{"id":1963,"date":"2025-12-04T13:53:51","date_gmt":"2025-12-04T13:53:51","guid":{"rendered":"https:\/\/xbrele.com\/?page_id=1963"},"modified":"2025-12-04T15:16:51","modified_gmt":"2025-12-04T15:16:51","slug":"vacuum-contactor-manufacturer","status":"publish","type":"page","link":"https:\/\/xbrele.com\/ru\/vacuum-contactor-manufacturer\/","title":{"rendered":"\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432"},"content":{"rendered":"<div class=\"wp-block-stackable-columns alignfull stk-block-columns stk-block stk-e0fd90d\" data-block-id=\"e0fd90d\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-e0fd90d-column alignfull\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-3f3b46e\" data-v=\"4\" data-block-id=\"3f3b46e\"><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-3f3b46e-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-3f3b46e-inner-blocks\">\n<style>\n    \/* --- XBRELE PRO STYLE SYSTEM (v5.1 - Contactor Edition) --- *\/\n    \n    .xbrele-pro-page {\n        font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        color: #111;\n        line-height: 1.7; \n        font-size: 18px; \n        font-weight: 400;\n        background-color: #fff;\n    }\n\n    .xbrele-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        padding: 0 20px;\n    }\n\n    .xbrele-section {\n        padding: 60px 0;\n        border-bottom: 1px solid #f0f0f0;\n    }\n    .xbrele-section.bg-light {\n        background-color: #f8fbfb;\n    }\n\n    .xbrele-pro-page h1 {\n        font-size: 42px;\n        font-weight: 800;\n        text-align: center;\n        margin-bottom: 30px;\n        color: #000;\n        letter-spacing: -0.5px;\n    }\n    \n    .xbrele-pro-page h2 {\n        font-size: 30px;\n        color: #000;\n        margin-top: 50px;\n        margin-bottom: 25px;\n        position: relative;\n        padding-left: 20px;\n        border-left: 8px solid #009688; \/* XBRELE Teal *\/\n        font-weight: 700;\n        text-transform: uppercase;\n    }\n    \n    .xbrele-pro-page h3 {\n        font-size: 22px;\n        font-weight: 700;\n        margin-top: 35px;\n        margin-bottom: 15px;\n        color: #009688;\n    }\n\n    .xbrele-pro-page p {\n        margin-bottom: 25px;\n        color: #222;\n        text-align: justify;\n    }\n\n    \/* Hero \u56fe\u7247\u6837\u5f0f *\/\n    .xbrele-hero-img {\n        width: 100%;\n        height: auto;\n        border-radius: 6px;\n        margin-bottom: 40px;\n        box-shadow: 0 4px 12px rgba(0,0,0,0.1);\n        display: block;\n    }\n\n    .xbrele-list {\n        list-style: none;\n        padding: 0;\n        margin-bottom: 30px;\n    }\n    .xbrele-list li {\n        position: relative;\n        padding-left: 30px;\n        margin-bottom: 12px;\n        color: #222;\n    }\n    .xbrele-list li::before {\n        content: \"\u25a0\";\n        position: absolute;\n        left: 0;\n        color: #009688;\n        font-size: 14px;\n        top: 6px;\n    }\n\n    .xbrele-tech-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 40px 0;\n        box-shadow: 0 5px 15px rgba(0,0,0,0.05);\n        font-size: 16px;\n    }\n    .xbrele-tech-table th, .xbrele-tech-table td {\n        padding: 18px;\n        border: 1px solid #ddd;\n    }\n    .xbrele-tech-table th {\n        background-color: #009688;\n        color: #fff;\n        font-weight: 700;\n        text-align: left;\n    }\n    .xbrele-tech-table tr:nth-child(even) {\n        background-color: #fcfcfc;\n    }\n\n    .xbrele-link {\n        color: #009688;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid rgba(0,150,136,0.2);\n        transition: all 0.2s;\n    }\n    .xbrele-link:hover {\n        background-color: rgba(0,150,136,0.1);\n        border-bottom-color: #009688;\n    }\n\n    .xbrele-ext-link {\n        color: #555;\n        text-decoration: underline;\n        font-style: italic;\n    }\n\n    .xbrele-cta-box {\n        background: linear-gradient(135deg, #009688 0%, #004d40 100%);\n        color: #fff;\n        padding: 60px;\n        border-radius: 8px;\n        text-align: center;\n        margin-top: 60px;\n    }\n    .xbrele-cta-btn {\n        display: inline-block;\n        background-color: #fff;\n        color: #009688 !important;\n        padding: 18px 45px;\n        font-weight: 800;\n        text-transform: uppercase;\n        border-radius: 4px;\n        text-decoration: none;\n        margin-top: 25px;\n        font-size: 18px;\n        box-shadow: 0 4px 6px rgba(0,0,0,0.2);\n    }\n    .xbrele-cta-btn:hover {\n        background-color: #f4f4f4;\n        transform: translateY(-2px);\n    }\n<\/style>\n\n<div class=\"xbrele-pro-page\">\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h1>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0438 OEM-\u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/h1>\n            \n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-contactor-factory-production-line.webp\" \n                 alt=\"\u0417\u0430\u0432\u043e\u0434-\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 XBRELE \u0434\u043b\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u0438 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432\" \n                 class=\"xbrele-hero-img\" \/>\n\n            <p>\n                \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u2014 \u044d\u0442\u043e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043e\u0431\u043b\u0430\u0441\u0442\u044c \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u043a\u0438, \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043d\u0430 \u0432\u044b\u043f\u0443\u0441\u043a \u0432\u044b\u0441\u043e\u043a\u043e\u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f. \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439, \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u043d\u044b\u0445 \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0440\u0435\u0434\u043a\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u00ab\u0440\u0430\u0431\u043e\u0447\u0438\u043c\u0438 \u043b\u043e\u0448\u0430\u0434\u043a\u0430\u043c\u0438\u00bb \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u043c\u0438 \u043d\u0430 \u0441\u043e\u0442\u043d\u0438 \u0442\u044b\u0441\u044f\u0447 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439. \u041a\u0430\u043a \u0432\u0435\u0434\u0443\u0449\u0438\u0439 <strong>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/strong>, XBRELE \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442 \u0448\u0438\u0440\u043e\u043a\u0438\u0439 \u0430\u0441\u0441\u043e\u0440\u0442\u0438\u043c\u0435\u043d\u0442 \u043d\u0438\u0437\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 (1,14 \u043a\u0412) \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 (7,2 \u043a\u0412 \u2013 40,5 \u043a\u0412) \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432. \u041d\u0430\u0448 \u0437\u0430\u0432\u043e\u0434 \u043e\u0431\u044a\u0435\u0434\u0438\u043d\u044f\u0435\u0442 \u043f\u0435\u0440\u0435\u0434\u043e\u0432\u044b\u0435 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0430 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c\u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439, \u043c\u0435\u0442\u0430\u043b\u043b\u0443\u0440\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438 \u0442\u044f\u0436\u0435\u043b\u043e\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u043f\u043e \u0432\u0441\u0435\u043c\u0443 \u043c\u0438\u0440\u0443.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u041f\u0440\u043e\u0446\u0435\u0441\u0441 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n            <p>\n                \u0412 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442\u043d\u044b\u043c\u0438 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c. \u0412 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043c\u043e\u0436\u0435\u0442 \u0441\u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c 10 000 \u0440\u0430\u0437, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043e\u043b\u0436\u0435\u043d \u043d\u0430\u0434\u0435\u0436\u043d\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0434\u043e <strong>1 000 000 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/strong>. \u042d\u0442\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0438\u043d\u043e\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0430 \u043a \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0443.\n            <\/p>\n            <p>\n                <strong>\u0421\u0431\u043e\u0440\u043a\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b:<\/strong> \u0421\u0435\u0440\u0434\u0446\u0435\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0435\u0433\u043e \u0441\u043e\u043b\u0435\u043d\u043e\u0438\u0434\u043d\u044b\u0439 \u043f\u0440\u0438\u0432\u043e\u0434. \u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f XBRELE \u0441\u0430\u043c\u043e\u0441\u0442\u043e\u044f\u0442\u0435\u043b\u044c\u043d\u043e \u0438\u0437\u0433\u043e\u0442\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043c\u0435\u0434\u043d\u044b\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0438 \u0441\u043e\u0431\u0438\u0440\u0430\u0435\u0442 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0435 \u044f\u0434\u0440\u0430 \u0438\u0437 \u043f\u0440\u0435\u0446\u0438\u0437\u0438\u043e\u043d\u043d\u044b\u0445 \u0448\u0442\u0430\u043c\u043f\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0434\u0435\u0442\u0430\u043b\u0435\u0439. \u041c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u0443\u044e \u0441\u0445\u0435\u043c\u0443 \u201c\u0434\u0432\u043e\u0439\u043d\u043e\u0439 \u043a\u0430\u0442\u0443\u0448\u043a\u0438\u201d \u0438\u043b\u0438 \u201c\u0428\u0418\u041c-\u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f\u201d, \u0447\u0442\u043e\u0431\u044b \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0443\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u0438 \u0441\u043d\u0438\u0437\u0438\u0442\u044c \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u0438 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u0435.\n            <\/p>\n            <p>\n                <strong>\u0412\u044b\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u043d\u0438\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f:<\/strong> \u0414\u043b\u044f <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/jcz-vacuum-contactor\/\" class=\"xbrele-link\">\u0421\u0435\u0440\u0438\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 JCZ<\/a>, \u043e\u0447\u0435\u043d\u044c \u0432\u0430\u0436\u043d\u043e \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u0432\u044b\u0440\u043e\u0432\u043d\u044f\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c. \u041c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043f\u0440\u0438\u0441\u043f\u043e\u0441\u043e\u0431\u043b\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0437\u0430\u0437\u043e\u0440\u0430 \u043c\u0435\u0436\u0434\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c\u0438 \u0438 \u043f\u0435\u0440\u0435\u0431\u0435\u0433\u0430 \u0441 \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c\u044e \u0434\u043e 0,1 \u043c\u043c. \u0422\u0430\u043a\u0430\u044f \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u0435\u0442 \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0442\u0440\u0435\u0445 \u0444\u0430\u0437, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044f \u201c\u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u043e\u0441\u0442\u044c\u201d, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0432\u0435\u0441\u0442\u0438 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438.\n            <\/p>\n            <p>\n                <strong>\u0424\u043e\u0440\u043c\u043e\u0432\u0430\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0440\u0430\u043c\u044b:<\/strong> \u0414\u043b\u044f \u043d\u0430\u0448\u0438\u0445 \u0441\u0435\u0440\u0438\u0439 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441 \u0442\u0432\u0435\u0440\u0434\u043e\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0435\u0439 \u043c\u044b \u0444\u043e\u0440\u043c\u0443\u0435\u043c \u0440\u0430\u043c\u044b \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0432\u044b\u0441\u043e\u043a\u043e\u043f\u0440\u043e\u0447\u043d\u043e\u0433\u043e DMC (\u0442\u0435\u0441\u0442\u043e\u043e\u0431\u0440\u0430\u0437\u043d\u043e\u0433\u043e \u0444\u043e\u0440\u043c\u043e\u0432\u043e\u0447\u043d\u043e\u0433\u043e \u043a\u043e\u043c\u043f\u0430\u0443\u043d\u0434\u0430) \u0438\u043b\u0438 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u043e\u0439 \u0441\u043c\u043e\u043b\u044b. \u042d\u0442\u0430 \u043f\u0440\u043e\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u043b\u043e\u043c\u043a\u0438, \u0432\u044b\u0437\u0432\u0430\u043d\u043d\u044b\u0435 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0435\u0439, \u0447\u0442\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043e\u0431\u0449\u0438\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0434\u043b\u044f \u043f\u043e\u0434\u0437\u0435\u043c\u043d\u043e\u0433\u043e \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0421\u044b\u0440\u044c\u0435, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u043e\u0435 \u0432 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n            <p>\n                \u0414\u043b\u044f \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u0434\u043e 1200 \u0440\u0430\u0437 \u0432 \u0447\u0430\u0441) \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0435 \u0432 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u0445, \u0434\u043e\u043b\u0436\u043d\u044b \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u044d\u043a\u0441\u0442\u0440\u0435\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438. XBRELE \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u0442 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0438\u0445 \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u0438.\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b (WCu \u043f\u0440\u043e\u0442\u0438\u0432 CuCr):<\/strong> \u0412\u043d\u0443\u0442\u0440\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u0431\u0443\u0442\u044b\u043b\u043a\u0438 \u043c\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u043c \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u0435 \u0441\u043f\u043b\u0430\u0432\u044b \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438. \u0414\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u043c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0441 \u043d\u0438\u0437\u043a\u0438\u043c \u0443\u0440\u043e\u0432\u043d\u0435\u043c \u0441\u043a\u0430\u0447\u043a\u0430 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0447\u0442\u043e\u0431\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u044b\u0435 \u0443\u0434\u0430\u0440\u044b. \u0414\u043b\u044f \u0437\u0430\u043f\u0443\u0441\u043a\u0430 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439 (\u0440\u0435\u0436\u0438\u043c AC-4) \u043c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c \u043f\u0440\u043e\u0447\u043d\u044b\u0435 \u0441\u043f\u043b\u0430\u0432\u044b \u0432\u043e\u043b\u044c\u0444\u0440\u0430\u043c\u0430 \u0438 \u043c\u0435\u0434\u0438 (WCu) \u0438\u043b\u0438 CuCr, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b \u043a \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u044d\u0440\u043e\u0437\u0438\u0438.<\/li>\n                <li><strong>\u042d\u043c\u0430\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043c\u0435\u0434\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u043a\u0430:<\/strong> \u0412 \u043d\u0430\u0448\u0438\u0445 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0445 \u043a\u0430\u0442\u0443\u0448\u043a\u0430\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u044d\u043c\u0430\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043c\u0435\u0434\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u043a\u0430 \u043a\u043b\u0430\u0441\u0441\u0430 H (180 \u00b0C), \u0447\u0442\u043e \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u0435\u0442 \u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0430 \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430.<\/li>\n                <li><strong>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b:<\/strong> \u0414\u043b\u044f <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/low-voltage-vacuum-contactor-solid-series\/\" class=\"xbrele-link\">\u0421\u0435\u0440\u0438\u044f \u0441 \u0442\u0432\u0435\u0440\u0434\u044b\u043c \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u043c \u043f\u043e\u043b\u044e\u0441\u043e\u043c (LZNJ)<\/a>, \u041c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c \u0433\u0438\u0434\u0440\u043e\u0444\u043e\u0431\u043d\u0443\u044e \u0446\u0438\u043a\u043b\u043e\u0430\u043b\u0438\u0444\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0443\u044e \u0441\u043c\u043e\u043b\u0443, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043f\u0440\u0435\u0432\u043e\u0441\u0445\u043e\u0434\u043d\u0443\u044e \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0442\u0440\u0435\u043a\u0438\u043d\u0433\u0443 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043d\u0430\u0440\u0443\u0436\u043d\u043e\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438\u043b\u0438 \u0432\u043b\u0430\u0436\u043d\u043e\u0439 \u0441\u0440\u0435\u0434\u044b.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/h2>\n            <p>\n                \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u0432\u044b\u0441\u043e\u043a\u043e\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0441\u0431\u043e\u0440\u043a\u0438 \u0438 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f. \u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f XBRELE \u0438\u043d\u0432\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043b\u0430 \u0432 \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u0443\u044e \u043b\u0438\u043d\u0438\u044e, \u0447\u0442\u043e\u0431\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430.\n            <\/p>\n            <p>\n                <strong>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043d\u0430\u043c\u043e\u0442\u043e\u0447\u043d\u044b\u0435 \u043c\u0430\u0448\u0438\u043d\u044b:<\/strong> \u0427\u0442\u043e\u0431\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432 \u043a\u0430\u0436\u0434\u043e\u0439 \u043f\u0430\u0440\u0442\u0438\u0438, \u043d\u0430\u0448\u0438 \u0441\u043e\u043b\u0435\u043d\u043e\u0438\u0434\u043d\u044b\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u043d\u0430\u043c\u043e\u0442\u0430\u043d\u044b \u043d\u0430 \u0432\u044b\u0441\u043e\u043a\u043e\u0441\u043a\u043e\u0440\u043e\u0441\u0442\u043d\u044b\u0445 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0430\u043c\u043e\u0442\u043e\u0447\u043d\u044b\u0445 \u043c\u0430\u0448\u0438\u043d\u0430\u0445 \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u043d\u0430\u0442\u044f\u0436\u0435\u043d\u0438\u044f.\n            <\/p>\n            <p>\n                <strong>\u0418\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u0435\u043d\u0434\u044b \u0434\u043b\u044f \u043e\u0431\u043a\u0430\u0442\u043a\u0438:<\/strong> \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0442\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u044e \u0441\u0440\u0430\u0437\u0443 \u043f\u043e\u0441\u043b\u0435 \u0441\u0431\u043e\u0440\u043a\u0438, XBRELE \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0441\u0442\u0435\u043d\u0434\u044b \u0434\u043b\u044f \u201c\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u043a\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f\u201d. \u041a\u0430\u0436\u0434\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043f\u0440\u043e\u0445\u043e\u0434\u0438\u0442 \u0431\u043e\u043b\u0435\u0435 300 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043b\u044f \u0443\u043f\u043b\u043e\u0442\u043d\u0435\u043d\u0438\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u0440\u0443\u0436\u0438\u043d \u0438 \u0437\u0430\u0449\u0435\u043b\u043e\u043a \u043f\u0435\u0440\u0435\u0434 \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u043a\u043e\u0439.\n            <\/p>\n            <p>\n                <strong>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u043f\u0430\u0439\u043a\u0430 (\u0432\u043d\u0435\u0448\u043d\u0438\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c):<\/strong> \u041c\u044b \u0437\u0430\u043a\u0443\u043f\u0430\u0435\u043c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0431\u0443\u0442\u044b\u043b\u043a\u0438 \u0443 \u0432\u0435\u0434\u0443\u0449\u0438\u0445 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u043e\u0432, \u043d\u043e \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c \u0441\u0442\u0440\u043e\u0433\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u043b\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0433\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430, \u0447\u0442\u043e\u0431\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u043f\u0430\u0439\u043a\u0438 \u0438 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u0430 \u043a\u0430\u0436\u0434\u043e\u0439 \u043f\u0430\u0440\u0442\u0438\u0438 \u043f\u0435\u0440\u0435\u0434 \u0442\u0435\u043c, \u043a\u0430\u043a \u043e\u043d\u0430 \u043f\u043e\u0441\u0442\u0443\u043f\u0430\u0435\u0442 \u043d\u0430 \u043d\u0430\u0448\u0443 \u0441\u0431\u043e\u0440\u043e\u0447\u043d\u0443\u044e \u043b\u0438\u043d\u0438\u044e.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n            <p>\n                \u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441\u043e\u0441\u0440\u0435\u0434\u043e\u0442\u043e\u0447\u0435\u043d\u044b \u043d\u0430 \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u0438 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438 \u0447\u0430\u0441\u0442\u043e\u043c \u0446\u0438\u043a\u043b\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438. XBRELE \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u0435 \u043c\u0435\u0440\u044b \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432 IEC 60470 \u0438 GB\/T 14808.\n            <\/p>\n            \n            <table class=\"xbrele-tech-table\">\n                <tr>\n                    <th>\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u0442\u0435\u0441\u0442\u0430<\/th>\n                    <th>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439 \/ \u041b\u0438\u043c\u0438\u0442<\/th>\n                    <th>\u0426\u0435\u043b\u044c<\/th>\n                <\/tr>\n                <tr>\n                    <td><strong>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/strong><\/td>\n                    <td>85% \u2013 110% \u041d\u0430\u0441<\/td>\n                    <td>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u043f\u0430\u0434\u0435\u043d\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0441\u0435\u0442\u0438<\/strong><\/td>\n                    <td>32 \u043a\u0412 \/ 42 \u043a\u0412 (\u0434\u043b\u044f 7,2\/12 \u043a\u0412)<\/td>\n                    <td>\u041f\u0440\u043e\u0432\u0435\u0440\u044f\u0435\u0442 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043c\u0435\u0436\u0434\u0443 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0435\u043d\u043d\u044b\u043c\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c\u0438 \u0438 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435\u043c.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0446\u0435\u043f\u0438<\/strong><\/td>\n                    <td>&lt; 60\u201380 \u043c\u043a\u041e\u043c<\/td>\n                    <td>\u041f\u0440\u043e\u0432\u0435\u0440\u044f\u0435\u0442 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0433\u043e \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432\u0430.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u0422\u0435\u0441\u0442 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438<\/strong><\/td>\n                    <td>\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u043d\u0435\u0435 2 \u043c\u0441<\/td>\n                    <td>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0432\u0441\u0435\u0445 \u0442\u0440\u0435\u0445 \u0444\u0430\u0437.<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0441\u0442\u0435\u043f\u0435\u043d\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u0430<\/strong><\/td>\n                    <td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0438\u0441\u043a\u0440\u043e\u0439 \/ \u041c\u0430\u0433\u043d\u0435\u0442\u0440\u043e\u043d<\/td>\n                    <td>\u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u0431\u0443\u0442\u044b\u043b\u043a\u0430 \u043d\u0435 \u043f\u0440\u043e\u0442\u0435\u043a\u043b\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0441\u0431\u043e\u0440\u043a\u0438.<\/td>\n                <\/tr>\n            <\/table>\n            \n            <p>\n                \u0414\u043b\u044f \u043d\u0430\u0448\u0438\u0445 \u043c\u043e\u0434\u0435\u043b\u0435\u0439 \u0441 \u201c\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u0435\u0439\u201d (\u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0445 \u0432 \u0441\u043b\u0443\u0447\u0430\u044f\u0445, \u043a\u043e\u0433\u0434\u0430 \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0443\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u0434\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c \u043d\u0443\u043b\u0435\u0432\u044b\u043c) \u043c\u044b \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u043c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u0438, \u0447\u0442\u043e\u0431\u044b \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c, \u0447\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u0437\u0430\u043a\u0440\u044b\u0442\u044b\u043c \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0441\u0438\u043b\u044c\u043d\u043e\u0439 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u041f\u043e\u0447\u0435\u043c\u0443 \u0432\u0430\u043c \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0441 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0437\u0430\u043a\u0430\u0437<\/h2>\n            <p>\n                \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0442\u043e\u0432\u0430\u0440\u0430\u043c\u0438 \u0442\u0438\u043f\u0430 \u201c\u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0438 \u0438 \u0440\u0430\u0431\u043e\u0442\u0430\u0439\u201d; \u043e\u043d\u0438 \u0447\u0430\u0441\u0442\u043e \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442\u044c \u043a \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u043c \u0441\u0442\u0430\u0440\u044b\u043c \u043f\u0443\u0441\u043a\u0430\u0442\u0435\u043b\u044f\u043c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439 \u0438\u043b\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c, \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0438\u0439 \u043f\u043e \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u043e\u043c\u0443 \u0437\u0430\u043a\u0430\u0437\u0443, \u0442\u0430\u043a\u043e\u0439 \u043a\u0430\u043a XBRELE, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0430\u0434\u0430\u043f\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u043a \u0432\u0430\u0448\u0438\u043c \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044f\u043c.\n            <\/p>\n            <p>\n                \u041c\u044b \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u043c \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u0443\u044e \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0443 \u0432 <strong>\u0422\u0438\u043f \u0434\u0435\u0440\u0436\u0430\u0442\u0435\u043b\u044f<\/strong>. \u041c\u044b \u043c\u043e\u0436\u0435\u043c \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u044c <strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0449\u0430\u044f \u0441\u0438\u043b\u0430<\/strong> \u0442\u0438\u043f\u044b (\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435) \u0438\u043b\u0438 <strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u044f<\/strong> \u0442\u0438\u043f\u044b (\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0437\u0430\u043a\u0440\u044b\u0442\u044b\u043c\u0438 \u0431\u0435\u0437 \u043f\u0438\u0442\u0430\u043d\u0438\u044f, \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u043d\u0435\u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439).\n            <\/p>\n            <p>\n                \u0414\u043b\u044f \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u043c\u044b \u0430\u0434\u0430\u043f\u0442\u0438\u0440\u0443\u0435\u043c <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/low-voltage-vacuum-contactor-solid-series\/\" class=\"xbrele-link\">\u0421\u0435\u0440\u0438\u044f CKJ (1,14 \u043a\u0412)<\/a> \u0441 \u0443\u0441\u0438\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0440\u0430\u043c\u0430\u043c\u0438 \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\u043c\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a 36 \u0412, 127 \u0412), \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0431\u044b\u0447\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432 \u043f\u043e\u0434\u0437\u0435\u043c\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445. \u041c\u044b \u0442\u0430\u043a\u0436\u0435 \u043c\u043e\u0436\u0435\u043c \u0441\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043a\u043b\u0435\u043c\u043c \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c\u0438 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f\u043c\u0438 \u0448\u0438\u043d, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442 \u0432\u0430\u043c \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044e.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0438\u043c\u0435\u044e\u0442 \u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u043e\u043f\u044b\u0442<\/h2>\n            <p>\n                \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0433\u043b\u0443\u0431\u043e\u043a\u0438\u0445 \u0437\u043d\u0430\u043d\u0438\u0439 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u201c\u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0439 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f\u201d (AC-3, AC-4). \u0418\u043d\u0436\u0435\u043d\u0435\u0440\u044b XBRELE \u043f\u043e\u043d\u0438\u043c\u0430\u044e\u0442, \u0447\u0442\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f (\u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430) \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438 \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442\u0441\u044f \u043e\u0442 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 (\u0435\u043c\u043a\u043e\u0441\u0442\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430).\n            <\/p>\n            <p>\n                \u041d\u0430\u0448 \u043e\u043f\u044b\u0442 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u0435\u0442, \u0447\u0442\u043e \u043c\u044b \u043f\u043e\u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c \u0432\u0430\u043c \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u0439 \u043f\u0440\u043e\u0434\u0443\u043a\u0442. \u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0441 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u043c\u044b \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c \u043d\u0430\u0448 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/ckg-vacuum-contactor\/\" class=\"xbrele-link\">\u0421\u0435\u0440\u0438\u044f CKG<\/a> \u043e\u0441\u043d\u0430\u0449\u0435\u043d\u044b \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430\u043c\u0438 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0432\u0441\u0442\u0430\u0432\u043a\u0438 \u0438\u043b\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c\u0438 \u0431\u0443\u0442\u044b\u043b\u043a\u0430\u043c\u0438, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u043c\u0438 \u043d\u0430 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0435 \u0442\u043e\u043a\u0438 \u0438 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 (TRV), \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u043c\u0438 \u0431\u0430\u0442\u0430\u0440\u0435\u044f\u043c\u0438.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u042d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/h2>\n            <p>\n                \u0411\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u043f\u0440\u044f\u043c\u044b\u043c \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0430\u043c \u043e\u0442 XBRELE \u0432 \u041a\u0438\u0442\u0430\u0435, \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0435 OEM-\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0438 \u0434\u0438\u0441\u0442\u0440\u0438\u0431\u044c\u044e\u0442\u043e\u0440\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u044e\u0442 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u043d\u043e\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e. \u041c\u044b \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u043c \u0441\u043e\u043b\u0435\u043d\u043e\u0438\u0434\u043d\u044b\u0435 \u043f\u0440\u0438\u0432\u043e\u0434\u044b \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0440\u0430\u043c\u044b \u043d\u0430 \u0441\u043e\u0431\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435, \u0438\u0437\u0431\u0435\u0433\u0430\u044f \u043d\u0430\u0446\u0435\u043d\u043a\u0438 \u0441\u0431\u043e\u0440\u0449\u0438\u043a\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0437\u0430\u043a\u0443\u043f\u0430\u044e\u0442 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0443 \u0441\u0442\u043e\u0440\u043e\u043d\u043d\u0438\u0445 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u043e\u0432.\n            <\/p>\n            <p>\n                \u041d\u0430\u0448 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/low-voltage-vacuum-contactor-solid-series\/\" class=\"xbrele-link\">\u041d\u0438\u0437\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b (1140 \u0412)<\/a> \u0448\u0438\u0440\u043e\u043a\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u044b \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0438\u0445 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438. \u041e\u043d\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0432 10 \u0440\u0430\u0437 \u0431\u043e\u043b\u044c\u0448\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043f\u0440\u0438 \u0441\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u0438\u043c\u043e\u0439 \u0446\u0435\u043d\u0435, \u0447\u0442\u043e \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u0443\u044e \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u043b\u0430\u0434\u0435\u043d\u0438\u044f (TCO) \u0434\u043b\u044f \u043a\u043e\u043d\u0435\u0447\u043d\u044b\u0445 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 \u0446\u0435\u043c\u0435\u043d\u0442\u043d\u044b\u0445 \u0437\u0430\u0432\u043e\u0434\u0430\u0445, \u0441\u0442\u0430\u043b\u0435\u043b\u0438\u0442\u0435\u0439\u043d\u044b\u0445 \u0437\u0430\u0432\u043e\u0434\u0430\u0445 \u0438 \u0448\u0430\u0445\u0442\u0430\u0445.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u0410\u0434\u0430\u043f\u0442\u0438\u0440\u0443\u0435\u043c\u044b\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438<\/h2>\n            <p>\n                \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043b\u0438\u043d\u0438\u0438 XBRELE \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u044b \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u0438. \u041c\u044b \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u043c \u043a\u0430\u043a \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 <strong>3-\u043f\u043e\u043b\u044e\u0441\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/strong> (JCZ5) \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 <strong>\u041e\u0434\u043d\u043e\u043f\u043e\u043b\u044e\u0441\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/strong> (JCZ1), \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0439 \u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0432\u043e\u0437\u0430\u0445 \u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0438\u043d\u0434\u0443\u043a\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u0433\u0440\u0435\u0432\u0430.\n            <\/p>\n            <p>\n                \u041d\u0430\u0448\u0430 \u0430\u0434\u0430\u043f\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u044f\u0435\u0442\u0441\u044f \u0438 \u043d\u0430 \u0441\u0442\u0438\u043b\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438. \u041c\u044b \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u043c \u0441\u0442\u0430\u0446\u0438\u043e\u043d\u0430\u0440\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0434\u043b\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 \u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0442\u0438\u043f\u0430 \u0440\u0443\u0447\u043d\u043e\u0439 \u0442\u0435\u043b\u0435\u0436\u043a\u0438, \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b\u0435 \u0441 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e\u043c KYN28, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0438 \u0438\u0437\u0432\u043b\u0435\u043a\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0442\u0430\u043a \u0436\u0435, \u043a\u0430\u043a \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c. \u042d\u0442\u0430 \u0433\u0438\u0431\u043a\u043e\u0441\u0442\u044c \u0434\u0435\u043b\u0430\u0435\u0442 XBRELE \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043f\u0430\u0440\u0442\u043d\u0435\u0440\u043e\u043c \u0434\u043b\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043f\u0430\u043d\u0435\u043b\u0435\u0439, \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0438\u0445 \u0441 \u0440\u0430\u0437\u043d\u043e\u043e\u0431\u0440\u0430\u0437\u043d\u044b\u043c\u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u043d\u044b\u043c\u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0435 \u043c\u0435\u0442\u043e\u0434\u044b \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430<\/h2>\n            <p>\n                \u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e \u0441\u0432\u043e\u0435\u0439 \u0441\u0443\u0442\u0438 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u043c\u0438. \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0445 \u0438\u043b\u0438 SF6-\u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u043d\u0435 \u0432\u044b\u0434\u0435\u043b\u044f\u0435\u0442 \u043f\u0430\u0440\u043d\u0438\u043a\u043e\u0432\u044b\u0445 \u0433\u0430\u0437\u043e\u0432 \u0438 \u043d\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f. XBRELE \u0438\u0434\u0435\u0442 \u0435\u0449\u0435 \u0434\u0430\u043b\u044c\u0448\u0435, \u043e\u043f\u0442\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u044f \u043d\u0430\u0448\u0438 \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f.\n            <\/p>\n            <p>\n                \u041d\u0430\u0448\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u043d\u044b\u0435 \u043c\u043e\u0434\u0443\u043b\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0448\u0438\u0440\u043e\u0442\u043d\u043e-\u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u0443\u044e \u043c\u043e\u0434\u0443\u043b\u044f\u0446\u0438\u044e (\u0428\u0418\u041c) \u0438\u043b\u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0431\u0435\u0440\u0435\u0433\u0430\u044e\u0449\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043d\u0438\u0436\u0430\u044e\u0442 \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0449\u0443\u044e \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0434\u043e 90% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u043c\u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0430\u043c\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u042d\u0442\u043e \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0443\u0433\u043b\u0435\u0440\u043e\u0434\u043d\u044b\u0439 \u0441\u043b\u0435\u0434 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438, \u043d\u043e \u0438 \u0443\u043c\u0435\u043d\u044c\u0448\u0430\u0435\u0442 \u0442\u0435\u043f\u043b\u043e\u0432\u0443\u044e \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u0432\u043d\u0443\u0442\u0440\u0438 \u0448\u043a\u0430\u0444\u0430 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u044f \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section\">\n        <div class=\"xbrele-container\">\n            <h2>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432 \u041a\u0438\u0442\u0430\u0435<\/h2>\n            <p>\n                \u041a\u0438\u0442\u0430\u0439 \u043b\u0438\u0434\u0438\u0440\u0443\u0435\u0442 \u0432 \u043c\u0438\u0440\u0435 \u043f\u043e \u043e\u0431\u044a\u0435\u043c\u0443 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439. XBRELE \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0440\u0430\u0437\u0432\u0438\u0442\u0443\u044e \u0446\u0435\u043f\u043e\u0447\u043a\u0443 \u043f\u043e\u0441\u0442\u0430\u0432\u043e\u043a \u0432 \u0412\u044d\u043d\u044c\u0447\u0436\u043e\u0443, \u0447\u0442\u043e\u0431\u044b \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0438\u0442\u044c:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u0411\u044b\u0441\u0442\u0440\u043e\u0435 \u043f\u0440\u043e\u0442\u043e\u0442\u0438\u043f\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435:<\/strong> \u041c\u044b \u043c\u043e\u0436\u0435\u043c \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u044b\u0435 \u043f\u043b\u0430\u0441\u0442\u0438\u043d\u044b \u0438\u043b\u0438 \u0430\u0434\u0430\u043f\u0442\u0435\u0440\u044b \u0434\u043b\u044f \u0448\u0438\u043d \u043c\u0435\u043d\u0435\u0435 \u0447\u0435\u043c \u0437\u0430 10 \u0434\u043d\u0435\u0439.<\/li>\n                <li><strong>\u0420\u0430\u0437\u043d\u043e\u043e\u0431\u0440\u0430\u0437\u043d\u044b\u0439 \u0430\u0441\u0441\u043e\u0440\u0442\u0438\u043c\u0435\u043d\u0442:<\/strong> \u041c\u044b \u043f\u043e\u043a\u0440\u044b\u0432\u0430\u0435\u043c \u0432\u0435\u0441\u044c \u0441\u043f\u0435\u043a\u0442\u0440 \u043e\u0442 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f 80 \u0410 \u0434\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f 630 \u0410.<\/li>\n                <li><strong>\u0418\u043d\u0436\u0438\u043d\u0438\u0440\u0438\u043d\u0433 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438:<\/strong> \u041f\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u0432\u044b\u0441\u043e\u043a\u043e\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c IEC, \u043f\u043e \u0446\u0435\u043d\u0435, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u0435\u0441\u043a\u0438 \u0446\u0435\u043b\u0435\u0441\u043e\u043e\u0431\u0440\u0430\u0437\u043d\u043e\u0439 \u0434\u043b\u044f \u0440\u0430\u0437\u0432\u0438\u0432\u0430\u044e\u0449\u0438\u0445\u0441\u044f \u0440\u044b\u043d\u043a\u043e\u0432.<\/li>\n            <\/ul>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-section bg-light\">\n        <div class=\"xbrele-container\">\n            <h2>\u041f\u043e\u0438\u0441\u043a \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n            <p>\n                \u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043f\u0430\u0440\u0442\u043d\u0435\u0440\u0430 \u043d\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0439\u0442\u0435\u0441\u044c \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u043e\u043c. \u0423\u0447\u0442\u0438\u0442\u0435 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0435:\n            <\/p>\n            <ul class=\"xbrele-list\">\n                <li><strong>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u0446\u0438\u043a\u043b\u0430:<\/strong> \u041e\u0446\u0435\u043d\u0438\u0432\u0430\u0435\u0442 \u043b\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u044b \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 AC-4 (\u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u0435\/\u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435)?<\/li>\n                <li><strong>\u041d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u043a\u0430\u0442\u0443\u0448\u043a\u0438:<\/strong> \u041f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u044e\u0442 \u043b\u0438 \u043e\u043d\u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0441 \u0448\u0438\u0440\u043e\u043a\u0438\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u044b\u0435 110\u2013220 \u0412)?<\/li>\n                <li><strong>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f:<\/strong> \u041f\u0440\u043e\u0434\u0443\u043a\u0442\u044b \u043f\u0440\u043e\u0448\u043b\u0438 \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0432 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u044f\u0445?<\/li>\n                <li><strong>\u0417\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u0447\u0430\u0441\u0442\u0438:<\/strong> \u041c\u043e\u0433\u0443\u0442 \u043b\u0438 \u043e\u043d\u0438 \u043f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0431\u0443\u0442\u044b\u043b\u043a\u0438 \u0438 \u0437\u043c\u0435\u0435\u0432\u0438\u043a\u0438?<\/li>\n            <\/ul>\n            <p>\n                XBRELE \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u043f\u0440\u043e\u0437\u0440\u0430\u0447\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0434\u0430\u043d\u043d\u044b\u0435 \u0438 \u043f\u043e\u043b\u043d\u0443\u044e \u043f\u043e\u0441\u043b\u0435\u043f\u0440\u043e\u0434\u0430\u0436\u043d\u0443\u044e \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0443, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u0446\u0435\u043d\u0442\u0440\u043e\u0432 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438.\n            <\/p>\n        <\/div>\n    <\/div>\n\n    <div class=\"xbrele-container\">\n        <div class=\"xbrele-cta-box\">\n            <h2>\u0413\u043e\u0442\u043e\u0432\u044b \u0437\u0430\u043a\u0443\u043f\u0430\u0442\u044c \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u044e \u0443 \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f?<\/h2>\n            <p>\u041f\u0435\u0440\u0435\u0441\u0442\u0430\u043d\u044c\u0442\u0435 \u043f\u043b\u0430\u0442\u0438\u0442\u044c \u043c\u0430\u0440\u0436\u0443 \u0442\u0440\u0435\u0439\u0434\u0435\u0440\u0430\u043c. \u0421\u0432\u044f\u0436\u0438\u0442\u0435\u0441\u044c \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u0441 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u043e\u0439 \u043a\u043e\u043c\u0430\u043d\u0434\u043e\u0439 XBRELE, \u0447\u0442\u043e\u0431\u044b \u043e\u0431\u0441\u0443\u0434\u0438\u0442\u044c \u0432\u0430\u0448\u0438 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u0445.<\/p>\n            <a href=\"https:\/\/xbrele.com\/ru\/contact\/\" class=\"xbrele-cta-btn\">\u041f\u043e\u043b\u0443\u0447\u0438\u0442\u0435 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u043e\u0435 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum Contactor Manufacturer &#038; OEM Solutions Vacuum Contactor manufacturing is a specialized field within electrical engineering focused on producing high-endurance switching devices for frequent operation applications. Unlike circuit breakers, which are designed for rare fault protection, Vacuum Contactors are the workhorses of the industry, engineered to switch motors, transformers, and capacitor banks hundreds of thousands [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1963","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled","vertical_spacing_source":"custom","content_area_spacing":"top","styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":6}},"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1963","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=1963"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1963\/revisions"}],"predecessor-version":[{"id":1997,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/pages\/1963\/revisions\/1997"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=1963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}