{"id":2409,"date":"2026-01-03T08:28:34","date_gmt":"2026-01-03T08:28:34","guid":{"rendered":"https:\/\/xbrele.com\/?p=2409"},"modified":"2026-04-07T13:32:04","modified_gmt":"2026-04-07T13:32:04","slug":"transformer-inrush-current-nuisance-trips-prevention","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/transformer-inrush-current-nuisance-trips-prevention\/","title":{"rendered":"\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0438 \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f: \u043f\u0440\u0438\u0447\u0438\u043d\u044b \u0438 \u0441\u043f\u043e\u0441\u043e\u0431\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f"},"content":{"rendered":"<p>\u041f\u043e\u0434\u0430\u0447\u0430 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u043e\u0439 \u043f\u0440\u0438\u0447\u0438\u043d\u043e\u0439 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u041c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a \u0434\u043e\u043b\u0436\u0435\u043d \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u0442\u044c \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u043f\u0440\u0438 \u043f\u043e\u0434\u0430\u0447\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0438 \u0435\u0441\u043b\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432\u0431\u043b\u0438\u0437\u0438 \u043d\u0443\u043b\u0435\u0432\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u0430 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0444\u043e\u0440\u043c\u0430 \u0432\u043e\u043b\u043d\u044b \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u043e\u0439, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0433\u043b\u0443\u0431\u043e\u043a\u043e\u043c\u0443 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044e \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430. \u041c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u0442\u043e\u043a \u0440\u0435\u0437\u043a\u043e \u0432\u043e\u0437\u0440\u0430\u0441\u0442\u0430\u0435\u0442 \u0441 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f 0,5-21 \u0422\u041f3\u0422 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043e 8-15\u00d7 \u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043f\u0440\u0438 \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435, \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 0,1-0,5 \u0441\u0435\u043a\u0443\u043d\u0434, \u0430 \u0437\u0430\u0442\u0435\u043c \u044d\u043a\u0441\u043f\u043e\u043d\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0437\u0430\u0442\u0443\u0445\u0430\u0435\u0442. \u042d\u0442\u043e \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0435 \u044f\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u043e\u0440\u043e\u0433\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u043b\u043e\u0445\u043e \u0441\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u0432\u044b\u0437\u044b\u0432\u0430\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 \u043c\u043d\u0438\u043c\u044b\u0435 \u201c\u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438\u201d, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0430 \u0441\u0430\u043c\u043e\u043c \u0434\u0435\u043b\u0435 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u043c \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u044f\u0432\u043b\u0435\u043d\u0438\u0435\u043c.<\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 \u0443\u0441\u0443\u0433\u0443\u0431\u043b\u044f\u0435\u0442\u0441\u044f \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c (ATS), \u0433\u0434\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0447\u0430\u0441\u0442\u043e \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f, \u0438\u043b\u0438 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438, \u0433\u0434\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a. \u041d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435 \u0441 \u0442\u0440\u0435\u043c\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c\u044e 2000 \u043a\u0412\u0410 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442\u044c 15\u201320 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u0432 \u0433\u043e\u0434 \u0442\u043e\u043b\u044c\u043a\u043e \u0438\u0437-\u0437\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u043a\u0430\u0436\u0434\u043e\u0435 \u0438\u0437 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043f\u0440\u043e\u0441\u0442\u043e\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430, \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u043d\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438\u0437-\u0437\u0430 \u043f\u043e\u0432\u0442\u043e\u0440\u044f\u044e\u0449\u0438\u0445\u0441\u044f \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u0438 \u0432\u044b\u0437\u043e\u0432\u0430\u043c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u201c\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439\u201d, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0438\u043a\u043e\u0433\u0434\u0430 \u043d\u0435 \u0432\u043e\u0441\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u044f\u0442\u0441\u044f \u043f\u0440\u0438 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438.<\/p>\n\n\n\n<p>\u0412 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0430\u0441\u043f\u0435\u043a\u0442\u044b \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432, \u0444\u0430\u043a\u0442\u043e\u0440\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0434\u0435\u043b\u0430\u044e\u0442 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0445\u0443\u0436\u0435 \u0434\u0440\u0443\u0433\u0438\u0445, \u0430 \u0442\u0430\u043a\u0436\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u0438 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u044e\u0442 90%+ \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0445 \u0441 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0442\u043e\u043a\u043e\u043c, \u0431\u0435\u0437 \u0443\u0449\u0435\u0440\u0431\u0430 \u0434\u043b\u044f \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430: \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e Harmonic Block\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/5aj8nbikJns?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-transformer-inrush-exceeds-normal-magnetizing-current\">\u041f\u043e\u0447\u0435\u043c\u0443 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f<\/h2>\n\n\n\n<p>\u0412\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u0440\u0435\u0436\u0438\u043c\u0435 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043d\u0435\u0432\u0435\u043b\u0438\u043a \u2014 0,5\u201321 \u0422\u041f3\u0422 \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043b\u044f \u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432. \u042d\u0442\u043e\u0442 \u0442\u043e\u043a \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u044b\u0439 \u0434\u043b\u044f \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u043e \u0437\u0430\u043a\u043e\u043d\u0443 \u0424\u0430\u0440\u0430\u0434\u0435\u044f. \u041f\u0440\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0447\u0430\u0441\u0442\u044c \u043f\u043e\u0442\u043e\u043a\u0430 \u043e\u0441\u0442\u0430\u0435\u0442\u0441\u044f \u0432 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435 (\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0441\u0442\u044c), \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044f \u043e\u0442 30 \u0434\u043e 801 \u0422\u041f3\u0422 \u043e\u0442 \u043f\u0438\u043a\u043e\u0432\u043e\u0433\u043e \u0440\u0430\u0431\u043e\u0447\u0435\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0441\u0432\u043e\u0439\u0441\u0442\u0432 \u0441\u0442\u0430\u043b\u0438 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430.<\/p>\n\n\n\n<p>\u041f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0432 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u0445 \u0441\u043b\u0443\u0447\u0430\u044f\u0445:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a<\/strong>\u00a0\u0432\u044b\u0441\u043e\u043a\u0438\u0439 (80% \u043e\u0442 \u03a6_max)<\/li>\n\n\n\n<li><strong>\u041c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/strong>\u00a0\u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0438 \u043d\u0443\u043b\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/li>\n\n\n\n<li><strong>\u041f\u043e\u043b\u044f\u0440\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0442\u043e\u043a\u0430<\/strong>\u00a0\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0438 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0441\u043e\u0432\u043f\u0430\u0434\u0430\u044e\u0442 (\u0430\u0434\u0434\u0438\u0442\u0438\u0432\u043d\u044b\u0435)<\/li>\n<\/ol>\n\n\n\n<p>\u0412 \u044d\u0442\u0438\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043e\u0431\u0449\u0438\u0439 \u0441\u043f\u0440\u043e\u0441 \u043d\u0430 \u043f\u043e\u0442\u043e\u043a\u0438 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442:<br>\u03a6<sub>\u0432\u0441\u0435\u0433\u043e<\/sub>\u00a0= \u03a6<sub>\u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u043d\u044b\u0439<\/sub>\u00a0+ \u03a6<sub>\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439<\/sub>\u00a0\u2248 1,0 + 0,8 =\u00a0<strong>1,8 \u043f.\u0435.<\/strong><br><br>\u041d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0435 \u044f\u0434\u0440\u0430 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u043f\u0440\u0438 ~1,2\u20131,3 \u0435.\u0435., \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u043f\u043e\u0442\u0440\u0435\u0431\u043d\u043e\u0441\u0442\u044c \u0432 1,8 \u0435.\u0435. \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0433\u043b\u0443\u0431\u043e\u043a\u043e\u043c\u0443 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044e \u044f\u0434\u0440\u0430. \u041f\u0440\u0438 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0438 \u043f\u0440\u043e\u043d\u0438\u0446\u0430\u0435\u043c\u043e\u0441\u0442\u044c \u043f\u0430\u0434\u0430\u0435\u0442 \u2014 \u0441\u043e\u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043f\u043e\u0442\u043e\u043a\u043e\u043c \u0438 \u0442\u043e\u043a\u043e\u043c \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u043d\u0435\u043b\u0438\u043d\u0435\u0439\u043d\u044b\u043c, \u0438 \u0434\u043b\u044f \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u0435\u043c\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0442\u043e\u043a\u0430. [HTML-<\/p>\n\n\n\n<p><strong>\u041f\u0438\u043a\u043e\u0432\u0430\u044f \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/strong>: \u041e\u0431\u044b\u0447\u043d\u043e 8-12\u00d7 \u0442\u043e\u043a \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 (200 \u043a\u0412\u0410 \u2013 2500 \u043a\u0412\u0410). \u0411\u043e\u043b\u044c\u0448\u0438\u0435 \u0441\u0438\u043b\u043e\u0432\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b (&gt;10 \u041c\u0412\u0410) \u043c\u043e\u0433\u0443\u0442 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0442\u044c 15-20\u00d7 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u043c\u0443 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0443 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 (\u043c\u0435\u043d\u044c\u0448\u0438\u0435 \u043f\u043e\u0442\u0435\u0440\u0438, \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0449\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0442\u043e\u043a\u0430).<\/p>\n\n\n\n<p><strong>\u041f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u0430\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0440\u0430\u0441\u043f\u0430\u0434\u0430<\/strong>: \u041e\u0431\u0443\u0441\u043b\u043e\u0432\u043b\u0435\u043d\u043e \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u043e\u0431\u043c\u043e\u0442\u043a\u0438 \u0438 \u043f\u043e\u0442\u0435\u0440\u044f\u043c\u0438 \u0432 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0435. \u041c\u0435\u043d\u044c\u0448\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0437\u0430\u0442\u0443\u0445\u0430\u044e\u0442 \u0431\u044b\u0441\u0442\u0440\u0435\u0435 (50\u2013200 \u043c\u0441), \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430 \u0435\u0434\u0438\u043d\u0438\u0446\u0443 \u0433\u0430\u0441\u0438\u0442 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u044b. \u0411\u043e\u043b\u0435\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u043e\u043b\u044c\u0448\u0435 (200\u2013500 \u043c\u0441).<\/p>\n\n\n\n<p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/transformer-impedance-percentage-guide\/\">\u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 Z%<\/a>&nbsp;\u043f\u043e\u043c\u043e\u0433\u0430\u0435\u0442 \u043f\u043e\u043d\u044f\u0442\u044c, \u043f\u043e\u0447\u0435\u043c\u0443 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442\u0441\u044f \u043e\u0442 \u0442\u043e\u043a\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u2014 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u043c \u044f\u0432\u043b\u0435\u043d\u0438\u0435\u043c, \u0442\u043e\u0433\u0434\u0430 \u043a\u0430\u043a \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0447\u0438\u0441\u0442\u043e \u0440\u0435\u0437\u0438\u0441\u0442\u0438\u0432\u043d\u044b\u043c\/\u0440\u0435\u0430\u043a\u0442\u0438\u0432\u043d\u044b\u043c.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01.webp\" alt=\"\u0413\u0440\u0430\u0444\u0438\u043a, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043f\u043e\u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0441 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u043c \u043f\u043e\u0442\u043e\u043a\u043e\u043c \u0438 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0435\u043c \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430, \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u043c \u043f\u0438\u043a\u043e\u0432\u044b\u0439 \u043f\u043e\u0442\u043e\u043a 1,8 \u0435\u0434\u0438\u043d\u0438\u0446.\" class=\"wp-image-2410\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 1. \u041f\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u043f\u043e\u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043f\u0440\u0438 \u043d\u0430\u0438\u0445\u0443\u0434\u0448\u0435\u043c \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u0435 \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f: \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a (0,8 \u0435\u0434.) \u043f\u043b\u044e\u0441 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0438 \u043d\u0443\u043b\u044f \u043f\u0440\u0438\u0432\u043e\u0434\u044f\u0442 \u043a \u043e\u0431\u0449\u0435\u043c\u0443 \u043f\u043e\u0442\u043e\u043a\u0443 1,8 \u0435\u0434., \u0447\u0442\u043e \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u043e\u0440\u043e\u0433 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f (1,2 \u0435\u0434.) \u0438 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043c\u0430\u0441\u0441\u0438\u0432\u043d\u044b\u0439 \u0432\u0441\u043f\u043b\u0435\u0441\u043a \u0442\u043e\u043a\u0430 \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"harmonic-content-the-key-to-discrimination\">\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u043e\u0441\u0442\u0430\u0432: \u043a\u043b\u044e\u0447 \u043a \u0440\u0430\u0437\u043b\u0438\u0447\u0435\u043d\u0438\u044e<\/h2>\n\n\n\n<p>\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0441\u043e\u0434\u0435\u0440\u0436\u0438\u0442 \u0432\u0442\u043e\u0440\u0443\u044e \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0443 30-70% (100 \u0413\u0446 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 50 \u0413\u0446, 120 \u0413\u0446 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 60 \u0413\u0446), \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0444\u043e\u0440\u043c\u0430 \u0432\u043e\u043b\u043d\u044b \u043f\u043e\u0442\u043e\u043a\u0430 \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u0430 \u2014 \u043e\u043d\u0430 \u043d\u0430\u0441\u044b\u0449\u0430\u0435\u0442\u0441\u044f \u043d\u0430 \u043e\u0434\u043d\u043e\u043c \u043f\u043e\u043b\u0443\u0446\u0438\u043a\u043b\u0435, \u043d\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043b\u0438\u043d\u0435\u0439\u043d\u043e \u043d\u0430 \u0434\u0440\u0443\u0433\u043e\u043c. \u042d\u0442\u0430 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430 \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043e\u0442 \u043f\u043e\u0434\u043b\u0438\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u0438\u043c\u0435\u0435\u0442 \u043e\u0441\u043d\u043e\u0432\u043d\u0443\u044e \u0447\u0430\u0441\u0442\u043e\u0442\u0443.<\/p>\n\n\n\n<p><strong>\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 \u0442\u0438\u043f\u0438\u0447\u043d\u043e\u0433\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0424\u0443\u043d\u0434\u0430\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u044b\u0439 (50\/60 \u0413\u0446)<\/strong>: 100% (\u0441\u0441\u044b\u043b\u043a\u0430)<\/li>\n\n\n\n<li><strong>\u0412\u0442\u043e\u0440\u0430\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0430<\/strong>: 30-70% (\u0434\u043e\u043c\u0438\u043d\u0438\u0440\u0443\u044e\u0449\u0430\u044f \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u044c)<\/li>\n\n\n\n<li><strong>\u0422\u0440\u0435\u0442\u044c\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0430<\/strong>: 10-20%<\/li>\n\n\n\n<li><strong>\u0412\u044b\u0441\u0448\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438<\/strong>: &lt;5%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u043e\u0441\u0442\u0430\u0432 \u0442\u043e\u043a\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0424\u0443\u043d\u0434\u0430\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u044b\u0439<\/strong>: 100%<\/li>\n\n\n\n<li><strong>\u0412\u0442\u043e\u0440\u0430\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0430<\/strong>: &lt;5% (\u043d\u0435\u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e)<\/li>\n<\/ul>\n\n\n\n<p>\u042d\u0442\u043e \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442&nbsp;<strong>\u0440\u0435\u043b\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0439<\/strong>&nbsp;\u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u0420\u0435\u043b\u0435 \u0438\u0437\u043c\u0435\u0440\u044f\u0435\u0442 \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u0432\u0442\u043e\u0440\u043e\u0433\u043e \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043a \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u043c\u0443 \u0442\u043e\u043a\u0443. \u0415\u0441\u043b\u0438 \u044d\u0442\u043e \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u043e\u0440\u043e\u0433\u043e\u0432\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 (\u043e\u0431\u044b\u0447\u043d\u043e 15-20%), \u0440\u0435\u043b\u0435 \u0438\u043d\u0442\u0435\u0440\u043f\u0440\u0435\u0442\u0438\u0440\u0443\u0435\u0442 \u044d\u0442\u043e \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043a\u0430\u043a \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 \u0437\u0430\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u043f\u0435\u0440\u0438\u043e\u0434 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 (0,5-2 \u0441\u0435\u043a\u0443\u043d\u0434\u044b).<\/p>\n\n\n\n<p><strong>\u041b\u043e\u0433\u0438\u043a\u0430 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0441\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u043d\u0438\u044f (\u0443\u043f\u0440\u043e\u0449\u0435\u043d\u043d\u0430\u044f)<\/strong>:<br>\u0415\u0421\u041b\u0418 (I<sub>2-\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0430<\/sub>\u00a0\/ I<sub>\u0444\u0443\u043d\u0434\u0430\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u044b\u0439<\/sub>) &gt; 0,18 \u0422\u041e\u0413\u0414\u0410<br>\u00a0\u00a0\u0411\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f (50\/51)<br>\u00a0\u00a0\u0417\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u043e \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0435 \u043f\u043e \u0442\u043e\u043a\u0443 \u043d\u0430 0,5-1,0 \u0441<br>ELSE<br>\u00a0\u00a0\u041d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u0437\u0430\u0449\u0438\u0442\u044b<br>\u041a\u041e\u041d\u0415\u0426 IF<\/p>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 95 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u043b\u043e \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u043e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043d\u0430 85-95% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0440\u043e\u0441\u0442\u044b\u043c \u0442\u043e\u043a\u043e\u0432\u044b\u043c \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e\u043c \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u043d\u0435 \u0443\u0445\u0443\u0434\u0448\u0430\u044f \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u043f\u0440\u0438 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\u0445.<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u043b\u043d\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u043e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u043c.&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/transformer-protection-vcb-inrush-coordination-mistakes\/\">\u0437\u0430\u0449\u0438\u0442\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0441 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430\u043c\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 VCB<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"factors-that-worsen-inrush-transformer-design-and-system-conditions\">\u0424\u0430\u043a\u0442\u043e\u0440\u044b, \u0443\u0445\u0443\u0434\u0448\u0430\u044e\u0449\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a: \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/h2>\n\n\n\n<p>\u041d\u0435 \u0432\u0441\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0442 \u043e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a. \u0428\u0435\u0441\u0442\u044c \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u0435\u0433\u043e \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0441\u0442\u044c:<\/p>\n\n\n\n<p><strong>1. \u041a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041a\u0440\u0438\u0441\u0442\u0430\u043b\u043b\u0438\u0447\u0435\u0441\u043a\u0438 \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043a\u0440\u0435\u043c\u043d\u0438\u0435\u0432\u0430\u044f \u0441\u0442\u0430\u043b\u044c (CRGO)<\/strong>: \u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u043f\u0440\u043e\u043d\u0438\u0446\u0430\u0435\u043c\u043e\u0441\u0442\u044c, \u043c\u0435\u043d\u044c\u0448\u0438\u0435 \u043f\u043e\u0442\u0435\u0440\u0438 \u2192 \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0435\u0442 60-80% \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u2192 \u0445\u0443\u0434\u0448\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a<\/li>\n\n\n\n<li><strong>\u0410\u043c\u043e\u0440\u0444\u043d\u044b\u0435 \u043c\u0435\u0442\u0430\u043b\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0438<\/strong>: \u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0439 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a (30-50%) \u2192 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u043d\u043e \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0411\u043e\u043b\u0435\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b (&gt;2500 \u043a\u0412\u0410) \u0438\u043c\u0435\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430 \u0435\u0434\u0438\u043d\u0438\u0446\u0443 \u2192 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0435 \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u044f \u2192 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a<\/li>\n<\/ul>\n\n\n\n<p><strong>3. \u041e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u043f\u0440\u0438 \u0441\u043d\u044f\u0442\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0415\u0441\u0442\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f (\u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u0435\u0442\u0441\u044f \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u044b\u043c \u043e\u0431\u0440\u0430\u0437\u043e\u043c): \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u043a\u043e\u043b\u0435\u0431\u043b\u0435\u0442\u0441\u044f \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 30\u201380%.<\/li>\n\n\n\n<li>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 (\u043e\u0442\u043a\u0440\u044b\u0442\u0438\u0435 \u043f\u0440\u0438 \u043d\u0443\u043b\u0435\u0432\u043e\u043c \u0442\u043e\u043a\u0435): \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a ~80% (\u043d\u0430\u0438\u0445\u0443\u0434\u0448\u0438\u0439 \u0441\u043b\u0443\u0447\u0430\u0439)<\/li>\n<\/ul>\n\n\n\n<p><strong>4. \u0418\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0416\u0435\u0441\u0442\u043a\u0438\u0439 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a<\/strong>\u00a0(\u043d\u0438\u0437\u043a\u0438\u0439 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441, \u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440): \u043f\u0438\u043a \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d \u0442\u043e\u043b\u044c\u043a\u043e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0435\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u2192 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043f\u0438\u043a\u0438<\/li>\n\n\n\n<li><strong>\u0421\u043b\u0430\u0431\u044b\u0439 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a<\/strong>\u00a0(\u0434\u043b\u0438\u043d\u043d\u044b\u0439 \u043f\u0438\u0442\u0430\u044e\u0449\u0438\u0439 \u043a\u0430\u0431\u0435\u043b\u044c, \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u0441\u0438\u043b\u043e\u0432\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440): \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u0433\u0430\u0441\u0438\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u2192 \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u043f\u0438\u043a\u0438, \u043d\u043e \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/li>\n<\/ul>\n\n\n\n<p><strong>5. \u0423\u0433\u043e\u043b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0435 \u043d\u0443\u043b\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: \u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u044b\u0439 \u0442\u043e\u043a \u2192 \u043d\u0430\u0438\u0445\u0443\u0434\u0448\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a<\/li>\n\n\n\n<li><strong>\u041f\u0438\u043a \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>: \u0421\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u043e\u0435 \u043d\u0430\u0440\u0430\u0441\u0442\u0430\u043d\u0438\u0435 \u0442\u043e\u043a\u0430 \u2192 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a (1-2\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a)<\/li>\n<\/ul>\n\n\n\n<p><strong>6. \u041f\u0440\u0435\u0434\u044b\u0434\u0443\u0449\u0430\u044f \u0438\u0441\u0442\u043e\u0440\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0440\u0430\u0431\u043e\u0442\u0430\u043b \u0441 \u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439 \u043f\u0435\u0440\u0435\u0434 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u043f\u0438\u0442\u0430\u043d\u0438\u044f: \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a<\/li>\n\n\n\n<li>\u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440, \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0438\u0439 \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u0445\u043e\u043b\u043e\u0441\u0442\u043e\u0433\u043e \u0445\u043e\u0434\u0430: \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0439 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02.webp\" alt=\"\u0413\u0438\u0441\u0442\u043e\u0433\u0440\u0430\u043c\u043c\u0430, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0448\u0435\u0441\u0442\u044c \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u0432\u043b\u0438\u044f\u044e\u0449\u0438\u0445 \u043d\u0430 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430, \u0441 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u043c \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u0438 \u0443\u0433\u043b\u043e\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0445 \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432.\" class=\"wp-image-2413\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 2. \u0428\u0435\u0441\u0442\u044c \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432, \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0449\u0438\u0445 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430: \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 (\u0432\u043a\u043b\u0430\u0434 60-80% \u0437\u0430 \u0441\u0447\u0435\u0442 \u0443\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430), \u0443\u0433\u043e\u043b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u0440\u0430\u0437\u043d\u0438\u0446\u0430 50% \u043c\u0435\u0436\u0434\u0443 \u043d\u0430\u0438\u0445\u0443\u0434\u0448\u0438\u043c \u0441\u043b\u0443\u0447\u0430\u0435\u043c \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u044f \u043d\u0443\u043b\u044f \u0438 \u043d\u0430\u0438\u043b\u0443\u0447\u0448\u0438\u043c \u0441\u043b\u0443\u0447\u0430\u0435\u043c \u043f\u0438\u043a\u043e\u0432\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f) \u0438 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u0443 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-coordination-strategies-to-prevent-nuisance-trips\">\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043b\u043e\u0436\u043d\u044b\u0445 \u0432\u044b\u0435\u0437\u0434\u043e\u0432<\/h2>\n\n\n\n<p>\u041f\u044f\u0442\u044c \u043f\u043e\u0434\u0445\u043e\u0434\u043e\u0432, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0438\u0445 \u0443\u0441\u0442\u0440\u0430\u043d\u0438\u0442\u044c \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0441 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0442\u043e\u043a\u043e\u043c, \u043f\u0435\u0440\u0435\u0447\u0438\u0441\u043b\u0435\u043d\u044b \u043e\u0442 \u0441\u0430\u043c\u043e\u0433\u043e \u043f\u0440\u043e\u0441\u0442\u043e\u0433\u043e (\u043d\u043e \u043d\u0430\u0438\u043c\u0435\u043d\u0435\u0435 \u0438\u0437\u0431\u0438\u0440\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e) \u0434\u043e \u0441\u0430\u043c\u043e\u0433\u043e \u0441\u043b\u043e\u0436\u043d\u043e\u0433\u043e:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-1-time-delayed-overcurrent\">\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u044f 1: \u0417\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0435 \u043f\u043e \u0442\u043e\u043a\u0443<\/h3>\n\n\n\n<p>\u0423\u0432\u0435\u043b\u0438\u0447\u044c\u0442\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043d\u0430 \u0440\u0435\u043b\u0435 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443, \u0447\u0442\u043e\u0431\u044b \u043f\u0440\u0435\u0432\u044b\u0441\u0438\u0442\u044c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0441\u043f\u0430\u0434\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u0414\u043b\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c\u044e 1000\u20132500 \u043a\u0412\u0410 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043d\u0430 0,5\u20131,0 \u0441\u0435\u043a\u0443\u043d\u0434\u044b.<\/p>\n\n\n\n<p><strong>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u0440\u043e\u0441\u0442\u043e\u0442\u0430 \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 (\u0432\u0441\u0435 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0435 \u0440\u0435\u043b\u0435 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f)<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f<\/li>\n\n\n\n<li>\u0420\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0441 \u043b\u044e\u0431\u044b\u043c \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u043c<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u043e\u0434\u043b\u0438\u043d\u043d\u044b\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0442\u0430\u043a\u0436\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u043d\u0430 0,5\u20131,0 \u0441 (\u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u043e \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f, \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430\u0442\u0438\u0447\u043d\u043e \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a)<\/li>\n\n\n\n<li>\u041d\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u0443\u044e \u0438 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u0443\u044e \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0443<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u044b\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041f\u0438\u043a\u0430\u043f: 1,3\u20131,5\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430<\/li>\n\n\n\n<li>\u0417\u0430\u0434\u0435\u0440\u0436\u043a\u0430: 0,8\u20131,2 \u0441 (\u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-2-harmonic-restraint-preferred-for-automatic-systems\">\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u044f 2: \u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 (\u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0434\u043b\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c)<\/h3>\n\n\n\n<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0440\u0435\u043b\u0435 (SEL-387, ABB REF615, Schneider Sepam) \u043e\u0441\u043d\u0430\u0449\u0435\u043d\u044b \u0444\u0443\u043d\u043a\u0446\u0438\u0435\u0439 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0432\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438. \u041a\u043e\u0433\u0434\u0430 I_2nd \/ I_fundamental &gt; 18%, \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 \u0437\u0430\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u043f\u0435\u0440\u0438\u043e\u0434 \u0432\u0440\u0435\u043c\u0435\u043d\u0438.<\/p>\n\n\n\n<p><strong>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f (SEL-387)<\/strong>:<br><code>87P = 0,25 \u043f\u0443<\/code>\u00a0(\u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0430\u0442\u0447\u0438\u043a, 25% \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430)<br><code>87S = 35%<\/code>\u00a0(\u0443\u043a\u043b\u043e\u043d \u0434\u043b\u044f \u0441\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0441\u043a\u0432\u043e\u0437\u043d\u043e\u0433\u043e \u0440\u0430\u0437\u043b\u043e\u043c\u0430)<br><code>PCT2 = 18%<\/code>\u00a0(\u043f\u043e\u0440\u043e\u0433 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438)<br><code>INHST = 5,0 \u0446\u0438\u043a\u043b\u043e\u0432<\/code>\u00a0(\u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 \u0434\u043e\u043b\u0436\u043d\u044b \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0442\u044c\u0441\u044f &gt;100 \u043c\u0441 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438)<\/p>\n\n\n\n<p><strong>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0420\u0430\u0437\u043b\u0438\u0447\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 (\u0431\u0435\u0437 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u043f\u0440\u0438 \u043d\u0430\u0441\u0442\u043e\u044f\u0449\u0438\u0445 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\u0445)<\/li>\n\n\n\n<li>\u041f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (ATS, \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0422\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a (\u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0440\u0435\u043b\u0435)<\/li>\n\n\n\n<li>\u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 (\u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0441\u0442\u0430\u0440\u044b\u0435 \u0430\u0433\u0440\u0435\u0433\u0430\u0442\u044b) \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0442 &lt;15% \u0432\u0442\u043e\u0440\u0443\u044e \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0443.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445<\/strong>: \u041c\u044b \u0438\u0437\u043c\u0435\u0440\u0438\u043b\u0438 \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 92% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438, \u0438\u043c\u0435\u044e\u0449\u0438\u043c\u0438 \u0442\u043e\u043b\u044c\u043a\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0443\u044e \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443, \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0430\u0445 \u0441 4-6 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0432 \u0434\u0435\u043d\u044c.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-3-controlled-switching-point-on-wave\">\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u044f 3: \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 (Point-on-Wave)<\/h3>\n\n\n\n<p>\u0417\u0430\u043c\u044b\u043a\u0430\u0439\u0442\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043f\u0440\u0438 \u043f\u0438\u043a\u043e\u0432\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438, \u0430 \u043d\u0435 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0438 \u043d\u0443\u043b\u044f. \u041f\u043e\u0442\u043e\u043a \u043d\u0430\u0440\u0430\u0441\u0442\u0430\u0435\u0442 \u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u043e, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f \u2192 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0441\u043d\u0438\u0436\u0430\u0435\u0442\u0441\u044f \u0434\u043e 1-2\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/p>\n\n\n\n<p><strong>\u0420\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u044b \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (ABB Switchsync, Siemens POSA)<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u0438\u0442\u044c \u0444\u0430\u0437\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043e\u0442\u0434\u0430\u0442\u044c \u043a\u043e\u043c\u0430\u043d\u0434\u0443 \u043d\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u0443\u0433\u043b\u0435<\/li>\n\n\n\n<li>\u0422\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0441 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (\u043f\u043e\u0432\u0442\u043e\u0440\u044f\u0435\u043c\u043e\u0441\u0442\u044c \u00b12 \u043c\u0441)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u043d\u0438\u0436\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043d\u0430 85\u201395% \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e \u043e\u0442 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430.<\/li>\n\n\n\n<li>\u0423\u0441\u0442\u0440\u0430\u043d\u044f\u0435\u0442 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0443 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0445<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0412\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c ($5000\u2013$15000 \u0437\u0430 \u043a\u0430\u0436\u0434\u044b\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f)<\/li>\n\n\n\n<li>\u0422\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f VCB \u0441 \u0442\u043e\u0447\u043d\u044b\u043c \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0435\u0439 (\u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0435 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u044b \u0431\u043e\u043b\u0435\u0435 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u044b, \u0447\u0435\u043c \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0435)<\/li>\n\n\n\n<li>\u041d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u0442\u0430\u0440\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041b\u0443\u0447\u0448\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f<\/strong>: \u0411\u043e\u043b\u044c\u0448\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b (&gt;5 \u041c\u0412\u0410), \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0441 \u0447\u0430\u0441\u0442\u044b\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c, \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0438\u0436\u0435 \u043f\u043e \u0446\u0435\u043f\u0438<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-4-pre-insertion-resistors\">\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u044f 4: \u0420\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0432\u0441\u0442\u0430\u0432\u043a\u0438<\/h3>\n\n\n\n<p>\u0412\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u0432\u0441\u0442\u0430\u0432\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u043e\u0434\u0430\u0447\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f, \u0447\u0442\u043e\u0431\u044b \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u0430 \u0437\u0430\u0442\u0435\u043c \u043e\u0431\u043e\u0439\u0434\u0438\u0442\u0435 \u0435\u0433\u043e \u043f\u043e\u0441\u043b\u0435 \u0441\u0442\u0430\u0431\u0438\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u043f\u043e\u0442\u043e\u043a\u0430 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 (50-100 \u043c\u0441).<\/p>\n\n\n\n<p><strong>\u0421\u0445\u0435\u043c\u0430<\/strong>: \u0413\u043b\u0430\u0432\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0441 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u043e\u043c \u2192 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 50-100 \u043c\u0441 \u2192 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u0431\u0430\u0439\u043f\u0430\u0441\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u0435\u0442 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440<\/p>\n\n\n\n<p><strong>\u0420\u0430\u0441\u0447\u0435\u0442 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430<\/strong>:<br>R = V<sub>\u043f\u0438\u043a<\/sub>\u00a0\/ I<sub>\u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u043c\u0430\u043a\u0441.<\/sub><br>\u0414\u043b\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b 12 \u043a\u0412, \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0434\u043e 2\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, 100 \u0410 \u0434\u043b\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 1000 \u043a\u0412\u0410):<br>R = 16 970 \u0412 \/ 100 \u0410 =\u00a0<strong>170 \u041e\u043c<\/strong><br>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c: \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u044f = I\u00b2 \u00d7 R \u00d7 t = (100)\u00b2 \u00d7 170 \u00d7 0,050 =\u00a0<strong>85 \u043a\u0414\u0436<\/strong><\/p>\n\n\n\n<p><strong>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0414\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0441\u043b\u043e\u0436\u043d\u043e\u0441\u0442\u044c (\u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u043e\u0431\u0445\u043e\u0434\u0430, \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c)<\/li>\n\n\n\n<li>\u0420\u0435\u0436\u0438\u043c \u043e\u0442\u043a\u0430\u0437\u0430 \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c \u0446\u0435\u043f\u0438 (\u043d\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435\u043c)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-5-sequential-energization-with-delay\">\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u044f 5: \u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u0434\u0430\u0447\u0430 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439<\/h3>\n\n\n\n<p>\u0412 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445 \u0441 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u043f\u043e\u0434\u0430\u0432\u0430\u0439\u0442\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u043e\u0434\u0438\u043d \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0437\u0430 \u0440\u0430\u0437 \u0441 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u043e\u043c 30\u201360 \u0441\u0435\u043a\u0443\u043d\u0434. \u041f\u0435\u0440\u0432\u044b\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0438\u0441\u043f\u044b\u0442\u044b\u0432\u0430\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a; \u043f\u043e\u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u043b\u0443\u0447\u0430\u044e\u0442 \u043f\u0438\u0442\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u0441\u0442\u0430\u0431\u0438\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u0448\u0438\u043d\u044b.<\/p>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439<\/strong>: \u041d\u0435 \u0432\u043a\u043b\u044e\u0447\u0430\u0439\u0442\u0435 \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u2014 \u0441\u0443\u043c\u043c\u0430\u0440\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043c\u043e\u0436\u0435\u0442 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0442\u044c 1,5-\u043a\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438\u0437-\u0437\u0430 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0439 \u0441\u0432\u044f\u0437\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03.webp\" alt=\"\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043c\u0430\u0442\u0440\u0438\u0446\u0430 \u043f\u044f\u0442\u0438 \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0439 \u0437\u0430\u0449\u0438\u0442\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0445 \u0442\u043e\u043a\u043e\u0432, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0441\u043e\u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438, \u0441\u043b\u043e\u0436\u043d\u043e\u0441\u0442\u0438, \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439\" class=\"wp-image-2412\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 3. \u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0439 \u0437\u0430\u0449\u0438\u0442\u044b: \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0431\u0430\u043b\u0430\u043d\u0441 \u043c\u0435\u0436\u0434\u0443 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c\u044e \u0438 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c\u044e (\u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0430 85\u201395%, \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u0441\u0440\u0435\u0434\u043d\u044f\u044f \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c); \u0442\u043e\u0447\u0435\u0447\u043d\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c, \u043d\u043e \u043f\u0440\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438; \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0441\u0430\u043c\u044b\u043c \u043f\u0440\u043e\u0441\u0442\u044b\u043c \u0441\u043f\u043e\u0441\u043e\u0431\u043e\u043c, \u043d\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sympathetic-inrush-when-energizing-one-transformer-trips-others\">\u0421\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a: \u043a\u043e\u0433\u0434\u0430 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043e\u0434\u043d\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0434\u0440\u0443\u0433\u0438\u0445<\/h2>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u043e\u0434\u0438\u043d \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f, \u0430 \u0434\u0440\u0443\u0433\u0438\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u043e \u043d\u0430 \u0442\u043e\u0439 \u0436\u0435 \u0448\u0438\u043d\u0435, \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u043f\u0440\u043e\u0432\u0430\u043b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0430 \u0448\u0438\u043d\u0435. \u042d\u0442\u043e\u0442 \u043f\u0440\u043e\u0432\u0430\u043b \u0437\u0430\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0443\u0436\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0434\u0430\u0432\u0430\u0442\u044c \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u043f\u043e\u0442\u043e\u043a\u0430, \u0447\u0442\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u201c\u0441\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a\u201d \u0432 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0443\u0436\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u043b\u0438.<\/p>\n\n\n\n<p><strong>\u041c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0441\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/strong>:<br>1. \u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 A \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u2192 \u043f\u043e\u0442\u0440\u0435\u0431\u043b\u044f\u0435\u0442 10-\u043a\u0440\u0430\u0442\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043e\u0442 \u0448\u0438\u043d\u044b<br>2. \u041f\u0430\u0434\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0448\u0438\u043d\u044b 5-15% \u0438\u0437-\u0437\u0430 \u043f\u0430\u0434\u0435\u043d\u0438\u044f \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430<br>3. \u0422\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b B \u0438 C (\u0443\u0436\u0435 \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c) \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u044e\u0442 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0438\u0438.<br>4. \u041e\u0431\u0449\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a = \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 A + \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a (B+C)<br>\u0420\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442: \u0441\u0443\u043c\u043c\u0430\u0440\u043d\u044b\u0439 \u0442\u043e\u043a \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0432\u044b\u0448\u0435 \u043f\u043e \u0446\u0435\u043f\u0438, \u0434\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u0437\u0430\u0449\u0438\u0442\u0430 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0430.<\/p>\n\n\n\n<p><strong>\u0421\u043c\u044f\u0433\u0447\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u0439<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043d\u0430 \u0443\u0440\u043e\u0432\u043d\u0435 \u0448\u0438\u043d\u044b \u043d\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f (\u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u043d\u0430 \u0437\u0430\u0449\u0438\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430).<\/li>\n\n\n\n<li>\u0423\u0432\u0435\u043b\u0438\u0447\u044c\u0442\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0434\u043e 1,5\u20132,0 \u0441.<\/li>\n\n\n\n<li>\u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 30-60 \u0441<\/li>\n<\/ul>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 40 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u0441 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e \u0441\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0434\u043e\u0431\u0430\u0432\u043b\u044f\u043b 20-40% \u043a \u043e\u0431\u0449\u0435\u0439 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u0435 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u0447\u0442\u043e \u0431\u044b\u043b\u043e \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e \u0434\u043b\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0444\u0438\u0434\u0435\u0440\u043e\u0432 \u0441 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u043c\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u0443\u044e\u0449\u0438\u043c\u0438 \u0437\u0430\u043f\u0430\u0441\u0430\u043c\u0438.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"ats-applications-special-considerations\">\u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 ATS: \u043e\u0441\u043e\u0431\u044b\u0435 \u0441\u043e\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<p>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0441\u043e\u0437\u0434\u0430\u044e\u0442 \u0447\u0430\u0441\u0442\u044b\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u2014 \u0435\u0436\u0435\u043d\u0435\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f, \u0435\u0436\u0435\u043c\u0435\u0441\u044f\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f, \u0430 \u0442\u0430\u043a\u0436\u0435 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u041a\u0430\u0436\u0434\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0440\u0438\u0441\u043a \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/p>\n\n\n\n<p><strong>\u041f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u043f\u043e \u043c\u0435\u0440\u0442\u0432\u043e\u043c\u0443 \u0448\u0438\u043d\u0435<\/strong>&nbsp;(\u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u041e\u0442\u043a\u0440\u043e\u0439\u0442\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u043f\u043e\u0434\u043e\u0436\u0434\u0438\u0442\u0435 5-10 \u0441\u0435\u043a\u0443\u043d\u0434 (\u0441\u043f\u0430\u0434 \u043f\u043e\u0442\u043e\u043a\u0430).<\/li>\n\n\n\n<li>\u0417\u0430\u043a\u0440\u043e\u0439\u0442\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u0430 (\u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u2192 \u043d\u0438\u0437\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0422\u0440\u0430\u043d\u0441\u0444\u0435\u0440 \u043d\u0430 \u0430\u0432\u0442\u043e\u0431\u0443\u0441\u0435<\/strong>&nbsp;(\u043d\u0430\u0438\u0445\u0443\u0434\u0448\u0438\u0439 \u0441\u043b\u0443\u0447\u0430\u0439):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u043f\u0435\u0440\u0435\u0434 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c: \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u2192 \u0432\u044b\u0441\u043e\u043a\u0438\u0439 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u2192 \u0441\u0438\u043b\u044c\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a<\/li>\n\n\n\n<li>\u0421\u0434\u0435\u043b\u0430\u0442\u044c \u043f\u0435\u0440\u0435\u0434 \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u043e\u043c: \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u2192 \u0431\u0435\u0437 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u043d\u043e \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u044b\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 ATS<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0417\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u043c\u0435\u0440\u0442\u0432\u043e\u0433\u043e \u0430\u0432\u0442\u043e\u0431\u0443\u0441\u0430: 5-10 \u0441 (\u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0437\u0430\u0442\u0443\u0445\u0430\u0442\u044c \u043f\u043e\u0442\u043e\u043a\u0443)<\/li>\n\n\n\n<li>\u0413\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043e \u043a\u0430\u043a \u043d\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u0445 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u0435\u0442\u0438, \u0442\u0430\u043a \u0438 \u043d\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u0445 \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u0430<\/li>\n\n\n\n<li>\u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u0434\u0430\u0447\u0430 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 (\u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043f\u043e \u043e\u0434\u043d\u043e\u043c\u0443, \u0430 \u043d\u0435 \u043e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e)<\/li>\n<\/ul>\n\n\n\n<p>\u041c\u044b \u0438\u0437\u043c\u0435\u0440\u0438\u043b\u0438 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0447\u0438\u0441\u043b\u0430 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 ATS \u043d\u0430 70% \u043f\u043e\u0441\u043b\u0435 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u044f 10-\u0441\u0435\u043a\u0443\u043d\u0434\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u043f\u0440\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u0448\u0438\u043d\u044b + \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435\u0439 \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u0442\u043e\u043b\u044c\u043a\u043e \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"572\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04.webp\" alt=\"\u0411\u043b\u043e\u043a-\u0441\u0445\u0435\u043c\u0430 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f ATS, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0441 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u0448\u0438\u043d\u044b \u0438 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u044f \u043f\u043e\u0442\u043e\u043a\u0430 \u0434\u043b\u044f \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0430\u0446\u0438\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430.\" class=\"wp-image-2414\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04.webp 572w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04-168x300.webp 168w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04-7x12.webp 7w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 4. \u041f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f ATS \u0441 \u043c\u0435\u0440\u0442\u0432\u043e\u0439 \u0448\u0438\u043d\u043e\u0439 \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u0435\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a: \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u0432 5\u201310 \u0441\u0435\u043a\u0443\u043d\u0434 \u043f\u043e\u0441\u043b\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u043c\u0443 \u043f\u043e\u0442\u043e\u043a\u0443 \u0440\u0430\u0441\u043f\u0430\u0434\u0430\u0442\u044c\u0441\u044f \u043e\u0442 80% \u0434\u043e &lt;30%, \u0441\u043d\u0438\u0436\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u0430 \u0441 10-15\u00d7 \u0434\u043e 3-5\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-troubleshooting-diagnosing-inrush-vs-genuine-faults\">\u0423\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435: \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0445 \u0442\u043e\u043a\u043e\u0432 \u0438 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/h2>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u0443\u044e \u043f\u0440\u0438\u0447\u0438\u043d\u0443 \u043f\u0435\u0440\u0435\u0434 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u043e\u0439 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u043e\u0432:<\/p>\n\n\n\n<p><strong>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/strong>&nbsp;(\u043e\u0431\u044b\u0447\u043d\u0430\u044f \u0444\u0438\u0437\u0438\u043a\u0430):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 100-500 \u043c\u0441 \u043f\u043e\u0441\u043b\u0435 \u043f\u043e\u0434\u0430\u0447\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f<\/li>\n\n\n\n<li>\u0422\u0435\u043a\u0443\u0449\u0430\u044f \u0444\u043e\u0440\u043c\u0430 \u0432\u043e\u043b\u043d\u044b \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u044d\u043a\u0441\u043f\u043e\u043d\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0430\u0434<\/li>\n\n\n\n<li>\u0412\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442 30-70%<\/li>\n\n\n\n<li>\u041f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0447\u0435\u0440\u0435\u0437 30\u201360 \u0441\u0435\u043a\u0443\u043d\u0434 \u043f\u0440\u043e\u0445\u043e\u0434\u0438\u0442 \u0443\u0441\u043f\u0435\u0448\u043d\u043e (\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u0437\u0430\u0442\u0443\u0445)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u043e\u0434\u043b\u0438\u043d\u043d\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0422\u0435\u043a\u0443\u0449\u0438\u0439 \u0442\u043e\u043a \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0441\u044f (\u043d\u0435 \u0437\u0430\u0442\u0443\u0445\u0430\u0435\u0442)<\/li>\n\n\n\n<li>\u0412\u0442\u043e\u0440\u0430\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0430 &lt;5%<\/li>\n\n\n\n<li>\u041d\u0435\u0443\u0434\u0430\u0447\u043d\u043e\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 (\u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u043e-\u043f\u0440\u0435\u0436\u043d\u0435\u043c\u0443 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442)<\/li>\n\n\n\n<li>\u041f\u0440\u0438\u0437\u043d\u0430\u043a\u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f: \u0437\u0430\u043f\u0430\u0445 \u0433\u0430\u0440\u0438, \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f, \u0443\u0442\u0435\u0447\u043a\u0430 \u043c\u0430\u0441\u043b\u0430<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0414\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0414\u0430\u043d\u043d\u044b\u0435 \u0440\u0435\u0433\u0438\u0441\u0442\u0440\u0430\u0442\u043e\u0440\u0430 \u0441\u043e\u0431\u044b\u0442\u0438\u0439 \u0441 \u0437\u0430\u0449\u0438\u0442\u043d\u043e\u0433\u043e \u0440\u0435\u043b\u0435 (\u043f\u0440\u043e\u0441\u043c\u043e\u0442\u0440 \u0444\u043e\u0440\u043c \u0442\u043e\u043a\u0430, \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a)<\/li>\n\n\n\n<li>\u041e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u0444 \u043d\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u0446\u0435\u043f\u0438 \u041a\u0422 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u043f\u0438\u0442\u0430\u043d\u0438\u044f<\/li>\n\n\n\n<li>\u0410\u043d\u0430\u043b\u0438\u0437 \u0440\u0430\u0441\u0442\u0432\u043e\u0440\u0435\u043d\u043d\u043e\u0433\u043e \u0433\u0430\u0437\u0430 (DGA) \u043f\u0440\u0438 \u043f\u043e\u0434\u043e\u0437\u0440\u0435\u043d\u0438\u0438 \u043d\u0430 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u044e\u044e \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c<\/li>\n<\/ul>\n\n\n\n<p><strong>\u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0430 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u041e\u0442\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043e\u0442 \u043f\u0438\u0442\u0430\u043d\u0438\u044f, \u043f\u043e\u0434\u043e\u0436\u0434\u0438\u0442\u0435 10 \u043c\u0438\u043d\u0443\u0442.<\/li>\n\n\n\n<li>\u0412\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u044e \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0430\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u0437\u0430\u043f\u0438\u0441\u044b\u0432\u0430\u044e\u0449\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f<\/li>\n\n\n\n<li>\u0417\u0430\u0445\u0432\u0430\u0442 \u0442\u0435\u043a\u0443\u0449\u0435\u0439 \u0444\u043e\u0440\u043c\u044b \u0441\u0438\u0433\u043d\u0430\u043b\u0430 (0\u20132 \u0441\u0435\u043a\u0443\u043d\u0434\u044b)<\/li>\n\n\n\n<li>\u0410\u043d\u0430\u043b\u0438\u0437: \u044d\u043a\u0441\u043f\u043e\u043d\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0430\u0434 + \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0432\u0442\u043e\u0440\u0430\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0430 = \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a; \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0439 \u0442\u043e\u043a + \u043d\u0438\u0437\u043a\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 = \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\n\n\n\n<p>\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u2014 \u044d\u0442\u043e \u043f\u0440\u0435\u0434\u0441\u043a\u0430\u0437\u0443\u0435\u043c\u043e\u0435 \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u044f\u0432\u043b\u0435\u043d\u0438\u0435, \u0430 \u043d\u0435 \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u0430\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u041d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0435 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u0442\u043e\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0432 8\u201315 \u0440\u0430\u0437 \u0438 \u0437\u0430\u0442\u0443\u0445\u0430\u044e\u0442 \u044d\u043a\u0441\u043f\u043e\u043d\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 0,1\u20130,5 \u0441\u0435\u043a\u0443\u043d\u0434\u044b, \u0447\u0442\u043e \u043e\u0442\u043b\u0438\u0447\u0430\u0435\u0442 \u0438\u0445 \u043e\u0442 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435\u043c \u0432\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 (30\u201370% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 &lt;5% \u0434\u043b\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439). \u041b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u044f\u0442, \u043a\u043e\u0433\u0434\u0430 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u0443\u0435\u0442 \u044d\u0442\u043e \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435, \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u044f \u0432\u0441\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u0442\u043e\u043a\u0438 \u043a\u0430\u043a \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438.<\/p>\n\n\n\n<p>\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u043f\u044f\u0442\u044c \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0439 \u0441\u043c\u044f\u0433\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u0439, \u043a\u0430\u0436\u0434\u0430\u044f \u0438\u0437 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0438\u043c\u0435\u0435\u0442 \u0441\u0432\u043e\u0438 \u043a\u043e\u043c\u043f\u0440\u043e\u043c\u0438\u0441\u0441\u044b \u043c\u0435\u0436\u0434\u0443 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c\u044e \u0438 \u0441\u043b\u043e\u0436\u043d\u043e\u0441\u0442\u044c\u044e: \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0435 \u043f\u043e \u0442\u043e\u043a\u0443 (\u0441\u0430\u043c\u044b\u0439 \u043f\u0440\u043e\u0441\u0442\u043e\u0439 \u0432\u0430\u0440\u0438\u0430\u043d\u0442, \u043d\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u0440\u0435\u043c\u044f \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438), \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a (\u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0432\u0430\u0440\u0438\u0430\u043d\u0442 \u0434\u043b\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c), \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0432 \u0442\u043e\u0447\u043a\u0435 \u0432\u043e\u043b\u043d\u044b (\u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0439, \u043d\u043e \u0434\u043e\u0440\u043e\u0433\u043e\u0439 \u0432\u0430\u0440\u0438\u0430\u043d\u0442), \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u044b \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u0434\u043b\u044f \u043a\u0440\u0430\u0439\u043d\u0438\u0445 \u0441\u043b\u0443\u0447\u0430\u0435\u0432) \u0438 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0438\u0442\u0430\u043d\u0438\u044f (\u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0441 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438). \u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0431\u0430\u043b\u0430\u043d\u0441 \u2014 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u043d\u0430 85\u201395% \u0431\u0435\u0437 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/p>\n\n\n\n<p>\u041a\u043b\u044e\u0447\u0435\u0432\u0430\u044f \u0438\u0434\u0435\u044f: \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0441\u043e\u0431\u043e\u0439 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u0441 \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438 (\u044d\u043a\u0441\u043f\u043e\u043d\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0430\u0434, \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u043e\u0441\u0442\u0430\u0432, \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u044c \u043e\u0442 \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f). \u0421\u0445\u0435\u043c\u044b \u0437\u0430\u0449\u0438\u0442\u044b, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0449\u0438\u0435 \u044d\u0442\u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0438\u0437\u0431\u0438\u0440\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c, \u043d\u0435\u0434\u043e\u0441\u0442\u0438\u0436\u0438\u043c\u0443\u044e \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043f\u0440\u043e\u0441\u0442\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438. \u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0440\u0435\u043b\u0435 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432 \u0441\u0435\u0431\u044f \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0445 \u0444\u0443\u043d\u043a\u0446\u0438\u0439, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0440\u0430\u0437\u043b\u0438\u0447\u0430\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0441 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u0437\u0430\u0442\u0440\u0430\u0442\u0430\u043c\u0438 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0446\u0438\u043a\u043b\u0430\u043c\u0438 \u0437\u0430\u043c\u0435\u043d\u044b \u0440\u0435\u043b\u0435.<\/p>\n\n\n\n<p>\u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043f\u0440\u0435\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438\u0437 \u0445\u0440\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0432 \u0440\u0443\u0442\u0438\u043d\u043d\u0443\u044e \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044e, \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u044f \u043f\u0435\u0440\u0435\u0440\u044b\u0432\u044b \u0432 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435, \u0441\u043d\u0438\u0436\u0430\u044f \u0438\u0437\u043d\u043e\u0441 \u043e\u0442 \u043d\u0435\u043d\u0443\u0436\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u0438 \u043e\u0441\u0432\u043e\u0431\u043e\u0436\u0434\u0430\u044f \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439, \u0430 \u043d\u0435 \u0434\u043b\u044f \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043c\u043d\u0438\u043c\u044b\u0445 \u201c\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u201d, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0438\u043a\u043e\u0433\u0434\u0430 \u043d\u0435 \u0432\u043e\u0441\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u044f\u0442\u0441\u044f \u043f\u0440\u0438 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438.<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u043e\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u043e \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f \u0432 \u044d\u0442\u043e\u043c&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-ratings\/\">\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0430\u043c VCB<\/a>&nbsp;\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043e \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/transformer-cooling-classes-onan-onaf-ofaf-guide\/\">\u0441\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u044b\u0439 \u043a\u043b\u0430\u0441\u0441 \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430<\/a>.<\/p>\n\n\n\n<p><strong>\u0412\u043d\u0435\u0448\u043d\u044f\u044f \u0441\u0441\u044b\u043b\u043a\u0430:<\/strong> \u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u043e\u043c, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0441 \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0440\u0435\u0436\u0438\u043c\u043e\u043c, \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u044b \u0432&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/599\" target=\"_blank\" rel=\"noopener\">\u0421\u0435\u0440\u0438\u044f IEC 60076<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-transformer-inrush--nuisance-trips\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b: \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u0435 \u0442\u043e\u043a\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0438 \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f<\/h2>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 1: \u041f\u043e\u0447\u0435\u043c\u0443 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442 8-15\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u043a\u043e\u0433\u0434\u0430 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0432\u0441\u0435\u0433\u043e 0,5-2%?<\/strong><\/p>\n\n\n\n<p>\u0412 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0432\u0448\u0435\u043c\u0441\u044f \u0440\u0435\u0436\u0438\u043c\u0435 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0432 \u043b\u0438\u043d\u0435\u0439\u043d\u043e\u0439 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u043a\u0440\u0438\u0432\u043e\u0439 B-H, \u0433\u0434\u0435 \u043f\u0440\u043e\u043d\u0438\u0446\u0430\u0435\u043c\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u0432\u044b\u0441\u043e\u043a\u0430. \u041f\u043e\u0434\u0430\u0447\u0430 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0438 \u043d\u0443\u043b\u044f \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u043c \u043f\u043e\u0442\u043e\u043a\u043e\u043c (60-80% \u043e\u0442 \u043f\u0438\u043a\u043e\u0432\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f) \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u043e\u0431\u0449\u0438\u0439 \u0441\u043f\u0440\u043e\u0441 \u043d\u0430 \u043f\u043e\u0442\u043e\u043a 1,8 \u0435.\u0435. \u2014 \u0447\u0442\u043e \u043d\u0430\u043c\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u043f\u043e\u0440\u043e\u0433 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f 1,2-1,3 \u0435.\u0435. \u041f\u0440\u0438 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0438 \u043f\u0440\u043e\u043d\u0438\u0446\u0430\u0435\u043c\u043e\u0441\u0442\u044c \u043f\u0430\u0434\u0430\u0435\u0442, \u0438 \u043d\u0435\u043b\u0438\u043d\u0435\u0439\u043d\u0430\u044f \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u044c B-H \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043a\u0430 \u0434\u043b\u044f \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430. \u041f\u0438\u043a\u043e\u0432\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a = V_\u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u043d\u043e\u0435 \/ (X_\u043d\u0430\u0441\u044b\u0449\u0435\u043d\u043d\u043e\u0435_\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435), \u0433\u0434\u0435 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u043d\u0430\u044f \u0440\u0435\u0430\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0432 10-20 \u0440\u0430\u0437 \u043d\u0438\u0436\u0435 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e\u0439. \u042d\u0442\u043e \u0441\u043e\u0437\u0434\u0430\u0435\u0442 8-15-\u043a\u0440\u0430\u0442\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0439 \u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0430\u0435\u0442\u0441\u044f 100-500 \u043c\u0441, \u043f\u043e\u043a\u0430 \u043f\u043e\u0442\u043e\u043a \u043d\u0435 \u0441\u0442\u0430\u0431\u0438\u043b\u0438\u0437\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u0438 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a \u043d\u0435 \u0432\u044b\u0445\u043e\u0434\u0438\u0442 \u0438\u0437 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0432\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043e\u0442\u043b\u0438\u0447\u0438\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u043e\u0442 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f?<\/strong><\/p>\n\n\n\n<p>\u041f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0441\u043e\u0434\u0435\u0440\u0436\u0438\u0442 \u0432\u0442\u043e\u0440\u0443\u044e \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0443 30-70% (100 \u0413\u0446 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 50 \u0413\u0446), \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u0435 \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u2014 \u0441\u0438\u043b\u044c\u043d\u043e \u043d\u0430\u0441\u044b\u0449\u0430\u044f\u0441\u044c \u043d\u0430 \u043e\u0434\u043d\u043e\u0439 \u043f\u043e\u043b\u043e\u0432\u0438\u043d\u0435 \u0446\u0438\u043a\u043b\u0430 \u0438 \u0440\u0430\u0431\u043e\u0442\u0430\u044f \u043b\u0438\u043d\u0435\u0439\u043d\u043e \u043d\u0430 \u0434\u0440\u0443\u0433\u043e\u0439. \u042d\u0442\u0430 \u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u044f \u0444\u043e\u0440\u043c\u044b \u0432\u043e\u043b\u043d\u044b \u0433\u0435\u043d\u0435\u0440\u0438\u0440\u0443\u0435\u0442 \u0447\u0435\u0442\u043d\u044b\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438. \u041a\u043e\u0440\u043e\u0442\u043a\u0438\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u044f\u0442 \u043f\u043e\u0447\u0442\u0438 \u0441\u0438\u043d\u0443\u0441\u043e\u0438\u0434\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a (&gt;95% \u043e\u0441\u043d\u043e\u0432\u043d\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430, 15-20%, \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043a\u043b\u0430\u0441\u0441\u0438\u0444\u0438\u0446\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u043a\u0430\u043a \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a, \u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u043d\u0430 0,5-1,0 \u0441. \u041d\u0430\u0441\u0442\u043e\u044f\u0449\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0438\u043c\u0435\u044e\u0442 \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u0435 &lt;5%, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0437\u0430\u0449\u0438\u0442\u0430 \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u043e. \u041f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u043d\u0430 85-95% \u043f\u0440\u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0438 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0442\u043e\u043b\u044c\u043a\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041f\u043e\u0447\u0435\u043c\u0443 \u0443 \u043d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0445\u0443\u0436\u0435, \u0447\u0435\u043c \u0443 \u0434\u0440\u0443\u0433\u0438\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441 \u0442\u0430\u043a\u0438\u043c\u0438 \u0436\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438?<\/strong><\/p>\n\n\n\n<p>\u041d\u0430 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0432\u043b\u0438\u044f\u044e\u0442 \u0448\u0435\u0441\u0442\u044c \u0444\u0430\u043a\u0442\u043e\u0440\u043e\u0432: (1) \u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b \u0441\u0435\u0440\u0434\u0435\u0447\u043d\u0438\u043a\u0430 \u2014 \u043a\u0440\u0435\u043c\u043d\u0438\u0435\u0432\u0430\u044f \u0441\u0442\u0430\u043b\u044c CRGO \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0435\u0442 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a 60-80% (\u0445\u0443\u0434\u0448\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a) \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0430\u043c\u043e\u0440\u0444\u043d\u044b\u043c \u043c\u0435\u0442\u0430\u043b\u043b\u043e\u043c 30-50% (\u043b\u0443\u0447\u0448\u0438\u0439); (2) \u0420\u0430\u0437\u043c\u0435\u0440 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u2014 \u0431\u043e\u043b\u0435\u0435 \u043a\u0440\u0443\u043f\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0438\u043c\u0435\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0430 \u0435\u0434\u0438\u043d\u0438\u0446\u0443, \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u044f; (3) \u0418\u043c\u043f\u0435\u0434\u0430\u043d\u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u2014 \u0436\u0435\u0441\u0442\u043a\u0438\u0435 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438 \u0434\u043e\u043f\u0443\u0441\u043a\u0430\u044e\u0442 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043f\u0438\u043a\u0438, \u0441\u043b\u0430\u0431\u044b\u0435 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438 \u043e\u0441\u043b\u0430\u0431\u043b\u044f\u044e\u0442 \u0430\u043c\u043f\u043b\u0438\u0442\u0443\u0434\u0443, \u043d\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u044e\u0442 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c; (4) \u0423\u0433\u043e\u043b \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u2014 \u043f\u0435\u0440\u0435\u0441\u0435\u0447\u0435\u043d\u0438\u0435 \u043d\u0443\u043b\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0434\u0430\u0435\u0442 \u043d\u0430\u0438\u0445\u0443\u0434\u0448\u0438\u0439 \u0441\u043b\u0443\u0447\u0430\u0439 (\u0430\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a), \u043f\u0438\u043a \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0434\u0430\u0435\u0442 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a; (5) \u0418\u0441\u0442\u043e\u0440\u0438\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u2014 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0431\u044b\u043b\u0438 \u0441\u0438\u043b\u044c\u043d\u043e \u043d\u0430\u0433\u0440\u0443\u0436\u0435\u043d\u044b \u043f\u0435\u0440\u0435\u0434 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044e\u0442 \u0431\u043e\u043b\u044c\u0448\u0435 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430; (6) \u041f\u0440\u0435\u0434\u044b\u0434\u0443\u0449\u0435\u0435 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0435 \u2014 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0435 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u043d\u0443\u043b\u0435\u0432\u043e\u043c \u0442\u043e\u043a\u0435 \u043c\u0430\u043a\u0441\u0438\u043c\u0438\u0437\u0438\u0440\u0443\u0435\u0442 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a (80%), \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u043e\u0435 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u043e\u0442 30 \u0434\u043e 80%.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 4: \u041a\u0430\u043a\u0438\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0442 \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u0438 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u043c \u0442\u043e\u043a\u0435 \u0431\u0435\u0437 \u0443\u0449\u0435\u0440\u0431\u0430 \u0434\u043b\u044f \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439?<\/strong><\/p>\n\n\n\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 (\u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e): \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u0432\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 \u043f\u0440\u0438 \u043f\u043e\u0440\u043e\u0433\u0435 15-18% (PCT2 = 18% \u043d\u0430 \u0440\u0435\u043b\u0435 SEL, \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 50H \u043d\u0430 ABB). \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 0,25 pu (87P = 0,25), \u043d\u0430\u043a\u043b\u043e\u043d \u043d\u0430 35% (87S = 35%). \u042d\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u0442\u044c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 (&lt;100 \u043c\u0441 \u0434\u043b\u044f \u043f\u043e\u0434\u043b\u0438\u043d\u043d\u044b\u0445 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439) \u043f\u0440\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u0415\u0441\u043b\u0438 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043d\u0435\u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 0,8-1,2 \u0441 \u0441 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435\u043c \u043f\u0440\u0438 1,3-1,5\u00d7 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u2014 \u044d\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0437\u0430 \u0441\u0447\u0435\u0442 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0438\u043c\u043c\u0443\u043d\u0438\u0442\u0435\u0442 \u043a \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0442\u043e\u043a\u0430\u043c. \u0414\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441 \u0447\u0430\u0441\u0442\u044b\u043c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c (ATS, \u043f\u0435\u0440\u0435\u043d\u043e\u0441 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438) \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c; \u0442\u043e\u043b\u044c\u043a\u043e \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043d\u0435\u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u0443\u044e \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u043c \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u0430 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 5: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0441 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u043f\u043e \u0442\u043e\u0447\u043a\u0435 \u043d\u0430 \u0432\u043e\u043b\u043d\u0435, \u0447\u0442\u043e\u0431\u044b \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u0443\u0441\u0442\u0440\u0430\u043d\u0438\u0442\u044c \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a?<\/strong><\/p>\n\n\n\n<p>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u044b Point-on-wave \u0441\u043d\u0438\u0436\u0430\u044e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u043d\u0430 85-95%, \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043f\u0440\u0438 \u043f\u0438\u043a\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (\u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u043e\u0435 \u043d\u0430\u0440\u0430\u0441\u0442\u0430\u043d\u0438\u0435 \u043f\u043e\u0442\u043e\u043a\u0430, \u0431\u0435\u0437 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f). \u041e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0441\u044f \u043d\u0435\u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u043d\u044b\u0439 \u043f\u043e\u0442\u043e\u043a \u043d\u0430\u0447\u0438\u043d\u0430\u0435\u0442\u0441\u044f \u0441 \u043d\u0443\u043b\u044f \u0438 \u043d\u0430\u0440\u0430\u0441\u0442\u0430\u0435\u0442 \u0441\u0438\u043c\u043c\u0435\u0442\u0440\u0438\u0447\u043d\u043e \u0434\u043e \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u00b11,0 \u0435\u0434., \u0447\u0442\u043e \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u043d\u0438\u0436\u0435 \u043f\u043e\u0440\u043e\u0433\u0430 \u043d\u0430\u0441\u044b\u0449\u0435\u043d\u0438\u044f 1,2 \u0435\u0434. \u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f: (1) VCB \u0441 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (\u043f\u043e\u0432\u0442\u043e\u0440\u044f\u0435\u043c\u043e\u0441\u0442\u044c \u00b12 \u043c\u0441, \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0435 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u044b \u043b\u0443\u0447\u0448\u0435 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0445); (2) \u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440, \u0438\u0437\u043c\u0435\u0440\u044f\u044e\u0449\u0438\u0439 \u0444\u0430\u0437\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f; (3) \u0421\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c $5000-$15000 \u0437\u0430 \u043a\u0430\u0436\u0434\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c. \u041d\u0430\u0438\u043b\u0443\u0447\u0448\u0438\u0439 \u0432\u0430\u0440\u0438\u0430\u043d\u0442 \u0434\u043b\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 (&gt;5 \u041c\u0412\u0410), \u0447\u0430\u0441\u0442\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u0435\u0436\u0435\u0434\u043d\u0435\u0432\u043d\u044b\u0435 \u0446\u0438\u043a\u043b\u044b) \u0438\u043b\u0438 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a, \u043d\u0435\u043f\u0435\u0440\u0435\u043d\u043e\u0441\u0438\u043c\u044b\u0445 \u043a \u043f\u0430\u0434\u0435\u043d\u0438\u044e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043e\u0442 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u041d\u0435\u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u0435\u043d \u0441 \u0442\u043e\u0447\u043a\u0438 \u0437\u0440\u0435\u043d\u0438\u044f \u0437\u0430\u0442\u0440\u0430\u0442 \u0434\u043b\u044f \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441 \u0440\u0435\u0434\u043a\u0438\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c \u2014 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u043e 90%+ \u043f\u0440\u0438 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 &lt;10%.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 6: \u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0441\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u0441\u043f\u043b\u0435\u0441\u043a \u0442\u043e\u043a\u0430 \u0438 \u043a\u043e\u0433\u0434\u0430 \u043e\u043d \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b?<\/strong><\/p>\n\n\n\n<p>\u0421\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u0435\u0442, \u043a\u043e\u0433\u0434\u0430 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043e\u0434\u043d\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f \u0432 \u0443\u0436\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u044b\u0445 \u043f\u0430\u0440\u0430\u043b\u043b\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u0445. \u041c\u0435\u0445\u0430\u043d\u0438\u0437\u043c: \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 A \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u2192 10-\u043a\u0440\u0430\u0442\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u2192 \u043f\u0430\u0434\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0430 \u0448\u0438\u043d\u0435 5-15% \u0438\u0437-\u0437\u0430 \u0438\u043c\u043f\u0435\u0434\u0430\u043d\u0441\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u2192 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b B \u0438 C (\u0443\u0436\u0435 \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0438\u0435) \u0434\u043e\u043b\u0436\u043d\u044b \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0442\u044c \u0442\u043e\u043a \u043d\u0430\u043c\u0430\u0433\u043d\u0438\u0447\u0438\u0432\u0430\u043d\u0438\u044f, \u0447\u0442\u043e\u0431\u044b \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043f\u0430\u0434\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u043f\u043e\u0442\u043e\u043a. \u041e\u0431\u0449\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0448\u0438\u043d\u044b = \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a (A) + \u0441\u0438\u043c\u043f\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a (B+C), \u0447\u0430\u0441\u0442\u043e \u0432 1,2-1,5 \u0440\u0430\u0437\u0430 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0439 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u043e\u043a \u0442\u043e\u043b\u044c\u043a\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430 A. \u042d\u0442\u043e \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u0432\u044b\u0448\u0435 \u043f\u043e \u0446\u0435\u043f\u0438, \u0434\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u0437\u0430\u0449\u0438\u0442\u0430 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0441\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0430. \u0421\u043c\u044f\u0433\u0447\u0435\u043d\u0438\u0435: \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u0435\u043b\u044c \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a \u043d\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435 \u0444\u0438\u0434\u0435\u0440\u0430, \u0443\u0432\u0435\u043b\u0438\u0447\u044c\u0442\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443 \u0434\u043e 1,5-2,0 \u0441 \u0438\u043b\u0438 \u0432\u043a\u043b\u044e\u0447\u0430\u0439\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 30-60 \u0441.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 7: \u041a\u0430\u043a \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c, \u0431\u044b\u043b\u043e \u043b\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0432\u044b\u0437\u0432\u0430\u043d\u043e \u043f\u0443\u0441\u043a\u043e\u0432\u044b\u043c \u0442\u043e\u043a\u043e\u043c \u0438\u043b\u0438 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0439 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c\u044e \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430?<\/strong><\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0437\u0430\u043f\u0438\u0441\u0438 \u0441\u043e\u0431\u044b\u0442\u0438\u0439 \u0437\u0430\u0449\u0438\u0442\u043d\u043e\u0433\u043e \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u0442\u0435\u043a\u0443\u0449\u0435\u0439 \u0444\u043e\u0440\u043c\u044b \u0432\u043e\u043b\u043d\u044b \u0438 \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a:&nbsp;<strong>\u0421\u0438\u0433\u043d\u0430\u0442\u0443\u0440\u0430 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/strong>&nbsp;\u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u044d\u043a\u0441\u043f\u043e\u043d\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0430\u0434 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 100-500 \u043c\u0441, \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435 \u0432\u0442\u043e\u0440\u043e\u0439 \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u043a\u0438 30-701 \u0422\u041f3\u0422, \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043f\u0435\u0440\u0432\u044b\u0445 500 \u043c\u0441 \u043f\u043e\u0441\u043b\u0435 \u043f\u043e\u0434\u0430\u0447\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f, \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u043b\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 30-60 \u0441 (\u0441\u043f\u0430\u0434 \u043f\u043e\u0442\u043e\u043a\u0430).&nbsp;<strong>\u0421\u0438\u0433\u043d\u0430\u0442\u0443\u0440\u0430 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438<\/strong>&nbsp;\u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0439 \u0442\u043e\u043a (\u0431\u0435\u0437 \u0437\u0430\u0442\u0443\u0445\u0430\u043d\u0438\u044f), 1000 \u041c\u041e\u043c \u0432 \u043d\u043e\u0440\u043c\u0435), \u0430\u043d\u0430\u043b\u0438\u0437 \u0440\u0430\u0441\u0442\u0432\u043e\u0440\u0435\u043d\u043d\u044b\u0445 \u0433\u0430\u0437\u043e\u0432 (DGA) \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0438 \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440 \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439.<\/p>","protected":false},"excerpt":{"rendered":"<p>Transformer energization creates the most common nuisance trip condition in medium-voltage distribution systems. The magnetic core must establish flux when voltage is applied, and if switching occurs near voltage zero-crossing, the flux waveform becomes asymmetric\u2014driving the core into deep saturation. Magnetizing current skyrockets from its normal 0.5-2% of rated load to 8-15\u00d7 transformer full-load current, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2411,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-2409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2409"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2409\/revisions"}],"predecessor-version":[{"id":3562,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2409\/revisions\/3562"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2411"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}