{"id":1537,"date":"2025-11-29T16:51:39","date_gmt":"2025-11-29T16:51:39","guid":{"rendered":"https:\/\/xbrele.com\/difference-between-vcb-and-contactor-in-electrical-systems\/"},"modified":"2026-04-07T15:12:19","modified_gmt":"2026-04-07T15:12:19","slug":"difference-between-vcb-and-contactor-in-electrical-systems","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/difference-between-vcb-and-contactor-in-electrical-systems\/","title":{"rendered":"\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 vcb \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e.webp\" alt=\"\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 vcb \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c\" class=\"wp-image-1535\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/546c8f89923e416ab3a2a249aeb1a75e-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0418\u0441\u0442\u043e\u0447\u043d\u0438\u043a \u0438\u0437\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">pexels<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u0427\u0430\u0441\u0442\u043e \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u043d\u0438\u043c\u0430\u0442\u044c \u0440\u0430\u0437\u043d\u0438\u0446\u0443 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c, \u0447\u0442\u043e\u0431\u044b \u0441\u0434\u0435\u043b\u0430\u0442\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0439 \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB) \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u0446\u0435\u043f\u0438 \u0438 \u0431\u044b\u0441\u0442\u0440\u043e \u0433\u0430\u0441\u0438\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0434\u0443\u0433\u0438, \u0447\u0442\u043e \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0446\u0435\u043f\u044f\u043c\u0438 \u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0447\u0430\u0441\u0442\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u044c\u0441\u044f, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0435\u0433\u043e \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u043c \u0434\u043b\u044f \u043f\u043e\u0432\u0441\u0435\u0434\u043d\u0435\u0432\u043d\u043e\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438. \u0412\u044b\u0431\u043e\u0440 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u0440\u0430\u0441\u0442\u0440\u0430\u0442\u044b \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432, \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>VCB \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u0441\u043d\u0438\u0436\u0430\u044f \u0438\u0437\u043d\u043e\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u044f \u0441\u0440\u043e\u043a \u0435\u0433\u043e \u0441\u043b\u0443\u0436\u0431\u044b.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0449\u0438\u0442\u043e\u0432.<\/p><\/li>\n\n\n\n<li><p>\u041c\u0438\u0440\u043e\u0432\u043e\u0439 \u0440\u044b\u043d\u043e\u043a \u044d\u0442\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0440\u0430\u0441\u0442\u0435\u0442, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u0410\u0437\u0438\u0430\u0442\u0441\u043a\u043e-\u0422\u0438\u0445\u043e\u043e\u043a\u0435\u0430\u043d\u0441\u043a\u043e\u043c \u0440\u0435\u0433\u0438\u043e\u043d\u0435, \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0431\u044b\u0441\u0442\u0440\u043e\u0439 \u0438\u043d\u0434\u0443\u0441\u0442\u0440\u0438\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u041a\u043b\u044e\u0447\u0435\u0432\u044b\u0435 \u0432\u044b\u0432\u043e\u0434\u044b<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>VCB \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044f \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430\u0445.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0446\u0435\u043f\u044f\u043c\u0438, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044f \u0447\u0430\u0441\u0442\u043e \u0432\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p><\/li>\n\n\n\n<li><p>\u0412\u044b\u0431\u0438\u0440\u0430\u0439\u0442\u0435 VCB \u0434\u043b\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439; \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u043e\u0431\u044b\u0447\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/p><\/li>\n\n\n\n<li><p>VCB \u043e\u0431\u043b\u0430\u0434\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0435\u0439 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c\u044e, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u043f\u0440\u0438\u0433\u043e\u0434\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u0440\u0430\u0431\u043e\u0442\u044b, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a VCB \u0438\u043c\u0435\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f\u043c\u0438.<\/p><\/li>\n\n\n\n<li><p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0439 \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043f\u043e\u0432\u044b\u0441\u0438\u0432 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p><\/li>\n\n\n\n<li><p>\u0414\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0432\u0441\u0435\u0433\u0434\u0430 \u043f\u043e\u0434\u0431\u0438\u0440\u0430\u0439\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044f\u043c\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0432 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438.<\/p><\/li>\n\n\n\n<li><p>\u0420\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438\u043c\u0435\u0435\u0442 \u0440\u0435\u0448\u0430\u044e\u0449\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435; VCB \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043a\u0430\u0436\u0434\u044b\u0435 1\u20133 \u0433\u043e\u0434\u0430, \u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u044b\u0445 \u043f\u0440\u043e\u0432\u0435\u0440\u043e\u043a.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"difference-between-vcb-and-contactor\">\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"VCU \u0438 VCB \u2014 \u0420\u0410\u0417\u041b\u0418\u0427\u0418\u042f: \u0420\u0410\u0417\u041b\u0418\u0427\u0418\u0415 \u041c\u0415\u0416\u0414\u0423 \u2014 \u0412\u0410\u041a\u0423\u0423\u041c\u041d\u042b\u041c \u041a\u041e\u041d\u0422\u0410\u041a\u0422\u041e\u0420\u041e\u041c \u0418 \u0412\u0410\u041a\u0423\u0423\u041c\u041d\u042b\u041c \u0412\u042b\u041a\u041b\u042e\u0427\u0410\u0422\u0415\u041b\u0415\u041c\" width=\"1290\" height=\"968\" src=\"https:\/\/www.youtube.com\/embed\/mwd5eFAfCXA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-definition\">\u041e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 VCB<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u0438\u043b\u0438 VCB, \u2014 \u044d\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439. \u041e\u043d\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0435\u0442 \u043f\u043e\u0442\u043e\u043a \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u043f\u0440\u0438 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0438 \u0442\u0430\u043a\u0438\u0445 \u043f\u0440\u043e\u0431\u043b\u0435\u043c, \u043a\u0430\u043a \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u0438\u043b\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435. VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u0430\u043a\u0443\u0443\u043c \u0434\u043b\u044f \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043e\u0431\u0440\u0430\u0437\u0443\u0435\u0442\u0441\u044f \u043f\u0440\u0438 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u0446\u0435\u043f\u0438. \u042d\u0442\u0430 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u0435.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"main-function\">\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u044f<\/h4>\n\n\n\n<p>\u0412\u044b \u043f\u043e\u043b\u0430\u0433\u0430\u0435\u0442\u0435\u0441\u044c \u043d\u0430 VCB, \u0447\u0442\u043e\u0431\u044b \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043f\u043e\u0442\u043e\u043a \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u0432 \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0441\u0438\u0442\u0443\u0430\u0446\u0438\u044f\u0445. \u0415\u0433\u043e \u043e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u044f \u0437\u0430\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u0432 \u0437\u0430\u0449\u0438\u0442\u0435 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043f\u0443\u0442\u0435\u043c \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0446\u0435\u043f\u0438 \u043f\u0440\u0438 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438. \u042d\u0442\u043e \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u0434\u0440\u0443\u0433\u0438\u0445 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"protection-role\">\u0420\u043e\u043b\u044c \u0437\u0430\u0449\u0438\u0442\u044b<\/h4>\n\n\n\n<p>VCB \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442 \u043a\u0430\u043a \u0449\u0438\u0442 \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0435\u0442\u0438. \u041e\u043d \u0438\u0437\u043e\u043b\u0438\u0440\u0443\u0435\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u044b\u0435 \u0443\u0447\u0430\u0441\u0442\u043a\u0438 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u044f\u0442\u044c VCB \u0432 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441\u043e \u0441\u0440\u0435\u0434\u043d\u0438\u043c\u0438 \u0438 \u0432\u044b\u0441\u043e\u043a\u0438\u043c\u0438 \u0443\u0440\u043e\u0432\u043d\u044f\u043c\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043e\u0431\u044b\u0447\u043d\u043e \u043e\u0442 1 \u043a\u0412 \u0434\u043e 38 \u043a\u0412. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0435\u0433\u043e \u043a\u043b\u044e\u0447\u0435\u0432\u043e\u0439 \u0447\u0430\u0441\u0442\u044c\u044e \u0441\u0438\u0441\u0442\u0435\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"contactor-definition\">\u041e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430<\/h3>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u2014 \u044d\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0442\u043e\u043a\u043e\u043c \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u0432 \u0446\u0435\u043f\u0438. \u041e\u043d \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u0443\u0442\u0435\u043c \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u0430. \u041a\u043e\u0433\u0434\u0430 \u0432\u044b \u043f\u043e\u0434\u0430\u0435\u0442\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043d\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0443, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0437\u0430\u043c\u044b\u043a\u0430\u044e\u0442\u0441\u044f, \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043f\u043e\u0441\u0442\u0443\u043f\u0430\u0435\u0442 \u043a \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435, \u0442\u0430\u043a\u043e\u0439 \u043a\u0430\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044c \u0438\u043b\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f. \u041a\u043e\u0433\u0434\u0430 \u0432\u044b \u0441\u043d\u0438\u043c\u0430\u0435\u0442\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0441 \u043a\u0430\u0442\u0443\u0448\u043a\u0438, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u044e\u0442\u0441\u044f, \u043e\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u044f \u0442\u043e\u043a.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"main-function\">\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u044f<\/h4>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0446\u0435\u043f\u0435\u0439. \u042d\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0448\u0438\u0440\u043e\u043a\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438. \u041e\u043d\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0438\u043c\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c\u0438, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u043a\u043e\u0433\u0434\u0430 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"actuator-role\">\u0420\u043e\u043b\u044c \u043f\u0440\u0438\u0432\u043e\u0434\u0430<\/h4>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442 \u043a\u0430\u043a \u043f\u0440\u0438\u0432\u043e\u0434 \u0432 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u041e\u043d \u0440\u0435\u0430\u0433\u0438\u0440\u0443\u0435\u0442 \u043d\u0430 \u0441\u0438\u0433\u043d\u0430\u043b\u044b \u043e\u0442 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u0442 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u043c\u0430\u0448\u0438\u043d\u044b \u0438\u043b\u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435. \u042d\u0442\u0430 \u0444\u0443\u043d\u043a\u0446\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u0430\u0448\u0443 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044f \u043f\u0440\u044f\u043c\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u043c\u0438 \u0446\u0435\u043f\u044f\u043c\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"key-distinctions\">\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043e\u0442\u043b\u0438\u0447\u0438\u044f<\/h3>\n\n\n\n<p>\u0427\u0442\u043e\u0431\u044b \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0433\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u043d\u0438\u043c\u0430\u0442\u044c \u0440\u0430\u0437\u043d\u0438\u0446\u0443 \u043c\u0435\u0436\u0434\u0443 vcb \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c. \u0412\u043e\u0442 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043e\u0442\u043b\u0438\u0447\u0438\u044f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>VCB \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0432\u0430\u0448\u0443 \u0441\u0438\u0441\u0442\u0435\u043c\u0443, \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044f \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u0442 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a.<\/p><\/li>\n\n\n\n<li><p>\u041e\u0431\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043c\u043e\u0433\u0443\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0443\u044e \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044e, \u043d\u043e \u0438\u0445 \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u043e. VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u2014 \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0431\u043e\u0442\u043e\u0439.<\/p><\/li>\n\n\n\n<li><p>VCB \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0441\u043e \u0441\u0440\u0435\u0434\u043d\u0438\u043c \u0438 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u0443\u044e\u0442 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u043e\u0431\u044b\u0442\u0438\u0439. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0441 \u043d\u0438\u0437\u043a\u0438\u043c \u0438 \u0441\u0440\u0435\u0434\u043d\u0438\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u044e\u0442 \u0447\u0430\u0441\u0442\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0412\u0441\u0435\u0433\u0434\u0430 \u043f\u043e\u0434\u0431\u0438\u0440\u0430\u0439\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044f\u043c\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u0447\u0442\u043e\u0431\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c.<\/p>\n<\/blockquote>\n\n\n\n<p>\u041d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u0430 \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u0432 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0443\u043a\u0430\u0437\u0430\u043d\u044b \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0440\u043e\u043b\u0438 \u0438 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u044b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f\u0438\u0447\u043d\u0430\u044f \u0440\u043e\u043b\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0442\u0430 \u0438 \u043b\u043e\u043a\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0440\u0435\u0434\u043d\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 (\u043e\u0442 1 \u043a\u0412 \u0434\u043e 38 \u043a\u0412)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u0435\u043c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0448\u0438\u0440\u043e\u043a\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u044e\u0442\u0441\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0437\u0434\u0430\u043d\u0438\u0439 \u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435.<\/p>\n\n\n\n<p>\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u0442\u0430\u043a\u0436\u0435 \u043f\u0440\u043e\u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0432 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0434\u0443\u0433\u0438. VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0434\u043b\u044f \u0431\u043e\u043b\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u043c\u0438 \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u044b \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u043d\u043e \u043e\u0442\u043b\u0438\u0447\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0431\u043e\u043b\u0435\u0435 \u043f\u0440\u043e\u0441\u0442\u043e\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 VCB \u0434\u043b\u044f \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u044b\u0445, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u044b\u0445 \u0446\u0438\u043a\u043b\u043e\u0432 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f-\u0432\u044b\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u0440\u0430\u0437\u043d\u0438\u0446\u044b \u043c\u0435\u0436\u0434\u0443 vcb \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u043f\u0440\u0438\u043d\u0438\u043c\u0430\u0442\u044c \u043e\u0431\u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f, \u0437\u0430\u0449\u0438\u0449\u0430\u0442\u044c \u0441\u0432\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"operation-and-performance\">\u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"switching-frequency\">\u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/h3>\n\n\n\n<p>\u0412\u0430\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u0447\u0430\u0441\u0442\u043e\u0442\u0443 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043a\u043e\u0433\u0434\u0430 \u0432\u044b <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043c\u0435\u0436\u0434\u0443 VCB<\/a> \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440. \u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u043a\u0430\u043a \u0447\u0430\u0441\u0442\u043e \u043c\u043e\u0436\u043d\u043e \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u0442\u044c \u0438 \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0431\u0435\u0437 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0445 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f. \u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0432\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438 \u0438\u043b\u0438 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435 \u043c\u043d\u043e\u0433\u043e \u0440\u0430\u0437 \u0432 \u0434\u0435\u043d\u044c. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0442\u044c \u0442\u044b\u0441\u044f\u0447\u0438 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0447\u0430\u0441. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u044b\u043c \u0440\u0435\u0448\u0435\u043d\u0438\u0435\u043c \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>VCB \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u043e-\u0434\u0440\u0443\u0433\u043e\u043c\u0443. VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043e\u0431\u044b\u0447\u043d\u043e \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0438\u043b\u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. VCB \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0447\u0430\u0441\u0442\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438. \u0415\u0441\u043b\u0438 \u0432\u044b \u043f\u043e\u043f\u044b\u0442\u0430\u0435\u0442\u0435\u0441\u044c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c VCB \u0434\u043b\u044f \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0431\u044b\u0441\u0442\u0440\u043e \u0438\u0437\u043d\u043e\u0441\u044f\u0442\u0441\u044f. VCB \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0442\u043e\u043b\u044c\u043a\u043e \u0432 \u0442\u0435\u0445 \u0441\u043b\u0443\u0447\u0430\u044f\u0445, \u043a\u043e\u0433\u0434\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u043f\u043e\u0434\u0430\u0447\u0443 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u0437\u0430\u0449\u0438\u0442\u0438\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0412\u044b\u0431\u0438\u0440\u0430\u0439\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 VCB \u0434\u043b\u044f \u0440\u0435\u0434\u043a\u0438\u0445, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0439.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"interrupting-capacity\">\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c<\/h3>\n\n\n\n<p>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442, \u043a\u0430\u043a\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u043c\u043e\u0436\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c. \u042d\u0442\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0437\u043d\u0430\u0442\u044c \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. VCB \u043e\u0431\u043b\u0430\u0434\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c\u044e. \u0415\u0433\u043e \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u0442\u043e\u043a\u043e\u0432 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u042d\u0442\u0430 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c \u0434\u0435\u043b\u0430\u0435\u0442 VCB \u0432\u0430\u0436\u043d\u044b\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e\u043c \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0438\u043c\u0435\u0435\u0442 \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u043c\u0435\u043d\u044c\u0448\u0443\u044e \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0443\u044e \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c. \u041d\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043a\u043e\u0432 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u041f\u0440\u0438 \u043f\u043e\u043f\u044b\u0442\u043a\u0435 \u044d\u0442\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0439\u0442\u0438 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u0438 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044e. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0430 \u043d\u0435 \u0434\u043b\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043a\u043e\u0432 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u042d\u0442\u043e \u043a\u043b\u044e\u0447\u0435\u0432\u043e\u0435 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c.<\/p>\n\n\n\n<p>\u0412\u043e\u0442 \u043f\u0440\u043e\u0441\u0442\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0441\u0440\u0430\u0432\u043d\u0438\u0442\u044c:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f\u0438\u0447\u043d\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>VCB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (\u0431\u0435\u0437 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"arc-interruption\">\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/h3>\n\n\n\n<p>\u041f\u0440\u0438 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u0446\u0435\u043f\u0438 \u043c\u0435\u0436\u0434\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c\u0438 \u043e\u0431\u0440\u0430\u0437\u0443\u0435\u0442\u0441\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0434\u0443\u0433\u0430. \u0414\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u044d\u0442\u0443 \u0434\u0443\u0433\u0443. \u0412 VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0434\u043b\u044f \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438. \u0412\u0430\u043a\u0443\u0443\u043c \u0443\u0434\u0430\u043b\u044f\u0435\u0442 \u0432\u043e\u0437\u0434\u0443\u0445, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0434\u0443\u0433\u0430 \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u0434\u043b\u0438\u0442\u044c\u0441\u044f \u0434\u043e\u043b\u0433\u043e. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 VCB \u043e\u0447\u0435\u043d\u044c \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433 \u0432 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445.<\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0442\u0430\u043a\u0436\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0435\u0442 \u0434\u0443\u0433\u0443, \u043d\u043e \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u0430\u043a\u0443\u0443\u043c. \u0411\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0434\u043b\u044f \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u0434\u0443\u0433\u0438. \u042d\u0442\u043e \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u0440\u0438 \u043d\u0438\u0437\u043a\u0438\u0445 \u0438 \u0441\u0440\u0435\u0434\u043d\u0438\u0445 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\u0445. \u041e\u0434\u043d\u0430\u043a\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u043c\u043e\u0433\u0443\u0442 \u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c\u0441\u044f \u0441 \u0441\u0438\u043b\u044c\u043d\u044b\u043c\u0438 \u0434\u0443\u0433\u0430\u043c\u0438, \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u044e\u0449\u0438\u043c\u0438 \u043f\u0440\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u0445. \u0412 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0442\u0443\u0430\u0446\u0438\u044f\u0445 \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0434\u0443\u0433\u0438 \u0432\u0441\u0435\u0433\u0434\u0430 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c VCB.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u041f\u043e\u043c\u043d\u0438\u0442\u0435: VCB \u043e\u0442\u043b\u0438\u0447\u043d\u043e \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435\u043c \u0434\u0443\u0433\u0438 \u043f\u0440\u0438 \u0441\u0431\u043e\u044f\u0445, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u043f\u043e\u0432\u0441\u0435\u0434\u043d\u0435\u0432\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0441 \u043c\u0435\u043d\u044c\u0448\u0435\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0435\u0439 \u0434\u0443\u0433\u0438.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"current-chop\">\u0422\u0435\u043a\u0443\u0449\u0438\u0439 \u0447\u043e\u043f<\/h3>\n\n\n\n<p>\u041f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f (VCB) \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0437\u0430\u043c\u0435\u0442\u0438\u0442\u044c \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u043e\u0435 \u044f\u0432\u043b\u0435\u043d\u0438\u0435, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u043e\u0435 \u201c\u043f\u0435\u0440\u0435\u0440\u044b\u0432\u043e\u043c \u0442\u043e\u043a\u0430\u201d. \u041f\u0435\u0440\u0435\u0440\u044b\u0432 \u0442\u043e\u043a\u0430 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442, \u043a\u043e\u0433\u0434\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0435\u0442 \u0442\u043e\u043a \u0434\u043e \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u043e\u043d \u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c \u043e\u0431\u0440\u0430\u0437\u043e\u043c \u0434\u043e\u0441\u0442\u0438\u0433\u043d\u0435\u0442 \u043d\u0443\u043b\u044f. \u042d\u0442\u043e\u0442 \u044d\u0444\u0444\u0435\u043a\u0442 \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u0447\u0430\u0449\u0435 \u0432\u0441\u0442\u0440\u0435\u0447\u0430\u0435\u0442\u0441\u044f \u0432 VCB, \u0447\u0435\u043c \u0432 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u0445. \u0424\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0438\u043c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0442\u043e\u043a \u0432 \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u043c\u0435\u043d\u044c\u0448\u0435\u043c \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0435. \u042d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0434\u0443\u0433\u0430 \u0432\u043d\u0443\u0442\u0440\u0438 VCB \u043c\u043e\u0436\u0435\u0442 \u0432\u043d\u0435\u0437\u0430\u043f\u043d\u043e \u043f\u0440\u0435\u043a\u0440\u0430\u0442\u0438\u0442\u044c\u0441\u044f, \u0434\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u0442\u043e\u043a \u0435\u0449\u0435 \u043d\u0435 \u0434\u043e\u0441\u0442\u0438\u0433 \u0441\u0432\u043e\u0435\u0433\u043e \u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0446\u0430.<\/p>\n\n\n\n<p>\u041f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 VCB \u0434\u0443\u0433\u043e\u0432\u043e\u0439 \u0441\u0442\u043e\u043b\u0431 \u0432\u043d\u0443\u0442\u0440\u0438 \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u043d\u0435\u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u044b\u043c. \u0422\u0430\u043a\u0438\u0435 \u0444\u0430\u043a\u0442\u043e\u0440\u044b, \u043a\u0430\u043a \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0430\u0440\u0430 \u0438 \u0441\u043f\u043e\u0441\u043e\u0431 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u0447\u0435\u0440\u0435\u0437 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b, \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u043c\u0443 \u0440\u0430\u0437\u0440\u044b\u0432\u0443 \u0434\u0443\u0433\u0438. \u042d\u0442\u043e \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u044b \u0438 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u042d\u0442\u0438 \u0432\u043d\u0435\u0437\u0430\u043f\u043d\u044b\u0435 \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043c\u043e\u0433\u0443\u0442 \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u0442\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043d\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e. \u041f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u044d\u0442\u043e\u0442 \u044d\u0444\u0444\u0435\u043a\u0442 \u043d\u0435 \u0442\u0430\u043a \u0437\u0430\u043c\u0435\u0442\u0435\u043d. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0442 \u0442\u043e\u043a \u0442\u0430\u043a\u0438\u043c \u0436\u0435 \u043e\u0431\u0440\u0430\u0437\u043e\u043c, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043e\u043d\u0438 \u0440\u0435\u0434\u043a\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0442 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0442\u043e\u043a\u0430 \u0438\u043b\u0438 \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0441 \u044d\u0442\u0438\u043c \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0442\u0430\u043a\u0436\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u0435 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435 \u0442\u043e\u043a\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0430\u043a\u0438\u0445 \u044f\u0432\u043b\u0435\u043d\u0438\u0439, \u043a\u0430\u043a \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0437\u0430\u0436\u0438\u0433\u0430\u043d\u0438\u0435 \u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0442\u043e\u043a\u0430. \u042d\u0442\u043e \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u043c \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0438\u0445 \u043e\u0441\u043e\u0431\u044b\u043c \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430\u043c. \u0421\u043b\u0435\u0434\u0443\u0435\u0442 \u0437\u043d\u0430\u0442\u044c, \u0447\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u043f\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u0438\u043d\u044b\u043c \u0440\u0435\u0430\u043a\u0446\u0438\u044f\u043c \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438. \u0415\u0441\u043b\u0438 \u0432\u044b \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442\u0435 \u0441 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0438\u043b\u0438 \u0434\u043b\u0438\u043d\u043d\u044b\u043c\u0438 \u043a\u0430\u0431\u0435\u043b\u044f\u043c\u0438, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u0440\u0438\u0441\u043a \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0442\u043e\u043a\u0430.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0422\u0435\u043a\u0443\u0449\u0438\u0439 \u0442\u043e\u043a \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u043f\u0440\u0438\u0447\u0438\u043d\u043e\u0439, \u043f\u043e \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u0442\u044c \u0442\u0438\u043f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u043e\u0439. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 VCB \u0432 \u043d\u0435\u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u043c \u043c\u0435\u0441\u0442\u0435 \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043d\u0435\u0436\u0435\u043b\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0412\u043e\u0442 \u043a\u0440\u0430\u0442\u043a\u043e\u0435 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>VCB (\u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u043a\u0443\u0449\u0438\u0439 \u0447\u043e\u043f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u0449\u0435\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0435\u0434\u043a\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0438\u0441\u043a \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0448\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043d\u0435\u0437\u0430\u043f\u043d\u043e, \u0432 \u043b\u044e\u0431\u043e\u0439 \u043c\u043e\u043c\u0435\u043d\u0442<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0438 \u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u043c \u043d\u0443\u043b\u0435<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-voltage\">\u0423\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/h3>\n\n\n\n<p>\u0412\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u0442\u0435 \u043a\u0430\u043a VCB, \u0442\u0430\u043a \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u042d\u0442\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u0435\u0442 \u043a\u0430\u0442\u0443\u0448\u043a\u0443 \u0438\u043b\u0438 \u043f\u0440\u0438\u0432\u043e\u0434 \u0432\u043d\u0443\u0442\u0440\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430. \u041f\u0440\u0438 \u043f\u043e\u0434\u0430\u0447\u0435 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u2014 \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u044f \u0438\u043b\u0438 \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b.<\/p>\n\n\n\n<p>\u0414\u043b\u044f VCB \u043e\u0431\u044b\u0447\u043d\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435. \u042d\u0442\u043e \u0441\u0432\u044f\u0437\u0430\u043d\u043e \u0441 \u0442\u0435\u043c, \u0447\u0442\u043e \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0434\u043e\u043b\u0436\u0435\u043d \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0430\u0442\u044c \u0431\u043e\u043b\u0435\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u0435 \u0438 \u0442\u044f\u0436\u0435\u043b\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e. \u0412 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0447\u0430\u0441\u0442\u043e \u0432\u0441\u0442\u0440\u0435\u0447\u0430\u044e\u0442\u0441\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f 110 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, 220 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438\u043b\u0438 \u0434\u0430\u0436\u0435 \u0432\u044b\u0448\u0435.<\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u0412 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c 24 \u0412, 48 \u0412 \u0438\u043b\u0438 110 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0438\u043b\u0438 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u042d\u0442\u043e \u0443\u043f\u0440\u043e\u0449\u0430\u0435\u0442 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432 \u043f\u0430\u043d\u0435\u043b\u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0438\u0445 \u0441\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u043c\u0438 \u0440\u0435\u043b\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u043c\u0438 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u0430\u043c\u0438 (\u041f\u041b\u041a).<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u041f\u0435\u0440\u0435\u0434 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u043e\u0439 \u0432\u0441\u0435\u0433\u0434\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0439\u0442\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0434\u0438\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0438\u043b\u0438 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u0435\u0433\u043e \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u0442\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438. \u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b \u0434\u043b\u044f \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b\u0430 \u0438 \u043f\u0440\u043e\u0449\u0435 \u0432 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0438 \u0432 \u0434\u0438\u0441\u043f\u0435\u0442\u0447\u0435\u0440\u0441\u043a\u0438\u0445. \u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 VCB.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-and-endurance\">\u0417\u0430\u0449\u0438\u0442\u0430 \u0438 \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"overcurrent-protection\">\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443<\/h3>\n\n\n\n<p>\u0412\u0430\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0437\u0430\u0449\u0438\u0442\u0438\u0442\u044c \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u043e\u0442 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u041f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0434\u0438\u0442\u044c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043f\u043e\u0436\u0430\u0440. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB) \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443. \u041e\u043d \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043a\u0430\u043a \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u0442\u043e\u043a\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0442\u0430\u043a \u0438 \u043e\u043f\u0430\u0441\u043d\u044b\u0435 \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u0438\u0442\u044c\u0441\u044f VCB, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043f\u0440\u0435\u0440\u0432\u0435\u0442 \u0442\u043e\u043a, \u043a\u043e\u0433\u0434\u0430 \u043e\u043d \u0441\u0442\u0430\u043d\u0435\u0442 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0432\u044b\u0441\u043e\u043a\u0438\u043c.<\/p>\n\n\n\n<p>A <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/a> \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u043e-\u0434\u0440\u0443\u0433\u043e\u043c\u0443. \u041e\u043d \u043c\u043e\u0436\u0435\u0442 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u0442\u043e\u043a\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u043d\u043e \u0441\u0430\u043c \u043f\u043e \u0441\u0435\u0431\u0435 \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u0437\u0430\u0449\u0438\u0442\u0438\u0442\u044c \u043e\u0442 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439. \u041f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 \u0438\u043b\u0438 \u0440\u0435\u043b\u0435, \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u043b\u043d\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b.<\/p>\n\n\n\n<p>\u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 (VC)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430, \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043a\u0430\u043a \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u0447\u043d\u044b\u0435, \u0442\u0430\u043a \u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0437\u0430\u043c\u043a\u043d\u0443\u0442\u044b\u0435 \u0442\u043e\u043a\u0438.<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u0439, \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439, \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u043d\u044b\u0439 \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439, \u043d\u0435 \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f\u044b \u0437\u0430\u0449\u0438\u0442\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430, \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435, \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435, \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043e \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435\u043c \u0442\u043e\u043a\u0430 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 VCB, \u0435\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u0430 \u043f\u043e\u043b\u043d\u0430\u044f \u0437\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043e\u043a \u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043d\u043e \u0432\u0441\u0435\u0433\u0434\u0430 \u0434\u043e\u0431\u0430\u0432\u043b\u044f\u0439\u0442\u0435 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"short-circuit-capability\">\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c\u0443 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044e<\/h3>\n\n\n\n<p>\u041a\u043e\u0440\u043e\u0442\u043a\u0438\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043f\u0440\u043e\u0442\u0435\u043a\u0430\u043d\u0438\u0435 \u043e\u0433\u0440\u043e\u043c\u043d\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 \u0432 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435. \u0412\u0430\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0435 \u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c\u0441\u044f \u0441 \u0442\u0430\u043a\u0438\u043c\u0438 \u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u0441\u0438\u0442\u0443\u0430\u0446\u0438\u044f\u043c\u0438. VCB \u0441\u043e\u0437\u0434\u0430\u043d \u0438\u043c\u0435\u043d\u043d\u043e \u0434\u043b\u044f \u044d\u0442\u043e\u0439 \u0437\u0430\u0434\u0430\u0447\u0438. \u041e\u043d \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u043e\u0447\u0435\u043d\u044c \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0438 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0430\u0442\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u043f\u043e\u0441\u043b\u0435 \u044d\u0442\u043e\u0433\u043e. \u041d\u0430 VCB \u0432\u044b \u0443\u0432\u0438\u0434\u0438\u0442\u0435 \u0442\u0430\u043a\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f, \u043a\u0430\u043a Icu (\u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438) \u0438 Ics (\u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438). \u042d\u0442\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442, \u043a\u0430\u043a\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0431\u0435\u0437 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439.<\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u0438\u043c\u0435\u044e\u0442 \u0442\u0430\u043a\u0438\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a. \u041e\u043d\u0438 \u043d\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u041e\u043d\u0438 \u043c\u043e\u0433\u0443\u0442 \u0442\u043e\u043b\u044c\u043a\u043e \u043d\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u0442\u044c \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043d\u043e \u043d\u0435 \u043c\u043e\u0433\u0443\u0442 \u0435\u0433\u043e \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c. \u0414\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c VCB \u0438\u043b\u0438 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c.<\/p>\n\n\n\n<p>\u0412\u043e\u0442 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 (VCB)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b (LBS)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Icu (\u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Ics (\u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Icm (\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Icw (\u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0442\u043e\u043a)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Ipk (\u043f\u0438\u043a\u043e\u0432\u044b\u0439 \u0442\u043e\u043a, \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0439 \u0442\u043e\u043a\u043e\u043c)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0412\u0441\u0435\u0433\u0434\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 VCB \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u041e\u0434\u0438\u043d \u0442\u043e\u043b\u044c\u043a\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mechanical-endurance\">\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c<\/h3>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u043b\u043e \u0434\u043e\u043b\u0433\u043e. \u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442, \u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0440\u0430\u0437 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u043e\u043d\u043e \u0438\u0437\u043d\u043e\u0441\u0438\u0442\u0441\u044f. \u0411\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e VCB \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043b\u0430\u0441\u0441\u0430 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043e\u0442 10 000 \u0434\u043e 20 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439. \u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 VCB \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u0434\u0435\u0440\u0436\u0430\u0442\u044c 100 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0438 \u0431\u043e\u043b\u0435\u0435. \u042d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u044f\u0442\u044c VCB \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043c\u043d\u043e\u0433\u0438\u0445 \u043b\u0435\u0442, \u0435\u0441\u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 \u0435\u0433\u043e \u043f\u043e \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044e.<\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u044b\u0447\u043d\u043e \u0438\u043c\u0435\u044e\u0442 \u0435\u0449\u0435 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c. \u041e\u043d\u0438 \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u044b \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043c\u043e\u0433\u0443\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0441\u043e\u0442\u043d\u0438 \u0442\u044b\u0441\u044f\u0447 \u0438\u043b\u0438 \u0434\u0430\u0436\u0435 \u043c\u0438\u043b\u043b\u0438\u043e\u043d\u044b \u0440\u0430\u0437. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442, \u0433\u0434\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043c\u043d\u043e\u0433\u043e\u043a\u0440\u0430\u0442\u043d\u043e \u0432\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u0430\u0436\u0434\u044b\u0439 \u0434\u0435\u043d\u044c.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>VCB: \u043e\u0442 10 000 \u0434\u043e 20 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435), \u0434\u043e 100 000 (\u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0442\u0438\u043f\u044b)<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b: \u0447\u0430\u0441\u0442\u043e \u043e\u0442 \u0441\u043e\u0442\u0435\u043d \u0442\u044b\u0441\u044f\u0447 \u0434\u043e \u043c\u0438\u043b\u043b\u0438\u043e\u043d\u043e\u0432 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435, \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440. \u0414\u043b\u044f \u0440\u0435\u0434\u043a\u0438\u0445, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 VCB \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442 \u0432\u0430\u043c \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"maintenance-needs\">\u041f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438<\/h3>\n\n\n\n<p>\u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043c\u0435\u0436\u0434\u0443 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u043c (VCB) \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u041a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b. \u041a\u0430\u0436\u0434\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0438\u043c\u0435\u0435\u0442 \u0441\u0432\u043e\u0438 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0438, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0442\u0449\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0433\u0440\u0430\u0444\u0438\u043a \u0438 \u0440\u0435\u0441\u0443\u0440\u0441\u044b.<\/p>\n\n\n\n<p>VCB \u0438\u043c\u0435\u0435\u0442 \u043f\u0440\u043e\u0447\u043d\u0443\u044e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044e. \u041e\u043d \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b, \u043d\u043e \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432\u043d\u0443\u0442\u0440\u0438 VCB \u043d\u0435 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0431\u044b\u0441\u0442\u0440\u043e. \u041c\u043e\u0436\u043d\u043e \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u043d\u0430 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f\u043c\u0438, \u0438\u043d\u043e\u0433\u0434\u0430 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043b\u0435\u0442 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430\u043c\u0438. \u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0434\u0435\u0442\u0430\u043b\u0438, \u043e\u0447\u0438\u0449\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e. \u0411\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u044e\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u043f\u043e\u043b\u043d\u0443\u044e \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u043a\u0430\u0436\u0434\u044b\u0435 1\u20133 \u0433\u043e\u0434\u0430. \u0415\u0441\u043b\u0438 VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445, \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430.<\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u043e-\u0434\u0440\u0443\u0433\u043e\u043c\u0443. \u041e\u043d \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043f\u043e\u0434\u0432\u0435\u0440\u0433\u0430\u0435\u0442\u0441\u044f \u0431\u043e\u043b\u044c\u0448\u0435\u043c\u0443 \u0438\u0437\u043d\u043e\u0441\u0443. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0432\u043d\u0443\u0442\u0440\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u043c\u043e\u0433\u0443\u0442 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u0442\u044c\u0441\u044f \u0438\u043b\u0438 \u043f\u043e\u043a\u0440\u044b\u0432\u0430\u0442\u044c\u0441\u044f \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u0435\u0439 \u043f\u043e\u0441\u043b\u0435 \u043c\u043d\u043e\u0433\u043e\u043a\u0440\u0430\u0442\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0447\u0430\u0449\u0435, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438. \u041c\u043e\u0436\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u043e\u0447\u0438\u0441\u0442\u043a\u0430 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043a\u0430\u0436\u0434\u044b\u0435 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u0435\u0441\u044f\u0446\u0435\u0432. \u0422\u0430\u043a\u0436\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043a\u0430\u0442\u0443\u0448\u043a\u0443 \u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u043f\u0440\u0438\u0437\u043d\u0430\u043a\u043e\u0432 \u0438\u0437\u043d\u043e\u0441\u0430.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0421\u043e\u0441\u0442\u0430\u0432\u044c\u0442\u0435 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u043f\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e \u0434\u043b\u044f \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430. \u0420\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u044b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u0441\u0432\u043e\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0442\u044c \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0438 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0438\u0445 \u043f\u0440\u043e\u0441\u0442\u043e\u0435\u0432.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0412\u043e\u0442 \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0441\u0440\u0430\u0432\u043d\u0438\u0442\u044c \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u0449\u0438\u0435 \u0437\u0430\u0434\u0430\u0447\u0438<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0436\u0438\u0434\u0430\u0435\u043c\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439 (1\u20133 \u0433\u043e\u0434\u0430)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c, \u0447\u0438\u0441\u0442\u0438\u0442\u044c, \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c, \u0441\u043c\u0430\u0437\u044b\u0432\u0430\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10\u201320 \u043b\u0435\u0442 \u0438 \u0431\u043e\u043b\u0435\u0435<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439 (3\u201312 \u043c\u0435\u0441\u044f\u0446\u0435\u0432)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435, \u043e\u0447\u0438\u0441\u0442\u0438\u0442\u0435, \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>5\u201310 \u043b\u0435\u0442<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0438\u043c\u0435\u0442\u044c \u043f\u043e\u0434 \u0440\u0443\u043a\u043e\u0439 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u0447\u0430\u0441\u0442\u0438 \u0434\u043b\u044f \u043e\u0431\u043e\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432. \u0414\u043b\u044f VCB \u0432\u0430\u043c \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043d\u0430\u0434\u043e\u0431\u0438\u0442\u044c\u0441\u044f \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438\u043b\u0438 \u0441\u043c\u0430\u0437\u043e\u0447\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b. \u0414\u043b\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0438\u043c\u0435\u0442\u044c \u0432 \u0437\u0430\u043f\u0430\u0441\u0435 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0438. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u044f, \u0435\u0441\u043b\u0438 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043f\u043e\u0434\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u0441\u044c.<\/p>\n\n\n\n<p>\u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u044c \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u043f\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e. \u041a\u0430\u0436\u0434\u0430\u044f \u043c\u043e\u0434\u0435\u043b\u044c \u0438\u043c\u0435\u0435\u0442 \u043e\u0441\u043e\u0431\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f. \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u0442\u044c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u0438 \u043e\u0431\u0443\u0447\u0438\u0442\u044c \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b. \u0425\u043e\u0440\u043e\u0448\u0430\u044f \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u043e\u0442\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0442\u044c \u0434\u0430\u0442\u044b \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u0432\u044b\u044f\u0432\u043b\u044f\u0442\u044c \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0438.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0441\u043b\u0435\u0434\u043e\u0432 \u0433\u043e\u0440\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u0438.<\/p><\/li>\n\n\n\n<li><p>\u041e\u0447\u0438\u0441\u0442\u0438\u0442\u0435 \u043a\u043e\u0440\u043f\u0443\u0441 \u043e\u0442 \u043f\u044b\u043b\u0438 \u0438 \u043c\u0443\u0441\u043e\u0440\u0430.<\/p><\/li>\n\n\n\n<li><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0440\u0430\u0431\u043e\u0442\u0443 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0438 \u043f\u0440\u0443\u0436\u0438\u043d.<\/p><\/li>\n\n\n\n<li><p>\u0421\u043c\u0430\u0437\u044b\u0432\u0430\u0439\u0442\u0435 \u0434\u0432\u0438\u0436\u0443\u0449\u0438\u0435\u0441\u044f \u0447\u0430\u0441\u0442\u0438 \u043f\u043e \u043c\u0435\u0440\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0415\u0441\u043b\u0438 \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435, \u0432\u044b \u0440\u0438\u0441\u043a\u0443\u0435\u0442\u0435 \u0441\u0442\u043e\u043b\u043a\u043d\u0443\u0442\u044c\u0441\u044f \u0441 \u043f\u043e\u043b\u043e\u043c\u043a\u043e\u0439 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0443\u0433\u0440\u043e\u0437\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438. \u0420\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u044b\u0439 \u0443\u0445\u043e\u0434 \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043f\u0440\u043e\u0431\u043b\u0435\u043c. \u0412\u044b \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u0435 \u0434\u0435\u043d\u044c\u0433\u0438 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u0435 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043d\u0430 \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a. \u042d\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u043e\u0432 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0412\u044b \u0434\u0435\u043b\u0430\u0435\u0442\u0435 \u0441\u0432\u043e\u044e \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439, \u0443\u0434\u0435\u043b\u044f\u044f \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u0412\u044b \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442\u0435 \u0441\u0432\u043e\u0438 \u0438\u043d\u0432\u0435\u0441\u0442\u0438\u0446\u0438\u0438 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442\u0435 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"applications-and-use-cases\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0438 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57.webp\" alt=\"\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0438 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f\" class=\"wp-image-1536\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/ff4ec2c775fa4995964e90a256229f57-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0418\u0441\u0442\u043e\u0447\u043d\u0438\u043a \u0438\u0437\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/unsplash.com\">unsplash<\/a><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-applications\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f VCB<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"power-distribution\">\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0447\u0430\u0441\u0442\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432 \u0441\u0435\u0442\u044f\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u041e\u043d\u0438 \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u0444\u0438\u0434\u0435\u0440\u044b, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u043a\u0430\u043a \u0432 \u0433\u043e\u0440\u043e\u0434\u0441\u043a\u0438\u0445, \u0442\u0430\u043a \u0438 \u0432 \u0441\u0435\u043b\u044c\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u043f\u043e\u0434\u0430\u0447\u0443 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0441\u0431\u043e\u044f\u0445. \u041d\u0430 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f\u0445 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439, \u043f\u0435\u0447\u0435\u0439 \u0438 \u0434\u0440\u0443\u0433\u043e\u0433\u043e \u0442\u044f\u0436\u0435\u043b\u043e\u0433\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u042d\u0442\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0442\u0430\u043a\u0436\u0435 \u0438\u0433\u0440\u0430\u044e\u0442 \u043a\u043b\u044e\u0447\u0435\u0432\u0443\u044e \u0440\u043e\u043b\u044c \u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0436\u0435\u043b\u0435\u0437\u043d\u044b\u0445 \u0434\u043e\u0440\u043e\u0433, \u0433\u0434\u0435 \u043e\u043d\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0442\u044f\u0433\u043e\u0432\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n\n\n\n<p>\u041d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u0430 \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u0432 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u043f\u043e\u043a\u0430\u0437\u0430\u043d\u044b \u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u0441\u0446\u0435\u043d\u0430\u0440\u0438\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f VCB:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u0446\u0435\u043d\u0430\u0440\u0438\u0439 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0435\u0442\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0444\u0438\u0434\u0435\u0440\u044b, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438, \u043f\u0435\u0447\u0438 \u0438 \u0442\u044f\u0436\u0435\u043b\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 \u0437\u0430\u0432\u043e\u0434\u0430\u0445<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0436\u0435\u043b\u0435\u0437\u043d\u044b\u0445 \u0434\u043e\u0440\u043e\u0433<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0442\u044f\u0433\u043e\u0432\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0432\u0435\u0442\u0440\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0437\u0430\u0449\u0438\u0442\u0443 \u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0432\u0435\u0442\u0440\u043e\u0432\u044b\u0445 \u0442\u0443\u0440\u0431\u0438\u043d<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0413\u043e\u0440\u043d\u044b\u0435 \u0440\u0430\u0431\u043e\u0442\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0432 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0441\u0442\u0435\u043f\u0435\u043d\u044c\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043b\u0438\u043d\u0438\u0439, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0438 \u0448\u0438\u043d \u0432 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>VCB \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0438 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"high-voltage-systems\">\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/h4>\n\n\n\n<p>\u0412\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 VCB \u0432 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445, \u043f\u043e\u0442\u043e\u043c\u0443 \u0447\u0442\u043e \u043e\u043d\u0438 \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0441\u0442\u0440\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0438\u0435 \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u041a \u0442\u0430\u043a\u0438\u043c \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c \u043e\u0442\u043d\u043e\u0441\u044f\u0442\u0441\u044f \u0432\u0435\u0442\u0440\u043e\u0432\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u0438, \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0438\u0435 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f \u0438 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438. \u041d\u0430 \u0432\u0435\u0442\u0440\u043e\u0432\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 VCB \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u0442\u0443\u0440\u0431\u0438\u043d\u044b \u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0446\u0435\u043f\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u0412 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 VCB \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0432 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445. \u041f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 VCB \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043b\u0438\u043d\u0438\u0439, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0438 \u0448\u0438\u043d.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"contactor-applications\">\u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"motor-control\">\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u043c<\/h4>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0447\u0430\u0449\u0435 \u0432\u0441\u0435\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438. \u041e\u043d\u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0437\u0430\u043f\u0443\u0441\u043a\u0430\u0442\u044c \u0438 \u043e\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438 \u0432 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430\u0445. \u0412 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u043e\u0442\u043e\u043f\u043b\u0435\u043d\u0438\u044f, \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u0438 \u0438 \u043a\u043e\u043d\u0434\u0438\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442 \u043a\u043e\u043c\u043f\u0440\u0435\u0441\u0441\u043e\u0440\u0430\u043c\u0438, \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0442\u043e\u0440\u043e\u0432 \u0438 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0442\u043e\u0440\u0430\u043c\u0438. \u041e\u043d\u0438 \u0442\u0430\u043a\u0436\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0434\u043b\u044f \u043d\u0430\u0441\u043e\u0441\u043e\u0432, \u043a\u043e\u043d\u0432\u0435\u0439\u0435\u0440\u043d\u044b\u0445 \u043b\u0435\u043d\u0442 \u0438 \u0441\u043c\u0435\u0441\u0438\u0442\u0435\u043b\u0435\u0439. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435\u0437\u0430\u043c\u0435\u043d\u0438\u043c\u044b\u043c\u0438 \u0434\u043b\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u041d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u0430 \u0442\u0430\u0431\u043b\u0438\u0446\u0430 \u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0445 \u0441\u043b\u0443\u0447\u0430\u0435\u0432 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f \u0437\u0430\u044f\u0432\u043a\u0438<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0435 \u0441\u043b\u0443\u0447\u0430\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u043c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0437\u0430\u043f\u0443\u0441\u043a\/\u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u0432 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u043e\u0442\u043e\u043f\u043b\u0435\u043d\u0438\u044f, \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u0438 \u0438 \u043a\u043e\u043d\u0434\u0438\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u043e\u0437\u0434\u0443\u0445\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043c\u043f\u0440\u0435\u0441\u0441\u043e\u0440\u0430\u043c\u0438, \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0442\u043e\u0440\u043e\u0432 \u0438 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0442\u043e\u0440\u0430\u043c\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0442\u043e\u043f\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043d\u0435\u0440\u0433\u0438\u044f \u0434\u043b\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0435\u0447\u0435\u0439 \u0438 \u043a\u043e\u0442\u043b\u043e\u0432<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0446\u0435\u043f\u044f\u043c\u0438 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0430\u0441\u043e\u0441\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0426\u0438\u0440\u043a\u0443\u043b\u044f\u0446\u0438\u044f \u0432\u043e\u0434\u044b \u0438 \u0434\u043e\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043c\u043f\u0440\u0435\u0441\u0441\u043e\u0440\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0425\u043e\u043b\u043e\u0434\u0438\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u043a\u043e\u043c\u043f\u0440\u0435\u0441\u0441\u043e\u0440\u044b \u0432\u043e\u0437\u0434\u0443\u0445\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0432\u0435\u0439\u0435\u0440\u043d\u044b\u0435 \u043b\u0435\u043d\u0442\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0432\u0438\u0436\u0435\u043d\u0438\u0435 \u043d\u0430 \u0443\u043f\u0430\u043a\u043e\u0432\u043e\u0447\u043d\u044b\u0445 \u0438 \u0441\u0431\u043e\u0440\u043e\u0447\u043d\u044b\u0445 \u043b\u0438\u043d\u0438\u044f\u0445<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043c\u0435\u0441\u0438\u0442\u0435\u043b\u0438 \u0438 \u043c\u0435\u0448\u0430\u043b\u043a\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0438\u0449\u0435\u0432\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u0441\u043c\u0435\u0448\u0438\u0432\u0430\u043d\u0438\u0435<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0440\u0430\u0437\u0434\u0435\u043b\u0438\u0442\u044c \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435 \u0446\u0435\u043f\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"frequent-switching\">\u0427\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h4>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u044e\u0442, \u043a\u043e\u0433\u0434\u0430 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435. \u041e\u043d\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u044e\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435, \u043f\u043e\u0432\u0442\u043e\u0440\u044f\u044e\u0449\u0438\u0435\u0441\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435\u043c \u043f\u043e \u0440\u0430\u0441\u043f\u0438\u0441\u0430\u043d\u0438\u044e \u0438\u043b\u0438 \u0440\u0430\u0431\u043e\u0442\u0430 \u043a\u043e\u043d\u0432\u0435\u0439\u0435\u0440\u043d\u044b\u0445 \u043b\u0435\u043d\u0442. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043b\u0435\u0433\u043a\u043e \u0440\u0430\u0441\u0448\u0438\u0440\u0438\u0442\u044c \u0441\u0432\u043e\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443, \u0434\u043e\u0431\u0430\u0432\u0438\u0432 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b. \u0422\u0430\u043a\u0430\u044f \u0433\u0438\u0431\u043a\u043e\u0441\u0442\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u043c\u0430\u0441\u0448\u0442\u0430\u0431\u0438\u0440\u0443\u0435\u043c\u0443\u044e \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0443\u044e \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044e.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0443\u0441\u043a\u0430 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u043f\u0443\u0441\u043a\u0430 \u0438 \u0440\u0430\u0431\u043e\u0442\u044b.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b HVAC \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043e\u0439, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u044f \u043a\u043e\u043c\u043f\u0440\u0435\u0441\u0441\u043e\u0440\u044b \u0438 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0442\u043e\u0440\u044b.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u043e\u0441\u0443\u0449\u0435\u0441\u0442\u0432\u043b\u044f\u0442\u044c \u043f\u043b\u0430\u043d\u043e\u0432\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c\u0438 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"selection-criteria\">\u041a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043e\u0442\u0431\u043e\u0440\u0430<\/h3>\n\n\n\n<p>\u041f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0447\u0435\u0441\u0442\u044c \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b. \u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0438 \u0437\u0430\u0449\u0438\u0449\u0430\u0442\u044c \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0432\u0430\u043c \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0432\u044b\u0431\u0440\u0430\u0442\u044c VCB. \u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f, \u043b\u0443\u0447\u0448\u0438\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0431\u0443\u0434\u0435\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440. \u0423\u0447\u0442\u0438\u0442\u0435 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0447\u0430\u0441\u0442\u043e\u0442\u0443 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0437\u0430\u0449\u0438\u0442\u0435. \u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u043e\u0439, \u043a\u043e\u0433\u0434\u0430 \u0432\u044b \u043f\u043e\u0434\u0431\u0438\u0440\u0430\u0435\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0433\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u043f\u0435\u0440\u0435\u0434 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435\u043c \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0432\u0441\u0435\u0433\u0434\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0439\u0442\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435, \u0442\u043e\u043a \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044e \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"technical-comparison-table\">\u0422\u0430\u0431\u043b\u0438\u0446\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vcb-vs-contactor-summary\">VCB \u043f\u0440\u043e\u0442\u0438\u0432 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430: \u043a\u0440\u0430\u0442\u043a\u043e\u0435 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435<\/h3>\n\n\n\n<p>\u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043c\u0435\u0436\u0434\u0443 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u043c (VCB) \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0441\u0442\u0438 \u0447\u0435\u0442\u043a\u043e\u0435 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435. \u0412 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u043d\u043e\u0439 \u043d\u0438\u0436\u0435 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u044b \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u0430\u0436\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043e\u0431\u043e\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432. \u042d\u0442\u043e \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u043f\u043e\u043d\u044f\u0442\u044c, \u043a\u0430\u043a \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043a\u0430\u0436\u0434\u043e\u0435 \u0438\u0437 \u043d\u0438\u0445 \u0438 \u0447\u0435\u0433\u043e \u043c\u043e\u0436\u043d\u043e \u043e\u0436\u0438\u0434\u0430\u0442\u044c \u043e\u0442 \u0438\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u044f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0446\u0435\u043f\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0427\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f (\u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0431\u043e\u043b\u044c\u0448\u0438\u0435 \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439 (\u043d\u0435 \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u043e\u0439<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438, \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u044c\u0448\u0435 \u0438\u0441\u043a\u0440\u0435\u043d\u0438\u044f, \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0422\u0435\u043a\u0443\u0449\u0438\u0439 \u0447\u043e\u043f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u044b\u0447\u043d\u043e \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0437\u044b\u0432\u0430\u0442\u044c \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0435\u0434\u043a\u0438\u0439, \u043d\u0438\u0437\u043a\u0438\u0439 \u0440\u0438\u0441\u043a \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c, \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u0433\u0430\u0448\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0431\u043e\u043b\u0435\u0435 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u043e\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0440\u0435\u0434\u043d\u0435\u0435 \u0434\u043e \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e (\u043e\u0442 1 \u043a\u0412 \u0434\u043e 38 \u043a\u0412)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439 \u0434\u043e \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e (\u0442\u0438\u043f\u0438\u0447\u043d\u043e \u0434\u043e 1,1 \u043a\u0412)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439 (\u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f (\u0442\u044b\u0441\u044f\u0447\u0438 \u0446\u0438\u043a\u043b\u043e\u0432 \u0432 \u0447\u0430\u0441)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0440\u0430\u0431\u043e\u0442\u044b<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u043d\u044c\u0448\u0430\u044f \u0441\u0438\u043b\u0430, \u043f\u0440\u043e\u0441\u0442\u043e\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u044f\u044e\u0449\u0430\u044f \u043a\u0430\u0442\u0443\u0448\u043a\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430, \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u0442, \u0442\u0440\u0435\u0431\u0443\u044e\u0442\u0441\u044f \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c\u0443 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430, \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u0442, \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u0442\u044c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 000\u2013100 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100 000\u20131 000 000+ \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u041f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0435, \u0434\u043b\u0438\u043d\u043d\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0427\u0430\u0441\u0442\u044b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043d\u0430 \u0432\u044b\u0441\u043e\u043a\u043e\u043c \u0443\u0440\u043e\u0432\u043d\u0435<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0443<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439, \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442 \u043c\u0435\u0441\u0442\u043e \u043d\u0430 \u043f\u0430\u043d\u0435\u043b\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u044c\u0448\u0430\u044f \u043f\u043b\u043e\u0449\u0430\u0434\u044c<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044e<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439, \u0434\u0443\u0433\u043e\u0432\u044b\u0435 \u0436\u0435\u043b\u043e\u0431\u0430 \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0442\u0441\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0436\u043d\u044f\u044f \u0447\u0430\u0441\u0442\u044c, \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043e\u0447\u0438\u0441\u0442\u043a\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0423\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0448\u0435 (110 \u0412\u2013220 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e\/\u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0436\u043d\u0438\u0439 (24 \u0412\u2013110 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e\/\u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438, \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f, \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u044d\u0442\u0443 \u0442\u0430\u0431\u043b\u0438\u0446\u0443, \u0447\u0442\u043e\u0431\u044b \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0435 \u0432\u0430\u0448\u0438\u043c \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044f\u043c. \u041f\u0435\u0440\u0435\u0434 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435\u043c \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u043e\u0431\u0440\u0430\u0442\u0438\u0442\u0435 \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438, \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"bullet-point-highlights\">\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043c\u043e\u043c\u0435\u043d\u0442\u044b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 VCB, \u043a\u043e\u0433\u0434\u0430 \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u0437\u0430\u0449\u0438\u0442\u0438\u0442\u044c \u0441\u0432\u043e\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0438 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u0442\u043e\u043a\u043e\u0432.<\/p><\/li>\n\n\n\n<li><p>\u0412\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u0443\u0434\u043e\u0431\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u0438\u043b\u0438 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435\u043c.<\/p><\/li>\n\n\n\n<li><p>VCB \u0431\u044b\u0441\u0442\u0440\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0442 \u0434\u0443\u0433\u0438 \u0438 \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043e\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043c\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u043e\u0432 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f-\u0432\u044b\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043d\u043e \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0431\u043e\u043b\u044c\u0448\u0435\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u0443\u0433\u0438.<\/p><\/li>\n\n\n\n<li><p>VCB \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u0437\u044b\u0432\u0430\u0442\u044c \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0442\u043e\u043a\u0430, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0440\u0438\u0441\u043a\u0430 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0435\u0434\u043a\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0442 \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432 \u043f\u0430\u043d\u0435\u043b\u044f\u0445 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438.<\/p><\/li>\n\n\n\n<li><p>VCB \u044d\u043a\u043e\u043d\u043e\u043c\u044f\u0442 \u043c\u0435\u0441\u0442\u043e \u0438 \u043b\u0443\u0447\u0448\u0435 \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u0441\u0442\u043e\u044f\u0442 \u043f\u044b\u043b\u0438 \u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f\u043c, \u0447\u0435\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b.<\/p><\/li>\n\n\n\n<li><p>\u0415\u0441\u043b\u0438 \u0432\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0434\u043e\u0431\u0430\u0432\u0438\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0437\u0430\u0449\u0438\u0442\u044b.<\/p><\/li>\n\n\n\n<li><p>VCB \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u043e\u043b\u044c\u0448\u0435 \u0438 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u043d\u043e \u0438\u0445 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0442\u043e\u043b\u044c\u043a\u043e \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u043b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0441 \u0447\u0430\u0441\u0442\u044b\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u0430 \u043d\u0430\u0434\u0435\u0436\u043d\u0430\u044f \u0437\u0430\u0449\u0438\u0442\u0430 \u0438 \u043d\u0438\u0437\u043a\u0438\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435, \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 VCB. \u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u0438 \u043f\u043e\u0432\u0442\u043e\u0440\u044f\u044e\u0449\u0435\u0435\u0441\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435, \u043b\u0443\u0447\u0448\u0438\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0431\u0443\u0434\u0435\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"choosing-the-right-device\">\u0412\u044b\u0431\u043e\u0440 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"decision-factors\">\u0424\u0430\u043a\u0442\u043e\u0440\u044b, \u0432\u043b\u0438\u044f\u044e\u0449\u0438\u0435 \u043d\u0430 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/h3>\n\n\n\n<p>\u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043c\u0435\u0436\u0434\u0443 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u043c (VCB) \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0432\u0430\u0436\u043d\u044b\u0445 \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432. \u041a\u0430\u0436\u0434\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0438\u043c\u0435\u0435\u0442 \u0441\u0432\u043e\u0438 \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u0432\u0430\u0448\u0435\u043c\u0443 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044e. \u041d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u0430\u0436\u043d\u044b\u0435 \u043c\u043e\u043c\u0435\u043d\u0442\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>\u041d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c<\/strong>: \u0412\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0431\u0443\u0434\u0435\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0432\u0441\u0435\u0433\u0434\u0430. VCB \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0438 \u043d\u0438\u0437\u043a\u0438\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u043a \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e. \u042d\u0442\u043e \u043e\u0447\u0435\u043d\u044c \u0432\u0430\u0436\u043d\u043e \u0432 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445, \u0433\u0434\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u0435 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b.<\/p><\/li>\n\n\n\n<li><p><strong>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u044c<\/strong>: VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u0430\u043a\u0443\u0443\u043c \u0432\u043c\u0435\u0441\u0442\u043e \u0433\u0430\u0437\u043e\u0432 \u0438\u043b\u0438 \u043c\u0430\u0441\u0435\u043b. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u043b\u0443\u0447\u0448\u0438\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c, \u0435\u0441\u043b\u0438 \u0432\u044b \u0437\u0430\u0431\u043e\u0442\u0438\u0442\u0435\u0441\u044c \u043e\u0431 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435. \u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u043f\u0430\u0440\u043d\u0438\u043a\u043e\u0432\u044b\u0445 \u0433\u0430\u0437\u043e\u0432.<\/p><\/li>\n\n\n\n<li><p><strong>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438<\/strong>: VCB \u043b\u0443\u0447\u0448\u0435 \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u043c\u0438 \u0434\u0443\u0433\u0430\u043c\u0438, \u0447\u0435\u043c \u043c\u043d\u043e\u0433\u0438\u0435 \u0434\u0440\u0443\u0433\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438. \u041e\u043d\u0438 \u0431\u044b\u0441\u0442\u0440\u043e \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0433\u0430\u0441\u044f\u0442 \u0434\u0443\u0433\u0438, \u0447\u0442\u043e \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0432\u0430\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435.<\/p><\/li>\n\n\n\n<li><p><strong>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/strong>: \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435. \u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u0438 \u0443\u0440\u043e\u0432\u043d\u044e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p><\/li>\n\n\n\n<li><p><strong>\u0420\u0430\u0437\u0440\u0443\u0448\u0430\u044e\u0449\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430<\/strong>: \u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u043c\u043e\u0436\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0441\u0430\u043c\u044b\u0439 \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u0441 \u043a\u043e\u0442\u043e\u0440\u044b\u043c \u043c\u043e\u0436\u0435\u0442 \u0441\u0442\u043e\u043b\u043a\u043d\u0443\u0442\u044c\u0441\u044f \u0432\u0430\u0448\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u0430.<\/p><\/li>\n\n\n\n<li><p><strong>\u0414\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f<\/strong>: \u0412\u044b\u0431\u0438\u0440\u0430\u0439\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0442 \u0434\u043e\u043b\u0433\u043e \u0438 \u0431\u0443\u0434\u0435\u0442 \u043f\u0440\u043e\u0441\u0442\u044b\u043c \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438. \u042d\u0442\u043e \u0441\u043d\u0438\u0437\u0438\u0442 \u0432\u0430\u0448\u0438 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u044f.<\/p><\/li>\n\n\n\n<li><p><strong>\u0418\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438<\/strong>: \u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u0442\u044c\u0441\u044f \u043a \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0438\u043b\u0438 IoT. \u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0443\u0436\u0435\u043d \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u0438\u043b\u0438 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433, \u043e\u0431\u0440\u0430\u0442\u0438\u0442\u0435 \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u0430 \u044d\u0442\u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u0438.<\/p><\/li>\n\n\n\n<li><p><strong>\u0421\u0440\u0435\u0434\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438<\/strong>: \u041f\u043e\u0434\u0443\u043c\u0430\u0439\u0442\u0435, \u0433\u0434\u0435 \u0432\u044b \u0431\u0443\u0434\u0435\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e. \u041f\u044b\u043b\u044c, \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0432\u043b\u0438\u044f\u0442\u044c \u043d\u0430 \u0432\u0430\u0448 \u0432\u044b\u0431\u043e\u0440.<\/p><\/li>\n\n\n\n<li><p><strong>\u0420\u0435\u043f\u0443\u0442\u0430\u0446\u0438\u044f \u0431\u0440\u0435\u043d\u0434\u0430<\/strong>: \u041d\u0430\u0434\u0435\u0436\u043d\u044b\u0435 \u0431\u0440\u0435\u043d\u0434\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a Siemens, Eaton, Schneider Electric \u0438 Weisho Electric, \u0447\u0430\u0441\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043b\u0443\u0447\u0448\u0443\u044e \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0443 \u0438 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u041f\u0435\u0440\u0435\u0434 \u0442\u0435\u043c \u043a\u0430\u043a \u0441\u0434\u0435\u043b\u0430\u0442\u044c \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440, \u0432\u0441\u0435\u0433\u0434\u0430 \u043e\u0446\u0435\u043d\u0438\u0432\u0430\u0439\u0442\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443. \u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u043d\u043d\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"practical-recommendations\">\u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438<\/h3>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0432\u043e\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0441\u043e\u0432\u0435\u0442\u0430\u043c\u0438 \u044d\u043a\u0441\u043f\u0435\u0440\u0442\u043e\u0432, \u0447\u0442\u043e\u0431\u044b \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043b\u0443\u0447\u0448\u0435\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0433\u043e \u0437\u0434\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u0430. \u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u043d\u043e, \u043a\u0430\u043a\u043e\u0439 \u0442\u0438\u043f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0430\u044f \u0441\u0440\u0435\u0434\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041b\u0443\u0447\u0448\u0438\u0439 \u0442\u0438\u043f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0438\u0447\u0438\u043d\u0430 \u0432\u044b\u0431\u043e\u0440\u0430<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u044b\u043b\u044c\u043d\u044b\u0439\/\u0413\u0440\u044f\u0437\u043d\u044b\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u043f\u0430\u0434\u0430\u043d\u0438\u0435 \u043f\u044b\u043b\u0438 \u0438 \u0447\u0430\u0441\u0442\u0438\u0446<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043b\u0430\u0436\u043d\u0430\u044f\/\u043a\u043e\u0440\u0440\u043e\u0437\u0438\u043e\u043d\u043d\u0430\u044f \u0441\u0440\u0435\u0434\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u0435\u0437 \u043c\u0430\u0441\u043b\u0430 \u0438 \u0433\u0430\u0437\u0430, \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u043e\u043d\u043d\u0430\u044f \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0435 \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SF6 \u0438\u043b\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440, \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044c \u0432 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u0432\u0437\u0440\u044b\u0432\u0430<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u0442\u0430\u043a\u0436\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u0435 \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p><\/li>\n\n\n\n<li><p>\u041f\u043e\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u043d\u0430 \u0440\u0430\u0437\u0440\u044b\u0432\u043d\u0443\u044e \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c, \u0447\u0442\u043e\u0431\u044b \u0443\u0431\u0435\u0434\u0438\u0442\u044c\u0441\u044f, \u0447\u0442\u043e \u043e\u043d\u0430 \u043c\u043e\u0436\u0435\u0442 \u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c\u0441\u044f \u0441 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u043c\u0438.<\/p><\/li>\n\n\n\n<li><p>\u041f\u043e\u0434\u0443\u043c\u0430\u0439\u0442\u0435, \u043a\u0430\u043a \u0447\u0430\u0441\u0442\u043e \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0446\u0435\u043f\u044c. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u0430 VCB \u2014 \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0438 \u0440\u0435\u0434\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/p><\/li>\n\n\n\n<li><p>\u0423\u0447\u0438\u0442\u044b\u0432\u0430\u0439\u0442\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 VCB \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0438\u043b\u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u043d\u044b\u0445 \u043c\u0435\u0441\u0442\u0430\u0445.<\/p><\/li>\n\n\n\n<li><p>\u0412\u044b\u0431\u0438\u0440\u0430\u0439\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0441 \u0445\u043e\u0440\u043e\u0448\u0435\u0439 \u0440\u0435\u043f\u0443\u0442\u0430\u0446\u0438\u0435\u0439 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u043e\u0439.<\/p><\/li>\n\n\n\n<li><p>\u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u044b \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438, \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043c\u043e\u0434\u0435\u043b\u044c, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0441 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u043e\u0439 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\ud83d\udee0\ufe0f <strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0435\u0439 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u0446\u0435\u043b\u0435\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b. \u041d\u0435 \u0442\u043e\u0440\u043e\u043f\u0438\u0442\u0435\u0441\u044c, \u0441\u0440\u0430\u0432\u043d\u0438\u0442\u0435 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0438 \u043e\u0431\u0440\u0430\u0442\u0438\u0442\u0435\u0441\u044c \u043a \u044d\u043a\u0441\u043f\u0435\u0440\u0442\u0430\u043c, \u0435\u0441\u043b\u0438 \u0443 \u0432\u0430\u0441 \u0435\u0441\u0442\u044c \u0432\u043e\u043f\u0440\u043e\u0441\u044b.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0412\u044b \u0443\u0437\u043d\u0430\u043b\u0438, \u0447\u0442\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 (VCB) \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u0432\u0430\u0448\u0443 \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u043f\u0440\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u0445, \u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435. VCB \u043e\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u044e\u0442 \u043e\u043f\u0430\u0441\u043d\u044b\u0435 \u0442\u043e\u043a\u0438 \u0438 \u0441\u043d\u0438\u0436\u0430\u044e\u0442 \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0438 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b. \u0412\u044b\u0431\u043e\u0440 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>VCB \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0442 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044e.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0414\u043b\u044f \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u043d\u0430\u0438\u043b\u0443\u0447\u0448\u0438\u0445 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u043e\u0432 \u043f\u0440\u043e\u0430\u043d\u0430\u043b\u0438\u0437\u0438\u0440\u0443\u0439\u0442\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438\u043b\u0438 \u043f\u0440\u043e\u043a\u043e\u043d\u0441\u0443\u043b\u044c\u0442\u0438\u0440\u0443\u0439\u0442\u0435\u0441\u044c \u0441\u043e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u043e\u043c, \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u0441\u0434\u0435\u043b\u0430\u0442\u044c \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-main-difference-between-a-vcb-and-a-contactor\">\u0412 \u0447\u0435\u043c \u0437\u0430\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c?<\/h3>\n\n\n\n<p>\u0412\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 VCB \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u0412\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a. VCB \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-use-a-contactor-instead-of-a-vcb\">\u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0432\u043c\u0435\u0441\u0442\u043e VCB?<\/h3>\n\n\n\n<p>\u041d\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0432\u043c\u0435\u0441\u0442\u043e VCB. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u0422\u043e\u043b\u044c\u043a\u043e VCB \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u043f\u0440\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\u0445 \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430\u0445.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"where-do-you-install-vcbs-and-contactors\">\u0413\u0434\u0435 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u044e\u0442\u0441\u044f VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b?<\/h3>\n\n\n\n<p>\u0412\u044b \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442\u0435 VCB \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u044f\u0445, \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u043c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0438. \u0412\u044b \u0440\u0430\u0437\u043c\u0435\u0449\u0430\u0435\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432 \u0446\u0435\u043d\u0442\u0440\u0430\u0445 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u043f\u0430\u043d\u0435\u043b\u044f\u0445 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u0446\u0435\u043f\u044f\u0445 \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-often-do-you-need-to-maintain-a-vcb-or-contactor\">\u041a\u0430\u043a \u0447\u0430\u0441\u0442\u043e \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435?<a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\"> VCB<\/a> \u0438\u043b\u0438 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/\" data-type=\"page\" data-id=\"1186\">\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/a>?<\/h3>\n\n\n\n<p>\u0412\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0435\u0442\u0435 VCB \u043a\u0430\u0436\u0434\u044b\u0435 1\u20133 \u0433\u043e\u0434\u0430. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0435\u0442\u0435 \u0447\u0430\u0449\u0435, \u043e\u0431\u044b\u0447\u043d\u043e \u043a\u0430\u0436\u0434\u044b\u0435 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u0435\u0441\u044f\u0446\u0435\u0432. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u0447\u0430\u0449\u0435.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"do-vcbs-and-contactors-cause-voltage-spikes\">\u0412\u044b\u0437\u044b\u0432\u0430\u044e\u0442 \u043b\u0438 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f?<\/h3>\n\n\n\n<p>VCB \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u0437\u044b\u0432\u0430\u0442\u044c \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0442\u043e\u043a\u0430. \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0441\u0432\u043e\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0440\u0438\u0441\u043a\u0430 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0435\u0434\u043a\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0442 \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"which-device-lasts-longer-a-vcb-or-a-contactor\">\u041a\u0430\u043a\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0441\u043b\u0443\u0436\u0438\u0442 \u0434\u043e\u043b\u044c\u0448\u0435: VCB \u0438\u043b\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440?<\/h3>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u043e\u043b\u044c\u0448\u0435 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f. VCB \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u043e\u043b\u044c\u0448\u0435 \u043f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u0434\u043b\u044f \u0440\u0435\u0434\u043a\u0438\u0445, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439. \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u0442\u044c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044f\u043c\u0438 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-control-both-devices-remotely\">\u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c \u043e\u0431\u043e\u0438\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e?<\/h3>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c \u043a\u0430\u043a VCB, \u0442\u0430\u043a \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438. \u0414\u043b\u044f \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u0440\u0435\u043b\u0435 \u0438\u043b\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u0412\u0441\u0435\u0433\u0434\u0430 \u0441\u043b\u0435\u0434\u0443\u0439\u0442\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u043f\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435 \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u0437\u0430\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u0432 \u0437\u0430\u0449\u0438\u0442\u0435 \u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438: VCB \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438, \u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/p>","protected":false},"author":3,"featured_media":1535,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-1537","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=1537"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1537\/revisions"}],"predecessor-version":[{"id":3526,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1537\/revisions\/3526"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/1535"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=1537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=1537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=1537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}