{"id":2126,"date":"2025-12-16T12:58:10","date_gmt":"2025-12-16T12:58:10","guid":{"rendered":"https:\/\/xbrele.com\/?p=2126"},"modified":"2026-04-07T15:12:45","modified_gmt":"2026-04-07T15:12:45","slug":"sf6-load-break-switch-working-principle","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/sf6-load-break-switch-working-principle\/","title":{"rendered":"\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 SF6 (LBS)? \u041e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e"},"content":{"rendered":"<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430 SF6? \u041e\u0431\u044a\u044f\u0441\u043d\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0439 \u043c\u0435\u0436\u0434\u0443 LBS \u0438 VCB\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/fvuUe-9gqZY?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #2c3e50; padding: 20px; margin: 20px 0; font-family: sans-serif; box-shadow: 0 2px 4px rgba(0,0,0,0.05);\"> <h3 style=\"color: #2c3e50; margin-top: 0; display: flex; align-items: center;\"> <span style=\"font-size: 1.2em; margin-right: 10px;\"><\/span> \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0432\u044b\u0432\u043e\u0434\u044b \u043f\u043e \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0438\u0438 <\/h3> <ul style=\"list-style-type: none; padding-left: 0; margin-bottom: 0;\"> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 \u0420\u0430\u0437\u043b\u0438\u0447\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 LBS \u0438 VCB:<\/strong> LBS \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d \u0434\u043b\u044f <em>\u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439<\/em> (\u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0442\u043e\u043a\u043e\u0432), \u0442\u043e\u0433\u0434\u0430 \u043a\u0430\u043a VCB \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f <em>\u0437\u0430\u0449\u0438\u0442\u043d\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e<\/em> \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043c\u0430\u0441\u0441\u0438\u0432\u043d\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. <\/li> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 \u041b\u043e\u0433\u0438\u043a\u0430 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0441 3 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u043c\u0438:<\/strong> \u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 RMU \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u043c\u0443\u044e \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c (\u0412\u041a\u041b \u2192 \u0412\u042b\u041a\u041b \u2192 \u0417\u0410\u0417\u0415\u041c\u041b\u0415\u041d\u0418\u0415), \u0447\u0442\u043e\u0431\u044b \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0447\u0435\u043b\u043e\u0432\u0435\u0447\u0435\u0441\u043a\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435 \u043b\u0438\u043d\u0438\u0438 \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c. <\/li> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 \u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439:<\/strong> \u041f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 LBS \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u0442\u044c \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043e\u043d \u043f\u043e\u0447\u0442\u0438 \u0432\u0441\u0435\u0433\u0434\u0430 \u0441\u043e\u0447\u0435\u0442\u0430\u0435\u0442\u0441\u044f \u0441 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f\u043c\u0438 HRC (\u043a\u043e\u043c\u0431\u0438\u043d\u0430\u0446\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0438 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f) \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432. <\/li> <li> <strong>\ud83d\udd39 \u0423\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b:<\/strong> \u041f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0441\u0442\u0440\u043e\u0433\u043e \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u044e\u0442\u0441\u044f <strong>\u041c\u042d\u041a 62271-103<\/strong> (\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438) \u0438 <strong>\u041c\u042d\u041a 62271-105<\/strong> (\u041a\u043e\u043c\u0431\u0438\u043d\u0430\u0446\u0438\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u0438 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439). <\/li> <\/ul> <\/div> <!-- END HTML BLOCK -->\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-introduction-the-lbs-vs-vcb-dilemma-in-network-design\">1. \u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435: \u0414\u0438\u043b\u0435\u043c\u043c\u0430 LBS \u043f\u0440\u043e\u0442\u0438\u0432 VCB \u0432 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438 \u0441\u0435\u0442\u0435\u0439<\/h2>\n\n\n\n<p>\u0418\u043d\u0436\u0435\u043d\u0435\u0440\u044b, \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u044e\u0449\u0438\u0435 \u043e\u0434\u043d\u043e\u043b\u0438\u043d\u0435\u0439\u043d\u0443\u044e \u0441\u0445\u0435\u043c\u0443 (SLD) \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f, \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e \u0441\u0442\u0430\u043b\u043a\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0441 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c\u044e \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u044f \u0440\u0435\u0448\u0435\u043d\u0438\u044f: <strong>\u0413\u0434\u0435 \u043f\u0440\u043e\u0445\u043e\u0434\u0438\u0442 \u0433\u0440\u0430\u043d\u044c \u043c\u0435\u0436\u0434\u0443 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u043c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (LBS) \u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u043c (VCB)?<\/strong><\/p>\n\n\n\n<p>\u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u043e \u043e\u043d\u0438 \u0447\u0430\u0441\u0442\u043e \u0432\u044b\u0433\u043b\u044f\u0434\u044f\u0442 \u043e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u043e \u0432 \u0440\u0430\u0441\u043f\u0438\u0441\u0430\u043d\u0438\u0438 \u043f\u0430\u043d\u0435\u043b\u0435\u0439, \u043e\u0431\u044b\u0447\u043d\u043e \u0440\u0430\u0441\u043f\u043e\u043b\u0430\u0433\u0430\u044f\u0441\u044c \u0440\u044f\u0434\u043e\u043c \u0441 \u0434\u0440\u0443\u0433\u0438\u043c\u0438 <a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/switchgear-components\/\"><strong>\u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/strong><\/a>. \u041e\u0434\u043d\u0430\u043a\u043e \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0432 \u0434\u0430\u043d\u043d\u043e\u043c \u0441\u043b\u0443\u0447\u0430\u0435 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0435 \u043f\u0440\u043e\u0441\u0442\u043e \u0441\u0435\u043c\u0430\u043d\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043e\u0448\u0438\u0431\u043a\u043e\u0439, \u0430 \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u043c \u0440\u0438\u0441\u043a\u043e\u043c. \u0427\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u0430\u044f \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f VCB \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043d\u0435\u043e\u043f\u0440\u0430\u0432\u0434\u0430\u043d\u043d\u043e\u043c\u0443 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044e \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u043f\u0440\u043e\u0435\u043a\u0442 (\u0447\u0430\u0441\u0442\u043e \u043d\u0430 300%), \u0430 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f LBS \u0432 \u0440\u043e\u043b\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0441\u0442\u0430\u0432\u0438\u0442 \u043f\u043e\u0434 \u0443\u0433\u0440\u043e\u0437\u0443 \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u0441\u0431\u043e\u044e.<\/p>\n\n\n\n<p>\u042d\u0442\u043e \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043e\u0441\u043d\u043e\u0432\u043e\u043f\u043e\u043b\u0430\u0433\u0430\u044e\u0449\u0438\u043c \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (\u0421\u041d):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The <a href=\"https:\/\/xbrele.com\/ru\/what-is-vacuum-circuit-breaker-working-principle\/\"><strong>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB)<\/strong><\/a> \u044d\u0442\u043e \u0432\u0430\u0448\u0430 \u0441\u0435\u0442\u043a\u0430 <strong>\u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0437\u0430\u0449\u0438\u0442\u044b<\/strong>\u2014\u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043c\u0430\u0441\u0441\u0438\u0432\u043d\u044b\u0445 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0437\u0430\u043c\u043a\u043d\u0443\u0442\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, 20 \u043a\u0410, 31,5 \u043a\u0410).<\/li>\n\n\n\n<li>The <a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/sf6-load-break-switch\/\"><strong>\u0420\u0430\u0437\u043c\u044b\u043a\u0430\u0442\u0435\u043b\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 SF6<\/strong><\/a> \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f <strong>\u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0441\u0435\u0442\u043a\u043e\u0439<\/strong>\u2014\u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d \u0434\u043b\u044f \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0442\u043e\u043a\u043e\u0432 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0443\u0447\u0430\u0441\u0442\u043a\u043e\u0432 \u0441\u0435\u0442\u0438 \u0434\u043b\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0432\u0438\u0434\u0438\u043c\u043e\u0433\u043e \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u044f.<\/li>\n<\/ul>\n\n\n\n<p>\u0412 \u044d\u0442\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u0432\u044b\u0445\u043e\u0434\u0438\u0442 \u0437\u0430 \u0440\u0430\u043c\u043a\u0438 \u0431\u0430\u0437\u043e\u0432\u044b\u0445 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0439 \u0438 \u0438\u0441\u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u0443\u044e \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u044c SF6 LBS: \u0435\u0433\u043e \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u044e\u044e \u0444\u0438\u0437\u0438\u043a\u0443, \u043f\u043e\u0447\u0435\u043c\u0443 \u043e\u043d \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u043c \u0434\u043b\u044f \u043a\u043e\u043b\u044c\u0446\u0435\u0432\u044b\u0445 \u0433\u043b\u0430\u0432\u043d\u044b\u0445 \u0431\u043b\u043e\u043a\u043e\u0432 (RMU) \u0438 \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0442\u044c \u0435\u0433\u043e \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 <strong>\u041c\u042d\u041a 62271<\/strong> \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-defining-the-sf6-load-break-switch-iec-62271-103\">2. \u041e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0441 SF6 (IEC 62271-103)<\/h2>\n\n\n\n<p>\u0410 <strong>\u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 SF6<\/strong> \u2014 \u044d\u0442\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0435\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u0442\u044c, \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u0438 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u0442\u044c \u0442\u043e\u043a \u0432 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0440\u0430\u0431\u043e\u0442\u044b \u0446\u0435\u043f\u0438. \u0412\u0430\u0436\u043d\u043e \u043e\u0442\u043c\u0435\u0442\u0438\u0442\u044c, \u0447\u0442\u043e \u0441\u0442\u0440\u043e\u0433\u043e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043e <strong>\u041c\u042d\u041a 62271-103<\/strong>, \u043e\u043d \u0442\u0430\u043a\u0436\u0435 \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u0441\u043f\u043e\u0441\u043e\u0431\u0435\u043d <strong>\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435<\/strong> \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u0440\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 (\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043d\u0430 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c), \u0434\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u044d\u0442\u043e \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e <strong>\u043f\u0435\u0440\u0435\u0440\u044b\u0432<\/strong> \u044d\u0442\u0430 \u0432\u0438\u043d\u0430.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-engineering-reality-of-load-breaking\">\u0418\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u0430\u044f \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u201c\u0440\u0430\u0437\u0433\u0440\u0443\u0437\u043a\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438\u201d<\/h3>\n\n\n\n<p>\u0422\u0435\u0440\u043c\u0438\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u0447\u0430\u0441\u0442\u043e \u0441\u0431\u0438\u0432\u0430\u0435\u0442 \u0441 \u0442\u043e\u043b\u043a\u0443 \u043c\u043e\u043b\u043e\u0434\u044b\u0445 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043e\u0432. \u0414\u0430\u0432\u0430\u0439\u0442\u0435 \u0440\u0430\u0437\u0431\u0435\u0440\u0435\u043c\u0441\u044f \u0441 \u0442\u0440\u0435\u043c\u044f \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u043c\u0438 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044f\u043c\u0438:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (\u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a):<\/strong> \u041e\u043d \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, 630 \u0410 \u043f\u0440\u0438 24 \u043a\u0412). \u0420\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043c\u043e\u0449\u043d\u0443\u044e \u0434\u0443\u0433\u0443. \u0411\u0435\u0437 \u0430\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u0433\u0430\u0441\u044f\u0449\u0435\u0433\u043e \u0432\u0435\u0449\u0435\u0441\u0442\u0432\u0430, \u0442\u0430\u043a\u043e\u0433\u043e \u043a\u0430\u043a SF6, \u044d\u0442\u0430 \u0434\u0443\u0433\u0430 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u043b\u0430 \u0431\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044f \u0442\u043e\u043a \u0438 \u0440\u0430\u0437\u0440\u0443\u0448\u0430\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c.<\/li>\n\n\n\n<li><strong>\u0421\u043e\u0437\u0434\u0430\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 (\u0441\u043e\u0437\u0434\u0430\u043d\u0438\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f):<\/strong> \u042d\u0442\u043e \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438. \u0415\u0441\u043b\u0438 \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440 \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u043e \u0437\u0430\u043a\u0440\u043e\u0435\u0442 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430 \u0437\u0430\u043a\u043e\u0440\u043e\u0447\u0435\u043d\u043d\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435, \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0435 \u0434\u043e\u043b\u0436\u0435\u043d \u0432\u0437\u0440\u044b\u0432\u0430\u0442\u044c\u0441\u044f. \u041e\u043d \u0434\u043e\u043b\u0436\u0435\u043d \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043e\u0433\u0440\u043e\u043c\u043d\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0435 \u0441\u0438\u043b\u044b \u0438 \u0442\u0435\u043f\u043b\u043e\u0432\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u043f\u0438\u043a\u043e\u0432\u044b\u0439 \u0442\u043e\u043a 50 \u043a\u0410) \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0434\u043b\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0432\u044b\u0448\u0435 \u043f\u043e \u0446\u0435\u043f\u0438.<\/li>\n\n\n\n<li><strong>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f (\u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0437\u0430\u0437\u043e\u0440):<\/strong> \u0412 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438 \u043e\u043d \u0434\u043e\u043b\u0436\u0435\u043d \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0442\u044c \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0437\u0430\u0437\u043e\u0440, \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b\u0430, \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0435\u0433\u043e \u043d\u0438\u0436\u0435 \u043f\u043e \u0446\u0435\u043f\u0438, \u0441 \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u043e\u0439 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0439 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e (BIL).<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-hard-limit-it-is-not-a-breaker\">\u0416\u0435\u0441\u0442\u043a\u0438\u0439 \u043b\u0438\u043c\u0438\u0442: \u044d\u0442\u043e \u043d\u0435 \u043f\u0440\u0435\u0434\u0435\u043b<\/h3>\n\n\n\n<p>\u041e\u0447\u0435\u043d\u044c \u0432\u0430\u0436\u043d\u043e \u043f\u043e\u043d\u0438\u043c\u0430\u0442\u044c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f: <strong>LBS \u043d\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435.<\/strong> \u0421\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0438 \u044d\u043d\u0435\u0440\u0433\u0438\u044f \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0441 \u043a\u0438\u043b\u043e\u0430\u043c\u043f\u0435\u0440\u0430\u043c\u0438 \u0432 \u0441\u043b\u0443\u0447\u0430\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438. \u041f\u043e\u043f\u044b\u0442\u043a\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u044c LBS \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u0442 \u043a \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u043c\u0443 \u0440\u0430\u0437\u0433\u043e\u043d\u0443 \u0438 \u0432\u0437\u0440\u044b\u0432\u0443 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u0430.<\/p>\n\n\n\n<p>\u041f\u043e\u044d\u0442\u043e\u043c\u0443 \u0431\u043b\u043e\u043a\u0438 LBS \u0432 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0444\u0438\u0434\u0435\u0440\u0430\u0445 \u0432\u0441\u0435\u0433\u0434\u0430 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432 \u043f\u0430\u0440\u0435 \u0441 <strong>\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 HRC<\/strong>. \u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0435\u0442 \u0440\u0443\u0447\u043d\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0412\u043d\u0435\u0448\u043d\u044f\u044f \u0441\u0441\u044b\u043b\u043a\u0430:<\/strong> \u0414\u043b\u044f \u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u043e\u0433\u043e \u043e\u0437\u043d\u0430\u043a\u043e\u043c\u043b\u0435\u043d\u0438\u044f \u0441 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f\u043c\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u043c. <a href=\"https:\/\/www.electropedia.org\/iev\/iev.nsf\/display?openform&amp;ievref=441-14-10\" target=\"_blank\" rel=\"noopener\"><strong>IEC Electropedia (\u041c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u043b\u043e\u0432\u0430\u0440\u044c)<\/strong><\/a> \u0434\u043b\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u0439 \u0442\u0435\u0440\u043c\u0438\u043d\u043e\u043b\u043e\u0433\u0438\u0438 \u043f\u043e \u201c\u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u043c-\u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044f\u043c\u201d.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-the-physics-of-sf6-why-it-dominated-for-40-years\">3. \u0424\u0438\u0437\u0438\u043a\u0430 SF6: \u043f\u043e\u0447\u0435\u043c\u0443 \u043e\u043d \u0434\u043e\u043c\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043b \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 40 \u043b\u0435\u0442<\/h2>\n\n\n\n<p>\u041f\u043e\u0447\u0435\u043c\u0443 \u043c\u044b \u0432\u0441\u0435 \u0435\u0449\u0435 \u043f\u043e\u043b\u0430\u0433\u0430\u0435\u043c\u0441\u044f \u043d\u0430 <strong>\u0413\u0435\u043a\u0441\u0430\u0444\u0442\u043e\u0440\u0438\u0434 \u0441\u0435\u0440\u044b (SF6)<\/strong> \u043d\u0435\u0441\u043c\u043e\u0442\u0440\u044f \u043d\u0430 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u044b\u0439 \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c? \u041f\u043e\u0442\u043e\u043c\u0443 \u0447\u0442\u043e \u0441 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0442\u043e\u0447\u043a\u0438 \u0437\u0440\u0435\u043d\u0438\u044f \u043e\u043d \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435 \u0438\u043c\u0435\u0435\u0442 \u0441\u0435\u0431\u0435 \u0440\u0430\u0432\u043d\u044b\u0445 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u0441\u0440\u0435\u0434\u044b \u0434\u043b\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0442\u043e\u043a\u0430 \u0432 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0432\u043e\u0437\u0434\u0443\u0445\u043e\u043c \u0438\u043b\u0438 \u043c\u0430\u0441\u043b\u043e\u043c.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-electronegativity-and-electron-attachment\">1. \u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0442\u0440\u0438\u0446\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u0438\u0432\u044f\u0437\u043a\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u043e\u0432<\/h3>\n\n\n\n<p>SF6 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u201c\u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0442\u0440\u0438\u0446\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u201d \u0433\u0430\u0437\u043e\u043c. \u042d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0435\u0433\u043e \u043c\u043e\u043b\u0435\u043a\u0443\u043b\u044b \u043e\u0431\u043b\u0430\u0434\u0430\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0430\u0444\u0444\u0438\u043d\u043d\u043e\u0441\u0442\u044c\u044e \u043a \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u044b\u043c \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u0430\u043c. \u041a\u043e\u0433\u0434\u0430 \u043e\u0431\u0440\u0430\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u0443\u0433\u0430 (\u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043f\u043e \u0441\u0443\u0442\u0438 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043f\u043e\u0442\u043e\u043a\u043e\u043c \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u043e\u0432), \u043c\u043e\u043b\u0435\u043a\u0443\u043b\u044b SF6 \u0437\u0430\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u044d\u0442\u0438 \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u044b, \u043e\u0431\u0440\u0430\u0437\u0443\u044f \u0442\u044f\u0436\u0435\u043b\u044b\u0435 \u043e\u0442\u0440\u0438\u0446\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0438\u043e\u043d\u044b:<\/p>\n\n\n\n<p style=\"text-align: center; font-family: 'Times New Roman', serif; font-size: 1.3em; margin: 20px 0;\"> SF<sub>6<\/sub> + e<sup>\u2013<\/sup> \u2192 SF<sub>6<\/sub><sup>\u2013<\/sup> <\/p>\n\n\n\n<p>\u042d\u0442\u0438 \u0442\u044f\u0436\u0435\u043b\u044b\u0435 \u0438\u043e\u043d\u044b \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u043c\u0435\u043d\u0435\u0435 \u043f\u043e\u0434\u0432\u0438\u0436\u043d\u044b, \u0447\u0435\u043c \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u044b, \u0447\u0442\u043e \u0440\u0435\u0437\u043a\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u0434\u0443\u0433\u043e\u0432\u043e\u0439 \u043f\u043b\u0430\u0437\u043c\u044b. \u042d\u0442\u043e\u0442 \u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u201c\u043b\u0438\u0448\u0430\u0435\u0442\u201d \u0434\u0443\u0433\u0443 \u0435\u0435 \u043f\u0440\u043e\u0432\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u043f\u0443\u0442\u0438.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-thermal-conductivity-at-high-temperatures\">2. \u0422\u0435\u043f\u043b\u043e\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430\u0445<\/h3>\n\n\n\n<p>SF6 \u043e\u0431\u043b\u0430\u0434\u0430\u0435\u0442 \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u043c \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u043e\u043c: \u0435\u0433\u043e \u0442\u0435\u043f\u043b\u043e\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u043e\u0441\u0442\u044c \u0440\u0435\u0437\u043a\u043e \u0432\u043e\u0437\u0440\u0430\u0441\u0442\u0430\u0435\u0442 \u043f\u0440\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430\u0445 \u0440\u0430\u0441\u043f\u0430\u0434\u0430 \u0434\u0443\u0433\u0438 (\u043e\u043a\u043e\u043b\u043e 2000\u20133000 \u041a). \u042d\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0435\u043c\u0443 \u043e\u0442\u0432\u043e\u0434\u0438\u0442\u044c \u0442\u0435\u043f\u043b\u043e \u043e\u0442 \u0437\u043e\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u0435\u0435, \u0447\u0435\u043c \u0432\u043e\u0437\u0434\u0443\u0445. \u0422\u0430\u043a\u043e\u0435 \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0434\u043b\u044f <strong>\u0414\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435<\/strong>\u2014\u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0435 \u0442\u043e\u0433\u043e, \u0447\u0442\u043e \u043a\u043e\u0433\u0434\u0430 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442 \u201c\u043d\u0443\u043b\u044f\u201d, \u0437\u0430\u0437\u043e\u0440 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0441\u0432\u043e\u044e \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0431\u044b\u0441\u0442\u0440\u0435\u0435, \u0447\u0435\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0434\u043d\u044f\u0442\u044c\u0441\u044f \u043f\u043e \u043d\u0435\u043c\u0443 (\u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-chemical-recombination\">3. \u0425\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0440\u0435\u043a\u043e\u043c\u0431\u0438\u043d\u0430\u0446\u0438\u044f<\/h3>\n\n\n\n<p>\u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 \u043c\u0430\u0441\u043b\u0430, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0440\u0430\u0437\u043b\u0430\u0433\u0430\u0435\u0442\u0441\u044f \u043d\u0430 \u0443\u0433\u043b\u0435\u0440\u043e\u0434\u043d\u044b\u0439 \u0448\u043b\u0430\u043c, \u0438\u043b\u0438 \u0432\u043e\u0437\u0434\u0443\u0445\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043e\u0431\u0440\u0430\u0437\u0443\u0435\u0442 \u043e\u0437\u043e\u043d, \u0433\u0430\u0437 SF6 \u0440\u0435\u043a\u043e\u043c\u0431\u0438\u043d\u0438\u0440\u0443\u0435\u0442 \u043f\u043e\u0441\u043b\u0435 \u043f\u043e\u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438.<\/p>\n\n\n\n<p style=\"text-align: center; font-family: 'Times New Roman', serif; font-size: 1.3em; margin: 20px 0;\"> SF<sub>6<\/sub> \u2194 S + 6F <\/p>\n\n\n\n<p>\u041f\u043e\u0441\u043b\u0435 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438 \u0430\u0442\u043e\u043c\u044b \u0441\u0435\u0440\u044b \u0438 \u0444\u0442\u043e\u0440\u0430 \u0432\u043d\u043e\u0432\u044c \u043e\u0431\u044a\u0435\u0434\u0438\u043d\u044f\u044e\u0442\u0441\u044f \u0432 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u044b\u0439 SF6. \u042d\u0442\u043e \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u043e \u201c\u0441\u0430\u043c\u043e\u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f\u201d \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u043e\u043c\u0443 LBS \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0431\u043e\u043b\u0435\u0435 20 \u043b\u0435\u0442 \u0431\u0435\u0437 \u043f\u043e\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u0433\u0430\u0437\u0430.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-the-design-logic-why-rmus-rely-on-lbs\">4. \u041b\u043e\u0433\u0438\u043a\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f: \u043f\u043e\u0447\u0435\u043c\u0443 RMU \u043f\u043e\u043b\u0430\u0433\u0430\u044e\u0442\u0441\u044f \u043d\u0430 LBS<\/h2>\n\n\n\n<p>\u0415\u0441\u043b\u0438 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/\"><strong>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB)<\/strong><\/a> \u043c\u043e\u0433\u0443\u0442 \u043e\u0431\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0442\u044c \u043a\u0430\u043a \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0442\u0430\u043a \u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438, \u043f\u043e\u0447\u0435\u043c\u0443 \u0431\u044b \u043d\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0438\u0445 \u043f\u043e\u0432\u0441\u0435\u043c\u0435\u0441\u0442\u043d\u043e? \u041e\u0442\u0432\u0435\u0442 \u043a\u0440\u043e\u0435\u0442\u0441\u044f \u0432 \u0442\u043e\u043f\u043e\u043b\u043e\u0433\u0438\u0438 \u0441\u0435\u0442\u0438 \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u043a\u0430\u043f\u0438\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u0437\u0430\u0442\u0440\u0430\u0442 (CAPEX).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-ring-topology-argument\">\u0410\u0440\u0433\u0443\u043c\u0435\u043d\u0442 \u043e \u043a\u043e\u043b\u044c\u0446\u0435\u0432\u043e\u0439 \u0442\u043e\u043f\u043e\u043b\u043e\u0433\u0438\u0438<\/h3>\n\n\n\n<p>\u0412\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043e\u0431\u044b\u0447\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u043a\u043e\u043b\u044c\u0446\u0435\u0432\u0443\u044e \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0443 \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0438\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u043e\u0441\u0442\u0438. \u0412 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u043c \u043a\u043e\u043b\u044c\u0446\u0435\u0432\u043e\u043c \u0433\u043b\u0430\u0432\u043d\u043e\u043c \u0431\u043b\u043e\u043a\u0435 (RMU) \u043c\u043e\u0436\u0435\u0442 \u0431\u044b\u0442\u044c \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f \u201cCCF\u201d: \u0434\u0432\u0430 \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0438 \u043e\u0434\u0438\u043d \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 (C-\u043c\u043e\u0434\u0443\u043b\u044c):<\/strong> \u041e\u043d\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u044f\u044e\u0442 RMU \u0441 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u043c \u043a\u043e\u043b\u044c\u0446\u043e\u043c \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0432 \u044d\u0442\u043e\u043c \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c \u043a\u043e\u043b\u044c\u0446\u0435 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441\u043e\u0431\u044b\u0442\u0438\u044f\u043c\u0438 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0435\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0431\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442\u0441\u044f \u0440\u0435\u043b\u0435 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u043e\u0439 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438. \u041b\u043e\u043a\u0430\u043b\u044c\u043d\u044b\u0439 RMU \u043d\u0435 \u0434\u043e\u043b\u0436\u0435\u043d \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u044d\u0442\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043b\u044c\u0446\u0430; \u043e\u043d \u0434\u043e\u043b\u0436\u0435\u043d \u0442\u043e\u043b\u044c\u043a\u043e \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0435\u043a\u0446\u0438\u044e. <em>\u043f\u043e\u0441\u043b\u0435<\/em> \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0438\u043b\u0430\u0441\u044c \u0438\u043b\u0438 \u043f\u0440\u043e\u0438\u0437\u043e\u0448\u043b\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f. <strong>LBS \u043e\u0442\u043b\u0438\u0447\u043d\u043e \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0441 \u044d\u0442\u043e\u0439 \u0444\u0443\u043d\u043a\u0446\u0438\u0435\u0439 \u043f\u0440\u0438 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 30% \u043e\u0442 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 VCB.<\/strong><\/li>\n\n\n\n<li><strong>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043d\u044b\u0439 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u044c (\u043c\u043e\u0434\u0443\u043b\u044c F):<\/strong> \u042d\u0442\u043e \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043b\u043e\u043a\u0430\u043b\u044c\u043d\u044b\u0439 <a href=\"https:\/\/xbrele.com\/ru\/distribution-transformer-guide\/\"><strong>\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440<\/strong><\/a> (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, 500 \u043a\u0412\u0410). \u0421\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043a\u043e\u043c\u0431\u0438\u043d\u0430\u0446\u0438\u044f LBS-Fuse \u0432 \u0434\u0430\u043d\u043d\u043e\u043c \u0441\u043b\u0443\u0447\u0430\u0435 \u0433\u043e\u0440\u0430\u0437\u0434\u043e \u0431\u043e\u043b\u0435\u0435 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u0430, \u0447\u0435\u043c \u043f\u043e\u043b\u043d\u043e\u0446\u0435\u043d\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u043e\u0442 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043d\u0430\u0431\u043b\u044e\u0434\u0430\u0435\u043c\u044b\u0445 \u043d\u0430 \u043a\u043b\u0435\u043c\u043c\u0430\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-footprint-advantage\">\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e Footprint<\/h3>\n\n\n\n<p>\u041f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0432\u0430\u043b\u044e\u0442\u043e\u0439 \u0432 \u0433\u043e\u0440\u043e\u0434\u0441\u043a\u043e\u0439 \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0435. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u0430\u044f \u0441\u0431\u043e\u0440\u043a\u0430 VCB \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0433\u0440\u043e\u043c\u043e\u0437\u0434\u043a\u0438\u0445 \u0440\u0430\u0431\u043e\u0447\u0438\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u0432 (\u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0445 \u0437\u0430\u0440\u044f\u0434\u043d\u044b\u0445 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439) \u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0431\u0443\u0442\u044b\u043b\u043e\u043a.<\/p>\n\n\n\n<p>SF6 LBS \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0433\u0430\u0437\u0430 (\u0432 2,5 \u0440\u0430\u0437\u0430 \u0432\u044b\u0448\u0435, \u0447\u0435\u043c \u0443 \u0432\u043e\u0437\u0434\u0443\u0445\u0430), \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043c\u0435\u0436\u0444\u0430\u0437\u043d\u044b\u0435 \u0437\u0430\u0437\u043e\u0440\u044b. \u042d\u0442\u043e \u0434\u0430\u0435\u0442 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u0442\u044c \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438. <strong>\u0413\u0430\u0437\u043e\u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e (GIS)<\/strong> \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043c\u0435\u0441\u0442\u0438\u0442\u044c\u0441\u044f \u0432 \u0443\u0437\u043a\u0438\u0445 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u043d\u0430 \u0442\u0440\u043e\u0442\u0443\u0430\u0440\u0430\u0445 \u0438\u043b\u0438 \u0431\u0430\u0448\u043d\u044f\u0445 \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0445 \u0442\u0443\u0440\u0431\u0438\u043d \u2014 \u043c\u0435\u0441\u0442\u0430\u0445, \u0433\u0434\u0435 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043f\u0440\u043e\u0441\u0442\u043e \u043d\u0435 \u043f\u043e\u043c\u0435\u0441\u0442\u044f\u0442\u0441\u044f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-operational-mechanics-puffer-vs-rotating-arc\">5. \u041c\u0435\u0445\u0430\u043d\u0438\u043a\u0430 \u0440\u0430\u0431\u043e\u0442\u044b: \u043f\u0443\u0444\u0444\u0435\u0440 \u043f\u0440\u043e\u0442\u0438\u0432 \u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0435\u0439\u0441\u044f \u0434\u0443\u0433\u0438<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram.webp\" alt=\"\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u044b\u0439 \u0447\u0435\u0440\u0442\u0435\u0436 \u043f\u043e\u043f\u0435\u0440\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0447\u0435\u043d\u0438\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430 \u0433\u0430\u0437\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 SF6. \u0412\u044b\u0441\u043e\u043a\u0430\u044f \u043a\u043e\u043d\u0442\u0440\u0430\u0441\u0442\u043d\u043e\u0441\u0442\u044c, \u0431\u0435\u043b\u044b\u0439 \u0444\u043e\u043d. \u0418\u043b\u043b\u044e\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u0432 \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u043e\u043c \u0441\u0442\u0438\u043b\u0435. \u041f\u043e\u043a\u0430\u0437\u0430\u043d\u044b \u0442\u0440\u0438 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f: 1. \u0417\u0430\u043c\u043a\u043d\u0443\u0442\u0430\u044f \u0446\u0435\u043f\u044c, 2. \u041e\u0442\u043a\u0440\u044b\u0442\u044b\u0439 \u0440\u0430\u0437\u0440\u044f\u0434\u043d\u0438\u043a, 3. \u041f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u0439 \u0437\u0430\u0437\u0435\u043c\u043b\u044f\u044e\u0449\u0438\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442. \u041d\u0430\u0437\u0432\u0430\u043d\u0438\u044f \u0434\u0435\u0442\u0430\u043b\u0435\u0439: &quot;\u041f\u043e\u0434\u0432\u0438\u0436\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442&quot;, &quot;\u041d\u0435\u043f\u043e\u0434\u0432\u0438\u0436\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442&quot;, &quot;\u0417\u0430\u0437\u0435\u043c\u043b\u044f\u044e\u0449\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c&quot;. \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439, \u0441\u0445\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439, \u0442\u043e\u0447\u043d\u044b\u0439 \u043b\u0438\u043d\u0435\u0439\u043d\u044b\u0439 \u0440\u0438\u0441\u0443\u043d\u043e\u043a.\" class=\"wp-image-2131\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u041a\u0430\u043a \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0433\u0430\u0441\u0438\u0442 \u0434\u0443\u0433\u0443? \u0414\u0435\u043b\u043e \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0432 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u043d\u043e \u0438 \u0432 \u0434\u0438\u043d\u0430\u043c\u0438\u043a\u0435 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0432\u043d\u0443\u0442\u0440\u0438 \u0433\u0430\u0437\u043e\u0432\u043e\u0433\u043e \u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technique-a-puffer-type-the-standard\">\u0422\u0435\u0445\u043d\u0438\u043a\u0430 A: \u0422\u0438\u043f \u00ab\u043f\u0443\u0444\u0444\u0435\u0440\u00bb (\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439)<\/h3>\n\n\n\n<p>\u042d\u0442\u043e \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u0430\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0434\u043b\u044f \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0421\u0436\u0430\u0442\u0438\u0435:<\/strong> \u041f\u0440\u0438 \u043e\u0442\u043f\u0443\u0441\u043a\u0430\u043d\u0438\u0438 \u0440\u0430\u0431\u043e\u0447\u0435\u0439 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u043f\u043e\u0440\u0448\u0435\u043d\u044c, \u043f\u0440\u0438\u043a\u0440\u0435\u043f\u043b\u0435\u043d\u043d\u044b\u0439 \u043a \u043f\u043e\u0434\u0432\u0438\u0436\u043d\u043e\u043c\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0443, \u0441\u0436\u0438\u043c\u0430\u0435\u0442 \u0433\u0430\u0437 SF6 \u0432\u043d\u0443\u0442\u0440\u0438 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0433\u043e \u0446\u0438\u043b\u0438\u043d\u0434\u0440\u0430.<\/li>\n\n\n\n<li><strong>\u0412\u044b\u043f\u0443\u0441\u043a:<\/strong> \u0412 \u0442\u043e\u0442 \u043c\u043e\u043c\u0435\u043d\u0442, \u043a\u043e\u0433\u0434\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u044e\u0442\u0441\u044f \u0438 \u043e\u0431\u0440\u0430\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u0443\u0433\u0430, \u0441\u043e\u043f\u043b\u043e \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u0442 \u0441\u0436\u0430\u0442\u044b\u0439 \u0433\u0430\u0437 \u0432 \u043e\u0441\u0435\u0432\u043e\u043c \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0438 \u0432\u0434\u043e\u043b\u044c \u0441\u0442\u043e\u043b\u0431\u0430 \u0434\u0443\u0433\u0438.<\/li>\n\n\n\n<li><strong>\u0412\u044b\u043c\u0438\u0440\u0430\u043d\u0438\u0435:<\/strong> \u0412\u044b\u0441\u043e\u043a\u043e\u0441\u043a\u043e\u0440\u043e\u0441\u0442\u043d\u043e\u0439 \u043f\u043e\u0442\u043e\u043a \u0433\u0430\u0437\u0430 \u0443\u0434\u043b\u0438\u043d\u044f\u0435\u0442 \u0434\u0443\u0433\u0443 \u0438 \u0431\u044b\u0441\u0442\u0440\u043e \u043e\u0445\u043b\u0430\u0436\u0434\u0430\u0435\u0442 \u0435\u0435, \u0434\u0435\u0438\u043e\u043d\u0438\u0437\u0438\u0440\u0443\u044f \u0437\u0430\u0437\u043e\u0440 \u0434\u043e \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043c\u043e\u0436\u0435\u0442 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c\u0441\u044f.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technique-b-rotating-arc-principle\">\u041c\u0435\u0442\u043e\u0434 B: \u041f\u0440\u0438\u043d\u0446\u0438\u043f \u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0435\u0439\u0441\u044f \u0434\u0443\u0433\u0438<\/h3>\n\n\n\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0439 \u0432 \u0431\u043e\u043b\u0435\u0435 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438\u043b\u0438 \u0432 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u0445 \u043c\u0430\u0440\u043a\u0430\u0445 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0432 \u0441\u0442\u0430\u0440\u044b\u0445 \u043c\u043e\u0434\u0435\u043b\u044f\u0445 Schneider Electric), \u044d\u0442\u043e\u0442 \u043c\u0435\u0442\u043e\u0434 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0441\u0430\u043c\u043e\u0439 \u0434\u0443\u0433\u0438.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u043e\u043b\u0435:<\/strong> \u0422\u043e\u043a, \u043f\u0440\u043e\u0442\u0435\u043a\u0430\u044e\u0449\u0438\u0439 \u0447\u0435\u0440\u0435\u0437 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u043f\u0440\u043e\u0445\u043e\u0434\u0438\u0442 \u0447\u0435\u0440\u0435\u0437 \u043a\u0430\u0442\u0443\u0448\u043a\u0443, \u0433\u0435\u043d\u0435\u0440\u0438\u0440\u0443\u044f \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u043e\u043b\u0435.<\/li>\n\n\n\n<li><strong>\u0421\u0438\u043b\u0430 \u041b\u043e\u0440\u0435\u043d\u0446\u0430:<\/strong> \u042d\u0442\u043e \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u043e\u043b\u0435 \u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0441\u0438\u043b\u0443 \u043d\u0430 \u0434\u0443\u0433\u043e\u0432\u0443\u044e \u043f\u043b\u0430\u0437\u043c\u0443 (\u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442 \u0442\u043e\u043a), \u0437\u0430\u0441\u0442\u0430\u0432\u043b\u044f\u044f \u0434\u0443\u0433\u0443 \u0431\u044b\u0441\u0442\u0440\u043e \u0432\u0440\u0430\u0449\u0430\u0442\u044c\u0441\u044f \u043f\u043e \u043a\u0440\u0443\u0433\u0443 \u0432 \u0441\u0442\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u0433\u0430\u0437\u0435 SF6.<\/li>\n\n\n\n<li><strong>\u041e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u0435:<\/strong> \u041e\u043d \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442 \u043a\u0430\u043a \u201c\u043c\u0435\u0448\u0430\u043b\u043a\u0430\u201d, \u0437\u0430\u0441\u0442\u0430\u0432\u043b\u044f\u044f \u0434\u0443\u0433\u0443 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0430\u0442\u044c\u0441\u044f \u0432 \u0441\u0432\u0435\u0436\u0438\u0439, \u0445\u043e\u043b\u043e\u0434\u043d\u044b\u0439 \u0433\u0430\u0437. \u0427\u0435\u043c \u0432\u044b\u0448\u0435 \u0442\u043e\u043a \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u0442\u0435\u043c \u0431\u044b\u0441\u0442\u0440\u0435\u0435 \u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 \u0435\u0433\u043e \u0441\u0430\u043c\u043e\u0430\u0434\u0430\u043f\u0442\u0438\u0432\u043d\u044b\u043c \u043c\u0435\u0442\u043e\u0434\u043e\u043c \u0433\u0430\u0448\u0435\u043d\u0438\u044f.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-the-three-position-standard-on-off-earth\">6. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0441 \u0442\u0440\u0435\u043c\u044f \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u043c\u0438: \u0412\u041a\u041b \u2013 \u0412\u042b\u041a\u041b \u2013 \u0417\u0410\u0417\u0415\u041c\u041b\u0415\u041d\u0418\u0415<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"2560\" height=\"1396\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-scaled.webp\" alt=\"\u0412\u0438\u0437\u0443\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u044f \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u0430 \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438 \u0432 \u0433\u0430\u0437\u0435 SF6.\" class=\"wp-image-2132\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-scaled.webp 2560w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-1024x559.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-1536x838.webp 1536w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-2048x1117.webp 2048w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-18x10.webp 18w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n\n\n\n<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (IEC 62271-200) \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u043f\u0440\u0435\u0434\u043f\u0438\u0441\u044b\u0432\u0430\u044e\u0442 <strong>\u0422\u0440\u0435\u0445\u043f\u043e\u0437\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0439 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c<\/strong> \u0432 \u0433\u0430\u0437\u043e\u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445. \u042d\u0442\u043e \u0437\u0430\u043c\u0435\u043d\u044f\u0435\u0442 \u0441\u0442\u0430\u0440\u044b\u0439 \u043f\u043e\u0434\u0445\u043e\u0434, \u043f\u0440\u0438 \u043a\u043e\u0442\u043e\u0440\u043e\u043c \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043b\u0438\u0441\u044c \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438, \u0447\u0442\u043e \u0432 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0441\u0442\u0435\u043f\u0435\u043d\u0438 \u0437\u0430\u0432\u0438\u0441\u0435\u043b\u043e \u043e\u0442 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u043a\u043b\u044e\u0447\u0435\u0432\u044b\u0445 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043e\u043a \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043e\u0448\u0438\u0431\u043e\u043a.<\/p>\n\n\n\n<p>\u0422\u0440\u0438 \u043f\u043e\u0437\u0438\u0446\u0438\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u044b \u0432 \u043e\u0434\u0438\u043d \u0432\u0430\u043b \u0438\u043b\u0438 \u0432\u0437\u0430\u0438\u043c\u043e\u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0439 \u0443\u0437\u0435\u043b:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0417\u0430\u043a\u0440\u044b\u0442\u043e (\u0412\u041a\u041b):<\/strong> \u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0446\u0435\u043f\u044c \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0430.<\/li>\n\n\n\n<li><strong>\u041e\u0442\u043a\u0440\u044b\u0442\u043e (\u0412\u042b\u041a\u041b):<\/strong> \u0426\u0435\u043f\u044c \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0430, \u0441 \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u043c \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435\u043c \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438.<\/li>\n\n\n\n<li><strong>\u0417\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435 (EARTH):<\/strong> \u041a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0437\u0430\u043a\u043e\u0440\u043e\u0447\u0435\u043d\u044b \u043d\u0430 \u0437\u0435\u043c\u043b\u044e.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-engineering-advantage\">\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0438\u0438<\/h3>\n\n\n\n<p>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0434\u0435\u043b\u0430\u0435\u0442 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u043c \u043f\u0435\u0440\u0435\u0445\u043e\u0434 \u043e\u0442 <strong>\u0412\u041a\u041b\u042e\u0427\u0415\u041d\u041e<\/strong> \u043d\u0435\u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u0432 <strong>\u0417\u0415\u041c\u041b\u042f<\/strong>. \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u043e\u0439\u0442\u0438 \u0447\u0435\u0440\u0435\u0437 <strong>\u0412\u042b\u041a\u041b<\/strong>. \u042d\u0442\u0430 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u044f\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0441\u0446\u0435\u043d\u0430\u0440\u0438\u0439 \u201c\u0447\u0435\u043b\u043e\u0432\u0435\u0447\u0435\u0441\u043a\u043e\u0439 \u043e\u0448\u0438\u0431\u043a\u0438\u201d \u043f\u0440\u0438 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0438 \u043b\u0438\u043d\u0438\u0438 \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0445 \u043f\u0440\u0438\u0447\u0438\u043d \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0442\u0440\u0430\u0432\u043c \u0432 \u0441\u0442\u0430\u0440\u044b\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0421\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0439 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442:<\/strong> \u041f\u043e\u0434\u0440\u043e\u0431\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u043e \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0441\u043c. \u0432 \u043d\u0430\u0448\u0435\u043c <a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/earthing-switch\/\"><strong>\u041a\u043e\u043c\u043d\u0430\u0442\u043d\u044b\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u0437\u0430\u0437\u0435\u043c\u043b\u044f\u044e\u0449\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 (\u0441\u0435\u0440\u0438\u044f JN15)<\/strong><\/a> \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0447\u0430\u0441\u0442\u043e \u0432\u0441\u0442\u0440\u0430\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0432 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0435 \u0432\u0435\u0440\u0441\u0438\u0438 \u044d\u0442\u0438\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-switch-fuse-coordination-the-striker-mechanism\">7. \u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0438 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f: \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u201cStriker\u201d<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism.webp\" alt=\"\u0418\u043b\u043b\u044e\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u0443\u0434\u0430\u0440\u043d\u043e\u0433\u043e \u0448\u0442\u0438\u0444\u0442\u0430 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f HRC, \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0449\u0435\u0433\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.\" class=\"wp-image-2133\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u041e\u0434\u043d\u0438\u043c \u0438\u0437 \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0438\u043d\u0442\u0435\u0440\u0435\u0441\u043d\u044b\u0445 \u0441 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0442\u043e\u0447\u043a\u0438 \u0437\u0440\u0435\u043d\u0438\u044f \u0430\u0441\u043f\u0435\u043a\u0442\u043e\u0432 LBS \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0442\u043e, \u043a\u0430\u043a \u043e\u043d \u0438\u043c\u0438\u0442\u0438\u0440\u0443\u0435\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432 \u0441\u043e\u0447\u0435\u0442\u0430\u043d\u0438\u0438 \u0441 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f\u043c\u0438. \u042d\u0442\u043e \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u0442\u0441\u044f <strong>\u041c\u042d\u041a 62271-105<\/strong>.<\/p>\n\n\n\n<p>\u0412 \u201c\u043a\u043e\u043c\u0431\u0438\u043d\u0430\u0446\u0438\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0438 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f\u201d \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c LBS \u043d\u0435 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0438\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0440\u0443\u0447\u043d\u044b\u043c; \u043e\u043d \u043e\u0441\u043d\u0430\u0449\u0435\u043d \u043f\u0440\u0443\u0436\u0438\u043d\u043e\u0439 \u0441 \u043d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u043d\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0435\u0439, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043c\u043e\u0436\u0435\u0442 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0442\u044c \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e.<\/p>\n\n\n\n<p><strong>\u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0439:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0441\u0431\u043e\u0439:<\/strong> \u0412 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435.<\/li>\n\n\n\n<li><strong>\u041f\u0435\u0440\u0435\u0433\u043e\u0440\u0430\u043d\u0438\u0435 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f:<\/strong> \u0421\u0438\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043f\u043b\u0430\u0432\u0438\u0442 \u0441\u0435\u0440\u0435\u0431\u0440\u044f\u043d\u044b\u0439 \u044d\u043b\u0435\u043c\u0435\u043d\u0442 \u0432\u043d\u0443\u0442\u0440\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f.<\/li>\n\n\n\n<li><strong>\u0412\u044b\u0442\u0430\u043b\u043a\u0438\u0432\u0430\u043d\u0438\u0435 \u0448\u0442\u0438\u0444\u0442\u0430 \u0443\u0434\u0430\u0440\u043d\u0438\u043a\u0430:<\/strong> \u041a\u043e\u0433\u0434\u0430 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u0442, \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u0437\u0430\u0440\u044f\u0434 \u043f\u043e\u0440\u043e\u0445\u0430 \u0438\u043b\u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u0430 \u0432\u043d\u0443\u0442\u0440\u0438 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f \u0441 \u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u0441\u0438\u043b\u043e\u0439 (\u043f\u0440\u0438\u043c\u0435\u0440\u043d\u043e 60\u2013100 \u041d) \u0432\u044b\u0431\u0440\u0430\u0441\u044b\u0432\u0430\u0435\u0442 \u201c\u0443\u0434\u0430\u0440\u043d\u044b\u0439 \u0448\u0442\u0438\u0444\u0442\u201d \u0438\u0437 \u043a\u043e\u043b\u043f\u0430\u0447\u043a\u0430 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f.<\/li>\n\n\n\n<li><strong>\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u043b\u0430\u043d\u043a\u0430:<\/strong> \u042d\u0442\u043e\u0442 \u0448\u0442\u0438\u0444\u0442 \u0443\u0434\u0430\u0440\u044f\u0435\u0442 \u043f\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u043f\u043b\u0430\u043d\u043a\u0435, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u043e\u0439 \u0441 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u043c LBS.<\/li>\n\n\n\n<li><strong>3-\u0444\u0430\u0437\u043d\u044b\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435:<\/strong> \u041e\u0442\u043a\u0440\u044b\u0442\u0438\u0435 LBS <strong>\u0432\u0441\u0435 \u0442\u0440\u0438 \u0444\u0430\u0437\u044b<\/strong> \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u041f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0442\u0430\u043a \u0432\u0430\u0436\u043d\u043e?<\/strong> \u0415\u0441\u043b\u0438 \u0431\u044b \u043f\u0435\u0440\u0435\u0433\u043e\u0440\u0435\u043b \u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0434\u0438\u043d \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c, \u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043e\u0441\u0442\u0430\u043b\u0441\u044f \u0431\u044b \u0437\u0430\u043c\u043a\u043d\u0443\u0442\u044b\u043c, \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044c \u0438\u043b\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0440\u0430\u0431\u043e\u0442\u0430\u043b\u0438 \u0431\u044b \u043d\u0430 \u0434\u0432\u0443\u0445 \u0444\u0430\u0437\u0430\u0445 (\u201c\u043e\u0434\u043d\u043e\u0444\u0430\u0437\u043d\u044b\u0439 \u0440\u0435\u0436\u0438\u043c\u201d), \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u0435\u043b\u043e \u0431\u044b \u043a \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432\u0443 \u0438 \u0432\u044b\u0445\u043e\u0434\u0443 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f. \u0421\u0432\u044f\u0437\u044c \u0443\u0434\u0430\u0440\u043d\u0438\u043a\u0430 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043f\u043e\u043b\u043d\u0443\u044e \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e \u0432 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"8-lbs-vs-vcb-a-decision-matrix\">8. LBS \u043f\u0440\u043e\u0442\u0438\u0432 VCB: \u043c\u0430\u0442\u0440\u0438\u0446\u0430 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u044f \u0440\u0435\u0448\u0435\u043d\u0438\u0439<\/h2>\n\n\n\n<p>\u0414\u043b\u044f <a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-manufacturer\/\"><strong>\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439<\/strong><\/a>, VCB \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0444\u043b\u0430\u0433\u043c\u0430\u043d\u0441\u043a\u0438\u043c \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u043c. \u041d\u043e \u0434\u043b\u044f \u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0449\u0438\u043a\u0430 \u044d\u0442\u043e \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442 \u0434\u043b\u044f \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u043e\u0439 \u0437\u0430\u0434\u0430\u0447\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th><th>SF6-\u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (LBS)<\/th><th>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB)<\/th><\/tr><tr><td><strong>\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u044f<\/strong><\/td><td>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/td><td>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0438 \u0437\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/td><\/tr><tr><td><strong>\u0423\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/strong><\/td><td><strong>\u041d\u0435\u0442<\/strong> (\u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 HRC)<\/td><td><strong>\u0414\u0430<\/strong> (\u0414\u043e 40 \u043a\u0410+)<\/td><\/tr><tr><td><strong>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0436\u0438\u0437\u043d\u0438<\/strong><\/td><td>\u0423\u043c\u0435\u0440\u0435\u043d\u043d\u0430\u044f (\u043a\u043b\u0430\u0441\u0441 E3 \u043f\u043e IEC, ~100 \u0446\u0438\u043a\u043b\u043e\u0432 \u043f\u0440\u0438 \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435)<\/td><td>\u0412\u044b\u0441\u043e\u043a\u0430\u044f (\u043a\u043b\u0430\u0441\u0441 E2\/C2 \u043f\u043e \u041c\u042d\u041a, ~10 000 \u0446\u0438\u043a\u043b\u043e\u0432 \u043f\u0440\u0438 \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435)<\/td><\/tr><tr><td><strong>\u0421\u043b\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/strong><\/td><td>\u041f\u0440\u043e\u0441\u0442\u043e\u0439 (\u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c)<\/td><td>\u041a\u043e\u043c\u043f\u043b\u0435\u043a\u0441 (\u0440\u0435\u043b\u0435, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0442\u043e\u043a\u0430, \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u0435)<\/td><\/tr><tr><td><strong>\u0411\u0430\u0437\u0430 \u0440\u0430\u0441\u0447\u0435\u0442\u0430 \u0437\u0430\u0442\u0440\u0430\u0442<\/strong><\/td><td>\u041d\u0438\u0437\u043a\u0430\u044f (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c)<\/td><td>\u0412\u044b\u0441\u043e\u043a\u0430\u044f (\u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0432 3\u20134 \u0440\u0430\u0437\u0430 \u0432\u044b\u0448\u0435 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 LBS)<\/td><\/tr><tr><td><strong>\u0422\u0438\u043f\u0438\u0447\u043d\u0430\u044f \u0440\u043e\u043b\u044c<\/strong><\/td><td>\u041a\u043e\u043b\u044c\u0446\u0435\u0432\u044b\u0435 \u043a\u0430\u0431\u0435\u043b\u0438 RMU, \u0440\u0443\u0447\u043d\u043e\u0435 \u0441\u0435\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435<\/td><td>\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u0438, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0435 \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u044b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"9-strategic-applications-environmental-future\">9. \u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0438 \u0431\u0443\u0434\u0443\u0449\u0435\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"current-applications\">\u0422\u0435\u043a\u0443\u0449\u0438\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041a\u043b\u0430\u0441\u0442\u0435\u0440\u044b \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438:<\/strong> \u0412 \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u0442\u043e\u043f\u043e\u043b\u043e\u0433\u0438\u044f \u201c\u0446\u0435\u043f\u043e\u0447\u043a\u0438\u201d \u0441\u043e\u0435\u0434\u0438\u043d\u044f\u0435\u0442 \u0442\u0443\u0440\u0431\u0438\u043d\u044b \u0432 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0431\u043b\u043e\u043a\u043e\u0432 LBS, \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u043d\u044b\u0445 \u0443 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u0430\u0436\u0434\u043e\u0439 \u0431\u0430\u0448\u043d\u0438.<\/li>\n\n\n\n<li><strong>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0435 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0435 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438 (CSS):<\/strong> \u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430 \u0441 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u043e\u0439 \u043a\u0440\u044b\u0448\u043a\u043e\u0439 \u043d\u0435 \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u0435\u0442 \u0432\u043b\u0430\u0433\u0443 \u0438 \u043f\u044b\u043b\u044c, \u0447\u0442\u043e \u0434\u0435\u043b\u0430\u0435\u0442 SF6 LBS \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u043c \u0434\u043b\u044f \u0441\u0431\u043e\u0440\u043d\u044b\u0445 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0439, \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u043c\u044b\u0445 \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435.<\/li>\n\n\n\n<li><strong>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u0446\u0438\u043a\u043b\u043e\u0432:<\/strong> \u041c\u043e\u0442\u043e\u0440\u0438\u0437\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 LBS \u0432 \u0441\u043e\u0447\u0435\u0442\u0430\u043d\u0438\u0438 \u0441 RTU \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u0442\u044c \u201c\u0441\u0430\u043c\u043e\u0432\u043e\u0441\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u044e\u0449\u0438\u0435\u0441\u044f \u0441\u0435\u0442\u0438\u201d, \u0432 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0438\u0437\u043e\u043b\u0438\u0440\u0443\u044e\u0442\u0441\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0437\u0430 \u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u0435 \u0441\u0435\u043a\u0443\u043d\u0434\u044b.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-environmental-challenge-f-gas-regulations\">\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 (\u043f\u0440\u0430\u0432\u0438\u043b\u0430 \u043f\u043e \u0444\u0442\u043e\u0440\u0441\u043e\u0434\u0435\u0440\u0436\u0430\u0449\u0438\u043c \u0433\u0430\u0437\u0430\u043c)<\/h3>\n\n\n\n<p>SF6 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043c\u043e\u0449\u043d\u044b\u043c \u043f\u0430\u0440\u043d\u0438\u043a\u043e\u0432\u044b\u043c \u0433\u0430\u0437\u043e\u043c (GWP 23 500). \u041d\u043e\u0432\u044b\u0435 \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u044b\u0435 \u0430\u043a\u0442\u044b (\u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u0420\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442 \u0415\u0421 \u043f\u043e \u0444\u0442\u043e\u0440\u0441\u043e\u0434\u0435\u0440\u0436\u0430\u0449\u0438\u043c \u0433\u0430\u0437\u0430\u043c) \u0441\u043f\u043e\u0441\u043e\u0431\u0441\u0442\u0432\u0443\u044e\u0442 \u043f\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e\u043c\u0443 \u043e\u0442\u043a\u0430\u0437\u0443 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f SF6 \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. <strong>\u0410\u043b\u044c\u0442\u0435\u0440\u043d\u0430\u0442\u0438\u0432\u044b:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 LBS:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0443\u044e \u0431\u0443\u0442\u044b\u043b\u043a\u0443 \u0434\u043b\u044f \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438 (\u043a\u0430\u043a VCB), \u043d\u043e \u0441 \u0431\u043e\u043b\u0435\u0435 \u043f\u0440\u043e\u0441\u0442\u044b\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u043c.<\/li>\n\n\n\n<li><strong>\u0427\u0438\u0441\u0442\u044b\u0439 \u0432\u043e\u0437\u0434\u0443\u0445 \/ \u0421\u0443\u0445\u043e\u0439 \u0432\u043e\u0437\u0434\u0443\u0445:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0441\u0443\u0445\u043e\u0439 \u0441\u0436\u0430\u0442\u044b\u0439 \u0432\u043e\u0437\u0434\u0443\u0445 \u0434\u043b\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438, \u0447\u0442\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043d\u0435\u043c\u043d\u043e\u0433\u043e \u0431\u043e\u043b\u0435\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u0445 \u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u043e\u0432 \u0438\u043b\u0438 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f.<\/li>\n\n\n\n<li><strong>\u0422\u0432\u0435\u0440\u0434\u044b\u0439 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u043a:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u0443\u044e \u0441\u043c\u043e\u043b\u0443 \u0434\u043b\u044f \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f, \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u044f \u0433\u0430\u0437.<\/li>\n<\/ol>\n\n\n\n<p>\u0412 \u043f\u0435\u0440\u0438\u043e\u0434 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u0430 \u043e\u0442\u0440\u0430\u0441\u043b\u0438 SF6 \u043f\u043e-\u043f\u0440\u0435\u0436\u043d\u0435\u043c\u0443 \u0434\u043e\u043c\u0438\u043d\u0438\u0440\u0443\u0435\u0442 \u0432 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0439 \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0435 \u0438 \u043d\u0430 \u0440\u044b\u043d\u043a\u0430\u0445, \u0433\u0434\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u043c \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"10-engineer-s-faq\">10. \u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0430<\/h2>\n\n\n\n<p><strong>\u04121: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c SF6 LBS \u043f\u0440\u0438 \u043d\u0438\u0437\u043a\u043e\u043c \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0438 \u0433\u0430\u0437\u0430?<\/strong> <strong>\u0421\u0442\u0440\u043e\u0433\u043e \u043d\u0435\u0442.<\/strong> \u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0433\u0430\u0441\u0438\u0442\u044c \u0434\u0443\u0433\u0443 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u0438 \u0433\u0430\u0437\u0430. \u0415\u0441\u043b\u0438 \u043c\u0430\u043d\u043e\u043c\u0435\u0442\u0440 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0438\u0437\u043a\u043e\u0435 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0435 (\u043e\u0431\u044b\u0447\u043d\u043e \u043a\u0440\u0430\u0441\u043d\u0430\u044f \u0437\u043e\u043d\u0430), \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0440\u0430\u0431\u043e\u0442\u0443. \u041f\u0440\u0438\u043d\u0443\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u0432 \u0442\u0430\u043a\u043e\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044e \u0438 \u0440\u0430\u0437\u0440\u044b\u0432\u0443 \u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u0443\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443 SF6 LBS?<\/strong> \u0412 \u043e\u0442\u043b\u0438\u0447\u0438\u0435 \u043e\u0442 VCB, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0431\u043b\u043e\u043a\u0430 \u043d\u0435 \u0442\u0430\u043a \u043b\u0435\u0433\u043a\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c. \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0432 \u0441\u0435\u0431\u044f:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0433\u0430\u0437\u0430:<\/strong> \u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440 \u043c\u0430\u043d\u043e\u043c\u0435\u0442\u0440\u0430.<\/li>\n\n\n\n<li><strong>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 (\u0442\u0435\u0441\u0442 \u0414\u0443\u043a\u0442\u043e\u0440\u0430):<\/strong> \u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u0432\u0442\u0443\u043b\u043a\u0430\u043c\u0438 (\u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f &lt; 50 \u043c\u043a\u041e\u043c).<\/li>\n\n\n\n<li><strong>\u0427\u0430\u0441\u0442\u0438\u0447\u043d\u044b\u0439 \u0440\u0430\u0437\u0440\u044f\u0434 (\u0427\u0420):<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0440\u0443\u0447\u043d\u044b\u0435 \u0434\u0430\u0442\u0447\u0438\u043a\u0438 TEV\/\u0443\u043b\u044c\u0442\u0440\u0430\u0437\u0432\u0443\u043a\u043e\u0432\u044b\u0435 \u0434\u0430\u0442\u0447\u0438\u043a\u0438 \u0434\u043b\u044f \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0431\u0435\u0437 \u0432\u0441\u043a\u0440\u044b\u0442\u0438\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041c\u043e\u0436\u0435\u0442 \u043b\u0438 LBS \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438?<\/strong> \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 LBS \u043d\u0435 \u0441\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441 \u0435\u043c\u043a\u043e\u0441\u0442\u043d\u044b\u043c\u0438 \u0442\u043e\u043a\u0430\u043c\u0438 (\u043b\u0438\u043d\u0438\u0438 \u0438\u043b\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438) \u0438\u0437-\u0437\u0430 \u0440\u0438\u0441\u043a\u0430 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0437\u0430\u043f\u0443\u0441\u043a\u0430. \u0412\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0443\u043a\u0430\u0437\u0430\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u043f\u0440\u043e\u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u043d\u0430 <strong>IEC 62271-103 \u041a\u043b\u0430\u0441\u0441 C1 \u0438\u043b\u0438 C2<\/strong> \u0435\u0441\u043b\u0438 \u0432\u044b \u043f\u043b\u0430\u043d\u0438\u0440\u0443\u0435\u0442\u0435 \u0447\u0430\u0441\u0442\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u043d\u0435\u0437\u0430\u0433\u0440\u0443\u0436\u0435\u043d\u043d\u044b\u0435 \u043a\u0430\u0431\u0435\u043b\u0438 \u0438\u043b\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"11-conclusion-specifying-for-the-right-application\">11. \u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435: \u0432\u044b\u0431\u043e\u0440 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<p>The <strong>\u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 SF6<\/strong> \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u043e\u0441\u043d\u043e\u0432\u043e\u0439 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043d\u0435 \u043f\u043e\u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u044d\u0442\u043e \u0441\u0430\u043c\u043e\u0435 \u043c\u043e\u0449\u043d\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e, \u0430 \u043f\u043e\u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u043e\u043d\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u043c. \u041e\u043d\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0431\u0430\u043b\u0430\u043d\u0441 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438, \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u043f\u043e\u0434\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0433\u043e \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u0430 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0443\u0437\u043b\u043e\u0432 \u0432 \u0441\u0435\u0442\u0438.<\/p>\n\n\n\n<p>\u0423\u0441\u043f\u0435\u0448\u043d\u043e\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 VCB \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 LBS \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0442\u043e\u043a\u043e\u043c. \u0421\u043c\u0435\u0448\u0435\u043d\u0438\u0435 \u044d\u0442\u0438\u0445 \u0434\u0432\u0443\u0445 \u043f\u043e\u043d\u044f\u0442\u0438\u0439 \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0440\u0430\u0437\u0434\u0443\u0442\u043e\u043c\u0443 \u0431\u044e\u0434\u0436\u0435\u0442\u0443 \u0438\u043b\u0438 \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<div class=\"xbrele-classic-card\">\n    <div class=\"card-inner\">\n        <div class=\"card-thumb\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/download-icon.webp\" alt=\"\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 PDF-\u0444\u0430\u0439\u043b \u043e \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u0442\u0435\u043b\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 SF6\">\n        <\/div>\n        \n        <div class=\"card-details\">\n            <span class=\"card-label\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442<\/span>\n            <h3>\u0420\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u0438 \u043d\u0430 SF6: \u043f\u0440\u0438\u043d\u0446\u0438\u043f \u0440\u0430\u0431\u043e\u0442\u044b \u0438 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 LBS \u0438 VCB<\/h3>\n            <p>\u041f\u043e\u0434\u0440\u043e\u0431\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e, \u0432 \u043a\u043e\u0442\u043e\u0440\u043e\u043c \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430 \u0433\u0430\u0437\u0430 SF6, \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u044b \u0433\u0430\u0448\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u0438 \u0438 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u0441\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 LBS \u0438 VCB \u0434\u043b\u044f \u0441\u0435\u0442\u0435\u0439 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n            \n            <div class=\"card-meta\">\n                <span><i class=\"far fa-file-pdf\"><\/i> **\u0424\u043e\u0440\u043c\u0430\u0442:** \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442 PDF<\/span>\n                <span><i class=\"far fa-user\"><\/i> **\u0410\u0432\u0442\u043e\u0440:** \u0425\u0430\u043d\u043d\u0430 \u0427\u0436\u0443<\/span>\n            <\/div>\n            \n            <a href=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele.com-What-Is-an-SF6-Load-Break-Switch-Working-Principle-LBS-vs-VCB-Guide.pdf\" class=\"card-download-btn\" target=\"_blank\" rel=\"noopener\">\n                <i class=\"fas fa-file-download\"><\/i> \u0421\u043a\u0430\u0447\u0430\u0442\u044c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e SF6 LBS\n            <\/a>\n        <\/div>\n    <\/div>\n<\/div>\n\n<style>\n\/* XBRELE \u7ecf\u5178\u5de5\u4e1a\u98ce\u683c - \u54c1\u724c\u8272 #0fb4ad *\/\n.xbrele-classic-card {\n    background: #fdfdfd;\n    border: 1px solid #e1e4e8;\n    border-left: 6px solid #0fb4ad; \/* \u54c1\u724c\u9752\u7eff\u8272\u4fa7\u8fb9\u6761 *\/\n    padding: 28px;\n    margin: 35px 0;\n    border-radius: 4px;\n    box-shadow: 0 2px 12px rgba(0,0,0,0.04);\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n}\n\n.card-inner {\n    display: flex;\n    gap: 30px;\n    align-items: center;\n}\n\n.card-thumb img {\n    width: 130px; \n    height: auto;\n    border-radius: 2px;\n}\n\n.card-label {\n    color: #0fb4ad;\n    font-size: 12px;\n    text-transform: uppercase;\n    font-weight: 800;\n    letter-spacing: 1.2px;\n    margin-bottom: 6px;\n    display: block;\n}\n\n.card-details h3 {\n    margin: 5px 0 10px 0;\n    font-size: 22px;\n    color: #1a1a1a;\n    line-height: 1.3;\n}\n\n.card-details p {\n    font-size: 14.5px;\n    color: #586069;\n    margin-bottom: 18px;\n    line-height: 1.5;\n}\n\n.card-meta {\n    font-size: 13px;\n    color: #959da5;\n    margin-bottom: 22px;\n    display: flex;\n    gap: 20px;\n}\n\n.card-meta i {\n    color: #0fb4ad;\n    margin-right: 5px;\n}\n\n.card-download-btn {\n    display: inline-flex;\n    align-items: center;\n    gap: 10px;\n    background-color: #0fb4ad;\n    color: #ffffff !important;\n    padding: 12px 28px;\n    border-radius: 3px;\n    text-decoration: none !important;\n    font-weight: 700;\n    font-size: 15px;\n    transition: all 0.25s ease;\n    box-shadow: 0 4px 10px rgba(15, 180, 173, 0.2);\n}\n\n.card-download-btn:hover {\n    background-color: #0d9b94;\n    box-shadow: 0 6px 15px rgba(15, 180, 173, 0.3);\n    transform: translateY(-1px);\n}\n\n\/* \u54cd\u5e94\u5f0f\u9002\u914d\u79fb\u52a8\u7aef *\/\n@media (max-width: 650px) {\n    .card-inner { flex-direction: column; text-align: center; }\n    .card-thumb img { width: 100px; }\n    .card-meta { justify-content: center; }\n}\n<\/style>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0420\u0435\u0441\u0443\u0440\u0441\u044b \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u0431\u043e\u0440\u0430<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ru\/products\/\">\u043e\u0431\u0437\u043e\u0440 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/a> \u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0438 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u044f \u043f\u043e \u0432\u0432\u043e\u0434\u0443 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Engineering Key Takeaways \ud83d\udd39 LBS vs. VCB Distinction: An LBS is designed for load management (switching nominal currents), whereas a VCB is a protection device for interrupting massive fault currents. \ud83d\udd39 The 3-Position Safety Logic: Modern RMUs use a mechanically interlocked sequence (ON \u2192 OFF \u2192 EARTH) to physically prevent human errors, such as earthing [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2129,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27,24],"tags":[],"class_list":["post-2126","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2126"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2126\/revisions"}],"predecessor-version":[{"id":3649,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2126\/revisions\/3649"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2129"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}