{"id":2386,"date":"2025-12-31T12:52:57","date_gmt":"2025-12-31T12:52:57","guid":{"rendered":"https:\/\/xbrele.com\/?p=2386"},"modified":"2026-05-25T15:17:45","modified_gmt":"2026-05-25T15:17:45","slug":"top-10-vacuum-contactor-manufacturers-guide","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/top-10-vacuum-contactor-manufacturers-guide\/","title":{"rendered":"10 \u0432\u0435\u0434\u0443\u0449\u0438\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 (\u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c + \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c + OEM-\u0432\u0435\u0434\u0440\u0430)"},"content":{"rendered":"\ufeff\n<p>\u0412\u044b\u0431\u043e\u0440 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u2014 \u044d\u0442\u043e \u043d\u0435 \u043f\u0440\u043e\u0441\u0442\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e \u043f\u043e\u043a\u0443\u043f\u043a\u0435 \u0442\u043e\u0432\u0430\u0440\u0430. \u0414\u0432\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c 12 \u043a\u0412, 400 \u0410, AC-4 \u043c\u043e\u0433\u0443\u0442 \u0440\u0430\u0437\u043b\u0438\u0447\u0430\u0442\u044c\u0441\u044f \u043f\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u0441\u0440\u043e\u043a\u0443 \u0441\u043b\u0443\u0436\u0431\u044b \u0432 \u0442\u0440\u0438 \u0440\u0430\u0437\u0430, \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0440\u0430\u0437\u043d\u044b\u0435 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 \u044d\u0440\u043e\u0437\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (40%) \u0438 \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0442\u044c\u0441\u044f \u0441 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0435\u0439, \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u043e\u0442 \u201c\u043f\u043e\u043b\u043d\u044b\u0445 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0432 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439\u201d \u0434\u043e \u201c\u0434\u043e\u0432\u0435\u0440\u044c\u0442\u0435\u0441\u044c \u043d\u0430\u043c, \u044d\u0442\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442\u201d. \u042d\u0442\u0438 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f \u043f\u0440\u043e\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0447\u0435\u0440\u0435\u0437 18 \u043c\u0435\u0441\u044f\u0446\u0435\u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u2014 \u043f\u043e\u0441\u043b\u0435 \u0432\u0432\u043e\u0434\u0430 \u043f\u0430\u043d\u0435\u043b\u0438 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e, \u043f\u043e\u0441\u043b\u0435 \u043e\u043a\u043e\u043d\u0447\u0430\u043d\u0438\u044f \u0441\u0440\u043e\u043a\u0430 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0438 OEM \u0438 \u043f\u043e\u0441\u043b\u0435 \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u0437\u0430\u043c\u0435\u043d\u0430 \u0434\u0435\u0442\u0430\u043b\u0435\u0439 \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u043e\u0439 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f.<\/p>\n\n\n\n<p>\u0420\u044b\u043d\u043e\u043a \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0434\u0435\u043b\u0438\u0442\u0441\u044f \u043d\u0430 \u0442\u0440\u0438 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0430: \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0435 \u0431\u0440\u0435\u043d\u0434\u044b \u0443\u0440\u043e\u0432\u043d\u044f 1 \u0441 \u043f\u0440\u0435\u043c\u0438\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0446\u0435\u043d\u0430\u043c\u0438 \u0438 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u043e\u0439 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u043e\u0439, \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438, \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u044b\u0435 \u0446\u0435\u043d\u044b \u0441 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430, \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u0438 OEM, \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0441 \u0431\u043e\u043b\u044c\u0448\u0438\u043c\u0438 \u043e\u0431\u044a\u0435\u043c\u0430\u043c\u0438. \u041a\u0430\u0436\u0434\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u0443\u0434\u043e\u0432\u043b\u0435\u0442\u0432\u043e\u0440\u044f\u0435\u0442 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u0438 \u043f\u043e\u043a\u0443\u043f\u0430\u0442\u0435\u043b\u0435\u0439, \u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0435\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0434\u043e\u043b\u0433\u043e\u0441\u0440\u043e\u0447\u043d\u0443\u044e \u0440\u0435\u043d\u0442\u0430\u0431\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0432 \u0431\u043e\u043b\u044c\u0448\u0435\u0439 \u0441\u0442\u0435\u043f\u0435\u043d\u0438, \u0447\u0435\u043c \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u043a\u0443\u043f\u043d\u0430\u044f \u0446\u0435\u043d\u0430.<\/p>\n\n\n\n<p>\u0412 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u0434\u0430\u043d\u0430 \u043e\u0446\u0435\u043d\u043a\u0430 10 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043f\u043e \u0447\u0435\u0442\u044b\u0440\u0435\u043c \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044f\u043c: \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c, \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0438 \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u043d\u0430 \u043c\u0435\u0441\u0442\u0435. \u0412 \u0430\u043d\u0430\u043b\u0438\u0437\u0435 \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442 \u043e\u0442\u0434\u0430\u0435\u0442\u0441\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044e \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438 (\u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c, \u0432\u043e\u0434\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435\/\u0432\u043e\u0434\u043e\u043e\u0442\u0432\u0435\u0434\u0435\u043d\u0438\u0435, HVAC) \u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 OEM, \u0430 \u043d\u0435 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u043c, \u0433\u0434\u0435 \u043f\u0440\u0435\u043e\u0431\u043b\u0430\u0434\u0430\u044e\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-contactor-manufacturer-comparison-matrix\">\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043c\u0430\u0442\u0440\u0438\u0446\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0422\u0438\u043f \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u0430<\/th><th>\u041f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/th><th>\u041d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/th><th>\u041f\u043e\u043a\u0443\u043f\u0430\u0442\u0435\u043b\u044c \u0440\u0438\u0441\u043a\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c<\/th><\/tr><\/thead><tbody><tr><td>\u0413\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0439 \u0431\u0440\u0435\u043d\u0434 \u043f\u0440\u0435\u043c\u0438\u0443\u043c-\u043a\u043b\u0430\u0441\u0441\u0430<\/td><td>\u0428\u0438\u0440\u043e\u043a\u0430\u044f \u0431\u0430\u0437\u0430 \u0438\u043d\u0441\u0442\u0430\u043b\u043b\u044f\u0446\u0438\u0439, \u0433\u043e\u0442\u043e\u0432\u0430\u044f \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f, \u0440\u0430\u0437\u0432\u0438\u0442\u0430\u044f \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u0430\u044f \u0441\u0435\u0442\u044c.<\/td><td>\u0412\u0430\u0436\u043d\u0435\u0439\u0448\u0438\u0435 \u0444\u0438\u0434\u0435\u0440\u044b \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439, \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u044b\u0435 \u0441\u0435\u0442\u0438 \u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u044b, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0435 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f.<\/td><td>\u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0446\u0435\u043d\u0430, \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u0438 \u043c\u0435\u043d\u044c\u0448\u0430\u044f \u0433\u0438\u0431\u043a\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u043d\u0435\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u0439 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438.<\/td><\/tr><tr><td>\u0421\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442 \u043f\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0443 MV, \u0442\u0430\u043a\u043e\u0439 \u043a\u0430\u043a XBRELE<\/td><td>\u0418\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u0430\u044f \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430, \u0430\u043d\u0430\u043b\u0438\u0437 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 \u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u0437\u0430\u043a\u0430\u0437\u0430.<\/td><td>OEM-\u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u0433\u043e\u0440\u043d\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c, \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432, \u0440\u0430\u0431\u043e\u0442\u0430 \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u044b \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438.<\/td><td>\u041f\u0435\u0440\u0435\u0434 \u0437\u0430\u043a\u0430\u0437\u043e\u043c \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a, \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438 \u043f\u043b\u0430\u043d \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439.<\/td><\/tr><tr><td>\u041f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a \u043d\u0435\u0434\u043e\u0440\u043e\u0433\u0438\u0445 \u0442\u043e\u0432\u0430\u0440\u043e\u0432<\/td><td>\u041a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u0430\u044f \u0446\u0435\u043d\u0430 \u0437\u0430 \u0435\u0434\u0438\u043d\u0438\u0446\u0443 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438 \u0434\u043b\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u0439 \u0437\u0430\u043c\u0435\u043d\u044b.<\/td><td>\u041d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0441 \u0447\u0435\u0442\u043a\u0438\u043c\u0438 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u043c\u0438 \u0438 \u043c\u0435\u0441\u0442\u043d\u043e\u0439 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u044d\u043a\u0441\u043f\u0435\u0440\u0442\u0438\u0437\u043e\u0439.<\/td><td>\u0413\u043b\u0443\u0431\u0438\u043d\u0430 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438, \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u0438, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438 \u043f\u043e\u0441\u043b\u0435\u043f\u0440\u043e\u0434\u0430\u0436\u043d\u0430\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"when-to-choose-xbrele-for-vacuum-contactor-projects\">\u041a\u043e\u0433\u0434\u0430 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0432\u044b\u0431\u0438\u0440\u0430\u0442\u044c XBRELE \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n\n\n\n<p>\u0412\u044b\u0431\u0438\u0440\u0430\u0439\u0442\u0435 XBRELE, \u043a\u043e\u0433\u0434\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439: \u043f\u0443\u0441\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438, \u0448\u0430\u0445\u0442\u043d\u044b\u0435 \u0444\u0438\u0434\u0435\u0440\u044b, \u0432\u044b\u0441\u043e\u0442\u043d\u044b\u0435 \u043f\u0430\u043d\u0435\u043b\u0438 \u0438\u043b\u0438 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u0437\u0430\u043c\u0435\u043d\u0430. \u0426\u0435\u043b\u044c - \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430, \u043d\u043e \u0438 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u0438\u0435 \u0441 \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0435\u0439.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-contactor-rfq-checklist\">\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a RFQ \u0434\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a, \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f, \u0440\u0430\u0431\u043e\u0447\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0438 \u043e\u0436\u0438\u0434\u0430\u0435\u043c\u044b\u0435 \u0437\u0430\u043f\u0443\u0441\u043a\u0438 \u0432 \u0447\u0430\u0441.<\/li><li>\u0422\u0438\u043f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438: \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044c, \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440, \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0430\u044f \u0431\u0430\u0442\u0430\u0440\u0435\u044f, \u0440\u0435\u0430\u043a\u0442\u043e\u0440, \u0448\u0430\u0445\u0442\u043d\u044b\u0439 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u044c \u0438\u043b\u0438 \u043e\u0431\u0449\u0435\u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0439 \u043f\u0438\u0442\u0430\u0442\u0435\u043b\u044c.<\/li><li>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c, \u0442\u0438\u043f \u0437\u0430\u0449\u0435\u043b\u043a\u0438, \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439 \u0438 \u043b\u043e\u0433\u0438\u043a\u0430 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043f\u0430\u043d\u0435\u043b\u0438.<\/li><li>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441, \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441, \u043d\u043e\u043c\u0438\u043d\u0430\u043b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0438\u0437\u043d\u043e\u0441\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432.<\/li><li>\u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u044b\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b, \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0447\u0435\u0440\u0442\u0435\u0436\u0438, \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u0447\u0430\u0441\u0442\u0438, \u0446\u0435\u043b\u0435\u0432\u043e\u0439 \u0446\u0435\u043d\u043e\u0432\u043e\u0439 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0438 \u0432\u0440\u0435\u043c\u044f \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u0437\u0430\u043a\u0430\u0437\u0430.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-manufacturer-selection-determines-total-cost-of-ownership\">\u041f\u043e\u0447\u0435\u043c\u0443 \u0432\u044b\u0431\u043e\u0440 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043e\u0431\u0449\u0443\u044e \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u043b\u0430\u0434\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<p>\u0421\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u0434\u0432\u0443\u0445 \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u044b\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u0432 \u0438\u0437\u043d\u043e\u0441\u0430: \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0446\u0438\u043a\u043b\u044b \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f\/\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f) \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0441\u043e\u0437\u0434\u0430\u043d\u0438\u0435\/\u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0442\u043e\u043a\u0430 \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439). \u0414\u0435\u0448\u0435\u0432\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432\u044b\u0445\u043e\u0434\u044f\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u043f\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0447\u0430\u0441\u0442\u0438 - \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0443\u0441\u0442\u0430\u044e\u0442, \u0442\u044f\u0433\u0438 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u044e\u0442\u0441\u044f, \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0437\u0430\u043a\u043b\u0438\u043d\u0438\u0432\u0430\u0435\u0442 \u043f\u043e\u0441\u043b\u0435 50 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432\u043c\u0435\u0441\u0442\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e 1 \u043c\u0438\u043b\u043b\u0438\u043e\u043d\u0430. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u043c\u0438\u0443\u043c-\u043a\u043b\u0430\u0441\u0441\u0430 \u0432\u044b\u0445\u043e\u0434\u044f\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u043f\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u0440\u0435\u0441\u0443\u0440\u0441\u0443 - \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u043f\u0440\u0435\u0434\u0441\u043a\u0430\u0437\u0443\u0435\u043c\u043e, \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u044f \u043a\u043e\u043d\u0446\u0430 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u043f\u043e\u0441\u043b\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0446\u0438\u043a\u043b\u043e\u0432 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0430 \u043d\u0435 \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u044b\u0445 \u043e\u0442\u043a\u0430\u0437\u043e\u0432. \u041f\u0440\u0438 \u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0441\u043e\u0433\u043b\u0430\u0441\u0443\u0439\u0442\u0435 \u044d\u0442\u043e \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435 \u0441 <a href=\"https:\/\/xbrele.com\/ru\/mechanical-life-vs-electrical-life-contactor-endurance\/\">\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441<\/a>.<\/p>\n\n\n\n<p><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/strong>&nbsp;\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u0442 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u043e\u0439 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u0443\u0441\u043a\u0430\u0442\u0435\u043b\u0438 \u0446\u0435\u043d\u0442\u0440\u043e\u0431\u0435\u0436\u043d\u044b\u0445 \u043d\u0430\u0441\u043e\u0441\u043e\u0432: 200\u2013500 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0434\u0435\u043d\u044c<\/li>\n\n\n\n<li>\u041c\u044f\u0433\u043a\u0438\u0435 \u043f\u0443\u0441\u043a\u0430\u0442\u0435\u043b\u0438 HVAC: 10\u201350 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0434\u0435\u043d\u044c<\/li>\n\n\n\n<li>\u0413\u043e\u0440\u043d\u044b\u0435 \u043a\u043e\u043d\u0432\u0435\u0439\u0435\u0440\u044b: 100\u2013300 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0434\u0435\u043d\u044c<\/li>\n<\/ul>\n\n\n\n<p>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u00a0<strong>1 \u043c\u0438\u043b\u043b\u0438\u043e\u043d \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/strong>\u00a0\u0432 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0438 \u0441 200 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u043c\u0438 \u0432 \u0434\u0435\u043d\u044c \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043a\u0430\u0436\u0434\u044b\u0435\u00a0<strong>13,7 \u043b\u0435\u0442<\/strong>\u00a0(1 000 000 \/ 200 \/ 365). \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c 500 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043a\u0430\u0436\u0434\u044b\u0435\u00a0<strong>6,8 \u043b\u0435\u0442<\/strong>\u2014\u0443\u0434\u0432\u043e\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430.<\/p>\n\n\n\n<p><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0436\u0438\u0437\u043d\u044c<\/strong>&nbsp;\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u0442 \u0441\u0440\u043e\u043a\u0438 \u0437\u0430\u043c\u0435\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u041c\u042d\u041a 62271-106 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435 \u0434\u043b\u044f \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f AC-4 (\u043f\u0443\u0441\u043a\u043e\u0432\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430, \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a), \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u0438\u043d\u0442\u0435\u0440\u043f\u0440\u0435\u0442\u0430\u0446\u0438\u044f \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u0430 \u0441 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/74487\" target=\"_blank\" rel=\"noopener\">\u041c\u042d\u041a 60947-4-1<\/a>. \u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 150 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043f\u0435\u0440\u0432\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 8 000-12 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 AC-4, \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u0440\u0435\u0432\u044b\u0441\u0438\u0442 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u0435 \u043f\u0440\u0435\u0434\u0435\u043b\u044b, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u044f \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0432\u044b\u0445\u043e\u0434\u0438\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u043f\u0440\u0438 3 000-5 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u0445.<\/p>\n\n\n\n<p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/\">\u043e\u0441\u043d\u043e\u0432\u044b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430<\/a>&nbsp;\u0438&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\">\u043a\u0430\u043a \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0438 \u0433\u0430\u0441\u044f\u0442 \u0434\u0443\u0433\u0438<\/a>&nbsp;\u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u0443\u044e \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044e \u0434\u043b\u044f \u043e\u0446\u0435\u043d\u043a\u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01.webp\" alt=\"\u0422\u0440\u0435\u0445\u0443\u0440\u043e\u0432\u043d\u0435\u0432\u0430\u044f \u043f\u0438\u0440\u0430\u043c\u0438\u0434\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u044b \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u043e\u0432 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u0440\u0435\u043c\u0438\u0443\u043c-\u043a\u043b\u0430\u0441\u0441\u0430, \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0438 \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f.\" class=\"wp-image-2387\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0418\u0421. 01: \u0423\u0440\u043e\u0432\u043d\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043e\u0442\u0440\u0430\u0436\u0430\u044e\u0442 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u0446\u0435\u043d\u043d\u043e\u0441\u0442\u043d\u044b\u0435 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u044f: \u0443\u0440\u043e\u0432\u0435\u043d\u044c 1 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u0443\u044e \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0443 \u043f\u043e \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0446\u0435\u043d\u0435, \u0430 \u0443\u0440\u043e\u0432\u0435\u043d\u044c 3 \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u0437\u0430\u0442\u0440\u0430\u0442\u0430\u0445 \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-1-global-premium-manufacturers\">\u0423\u0440\u043e\u0432\u0435\u043d\u044c 1: \u041c\u0438\u0440\u043e\u0432\u044b\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043f\u0440\u0435\u043c\u0438\u0443\u043c-\u043a\u043b\u0430\u0441\u0441\u0430<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-abb-switzerlandsweden\">1. ABB (\u0428\u0432\u0435\u0439\u0446\u0430\u0440\u0438\u044f\/\u0428\u0432\u0435\u0446\u0438\u044f)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: VM1, VD4H (\u0433\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0439 VCB\/\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 3,6\u201340,5 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: \u0414\u043e 1 000 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043e \u043f\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEC 62271-106)<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 10 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435<\/p>\n\n\n\n<p>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b ABB \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u044b \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439, \u0433\u0434\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0441 \u043f\u0440\u043e\u0441\u0442\u043e\u044f\u043c\u0438, \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0442 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u0421\u0435\u0440\u0438\u044f VM1 \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0441 \u043f\u043e\u0437\u043e\u043b\u043e\u0447\u0435\u043d\u043d\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430\u043c\u0438 \u0438 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u0443\u044e \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u0443. \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u043f\u043e\u043b\u043d\u044b\u0435 \u043e\u0442\u0447\u0435\u0442\u044b \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445, \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u0445 KEMA (\u041d\u0438\u0434\u0435\u0440\u043b\u0430\u043d\u0434\u044b) \u0438 CPRI (\u0418\u043d\u0434\u0438\u044f).<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041d\u0430\u0438\u0431\u043e\u043b\u044c\u0448\u0430\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445 (\u043c\u044b \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043b\u0438 1,2 \u043c\u043b\u043d \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0434\u043e \u043f\u043e\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0430\u043b\u043e\u0441\u0442\u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0432 \u043c\u043e\u0440\u0441\u043a\u043e\u043c \u043d\u0430\u0441\u043e\u0441\u0435)<\/li>\n\n\n\n<li>\u0413\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u0430\u044f \u0441\u0435\u0442\u044c \u0441 \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u043e\u0439 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 48 \u0447\u0430\u0441\u043e\u0432 \u0432 \u0431\u043e\u043b\u0435\u0435 \u0447\u0435\u043c 80 \u0441\u0442\u0440\u0430\u043d\u0430\u0445<\/li>\n\n\n\n<li>\u041f\u043e\u043b\u043d\u044b\u0439 \u043d\u0430\u0431\u043e\u0440 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0432 IEC\/IEEE, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0441\u0435\u0439\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044e<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>25\u201340%: \u0446\u0435\u043d\u043e\u0432\u0430\u044f \u043d\u0430\u0434\u0431\u0430\u0432\u043a\u0430 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u043c\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f\u043c\u0438<\/li>\n\n\n\n<li>\u0421\u0440\u043e\u043a\u0438 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0438 12\u201316 \u043d\u0435\u0434\u0435\u043b\u044c \u0434\u043b\u044f \u043a\u0430\u0442\u0443\u0448\u0435\u043a \u0441 \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u044b\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c<\/li>\n\n\n\n<li>\u0418\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u043e\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u043d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u041e\u0412\u041a\u0412 \u0438\u043b\u0438 \u043c\u0430\u043b\u043e\u043c\u043e\u0449\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u0412\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0430\u0442\u043e\u043c\u043d\u044b\u0445 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u0441\u0443\u0434\u043e\u0432\u044b\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438, \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0435 \u0434\u043b\u044f \u043d\u0435\u0444\u0442\u0435\u0433\u0430\u0437\u043e\u0432\u043e\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-schneider-electric-france\">2. Schneider Electric (\u0424\u0440\u0430\u043d\u0446\u0438\u044f)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: \u0420\u0435\u043a\u043b\u043e\u0443\u0437\u0435\u0440-M, SM6 (\u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u0439 RMU)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 7,2\u201324 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 500 000\u20131 000 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 8000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u044f Schneider \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u0430 \u0432 \u044d\u043a\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u0443 EcoStruxure \u2014 \u043f\u0440\u043e\u0444\u0438\u043b\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0434\u0430\u0442\u0447\u0438\u043a\u043e\u0432 IIoT \u0438 \u043e\u0431\u043b\u0430\u0447\u043d\u043e\u0439 \u0430\u043d\u0430\u043b\u0438\u0442\u0438\u043a\u0438. \u041a\u043e\u043b\u044c\u0446\u0435\u0432\u043e\u0439 \u0433\u043b\u0430\u0432\u043d\u044b\u0439 \u0431\u043b\u043e\u043a SM6 \u043e\u0441\u043d\u0430\u0449\u0435\u043d \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438 \u0441 \u043f\u043b\u0430\u0432\u043a\u0438\u043c\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u043c\u0438, \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u044f \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0435 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0437\u043b\u044b, \u043f\u043e\u043f\u0443\u043b\u044f\u0440\u043d\u044b\u0435 \u0432 \u0435\u0432\u0440\u043e\u043f\u0435\u0439\u0441\u043a\u0438\u0445 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f\u0445.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u0438\u043b\u044c\u043d\u0430\u044f \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f SCADA\/\u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 (Modbus, IEC 61850)<\/li>\n\n\n\n<li>\u041a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u044b\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u044b \u043e\u0431\u0443\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0441\u0431\u043e\u0440\u0449\u0438\u043a\u043e\u0432 \u043f\u0430\u043d\u0435\u043b\u0435\u0439<\/li>\n\n\n\n<li>\u0413\u043e\u0442\u043e\u0432\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u044e\u0442 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u0430\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0430\u0432\u0442\u043e\u043d\u043e\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 (\u0432 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442\u0435 \u0441 RMU)<\/li>\n\n\n\n<li>\u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f\u043c\u0438 \u0447\u0438\u0441\u0442\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/li>\n\n\n\n<li>\u0421\u0435\u0442\u044c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043d\u0430 \u0415\u0432\u0440\u043e\u043f\u0443 (\u043c\u0435\u043d\u0435\u0435 \u0440\u0430\u0437\u0432\u0438\u0442\u0430\u044f \u0432 \u0410\u0437\u0438\u0430\u0442\u0441\u043a\u043e-\u0422\u0438\u0445\u043e\u043e\u043a\u0435\u0430\u043d\u0441\u043a\u043e\u043c \u0440\u0435\u0433\u0438\u043e\u043d\u0435)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041f\u0440\u043e\u0435\u043a\u0442\u044b \u043f\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044e \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439, \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438, \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u0443\u0433<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-eaton-usaireland\">3. Eaton (\u0421\u0428\u0410\/\u0418\u0440\u043b\u0430\u043d\u0434\u0438\u044f)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: VCP-W, Magnum DS (\u0441\u0440\u0435\u0434\u043d\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 4,16\u201315 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 600 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 6000\u20138000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>Eaton \u043d\u0430\u0446\u0435\u043b\u0435\u043d\u0430 \u043d\u0430 \u0441\u0435\u0432\u0435\u0440\u043e\u0430\u043c\u0435\u0440\u0438\u043a\u0430\u043d\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u0440\u044b\u043d\u043a\u0438 \u0441 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u0430\u043c\u0438 UL\/CSA \u0438 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u043c\u0438, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0438\u043c\u0438 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0440\u044f\u0434\u0430. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 VCP-W \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u043a \u0434\u0443\u0433\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u043c\u0443 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e \u0442\u0438\u043f\u0430 2B \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEEE C37.20.7, \u0447\u0442\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u043c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0434\u043b\u044f \u043d\u0435\u0444\u0442\u0435\u0433\u0430\u0437\u043e\u0432\u044b\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u043e\u0432.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041b\u0443\u0447\u0448\u0438\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0440\u044f\u0434\u0430 (\u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u0438, \u0441\u0431\u0440\u043e\u0441 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f)<\/li>\n\n\n\n<li>\u0421\u0438\u043b\u044c\u043d\u0430\u044f \u0434\u0438\u0441\u0442\u0440\u0438\u0431\u044c\u044e\u0442\u043e\u0440\u0441\u043a\u0430\u044f \u0441\u0435\u0442\u044c \u0432 \u0421\u0435\u0432\u0435\u0440\u043d\u043e\u0439 \u0410\u043c\u0435\u0440\u0438\u043a\u0435 (\u0431\u043e\u043b\u0435\u0435 30 \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u044b\u0445 \u0446\u0435\u043d\u0442\u0440\u043e\u0432)<\/li>\n\n\n\n<li>\u0412\u0437\u0430\u0438\u043c\u043e\u0437\u0430\u043c\u0435\u043d\u044f\u0435\u043c \u0441 \u0443\u0441\u0442\u0430\u0440\u0435\u0432\u0448\u0438\u043c\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438 Cutler-Hammer (\u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0435 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0437\u0430 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u043c\u0438 \u0421\u0435\u0432\u0435\u0440\u043d\u043e\u0439 \u0410\u043c\u0435\u0440\u0438\u043a\u0438<\/li>\n\n\n\n<li>\u041c\u0435\u043d\u044c\u0448\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u043b\u0430\u0441\u0441\u043e\u0432 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0447\u0435\u043c \u0443 \u0435\u0432\u0440\u043e\u043f\u0435\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 (\u0441\u043e\u0441\u0440\u0435\u0434\u043e\u0442\u043e\u0447\u0435\u043d\u043e \u043d\u0430 4,16 \u043a\u0412, 13,8 \u043a\u0412)<\/li>\n\n\n\n<li>\u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043d\u0430 \u0430\u0437\u0438\u0430\u0442\u0441\u043a\u0438\u0445 \u0440\u044b\u043d\u043a\u0430\u0445 \u0438\u0437-\u0437\u0430 \u0438\u043c\u043f\u043e\u0440\u0442\u043d\u044b\u0445 \u043f\u043e\u0448\u043b\u0438\u043d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f \u0421\u0428\u0410, \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c (\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c MSHA), \u043f\u0440\u043e\u0435\u043a\u0442\u044b \u043f\u043e \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0440\u044f\u0434\u0430<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-2-industrial-oem-specialists\">\u0423\u0440\u043e\u0432\u0435\u043d\u044c 2: \u0421\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u044b \u043f\u043e \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 OEM<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-xbrele-china\">4. XBRELE (\u041a\u0438\u0442\u0430\u0439)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: CKG3, CKG4 (\u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c), JCZ (\u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0443\u0433\u043e\u043b\u044c\u043d\u044b\u0445 \u0448\u0430\u0445\u0442\u0430\u0445)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 3,6\u201312 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 1 000 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u043a\u043b\u0430\u0441\u0441 M2 \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-106)<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 8000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>XBRELE \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043a\u0430\u043a&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor-vs-vacuum-circuit-breaker-medium-voltage-panel\/\">\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 OEM<\/a>&nbsp;\u0441 \u0431\u043e\u043b\u0435\u0435 \u0447\u0435\u043c 15-\u043b\u0435\u0442\u043d\u0438\u043c \u043e\u043f\u044b\u0442\u043e\u043c \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u0438 \u0442\u044f\u0436\u0435\u043b\u043e\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438. \u0426\u0435\u043d\u044b \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u043e\u0442 \u0437\u0430\u0432\u043e\u0434\u0430 \u0438\u0441\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u043d\u0430\u0446\u0435\u043d\u043a\u0438 \u0434\u0438\u0441\u0442\u0440\u0438\u0431\u044c\u044e\u0442\u043e\u0440\u043e\u0432, \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0435\u0442\u0441\u044f \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f IEC, \u0432\u044b\u0434\u0430\u043d\u043d\u0430\u044f \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u044f\u043c\u0438 CESI (\u0418\u0442\u0430\u043b\u0438\u044f) \u0438 KEMA.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>30\u201350% \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e \u0432 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0431\u0440\u0435\u043d\u0434\u0430\u043c\u0438 Tier-1 \u0441 \u044d\u043a\u0432\u0438\u0432\u0430\u043b\u0435\u043d\u0442\u043d\u043e\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c\u044e<\/li>\n\n\n\n<li>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d \u0434\u043b\u044f \u0432\u0437\u0440\u044b\u0432\u043e\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0441\u0440\u0435\u0434 (Ex d IIB, \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f MA \u0434\u043b\u044f \u0443\u0433\u043e\u043b\u044c\u043d\u044b\u0445 \u0448\u0430\u0445\u0442)<\/li>\n\n\n\n<li>\u0411\u044b\u0441\u0442\u0440\u0430\u044f \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 (7-\u0434\u043d\u0435\u0432\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043d\u0435\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0445 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439 \u043a\u0430\u0442\u0443\u0448\u043a\u0438)<\/li>\n\n\n\n<li>\u041f\u0440\u044f\u043c\u0430\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043e\u0442 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u043e\u0439 \u043a\u043e\u043c\u0430\u043d\u0434\u044b (\u0431\u0435\u0437 \u043f\u043e\u0441\u0440\u0435\u0434\u043d\u0438\u043a\u043e\u0432-\u0434\u0438\u0441\u0442\u0440\u0438\u0431\u044c\u044e\u0442\u043e\u0440\u043e\u0432)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u0435\u0442\u044c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0430 \u0410\u0437\u0438\u0430\u0442\u0441\u043a\u043e-\u0422\u0438\u0445\u043e\u043e\u043a\u0435\u0430\u043d\u0441\u043a\u0438\u043c \u0440\u0435\u0433\u0438\u043e\u043d\u043e\u043c + \u0438\u0437\u0431\u0440\u0430\u043d\u043d\u044b\u043c\u0438 \u0435\u0432\u0440\u043e\u043f\u0435\u0439\u0441\u043a\u0438\u043c\u0438 \u043f\u0430\u0440\u0442\u043d\u0435\u0440\u0430\u043c\u0438<\/li>\n\n\n\n<li>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u0430\u043d\u0433\u043b\u0438\u0439\u0441\u043a\u043e\u043c \u044f\u0437\u044b\u043a\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0432\u043e\u0434\u0430<\/li>\n\n\n\n<li>\u0423\u0437\u043d\u0430\u0432\u0430\u0435\u043c\u043e\u0441\u0442\u044c \u0431\u0440\u0435\u043d\u0434\u0430 \u043d\u0438\u0436\u0435, \u0447\u0435\u043c \u0443 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0445 \u0431\u0440\u0435\u043d\u0434\u043e\u0432 \u0443\u0440\u043e\u0432\u043d\u044f Tier-1 \u043d\u0430 \u0437\u0430\u043f\u0430\u0434\u043d\u044b\u0445 \u0440\u044b\u043d\u043a\u0430\u0445<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438, \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439, \u043b\u0438\u043d\u0438\u0438 \u043c\u0430\u0441\u0441\u043e\u0432\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430, \u043f\u0440\u043e\u0435\u043a\u0442\u044b \u043f\u043e \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0431\u044e\u0434\u0436\u0435\u0442\u043e\u043c<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-ls-electric-south-korea\">5. LS Electric (\u042e\u0436\u043d\u0430\u044f \u041a\u043e\u0440\u0435\u044f)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: VCF-12, VCC (\u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 7,2\u201324 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 500 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 6000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>LS Electric (\u0440\u0430\u043d\u0435\u0435 LG Industrial Systems) \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u043d\u0430 \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u043a\u0435 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439 \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0430. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 VCF-12 \u0438\u043c\u0435\u0435\u0442 \u0448\u0438\u0440\u0438\u043d\u0443 \u043d\u0430 30% \u043c\u0435\u043d\u044c\u0448\u0435, \u0447\u0435\u043c \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 ABB VM1, \u0447\u0442\u043e \u0438\u043c\u0435\u0435\u0442 \u0440\u0435\u0448\u0430\u044e\u0449\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0441\u0442\u0430\u0440\u0435\u0432\u0448\u0438\u0445 GIS-\u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043e\u0432.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041b\u0443\u0447\u0448\u0438\u0439 \u0432 \u043e\u0442\u0440\u0430\u0441\u043b\u0438 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0434\u0438\u0437\u0430\u0439\u043d (\u0448\u0438\u0440\u0438\u043d\u0430 165 \u043c\u043c \u0434\u043b\u044f 12 \u043a\u0412, 400 \u0410)<\/li>\n\n\n\n<li>\u0421\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0432 \u042e\u0436\u043d\u043e\u0439 \u041a\u043e\u0440\u0435\u0435, \u0441\u0443\u0434\u043e\u0441\u0442\u0440\u043e\u0435\u043d\u0438\u0435 \u0432 \u042e\u0433\u043e-\u0412\u043e\u0441\u0442\u043e\u0447\u043d\u043e\u0439 \u0410\u0437\u0438\u0438<\/li>\n\n\n\n<li>\u041a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u044b\u0435 \u0446\u0435\u043d\u044b (20% \u043d\u0438\u0436\u0435 ABB, 15% \u0432\u044b\u0448\u0435 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0430\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 Tier-1 (500 \u0442\u044b\u0441. \u043f\u0440\u043e\u0442\u0438\u0432 1 \u043c\u043b\u043d \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439)<\/li>\n\n\n\n<li>\u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0437\u0430 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u043c\u0438 \u0410\u0437\u0438\u0438<\/li>\n\n\n\n<li>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u0430\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043b\u0438\u0442\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u043d\u0430 \u0430\u043d\u0433\u043b\u0438\u0439\u0441\u043a\u043e\u043c \u044f\u0437\u044b\u043a\u0435<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041c\u043e\u0440\u0441\u043a\u0438\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f, \u043a\u043e\u0440\u0435\u0439\u0441\u043a\u0438\u0435 \u0432\u0435\u0440\u0444\u0438, \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0435 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438, \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f OEM<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6.-siemens-germany\">6. Siemens (\u0413\u0435\u0440\u043c\u0430\u043d\u0438\u044f)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: 3AH (\u0443\u0441\u0442\u0430\u0440\u0435\u0432\u0448\u0430\u044f \u0432\u0435\u0440\u0441\u0438\u044f), SIMOVAC (\u0433\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0439 VCB-\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 7,2\u201340,5 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 500 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 7000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>\u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Siemens \u043f\u0435\u0440\u0435\u043d\u0435\u0441\u043b\u0430 \u0430\u043a\u0446\u0435\u043d\u0442 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0433\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 SIMOVAC, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043e\u0447\u0435\u0442\u0430\u044e\u0442 \u0432 \u0441\u0435\u0431\u0435 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f (\u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439) \u0441 \u0447\u0430\u0441\u0442\u043e\u0439 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0435\u0439. \u0427\u0438\u0441\u0442\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b (\u0441\u0435\u0440\u0438\u044f 3AH) \u043f\u043e-\u043f\u0440\u0435\u0436\u043d\u0435\u043c\u0443 \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b, \u043d\u043e \u043f\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e \u0432\u044b\u0445\u043e\u0434\u044f\u0442 \u0438\u0437 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0432 \u043f\u043e\u043b\u044c\u0437\u0443 \u043c\u043e\u0434\u0443\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439 VCB.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0441 \u0440\u0435\u043b\u0435 Siemens SIPROTEC \u0438 \u043f\u043e\u0440\u0442\u0430\u043b\u043e\u043c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 TIA<\/li>\n\n\n\n<li>\u041c\u043e\u0449\u043d\u0430\u044f \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u0430\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0434\u043b\u044f \u043a\u0440\u0443\u043f\u043d\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a<\/li>\n\n\n\n<li>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u043d\u0435\u043c\u0435\u0446\u043a\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041b\u0438\u043d\u0435\u0439\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0443\u0442\u0440\u0430\u0442\u0438\u043b\u0430 \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442\u043d\u043e\u0441\u0442\u044c (Siemens \u043e\u0442\u0434\u0430\u0435\u0442 \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0435\u043d\u0438\u0435 VCB)<\/li>\n\n\n\n<li>\u0414\u043e\u0440\u043e\u0433\u043e \u0434\u043b\u044f \u0430\u0432\u0442\u043e\u043d\u043e\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439<\/li>\n\n\n\n<li>\u0414\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u0440\u043e\u043a\u0438 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0438 (16\u201320 \u043d\u0435\u0434\u0435\u043b\u044c)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041a\u0440\u0443\u043f\u043d\u044b\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u044b \u044d\u043a\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u044b Siemens, \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f \u0441 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0439 \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u043e\u0439 Siemens<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-3-volume-chinese-manufacturers\">\u0423\u0440\u043e\u0432\u0435\u043d\u044c 3: \u041a\u0440\u0443\u043f\u043d\u044b\u0435 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"7.-shandong-taikai-china\">7. Shandong Taikai (\u041a\u0438\u0442\u0430\u0439)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: CKG, CKGB (\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0442\u0438\u043f)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 6\u201312 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 300 000\u2013500 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 4000\u20136000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>Taikai \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u044e \u043d\u0430 \u043a\u0440\u0443\u043f\u043d\u044b\u0435 \u0440\u044b\u043d\u043a\u0438 OEM \u0432 \u041a\u0438\u0442\u0430\u0435 \u0438 \u044d\u043a\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u0443\u0435\u0442 \u0435\u0435 \u0446\u0435\u043d\u043e\u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u043c \u043f\u043e\u043a\u0443\u043f\u0430\u0442\u0435\u043b\u044f\u043c. \u0421 2015 \u0433\u043e\u0434\u0430 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0443\u043b\u0443\u0447\u0448\u0438\u043b\u0441\u044f \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u2014 \u0442\u0435\u043f\u0435\u0440\u044c \u0434\u043b\u044f \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0445 \u043b\u0438\u043d\u0435\u0435\u043a \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438 \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 IEC.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u0430\u043c\u0430\u044f \u043d\u0438\u0437\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0441\u0440\u0435\u0434\u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 (\u043d\u0430 40\u201360% \u043d\u0438\u0436\u0435 \u0443\u0440\u043e\u0432\u043d\u044f Tier-1)<\/li>\n\n\n\n<li>\u0411\u044b\u0441\u0442\u0440\u0430\u044f \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u0430 (4 \u043d\u0435\u0434\u0435\u043b\u0438 \u0441\u043e \u0441\u043a\u043b\u0430\u0434\u0430)<\/li>\n\n\n\n<li>\u0420\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u0438\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0435\u0439 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0438<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041d\u0435\u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u043f\u0430\u0440\u0442\u0438\u0438 (\u0438\u0437\u043c\u0435\u043d\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u044d\u0440\u043e\u0437\u0438\u0438 \u00b120%)<\/li>\n\n\n\n<li>\u041d\u0435\u043d\u0430\u0434\u0435\u0436\u043d\u0430\u044f \u0446\u0435\u043f\u043e\u0447\u043a\u0430 \u043f\u043e\u0441\u0442\u0430\u0432\u043e\u043a \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0434\u043b\u044f \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u0445 \u043a\u043b\u0438\u0435\u043d\u0442\u043e\u0432<\/li>\n\n\n\n<li>\u041a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u043d\u0435\u043e\u0434\u043d\u043e\u0440\u043e\u0434\u043d\u043e\u0435 (\u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u044b \u0445\u043e\u0440\u043e\u0448\u043e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u044b, \u0434\u0440\u0443\u0433\u0438\u0435 \u2014 \u0441\u043a\u0443\u0434\u043d\u043e)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041f\u0440\u043e\u0435\u043a\u0442\u044b \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0431\u044e\u0434\u0436\u0435\u0442\u043e\u043c, \u043e\u0442\u0435\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 OEM-\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438, \u043d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"8.-nanjing-electric-china\">8. Nanjing Electric (\u041a\u0438\u0442\u0430\u0439)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: JN15, JN27 (\u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u0439 \u043f\u043e\u043b\u044e\u0441\u043d\u044b\u0439 \u0442\u0438\u043f)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 12\u201327,5 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 500 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 5000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>\u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Nanjing Electric (\u0440\u0430\u043d\u0435\u0435 Nanjing Automation Works) \u0437\u0430\u043d\u0438\u043c\u0430\u0435\u0442 \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u0443\u044e \u043f\u043e\u0437\u0438\u0446\u0438\u044e \u0432 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u043e\u043c \u0441\u0435\u043a\u0442\u043e\u0440\u0435 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u0443\u0433. \u041f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u044f \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0430 \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0436\u0435\u043b\u0435\u0437\u043d\u044b\u0445 \u0434\u043e\u0440\u043e\u0433 \u0438 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0439.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0436\u0435\u043b\u0435\u0437\u043d\u043e\u0434\u043e\u0440\u043e\u0436\u043d\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0430 (\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b TB\/T) \u0434\u043b\u044f \u0442\u044f\u0433\u043e\u0432\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439<\/li>\n\n\n\n<li>\u0421\u043e\u0437\u0434\u0430\u043d\u0430 \u0446\u0435\u043f\u043e\u0447\u043a\u0430 \u043f\u043e\u0441\u0442\u0430\u0432\u043e\u043a \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u043e\u0439 \u0433\u043e\u0441\u0443\u0434\u0430\u0440\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0435\u0432\u043e\u0439 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438<\/li>\n\n\n\n<li>\u0423\u043c\u0435\u0440\u0435\u043d\u043d\u044b\u0435 \u0446\u0435\u043d\u044b (30% \u043d\u0438\u0436\u0435 Tier-1, 20% \u0432\u044b\u0448\u0435 \u043e\u0431\u044b\u0447\u043d\u044b\u0445 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0445)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u0430\u044f \u043e\u0440\u0438\u0435\u043d\u0442\u0430\u0446\u0438\u044f \u043d\u0430 \u044d\u043a\u0441\u043f\u043e\u0440\u0442\u043d\u044b\u0435 \u0440\u044b\u043d\u043a\u0438 (\u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u043c\u0443 \u0440\u044b\u043d\u043a\u0443 \u041a\u0438\u0442\u0430\u044f)<\/li>\n\n\n\n<li>\u0421\u043b\u0430\u0431\u0430\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u0430 \u0430\u043d\u0433\u043b\u0438\u0439\u0441\u043a\u043e\u043c \u044f\u0437\u044b\u043a\u0435<\/li>\n\n\n\n<li>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043d\u0430 \u043d\u0438\u0436\u043d\u0435\u0439 \u0433\u0440\u0430\u043d\u0438\u0446\u0435 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u041a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u0436\u0435\u043b\u0435\u0437\u043d\u043e\u0434\u043e\u0440\u043e\u0436\u043d\u044b\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u044b, \u043f\u043e\u0434\u0440\u044f\u0434\u0447\u0438\u043a\u0438 State Grid, \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438 \u0442\u044f\u0433\u043e\u0432\u043e\u0433\u043e \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u044f<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"9.-hubbell-usa\">9. \u0425\u0430\u0431\u0431\u0435\u043b\u043b (\u0421\u0428\u0410)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: SCC (\u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 2,4\u201315 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 250 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 5000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>Hubbell \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u0435\u0442 \u043d\u0438\u0448\u0435\u0432\u044b\u0435 \u0440\u044b\u043d\u043a\u0438 \u0421\u0435\u0432\u0435\u0440\u043d\u043e\u0439 \u0410\u043c\u0435\u0440\u0438\u043a\u0438, \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u0432\u0437\u0440\u044b\u0432\u043e\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0437\u043e\u043d (\u043a\u043b\u0430\u0441\u0441 I, \u0440\u0430\u0437\u0434\u0435\u043b 2) \u0438 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 UL \u0434\u043b\u044f \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0437\u043e\u043d (\u043d\u0435\u0444\u0442\u0435\u0433\u0430\u0437\u043e\u0432\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c, \u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0437\u0430\u0432\u043e\u0434\u044b)<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u0432 \u0421\u0428\u0410 (\u0431\u043e\u043b\u0435\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0435 \u0441\u0440\u043e\u043a\u0438 \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432)<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0447\u043d\u044b\u0435 \u0441\u0432\u044f\u0437\u0438 \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u043c \u0441\u0435\u043a\u0442\u043e\u0440\u0435<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0430\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043c\u0438\u0440\u043e\u0432\u044b\u043c\u0438 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u0430\u043c\u0438<\/li>\n\n\n\n<li>\u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0430\u0437\u0438\u0430\u0442\u0441\u043a\u0438\u043c\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f\u043c\u0438 \u0431\u0435\u0437 \u0441\u043e\u0440\u0430\u0437\u043c\u0435\u0440\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438<\/li>\n\n\n\n<li>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u0430\u044f \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u0430\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432 \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0437\u043e\u043d\u0430\u0445 \u0421\u0428\u0410, \u0448\u0430\u0445\u0442\u044b, \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0435 MSHA, \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u044b Buy America<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"10.-toshiba-japan\">10. Toshiba (\u042f\u043f\u043e\u043d\u0438\u044f)<\/h3>\n\n\n\n<p><strong>\u041b\u0438\u043d\u0435\u0439\u043a\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/strong>: VK (\u0443\u0441\u0442\u0430\u0440\u0435\u0432\u0448\u0430\u044f \u0441\u0435\u0440\u0438\u044f, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e)<br><strong>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: 7,2\u201324 \u043a\u0412<br><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b<\/strong>: 300 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<br><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 (AC-4)<\/strong>: 6000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n\n\n\n<p>\u0412 2018 \u0433\u043e\u0434\u0443 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Toshiba \u043f\u0440\u0435\u043a\u0440\u0430\u0442\u0438\u043b\u0430 \u0430\u043a\u0442\u0438\u0432\u043d\u0443\u044e \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u043a\u0443 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u0441\u043e\u0441\u0440\u0435\u0434\u043e\u0442\u043e\u0447\u0438\u0432\u0448\u0438\u0441\u044c \u043d\u0430 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430\u0445 VCB \u0438 GIS. \u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b VK \u043f\u043e-\u043f\u0440\u0435\u0436\u043d\u0435\u043c\u0443 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u043e\u0439 \u0431\u0430\u0437\u044b, \u043d\u043e \u0432 \u043d\u043e\u0432\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441\u0442\u043e\u0440\u043e\u043d\u043d\u0438\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 (\u0447\u0430\u0441\u0442\u043e LS Electric OEM).<\/p>\n\n\n\n<p><strong>\u0421\u0438\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0420\u0435\u043f\u0443\u0442\u0430\u0446\u0438\u044f \u044f\u043f\u043e\u043d\u0441\u043a\u043e\u0433\u043e \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 (\u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0442\u0440\u0430\u0434\u0438\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432)<\/li>\n\n\n\n<li>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0441 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u043c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435\u043c Toshiba GIS\/VCB<\/li>\n\n\n\n<li>\u0421\u0438\u043b\u044c\u043d\u0430\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u0430\u044f \u0431\u0430\u0437\u0430 \u0432 \u044f\u043f\u043e\u043d\u0441\u043a\u0438\u0445 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f\u0445<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041b\u0438\u043d\u0435\u0439\u043a\u0430 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432 \u0441\u043d\u044f\u0442\u0430 \u0441 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 (\u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u043f\u0447\u0430\u0441\u0442\u0435\u0439 \u0441\u043d\u0438\u0436\u0430\u0435\u0442\u0441\u044f)<\/li>\n\n\n\n<li>\u041d\u0435\u0442 \u043d\u043e\u0432\u044b\u0445 \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u043e\u043a \u0438\u043b\u0438 \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0439 \u0434\u0438\u0437\u0430\u0439\u043d\u0430<\/li>\n\n\n\n<li>\u041f\u0440\u0435\u043c\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0446\u0435\u043d\u044b \u0431\u0435\u0437 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u043d\u044b\u0445 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u0417\u0430\u043c\u0435\u043d\u0430 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f Toshiba, \u0442\u043e\u043b\u044c\u043a\u043e \u0434\u043b\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0433\u043e \u0440\u044b\u043d\u043a\u0430 \u042f\u043f\u043e\u043d\u0438\u0438<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02.webp\" alt=\"\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0446\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b, \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438, \u0446\u0435\u043d\u044b \u0438 \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u043e\u0432 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u043e\u0439 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0438\" class=\"wp-image-2389\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0418\u0421. 02: \u041c\u0430\u0442\u0440\u0438\u0446\u0430 \u0432\u044b\u0431\u043e\u0440\u0430, \u0441\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u044e\u0449\u0430\u044f 10 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043f\u043e \u043a\u043b\u044e\u0447\u0435\u0432\u044b\u043c \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0430\u043c: \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c, \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 AC-4, \u0446\u0435\u043d\u043e\u0432\u043e\u0435 \u043f\u043e\u0437\u0438\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u043e\u0439 \u0441\u0435\u0442\u0438.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-decision-matrix\">\u041c\u0430\u0442\u0440\u0438\u0446\u0430 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u044f \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u043e \u0432\u044b\u0431\u043e\u0440\u0435<\/h2>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0435 \u0437\u0430\u0434\u0430\u0447\u0438 (\u0430\u0442\u043e\u043c\u043d\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u043a\u0430, \u0441\u0443\u0434\u043e\u0441\u0442\u0440\u043e\u0435\u043d\u0438\u0435, \u043d\u0435\u0444\u0442\u0435\u0433\u0430\u0437\u043e\u0432\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c)<\/strong><br>\u2192 ABB, Schneider, Eaton<br>\u041f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442: \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c, \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435, \u043f\u043e\u043b\u043d\u0430\u044f \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<br>\u041f\u0440\u0438\u043d\u044f\u0442\u044c: 30\u201340% \u043d\u0430\u0434\u0431\u0430\u0432\u043a\u0430 \u043a \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438<\/p>\n\n\n\n<p><strong>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e (\u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c, \u0432\u043e\u0434\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435, HVAC)<\/strong><br>\u2192 XBRELE, LS Electric, Siemens<br>\u041f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442: \u0441\u043e\u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c IEC, \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438<br>\u041f\u0440\u0438\u043d\u044f\u0442\u044c: \u0443\u043c\u0435\u0440\u0435\u043d\u043d\u044b\u0435 \u0441\u0440\u043e\u043a\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f<\/p>\n\n\n\n<p><strong>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u043f\u0430\u043d\u0435\u043b\u0435\u0439 OEM (\u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u043e\u0431\u044a\u0435\u043c)<\/strong><br>\u2192 XBRELE, Taikai, Nanjing Electric<br>\u041f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442: \u0446\u0435\u043d\u044b \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u043e\u0442 \u0437\u0430\u0432\u043e\u0434\u0430, \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u0435 \u0437\u0430\u043a\u0430\u0437\u043e\u0432, \u0433\u0438\u0431\u043a\u043e\u0441\u0442\u044c \u0434\u0438\u0437\u0430\u0439\u043d\u0430<br>\u041f\u0440\u0438\u043d\u044f\u0442\u044c: \u0421\u0430\u043c\u043e\u0441\u0442\u043e\u044f\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0437\u0430\u043f\u0430\u0441\u0430\u043c\u0438 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439<\/p>\n\n\n\n<p><strong>\u0421 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0431\u044e\u0434\u0436\u0435\u0442\u043e\u043c \/ \u041d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u043d\u044b\u0439<\/strong><br>\u2192 \u0422\u0430\u0439\u043a\u0430\u0439, \u0425\u0430\u0431\u0431\u0435\u043b\u043b (\u0442\u043e\u043b\u044c\u043a\u043e \u0434\u043b\u044f \u0421\u0428\u0410)<br>\u041f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442: \u041d\u0430\u0438\u043c\u0435\u043d\u044c\u0448\u0430\u044f \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c<br>\u041f\u0440\u0438\u043d\u044f\u0442\u044c: \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u0430\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430<\/p>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 \u0431\u043e\u043b\u0435\u0435 \u0447\u0435\u043c 200 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0443\u0440\u043e\u0432\u043d\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442 \u043d\u0435\u0437\u0430\u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043f\u0440\u043e\u0441\u0442\u043e\u0438 \u043d\u0430 40% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c\u0438 \u0432\u044b\u0431\u043e\u0440\u0430\u043c\u0438 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0443\u0440\u043e\u0432\u043d\u044f 3 \u0432 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u043e\u043c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0438 \u0434\u043b\u044f \u043f\u043e\u0434\u044a\u0435\u043c\u043d\u044b\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u0432 \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438).<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u043e\u0433\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044f&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vacuum-vs-air-contactor-mining-safety-jcz-upgrade-benefits\/\">\u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0438 \u043f\u043d\u0435\u0432\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438<\/a>, \u043f\u043e\u043b\u0435\u0432\u044b\u0435 \u0434\u0430\u043d\u043d\u044b\u0435 \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0442 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438 \u0432 \u043f\u043b\u0430\u043d\u0435 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0438 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-procurement-mistakes\">\u0420\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 \u043f\u0440\u0438 \u0437\u0430\u043a\u0443\u043f\u043a\u0430\u0445<\/h2>\n\n\n\n<p><strong>\u041e\u0448\u0438\u0431\u043a\u0430 #1: \u043f\u043e\u0431\u0435\u0436\u0434\u0430\u0435\u0442 \u0441\u0430\u043c\u0430\u044f \u043d\u0438\u0437\u043a\u0430\u044f \u0446\u0435\u043d\u0430<\/strong><\/p>\n\n\n\n<p>\u0417\u0430\u043f\u0440\u043e\u0441 \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u201c12 \u043a\u0412, 400 \u0410, \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 AC-4\u201d \u0431\u0435\u0437 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443\/\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u0441\u0440\u043e\u043a\u0443 \u0441\u043b\u0443\u0436\u0431\u044b \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f\u043c \u0434\u043b\u044f \u0443\u0447\u0430\u0441\u0442\u043d\u0438\u043a\u043e\u0432 \u0441 \u0441\u0430\u043c\u044b\u043c\u0438 \u043d\u0438\u0437\u043a\u0438\u043c\u0438 \u0446\u0435\u043d\u0430\u043c\u0438. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0441 300 000 \u0446\u0438\u043a\u043b\u0430\u043c\u0438 \u0440\u0430\u0431\u043e\u0442\u044b \u0441\u0442\u043e\u0438\u0442 \u043d\u0430 40% \u043c\u0435\u043d\u044c\u0448\u0435, \u0447\u0435\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0441 1 000 000 \u0446\u0438\u043a\u043b\u0430\u043c\u0438, \u043d\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0432 3,3 \u0440\u0430\u0437\u0430 \u0447\u0430\u0449\u0435.<\/p>\n\n\n\n<p><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0423\u043a\u0430\u0436\u0438\u0442\u0435 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435: \u2265500 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 IEC 62271-106 \u043a\u043b\u0430\u0441\u0441 M1\u201d<\/li>\n\n\n\n<li>\u201c\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 AC-4: \u22656000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u0440\u0438 400 \u0410\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0448\u0438\u0431\u043a\u0430 #2: \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u0438 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439<\/strong><\/p>\n\n\n\n<p>40-\u043d\u0435\u0434\u0435\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0438 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0435\u0439 \u043e\u0442 \u0435\u0432\u0440\u043e\u043f\u0435\u0439\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043d\u0435\u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u044b\u0439 \u0440\u0438\u0441\u043a \u043f\u0440\u043e\u0441\u0442\u043e\u044f \u0434\u043b\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u044b\u0445 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u0439. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 \u0434\u043e\u043b\u0436\u043d\u044b \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u0437\u0430\u043f\u0430\u0441\u0442\u0438\u0441\u044c \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u043c\u0438 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u043c\u0438 \u0447\u0430\u0441\u0442\u044f\u043c\u0438 \u0438\u043b\u0438 \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0443 \u0434\u0435\u0442\u0430\u043b\u0435\u0439 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043c\u0435\u043d\u0435\u0435 4 \u043d\u0435\u0434\u0435\u043b\u044c.<\/p>\n\n\n\n<p><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0412\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u043e\u0446\u0435\u043d\u043a\u0443 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u041f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0437\u0430\u043f\u0430\u0441\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043d\u0430 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0443 VI \u0438 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0431\u044a\u0435\u043c \u0437\u0430\u043a\u0430\u0437\u0430\u201d<\/li>\n\n\n\n<li>\u201c\u0421\u043f\u0438\u0441\u043e\u043a \u0440\u0435\u0433\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u044b\u0445 \u0446\u0435\u043d\u0442\u0440\u043e\u0432 \u0432 \u0440\u0430\u0434\u0438\u0443\u0441\u0435 500 \u043a\u043c \u043e\u0442 \u043e\u0431\u044a\u0435\u043a\u0442\u0430\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0448\u0438\u0431\u043a\u0430 #3: \u043a\u043e\u043f\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0431\u0440\u0435\u043d\u0434\u0430 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u0430 \u0431\u0435\u0437 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438<\/strong><\/p>\n\n\n\n<p>\u201c\u041a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442 X \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 ABB, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043c\u044b \u0442\u043e\u0436\u0435 \u0431\u0443\u0434\u0435\u043c\u201d \u2014 \u044d\u0442\u043e \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u0443\u0435\u0442 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f \u0432 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0438. \u0415\u0441\u043b\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442\u0430 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 50 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0434\u0435\u043d\u044c, \u0430 \u0432\u0430\u0448\u0435 \u2014 300 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0434\u0435\u043d\u044c, \u0432\u0430\u043c \u043d\u0443\u0436\u043d\u044b \u0440\u0430\u0437\u043d\u044b\u0435 \u043a\u043b\u0430\u0441\u0441\u044b \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u0438, \u0447\u0442\u043e \u043f\u043e\u0442\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u043e\u043f\u0440\u0430\u0432\u0434\u044b\u0432\u0430\u0435\u0442 \u043f\u0440\u0435\u043c\u0438\u0443\u043c-\u0443\u0440\u043e\u0432\u0435\u043d\u044c Tier-1, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u043a\u043e\u043d\u043a\u0443\u0440\u0435\u043d\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 Tier-2.<\/p>\n\n\n\n<p><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0412\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0430\u043d\u0430\u043b\u0438\u0437 \u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u0446\u0438\u043a\u043b\u0430:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0420\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u0439\u0442\u0435 \u0433\u043e\u0434\u043e\u0432\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438: \u0446\u0438\u043a\u043b\u044b\/\u0434\u0435\u043d\u044c \u00d7 365<\/li>\n\n\n\n<li>\u041e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u043c\u044b\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441: (\u0433\u043e\u0434\u043e\u0432\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u00d7 \u0446\u0435\u043b\u0435\u0432\u043e\u0439 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b \u0432 \u0433\u043e\u0434\u0430\u0445)<\/li>\n\n\n\n<li>\u0421\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u044c\u0442\u0435 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0441 \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u043c\u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\n\n\n\n<p>\u0412\u044b\u0431\u043e\u0440 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430, \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043d\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0438 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u0443\u044e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 15\u201325 \u043b\u0435\u0442 \u0441\u043b\u0443\u0436\u0431\u044b. \u041c\u0438\u0440\u043e\u0432\u044b\u0435 \u0431\u0440\u0435\u043d\u0434\u044b \u0443\u0440\u043e\u0432\u043d\u044f 1 (ABB, Schneider, Eaton) \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u0434\u043e\u043b\u0433\u043e\u0432\u0435\u0447\u043d\u043e\u0441\u0442\u044c \u0438 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u0443\u044e \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0443 \u043f\u043e \u0446\u0435\u043d\u0435 30\u201340%. \u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u044b OEM (XBRELE, LS Electric) \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0431\u0430\u043b\u0430\u043d\u0441 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c\u044e \u0438 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c\u044e \u0434\u043b\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0445 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439. \u041a\u0440\u0443\u043f\u043d\u044b\u0435 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 (Taikai, Nanjing) \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u043a\u0443\u043f\u0430\u0442\u0435\u043b\u0435\u0439 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0431\u044e\u0434\u0436\u0435\u0442\u043e\u043c, \u0433\u043e\u0442\u043e\u0432\u044b\u0445 \u0441\u043e\u0433\u043b\u0430\u0441\u0438\u0442\u044c\u0441\u044f \u043d\u0430 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f\u043c\u0438.<\/p>\n\n\n\n<p>\u0412\u044b\u0431\u043e\u0440 \u201c\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e\u201d \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f, \u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u0446\u0438\u043a\u043b\u0430 \u0438 \u0430\u043d\u0430\u043b\u0438\u0437\u0430 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0439 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u0432\u043b\u0430\u0434\u0435\u043d\u0438\u044f, \u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0442 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0439 \u043f\u043e\u043a\u0443\u043f\u043d\u043e\u0439 \u0446\u0435\u043d\u044b. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 $2000, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0437\u0430\u043c\u0435\u043d\u044b \u043a\u0430\u0436\u0434\u044b\u0435 7 \u043b\u0435\u0442, \u0437\u0430 25 \u043b\u0435\u0442 \u043e\u0431\u043e\u0439\u0434\u0435\u0442\u0441\u044f \u0434\u043e\u0440\u043e\u0436\u0435, \u0447\u0435\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 $3500, \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043a\u043e\u0442\u043e\u0440\u043e\u0433\u043e \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 15 \u043b\u0435\u0442, \u0434\u0430\u0436\u0435 \u0431\u0435\u0437 \u0443\u0447\u0435\u0442\u0430 \u043f\u0440\u043e\u0441\u0442\u043e\u0435\u0432 \u0438 \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u0440\u0430\u0431\u043e\u0447\u0443\u044e \u0441\u0438\u043b\u0443.<\/p>\n\n\n\n<p>\u0421\u043e\u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0441 \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f\u043c\u0438 \u0441\u0431\u043e\u0435\u0432: \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u043e\u043f\u0440\u0430\u0432\u0434\u0430\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u0435\u043c\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0431\u0440\u0435\u043d\u0434\u043e\u0432, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u0434\u043b\u044f \u043d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a \u0441 \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u0430\u043c\u0438 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435 \u043c\u043e\u0436\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u044b\u0435 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u044b. \u0425\u0443\u0434\u0448\u0435\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u2014 \u0432\u044b\u0431\u0440\u0430\u0442\u044c Tier-3 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u043f\u043b\u0430\u0447\u0438\u0432\u0430\u0442\u044c \u0437\u0430 Tier-1 \u0434\u043b\u044f \u043d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u2014 \u0432 \u043e\u0431\u043e\u0438\u0445 \u0441\u043b\u0443\u0447\u0430\u044f\u0445 \u0432\u044b \u0442\u0440\u0430\u0442\u0438\u0442\u0435 \u0434\u0435\u043d\u044c\u0433\u0438, \u043f\u0440\u043e\u0441\u0442\u043e \u0432 \u0440\u0430\u0437\u043d\u044b\u0445 \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f\u0445.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vacuum-contactor-manufacturers\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b: \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/h2>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 1: \u0412 \u0447\u0435\u043c \u0440\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f\u043c\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0443\u0440\u043e\u0432\u043d\u044f 1 \u0438 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u043c\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f\u043c\u0438?<\/strong><\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0443\u0440\u043e\u0432\u043d\u044f 1 (ABB, Schneider, Eaton) \u043e\u0431\u044b\u0447\u043d\u043e \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u044e\u0442 1 000 000 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439, 8 000\u201312 000 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0446\u0438\u043a\u043b\u043e\u0432 AC-4, \u043f\u043e\u043b\u043d\u0443\u044e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044e \u043f\u043e \u0442\u0438\u043f\u043e\u0432\u044b\u043c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c \u043e\u0442 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0439 (KEMA, CPRI) \u0438 \u0433\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0435 \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u044b\u0435 \u0441\u0435\u0442\u0438 \u0441 \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u043e\u0439 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043c\u0435\u043d\u0435\u0435 48 \u0447\u0430\u0441\u043e\u0432. \u041a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u044e\u0442\u0441\u044f \u043e\u0442 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u043e\u0432 \u043f\u043e \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 OEM, \u0442\u0430\u043a\u0438\u0445 \u043a\u0430\u043a XBRELE (1 \u043c\u043b\u043d \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445, 8000 AC-4, \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 IEC) \u0441 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0435\u0439 \u0437\u0430\u0442\u0440\u0430\u0442 30\u201350%, \u0434\u043e \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u043e\u0432 \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u043e\u0431\u044a\u0435\u043c\u043e\u0432 (300 000 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445, 4000 AC-4) \u0441 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0435\u0439 50\u201360%, \u043d\u043e \u0441 \u043d\u0435\u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430. \u0420\u0430\u0437\u0440\u044b\u0432 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u043b\u0441\u044f \u2014 \u0432\u0435\u0434\u0443\u0449\u0438\u0435 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 OEM-\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0442\u0435\u043f\u0435\u0440\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c Tier-1, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044f \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430 \u043f\u043e \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u0437\u0430 \u0441\u0447\u0435\u0442 \u043f\u0440\u044f\u043c\u044b\u0445 \u043f\u0440\u043e\u0434\u0430\u0436 \u0441 \u0437\u0430\u0432\u043e\u0434\u0430 \u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0432 \u0410\u0437\u0438\u0438.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441?<\/strong><\/p>\n\n\n\n<p>\u0417\u0430\u043f\u0440\u0430\u0448\u0438\u0432\u0430\u0439\u0442\u0435 \u043f\u043e\u043b\u043d\u044b\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 IEC 62271-106, \u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0434\u0435\u043a\u043b\u0430\u0440\u0430\u0446\u0438\u0438 \u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438. \u0412 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u0430\u0445 \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0443\u043a\u0430\u0437\u0430\u043d\u044b: (1) \u043d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u0438 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u0430\u0446\u0438\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 (KEMA, CESI, CPRI, \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u0430\u044f NEMA), (2) \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439, \u0434\u043e\u0441\u0442\u0438\u0433\u043d\u0443\u0442\u043e\u0435 \u0432 \u0445\u043e\u0434\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u0432\u044b\u043d\u043e\u0441\u043b\u0438\u0432\u043e\u0441\u0442\u044c, (3) \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 (\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435, \u0442\u043e\u043a, \u0440\u0430\u0431\u043e\u0447\u0438\u0439 \u0446\u0438\u043a\u043b), (4) \u0434\u0430\u0442\u0430 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 (\u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0432\u043e\u0437\u0440\u0430\u0441\u0442\u043e\u043c &gt; 10 \u043b\u0435\u0442 \u043c\u043e\u0433\u0443\u0442 \u043d\u0435 \u043e\u0442\u0440\u0430\u0436\u0430\u0442\u044c \u0442\u0435\u043a\u0443\u0449\u0435\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u043e). \u041f\u0440\u043e\u0432\u0435\u0440\u044f\u0439\u0442\u0435 \u043e\u0431\u043b\u0430\u0441\u0442\u044c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 \u043d\u0435\u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u0432 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f\u0445 \u043a \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u0443 \u0438 \u0432 \u0441\u043f\u0440\u0430\u0432\u043a\u0430\u0445 \u043e\u0440\u0433\u0430\u043d\u0430, \u0432\u044b\u0434\u0430\u0432\u0448\u0435\u0433\u043e \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442. \u0414\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0437\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u0435 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u043f\u0440\u0438\u0435\u043c\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 (FAT), \u0432 \u0445\u043e\u0434\u0435 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0432\u0430\u0448 \u0438\u043d\u0441\u043f\u0435\u043a\u0442\u043e\u0440 \u0431\u0443\u0434\u0435\u0442 \u043d\u0430\u0431\u043b\u044e\u0434\u0430\u0442\u044c \u0437\u0430 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u043d\u044b\u043c\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438 \u043d\u0430 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432. \u0412 \u0445\u043e\u0434\u0435 \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0435\u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043c\u044b \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043b\u0438 \u0440\u0430\u0441\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u043c \u0438 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0441\u0440\u043e\u043a\u043e\u043c \u0441\u043b\u0443\u0436\u0431\u044b \u0432 40%.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0441\u043c\u0435\u0448\u0438\u0432\u0430\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0437\u043d\u044b\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0432 \u043e\u0434\u043d\u043e\u0439 \u043f\u0430\u043d\u0435\u043b\u0438?<\/strong><\/p>\n\n\n\n<p>\u0414\u0430, \u043d\u043e \u0441 \u043e\u0441\u0442\u043e\u0440\u043e\u0436\u043d\u043e\u0441\u0442\u044c\u044e \u0432 \u0442\u0440\u0435\u0445 \u043c\u043e\u043c\u0435\u043d\u0442\u0430\u0445: (1)&nbsp;<strong>\u0421\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>\u2014\u0443\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 (110 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, 220 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438 \u0442. \u0434.), \u0430 \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u044f\u0435\u043c\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u043d\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0446\u0435\u043f\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f; (2)&nbsp;<strong>\u0424\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u044b<\/strong>\u2014\u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u044b\u0445 \u043e\u0442\u0432\u0435\u0440\u0441\u0442\u0438\u0439 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0437\u0430\u0437\u043e\u0440\u0430\u043c \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u044e\u0442\u0441\u044f \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f, \u0447\u0442\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043a\u043e\u043c\u043f\u043e\u043d\u043e\u0432\u043a\u0438 \u043f\u0430\u043d\u0435\u043b\u0438; (3)&nbsp;<strong>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432<\/strong>\u2014\u0440\u0430\u0437\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (NO\/NC) \u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0442\u043e\u043a\u0438; \u0437\u0430\u043c\u0435\u043d\u0430 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 10 \u0410 \u0432 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0438, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0435\u043c 15 \u0410, \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u0431\u043e\u044f\u043c. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u043d\u0430 \u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0443\u043f\u0440\u043e\u0449\u0430\u0435\u0442 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0437\u0430\u043f\u0430\u0441\u0430\u043c\u0438 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0438 \u043e\u0431\u0443\u0447\u0435\u043d\u0438\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b\u0430, \u0441\u043d\u0438\u0436\u0430\u044f \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u044b\u0439 \u0446\u0438\u043a\u043b \u043d\u0430 15\u201320% \u0432 \u043d\u0430\u0448\u0435\u043c \u0430\u043d\u0430\u043b\u0438\u0437\u0435 \u043f\u0430\u0440\u043a\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0435\u043c \u0431\u043e\u043b\u0435\u0435 500 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 4: \u041a\u0430\u043a\u0443\u044e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044e \u044f \u0434\u043e\u043b\u0436\u0435\u043d \u0437\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u044c \u0443 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432?<\/strong><\/p>\n\n\n\n<p>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e\u0435: (1)&nbsp;<strong>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/strong>&nbsp;(IEC 62271-106 \u0438\u043b\u0438 \u044d\u043a\u0432\u0438\u0432\u0430\u043b\u0435\u043d\u0442\u043d\u044b\u0439) \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439\/\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438, \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b, \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438; (2)&nbsp;<strong>\u0418\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438<\/strong>&nbsp;\u0441 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u0430\u043c\u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u043c\u0438 \u0438\u0437\u043d\u043e\u0441\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438 \u043a\u0440\u0443\u0442\u044f\u0449\u0435\u0433\u043e \u043c\u043e\u043c\u0435\u043d\u0442\u0430; (3)&nbsp;<strong>\u0420\u0430\u0437\u043c\u0435\u0440\u043d\u044b\u0435 \u0447\u0435\u0440\u0442\u0435\u0436\u0438<\/strong>&nbsp;(\u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0432 \u0444\u043e\u0440\u043c\u0430\u0442\u0435 CAD) \u0441 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u044b\u043c\u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u0430\u043c\u0438, \u0437\u043e\u043d\u0430\u043c\u0438 \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0441\u0442\u0432\u0430, \u0434\u0435\u0442\u0430\u043b\u044f\u043c\u0438 \u043e\u043a\u043e\u043d\u0435\u0447\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439; (4)&nbsp;<strong>\u0421\u043f\u0438\u0441\u043e\u043a \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439<\/strong>&nbsp;\u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u043d\u043e\u043c\u0435\u0440\u043e\u0432 \u0434\u0435\u0442\u0430\u043b\u0435\u0439, \u0441\u0440\u043e\u043a\u043e\u0432 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0438, \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u043e\u0431\u044a\u0435\u043c\u043e\u0432 \u0437\u0430\u043a\u0430\u0437\u0430. \u0414\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0434\u043e\u0431\u0430\u0432\u044c\u0442\u0435: (5)&nbsp;<strong>\u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f FAT\/SAT<\/strong>, (6)&nbsp;<strong>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f \u043f\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044e \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430<\/strong>&nbsp;(\u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 ISO 9001, \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u044b \u043f\u0440\u043e\u0432\u0435\u0440\u043e\u043a), (7)&nbsp;<strong>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432<\/strong>&nbsp;\u0434\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f (\u0441\u043e\u0441\u0442\u0430\u0432 \u0441\u043f\u043b\u0430\u0432\u0430 CuCr). \u041e\u0442\u043a\u043b\u043e\u043d\u044f\u0442\u044c \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u044f, \u043d\u0435 \u0438\u043c\u0435\u044e\u0449\u0438\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0432 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u2014 \u201c\u0437\u0430\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438\u201d \u0431\u0435\u0437 \u0434\u0430\u043d\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0435 \u043f\u043e\u0434\u0434\u0430\u044e\u0442\u0441\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 5: \u0421\u043a\u043e\u043b\u044c\u043a\u043e \u0434\u043e\u043b\u0436\u043d\u044b \u0441\u0442\u043e\u0438\u0442\u044c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438?<\/strong><\/p>\n\n\n\n<p>\u0411\u0430\u0437\u043e\u0432\u0430\u044f \u0446\u0435\u043d\u0430 12 \u043a\u0412, 400 \u0410, AC-4 (2025 \u0433.): \u0411\u0440\u0435\u043d\u0434\u044b \u0443\u0440\u043e\u0432\u043d\u044f 1 (ABB, Schneider) $3,500\u2013$5,000 \u0437\u0430 \u0435\u0434\u0438\u043d\u0438\u0446\u0443; \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 OEM-\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 (XBRELE, LS Electric) $2,000\u2013$3,000; \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u0438 \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u043e\u0431\u044a\u0435\u043c\u043e\u0432 $1,200\u2013$2,000. \u0426\u0435\u043d\u0430 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (24 \u043a\u0412 \u0441\u0442\u043e\u0438\u0442 \u0432 1,5\u20131,8 \u0440\u0430\u0437\u0430 \u0434\u043e\u0440\u043e\u0436\u0435, \u0447\u0435\u043c 12 \u043a\u0412), \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (630 \u0410 \u0441\u0442\u043e\u0438\u0442 \u0432 1,3\u20131,5 \u0440\u0430\u0437\u0430 \u0434\u043e\u0440\u043e\u0436\u0435, \u0447\u0435\u043c 400 \u0410) \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a (\u0432\u044b\u0434\u0432\u0438\u0436\u043d\u043e\u0439 \u0438\u043b\u0438 \u0441\u0442\u0430\u0446\u0438\u043e\u043d\u0430\u0440\u043d\u044b\u0439: +20\u201330%, \u0432\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u044b\u0439 \u043a\u043e\u0440\u043f\u0443\u0441: +50\u201380%). \u0421\u043a\u0438\u0434\u043a\u0438 \u0437\u0430 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e: 10\u201315% \u043f\u0440\u0438 \u043f\u043e\u043a\u0443\u043f\u043a\u0435 5 \u0438 \u0431\u043e\u043b\u0435\u0435 \u0435\u0434\u0438\u043d\u0438\u0446, 20\u201325% \u043f\u0440\u0438 \u043f\u043e\u043a\u0443\u043f\u043a\u0435 20 \u0438 \u0431\u043e\u043b\u0435\u0435 \u0435\u0434\u0438\u043d\u0438\u0446. \u041e\u0431\u0449\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u043b\u0430\u0434\u0435\u043d\u0438\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 20 \u043b\u0435\u0442 \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 (\u0437\u0430\u043c\u0435\u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043a\u0430\u0436\u0434\u044b\u0435 6000\u201310 000 \u0446\u0438\u043a\u043b\u043e\u0432 AC-4 \u043f\u043e \u0446\u0435\u043d\u0435 $800\u2013$1500 \u0437\u0430 VI), \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043f\u0440\u043e\u0441\u0442\u043e\u0438 \u0438 \u0437\u0430\u043f\u0430\u0441 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u2014 \u0447\u0430\u0441\u0442\u043e \u0432 2\u20133 \u0440\u0430\u0437\u0430 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0435 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0443\u044e \u043f\u043e\u043a\u0443\u043f\u043d\u0443\u044e \u0446\u0435\u043d\u0443.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 6: \u041a\u0430\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0442 \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u0432 \u0441\u0443\u0440\u043e\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445?<\/strong><\/p>\n\n\n\n<p>\u0414\u043b\u044f \u043c\u0430\u0439\u043d\u0438\u043d\u0433\u0430 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043a\u043e\u0440\u043f\u0443\u0441 \u0441 \u043a\u043b\u0430\u0441\u0441\u043e\u043c \u0437\u0430\u0449\u0438\u0442\u044b \u043d\u0435 \u043d\u0438\u0436\u0435 IP54, \u0430\u043d\u0442\u0438\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043d\u0430\u0433\u0440\u0435\u0432\u0430\u0442\u0435\u043b\u0438, \u0432\u0438\u0431\u0440\u043e\u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 IEC 60068-2-6 \u0438, \u0432 \u0438\u0434\u0435\u0430\u043b\u0435, \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0434\u043b\u044f \u0432\u0437\u0440\u044b\u0432\u043e\u043e\u043f\u0430\u0441\u043d\u043e\u0439 \u0441\u0440\u0435\u0434\u044b (ATEX Ex d \u0438\u043b\u0438 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0439 \u0437\u043d\u0430\u043a MA). \u041b\u0443\u0447\u0448\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438:&nbsp;<strong>XBRELE<\/strong>&nbsp;(\u0421\u0435\u0440\u0438\u044f JCZ \u0441 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u043c MA, \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u0430\u044f \u043d\u0430 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435 \u0432 \u0431\u043e\u043b\u0435\u0435 \u0447\u0435\u043c 200 \u0443\u0433\u043e\u043b\u044c\u043d\u044b\u0445 \u0448\u0430\u0445\u0442\u0430\u0445),&nbsp;<strong>ABB<\/strong>&nbsp;(VM1 \u0441 \u043e\u043f\u0446\u0438\u0435\u0439 IP65, \u0441\u0435\u0439\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f),&nbsp;<strong>\u0418\u0442\u043e\u043d<\/strong>&nbsp;(VCP-W \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u043e\u0442 \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0437\u0440\u044f\u0434\u0430 \u0434\u043b\u044f \u0448\u0430\u0445\u0442 \u0432 \u0421\u0428\u0410). LS Electric \u0438 Schneider \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u044e\u0442 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0434\u043b\u044f \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438, \u043d\u043e \u0441 \u0431\u043e\u043b\u0435\u0435 \u0441\u043b\u0430\u0431\u043e\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0435\u0439 \u0434\u043b\u044f \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c MSHA \u0432 \u0421\u0428\u0410 \u0438\u043b\u0438 MA \u0432 \u041a\u0438\u0442\u0430\u0435. \u0421\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0437\u0431\u0435\u0433\u0430\u0442\u044c \u043e\u0431\u044b\u0447\u043d\u044b\u0445 \u043a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u2014 \u043d\u0435\u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0430\u044f \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043f\u0440\u043e\u043d\u0438\u043a\u0430\u0442\u044c \u043f\u044b\u043b\u0438, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u0431\u043e\u044f\u043c \u0432 \u0440\u0430\u0431\u043e\u0442\u0435 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 18\u201336 \u043c\u0435\u0441\u044f\u0446\u0435\u0432, \u043a\u0430\u043a \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438 \u043d\u0430\u0448\u0438 \u043f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0443\u0433\u043e\u043b\u044c\u043d\u044b\u0445 \u0448\u0430\u0445\u0442\u0430\u0445.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 7: \u041a\u0430\u043a \u043f\u043e\u0441\u0442\u0443\u043f\u0430\u0442\u044c \u0432 \u0441\u043b\u0443\u0447\u0430\u0435 \u0432\u044b\u0445\u043e\u0434\u0430 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0439\u043d\u043e\u0433\u043e \u0441\u0440\u043e\u043a\u0430?<\/strong><\/p>\n\n\n\n<p>\u041d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u0443\u0439\u0442\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043e\u0442\u043a\u0430\u0437\u0430: (1) \u0417\u0430\u043f\u0438\u0448\u0438\u0442\u0435 \u043e\u0431\u0449\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0441\u043e \u0441\u0447\u0435\u0442\u0447\u0438\u043a\u0430 (\u0435\u0441\u043b\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d) \u0438\u043b\u0438 \u043e\u0446\u0435\u043d\u0438\u0442\u0435 \u0438\u0445 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441 \u0434\u0430\u0442\u044b \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0438 \u0442\u0438\u043f\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u0446\u0438\u043a\u043b\u0430; (2) \u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u0435\u0441\u043b\u0438 \u043e\u043d\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e \u2014 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f &gt;500 \u043c\u043a\u041e\u043c \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u0447\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u044b\u0439 \u0438\u0437\u043d\u043e\u0441; (3) \u0421\u0444\u043e\u0442\u043e\u0433\u0440\u0430\u0444\u0438\u0440\u0443\u0439\u0442\u0435 \u0432\u0438\u0434\u0438\u043c\u044b\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f (\u043f\u0435\u0440\u0435\u0433\u043e\u0440\u0435\u0432\u0448\u0438\u0435 \u043a\u043b\u0435\u043c\u043c\u044b, \u0442\u0440\u0435\u0449\u0438\u043d\u044b \u0432 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430\u0445, \u0441\u043b\u0435\u0434\u044b \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432); (4) \u0421\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e (\u043d\u0435 \u0432\u044b\u0431\u0440\u0430\u0441\u044b\u0432\u0430\u0439\u0442\u0435 \u0435\u0433\u043e \u0434\u043e \u043e\u0441\u043c\u043e\u0442\u0440\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c). \u0421\u0432\u044f\u0436\u0438\u0442\u0435\u0441\u044c \u0441\u043e \u0441\u043b\u0443\u0436\u0431\u043e\u0439 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 48 \u0447\u0430\u0441\u043e\u0432 \u2014 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0439 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043d\u0435\u0437\u0430\u043c\u0435\u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0432\u0435\u0434\u043e\u043c\u043b\u0435\u043d\u0438\u044f. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0443\u0440\u043e\u0432\u043d\u044f 1 \u043e\u0431\u044b\u0447\u043d\u043e \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043e\u0432 \u043d\u0430 \u043c\u0435\u0441\u0442\u043e \u0434\u043b\u044f \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0439\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 1 \u043d\u0435\u0434\u0435\u043b\u0438 \u0438 \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u0437\u0430\u0435\u043c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439. \u041a\u0438\u0442\u0430\u0439\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043d\u0430 \u0437\u0430\u0432\u043e\u0434 (\u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u0437\u0430\u043d\u0438\u043c\u0430\u0435\u0442 4\u20138 \u043d\u0435\u0434\u0435\u043b\u044c), \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c\u0443 \u043f\u0440\u043e\u0441\u0442\u043e\u044f, \u0435\u0441\u043b\u0438 \u043d\u0435\u0442 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u043d\u0430 \u0441\u043a\u043b\u0430\u0434\u0435.<\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Selecting a vacuum contactor manufacturer is not a commodity decision. Two contactors rated 12 kV, 400 A, AC-4 can differ by a factor of three in mechanical life, exhibit contact erosion rates varying 40%, and ship with documentation quality ranging from \u201ccomplete type-test certificates\u201d to \u201ctrust us, it works.\u201d These differences surface 18 months [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2388,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25,28],"tags":[],"class_list":["post-2386","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge","category-industry-news"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2386"}],"version-history":[{"count":6,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2386\/revisions"}],"predecessor-version":[{"id":3851,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2386\/revisions\/3851"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2388"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2386"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2386"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}