{"id":1579,"date":"2025-11-29T20:27:40","date_gmt":"2025-11-29T20:27:40","guid":{"rendered":"https:\/\/xbrele.com\/what-is-dry-type-transformer-and-how-does-it-work\/"},"modified":"2026-04-07T15:09:25","modified_gmt":"2026-04-07T15:09:25","slug":"what-is-dry-type-transformer-and-how-does-it-work","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/what-is-dry-type-transformer-and-how-does-it-work\/","title":{"rendered":"\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0438 \u043a\u0430\u043a \u043e\u043d \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1408\" height=\"768\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/c61efc2c2c8442f790d574b9a81e35f5.jpg\" alt=\"\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0438 \u043a\u0430\u043a \u043e\u043d \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442\" class=\"wp-image-1578\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/c61efc2c2c8442f790d574b9a81e35f5.jpg 1408w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/c61efc2c2c8442f790d574b9a81e35f5-300x164.jpg 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/c61efc2c2c8442f790d574b9a81e35f5-1024x559.jpg 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/c61efc2c2c8442f790d574b9a81e35f5-768x419.jpg 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/11\/c61efc2c2c8442f790d574b9a81e35f5-18x10.jpg 18w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/figure>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0437\u0430\u0434\u0430\u0442\u044c\u0441\u044f \u0432\u043e\u043f\u0440\u043e\u0441\u043e\u043c, \u0447\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u0412 \u044d\u0442\u043e\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0435 \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0433\u0430\u0437 \u0432\u043c\u0435\u0441\u0442\u043e \u043c\u0430\u0441\u043b\u0430. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0439 \u0432\u0430\u0440\u0438\u0430\u043d\u0442 \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432\u043d\u0443\u0442\u0440\u0438 \u043d\u0435\u0442 \u043b\u0435\u0433\u043a\u043e\u0432\u043e\u0441\u043f\u043b\u0430\u043c\u0435\u043d\u044f\u044e\u0449\u0435\u0433\u043e\u0441\u044f \u043c\u0430\u0441\u043b\u0430. \u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0445\u043e\u043b\u043e\u0434\u043d\u044b\u043c\u0438 \u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432 \u0437\u0430\u043a\u0440\u044b\u0442\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041e\u043d\u0438 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b \u043a \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044e \u043e\u0433\u043d\u044f, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0438\u0437 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u043e\u0439 \u0441\u043c\u043e\u043b\u044b \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0441\u0430\u043c\u043e\u0437\u0430\u0442\u0443\u0445\u0430\u044e\u0449\u0435\u0439.<\/p><\/li><li><p>\u041e\u043d\u0438 \u043d\u0435 \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u044e\u0442 \u0432\u0440\u0435\u0434\u043d\u044b\u0435 \u043c\u0430\u0441\u043b\u0430, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u043f\u043e\u0447\u0432\u044b \u0438 \u0432\u043e\u0434\u044b.<\/p><\/li><li><p>\u0412\u044b \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0435 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u044d\u0442\u0443 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044e.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u041a\u043b\u044e\u0447\u0435\u0432\u044b\u0435 \u0432\u044b\u0432\u043e\u0434\u044b<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0433\u0430\u0437 \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438, \u0447\u0435\u043c \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b.<\/p><\/li><li><p>\u041e\u043d\u0438 \u043e\u0433\u043d\u0435\u0441\u0442\u043e\u0439\u043a\u0438\u0435 \u0438 \u043d\u0435 \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u044e\u0442 \u0432\u0440\u0435\u0434\u043d\u044b\u0435 \u043c\u0430\u0441\u043b\u0430, \u0447\u0442\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0440\u0438\u0441\u043a\u0438 \u0434\u043b\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0435.<\/p><\/li><li><p>\u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f\u043c \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u0438 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430.<\/p><\/li><li><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0432 \u0442\u0430\u043a\u0438\u0445 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0440\u0435\u0434\u0430\u0445, \u043a\u0430\u043a \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u044b \u0438 \u0448\u043a\u043e\u043b\u044b.<\/p><\/li><li><p>\u041e\u043d\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0435 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u043c\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438 \u0438\u0437\u0431\u0435\u0433\u0430\u044f \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u044b\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432.<\/p><\/li><li><p>\u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0434\u0430\u0436\u0435 \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445, \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u044f \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c.<\/p><\/li><li><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0441\u043f\u043e\u043a\u043e\u0439\u0441\u0442\u0432\u0438\u0435 \u043f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u0432 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445.<\/p><\/li><li><p>\u0412\u044b\u0431\u043e\u0440 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442 \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044e \u0446\u0435\u043b\u0435\u0439 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0432\u0438\u0442\u0438\u044f \u0438 \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0437\u0430\u0449\u0438\u0442\u0438\u0442\u044c \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-rich is-provider-embed-handler wp-block-embed-embed-handler wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430? Eaton \u043e\u0431\u044a\u044f\u0441\u043d\u044f\u0435\u0442\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/Y49T_GEODVM?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0438 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h3>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u0432\u044b \u0441\u043f\u0440\u0430\u0448\u0438\u0432\u0430\u0435\u0442\u0435, \u0447\u0442\u043e \u0442\u0430\u043a\u043e\u0435 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0441\u0443\u0445\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440<\/a>, \u0412\u044b \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u0435\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0438\u0437\u043c\u0435\u043d\u044f\u0435\u0442 \u0443\u0440\u043e\u0432\u043d\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0431\u0435\u0437 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u0430\u0441\u043b\u0430 \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438. \u0412\u043c\u0435\u0441\u0442\u043e \u044d\u0442\u043e\u0433\u043e \u043e\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0433\u0430\u0437\u044b. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0435\u0433\u043e \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c \u0438 \u043f\u0440\u043e\u0441\u0442\u044b\u043c \u0432 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u0432\u043e \u043c\u043d\u043e\u0433\u0438\u0445 \u043c\u0435\u0441\u0442\u0430\u0445, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0442\u0430\u043c, \u0433\u0434\u0435 \u0432\u0430\u0436\u043d\u0430 \u043f\u043e\u0436\u0430\u0440\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c.<\/p>\n\n\n\n<p>\u0412\u044b \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0442\u0435, \u0447\u0442\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0432\u044b\u0434\u0435\u043b\u044f\u044e\u0442\u0441\u044f \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0441\u0432\u043e\u0438\u043c \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c. \u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u0438\u0445 \u043e\u0442\u043b\u0438\u0447\u0438\u044f \u043e\u0442 \u0434\u0440\u0443\u0433\u0438\u0445 \u0442\u0438\u043f\u043e\u0432 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u0442\u044c \u044d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0443\u0441\u0438\u043b\u0438\u044f\u043c\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043f\u0440\u0435\u0432\u0437\u043e\u0439\u0434\u0435\u043d\u043d\u0430\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u043d\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432 \u043a \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044e \u0432\u043e\u0434\u044b \u0438 \u043d\u0435\u0431\u043b\u0430\u0433\u043e\u043f\u0440\u0438\u044f\u0442\u043d\u044b\u0445 \u043f\u043e\u0433\u043e\u0434\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u0435\u0437 \u043e\u043f\u0430\u0441\u0435\u043d\u0438\u0439 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0438\u0445 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435 \u0438\u043b\u0438 \u0432\u043e \u0432\u043b\u0430\u0436\u043d\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0438\u0445 \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0435\u0440\u0435\u0434\u043e\u0432\u044b\u0435 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u043e\u0432\u0435\u0440\u0448\u0435\u043d\u0441\u0442\u0432\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u043a\u0430\u043a \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u0442\u0430\u043a \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0438\u0437\u0430\u0439\u043d<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435 \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u043f\u0440\u0438\u0433\u043e\u0434\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u043c\u043d\u043e\u0433\u0438\u0445 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0433\u043d\u0435\u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0435 \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u043d\u0438 \u0438\u043c\u0435\u044e\u0442 \u043d\u0438\u0437\u043a\u0438\u0439 \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f, \u0447\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u043e\u043b\u044c\u0448\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0432\u0430\u0436\u043d\u044b \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041b\u0438\u0442\u0430\u044f \u0441\u043c\u043e\u043b\u0430 \u0438 \u0442\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f<\/h3>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0437\u0430\u0434\u0430\u0442\u044c\u0441\u044f \u0432\u043e\u043f\u0440\u043e\u0441\u043e\u043c, \u043a\u0430\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u043c\u0438. \u041e\u0442\u0432\u0435\u0442 \u043a\u0440\u043e\u0435\u0442\u0441\u044f \u0432 \u0438\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0438\u0437 \u043b\u0438\u0442\u043e\u0439 \u0441\u043c\u043e\u043b\u044b \u0438 \u0442\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u043b\u0438\u0442\u0443\u044e \u0441\u043c\u043e\u043b\u0443 \u0434\u043b\u044f \u043f\u043e\u043a\u0440\u044b\u0442\u0438\u044f \u043e\u0431\u043c\u043e\u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430. \u042d\u0442\u0430 \u0441\u043c\u043e\u043b\u0430 \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442 \u043a\u0430\u043a \u043f\u0440\u043e\u0447\u043d\u044b\u0439 \u0449\u0438\u0442, \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0449\u0438\u0439 \u043e\u0442 \u0432\u043b\u0430\u0433\u0438, \u043f\u044b\u043b\u0438 \u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0439.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0437 \u043b\u0438\u0442\u043e\u0439 \u0441\u043c\u043e\u043b\u044b \u043d\u0435 \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u044e\u0442 \u0432\u043b\u0430\u0433\u0443 \u0432\u043d\u0443\u0442\u0440\u044c. \u042d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0438\u0445 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0432\u043e \u0432\u043b\u0430\u0436\u043d\u044b\u0445 \u0438\u043b\u0438 \u043c\u043e\u043a\u0440\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445.<\/p><\/li><li><p>\u0421\u043c\u043e\u043b\u0430 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0441\u0430\u043c\u043e\u0437\u0430\u0442\u0443\u0445\u0430\u044e\u0449\u0435\u0439. \u0412 \u0441\u043b\u0443\u0447\u0430\u0435 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u043e\u043d\u0430 \u0441\u0430\u043c\u043e\u0437\u0430\u0442\u0443\u0445\u0430\u0435\u0442 \u0438 \u0432\u044b\u0434\u0435\u043b\u044f\u0435\u0442 \u043e\u0447\u0435\u043d\u044c \u043c\u0430\u043b\u043e \u0434\u044b\u043c\u0430.<\/p><\/li><li><p>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0432\u0430\u0441 \u043e\u0442 \u043f\u043e\u0440\u0430\u0436\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0442\u043e\u043a\u043e\u043c \u0438 \u0443\u043b\u0443\u0447\u0448\u0430\u0435\u0442 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c.<\/p><\/li><li><p>\u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0442\u0440\u0430\u0442\u0438\u0442\u044c \u043c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u0434\u0435\u043d\u0435\u0433 \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435.<\/p><\/li><li><p>\u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0445\u043e\u0440\u043e\u0448\u043e \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u043e\u043b\u044c\u0448\u0435, \u0434\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u0447\u0442\u043e-\u0442\u043e \u043f\u043e\u0439\u0434\u0435\u0442 \u043d\u0435 \u0442\u0430\u043a.<\/p><\/li><li><p>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u043c\u0438, \u0447\u0442\u043e \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442 \u0437\u0430\u0449\u0438\u0442\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b.<\/p><\/li><li><p>\u041e\u043d\u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0431\u044b\u0441\u0442\u0440\u043e\u043c \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b.<\/p><\/li><li><p>\u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0442\u0430\u043a\u0438\u0445 \u043f\u0440\u043e\u0431\u043b\u0435\u043c, \u043a\u0430\u043a \u0447\u0430\u0441\u0442\u0438\u0447\u043d\u044b\u0435 \u0440\u0430\u0437\u0440\u044f\u0434\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u0441\u0431\u043e\u044f\u043c.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0437 \u043b\u0438\u0442\u043e\u0439 \u0441\u043c\u043e\u043b\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438, \u0442\u0430\u043a\u0438\u043c \u043a\u0430\u043a IS 11171 \u0438 IEC 60076-11. \u042d\u0442\u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u043e\u0437\u043d\u0430\u0447\u0430\u044e\u0442, \u0447\u0442\u043e \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0438\u043c \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u043f\u043e\u0436\u0430\u0440\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u044b, \u0448\u043a\u043e\u043b\u044b \u0438 \u0444\u0430\u0431\u0440\u0438\u043a\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0412\u043e\u0437\u0434\u0443\u0448\u043d\u0430\u044f \u0438 \u0433\u0430\u0437\u043e\u0432\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/h3>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u043f\u0440\u043e\u0441\u0438\u0442\u044c, \u0447\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0441\u0443\u0445\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438 \u043a\u0430\u043a \u043e\u043d\u0430 \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0438\u043d\u043e\u0433\u0434\u0430 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0433\u0430\u0437\u044b \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0447\u0430\u0441\u0442\u0435\u0439. \u0412\u043e\u0437\u0434\u0443\u0448\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0448\u0438\u0440\u043e\u043a\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0430 \u043f\u0440\u043e\u0441\u0442\u0430, \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0430 \u0438 \u043d\u0435 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u044f\u0435\u0442 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443.<\/p>\n\n\n\n<p>\u041d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u0430 \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u0432 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0441\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u0430\u044f \u0438 \u0433\u0430\u0437\u043e\u0432\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0432 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0413\u0430\u0437\u043e\u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u0430\u044f \u0441\u0440\u0435\u0434\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043e\u0437\u0434\u0443\u0448\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SF\u2086 \u0433\u0430\u0437\u043e\u0432\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u0435\u0437 \u043b\u0435\u0433\u043a\u043e\u0432\u043e\u0441\u043f\u043b\u0430\u043c\u0435\u043d\u044f\u044e\u0449\u0438\u0445\u0441\u044f \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0435\u0439, \u043e\u0447\u0435\u043d\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0440\u0438\u0441\u043a \u0432 \u0441\u043b\u0443\u0447\u0430\u0435 \u0443\u0442\u0435\u0447\u043a\u0438 \u0433\u0430\u0437\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0425\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u0440\u0438 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430\u0445<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041b\u0443\u0447\u0448\u0435 \u0434\u043b\u044f \u043e\u0447\u0435\u043d\u044c \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0435\u0431\u0443\u0435\u0442 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0435\u0431\u0443\u0435\u0442 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043d\u0430 \u0443\u0442\u0435\u0447\u043a\u0443 \u0433\u0430\u0437\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u043e\u0436\u0435\u0442 \u0431\u044b\u0442\u044c \u0434\u043e\u0440\u043e\u0436\u0435 \u0438 \u0431\u043e\u043b\u044c\u0448\u0435 \u043f\u043e \u0440\u0430\u0437\u043c\u0435\u0440\u0443<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u044b\u0447\u043d\u043e \u043c\u0435\u043d\u0435\u0435 \u0434\u043e\u0440\u043e\u0433\u043e\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u0442 \u0440\u0438\u0441\u043a\u0430 \u0443\u0442\u0435\u0447\u0435\u043a, \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u0435\u043d<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0413\u0430\u0437 SF\u2086 \u043c\u043e\u0436\u0435\u0442 \u043d\u0430\u043d\u0435\u0441\u0442\u0438 \u0432\u0440\u0435\u0434 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u0443\u0442\u0435\u0447\u043a\u0430\u0445 \u043c\u0430\u0441\u043b\u0430 \u0438\u043b\u0438 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0433\u0430\u0437\u0430\u0445. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/\">\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u0434\u043b\u044f \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445<\/a> \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u041a\u0430\u043a \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u043f\u0440\u0438\u043d\u0446\u0438\u043f \u0440\u0430\u0431\u043e\u0442\u044b<\/h3>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u0432\u044b \u0445\u043e\u0442\u0438\u0442\u0435 \u043f\u043e\u043d\u044f\u0442\u044c, \u0447\u0442\u043e \u0442\u0430\u043a\u043e\u0435 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0441\u0443\u0445\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440<\/a>, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u043d\u044f\u0442\u044c, \u043a\u0430\u043a \u043e\u043d \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0438\u0437\u043d\u0443\u0442\u0440\u0438. \u0421\u0443\u0445\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u043f\u0440\u0438\u043d\u0446\u0438\u043f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0439 \u0438\u043d\u0434\u0443\u043a\u0446\u0438\u0438. \u041e\u043d \u0441\u043e\u0441\u0442\u043e\u0438\u0442 \u0438\u0437 \u0434\u0432\u0443\u0445 \u043d\u0430\u0431\u043e\u0440\u043e\u0432 \u043a\u0430\u0442\u0443\u0448\u0435\u043a, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u0445 \u043e\u0431\u043c\u043e\u0442\u043a\u0430\u043c\u0438, \u043e\u0431\u0435\u0440\u043d\u0443\u0442\u044b\u0445 \u0432\u043e\u043a\u0440\u0443\u0433 \u043b\u0430\u043c\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0436\u0435\u043b\u0435\u0437\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430. \u041a\u043e\u0433\u0434\u0430 \u0447\u0435\u0440\u0435\u0437 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u0443\u044e \u043e\u0431\u043c\u043e\u0442\u043a\u0443 \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u0435\u0442\u0441\u044f \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a (AC), \u0432 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435 \u0441\u043e\u0437\u0434\u0430\u0435\u0442\u0441\u044f \u0438\u0437\u043c\u0435\u043d\u044f\u044e\u0449\u0435\u0435\u0441\u044f \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u043e\u043b\u0435. \u042d\u0442\u043e \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u043e\u043b\u0435 \u043f\u0440\u043e\u0445\u043e\u0434\u0438\u0442 \u0447\u0435\u0440\u0435\u0437 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0443\u044e \u043e\u0431\u043c\u043e\u0442\u043a\u0443, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043d\u0430\u0445\u043e\u0434\u0438\u0442\u0441\u044f \u0440\u044f\u0434\u043e\u043c, \u043d\u043e \u043d\u0435 \u0441\u043e\u043f\u0440\u0438\u043a\u0430\u0441\u0430\u0435\u0442\u0441\u044f \u0441 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u043e\u0439. \u0414\u0432\u0438\u0436\u0435\u043d\u0438\u0435 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u043e\u043b\u044f \u0438\u043d\u0434\u0443\u0446\u0438\u0440\u0443\u0435\u0442 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u043e \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0435. \u041d\u0430 \u0432\u044b\u0445\u043e\u0434\u0435 \u0432\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043d\u043e\u0432\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043d\u043e \u0434\u0432\u0435 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0435\u043d\u043d\u044b\u043c\u0438. \u042d\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0438\u0437\u043c\u0435\u043d\u044f\u0442\u044c \u0443\u0440\u043e\u0432\u043d\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u043e \u043c\u0435\u0440\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u041e\u0431\u043c\u043e\u0442\u043a\u0438 \u043d\u0438\u043a\u043e\u0433\u0434\u0430 \u043d\u0435 \u0441\u043e\u043f\u0440\u0438\u043a\u0430\u0441\u0430\u044e\u0442\u0441\u044f \u0434\u0440\u0443\u0433 \u0441 \u0434\u0440\u0443\u0433\u043e\u043c. \u0412\u0441\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0435\u0442\u0441\u044f \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u043c \u043f\u043e\u043b\u0435\u043c, \u0447\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041c\u0435\u0442\u043e\u0434\u044b \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f<\/h3>\n\n\n\n<p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u043c\u0430\u0441\u043b\u043e \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f. \u0412\u043c\u0435\u0441\u0442\u043e \u044d\u0442\u043e\u0433\u043e \u043e\u043d\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0433\u0430\u0437\u044b \u0434\u043b\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u043d\u0438\u0437\u043a\u043e\u0439 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u043c\u043d\u043e\u0433\u0438\u0445 \u0441\u0440\u0435\u0434.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0412\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u044f \u0432\u043e\u0437\u0434\u0443\u0445\u0430<\/h4>\n\n\n\n<p>\u0412\u044b \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0442\u0435, \u0447\u0442\u043e \u0432 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0433\u043e \u043c\u0435\u0442\u043e\u0434\u0430 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432\u043e\u0437\u0434\u0443\u0445. \u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0438\u043c\u0435\u0435\u0442 \u043e\u0442\u043a\u0440\u044b\u0442\u044b\u0435 \u043f\u0430\u0437\u044b \u0438\u043b\u0438 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043e\u0442\u0432\u0435\u0440\u0441\u0442\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445\u0443 \u0446\u0438\u0440\u043a\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u043e\u043a\u0440\u0443\u0433 \u043e\u0431\u043c\u043e\u0442\u043e\u043a \u0438 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430. \u0412\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043d\u0430\u0433\u0440\u0435\u0432\u0430\u0435\u0442\u0441\u044f. \u0422\u0435\u043f\u043b\u044b\u0439 \u0432\u043e\u0437\u0434\u0443\u0445 \u043f\u043e\u0434\u043d\u0438\u043c\u0430\u0435\u0442\u0441\u044f \u0438 \u0432\u044b\u0445\u043e\u0434\u0438\u0442 \u0447\u0435\u0440\u0435\u0437 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043e\u0442\u0432\u0435\u0440\u0441\u0442\u0438\u044f, \u0430 \u043d\u0430 \u0435\u0433\u043e \u043c\u0435\u0441\u0442\u043e \u043f\u043e\u0441\u0442\u0443\u043f\u0430\u0435\u0442 \u0431\u043e\u043b\u0435\u0435 \u0445\u043e\u043b\u043e\u0434\u043d\u044b\u0439 \u0432\u043e\u0437\u0434\u0443\u0445. \u042d\u0442\u043e\u0442 \u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0439 \u043a\u043e\u043d\u0432\u0435\u043a\u0446\u0438\u0435\u0439. \u0412 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432 \u0434\u043b\u044f \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0442\u043e\u0440\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0431\u0434\u0443\u0432\u0430\u044e\u0442 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u0432\u043e\u0437\u0434\u0443\u0445\u043e\u043c. \u041c\u0430\u0441\u043b\u043e \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u0443\u0442\u0435\u0447\u043a\u0438 \u0438 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0443 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430.<\/p><\/li><li><p>\u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u0440\u0430\u0437\u043b\u0438\u0432\u0435 \u043c\u0430\u0441\u043b\u0430 \u0438\u043b\u0438 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438.<\/p><\/li><li><p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u0445\u043e\u043b\u043e\u0434\u043d\u044b\u043c \u0434\u0430\u0436\u0435 \u0432 \u0437\u0430\u043a\u0440\u044b\u0442\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0438\u043b\u0438 \u0437\u0434\u0430\u043d\u0438\u044f\u0445.<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >\u0413\u0430\u0437\u043e\u0432\u0430\u044f \u0438 \u0442\u0432\u0435\u0440\u0434\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/h4>\n\n\n\n<p>\u0412 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0433\u0430\u0437\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a SF\u2086, \u0438\u043b\u0438 \u0442\u0432\u0435\u0440\u0434\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0430\u044f \u0441\u043c\u043e\u043b\u0430. \u0413\u0430\u0437 \u0438\u043b\u0438 \u0441\u043c\u043e\u043b\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0442 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u0438 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044f \u043f\u043e\u043f\u0430\u0434\u0430\u043d\u0438\u0435 \u0432\u043b\u0430\u0433\u0438 \u0438 \u043f\u044b\u043b\u0438. \u042d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0430\u044f \u0441\u043c\u043e\u043b\u0430 \u0442\u0430\u043a\u0436\u0435 \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442 \u043a\u0430\u043a \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u043f\u043e\u0436\u0430\u0440\u043d\u044b\u0439 \u0431\u0430\u0440\u044c\u0435\u0440. \u0412 \u0441\u043b\u0443\u0447\u0430\u0435 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0441\u043c\u043e\u043b\u0430 \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0431\u044b\u0441\u0442\u0440\u043e \u043f\u043e\u0442\u0443\u0448\u0438\u0442\u044c \u043e\u0433\u043e\u043d\u044c \u0438 \u0432\u044b\u0434\u0435\u043b\u044f\u0435\u0442 \u043e\u0447\u0435\u043d\u044c \u043c\u0430\u043b\u043e \u0434\u044b\u043c\u0430. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438\u043c\u0435\u0435\u0442 \u043f\u0435\u0440\u0432\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u0442\u043e\u0434 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u0430\u043a \u044d\u0442\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u044f \u0432\u043e\u0437\u0434\u0443\u0445\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0435\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u0443\u044e \u0438\u043b\u0438 \u043f\u0440\u0438\u043d\u0443\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u044e \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0431\u043c\u043e\u0442\u043e\u043a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0441\u0442\u043e\u0439, \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0439, \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0439 \u043e\u0441\u043e\u0431\u043e\u0433\u043e \u0443\u0445\u043e\u0434\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0413\u0430\u0437\u043e\u0432\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0433\u0430\u0437\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a SF\u2086, \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438\/\u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0432\u0435\u0440\u0434\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0443\u044e \u0441\u043c\u043e\u043b\u0443 \u0434\u043b\u044f \u043f\u043e\u043a\u0440\u044b\u0442\u0438\u044f \u043e\u0431\u043c\u043e\u0442\u043e\u043a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0433\u043d\u0435\u0441\u0442\u043e\u0439\u043a\u0438\u0439, \u0432\u043b\u0430\u0433\u043e\u0441\u0442\u043e\u0439\u043a\u0438\u0439<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043c\u0430\u0441\u043b\u0430 \u0432 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c \u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u0442\u0430\u043a\u0438\u0445 \u043c\u0435\u0441\u0442, \u043a\u0430\u043a \u0448\u043a\u043e\u043b\u044b, \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u044b \u0438 \u043e\u0444\u0438\u0441\u044b.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041f\u0440\u043e\u0446\u0435\u0441\u0441 \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/h3>\n\n\n\n<p>\u0414\u043b\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0433\u043e \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0443\u0440\u043e\u0432\u043d\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u041f\u0440\u0438 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u043a \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0443 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u043e\u043b\u0435 \u0432 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435. \u042d\u0442\u043e \u043f\u043e\u043b\u0435 \u0441\u0432\u044f\u0437\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u0441\u043e \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u043e\u0439 \u0438 \u0438\u043d\u0434\u0443\u0446\u0438\u0440\u0443\u0435\u0442 \u043d\u043e\u0432\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435. \u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0432\u0438\u0442\u043a\u043e\u0432 \u0432 \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442, \u0431\u0443\u0434\u0435\u0442 \u043b\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u043e\u0432\u044b\u0448\u0430\u0442\u044c\u0441\u044f \u0438\u043b\u0438 \u043f\u043e\u043d\u0438\u0436\u0430\u0442\u044c\u0441\u044f. \u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0435\u0441\u043b\u0438 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0430\u044f \u043e\u0431\u043c\u043e\u0442\u043a\u0430 \u0438\u043c\u0435\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0435 \u0432\u0438\u0442\u043a\u043e\u0432, \u0447\u0435\u043c \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u0430\u044f, \u043d\u0430 \u0432\u044b\u0445\u043e\u0434\u0435 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435. \u0415\u0441\u043b\u0438 \u0432\u0438\u0442\u043a\u043e\u0432 \u0431\u043e\u043b\u044c\u0448\u0435, \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0431\u0443\u0434\u0435\u0442 \u0432\u044b\u0448\u0435.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u043e\u0432\u044b\u0448\u0430\u0442\u044c \u0438\u043b\u0438 \u043f\u043e\u043d\u0438\u0436\u0430\u0442\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p><\/li><li><p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u0438 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439, \u0447\u0442\u043e \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u0435\u0442 \u0432\u0430\u0448\u0443 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c.<\/p><\/li><li><p>\u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430 \u0438 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043c\u043e\u043b\u0443 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0412\u044b\u043d\u043e\u0441\u043d\u0430\u044f \u043d\u0430\u0434\u043f\u0438\u0441\u044c:<\/strong> \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u043c\u0435\u044e\u0442 \u043f\u0435\u0440\u0432\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0441\u043f\u043e\u043a\u043e\u0439\u0441\u0442\u0432\u0438\u0435 \u0438 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0431\u0435\u0437 \u0433\u0440\u044f\u0437\u0438 \u0438 \u043c\u0430\u0441\u043b\u0430.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u043e\u0435 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435<\/h3>\n\n\n\n<p>\u0412\u044b \u043d\u0430\u0439\u0434\u0435\u0442\u0435 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0441\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u0432\u043e \u043c\u043d\u043e\u0433\u0438\u0445 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u0430\u0445. \u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435 \u0442\u0430\u043c, \u0433\u0434\u0435 \u044d\u0442\u043e \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u0443\u0432\u0438\u0434\u0435\u0442\u044c \u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f\u0445, \u0432 \u0442\u043e\u0440\u0433\u043e\u0432\u044b\u0445 \u0446\u0435\u043d\u0442\u0440\u0430\u0445, \u043e\u0444\u0438\u0441\u043d\u044b\u0445 \u0437\u0434\u0430\u043d\u0438\u044f\u0445 \u0438 \u0434\u0430\u0436\u0435 \u0432 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0436\u0435\u043b\u0435\u0437\u043d\u044b\u0435 \u0434\u043e\u0440\u043e\u0433\u0438 \u0438 \u0441\u0442\u0430\u043d\u0446\u0438\u0438 \u043c\u0435\u0442\u0440\u043e. \u0418\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0438 \u043f\u0440\u043e\u0441\u0442\u044b\u043c\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438.<\/p>\n\n\n\n<p>\u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0438\u0437 \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0422\u0438\u043f \u0437\u0430\u044f\u0432\u043a\u0438<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043f\u043e\u0434\u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0430\u0434\u0435\u0436\u043d\u043e\u0435 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u043e\u0432.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u044c\u043d\u0438\u0446\u044b \u0438 \u0446\u0435\u043d\u0442\u0440\u044b \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u0445<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u043e\u0440\u0433\u043e\u0432\u044b\u0435 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u044f \u0434\u043b\u044f \u0442\u043e\u0440\u0433\u043e\u0432\u044b\u0445 \u0438 \u043e\u0444\u0438\u0441\u043d\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0416\u0435\u043b\u0435\u0437\u043d\u044b\u0435 \u0434\u043e\u0440\u043e\u0433\u0438 \u0438 \u043c\u0435\u0442\u0440\u043e\u043f\u043e\u043b\u0438\u0442\u0435\u043d<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u0443\u044e \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0443.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/\">\u041f\u0440\u043e\u0435\u043a\u0442\u044b \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0418\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u0441 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c\u0438 \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u043e\u0439 \u0438 \u0432\u0435\u0442\u0440\u043e\u0432\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0432 \u0442\u0430\u043a\u0438\u0445 \u043c\u0435\u0441\u0442\u0430\u0445, \u043a\u0430\u043a \u0430\u044d\u0440\u043e\u043f\u043e\u0440\u0442\u044b, \u0441\u0442\u0430\u043d\u0446\u0438\u0438 \u043c\u0435\u0442\u0440\u043e \u0438 \u0432\u044b\u0441\u043e\u0442\u043d\u044b\u0435 \u0437\u0434\u0430\u043d\u0438\u044f, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u043d\u0435 \u043f\u0440\u043e\u0442\u0435\u043a\u0430\u044e\u0442 \u0438 \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0411\u043e\u043b\u044c\u043d\u0438\u0446\u044b \u0438 \u0448\u043a\u043e\u043b\u044b<\/h3>\n\n\n\n<p>\u0412 \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u0430\u0445 \u0438 \u0448\u043a\u043e\u043b\u0430\u0445 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u0430 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0430\u044f \u0438 \u0431\u0435\u0441\u0448\u0443\u043c\u043d\u0430\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u044f. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0438 \u0442\u043e, \u0438 \u0434\u0440\u0443\u0433\u043e\u0435. \u041e\u043d\u0438 \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u043c\u0430\u0441\u043b\u043e, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0443\u0442\u0435\u0447\u0435\u043a. \u0418\u0445 \u0431\u0435\u0441\u0448\u0443\u043c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0432\u044b \u043d\u0435 \u0431\u0443\u0434\u0435\u0442\u0435 \u043c\u0435\u0448\u0430\u0442\u044c \u043f\u0430\u0446\u0438\u0435\u043d\u0442\u0430\u043c \u0438\u043b\u0438 \u0443\u0447\u0430\u0449\u0438\u043c\u0441\u044f. \u0412\u044b \u0442\u0430\u043a\u0436\u0435 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043b\u0443\u0436\u0438\u0442 \u0434\u043e\u043b\u0433\u043e \u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439.<\/p>\n\n\n\n<p>\u0412\u043e\u0442 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043f\u0440\u0438\u0447\u0438\u043d, \u043f\u043e \u043a\u043e\u0442\u043e\u0440\u044b\u043c \u0432\u0430\u043c \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0432\u044b\u0431\u0438\u0440\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0434\u043b\u044f \u0431\u043e\u043b\u044c\u043d\u0438\u0446 \u0438 \u0448\u043a\u043e\u043b:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0438\u0447\u0438\u043d\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u0435\u0437\u043c\u0430\u0441\u043b\u044f\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438 \u0443\u0433\u0440\u043e\u0437\u0443 \u0434\u043b\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0430 \u043c\u0430\u0441\u043b\u0430.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430 \u0438 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0436\u0430\u0440\u043e\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u043f\u0440\u0430\u0432\u0438\u043b\u0430\u043c \u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0447\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438 \u0445\u043e\u0440\u043e\u0448\u0435\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u044e\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0438 \u043b\u0435\u0433\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0442\u0435\u0441\u043d\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0431\u0435\u0441\u0448\u0443\u043c\u043d\u043e, \u0447\u0442\u043e \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439, \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a \u0448\u0443\u043c\u0443.<\/p><\/li><li><p>\u041f\u043e \u0438\u0441\u0442\u0435\u0447\u0435\u043d\u0438\u0438 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0438\u0445 \u043c\u043e\u0436\u043d\u043e \u043b\u0435\u0433\u043a\u043e \u0443\u0442\u0438\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u043d\u0435 \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u0442 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/h3>\n\n\n\n<p>\u0412\u044b \u0438\u0433\u0440\u0430\u0435\u0442\u0435 \u043a\u043b\u044e\u0447\u0435\u0432\u0443\u044e \u0440\u043e\u043b\u044c \u0432 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0435 \u0447\u0438\u0441\u0442\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438, \u043a\u043e\u0433\u0434\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0435 \u0441\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0432 \u043f\u0440\u043e\u0435\u043a\u0442\u0430\u0445 \u043f\u043e \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u043c \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430\u043c \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0435 \u0442\u0443\u0440\u0431\u0438\u043d\u044b \u0438 \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0435 \u043f\u0430\u043d\u0435\u043b\u0438 \u043a \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0438. \u041e\u043d\u0438 \u043e\u0431\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u0431\u043e\u043b\u044c\u0448\u0438\u0435 \u043e\u0431\u044a\u0435\u043c\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435 \u0438\u043b\u0438 \u0432 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u044b\u0445 \u043c\u0435\u0441\u0442\u0430\u0445.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0414\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0432 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u043a\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u043d\u0438 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0435 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0435 \u0442\u0443\u0440\u0431\u0438\u043d\u044b \u0438 \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0435 \u043f\u0430\u043d\u0435\u043b\u0438, \u043a \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u0435, \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u043e\u0431\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u0435 \u043e\u0431\u044a\u0435\u043c\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u0439 \u0434\u0438\u0437\u0430\u0439\u043d \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0434\u043e\u0441\u0442\u0438\u0447\u044c \u0446\u0435\u043b\u0435\u0439 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0432\u0438\u0442\u0438\u044f.<\/p><\/li><li><p>\u0412\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u043c\u0435\u043d\u044c\u0448\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435.<\/p><\/li><li><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0445 \u0438 \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u0439.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0415\u0441\u043b\u0438 \u0432\u044b \u0445\u043e\u0442\u0438\u0442\u0435 \u0443\u0437\u043d\u0430\u0442\u044c, \u0434\u043b\u044f \u0447\u0435\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0441\u0443\u0445\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440, \u0432\u044b \u0443\u0432\u0438\u0434\u0438\u0442\u0435, \u0447\u0442\u043e \u043e\u043d \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445, \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c<\/h3>\n\n\n\n<p>\u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438, \u043a\u043e\u0433\u0434\u0430 \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u0442\u0435 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0441\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a>. \u0412 \u044d\u0442\u0438\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043c\u0430\u0441\u043b\u043e, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438 \u0443\u0442\u0435\u0447\u043a\u0438 \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u044b\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432. \u041f\u0440\u043e\u0447\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f, \u0447\u0430\u0441\u0442\u043e \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u043d\u0430\u044f \u0438\u0437 \u043b\u0438\u0442\u043e\u0439 \u0441\u043c\u043e\u043b\u044b, \u0441\u043b\u0443\u0436\u0438\u0442 \u0431\u0430\u0440\u044c\u0435\u0440\u043e\u043c \u043e\u0442 \u0432\u043b\u0430\u0433\u0438 \u0438 \u043f\u044b\u043b\u0438. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u044d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u043f\u043e\u0436\u0430\u0440\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438\u043c\u0435\u0435\u0442 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u044b, \u0448\u043a\u043e\u043b\u044b \u0438 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438\u0435 \u0437\u0434\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b, \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0449\u0438\u0435 \u0438\u0445 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c. \u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>E3<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u0440\u0430\u0431\u043e\u0447\u0438\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441 \u043b\u0438\u0442\u043e\u0439 \u0441\u043c\u043e\u043b\u043e\u0439.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>C3<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f, \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0449\u0430\u044f \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>F1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u0442\u0430\u043a\u0436\u0435 \u043c\u043e\u0436\u0435\u0442\u0435 \u0443\u0431\u0435\u0434\u0438\u0442\u044c\u0441\u044f \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c, \u0442\u0430\u043a\u0438\u043c \u043a\u0430\u043a IEC 60076 \u0438 IS 2026. \u042d\u0442\u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u043e\u0437\u043d\u0430\u0447\u0430\u044e\u0442, \u0447\u0442\u043e \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0443, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0431\u0443\u0434\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0432 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0438\u043b\u0438 \u0432 \u043e\u0431\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0445 \u043c\u0435\u0441\u0442\u0430\u0445, \u043d\u0435 \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u044f\u0441\u044c \u043e \u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0439 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438\u043b\u0438 \u0443\u0442\u0435\u0447\u043a\u0430\u0445 \u043c\u0430\u0441\u043b\u0430.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041d\u0438\u0437\u043a\u0438\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/h3>\n\n\n\n<p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u0438 \u0434\u0435\u043d\u044c\u0433\u0438, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u0412 \u0438\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u0430\u044f \u0438\u043b\u0438 \u0442\u0432\u0435\u0440\u0434\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430 \u0438\u043b\u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0439. \u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0431\u0435\u0437 \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0438 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u043c\u0430\u0441\u043b\u0430 \u0438 \u0443\u0442\u0435\u0447\u0435\u043a. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0441\u043e\u0441\u0440\u0435\u0434\u043e\u0442\u043e\u0447\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0445 \u0437\u0430\u0434\u0430\u0447\u0430\u0445, \u0430 \u043d\u0435 \u043d\u0430 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430\u0445.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0437\u0430\u043c\u0435\u043d\u044f\u0442\u044c \u0438\u043b\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043c\u0430\u0441\u043b\u043e.<\/p><\/li><li><p>\u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0443\u0431\u043e\u0440\u043a\u0438 \u0440\u0430\u0437\u043b\u0438\u0432\u043e\u0432 \u0438\u043b\u0438 \u043e\u0431\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0441 \u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u043e\u0442\u0445\u043e\u0434\u0430\u043c\u0438.<\/p><\/li><li><p>\u0412\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u043c\u0435\u043d\u044c\u0448\u0435 \u043d\u0430 \u043f\u043b\u0430\u043d\u043e\u0432\u044b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0434\u0430\u0436\u0435 \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u0447\u0442\u043e \u043e\u043d\u0438 \u0431\u0443\u0434\u0443\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0441 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435\u043c.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u044f \u0438 \u0440\u0430\u0441\u0445\u043e\u0434\u044b \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435, \u0432\u044b\u0431\u0440\u0430\u0432 \u0434\u043b\u044f \u0441\u0432\u043e\u0435\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430<\/h3>\n\n\n\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430, \u0432\u044b \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u0437\u0430\u0449\u0438\u0442\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b. \u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043d\u0435 \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u0442 \u043c\u0430\u0441\u043b\u0430, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a\u0430 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u043f\u043e\u0447\u0432\u044b \u0438 \u0432\u043e\u0434\u044b. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u043b\u0438\u0442\u0430\u044f \u0441\u043c\u043e\u043b\u0430 \u0438 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0430\u044f \u0441\u043c\u043e\u043b\u0430, \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u043c\u0438 \u0438 \u043f\u0440\u0438\u0433\u043e\u0434\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u043a\u0438. \u0412\u044b \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0435 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0435 \u0440\u0430\u0437\u0432\u0438\u0442\u0438\u0435, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043c\u0430\u0441\u043b\u0430 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0440\u0438\u0441\u043a\u0430 \u0443\u0442\u0435\u0447\u0435\u043a \u0438\u043b\u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f.<\/p><\/li><li><p>\u041f\u043e \u0438\u0441\u0442\u0435\u0447\u0435\u043d\u0438\u0438 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u0435\u0433\u043e \u0447\u0430\u0441\u0442\u0435\u0439 \u043c\u043e\u0436\u043d\u043e \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c.<\/p><\/li><li><p>\u0414\u0438\u0437\u0430\u0439\u043d \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0433\u043e \u0441\u0442\u0440\u043e\u0438\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u0438 \u0446\u0435\u043b\u044f\u043c \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0432\u0438\u0442\u0438\u044f.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0442\u0430\u043a\u0436\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u044f\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f. \u0412\u044b \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442\u0435 \u0441\u0432\u043e\u0439 \u0443\u0433\u043b\u0435\u0440\u043e\u0434\u043d\u044b\u0439 \u0441\u043b\u0435\u0434 \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0435 \u0438\u043d\u0438\u0446\u0438\u0430\u0442\u0438\u0432\u044b \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0447\u0438\u0441\u0442\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0412\u044b\u043d\u043e\u0441\u043d\u0430\u044f \u043d\u0430\u0434\u043f\u0438\u0441\u044c:<\/strong> \u0412\u044b \u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442\u0435 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0432\u043b\u0438\u044f\u043d\u0438\u0435 \u043d\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443 \u0438 \u0437\u0434\u043e\u0440\u043e\u0432\u044c\u0435 \u043d\u0430\u0441\u0435\u043b\u0435\u043d\u0438\u044f, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0434\u043b\u044f \u0441\u0432\u043e\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c<\/h3>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0440\u0430\u0431\u043e\u0442\u0430\u043b\u0438 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u043e \u043a\u0430\u0436\u0434\u044b\u0439 \u0434\u0435\u043d\u044c. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0434\u0430\u0436\u0435 \u0432 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u043d\u0430 \u0442\u043e, \u0447\u0442\u043e \u043e\u043d\u0438 \u0431\u0443\u0434\u0443\u0442 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0442\u044c \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438 \u0437\u0430\u0449\u0438\u0449\u0430\u0442\u044c \u0432\u0430\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043e\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439. \u0412 \u0438\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043f\u0440\u043e\u0447\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f, \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u0430\u044f \u043a \u0432\u043b\u0430\u0433\u0435, \u043f\u044b\u043b\u0438 \u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f\u043c. \u0412\u0430\u043c \u043d\u0435 \u043f\u0440\u0438\u0434\u0435\u0442\u0441\u044f \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u0432\u043d\u0435\u0437\u0430\u043f\u043d\u044b\u0445 \u043f\u043e\u043b\u043e\u043c\u043a\u0430\u0445 \u0438\u043b\u0438 \u0447\u0430\u0441\u0442\u044b\u0445 \u0440\u0435\u043c\u043e\u043d\u0442\u0430\u0445.<\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0438\u0437\u0433\u043e\u0442\u0430\u0432\u043b\u0438\u0432\u0430\u044e\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0438\u0437 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432. \u041b\u0438\u0442\u0430\u044f \u0441\u043c\u043e\u043b\u0430 \u0438 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u043e\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439. \u0412\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u043f\u0435\u0440\u0435\u043f\u0430\u0434\u044b \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438. \u0422\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0432\u0438\u0436\u0443\u0449\u0438\u0445\u0441\u044f \u0447\u0430\u0441\u0442\u0435\u0439, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0440\u0438\u0441\u043a \u0438\u0437\u043d\u043e\u0441\u0430 \u0438 \u043f\u043e\u043b\u043e\u043c\u043a\u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442\u0441\u044f. \u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0432 \u043c\u0435\u0441\u0442\u0430\u0445 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u044c\u044e \u0438\u043b\u0438 \u0437\u0430\u043f\u044b\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c\u044e, \u0438 \u043e\u043d\u0438 \u0431\u0443\u0434\u0443\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0431\u0435\u0437 \u043f\u0440\u043e\u0431\u043b\u0435\u043c.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u043f\u0440\u043e\u0441\u0442\u043e\u0438 \u043d\u0435\u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u044b, \u0446\u0435\u043d\u0442\u0440\u044b \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u0445 \u0438 \u0437\u0430\u0432\u043e\u0434\u044b.<\/p><\/blockquote>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0437\u0430\u0434\u0430\u0442\u044c\u0441\u044f \u0432\u043e\u043f\u0440\u043e\u0441\u043e\u043c, \u043a\u0430\u043a \u0434\u043e\u043b\u0433\u043e \u0441\u043b\u0443\u0436\u0438\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u041f\u0440\u0438 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u043c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043e\u043d \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0442\u044c \u0434\u043e\u043b\u0433\u043e. \u0412\u043e\u0442 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0444\u0430\u043a\u0442\u043e\u0432 \u043e \u0441\u0440\u043e\u043a\u0435 \u0435\u0433\u043e \u0441\u043b\u0443\u0436\u0431\u044b:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0433\u043e \u0441\u0438\u043b\u043e\u0432\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u043e\u0442 30 \u0434\u043e 50 \u043b\u0435\u0442.<\/p><\/li><li><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u043c\u043e\u0434\u0435\u043b\u0438 Fuji Electric \u0438\u0437 \u043b\u0438\u0442\u043e\u0439 \u0441\u043c\u043e\u043b\u044b, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e, \u0438\u043c\u0435\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0441\u043f\u043e\u043a\u043e\u0439\u043d\u044b, \u0437\u043d\u0430\u044f, \u0447\u0442\u043e \u0432\u0430\u0448 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0442 \u0432\u0430\u043c \u0434\u0435\u0441\u044f\u0442\u0438\u043b\u0435\u0442\u0438\u044f\u043c\u0438. \u0412\u0430\u043c \u043d\u0435 \u043f\u0440\u0438\u0434\u0435\u0442\u0441\u044f \u0447\u0430\u0441\u0442\u043e \u0435\u0433\u043e \u0437\u0430\u043c\u0435\u043d\u044f\u0442\u044c, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442 \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u0434\u0435\u043d\u044c\u0433\u0438 \u0438 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0442\u0445\u043e\u0434\u043e\u0432.<\/p>\n\n\n\n<p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0442\u0430\u043a\u0436\u0435 \u0445\u043e\u0440\u043e\u0448\u043e \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430\u043c\u0438 \u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u043c\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\u043c\u0438. \u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043e\u0431\u043c\u043e\u0442\u043a\u0438, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0438\u0445 \u043f\u043e\u043b\u043e\u043c\u043e\u043a. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0434\u043e\u0432\u0435\u0440\u0438\u0442\u044c\u0441\u044f \u044d\u0442\u0438\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0430\u0442 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0431\u044b\u0441\u0442\u0440\u043e\u043c \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0438 \u0443\u0441\u043b\u043e\u0432\u0438\u0439. \u0418\u0445 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0434\u0435\u043b\u0430\u0435\u0442 \u0438\u0445 \u0440\u0430\u0437\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439.<\/p>\n\n\n\n<p>\u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u043d\u043e, \u043f\u043e\u0447\u0435\u043c\u0443 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0442\u0430\u043a\u0438\u043c\u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u043c\u0438:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0434\u043b\u044f \u0432\u0430\u0441<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0432\u0435\u0440\u0434\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432 \u043a \u0432\u043b\u0430\u0433\u0435 \u0438 \u043f\u044b\u043b\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043d\u0438\u0436\u0430\u0435\u0442 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0437\u0430\u043c\u0435\u043d\u0443<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0443 \u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439 \u0440\u0438\u0441\u043a \u043d\u0435\u0443\u0434\u0430\u0447\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0431\u0443\u0434\u0435\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0442\u043e\u0433\u0434\u0430, \u043a\u043e\u0433\u0434\u0430 \u043e\u043d\u043e \u0432\u0430\u043c \u0431\u043e\u043b\u044c\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043d\u0443\u0436\u043d\u043e. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u044b\u0435 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u0433\u043e\u0434 \u0437\u0430 \u0433\u043e\u0434\u043e\u043c. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0432 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u043c \u0432 \u0438\u0445 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438. \u0418\u0445 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043d\u0435\u043f\u0440\u0435\u0434\u0432\u0438\u0434\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0441\u0442\u043e\u0435\u0432 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0439 \u0440\u0430\u0431\u043e\u0442\u044b.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0412\u044b\u043d\u043e\u0441\u043d\u0430\u044f \u043d\u0430\u0434\u043f\u0438\u0441\u044c:<\/strong> \u0412\u044b\u0431\u0438\u0440\u0430\u0439\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430, \u0435\u0441\u043b\u0438 \u0432\u044b \u0446\u0435\u043d\u0438\u0442\u0435 \u0434\u043e\u043b\u0433\u043e\u0441\u0440\u043e\u0447\u043d\u0443\u044e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0438 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0432\u0430\u0448\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u043c \u043d\u0430\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u0435\u043c<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f<\/h3>\n\n\n\n<p>\u0412\u0430\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0437\u043d\u0430\u0442\u044c, \u0447\u0435\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043e\u0442\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f \u043e\u0442 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/oil-immersed-transformer\/\">\u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u0441\u0434\u0435\u043b\u0430\u0442\u044c \u0432\u044b\u0431\u043e\u0440. \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f \u0437\u0430\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u0432 \u043c\u0435\u0442\u043e\u0434\u0430\u0445 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f, \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u0445 \u043a \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435 \u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u0445 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u043f\u0440\u0438\u043d\u0443\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u044e. \u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0446\u0438\u0440\u043a\u0443\u043b\u044f\u0446\u0438\u044e \u043c\u0430\u0441\u043b\u0430. \u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0447\u0430\u0441\u0442\u043e \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u044e\u0442 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435, \u0430 \u0441\u0443\u0445\u0438\u0435 \u043c\u043e\u0434\u0435\u043b\u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0438\u043b\u0438 \u043f\u043e\u0436\u0430\u0440\u043e\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0437\u043e\u043d\u0430\u0445.<\/p>\n\n\n\n<p>\u041d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u0430 \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u0432 \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u043e\u0431\u043e\u0431\u0449\u0435\u043d\u044b \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438 \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041c\u0430\u0441\u043b\u043e\u043d\u0430\u043f\u043e\u043b\u043d\u0435\u043d\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u0443\u0445\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0426\u0438\u0440\u043a\u0443\u043b\u044f\u0446\u0438\u044f \u043c\u0430\u0441\u043b\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043e\u0437\u0434\u0443\u0445\/\u0415\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0439 \u0438\u043b\u0438 \u043f\u0440\u0438\u043d\u0443\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0438 (\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0435 \u0437\u043e\u043d\u044b)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0441\u043e\u043a\u0438\u0439 (\u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043c\u0430\u0441\u043b\u0430, \u0443\u0442\u0435\u0447\u043a\u0438)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0437\u043a\u0438\u0439 (\u0431\u0435\u0437 \u043c\u0430\u0441\u043b\u0430)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0436\u0430\u0440\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043e\u0441\u043f\u043b\u0430\u043c\u0435\u043d\u044f\u044e\u0449\u0438\u0439\u0441\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u0432\u043e\u0441\u043f\u043b\u0430\u043c\u0435\u043d\u044f\u044e\u0449\u0438\u0439\u0441\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0448\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043c\u043d\u043e\u0433\u043e \u043d\u0438\u0436\u0435<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043e 1000+ \u041c\u0412\u0410<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0414\u043e ~30 \u041c\u0412\u0410<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u043d\u044c\u0448\u0438\u0435 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0438\u0441\u043a \u0443\u0442\u0435\u0447\u043a\u0438 \u043d\u0435\u0444\u0442\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0439<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043c\u0435\u0436\u0434\u0443 \u044d\u0442\u0438\u043c\u0438 \u0434\u0432\u0443\u043c\u044f \u0442\u0438\u043f\u0430\u043c\u0438 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041f\u043b\u044e\u0441\u044b \u0438 \u043c\u0438\u043d\u0443\u0441\u044b<\/h3>\n\n\n\n<p>\u041e\u0431\u0430 \u0442\u0438\u043f\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0438\u043c\u0435\u044e\u0442 \u0441\u0432\u043e\u0438 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043a\u0438. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u043f\u043e\u0436\u0430\u0440\u043d\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0433\u043e \u043e\u0431\u044a\u0435\u043c\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. \u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0442\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c\u044e \u0438 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0441\u0440\u043e\u043a\u043e\u043c \u0441\u043b\u0443\u0436\u0431\u044b. \u0412 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0439 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043a\u0438:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0410\u0441\u043f\u0435\u043a\u0442<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041b\u0435\u0433\u043a\u0438\u0439, \u043e\u0433\u043d\u0435\u0441\u0442\u043e\u0439\u043a\u0438\u0439<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0443\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u0441\u043b\u043e\u0436\u043d\u044b\u0435; \u0447\u0430\u0441\u0442\u043e \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u044e\u0442\u0441\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0449\u0435; \u0432\u043e\u0437\u043c\u043e\u0436\u0435\u043d \u0430\u043d\u0430\u043b\u0438\u0437 \u043c\u0430\u0441\u043b\u0430<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0436\u0438\u0437\u043d\u0438<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0442 15 \u0434\u043e 25 \u043b\u0435\u0442<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u043e\u0442 25 \u0434\u043e 35 \u043b\u0435\u0442<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u043e\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041b\u0443\u0447\u0448\u0435 \u0434\u043b\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0422\u0440\u0435\u0431\u0443\u0435\u0442 \u043e\u0441\u0442\u043e\u0440\u043e\u0436\u043d\u043e\u0433\u043e \u043e\u0431\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0441 \u043c\u0430\u0441\u043b\u043e\u043c<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u0437\u0432\u0443\u043a\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b\u0448\u0435 (64\u201370 \u0434\u0411)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0438\u0436\u043d\u044f\u044f (58\u201363 \u0434\u0411)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0420\u0430\u0437\u043c\u0435\u0440 \u0438 \u0432\u0435\u0441<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0411\u043e\u043b\u0435\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u0439 \u0438\u0437-\u0437\u0430 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0433\u043e \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041c\u0435\u043d\u044c\u0448\u0438\u0439 \u0440\u0430\u0437\u043c\u0435\u0440 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u043c\u0430\u0441\u043b\u044f\u043d\u043e\u043c\u0443 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044e<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u043c\u0435\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b, \u043e\u0431\u044b\u0447\u043d\u043e \u043e\u0442 15 \u0434\u043e 25 \u043b\u0435\u0442.<\/p><\/li><li><p>\u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u043e\u043b\u044c\u0448\u0435, \u0447\u0430\u0441\u0442\u043e \u043e\u0442 25 \u0434\u043e 35 \u043b\u0435\u0442.<\/p><\/li><li><p>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u0447\u0442\u043e \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0443 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0431\u043e\u043b\u044c\u0448\u0435 \u0438 \u0448\u0443\u043c\u043d\u0435\u0435, \u043d\u043e \u0437\u0430\u0442\u043e \u0432\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430 \u0438 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0412\u044b\u0431\u043e\u0440 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u0442\u0438\u043f\u0430<\/h3>\n\n\n\n<p>\u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u0442\u044c \u0442\u0438\u043f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0432\u0430\u0448\u0438\u043c\u0438 \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u043c\u0438 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044f\u043c\u0438. \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u043c\u0435\u0441\u0442, \u0433\u0434\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438\u043c\u0435\u0435\u0442 \u043f\u0435\u0440\u0432\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u0443\u0432\u0438\u0434\u0435\u0442\u044c \u0432 \u0442\u043e\u0440\u0433\u043e\u0432\u044b\u0445 \u0446\u0435\u043d\u0442\u0440\u0430\u0445, \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u0430\u0445, \u043e\u0444\u0438\u0441\u0430\u0445 \u0438 \u0436\u0438\u043b\u044b\u0445 \u0437\u0434\u0430\u043d\u0438\u044f\u0445. \u0418\u0445 \u043f\u043e\u0436\u0430\u0440\u043e\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0438 \u043d\u0438\u0437\u043a\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0440\u0430\u0441\u0445\u043e\u0434\u044b \u0434\u0435\u043b\u0430\u044e\u0442 \u0438\u0445 \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445.<\/p>\n\n\n\n<p>\u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430, \u043a\u043e\u0433\u0434\u0430:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u0430\u043c \u043d\u0443\u0436\u043d\u043e \u043f\u043e\u0436\u0430\u0440\u043e\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0440\u0435\u0434.<\/p><\/li><li><p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043b\u043e \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u0431\u044b\u043b\u043e \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c.<\/p><\/li><li><p>\u0412\u044b \u043f\u043b\u0430\u043d\u0438\u0440\u0443\u0435\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435. \u0418\u0445 \u043c\u043e\u0436\u043d\u043e \u043d\u0430\u0439\u0442\u0438 \u043d\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445, \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u0438 \u043a\u0440\u0443\u043f\u043d\u044b\u0445 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u0430\u0445. \u041e\u043d\u0438 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c.<\/p>\n\n\n\n<p>\u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u0442\u044c \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b, \u043a\u043e\u0433\u0434\u0430:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u0430\u043c \u043d\u0443\u0436\u043d\u0430 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c (\u0441\u0432\u044b\u0448\u0435 30 \u041c\u0412\u0410).<\/p><\/li><li><p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b.<\/p><\/li><li><p>\u0412\u044b \u043f\u043b\u0430\u043d\u0438\u0440\u0443\u0435\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0412\u044b\u043d\u043e\u0441\u043d\u0430\u044f \u043d\u0430\u0434\u043f\u0438\u0441\u044c:<\/strong> \u041f\u0435\u0440\u0435\u0434 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435\u043c \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0432\u0441\u0435\u0433\u0434\u0430 \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0439\u0442\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438, \u0440\u0435\u0441\u0443\u0440\u0441\u044b \u0434\u043b\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438. \u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u043d\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0435 \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041f\u043e\u0436\u0430\u0440\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c<\/h3>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043e\u0441\u0442\u0430\u0432\u0430\u043b\u0438\u0441\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f. <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432 \u0438\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0435 \u043a \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044e \u043f\u043b\u0430\u043c\u0435\u043d\u0438 \u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u044e\u0449\u0438\u0435 \u0432\u044b\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0434\u044b\u043c\u0430. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0442\u0435\u0441\u0442\u0438\u0440\u0443\u044e\u0442 \u044d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043d\u0430 \u043f\u043e\u0436\u0430\u0440\u043e\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c, \u0432 \u0442\u043e\u043c \u0447\u0438\u0441\u043b\u0435 \u043d\u0430 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u044b\u043c\u0430 \u0438 \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u044b\u0445 \u0433\u0430\u0437\u043e\u0432, \u0432\u044b\u0434\u0435\u043b\u044f\u0435\u043c\u044b\u0445 \u043f\u0440\u0438 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u0438. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u0447\u0442\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u041a\u043b\u0430\u0441\u0441\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u043f\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u044f \u043e\u0433\u043d\u044f \u0444\u043e\u043a\u0443\u0441\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u043d\u0430 \u0432\u043e\u0441\u043f\u043b\u0430\u043c\u0435\u043d\u044f\u0435\u043c\u043e\u0441\u0442\u0438, \u043d\u0435\u043f\u0440\u043e\u0437\u0440\u0430\u0447\u043d\u043e\u0441\u0442\u0438 \u0434\u044b\u043c\u0430 \u0438 \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u043e\u0441\u0442\u0438.<\/p><\/li><li><p>\u0423\u0441\u043b\u043e\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u043a\u043b\u0430\u0441\u0441 F0 (\u0431\u0435\u0437 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f) \u0438 \u043a\u043b\u0430\u0441\u0441 F1 (\u0440\u0438\u0441\u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f).<\/p><\/li><li><p>\u041c\u0435\u0442\u043e\u0434\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u044e\u0442 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b, \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c \u0434\u044b\u043c\u0430 \u0438 \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u043e\u0441\u0442\u044c \u0433\u0430\u0437\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0437\u0440\u0443\u0448\u0430\u044e\u0449\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439.<\/p><\/li><li><p>\u0411\u0443\u043c\u0430\u0433\u0430 Nomex, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u0430\u044f \u0432 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445, \u043f\u043e\u0432\u044b\u0448\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0441\u0432\u043e\u0438\u043c \u043e\u0433\u043d\u0435\u0441\u0442\u043e\u0439\u043a\u0438\u043c \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430\u043c \u0438 \u043b\u0443\u0447\u0448\u0435\u0439 \u0432\u0438\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0432 \u0447\u0440\u0435\u0437\u0432\u044b\u0447\u0430\u0439\u043d\u044b\u0445 \u0441\u0438\u0442\u0443\u0430\u0446\u0438\u044f\u0445.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441\u0430\u043c\u043e\u0437\u0430\u0442\u0443\u0445\u0430\u044e\u0449\u0438\u043c\u0438. \u0412 \u0441\u043b\u0443\u0447\u0430\u0435 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0431\u044b\u0441\u0442\u0440\u043e \u0435\u0433\u043e \u043f\u043e\u0442\u0443\u0448\u0438\u0442\u044c \u0438 \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0437\u0430\u0434\u044b\u043c\u043b\u0435\u043d\u0438\u044f.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438<\/h3>\n\n\n\n<p>\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u0438 \u0443\u0441\u0438\u043b\u0438\u044f, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u0447\u0435\u043c \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u043c\u043e\u0434\u0435\u043b\u0438. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u044f\u0442\u044c \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438. \u0412\u043c\u0435\u0441\u0442\u043e \u044d\u0442\u043e\u0433\u043e \u0432\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u043e\u0441\u0440\u0435\u0434\u043e\u0442\u043e\u0447\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0438 \u0447\u0438\u0441\u0442\u043e\u0442\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u043d\u0430\u043b\u0438\u0447\u0438\u044f \u043f\u044b\u043b\u0438 \u0438\u043b\u0438 \u043c\u0443\u0441\u043e\u0440\u0430 \u0432\u043e\u043a\u0440\u0443\u0433 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u043e\u0442\u0432\u0435\u0440\u0441\u0442\u0438\u0439. \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u043f\u0440\u0438\u0437\u043d\u0430\u043a\u043e\u0432 \u0438\u0437\u043d\u043e\u0441\u0430 \u0438\u043b\u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439. \u0420\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u044b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u0441\u0432\u043e\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0442\u044c \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<p>\u0412\u043e\u0442 \u043f\u0440\u043e\u0441\u0442\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0446\u0430, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0432 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u0438 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0434\u0430\u0447\u0430<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041a\u0430\u043a \u0447\u0430\u0441\u0442\u043e<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0432\u0430\u0436\u043d\u043e<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u0430\u0436\u0434\u044b\u0435 6 \u043c\u0435\u0441\u044f\u0446\u0435\u0432<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u044f\u0442\u043d\u0430, \u043c\u0443\u0441\u043e\u0440 \u0438\u043b\u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0427\u0438\u0441\u0442\u044b\u0435 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043e\u0442\u0432\u0435\u0440\u0441\u0442\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041a\u0430\u0436\u0434\u044b\u0435 3 \u043c\u0435\u0441\u044f\u0446\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0415\u0436\u0435\u0433\u043e\u0434\u043d\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0417\u0430\u0449\u0438\u0442\u0430 \u0442\u0435\u0441\u0442\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0415\u0436\u0435\u0433\u043e\u0434\u043d\u043e<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041f\u0440\u043e\u0432\u0435\u0440\u044f\u0435\u0442 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0414\u043b\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u043e\u043a \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440. \u0411\u044b\u0441\u0442\u0440\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u043c \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430 \u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u0435\u0432.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0421\u043e\u0432\u0435\u0442\u044b \u043f\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435<\/h3>\n\n\n\n<p>\u0412\u044b \u0445\u043e\u0442\u0438\u0442\u0435, \u0447\u0442\u043e\u0431\u044b \u0432\u0430\u0448 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0440\u0430\u0431\u043e\u0442\u0430\u043b \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0441 \u0441\u0430\u043c\u043e\u0433\u043e \u043f\u0435\u0440\u0432\u043e\u0433\u043e \u0434\u043d\u044f. \u041d\u0430\u0447\u043d\u0438\u0442\u0435 \u0441 \u043e\u0446\u0435\u043d\u043a\u0438 \u0432\u0430\u0448\u0438\u0445 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0435\u0439 \u0432 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0438, \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u0432\u044b\u0431\u0438\u0440\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u043c\u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0442\u0438\u043f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0432\u0430\u0448\u0438\u043c \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u043c \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438. \u0421\u043e\u0437\u0434\u0430\u0439\u0442\u0435 \u043f\u0440\u043e\u0447\u043d\u0443\u044e \u043e\u0441\u043d\u043e\u0432\u0443 \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438 \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u0438\u044f \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438. \u041e\u0431\u0440\u0430\u0449\u0430\u0439\u0442\u0435\u0441\u044c \u0441 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e\u043c \u043e\u0441\u0442\u043e\u0440\u043e\u0436\u043d\u043e \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0438, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439.<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0439 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u0435 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u0435 \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>\u041f\u0435\u0440\u0435\u0434 \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043e\u0446\u0435\u043d\u0438\u0442\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u0438 \u043c\u0435\u0442\u043e\u0434 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f.<\/p><\/li><li><p>\u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u0439 \u0442\u0438\u043f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435 \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p><\/li><li><p>\u0421\u043e\u043e\u0440\u0443\u0434\u0438\u0442\u0435 \u043f\u0440\u043e\u0447\u043d\u043e\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u043b\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438 \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0430\u0446\u0438\u0438 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0439.<\/p><\/li><li><p>\u0412\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0438 \u043e\u0431\u0440\u0430\u0449\u0430\u0439\u0442\u0435\u0441\u044c \u0441 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u043c \u043e\u0441\u0442\u043e\u0440\u043e\u0436\u043d\u043e, \u0447\u0442\u043e\u0431\u044b \u043d\u0435 \u043f\u043e\u0432\u0440\u0435\u0434\u0438\u0442\u044c \u0435\u0433\u043e.<\/p><\/li><li><p>\u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u044b \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0438 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430.<\/p><\/li>\n<\/ol>\n\n\n\n<p>\u0412\u0441\u0435\u0433\u0434\u0430 \u0441\u043b\u0435\u0434\u0443\u0439\u0442\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u043c \u043f\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435, \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u043c \u0432 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f. \u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u043f\u043b\u043e\u0442\u043d\u043e \u0437\u0430\u0442\u044f\u043d\u0443\u0442\u044b, \u0447\u0442\u043e\u0431\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u043f\u0430\u0434\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432. \u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0430\u0437\u043c\u0435\u0440\u0430, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043d\u0435\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432\u0430. \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u0437\u0430\u0449\u0438\u0442\u0443 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443 \u0438 \u0437\u0430\u0449\u0438\u0442\u0443 \u043e\u0442 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043a\u0430\u043a \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u0442\u0441\u044f.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0412\u044b\u043d\u043e\u0441\u043d\u0430\u044f \u043d\u0430\u0434\u043f\u0438\u0441\u044c:<\/strong> \u0422\u0449\u0430\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u0438 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u044b\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u043f\u043e\u043c\u043e\u0433\u0443\u0442 \u0432\u0430\u043c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0441\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b. \u0412\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0435\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u044f.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0412\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430<\/h3>\n\n\n\n<p>\u0412\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442\u0435 \u0437\u0430\u0449\u0438\u0449\u0430\u0442\u044c \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443, \u043a\u043e\u0433\u0434\u0430 \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u0442\u0435 <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0441\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a>. \u0412 \u044d\u0442\u0438\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043c\u0430\u0441\u043b\u043e \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0440\u0438\u0441\u043a \u0443\u0442\u0435\u0447\u0435\u043a \u0438 \u0440\u0430\u0437\u043b\u0438\u0432\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0447\u0430\u0441\u0442\u043e \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u044f\u0442 \u0441 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438. \u0412\u0430\u043c \u043d\u0435 \u043d\u0443\u0436\u043d\u043e \u0431\u0435\u0441\u043f\u043e\u043a\u043e\u0438\u0442\u044c\u0441\u044f \u043e \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0438 \u043f\u043e\u0447\u0432\u044b \u0438\u043b\u0438 \u0432\u043e\u0434\u044b \u0432 \u0441\u043b\u0443\u0447\u0430\u0435 \u0432\u044b\u0445\u043e\u0434\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f. \u0412 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0442\u0432\u0435\u0440\u0434\u044b\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0433\u043e\u0440\u044e\u0447\u0438\u0445 \u0438\u043b\u0438 \u0442\u043e\u043a\u0441\u0438\u0447\u043d\u044b\u0445 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0435\u0439. \u042d\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0432\u0430\u0448\u0435 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u0435 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c \u0438 \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0435\u0442 \u0447\u0438\u0441\u0442\u043e\u0442\u0443 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u044b \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0435 \u0432\u0435\u0440\u043e\u044f\u0442\u043d\u043e\u0441\u0442\u044c \u0443\u0442\u0435\u0447\u043a\u0438 \u043c\u0430\u0441\u043b\u0430.<\/p><\/li><li><p>\u0412\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442\u0435 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0435 \u043f\u043e\u0447\u0432\u044b \u0438 \u0432\u043e\u0434\u044b.<\/p><\/li><li><p>\u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0430\u0431\u043e\u0442\u044b \u0441 \u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u044f\u043c\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u2014 \u0440\u0430\u0437\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u0434\u043b\u044f \u043c\u0435\u0441\u0442, \u0433\u0434\u0435 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0433\u043b\u0430\u0432\u043d\u044b\u043c \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442\u043e\u043c.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b<\/h3>\n\n\n\n<p>\u0412\u044b \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044e \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0438 \u043f\u043b\u0430\u043d\u0435\u0442\u044b, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u042d\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0432\u044b \u043d\u0435 \u043f\u043e\u0434\u0432\u0435\u0440\u0433\u0430\u0435\u0442\u0435\u0441\u044c \u0440\u0438\u0441\u043a\u0443 \u0443\u0442\u0435\u0447\u043a\u0438. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0442\u0432\u0435\u0440\u0434\u044b\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0430\u044f \u0441\u043c\u043e\u043b\u0430 \u0438\u043b\u0438 \u0441\u043c\u043e\u043b\u0430. \u042d\u0442\u0438 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u043d\u0435 \u043d\u0430\u043d\u043e\u0441\u044f\u0442 \u0432\u0440\u0435\u0434\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435 \u0438 \u0447\u0430\u0441\u0442\u043e \u043f\u043e\u0434\u043b\u0435\u0436\u0430\u0442 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u043a\u0435. \u041c\u043d\u043e\u0433\u0438\u0435 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 \u0432 \u043d\u0430\u0441\u0442\u043e\u044f\u0449\u0435\u0435 \u0432\u0440\u0435\u043c\u044f \u0438\u0441\u0441\u043b\u0435\u0434\u0443\u044e\u0442 \u043d\u043e\u0432\u044b\u0435 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0447\u0442\u043e\u0431\u044b \u0441\u0434\u0435\u043b\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0435\u0449\u0435 \u0431\u043e\u043b\u0435\u0435 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u043c\u0438. \u0412\u044b \u0442\u0430\u043a\u0436\u0435 \u043c\u043e\u0436\u0435\u0442\u0435 \u043d\u0430\u0431\u043b\u044e\u0434\u0430\u0442\u044c \u0441\u0442\u0440\u0435\u043c\u043b\u0435\u043d\u0438\u0435 \u043a \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044e \u0438 \u043f\u0440\u0435\u0432\u044b\u0448\u0435\u043d\u0438\u044e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u043e\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u043e\u0437\u0434\u0443\u0448\u043d\u043e\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0436\u0438\u0434\u043a\u0438\u0445 \u043e\u0442\u0445\u043e\u0434\u043e\u0432.<\/p><\/li><li><p>\u042d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0430\u044f \u0438 \u0441\u043c\u043e\u043b\u044f\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0430 \u0438 \u043f\u043e\u0434\u043b\u0435\u0436\u0438\u0442 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u043a\u0435.<\/p><\/li><li><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u0443\u043c\u0435\u043d\u044c\u0448\u0438\u0442\u044c \u0432\u0430\u0448 \u0443\u0433\u043b\u0435\u0440\u043e\u0434\u043d\u044b\u0439 \u0441\u043b\u0435\u0434.<\/p><\/li>\n<\/ul>\n\n\n\n<p>\u0412\u044b \u0438\u0433\u0440\u0430\u0435\u0442\u0435 \u0432\u0430\u0436\u043d\u0443\u044e \u0440\u043e\u043b\u044c \u0432 \u0444\u043e\u0440\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438 \u0431\u043e\u043b\u0435\u0435 \u0447\u0438\u0441\u0442\u043e\u0433\u043e \u0431\u0443\u0434\u0443\u0449\u0435\u0433\u043e, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u043e\u0435 \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f<\/h3>\n\n\n\n<p>\u0412\u0430\u043c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0437\u043d\u0430\u0442\u044c, \u0447\u0442\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0434\u043e\u043b\u0436\u043d\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u0441\u0442\u0440\u043e\u0433\u0438\u043c \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b. \u042d\u0442\u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u044e\u0442, \u0447\u0442\u043e \u0432\u0430\u0448\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u0434\u043b\u044f \u043b\u044e\u0434\u0435\u0439 \u0438 \u043f\u043b\u0430\u043d\u0435\u0442\u044b. \u0412 \u0442\u0430\u0431\u043b\u0438\u0446\u0435 \u043d\u0438\u0436\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u0430\u0436\u043d\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044e:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u041c\u042d\u041a<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b \u0441\u043e\u0431\u043b\u044e\u0434\u0430\u0435\u0442\u0435 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0440\u0430\u0432\u0438\u043b\u0430 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043e\u0445\u0440\u0430\u043d\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b, \u0441\u043b\u0435\u0434\u0443\u044f \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u044f\u043c IEC.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0435 \u043c\u0430\u0441\u043b\u0430<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0442\u0435\u043f\u0435\u0440\u044c \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430\u0442\u0443\u0440\u0430\u043b\u044c\u043d\u044b\u0445 \u044d\u0444\u0438\u0440\u043e\u0432 \u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0447\u0438\u0441\u0442\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c RoHS<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u0432\u0430\u0448\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p>\u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0431\u044b\u0442\u044c \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u0447\u0442\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u044d\u0442\u0438\u043c \u043f\u0440\u0430\u0432\u0438\u043b\u0430\u043c. \u042d\u0442\u043e \u0434\u0430\u0435\u0442 \u0432\u0430\u043c \u0443\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u0432\u0430\u0448\u0435\u043c\u0443 \u0431\u0438\u0437\u043d\u0435\u0441\u0443 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c. <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/\">\u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0446\u0435\u043b\u0438<\/a>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0412\u044b\u043d\u043e\u0441\u043d\u0430\u044f \u043d\u0430\u0434\u043f\u0438\u0441\u044c:<\/strong> \u0412\u044b\u0431\u0438\u0440\u0430\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430, \u0432\u044b \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u0435\u0442\u0435 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u043d\u0430 \u0440\u0430\u0431\u043e\u0447\u0435\u043c \u043c\u0435\u0441\u0442\u0435 \u0438 \u0443\u043b\u0443\u0447\u0448\u0435\u043d\u0438\u044e \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0438 \u0434\u043b\u044f \u0432\u0441\u0435\u0445.<\/p><\/blockquote>\n\n\n\n<p>\u0422\u0435\u043f\u0435\u0440\u044c \u0432\u044b \u0437\u043d\u0430\u0435\u0442\u0435, \u0447\u0442\u043e \u0432 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043c\u043e\u043b\u0430. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0435, \u0447\u0438\u0441\u0442\u043e\u0435 \u0438 \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0435\u0435 \u043e\u0441\u043e\u0431\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u0432\u0430\u0448\u0438\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u0412\u044b \u0438\u0437\u0431\u0435\u0433\u0430\u0435\u0442\u0435 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f \u0438 \u0443\u0442\u0435\u0447\u043a\u0438 \u043c\u0430\u0441\u043b\u0430.<\/p><\/li><li><p>\u0412\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442\u0435 \u0437\u0430\u0449\u0438\u0449\u0430\u0442\u044c \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0443\u044e \u0441\u0440\u0435\u0434\u0443.<\/p><\/li><li><p>\u0412\u044b \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u0435 \u0432\u0440\u0435\u043c\u044f \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\u0421\u043e\u0432\u0435\u0442:<\/strong> \u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0432 \u0432\u0430\u0448\u0435\u043c \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0435. \u0415\u0441\u043b\u0438 \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u0430 \u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0433\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f, \u043e\u0431\u0440\u0430\u0442\u0438\u0442\u0435\u0441\u044c \u043a \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u043c\u0443 \u044d\u043a\u0441\u043f\u0435\u0440\u0442\u0443 \u043f\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u043a\u0435 \u0438\u043b\u0438 \u0438\u0437\u0443\u0447\u0438\u0442\u0435 \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0432\u044b\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0430.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0412 \u0447\u0435\u043c \u0437\u0430\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u0441\u0443\u0445\u0438\u043c\u0438 \u0438 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438?<\/h3>\n\n\n\n<p>\u0412\u044b \u0443\u0432\u0438\u0434\u0438\u0442\u0435, \u0447\u0442\u043e <a target=\"_blank\" href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\">\u0441\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043c\u043e\u043b\u0443 \u0434\u043b\u044f \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f. \u041c\u0430\u0441\u043b\u044f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u043c\u0430\u0441\u043b\u043e. \u0421\u0443\u0445\u0438\u0435 \u043c\u043e\u0434\u0435\u043b\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043b\u0443\u0447\u0448\u0443\u044e \u043f\u043e\u0436\u0430\u0440\u043d\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0435\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435?<\/h3>\n\n\n\n<p>\u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043c\u043e\u0436\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435. \u0412\u0441\u0435\u0433\u0434\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0439\u0442\u0435 \u0443\u043a\u0430\u0437\u0430\u043d\u043d\u044b\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u043e \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u0438 \u043a \u043f\u043e\u0433\u043e\u0434\u043d\u044b\u043c \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u043c. \u0414\u043b\u044f \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0439 \u043a\u043e\u0436\u0443\u0445.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0421\u043a\u043e\u043b\u044c\u043a\u043e \u0441\u043b\u0443\u0436\u0438\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430?<\/h3>\n\n\n\n<p>\u041f\u0440\u0438 \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0435\u043c \u0443\u0445\u043e\u0434\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0442\u044c \u043e\u0442 20 \u0434\u043e 30 \u043b\u0435\u0442. \u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043c\u043e\u0434\u0435\u043b\u0438 \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u0430\u0436\u0435 \u0434\u043e\u043b\u044c\u0448\u0435.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0428\u0443\u043c\u044f\u0449\u0438\u0435 \u043b\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430?<\/h3>\n\n\n\n<p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u0431\u043e\u043b\u044c\u0448\u0435 \u0448\u0443\u043c\u0430, \u0447\u0435\u043c \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0435. \u0412\u044b \u043c\u043e\u0436\u0435\u0442\u0435 \u0443\u043c\u0435\u043d\u044c\u0448\u0438\u0442\u044c \u0448\u0443\u043c, \u0440\u0430\u0437\u043c\u0435\u0441\u0442\u0438\u0432 \u0438\u0445 \u0432 \u0437\u0432\u0443\u043a\u043e\u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0438\u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u0432\u0438\u0431\u0440\u043e\u043f\u043e\u0433\u043b\u043e\u0449\u0430\u044e\u0449\u0438\u0435 \u043f\u0440\u043e\u043a\u043b\u0430\u0434\u043a\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0422\u0440\u0435\u0431\u0443\u044e\u0442 \u043b\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f?<\/h3>\n\n\n\n<p>\u0422\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u0431\u0430\u0437\u043e\u0432\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435. \u041e\u0447\u0438\u0441\u0442\u0438\u0442\u0435 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043e\u0442\u0432\u0435\u0440\u0441\u0442\u0438\u044f, \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0438 \u043e\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e. \u041f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u044f\u0442\u044c \u043c\u0430\u0441\u043b\u043e \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u0413\u0434\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430?<\/h3>\n\n\n\n<p>\u0412 \u0431\u043e\u043b\u044c\u043d\u0438\u0446\u0430\u0445, \u0448\u043a\u043e\u043b\u0430\u0445, \u0442\u043e\u0440\u0433\u043e\u0432\u044b\u0445 \u0446\u0435\u043d\u0442\u0440\u0430\u0445 \u0438 \u043e\u0444\u0438\u0441\u0430\u0445 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u041e\u043d\u0438 \u0445\u043e\u0440\u043e\u0448\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0438 \u0432 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0432\u0430\u0436\u043d\u0430 \u043f\u043e\u0436\u0430\u0440\u043d\u0430\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u042f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043b\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u043c\u0438?<\/h3>\n\n\n\n<p>\u0412\u044b \u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u0435, \u0432\u044b\u0431\u0438\u0440\u0430\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u041e\u043d\u0438 \u043d\u0435 \u043f\u0440\u043e\u0442\u0435\u043a\u0430\u044e\u0442 \u0438 \u043d\u0435 \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u0442 \u0432\u0440\u0435\u0434\u043d\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432. \u0411\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u0434\u0435\u0442\u0430\u043b\u0435\u0439 \u043f\u043e\u0434\u043b\u0435\u0436\u0430\u0442 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0440\u0430\u0431\u043e\u0442\u043a\u0435.<\/p>\n\n\n\n\n<p><strong>\u0421\u0441\u044b\u043b\u043a\u0430 \u043d\u0430 \u0430\u0432\u0442\u043e\u0440\u0438\u0442\u0435\u0442:<\/strong> \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0438 \u0442\u0435\u0441\u0442\u043e\u0432\u044b\u0439 \u043a\u043e\u043d\u0442\u0435\u043a\u0441\u0442 \u0441\u043c. <a href=\"https:\/\/webstore.iec.ch\/publication\/599\" target=\"_blank\" rel=\"noopener\">\u0421\u0442\u0440\u0430\u043d\u0438\u0446\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438 IEC 60076<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0441\u0443\u0445\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u043e\u0437\u0434\u0443\u0445 \u0438\u043b\u0438 \u0441\u043c\u043e\u043b\u0443 \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0431\u043e\u043b\u0435\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u0443\u044e \u0438 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u043d\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0431\u0435\u0437 \u0443\u0442\u0435\u0447\u0435\u043a \u043c\u0430\u0441\u043b\u0430 \u0438 \u0440\u0438\u0441\u043a\u0430 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f.<\/p>","protected":false},"author":3,"featured_media":1578,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-1579","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1579","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=1579"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1579\/revisions"}],"predecessor-version":[{"id":3638,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/1579\/revisions\/3638"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/1578"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=1579"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=1579"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=1579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}