{"id":2392,"date":"2026-01-02T08:14:43","date_gmt":"2026-01-02T08:14:43","guid":{"rendered":"https:\/\/xbrele.com\/?p=2392"},"modified":"2026-04-07T13:47:09","modified_gmt":"2026-04-07T13:47:09","slug":"capacitor-bank-switching-inrush-pre-insertion","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/capacitor-bank-switching-inrush-pre-insertion\/","title":{"rendered":"\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439: \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435, \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b"},"content":{"rendered":"<p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043f\u0440\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442 20-100\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u0432 \u043f\u0435\u0440\u0432\u043e\u0439 \u043f\u043e\u043b\u043e\u0432\u0438\u043d\u0435 \u0446\u0438\u043a\u043b\u0430, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0435\u0442\u0441\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 5-10 \u043c\u0441, \u0430 \u0437\u0430\u0442\u0435\u043c \u0437\u0430\u0442\u0443\u0445\u0430\u0435\u0442. \u042d\u0442\u0430 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u044e\u0449\u0443\u044e \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c AC-3 \u0438\u043b\u0438 AC-4, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u0432\u0430\u0440\u043a\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u0447\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u043e\u0439 \u044d\u0440\u043e\u0437\u0438\u0438 \u0438 \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u043c\u0443 \u0432\u044b\u0445\u043e\u0434\u0443 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f, \u0435\u0441\u043b\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043d\u0435 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430\u043c\u0438.<\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 \u0443\u0441\u0443\u0433\u0443\u0431\u043b\u044f\u0435\u0442\u0441\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043a\u043e\u0440\u0440\u0435\u043a\u0446\u0438\u0438 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0430 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438, \u0433\u0434\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u044b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0440\u0430\u0437 \u0432 \u0447\u0430\u0441. \u041a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0430\u044f \u0431\u0430\u0442\u0430\u0440\u0435\u044f 12 \u043a\u0412, 5 \u041c\u0412\u0410\u0420, \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u044f\u044e\u0449\u0430\u044f 240 \u0410 \u0432 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u0440\u0435\u0436\u0438\u043c\u0435, \u043c\u043e\u0436\u0435\u0442 \u0433\u0435\u043d\u0435\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043f\u0438\u043a\u043e\u0432\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a 12 \u043a\u0410 \u2014 \u0432 50 \u0440\u0430\u0437 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0439 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u2014 \u0447\u0442\u043e \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043a\u0430\u043a \u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f, \u0442\u0430\u043a \u0438 \u043d\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0437\u0430\u0449\u0438\u0442\u044b, \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u043d\u044b\u0435 \u0432\u044b\u0448\u0435 \u043f\u043e \u0446\u0435\u043f\u0438. \u0411\u0435\u0437 \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0435\u0439 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u043b\u0438\u0431\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0441\u0432\u0430\u0440\u0438\u0432\u0430\u0435\u0442\u0441\u044f, \u043b\u0438\u0431\u043e \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438, \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u043d\u044b\u0435 \u0432\u044b\u0448\u0435 \u043f\u043e \u0446\u0435\u043f\u0438, \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u0431\u0435\u0437 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438, \u0447\u0442\u043e \u0441\u0432\u043e\u0434\u0438\u0442 \u043d\u0430 \u043d\u0435\u0442 \u0446\u0435\u043b\u044c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<p>\u0412 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0430\u0441\u043f\u0435\u043a\u0442\u044b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432, \u0440\u0430\u0441\u0447\u0435\u0442 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u043f\u0435\u0440\u0435\u0434 \u0432\u0441\u0442\u0430\u0432\u043a\u043e\u0439, \u0432\u044b\u0431\u043e\u0440 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430\u043c\u0438 (AC-6b) \u0438 \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0442 \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438: \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0438 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/lkBZRcl1j2g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-capacitor-inrush-exceeds-motor-starting-current\">\u041f\u043e\u0447\u0435\u043c\u0443 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f<\/h2>\n\n\n\n<p>\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u043e\u043c \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u2014 \u043e\u0431\u044b\u0447\u043d\u043e \u043e\u043d \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6\u20138 \u0440\u0430\u0437 \u043e\u0442 \u0442\u043e\u043a\u0430 \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043b\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439 \u0441 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0437\u0430\u043c\u043a\u043d\u0443\u0442\u044b\u043c \u0440\u043e\u0442\u043e\u0440\u043e\u043c. \u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u044f\u0436\u0435\u043d\u043d\u043e\u0433\u043e \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u0438 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u043e\u043c \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u0447\u0442\u043e \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u0438\u0430\u043b\u044c\u043d\u043e \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438.<\/p>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442\u0441\u044f \u043d\u0430 \u0440\u0430\u0437\u0440\u044f\u0436\u0435\u043d\u043d\u0443\u044e \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0443\u044e \u0431\u0430\u0442\u0430\u0440\u0435\u044e, \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043f\u0435\u0440\u0432\u044b\u0445 \u043c\u0438\u043a\u0440\u043e\u0441\u0435\u043a\u0443\u043d\u0434 \u0432\u044b\u0433\u043b\u044f\u0434\u0438\u0442 \u043a\u0430\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435, \u043f\u043e\u043a\u0430 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043d\u0435 \u043d\u0430\u0447\u043d\u0435\u0442 \u043d\u0430\u0440\u0430\u0441\u0442\u0430\u0442\u044c \u043d\u0430 \u0435\u0433\u043e \u043f\u043b\u0430\u0441\u0442\u0438\u043d\u0430\u0445. \u0418\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b (\u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0438, \u043a\u0430\u0431\u0435\u043b\u0438, \u0448\u0438\u043d\u044b) \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043f\u0438\u043a\u043e\u0432\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a:<\/p>\n\n\n\n<p><strong>\u041f\u0438\u043a\u043e\u0432\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a (\u043f\u0435\u0440\u0432\u0430\u044f \u043f\u043e\u043b\u043e\u0432\u0438\u043d\u0430 \u0446\u0438\u043a\u043b\u0430)<\/strong>:<br>I<sub>\u043f\u0438\u043a<\/sub>\u00a0= V<sub>\u0441\u0438\u0441\u0442\u0435\u043c\u0430<\/sub>\u00a0\/ (Z<sub>\u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a<\/sub>\u00a0+ Z<sub>\u043a\u0430\u0431\u0435\u043b\u044c<\/sub>)<br>\u0414\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b 12 \u043a\u0412 \u0441 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u043e\u043c \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 0,5 \u041e\u043c:<br>I<sub>\u043f\u0438\u043a<\/sub>\u00a0= (12 000 \u0412 \u00d7 \u221a2) \/ 0,5 \u041e\u043c \u2248\u00a0<strong>34 \u043a\u0410<\/strong><\/p>\n\n\n\n<p>\u0412 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043f\u0438\u043a\u043e\u0432\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043d\u0438\u0436\u0435 (8\u201315 \u043a\u0410), \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043a\u0430\u0431\u0435\u043b\u044f \u0438 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0434\u043e\u0431\u0430\u0432\u043b\u044f\u044e\u0442 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435. \u041d\u043e \u0434\u0430\u0436\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a 10 \u043a\u0410 \u0432 40\u201350 \u0440\u0430\u0437 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430, \u0447\u0442\u043e \u043d\u0430\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044e \u043f\u0443\u0441\u043a\u0430 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439 AC-4, \u0434\u043b\u044f \u043a\u043e\u0442\u043e\u0440\u043e\u0439 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u0430\u0433\u0430\u0435\u0442\u0441\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0432 6\u20138 \u0440\u0430\u0437 \u0432\u044b\u0448\u0435.<\/p>\n\n\n\n<p><strong>\u0427\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u0439 \u0441\u043e\u0441\u0442\u0430\u0432<\/strong>&nbsp;\u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442\u0441\u044f. \u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0438\u043c\u0435\u0435\u0442 \u043e\u0441\u043d\u043e\u0432\u043d\u0443\u044e \u0447\u0430\u0441\u0442\u043e\u0442\u0443 (50\/60 \u0413\u0446). \u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u0441\u043e\u0434\u0435\u0440\u0436\u0438\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b (500 \u0413\u0446 \u2013 5 \u043a\u0413\u0446) \u043e\u0442 LC-\u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u0430 \u043c\u0435\u0436\u0434\u0443 \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0435\u0439. \u042d\u0442\u0438 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u044e\u0442 \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438 \u043f\u0440\u0438 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u0443\u0441\u043a\u043e\u0440\u044f\u044f \u044d\u0440\u043e\u0437\u0438\u044e.<\/p>\n\n\n\n<p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\">\u043a\u0430\u043a \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0433\u0430\u0441\u044f\u0442 \u0434\u0443\u0433\u0438<\/a>&nbsp;\u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u043f\u043e\u043d\u044f\u0442\u044c, \u043f\u043e\u0447\u0435\u043c\u0443 \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0442\u0440\u0435\u0431\u0443\u044e\u0442\u0441\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u043d\u043e\u0435 \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0434\u043e \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u0443\u0433\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01.webp\" alt=\"\u041e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u043c\u043c\u044b, \u0441\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u044e\u0449\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0441 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u043e\u0439 6\u00d7 \u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u0441 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u043e\u0439 40\u00d7 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u043c\u0438 \u043a\u043e\u043b\u0435\u0431\u0430\u043d\u0438\u044f\u043c\u0438.\" class=\"wp-image-2396\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 1. \u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u043e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u043c\u043c: \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f (\u0432\u0432\u0435\u0440\u0445\u0443) \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043f\u043b\u0430\u0432\u043d\u044b\u0439 \u043f\u0438\u043a 6\u00d7 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 200 \u043c\u0441; \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 (\u0432\u043d\u0438\u0437\u0443) \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043f\u0438\u043a 40\u00d7 \u0441 \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u0435\u043c \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u0430 1 \u043a\u0413\u0446, \u0447\u0442\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c AC-6b.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"utilization-category-ac-6b-what-makes-it-different\">\u041a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f AC-6b: \u0447\u0435\u043c \u043e\u043d\u0430 \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442\u0441\u044f<\/h2>\n\n\n\n<p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-106 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0440\u0435\u0436\u0438\u043c\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f. AC-4 \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u0435\u0442 \u0437\u0430\u043f\u0443\u0441\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f (\u0447\u0430\u0441\u0442\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438, 6-8\u00d7 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a).&nbsp;<strong>AC-6b<\/strong>&nbsp;\u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0441\u0432\u043e\u0438\u043c \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f AC-6b:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c<\/strong>: \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u043e\u043b\u0436\u0435\u043d \u0437\u0430\u043c\u044b\u043a\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0438 \u043f\u0438\u043a\u043e\u0432\u043e\u043c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u043c \u0442\u043e\u043a\u0435 (40-100\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e) \u0431\u0435\u0437 \u043e\u0442\u0441\u043a\u043e\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438\u043b\u0438 \u0441\u0432\u0430\u0440\u043a\u0438.<\/li>\n\n\n\n<li><strong>\u0420\u0430\u0437\u0440\u0443\u0448\u0430\u044e\u0449\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c<\/strong>: \u0414\u043e\u043b\u0436\u0435\u043d \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u043f\u043b\u044e\u0441 \u043b\u044e\u0431\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442<\/li>\n\n\n\n<li><strong>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0443\u0434\u0430\u0440\u0435\u043d\u0438\u0435<\/strong>: \u041a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u044b \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044e\u0442 \u0437\u0430\u0440\u044f\u0434 \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f; TRV (\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430) \u043c\u043e\u0436\u0435\u0442 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0442\u044c 2,0 \u0435\u0434. \u043f\u0440\u043e\u0442\u0438\u0432 1,4 \u0435\u0434. \u0434\u043b\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f.<\/li>\n<\/ul>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 120 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b AC-4 \u0432\u044b\u0445\u043e\u0434\u044f\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 500-2000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0438\u0437-\u0437\u0430 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c AC-6b, \u0432 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0441\u043f\u043b\u0430\u0432 CuCr25 (\u0441 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435\u043c \u0445\u0440\u043e\u043c\u0430), \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 10 000-30 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u0435\u0440\u0435\u0434 \u0437\u0430\u043c\u0435\u043d\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432.<\/p>\n\n\n\n<p><strong>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u0437\u0430\u0437\u043e\u0440<\/strong>&nbsp;\u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0432 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u0445 AC-6b: 12\u201314 \u043c\u043c \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 8\u201310 \u043c\u043c \u0434\u043b\u044f AC-4. \u0411\u043e\u043b\u044c\u0448\u0438\u0439 \u0437\u0430\u0437\u043e\u0440 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0431\u043e\u043b\u044c\u0448\u0435\u0435 \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0434\u043e \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u0443\u0433\u0438, \u0447\u0442\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043f\u0438\u043a\u043e\u0432\u0443\u044e \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c \u0442\u043e\u043a\u0430 \u043f\u0440\u0438 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u0438 \u0434\u0443\u0433\u0438. \u042d\u0442\u043e \u0437\u0430 \u0441\u0447\u0435\u0442 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0437\u0430\u0449\u0438\u0442\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u0447\u0442\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u044b\u043c, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u044b \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u043a\u0430\u043a \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438.<\/p>\n\n\n\n<p><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0441\u0443\u0440\u0441 AC-6b (\u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-106)<\/strong>:<br>\u2022 12 \u043a\u0412, 200 \u0410, \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430:\u00a0<strong>10 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/strong><br>\u2022 12 \u043a\u0412, 400 \u0410, \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430:\u00a0<strong>8000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/strong><br>\u2022 24 \u043a\u0412, 200 \u0410, \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0430\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430:\u00a0<strong>6000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/strong><br>\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435 \u0441 \u0440\u0430\u0431\u043e\u0447\u0438\u043c \u0446\u0438\u043a\u043b\u043e\u043c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f AC-4: 10 000\u201315 000 \u0446\u0438\u043a\u043b\u043e\u0432 \u043f\u0440\u0438 \u0442\u0435\u0445 \u0436\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u0445.<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u0432\u0441\u0435\u0441\u0442\u043e\u0440\u043e\u043d\u043d\u0435\u0433\u043e \u043f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u044f&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/capacitor-duty-contactor-failure-modes-switching\/\">\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0442\u0438\u043f\u0430<\/a>, \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u043c\u0438 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0438 \u0444\u0438\u043b\u044c\u0442\u0440\u0430\u0446\u0438\u0438 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"pre-insertion-resistors-physics-and-sizing\">\u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0432\u0441\u0442\u0430\u0432\u043a\u0438: \u0444\u0438\u0437\u0438\u043a\u0430 \u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u044b<\/h2>\n\n\n\n<p>\u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0432\u0441\u0442\u0430\u0432\u043a\u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u043c \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u043e \u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f. \u0427\u0435\u0440\u0435\u0437 10\u201350 \u043c\u0441 (\u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u043d\u0430\u0441\u0442\u0440\u0430\u0438\u0432\u0430\u0435\u0442\u0441\u044f) \u043e\u0431\u0445\u043e\u0434\u043d\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440, \u0443\u0434\u0430\u043b\u044f\u044f \u0435\u0433\u043e \u0438\u0437 \u0446\u0435\u043f\u0438.<\/p>\n\n\n\n<p><strong>\u0411\u0430\u0437\u043e\u0432\u0430\u044f \u0441\u0445\u0435\u043c\u0430<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0413\u043b\u0430\u0432\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442\u0441\u044f \u0441 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u043c \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u043e\u043c<\/li>\n\n\n\n<li>\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u0439 R: I = V \/ (Z_source + R)<\/li>\n\n\n\n<li>\u0420\u0435\u043b\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u043e\u0436\u0438\u0434\u0430\u0435\u0442 10-50 \u043c\u0441 (\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440 \u0437\u0430\u0440\u044f\u0436\u0430\u0435\u0442\u0441\u044f \u0434\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f ~95%)<\/li>\n\n\n\n<li>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0431\u0430\u0439\u043f\u0430\u0441\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442\u0441\u044f, \u0437\u0430\u043c\u044b\u043a\u0430\u044f \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440<\/li>\n\n\n\n<li>\u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440 \u043d\u0435 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442 \u0442\u043e\u043a \u043f\u0440\u0438 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u0435<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0424\u043e\u0440\u043c\u0443\u043b\u0430 \u0440\u0430\u0441\u0447\u0435\u0442\u0430 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430<\/strong>:<br>R = (V<sub>\u043f\u0438\u043a<\/sub>&nbsp;\u2013 V<sub>\u0448\u0430\u043f\u043a\u0430,\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f<\/sub>) \/ I<sub>\u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u043c\u0430\u043a\u0441.<\/sub><br>\u0414\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b 12 \u043a\u0412, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0434\u043e 2 \u043a\u0410:<br>R = (16 970 \u0412 \u2013 0 \u0412) \/ 2000 \u0410 \u2248&nbsp;<strong>8,5 \u041e\u043c<\/strong><\/p>\n\n\n\n<p><strong>\u0420\u0430\u0441\u0441\u0435\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c (\u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f)<\/strong>:<br>P = I\u00b2 \u00d7 R \u00d7 \u0432\u0440\u0435\u043c\u044f<br>\u0414\u043b\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 2 \u043a\u0410, \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c 20 \u043c\u0441:<br>\u042d\u043d\u0435\u0440\u0433\u0438\u044f = (2000)\u00b2 \u00d7 8,5 \u00d7 0,020 =\u00a0<strong>680 \u043a\u0414\u0436<\/strong><br>\u0422\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0432\u044b\u0441\u043e\u043a\u043e\u043c\u043e\u0449\u043d\u044b\u0439 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440 (\u043a\u0440\u0443\u0442\u0438\u043b\u044c\u043d\u044b\u0439 \u0438\u043b\u0438 \u0440\u0435\u0448\u0435\u0442\u0447\u0430\u0442\u044b\u0439).<\/p>\n\n\n\n<p><strong>\u041f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440 \u0434\u043e\u043b\u0436\u0435\u043d \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0442\u0435\u0440\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0434\u0430\u0440 (\u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u2192 300 \u00b0C \u0437\u0430 20 \u043c\u0441)<\/li>\n\n\n\n<li>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0431\u0430\u0439\u043f\u0430\u0441\u0430 \u0434\u043e\u043b\u0436\u0435\u043d \u043d\u0430\u0434\u0435\u0436\u043d\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u0442\u044c\u0441\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 10\u201350 \u043c\u0441.<\/li>\n\n\n\n<li>\u0420\u0435\u0436\u0438\u043c \u043e\u0442\u043a\u0430\u0437\u0430 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c \u0446\u0435\u043f\u0438 (\u043d\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c), \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043d\u0435\u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0433\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/li>\n<\/ul>\n\n\n\n<p>\u0412 \u043d\u0430\u0448\u0438\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445, \u043d\u0430\u0441\u0447\u0438\u0442\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u0431\u043e\u043b\u0435\u0435 80 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439, \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0432\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u043b\u043e \u044d\u0440\u043e\u0437\u0438\u044e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043d\u0430 60-70% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0440\u044f\u043c\u044b\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c, \u043f\u0440\u043e\u0434\u043b\u0438\u0432 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0441 3000 \u0434\u043e 12 000+ \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02.webp\" alt=\"\u0421\u0445\u0435\u043c\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u043f\u0435\u0440\u0435\u0434 \u0432\u0441\u0442\u0430\u0432\u043a\u043e\u0439, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0433\u043b\u0430\u0432\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440, \u043e\u0431\u0445\u043e\u0434\u043d\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u0443\u044e \u0431\u0430\u0442\u0430\u0440\u0435\u044e \u0441 \u0430\u043d\u043d\u043e\u0442\u0430\u0446\u0438\u044f\u043c\u0438 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u0438\" class=\"wp-image-2395\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 2. \u0426\u0435\u043f\u044c \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u043f\u0435\u0440\u0435\u0434 \u0432\u0441\u0442\u0430\u0432\u043a\u043e\u0439 \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0441 34 \u043a\u0410 (\u043f\u0440\u044f\u043c\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435) \u0434\u043e 2 \u043a\u0410 (\u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u0439). \u0413\u043b\u0430\u0432\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442\u0441\u044f \u0441 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u043e\u043c 8,5 \u041e\u043c; \u043f\u043e\u0441\u043b\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 20 \u043c\u0441 \u0431\u0430\u0439\u043f\u0430\u0441\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440 \u0434\u043b\u044f \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"back-to-back-switching-and-resonance-risk\">\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u00ab\u0441\u043f\u0438\u043d\u0430 \u043a \u0441\u043f\u0438\u043d\u0435\u00bb \u0438 \u0440\u0438\u0441\u043a \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u0430<\/h2>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u043d\u0430 \u043e\u0434\u043d\u043e\u0439 \u0448\u0438\u043d\u0435, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043e\u0434\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u043f\u0440\u0438 \u0442\u043e\u043c, \u0447\u0442\u043e \u0434\u0440\u0443\u0433\u0438\u0435 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c, \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u201c\u0441\u043f\u0438\u043d\u0430 \u043a \u0441\u043f\u0438\u043d\u0435\u201d. \u0411\u0430\u0442\u0430\u0440\u0435\u0438, \u043d\u0430\u0445\u043e\u0434\u044f\u0449\u0438\u0435\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0442 \u043a\u0430\u043a \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0441 \u043d\u0438\u0437\u043a\u0438\u043c \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u043e\u043c, \u0432\u044b\u0437\u044b\u0432\u0430\u044f \u043c\u0430\u0441\u0441\u0438\u0432\u043d\u044b\u0439 \u0432\u0441\u043f\u043b\u0435\u0441\u043a \u0442\u043e\u043a\u0430 \u0432 \u0442\u043e\u043b\u044c\u043a\u043e \u0447\u0442\u043e \u0437\u0430\u043c\u043a\u043d\u0443\u0442\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0435.<\/p>\n\n\n\n<p><strong>\u0421\u0442\u0435\u043f\u0435\u043d\u044c \u0442\u044f\u0436\u0435\u0441\u0442\u0438 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0445 \u0442\u043e\u043a\u043e\u0432<\/strong>:<br>\u041f\u0440\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 3 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 (\u043e\u0431\u0449\u0435\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c\u044e 15 \u041c\u0412\u0410\u0420) \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 4-\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 (5 \u041c\u0412\u0410\u0420) \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u043c\u0443 \u0442\u043e\u043a\u0443, \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u043c\u0443:<br>Z<sub>\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0439<\/sub>\u00a0= (\u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043a\u0430\u0431\u0435\u043b\u044f) \u0442\u043e\u043b\u044c\u043a\u043e \u2014 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u044b \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u044e\u0442 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430.<br>\u0420\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442: \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043c\u043e\u0436\u0435\u0442 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0442\u044c\u00a0<strong>100\u2013200\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/strong>\u00a0\u043f\u0440\u043e\u0442\u0438\u0432 20-40\u00d7 \u0434\u043b\u044f \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u0441\u043c\u044f\u0433\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u0439<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439<\/strong>: \u041f\u043e\u043e\u0447\u0435\u0440\u0435\u0434\u043d\u043e \u0430\u043a\u0442\u0438\u0432\u0438\u0440\u0443\u0439\u0442\u0435 \u0431\u0430\u043d\u043a\u0438 \u0441 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u043e\u043c 30-60 \u0441\u0435\u043a\u0443\u043d\u0434, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044f \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u043c \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430\u043c \u0437\u0430\u0442\u0443\u0445\u0430\u0442\u044c.<\/li>\n\n\n\n<li><strong>\u0420\u0435\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0438<\/strong>: \u0421\u0435\u0440\u0438\u0439\u043d\u0430\u044f \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c (\u043e\u0431\u044b\u0447\u043d\u043e 5-7%) \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0437\u0430 \u0441\u0447\u0435\u0442 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044f \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u0430.<\/li>\n\n\n\n<li><strong>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u043e\u0435 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435<\/strong>: \u0417\u0430\u043c\u043a\u043d\u0438\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0438 \u043d\u0443\u043b\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0447\u0442\u043e\u0431\u044b \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0440\u0430\u0437\u043d\u043e\u0441\u0442\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439 \u043d\u0430 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0435.<\/li>\n<\/ol>\n\n\n\n<p>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 40 \u043c\u043d\u043e\u0433\u043e\u0431\u0430\u043d\u043a\u043e\u0432\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438, \u0447\u0442\u043e \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0441\u043d\u0438\u0436\u0430\u044e\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043d\u0430 50-70% (\u0441 150\u00d7 \u0434\u043e 45-60\u00d7), \u0447\u0442\u043e \u0438\u043c\u0435\u0435\u0442 \u0440\u0435\u0448\u0430\u044e\u0449\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u043f\u0440\u043e\u0434\u043b\u0435\u043d\u0438\u044f \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0432 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 PFC.<\/p>\n\n\n\n<p><strong>\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441<\/strong>&nbsp;\u0440\u0438\u0441\u043a\u0438 \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u044e\u0442, \u043a\u043e\u0433\u0434\u0430 \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u0430 L \u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 C \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441 \u0432\u0431\u043b\u0438\u0437\u0438 \u0447\u0430\u0441\u0442\u043e\u0442 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u0441\u0435\u0442\u0438 (5-\u044f, 7-\u044f, 11-\u044f). \u0414\u043b\u044f \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0430\u0441\u0447\u0435\u0442\u0430 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0441\u0442\u0438 \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0420\u0435\u0430\u043a\u0442\u043e\u0440 5.67% \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441 \u043f\u0440\u0438 4,2\u00d7 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u0435 (\u043c\u0435\u0436\u0434\u0443 4-\u0439 \u0438 5-\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u043e\u0439)<\/li>\n\n\n\n<li>\u0420\u0435\u0430\u043a\u0442\u043e\u0440 7% \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441 \u043f\u0440\u0438 3,8\u00d7 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u0435 (\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u044b\u0439 \u0437\u0430\u043f\u0430\u0441 \u043d\u0438\u0436\u0435 5-\u0439).<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03.webp\" alt=\"\u0412\u0435\u043a\u0442\u043e\u0440\u043d\u0430\u044f \u0434\u0438\u0430\u0433\u0440\u0430\u043c\u043c\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f, \u043a\u0430\u043a \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u044e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0441 40 \u0434\u043e 200 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430.\" class=\"wp-image-2394\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 3. \u0421\u0446\u0435\u043d\u0430\u0440\u0438\u0439 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f: \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u0435 \u0431\u0430\u043d\u043a\u0438 (15 \u041c\u0412\u0410\u0440) \u0441\u043d\u0438\u0436\u0430\u044e\u0442 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u0441 0,5 \u041e\u043c \u0434\u043e \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u043a\u0430\u0431\u0435\u043b\u044f (0,02 \u041e\u043c), \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0441 40 \u0434\u043e 200 \u0440\u0430\u0437 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0442\u043e\u043a\u043e\u043c.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-coordination-fuses-vs-relays\">\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b: \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 \u0438 \u0440\u0435\u043b\u0435<\/h2>\n\n\n\n<p>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0434\u043e\u043b\u0436\u043d\u0430 \u0440\u0430\u0437\u043b\u0438\u0447\u0430\u0442\u044c:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041f\u0443\u0441\u043a\u043e\u0432\u044b\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u044b<\/strong>\u00a0(20\u2013100\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435, \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c 5\u201320 \u043c\u0441) \u2014 \u043d\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0442\u044c<\/li>\n\n\n\n<li><strong>\u0412\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430<\/strong>\u00a0(\u0440\u0430\u0437\u0440\u044b\u0432, \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0440\u043e\u0431\u043e\u0439) \u2014 \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435<\/li>\n\n\n\n<li><strong>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432<\/strong>\u00a0(\u0441\u0432\u0430\u0440\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u0437\u0430\u0441\u0442\u0440\u044f\u043b\u0438 \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438) \u2014 \u0441\u0438\u0433\u043d\u0430\u043b \u0442\u0440\u0435\u0432\u043e\u0433\u0438\/\u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439<\/strong>&nbsp;(\u043e\u0431\u044b\u0447\u043d\u043e \u0434\u043b\u044f \u0431\u0430\u043d\u043a\u043e\u0432 &lt;5 MVAR):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u0442\u043e\u043a\u0430, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 1,5\u20132,0\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430.<\/li>\n\n\n\n<li>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 I\u00b2t \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f \u0434\u043e\u043b\u0436\u043d\u043e \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e:\n<ul class=\"wp-block-list\">\n<li>\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a I\u00b2t = (40 \u00d7 I_rated)\u00b2 \u00d7 0,010 \u0441<\/li>\n\n\n\n<li>\u0414\u043b\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 200 \u0410: I\u00b2t = 64 000 A\u00b2s<\/li>\n\n\n\n<li>\u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c \u0441 I\u00b2t &gt;100 000 A\u00b2s, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0440\u0435\u043b\u0435<\/strong>&nbsp;(&gt;5 \u041c\u0412\u0410 \u0438\u043b\u0438 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0440\u0435\u043b\u0435 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443 \u0441 \u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 (0,5\u20131,0 \u0441) \u0434\u043b\u044f \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u043d\u0438\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/li>\n\n\n\n<li>\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 1,3\u20131,5\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a (\u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a + \u0434\u043e\u043f\u0443\u0441\u043a)<\/li>\n\n\n\n<li>\u0412\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a (\u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 2-\u0439\/3-\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438), \u0435\u0441\u043b\u0438 \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e<\/li>\n<\/ul>\n\n\n\n<p>\u041c\u044b \u0438\u0437\u043c\u0435\u0440\u0438\u043b\u0438 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u043d\u0430 30% \u043f\u043e\u0441\u043b\u0435 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0440\u043e\u0441\u0442\u044b\u043c\u0438 \u0440\u0435\u043b\u0435 \u0441 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u043d\u0430 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f\u0445 \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u043c\u0438 \u0431\u0430\u0442\u0430\u0440\u0435\u044f\u043c\u0438 15-20 \u041c\u0412\u0410\u0440, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u043c\u0438\u0441\u044f 4-6 \u0440\u0430\u0437 \u0432 \u0447\u0430\u0441.<\/p>\n\n\n\n<p><strong>\u041f\u0440\u0438\u043c\u0435\u0440 \u043d\u0430\u0441\u0442\u0440\u043e\u0435\u043a \u0440\u0435\u043b\u0435 (\u0440\u0435\u043b\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f SEL-751, \u0431\u0430\u043d\u043a 12 \u043a\u0412 5 \u041c\u0412\u0410\u0440, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a 240 \u0410)<\/strong>:<br><code>50P1 = \u0412\u042b\u041a\u041b.<\/code>\u00a0(\u043e\u0442\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e\u0435)<br><code>51P1 = 1,4 \u00d7 240 = 336 \u0410<\/code>\u00a0(\u0437\u0430\u0431\u043e\u0440)<br><code>51TD1 = 1,0 \u0441<\/code>\u00a0(\u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0434\u043b\u044f \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430)<br><code>50H1 = 20%<\/code>\u00a0(\u043f\u043e\u0440\u043e\u0433 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contactor-selection-checklist-for-capacitor-duty\">\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0434\u043b\u044f \u0432\u044b\u0431\u043e\u0440\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430\u043c\u0438<\/h2>\n\n\n\n<p>\u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 AC-6b \u2014 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f AC-4 \u0432\u044b\u0439\u0434\u0443\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e. \u0412\u043e\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435\u0441\u044c \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u043c \u0441\u043f\u0438\u0441\u043a\u043e\u043c:<\/p>\n\n\n\n<p><strong>1. \u041f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044e AC-6b<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0417\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEC 62271-106, \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0449\u0438\u0439 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u043d\u0430 \u0440\u0430\u0431\u043e\u0442\u043e\u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c.<\/li>\n\n\n\n<li>\u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438 \u0442\u043e\u043a \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044e (12 \u043a\u0412, 400 \u0410 \u0438 \u0442. \u0434.).<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f: \u043c\u0438\u043d\u0438\u043c\u0443\u043c 8000 \u0446\u0438\u043a\u043b\u043e\u0432 \u0434\u043b\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e PFC.<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u0420\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u0439\u0442\u0435 \u0442\u043e\u043a \u0432 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u0440\u0435\u0436\u0438\u043c\u0435.<\/strong><br>I<sub>\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440<\/sub>\u00a0= Q<sub>MVAR<\/sub>\u00a0\/ (\u221a3 \u00d7 V<sub>\u0441\u0442\u0440\u043e\u043a\u0430 \u0437\u0430 \u0441\u0442\u0440\u043e\u043a\u043e\u0439<\/sub>)<br>\u041f\u0440\u0438\u043c\u0435\u0440: 5 \u041c\u0412\u0410\u0440 \u043f\u0440\u0438 12 \u043a\u0412<br>I = 5 000 000 \/ (1,732 \u00d7 12 000) =\u00a0<strong>240 \u0410<\/strong><br>\u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c \u22651,35\u00d7 \u0440\u0430\u0441\u0447\u0435\u0442\u043d\u044b\u0439 \u0442\u043e\u043a =\u00a0<strong>325 \u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439<\/strong><\/p>\n\n\n\n<p><strong>3. \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u0443\u044e \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0412 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u0443\u043a\u0430\u0437\u0430\u043d \u043f\u0438\u043a\u043e\u0432\u044b\u0439 \u0442\u043e\u043a \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043b\u044f AC-6b.<\/li>\n\n\n\n<li>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 AC-6b \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u0432 40-60 \u0440\u0430\u0437 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0439 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439.<\/li>\n\n\n\n<li>\u0414\u043b\u044f \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439 \u0440\u0430\u0431\u043e\u0442\u044b (\u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a &gt;60\u00d7) \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0443\u043a\u0430\u0437\u0430\u0442\u044c \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f, \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u043f\u0435\u0440\u0435\u0434 \u0432\u0441\u0442\u0430\u0432\u043a\u043e\u0439.<\/li>\n<\/ul>\n\n\n\n<p><strong>4. \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0414\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e NO\/NC-\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043e\u043a \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f (\u043e\u0431\u044b\u0447\u043d\u043e \u043c\u0438\u043d\u0438\u043c\u0443\u043c 4 NO + 2 NC)<\/li>\n\n\n\n<li>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0446\u0435\u043f\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f (110 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, 220 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438 \u0442. \u0434.)<\/li>\n\n\n\n<li>\u0421\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432: 100 000\u2013300 000 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/li>\n<\/ul>\n\n\n\n<p><strong>5. \u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0438<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0412 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0438: \u043c\u0438\u043d\u0438\u043c\u0443\u043c IP20; \u043d\u0430 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0432\u043e\u0437\u0434\u0443\u0445\u0435: \u043c\u0438\u043d\u0438\u043c\u0443\u043c IP54<\/li>\n\n\n\n<li>\u041a\u043e\u0440\u0440\u0435\u043a\u0446\u0438\u044f \u0432\u044b\u0441\u043e\u0442\u044b, \u0435\u0441\u043b\u0438 &gt;1000 \u043c (\u0440\u0430\u0437\u0440\u044b\u0432\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0442\u044c\u0441\u044f)<\/li>\n\n\n\n<li>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440: \u043e\u0442 -25 \u00b0C \u0434\u043e +40 \u00b0C \u0432 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u0439 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442\u0430\u0446\u0438\u0438, \u0440\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u043d\u044b\u0439 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0434\u043b\u044f \u044d\u043a\u0441\u0442\u0440\u0435\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043b\u0438\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439<\/li>\n<\/ul>\n\n\n\n<p>\u041f\u043e\u0434\u0440\u043e\u0431\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0441\u043c. \u0432&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/\">\u043f\u0435\u0440\u0435\u0447\u043d\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043e\u043a \u043f\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e \u0438 \u0438\u043d\u0441\u043f\u0435\u043a\u0446\u0438\u0438<\/a>&nbsp;\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c AC-6b, \u0438 \u0441\u0432\u0435\u0440\u044c\u0442\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u044b \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0441 \u044d\u0442\u0438\u043c&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/medium-voltage-vacuum-contactor-guide\/\">\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430\u043c \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04.webp\" alt=\"\u0411\u043b\u043e\u043a-\u0441\u0445\u0435\u043c\u0430 \u0432\u044b\u0431\u043e\u0440\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0434\u043b\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a AC-6b, \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u043f\u043e \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u0435\" class=\"wp-image-2393\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 4. \u0411\u043b\u043e\u043a-\u0441\u0445\u0435\u043c\u0430 \u0432\u044b\u0431\u043e\u0440\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u0434\u043b\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438, \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0443 \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u00ab\u0441\u043f\u0438\u043d\u0430 \u043a \u0441\u043f\u0438\u043d\u0435\u00bb, \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u043e\u0441\u0442\u044c \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u043e\u0432 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043a\u043e\u043c\u043f\u0440\u043e\u043c\u0438\u0441\u0441\u044b \u043f\u043e \u0441\u0440\u043e\u043a\u0443 \u0441\u043b\u0443\u0436\u0431\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0441 \u0440\u0435\u0436\u0438\u043c\u043e\u043c \u0440\u0430\u0431\u043e\u0442\u044b AC-6b.<\/figcaption><\/figure>\n\n\n\n<p><strong>\u0412\u043d\u0435\u0448\u043d\u044f\u044f \u0441\u0441\u044b\u043b\u043a\u0430:<\/strong> \u041a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u044b \u0432&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">\u041c\u042d\u041a 62271-106<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-and-end-of-life-indicators\">\u0418\u043d\u0434\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u043e\u043a\u043e\u043d\u0447\u0430\u043d\u0438\u044f \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b<\/h2>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0431\u044b\u0441\u0442\u0440\u0435\u0435, \u0447\u0435\u043c \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439, \u0438\u0437-\u0437\u0430 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438. \u0421\u043b\u0435\u0434\u0438\u0442\u0435 \u0437\u0430 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u043c\u0438 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044f\u043c\u0438:<\/p>\n\n\n\n<p><strong>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u0430\u044f \u044d\u0440\u043e\u0437\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0437\u043c\u0435\u0440\u044f\u0439\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u043a\u0430\u0436\u0434\u044b\u0435 2000\u20133000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 5000 \u0434\u043b\u044f AC-4).<\/li>\n\n\n\n<li>\u0417\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u0435\u0441\u043b\u0438 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 500 \u043c\u043a\u041e\u043c (\u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u043e\u0432\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043e\u0431\u044b\u0447\u043d\u043e \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 100\u2013200 \u043c\u043a\u041e\u043c).<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0445 \u0441\u0432\u0430\u0440\u043d\u044b\u0445 \u0448\u0432\u043e\u0432<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u043e\u0441\u043b\u0435 \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0443\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438 \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u0435\u0442\u0441\u044f.<\/li>\n\n\n\n<li>\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0434\u043b\u044f \u043f\u043e\u0434\u0430\u0447\u0438 \u0441\u0438\u0433\u043d\u0430\u043b\u0430 \u0442\u0440\u0435\u0432\u043e\u0433\u0438, \u0435\u0441\u043b\u0438 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0437\u0430\u043c\u043a\u043d\u0443\u0442\u044b\u043c\u0438 \u043f\u0440\u0438 \u043e\u0431\u0435\u0441\u0442\u043e\u0447\u0438\u0432\u0430\u043d\u0438\u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0438.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0442\u043e\u043a\u0430 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u0440\u0435\u0436\u0438\u043c\u0435<\/li>\n\n\n\n<li>\u0422\u0435\u043a\u0443\u0449\u0435\u0435 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 &gt;10% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0431\u0430\u0437\u043e\u0432\u044b\u043c \u0443\u0440\u043e\u0432\u043d\u0435\u043c \u043f\u0440\u0438 \u0432\u0432\u043e\u0434\u0435 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u0438\u043b\u0438 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441.<\/li>\n<\/ul>\n\n\n\n<p>\u0412 \u0445\u043e\u0434\u0435 \u043d\u0430\u0448\u0435\u0433\u043e 5-\u043b\u0435\u0442\u043d\u0435\u0433\u043e \u043f\u043e\u043b\u0435\u0432\u043e\u0433\u043e \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430 200 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439, \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b AC-6b \u0441 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c \u0434\u043e\u0441\u0442\u0438\u0433\u043b\u0438 12 000\u201318 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0434\u043e \u0437\u0430\u043c\u0435\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 3000\u20135000 \u0434\u043b\u044f \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 AC-4. \u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b, \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u0434 \u0432\u0441\u0442\u0430\u0432\u043a\u043e\u0439, \u043f\u0440\u043e\u0434\u043b\u0438\u043b\u0438 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0434\u043e 20 000+ \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0432 \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u043e\u0439 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\n\n\n\n<p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u2014 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0432\u044b\u0445\u043e\u0434\u044f\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043f\u043e\u0434 \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435\u043c \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 20\u2013100\u00d7 \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0445 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0432. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c AC-6b, \u0432 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0443\u0441\u043e\u0432\u0435\u0440\u0448\u0435\u043d\u0441\u0442\u0432\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u043d\u044b\u0435 \u0437\u0430\u0437\u043e\u0440\u044b \u043f\u0435\u0440\u0435\u0434 \u0434\u0443\u0433\u043e\u0439, \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u044e\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0434\u043e 8000\u201315 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439, \u043d\u043e \u0442\u043e\u043b\u044c\u043a\u043e \u0432 \u0442\u043e\u043c \u0441\u043b\u0443\u0447\u0430\u0435, \u0435\u0441\u043b\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/p>\n\n\n\n<p>\u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b, \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u0434 \u0432\u0432\u043e\u0434\u043e\u043c, \u0441\u043c\u044f\u0433\u0447\u0430\u044e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u043a\u043e\u0433\u0434\u0430 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u043f\u0438\u043a\u0438 &gt;60\u00d7, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0432 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043c\u043d\u043e\u0433\u043e\u0431\u0430\u043d\u043a\u043e\u0432\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445. \u0420\u0435\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u0432\u0443\u043c \u0446\u0435\u043b\u044f\u043c: \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044e \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u0430, \u0445\u043e\u0442\u044f \u0434\u043b\u044f \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0442\u0449\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044f \u043d\u043e\u0432\u044b\u0445 \u0442\u043e\u0447\u0435\u043a \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u0430.<\/p>\n\n\n\n<p>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0434\u043e\u043b\u0436\u043d\u0430 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0442\u044c \u0431\u0430\u043b\u0430\u043d\u0441 \u043c\u0435\u0436\u0434\u0443 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c\u044e \u043a \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u043c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u043c \u0438 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c\u044e \u043a \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u043c \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430\u043c. \u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u043d\u0430\u0434\u0435\u0436\u043d\u044b\u043c \u0440\u0435\u0448\u0435\u043d\u0438\u0435\u043c \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043a\u043e\u0440\u0440\u0435\u043a\u0446\u0438\u0438 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0430 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u0445\u0441\u044f 4\u20136 \u0440\u0430\u0437 \u0432 \u0447\u0430\u0441. \u0417\u0430\u0449\u0438\u0442\u0430 \u0442\u043e\u043b\u044c\u043a\u043e \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439 \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043f\u0440\u043e\u0441\u0442\u043e\u0433\u043e \u0440\u0443\u0447\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043e\u0434\u043d\u043e\u0433\u043e \u0440\u044f\u0434\u0430, \u043d\u043e \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043f\u043e\u043c\u0435\u0445\u0438 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441 \u0447\u0430\u0441\u0442\u044b\u043c \u0440\u0435\u0436\u0438\u043c\u043e\u043c \u0440\u0430\u0431\u043e\u0442\u044b.<\/p>\n\n\n\n<p>\u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430, \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u043f\u0440\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0438 \u0441\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u0437\u0430\u0449\u0438\u0442\u0430 \u043f\u0440\u0435\u0432\u0440\u0430\u0449\u0430\u044e\u0442 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0438\u0437 \u0445\u0440\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0432 \u043d\u0430\u0434\u0435\u0436\u043d\u0443\u044e \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u0444\u0443\u043d\u043a\u0446\u0438\u044e, \u0441\u043d\u0438\u0436\u0430\u044f \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0440\u0435\u0430\u043a\u0442\u0438\u0432\u043d\u0443\u044e \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044f \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u0441\u0432\u0430\u0440\u043a\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u044d\u0440\u043e\u0437\u0438\u0438 \u0438 \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u043e\u0442\u043a\u0430\u0437\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u043e\u0439 \u0434\u043b\u044f \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u043e\u0431\u0440\u0430\u043d\u043d\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-capacitor-bank-switching\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b: \u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u044b\u0445 \u0431\u0430\u0442\u0430\u0440\u0435\u0439<\/h2>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 1: \u041f\u043e\u0447\u0435\u043c\u0443 \u043d\u0435\u043b\u044c\u0437\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f AC-4 \u0434\u043b\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430?<\/strong><\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f (AC-4) \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u044b \u043d\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a 6-8\u00d7 \u043f\u0440\u0438 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u0435 (50\/60 \u0413\u0446). \u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442 20-100\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0447\u0430\u0441\u0442\u043e\u0442\u043d\u044b\u043c\u0438 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u0430\u043c\u0438 (500 \u0413\u0446 \u2013 5 \u043a\u0413\u0446), \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u043a\u043e\u043d\u0446\u0435\u043d\u0442\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0434\u0443\u0433\u0438, \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0443\u044e \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u0435 \u043f\u0440\u0435\u0434\u0435\u043b\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432 AC-4. \u041f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442, \u0447\u0442\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b AC-4 \u0432\u044b\u0445\u043e\u0434\u044f\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f \u043f\u043e\u0441\u043b\u0435 500-2000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 8000-15000 \u0434\u043b\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 AC-6b. \u0420\u0435\u0436\u0438\u043c \u043e\u0442\u043a\u0430\u0437\u0430 \u2014 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u043d\u0430\u044f \u044d\u0440\u043e\u0437\u0438\u044f \u0438 \u0441\u0432\u0430\u0440\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b AC-4 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0441\u043f\u043b\u0430\u0432 CuCr15-20, \u043e\u043f\u0442\u0438\u043c\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0434\u043b\u044f \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a AC-6b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 CuCr25 \u0441 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435\u043c \u0445\u0440\u043e\u043c\u0430 \u0434\u043b\u044f \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0445 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0432 \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u0442\u044c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u0432\u0441\u0442\u0430\u0432\u043a\u043e\u0439?<\/strong><\/p>\n\n\n\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 R = V_peak \/ I_inrush_max, \u0433\u0434\u0435 V_peak = \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u00d7 \u221a2 (\u0434\u043b\u044f 12 \u043a\u0412: 16 970 \u0412), \u0430 I_inrush_max \u2014 \u044d\u0442\u043e \u0432\u0430\u0448 \u0446\u0435\u043b\u0435\u0432\u043e\u0439 \u043f\u0440\u0435\u0434\u0435\u043b (\u043e\u0431\u044b\u0447\u043d\u043e 1,5\u20132,5 \u043a\u0410). \u041f\u0440\u0438\u043c\u0435\u0440: \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 12 \u043a\u0412 \u0434\u043e 2 \u043a\u0410 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f R = 16 970 \/ 2000 \u2248 8,5 \u041e\u043c. \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0434\u043e\u043b\u0436\u043d\u0430 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0443\u044e \u044d\u043d\u0435\u0440\u0433\u0438\u044e: E = I\u00b2 \u00d7 R \u00d7 \u0432\u0440\u0435\u043c\u044f. \u0414\u043b\u044f 2 \u043a\u0410, 20 \u043c\u0441: E = (2000)\u00b2 \u00d7 8,5 \u00d7 0,020 = 680 \u043a\u0414\u0436. \u0423\u043a\u0430\u0436\u0438\u0442\u0435 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0435 \u0438\u043b\u0438 \u0440\u0435\u0448\u0435\u0442\u0447\u0430\u0442\u044b\u0435 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u0443\u0434\u0430\u0440 (\u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0430\u044f \u0441\u0440\u0435\u0434\u0430 \u2192 300 \u00b0C \u0437\u0430 \u043c\u0438\u043b\u043b\u0438\u0441\u0435\u043a\u0443\u043d\u0434\u044b). \u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440 \u0434\u043e\u043b\u0436\u0435\u043d \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432\u0435, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043d\u0435\u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0433\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u0427\u0442\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0438 \u043f\u043e\u0447\u0435\u043c\u0443 \u043e\u043d\u043e \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u043c?<\/strong><\/p>\n\n\n\n<p>\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u00ab\u0441\u043f\u0438\u043d\u0430 \u043a \u0441\u043f\u0438\u043d\u0435\u00bb \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u043f\u0440\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043d\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438, \u0432 \u0442\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u043a \u0434\u0440\u0443\u0433\u0438\u0435 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u043d\u0430 \u0442\u043e\u0439 \u0436\u0435 \u0448\u0438\u043d\u0435 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c. \u0411\u0430\u0442\u0430\u0440\u0435\u0438 \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0442 \u043a\u0430\u043a \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0441 \u043d\u0438\u0437\u043a\u0438\u043c \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u043e\u043c, \u043e\u0431\u0445\u043e\u0434\u044f \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u0432\u044b\u0437\u044b\u0432\u0430\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0432 100\u2013200 \u0440\u0430\u0437 \u0431\u043e\u043b\u044c\u0448\u0435 \u0432 \u043d\u043e\u0432\u043e\u0439 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u043c\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0435 (\u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 20\u201340 \u0440\u0430\u0437 \u043f\u0440\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043f\u0435\u0440\u0432\u043e\u0439 \u0431\u0430\u0442\u0430\u0440\u0435\u0438). \u042d\u0442\u043e \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u043f\u043e\u0442\u043e\u043c\u0443, \u0447\u0442\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442\u0441\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c\u044e \u043a\u0430\u0431\u0435\u043b\u044f \u2014 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u044b \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u044e\u0442 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0438. \u0421\u043c\u044f\u0433\u0447\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u0439: \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 30-60 \u0441, \u0434\u0435\u0442\u043e\u043d\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u044b 5-7% (\u0443\u043c\u0435\u043d\u044c\u0448\u0430\u044e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043d\u0430 50-70%) \u0438\u043b\u0438 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0438 \u043d\u0443\u043b\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 4: \u041a\u0430\u043a \u0441\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0437\u0430\u0449\u0438\u0442\u0443, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u0438\u0437-\u0437\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430?<\/strong><\/p>\n\n\n\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443 \u043f\u043e \u0442\u043e\u043a\u0443 (\u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 0,5\u20131,0 \u0441), \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u0443\u044e \u0432\u044b\u0448\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430 (5\u201320 \u043c\u0441). \u0414\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u043c: \u0432\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 I\u00b2t &gt;2\u00d7 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 I\u00b2t, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439. \u041f\u0440\u0438\u043c\u0435\u0440: \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440 200 \u0410 \u0441 40\u00d7 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0442\u043e\u043a\u043e\u043c (8 \u043a\u0410 \u043f\u0438\u043a, 10 \u043c\u0441) \u0438\u043c\u0435\u0435\u0442 I\u00b2t = 640 000 \u0410\u00b2\u0441; \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c \u0441 I\u00b2t &gt;1 200 000 \u0410\u00b2\u0441. \u0414\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0440\u0435\u043b\u0435: \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a (\u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 2-\u0439\/3-\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438), \u0435\u0441\u043b\u0438 \u044d\u0442\u043e \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e \u2014 \u0440\u0435\u043b\u0435 \u0441 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u043b\u0438 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 30% \u0432 \u043d\u0430\u0448\u0438\u0445 \u0433\u043e\u0440\u043d\u043e\u0434\u043e\u0431\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0440\u043e\u0441\u0442\u044b\u043c\u0438 \u0440\u0435\u043b\u0435 \u0441 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439. \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 1,3-1,5\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u0447\u0442\u043e\u0431\u044b \u0443\u0447\u0435\u0441\u0442\u044c \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 \u0438 \u0434\u043e\u043f\u0443\u0441\u043a.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 5: \u0412 \u0447\u0435\u043c \u0440\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u0430\u043c\u0438 \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0438 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430\u043c\u0438 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0432\u0441\u0442\u0430\u0432\u043a\u0438?<\/strong><\/p>\n\n\n\n<p>\u0420\u0435\u0430\u043a\u0442\u043e\u0440\u044b \u0440\u0430\u0441\u0441\u0442\u0440\u043e\u0439\u043a\u0438 (\u0438\u043d\u0434\u0443\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0438\u0438 5-7%) \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0432 \u0446\u0435\u043f\u0438 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 \u0432 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u0440\u0435\u0436\u0438\u043c\u0435 \u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a. \u041e\u043d\u0438 \u0441\u043b\u0443\u0436\u0430\u0442 \u0434\u0432\u0443\u043c \u0446\u0435\u043b\u044f\u043c: (1) \u0441\u0434\u0432\u0438\u0433 \u0440\u0435\u0437\u043e\u043d\u0430\u043d\u0441\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u043d\u0438\u0436\u0435 5-\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0443\u0441\u0438\u043b\u0435\u043d\u0438\u044f, (2) \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 50-70% \u0437\u0430 \u0441\u0447\u0435\u0442 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044f \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u0430. \u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e (10-50 \u043c\u0441) \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430, \u0430 \u0437\u0430\u0442\u0435\u043c \u043e\u0431\u0445\u043e\u0434\u044f\u0442\u0441\u044f \u0447\u0435\u0440\u0435\u0437 \u0432\u0442\u043e\u0440\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440. \u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043b\u0443\u0447\u0448\u0438\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (\u043c\u043e\u0433\u0443\u0442 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0442\u044c \u0435\u0433\u043e \u0434\u043e 2-3\u00d7 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 30-50\u00d7 \u0434\u043b\u044f \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u0430), \u043d\u043e \u0434\u043e\u0431\u0430\u0432\u043b\u044f\u044e\u0442 \u0441\u043b\u043e\u0436\u043d\u043e\u0441\u0442\u044c (\u043e\u0431\u0445\u043e\u0434\u043d\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440, \u0440\u0435\u043b\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438). \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435\u043c \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u0438 \u0443\u043c\u0435\u0440\u0435\u043d\u043d\u044b\u043c \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0442\u043e\u043a\u043e\u043c; \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u0434\u043b\u044f \u0442\u044f\u0436\u0435\u043b\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u00ab\u0441\u043f\u0438\u043d\u0430 \u043a \u0441\u043f\u0438\u043d\u0435\u00bb \u0438\u043b\u0438 \u043a\u043e\u0433\u0434\u0430 \u0440\u0430\u0437\u043c\u0435\u0440\/\u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0440\u0435\u0430\u043a\u0442\u043e\u0440\u0430 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0435\u043f\u043e\u043c\u0435\u0440\u043d\u043e \u0432\u044b\u0441\u043e\u043a\u043e\u0439.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 6: \u041a\u0430\u043a \u0447\u0430\u0441\u0442\u043e \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0437\u0430\u043c\u0435\u043d\u044f\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430 \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0441 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430\u043c\u0438?<\/strong><\/p>\n\n\n\n<p>\u0421\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b AC-6b \u043e\u0431\u044b\u0447\u043d\u043e \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 8000\u201315 000 \u0446\u0438\u043a\u043b\u043e\u0432 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0438 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043a\u0430\u0436\u0434\u044b\u0435 2000\u20133000 \u0446\u0438\u043a\u043b\u043e\u0432 (\u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 5000 \u0434\u043b\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439). \u0417\u0430\u043c\u0435\u043d\u044f\u0439\u0442\u0435, \u043a\u043e\u0433\u0434\u0430 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 500 \u043c\u043a\u041e\u043c \u0438\u043b\u0438 \u0432\u0438\u0434\u0438\u043c\u0430\u044f \u044d\u0440\u043e\u0437\u0438\u044f \u0443\u043c\u0435\u043d\u044c\u0448\u0430\u0435\u0442 \u0442\u043e\u043b\u0449\u0438\u043d\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 &gt;30%. \u0412 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 PFC, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u0445\u0441\u044f 6 \u0440\u0430\u0437 \u0432 \u0447\u0430\u0441, \u043e\u0436\u0438\u0434\u0430\u0439\u0442\u0435 \u0437\u0430\u043c\u0435\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043a\u0430\u0436\u0434\u044b\u0435 2-4 \u0433\u043e\u0434\u0430 (8000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u00f7 6 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439\/\u0447\u0430\u0441 \u00f7 8760 \u0447\u0430\u0441\u043e\u0432\/\u0433\u043e\u0434 \u2248 2,5 \u0433\u043e\u0434\u0430). \u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0432\u0441\u0442\u0430\u0432\u043a\u0438 \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u044e\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0434\u043e 20 000+ \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439. \u0412\u0435\u0434\u0438\u0442\u0435 \u0436\u0443\u0440\u043d\u0430\u043b\u044b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f: \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u00b130% \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u0438 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 7: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u044b \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c AC-6b?<\/strong><\/p>\n\n\n\n<p>\u041d\u0435\u0442. \u0414\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 AC-6b \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0434\u0440\u0443\u0433\u043e\u0439 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (CuCr25 \u0432\u043c\u0435\u0441\u0442\u043e CuCr15-20), \u043d\u043e \u0438 \u0431\u043e\u043b\u044c\u0448\u0435\u0435 \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c\u0438 (12-14 \u043c\u043c \u0432\u043c\u0435\u0441\u0442\u043e 8-10 \u043c\u043c), \u0443\u0441\u0438\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0433\u043e \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0438 \u043c\u043e\u0434\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0434\u0443\u0433\u043e\u0432\u044b\u0435 \u043a\u0430\u043c\u0435\u0440\u044b. \u041c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043d\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u2014 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0441\u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u044b \u043a\u0430\u043a \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0434\u043b\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u0430. \u0417\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u0432\u0435\u0441\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043d\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0441 \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u043e\u043c AC-6b. \u041f\u043e\u043f\u044b\u0442\u043a\u0430 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 AC-4 \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u0432\u0430\u0440\u043a\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (\u043d\u0435\u0430\u0434\u0435\u043a\u0432\u0430\u0442\u043d\u044b\u0439 \u0437\u0430\u0437\u043e\u0440) \u0438\u043b\u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044e \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 (\u0443\u0441\u0442\u0430\u043b\u043e\u0441\u0442\u044c \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u043e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0445 \u0441\u0438\u043b). \u041f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438, \u0447\u0442\u043e \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u043e\u0442\u043a\u0430\u0437\u043e\u0432 100% \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 1000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 12 000+ \u0434\u043b\u044f \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 AC-6b.<\/p>","protected":false},"excerpt":{"rendered":"<p>Switching capacitor banks with vacuum contactors creates the most severe transient conditions in medium-voltage motor control applications. Inrush current during energization reaches 20-100\u00d7 rated capacitor current in the first half-cycle, sustained for 5-10 ms before decaying. This transient exceeds the making capacity of standard AC-3 or AC-4 rated contactors, causing contact welding, excessive erosion, and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2398,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-2392","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2392"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2392\/revisions"}],"predecessor-version":[{"id":3568,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2392\/revisions\/3568"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2398"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2392"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2392"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}