{"id":2401,"date":"2026-01-02T08:47:36","date_gmt":"2026-01-02T08:47:36","guid":{"rendered":"https:\/\/xbrele.com\/?p=2401"},"modified":"2026-04-07T14:03:21","modified_gmt":"2026-04-07T14:03:21","slug":"vcb-commissioning-checklist-timing-insulation-interlocks","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/vcb-commissioning-checklist-timing-insulation-interlocks\/","title":{"rendered":"\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0434\u043b\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e (Field-First): \u0441\u0440\u043e\u043a\u0438, \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f, \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438, \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f"},"content":{"rendered":"<p>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0435 \u0432\u044b\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u043f\u0440\u0438\u0435\u043c\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439. \u041e\u043d\u0438 \u043f\u0440\u043e\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043f\u0440\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435, \u043a\u043e\u0433\u0434\u0430 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0434\u0440\u0435\u0431\u0435\u0437\u0436\u0430\u0442 \u0438\u0437-\u0437\u0430 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438, \u043a\u043e\u0433\u0434\u0430 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u0435 \u0437\u0430 90 \u043c\u0441 \u0432\u043c\u0435\u0441\u0442\u043e \u0443\u043a\u0430\u0437\u0430\u043d\u043d\u044b\u0445 60 \u043c\u0441, \u0438\u043b\u0438 \u043a\u043e\u0433\u0434\u0430 \u043f\u0440\u043e\u0431\u0435\u043b\u044b \u0432 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0437\u0430\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u0441\u0434\u0430\u0447\u0443 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u043d\u0430 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043d\u0435\u0434\u0435\u043b\u044c, \u043f\u043e\u043a\u0430 \u043f\u043e\u0434\u0440\u044f\u0434\u0447\u0438\u043a \u0441\u043f\u0435\u0448\u043d\u043e \u0433\u043e\u0442\u043e\u0432\u0438\u0442 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u044e\u0449\u0438\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b. \u042d\u0442\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u044e\u0442 \u0438\u0437-\u0437\u0430<\/p>\n\n\n\n<p>\u043e\u0431\u0449\u0430\u044f \u043f\u0435\u0440\u0432\u043e\u043f\u0440\u0438\u0447\u0438\u043d\u0430: \u043a\u043e\u043c\u0430\u043d\u0434\u044b \u043f\u043e \u0432\u0432\u043e\u0434\u0443 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0441\u043b\u0435\u0434\u0443\u044e\u0442 \u043e\u0431\u0449\u0438\u043c \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0430\u043c \u0432\u043c\u0435\u0441\u0442\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u0445 \u043d\u0430 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0435\u0439 \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0432\u044b\u044f\u0432\u0438\u0442\u044c \u0434\u0435\u0444\u0435\u043a\u0442\u044b \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f, \u043e\u0448\u0438\u0431\u043a\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0438 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u043c \u0434\u043e \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u0412 \u043f\u0435\u0440\u0432\u043e\u043e\u0447\u0435\u0440\u0435\u0434\u043d\u043e\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u043c \u0441\u043f\u0438\u0441\u043a\u0435 \u0434\u043b\u044f \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442 \u043e\u0442\u0434\u0430\u0435\u0442\u0441\u044f \u0442\u0435\u0441\u0442\u0430\u043c, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0438\u043c \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0431\u043e\u0438 \u2014 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u044c \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438, \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0438 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u2014 \u043f\u0435\u0440\u0435\u0434 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043e\u043c \u043a \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439. \u042d\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442\u0441\u044f \u043e\u0442 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u0430\u0433\u0430\u044e\u0442 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b. \u041f\u0440\u0438 \u0432\u0432\u043e\u0434\u0435 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043d\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043d\u0438\u0447\u0435\u0433\u043e \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u0430\u0433\u0430\u0442\u044c: \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0435, \u043e\u0448\u0438\u0431\u043a\u0438 \u043f\u0440\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435 \u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u0440\u0438\u0441\u043a\u0438, \u0441 \u043a\u043e\u0442\u043e\u0440\u044b\u043c\u0438 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0438\u043a\u043e\u0433\u0434\u0430 \u043d\u0435 \u0441\u0442\u0430\u043b\u043a\u0438\u0432\u0430\u044e\u0442\u0441\u044f.<\/p>\n\n\n\n<p>\u0412 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 12 \u043a\u0412, 24 \u043a\u0412 \u0438 40,5 \u043a\u0412, \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u0432 \u0432\u0438\u0434\u0435 \u0434\u0435\u0440\u0435\u0432\u0430 \u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0441 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u044f\u043c\u0438 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f\/\u043d\u0435\u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0430 \u043a\u0430\u0436\u0434\u043e\u043c \u044d\u0442\u0430\u043f\u0435. \u041e\u0441\u043d\u043e\u0432\u043d\u043e\u0435 \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u0443\u0434\u0435\u043b\u044f\u0435\u0442\u0441\u044f \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0430\u0441\u043f\u0435\u043a\u0442\u0430\u043c: \u0447\u0442\u043e \u0438\u0437\u043c\u0435\u0440\u044f\u0442\u044c, \u043a\u0430\u043a\u0438\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0438 \u043a\u043e\u0433\u0434\u0430 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u0440\u0435\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0438 \u044d\u0441\u043a\u0430\u043b\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0434\u043e \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u043f\u0440\u043e\u0438\u0437\u043e\u0439\u0434\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e VCB: \u043f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 12 \u043a\u0412\u201340,5 \u043a\u0412\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/xdqgsw5G0KU?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-field-commissioning-differs-from-factory-testing\">\u041f\u043e\u0447\u0435\u043c\u0443 \u043f\u043e\u043b\u0435\u0432\u043e\u0439 \u0432\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442\u0441\u044f \u043e\u0442 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/h2>\n\n\n\n<p>\u041f\u0440\u0438\u0435\u043c\u043e\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0430\u0432\u043e\u0434\u0435 (FAT) \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0432 \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445: \u0447\u0438\u0441\u0442\u0430\u044f \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0430\u044f \u0441\u0440\u0435\u0434\u0430, \u043e\u0442\u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043f\u0440\u0438\u0431\u043e\u0440\u044b, \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u043f\u043e\u0434 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f. \u0412\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0435\u0442 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445: \u043f\u044b\u043b\u044c, \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u044c, \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f \u0438 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u0442\u0440\u043e\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0440\u0430\u0431\u043e\u0442.<\/p>\n\n\n\n<p>\u0422\u0440\u0438 \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u0432\u044b\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435:<\/p>\n\n\n\n<p><strong>1. \u041f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0435\/\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u0438<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u0440\u0443\u0436\u0438\u043d\u044b \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 \u0442\u0435\u0440\u044f\u044e\u0442 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u0438\u0437-\u0437\u0430 \u0443\u0434\u0430\u0440\u043e\u0432\/\u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438<\/li>\n\n\n\n<li>\u0412 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u044b\u0445 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430\u0445 \u043f\u043e\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043c\u0438\u043a\u0440\u043e\u0442\u0440\u0435\u0449\u0438\u043d\u044b (\u043d\u0435\u0432\u0438\u0434\u0438\u043c\u044b\u0435 \u043f\u0440\u0438 \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u043e\u043c \u043e\u0441\u043c\u043e\u0442\u0440\u0435)<\/li>\n\n\n\n<li>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0440\u0430\u0437\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c \u0441 \u0441\u0438\u043b\u044c\u0444\u043e\u043d\u043e\u043c \u0434\u043e\u043f\u0443\u0441\u043a\u0430\u0435\u0442 \u043c\u0438\u043a\u0440\u043e\u0441\u043a\u043e\u043f\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0443\u0442\u0435\u0447\u043a\u0438 (\u0432\u0430\u043a\u0443\u0443\u043c \u043f\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442\u0441\u044f)<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u041e\u0448\u0438\u0431\u043a\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0431\u0440\u0430\u0442\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f (\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b NO \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u044b \u043a\u0430\u043a NC)<\/li>\n\n\n\n<li>\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043d\u0430\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u0435 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 (\u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043c\u043e\u0436\u0435\u0442 \u0437\u0430\u043c\u043a\u043d\u0443\u0442\u044c\u0441\u044f \u043d\u0430 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u043d\u043e\u0439 \u0448\u0438\u043d\u0435)<\/li>\n\n\n\n<li>\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u043c\u043e\u043c\u0435\u043d\u0442 \u0437\u0430\u0442\u044f\u0436\u043a\u0438 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 (\u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044e \u0433\u043e\u0440\u044f\u0447\u0438\u0445 \u0442\u043e\u0447\u0435\u043a \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439)<\/li>\n<\/ul>\n\n\n\n<p><strong>3. \u041d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c \u0441 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u043e\u0439<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0412\u044b\u0441\u043e\u0442\u0430 \u043d\u0430\u0434 \u0443\u0440\u043e\u0432\u043d\u0435\u043c \u043c\u043e\u0440\u044f &gt;1000 \u043c \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438, \u043d\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u0433\u043e \u0432 \u0445\u043e\u0434\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043f\u0440\u0438\u0435\u043c\u043a\u0435 \u043d\u0430 \u0443\u0440\u043e\u0432\u043d\u0435 \u043c\u043e\u0440\u044f.<\/li>\n\n\n\n<li>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044e \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u0430 \u043d\u0430 \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u043e\u0432 (\u043f\u0443\u0442\u0438 \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c).<\/li>\n\n\n\n<li>\u041d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u0438\u0435 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u0430\u0433\u0430\u0435\u043c\u0443\u044e \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f<\/li>\n<\/ul>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 180 \u0432\u0432\u043e\u0434\u0438\u043c\u044b\u0445 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e 22% VCB \u043f\u0440\u043e\u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u043e\u0432\u0430\u043b\u0438 \u043f\u043e\u043b\u0435\u0432\u044b\u0435 \u0434\u0435\u0444\u0435\u043a\u0442\u044b, \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0432 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445, \u2014 \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c \u0434\u0440\u0435\u0439\u0444 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 (\u00b115%), \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0438\u0437-\u0437\u0430 \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u0438 \u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0438\u0437-\u0437\u0430 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/what-is-vacuum-circuit-breaker-working-principle\/\">\u041f\u0440\u0438\u043d\u0446\u0438\u043f\u044b \u0440\u0430\u0431\u043e\u0442\u044b VCB<\/a>&nbsp;\u0438&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-ratings\/\">\u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/a>&nbsp;\u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u0443\u044e \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044e \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u0447\u0430\u043b\u043e\u043c \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01.webp\" alt=\"\u0418\u043d\u0444\u043e\u0433\u0440\u0430\u0444\u0438\u043a\u0430, \u0441\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u044e\u0449\u0430\u044f \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0435 \u043f\u0440\u0438\u0435\u043c\u043e\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0438 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438.\" class=\"wp-image-2403\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 1. \u0417\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0432 \u0438\u0434\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445; \u0432 \u0445\u043e\u0434\u0435 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f, \u0432\u043e\u0437\u043d\u0438\u043a\u0448\u0438\u0435 \u043f\u0440\u0438 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0435, \u043e\u0448\u0438\u0431\u043a\u0438 \u043c\u043e\u043d\u0442\u0430\u0436\u0430 \u0438 \u043d\u0435\u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c \u0441 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u043e\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u043e\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u0440\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-1-pre-energization-safety-checks-30-minutes\">\u042d\u0442\u0430\u043f 1: \u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0435\u0434 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u043f\u0438\u0442\u0430\u043d\u0438\u044f (30 \u043c\u0438\u043d\u0443\u0442)<\/h2>\n\n\n\n<p>\u0412\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u0435 \u044d\u0442\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e&nbsp;<strong>\u0432\u0441\u0435 \u0446\u0435\u043f\u0438 \u043e\u0431\u0435\u0441\u0442\u043e\u0447\u0435\u043d\u044b \u0438 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u044b<\/strong>. \u041d\u0435\u0443\u0434\u0430\u0447\u0430 \u043d\u0430 \u044d\u0442\u043e\u043c \u044d\u0442\u0430\u043f\u0435 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043e\u0442 \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>1.1 \u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00a0\u0421\u043d\u044f\u0442\u044b \u043a\u0440\u0435\u043f\u0435\u0436\u043d\u044b\u0435 \u0441\u043a\u043e\u0431\u044b (\u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c, \u043a\u0440\u0435\u043f\u043b\u0435\u043d\u0438\u0435 VI)<\/li>\n\n\n\n<li>\u00a0\u0418\u043d\u043e\u0440\u043e\u0434\u043d\u044b\u0435 \u043f\u0440\u0435\u0434\u043c\u0435\u0442\u044b \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0432 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u043c \u043e\u0442\u0441\u0435\u043a\u0435<\/li>\n\n\n\n<li>\u00a0\u042d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u044b\u0435 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u044b \u0431\u0435\u0437 \u0442\u0440\u0435\u0449\u0438\u043d, \u0441\u043a\u043e\u043b\u043e\u0432, \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0439<\/li>\n\n\n\n<li>\u00a0\u041f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0435 \u0432\u0442\u0443\u043b\u043a\u0438 \u0437\u0430\u0442\u044f\u043d\u0443\u0442\u044b \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043e\u043c (\u043e\u0431\u044b\u0447\u043d\u043e 40-60 \u041d\u22c5\u043c \u0434\u043b\u044f \u0448\u043f\u0438\u043b\u0435\u043a M12)<\/li>\n\n\n\n<li>\u00a0\u0417\u0430\u0437\u0435\u043c\u043b\u044f\u044e\u0449\u0438\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e \u0437\u0430\u043a\u0440\u0435\u043f\u043b\u0435\u043d\u044b (\u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435: &lt;0,1 \u041e\u043c)<\/li>\n<\/ul>\n\n\n\n<p><strong>1.2 \u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00a0\u0420\u0443\u0447\u043d\u043e\u0435 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435 \u0437\u0430\u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u043e \u043f\u0440\u0438 \u0437\u0430\u043c\u043a\u043d\u0443\u0442\u043e\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u044f\u044e\u0449\u0435\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435<\/li>\n\n\n\n<li>\u00a0\u041d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e \u0438\u0437\u0432\u043b\u0435\u0447\u044c \u0441\u044a\u0435\u043c\u043d\u044b\u0439 \u044d\u043b\u0435\u043c\u0435\u043d\u0442 \u043f\u0440\u0438 \u0437\u0430\u043c\u043a\u043d\u0443\u0442\u043e\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435<\/li>\n\n\n\n<li>\u00a0\u0411\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0434\u0432\u0435\u0440\u0435\u0439 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u0442\u043e\u043a\u043e\u0432\u0435\u0434\u0443\u0449\u0438\u043c \u0447\u0430\u0441\u0442\u044f\u043c<\/li>\n\n\n\n<li>\u00a0\u0424\u0443\u043d\u043a\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043a\u0430\u0447\u043a\u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u044b\u0435 \u043a\u043e\u043c\u0430\u043d\u0434\u044b \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0442\u0435\u0441\u0442<\/strong>: \u041f\u043e\u043f\u044b\u0442\u043a\u0430 \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u0437\u0430\u043f\u0440\u0435\u0449\u0435\u043d\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0435 \u0441 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435\u043c, \u0438\u0437\u0432\u043b\u0435\u0447\u0435\u043d\u0438\u0435 \u0432 \u0437\u0430\u043a\u0440\u044b\u0442\u043e\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438). \u0411\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0434\u043e\u043b\u0436\u043d\u0430 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u2014 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 IEC 62271-200 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u043c\u0438.<\/p>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f<\/strong>: \u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b \u043d\u0443\u043b\u0435\u0432\u044b\u0435 \u0437\u0430\u043f\u0440\u0435\u0449\u0435\u043d\u043d\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438.<br><strong>\u0414\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043f\u0440\u0438 \u0441\u0431\u043e\u0435<\/strong>: \u041e\u0442\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u043a\u0443\u043b\u0430\u0447\u043a\u0438\/\u0440\u044b\u0447\u0430\u0433\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438. \u041d\u0435 \u0432\u043a\u043b\u044e\u0447\u0430\u0439\u0442\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u0435 \u0434\u043e \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f 100%.<\/p>\n\n\n\n<p><strong>1.3 \u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 (\u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435: 2,5 \u043a\u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (\u0434\u043b\u044f 12 \u043a\u0412 VCB), 5 \u043a\u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (\u0434\u043b\u044f 24 \u043a\u0412)<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0444\u0430\u0437\u0430-\u0437\u0435\u043c\u043b\u044f, \u0444\u0430\u0437\u0430-\u0444\u0430\u0437\u0430 (\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u044e\u0442\u0441\u044f)<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>: &gt;1000 \u041c\u041e\u043c (&gt;2000 \u041c\u041e\u043c \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e)<\/li>\n\n\n\n<li><strong>\u041c\u0430\u0440\u0433\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439<\/strong>\u00a0(100\u20131000 \u041c\u041e\u043c): \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0439, \u0432\u043b\u0430\u0433\u0438<\/li>\n\n\n\n<li><strong>\u041d\u0435\u0443\u0434\u0430\u0447\u0430<\/strong>\u00a0(&lt;100 \u041c\u041e\u043c): \u041e\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435\u0441\u044c. \u0412\u044b\u0441\u0443\u0448\u0438\u0442\u0435 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b.<\/li>\n<\/ul>\n\n\n\n<p>\u041f\u043e \u043d\u0430\u0448\u0435\u043c\u0443 \u043e\u043f\u044b\u0442\u0443, 8% VCB \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 2000 \u041c\u041e\u043c.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-2-contact-timing-tests-1-2-hours\">\u042d\u0442\u0430\u043f 2: \u0422\u0435\u0441\u0442\u044b \u043d\u0430 \u0432\u0440\u0435\u043c\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 (1\u20132 \u0447\u0430\u0441\u0430)<\/h2>\n\n\n\n<p>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u043e\u043b\u0436\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u044c\u0441\u044f \u0434\u043e \u043f\u043e\u0434\u0430\u0447\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u2014 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044e \u0434\u0443\u0433\u043e\u0439, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0443\u0441\u0443\u0433\u0443\u0431\u043b\u044f\u0435\u0442\u0441\u044f \u0441 \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0435\u0439.<\/p>\n\n\n\n<p><strong>2.1 \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0439<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0430\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440 VCB (OMICRON CPC 100, Megger TM1800 \u0438\u043b\u0438 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u0439).<\/li>\n\n\n\n<li>\u041f\u043e\u0434\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043a \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u043c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f.<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u0434\u0430\u0442\u0447\u0438\u043a\u0430 \u0445\u043e\u0434\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 (\u0435\u0441\u043b\u0438 \u0438\u0437\u043c\u0435\u0440\u044f\u0435\u0442\u0441\u044f \u0445\u043e\u0434)<\/li>\n<\/ul>\n\n\n\n<p><strong>2.2 \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0437\u0430\u0440\u044f\u0434\u043a\u0438 (\u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0439, \u0441\u043e\u043b\u0435\u043d\u043e\u0438\u0434\u043d\u044b\u0439 \u0438\u043b\u0438 \u0433\u0438\u0434\u0440\u0430\u0432\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0442\u0438\u043f\u0430)<\/li>\n\n\n\n<li>\u0412\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043a\u043e\u043c\u0430\u043d\u0434\u0443 \u00ab\u041f\u043e\u0435\u0437\u0434\u043a\u0430\u00bb<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0432\u0440\u0435\u043c\u044f \u043e\u0442 \u0441\u0438\u0433\u043d\u0430\u043b\u0430 \u043f\u043e\u0435\u0437\u0434\u043a\u0438 \u0434\u043e \u043f\u043e\u043b\u043d\u043e\u0433\u043e \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 (12 \u043a\u0412 VCB, \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c)<\/strong>:<br>\u2022\u00a0<strong>\u0412\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b<\/strong>: 30\u201360 \u043c\u0441 (\u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-100, \u043f\u0443\u043d\u043a\u0442 6.111)<br>\u2022 \u0414\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u0439 \u0434\u043e\u043f\u0443\u0441\u043a: \u00b110% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f<br>\u2022 \u0422\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0439 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u043c: \u0440\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 \u0441\u0430\u043c\u044b\u043c \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u044b\u043c \u0438 \u0441\u0430\u043c\u044b\u043c \u0431\u044b\u0441\u0442\u0440\u044b\u043c \u043f\u043e\u043b\u044e\u0441\u043e\u043c \u22643 \u043c\u0441<\/p>\n\n\n\n<p><strong>2.3 \u0422\u0435\u0441\u0442 \u043d\u0430 \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041a\u043e\u043c\u0430\u043d\u0434\u0430 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0432\u0440\u0435\u043c\u044f \u043e\u0442 \u0441\u0438\u0433\u043d\u0430\u043b\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043e \u043f\u043e\u043b\u043d\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432.<\/li>\n\n\n\n<li><strong>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0439<\/strong>: 60\u2013100 \u043c\u0441 \u0434\u043b\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u0432<\/li>\n<\/ul>\n\n\n\n<p><strong>2.4 \u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043e\u0442\u0441\u043a\u043e\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0437\u043c\u0435\u0440\u044f\u0442\u044c \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0437\u0430\u043a\u0440\u044b\u0442\u043e\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438<\/li>\n\n\n\n<li>\u0414\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u0442\u0441\u043a\u043e\u043a\u0430 \u0434\u043e\u043b\u0436\u043d\u0430 \u0431\u044b\u0442\u044c &lt;2 \u043c\u0441.<\/li>\n\n\n\n<li>\u041c\u043d\u043e\u0433\u043e\u043a\u0440\u0430\u0442\u043d\u044b\u0435 \u043e\u0442\u0441\u043a\u043e\u043a\u0438 (&gt;3) \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0441 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u043c<\/li>\n<\/ul>\n\n\n\n<p>\u041c\u044b \u0438\u0437\u043c\u0435\u0440\u0438\u043b\u0438 12% \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 VCB, \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0445 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u044f \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043d\u044b\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u2014 \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c \u0438\u0437-\u0437\u0430 \u043f\u043e\u0442\u0435\u0440\u0438 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438\u043b\u0438 \u0438\u0437\u043d\u043e\u0441\u0430 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0438. \u0420\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0430 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u043b\u0430 90% \u0434\u043e \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438; 10% \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043b \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u043e\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02.webp\" alt=\"\u041e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u043c\u043c\u0430, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0441 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0441\u0438\u0433\u043d\u0430\u043b\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043e\u043c \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\" class=\"wp-image-2405\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 2. \u041e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u043c\u043c\u0430 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f 50 \u043c\u0441 (\u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 IEC 62271-100 \u043e\u0442 30 \u0434\u043e 60 \u043c\u0441 \u0434\u043b\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 12 \u043a\u0412) \u0441 \u0437\u0430\u0436\u0438\u0433\u0430\u043d\u0438\u0435\u043c \u0434\u0443\u0433\u0438 \u0447\u0435\u0440\u0435\u0437 15 \u043c\u0441 \u0438 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043e\u043c \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0447\u0435\u0440\u0435\u0437 48 \u043c\u0441.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-3-high-voltage-testing-2-3-hours\">\u042d\u0442\u0430\u043f 3: \u0412\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 (2\u20133 \u0447\u0430\u0441\u0430)<\/h2>\n\n\n\n<p>\u0412\u044b\u043f\u043e\u043b\u043d\u044f\u0439\u0442\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u2014 \u043d\u0435 \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u0430\u0439\u0442\u0435 \u0442\u0435\u0441\u0442\u044b. \u041a\u0430\u0436\u0434\u044b\u0439 \u0438\u0437 \u043d\u0438\u0445 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0435\u0442 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u0440\u0435\u0436\u0438\u043c\u044b \u043e\u0442\u043a\u0430\u0437\u0430.<\/p>\n\n\n\n<p><strong>3.1 \u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0438\u0442\u0430\u043d\u0438\u044f (PFWT)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435: 28 \u043a\u0412 RMS \u0434\u043b\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f 12 \u043a\u0412 (\u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-100, \u0442\u0430\u0431\u043b\u0438\u0446\u0430 1)<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c: \u043c\u0438\u043d\u0438\u043c\u0443\u043c 1 \u043c\u0438\u043d\u0443\u0442\u0430<\/li>\n\n\n\n<li>\u041f\u0440\u0438\u043b\u043e\u0436\u0438\u0442\u0435 \u0444\u0430\u0437\u0443 \u043a \u0437\u0435\u043c\u043b\u0435 (\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u044b), \u0444\u0430\u0437\u0443 \u043a \u0444\u0430\u0437\u0435 \u0447\u0435\u0440\u0435\u0437 \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b.<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>: \u0411\u0435\u0437 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f, \u0431\u0435\u0437 \u0442\u0440\u0435\u043a\u0438\u043d\u0433\u0430, \u0431\u0435\u0437 \u0447\u0430\u0441\u0442\u0438\u0447\u043d\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432 &gt;10 \u043f\u041a<\/li>\n<\/ul>\n\n\n\n<p><strong>3.2 \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0438\u043c \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u043c<\/strong>&nbsp;(\u0435\u0441\u043b\u0438 \u0443\u043a\u0430\u0437\u0430\u043d\u043e)<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>75 \u043a\u0412 \u043f\u0438\u043a \u0434\u043b\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f 12 \u043a\u0412<\/li>\n\n\n\n<li>15 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 + 15 \u043e\u0442\u0440\u0438\u0446\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>: \u0411\u0435\u0437 \u0432\u043e\u0437\u0433\u043e\u0440\u0430\u043d\u0438\u044f<\/li>\n<\/ul>\n\n\n\n<p><strong>3.3 \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043c\u0438\u043a\u0440\u043e\u043e\u043c\u043c\u0435\u0442\u0440\u0430 (100 \u0410 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438\u043b\u0438 \u0431\u043e\u043b\u0435\u0435).<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>\u00a0(12 \u043a\u0412, \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c 630 \u0410): &lt;150 \u043c\u043a\u041e\u043c \u043d\u0430 \u043f\u043e\u043b\u044e\u0441<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>\u00a0(24 \u043a\u0412, \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c 1250 \u0410): &lt;80 \u043c\u043a\u041e\u043c \u043d\u0430 \u043f\u043e\u043b\u044e\u0441<\/li>\n\n\n\n<li>\u0420\u0430\u0437\u043d\u043e\u0441\u0442\u044c \u043c\u0435\u0436\u0434\u0443 \u043f\u043e\u043b\u044e\u0441\u0430\u043c\u0438: &lt;20%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0442\u043e\u043a\u0443 \u043c\u0438\u043a\u0440\u043e\u043e\u043c\u043c\u0435\u0442\u0440\u0430<\/strong>:<br>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u2265100 \u0410 \u0434\u043b\u044f \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044f \u0438\u0437\u043c\u0435\u0440\u0438\u043c\u043e\u0433\u043e \u043f\u0430\u0434\u0435\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u0445 \u0441 \u043d\u0438\u0437\u043a\u0438\u043c \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435\u043c. \u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u0442\u043e\u043a\u0438 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043c\u0410 \u043c\u0443\u043b\u044c\u0442\u0438\u043c\u0435\u0442\u0440\u0430) \u0434\u0430\u044e\u0442 \u043b\u043e\u0436\u043d\u044b\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u043e\u043a\u0441\u0438\u0434\u043d\u044b\u0445 \u043f\u043b\u0435\u043d\u043e\u043a, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u043e\u0431\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0442\u043e\u043a\u043e\u043c 100 \u0410.<\/p>\n\n\n\n<p>\u041f\u043e\u043b\u043d\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043f\u0440\u0438\u0435\u043c\u043a\u0438 \u0441\u043c. \u0432&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/iec-62271-100-type-test-vs-routine-test-vcb-rfq\/\">\u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEC 62271-100 \u0438 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0440\u0443\u0442\u0438\u043d\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/a>&nbsp;\u0438 \u044d\u0442\u043e&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vcb-maintenance-checklist\/\">\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f VCB<\/a>. \u041e\u0444\u0438\u0446\u0438\u0430\u043b\u044c\u043d\u0430\u044f \u0437\u0430\u043f\u0438\u0441\u044c \u043e \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438 \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u0430 \u043f\u043e \u0430\u0434\u0440\u0435\u0441\u0443&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6734\" target=\"_blank\" rel=\"noopener\">\u041c\u042d\u041a 62271-100<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-4-control-circuit-functional-tests-1-hour\">\u042d\u0442\u0430\u043f 4: \u0424\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f (1 \u0447\u0430\u0441)<\/h2>\n\n\n\n<p><strong>4.1 \u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u044c\u0442\u0435 \u0432\u0441\u0435 NO\/NC \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0441\u0445\u0435\u043c\u043e\u0439<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f<\/li>\n\n\n\n<li>\u041d\u0430\u0433\u0440\u0443\u0437\u0438\u0442\u0435 \u043a\u0430\u0436\u0434\u044b\u0439 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0442\u043e\u043a\u043e\u043c (\u043e\u0431\u044b\u0447\u043d\u043e 5-10 \u0410).<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>: \u0412\u0441\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0430\u0434\u0435\u0436\u043d\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439<\/li>\n<\/ul>\n\n\n\n<p><strong>4.2 \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430\u043a\u0430\u0447\u043a\u0435<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0423\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0439\u0442\u0435 \u043a\u043d\u043e\u043f\u043a\u0443 \u00abHold close\u00bb (\u0423\u0434\u0435\u0440\u0436\u0430\u0442\u044c \u0431\u043b\u0438\u0437\u043a\u043e) \u043f\u0440\u0438 \u0432\u044b\u0434\u0430\u0447\u0435 \u043a\u043e\u043c\u0430\u043d\u0434\u044b \u043d\u0430 \u043f\u043e\u0435\u0437\u0434\u043a\u0443.<\/li>\n\n\n\n<li>\u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0434\u043e\u043b\u0436\u0435\u043d \u0441\u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0438 \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438 (\u043d\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0438 \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043a\u043d\u043e\u043f\u043a\u0438)<\/li>\n\n\n\n<li><strong>\u041d\u0435\u0443\u0434\u0430\u0447\u0430<\/strong>: \u041d\u0430\u0441\u043e\u0441\u044b \u0441 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0435\u043c (\u043f\u043e\u0432\u0442\u043e\u0440\u044f\u044e\u0449\u0438\u0435\u0441\u044f \u0446\u0438\u043a\u043b\u044b \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f-\u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f) \u2014 \u043e\u0442\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u0440\u0435\u043b\u0435 \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u043d\u0430\u0441\u043e\u0441\u0430<\/li>\n<\/ul>\n\n\n\n<p><strong>4.3 \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0423\u043c\u0435\u043d\u044c\u0448\u0438\u0442\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0434\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f 70% (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, 77 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0434\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b 110 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430).<\/li>\n\n\n\n<li>\u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0434\u043e\u043b\u0436\u0435\u043d \u0441\u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u0438\u043b\u0438 \u043e\u0442\u043a\u0430\u0437\u0430\u0442\u044c\u0441\u044f \u043e\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>: \u0420\u0430\u0431\u043e\u0442\u0430 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u0438\u043b\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u0442 \u043f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 70-80%.<\/li>\n<\/ul>\n\n\n\n<p><strong>4.4 \u0418\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u044f \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438\u043d\u0434\u0438\u043a\u0430\u0442\u043e\u0440 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c.<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043f\u043e\u043b\u043d\u044b\u0439 \u0446\u0438\u043a\u043b: \u043e\u0442\u043a\u0440\u044b\u0442\u043e \u2192 \u0437\u0430\u043a\u0440\u044b\u0442\u043e \u2192 \u043e\u0442\u043a\u0440\u044b\u0442\u043e<\/li>\n\n\n\n<li>\u041d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0440\u0440\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u043a\u0438<\/li>\n<\/ul>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 95 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u0432\u044b\u044f\u0432\u0438\u043b\u043e 15% \u043e\u0448\u0438\u0431\u043e\u043a \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f NO\/NC \u0432 \u0446\u0435\u043f\u044f\u0445 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u2014 \u043a\u0430\u043a \u043f\u0440\u0430\u0432\u0438\u043b\u043e, \u044d\u0442\u043e \u0431\u044b\u043b\u0438 \u043e\u0448\u0438\u0431\u043a\u0438 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u0438\u043a\u043e\u0432, \u0430 \u043d\u0435 \u0434\u0435\u0444\u0435\u043a\u0442\u044b \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f. \u0424\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u044b\u044f\u0432\u043b\u044f\u0435\u0442 \u0442\u0430\u043a\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 \u0434\u043e \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u0433\u0434\u0430 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0441\u0431\u043e\u044f\u043c \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 \u0437\u0430\u0449\u0438\u0442\u044b.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"572\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03.webp\" alt=\"\u0411\u043b\u043e\u043a-\u0441\u0445\u0435\u043c\u0430, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0446\u0435\u043f\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u043c \u0441 \u0442\u0435\u0441\u0442\u043e\u043c \u043d\u0430 \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430\u043a\u0430\u0447\u043a\u0435 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u043e\u0439 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u0438 \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438\" class=\"wp-image-2406\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03.webp 572w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03-168x300.webp 168w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03-7x12.webp 7w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 3. \u0411\u043b\u043e\u043a-\u0441\u0445\u0435\u043c\u0430 \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0441 \u0442\u043e\u0447\u043a\u0430\u043c\u0438 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u044f \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u043e \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u0438\/\u043d\u0435\u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u0438 \u0442\u0435\u0441\u0442\u0430 \u0434\u043b\u044f \u0441\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0430\u043d\u0442\u0438\u043f\u043e\u043c\u043f\u0430, \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u043e \u043d\u0438\u0437\u043a\u043e\u043c\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0438\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u0438 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-5-documentation-validation-30-minutes\">\u042d\u0442\u0430\u043f 5: \u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 (30 \u043c\u0438\u043d\u0443\u0442)<\/h2>\n\n\n\n<p>\u041d\u0435 \u043f\u0440\u0438\u043d\u0438\u043c\u0430\u0439\u0442\u0435 \u043d\u0435\u043f\u043e\u043b\u043d\u0443\u044e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044e \u2014 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0437\u0430\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435 \u0438 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u0441\u043f\u043e\u0440\u044b \u043f\u043e \u043f\u043e\u0432\u043e\u0434\u0443 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0438.<\/p>\n\n\n\n<p><strong>\u041d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u044b\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u044b (\u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043d\u0430\u0431\u043e\u0440):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00a0\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 IEC 62271-100 (\u043e\u0442 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438: KEMA, CESI, CPRI)<\/li>\n\n\n\n<li>\u00a0\u041e\u0442\u0447\u0435\u0442 \u043e \u043f\u043b\u0430\u043d\u043e\u0432\u043e\u043c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0438 (\u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0439 \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0439 \u043d\u043e\u043c\u0435\u0440)<\/li>\n\n\n\n<li>\u00a0\u0427\u0435\u0440\u0442\u0435\u0436\u0438 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432 (\u0436\u0435\u043b\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0432 \u0444\u043e\u0440\u043c\u0430\u0442\u0435 CAD)<\/li>\n\n\n\n<li>\u00a0\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 (\u043d\u0430 \u044f\u0437\u044b\u043a\u0435, \u043f\u043e\u043d\u044f\u0442\u043d\u043e\u043c \u0434\u043b\u044f \u043a\u043e\u043c\u0430\u043d\u0434\u044b \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e)<\/li>\n\n\n\n<li>\u00a0\u0421\u043f\u0438\u0441\u043e\u043a \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0441 \u043d\u043e\u043c\u0435\u0440\u0430\u043c\u0438 \u0434\u0435\u0442\u0430\u043b\u0435\u0439 \u0438 \u0441\u0440\u043e\u043a\u0430\u043c\u0438 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0438<\/li>\n\n\n\n<li>\u00a0\u0413\u0440\u0430\u0444\u0438\u043a \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0441 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u0430\u043c\u0438<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430<\/strong>: \u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0434\u043e\u043b\u0436\u0435\u043d \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u043a\u043b\u0430\u0441\u0441\u0443 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f. \u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u043d\u0430 \u201c12 \u043a\u0412, 630 \u0410, 25 \u043a\u0410\u201d \u043d\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0435\u0442 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u201c12 \u043a\u0412, 630 \u0410, 31,5 \u043a\u0410\u201d \u2014 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u043f\u043e \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c\u0443 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439.<\/p>\n\n\n\n<p><strong>\u041e\u0442\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0445 \u043d\u043e\u043c\u0435\u0440\u043e\u0432<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043b\u0438 \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0439 \u043d\u043e\u043c\u0435\u0440 \u043d\u0430 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u043e\u0439 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0435 \u043e\u0442\u0447\u0435\u0442\u0443 \u043e \u043f\u043b\u0430\u043d\u043e\u0432\u043e\u043c \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438.<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0434\u0430\u0442\u0443 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f (\u0438\u0437\u0431\u0435\u0433\u0430\u0439\u0442\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432, \u0441\u0440\u043e\u043a \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 2 \u0433\u043e\u0434\u0430 \u2014 \u0432\u0430\u043a\u0443\u0443\u043c \u043c\u043e\u0436\u0435\u0442 \u0443\u0445\u0443\u0434\u0448\u0438\u0442\u044c\u0441\u044f).<\/li>\n\n\n\n<li>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u0435, \u0447\u0442\u043e \u0434\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u043d\u043e\u0439 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0437\u0430\u043a\u0430\u0437\u0430 \u043d\u0430 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0443.<\/li>\n<\/ul>\n\n\n\n<p>\u041c\u044b \u043e\u0442\u043a\u043b\u043e\u043d\u0438\u043b\u0438 12% \u043f\u043e\u0441\u0442\u0430\u0432\u043e\u043a VCB \u0438\u0437-\u0437\u0430 \u043d\u0435\u043f\u043e\u043b\u043d\u043e\u0442\u044b \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u2014 \u0432 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u043b\u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438\u043b\u0438 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u043f\u043b\u0430\u043d\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0434\u043b\u044f \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0445 \u043d\u043e\u043c\u0435\u0440\u043e\u0432. \u0418\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u043e\u043c \u0437\u0430\u043d\u044f\u043b\u043e 3\u20138 \u043d\u0435\u0434\u0435\u043b\u044c, \u0447\u0442\u043e \u0437\u0430\u0434\u0435\u0440\u0436\u0430\u043b\u043e \u0432\u0432\u043e\u0434 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-6-load-testing-and-monitoring-first-30-days\">\u042d\u0442\u0430\u043f 6: \u041d\u0430\u0433\u0440\u0443\u0437\u043e\u0447\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 (\u043f\u0435\u0440\u0432\u044b\u0435 30 \u0434\u043d\u0435\u0439)<\/h2>\n\n\n\n<p><strong>6.1 \u041f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u043d\u0430\u0447\u0430\u043b\u0430 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u0435 \u0431\u0435\u0437 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (\u0431\u0435\u0437 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0438\u0436\u0435\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f).<\/li>\n\n\n\n<li>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 2 \u0447\u0430\u0441\u043e\u0432: \u043d\u0435\u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0448\u0443\u043c, \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432, \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0447\u0435\u0440\u0435\u0437 24 \u0447\u0430\u0441\u0430 (\u043e\u043d\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f &gt;1000 \u041c\u041e\u043c).<\/li>\n<\/ul>\n\n\n\n<p><strong>6.2 \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0441 \u043c\u0430\u043b\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0439\u0442\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u0434\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 25%, 50%, 75%, 100%.<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043d\u0430 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f\u0445 (\u0436\u0435\u043b\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0418\u041a-\u043a\u0430\u043c\u0435\u0440\u044b).<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u043f\u0443\u0441\u043a<\/strong>: \u0394T &lt;50 K \u0432\u044b\u0448\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435<\/li>\n<\/ul>\n\n\n\n<p><strong>6.3 \u041c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u043f\u0435\u0440\u0432\u044b\u0445 10 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0417\u0430\u043f\u0438\u0448\u0438\u0442\u0435 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u0434\u043b\u044f \u043f\u0435\u0440\u0432\u044b\u0445 10 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/li>\n\n\n\n<li>\u0412\u0440\u0435\u043c\u044f \u0434\u043e\u043b\u0436\u043d\u043e \u0441\u0442\u0430\u0431\u0438\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u00b15 \u043c\u0441 \u043f\u043e\u0441\u043b\u0435 3-5 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/li>\n\n\n\n<li>\u0422\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u044f \u043a \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0443 \u0441 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u043c<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041f\u0440\u0435\u0434\u0435\u043b\u044b \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-100<\/strong>:<br>\u2022 \u041c\u0435\u0434\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b: &lt;75 K \u0432\u044b\u0448\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<br>\u2022 \u041f\u043e\u0441\u0435\u0440\u0435\u0431\u0440\u0435\u043d\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b: &lt;80 K<br>\u2022 \u0411\u043e\u043b\u0442\u043e\u0432\u044b\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0448\u0438\u043d: &lt;105 K<br>\u041f\u0440\u0435\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043f\u043b\u043e\u0445\u043e\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u043b\u0438 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043a\u0440\u0443\u0442\u044f\u0449\u0438\u0439 \u043c\u043e\u043c\u0435\u043d\u0442.<\/p>\n\n\n\n<p>\u0412 \u0445\u043e\u0434\u0435 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u044f \u0431\u043e\u043b\u0435\u0435 200 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043f\u0435\u0440\u0432\u044b\u0445 30 \u0434\u043d\u0435\u0439 \u0431\u044b\u043b\u043e \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u043e 95% \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u043f\u0440\u0438 \u0432\u0432\u043e\u0434\u0435 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e. \u0418\u0445 \u0441\u0432\u043e\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0435 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043f\u0440\u043e\u0431\u043b\u0435\u043c, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0445 \u0441 \u0438\u0441\u0442\u0435\u0447\u0435\u043d\u0438\u0435\u043c \u0441\u0440\u043e\u043a\u0430 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04.webp\" alt=\"\u0413\u0440\u0430\u0444\u0438\u043a, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u043f\u0435\u0440\u0432\u044b\u0435 30 \u0434\u043d\u0435\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0441 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438 \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439 \u0438 \u044d\u0442\u0430\u043f\u0430\u043c\u0438 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u044f \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432.\" class=\"wp-image-2402\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 4. \u041f\u0435\u0440\u0432\u044b\u0439 30-\u0434\u043d\u0435\u0432\u043d\u044b\u0439 \u0433\u0440\u0430\u0444\u0438\u043a \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0444\u0438\u043a\u0441\u0438\u0440\u0443\u0435\u0442 95% \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e\u043c \u043f\u043e\u044d\u0442\u0430\u043f\u043d\u043e\u0433\u043e \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f: \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f (\u0434\u0435\u043d\u044c 1), \u0440\u0430\u0431\u043e\u0442\u0430 \u0441 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439 (\u0434\u0435\u043d\u044c 7), \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b (\u0434\u0435\u043d\u044c 14) \u0438 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 (\u0434\u0435\u043d\u044c 30).<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-commissioning-failures-and-root-causes\">\u0420\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0435 \u0441\u0431\u043e\u0438 \u043f\u0440\u0438 \u0432\u0432\u043e\u0434\u0435 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0438 \u0438\u0445 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0440\u0438\u0447\u0438\u043d\u044b<\/h2>\n\n\n\n<p><strong>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c: \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044e \u043d\u0430 &gt;15%<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u043f\u0440\u0438\u0447\u0438\u043d\u0430: \u043f\u043e\u0442\u0435\u0440\u044f \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438\u0437-\u0437\u0430 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438 \u043f\u0440\u0438 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0435.<\/li>\n\n\n\n<li>\u0418\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435: \u043f\u0435\u0440\u0435\u043d\u0430\u0442\u044f\u043d\u0438\u0442\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u043e\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f (\u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0439 \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u044c).<\/li>\n\n\n\n<li>\u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435: \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0430 \u0441 \u0437\u0430\u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c\/\u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u043c<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c: \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 &lt;100 \u041c\u041e\u043c<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u043f\u0440\u0438\u0447\u0438\u043d\u0430: \u043f\u043e\u0433\u043b\u043e\u0449\u0435\u043d\u0438\u0435 \u0432\u043b\u0430\u0433\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f\/\u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0438<\/li>\n\n\n\n<li>\u0418\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435: \u043d\u0430\u0433\u0440\u0435\u0439\u0442\u0435 \u043e\u0442\u0441\u0435\u043a \u0434\u043e 40 \u00b0C \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 8\u201312 \u0447\u0430\u0441\u043e\u0432, \u043f\u043e\u0432\u0442\u043e\u0440\u0438\u0442\u0435 \u0442\u0435\u0441\u0442.<\/li>\n\n\n\n<li>\u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435: \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435, \u0447\u0442\u043e \u0440\u0435\u0439\u0442\u0438\u043d\u0433 IP \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u043c \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c: \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0434\u0440\u0435\u0431\u0435\u0437\u0436\u0430\u0442 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u043f\u0440\u0438\u0447\u0438\u043d\u0430: \u043e\u0441\u043b\u0430\u0431\u043b\u0435\u043d\u043d\u044b\u0435 \u043a\u0440\u0435\u043f\u0435\u0436\u043d\u044b\u0435 \u0432\u0438\u043d\u0442\u044b \u0438\u043b\u0438 \u0438\u0437\u043d\u043e\u0448\u0435\u043d\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b.<\/li>\n\n\n\n<li>\u0418\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435: \u0437\u0430\u0442\u044f\u043d\u0443\u0442\u044c \u043a\u0440\u0435\u043f\u043b\u0435\u043d\u0438\u0435, \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u0438\u0437\u043d\u043e\u0448\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b<\/li>\n\n\n\n<li>\u041f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435: \u0432\u0438\u0431\u0440\u043e\u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0435 \u043a\u0440\u0435\u043f\u0435\u0436\u043d\u044b\u0435 \u0434\u0435\u0442\u0430\u043b\u0438 (Loctite, \u0441\u0442\u043e\u043f\u043e\u0440\u043d\u044b\u0435 \u0448\u0430\u0439\u0431\u044b)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c: \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 &gt;200 \u043c\u043a\u041e\u043c<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u043f\u0440\u0438\u0447\u0438\u043d\u0430: \u043e\u043a\u0438\u0441\u043b\u0435\u043d\u0438\u0435 \u0432 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u0435 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0433\u043e \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f.<\/li>\n\n\n\n<li>\u0418\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435: \u043e\u0447\u0438\u0441\u0442\u0438\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b (\u0438\u0437\u043e\u043f\u0440\u043e\u043f\u0438\u043b\u043e\u0432\u044b\u043c \u0441\u043f\u0438\u0440\u0442\u043e\u043c), \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0443 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430.<\/li>\n\n\n\n<li>\u041f\u0440\u043e\u0444\u0438\u043b\u0430\u043a\u0442\u0438\u043a\u0430: \u043c\u0435\u0448\u043a\u0438 \u0434\u043b\u044f \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f, \u0437\u0430\u043f\u043e\u043b\u043d\u0435\u043d\u043d\u044b\u0435 \u0430\u0437\u043e\u0442\u043e\u043c, \u0435\u0436\u0435\u043c\u0435\u0441\u044f\u0447\u043d\u043e \u0432\u043a\u043b\u044e\u0447\u0430\u0439\u0442\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\n\n\n\n<p>\u0412\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0442\u043e, \u0447\u0442\u043e \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0432 \u0445\u043e\u0434\u0435 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439: \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438, \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c \u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044e \u0441 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u0447\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u043e\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430. \u0412 \u043f\u0435\u0440\u0432\u043e\u043e\u0447\u0435\u0440\u0435\u0434\u043d\u043e\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u043c \u0441\u043f\u0438\u0441\u043a\u0435 \u0434\u043b\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043f\u0440\u0438\u043e\u0440\u0438\u0442\u0435\u0442 \u043e\u0442\u0434\u0430\u0435\u0442\u0441\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0431\u043e\u0438 \u2014 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u044c \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438, \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438, \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u2014 \u043f\u0435\u0440\u0435\u0434 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u0446\u0435\u043f\u044f\u043c\u0438.<\/p>\n\n\n\n<p>\u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0438\u043c\u0435\u0435\u0442 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435: \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043d\u0438\u0437\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u043c\u0438, \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439. \u041f\u0440\u043e\u043f\u0443\u0441\u043a \u044d\u0442\u0430\u043f\u043e\u0432 \u0438\u043b\u0438 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043f\u043e\u0440\u044f\u0434\u043a\u0430 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0440\u0438\u0441\u043a \u2014 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u0430\u044f \u0446\u0435\u043f\u044c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043c\u043e\u0436\u0435\u0442 \u043d\u0435\u043e\u0436\u0438\u0434\u0430\u043d\u043d\u043e \u043e\u0442\u043a\u043b\u044e\u0447\u0438\u0442\u044c\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439, \u0438\u043b\u0438 \u043d\u0435\u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u043c\u043e\u0436\u0435\u0442 \u043f\u0435\u0440\u0435\u0433\u043e\u0440\u0435\u0442\u044c \u043f\u0440\u0438 \u043f\u0435\u0440\u0432\u043e\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u0412\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u2014 \u044d\u0442\u043e \u043d\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u043f\u0440\u0438\u0435\u043c\u043e\u0447\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435. \u042d\u0442\u043e \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0435 \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u0432 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445, \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0435\u043c\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u0430\u043c\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0441\u0442\u0440\u043e\u0438\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430. \u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u043c\u0438 \u043a \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044e \u043f\u044b\u043b\u0438, \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u0438, \u043d\u0435\u0445\u0432\u0430\u0442\u043a\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u043d\u0435\u0438\u0437\u0431\u0435\u0436\u043d\u044b\u043c \u043e\u0448\u0438\u0431\u043a\u0430\u043c \u043f\u0440\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435. \u0425\u043e\u0440\u043e\u0448\u043e \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u043d\u0430\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0430 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0442\u044c 95% \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u0434\u043e \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u0433\u0434\u0430 \u0438\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u0437\u0430\u043d\u0438\u043c\u0430\u0435\u0442 \u0447\u0430\u0441\u044b, \u0430 \u043d\u0435 \u043d\u0435\u0434\u0435\u043b\u0438, \u0438 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0437\u0430\u043c\u0435\u043d\u044b \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0434\u0435\u0442\u0430\u043b\u0435\u0439, \u0430 \u043d\u0435 \u0432\u0441\u0435\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vcb-commissioning\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b: \u0412\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e VCB<\/h2>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 1: \u041a\u0430\u043a\u043e\u0435 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e \u0434\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043d\u0430 12 \u043a\u0412 \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f?<\/strong><\/p>\n\n\n\n<p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043d\u0435 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0430\u0431\u0441\u043e\u043b\u044e\u0442\u043d\u044b\u0445 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435, \u043d\u043e \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0432\u043e\u0439 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u043e\u0439 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f &gt;1000 \u041c\u041e\u043c \u043f\u0440\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 2,5 \u043a\u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (\u0436\u0435\u043b\u0430\u0442\u0435\u043b\u044c\u043d\u043e &gt;2000 \u041c\u041e\u043c). \u0417\u043d\u0430\u0447\u0435\u043d\u0438\u044f 100\u20131000 \u041c\u041e\u043c \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u043f\u0440\u0435\u0434\u0435\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u2014 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0432\u043b\u0430\u0433\u0438, \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u043c\u0438\u043a\u0440\u043e\u0442\u0440\u0435\u0449\u0438\u043d \u0432 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u044b\u0445 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430\u0445. \u041f\u0440\u0438 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0438 \u043d\u0438\u0436\u0435 100 \u041c\u041e\u043c \u043d\u0435 \u043f\u043e\u0434\u0430\u0432\u0430\u0439\u0442\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435. \u041f\u0440\u043e\u0441\u0443\u0448\u0438\u0442\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043e\u0442\u0441\u0435\u043a\u0438 \u043f\u0440\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0435 40 \u00b0C \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 8\u201312 \u0447\u0430\u0441\u043e\u0432 \u0438 \u043f\u043e\u0432\u0442\u043e\u0440\u0438\u0442\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435. \u041f\u043e \u043d\u0430\u0448\u0435\u043c\u0443 \u043e\u043f\u044b\u0442\u0443, 8% \u043e\u0442\u0433\u0440\u0443\u0436\u0435\u043d\u043d\u044b\u0445 VCB \u0438\u0437\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 2000 \u041c\u041e\u043c \u0432 90% \u0441\u043b\u0443\u0447\u0430\u0435\u0432. \u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0432\u0435\u0440\u043d\u0443\u0442\u044c \u043d\u0430 \u0437\u0430\u0432\u043e\u0434 \u0434\u043b\u044f \u0437\u0430\u043c\u0435\u043d\u044b \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0440\u0430\u0431\u043e\u0442\u044b \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043e\u043a \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e?<\/strong><\/p>\n\n\n\n<p>\u0412\u0440\u0443\u0447\u043d\u0443\u044e \u043f\u043e\u043f\u0440\u043e\u0431\u0443\u0439\u0442\u0435 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0432\u0441\u0435 \u0437\u0430\u043f\u0440\u0435\u0449\u0435\u043d\u043d\u044b\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438: (1) \u041f\u043e\u043f\u044b\u0442\u0430\u0439\u0442\u0435\u0441\u044c \u0437\u0430\u043a\u0440\u044b\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043f\u0440\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u043e\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u044f\u044e\u0449\u0435\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435 \u2014 \u044d\u0442\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e; (2) \u041f\u043e\u043f\u044b\u0442\u0430\u0439\u0442\u0435\u0441\u044c \u0432\u044b\u0442\u0430\u0449\u0438\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432 \u0437\u0430\u043a\u0440\u044b\u0442\u043e\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438 \u2014 \u044d\u0442\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e; (3) \u041f\u043e\u043f\u044b\u0442\u0430\u0439\u0442\u0435\u0441\u044c \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u043c\u0443 \u043e\u0442\u0441\u0435\u043a\u0443 \u043f\u0440\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u043e\u043c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435 \u2014 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0434\u0432\u0435\u0440\u0446\u044b \u0434\u043e\u043b\u0436\u043d\u0430 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0435\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u0435. \u0421\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEC 62271-200, \u043e\u0434\u043d\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0445 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043e\u043a \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e. \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043a\u0430\u0436\u0434\u0443\u044e \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u043f\u0440\u0438 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u0443\u0441\u0438\u043b\u0438\u0438 \u2014 \u043b\u0435\u0433\u043a\u043e\u0433\u043e \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e; \u043f\u0440\u0438\u043b\u043e\u0436\u0438\u0442\u0435 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0435 \u0443\u0441\u0438\u043b\u0438\u0435, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u043b\u043e\u0436\u0438\u0442\u044c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442 \u043f\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e. 100% \u0437\u0430\u043f\u0440\u0435\u0449\u0435\u043d\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438 \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u044b. \u041e\u0434\u0438\u043d \u0441\u0431\u043e\u0439 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043f\u043e\u043b\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041a\u0430\u043a\u0438\u0435 \u0434\u043e\u043f\u0443\u0441\u043a\u0438 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u044b\u043c\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u0440\u0438 \u0432\u0432\u043e\u0434\u0435 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435?<\/strong><\/p>\n\n\n\n<p>\u041f\u0443\u043d\u043a\u0442 6.111 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 IEC 62271-100 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0434\u043b\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 12 \u043a\u0412 \u043a\u0430\u043a 30\u201360 \u043c\u0441 (\u0432\u0430\u0440\u044c\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043a\u043b\u0430\u0441\u0441\u0430 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u0438). \u0414\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435 \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043e\u0431\u044b\u0447\u043d\u043e \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u00b110% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f. \u041f\u0440\u0438\u043c\u0435\u0440: \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f 50 \u043c\u0441 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 45\u201355 \u043c\u0441. \u0422\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0439 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u043c (\u0440\u0430\u0437\u043d\u0438\u0446\u0430 \u043c\u0435\u0436\u0434\u0443 \u0441\u0430\u043c\u044b\u043c \u0431\u044b\u0441\u0442\u0440\u044b\u043c \u0438 \u0441\u0430\u043c\u044b\u043c \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u044b\u043c \u043f\u043e\u043b\u044e\u0441\u043e\u043c) \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u22643 \u043c\u0441. \u041e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 &gt;15% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0441 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u043c \u2014 \u0443\u0441\u0442\u0430\u043b\u043e\u0441\u0442\u044c \u043f\u0440\u0443\u0436\u0438\u043d\u044b, \u0438\u0437\u043d\u043e\u0441 \u0442\u044f\u0433 \u0438\u043b\u0438 \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u0435 \u0441\u043c\u0430\u0437\u043a\u0438. \u041c\u044b \u0438\u0437\u043c\u0435\u0440\u0438\u043b\u0438 12% \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 VCB, \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0445 \u0434\u043e\u043f\u0443\u0441\u043a\u0438; 90% \u043c\u043e\u0436\u043d\u043e \u0431\u044b\u043b\u043e \u0438\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c \u043f\u0443\u0442\u0435\u043c \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430, 10% \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043b\u0438 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u043e\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430. \u041f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u043e\u0441\u043b\u0435 \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0438 \u0434\u043b\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 5 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 4: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u043f\u0440\u043e\u043f\u0443\u0441\u0442\u0438\u0442\u044c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0443\u044e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435, \u0435\u0441\u043b\u0438 VCB \u0438\u043c\u0435\u0435\u0442 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439?<\/strong><\/p>\n\n\n\n<p>\u041d\u0435\u0442. \u0417\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0435 \u0440\u0443\u0442\u0438\u043d\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u0432 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445; \u0432\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0435\u0442 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443 \u043f\u043e\u0441\u043b\u0435 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0438, \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0438 \u0441\u0431\u043e\u0440\u043a\u0438 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435. \u0422\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u044b\u0435 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044e \u043c\u0438\u043a\u0440\u043e\u0442\u0440\u0435\u0449\u0438\u043d \u0432 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u044b\u0445 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430\u0445 (\u043d\u0435\u0432\u0438\u0434\u0438\u043c\u044b\u0445 \u043f\u0440\u0438 \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u043e\u043c \u043e\u0441\u043c\u043e\u0442\u0440\u0435). \u041e\u0448\u0438\u0431\u043a\u0438 \u043f\u0440\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435 \u2014 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435 \u043a\u0430\u0431\u0435\u043b\u0435\u0439, \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u043e\u0432, \u043f\u043e\u043f\u0430\u0434\u0430\u043d\u0438\u0435 \u0432\u043b\u0430\u0433\u0438 \u2014 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u0440\u0438\u0441\u043a \u043f\u0440\u043e\u0431\u043e\u044f, \u043a\u043e\u0442\u043e\u0440\u043e\u0433\u043e \u043d\u0435\u0442 \u043f\u0440\u0438 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u044f \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439; \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-200 (\u0434\u043b\u044f \u043f\u043e\u043b\u043d\u044b\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a) \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u0440\u0438 \u0432\u0432\u043e\u0434\u0435 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043d\u0430 \u043c\u0435\u0441\u0442\u0435. \u0422\u0438\u043f\u0438\u0447\u043d\u0430\u044f \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0430: 80% \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u043e\u0433\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 1 \u043c\u0438\u043d\u0443\u0442\u044b (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, 28 \u043a\u0412 \u00d7 0,8 = 22,4 \u043a\u0412 \u0434\u043b\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f 12 \u043a\u0412). \u041c\u044b \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u043b\u0438 \u0434\u0435\u0444\u0435\u043a\u0442\u044b \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0432 5% \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u0432\u043e\u0434\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u043e\u0448\u043b\u0438 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 5: \u041a\u0430\u043a\u0438\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u044b \u044f \u0434\u043e\u043b\u0436\u0435\u043d \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c, \u043f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u043f\u0440\u0438\u043d\u044f\u0442\u044c VCB \u043d\u0430 \u043c\u0435\u0441\u0442\u0435?<\/strong><\/p>\n\n\n\n<p>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f: (1) \u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043e\u0442 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 (KEMA, CESI, CPRI), \u0442\u043e\u0447\u043d\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0439 \u043a\u043b\u0430\u0441\u0441\u0443 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f; (2) \u041e\u0442\u0447\u0435\u0442 \u043e \u043f\u043b\u0430\u043d\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0441\u0435\u0440\u0438\u0439\u043d\u043e\u0433\u043e \u043d\u043e\u043c\u0435\u0440\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430; (3) \u0427\u0435\u0440\u0442\u0435\u0436\u0438 CAD \u0441 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u044b\u043c\u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u0430\u043c\u0438 \u0438 \u0437\u0430\u0437\u043e\u0440\u0430\u043c\u0438; (4) \u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u043d\u0430 \u044f\u0437\u044b\u043a\u0435 \u043e\u0431\u044a\u0435\u043a\u0442\u0430; (5) \u0421\u043f\u0438\u0441\u043e\u043a \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u0441\u0440\u043e\u043a\u043e\u0432 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0438. \u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u043e: \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0434\u043e\u043b\u0436\u0435\u043d \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u2014 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u043d\u0430 \u201c12 \u043a\u0412, 25 \u043a\u0410\u201d \u043d\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0435\u0442 \u201c12 \u043a\u0412, 31,5 \u043a\u0410\u201d (\u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u043a\u043b\u0430\u0441\u0441\u044b \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439). \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043f\u0440\u043e\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0438\u0439\u043d\u043e\u0433\u043e \u043d\u043e\u043c\u0435\u0440\u0430: \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0430 \u2192 \u043e\u0442\u0447\u0435\u0442 \u043e \u043f\u043b\u0430\u043d\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445 \u2192 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u0430\u044f \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f. \u041c\u044b \u043e\u0442\u043a\u043b\u043e\u043d\u0438\u043b\u0438 12% \u043f\u043e\u0441\u0442\u0430\u0432\u043e\u043a \u0438\u0437-\u0437\u0430 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445\/\u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432; \u0438\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u0442\u0430\u0432\u0449\u0438\u043a\u043e\u043c \u0437\u0430\u043d\u044f\u043b\u043e \u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u043c 3-8 \u043d\u0435\u0434\u0435\u043b\u044c.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 6: \u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0444\u0443\u043d\u043a\u0446\u0438\u044e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043d\u0430\u043a\u0430\u0447\u043a\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e?<\/strong><\/p>\n\n\n\n<p>\u0410\u043d\u0442\u0438\u043f\u043e\u043c\u043f\u0438\u043d\u0433 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0432\u0442\u043e\u0440\u044f\u044e\u0449\u0438\u0435\u0441\u044f \u0446\u0438\u043a\u043b\u044b \u201c\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435-\u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435-\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u201d, \u043a\u043e\u0433\u0434\u0430 \u043a\u043d\u043e\u043f\u043a\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0432 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438. \u0422\u0435\u0441\u0442: (1) \u0417\u0430\u0440\u044f\u0434\u0438\u0442\u0435 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u0439\u0442\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432 \u043e\u0431\u044b\u0447\u043d\u043e\u043c \u0440\u0435\u0436\u0438\u043c\u0435; (2) \u0423\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0439\u0442\u0435 \u043a\u043d\u043e\u043f\u043a\u0443\/\u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432 \u043d\u0430\u0436\u0430\u0442\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438; (3) \u0412\u044b\u0434\u0430\u0439\u0442\u0435 \u043a\u043e\u043c\u0430\u043d\u0434\u0443 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u043a\u043d\u043e\u043f\u043a\u0430 \u0438\u043b\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0440\u0435\u043b\u0435); (4) \u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0434\u043e\u043b\u0436\u0435\u043d \u043e\u0442\u043a\u043b\u044e\u0447\u0438\u0442\u044c\u0441\u044f \u0438 \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438, \u043f\u043e\u043a\u0430 \u043a\u043d\u043e\u043f\u043a\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0432 \u043d\u0430\u0436\u0430\u0442\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438; (5) \u041e\u0442\u043f\u0443\u0441\u043a\u0430\u043d\u0438\u0435 \u0438 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u043d\u0430\u0436\u0430\u0442\u0438\u0435 \u043a\u043d\u043e\u043f\u043a\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043e\u043b\u0436\u043d\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0442\u043e\u043b\u044c\u043a\u043e \u043e\u0434\u043d\u0443 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f. \u0420\u0435\u0436\u0438\u043c \u043e\u0442\u043a\u0430\u0437\u0430: \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u00ab\u043a\u0430\u0447\u0430\u0435\u0442\u00bb (\u043f\u043e\u0432\u0442\u043e\u0440\u044f\u044e\u0449\u0438\u0435\u0441\u044f \u0446\u0438\u043a\u043b\u044b \u00ab\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435-\u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435-\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u00bb), \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u0423\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435: \u043e\u0442\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u0440\u0435\u043b\u0435 \u0430\u043d\u0442\u0438\u043a\u0430\u0447\u043a\u0438 (\u043e\u0431\u044b\u0447\u043d\u043e \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 52a\/52b) \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u0435, \u0435\u0441\u043b\u0438 \u043e\u043d\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0442\u0438\u043f\u0430. \u041f\u0440\u043e\u0432\u0435\u0434\u0438\u0442\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0441 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435 \u2014 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0446\u0435\u043f\u0438 \u0430\u043d\u0442\u0438\u043a\u0430\u0447\u043a\u0438 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b \u043a \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e. \u041c\u044b \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u043b\u0438, \u0447\u0442\u043e \u0432 8% \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a \u0430\u043d\u0442\u0438\u043a\u0430\u0447\u043a\u0430 \u0431\u044b\u043b\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0430\/\u043e\u0431\u0445\u043e\u0434\u0438\u043b\u0430\u0441\u044c \u0438\u0437-\u0437\u0430 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0449\u0438\u043a\u043e\u043c.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 7: \u041a\u0430\u043a\u043e\u0435 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e \u043d\u0430 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f\u0445 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0434 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439?<\/strong><\/p>\n\n\n\n<p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u043e\u0441\u0442 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0432\u044b\u0448\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b: \u043c\u0435\u0434\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b &lt;75 K, \u043f\u043e\u0441\u0435\u0440\u0435\u0431\u0440\u0435\u043d\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b &lt;80 K, \u0431\u043e\u043b\u0442\u043e\u0432\u044b\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0448\u0438\u043d 50 K \u0432\u044b\u0448\u0435 \u0441\u043e\u0441\u0435\u0434\u043d\u0438\u0445 \u043e\u0431\u043b\u0430\u0441\u0442\u0435\u0439 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b: \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043a\u0440\u0443\u0442\u044f\u0449\u0438\u0439 \u043c\u043e\u043c\u0435\u043d\u0442 (\u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e \u0437\u0430\u0442\u044f\u043d\u0438\u0442\u0435 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438, \u043e\u0431\u044b\u0447\u043d\u043e 40-60 \u041d\u22c5\u043c \u0434\u043b\u044f \u0448\u043f\u0438\u043b\u0435\u043a M12), \u043e\u043a\u0441\u0438\u0434\u043d\u044b\u0439 \u0441\u043b\u043e\u0439 \u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438 (\u0440\u0430\u0437\u0431\u0435\u0440\u0438\u0442\u0435, \u043e\u0447\u0438\u0441\u0442\u0438\u0442\u0435 \u0438\u0437\u043e\u043f\u0440\u043e\u043f\u0438\u043b\u043e\u0432\u044b\u043c \u0441\u043f\u0438\u0440\u0442\u043e\u043c, \u0441\u043e\u0431\u0435\u0440\u0438\u0442\u0435 \u0437\u0430\u043d\u043e\u0432\u043e) \u0438\u043b\u0438 \u043d\u0435\u0441\u043e\u043e\u0441\u043d\u043e\u0441\u0442\u044c (\u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043f\u043e\u0441\u0430\u0434\u043a\u0443 \u0448\u0438\u043d\u044b \u043d\u0430 \u043a\u043b\u0435\u043c\u043c\u0435). \u0412 \u0445\u043e\u0434\u0435 \u043d\u0430\u0448\u0438\u0445 \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u0445 \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0439 200 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a, 10% \u043f\u0440\u043e\u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u043e\u0432\u0430\u043b \u0433\u043e\u0440\u044f\u0447\u0438\u0435 \u0442\u043e\u0447\u043a\u0438 \u0438\u0437-\u0437\u0430 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u0437\u0430\u0442\u044f\u0436\u043a\u0438; 3% \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043b \u043f\u0435\u0440\u0435\u0434\u0435\u043b\u043a\u0438 \u0448\u0438\u043d\u044b \u0434\u043b\u044f \u0432\u044b\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u043d\u0438\u044f. \u041e\u0431\u043d\u0430\u0440\u0443\u0436\u044c\u0442\u0435 \u044d\u0442\u0438 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043f\u0435\u0440\u0432\u044b\u0445 30 \u0434\u043d\u0435\u0439, \u043f\u043e\u043a\u0430 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0435 \u0443\u0441\u0443\u0433\u0443\u0431\u0438\u043b\u0438\u0441\u044c.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum circuit breaker commissioning failures don\u2019t announce themselves during factory acceptance tests. They surface at site energization when auxiliary contacts chatter due to vibration, when timing tests reveal 90 ms opening instead of the specified 60 ms, or when documentation gaps delay project handover by weeks while the contractor scrambles to produce missing certificates. These [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2404,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24,27],"tags":[],"class_list":["post-2401","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2401"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2401\/revisions"}],"predecessor-version":[{"id":3577,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2401\/revisions\/3577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2404"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}