-overview .apps-box{background:#f9fafb;padding:22px 24px 20px;border-radius:18px;border:1px solid #e5e7eb;}\n    #sec2-amorphous-overview .apps-box h3{font-size:15px;margin:0 0 12px;text-transform:uppercase;letter-spacing:.14em;color:#6b7280;}\n    #sec2-amorphous-overview ul{list-style:none;padding:0;margin:0;display:grid;gap:10px;font-size:14px;color:#374151;}\n    #sec2-amorphous-overview ul li{position:relative;padding-left:16px;line-height:1.7;}\n    #sec2-amorphous-overview ul li::before{content:\"\";position:absolute;left:0;top:8px;width:6px;height:6px;border-radius:999px;background:#38bdf8;}\n    @media(max-width:1000px){#sec2-amorphous-overview .overview-grid{grid-template-columns:1fr;}}\n  <\/style>\n\n  <div class=\"ckg-shell\">\n    <div class=\"overview-grid\">\n      <div>\n        <div class=\"kicker\">Amorphous Alloy Transformer Overview<\/div>\n        <h2>Low Loss Amorphous Alloy Transformer for Energy-Efficient Distribution<\/h2>\n\n        <p>\n          The <strong>amorphous alloy transformer<\/strong> uses an amorphous metal core instead of traditional silicon\n          steel laminations, dramatically reducing core loss. By combining optimized magnetic properties with\n          high-quality windings, XBRELE SBH15-M oil-immersed and SCBH15 dry-type designs help utilities and industrial\n          users cut no-load loss and improve overall grid efficiency.\n        <\/p>\n\n        <p>\n          Compared with a conventional silicon steel distribution transformer, an <strong>amorphous core transformer<\/strong>\n          can reduce no-load loss by 60\u201370% in many cases, which directly translates into lower lifetime energy\n          consumption. This makes the amorphous alloy transformer a preferred <strong>low loss transformer<\/strong> option\n          for projects that focus on energy saving, carbon reduction and long-term OPEX control.\n        <\/p>\n\n        <p>\n          XBRELE engineers design each <strong>amorphous alloy distribution transformer<\/strong> according to\n          international power transformer standards such as \n          <a href=\"https:\/\/webstore.iec.ch\/publication\/223\" style=\"color:#2563EB;text-decoration:none;\" target=\"_blank\" rel=\"noopener\">\n            IEC&nbsp;60076-1 power transformers\n          <\/a>, ensuring insulation coordination, temperature rise and short-circuit strength are fully verified.\n          When customers compare <em>silicon steel vs amorphous<\/em> solutions for 6\u201311&nbsp;kV networks, these\n          high efficiency distribution transformers provide a clear technical and economic advantage.\n        <\/p>\n\n        <p style=\"margin-top:14px;font-size:14px;color:#4b5563;\">\n          For a broader view of oil-immersed, dry-type and other <strong>energy efficient transformer<\/strong> options,\n          please visit the\n          <a href=\"https:\/\/xbrele.com\/power-distribution-transformers\/\" style=\"color:#2563EB;text-decoration:none;\">\n            Power Distribution Transformers pillar page\n          <\/a>, where XBRELE presents its complete distribution transformer solutions.\n        <\/p>\n      <\/div>\n\n      <aside class=\"apps-box\">\n        <h3>Typical Applications<\/h3>\n        <ul>\n          <li><strong>Urban &amp; Rural Distribution Networks:<\/strong> Pole-mounted and ground-mounted amorphous alloy transformers for 6\u201311&nbsp;kV feeders.<\/li>\n          <li><strong>Energy-Saving Retrofit Projects:<\/strong> Replacing old silicon steel units with <strong>high efficiency distribution transformer<\/strong> solutions.<\/li>\n          <li><strong>Industrial Plants &amp; Commercial Parks:<\/strong> Low loss transformer installations to reduce operating costs and CO\u2082 emissions.<\/li>\n          <li><strong>Government &amp; Utility Green Programs:<\/strong> Amorphous core transformer deployments in projects with strict energy-efficiency targets.<\/li>\n        <\/ul>\n      <\/aside>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-e1c656c\" data-block-id=\"e1c656c\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-e1c656c-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-89ed265\" data-v=\"4\" data-block-id=\"89ed265\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-89ed265-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-89ed265-inner-blocks\">\n<section id=\"sec3-amorphous-tech\" style=\"padding:90px 0;background:#F9FAFB;\">\n  <style>\n    #sec3-amorphous-tech{\n      font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;\n      color:#0F172A;\n    }\n    #sec3-amorphous-tech .tech-shell{\n      max-width:1600px;\n      margin:0 auto;\n      padding:0 5vw;\n    }\n    #sec3-amorphous-tech .sec-header{\n      max-width:820px;\n      margin:0 auto 32px;\n      text-align:center;\n    }\n    #sec3-amorphous-tech .kicker{\n      text-transform:uppercase;\n      letter-spacing:.16em;\n      font-size:12px;\n      font-weight:600;\n      color:#38BDF8;\n      margin-bottom:8px;\n    }\n    #sec3-amorphous-tech h2{\n      font-size:28px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-amorphous-tech .sec-header p{\n      margin:0;\n      font-size:15px;\n      color:#4B5563;\n      line-height:1.8;\n    }\n\n    \/* TAB buttons *\/\n    #sec3-amorphous-tech .tab-row{\n      display:flex;\n      flex-wrap:wrap;\n      justify-content:center;\n      gap:10px;\n      margin:34px 0 32px;\n    }\n    #sec3-amorphous-tech .tab-btn{\n      padding:10px 22px;\n      font-size:14px;\n      font-weight:600;\n      background:#E5E7EB;\n      border-radius:999px;\n      cursor:pointer;\n      border:1px solid #D1D5DB;\n      transition:all .25s ease;\n      color:#0F172A;\n      white-space:nowrap;\n    }\n    #sec3-amorphous-tech .tab-btn:hover{\n      background:#DDE3E9;\n    }\n    #sec3-amorphous-tech .tab-btn.active{\n      background:#0F172A;\n      color:#F9FAFB;\n      border-color:#0F172A;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n    }\n\n    \/* tab content *\/\n    #sec3-amorphous-tech .tab-content{\n      display:none;\n      animation:fadeIn .25s ease;\n    }\n    #sec3-amorphous-tech .tab-content.active{\n      display:block;\n    }\n    @keyframes fadeIn{\n      from{opacity:0;transform:translateY(6px);}\n      to{opacity:1;transform:translateY(0);}\n    }\n\n    \/* card + grid *\/\n    #sec3-amorphous-tech .panel-card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#FFFFFF;\n      padding:24px 22px 30px;\n      box-shadow:0 14px 32px rgba(15,23,42,.05);\n    }\n    #sec3-amorphous-tech .panel-grid{\n      display:grid;\n      grid-template-columns:minmax(0,1.15fr) minmax(0,1.1fr);\n      gap:22px;\n      margin-bottom:24px;\n      align-items:flex-start;\n    }\n\n    \/* image *\/\n    #sec3-amorphous-tech .main-fig-large{\n      margin:0;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:10px;\n    }\n    #sec3-amorphous-tech .main-fig-large img{\n      display:block;\n      width:100%;\n      max-height:320px;\n      object-fit:contain;\n    }\n    #sec3-amorphous-tech .main-fig-large figcaption{\n      margin-top:8px;\n      font-size:12px;\n      color:#6B7280;\n      line-height:1.6;\n    }\n\n    \/* right text *\/\n    #sec3-amorphous-tech .panel-right h3{\n      font-size:16px;\n      margin:0 0 10px;\n      color:#0F172A;\n    }\n    #sec3-amorphous-tech .panel-right p{\n      font-size:14px;\n      line-height:1.8;\n      margin:0 0 10px;\n      color:#4B5563;\n    }\n    #sec3-amorphous-tech .badge-row{\n      display:flex;\n      flex-wrap:wrap;\n      gap:8px;\n      margin:8px 0 14px;\n    }\n    #sec3-amorphous-tech .badge{\n      padding:4px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      border:1px solid #D1D5DB;\n      background:#F9FAFB;\n      color:#4B5563;\n    }\n\n    \/* tables *\/\n    #sec3-amorphous-tech .block-title{\n      font-size:14px;\n      font-weight:600;\n      margin:12px 0 6px;\n      color:#111827;\n    }\n    #sec3-amorphous-tech .table-wrap{\n      width:100%;\n      overflow-x:auto;\n      border-radius:14px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      margin-bottom:18px;\n      box-shadow:inset -10px 0 10px -10px rgba(0,0,0,0.05);\n    }\n    #sec3-amorphous-tech table{\n      width:100%;\n      border-collapse:separate;\n      border-spacing:0;\n      font-size:13px;\n      min-width:620px;\n    }\n    #sec3-amorphous-tech th,\n    #sec3-amorphous-tech td{\n      padding:10px 12px;\n      border-bottom:1px solid #E5E7EB;\n      text-align:left;\n      color:#111827;\n      white-space:nowrap;\n    }\n    #sec3-amorphous-tech thead{\n      background:#E5F0FF;\n    }\n    #sec3-amorphous-tech th{\n      font-size:12px;\n      text-transform:uppercase;\n      letter-spacing:.08em;\n      color:#374151;\n      font-weight:600;\n    }\n    #sec3-amorphous-tech tbody tr:nth-child(odd){background:#FFFFFF;}\n    #sec3-amorphous-tech tbody tr:nth-child(even){background:#F9FAFB;}\n\n    #sec3-amorphous-tech th:first-child,\n    #sec3-amorphous-tech td:first-child{\n      position:sticky;\n      left:0;\n      z-index:2;\n      border-right:2px solid #E5E7EB;\n    }\n    #sec3-amorphous-tech thead th:first-child{\n      background:#E5F0FF;\n      z-index:3;\n    }\n    #sec3-amorphous-tech tbody tr:nth-child(odd) td:first-child{background:#FFFFFF;}\n    #sec3-amorphous-tech tbody tr:nth-child(even) td:first-child{background:#F9FAFB;}\n\n    \/* CTA *\/\n    #sec3-amorphous-tech .cta-right-col{\n      display:flex;\n      justify-content:center;\n      margin-top:26px;\n    }\n    #sec3-amorphous-tech .cta-btn{\n      display:inline-block;\n      padding:12px 30px;\n      background:#0F172A;\n      color:#F9FAFB;\n      font-size:15px;\n      font-weight:600;\n      border-radius:8px;\n      text-decoration:none;\n      letter-spacing:.03em;\n      transition:all .25s ease;\n      box-shadow:0 10px 24px rgba(15,23,42,.18);\n      white-space:nowrap;\n    }\n    #sec3-amorphous-tech .cta-btn:hover{\n      background:#1E293B;\n      box-shadow:0 14px 32px rgba(15,23,42,.25);\n      transform:translateY(-1px);\n    }\n\n    @media(max-width:1000px){\n      #sec3-amorphous-tech .panel-grid{grid-template-columns:1fr;}\n    }\n    @media(max-width:690px){\n      #sec3-amorphous-tech .tech-shell{padding:0 18px;}\n      #sec3-amorphous-tech h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"tech-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Technical Specifications<\/div>\n      <h2>Amorphous Alloy Transformer Technical Data by Series<\/h2>\n      <p>\n        XBRELE SBH15-M oil-immersed and SCBH15 dry-type amorphous alloy transformer series provide\n        <strong>low loss transformer<\/strong> solutions for utilities and industrial users who focus on\n        <strong>energy efficient transformer<\/strong> performance and lifetime operating cost, offering\n        a high efficiency distribution transformer alternative in the discussion of silicon steel vs amorphous cores.\n      <\/p>\n    <\/div>\n\n    <!-- main tabs -->\n    <div class=\"tab-row\">\n      <div class=\"tab-btn active\" data-tab=\"sbh15m-oil\">SBH15-M Oil-Immersed Amorphous Alloy<\/div>\n      <div class=\"tab-btn\" data-tab=\"scbh15-dry\">SCBH15 Dry-Type Amorphous Alloy<\/div>\n    <\/div>\n\n    <!-- TAB 1: SBH15-M -->\n    <div id=\"sbh15m-oil\" class=\"tab-content active\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <div>\n            <figure class=\"main-fig-large\">\n              <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/xbrele-sbh15-m-amorphous-alloy-transformer-main.webp\"\n                   alt=\"XBRELE SBH15-M oil-immersed amorphous alloy distribution transformer with low loss and high efficiency performance\">\n              <figcaption>\n                SBH15-M oil-immersed amorphous alloy distribution transformer series, designed as a\n                high efficiency distribution transformer to replace conventional silicon steel core units\n                in outdoor power distribution networks.\n              <\/figcaption>\n            <\/figure>\n          <\/div>\n          <div class=\"panel-right\">\n            <h3>SBH15-M Oil-Immersed Amorphous Alloy Distribution Transformers<\/h3>\n            <p>\n              SBH15-M adopts an amorphous alloy iron core and hermetically sealed tank structure.\n              Compared with traditional silicon steel transformers, it significantly reduces no-load loss,\n              helping utilities and project owners cut OPEX while improving grid efficiency.\n            <\/p>\n            <p>\n              The product is suitable for rural and urban distribution networks, energy conservation retrofits,\n              and government green energy projects that require a <strong>low loss transformer<\/strong>\n              with reliable outdoor performance.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">Oil-immersed<\/span>\n              <span class=\"badge\">SBH15-M<\/span>\n              <span class=\"badge\">Amorphous Alloy Core<\/span>\n              <span class=\"badge\">Outdoor Distribution<\/span>\n            <\/div>\n          <\/div>\n        <\/div>\n\n        <!-- SBH15-M single-phase only -->\n        <p class=\"block-title\">\n          Main Technical Parameters \u2014 5kVA\u2013160kVA Single-Phase SBH15-M Amorphous Alloy Distribution Transformer\n        <\/p>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th>Rated Capacity (kVA)<\/th>\n                <th>High Voltage (kV)<\/th>\n                <th>HV Tap Range (%)<\/th>\n                <th>Low Voltage (kV)<\/th>\n                <th>Join Group<\/th>\n                <th>No-load Loss (W)<\/th>\n                <th>Load Loss (W)<\/th>\n                <th>No-load Current (%)<\/th>\n                <th>Impedance (%)<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <tr><td>5<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>15<\/td><td>130<\/td><td>2.0<\/td><td>4.0<\/td><\/tr>\n              <tr><td>10<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>23<\/td><td>235<\/td><td>2.0<\/td><td>4.0<\/td><\/tr>\n              <tr><td>16<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>30<\/td><td>330<\/td><td>1.8<\/td><td>4.0<\/td><\/tr>\n              <tr><td>25<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>40<\/td><td>495<\/td><td>1.8<\/td><td>4.0<\/td><\/tr>\n              <tr><td>30<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>45<\/td><td>580<\/td><td>1.8<\/td><td>4.0<\/td><\/tr>\n              <tr><td>40<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>55<\/td><td>780<\/td><td>1.6<\/td><td>4.0<\/td><\/tr>\n              <tr><td>50<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>60<\/td><td>920<\/td><td>1.6<\/td><td>4.0<\/td><\/tr>\n              <tr><td>63<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>70<\/td><td>1100<\/td><td>1.5<\/td><td>4.0<\/td><\/tr>\n              <tr><td>80<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>85<\/td><td>1350<\/td><td>1.5<\/td><td>4.0<\/td><\/tr>\n              <tr><td>100<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>100<\/td><td>1600<\/td><td>1.3<\/td><td>4.0<\/td><\/tr>\n              <tr><td>125<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>115<\/td><td>1950<\/td><td>1.3<\/td><td>4.0<\/td><\/tr>\n              <tr><td>160<\/td><td>10<\/td><td>\u00b12\u00d72.5 \/ \u00b15<\/td><td>0.22 \/ 0.24<\/td><td>I0<\/td><td>135<\/td><td>2350<\/td><td>1.2<\/td><td>4.0<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n        <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n          Note: 5\u2013160kVA single-phase SBH15-M oil-immersed amorphous alloy transformer.\n          High voltage 10kV, low voltage 0.22\/0.24kV, tap range \u00b12\u00d72.5% or \u00b15%, connection group I0.\n          Data according to the SBH15-M single-phase catalogue.\n        <\/p>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">Request SBH15-M Amorphous Quote<\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n\n\n    <!-- TAB 2: SCBH15 -->\n    <div id=\"scbh15-dry\" class=\"tab-content\">\n      <div class=\"panel-card\">\n        <div class=\"panel-grid\">\n          <div>\n            <figure class=\"main-fig-large\">\n              <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/xbrele-scbh15-dry-type-amorphous-alloy-transformer-main.webp\"\n                   alt=\"XBRELE SCBH15 dry-type amorphous alloy transformer for indoor substations with low loss core and energy-efficient operation\">\n              <figcaption>\n                SCBH15 dry-type amorphous alloy transformer series with epoxy casting and copper foil low-voltage windings,\n                ideal for indoor substations, commercial buildings and projects focusing on energy efficient transformer design.\n              <\/figcaption>\n            <\/figure>\n          <\/div>\n          <div class=\"panel-right\">\n            <h3>SCBH15 Dry-Type Amorphous Alloy Distribution Transformers<\/h3>\n            <p>\n              SCBH15 uses an amorphous alloy strip core and epoxy cast windings to provide a fire-safe,\n              maintenance-free <strong>low loss transformer<\/strong> for indoor applications. Compared with\n              silicon steel core dry-type transformers, the amorphous core offers much lower no-load loss\n              and improves overall energy efficiency.\n            <\/p>\n            <p>\n              Typical applications include indoor substations, public buildings, commercial complexes and\n              data centers where high efficiency distribution transformer performance and reduced lifecycle\n              operating cost are critical.\n            <\/p>\n            <div class=\"badge-row\">\n              <span class=\"badge\">Dry type<\/span>\n              <span class=\"badge\">SCBH15<\/span>\n              <span class=\"badge\">Epoxy Casting<\/span>\n              <span class=\"badge\">Indoor Substations<\/span>\n            <\/div>\n          <\/div>\n        <\/div>\n\n        <p class=\"block-title\">\n          Main Technical Parameters \u2014 30kVA\u20132500kVA SCBH15 Dry-Type Amorphous Alloy Iron Core Distribution Transformer\n        <\/p>\n        <div class=\"table-wrap\">\n          <table>\n            <thead>\n              <tr>\n                <th>Rated Capacity (kVA)<\/th>\n                <th>High Voltage (kV)<\/th>\n                <th>HV Tap Range (%)<\/th>\n                <th>Low Voltage (kV)<\/th>\n                <th>Join Group<\/th>\n                <th>No-load Loss (W)<\/th>\n                <th>Load Loss 100\u00b0C (W)<\/th>\n                <th>Load Loss 120\u00b0C (W)<\/th>\n                <th>Load Loss 145\u00b0C (W)<\/th>\n                <th>No-load Current (%)<\/th>\n                <th>Impedance (%)<\/th>\n              <\/tr>\n            <\/thead>\n            <tbody>\n              <!-- Z = 4.0% -->\n              <tr><td>30<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>70<\/td><td>670<\/td><td>710<\/td><td>760<\/td><td>1.6<\/td><td>4.0<\/td><\/tr>\n              <tr><td>50<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>90<\/td><td>940<\/td><td>1000<\/td><td>1070<\/td><td>1.4<\/td><td>4.0<\/td><\/tr>\n              <tr><td>80<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>120<\/td><td>1290<\/td><td>1380<\/td><td>1480<\/td><td>1.3<\/td><td>4.0<\/td><\/tr>\n              <tr><td>100<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>130<\/td><td>1480<\/td><td>1570<\/td><td>1690<\/td><td>1.2<\/td><td>4.0<\/td><\/tr>\n              <tr><td>125<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>150<\/td><td>1740<\/td><td>1850<\/td><td>1980<\/td><td>1.1<\/td><td>4.0<\/td><\/tr>\n              <tr><td>160<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>170<\/td><td>2000<\/td><td>2130<\/td><td>2280<\/td><td>1.1<\/td><td>4.0<\/td><\/tr>\n              <tr><td>200<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>200<\/td><td>2370<\/td><td>2530<\/td><td>2710<\/td><td>1.0<\/td><td>4.0<\/td><\/tr>\n              <tr><td>250<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>230<\/td><td>2590<\/td><td>2760<\/td><td>2960<\/td><td>1.0<\/td><td>4.0<\/td><\/tr>\n              <tr><td>315<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>280<\/td><td>3270<\/td><td>3470<\/td><td>3730<\/td><td>0.9<\/td><td>4.0<\/td><\/tr>\n              <tr><td>400<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>310<\/td><td>3750<\/td><td>3990<\/td><td>4280<\/td><td>0.8<\/td><td>4.0<\/td><\/tr>\n              <tr><td>500<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>360<\/td><td>4590<\/td><td>4880<\/td><td>5230<\/td><td>0.8<\/td><td>4.0<\/td><\/tr>\n              <tr><td>630<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b12.5 \/ \u00b15<\/td><td>0.4<\/td><td>Dyn11<\/td><td>420<\/td><td>5530<\/td><td>5880<\/td><td>6290<\/td><td>0.7<\/td><td>4.0<\/td><\/tr>\n\n              <!-- Z = 6.0% -->\n              <tr><td>630<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>410<\/td><td>5610<\/td><td>5960<\/td><td>6400<\/td><td>0.7<\/td><td>6.0<\/td><\/tr>\n              <tr><td>800<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>480<\/td><td>6550<\/td><td>6960<\/td><td>7460<\/td><td>0.7<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1000<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>550<\/td><td>7650<\/td><td>8130<\/td><td>8760<\/td><td>0.6<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1250<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>650<\/td><td>9100<\/td><td>9690<\/td><td>10370<\/td><td>0.6<\/td><td>6.0<\/td><\/tr>\n              <tr><td>1600<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>760<\/td><td>11050<\/td><td>11730<\/td><td>12580<\/td><td>0.6<\/td><td>6.0<\/td><\/tr>\n              <tr><td>2000<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>1000<\/td><td>13600<\/td><td>14450<\/td><td>15560<\/td><td>0.5<\/td><td>6.0<\/td><\/tr>\n              <tr><td>2500<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>1200<\/td><td>16150<\/td><td>17170<\/td><td>18450<\/td><td>0.5<\/td><td>6.0<\/td><\/tr>\n\n              <!-- Z = 8.0% optional -->\n              <tr><td>1600<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>760<\/td><td>12280<\/td><td>12960<\/td><td>13900<\/td><td>0.6<\/td><td>8.0<\/td><\/tr>\n              <tr><td>2000<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>1000<\/td><td>15020<\/td><td>15960<\/td><td>17110<\/td><td>0.5<\/td><td>8.0<\/td><\/tr>\n              <tr><td>2500<\/td><td>6 \/ 10 \/ 10.5 \/ 11<\/td><td>\u00b15 \/ \u00b12\u00d72.5<\/td><td>0.4<\/td><td>Dyn11<\/td><td>1200<\/td><td>17760<\/td><td>18890<\/td><td>20290<\/td><td>0.5<\/td><td>8.0<\/td><\/tr>\n            <\/tbody>\n          <\/table>\n        <\/div>\n        <p style=\"font-size:13px;color:#64748B;margin-top:8px;\">\n          Note: 30\u20132500kVA SCBH15 dry-type amorphous alloy transformer. High voltage 6 \/ 10 \/ 10.5 \/ 11kV,\n          low voltage 0.4kV, connection group Dyn11. Short-circuit impedance 4 \/ 6 \/ 8% depends on capacity\n          and tap configuration. Load loss values at 100\u00b0C \/ 120\u00b0C \/ 145\u00b0C correspond to insulation classes\n          in GB\/T standards and should be confirmed with the latest XBRELE catalogue when selecting models.\n        <\/p>\n\n        <div class=\"cta-right-col\">\n          <a href=\"#ct-popup-882\" class=\"cta-btn\">Request SCBH15 Amorphous Quote<\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <script>\n    (function(){\n      const root = document.getElementById('sec3-amorphous-tech');\n      if(!root) return;\n      const mainBtns = root.querySelectorAll('.tab-btn');\n      const mainTabs = root.querySelectorAll('.tab-content');\n\n      mainBtns.forEach(btn=>{\n        btn.addEventListener('click',()=>{\n          const target = btn.getAttribute('data-tab');\n          mainBtns.forEach(b=>b.classList.remove('active'));\n          mainTabs.forEach(t=>t.classList.remove('active'));\n          btn.classList.add('active');\n          const tab = root.querySelector('#'+target);\n          if(tab) tab.classList.add('active');\n        });\n      });\n    })();\n  <\/script>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-e6e716d\" data-block-id=\"e6e716d\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-e6e716d-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-428d62d\" data-v=\"4\" data-block-id=\"428d62d\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-428d62d-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-428d62d-inner-blocks\">\n<section id=\"sec4-amorphous-features\" style=\"background:#ffffff;padding:90px 0 100px;\">\n  <style>\n    #sec4-amorphous-features{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n    #sec4-amorphous-features .features-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec4-amorphous-features .sec-header{max-width:820px;margin:0 auto 40px;text-align:center;}\n    #sec4-amorphous-features .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec4-amorphous-features h2{font-size:28px;margin:0 0 10px;color:#0F172A;}\n    #sec4-amorphous-features .sec-header p{margin:0;font-size:15px;color:#4B5563;line-height:1.8;}\n\n    #sec4-amorphous-features .grid{\n      display:grid;\n      grid-template-columns:repeat(3,minmax(0,1fr));\n      gap:24px;\n      margin-top:40px;\n    }\n\n    #sec4-amorphous-features .card{\n      border-radius:20px;\n      border:1px solid #E5E7EB;\n      background:#F9FAFB;\n      padding:22px 22px 24px;\n      box-shadow:0 14px 32px rgba(15,23,42,.04);\n      display:flex;\n      flex-direction:column;\n      height:100%;\n    }\n\n    #sec4-amorphous-features .card h3{font-size:17px;margin:0 0 8px;color:#0F172A;}\n    #sec4-amorphous-features .card .tag{\n      display:inline-flex;\n      padding:3px 10px;\n      border-radius:999px;\n      font-size:11px;\n      letter-spacing:.12em;\n      text-transform:uppercase;\n      background:#0F172A;\n      color:#E5E7EB;\n      margin-bottom:12px;\n    }\n\n    #sec4-amorphous-features .card p{font-size:14px;color:#374151;line-height:1.8;margin:0 0 10px;}\n    #sec4-amorphous-features .card ul{list-style:none;padding:0;margin:6px 0 0;font-size:14px;color:#4B5563;}\n    #sec4-amorphous-features .card li{\n      position:relative;\n      padding-left:16px;\n      margin-bottom:6px;\n      line-height:1.7;\n    }\n    #sec4-amorphous-features .card li::before{\n      content:\"\";\n      position:absolute;\n      left:0;\n      top:8px;\n      width:6px;\n      height:6px;\n      border-radius:999px;\n      background:#38BDF8;\n    }\n\n    @media(max-width:1000px){\n      #sec4-amorphous-features .grid{grid-template-columns:repeat(2,minmax(0,1fr));}\n    }\n    @media(max-width:690px){\n      #sec4-amorphous-features .features-shell{padding:0 18px;}\n      #sec4-amorphous-features .grid{grid-template-columns:1fr;}\n      #sec4-amorphous-features h2{font-size:24px;}\n    }\n  <\/style>\n\n  <div class=\"features-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Engineered for Energy Savings<\/div>\n      <h2>Key Features of XBRELE Amorphous Alloy Transformer Series<\/h2>\n      <p>\n        XBRELE <strong>amorphous alloy transformer<\/strong> solutions combine SBH15-M oil-immersed and SCBH15 dry-type\n        designs, delivering a <strong>low loss transformer<\/strong> platform for modern 6\u201311&nbsp;kV distribution networks.\n        By replacing conventional silicon steel cores with an <strong>amorphous core transformer<\/strong> design, utilities\n        and industrial users gain a <strong>high efficiency distribution transformer<\/strong> that cuts no-load loss and\n        reduces lifetime OPEX. For a broader view of matching oil-immersed and dry-type products, please visit the\n        <a href=\"https:\/\/xbrele.com\/power-distribution-transformers\/\" style=\"color:#2563EB;text-decoration:none;\">\n          Power Distribution Transformers pillar page\n        <\/a>.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n\n      <!-- Card 1 -->\n      <article class=\"card\">\n        <span class=\"tag\">Core &amp; Losses<\/span>\n        <h3>Ultra-Low Core Loss with Amorphous Alloy<\/h3>\n        <p>\n          The core of each <strong>amorphous alloy transformer<\/strong> is made from thin amorphous metal strips with very\n          low hysteresis and eddy current loss, improving efficiency compared with traditional silicon steel designs.\n        <\/p>\n        <ul>\n          <li><strong>Reduced no-load loss:<\/strong> Typical savings of 60\u201370% versus a comparable silicon steel transformer in continuous service.<\/li>\n          <li><strong>Lower operating temperature:<\/strong> Less core loss means less heat and longer insulation life for both SBH15-M and SCBH15 units.<\/li>\n          <li><strong>Stable magnetic performance:<\/strong> Optimised flux density keeps the <strong>amorphous core transformer<\/strong> within safe limits under voltage variation.<\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 2 -->\n      <article class=\"card\">\n        <span class=\"tag\">Energy Efficiency<\/span>\n        <h3>High Efficiency Distribution Transformer for Green Projects<\/h3>\n        <p>\n          As an <strong>energy efficient transformer<\/strong>, the XBRELE amorphous alloy distribution range is designed for\n          projects where energy saving and carbon reduction are core targets, from new substations to retrofit programs.\n        <\/p>\n        <ul>\n          <li><strong>Lower lifetime kWh consumption:<\/strong> Continuous no-load loss reduction directly cuts electricity bills and CO\u2082 emissions.<\/li>\n          <li><strong>Supports policy incentives:<\/strong> Many regions encourage the use of <strong>high efficiency distribution transformer<\/strong> technology in public tenders.<\/li>\n          <li>\n            <strong>Aligned with efficiency guidelines:<\/strong> Design principles reference resources from the\n            <a href=\"https:\/\/www.energy.gov\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#2563EB;text-decoration:none;\">\n              U.S. Department of Energy\n            <\/a> and similar agencies for transformer efficiency improvement.\n          <\/li>\n        <\/ul>\n      <\/article>\n\n      <!-- Card 3 -->\n      <article class=\"card\">\n        <span class=\"tag\">Reliability<\/span>\n        <h3>Robust Construction for Long-Term Operation<\/h3>\n        <p>\n          Both SBH15-M oil-immersed and SCBH15 dry-type <strong>amorphous alloy transformer<\/strong> designs use reinforced\n          winding structures and proven insulation systems to ensure long-term reliability in distribution networks.\n        <\/p>\n        <ul>\n          <li><strong>Strong short-circuit withstand:<\/strong> Optimised coil clamping and mechanical bracing protect the windings during fault events.<\/li>\n          <li><strong>Consistent dielectric performance:<\/strong> Oil-immersed and dry-type designs are coordinated to meet IEC and utility requirements.<\/li>\n          <li><strong>Flexible configurations:<\/strong> XBRELE can customise tap ranges, vector groups and accessories to match specific <strong>amorphous alloy distribution transformer<\/strong> projects.<\/li>\n        <\/ul>\n      <\/article>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-793ba61\" data-block-id=\"793ba61\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-793ba61-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-f763d8a\" data-v=\"4\" data-block-id=\"f763d8a\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-f763d8a-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-f763d8a-inner-blocks\">\n<section id=\"sec5-amorphous-quality\" style=\"background:#0B1220;padding:72px 0 78px;color:#E5E7EB;\">\n  <style>\n    #sec5-amorphous-quality{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;}\n    #sec5-amorphous-quality .quality-shell{max-width:1500px;margin:0 auto;padding:0 5vw;}\n    #sec5-amorphous-quality .sec-header{max-width:820px;margin:0 auto 32px;text-align:center;}\n    #sec5-amorphous-quality .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec5-amorphous-quality h2{font-size:26px;margin:0 0 8px;color:#F9FAFB;}\n    #sec5-amorphous-quality .sec-header p{margin:0;font-size:14px;color:#CBD5F5;line-height:1.7;}\n    #sec5-amorphous-quality .grid{display:grid;grid-template-columns:minmax(0,1.2fr) minmax(0,1.05fr);gap:28px;align-items:flex-start;}\n\n    \/* \u5de6\u4fa7\u5de5\u827a\u6d41\u7a0b\u5361\u7247 *\/\n    #sec5-amorphous-quality .process-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:radial-gradient(circle at top left,rgba(56,189,248,.14) 0,rgba(15,23,42,.98) 36%,#020617 100%);\n      padding:22px 22px 24px;\n      box-shadow:0 22px 52px rgba(15,23,42,.9);\n    }\n    #sec5-amorphous-quality .process-card h3{font-size:17px;margin:0 0 8px;color:#E5F0FF;}\n    #sec5-amorphous-quality .process-card p{font-size:13.5px;color:#CBD5F5;line-height:1.75;margin:0 0 14px;}\n    #sec5-amorphous-quality .step-list{list-style:none;margin:0;padding:0;display:flex;flex-direction:column;gap:10px;}\n    #sec5-amorphous-quality .step{display:grid;grid-template-columns:auto minmax(0,1fr);gap:8px 12px;align-items:flex-start;}\n    #sec5-amorphous-quality .step-badge{\n      width:24px;height:24px;border-radius:999px;\n      border:1px solid rgba(148,163,184,.7);\n      display:flex;align-items:center;justify-content:center;\n      font-size:11px;font-weight:600;color:#E5E7EB;\n      background:rgba(15,23,42,.85);\n      flex-shrink:0;\n    }\n    #sec5-amorphous-quality .step h4{font-size:13.5px;margin:1px 0 3px;color:#F9FAFB;}\n    #sec5-amorphous-quality .step p{font-size:12.5px;margin:0;color:#CBD5F5;line-height:1.7;}\n\n    \/* \u53f3\u4fa7 QA \u6807\u51c6\u5361\u7247 *\/\n    #sec5-amorphous-quality .qa-card{\n      border-radius:22px;\n      border:1px solid rgba(148,163,184,.35);\n      background:rgba(15,23,42,.96);\n      padding:20px 20px 22px;\n      box-shadow:0 22px 52px rgba(15,23,42,.8);\n      border-top:3px solid #38BDF8;\n    }\n    #sec5-amorphous-quality .qa-label{font-size:11px;letter-spacing:.14em;text-transform:uppercase;color:#93C5FD;margin-bottom:3px;}\n    #sec5-amorphous-quality .qa-card h3{font-size:15px;margin:0 0 4px;color:#E5F0FF;}\n    #sec5-amorphous-quality .qa-card p{font-size:13px;color:#CBD5F5;margin:0 0 4px;line-height:1.65;}\n    #sec5-amorphous-quality .qa-block{margin-top:10px;padding-top:10px;border-top:1px solid rgba(148,163,184,.35);}\n    #sec5-amorphous-quality .qa-block:first-of-type{margin-top:6px;padding-top:0;border-top:none;}\n    #sec5-amorphous-quality .qa-block h4{font-size:13.5px;margin:0 0 3px;color:#E5F0FF;}\n    #sec5-amorphous-quality .qa-block ul{list-style:none;padding:0;margin:0;font-size:12.5px;color:#E5E7EB;}\n    #sec5-amorphous-quality .qa-block li{position:relative;padding-left:12px;margin-bottom:2px;line-height:1.6;}\n    #sec5-amorphous-quality .qa-block li::before{\n      content:\"\";position:absolute;left:0;top:7px;\n      width:5px;height:5px;border-radius:999px;background:#38BDF8;\n    }\n    #sec5-amorphous-quality .qa-note{font-size:12px;color:#9CA3AF;margin-top:4px;}\n\n    @media(max-width:1000px){#sec5-amorphous-quality .grid{grid-template-columns:1fr;}}\n    @media(max-width:690px){\n      #sec5-amorphous-quality .quality-shell{padding:0 18px;}\n      #sec5-amorphous-quality h2{font-size:22px;}\n    }\n  <\/style>\n\n  <div class=\"quality-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Quality Control<\/div>\n      <h2>Manufacturing &amp; Testing of Amorphous Alloy Transformer Series<\/h2>\n      <p>\n        XBRELE combines controlled core processing, precise coil winding and strict type\/routine tests to ensure\n        that SBH15-M oil-immersed and SCBH15 dry-type units operate reliably as low loss, energy-efficient\n        distribution transformers in 6\u201311&nbsp;kV networks.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <!-- \u5de5\u827a\u6d41\u7a0b\uff08\u5de6\u4fa7\uff09 -->\n      <article class=\"process-card\">\n        <h3>Core &amp; Winding Manufacturing Process<\/h3>\n        <p>\n          The production line for amorphous-core distribution transformers focuses on stable magnetic performance,\n          low no-load loss and long-term mechanical strength, from strip cutting and annealing to final tank assembly.\n        <\/p>\n\n        <ul class=\"step-list\">\n\n          <li class=\"step\">\n            <div class=\"step-badge\">01<\/div>\n            <div>\n              <h4>Amorphous Core Strip Handling<\/h4>\n              <p>Amorphous metal strips are cut and stacked under controlled tension, with annealing and banding to minimise stress and vibration in service.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">02<\/div>\n            <div>\n              <h4>LV Foil &amp; HV Layer Winding<\/h4>\n              <p>Low-voltage foil coils and high-voltage multi-layer windings are wound with precise tension control to provide strong short-circuit withstand capability.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">03<\/div>\n            <div>\n              <h4>Vacuum Drying &amp; Oil Filling (SBH15-M)<\/h4>\n              <p>For SBH15-M, assembled cores and coils are vacuum-dried and filled with transformer oil to improve insulation resistance and moisture protection.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">04<\/div>\n            <div>\n              <h4>Resin Casting of HV Coils (SCBH15)<\/h4>\n              <p>SCBH15 dry-type designs use vacuum resin casting or encapsulation of HV windings to achieve low partial discharge and stable dielectric strength.<\/p>\n            <\/div>\n          <\/li>\n\n          <li class=\"step\">\n            <div class=\"step-badge\">05<\/div>\n            <div>\n              <h4>Final Assembly &amp; Functional Checks<\/h4>\n              <p>Tank welding, terminal installation, tap changer operation and accessories are verified before final inspection and shipment.<\/p>\n            <\/div>\n          <\/li>\n\n        <\/ul>\n      <\/article>\n\n      <!-- \u8d28\u91cf\u6807\u51c6\uff08\u53f3\u4fa7\uff09 -->\n      <section class=\"qa-card\">\n        <div class=\"qa-section\">\n          <div class=\"qa-label\">QA Standards<\/div>\n          <h3>Routine &amp; Type Tests<\/h3>\n          <p>\n            Tests are performed according to IEC 60076 series and corresponding national standards, covering both\n            oil-immersed SBH15-M and SCBH15 dry-type designs for distribution service.\n          <\/p>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Electrical Performance<\/h4>\n          <ul>\n            <li>Ratio, polarity and vector group verification for all tapping positions.<\/li>\n            <li>Measurement of load loss and impedance at reference temperature.<\/li>\n            <li>No-load loss confirmation to ensure the unit meets the specified low-loss level.<\/li>\n            <li>Applied and induced voltage tests on HV and LV windings.<\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Insulation &amp; Dielectric Strength<\/h4>\n          <ul>\n            <li>Insulation resistance and tan&nbsp;\u03b4 checks on coils and core\/coil assemblies.<\/li>\n            <li>Partial discharge measurements on SCBH15 dry-type windings to keep PD within specified limits.<\/li>\n            <li>\n              Dielectric design references guidance from\n              <a href=\"https:\/\/webstore.iec.ch\/publication\/223\" target=\"_blank\" rel=\"noopener\" style=\"color:#93C5FD;text-decoration:none;\">\n                IEC&nbsp;60076-1\n              <\/a>\n              for power transformer insulation coordination.\n            <\/li>\n          <\/ul>\n        <\/div>\n\n        <div class=\"qa-block\">\n          <h4>Mechanical &amp; Visual Inspection<\/h4>\n          <ul>\n            <li>Verification of short-circuit withstand strength and clamping structure.<\/li>\n            <li>Inspection of tank welding, surface treatment and nameplate information.<\/li>\n            <li>Check of fittings, protection devices and options required in distribution transformer projects.<\/li>\n          <\/ul>\n          <div class=\"qa-note\">\n            For large utility or EPC contracts, XBRELE can provide detailed test reports and documentation,\n            together with references to related products on the\n            <a href=\"https:\/\/xbrele.com\/power-distribution-transformers\/\" style=\"color:#93C5FD;text-decoration:none;\">\n              Power Distribution Transformers pillar page\n            <\/a>.\n          <\/div>\n        <\/div>\n      <\/section>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-c23a9a5\" data-block-id=\"c23a9a5\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-c23a9a5-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-fd95870\" data-v=\"4\" data-block-id=\"fd95870\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-fd95870-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-fd95870-inner-blocks\">\n<section id=\"sec4-lv-features\" style=\"background:#ffffff;padding:90px 0 100px;\">\n  <style>\n    \/* \u6837\u5f0f\u4fdd\u6301\u4e0e LCZ \u9875\u9762\u5b8c\u5168\u4e00\u81f4 *\/\n    #sec4-lv-features{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n    #sec4-lv-features .features-shell{max-width:1600px;margin:0 auto;padding:0 5vw;}\n    #sec4-lv-features .sec-header{max-width:820px;margin:0 auto 40px;text-align:center;}\n    #sec4-lv-features .kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;color:#38BDF8;margin-bottom:8px;}\n    #sec4-lv-features h2{font-size:28px;margin:0 0 10px;color:#0F172A;}\n    #sec4-lv-features .sec-header p{margin:0;font-size:15px;color:#4B5563;line-height:1.8;}\n    #sec4-lv-features .grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:24px;margin-top:40px;}\n    #sec4-lv-features .card{border-radius:20px;border:1px solid #E5E7EB;background:#F9FAFB;padding:22px 22px 24px;box-shadow:0 14px 32px rgba(15,23,42,.04);display:flex;flex-direction:column;height:100%;}\n    #sec4-lv-features .card h3{font-size:17px;margin:0 0 8px;color:#0F172A;}\n    #sec4-lv-features .card .tag{display:inline-flex;align-items:center;justify-content:flex-start;padding:3px 10px;border-radius:999px;font-size:11px;letter-spacing:.12em;text-transform:uppercase;background:#0F172A;color:#E5E7EB;margin-bottom:12px;}\n    #sec4-lv-features .card p{font-size:14px;color:#4B5563;line-height:1.8;margin:0 0 10px;color:#374151;}\n    #sec4-lv-features .card ul{list-style:none;padding:0;margin:6px 0 0;font-size:14px;color:#4B5563;}\n    #sec4-lv-features .card li{position:relative;padding-left:16px;margin-bottom:6px;line-height:1.7;}\n    #sec4-lv-features .card li::before{content:\"\";position:absolute;left:0;top:8px;width:6px;height:6px;border-radius:999px;background:#38BDF8;}\n    @media(max-width:1000px){#sec4-lv-features .grid{grid-template-columns:repeat(2,minmax(0,1fr));}}\n    @media(max-width:690px){#sec4-lv-features .features-shell{padding:0 18px;}#sec4-lv-features .grid{grid-template-columns:1fr;}#sec4-lv-features h2{font-size:24px;}}\n  <\/style>\n\n  <div class=\"features-shell\">\n    <div class=\"sec-header\">\n      <div class=\"kicker\">Designed for Resilience<\/div>\n      <h2>Features for Mining &amp; Harsh Environments<\/h2>\n      <p>\n        From the dusty depths of mines to humid industrial plants, XBRELE&#8217;s specialized contactors are built to endure conditions where standard equipment fails.\n      <\/p>\n    <\/div>\n\n    <div class=\"grid\">\n      <article class=\"card\">\n        <span class=\"tag\">Solid Technology<\/span>\n        <h3>Embedded Pole (LZNJ)<\/h3>\n        <p>\n          The LZNJ series uses epoxy resin to completely encapsulate the vacuum interrupter, isolating it from the external environment.\n        <\/p>\n        <ul>\n          <li><strong>Pollution Proof:<\/strong> Fully protected against dust, humidity, and condensation.<\/li>\n          <li><strong>Shock Resistant:<\/strong> Rigid structure absorbs external mechanical impact and vibration.<\/li>\n          <li><strong>Maintenance Free:<\/strong> No cleaning of insulators required over the operational lifespan.<\/li>\n        <\/ul>\n      <\/article>\n\n      <article class=\"card\">\n        <span class=\"tag\">Mining Ready<\/span>\n        <h3>1.14kV Mining Capability (CKJ)<\/h3>\n        <p>\n          Specifically rated for 1140V networks, bridging the gap between standard LV (690V) and MV (3.3kV) for underground equipment.\n        <\/p>\n        <ul>\n          <li><strong>Heavy Duty AC-4:<\/strong> Capable of frequent inching and plugging operations common in mining conveyors.<\/li>\n          <li><strong>Compact Size:<\/strong> Designed to fit into space-constrained mining flameproof enclosures.<\/li>\n          <li><strong>Safe Switching:<\/strong> No exposed arc, ideal for potentially explosive environments.<\/li>\n        <\/ul>\n      <\/article>\n\n      <article class=\"card\">\n        <span class=\"tag\">High Power<\/span>\n        <h3>High Current Handling (LCZ3)<\/h3>\n        <p>\n          For massive industrial motors and drives, we offer specialized solutions handling up to 3200A at 2kV voltage levels.\n        <\/p>\n        <ul>\n          <li><strong>3200A Rating:<\/strong> Supports large-scale industrial pumps, fans, and steel mill drives.<\/li>\n          <li><strong>Robust Mechanism:<\/strong> Enhanced drive system to manage high contact pressure and prevent welding.<\/li>\n          <li><strong>2kV Insulation:<\/strong> Higher voltage margin than standard 1140V units for industrial grids.<\/li>\n        <\/ul>\n      <\/article>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-0191f2e\" data-block-id=\"0191f2e\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-0191f2e-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-0031c96\" data-v=\"4\" data-block-id=\"0031c96\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-0031c96-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-0031c96-inner-blocks\">\n<section id=\"sec7-amorphous-faq\" style=\"padding:80px 0 100px;background:#ffffff;\">\n  <style>\n    #sec7-amorphous-faq{font-family:system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Arial,sans-serif;color:#0F172A;}\n\n    \/* Optimized container width *\/\n    #sec7-amorphous-faq .faq-shell{max-width:1200px;margin:0 auto;padding:0 5vw;}\n\n    #sec7-amorphous-faq .faq-header{max-width:900px;margin:0 auto 48px;text-align:center;}\n    #sec7-amorphous-faq .faq-kicker{text-transform:uppercase;letter-spacing:.16em;font-size:12px;font-weight:600;background:#F0F9FF;padding:4px 12px;border-radius:99px;color:#0284C7;margin-bottom:10px;display:inline-block;}\n    #sec7-amorphous-faq h2{font-size:30px;margin:0 0 14px;color:#0F172A;line-height:1.2;}\n    #sec7-amorphous-faq .faq-header p{margin:0 auto;font-size:16px;color:#4B5563;line-height:1.7;max-width:750px;}\n\n    \/* Grid Layout Optimization *\/\n    #sec7-amorphous-faq .faq-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:20px;align-items:flex-start;}\n\n    #sec7-amorphous-faq details{border-radius:12px;border:1px solid #E2E8F0;background:#FFFFFF;padding:20px 24px;transition:all .2s ease;box-shadow:0 2px 4px rgba(0,0,0,0.02);}\n    #sec7-amorphous-faq details:hover{border-color:#CBD5E1;box-shadow:0 4px 12px rgba(0,0,0,0.04);}\n    #sec7-amorphous-faq details[open]{background:#F8FAFC;border-color:#CBD5E1;}\n\n    #sec7-amorphous-faq summary{list-style:none;cursor:pointer;font-size:16px;font-weight:600;color:#1E293B;display:flex;justify-content:space-between;align-items:center;line-height:1.5;}\n    #sec7-amorphous-faq summary::-webkit-details-marker{display:none;}\n\n    #sec7-amorphous-faq .faq-icon{flex-shrink:0;width:24px;height:24px;border-radius:99px;background:#F1F5F9;color:#64748B;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:bold;margin-left:12px;}\n    #sec7-amorphous-faq details[open] .faq-icon{background:#2563EB;color:#FFFFFF;transform:rotate(45deg);}\n\n    #sec7-amorphous-faq .faq-answer{margin-top:12px;font-size:15px;color:#475569;line-height:1.75;}\n\n    @media(max-width:690px){\n      #sec7-amorphous-faq .faq-grid{grid-template-columns:1fr;}\n      #sec7-amorphous-faq h2{font-size:24px;}\n      #sec7-amorphous-faq details{padding:16px;}\n    }\n  <\/style>\n\n  <div class=\"faq-shell\">\n    <div class=\"faq-header\">\n      <div class=\"faq-kicker\">FAQ \u00b7 Amorphous Alloy Transformers<\/div>\n      <h2>Common Questions About Amorphous Alloy Transformers<\/h2>\n      <p>\n        Below are frequently asked questions on <strong>amorphous alloy transformers<\/strong>, including loss reduction,\n        typical applications, reliability and how they compare with conventional silicon steel distribution transformers.\n      <\/p>\n    <\/div>\n\n    <div class=\"faq-grid\">\n      \n      <!-- Q1 -->\n      <details open>\n        <summary>\n          <span>What is an amorphous alloy transformer?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          An amorphous alloy transformer uses a magnetic core made from thin amorphous metal strips instead of traditional\n          silicon steel laminations. The amorphous material has very low hysteresis and eddy current loss, so the unit\n          operates as a low-loss distribution transformer, especially under no-load or light-load conditions.\n        <\/div>\n      <\/details>\n\n      <!-- Q2 -->\n      <details>\n        <summary>\n          <span>How much energy can be saved compared with a silicon steel transformer?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          In many 10\/11&nbsp;kV distribution applications, replacing a conventional silicon steel transformer with an\n          amorphous core design can reduce no-load loss by roughly 60\u201370%, depending on rating and operating voltage.\n          Over a 20\u201330 year service life, this reduction in continuous core loss can translate into significant energy\n          savings and lower CO\u2082 emissions for utilities and industrial users.\n        <\/div>\n      <\/details>\n\n      <!-- Q3 -->\n      <details>\n        <summary>\n          <span>Where are SCBH15 and SBH15-M amorphous transformers typically used?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          SCBH15 dry-type units are commonly installed in indoor substations, commercial buildings and infrastructure\n          projects where fire-safety and low maintenance are important. SBH15-M oil-immersed designs are suitable for\n          outdoor distribution poles, pad-mounted substations and compact kiosks. Both are used on 6\u201311&nbsp;kV feeders\n          where long-term energy efficiency is a design target.\n        <\/div>\n      <\/details>\n\n      <!-- Q4 -->\n      <details>\n        <summary>\n          <span>Are amorphous transformers harder to install than standard distribution transformers?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Installation is similar to other distribution transformers of the same rating. For dry-type SCBH15, attention\n          should be paid to ventilation and clearance inside the substation room. For oil-immersed SBH15-M, foundations,\n          earthing and oil containment follow standard utility practice. XBRELE can provide drawings and basic guidelines\n          to support EPC contractors during installation and commissioning.\n        <\/div>\n      <\/details>\n\n      <!-- Q5 -->\n      <details>\n        <summary>\n          <span>Do amorphous core transformers require special maintenance?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Routine checks are similar to conventional transformers: inspecting terminations, monitoring temperature,\n          verifying protection settings and, for oil-immersed units, periodic oil testing. The amorphous core itself\n          does not need special handling once installed. Dry-type models mainly require cleaning of ventilation paths\n          and visual inspection of resin and terminals.\n        <\/div>\n      <\/details>\n\n      <!-- Q6 -->\n      <details>\n        <summary>\n          <span>Which standards apply to amorphous alloy distribution transformers?<\/span>\n          <span class=\"faq-icon\">+<\/span>\n        <\/summary>\n        <div class=\"faq-answer\">\n          Amorphous transformers are designed and tested under the same basic framework as other power transformers,\n          following standards such as <strong>IEC&nbsp;60076-1<\/strong> (general requirements) and related parts for\n          temperature rise, insulation coordination and short-circuit strength. For energy-efficiency policies and\n          reference values, many engineers also consult guidance from organisations like the\n          <a href=\"https:\/\/www.energy.gov\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#2563EB;text-decoration:underline;\">\n            U.S. Department of Energy\n          <\/a>.\n          For an overview of related product families, you can also review XBRELE\u2019s\n          <a href=\"https:\/\/xbrele.com\/power-distribution-transformers\/\" style=\"color:#2563EB;text-decoration:underline;\">\n            power distribution transformers\n          <\/a>\n          portfolio.\n        <\/div>\n      <\/details>\n\n    <\/div>\n  <\/div>\n<\/section>\n<\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Power Distribution Transformers Amorphous Alloy Transformer (SBH15-M \/ SCBH15 Series) XBRELE\u2019s amorphous alloy transformer series includes the SBH15-M oil-immersed range (5\u2013160&nbsp;kVA) and SCBH15 dry-type units (30\u20132500&nbsp;kVA). With significantly lower no-load loss compared to silicon steel transformers, these high-efficiency models are designed for 6\u201311&nbsp;kV distribution networks requiring energy savings and reduced OPEX. SBH15-M SCBH15 Low Loss [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1304,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1345","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"bottom","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=1345"}],"version-history":[{"count":9,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1345\/revisions"}],"predecessor-version":[{"id":2032,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1345\/revisions\/2032"}],"up":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1304"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=1345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}