{"id":2269,"date":"2025-12-22T07:00:32","date_gmt":"2025-12-22T07:00:32","guid":{"rendered":"https:\/\/xbrele.com\/?p=2269"},"modified":"2026-05-25T14:46:27","modified_gmt":"2026-05-25T14:46:27","slug":"vacuum-circuit-breaker-ratings","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-ratings\/","title":{"rendered":"\u041f\u043e\u044f\u0441\u043d\u0435\u043d\u0438\u044f \u043a \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u0430\u043c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439: \u043a\u0412, \u043a\u0410, BIL, Icw, Duty"},"content":{"rendered":"\ufeff\n<!-- QUICK TAKEAWAY (replace TOC; keep your TOC plugin enabled) -->\n<section id=\"quick-takeaway\" style=\"margin:24px 0; padding:18px 18px; border:1px solid #e5e7eb; border-radius:14px; background:#ffffff;\">\n  <div style=\"display:flex; gap:12px; align-items:flex-start;\">\n    <div aria-hidden=\"true\" style=\"flex:0 0 auto; width:40px; height:40px; border-radius:10px; background:#00B8B8; display:flex; align-items:center; justify-content:center;\">\n      <svg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\">\n        <path d=\"M12 2l1.7 5.4H19l-4.3 3.1 1.7 5.4L12 12.8 7.6 15.9 9.3 10.5 5 7.4h5.3L12 2z\" fill=\"#ffffff\"\/>\n      <\/svg>\n    <\/div>\n\n    <div style=\"flex:1 1 auto;\">\n      <p style=\"margin:0 0 6px 0; font-size:14px; font-weight:700; color:#0f172a; letter-spacing:0.2px;\">\n        \u041a\u0440\u0430\u0442\u043a\u043e\u0435 \u0440\u0435\u0437\u044e\u043c\u0435 (60 \u0441\u0435\u043a\u0443\u043d\u0434)\n      <\/p>\n      <p style=\"margin:0 0 10px 0; color:#334155; font-size:14px; line-height:1.6;\">\n        \u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 VCB \u043d\u0435 \u0441\u0432\u043e\u0434\u0438\u0442\u0441\u044f \u043a \u201c\u043a\u0412 + \u0410\u201d. \u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c <strong>\u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/strong> (\u043a\u043b\u0430\u0441\u0441 \u043a\u0412 + BIL\/LIWV),\n        <strong>\u0434\u0435\u0436\u0443\u0440\u0441\u0442\u0432\u043e \u043f\u043e \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u043c<\/strong> (\u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 kA + Icw + \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u0435\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435 \u0437\u0430\u0449\u0435\u043b\u043a\u0438) \u0438 <strong>\u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u044b<\/strong> (TRV\/RRRV) \u043f\u0440\u043e\u0442\u0438\u0432 <strong>\u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432 \u043c\u0435\u0441\u0442\u0435 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f<\/strong> \u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC\/IEEE \u043f\u0440\u043e\u0435\u043a\u0442\u0430.\n      <\/p>\n\n      <div style=\"display:flex; flex-wrap:wrap; gap:8px; margin:0 0 10px 0;\">\n        <span style=\"display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border:1px solid #e5e7eb; border-radius:999px; font-size:12px; color:#0f172a; background:#f8fafc;\">\n          <span aria-hidden=\"true\" style=\"width:8px; height:8px; border-radius:999px; background:#00B8B8;\"><\/span>\n          \u043a\u0412 \/ Ur: \u043a\u043b\u0430\u0441\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f\n        <\/span>\n        <span style=\"display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border:1px solid #e5e7eb; border-radius:999px; font-size:12px; color:#0f172a; background:#f8fafc;\">\n          <span aria-hidden=\"true\" style=\"width:8px; height:8px; border-radius:999px; background:#00B8B8;\"><\/span>\n          A \/ Ir: \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u043f\u0440\u0435\u0434\u0435\u043b\n        <\/span>\n        <span style=\"display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border:1px solid #e5e7eb; border-radius:999px; font-size:12px; color:#0f172a; background:#f8fafc;\">\n          <span aria-hidden=\"true\" style=\"width:8px; height:8px; border-radius:999px; background:#00B8B8;\"><\/span>\n          kA \/ Isc: \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435\n        <\/span>\n        <span style=\"display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border:1px solid #e5e7eb; border-radius:999px; font-size:12px; color:#0f172a; background:#f8fafc;\">\n          <span aria-hidden=\"true\" style=\"width:8px; height:8px; border-radius:999px; background:#00B8B8;\"><\/span>\n          Icw: \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0432\u0440\u0435\u043c\u044f\n        <\/span>\n        <span style=\"display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border:1px solid #e5e7eb; border-radius:999px; font-size:12px; color:#0f172a; background:#f8fafc;\">\n          <span aria-hidden=\"true\" style=\"width:8px; height:8px; border-radius:999px; background:#00B8B8;\"><\/span>\n          BIL\/LIWV: \u0437\u0430\u043f\u0430\u0441 \u043f\u043e \u043f\u0435\u0440\u0435\u043f\u0430\u0434\u0430\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\n        <\/span>\n        <span style=\"display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border:1px solid #e5e7eb; border-radius:999px; font-size:12px; color:#0f172a; background:#f8fafc;\">\n          <span aria-hidden=\"true\" style=\"width:8px; height:8px; border-radius:999px; background:#00B8B8;\"><\/span>\n          TRV\/RRRV: \u0440\u0438\u0441\u043a \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0443\u0434\u0430\u0440\u0430\n        <\/span>\n      <\/div>\n\n      <p style=\"margin:0; color:#475569; font-size:12px; line-height:1.6;\">\n        <strong>\u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u0440\u0430\u0432\u0438\u043b\u043e:<\/strong> \u041e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u0441\u044c \u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c\u0443 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044e \u043a\u0430\u043a \u043a \u0441\u0435\u043c\u044c\u0435 \u2014\n        <strong>\u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 (\u043a\u0410)<\/strong> + <strong>\u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430 (Icw)<\/strong> + <strong>\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435\/\u0437\u0430\u043a\u0440\u044b\u0442\u044b\u0439 \u0437\u0430\u043c\u043e\u043a<\/strong>. \u0415\u0441\u043b\u0438 \u0432\u0430\u0448\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0441\u043e\u0434\u0435\u0440\u0436\u0438\u0442 \u043c\u043d\u043e\u0433\u043e \u043a\u0430\u0431\u0435\u043b\u0435\u0439 \u0438\u043b\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432, \u0434\u043e\u0431\u0430\u0432\u044c\u0442\u0435 \u044f\u0432\u043d\u043e\u0435 <strong>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 TRV<\/strong>.\n      <\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n\n\n<p>\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0435 \u043f\u0440\u043e\u0449\u0430\u044e\u0442 \u043e\u0448\u0438\u0431\u043e\u043a \u0432 \u0440\u0430\u0441\u0447\u0435\u0442\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a. \u0412 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u043e\u0431\u044a\u044f\u0441\u043d\u044f\u044e\u0442\u0441\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 (VCB) \u0441 \u0442\u043e\u0447\u043a\u0438 \u0437\u0440\u0435\u043d\u0438\u044f \u0438\u0445 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0430\u043c\u0438: <strong>\u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043d\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0430 \u2192 \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u2192 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/strong>.<\/p>\n\n\n\n<p>\u0415\u0441\u043b\u0438 \u0432\u044b \u0445\u043e\u0442\u0438\u0442\u0435 \u0441\u043d\u0430\u0447\u0430\u043b\u0430 \u043e\u0437\u043d\u0430\u043a\u043e\u043c\u0438\u0442\u044c\u0441\u044f \u0441 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u043c\u0438 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u0430\u043c\u0438, \u043f\u0440\u043e\u0447\u0442\u0438\u0442\u0435:<br><a href=\"https:\/\/xbrele.com\/ru\/what-is-vacuum-circuit-breaker-working-principle\/\">\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (VCB) \u0438 \u043a\u0430\u043a \u043e\u043d \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442?<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-nameplate-decoder-figure-01.webp\" alt=\"\u0421\u0445\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043d\u043e\u0439 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0441 \u0432\u044b\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u0437\u043e\u043d\u0430\u043c\u0438 \u0434\u043b\u044f \u043f\u043e\u043b\u0435\u0439 Ur, Ir, Isc, Icw \u0438 BIL\" class=\"wp-image-2270\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-nameplate-decoder-figure-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-nameplate-decoder-figure-01-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-nameplate-decoder-figure-01-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-nameplate-decoder-figure-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 1. \u041e\u0431\u0449\u0430\u044f \u0441\u0445\u0435\u043c\u0430 \u0434\u0435\u043a\u043e\u0434\u0435\u0440\u0430 \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043d\u043e\u0439 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438 VCB \u2014 \u0437\u043e\u043d\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u043f\u043e\u043b\u044f\u043c Ur, Ir, Isc, Icw, BIL\/LIWV \u0438 TRV.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-vcb-ratings-really-mean-and-why-kv-a-is-not-enough\">\u0427\u0442\u043e \u043d\u0430 \u0441\u0430\u043c\u043e\u043c \u0434\u0435\u043b\u0435 \u043e\u0437\u043d\u0430\u0447\u0430\u044e\u0442 \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0438 VCB (\u0438 \u043f\u043e\u0447\u0435\u043c\u0443 \u201c\u043a\u0412 + A\u201d \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e)<\/h2>\n\n\n\n<p>\u0411\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043f\u0440\u043e\u0431\u043b\u0435\u043c \u0441 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f\u043c\u0438 MV \u043d\u0435 \u0441\u0432\u044f\u0437\u0430\u043d\u044b \u0441 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0435\u0439. \u041e\u0431\u044b\u0447\u043d\u043e \u043e\u043d\u0438 \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u044e\u0442 \u0438\u0437-\u0437\u0430 \u043e\u0434\u043d\u043e\u0433\u043e \u0438\u0437 \u0442\u0440\u0435\u0445 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0439:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439 \u0440\u0430\u0437\u043b\u043e\u043c\u0430:<\/strong> \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u043b\u043e\u0441\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 (\u043a\u0410), \u043d\u043e <strong>\u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430 (Icw)<\/strong> \u0438\/\u0438\u043b\u0438 <strong>\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435\/\u0437\u0430\u043a\u0440\u044b\u0442\u044b\u0439 \u0437\u0430\u043c\u043e\u043a<\/strong> \u0431\u044b\u043b\u0438 \u043f\u0440\u043e\u0438\u0433\u043d\u043e\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u044b.<\/li>\n\n\n\n<li><strong>\u041d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438:<\/strong> \u043a\u043b\u0430\u0441\u0441 \u043a\u0412 \u0438\u043b\u0438 <strong>BIL\/LIWV<\/strong> \u043d\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u043c \u043e \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0438 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u0435\u043b\u044f\u0445.<\/li>\n\n\n\n<li><strong>\u0412\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0435 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 (TRV):<\/strong> \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u0443 kA, \u043d\u043e <strong>TRV\/RRRV<\/strong> \u0431\u043e\u043b\u0435\u0435 \u0436\u0435\u0441\u0442\u043a\u0438\u043c \u0432 \u0441\u0435\u0442\u044f\u0445 \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435\u0439\/\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432.<\/li>\n<\/ul>\n\n\n\n<p>\u042d\u0442\u0430 \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430 \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0430 \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0442\u0430\u043a\u0438\u0445 \u043e\u0448\u0438\u0431\u043e\u043a.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 (VCB): \u043e\u0431\u044a\u044f\u0441\u043d\u0435\u043d\u0438\u0435 kV, kA, BIL \u0438 TRV\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/2u4gtkL4RxM?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quick-nameplate-decoder-60-seconds\">\u0411\u044b\u0441\u0442\u0440\u044b\u0439 \u0434\u0435\u043a\u043e\u0434\u0435\u0440 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438 \u0441 \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c (60 \u0441\u0435\u043a\u0443\u043d\u0434)<\/h2>\n\n\n\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u044d\u0442\u0443 \u0442\u0430\u0431\u043b\u0438\u0446\u0443 \u0434\u043b\u044f \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0432\u043e\u0434\u0430 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043e\u0432\/\u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043d\u044b\u0445 \u0442\u0430\u0431\u043b\u0438\u0447\u0435\u043a VCB.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u042d\u0442\u0438\u043a\u0435\u0442\u043a\u0430 \u0441 \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c<\/th><th>\u0427\u0442\u043e \u044d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u043d\u0430 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435<\/th><th>\u041e\u0431\u0449\u0438\u0435 \u0441\u0438\u043c\u0432\u043e\u043b\u044b\/\u043c\u0435\u0442\u043a\u0438<\/th><\/tr><\/thead><tbody><tr><td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u043b\u0430\u0441\u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/td><td>\u041a\u043b\u0430\u0441\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f (\u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f\/\u0437\u0430\u0437\u043e\u0440\u044b)<\/td><td>\u043a\u0412, <strong>\u0423\u0440<\/strong>, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td><\/tr><tr><td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0439 \u0442\u043e\u043a<\/td><td>\u041f\u0440\u043e\u0432\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u0442\u043e\u043a\u0430 \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e\u0433\u043e \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b<\/td><td>A, <strong>\u0418\u0440<\/strong><\/td><\/tr><tr><td>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435\/\u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/td><td>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043e\u043d \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0432 \u0442\u0435\u0441\u0442\u043e\u0432\u043e\u043c \u0440\u0435\u0436\u0438\u043c\u0435<\/td><td>kA, <strong>Isc<\/strong><\/td><\/tr><tr><td>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u0430\u044f \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/td><td>\u041f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u043e\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\u043c\u0438<\/td><td><strong>BIL<\/strong>, <strong>LIWV<\/strong> (\u043a\u0412\u043f)<\/td><\/tr><tr><td>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 TRV<\/td><td>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f (\u043f\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c)<\/td><td>TRV \/ \u043a\u043b\u0430\u0441\u0441 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438<\/td><\/tr><tr><td>\u041a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430<\/td><td>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 (\u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438)<\/td><td><strong>Icw<\/strong> (1 \u0441\/3 \u0441)<\/td><\/tr><tr><td>\u0418\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \/ \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435 \u0438 \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u044f<\/td><td>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0431\u043b\u0438\u0437\u043a\u0438\u043c \u0441\u0431\u043e\u044f\u043c (\u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u0441\u0438\u043b\u044b)<\/td><td>\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \/ \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435 \u0438 \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u044f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"glossary-of-symbols-quick-reference\">\u0413\u043b\u043e\u0441\u0441\u0430\u0440\u0438\u0439 \u0441\u0438\u043c\u0432\u043e\u043b\u043e\u0432 (\u043a\u0440\u0430\u0442\u043a\u0438\u0439 \u0441\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u0438\u043a)<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0423\u0440:<\/strong> \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 (\u043a\u043b\u0430\u0441\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f)<\/li>\n\n\n\n<li><strong>Ir:<\/strong> \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0439 \u0442\u043e\u043a (\u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u043f\u0440\u0435\u0434\u0435\u043b)<\/li>\n\n\n\n<li><strong>Isc:<\/strong> \u0442\u043e\u043a \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f\/\u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (\u0447\u0430\u0441\u0442\u043e \u043e\u0431\u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442\u0441\u044f \u043a\u0430\u043a RMS \u0432 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u0445)<\/li>\n\n\n\n<li><strong>Icw:<\/strong> \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0441\u0438\u043b\u0430 \u0442\u043e\u043a\u0430 (\u0441 \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c: 1 \u0441, 3 \u0441 \u0438 \u0442. \u0434.)<\/li>\n\n\n\n<li><strong>BIL \/ LIWV:<\/strong> \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 \u043a \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u0430\u043c \u043c\u043e\u043b\u043d\u0438\u0438 (\u043a\u0412\u043f)<\/li>\n\n\n\n<li><strong>TRV:<\/strong> \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430 (\u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f)<\/li>\n\n\n\n<li><strong>RRRV:<\/strong> \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u043d\u0430\u0440\u0430\u0441\u0442\u0430\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f (\u0447\u0430\u0441\u0442\u044c \u0441\u0442\u0440\u043e\u0433\u043e\u0441\u0442\u0438 TRV)<\/li>\n\n\n\n<li><strong>X\/R:<\/strong> \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u0440\u0435\u0430\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u043a \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044e (\u0432\u043b\u0438\u044f\u0435\u0442 \u043d\u0430 \u0441\u043c\u0435\u0449\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438 \u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u0441\u0438\u043b\u044b)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"iec-vs-ieee-terminology-crosswalk\">\u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u0442\u0435\u0440\u043c\u0438\u043d\u043e\u043b\u043e\u0433\u0438\u0438 IEC \u0438 IEEE<\/h2>\n\n\n\n<p>\u041e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u044b\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438, \u0440\u0430\u0437\u043d\u044b\u0435 \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u044f. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u0434\u043e\u0441\u0442\u043e\u0432\u0435\u0440\u043d\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u041a\u043e\u043d\u0446\u0435\u043f\u0446\u0438\u044f<\/th><th>\u041e\u0431\u0449\u0430\u044f \u0444\u043e\u0440\u043c\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0430 \u041c\u042d\u041a<\/th><th>\u041e\u0431\u0449\u0430\u044f \u0444\u043e\u0440\u043c\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0430 IEEE<\/th><th>\u041f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435<\/th><\/tr><\/thead><tbody><tr><td>\u041a\u043b\u0430\u0441\u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/td><td><strong>\u0423\u0440<\/strong><\/td><td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td><td>\u041e\u0431\u0430 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u043a\u043b\u0430\u0441\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f\/\u043e\u0441\u043d\u043e\u0432\u0443 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438<\/td><\/tr><tr><td>\u041d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u044b\u0439 \u0442\u043e\u043a<\/td><td><strong>\u0418\u0440<\/strong><\/td><td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0439 \u0442\u043e\u043a<\/td><td>\u041f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \/ \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u0440\u0430\u0441\u0447\u0435\u0442<\/td><\/tr><tr><td>\u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c<\/td><td>\u0422\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/td><td>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0430<\/td><td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u0435 \u0442\u0443 \u0436\u0435 \u043e\u0441\u043d\u043e\u0432\u0443 \u0432 \u0432\u0430\u0448\u0435\u0439 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438<\/td><\/tr><tr><td>\u041a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430<\/td><td><strong>Icw<\/strong><\/td><td>\u041a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430<\/td><td>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0434\u043b\u044f \u0437\u0430\u0434\u0435\u0440\u0436\u0435\u043a \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438<\/td><\/tr><tr><td>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0441\u0431\u043e\u044f\u043c<\/td><td>\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \/ \u043f\u0438\u043a\u043e\u0432\u0430\u044f \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c (\u0444\u043e\u0440\u043c\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0430 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u0430 \u043c\u043e\u0436\u0435\u0442 \u0432\u0430\u0440\u044c\u0438\u0440\u043e\u0432\u0430\u0442\u044c\u0441\u044f)<\/td><td>\u0437\u0430\u043a\u0440\u044b\u0442\u044c \u0438 \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u0442\u044c \/ \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435<\/td><td>\u041f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u0430<\/td><\/tr><tr><td>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u0430\u043c<\/td><td>LIWV \/ BIL<\/td><td>BIL<\/td><td>\u0427\u0430\u0441\u0442\u043e \u043f\u0438\u0448\u0435\u0442\u0441\u044f \u043a\u0430\u043a BIL \u0432 \u043e\u0431\u043e\u0438\u0445 \u043c\u0438\u0440\u0430\u0445.<\/td><\/tr><tr><td>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 TRV<\/td><td>TRV \u0437\u0430 \u0442\u0435\u0441\u0442\u043e\u0432\u044b\u0435 \u043e\u0431\u044f\u0437\u0430\u043d\u043d\u043e\u0441\u0442\u0438<\/td><td>TRV \u0437\u0430 \u0442\u0435\u0441\u0442\u043e\u0432\u044b\u0435 \u043e\u0431\u044f\u0437\u0430\u043d\u043d\u043e\u0441\u0442\u0438<\/td><td>\u0422\u0438\u043f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0438\u043c\u0435\u0435\u0442 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 (\u043a\u0430\u0431\u0435\u043b\u0438\/\u043a\u043e\u043b\u043f\u0430\u0447\u043a\u0438)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-7-key-insights-the-ratings-that-decide-success\">7 \u043a\u043b\u044e\u0447\u0435\u0432\u044b\u0445 \u0432\u044b\u0432\u043e\u0434\u043e\u0432 (\u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0438, \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0449\u0438\u0435 \u0443\u0441\u043f\u0435\u0445)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-kv-rating-equipment-class-insulation-design-not-the-feeder-nickname\">1) \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432 \u043a\u0412 = \u043a\u043b\u0430\u0441\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f + \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 (\u043d\u0435 \u043f\u0440\u043e\u0437\u0432\u0438\u0449\u0435 \u0444\u0438\u0434\u0435\u0440\u0430)<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u041a\u043b\u0430\u0441\u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0449\u0438\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0437\u0430\u0437\u043e\u0440\u044b \u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435.<br><strong>\u0427\u0442\u043e \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c:<\/strong> \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u201c\u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0441\u0438\u0441\u0442\u0435\u043c\u044b\u201d \u0432 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 \u043a \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u043c\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e \u043b\u0438\u043d\u0435\u0439\u043a\u0438.<br><strong>\u0415\u0441\u043b\u0438 \u043d\u0435\u0434\u043e\u043e\u0446\u0435\u043d\u0435\u043d:<\/strong> \u0447\u0430\u0441\u0442\u0438\u0447\u043d\u044b\u0439 \u0440\u0430\u0437\u0440\u044f\u0434, \u043f\u0435\u0440\u0435\u0431\u043e\u0439, \u0440\u0438\u0441\u043a \u0432\u044b\u0445\u043e\u0434\u0430 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f.<\/p>\n\n\n\n<p>\u0421\u0442\u0440\u0430\u043d\u0438\u0446\u044b \u043a\u043e\u043d\u0442\u0435\u043a\u0441\u0442\u0430 (\u043d\u0435\u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u043e):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-manufacturers\/\">\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u0438 OEM-\u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-a-rating-ir-is-thermal-engineering-not-load-equals-rating\">2) \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c (Ir) \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0442\u0435\u043f\u043b\u043e\u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u043e\u043c, \u0430 \u043d\u0435 \u201c\u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439, \u0440\u0430\u0432\u043d\u043e\u0439 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438\u201d.\u201d<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u044b\u0439 \u0442\u043e\u043a \u043f\u0440\u0438 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e\u043c \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b.<br><strong>\u0427\u0442\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u044e\u0442 \u043e\u043f\u044b\u0442\u043d\u044b\u0435 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u044b \u043f\u043e\u043c\u0438\u043c\u043e Ir:<\/strong> \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b, \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u044f \u043a\u0430\u0431\u0438\u043d\u044b, \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u044b\u0439 \u0440\u0430\u0431\u043e\u0447\u0438\u0439 \u0446\u0438\u043a\u043b, \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0443\u0440\u043e\u0432\u043d\u0435\u043c \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a, \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0432 \u0433\u043e\u0440\u044f\u0447\u0438\u0445 \u0442\u043e\u0447\u043a\u0430\u0445.<br><strong>\u0415\u0441\u043b\u0438 \u043d\u0435\u0434\u043e\u043e\u0446\u0435\u043d\u0435\u043d:<\/strong> \u0445\u0440\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043d\u0430\u0433\u0440\u0435\u0432\u0430\u043d\u0438\u0435 \u2192 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u2192 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u043d\u044b\u0439 \u0438\u0437\u043d\u043e\u0441.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-ka-interrupting-rating-is-only-one-part-of-short-circuit-capability\">3) \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c \u043a \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044e \u0442\u043e\u043a\u0430 3 \u043a\u0410 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043b\u0438\u0448\u044c \u043e\u0434\u043d\u043e\u0439 \u0438\u0437 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0445 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u0438 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435.<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u043f\u0440\u0438 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u0445.<br><strong>\u041f\u0440\u0430\u0432\u0438\u043b\u043e \u043e\u0442\u0431\u043e\u0440\u0430:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 <strong>\u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432 \u043c\u0435\u0441\u0442\u0435 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f<\/strong>, \u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0430\u0432\u0442\u043e\u0431\u0443\u0441\u0430.<br><strong>\u0415\u0441\u043b\u0438 \u043d\u0435\u0434\u043e\u043e\u0446\u0435\u043d\u0435\u043d:<\/strong> \u043d\u0435\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435, \u0440\u0438\u0441\u043a \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u043e\u0433\u043e \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4-icw-decides-whether-selectivity-is-feasible\">4) Icw \u0440\u0435\u0448\u0430\u0435\u0442, \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u0430 \u043b\u0438 \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u0422\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 (\u0447\u0430\u0441\u0442\u043e 1 \u0441 \u0438\u043b\u0438 3 \u0441).<br><strong>\u041f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0432\u0430\u0436\u043d\u043e:<\/strong> \u0417\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u0432 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u043e\u0437\u043d\u0430\u0447\u0430\u044e\u0442, \u0447\u0442\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u044b\u0448\u0435 \u043f\u043e \u0446\u0435\u043f\u043e\u0447\u043a\u0435 \u0434\u043e\u043b\u0436\u043d\u043e \u0432\u044b\u0434\u0435\u0440\u0436\u0430\u0442\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0435\u0434 \u043e\u0447\u0438\u0441\u0442\u043a\u043e\u0439.<br><strong>\u0415\u0441\u043b\u0438 \u043d\u0435\u0434\u043e\u043e\u0446\u0435\u043d\u0435\u043d:<\/strong> \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u043e\u0438\u0437\u043e\u0439\u0442\u0438 \u0434\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f, \u0438\u043b\u0438 \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0441\u0442\u0430\u043d\u0435\u0442 \u043d\u0435\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5-making-close-latch-is-the-hidden-limiter\">5) \u0417\u0430\u043a\u0440\u044b\u0442\u0438\u0435\/\u0437\u0430\u0449\u0435\u043b\u043a\u0430 \u2014 \u044d\u0442\u043e \u201c\u0441\u043a\u0440\u044b\u0442\u044b\u0439 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u0435\u043b\u044c\u201d<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u0421\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u0440\u0438 \u0431\u043b\u0438\u0437\u043a\u043e\u043c \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438 \u043a \u0440\u0430\u0437\u043b\u043e\u043c\u0443 (\u0447\u0430\u0441\u0442\u043e \u0441\u0430\u043c\u044b\u0439 \u0442\u044f\u0436\u0435\u043b\u044b\u0439 \u0441\u043b\u0443\u0447\u0430\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f).<br><strong>\u041f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0432\u0430\u0436\u043d\u043e:<\/strong> \u0412 \u0441\u0435\u0442\u044f\u0445 \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0441\u043e\u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435\u043c X\/R \u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0434\u0438\u043d\u0430\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u043b\u044b \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u043f\u0440\u0435\u0434\u0435\u043b\u044c\u043d\u044b\u043c \u0441\u043b\u0443\u0447\u0430\u0435\u043c.<br><strong>\u0415\u0441\u043b\u0438 \u043d\u0435\u0434\u043e\u043e\u0446\u0435\u043d\u0435\u043d:<\/strong> \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435\/\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f, \u043e\u0442\u0441\u043a\u043e\u043a, \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b.<\/p>\n\n\n\n<p><strong>\u041f\u0440\u0430\u043a\u0442\u0438\u0447\u043d\u0430\u044f \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0430\u044f \u043e\u0448\u0438\u0431\u043a\u0438:<\/strong><br>\u0421\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u043e \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439 = <strong>\u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 (\u043a\u0410) + \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0441\u0438\u043b\u0430 \u0442\u043e\u043a\u0430 (Icw) + \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\/\u0437\u0430\u043f\u043e\u0440<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-short-circuit-family-figure-02.webp\" alt=\"\u0422\u0440\u0438\u0430\u0434\u043d\u0430\u044f \u0434\u0438\u0430\u0433\u0440\u0430\u043c\u043c\u0430, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043b\u044f VCB: \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 kA, \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430 Icw \u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0441 \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u0435\u0439\" class=\"wp-image-2271\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-short-circuit-family-figure-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-short-circuit-family-figure-02-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-short-circuit-family-figure-02-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-short-circuit-family-figure-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 2. \u0421\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u2014 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 (\u043a\u0410), \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0441\u0438\u043b\u0430 \u0442\u043e\u043a\u0430 (Icw) \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\/\u0437\u0430\u043f\u0438\u0440\u0430\u043d\u0438\u044f \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432\u043c\u0435\u0441\u0442\u0435.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6-bil-liwv-is-insulation-coordination-in-one-number\">6) BIL \/ LIWV \u2014 \u044d\u0442\u043e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0432 \u043e\u0434\u043d\u043e\u043c \u0447\u0438\u0441\u043b\u0435.<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u0430\u043c \u043c\u043e\u043b\u043d\u0438\u0438 \u0432 \u043a\u0412\u043f (\u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u044b\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0439 \u0437\u0430\u043f\u0430\u0441).<br><strong>\u0427\u0442\u043e \u043d\u0443\u0436\u043d\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c:<\/strong> \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 BIL, \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0438 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u0435\u043b\u0435\u0439, \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0435 \u043b\u0438\u043d\u0438\u0438 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u043e\u0439 \u0441\u0435\u0442\u044c\u044e, \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u043b\u0438\u043d\u0438\u0438 (\u0448\u0438\u043d\u0430, \u043e\u043a\u043e\u043d\u0435\u0447\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, CT\/PT).<br><strong>\u0415\u0441\u043b\u0438 \u043d\u0435\u0434\u043e\u043e\u0446\u0435\u043d\u0435\u043d:<\/strong> \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u0430\u044f \u043f\u0440\u043e\u0431\u043e\u0438\u043d\u0430 \u0438\u043b\u0438 \u0441\u043a\u0440\u044b\u0442\u043e\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"7-trv-explains-restrike-events-that-shouldn-t-happen\">7) TRV \u043e\u0431\u044a\u044f\u0441\u043d\u044f\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u044f \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u201c\u043d\u0435 \u0434\u043e\u043b\u0436\u043d\u044b \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442\u044c\u201d<\/h3>\n\n\n\n<p><strong>\u0427\u0442\u043e \u044d\u0442\u043e \u0442\u0430\u043a\u043e\u0435:<\/strong> \u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u0445 \u0441\u0440\u0430\u0437\u0443 \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f; \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u044b \u0438 <strong>RRRV<\/strong>.<br><strong>\u041f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0432\u0430\u0436\u043d\u043e:<\/strong> \u041a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u043f\u0438\u0442\u0430\u044e\u0449\u0438\u0435 \u043b\u0438\u043d\u0438\u0438 \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435\u0439 \u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u043c\u043e\u0433\u0443\u0442 \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u0442\u044c \u0431\u043e\u043b\u0435\u0435 \u0436\u0435\u0441\u0442\u043a\u0438\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>TRV-\u0441\u043a\u0440\u0438\u043d\u0438\u043d\u0433 \u0440\u0438\u0441\u043a\u043e\u0432 (\u0431\u044b\u0441\u0442\u0440\u044b\u0439):<\/strong> \u0415\u0441\u043b\u0438 \u201c\u0434\u0430\u201d \u043d\u0430 \u0432\u043e\u043f\u0440\u043e\u0441 <strong>2+<\/strong>, TRV \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u044f\u0432\u043d\u044b\u043c \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u043e\u043c \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438:<br>1) \u0434\u043b\u0438\u043d\u043d\u044b\u0435 \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u043b\u0438\u043d\u0438\u0438 MV<br>2) \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 (\u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0447\u0430\u0441\u0442\u043e\u0435\/\u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435)<br>3) \u0447\u0430\u0441\u0442\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\/\u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430<br>4) \u0441\u043c\u0435\u0448\u0430\u043d\u043d\u044b\u0435 \u043d\u0430\u043a\u043b\u0430\u0434\u043d\u044b\u0435 \u0440\u0430\u0441\u0445\u043e\u0434\u044b + \u0434\u043b\u0438\u043d\u043d\u0430\u044f \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u0430\u044f \u0441\u0435\u0442\u044c \/ \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0441 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u043e\u043c<br>5) \u043f\u0435\u0440\u0435\u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0441\u0442\u043e\u0440\u0438\u0438 \u0438\u043b\u0438 \u043d\u0435\u043e\u0431\u044a\u044f\u0441\u043d\u0438\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u043a\u043e\u043d\u0442\u0435\u043a\u0441\u0442\u0430 \u0444\u0438\u0437\u0438\u043a\u0438 \u0434\u0443\u0433\u0438 \u0441\u043c.:<br><a href=\"https:\/\/xbrele.com\/ru\/what-is-a-vacuum-interrupter\/\">\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c (VI) \u0438 \u043a\u0430\u043a \u043e\u043d \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442?<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-trv-envelope-figure-03.webp\" alt=\"\u041a\u043e\u043d\u0446\u0435\u043f\u0442\u0443\u0430\u043b\u044c\u043d\u0430\u044f \u043a\u0440\u0438\u0432\u0430\u044f \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043a\u0440\u0443\u0442\u043e\u0439 \u043f\u0438\u043a \u0440\u043e\u0441\u0442\u0430 \u0438 \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u0435\" class=\"wp-image-2272\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-trv-envelope-figure-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-trv-envelope-figure-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-trv-envelope-figure-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-trv-envelope-figure-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 3. \u041a\u043e\u043d\u0446\u0435\u043f\u0442\u0443\u0430\u043b\u044c\u043d\u0430\u044f \u043a\u0440\u0438\u0432\u0430\u044f TRV \u2014 \u043a\u0440\u0443\u0442\u043e\u0439 \u043f\u043e\u0434\u044a\u0435\u043c (RRRV) \u0438 \u043f\u0438\u043a\u043e\u0432\u043e\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u043c\u043e\u0433\u0430\u044e\u0442 \u043e\u0431\u044a\u044f\u0441\u043d\u0438\u0442\u044c \u0440\u0438\u0441\u043a \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0443\u0434\u0430\u0440\u0430 \u0432 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u0445 \u0441\u0435\u0442\u044f\u0445.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quick-comparison-table-what-each-rating-prevents\">\u0422\u0430\u0431\u043b\u0438\u0446\u0430 \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044f (\u0447\u0442\u043e \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043a\u0430\u0436\u0434\u044b\u0439 \u0440\u0435\u0439\u0442\u0438\u043d\u0433)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0420\u0435\u0439\u0442\u0438\u043d\u0433<\/th><th>\u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442<\/th><th>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0439 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u044b\u0431\u043e\u0440\u0430<\/th><\/tr><\/thead><tbody><tr><td>\u043a\u0412 \/ Ur<\/td><td>\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0447\u0435\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438<\/td><td>PD, \u043f\u0435\u0440\u0435\u0445\u043e\u0434 \u043f\u043b\u0430\u043c\u0435\u043d\u0438<\/td><\/tr><tr><td>A \/ Ir<\/td><td>\u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438<\/td><td>\u0433\u043e\u0440\u044f\u0447\u0438\u0435 \u0442\u043e\u0447\u043a\u0438, \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u043d\u044b\u0439 \u0438\u0437\u043d\u043e\u0441<\/td><\/tr><tr><td>\u043a\u0410 \/ Isc<\/td><td>\u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/td><td>\u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u0439 \u0443\u0449\u0435\u0440\u0431\/\u0441\u0431\u043e\u0439<\/td><\/tr><tr><td>Icw<\/td><td>\u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043f\u0440\u0438 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0435 \u043e\u0447\u0438\u0441\u0442\u043a\u0438<\/td><td>\u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0435\u0437\u0434\u043a\u043e\u0439 \/ \u043f\u043e\u0442\u0435\u0440\u044f \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438<\/td><\/tr><tr><td>\u0418\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \/ \u0437\u0430\u043a\u0440\u044b\u0442\u044b\u0439 \u0437\u0430\u043c\u043e\u043a<\/td><td>\u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u0441\u0438\u043b\u044b \u043f\u0440\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043d\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435<\/td><td>\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435\/\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435<\/td><\/tr><tr><td>BIL \/ LIWV<\/td><td>\u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u0430\u044f \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/td><td>\u043f\u0440\u043e\u0431\u043e\u0439 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438\/\u0441\u043a\u0440\u044b\u0442\u0430\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c<\/td><\/tr><tr><td>TRV<\/td><td>\u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0439 \u0441\u0442\u0440\u0435\u0441\u0441 \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f<\/td><td>\u043f\u043e\u0432\u0442\u043e\u0440\u043d\u044b\u0439 \u0443\u0434\u0430\u0440, \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-to-read-a-vcb-nameplate\">\u041a\u0430\u043a \u0447\u0438\u0442\u0430\u0442\u044c \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0443 \u0441 \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435\u043c VCB<\/h2>\n\n\n\n<p>\u0417\u0434\u0435\u0441\u044c \u043c\u044b \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u043c\u0441\u044f \u043a\u0440\u0430\u0442\u043a\u0438\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0435\u043c (\u043f\u043e\u043b\u043d\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043a\u0430\u0436\u0434\u043e\u043c\u0443 \u043f\u043e\u043b\u044e \u043c\u043e\u0436\u0435\u0442 \u0441\u0442\u0430\u0442\u044c \u0442\u0435\u043c\u043e\u0439 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0434\u043b\u0438\u043d\u043d\u043e\u0433\u043e \u043f\u043e\u0441\u0442\u0430 \u0432 \u0431\u0443\u0434\u0443\u0449\u0435\u043c).<\/p>\n\n\n\n<p><strong>\u0428\u0430\u0433 1 \u2014 \u041a\u043b\u0430\u0441\u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (Ur\/\u043a\u0412):<\/strong> \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u043a\u043b\u0430\u0441\u0441\u0443 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f.<br><strong>\u0428\u0430\u0433 2 \u2014 BIL\/LIWV (\u043a\u0412\u043f):<\/strong> \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c, \u0447\u0442\u043e \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u0430\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u043c \u043f\u043e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438.<br><strong>\u0428\u0430\u0433 3 \u2014 Ir (A):<\/strong> \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u044b\u0439 \u0442\u043e\u043a \u0441 \u0437\u0430\u043f\u0430\u0441\u043e\u043c \u0434\u043b\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b\/\u043a\u043e\u0440\u043f\u0443\u0441\u0430\/\u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u0446\u0438\u043a\u043b\u0430.<br><strong>\u0428\u0430\u0433 4 \u2014 \u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 (\u043a\u0410):<\/strong> \u0443\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u0442\u043e\u043a \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438.<br><strong>\u0428\u0430\u0433 5 \u2014 Icw (1s\/3s):<\/strong> \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c, \u0447\u0442\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u044b\u0434\u0435\u0440\u0436\u043a\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u043c \u043f\u043e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u043a\u043b\u0438\u0440\u0438\u043d\u0433\u0430.<br><strong>\u0428\u0430\u0433 6 \u2014 \u0418\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435 \u0438 \u0444\u0438\u043a\u0441\u0430\u0446\u0438\u044f (\u043f\u0440\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438):<\/strong> \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0441\u0431\u043e\u044f\u043c \u043f\u0440\u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0438, \u0435\u0441\u043b\u0438 \u044d\u0442\u043e \u0443\u043a\u0430\u0437\u0430\u043d\u043e.<br><strong>\u0428\u0430\u0433 7 \u2014 \u0424\u043b\u0430\u0433 TRV:<\/strong> \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435\u0439\/\u043a\u043e\u043b\u043f\u0430\u0447\u043a\u043e\u0432\/\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432, \u0443\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c \u0432 \u043f\u0440\u0438\u0433\u043e\u0434\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\/TRV.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-workflow\">\u0420\u0430\u0431\u043e\u0447\u0438\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u043e\u0442\u0431\u043e\u0440\u0430<\/h2>\n\n\n\n<p><em>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u00ab\u0421\u043d\u0430\u0447\u0430\u043b\u0430 \u0438\u0437\u0443\u0447\u0430\u0439\u00bb, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043f\u0440\u0438 \u0437\u0430\u0449\u0438\u0442\u0435 \u0432 \u0445\u043e\u0434\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/em><\/p>\n\n\n\n<p>1) \u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043a\u043b\u0430\u0441\u0441 \u043a\u0412 + BIL (\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438)<br>2) \u0420\u0430\u0437\u043c\u0435\u0440 Ir \u0441 \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u043c \u0437\u0430\u043f\u0430\u0441\u043e\u043c<br>3) \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432 \u0442\u043e\u0447\u043a\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438: kA + Icw + \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\/\u0437\u0430\u043f\u043e\u0440 (\u043f\u043e \u043c\u0435\u0440\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438)<br>4) \u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0440\u0430\u0431\u043e\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u0438 TRV\/\u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435\u0439\/\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432\/\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432<br>5) \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0440\u0430\u0431\u043e\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c\/\u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c, \u0435\u0441\u043b\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0447\u0430\u0441\u0442\u043e.<\/p>\n\n\n\n<p>\u0414\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0435\u043a\u0441\u0442\u043d\u044b\u0435 \u0441\u0441\u044b\u043b\u043a\u0438:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u0440\u0438\u043c\u0435\u0440 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0433\u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430: <a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c VS1<\/a><\/li>\n\n\n\n<li>\u041f\u0440\u0438\u043c\u0435\u0440 \u043a\u043e\u0440\u043c\u0443\u0448\u043a\u0438 \u0434\u043b\u044f \u0443\u043b\u0438\u0446\u044b: <a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/zw32-vacuum-circuit-breaker\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c ZW32<\/a><\/li>\n\n\n\n<li>\u041a\u043e\u043d\u0442\u0435\u043a\u0441\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u044f: <a href=\"https:\/\/xbrele.com\/ru\/what-is-auto-recloser-how-it-works-keeps-lights-on\/\">\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u043a\u043b\u043e\u0443\u0437\u0435\u0440 \u0438 \u043a\u0430\u043a \u043e\u043d \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u0435\u0441\u043f\u0435\u0440\u0435\u0431\u043e\u0439\u043d\u043e\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435?<\/a><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-application-map-figure-04.webp\" alt=\"\u041a\u0430\u0440\u0442\u0430 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f, \u0441\u0432\u044f\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0438 VCB \u0441 \u0441\u0446\u0435\u043d\u0430\u0440\u0438\u044f\u043c\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u043d\u0430\u0440\u0443\u0436\u043d\u044b\u0445 \u0444\u0438\u0434\u0435\u0440\u043e\u0432 \u0438 \u0440\u0435\u043a\u043b\u043e\u0443\u0437\u0435\u0440\u043e\u0432\" class=\"wp-image-2273\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-application-map-figure-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-application-map-figure-04-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-application-map-figure-04-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele-vcb-ratings-application-map-figure-04-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 4. \u041a\u0430\u0440\u0442\u0430 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u2014 \u043a\u0430\u043a \u043c\u0435\u043d\u044f\u044e\u0442\u0441\u044f \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442\u044b \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0430 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0441\u043b\u0443\u0447\u0430\u0435\u0432 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u043d\u0430\u0440\u0443\u0436\u043d\u044b\u0445 \u0444\u0438\u0434\u0435\u0440\u043e\u0432 \u0438 \u0440\u0435\u043a\u043b\u043e\u0443\u0437\u0435\u0440\u043e\u0432\/\u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u043a\u0438.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"worked-example-realistic-review-ready\">\u0420\u0430\u0431\u043e\u0447\u0438\u0439 \u043f\u0440\u0438\u043c\u0435\u0440 (\u0440\u0435\u0430\u043b\u0438\u0441\u0442\u0438\u0447\u043d\u044b\u0439, \u0433\u043e\u0442\u043e\u0432\u044b\u0439 \u043a \u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u0438\u044e)<\/h2>\n\n\n\n<p><strong>\u0421\u0438\u0441\u0442\u0435\u043c\u0430:<\/strong> \u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043d\u0430 \u0441\u0442\u0430\u043d\u0446\u0438\u0438 11 \u043a\u0412 (\u043e\u0431\u044b\u0447\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u043b\u0430\u0441\u0441\u0430 12 \u043a\u0412)<br><strong>\u041d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430:<\/strong> 980 \u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0439 \u2192 \u0432\u044b\u0431\u0440\u0430\u0442\u044c <strong>1250 \u0410<\/strong> \u0434\u043b\u044f \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0433\u043e \u0437\u0430\u043f\u0430\u0441\u0430<br><strong>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0432 \u043c\u0435\u0441\u0442\u0435 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f:<\/strong> 26 \u043a\u0410 \u0441\u0438\u043c\u043f\u043b RMS \u2192 \u0432\u044b\u0431\u0440\u0430\u0442\u044c <strong>31,5 \u043a\u0410<\/strong> \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0449\u0438\u0439<br><strong>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f:<\/strong> \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u0430 \u043d\u0430\u043c\u0435\u0440\u0435\u043d\u043d\u0430\u044f \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u043e\u043a\u043e\u043b\u043e 1 \u0441 \u2192 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c <strong>Icw<\/strong> \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0442\u0440\u0435\u0431\u0443\u0435\u043c\u043e\u0439 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438<br><strong>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f:<\/strong> \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0441\u043e\u0432\u043f\u0430\u0434\u0435\u043d\u0438\u0435 <strong>BIL<\/strong> \u0438 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043e\u0431 \u0430\u0440\u0435\u0441\u0442\u0435<br><strong>\u0421\u0435\u0442\u044c:<\/strong> \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430 + \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0435\u043c\u044b\u0439 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0439 \u0431\u043b\u043e\u043a \u2192 \u0441\u0438\u0433\u043d\u0430\u043b \u0440\u0438\u0441\u043a\u0430 TRV \u2192 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0440\u0430\u0431\u043e\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\/\u043f\u0440\u0438\u0433\u043e\u0434\u043d\u043e\u0441\u0442\u0438 TRV<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-mistakes-what-shows-up-in-real-reviews\">\u0420\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 (\u0447\u0442\u043e \u0432\u0441\u0442\u0440\u0435\u0447\u0430\u0435\u0442\u0441\u044f \u0432 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043e\u0442\u0437\u044b\u0432\u0430\u0445)<\/h2>\n\n\n\n<p>1) \u0432\u044b\u0431\u043e\u0440 \u043f\u043e \u043f\u0440\u043e\u0437\u0432\u0438\u0449\u0443 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u044f \u0432\u043c\u0435\u0441\u0442\u043e \u043a\u043b\u0430\u0441\u0441\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f + \u0443\u0440\u043e\u0432\u043d\u0435\u0439 \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u0438<br>2) \u0440\u0430\u0431\u043e\u0442\u0430 \u0441 Ir \u043d\u0430 \u043a\u0440\u0430\u044e \u0432 \u0436\u0430\u0440\u043a\u0438\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f\u0445 \u0438\u043b\u0438 \u0442\u0435\u0441\u043d\u044b\u0445 \u043a\u0430\u0431\u0438\u043d\u0430\u0445<br>3) \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u043e\u0432\u0441\u0435\u043c\u0435\u0441\u0442\u043d\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0448\u0438\u043d\u044b \u0432\u043c\u0435\u0441\u0442\u043e \u0442\u043e\u043a\u0430 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438, \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u043d\u043e\u0433\u043e \u0434\u043b\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u043e\u0433\u043e \u043c\u0435\u0441\u0442\u0430<br>4) \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 Icw, \u0430 \u0437\u0430\u0442\u0435\u043c \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0435, \u0447\u0442\u043e \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043d\u0435 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439<br>5) \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u043a BIL \u043a\u0430\u043a \u043a \u0444\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u0438, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0430\u0440\u0435\u0441\u0442\u043e\u0432\u0430\u0432\u0448\u0438\u0445\u0441\u044f \u0440\u0430\u0437\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f<br>6) \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 TRV \u0432 \u0441\u0435\u0442\u044f\u0445 \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435\u0439\/\u043a\u0440\u044b\u0448\u0435\u043a, \u0430 \u0437\u0430\u0442\u0435\u043c \u043f\u043e\u0438\u0441\u043a \u0441\u0438\u043c\u043f\u0442\u043e\u043c\u043e\u0432 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/p>\n\n\n\n<p>\u0415\u0441\u043b\u0438 \u0432\u044b \u043d\u0435 \u0443\u0432\u0435\u0440\u0435\u043d\u044b, \u043d\u0443\u0436\u0435\u043d \u043b\u0438 \u0432\u0430\u043c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0438\u043b\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440, \u043f\u0440\u043e\u0447\u0442\u0438\u0442\u0435:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ru\/difference-between-vcb-and-contactor-in-electrical-systems\/\">\u0420\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 VCB \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u043c<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor-vs-vacuum-circuit-breaker-medium-voltage-panel\/\">\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043f\u0440\u043e\u0442\u0438\u0432 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f (\u0432\u044b\u0431\u043e\u0440 \u043f\u0430\u043d\u0435\u043b\u0438)<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"micro-q-a-long-tail-coverage\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n\n\n\n<p><strong>\u041f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u043b\u0438 \u043a\u043b\u0430\u0441\u0441 12 \u043a\u0412 \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b 11 \u043a\u0412?<\/strong><br>\u0427\u0430\u0441\u0442\u043e \u0434\u0430. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043a\u043b\u0430\u0441\u0441 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435, \u0430 \u043d\u0435 \u043f\u0440\u043e\u0437\u0432\u0438\u0449\u0435 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u044f.<\/p>\n\n\n\n<p><strong>\u0412 \u0447\u0435\u043c \u0440\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435\u043c kA \u0438 Icw?<\/strong><br>kA \u2014 \u044d\u0442\u043e \u0442\u043e, \u0447\u0442\u043e \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c; Icw \u2014 \u044d\u0442\u043e \u0442\u043e, \u0447\u0442\u043e \u043e\u043d \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0434\u0435\u0440\u0436\u0430\u0442\u044c \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<p><strong>\u0427\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u201c\u0437\u0430\u043a\u0440\u044b\u0442\u044c \u0438 \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u0442\u044c\u201d?<\/strong><br>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0431\u043b\u0438\u0437\u043a\u043e\u043c\u0443 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044e \u043a \u0440\u0430\u0437\u043b\u043e\u043c\u0443: \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c.<\/p>\n\n\n\n<p><strong>\u041c\u043e\u0436\u0435\u0442 \u043b\u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c\u0443 \u0442\u043e\u043a\u0443 \u0432 \u043a\u0410, \u043d\u043e \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u0432\u0441\u0435 \u0440\u0430\u0432\u043d\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0442\u044c \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e?<\/strong><br>\u0414\u0430. TRV\/RRRV \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0437\u0430\u0436\u0438\u0433\u0430\u043d\u0438\u0435 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e\u043c \u043a\u0430\u0431\u0435\u043b\u0435\u0439\/\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"standards-references-authority\">\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0438 \u0441\u0441\u044b\u043b\u043a\u0438 (\u0430\u0432\u0442\u043e\u0440\u0438\u0442\u0435\u0442\u043d\u044b\u0435 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438)<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IEC 62271-100 (\u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430): <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"noopener\">https:\/\/webstore.iec.ch\/en\/publication\/62785<\/a><\/li>\n\n\n\n<li>IEEE C37.04 (\u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0438 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f): <a href=\"https:\/\/standards.ieee.org\/ieee\/C37.04\/5357\/\" target=\"_blank\" rel=\"noopener\">https:\/\/standards.ieee.org\/ieee\/C37.04\/5357\/<\/a><\/li>\n\n\n\n<li>IEEE C37.09 (\u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f): <a href=\"https:\/\/standards.ieee.org\/ieee\/C37.09\/5676\/\" target=\"_blank\" rel=\"noopener\">https:\/\/standards.ieee.org\/ieee\/C37.09\/5676\/<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"revision-log\">\u0416\u0443\u0440\u043d\u0430\u043b \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0439<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>22.12.2025: \u0420\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u043e \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u043e \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439 (kA + Icw + \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\/\u0437\u0430\u043f\u043e\u0440), \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d TRV-\u0441\u043a\u0440\u0438\u043d\u0435\u0440, \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u0430 \u0442\u0430\u0431\u043b\u0438\u0446\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0439 IEC \u0438 IEEE, \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d\u044b \u0433\u043b\u043e\u0441\u0441\u0430\u0440\u0438\u0439 \u0438 \u043c\u0438\u043a\u0440\u043e-\u0432\u043e\u043f\u0440\u043e\u0441\u044b \u0438 \u043e\u0442\u0432\u0435\u0442\u044b, \u0434\u043e\u0431\u0430\u0432\u043b\u0435\u043d \u043f\u043b\u0430\u043d \u0441 \u0440\u0438\u0441\u0443\u043d\u043a\u0430\u043c\u0438 (4 \u0440\u0438\u0441\u0443\u043d\u043a\u0430 + \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0438).<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u0420\u0430\u0441\u0448\u0438\u0444\u0440\u0443\u0439\u0442\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u043a\u043b\u0430\u0441\u0441 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0442\u043e\u043a \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f, BIL, \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0443\u044e \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c \u0438 \u0440\u0430\u0431\u043e\u0447\u0438\u0439 \u0446\u0438\u043a\u043b \u0434\u043e \u043f\u043e\u0434\u0430\u0447\u0438 \u0437\u0430\u043f\u0440\u043e\u0441\u0430 \u043d\u0430 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0443.<\/p>","protected":false},"author":3,"featured_media":2274,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2269","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2269"}],"version-history":[{"count":6,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2269\/revisions"}],"predecessor-version":[{"id":3845,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2269\/revisions\/3845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2274"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2269"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2269"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}