{"id":1549,"date":"2025-11-29T17:33:54","date_gmt":"2025-11-29T17:33:54","guid":{"rendered":"https:\/\/xbrele.com\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/"},"modified":"2026-04-07T15:15:29","modified_gmt":"2026-04-07T15:15:29","slug":"advantages-of-vacuum-contactor-reliable-safe-efficient-choice","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/","title":{"rendered":"\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430, \u043d\u0430 \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u0443\u0436\u0435 \u0441\u0435\u0439\u0447\u0430\u0441"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/6974c66882a84f82a55f088cc0947681.jpg\" alt=\"\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430, \u043d\u0430 \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u0443\u0436\u0435 \u0441\u0435\u0439\u0447\u0430\u0441\" class=\"wp-image-1547\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/6974c66882a84f82a55f088cc0947681.jpg 1408w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/6974c66882a84f82a55f088cc0947681-300x164.jpg 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/6974c66882a84f82a55f088cc0947681-1024x559.jpg 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/6974c66882a84f82a55f088cc0947681-768x419.jpg 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/6974c66882a84f82a55f088cc0947681-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435 \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0435, \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0435 \u0438 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0432\u0430\u0448\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c. \u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0442\u0430\u043c, \u0433\u0434\u0435 \u044d\u0442\u043e \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u0430\u0436\u043d\u043e. \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u0438\u043b\u0438 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0439 \u0432\u0430\u043a\u0443\u0443\u043c \u0434\u043b\u044f \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044c \u0432 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u0438 \u043f\u043e\u0432\u044b\u0448\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0438\u043c \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u0445.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u041a\u043b\u044e\u0447\u0435\u0432\u044b\u0435 \u0432\u044b\u0432\u043e\u0434\u044b<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443, \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u044f \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u0445.<\/p><\/li>\n\n\n\n<li><p>\u0418\u0445 \u043f\u0440\u043e\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0441\u0432\u043e\u0434\u0438\u0442 \u043a \u043c\u0438\u043d\u0438\u043c\u0443\u043c\u0443 \u0438\u0437\u043d\u043e\u0441, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044e \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0438 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044e \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438.<\/p><\/li>\n\n\n\n<li><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u044f \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0440\u044f\u0434\u0430, \u0437\u0430\u0449\u0438\u0449\u0430\u044f \u043a\u0430\u043a \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b, \u0442\u0430\u043a \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435.<\/p><\/li>\n\n\n\n<li><p>\u041e\u043d\u0438 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u043c\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u0438 \u0441\u043d\u0438\u0437\u0438\u0442\u044c \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0440\u0430\u0441\u0445\u043e\u0434\u044b.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043b\u0435\u0433\u043a\u043e \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0438\u0445 \u0432 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u0443\u043f\u0440\u043e\u0449\u0430\u044f \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044e.<\/p><\/li>\n\n\n\n<li><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044e \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438, \u043f\u043e\u043c\u043e\u0433\u0430\u044f \u0441\u043d\u0438\u0437\u0438\u0442\u044c \u0440\u0430\u0441\u0445\u043e\u0434\u044b \u043d\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0438 \u0443\u043c\u0435\u043d\u044c\u0448\u0438\u0442\u044c \u0432\u044b\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0442\u0435\u043f\u043b\u0430.<\/p><\/li>\n\n\n\n<li><p>\u042d\u0442\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u043c\u0438, \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0431\u0435\u0437 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0432\u044b\u0431\u0440\u043e\u0441\u043e\u0432 \u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u043c\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b.<\/p><\/li>\n\n\n\n<li><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0438 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0432 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0438 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-advantages-of-vacuum-contactor\">\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0420\u0430\u0431\u043e\u0442\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f | \u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 VCB | \u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 VCB\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/M9RF1RXkD2g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"reliable-performance\">\u041d\u0430\u0434\u0435\u0436\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"consistent-operation\">\u0421\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430<\/h4>\n\n\n\n<p>\u0412\u044b \u043e\u0436\u0438\u0434\u0430\u0435\u0442\u0435, \u0447\u0442\u043e \u0432\u0430\u0448\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0431\u0443\u0434\u0443\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u043e, \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432 \u043d\u0438\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0438 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c\u044e. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u0442\u043e\u043a\u0438 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439 \u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0433\u043e \u0437\u0430\u043f\u0443\u0441\u043a\u0430 \u0438 \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u0430\u0436\u0435 \u0432 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438. \u0420\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435, \u0442\u0430\u043a\u043e\u0435 \u043a\u0430\u043a \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c, \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0441\u043e\u0445\u0440\u0430\u043d\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0443\u043f\u043b\u043e\u0442\u043d\u0435\u043d\u0438\u044f, \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0447\u0435\u043c\u0443 \u0432\u0430\u0448\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0447\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043d\u0435\u043f\u0440\u0435\u0434\u0432\u0438\u0434\u0435\u043d\u043d\u044b\u0445 \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a \u0438 \u0431\u043e\u043b\u044c\u0448\u0443\u044e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"high-durability\">\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0442\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u044c\u044e. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0431\u044b\u0441\u0442\u0440\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c \u0438 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u0438\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u0432\u0430\u0448\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0438 \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u0438\u0445 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c. \u041a \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430\u043c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043e\u0442\u043d\u043e\u0441\u044f\u0442\u0441\u044f \u043d\u0438\u0437\u043a\u043e\u0435 \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435 \u0438 \u0448\u0438\u0440\u043e\u043a\u0430\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e\u0441\u0442\u044c, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u043c\u0438 \u0434\u043b\u044f \u043c\u043d\u043e\u0433\u0438\u0445 \u0442\u0438\u043f\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u041f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u0438 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a \u0432\u044b\u0441\u043e\u043a\u043e \u0446\u0435\u043d\u044f\u0442 \u0438\u0445 \u043e\u0442\u043b\u0438\u0447\u043d\u0443\u044e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u044b\u0441\u0442\u0440\u044b\u0439 \u0440\u0430\u0437\u0440\u044b\u0432 \u0438 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0438 \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u0438\u0445 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f \u0441 \u043d\u0438\u0437\u043a\u0438\u043c \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435\u043c, \u0447\u0442\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0438 \u043f\u043e\u0432\u044b\u0448\u0430\u0435\u0442 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0428\u0438\u0440\u043e\u043a\u0430\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438 \u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b, \u0447\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u043a\u043b\u0438\u0435\u043d\u0442\u043e\u0432<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u043e \u043e\u0446\u0435\u043d\u0435\u043d \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u044f \u043e\u0442\u043b\u0438\u0447\u043d\u0443\u044e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0432 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"long-service-life\">\u0414\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"minimal-contact-erosion\">\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u044d\u0440\u043e\u0437\u0438\u044f \u043f\u0440\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0435<\/h4>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u043b\u043e \u043a\u0430\u043a \u043c\u043e\u0436\u043d\u043e \u0434\u043e\u043b\u044c\u0448\u0435. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u0432\u0430\u043c \u0434\u043e\u0441\u0442\u0438\u0447\u044c \u044d\u0442\u043e\u0439 \u0446\u0435\u043b\u0438, \u0441\u0432\u043e\u0434\u044f \u043a \u043c\u0438\u043d\u0438\u043c\u0443\u043c\u0443 \u044d\u0440\u043e\u0437\u0438\u044e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u0441\u0440\u0435\u0434\u0430 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043e\u043a\u0438\u0441\u043b\u0435\u043d\u0438\u0435 \u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u042d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0432\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u043c\u0435\u043d\u044c\u0448\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u0434\u0435\u043d\u0435\u0433 \u043d\u0430 \u0437\u0430\u043c\u0435\u043d\u0443 \u0434\u0435\u0442\u0430\u043b\u0435\u0439. \u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0441\u0442\u0430\u043d\u043e\u0432\u044f\u0442\u0441\u044f \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u043c\u0438, \u043a\u043e\u0433\u0434\u0430 \u0432\u044b \u0432\u0438\u0434\u0438\u0442\u0435, \u043d\u0430\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u0430\u043b\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u043c\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"reduced-downtime\">\u0421\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u044f<\/h4>\n\n\n\n<p>\u041c\u0435\u043d\u044c\u0448\u0430\u044f \u044d\u0440\u043e\u0437\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043c\u0435\u043d\u044c\u0448\u0435\u043c\u0443 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u0443 \u043f\u043e\u043b\u043e\u043c\u043e\u043a \u0438 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u044f. \u0412\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442\u0435 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0438 \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0438\u0445 \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u043e\u0432. \u041d\u0430 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432\u043b\u0438\u044f\u044e\u0442 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u0432 \u0442\u043e\u043c \u0447\u0438\u0441\u043b\u0435 \u0442\u0438\u043f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u0438 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0424\u0430\u043a\u0442\u043e\u0440<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0435\u0437\u0438\u0441\u0442\u0438\u0432\u043d\u044b\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043c\u0435\u043d\u044c\u0448\u0435 \u043d\u0430\u0433\u0440\u0443\u0436\u0430\u044e\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u044b\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u0441\u043a\u0430\u0447\u043a\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0443\u0445\u0443\u0434\u0448\u0430\u044e\u0442 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u043f\u0440\u0438\u0432\u043e\u0434\u044f\u0442 \u043a \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044e \u0438\u0437\u043d\u043e\u0441\u0430 \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u044d\u0440\u043e\u0437\u0438\u0438, \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u044f \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u043b\u043e\u0432\u0438\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432, \u0430 \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u0438 \u0438 \u043f\u043b\u043e\u0445\u043e\u043c\u0443 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044e.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u0440\u043e\u0434\u043b\u0438\u0442\u044c \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u0448\u0438\u0445 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u044f \u044d\u0442\u0438 \u0444\u0430\u043a\u0442\u043e\u0440\u044b \u0438 \u043f\u0440\u043e\u0432\u043e\u0434\u044f \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u044b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438. \u0422\u0430\u043a\u043e\u0439 \u043f\u043e\u0434\u0445\u043e\u0434 \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u044f \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"electrical-safety-benefits\">\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438<\/h2>\n\n\n\n<p>\u0412\u044b\u0431\u0438\u0440\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b, \u0432\u044b \u043f\u043e\u0432\u044b\u0448\u0430\u0435\u0442\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u0434\u043b\u044f \u0432\u0441\u0435\u0445. \u042d\u0442\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043e\u0431\u043b\u0430\u0434\u0430\u044e\u0442 \u0443\u0441\u043e\u0432\u0435\u0440\u0448\u0435\u043d\u0441\u0442\u0432\u043e\u0432\u0430\u043d\u043d\u044b\u043c\u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u043f\u043e\u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u043a\u0430\u043a \u043b\u044e\u0434\u0435\u0439, \u0442\u0430\u043a \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"arc-suppression\">\u041f\u043e\u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"no-arc-flash-risk\">\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0440\u0438\u0441\u043a\u0430 \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0440\u044f\u0434\u0430<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0443\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0443\u044e \u043a\u0430\u043c\u0435\u0440\u0443 \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0434\u0443\u0433\u0438. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u0437 \u0443\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044f, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0434\u0443\u0433\u0430 \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0438\u043b\u0438 \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0442\u044c\u0441\u044f. \u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a\u0430 \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0434\u0443\u0433\u043e\u0432\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u043c \u0442\u0440\u0430\u0432\u043c\u0430\u043c \u0438\u043b\u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438 \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0433\u0430\u0441\u044f\u0442 \u0434\u0443\u0433\u0443 \u0437\u0430 \u043c\u0438\u043a\u0440\u043e\u0441\u0435\u043a\u0443\u043d\u0434\u044b. \u0422\u0430\u043a\u0430\u044f \u0431\u044b\u0441\u0442\u0440\u0430\u044f \u0440\u0435\u0430\u043a\u0446\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u043e\u043b\u044c\u0448\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u043d\u0430 \u0440\u0430\u0431\u043e\u0447\u0435\u043c \u043c\u0435\u0441\u0442\u0435.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u0445\u0430\u043d\u0438\u0437\u043c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441 \u043f\u043d\u0435\u0432\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u043a\u0430\u043c\u0435\u0440\u0430 \u0431\u044b\u0441\u0442\u0440\u043e \u0433\u0430\u0441\u0438\u0442 \u0434\u0443\u0433\u0443, \u043d\u0435\u0442 \u0438\u043e\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0438\u0446<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043e\u0437\u0434\u0443\u0445 \u043e\u0445\u043b\u0430\u0436\u0434\u0430\u0435\u0442 \u0438 \u0440\u0430\u0437\u0431\u0438\u0432\u0430\u0435\u0442 \u0434\u0443\u0433\u0443, \u043c\u0435\u043d\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u0438\u0441\u0447\u0435\u0437\u043d\u043e\u0432\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0438\u043a\u0440\u043e\u0441\u0435\u043a\u0443\u043d\u0434\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430, \u0431\u043e\u043b\u044c\u0448\u0438\u0439 \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f, \u0431\u044b\u0441\u0442\u0440\u0430\u044f \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435: \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043d\u0438\u0436\u0430\u044e\u0442 \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u044e\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u0412\u044b \u0442\u0430\u043a\u0436\u0435 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u043e\u0442 \u0431\u043e\u043b\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"enhanced-personnel-safety\">\u041f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b\u0430<\/h4>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0441\u0432\u043e\u0435\u0439 \u043a\u043e\u043c\u0430\u043d\u0434\u044b. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u0432 \u044d\u0442\u043e\u043c, \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u044f \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u043e\u0432\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u043d\u0435 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0443\u0442\u0435\u0447\u043a\u0438 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0433\u0430\u0437\u043e\u0432 \u0438\u043b\u0438 \u0433\u043e\u0440\u044f\u0447\u0438\u0445 \u0447\u0430\u0441\u0442\u0438\u0446. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0441 \u0443\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u0441\u0442\u044c\u044e, \u0437\u043d\u0430\u044f, \u0447\u0442\u043e \u0432\u0430\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0441\u0440\u0435\u0434\u0443.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u044b\u0445 \u0434\u0443\u0433 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0438\u0439 \u0440\u0438\u0441\u043a \u043e\u0436\u043e\u0433\u043e\u0432 \u0438\u043b\u0438 \u0442\u0440\u0430\u0432\u043c.<\/p><\/li>\n\n\n\n<li><p>\u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0448\u0443\u043c\u0430 \u0434\u0435\u043b\u0430\u0435\u0442 \u0432\u0430\u0448\u0435 \u0440\u0430\u0431\u043e\u0447\u0435\u0435 \u043c\u0435\u0441\u0442\u043e \u0431\u043e\u043b\u0435\u0435 \u043a\u043e\u043c\u0444\u043e\u0440\u0442\u043d\u044b\u043c.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u0437\u0430\u043a\u0440\u044b\u0442\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0441 \u0442\u043e\u043a\u043e\u0432\u0435\u0434\u0443\u0449\u0438\u043c\u0438 \u0447\u0430\u0441\u0442\u044f\u043c\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"fault-prevention\">\u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"voltage-endurance\">\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0442\u043b\u0438\u0447\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u041e\u043d\u0438 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0431\u0435\u0437 \u043f\u043e\u043b\u043e\u043c\u043e\u043a \u0438 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u0430\u0448\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0431\u044b\u0441\u0442\u0440\u043e \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u043e\u0441\u043b\u0435 \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0447\u0430\u0441\u0442\u043e\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u043d\u0435\u0432\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0442\u043e\u0440\u043c\u043e\u0437\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u041f\u0443\u0442\u0435\u0448\u0435\u0441\u0442\u0432\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u0440\u043e\u0442\u043a\u0438\u0439, \u043f\u0440\u043e\u0441\u0442\u043e\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043b\u0438\u043d\u043d\u044b\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u043e\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0438\u0441\u043a\u0440\u0435\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u044a\u0435\u043c\u043d\u044b\u0435 \u0434\u0443\u0433\u043e\u0432\u044b\u0435 \u0436\u0435\u043b\u043e\u0431\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0435\u0440\u0430\u0442\u0438\u0432\u043d\u044b\u0435 \u0441\u0438\u043b\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0435\u0436\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0427\u0430\u0441\u0442\u043e<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u0440\u0430\u0431\u043e\u0442\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043e 20 \u0440\u0430\u0437 \u0432 \u043c\u0438\u043d\u0443\u0442\u0443<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0443<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>20%-35% \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u0435\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u044c\u0448\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u0448\u0443\u043c\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043d\u0438\u0436\u0435\u043d\u043d\u044b\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0448\u0435<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0432\u044f\u0436\u0438\u0442\u0435\u0441\u044c \u0441 Lifespan<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u043f\u043e\u043b\u0443\u0442\u043e\u0440\u0430 \u043b\u0435\u0442<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0435\u0431\u0443\u0435\u0442 \u0437\u0430\u043c\u0435\u043d\u044b \u0434\u0432\u0430 \u0440\u0430\u0437\u0430 \u0432 \u043c\u0435\u0441\u044f\u0446<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"system-protection\">\u0417\u0430\u0449\u0438\u0442\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/h4>\n\n\n\n<p>\u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0442\u044c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438, \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u043e\u043d\u0438 \u043d\u0430\u043d\u0435\u0441\u0443\u0442 \u0443\u0449\u0435\u0440\u0431. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0442 \u0442\u043e\u043a \u0432\u043d\u0443\u0442\u0440\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043a\u0430\u043c\u0435\u0440\u044b, \u0447\u0442\u043e \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0432\u043e\u0437\u0434\u0443\u0445\u0430 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e\u0432\u044b\u0448\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0432 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445. \u0412\u044b \u0441\u043d\u0438\u0436\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0441\u0431\u043e\u0435\u0432 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u0447\u0442\u043e \u0438\u043c\u0435\u0435\u0442 \u0440\u0435\u0448\u0430\u044e\u0449\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041c\u0435\u043d\u044c\u0448\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0435 \u0448\u0430\u043d\u0441\u043e\u0432 \u0434\u043b\u044f \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p><\/li>\n\n\n\n<li><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f\u043c \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p><\/li>\n\n\n\n<li><p>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432 \u0441\u0435\u0431\u044f \u043b\u0443\u0447\u0448\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u0432\u0441\u0435\u0439 \u0432\u0430\u0448\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0435\u0442\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0412\u044b\u0431\u0438\u0440\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b, \u0432\u044b \u0438\u043d\u0432\u0435\u0441\u0442\u0438\u0440\u0443\u0435\u0442\u0435 \u0432 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043a\u0430\u043a \u043b\u044e\u0434\u0435\u0439, \u0442\u0430\u043a \u0438 \u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-and-cost-savings\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u044f \u0441\u0440\u0435\u0434\u0441\u0442\u0432<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"low-maintenance-needs\">\u041d\u0438\u0437\u043a\u0438\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"fewer-wear-parts\">\u041c\u0435\u043d\u044c\u0448\u0435 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u0435\u043c\u044b\u0445 \u0434\u0435\u0442\u0430\u043b\u0435\u0439<\/h4>\n\n\n\n<p>\u0412\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0431\u0443\u0434\u0435\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0431\u0435\u0437 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u044f. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u0432 \u044d\u0442\u043e\u043c, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432 \u043d\u0438\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043c\u0435\u043d\u044c\u0448\u0435 \u0434\u0432\u0438\u0436\u0443\u0449\u0438\u0445\u0441\u044f \u0438 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u0435\u043c\u044b\u0445 \u0434\u0435\u0442\u0430\u043b\u0435\u0439, \u0447\u0435\u043c \u0432 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u0445. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u043e\u0442 \u043f\u044b\u043b\u0438, \u0433\u0440\u044f\u0437\u0438 \u0438 \u0432\u043b\u0430\u0433\u0438. \u042d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0432\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430\u0445, \u0432\u044b\u0437\u0432\u0430\u043d\u043d\u044b\u0445 \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u0435\u0439 \u0438\u043b\u0438 \u043c\u0443\u0441\u043e\u0440\u043e\u043c. \u0412\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u043c\u0435\u043d\u044c\u0448\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043d\u0430 \u0437\u0430\u043c\u0435\u043d\u0443 \u0438\u0437\u043d\u043e\u0448\u0435\u043d\u043d\u044b\u0445 \u0434\u0435\u0442\u0430\u043b\u0435\u0439, \u0430 \u0432\u0430\u0448\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0434\u043e\u043b\u044c\u0448\u0435 \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f.<\/p><\/li>\n\n\n\n<li><p>\u0422\u0435\u043a\u0443\u0449\u0435\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440, \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441 \u043f\u043d\u0435\u0432\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u0438\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0442\u0438\u0432\u043d\u044b\u0445 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0435\u0439.<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"simplified-upkeep\">\u0423\u043f\u0440\u043e\u0449\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/h4>\n\n\n\n<p>\u0421 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0443\u043f\u0440\u043e\u0441\u0442\u0438\u0442\u044c \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0443 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0447\u0430\u0441\u0442\u044b\u0435 \u0432\u0438\u0437\u0438\u0442\u044b \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u044b\u0445 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u043e\u0432 \u0438\u043b\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0434\u043b\u044f \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430. \u0412 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u0435 \u0441\u043b\u0443\u0447\u0430\u0435\u0432 \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0432\u0438\u0434\u0438\u043c\u044b\u0445 \u043f\u0440\u043e\u0431\u043b\u0435\u043c \u0438 \u0443\u0431\u0435\u0434\u0438\u0442\u044c\u0441\u044f, \u0447\u0442\u043e \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u043c\u0438. \u0422\u0430\u043a\u043e\u0439 \u043f\u043e\u0434\u0445\u043e\u0434 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442 \u0432\u0430\u0448\u0435 \u0432\u0440\u0435\u043c\u044f \u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0432\u0430\u0448\u0435\u0439 \u043a\u043e\u043c\u0430\u043d\u0434\u0435 \u0441\u043e\u0441\u0440\u0435\u0434\u043e\u0442\u043e\u0447\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u0434\u0440\u0443\u0433\u0438\u0445 \u0432\u0430\u0436\u043d\u044b\u0445 \u0437\u0430\u0434\u0430\u0447\u0430\u0445. \u0412 \u043e\u0442\u0440\u0430\u0441\u043b\u044f\u0445, \u0433\u0434\u0435 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u0438\u043c\u0435\u0435\u0442 \u0440\u0435\u0448\u0430\u044e\u0449\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435, \u044d\u0442\u0430 \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u0432\u0430\u0436\u043d\u044b\u043c \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e\u043c.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441\u0432\u043e\u0434\u0438\u0442 \u043a \u043c\u0438\u043d\u0438\u043c\u0443\u043c\u0443 \u0438\u0437\u043d\u043e\u0441, \u0447\u0442\u043e \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432\u0430\u0436\u043d\u043e \u0434\u043b\u044f \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u0441\u0435\u0431\u0435 \u043d\u0435\u043f\u0440\u0435\u0434\u0432\u0438\u0434\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u043e\u0441\u0442\u043e\u0438.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"cost-efficiency\">\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0442\u0440\u0430\u0442<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"lower-maintenance-costs\">\u0421\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/h4>\n\n\n\n<p>\u0412\u044b \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u0435 \u0434\u0435\u043d\u044c\u0433\u0438, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435. \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u043c\u0435\u043d\u0435\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044e \u0437\u0430\u0442\u0440\u0430\u0442 \u0438 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u044f. \u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0441\u0442\u0430\u043d\u043e\u0432\u044f\u0442\u0441\u044f \u043e\u0447\u0435\u0432\u0438\u0434\u043d\u044b\u043c\u0438, \u0435\u0441\u043b\u0438 \u0441\u0440\u0430\u0432\u043d\u0438\u0442\u044c \u0434\u043e\u043b\u0433\u043e\u0441\u0440\u043e\u0447\u043d\u0443\u044e \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u044e \u0441 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0438\u043d\u0432\u0435\u0441\u0442\u0438\u0446\u0438\u044f\u043c\u0438. \u0421\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c \u0432\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u043c\u0435\u043d\u044c\u0448\u0435 \u043d\u0430 \u0440\u0430\u0431\u043e\u0447\u0443\u044e \u0441\u0438\u043b\u0443, \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u0447\u0430\u0441\u0442\u0438 \u0438 \u0430\u0432\u0430\u0440\u0438\u0439\u043d\u044b\u0439 \u0440\u0435\u043c\u043e\u043d\u0442. \u041c\u043d\u043e\u0433\u0438\u0435 \u043e\u0442\u0440\u0430\u0441\u043b\u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u0441\u0447\u0438\u0442\u0430\u044e\u0442, \u0447\u0442\u043e \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u044f \u0437\u0430 \u0441\u0447\u0435\u0442 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u0431\u044b\u0441\u0442\u0440\u043e \u043f\u0435\u0440\u0435\u0432\u0435\u0448\u0438\u0432\u0430\u0435\u0442 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u043c\u0435\u043d\u0435\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044e \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u044f.<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u0435\u0442 \u0438\u0437\u043d\u043e\u0441, \u0447\u0442\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0432\u0430\u0436\u043d\u044b\u043c \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0439, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0445 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b.<\/p><\/li>\n\n\n\n<li><p>\u0414\u043e\u043b\u0433\u043e\u0441\u0440\u043e\u0447\u043d\u0430\u044f \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u044f \u0437\u0430 \u0441\u0447\u0435\u0442 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u0435\u0440\u0435\u0432\u0435\u0441\u0438\u0442\u044c \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0432\u0435\u0441\u0442\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b.<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"reduced-replacement-frequency\">\u0421\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u0437\u0430\u043c\u0435\u043d\u044b<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u043e\u043b\u044c\u0448\u0435, \u0447\u0435\u043c \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b. \u0418\u0445 \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0442\u0430\u043a \u0447\u0430\u0441\u0442\u043e \u0437\u0430\u043c\u0435\u043d\u044f\u0442\u044c, \u0447\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u043e\u0432 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435 \u0438 \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0437\u0430\u043c\u0435\u043d\u0443. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043e\u0442 \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0435 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0431\u044b\u0441\u0442\u0440\u043e. \u0412 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043e\u0442\u0440\u0430\u0441\u043b\u044f\u0445, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043c\u043d\u043e\u0433\u0438\u0445 \u043b\u0435\u0442 \u0431\u0435\u0437 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u044b.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0414\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u044a\u044f\u0441\u043d\u0435\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0438 \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u043e\u0442 \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u0442\u043e \u0441\u0432\u043e\u0434\u0438\u0442 \u043a \u043c\u0438\u043d\u0438\u043c\u0443\u043c\u0443 \u0438\u0437\u043d\u043e\u0441 \u0438 \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043c\u0435\u043d\u0435\u0435 \u0447\u0430\u0441\u0442\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u0435.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u0441\u043b\u0443\u0436\u0438\u0442\u044c \u043c\u043d\u043e\u0433\u043e \u043b\u0435\u0442, \u0447\u0442\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u0432 \u0438\u0445 \u0437\u0430\u043c\u0435\u043d\u0435.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0438\u0437\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u0442\u043a\u0430\u0437\u043e\u0432<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u0442\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043d\u0435\u043f\u0440\u0435\u0434\u0432\u0438\u0434\u0435\u043d\u043d\u044b\u0445 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u0438 \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0441 \u043d\u0438\u043c\u0438 \u0437\u0430\u0442\u0440\u0430\u0442\u044b.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0443\u0432\u0438\u0434\u0435\u0442\u044c \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u0445. \u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0437\u0430\u043c\u0435\u043d\u0430 \u043f\u0443\u0441\u043a\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043c\u043e\u0436\u0435\u0442 \u043e\u043a\u0443\u043f\u0438\u0442\u044c\u0441\u044f \u0437\u0430 \u0441\u0447\u0435\u0442 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0438 \u043d\u0430 \u0437\u0430\u043c\u0435\u043d\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 15 \u043c\u0435\u0441\u044f\u0446\u0435\u0432. \u0412 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u0447\u0442\u043e \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u0435\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0445 \u043f\u0440\u043e\u0432\u0435\u0440\u043e\u043a. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0431\u043e\u043b\u044c\u0448\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0431\u0435\u0437\u043e\u0442\u043a\u0430\u0437\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u0438 \u043c\u0435\u043d\u044c\u0448\u0435 \u0433\u043e\u043b\u043e\u0432\u043d\u043e\u0439 \u0431\u043e\u043b\u0438, \u0447\u0442\u043e \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0432\u0430\u0448\u0435\u043c\u0443 \u0431\u0438\u0437\u043d\u0435\u0441\u0443 \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u044b\u043c.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"energy-efficiency-and-compact-design\">\u042d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/f02e5dc0297c49268233ffe7c0a9d93a.webp\" alt=\"\u042d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\" class=\"wp-image-1548\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/f02e5dc0297c49268233ffe7c0a9d93a.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/f02e5dc0297c49268233ffe7c0a9d93a-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/f02e5dc0297c49268233ffe7c0a9d93a-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/f02e5dc0297c49268233ffe7c0a9d93a-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/f02e5dc0297c49268233ffe7c0a9d93a-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0418\u0441\u0442\u043e\u0447\u043d\u0438\u043a \u0438\u0437\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f: <a target=\"_blank\" rel=\"nofollow noopener\" href=\"https:\/\/pexels.com\">pexels<\/a><\/figcaption><\/figure>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0438\u043c\u0435\u044e\u0449\u0435\u0435\u0441\u044f \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e. \u0418\u0445 \u0443\u0441\u043e\u0432\u0435\u0440\u0448\u0435\u043d\u0441\u0442\u0432\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c, \u0432 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438\u043c\u0435\u044e\u0442 \u043a\u0430\u043a \u043d\u0438\u043a\u043e\u0433\u0434\u0430 \u0432\u0430\u0436\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"efficient-power-switching\">\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"lower-energy-loss\">\u041c\u0435\u043d\u044c\u0448\u0438\u0435 \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0435\u0440\u0438<\/h4>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0440\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043b\u0430 \u044d\u043d\u0435\u0440\u0433\u0438\u044e. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438, \u0447\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0438\u0435 \u043f\u043e\u0442\u0435\u0440\u0438 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b. \u0422\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u044d\u043d\u0435\u0440\u0433\u0438\u0438, \u0442\u0435\u0440\u044f\u0435\u043c\u043e\u0439 \u0432 \u0432\u0438\u0434\u0435 \u0442\u0435\u043f\u043b\u0430 \u0438\u043b\u0438 \u0447\u0435\u0440\u0435\u0437 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435. \u0422\u0430\u043a\u0430\u044f \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0432\u0430\u043c \u0441\u043d\u0438\u0437\u0438\u0442\u044c \u043e\u0431\u0449\u0438\u0435 \u0440\u0430\u0441\u0445\u043e\u0434\u044b \u043d\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0432\u0430\u0448\u0438 \u0443\u0441\u0438\u043b\u0438\u044f \u043f\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044e \u0431\u043e\u043b\u0435\u0435 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442 \u044d\u043d\u0435\u0440\u0433\u0438\u044e, \u043d\u043e \u0438 \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u0435\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u0441\u043d\u0438\u0436\u0430\u044f \u043d\u0435\u043d\u0443\u0436\u043d\u0443\u044e \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043d\u0430 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b.<\/p>\n<\/blockquote>\n\n\n\n<p>\u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u043d\u043e, \u043a\u0430\u043a \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0443\u043b\u0443\u0447\u0448\u0430\u044e\u0442 \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0424\u0430\u043a\u0442\u043e\u0440<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u0430\u044f \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043e\u043f\u0442\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044e \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u0432.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0445 \u0440\u0435\u0448\u0435\u043d\u0438\u0439.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u043e\u0432\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"reduced-heat-generation\">\u0421\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u0434\u0435\u043b\u0435\u043d\u0438\u044f<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0433\u0435\u043d\u0435\u0440\u0438\u0440\u0443\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435 \u0442\u0435\u043f\u043b\u0430 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432\u0435 \u0438\u043b\u0438 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f. \u041c\u0435\u043d\u044c\u0448\u0430\u044f \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0432\u0430\u0448\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0430\u043d\u0435\u043b\u0438 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0445\u043e\u043b\u043e\u0434\u043d\u044b\u043c\u0438, \u0447\u0442\u043e \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0440\u0438\u0441\u043a \u0432\u044b\u0445\u043e\u0434\u0430 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f. \u042d\u0442\u0430 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432\u0430\u0436\u043d\u0430 \u0432 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445, \u0433\u0434\u0435 \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e \u0434\u043b\u044f \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"space-and-weight-advantages\">\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u043f\u043e \u043e\u0431\u044a\u0435\u043c\u0443 \u0438 \u0432\u0435\u0441\u0443<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"compact-size\">\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/h4>\n\n\n\n<p>\u0412 \u0434\u0438\u0441\u043f\u0435\u0442\u0447\u0435\u0440\u0441\u043a\u0438\u0445 \u0438\u043b\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0448\u043a\u0430\u0444\u0430\u0445 \u0447\u0430\u0441\u0442\u043e \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u044e\u0442 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0441 \u043d\u0435\u0445\u0432\u0430\u0442\u043a\u043e\u0439 \u043c\u0435\u0441\u0442\u0430. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0435\u0448\u0430\u044e\u0442 \u044d\u0442\u0443 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0443 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0441\u0432\u043e\u0438\u043c \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u043c \u0440\u0430\u0437\u043c\u0435\u0440\u0430\u043c. \u041e\u043d\u0438 \u0437\u0430\u043d\u0438\u043c\u0430\u044e\u0442 \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u043c\u0435\u043d\u044c\u0448\u0435 \u043c\u0435\u0441\u0442\u0430, \u0447\u0435\u043c \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438. \u0411\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u043c\u0435\u043d\u044c\u0448\u0438\u043c \u0433\u0430\u0431\u0430\u0440\u0438\u0442\u0430\u043c \u0432 \u043e\u0434\u0438\u043d \u0438 \u0442\u043e\u0442 \u0436\u0435 \u043f\u0430\u043d\u0435\u043b\u044c \u0438\u043b\u0438 \u0448\u043a\u0430\u0444 \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0432\u0430\u0448\u0443 \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0431\u043e\u043b\u0435\u0435 \u0433\u0438\u0431\u043a\u043e\u0439 \u0438 \u0433\u043e\u0442\u043e\u0432\u043e\u0439 \u043a \u0431\u0443\u0434\u0443\u0449\u0438\u043c \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f\u043c.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 (VC)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0437\u043c\u0435\u0440 \u0438 \u0432\u0435\u0441<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u044c\u0448\u0438\u0439 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0430\u0437\u043c\u0435\u0440 \u0438 \u0432\u0435\u0441<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u043d\u044c\u0448\u0438\u0439 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0430\u0437\u043c\u0435\u0440 \u0438 \u0432\u0435\u0441<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"lightweight-construction\">\u041b\u0435\u0433\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f<\/h4>\n\n\n\n<p>\u0412\u044b\u0431\u0438\u0440\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b, \u0432\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u043b\u0435\u0433\u043a\u043e\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438. \u0411\u043e\u043b\u0435\u0435 \u043b\u0435\u0433\u043a\u0438\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043f\u0440\u043e\u0449\u0435 \u0432 \u043e\u0431\u0440\u0430\u0449\u0435\u043d\u0438\u0438, \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0435 \u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435. \u042d\u0442\u043e \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442 \u0432\u0440\u0435\u043c\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0438 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0440\u0430\u0431\u043e\u0447\u0443\u044e \u0441\u0438\u043b\u0443. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u0442\u044c \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043f\u0430\u043d\u0435\u043b\u0438 \u0431\u0435\u0437 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0432\u043d\u0435\u0441\u0435\u043d\u0438\u044f \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0442\u0438\u0432\u043d\u044b\u0445 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0439.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u0438 \u043b\u0435\u0433\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u0431\u043b\u0435\u0433\u0447\u0430\u0435\u0442 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0432 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u044f\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p><\/li>\n\n\n\n<li><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043c\u043e\u0436\u043d\u043e \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432 \u0434\u0438\u0441\u043f\u0435\u0442\u0447\u0435\u0440\u0441\u043a\u0438\u0435 \u0438\u043b\u0438 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438 \u0434\u0430\u0436\u0435 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0430.<\/p><\/li>\n\n\n\n<li><p>\u041c\u0435\u043d\u044c\u0448\u0438\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u044b \u0438 \u0432\u0435\u0441 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u043c\u0435\u0441\u0442\u043e \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0438 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0440\u0430\u0441\u0445\u043e\u0434\u044b \u043d\u0430 \u0441\u0442\u0440\u043e\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0440\u0430\u0431\u043e\u0442\u044b.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0432 \u043d\u043e\u0432\u044b\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u0430\u0445 \u0438\u043b\u0438 \u0434\u043b\u044f \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c. \u0418\u0445 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u044d\u043d\u0435\u0440\u0433\u0438\u044e, \u0441\u043d\u0438\u0436\u0430\u0442\u044c \u043d\u0430\u0433\u0440\u0435\u0432 \u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0435 \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e, \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u043e\u0441\u0442\u044c \u0440\u0430\u0431\u043e\u0442\u044b.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"versatility-and-application-range\">\u0423\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0438 \u043e\u0431\u043b\u0430\u0441\u0442\u044c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"flexible-integration\">\u0413\u0438\u0431\u043a\u0430\u044f \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"retrofitting-air-break-contactors\">\u041c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h4>\n\n\n\n<p>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u043e, \u0432\u0430\u043c \u043f\u043e\u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0442\u0430\u0440\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0431\u0435\u0437 \u043f\u043e\u043b\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0434\u0435\u043b\u043a\u0438. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0443\u043f\u0440\u043e\u0449\u0430\u044e\u0442 \u044d\u0442\u043e\u0442 \u043f\u0440\u043e\u0446\u0435\u0441\u0441. \u0418\u0445 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0439 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c \u0432 \u0441\u0442\u0430\u0440\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u044c \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0443\u044e \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044e \u0438 \u0432\u043e\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430\u043c\u0438 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0439. \u0422\u0430\u043a\u043e\u0439 \u043f\u043e\u0434\u0445\u043e\u0434 \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0440\u0430\u0441\u0445\u043e\u0434\u044b \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u0438\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u043f\u0440\u043e\u0441\u0442\u043e\u0438.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0413\u0438\u0431\u043a\u043e\u0441\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u0443\u0441\u0442\u0430\u0440\u0435\u0432\u0448\u0435\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0441 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u043c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c \u0441 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u043f\u0435\u0440\u0435\u0431\u043e\u044f\u043c\u0438 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u043f\u0435\u0440\u0435\u0434\u0435\u043b\u044b\u0432\u0430\u0442\u044c \u0432\u0441\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0438\u043b\u0438 \u043c\u0435\u043d\u044f\u0442\u044c \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f.<\/p>\n<\/blockquote>\n\n\n\n<p>\u041f\u0440\u0438 \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043e\u0434\u0438\u043d \u0438\u0437 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u0445 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u043e\u0432 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u0440\u0438\u0430\u043d\u0442 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0434\u043b\u044f \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u043e\u0437\u0434\u0443\u0445\u0430 \u0432 \u0432\u0430\u043a\u0443\u0443\u043c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043c\u043f\u043b\u0435\u043a\u0442\u044b \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u043c\u043e\u0434\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b IC2814 \u0438\u043b\u0438 IC302 \u0441 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u043c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c \u043d\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0435 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u043e\u0432\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b IC2814 \u0438 IC302.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>ITE 7850 \u041f\u0440\u044f\u043c\u0430\u044f \u0437\u0430\u043c\u0435\u043d\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043f\u0440\u044f\u043c\u0443\u044e \u0437\u0430\u043c\u0435\u043d\u0443 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 ITE 7850 400A \u0431\u0435\u0437 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u0430 \u043c\u0435\u0441\u0442\u0435.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u042d\u0442\u0430 \u0433\u0438\u0431\u043a\u043e\u0441\u0442\u044c \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u0435\u0441\u043a\u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u043c \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044f\u043c \u0438 \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u0435\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u0448\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"use-in-various-systems\">\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u043c\u043d\u043e\u0433\u0438\u0445 \u0442\u0438\u043f\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u0430\u043a \u0432 \u043d\u043e\u0432\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445, \u0442\u0430\u043a \u0438 \u0432 \u0441\u0442\u0430\u0440\u044b\u0445. \u0418\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0438\u0445 \u0432 \u043f\u0430\u043d\u0435\u043b\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u043f\u0443\u0441\u043a\u0430\u0442\u0435\u043b\u0438 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439 \u0438 \u0431\u043b\u043e\u043a\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430\u0445 \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u0438, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0441 \u0448\u0438\u0440\u043e\u043a\u0438\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439 \u0438 \u0441\u0445\u0435\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0434\u0435\u043b\u0430\u044e\u0442 \u0438\u0445 \u0440\u0430\u0437\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u043e\u0431\u044a\u0435\u043a\u0442\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u0442\u0440\u0435\u043c\u044f\u0442\u0441\u044f \u043a \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0431\u0435\u0437 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0439.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"industrial-and-commercial-use\">\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u0438 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"medium-voltage-applications\">\u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0432 \u0441\u0435\u0442\u044f\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432\u043e \u043c\u043d\u043e\u0433\u0438\u0445 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0438 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u0431\u043b\u0430\u0441\u0442\u044f\u0445. \u041e\u043d\u0438 \u0441 \u043b\u0435\u0433\u043a\u043e\u0441\u0442\u044c\u044e \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441 \u0437\u0430\u0434\u0430\u0447\u0430\u043c\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0441\u0440\u0435\u0434\u043d\u0438\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0434\u043b\u044f:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u043c<\/p><\/li>\n\n\n\n<li><p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432<\/p><\/li>\n\n\n\n<li><p>\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/p><\/li>\n\n\n\n<li><p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c\u0438 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0442\u0430\u043a\u0438\u043c\u0438 \u043a\u0430\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438<\/p><\/li>\n\n\n\n<li><p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/p><\/li>\n\n\n\n<li><p>\u041a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u042d\u0442\u0438 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0442 \u0448\u0438\u0440\u043e\u043a\u0438\u0439 \u0441\u043f\u0435\u043a\u0442\u0440 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u0438\u0442\u044c\u0441\u044f \u0438\u043c \u0432 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0438 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c\u0438 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0438 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"modern-system-compatibility\">\u0421\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c \u0441 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c\u0438<\/h4>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043f\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e \u0438 \u0442\u043e\u043a\u0443. \u041e\u043d\u0438 \u043e\u0431\u043b\u0430\u0434\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u044e\u0449\u0435\u0439 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c\u044e, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c\u0441\u044f \u0441 \u0442\u043e\u043a\u0430\u043c\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u0412\u044b \u0442\u0430\u043a\u0436\u0435 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438, \u0447\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0442 \u0434\u043e\u043b\u0433\u043e.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0440\u0430\u0431\u043e\u0447\u0435\u043c\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e \u0432\u0430\u0448\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u043a\u0443\u0449\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0436\u0438\u0434\u0430\u0435\u043c\u044b\u0439 \u0442\u043e\u043a.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0435\u0442 \u0442\u043e\u043a\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u043e \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u043b\u043e\u0432\u0438\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0432 \u0448\u0438\u0440\u043e\u043a\u043e\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440, \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u0438 \u0438 \u0432\u044b\u0441\u043e\u0442\u044b \u043d\u0430\u0434 \u0443\u0440\u043e\u0432\u043d\u0435\u043c \u043c\u043e\u0440\u044f.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0446\u0435\u043d\u043a\u0430 \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0432\u0430\u0448\u0438\u043c \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c \u0441\u0445\u0435\u043c\u0430\u043c \u0437\u0430\u0449\u0438\u0442\u044b \u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041b\u0435\u0433\u043a\u043e \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u043a \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0441 \u0434\u0440\u0443\u0433\u0438\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0441 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u0438 \u0434\u0440\u0443\u0433\u0438\u043c\u0438 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0432\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0435\u0440\u0435\u0434 \u0432\u0432\u043e\u0434\u043e\u043c \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043f\u0440\u043e\u0445\u043e\u0434\u0438\u0442 \u0442\u0449\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u0447\u0442\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043b\u0435\u0433\u043a\u043e \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u044e\u0442\u0441\u044f \u0432 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b. \u0418\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e, \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u0443\u044e \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"environmental-impact\">\u0412\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"eco-friendly-operation\">\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u0430\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"no-harmful-emissions\">\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0432\u044b\u0431\u0440\u043e\u0441\u043e\u0432<\/h4>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u043e\u0432\u0430\u043b\u0438 \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044e \u0431\u043e\u043b\u0435\u0435 \u0447\u0438\u0441\u0442\u043e\u0439 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u0432\u0430\u043c \u0434\u043e\u0441\u0442\u0438\u0447\u044c \u044d\u0442\u043e\u0439 \u0446\u0435\u043b\u0438, \u0440\u0430\u0431\u043e\u0442\u0430\u044f \u0431\u0435\u0437 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0432\u044b\u0431\u0440\u043e\u0441\u043e\u0432. \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u0432 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0442\u0430\u043a\u0438\u0435 \u0432\u0435\u0449\u0435\u0441\u0442\u0432\u0430, \u043a\u0430\u043a \u0433\u0430\u0437 SF6 \u0438\u043b\u0438 \u043c\u0430\u0441\u043b\u043e, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432 \u0438 \u0434\u0435\u043b\u0430\u0435\u0442 \u0432\u0430\u0448\u0435 \u0440\u0430\u0431\u043e\u0447\u0435\u0435 \u043c\u0435\u0441\u0442\u043e \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0435\u0442\u043e\u0434\u044b<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u0442<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u0430 (SF6, \u043c\u0430\u0441\u043b\u043e)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0438 \u043d\u0435 \u0432\u044b\u0434\u0435\u043b\u044f\u044e\u0442 \u043f\u0430\u0440\u043d\u0438\u043a\u043e\u0432\u044b\u0435 \u0433\u0430\u0437\u044b \u0438\u043b\u0438 \u043e\u043f\u0430\u0441\u043d\u044b\u0435 \u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0432\u0435\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b. \u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a\u0430 \u0443\u0442\u0435\u0447\u0435\u043a \u0438 \u0440\u0430\u0437\u043b\u0438\u0432\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u043d\u0430\u043d\u0435\u0441\u0442\u0438 \u0432\u0440\u0435\u0434 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435. \u0421\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u044d\u0440\u043e\u0437\u0438\u0438 \u0442\u0430\u043a\u0436\u0435 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0435 \u043e\u0442\u0445\u043e\u0434\u043e\u0432 \u0438 \u0431\u043e\u043b\u0435\u0435 \u0447\u0438\u0441\u0442\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0441 \u0442\u0435\u0447\u0435\u043d\u0438\u0435\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0438. \u0412\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442\u0435 \u0437\u0430\u0449\u0438\u0442\u0438\u0442\u044c \u0432\u043e\u0437\u0434\u0443\u0445 \u0438 \u043f\u043e\u0447\u0432\u0443 \u0432\u043e\u043a\u0440\u0443\u0433 \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b, \u0432\u044b \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0435 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0438\u043b\u0438\u044f \u043f\u043e \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044e \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u0438 \u043f\u0440\u043e\u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044e \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0430\u043a\u0442\u0438\u043a.<\/p>\n<\/blockquote>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"recyclable-materials\">\u041f\u0435\u0440\u0435\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u043c\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b<\/h4>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u0447\u0442\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u044b \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0432\u0438\u0442\u0438\u044f \u043e\u0442 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0434\u043e \u043e\u043a\u043e\u043d\u0447\u0430\u043d\u0438\u044f \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0440\u0430\u0437\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u044d\u0442\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u043c\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0442\u0445\u043e\u0434\u043e\u0432, \u043f\u043e\u043f\u0430\u0434\u0430\u044e\u0449\u0438\u0445 \u043d\u0430 \u0441\u0432\u0430\u043b\u043a\u0438. \u041c\u043d\u043e\u0433\u0438\u0435 \u0434\u0435\u0442\u0430\u043b\u0438, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u043c\u0435\u0442\u0430\u043b\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438 \u043a\u043e\u0440\u043f\u0443\u0441\u0430, \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u044b \u0438\u043b\u0438 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u044b \u0432 \u043d\u043e\u0432\u044b\u0445 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430\u0445.<\/p>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0447\u0430\u0441\u0442\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0438 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c. \u0412\u0435\u0434\u0443\u0449\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0441\u043e\u0431\u043b\u044e\u0434\u0430\u044e\u0442 \u0432\u0430\u0436\u043d\u044b\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b, \u0432 \u0442\u043e\u043c \u0447\u0438\u0441\u043b\u0435:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>RoHS (\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432)<\/p><\/li>\n\n\n\n<li><p>REACH (\u0420\u0435\u0433\u0438\u0441\u0442\u0440\u0430\u0446\u0438\u044f, \u043e\u0446\u0435\u043d\u043a\u0430, \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432)<\/p><\/li>\n\n\n\n<li><p>ISO 9001 (\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e\u043c)<\/p><\/li>\n\n\n\n<li><p>ISO 14001 (\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043c\u0435\u043d\u0435\u0434\u0436\u043c\u0435\u043d\u0442)<\/p><\/li>\n\n\n\n<li><p>CE (\u0435\u0432\u0440\u043e\u043f\u0435\u0439\u0441\u043a\u043e\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435)<\/p><\/li>\n\n\n\n<li><p>\u041c\u042d\u041a (\u041c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u0430\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u043e\u043c\u0438\u0441\u0441\u0438\u044f)<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u042d\u0442\u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442, \u0447\u0442\u043e \u0432\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u043e\u0435 \u0441 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435\u043c \u043d\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443. \u0412\u044b \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044e \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432 \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0435 \u0446\u0438\u0440\u043a\u0443\u043b\u044f\u0440\u043d\u0443\u044e \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u043a\u0443, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u044d\u0442\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c.<\/p>\n\n\n\n<p>\u0412\u044b \u0442\u0430\u043a\u0436\u0435 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e \u0432 \u0432\u0438\u0434\u0435 \u0431\u043e\u043b\u0435\u0435 \u0447\u0438\u0441\u0442\u043e\u0433\u043e \u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0430. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u044f\u0442 \u0434\u044b\u043c\u0430, \u043f\u0430\u0440\u043e\u0432 \u0438\u043b\u0438 \u043e\u0441\u0442\u0430\u0442\u043a\u043e\u0432 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f. \u0412\u044b \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0435\u0442\u0435 \u0447\u0438\u0441\u0442\u043e\u0442\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u0440\u0438\u043b\u0435\u0433\u0430\u044e\u0449\u0438\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0449\u0435 \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0435\u0435 \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0439 \u043a\u043e\u043c\u0430\u043d\u0434\u044b.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435: \u0412\u044b\u0431\u0438\u0440\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b, \u0432\u044b \u0434\u0435\u043b\u0430\u0435\u0442\u0435 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u043a\u0430\u043a \u0434\u043b\u044f \u0441\u0432\u043e\u0435\u0433\u043e \u0431\u0438\u0437\u043d\u0435\u0441\u0430, \u0442\u0430\u043a \u0438 \u0434\u043b\u044f \u043f\u043b\u0430\u043d\u0435\u0442\u044b. \u0412\u044b \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442\u0435 \u0432\u044b\u0431\u0440\u043e\u0441\u044b, \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u0435\u0442\u0435 \u043e\u0442\u0445\u043e\u0434\u044b \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0435 \u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-choose-vacuum-contactors-now\">\u041f\u043e\u0447\u0435\u043c\u0443 \u0441\u0442\u043e\u0438\u0442 \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u043c\u0435\u043d\u043d\u043e \u0441\u0435\u0439\u0447\u0430\u0441<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"meeting-industry-needs\">\u0423\u0434\u043e\u0432\u043b\u0435\u0442\u0432\u043e\u0440\u0435\u043d\u0438\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0435\u0439 \u0438\u043d\u0434\u0443\u0441\u0442\u0440\u0438\u0438<\/h3>\n\n\n\n<p>\u0421\u0435\u0433\u043e\u0434\u043d\u044f \u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043e\u0442\u0440\u0430\u0441\u043b\u0438 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u044f\u0442 \u043c\u043d\u043e\u0433\u043e\u0447\u0438\u0441\u043b\u0435\u043d\u043d\u044b\u0435 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f. \u041a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 \u043d\u0443\u0436\u0434\u0430\u044e\u0442\u0441\u044f \u0432 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0445, \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0445 \u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0445 \u0440\u0435\u0448\u0435\u043d\u0438\u044f\u0445. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0442\u0432\u0435\u0447\u0430\u044e\u0442 \u044d\u0442\u0438\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0438 \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u0438\u0434\u0442\u0438 \u0432 \u043d\u043e\u0433\u0443 \u0441 \u043d\u043e\u0432\u044b\u043c\u0438 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u044f\u043c\u0438. \u0412\u044b \u0437\u0430\u043c\u0435\u0447\u0430\u0435\u0442\u0435 \u0440\u043e\u0441\u0442 \u0447\u0438\u0441\u043b\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438, \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044e \u0441\u0442\u0430\u0440\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c \u0438 \u0441\u0442\u0440\u0435\u043c\u043b\u0435\u043d\u0438\u0435 \u043a \u0431\u043e\u043b\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u043c\u0443 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u044d\u0442\u0438\u043c \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c.<\/p>\n\n\n\n<p>\u0412\u043e\u0442 \u043f\u043e\u0447\u0435\u043c\u0443 \u0442\u0435\u043a\u0443\u0449\u0438\u0435 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0438 \u0432 \u043e\u0442\u0440\u0430\u0441\u043b\u0438 \u0434\u0435\u043b\u0430\u044e\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0437\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u044f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u043b\u0438\u044f\u043d\u0438\u0435 \u043d\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u043e\u0441\u0442 \u0441\u0435\u043a\u0442\u043e\u0440\u0430 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0441\u043f\u0440\u043e\u0441\u0430 \u043d\u0430 \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0434\u043b\u044f \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0445, \u0432\u0435\u0442\u0440\u043e\u0432\u044b\u0445 \u0438 \u0433\u0438\u0434\u0440\u043e\u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u0439.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u0434\u043e\u0432\u044b\u0445 \u0440\u0435\u0448\u0435\u043d\u0438\u0439, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b, \u0432 \u0441\u0432\u044f\u0437\u0438 \u0441\u043e \u0441\u0442\u0430\u0440\u0435\u043d\u0438\u0435\u043c \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043f\u0440\u043e\u0441 \u043d\u0430 \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u043b\u0443\u0447\u0448\u0435\u043d\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u0438\u0445 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u044e \u0432 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0445\u043e\u0437\u044f\u0439\u0441\u0442\u0432\u0435 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0421\u043e\u0432\u0435\u0442: \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0432 \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445, \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0445 \u0442\u0443\u0440\u0431\u0438\u043d\u0430\u0445 \u0438 \u0433\u0438\u0434\u0440\u043e\u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445. \u042d\u0442\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"compliance-with-standards\">\u0421\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"compliance-with-standards\">\u0421\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432<\/h4>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u043b\u043e \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u0434\u043e\u0441\u0442\u0438\u0447\u044c \u044d\u0442\u0438\u0445 \u0446\u0435\u043b\u0435\u0439. \u041e\u043d\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u0433\u0430\u0448\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u0438 \u0434\u043b\u044f \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044f \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043a \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u043c \u0441\u0435\u0442\u044f\u043c, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442 \u0432\u0430\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0432\u043e\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u0431\u044b\u0441\u0442\u0440\u043e \u0440\u0435\u0430\u0433\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043d\u0430 \u043b\u044e\u0431\u044b\u0435 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u044b\u0441\u0442\u0440\u043e\u0435 \u043f\u043e\u0433\u0430\u0448\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u0435\u0442 \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0441 \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0441\u0435\u0442\u044f\u043c\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0432\u044b\u0448\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043e\u0441\u0443\u0449\u0435\u0441\u0442\u0432\u043b\u044f\u0442\u044c \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0434\u043e\u043b\u0433\u043e\u0441\u0440\u043e\u0447\u043d\u0443\u044e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u043f\u0440\u043e\u0447\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u043c\u0435\u0434\u044c-\u0432\u0438\u0441\u043c\u0443\u0442, \u0441\u0435\u0440\u0435\u0431\u0440\u043e-\u0432\u0438\u0441\u043c\u0443\u0442, \u0441\u0435\u0440\u0435\u0431\u0440\u043e-\u0441\u0432\u0438\u043d\u0435\u0446 \u0438 \u043c\u0435\u0434\u044c-\u0441\u0432\u0438\u043d\u0435\u0446. \u042d\u0442\u0438 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u043f\u0440\u043e\u0434\u043b\u0438\u0442\u044c \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0443\u043b\u0443\u0447\u0448\u0438\u0442\u044c \u0435\u0433\u043e \u0440\u0430\u0431\u043e\u0442\u0443. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u0447\u0442\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0438\u043c \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0432\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u0441\u043b\u0430\u0432\u0438\u0442\u0441\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c\u044e \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c\u044e \u043f\u0440\u0435\u0432\u043e\u0441\u0445\u043e\u0434\u0438\u0442\u044c \u043b\u044e\u0431\u044b\u0435 \u043e\u0436\u0438\u0434\u0430\u043d\u0438\u044f \u043f\u043e \u0441\u0440\u043e\u043a\u0443 \u0441\u043b\u0443\u0436\u0431\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u0443\u0442\u044c \u0432 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"future-proof-solutions\">\u0420\u0435\u0448\u0435\u043d\u0438\u044f, \u0433\u043e\u0442\u043e\u0432\u044b\u0435 \u043a \u0431\u0443\u0434\u0443\u0449\u0435\u043c\u0443<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"future-proof-solutions\">\u0420\u0435\u0448\u0435\u043d\u0438\u044f, \u0433\u043e\u0442\u043e\u0432\u044b\u0435 \u043a \u0431\u0443\u0434\u0443\u0449\u0435\u043c\u0443<\/h4>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0438 \u0438\u043d\u0432\u0435\u0441\u0442\u0438\u0446\u0438\u0438 \u0431\u044b\u043b\u0438 \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u044b\u043c\u0438. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0432\u0430\u043c \u043f\u0435\u0440\u0441\u043f\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0432\u0430\u0448\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0442\u0430\u0440\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438\u043b\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u043d\u043e\u0432\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u043d\u0435 \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u044f\u0441\u044c \u043e\u0431 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432 \u0438\u043b\u0438 \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u0438 \u043d\u043e\u0432\u044b\u0445 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0439. \u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0441 \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0441\u0435\u0442\u044f\u043c\u0438 \u0438 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u043c\u0438 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430\u043c\u0438 \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u043d\u0438\u0445 \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u043c\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\u043c\u0438 \u0438 \u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u044b\u043c\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f\u043c\u0438 \u043f\u043e \u043c\u0435\u0440\u0435 \u0440\u043e\u0441\u0442\u0430 \u0432\u0430\u0448\u0438\u0445 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043b\u0435\u0433\u043a\u043e \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u043f\u0430\u043d\u0435\u043b\u044f\u0445.<\/p><\/li>\n\n\n\n<li><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0438\u0445 \u0432 \u043d\u043e\u0432\u044b\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u0430\u0445, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0445 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430.<\/p><\/li>\n\n\n\n<li><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0438\u0445 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c\u0443 \u0441\u0440\u043e\u043a\u0443 \u0441\u043b\u0443\u0436\u0431\u044b \u0438 \u043d\u0438\u0437\u043a\u0438\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u043a \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f \u0432\u043f\u0435\u0440\u0435\u0434\u0438 \u0432 \u043c\u0435\u043d\u044f\u044e\u0449\u0435\u0439\u0441\u044f \u043e\u0442\u0440\u0430\u0441\u043b\u0438. \u0412\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u0441\u0435\u0433\u043e\u0434\u043d\u044f\u0448\u043d\u0438\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0438 \u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u0441\u044c \u043a \u0437\u0430\u0432\u0442\u0440\u0430\u0448\u043d\u0438\u043c \u0432\u044b\u0437\u043e\u0432\u0430\u043c.<\/p>\n\n\n\n<p>\u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u043e \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b. \u042d\u0442\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043e\u0442\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c\u044e, \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c\u044e \u0438 \u043d\u0438\u0437\u043a\u0438\u043c\u0438 \u0437\u0430\u0442\u0440\u0430\u0442\u0430\u043c\u0438 \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435. \u0412\u044b \u043f\u043e\u0432\u044b\u0448\u0430\u0435\u0442\u0435 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u0432\u043e\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u0438 \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044e \u0446\u0435\u043b\u0435\u0439 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0412\u043b\u0438\u044f\u043d\u0438\u0435 \u043d\u0430 \u0432\u0430\u0448\u0443 \u0441\u0438\u0441\u0442\u0435\u043c\u0443<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043d\u043e\u043c\u0438\u0442 \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0437\u0430\u0442\u0440\u0430\u0442\u044b<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043b\u044e\u0434\u0435\u0439 \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u044f \u0438 \u0440\u0435\u043c\u043e\u043d\u0442\u043e\u0432<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0434\u0435\u044f\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0443\u0434\u0443\u0449\u0435\u0435 \u0441\u0432\u043e\u0435\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430 \u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c. \u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u0440\u0438 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0439 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u0438\u0437\u0443\u0447\u0438\u0442\u0435 \u0431\u043e\u043b\u0435\u0435 \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0432\u0430\u0448\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0443\u0436\u0434.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-a-vacuum-contactor\">\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/\" data-type=\"page\" data-id=\"1186\">\u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/a>?<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u2014 \u044d\u0442\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u0432 \u043a\u043e\u0442\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0442\u043e\u043a\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0439 \u0432\u0430\u043a\u0443\u0443\u043c. \u041e\u043d \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0438 \u0434\u0440\u0443\u0433\u0438\u043c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435\u043c. \u0412\u0430\u043a\u0443\u0443\u043c \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438, \u0447\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-long-does-a-vacuum-contactor-last\">\u0421\u043a\u043e\u043b\u044c\u043a\u043e \u0441\u043b\u0443\u0436\u0438\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440?<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0442 \u0432\u0430\u043c \u043c\u043d\u043e\u0433\u043e \u043b\u0435\u0442. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u0411\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u043e\u0442\u043c\u0435\u0447\u0430\u044e\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0431\u043e\u043b\u0435\u0435 1 \u043c\u0438\u043b\u043b\u0438\u043e\u043d\u0430 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u0440\u0438 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-you-retrofit-vacuum-contactors-into-old-systems\">\u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432 \u0441\u0442\u0430\u0440\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445?<\/h3>\n\n\n\n<p>\u0414\u0430, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u0432 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043f\u0430\u043d\u0435\u043b\u0438. \u0418\u0445 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440 \u0438 \u0433\u0438\u0431\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0443\u043f\u0440\u043e\u0449\u0430\u044e\u0442 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044e. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u043c\u0435\u043d\u044f\u0442\u044c \u0432\u0441\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443, \u0447\u0442\u043e\u0431\u044b \u0432\u043e\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430\u043c\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"do-vacuum-contactors-need-much-maintenance\">\u0422\u0440\u0435\u0431\u0443\u044e\u0442 \u043b\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f?<\/h3>\n\n\n\n<p>\u0421 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438 \u0432\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u043c\u0435\u043d\u044c\u0448\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0435 \u0434\u0435\u0442\u0430\u043b\u0438 \u043e\u0442 \u043f\u044b\u043b\u0438 \u0438 \u0432\u043b\u0430\u0433\u0438. \u0412\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u043f\u0440\u043e\u0441\u0442\u044b\u0435 \u043e\u0441\u043c\u043e\u0442\u0440\u044b \u0438 \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"are-vacuum-contactors-safe-for-people\">\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b \u043b\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u043b\u044e\u0434\u0435\u0439?<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u043c \u0438 \u0432\u0430\u0448\u0435\u0439 \u043a\u043e\u043c\u0430\u043d\u0434\u0435. \u0413\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u0430\u044f \u043a\u0430\u043c\u0435\u0440\u0430 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u043e\u0432\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432 \u0438 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0432\u044b\u0431\u0440\u043e\u0441\u043e\u0432. \u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u043e\u0436\u043e\u0433\u043e\u0432, \u0442\u0440\u0430\u0432\u043c \u0438 \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u044b\u0445 \u0433\u0430\u0437\u043e\u0432.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"where-do-you-use-vacuum-contactors\">\u0413\u0434\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b?<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432\u043e \u043c\u043d\u043e\u0433\u0438\u0445 \u043c\u0435\u0441\u0442\u0430\u0445. \u041e\u043d\u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u043d\u0430 \u0437\u0430\u0432\u043e\u0434\u0430\u0445, \u0432 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u0437\u0434\u0430\u043d\u0438\u044f\u0445, \u043d\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u0438 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u0421 \u0438\u0445 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043c\u043e\u0436\u043d\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u0442\u044c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u043c\u0438 \u0431\u0430\u0442\u0430\u0440\u0435\u044f\u043c\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-vacuum-contactors-help-the-environment\">\u041a\u0430\u043a \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435?<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u0440\u0435\u0434\u043d\u044b\u0435 \u0433\u0430\u0437\u044b \u0438\u043b\u0438 \u043c\u0430\u0441\u043b\u0430. \u0412\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442\u0435 \u0441\u043d\u0438\u0437\u0438\u0442\u044c \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u0438 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0442\u0445\u043e\u0434\u043e\u0432. \u041c\u043d\u043e\u0433\u0438\u0435 \u0434\u0435\u0442\u0430\u043b\u0438 \u043f\u043e\u0434\u043b\u0435\u0436\u0430\u0442 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u043a\u0435, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044e \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-makes-vacuum-contactors-energy-efficient\">\u0427\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u043c\u0438?<\/h3>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u043f\u0438\u0442\u0430\u043d\u0438\u0435 \u0441 \u043c\u0435\u043d\u044c\u0448\u0438\u043c\u0438 \u043f\u043e\u0442\u0435\u0440\u044f\u043c\u0438 \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u0412\u044b \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u0435 \u043d\u0430 \u0441\u0447\u0435\u0442\u0430\u0445 \u0437\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442\u0435 \u043d\u0430\u0433\u0440\u0435\u0432 \u043f\u0430\u043d\u0435\u043b\u0435\u0439. \u0422\u0430\u043a\u0430\u044f \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u0435\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0420\u0435\u0441\u0443\u0440\u0441\u044b \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u0431\u043e\u0440\u0430<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/ckg-vacuum-contactor\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 CKG<\/a> \u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0438 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u044f \u043f\u043e \u0432\u0432\u043e\u0434\u0443 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/li>\n\n\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/high-voltage-vacuum-contactor-lcz-series\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 Lcz<\/a> ? \u041b\u043e\u0433\u0438\u043a\u0430 \u0432\u044b\u0431\u043e\u0440\u0430 \u0438 \u0434\u0435\u0442\u0430\u043b\u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0441\u0431\u043e\u0435\u0432<\/li>\n\n\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/jcz-vacuum-contactor\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 jcz<\/a> ? \u041c\u043e\u0434\u0435\u043b\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0438 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043f\u0440\u0438\u0435\u043c\u043a\u0438<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b, \u043d\u0438\u0437\u043a\u0438\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0434\u043b\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>","protected":false},"author":3,"featured_media":1547,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-1549","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1549","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=1549"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1549\/revisions"}],"predecessor-version":[{"id":3658,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1549\/revisions\/3658"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/1547"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=1549"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=1549"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=1549"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}