{"id":2238,"date":"2025-12-20T12:02:09","date_gmt":"2025-12-20T12:02:09","guid":{"rendered":"https:\/\/xbrele.com\/?p=2238"},"modified":"2026-05-25T14:29:01","modified_gmt":"2026-05-25T14:29:01","slug":"3-phase-transformer-technical-guide","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/3-phase-transformer-technical-guide\/","title":{"rendered":"\u041f\u043e\u043b\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c: \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0435 \u0433\u0440\u0443\u043f\u043f\u044b \u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432 \u0441\u0435\u0442\u044c"},"content":{"rendered":"<p><strong>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c:<\/strong> \u041e\u0442 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u0434\u043e \u043f\u0440\u043e\u0434\u0432\u0438\u043d\u0443\u0442\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f<\/p>\n\n\n\n\u041f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u044b\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b: <a href=\"https:\/\/webstore.iec.ch\/publication\/599\" target=\"_blank\" rel=\"noopener\">\u041c\u042d\u041a 60076<\/a>, <a href=\"https:\/\/standards.ieee.org\/standard\/C57_12_00-2021.html\" target=\"_blank\" rel=\"noopener\">IEEE C57.12.00<\/a>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u041e\u0441\u0432\u043e\u0435\u043d\u0438\u0435 \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432: \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0435 \u0433\u0440\u0443\u043f\u043f\u044b, \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432 \u0441\u0435\u0442\u044c | XBRELE\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/V3tc-ZrtfFE?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-introduction-the-strategic-role-of-transformers-in-modern-grids\">1. \u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435: \u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0440\u043e\u043b\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0432 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445<\/h2>\n\n\n\n<p>\u0412 \u0438\u0435\u0440\u0430\u0440\u0445\u0438\u0438 \u0430\u043a\u0442\u0438\u0432\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u0430\u0436\u043d\u044b\u043c \u0443\u0437\u043b\u043e\u043c. \u041f\u043e\u043c\u0438\u043c\u043e \u043f\u0440\u043e\u0441\u0442\u043e\u0433\u043e \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043e\u043d \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u0435\u0442 \u043a\u0430\u043a \u0444\u0438\u043b\u044c\u0442\u0440 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a, \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442 \u0434\u043b\u044f \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u0439 \u0431\u0430\u0440\u044c\u0435\u0440 \u043f\u0440\u043e\u0442\u0438\u0432 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<div style=\"background-color: #f0faf9; border-left: 4px solid #0fb4ad; padding: 20px; margin: 25px 0;\"> <strong style=\"color: #0fb4ad; font-size: 1.1em;\">\u0418\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u044b\u0435 \u0437\u043d\u0430\u043d\u0438\u044f:<\/strong> \u041f\u043e \u043c\u0435\u0440\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u0430 \u043e\u0442\u0440\u0430\u0441\u043b\u0438 \u043a <strong>\u0418\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u0441\u0435\u0442\u0438<\/strong> \u0438 <strong>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/strong>, \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0438 \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u0430\u044f \u0433\u0440\u0443\u043f\u043f\u0430, \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 <a href=\"https:\/\/xbrele.com\/ru\/what-is-vacuum-circuit-breaker-working-principle\/\" style=\"color: #0fb4ad; text-decoration: underline;\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 (VCB)<\/a> \u0438 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b. <\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-quick-takeaways-core-engineering-summary\">2. \u041a\u0440\u0430\u0442\u043a\u043e\u0435 \u0440\u0435\u0437\u044e\u043c\u0435: \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<div style=\"background-color: #ffffff; border: 1px solid #0fb4ad; padding: 20px; margin: 25px 0; border-radius: 8px;\"> <ul style=\"line-height: 1.6; color: #333; margin: 0; padding-left: 20px;\"> <li><strong>\u041e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 <strong>\u041a\u0420\u0413\u041e \u043a\u0440\u0435\u043c\u043d\u0438\u0435\u0432\u0430\u044f \u0441\u0442\u0430\u043b\u044c<\/strong> \u0441 \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c\u044e \u043f\u043e\u0442\u043e\u043a\u0430 (<i>B<\/i>) \u043e\u0442 1,5 \u0422 \u0434\u043e 1,7 \u0422 \u0434\u043b\u044f \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u0442\u0435\u0440\u044c \u0436\u0435\u043b\u0435\u0437\u0430.<\/li> <li><strong>\u041f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u0430\u044f \u0433\u0440\u0443\u043f\u043f\u0430:<\/strong> <strong>Dyn11<\/strong> \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043c\u0438\u0440\u043e\u0432\u044b\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u043c \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0441\u0432\u043e\u0435\u0439 \u043d\u0435\u0439\u0442\u0440\u0430\u043b\u044c\u043d\u043e\u0439 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0438 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043f\u043e\u0433\u043b\u043e\u0449\u0435\u043d\u0438\u044e.<\/li> <li><strong>\u041f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430:<\/strong> \u041d\u0435\u043f\u043e\u0434\u043b\u0435\u0436\u0430\u0449\u0438\u0435 \u043e\u0431\u0441\u0443\u0436\u0434\u0435\u043d\u0438\u044e \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432 \u0441\u0435\u0431\u044f \u0438\u0434\u0435\u043d\u0442\u0438\u0447\u043d\u044b\u0435 <strong>\u041a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u044b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>, \u0438\u0434\u0435\u043d\u0442\u0438\u0447\u043d\u044b\u0439 <strong>\u0412\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0435 \u0433\u0440\u0443\u043f\u043f\u044b<\/strong>, \u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u043b\u043e <strong>%Z<\/strong> (\u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u00b110%).<\/li> <li><strong>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f:<\/strong> \u0420\u0435\u0430\u043b\u0438\u0437\u043e\u0432\u0430\u0442\u044c <a href=\"https:\/\/xbrele.com\/ru\/transformer-oil-technical-guide\/\" style=\"color: #0fb4ad; text-decoration: underline;\">DGA (\u0430\u043d\u0430\u043b\u0438\u0437 \u0440\u0430\u0441\u0442\u0432\u043e\u0440\u0435\u043d\u043d\u043e\u0433\u043e \u0433\u0430\u0437\u0430)<\/a> \u0434\u043b\u044f \u043d\u0435\u0444\u0442\u044f\u043d\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a \u0438 <strong>PT100<\/strong> \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u043a\u0430 \u0434\u043b\u044f \u0441\u0443\u0445\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441 \u0446\u0435\u043b\u044c\u044e \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0433\u043e\u043d\u0430.<\/li> <li><strong>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b:<\/strong> \u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e VCB \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u044b \u043d\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 (\u0434\u043e 12\u00d7 <i>I<sub>n<\/sub><\/i>), \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439.<\/li> <\/ul> <\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-advanced-working-principles-the-magnetic-circuit\">3. \u0420\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u044b \u0440\u0430\u0431\u043e\u0442\u044b: \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0443\u0440<\/h2>\n\n\n\n<p>\u0422\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u043d\u044b\u0439 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0443\u0440, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u0435 \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430 \u0441\u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"3-1-the-120-phase-displacement-and-flux-balance\">3.1 \u0421\u0434\u0432\u0438\u0433 \u0444\u0430\u0437\u044b \u043d\u0430 120\u00b0 \u0438 \u0431\u0430\u043b\u0430\u043d\u0441 \u043f\u043e\u0442\u043e\u043a\u0430<\/h4>\n\n\n\n<p>\u0412 \u0441\u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 \u0441\u0443\u043c\u043c\u0430 \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u044b\u0445 \u043f\u043e\u0442\u043e\u043a\u043e\u0432 \u0432 \u043b\u044e\u0431\u043e\u0439 \u043c\u043e\u043c\u0435\u043d\u0442 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0440\u0430\u0432\u043d\u0430 \u043d\u0443\u043b\u044e:<\/p> <p style=\"text-align: center; font-family: 'Courier New', Courier, monospace; font-size: 1.3em; background: #ffffff; padding: 15px; border: 1px solid #0fb4ad; color: #333; border-radius: 4px;\"> \u03a6<sub>1<\/sub> + \u03a6<sub>2<\/sub> + \u03a6<sub>3<\/sub> = 0 <\/p>\n\n<p>\u042d\u0442\u043e \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 <strong>3-\u043a\u043e\u043d\u0435\u0447\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f<\/strong>, \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e, \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0445\u043e\u043b\u043e\u0434\u043d\u043e\u043a\u0430\u0442\u0430\u043d\u043e\u0439 \u0437\u0435\u0440\u043d\u0438\u0441\u0442\u043e\u0439 \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 (<strong>CRGO<\/strong>) \u043a\u0440\u0435\u043c\u043d\u0438\u0435\u0432\u043e\u0439 \u0441\u0442\u0430\u043b\u0438. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044f \u0446\u0435\u043d\u0442\u0440\u0430\u043b\u044c\u043d\u044b\u0435 \u0432\u0435\u0442\u0432\u0438 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u043e\u0431\u0440\u0430\u0442\u043d\u044b\u0445 \u043f\u0443\u0442\u0435\u0439 \u0434\u0440\u0443\u0433 \u0434\u043b\u044f \u0434\u0440\u0443\u0433\u0430, \u044d\u0442\u0430 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u0430 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044c \u0432 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430\u0445, \u0442\u0435\u043c \u0441\u0430\u043c\u044b\u043c \u0441\u043d\u0438\u0436\u0430\u044f <strong>\u041f\u043e\u0442\u0435\u0440\u0438 \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (\u043f\u043e\u0442\u0435\u0440\u0438 \u0432 \u0436\u0435\u043b\u0435\u0437\u0435)<\/strong> \u0438 \u043e\u043f\u0442\u0438\u043c\u0438\u0437\u0430\u0446\u0438\u044f \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/flux-displacement-3-phase-transformer-core.webp\" alt=\"\u0421\u0445\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0434\u0438\u0430\u0433\u0440\u0430\u043c\u043c\u0430, \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0449\u0430\u044f \u0444\u0430\u0437\u043e\u0432\u043e\u0435 \u0441\u043c\u0435\u0449\u0435\u043d\u0438\u0435 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0445 \u043f\u043e\u0442\u043e\u043a\u043e\u0432 \u043d\u0430 120 \u0433\u0440\u0430\u0434\u0443\u0441\u043e\u0432 \u0432 \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u043e\u043c \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430, \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0449\u0430\u044f \u0441\u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043f\u043e\u0442\u043e\u043a\u043e\u0432.\" class=\"wp-image-2239\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/flux-displacement-3-phase-transformer-core.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/flux-displacement-3-phase-transformer-core-300x300.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/flux-displacement-3-phase-transformer-core-150x150.webp 150w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/flux-displacement-3-phase-transformer-core-768x768.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/flux-displacement-3-phase-transformer-core-12x12.webp 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"3-2-flux-density-and-saturation-risk\">3.2 \u041f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0442\u043e\u043a\u0430 \u0438 \u0440\u0438\u0441\u043a \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f<\/h4>\n\n\n\n<p>\u0414\u0438\u0437\u0430\u0439\u043d\u0435\u0440\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0442\u0449\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0441\u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 (<i>B<\/i>), \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e, \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u043d\u0430 <strong>1,5 \u0442<\/strong> \u0438 <strong>1,7 \u0422<\/strong>. <strong>\u0427\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u043e\u0437\u0431\u0443\u0436\u0434\u0435\u043d\u0438\u0435<\/strong>, \u0447\u0430\u0441\u0442\u043e \u0432\u044b\u0437\u0432\u0430\u043d\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438\u043b\u0438 \u043d\u0438\u0437\u043a\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u043e\u0439 (\u0430\u043d\u043e\u043c\u0430\u043b\u044c\u043d\u044b\u043c <i>V\/f<\/i> \u0441\u043e\u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435), \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0440\u0438\u0441\u043a\u0430\u043c:<\/p>\n\n<ul style=\"line-height: 1.8; color: #444;\"> <li><strong>\u0412\u0441\u043f\u043b\u0435\u0441\u043a \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430:<\/strong> \u0423\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0430 10% \u0441\u0432\u0435\u0440\u0445 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044e \u0442\u043e\u043a\u0430 \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u043d\u0430 100%.<\/li> <li><strong>\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0435:<\/strong> \u041d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0435 \u044f\u0434\u0440\u0430 \u0433\u0435\u043d\u0435\u0440\u0438\u0440\u0443\u0435\u0442 \u0442\u044f\u0436\u0435\u043b\u044b\u0439 3<sup>rd<\/sup> \u0438 5<sup>th<\/sup> \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438, \u0443\u0445\u0443\u0434\u0448\u0430\u044e\u0449\u0438\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438.<\/li> <li><strong>\u0421\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432:<\/strong> \u041b\u043e\u043a\u0430\u043b\u044c\u043d\u044b\u0439 \u043d\u0430\u0433\u0440\u0435\u0432 \u0432 \u0431\u043e\u043b\u0442\u0430\u0445 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u0438 \u0437\u0430\u0436\u0438\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u0445 \u0438\u0437-\u0437\u0430 \u0443\u0442\u0435\u0447\u043a\u0438 \u0440\u0430\u0441\u0441\u0435\u044f\u043d\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430.<\/li> <\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-efficiency-and-economic-impact-understanding-losses\">4. \u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0438 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435: \u043f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043f\u043e\u0442\u0435\u0440\u044c<\/h2>\n\n\n\n<p>\u041f\u0440\u0438 \u0437\u0430\u043a\u0443\u043f\u043a\u0430\u0445 \u0432 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0435 B2B \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u043b\u0430\u0434\u0435\u043d\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u043c (TOC) \u0437\u0430\u0447\u0430\u0441\u0442\u0443\u044e \u0438\u043c\u0435\u0435\u0442 \u0431\u043e\u043b\u044c\u0448\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435, \u0447\u0435\u043c \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u043a\u0443\u043f\u043d\u0430\u044f \u0446\u0435\u043d\u0430.<\/p>\n\n\n\n<p><strong>\u041e\u0431\u0449\u0438\u0435 \u043f\u043e\u0442\u0435\u0440\u0438 = \u043f\u043e\u0442\u0435\u0440\u0438 \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 + \u043f\u043e\u0442\u0435\u0440\u0438 \u043f\u0440\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435<\/strong><\/p>\n\n<ul> <li><strong>\u041f\u043e\u0442\u0435\u0440\u0438 \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (\u043f\u043e\u0442\u0435\u0440\u0438 \u0432 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435):<\/strong> \u0412\u043e\u0437\u043d\u0438\u043a\u0430\u044e\u0442 \u0438\u0437-\u0437\u0430 \u0433\u0438\u0441\u0442\u0435\u0440\u0435\u0437\u0438\u0441\u0430 \u0438 \u0432\u0438\u0445\u0440\u0435\u0432\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 \u0432 \u0436\u0435\u043b\u0435\u0437\u043d\u043e\u043c \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435. \u041e\u043d\u0438 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u043c\u0438, \u043f\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043d\u0430\u0445\u043e\u0434\u0438\u0442\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c, \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e \u043e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/li> <li><strong>\u041f\u043e\u0442\u0435\u0440\u0438 \u043d\u0430 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435 (\u043f\u043e\u0442\u0435\u0440\u0438 \u0432 \u043c\u0435\u0434\u0438):<\/strong> \u041f\u0440\u043e\u043f\u043e\u0440\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e \u043a\u0432\u0430\u0434\u0440\u0430\u0442\u0443 \u0442\u043e\u043a\u0430 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (<i>I<sup>2<\/sup>R<\/i>). \u041e\u043d\u0438 \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u044e\u0442\u0441\u044f \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u044f.<\/li> <\/ul>\n\n<div style=\"background-color: #f0faf9; border-left: 4px solid #0fb4ad; padding: 15px; margin: 20px 0;\"> <strong style=\"color: #0fb4ad;\">\u0418\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u043e\u0435 \u043f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 <a href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/amorphous-alloy-transformer\/\" style=\"color: #0fb4ad; text-decoration: underline;\">\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0438\u0437 \u0430\u043c\u043e\u0440\u0444\u043d\u043e\u0433\u043e \u0441\u043f\u043b\u0430\u0432\u0430<\/a> \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0437\u0430 \u0441\u0447\u0435\u0442 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u0442\u0435\u0440\u044c \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043e 70% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0438\u0437 \u043a\u0440\u0435\u043c\u043d\u0438\u0435\u0432\u043e\u0439 \u0441\u0442\u0430\u043b\u0438. <\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-efficiency-amorphous-alloy-vs-crgo.webp\" alt=\"\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0433\u0440\u0430\u0444\u0438\u043a, \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0449\u0438\u0439 \u0440\u0430\u0437\u043d\u0438\u0446\u0443 \u0432 \u043f\u043e\u0442\u0435\u0440\u044f\u0445 \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043c\u0435\u0436\u0434\u0443 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0438\u0437 \u043a\u0440\u0435\u043c\u043d\u0438\u0435\u0432\u043e\u0439 \u0441\u0442\u0430\u043b\u0438 CRGO \u0438 \u0443\u0441\u043e\u0432\u0435\u0440\u0448\u0435\u043d\u0441\u0442\u0432\u043e\u0432\u0430\u043d\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0438\u0437 \u0430\u043c\u043e\u0440\u0444\u043d\u043e\u0433\u043e \u0441\u043f\u043b\u0430\u0432\u0430, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u043f\u043e\u0442\u0435\u0440\u0438 \u0434\u043b\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0438\u0445.\" class=\"wp-image-2240\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-efficiency-amorphous-alloy-vs-crgo.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-efficiency-amorphous-alloy-vs-crgo-300x300.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-efficiency-amorphous-alloy-vs-crgo-150x150.webp 150w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-efficiency-amorphous-alloy-vs-crgo-768x768.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/transformer-efficiency-amorphous-alloy-vs-crgo-12x12.webp 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-analysis-of-winding-connections\">5. \u0410\u043d\u0430\u043b\u0438\u0437 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0438<\/h2>\n\n\n\n<p>\u0412\u044b\u0431\u043e\u0440 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u043d\u0443\u043b\u0435\u0432\u043e\u0439 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u0435\u0435 \u0440\u0435\u0430\u043a\u0446\u0438\u044e \u043d\u0430 \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u044b\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u0422\u0438\u043f \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f<\/th><th>\u0421\u0438\u043c\u0432\u043e\u043b IEC<\/th><th>\u0422\u0435\u0440\u043c\u0438\u043d IEEE<\/th><th>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e<\/th><th>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435<\/th><\/tr><tr><td><strong>\u0417\u0432\u0435\u0437\u0434\u0430<\/strong><\/td><td><strong>Y \/ y<\/strong><\/td><td><strong>\u0423\u0430\u0439<\/strong><\/td><td>\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u0430 \u043d\u0435\u0439\u0442\u0440\u0430\u043b\u044c\u043d\u0430\u044f \u0442\u043e\u0447\u043a\u0430; \u0433\u0440\u0430\u0434\u0438\u0435\u043d\u0442\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0437\u0430\u0442\u0440\u0430\u0442\u044b.<\/td><td>\u0423\u044f\u0437\u0432\u0438\u043c \u043a \u043d\u0435\u0441\u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u043c\u0443 \u043f\u043e\u0442\u043e\u043a\u0443 3-\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438.<\/td><\/tr><tr><td><strong>\u0414\u0435\u043b\u044c\u0442\u0430<\/strong><\/td><td><strong>D \/ d<\/strong><\/td><td><strong>\u0414\u0435\u043b\u044c\u0442\u0430<\/strong><\/td><td>\u041b\u043e\u0432\u0438\u0442 3-\u044e \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0443; \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u0442\u044c \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f.<\/td><td>\u0411\u0435\u0437 \u043d\u0435\u0439\u0442\u0440\u0430\u043b\u0438 \u0434\u043b\u044f \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f; \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043f\u043e\u043b\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u043b\u0438\u043d\u0438\u0438.<\/td><\/tr><tr><td><strong>\u0417\u0438\u0433\u0437\u0430\u0433<\/strong><\/td><td><strong>Zn \/ Zn<\/strong><\/td><td><strong>\u0412\u0437\u0430\u0438\u043c\u043e\u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0437\u0432\u0435\u0437\u0434\u0430<\/strong><\/td><td>\u0418\u0434\u0435\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0443\u0440\u0430\u0432\u043d\u043e\u0432\u0435\u0448\u0438\u0432\u0430\u043d\u0438\u044f \u043a\u0440\u0430\u0439\u043d\u0435\u0439 \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/td><td>\u0423\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u0435\u0434\u0438 (\u043f\u0440\u0438\u043c\u0435\u0440\u043d\u043e \u043d\u0430 151 \u0422\u041f3\u0422 \u0431\u043e\u043b\u044c\u0448\u0435, \u0447\u0435\u043c \u0432 Star).<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-deciphering-vector-groups\">6. \u0420\u0430\u0441\u0448\u0438\u0444\u0440\u043e\u0432\u043a\u0430 \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0445 \u0433\u0440\u0443\u043f\u043f<\/h2>\n\n\n\n<p>&lt;p&gt;\u0412\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0435 \u0433\u0440\u0443\u043f\u043f\u044b \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u0444\u0430\u0437\u043e\u0432\u043e\u0435 \u0441\u043c\u0435\u0449\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u0441\u0442\u043e\u0440\u043e\u043d\u0430\u043c\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (HV) \u0438 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (LV). \u042d\u0442\u043e \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u0435 \u0434\u043b\u044f &lt;strong&gt;\u041f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430&lt;\/strong&gt;.&lt;\/p&gt;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"6-1-clock-notation-and-phase-shift\">6.1 \u0427\u0430\u0441\u043e\u0432\u0430\u044f \u043d\u043e\u0442\u0430\u0446\u0438\u044f \u0438 \u0444\u0430\u0437\u043e\u0432\u044b\u0439 \u0441\u0434\u0432\u0438\u0433<\/h4>\n\n\n\n<p>\u0412\u0435\u043a\u0442\u043e\u0440\u043d\u0430\u044f \u0433\u0440\u0443\u043f\u043f\u0430 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, <strong>Dyn11<\/strong>) \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u044e \u0441 \u0446\u0438\u0444\u0435\u0440\u0431\u043b\u0430\u0442\u043e\u043c \u0447\u0430\u0441\u043e\u0432, \u0433\u0434\u0435 \u0432\u0435\u043a\u0442\u043e\u0440 \u0412\u041d \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d \u043d\u0430 12 \u0447\u0430\u0441\u0430\u0445 (0\u00b0). \u041a\u0430\u0436\u0434\u044b\u0439 \u201c\u0447\u0430\u0441\u201d \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0441\u043e\u0431\u043e\u0439 \u0444\u0430\u0437\u043e\u0432\u044b\u0439 \u0441\u0434\u0432\u0438\u0433 \u041d\u041d \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0412\u041d \u043d\u0430 30\u00b0.<\/p>\n\n<ul style=\"list-style-type: square; padding-left: 20px;\"> <li><strong>\u0413\u0440\u0443\u043f\u043f\u0430 I (\u0441\u0434\u0432\u0438\u0433 \u043d\u0430 0\u00b0):<\/strong> Yy0, Dd0 \u2014 \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0434\u043b\u044f \u043a\u0440\u0443\u043f\u043d\u044b\u0445 \u043c\u0435\u0436\u0441\u0438\u0441\u0442\u0435\u043c\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439.<\/li> <li><strong>\u0413\u0440\u0443\u043f\u043f\u0430 III (30\u00b0 \u043e\u0442\u0441\u0442\u0430\u0432\u0430\u043d\u0438\u0435):<\/strong> Dy1, Yd1 \u2014 \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0434\u043b\u044f \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u0430.<\/li> <li><strong>\u0413\u0440\u0443\u043f\u043f\u0430 IV (30\u00b0 \u0441\u0432\u0438\u043d\u0446\u0430):<\/strong> <strong>Dyn11<\/strong> \u2014 \u0413\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439.<\/li> <\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-parallel-operation-engineering-criteria\">7. \u041f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u0430\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f: \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u044b\u0435 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438<\/h2>\n\n\n\n<div style=\"background-color: #fff9f9; border: 1px solid #dee2e6; padding: 20px; margin: 25px 0; border-top: 4px solid #dc3545;\"> <strong style=\"color: #dc3545;\">\u0412\u0430\u0436\u043d\u043e\u0435 \u043f\u0440\u0435\u0434\u0443\u043f\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043f\u043e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438:<\/strong> \u041f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435 \u0434\u0432\u0443\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0431\u0435\u0437 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043d\u0438\u0436\u0435\u0443\u043a\u0430\u0437\u0430\u043d\u043d\u044b\u0445 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0435\u0432 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u0442 \u043a \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u0432\u044b\u0445\u043e\u0434\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u0438 \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0430\u0432\u0430\u0440\u0438\u0438. <\/div>\n\n<p>The <strong>\u0427\u0435\u0442\u044b\u0440\u0435 \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0430\u0432\u0438\u043b\u0430<\/strong> \u0434\u043b\u044f \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b:<\/p>\n\n<ul style=\"list-style-type: none; padding-left: 0;\"> <li style=\"padding: 12px; border-bottom: 1px solid #f1f1f1;\"><strong>1. \u0418\u0434\u0435\u043d\u0442\u0438\u0447\u043d\u044b\u0435 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u044b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f:<\/strong> \u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0446\u0438\u0440\u043a\u0443\u043b\u044f\u0446\u0438\u044e \u0442\u043e\u043a\u043e\u0432 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/li> <li style=\"padding: 12px; border-bottom: 1px solid #f1f1f1;\"><strong>2. \u041e\u0434\u043d\u0430 \u0438 \u0442\u0430 \u0436\u0435 \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u0430\u044f \u0433\u0440\u0443\u043f\u043f\u0430:<\/strong> Dyn1 \u0438 Dyn11 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b (\u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0440\u0430\u0437\u043d\u043e\u0441\u0442\u0438 \u0444\u0430\u0437 60\u00b0).<\/li> <li style=\"padding: 12px; border-bottom: 1px solid #f1f1f1;\"><strong>3. \u0421\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 (%Z):<\/strong> \u0414\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u00b110% \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u043f\u043e\u0440\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/li> <li style=\"padding: 12px;\"><strong>4. \u0418\u0434\u0435\u043d\u0442\u0438\u0447\u043d\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0444\u0430\u0437:<\/strong> \u041f\u0435\u0440\u0435\u0434 \u0432\u0432\u043e\u0434\u043e\u043c \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0444\u0430\u0437\u043e\u0432\u043e\u0433\u043e \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u044f.<\/li> <\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"8-application-spotlight-renewable-energy-integration\">8. \u0412 \u0444\u043e\u043a\u0443\u0441\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f: \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438<\/h2>\n\n\n\n<p>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0445 \u0444\u043e\u0442\u043e\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 \u0432\u0435\u0442\u0440\u044f\u043d\u044b\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u043d\u0446\u0438\u0439 \u0441\u043e\u043f\u0440\u044f\u0436\u0435\u043d\u0430 \u0441 \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430\u043c\u0438. \u042d\u0442\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0447\u0430\u0441\u0442\u043e \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e <a href=\"https:\/\/xbrele.com\/ru\/step-up-vs-step-down-transformer-differences\/\" style=\"color: #0fb4ad; text-decoration: underline;\">\u041f\u043e\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u0434\u043b\u044f \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0437\u043d\u0438\u0446\u044b \u043c\u0435\u0436\u0434\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0433\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u0438 \u0438 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0438:<\/p>\n\n<ul> <li><strong>\u0412\u043f\u0440\u044b\u0441\u043a \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430:<\/strong> \u0418\u043d\u0432\u0435\u0440\u0442\u043e\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u0432\u0432\u043e\u0434\u0438\u0442\u044c \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u0438\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0432 \u0441\u0435\u0442\u044c \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u0447\u0442\u043e \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044e \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430.<\/li> <li><strong>\u041f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430:<\/strong> \u041f\u0440\u0435\u0440\u044b\u0432\u0438\u0441\u0442\u044b\u0435 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0435 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0442 \u0442\u0435\u0440\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0446\u0438\u043a\u043b\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043d\u0430 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u0443\u044e \u0431\u0443\u043c\u0430\u0433\u0443.<\/li> <li><strong>\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c:<\/strong> \u0420\u0435\u0441\u0443\u0440\u0441\u044b \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0438\u043d\u0432\u0435\u0440\u0442\u043e\u0440\u043e\u0432 (IBR) \u0433\u0435\u043d\u0435\u0440\u0438\u0440\u0443\u044e\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u0439\u0441\u044f \u0448\u0443\u043c, \u0447\u0442\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0443\u0441\u0438\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0442\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f.<\/li> <\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"9-maintenance-diagnostic-testing\">9. \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435<\/h2>\n\n\n\n<p>\u0414\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0431\u043e\u043b\u0435\u0435 25 \u043b\u0435\u0442 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0441\u0442\u0440\u043e\u0433\u0438\u0439 \u0433\u0440\u0430\u0444\u0438\u043a \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u0438:<\/p>\n\n\n\n<ol style=\"line-height: 2;\"> <li><strong>DGA (\u0430\u043d\u0430\u043b\u0438\u0437 \u0440\u0430\u0441\u0442\u0432\u043e\u0440\u0435\u043d\u043d\u043e\u0433\u043e \u0433\u0430\u0437\u0430):<\/strong> \u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0434\u043b\u044f <a href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/oil-immersed-transformer\/\" style=\"color: #0fb4ad; text-decoration: underline;\">\u041c\u0430\u0441\u043b\u043e\u043f\u043e\u0433\u0440\u0443\u0436\u0435\u043d\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a> \u0434\u043b\u044f \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0432\u043e\u0434\u043e\u0440\u043e\u0434\u0430 (H<sub>2<\/sub>) \u0438 \u0430\u0446\u0435\u0442\u0438\u043b\u0435\u043d (C<sub>2<\/sub>H<sub>2<\/sub>).<\/li> <li><strong>\u0422\u0435\u0441\u0442 TTR (\u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438):<\/strong> \u0414\u043b\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u0438 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u044f \u043c\u0435\u0436\u0432\u0438\u0442\u043a\u043e\u0432\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f.<\/li> <li><strong>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0442\u0430\u043d\u0433\u0435\u043d\u0441\u0430 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u044f:<\/strong> \u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u043e\u0442\u0435\u0440\u044c \u0434\u043b\u044f \u043f\u0440\u043e\u0433\u043d\u043e\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0441\u0442\u0430\u0440\u0435\u043d\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438.<\/li> <\/ol>\n\n<div style=\"background-color: #f0faf9; border: 1px solid #0fb4ad; padding: 15px; margin: 20px 0; border-radius: 4px;\"> <strong style=\"color: #0fb4ad;\">\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435:<\/strong> \u0414\u043b\u044f <a href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/dry-type-transformer\/\" style=\"color: #0fb4ad; text-decoration: underline;\">\u0421\u0443\u0445\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b<\/a>, \u0435\u0436\u0435\u0433\u043e\u0434\u043d\u0430\u044f \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u043a\u0430 <strong>\u0414\u0430\u0442\u0447\u0438\u043a\u0438 PT100<\/strong> \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u044b\u043c\u0438, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043e\u0441\u043d\u043e\u0432\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u043e\u0442 \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0433\u043e\u043d\u0430 \u0432 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043c\u0430\u0441\u043b\u044f\u043d\u043e\u0433\u043e \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f. <\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"10-switchgear-integration-the-xbrele-advantage\">10. \u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f (\u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e XBRELE)<\/h2>\n\n\n\n<p>\u0412\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u044f\u044e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u043e <strong>12\u00d7<\/strong> \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a (<i>I<sub>n<\/sub><\/i>). \u042d\u0442\u043e \u044f\u0432\u043b\u0435\u043d\u0438\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0441\u043b\u043e\u0436\u043d\u043e\u0439 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u043c\u0435\u0440 \u0437\u0430\u0449\u0438\u0442\u044b.<\/p>\n\n<p><a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-manufacturers\/\" style=\"color: #0fb4ad; text-decoration: underline;\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 XBRELE (VCB)<\/a> \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u044b \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u043c\u0435\u0442\u0430\u043b\u043b\u0443\u0440\u0433\u0438\u0438 \u0434\u043b\u044f \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u044d\u0442\u0438\u0445 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0445 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0432. \u0412 \u0441\u043e\u0447\u0435\u0442\u0430\u043d\u0438\u0438 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c\u0438 \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0449\u0438\u043c\u0438 <strong>ANSI 87T (\u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439)<\/strong> \u0438 <strong>ANSI 50\/51 (\u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443)<\/strong> \u043a\u043e\u0434\u044b, \u043d\u0430\u0448\u0435 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0437\u0430\u0449\u0438\u0442\u0443 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043e\u0442 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044f \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u0438 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"11-troubleshooting-faq\">11. \u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e \u043d\u0435\u043f\u043e\u043b\u0430\u0434\u043e\u043a<\/h2>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441: \u041f\u043e\u0447\u0435\u043c\u0443 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u201c\u0433\u0443\u0434\u0438\u0442\u201d?<\/strong> A: \u042d\u0442\u043e &lt;strong&gt;\u041c\u0430\u0433\u043d\u0438\u0442\u043e\u0441\u0442\u0440\u0438\u043a\u0446\u0438\u044f&lt;\/strong&gt;&mdash; \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u043b\u0430\u043c\u0438\u043d\u0430\u0446\u0438\u0438 \u0438\u0437-\u0437\u0430 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430. \u0427\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u044b\u0439 \u0448\u0443\u043c \u043e\u0431\u044b\u0447\u043d\u043e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u0438\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u044b\u0439 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a (\u0432\u044b\u0441\u043e\u043a\u0438\u0439 &lt;i&gt;V\/f&lt;\/i&gt;) \u0438\u043b\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0441\u043b\u0430\u0431\u043b\u0435\u043d\u0438\u0435 \u0431\u043e\u043b\u0442\u043e\u0432 \u0437\u0430\u0436\u0438\u043c\u0430 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430.<\/p>\n\n\n\n<p><strong>\u0412: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u044c \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b Yy0 \u0438 Dd0?<\/strong> A: \u0414\u0430, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u0431\u0430 \u043e\u0442\u043d\u043e\u0441\u044f\u0442\u0441\u044f \u043a \u0433\u0440\u0443\u043f\u043f\u0435 I (\u0441\u0434\u0432\u0438\u0433 0\u00b0). \u041e\u0434\u043d\u0430\u043a\u043e \u0432\u0441\u0435 \u043e\u0441\u0442\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b, \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a %Z \u0438 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0434\u043e\u043b\u0436\u043d\u044b \u0441\u043e\u0432\u043f\u0430\u0434\u0430\u0442\u044c.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion-engineering-for-longevity\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435: \u0418\u043d\u0436\u0435\u043d\u0435\u0440\u0438\u044f \u0434\u043b\u044f \u0434\u043e\u043b\u0433\u043e\u043b\u0435\u0442\u0438\u044f<\/h2>\n\n\n\n<p>\u0422\u043e\u0447\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0445 \u0433\u0440\u0443\u043f\u043f \u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0439 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0435\u0439 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438\u043c\u0435\u044e\u0442 \u0440\u0435\u0448\u0430\u044e\u0449\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u044b. \u0412 <strong>XBRELE<\/strong>, \u041c\u044b \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u043c \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043f\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c IEC VCB \u0438 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b, \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u043e\u0432.<\/p>\n\n\n\n<div class=\"xbrele-classic-card\">\n    <div class=\"card-inner\">\n        <div class=\"card-thumb\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/download-icon.webp\" alt=\"\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c PDF\">\n        <\/div>\n        <div class=\"card-details\">\n            <span class=\"card-label\">\u041e\u0444\u0438\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u044b\u043c \u0440\u0430\u0431\u043e\u0442\u0430\u043c<\/span>\n            <h3>3-\u0444\u0430\u0437\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b: \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0435 \u0433\u0440\u0443\u043f\u043f\u044b \u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432 \u0441\u0435\u0442\u044c<\/h3>\n            <p>\u041e\u0441\u0432\u043e\u0439\u0442\u0435 \u0441\u043b\u043e\u0436\u043d\u044b\u0435 \u0430\u0441\u043f\u0435\u043a\u0442\u044b \u0431\u0430\u043b\u0430\u043d\u0441\u0430 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430, \u0432\u0435\u043a\u0442\u043e\u0440\u043d\u043e\u0439 \u0433\u0440\u0443\u043f\u043f\u044b \u0414\u041d\u041a Dyn11 \u0438 \u0447\u0435\u0442\u044b\u0440\u0435\u0445 \u0437\u043e\u043b\u043e\u0442\u044b\u0445 \u043f\u0440\u0430\u0432\u0438\u043b \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b. \u042d\u0442\u043e \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c IEC, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0439 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n            <div class=\"card-meta\">\n                <span><i class=\"far fa-file-pdf\"><\/i> **\u0424\u043e\u0440\u043c\u0430\u0442:** \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442 PDF<\/span>\n                <span><i class=\"far fa-user\"><\/i> **\u0410\u0432\u0442\u043e\u0440:** XBRELE Engineering<\/span>\n            <\/div>\n            <a href=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele.com-Ultimate-Technical-Guide-to-3-Phase-Transformers.pdf\" class=\"card-download-btn\" target=\"_blank\" rel=\"noopener\">\n                <i class=\"fas fa-file-download\"><\/i> \u0421\u043a\u0430\u0447\u0430\u0442\u044c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e\n            <\/a>\n        <\/div>\n    <\/div>\n<\/div>\n\n<style>\n.xbrele-classic-card { background: #fdfdfd; border: 1px solid #e1e4e8; border-left: 6px solid #0fb4ad; padding: 28px; margin: 35px 0; border-radius: 4px; font-family: sans-serif; }\n.card-inner { display: flex; gap: 30px; align-items: center; }\n.card-thumb img { width: 130px; }\n.card-label { color: #0fb4ad; font-size: 12px; font-weight: 800; display: block; }\n.card-details h3 { margin: 5px 0; font-size: 22px; color: #1a1a1a; line-height: 1.3; }\n.card-details p { font-size: 14px; color: #586069; margin: 10px 0; }\n.card-meta { font-size: 13px; color: #959da5; display: flex; gap: 20px; margin-bottom: 20px; }\n.card-download-btn { background-color: #0fb4ad; color: #fff !important; padding: 12px 25px; border-radius: 3px; text-decoration: none; font-weight: 700; display: inline-flex; align-items: center; gap: 10px; transition: background 0.3s; }\n.card-download-btn:hover { background-color: #0d968f; }\n@media (max-width: 650px) { .card-inner { flex-direction: column; text-align: center; } .card-meta { justify-content: center; } }\n<\/style>","protected":false},"excerpt":{"rendered":"<p>Technical Level: Intermediate to Advanced Applicable Standards: IEC 60076, IEEE C57.12.00 1. Introduction: The Strategic Role of Transformers in Modern Grids In the hierarchy of power system assets, the 3-phase transformer is the most critical node. Beyond simple voltage transformation, it acts as a harmonic filter, a tool for grounding strategy, and a robust barrier [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2241,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-2238","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2238","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2238"}],"version-history":[{"count":6,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2238\/revisions"}],"predecessor-version":[{"id":3819,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2238\/revisions\/3819"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2241"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2238"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2238"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}