{"id":2425,"date":"2026-01-04T05:56:04","date_gmt":"2026-01-04T05:56:04","guid":{"rendered":"https:\/\/xbrele.com\/?p=2425"},"modified":"2026-04-07T13:47:11","modified_gmt":"2026-04-07T13:47:11","slug":"vcb-timing-test-travel-curves-interruption-reliability","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/vcb-timing-test-travel-curves-interruption-reliability\/","title":{"rendered":"\u0422\u0435\u0441\u0442 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 VCB \u0438 \u043a\u0440\u0438\u0432\u044b\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u0430: \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0438"},"content":{"rendered":"<p>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f (VCB) \u0438\u0437\u043c\u0435\u0440\u044f\u044e\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0440\u0435\u0430\u043a\u0446\u0438\u044e \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u2014 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u043f\u043b\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f \u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f. \u042d\u0442\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442, \u0447\u0442\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043e \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439, \u0447\u0442\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438\u0437\u043d\u043e\u0441 \u043d\u0435 \u0443\u0445\u0443\u0434\u0448\u0438\u043b \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0438 \u0447\u0442\u043e \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u0435\u0440\u043d\u044b\u043c\u0438. VCB \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f 40 \u043c\u0441, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u043f\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e \u0443\u0445\u0443\u0434\u0448\u0430\u0435\u0442\u0441\u044f \u0434\u043e 60 \u043c\u0441, \u043c\u043e\u0436\u0435\u0442 \u043d\u0435 \u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c\u0441\u044f \u0441 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435\u043c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0434\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u0442 \u043a \u043e\u0448\u0438\u0431\u043a\u0430\u043c \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438. \u0410\u043d\u0430\u043b\u0438\u0437 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442, \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u043b\u0438 \u0443\u0441\u043a\u043e\u0440\u044f\u044e\u0442\u0441\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u0438\u0441\u043f\u0440\u0430\u0432\u043d\u044b \u043b\u0438 \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u044b \u0438 \u043a\u043e\u0433\u0434\u0430 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0441\u043c\u0430\u0437\u0430\u0442\u044c \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043f\u0440\u0443\u0436\u0438\u043d\u044b, \u0447\u0442\u043e\u0431\u044b \u043d\u0435 \u043f\u0440\u043e\u0438\u0437\u043e\u0448\u043b\u0430 \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u043e\u043b\u043e\u043c\u043a\u0430.<\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 \u043f\u0440\u043e\u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0438\u043b\u0438 \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f: \u0432\u044b \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0435 \u0442\u0435\u0441\u0442\u043e\u0432\u044b\u0439 \u043d\u0430\u0431\u043e\u0440 \u0434\u043b\u044f \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u0437\u0430\u043f\u0443\u0441\u043a\u0430\u0435\u0442\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435, \u0438 \u043e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u0444 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0447\u0435\u0440\u0435\u0437 50 \u043c\u0441 \u0432\u043c\u0435\u0441\u0442\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 35 \u043c\u0441. \u042f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043b\u0438 \u044d\u0442\u043e \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u043c \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435\u043c \u0438\u043b\u0438 \u043f\u0440\u0438\u0437\u043d\u0430\u043a\u043e\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0437\u043d\u043e\u0441\u0430? \u0412\u043b\u0438\u044f\u0435\u0442 \u043b\u0438 \u044d\u0442\u043e \u043d\u0430 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f \u0434\u0443\u0433\u0438? \u0421\u043b\u0435\u0434\u0443\u0435\u0442 \u043b\u0438 \u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438\u043b\u0438 \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e \u043f\u0440\u043e\u0432\u0435\u0441\u0442\u0438 \u0435\u0433\u043e \u043a\u0430\u043f\u0438\u0442\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0435\u043c\u043e\u043d\u0442? \u0411\u0435\u0437 \u043f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u044f <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"noopener\">\u041c\u042d\u041a 62271-100<\/a> \u0434\u043e\u043f\u0443\u0441\u043a\u0438 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0438 \u0432\u0437\u0430\u0438\u043c\u043e\u0441\u0432\u044f\u0437\u044c \u043c\u0435\u0436\u0434\u0443 \u043a\u0440\u0438\u0432\u044b\u043c\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u0438 \u0444\u0438\u0437\u0438\u043a\u043e\u0439 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f, \u0432\u044b \u043d\u0435 \u043c\u043e\u0436\u0435\u0442\u0435 \u043f\u0440\u0438\u043d\u044f\u0442\u044c \u044d\u0442\u043e \u0440\u0435\u0448\u0435\u043d\u0438\u0435, \u0440\u0438\u0441\u043a\u0443\u044f \u043b\u0438\u0431\u043e \u043d\u0435\u043d\u0443\u0436\u043d\u044b\u043c \u043f\u0440\u043e\u0441\u0442\u043e\u044f\u043c\u0438 (\u0443\u0434\u0430\u043b\u0435\u043d\u0438\u0435 \u0438\u0441\u043f\u0440\u0430\u0432\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439), \u043b\u0438\u0431\u043e \u0441\u0431\u043e\u044f\u043c\u0438 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 (\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u0432 \u0441\u0435\u0442\u0438).<\/p>\n\n\n\n<p>\u0412 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u043e\u0431\u044a\u044f\u0441\u043d\u044f\u044e\u0442\u0441\u044f \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 VCB, \u0438\u043d\u0442\u0435\u0440\u043f\u0440\u0435\u0442\u0430\u0446\u0438\u044f \u043a\u0440\u0438\u0432\u043e\u0439 \u0445\u043e\u0434\u0430 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c\u0438 IEC, \u043c\u0435\u0442\u043e\u0434\u044b \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u043d\u0430 \u043c\u0435\u0441\u0442\u0435 \u0432 \u0441\u043b\u0443\u0447\u0430\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0439 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438, \u0430 \u0442\u0430\u043a\u0436\u0435 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0432\u0437\u0430\u0438\u043c\u043e\u0441\u0432\u044f\u0437\u044c \u043c\u0435\u0436\u0434\u0443 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0435\u0439 \u0438 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c\u044e \u043a \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044e.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 VCB \u0438 \u043a\u0440\u0438\u0432\u044b\u0435 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f: \u043f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/9AU5AGaDwtY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-opening-time-affects-interruption-capability\">\u041f\u043e\u0447\u0435\u043c\u0443 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0432\u043b\u0438\u044f\u0435\u0442 \u043d\u0430 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u044c \u0440\u0430\u0431\u043e\u0442\u0443<\/h2>\n\n\n\n<p>\u0412 \u0441\u043b\u0443\u0447\u0430\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 VCB \u0434\u043e\u043b\u0436\u0435\u043d \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438 \u043f\u043e\u0433\u0430\u0441\u0438\u0442\u044c \u0434\u0443\u0433\u0443 \u0434\u043e \u0442\u043e\u0433\u043e, \u043a\u0430\u043a: (1) \u044d\u043d\u0435\u0440\u0433\u0438\u044f \u0434\u0443\u0433\u0438 \u043f\u043e\u0432\u0440\u0435\u0434\u0438\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0438\u043b\u0438 (2) \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u0442 \u043a \u0440\u0430\u0437\u0440\u0443\u0448\u0435\u043d\u0438\u044e \u043a\u0435\u0440\u0430\u043c\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0437\u043e\u043b\u044f\u0442\u043e\u0440\u0430. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f (\u043e\u0431\u044b\u0447\u043d\u043e 30\u201350 \u043c\u0441), \u0447\u0442\u043e\u0431\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u043d\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u044d\u0442\u0438\u0445 \u043f\u0440\u0435\u0434\u0435\u043b\u043e\u0432 \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<p><strong>\u041a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f<\/strong>:<br>t<sub>\u043e\u0442\u043a\u0440\u044b\u0442\u044b\u0439<\/sub>\u00a0= t<sub>\u0432\u044b\u043f\u0443\u0441\u043a<\/sub>\u00a0+ t<sub>\u043a\u043e\u043d\u0442\u0430\u043a\u0442<\/sub>\u00a0+ t<sub>\u0434\u0443\u0433\u0430<\/sub><br><br>\u2022\u00a0<strong>t<sub>\u0432\u044b\u043f\u0443\u0441\u043a<\/sub><\/strong>: \u041a\u0430\u0442\u0443\u0448\u043a\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u0442 \u2192 \u0437\u0430\u0449\u0435\u043b\u043a\u0430 \u043e\u0442\u043f\u0443\u0441\u043a\u0430\u0435\u0442\u0441\u044f (5\u201315 \u043c\u0441)<br>\u2022\u00a0<strong>t<sub>\u043a\u043e\u043d\u0442\u0430\u043a\u0442<\/sub><\/strong>: \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0430\u0447\u0438\u043d\u0430\u044e\u0442 \u0434\u0432\u0438\u0433\u0430\u0442\u044c\u0441\u044f \u2192 \u043f\u043e\u043b\u043d\u043e\u0435 \u043e\u0442\u0434\u0435\u043b\u0435\u043d\u0438\u0435 (15-30 \u043c\u0441)<br>\u2022\u00a0<strong>t<sub>\u0434\u0443\u0433\u0430<\/sub><\/strong>: \u0418\u043d\u0438\u0446\u0438\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438 \u2192 \u043f\u0435\u0440\u0435\u0445\u043e\u0434 \u0442\u043e\u043a\u0430 \u0447\u0435\u0440\u0435\u0437 \u043d\u0443\u043b\u044c + \u043f\u043e\u0433\u0430\u0441\u0430\u043d\u0438\u0435 \u0434\u0443\u0433\u0438 (5\u201310 \u043c\u0441)<br>\u0412\u0441\u0435\u0433\u043e: 25\u201355 \u043c\u0441 \u0434\u043b\u044f \u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 12 \u043a\u0412<\/p>\n\n\n\n<p><strong>\u041d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u0438\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438<\/strong>: \u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c 25 \u043a\u0410 \u043f\u0440\u0438 12 \u043a\u0412 \u0434\u0430\u0435\u0442 ~50 \u043a\u0412\u0442 \u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442. \u0415\u0441\u043b\u0438 \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0441 35 \u043c\u0441 \u0434\u043e 50 \u043c\u0441, \u044d\u043d\u0435\u0440\u0433\u0438\u044f \u0434\u0443\u0433\u0438 \u0432\u043e\u0437\u0440\u0430\u0441\u0442\u0430\u0435\u0442 \u0441 1,75 \u043a\u0414\u0436 \u0434\u043e 2,5 \u043a\u0414\u0436 (+43%), \u0447\u0442\u043e \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0432\u044b\u0441\u0438\u0442\u044c \u043f\u0440\u0435\u0434\u0435\u043b\u044b \u044d\u0440\u043e\u0437\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u043c\u0443 \u0432\u044b\u0445\u043e\u0434\u0443 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f.<\/p>\n\n\n\n<p><strong>\u0414\u043e\u043f\u0443\u0441\u043a \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-100<\/strong>: \u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u2264 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 + 10%. \u0414\u043b\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c 40 \u043c\u0441 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e 44 \u043c\u0441; 48 \u043c\u0441 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430.<\/p>\n\n\n\n<p>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/what-is-vacuum-circuit-breaker-working-principle\/\">\u043a\u0430\u043a \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438<\/a>&nbsp;\u043e\u0431\u044a\u044f\u0441\u043d\u044f\u0435\u0442, \u043f\u043e\u0447\u0435\u043c\u0443 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u0432\u043b\u0438\u044f\u0435\u0442 \u043d\u0430 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01.webp\" alt=\"\u0412\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0434\u0438\u0430\u0433\u0440\u0430\u043c\u043c\u0430, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f VCB, \u0442\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u043e\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435, \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u0433\u0430\u0448\u0435\u043d\u0438\u0435 \u0434\u0443\u0433\u0438 \u0441 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u0430\u043c\u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u0438\" class=\"wp-image-2428\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 1. \u0412\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0448\u043a\u0430\u043b\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f VCB: \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0440\u0430\u0441\u0446\u0435\u043f\u0438\u0442\u0435\u043b\u044f (5\u201315 \u043c\u0441), \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (15\u201330 \u043c\u0441) \u0438 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0434\u0443\u0433\u0438 (5\u201310 \u043c\u0441) \u0432 \u043e\u0431\u0449\u0435\u0439 \u0441\u043b\u043e\u0436\u043d\u043e\u0441\u0442\u0438 25\u201355 \u043c\u0441. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u2264 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 +10% \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438 \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact-travel-curve-anatomy-interpreting-position-vs-time\">\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0410\u043d\u0430\u0442\u043e\u043c\u0438\u044f \u043a\u0440\u0438\u0432\u043e\u0439 \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f: \u0438\u043d\u0442\u0435\u0440\u043f\u0440\u0435\u0442\u0430\u0446\u0438\u044f \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043f\u043e \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u044e \u043a\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438<\/h2>\n\n\n\n<p>\u041a\u0440\u0438\u0432\u0430\u044f \u0445\u043e\u0434\u0430 \u043e\u0442\u043e\u0431\u0440\u0430\u0436\u0430\u0435\u0442 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 (\u0432\u0435\u0440\u0442\u0438\u043a\u0430\u043b\u044c\u043d\u0430\u044f \u043e\u0441\u044c, \u043c\u043c) \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 (\u0433\u043e\u0440\u0438\u0437\u043e\u043d\u0442\u0430\u043b\u044c\u043d\u0430\u044f \u043e\u0441\u044c, \u043c\u0441) \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0438\u043b\u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f. \u0424\u043e\u0440\u043c\u0430 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435: \u043f\u043b\u0430\u0432\u043d\u043e\u0435 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0443\u044e \u0441\u0438\u043b\u0443 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438 \u0441\u043c\u0430\u0437\u043a\u0443; \u0440\u0435\u0437\u043a\u0438\u0435 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u0437\u0430\u043a\u043b\u0438\u043d\u0438\u0432\u0430\u043d\u0438\u0435, \u0438\u0437\u043d\u043e\u0441 \u0438\u043b\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430.<\/p>\n\n\n\n<p><strong>\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043a\u0440\u0438\u0432\u043e\u0439<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430<\/strong>: \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u043d\u0435\u043f\u043e\u0434\u0432\u0438\u0436\u043d\u044b\u043c\u0438, \u043f\u043e\u043a\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430\u0445\u043e\u0434\u0438\u0442\u0441\u044f \u043f\u043e\u0434 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0438 \u0437\u0430\u0449\u0435\u043b\u043a\u0430 \u043e\u0442\u043f\u0443\u0441\u043a\u0430\u0435\u0442\u0441\u044f (0\u201310 \u043c\u0441)<\/li>\n\n\n\n<li><strong>\u0424\u0430\u0437\u0430 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u044f<\/strong>: \u041e\u0442\u043a\u0440\u044b\u0442\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0440\u0430\u0437\u0434\u0432\u0438\u0433\u0430\u0435\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f (10-20 \u043c\u0441)<\/li>\n\n\n\n<li><strong>\u041f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c<\/strong>: \u0414\u043e\u0441\u0442\u0438\u0433\u043d\u0443\u0442\u0430 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c, \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440 \u0435\u0449\u0435 \u043d\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d (20-30 \u043c\u0441)<\/li>\n\n\n\n<li><strong>\u0417\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u0435<\/strong>: \u0410\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440 \u043f\u043e\u0433\u043b\u043e\u0449\u0430\u0435\u0442 \u044d\u043d\u0435\u0440\u0433\u0438\u044e, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0434\u0430\u0440 \u0432 \u043a\u043e\u043d\u0446\u0435 \u0445\u043e\u0434\u0430 (30-40 \u043c\u0441)<\/li>\n\n\n\n<li><strong>\u041e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u0437\u0438\u0446\u0438\u044f<\/strong>: \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u043e\u0442\u043a\u0440\u044b\u0442\u044b, \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440 \u0441\u0436\u0430\u0442, \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u0435 \u043e\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442\u0441\u044f (40\u201345 \u043c\u0441)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f VCB 12 \u043a\u0412<\/strong>:<br>\u2022\u00a0<strong>\u041e\u0431\u0449\u0438\u0439 \u0445\u043e\u0434<\/strong>: 10\u201314 \u043c\u043c (\u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c\u0438)<br>\u2022\u00a0<strong>\u041f\u0438\u043a\u043e\u0432\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c<\/strong>: 0,8\u20131,2 \u043c\/\u0441 (\u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442\u0441\u044f \u043f\u0440\u0438 \u0445\u043e\u0434\u0435 60\u201370%)<br>\u2022\u00a0<strong>\u0421\u0440\u0435\u0434\u043d\u044f\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c<\/strong>: 0,5\u20130,7 \u043c\/\u0441 (\u0432\u0440\u0435\u043c\u044f \u0445\u043e\u0434\u0430\/\u0432\u0440\u0435\u043c\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430)<br>\u2022\u00a0<strong>\u0421\u0446\u0435\u043f\u043b\u0435\u043d\u0438\u0435 \u0441 \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u043e\u043c<\/strong>: \u041f\u043e\u0441\u043b\u0435\u0434\u043d\u0438\u0435 20-30% \u0445\u043e\u0434\u0430<br>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043d\u0435 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0442\u043e\u0447\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u2014 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u0438\u0445 \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044e \u0434\u0443\u0433\u0438.<\/p>\n\n\n\n<p><strong>\u041e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u044f \u043a\u0440\u0438\u0432\u043e\u0439, \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0435 \u043d\u0430 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435<\/strong>: \u0421\u043b\u0430\u0431\u0430\u044f \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0430\u044f\u0441\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u0430 (\u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0437\u0430\u043c\u0435\u043d\u0430)<\/li>\n\n\n\n<li><strong>\u0421\u043a\u0430\u0447\u043a\u0438 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438<\/strong>: \u0417\u0430\u043a\u043b\u0438\u043d\u0438\u0432\u0430\u043d\u0438\u0435 \u0432 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0438 (\u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 \u0441\u043e \u0441\u043c\u0430\u0437\u043a\u043e\u0439 \u0438\u043b\u0438 \u0432\u044b\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u043d\u0438\u0435\u043c)<\/li>\n\n\n\n<li><strong>\u0411\u0435\u0437 \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u044f \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430<\/strong>: \u0423\u0442\u0435\u0447\u043a\u0430 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0438\u0437 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430, \u0440\u0438\u0441\u043a \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0442 \u0443\u0434\u0430\u0440\u0430<\/li>\n\n\n\n<li><strong>\u0423\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u043d\u044b\u0439 \u0445\u043e\u0434<\/strong>: \u041a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0435 \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u044e\u0442 \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u0433\u043e \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f (\u043d\u0435\u0443\u0434\u043e\u0432\u043b\u0435\u0442\u0432\u043e\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0434\u0430\u043c\u0438)<\/li>\n<\/ul>\n\n\n\n<p>\u041f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f 120 VCB, \u0432\u043e\u0437\u0440\u0430\u0441\u0442 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u043b 10\u201320 \u043b\u0435\u0442, \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438, \u0447\u0442\u043e 25% \u0438\u043c\u0435\u043b \u0438\u0437\u043d\u043e\u0441 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 (\u0431\u0435\u0437 \u0432\u0438\u0434\u0438\u043c\u043e\u0433\u043e \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u044f), 15% \u0438\u043c\u0435\u043b \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u043d\u044b\u0439 \u0445\u043e\u0434 (&lt;90% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e), \u0430 8% \u0438\u043c\u0435\u043b \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0443, \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0443\u044e \u0434\u043e\u043f\u0443\u0441\u043a IEC +10%.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02.webp\" alt=\"\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0433\u0440\u0430\u0444\u0438\u043a, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u0443\u044e \u043a\u0440\u0438\u0432\u0443\u044e \u0445\u043e\u0434\u0430 VCB \u0432 \u0432\u0438\u0434\u0435 \u043f\u043b\u0430\u0432\u043d\u043e\u0439 S-\u043e\u0431\u0440\u0430\u0437\u043d\u043e\u0439 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u043d\u043e\u0439 \u043a\u0440\u0438\u0432\u043e\u0439 \u0441 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u044b\u043c \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435\u043c \u0431\u0435\u0437 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u0438 \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u043d\u044b\u043c \u0445\u043e\u0434\u043e\u043c.\" class=\"wp-image-2430\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 2. \u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u043a\u0440\u0438\u0432\u044b\u0445 \u0445\u043e\u0434\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430: \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043a\u0440\u0438\u0432\u0430\u044f (\u0441\u043b\u0435\u0432\u0430) \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043f\u043b\u0430\u0432\u043d\u043e\u0435 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435 \u0434\u043e \u043f\u0438\u043a\u043e\u0432\u043e\u0439 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 1,0 \u043c\/\u0441 \u0441 \u0432\u0438\u0434\u0438\u043c\u044b\u043c \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u0435\u043c \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430; \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u043d\u0430\u044f \u043a\u0440\u0438\u0432\u0430\u044f (\u0441\u043f\u0440\u0430\u0432\u0430) \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u0435\u0442 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435 (\u0441\u043b\u0430\u0431\u0430\u044f \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0430\u044f\u0441\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u0430), \u0441\u043a\u0430\u0447\u043a\u0438 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 (\u0437\u0430\u043a\u043b\u0438\u043d\u0438\u0432\u0430\u043d\u0438\u0435 \u0441\u0432\u044f\u0437\u0438), \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u044f (\u0443\u0442\u0435\u0447\u043a\u0430 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0438\u0437 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430) \u0438 \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u043d\u044b\u0439 \u043a\u043e\u043d\u0435\u0447\u043d\u044b\u0439 \u0445\u043e\u0434 (&lt;90% \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c).<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-test-procedure-equipment-and-measurement\">\u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0430 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439: \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<p>\u0414\u043b\u044f \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0435\u0435 \u043f\u043e\u0434\u0430\u0432\u0430\u0442\u044c \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0439 \u0442\u043e\u043a \u043d\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f\/\u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u0438\u0437\u043c\u0435\u0440\u044f\u0442\u044c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u0438\u043b\u0438 \u043b\u0438\u043d\u0435\u0439\u043d\u044b\u0445 \u0434\u0430\u0442\u0447\u0438\u043a\u043e\u0432 \u0438 \u0440\u0435\u0433\u0438\u0441\u0442\u0440\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u0441 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435\u043c \u0432 \u043c\u0438\u043a\u0440\u043e\u0441\u0435\u043a\u0443\u043d\u0434\u044b.<\/p>\n\n\n\n<p><strong>\u0418\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0410\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440 VCB<\/strong>\u00a0(Omicron CB-1, Megger EZCT-2000, Doble TDR-500): \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0441 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u043c \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043e\u043c \u0434\u0430\u0442\u0447\u0438\u043a\u0430 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f<\/li>\n\n\n\n<li><strong>\u0414\u0430\u0442\u0447\u0438\u043a \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f<\/strong>: \u041b\u0438\u043d\u0435\u0439\u043d\u044b\u0439 \u043f\u043e\u0442\u0435\u043d\u0446\u0438\u043e\u043c\u0435\u0442\u0440 \u0438\u043b\u0438 \u043e\u043f\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u044d\u043d\u043a\u043e\u0434\u0435\u0440, \u043f\u0440\u0438\u043a\u0440\u0435\u043f\u043b\u0435\u043d\u043d\u044b\u0439 \u043a \u0434\u0432\u0438\u0436\u0443\u0449\u0435\u043c\u0443\u0441\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u043c\u0443 \u0432\u0430\u043b\u0443 (\u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u0443\u0435\u0442 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u0432 \u0441\u0438\u0433\u043d\u0430\u043b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f)<\/li>\n\n\n\n<li><strong>\u0412\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430<\/strong>: \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u043e\u0440\u0438\u0435\u043d\u0442\u0438\u0440\u043e\u0432 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f (\u043c\u0435\u043d\u0435\u0435 \u0442\u043e\u0447\u043d\u043e, \u0447\u0435\u043c \u0434\u0430\u0442\u0447\u0438\u043a, \u043d\u043e \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043a\u0440\u0435\u043f\u043b\u0435\u043d\u0438\u044f)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u041f\u043e\u0448\u0430\u0433\u043e\u0432\u0430\u044f \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0430<\/strong>:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-1-safety-and-preparation-10-minutes\">\u0428\u0430\u0433 1: \u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u043e\u0434\u0433\u043e\u0442\u043e\u0432\u043a\u0430 (10 \u043c\u0438\u043d\u0443\u0442)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432\u044b\u0434\u0432\u0438\u043d\u0443\u0442, \u043f\u0438\u0442\u0430\u043d\u0438\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u043e, \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0440\u0430\u0437\u0440\u044f\u0436\u0435\u043d\u044b.<\/li>\n\n\n\n<li>\u041f\u0440\u0438\u043a\u0440\u0435\u043f\u0438\u0442\u0435 \u0434\u0430\u0442\u0447\u0438\u043a \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u043a \u0434\u0432\u0438\u0436\u0443\u0449\u0435\u043c\u0443\u0441\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u043c\u0443 \u0432\u0430\u043b\u0443 (\u0441\u043b\u0435\u0434\u0443\u0439\u0442\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u043f\u043e \u043c\u043e\u043d\u0442\u0430\u0436\u0443).<\/li>\n\n\n\n<li>\u041f\u043e\u0434\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0432\u044b\u0445\u043e\u0434 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0430\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u043a \u043a\u0430\u0442\u0443\u0448\u043a\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u0441\u043e\u0431\u043b\u044e\u0434\u0430\u0439\u0442\u0435 \u043f\u043e\u043b\u044f\u0440\u043d\u043e\u0441\u0442\u044c).<\/li>\n\n\n\n<li>\u041f\u043e\u0434\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0432\u0445\u043e\u0434\u044b \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043a \u0430\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440\u0443 (\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b NO \u0438 NC)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-2-initial-trip-test-5-minutes\">\u0428\u0430\u0433 2: \u041f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043f\u043e\u0435\u0437\u0434\u043a\u0438 (5 \u043c\u0438\u043d\u0443\u0442)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0417\u0430\u043c\u043a\u043d\u0443\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0432\u0440\u0443\u0447\u043d\u0443\u044e<\/li>\n\n\n\n<li>\u0410\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440 \u043f\u043e\u0434\u0430\u0435\u0442 \u043d\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0443 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430.<\/li>\n\n\n\n<li>\u0417\u0430\u043f\u0438\u0441\u044c \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f (\u043c\u043e\u043c\u0435\u043d\u0442 \u043f\u043e\u0434\u0430\u0447\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0443 \u2192 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430)<\/li>\n\n\n\n<li>\u0417\u0430\u0445\u0432\u0430\u0442 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f (\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043f\u043e \u043e\u0442\u043d\u043e\u0448\u0435\u043d\u0438\u044e \u043a\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0432 \u043e\u043a\u043d\u0435 0\u2013100 \u043c\u0441)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f<\/strong>: \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u2264 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 + 10%, \u043a\u0440\u0438\u0432\u0430\u044f \u0445\u043e\u0434\u0430 \u043f\u043b\u0430\u0432\u043d\u0430\u044f \u0441 \u0432\u0438\u0434\u0438\u043c\u044b\u043c \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u0435\u043c \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-3-voltage-variation-test-15-minutes\">\u0428\u0430\u0433 3: \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (15 \u043c\u0438\u043d\u0443\u0442)<\/h3>\n\n\n\n<p>\u041f\u0440\u043e\u0432\u0435\u0434\u0438\u0442\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f 80%, 100% \u0438 110%. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 70-110%.<\/p>\n\n\n\n<p><strong>\u041e\u0436\u0438\u0434\u0430\u0435\u043c\u044b\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u043a\u043e\u043b\u0435\u0431\u0430\u043d\u0438\u044f<\/strong>:<br>\u2022 \u041f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 110%: \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442\u0441\u044f \u043d\u0430 5-10% (\u0431\u043e\u043b\u0435\u0435 \u0441\u0438\u043b\u044c\u043d\u0430\u044f \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u0430\u044f \u0441\u0438\u043b\u0430, \u0431\u043e\u043b\u0435\u0435 \u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0437\u0430\u0449\u0435\u043b\u043a\u0438)<br>\u2022 \u041f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 80%: \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u043d\u0430 10-15% (\u043c\u0435\u043d\u044c\u0448\u0430\u044f \u0441\u0438\u043b\u0430, \u0431\u043e\u043b\u0435\u0435 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435)<br>\u2022 \u041f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 70%: \u043c\u043e\u0436\u0435\u0442 \u043d\u0435 \u0441\u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c (\u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u0441\u0438\u043b\u0430 \u0434\u043b\u044f \u043e\u0441\u0432\u043e\u0431\u043e\u0436\u0434\u0435\u043d\u0438\u044f \u0437\u0430\u0449\u0435\u043b\u043a\u0438)<br>\u0415\u0441\u043b\u0438 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 20% \u0432 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439, \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0438\u043b\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0441\u0432\u044f\u0437\u044c.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-4-close-operation-test-5-minutes\">\u0428\u0430\u0433 4: \u0417\u0430\u0432\u0435\u0440\u0448\u0435\u043d\u0438\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f (5 \u043c\u0438\u043d\u0443\u0442)<\/h3>\n\n\n\n<p>\u041f\u043e\u0432\u0442\u043e\u0440\u0438\u0442\u0435 \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0443 \u0434\u043b\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f. \u0412\u0440\u0435\u043c\u044f \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u043e\u0431\u044b\u0447\u043d\u043e \u043c\u0435\u043d\u044c\u0448\u0435, \u0447\u0435\u043c \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f (20\u201335 \u043c\u0441), \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043f\u0440\u0443\u0436\u0438\u043d\u0430 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u0431\u043e\u043b\u0435\u0435 \u0441\u0438\u043b\u044c\u043d\u0430\u044f \u2014 \u043e\u043d\u0430 \u0434\u043e\u043b\u0436\u043d\u0430 \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u0442\u044c \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u0443 \u0441\u0436\u0430\u0442\u0438\u044f.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-5-multi-operation-test-30-minutes\">\u0428\u0430\u0433 5: \u0422\u0435\u0441\u0442 \u043d\u0430 \u043c\u043d\u043e\u0433\u043e\u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0441\u0442\u044c (30 \u043c\u0438\u043d\u0443\u0442)<\/h3>\n\n\n\n<p>\u0412\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u0435 10 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0446\u0438\u043a\u043b\u043e\u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f-\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u0441 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u043e\u043c 30 \u0441\u0435\u043a\u0443\u043d\u0434. \u0417\u0430\u043f\u0438\u0448\u0438\u0442\u0435 \u0432\u0440\u0435\u043c\u044f \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438.<\/p>\n\n\n\n<p><strong>\u041f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0438 \u0434\u0435\u0433\u0440\u0430\u0434\u0430\u0446\u0438\u0438<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0421\u043c\u0435\u0449\u0435\u043d\u0438\u0435 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 &gt;5 \u043c\u0441 \u0437\u0430 10 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439: \u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u0441\u043c\u0430\u0437\u043a\u0430 (\u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0442\u0440\u0435\u043d\u0438\u044f)<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0444\u043e\u0440\u043c\u044b \u043a\u0440\u0438\u0432\u043e\u0439 \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f: \u043d\u0430\u0433\u0440\u0435\u0432 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 (\u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u0438 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438)<\/li>\n<\/ul>\n\n\n\n<p>\u0414\u043b\u044f \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u0438\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438 \u043e \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u044b\u0445 \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0430\u0445 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0441\u043c.&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vcb-fat-sat-acceptance-test-checklist\/\">\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0434\u043b\u044f \u0441\u0434\u0430\u0447\u0438 \u044d\u043a\u0437\u0430\u043c\u0435\u043d\u0430 VCB FAT\/SAT<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03.webp\" alt=\"\u0421\u0445\u0435\u043c\u0430 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 VCB, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0430\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u043a \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u0434\u0430\u0442\u0447\u0438\u043a\u0443 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f\" class=\"wp-image-2427\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 3. \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439: \u0430\u043d\u0430\u043b\u0438\u0437\u0430\u0442\u043e\u0440 VCB \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u0435\u0442\u0441\u044f \u043a \u043a\u0430\u0442\u0443\u0448\u043a\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0439 \u0442\u043e\u043a \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b), \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c (\u0441\u0432\u0435\u0442\u043e\u0432\u044b\u0435 \u0441\u0438\u0433\u043d\u0430\u043b\u044b) \u0438 \u0434\u0430\u0442\u0447\u0438\u043a\u0443 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f (\u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f). \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u043b\u0438\u0441\u044c \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f 80%, 100% \u0438 110% \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 IEC 62271-100.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"troubleshooting-timing-deviations-root-causes-and-fixes\">\u0423\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0439 \u0432 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438: \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0440\u0438\u0447\u0438\u043d\u044b \u0438 \u0441\u043f\u043e\u0441\u043e\u0431\u044b \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<p>\u041a\u043e\u0433\u0434\u0430 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438, \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u0430 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c, \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043b\u0438 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 (\u043f\u0440\u0443\u0436\u0438\u043d\u044b, \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u044b, \u0441\u043c\u0430\u0437\u043a\u0430), \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 (\u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438, \u043c\u0430\u0433\u043d\u0438\u0442 \u0437\u0430\u0449\u0435\u043b\u043a\u0438) \u0438\u043b\u0438 \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u043e\u0439 \u0441 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u043e\u0439.<\/p>\n\n\n\n<p><strong>\u0414\u0435\u0440\u0435\u0432\u043e \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0440\u0435\u0448\u0435\u043d\u0438\u0439<\/strong>:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-1-opening-time-10-20-slower-than-rated\">\u0421\u0438\u043c\u043f\u0442\u043e\u043c 1: \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f 10-20% \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u0435\u0435, \u0447\u0435\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435<\/h3>\n\n\n\n<p><strong>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043f\u0440\u0438\u0447\u0438\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0421\u043b\u0430\u0431\u044b\u0439 \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0438\u0439\u0441\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u0438\u0441\u0442\u044b\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c<\/strong>: \u041d\u0430\u0442\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0443\u0445\u0443\u0434\u0448\u0438\u043b\u043e\u0441\u044c \u0438\u0437-\u0437\u0430 \u0438\u0437\u043d\u043e\u0441\u0430\/\u0443\u0441\u0442\u0430\u043b\u043e\u0441\u0442\u0438\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0441\u0436\u0430\u0442\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0434\u0438\u043d\u0430\u043c\u043e\u043c\u0435\u0442\u0440\u0430 (\u0434\u043e\u043b\u0436\u043d\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c \u0434\u0430\u043d\u043d\u044b\u043c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u0430 \u00b110%).<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0417\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u0443\u0437\u0435\u043b \u043e\u0442\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u0443\u0436\u0438\u043d\u044b<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u041f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0435 \u0442\u0440\u0435\u043d\u0438\u0435<\/strong>: \u0421\u0443\u0445\u0438\u0435 \u0448\u0430\u0440\u043d\u0438\u0440\u044b \u0438\u043b\u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u043d\u044b\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u0412\u0440\u0443\u0447\u043d\u0443\u044e \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c \u0442\u043e\u0447\u043a\u0438 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u041e\u0447\u0438\u0441\u0442\u0438\u0442\u0435 \u0438 \u0441\u043c\u0430\u0436\u044c\u0442\u0435 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u044f\u043c\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f (\u043e\u0431\u044b\u0447\u043d\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043c\u043e\u043b\u0438\u0431\u0434\u0435\u043d\u043e\u0432\u0430\u044f \u0434\u0438\u0441\u0443\u043b\u044c\u0444\u0438\u0434\u043d\u0430\u044f \u0441\u043c\u0430\u0437\u043a\u0430).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0418\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u043e\u0435 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u0430\u0448\u043f\u043e\u0442\u0430<\/strong>: \u0416\u0438\u0434\u043a\u043e\u0441\u0442\u044c \u0432 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0435 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0432\u044f\u0437\u043a\u0430\u044f (\u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u0442\u0438\u043f \u0438\u043b\u0438 \u043d\u0438\u0437\u043a\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430)\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u041a\u0440\u0438\u0432\u0430\u044f \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0440\u0430\u043d\u043d\u0435\u0435 \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u0435 (\u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0440\u0430\u043d\u043d\u0435\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430).<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0417\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u044c \u0432 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0435 \u043d\u0430 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u044c \u0441 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043a\u043b\u0430\u0441\u0441\u043e\u043c \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u0438.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-2-opening-time-varies-15-between-operations\">\u0421\u0438\u043c\u043f\u0442\u043e\u043c 2: \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0432\u0430\u0440\u044c\u0438\u0440\u0443\u0435\u0442\u0441\u044f &gt;15% \u043c\u0435\u0436\u0434\u0443 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u043c\u0438<\/h3>\n\n\n\n<p><strong>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043f\u0440\u0438\u0447\u0438\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0418\u0437\u043d\u043e\u0441 \u0437\u0430\u0449\u0435\u043b\u043a\u0438<\/strong>: \u041f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0449\u0435\u043b\u043a\u0438 \u0438\u0437\u043d\u043e\u0448\u0435\u043d\u0430, \u0442\u043e\u0447\u043a\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u0430.\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440 \u043d\u0430 \u043f\u0440\u0435\u0434\u043c\u0435\u0442 \u043d\u0430\u043b\u0438\u0447\u0438\u044f \u0442\u043e\u0447\u0435\u0447\u043d\u043e\u0439 \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u0438 \u0438\u043b\u0438 \u0434\u0435\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0417\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u0437\u0430\u043c\u043e\u043a<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u041d\u0430\u0433\u0440\u0435\u0432 \u043a\u0430\u0442\u0443\u0448\u043a\u0438<\/strong>: \u0423\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u043f\u0440\u0438 \u043c\u043d\u043e\u0433\u043e\u043a\u0440\u0430\u0442\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u0445\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0432 \u0445\u043e\u043b\u043e\u0434\u043d\u043e\u043c \u0438 \u0433\u043e\u0440\u044f\u0447\u0435\u043c \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0438 (\u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0434\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c &lt;15%).<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u0415\u0441\u043b\u0438 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435 &gt;20%, \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0443.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-3-travel-curve-shows-no-dashpot-deceleration\">\u0421\u0438\u043c\u043f\u0442\u043e\u043c 3: \u041a\u0440\u0438\u0432\u0430\u044f \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f \u043d\u0435 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u044f \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430<\/h3>\n\n\n\n<p><strong>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043f\u0440\u0438\u0447\u0438\u043d\u044b<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0423\u0442\u0435\u0447\u043a\u0430 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0438\u0437 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430<\/strong>: \u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0443\u043f\u043b\u043e\u0442\u043d\u0435\u043d\u0438\u044f \u043f\u043e\u0440\u0448\u043d\u044f, \u043f\u043e\u0442\u0435\u0440\u044f \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0446\u0438\u0438\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440 \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u043c\u0430\u0441\u043b\u044f\u043d\u044b\u0445 \u043e\u0441\u0442\u0430\u0442\u043a\u043e\u0432 \u0432\u043e\u043a\u0440\u0443\u0433 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u041f\u0435\u0440\u0435\u0434\u0435\u043b\u0430\u0442\u044c \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440 \u0441 \u043d\u043e\u0432\u044b\u043c\u0438 \u0443\u043f\u043b\u043e\u0442\u043d\u0435\u043d\u0438\u044f\u043c\u0438 \u0438 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u044c\u044e<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430<\/strong>: \u041f\u043e\u0440\u0448\u0435\u043d\u044c \u043d\u0435 \u0432\u0445\u043e\u0434\u0438\u0442 \u0432 \u0437\u0430\u0446\u0435\u043f\u043b\u0435\u043d\u0438\u0435 \u0434\u043e\u043b\u0436\u043d\u044b\u043c \u043e\u0431\u0440\u0430\u0437\u043e\u043c\n<ul class=\"wp-block-list\">\n<li><strong>\u0422\u0435\u0441\u0442<\/strong>: \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043b\u0438 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u0437\u0430\u0446\u0435\u043f\u043b\u0435\u043d\u0438\u044f \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f.<\/li>\n\n\n\n<li><strong>\u0418\u0441\u043f\u0440\u0430\u0432\u0438\u0442\u044c<\/strong>: \u041e\u0442\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e\u043c \u043f\u043e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u041a\u043e\u0440\u0440\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u043a\u0430 \u0441\u0440\u043e\u043a\u043e\u0432 \u0438\u043b\u0438 \u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u043e \u0437\u0430\u043c\u0435\u043d\u0435<\/strong>:<br>\u2022\u00a0<strong>\u041d\u0430\u0441\u0442\u0440\u043e\u0438\u0442\u044c<\/strong>: \u0412\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 80-110%, \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u0432\u043e \u0432\u0441\u0435\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u0445, \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043d\u0435\u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0441\u043c\u0430\u0437\u043a\u0430<br>\u2022\u00a0<strong>\u0420\u0435\u043c\u043e\u043d\u0442<\/strong>: \u0412\u0440\u0435\u043c\u044f 110-125% \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435, \u0438\u0437\u043d\u043e\u0441 \u043f\u0440\u0443\u0436\u0438\u043d\u044b\/\u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430, \u043d\u043e \u0431\u0435\u0437 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u043d\u044b\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439<br>\u2022\u00a0<strong>\u0417\u0430\u043c\u0435\u043d\u0438\u0442\u044c<\/strong>: \u0412\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f &gt;125%, \u043c\u043d\u043e\u0436\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043e\u0442\u043a\u0430\u0437\u044b (\u043f\u0440\u0443\u0436\u0438\u043d\u044b + \u0437\u0430\u0449\u0435\u043b\u043a\u0430 + \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b) \u0438\u043b\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u043e\u043b\u043e\u043c\u043a\u0438<\/p>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043d\u0430 85 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u043e, \u0447\u0442\u043e 70% \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0439 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0431\u044b\u043b\u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u044b \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u043c\u0430\u0437\u043a\u0438 \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430, 20% \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u044b \u043f\u0440\u0443\u0436\u0438\u043d\u044b, \u0430 10% \u2014 \u043f\u043e\u043b\u043d\u043e\u0433\u043e \u043a\u0430\u043f\u0438\u0442\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"relationship-between-closing-time-and-contact-bounce\">\u0421\u0432\u044f\u0437\u044c \u043c\u0435\u0436\u0434\u0443 \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u0438 \u043e\u0442\u043a\u0430\u0437\u043e\u043c \u043e\u0442 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430<\/h2>\n\n\n\n<p>\u0417\u0430\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0438\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u0434\u043e\u043b\u0436\u043d\u044b \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f (\u043e\u0431\u044b\u0447\u043d\u043e 20-35 \u043c\u0441), \u043d\u043e \u0438 \u043c\u0438\u043d\u0438\u043c\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u2014 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0435 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u043e\u0441\u043b\u0435 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0441\u043e\u043f\u0440\u0438\u043a\u043e\u0441\u043d\u043e\u0432\u0435\u043d\u0438\u044f \u0438\u0437-\u0437\u0430 \u043a\u0438\u043d\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u0427\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u044b\u0439 \u043e\u0442\u0441\u043a\u043e\u043a \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044e \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0434\u0443\u0433\u0438 (\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0441\u0432\u0430\u0440\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0434\u043e \u043f\u043e\u043b\u043d\u043e\u0433\u043e \u0441\u0436\u0430\u0442\u0438\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u044b) \u0438 \u0443\u0441\u043a\u043e\u0440\u044f\u0435\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0438\u0437\u043d\u043e\u0441.<\/p>\n\n\n\n<p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u0430\u043a \u0440\u0430\u0441\u043a\u0440\u044b\u0442\u0438\u0435 \u22650,3 \u043c\u043c \u043f\u043e\u0441\u043b\u0435 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u0412 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 VCB \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0433\u0438\u0434\u0440\u0430\u0432\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u044b \u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0435 \u0431\u0443\u0444\u0435\u0440\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u044e\u0442 \u043e\u0442\u0441\u043a\u043e\u043a \u0434\u043e &lt;0,1 \u043c\u043c.<\/p>\n\n\n\n<p><strong>\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u043e\u0442\u0441\u043a\u043e\u043a\u0430 \u043f\u043e \u043a\u0440\u0438\u0432\u043e\u0439 \u0445\u043e\u0434\u0430<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0417\u0430\u0445\u0432\u0430\u0442 \u043a\u0440\u0438\u0432\u043e\u0439 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435\u043c (\u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0434\u0438\u0441\u043a\u0440\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u226510 \u043a\u0413\u0446)<\/li>\n\n\n\n<li>\u041e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c \u043c\u043e\u043c\u0435\u043d\u0442 \u043f\u0435\u0440\u0432\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 (\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435 \u043f\u0435\u0440\u0435\u0441\u0442\u0430\u0435\u0442 \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0442\u044c\u0441\u044f)<\/li>\n\n\n\n<li>\u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u043b\u044e\u0431\u043e\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0435 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u043f\u043e\u0437\u0438\u0446\u0438\u0438 (\u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043e\u0442\u0441\u043a\u043e\u043a\/\u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u0435)<\/li>\n\n\n\n<li>\u0420\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u0442\u044c \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0438 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u0442\u0441\u043a\u043e\u043a\u0430<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0414\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u0435 \u043f\u0440\u0435\u0434\u0435\u043b\u044b \u043e\u0442\u0441\u043a\u043e\u043a\u0430<\/strong>:<br>\u2022\u00a0<strong>\u0420\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435<\/strong>: &lt;0,3 \u043c\u043c (\u043f\u0440\u0435\u0434\u0435\u043b \u043f\u043e \u041c\u042d\u041a), &lt;0,1 \u043c\u043c (\u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0434\u043b\u044f \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b)<br>\u2022\u00a0<strong>\u041f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c<\/strong>: &lt;2 \u043c\u0441 (\u0431\u043e\u043b\u044c\u0448\u0430\u044f \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u2192 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u0434\u0443\u0433\u043e\u0439)<br>\u2022\u00a0<strong>\u0413\u0440\u0430\u0444<\/strong>: \u0414\u043e\u043f\u0443\u0441\u0442\u0438\u043c \u043e\u0434\u0438\u043d \u043e\u0442\u0441\u043a\u043e\u043a, \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043e\u0442\u0441\u043a\u043e\u043a\u043e\u0432 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0435 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435.<\/p>\n\n\n\n<p><strong>\u041f\u0440\u0438\u0447\u0438\u043d\u044b \u0447\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u043e\u0433\u043e \u043e\u0442\u0441\u043a\u043e\u043a\u0430<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0417\u0430\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u0430 \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0436\u0435\u0441\u0442\u043a\u0430\u044f (\u0438\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u0430\u044f \u043a\u0438\u043d\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u044f)<\/li>\n\n\n\n<li>\u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0435 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 (\u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u044c \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438)<\/li>\n\n\n\n<li>\u041d\u0435\u0440\u043e\u0432\u043d\u0430\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u0430\u044f \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u044c (\u0432 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u0435 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u044b\u0431\u043e\u0438\u043d \u043e\u0442 \u043f\u0440\u0435\u0434\u044b\u0434\u0443\u0449\u0438\u0445 \u0434\u0443\u0433\u043e\u0432\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432 \u0432\u043e\u0437\u043d\u0438\u043a\u0430\u0435\u0442 \u043d\u0435\u0440\u043e\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u043f\u0440\u0438\u043a\u043e\u0441\u043d\u043e\u0432\u0435\u043d\u0438\u0438)<\/li>\n<\/ul>\n\n\n\n<p>\u041f\u043e\u043b\u0435\u0432\u044b\u0435 \u0434\u0430\u043d\u043d\u044b\u0435 60 VCB \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438, \u0447\u0442\u043e \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u043b\u0438\u043d\u0435\u0439\u043d\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0441 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b: \u0443 \u043d\u043e\u0432\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u043e\u043d \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u043c 0,05 \u043c\u043c, \u0443 10-\u043b\u0435\u0442\u043d\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u2014 0,15 \u043c\u043c, \u0443 20-\u043b\u0435\u0442\u043d\u0438\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u2014 0,35 \u043c\u043c (\u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044f \u043f\u0440\u0435\u0434\u0435\u043b\u044b, \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0435 IEC). \u0420\u0435\u043c\u043e\u043d\u0442 \u0441 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435\u043c \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435\u043c \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u043e\u0442\u0441\u043a\u043e\u043a \u0434\u043e &lt;0,1 \u043c\u043c.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04.webp\" alt=\"\u0413\u0440\u0430\u0444\u0438\u043a, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u043a\u0440\u0438\u0432\u0443\u044e \u0445\u043e\u0434\u0430 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f VCB \u0441 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435\u043c \u043e\u0442\u0441\u043a\u043e\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0441 \u0430\u043c\u043f\u043b\u0438\u0442\u0443\u0434\u043e\u0439 0,2 \u043c\u043c \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f IEC 62271-100\" class=\"wp-image-2426\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0420\u0438\u0441\u0443\u043d\u043e\u043a 4. \u041a\u0440\u0438\u0432\u0430\u044f \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430: \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u0430\u0441\u0430\u043d\u0438\u0435 \u0447\u0435\u0440\u0435\u0437 25 \u043c\u0441, \u0437\u0430 \u043a\u043e\u0442\u043e\u0440\u044b\u043c \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043e\u0442\u0441\u043a\u043e\u043a \u043d\u0430 0,2 \u043c\u043c (\u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c 1,5 \u043c\u0441) \u2014 \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f IEC 62271-100 (<0.3 mm). Excessive bounce (>0,3 \u043c\u043c) \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0435 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438\u043b\u0438 \u043d\u0435\u0440\u043e\u0432\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0443\u044e \u0440\u0435\u043c\u043e\u043d\u0442\u0430.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"timing-test-frequency-and-recordkeeping\">\u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u043f\u0440\u043e\u0432\u0435\u0434\u0435\u043d\u0438\u044f \u0442\u0435\u0441\u0442\u043e\u0432 \u043d\u0430 \u0441\u0432\u043e\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0441\u0442\u044c \u0438 \u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0443\u0447\u0435\u0442\u0430<\/h2>\n\n\n\n<p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b IEC 62271-100 \u0438 IEEE C37.09 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u044e\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u043b\u044f \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u0442\u0435\u043f\u0435\u043d\u043d\u043e\u0433\u043e \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u044f \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0434\u043e \u0432\u044b\u0445\u043e\u0434\u0430 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f. \u0427\u0430\u0441\u0442\u043e\u0442\u0430 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0438 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f.<\/p>\n\n\n\n<p><strong>\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430\u043c\u0438<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0412\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/strong>: \u041f\u043e\u043b\u043d\u044b\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0438 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u043f\u0438\u0442\u0430\u043d\u0438\u044f<\/li>\n\n\n\n<li><strong>\u0415\u0436\u0435\u0433\u043e\u0434\u043d\u043e (\u043f\u0435\u0440\u0432\u044b\u0435 5 \u043b\u0435\u0442)<\/strong>: \u0422\u043e\u043b\u044c\u043a\u043e \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f (\u0431\u044b\u0441\u0442\u0440\u043e\u0435 \u043f\u043e\u043b\u0435\u0432\u043e\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435)<\/li>\n\n\n\n<li><strong>\u0414\u0432\u0443\u0445\u0433\u043e\u0434\u0438\u0447\u043d\u044b\u0439 (6\u201315 \u043b\u0435\u0442)<\/strong>: \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f + \u043a\u0440\u0438\u0432\u044b\u0435 \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f<\/li>\n\n\n\n<li><strong>\u0415\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0439 (&gt;15 \u043b\u0435\u0442 \u0438\u043b\u0438 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u0430\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f)<\/strong>: \u041f\u043e\u043b\u043d\u044b\u0439 \u0430\u043d\u0430\u043b\u0438\u0437, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u043c\u043d\u043e\u0433\u043e\u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f<\/li>\n<\/ol>\n\n\n\n<p><strong>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0432\u0435\u0434\u0435\u043d\u0438\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438<\/strong>: \u0421\u043e\u0445\u0440\u0430\u043d\u044f\u0439\u0442\u0435 \u0431\u0430\u0437\u043e\u0432\u044b\u0435 \u043a\u0440\u0438\u0432\u044b\u0435 \u0441 \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0438 \u0434\u0430\u043d\u043d\u044b\u0435 \u043e \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u044f\u0445, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0435 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a. \u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043a\u043e\u0442\u043e\u0440\u043e\u0433\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u043b\u043e\u0441\u044c \u0441 32 \u043c\u0441 (\u043d\u043e\u0432\u044b\u0439) \u0434\u043e 38 \u043c\u0441 (10-\u0439 \u0433\u043e\u0434) \u0438 \u0434\u043e 44 \u043c\u0441 (15-\u0439 \u0433\u043e\u0434), \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u0435\u0442 \u043f\u0440\u0435\u0434\u0441\u043a\u0430\u0437\u0443\u0435\u043c\u043e\u0435 \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u2014 \u0437\u0430\u043f\u043b\u0430\u043d\u0438\u0440\u0443\u0439\u0442\u0435 \u0440\u0435\u043c\u043e\u043d\u0442 \u0434\u043e \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u0440\u0435\u0432\u044b\u0441\u0438\u0442 48 \u043c\u0441 (120% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f 40 \u043c\u0441).<\/p>\n\n\n\n<p><strong>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433<\/strong>: \u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b (SEL-487V, ABB REM615) \u0438\u0437\u043c\u0435\u0440\u044f\u044e\u0442 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u0440\u0438 \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e\u043c \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0442\u043e\u043a\u0430 (\u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u043c\u043e\u043c\u0435\u043d\u0442 \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u043e \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044e \u0434\u0443\u0433\u043e\u0432\u043e\u0433\u043e \u0442\u043e\u043a\u0430). \u042d\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043e\u0442\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0442\u044c \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0438 \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0431\u0435\u0437 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u041c\u044b \u0432\u043d\u0435\u0434\u0440\u0438\u043b\u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u043d\u0430 40 VCB; 6 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 (15%) \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u044e \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u044f \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u0435\u043b\u043e \u043a \u0438\u0445 \u043c\u043e\u0434\u0435\u0440\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0437\u0430 12\u201318 \u043c\u0435\u0441\u044f\u0446\u0435\u0432 \u0434\u043e \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u043e\u043d\u0438 \u043f\u0440\u043e\u0432\u0430\u043b\u0438\u043b\u0438 \u0431\u044b \u0442\u0435\u0441\u0442\u044b \u043d\u0430 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044e, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u043b\u043e \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0432\u044b\u043d\u0443\u0436\u0434\u0435\u043d\u043d\u044b\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f.<\/p>\n\n\n\n<p>\u0414\u043b\u044f \u043e\u0446\u0435\u043d\u043a\u0438 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u0432\u044b\u0445\u043e\u0434\u044f\u0449\u0435\u0439 \u0437\u0430 \u0440\u0430\u043c\u043a\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u0432\u0440\u0435\u043c\u044f, \u0441\u043c.&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/vacuum-interrupter-contact-wear-replacement-guide\/\">\u0418\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 VCB \u0438 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043e\u043a\u043e\u043d\u0447\u0430\u043d\u0438\u044f \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b<\/a>.<\/p>\n\n\n<p>\u0414\u043b\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u043b\u0438\u044f\u044e\u0442 \u043d\u0430 \u043f\u043e\u0432\u0442\u043e\u0440\u044f\u0435\u043c\u043e\u0441\u0442\u044c \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438, \u0434\u043e\u0431\u0430\u0432\u044c\u0442\u0435 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0435&nbsp;<a href=\"https:\/\/xbrele.com\/ru\/drawout-vcb-racking-safety-shutters-alignment-checks\/\">\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0434\u043b\u044f \u0432\u044b\u0442\u044f\u0433\u0438\u0432\u0430\u043d\u0438\u044f \u0441\u0442\u0435\u043b\u043b\u0430\u0436\u0435\u0439 VCB \u0438 \u0432\u044b\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u043d\u0438\u044f<\/a>&nbsp;\u0432 \u043f\u043b\u0430\u043d \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439.<\/p>\n\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\n\n\n\n<p>\u0422\u0435\u0441\u0442\u044b \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 VCB \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442, \u0447\u0442\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c IEC 62271-100, \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u044f, \u0447\u0442\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0440\u0432\u0430\u0442\u044c \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043e \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439. \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f (\u043e\u0431\u044b\u0447\u043d\u043e 30-50 \u043c\u0441) \u0434\u043e\u043b\u0436\u043d\u043e \u043e\u0441\u0442\u0430\u0432\u0430\u0442\u044c\u0441\u044f \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f +10%, \u0447\u0442\u043e\u0431\u044b \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0447\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u043e\u0435 \u043d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u0438\u0435 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438 (&gt;2 \u043a\u0414\u0436 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u043c\u0443 \u0432\u044b\u0445\u043e\u0434\u0443 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f). \u0410\u043d\u0430\u043b\u0438\u0437 \u043a\u0440\u0438\u0432\u043e\u0439 \u0445\u043e\u0434\u0430 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435: \u043f\u043b\u0430\u0432\u043d\u043e\u0435 \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0443\u0436\u0438\u043d \u0438 \u0441\u043c\u0430\u0437\u043a\u0438, \u0432\u0438\u0434\u0438\u043c\u043e\u0435 \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u0435 \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0442 \u0443\u0434\u0430\u0440\u0430, \u0430 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (&lt;0,3 \u043c\u043c \u043f\u043e IEC, \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e &lt;0,1 \u043c\u043c) \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0438\u0437\u043d\u043e\u0441 \u043f\u0435\u0440\u0435\u0434 \u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0434\u0443\u0433\u0438.<\/p>\n\n\n\n<p>\u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438\u0437\u043c\u0435\u0440\u044f\u044e\u0442 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 80-110%, \u0444\u0438\u043a\u0441\u0438\u0440\u0443\u044e\u0442 \u043a\u0440\u0438\u0432\u044b\u0435 \u0445\u043e\u0434\u0430 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043b\u0438\u043d\u0435\u0439\u043d\u044b\u0445 \u0434\u0430\u0442\u0447\u0438\u043a\u043e\u0432 \u0438\u043b\u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u044e\u0442 \u043c\u043d\u043e\u0433\u043e\u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0439 \u043a \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u044e \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a. \u0423\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0439 \u0432\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0437\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u043e\u0439: \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u0435 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u0441\u043b\u0430\u0431\u044b\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438\u043b\u0438 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0435 \u0442\u0440\u0435\u043d\u0438\u0435 (\u0441\u043c\u0430\u0437\u043a\u0430, \u0437\u0430\u043c\u0435\u043d\u0430 \u043f\u0440\u0443\u0436\u0438\u043d), \u0438\u0437\u043c\u0435\u043d\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u0438\u0437\u043d\u043e\u0441 \u0437\u0430\u0449\u0435\u043b\u043a\u0438 \u0438\u043b\u0438 \u043d\u0430\u0433\u0440\u0435\u0432 \u043a\u0430\u0442\u0443\u0448\u043a\u0438, \u0430 \u043f\u043e\u0442\u0435\u0440\u044f \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u044f \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u0441\u0438\u0433\u043d\u0430\u043b\u0438\u0437\u0438\u0440\u0443\u0435\u0442 \u043e\u0431 \u0443\u0442\u0435\u0447\u043a\u0435 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0438\u043b\u0438 \u043e\u0448\u0438\u0431\u043a\u0430\u0445 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438.<\/p>\n\n\n\n<p>\u041a\u043b\u044e\u0447\u0435\u0432\u0430\u044f \u0438\u0434\u0435\u044f: \u0442\u0435\u0441\u0442\u044b \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0437\u0430\u0440\u0430\u043d\u0435\u0435 \u043f\u0440\u0435\u0434\u0443\u043f\u0440\u0435\u0434\u0438\u0442\u044c \u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u0438\u0437\u043d\u043e\u0441\u0435 \u0437\u0430 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u043c\u0435\u0441\u044f\u0446\u0435\u0432 \u0438\u043b\u0438 \u043b\u0435\u0442 \u0434\u043e \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u043e\u043b\u043e\u043c\u043a\u0438. \u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043a\u043e\u0442\u043e\u0440\u043e\u0433\u043e \u0437\u0430 10 \u043b\u0435\u0442 \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u043b\u043e\u0441\u044c \u0441 35 \u0434\u043e 42 \u043c\u0441, \u0434\u0435\u043c\u043e\u043d\u0441\u0442\u0440\u0438\u0440\u0443\u0435\u0442 \u043f\u0440\u0435\u0434\u0441\u043a\u0430\u0437\u0443\u0435\u043c\u044b\u0439 \u0438\u0437\u043d\u043e\u0441, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u043f\u043b\u0430\u043d\u043e\u0432\u044b\u0439 \u0440\u0435\u043c\u043e\u043d\u0442 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0437\u0430\u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u043a, \u0430 \u043d\u0435 \u044d\u043a\u0441\u0442\u0440\u0435\u043d\u043d\u0443\u044e \u0437\u0430\u043c\u0435\u043d\u0443 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439. \u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b (\u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438) \u043f\u0440\u0435\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u0442\u0435\u0441\u0442\u044b \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0438\u0437 \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043c\u043e\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u0441\u043d\u0438\u043c\u043a\u043e\u0432 \u0432 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u0443\u044e \u043e\u0446\u0435\u043d\u043a\u0443 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044f \u0443\u043b\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0438 \u0438\u0437\u043d\u043e\u0441\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0435 \u0432\u0438\u0434\u043d\u044b \u043f\u0440\u0438 \u0435\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0445 \u0442\u0435\u0441\u0442\u0430\u0445.<\/p>\n\n\n\n<p>\u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0441\u0440\u043e\u043a\u043e\u0432 \u0438 \u0430\u043d\u0430\u043b\u0438\u0437 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0439 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u043f\u0435\u0440\u0435\u0439\u0442\u0438 \u043e\u0442 \u0440\u0435\u0430\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f VCB (\u0437\u0430\u043c\u0435\u043d\u0430 \u043f\u0440\u0438 \u0432\u044b\u0445\u043e\u0434\u0435 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f) \u043a \u043f\u0440\u043e\u0433\u043d\u043e\u0437\u0438\u0440\u0443\u0435\u043c\u043e\u043c\u0443 (\u0440\u0435\u043c\u043e\u043d\u0442 \u043f\u0440\u0438 \u043f\u0440\u0438\u0431\u043b\u0438\u0436\u0435\u043d\u0438\u0438 \u043a \u043f\u0440\u0435\u0434\u0435\u043b\u0443 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b), \u0447\u0442\u043e \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0434\u043b\u0435\u0432\u0430\u0435\u0442 \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0449\u0438\u0442\u044b \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u0431\u043e\u0435\u0432 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vcb-timing-test--travel-curves\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b: \u0422\u0435\u0441\u0442 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 VCB \u0438 \u043a\u0440\u0438\u0432\u044b\u0435 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f<\/h2>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 1: \u041a\u0430\u043a\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u044b\u043c \u0434\u043b\u044f VCB \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f 40 \u043c\u0441 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 IEC 62271-100?<\/strong><\/p>\n\n\n\n<p>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u0434\u043e\u043f\u0443\u0441\u043a\u0430\u0435\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0434\u043e 110% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f. \u0414\u043b\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0435\u043c 40 \u043c\u0441 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u226444 \u043c\u0441. \u0417\u043d\u0430\u0447\u0435\u043d\u0438\u044f 44-48 \u043c\u0441 (110-120%) \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u2014 \u0432\u0435\u0440\u043e\u044f\u0442\u043d\u043e, \u043f\u043e\u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0441\u043c\u0430\u0437\u043a\u0430, \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0430 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0438\u043b\u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430. \u0417\u043d\u0430\u0447\u0435\u043d\u0438\u044f &gt;48 \u043c\u0441 (&gt;120%) \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043d\u0430 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0438\u0437\u043d\u043e\u0441\u0430, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0435\u0433\u043e \u0440\u0435\u043c\u043e\u043d\u0442\u0430 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u044b. \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f = \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f (\u043a\u0430\u0442\u0443\u0448\u043a\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u2192 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0437\u0430\u0449\u0435\u043b\u043a\u0438, 5-15 \u043c\u0441) + \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (\u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0437\u0430\u0449\u0435\u043b\u043a\u0438 \u2192 \u043f\u043e\u043b\u043d\u044b\u0439 \u0445\u043e\u0434, 15-30 \u043c\u0441) + \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0434\u0443\u0433\u0438 (5-10 \u043c\u0441). \u041f\u043e\u043b\u0435\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442, \u0447\u0442\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438, \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f 120%, \u0438\u043c\u0435\u044e\u0442 \u0432 3-5 \u0440\u0430\u0437 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0443\u044e \u0447\u0430\u0441\u0442\u043e\u0442\u0443 \u043e\u0442\u043a\u0430\u0437\u043e\u0432 \u043f\u0440\u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0438\u0437-\u0437\u0430 \u0447\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0434\u0443\u0433\u0438 (&gt;2,5 \u043a\u0414\u0436 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u043f\u0440\u043e\u0435\u043a\u0442\u043d\u044b\u043c \u043f\u0440\u0435\u0434\u0435\u043b\u043e\u043c &lt;2,0 \u043a\u0414\u0436 \u043f\u0440\u0438 25 \u043a\u0410).<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u043a\u0440\u0438\u0432\u0430\u044f \u0445\u043e\u0434\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u0438\u0437\u043d\u043e\u0441 \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430?<\/strong><\/p>\n\n\n\n<p>\u0417\u0434\u043e\u0440\u043e\u0432\u0430\u044f \u043a\u0440\u0438\u0432\u0430\u044f \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f \u0441\u043e\u0441\u0442\u043e\u0438\u0442 \u0438\u0437 \u0442\u0440\u0435\u0445 \u0444\u0430\u0437: (1) \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u0435 (\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0430\u0431\u0438\u0440\u0430\u044e\u0442 \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c, 0-60% \u0445\u043e\u0434\u0430), (2) \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c (\u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u0438\u043a\u043e\u0432\u0430\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c, 60-80% \u0445\u043e\u0434\u0430), (3) \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u0435 (\u0434\u0435\u043c\u043f\u0444\u0435\u0440 \u043f\u043e\u0433\u043b\u043e\u0449\u0430\u0435\u0442 \u044d\u043d\u0435\u0440\u0433\u0438\u044e, 80-100% \u0445\u043e\u0434\u0430). \u0418\u0437\u043d\u043e\u0441 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 \u043f\u0440\u043e\u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0432 \u0432\u0438\u0434\u0435 \u043f\u043e\u0442\u0435\u0440\u0438 \u0444\u0430\u0437\u044b 3 \u2014 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u0443\u044e \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u0434\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u0430, \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u044f \u0440\u0435\u0437\u043a\u0443\u044e \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0443. \u042d\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u044e \u0441\u0438\u043b\u044b \u0443\u0434\u0430\u0440\u0430 \u0432 10-20 \u0440\u0430\u0437 (500-1000 \u041d \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 50-100 \u041d \u0441 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u043e\u043c), \u0443\u0441\u043a\u043e\u0440\u044f\u044f \u0438\u0437\u043d\u043e\u0441 \u043e\u043f\u043e\u0440\u043d\u044b\u0445 \u0448\u0442\u0438\u0444\u0442\u043e\u0432, \u0442\u044f\u0433 \u0438 \u0432\u044b\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432. \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0440\u0438\u0447\u0438\u043d\u044b: \u0443\u0442\u0435\u0447\u043a\u0430 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0438\u0437 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 (\u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0443\u043f\u043b\u043e\u0442\u043d\u0435\u043d\u0438\u044f), \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u044c \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 (\u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0437\u0430\u043c\u0435\u043d\u0430 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438) \u0438\u043b\u0438 \u043e\u0448\u0438\u0431\u043a\u0430 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 (\u043f\u043e\u0440\u0448\u0435\u043d\u044c \u043d\u0435 \u0437\u0430\u0446\u0435\u043f\u043b\u044f\u0435\u0442\u0441\u044f). \u0414\u043b\u044f \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0435\u0440\u0435\u0441\u0442\u0440\u043e\u0438\u0442\u044c \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440 \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0438\u0445 \u0443\u043f\u043b\u043e\u0442\u043d\u0435\u043d\u0438\u0439 \u0438 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438, \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c (\u043e\u0431\u044b\u0447\u043d\u043e \u0441\u0438\u043b\u0438\u043a\u043e\u043d\u043e\u0432\u043e\u0435 \u043c\u0430\u0441\u043b\u043e \u0441 \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u044c\u044e 100-500 cSt). \u041d\u0430\u0448\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f 120 VCB, \u043f\u0440\u043e\u0441\u043b\u0443\u0436\u0438\u0432\u0448\u0438\u0445 10-20 \u043b\u0435\u0442, \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438, \u0447\u0442\u043e 25% \u043d\u0435 \u0438\u043c\u0435\u043b \u0432\u0438\u0434\u0438\u043c\u043e\u0433\u043e \u0437\u0430\u043c\u0435\u0434\u043b\u0435\u043d\u0438\u044f \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041f\u043e\u0447\u0435\u043c\u0443 \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f VCB \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u043d\u0430 10-15% \u043f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f 80%?<\/strong><\/p>\n\n\n\n<p>\u041c\u0430\u0433\u043d\u0438\u0442\u043d\u0430\u044f \u0441\u0438\u043b\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f F \u221d (I_coil)\u00b2 \u221d (V \/ R)\u00b2. \u041f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 80% \u0441\u0438\u043b\u0430 \u043f\u0430\u0434\u0430\u0435\u0442 \u0434\u043e (0,8)\u00b2 = 64% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f. \u0411\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0430\u044f \u0441\u0438\u043b\u0430 \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442 \u0431\u043e\u043b\u0435\u0435 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f (\u0437\u0430\u0449\u0435\u043b\u043a\u0430 \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u0432\u0430\u0435\u0442 \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u043d\u043e\u0435 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0435 \u043f\u0440\u0438\u0442\u044f\u0436\u0435\u043d\u0438\u0435 \u0431\u043e\u043b\u0435\u0435 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e) \u0438 \u043f\u043e\u0442\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0435 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u043a\u043e\u0440\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 70-110% \u0434\u043b\u044f \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0438\u0438 \u043a\u043e\u043b\u0435\u0431\u0430\u043d\u0438\u0439 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u0415\u0441\u043b\u0438 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0447\u0435\u043c \u043d\u0430 20% \u043f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u043e\u0442 110% \u0434\u043e 80%, \u043f\u043e\u0434\u043e\u0437\u0440\u0435\u0432\u0430\u0439\u0442\u0435: (1) \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0432\u044b\u0441\u043e\u043a\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438 (\u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u0435, \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432), (2) \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0437\u0430\u0446\u0435\u043f\u043b\u0435\u043d\u0438\u0435 (\u0442\u0440\u0435\u043d\u0438\u0435 \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u0435\u0442 \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u043d\u0443\u044e \u0441\u0438\u043b\u0443), (3) \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0441\u0438\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u0430 \u0437\u0430\u0449\u0435\u043b\u043a\u0438 (\u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430\u044f \u0441\u0438\u043b\u0430 \u0434\u043b\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f). \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0434\u043e\u043b\u0436\u043d\u043e \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0442\u044c 10-15% \u0432 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439. \u041f\u0440\u043e\u0432\u0435\u0434\u0438\u0442\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435, \u0438\u0437\u043c\u0435\u0440\u0438\u0432 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 70%, 80%, 100%, 110%; \u043d\u0435\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 70% \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e, \u043d\u043e \u043d\u0435\u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u0438 80-110% \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0438\u043b\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0438\u0437\u043d\u0430\u0448\u0438\u0432\u0430\u043d\u0438\u0435.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 4: \u0427\u0442\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u043e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u043f\u0440\u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u0438 \u0438 \u043f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0438\u043c\u0435\u0435\u0442 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435?<\/strong><\/p>\n\n\n\n<p>\u041e\u0442\u0441\u043a\u043e\u043a \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u043f\u0440\u043e\u0438\u0441\u0445\u043e\u0434\u0438\u0442, \u043a\u043e\u0433\u0434\u0430 \u043a\u0438\u043d\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u044f \u0434\u0432\u0438\u0436\u0443\u0449\u0435\u0433\u043e\u0441\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u0443\u044e\u0449\u0443\u044e \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u0443\u0436\u0438\u043d\u044b\/\u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430. \u041f\u0440\u0438 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u043c \u0441\u043e\u043f\u0440\u0438\u043a\u043e\u0441\u043d\u043e\u0432\u0435\u043d\u0438\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u043d\u0430 \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u044f\u044e\u0442\u0441\u044f (\u043d\u0430 0,1\u20130,5 \u043c\u043c, \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c\u044e 1\u20133 \u043c\u0441) \u043f\u0435\u0440\u0435\u0434 \u0442\u0435\u043c, \u043a\u0430\u043a \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u0442\u044c\u0441\u044f. \u0412\u043e \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u0441\u043a\u043e\u043a\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0432\u043d\u043e\u0432\u044c \u0440\u0430\u0437\u043c\u044b\u043a\u0430\u044e\u0442\u0441\u044f, \u043f\u043e\u043a\u0430 \u043f\u0440\u043e\u0442\u0435\u043a\u0430\u0435\u0442 \u0442\u043e\u043a \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u2192 \u0441\u043e\u0437\u0434\u0430\u0435\u0442\u0441\u044f \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0434\u0443\u0433\u0430, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u0441\u0432\u0430\u0440\u0438\u0432\u0430\u0435\u0442 \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0434\u043e \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u043b\u043d\u043e\u0433\u043e \u0441\u0436\u0430\u0442\u0438\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u044b. \u042d\u0442\u043e \u0441\u043d\u0438\u0436\u0430\u0435\u0442 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430, \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u0432\u0430\u0435\u0442 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438 \u0443\u0441\u043a\u043e\u0440\u044f\u0435\u0442 \u044d\u0440\u043e\u0437\u0438\u044e. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 IEC 62271-100 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0435\u0442 \u043e\u0442\u0441\u043a\u043e\u043a \u0434\u043e &lt;0,3 \u043c\u043c; \u043b\u0443\u0447\u0448\u0430\u044f \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0430 \u2014 10 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439). \u041f\u0440\u0438\u0447\u0438\u043d\u044b: \u0438\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u0430\u044f \u0441\u0438\u043b\u0430 \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u044e\u0449\u0435\u0439 \u043f\u0440\u0443\u0436\u0438\u043d\u044b (\u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0431\u043e\u043b\u044c\u0448\u0430\u044f \u043a\u0438\u043d\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u044f), \u043d\u0435\u0430\u0434\u0435\u043a\u0432\u0430\u0442\u043d\u043e\u0435 \u0434\u0435\u043c\u043f\u0444\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0430 (\u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u044c \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438) \u0438\u043b\u0438 \u043d\u0435\u0440\u043e\u0432\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 (\u043f\u0438\u0442\u0442\u0438\u043d\u0433 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043d\u0435\u0440\u0430\u0432\u043d\u043e\u043c\u0435\u0440\u043d\u043e\u0435 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u0438\u043a\u043e\u0441\u043d\u043e\u0432\u0435\u043d\u0438\u0435). \u0418\u0437\u043c\u0435\u0440\u044f\u0439\u0442\u0435 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043a\u0440\u0438\u0432\u043e\u0439 \u0445\u043e\u0434\u0430 \u0441 \u0432\u044b\u0441\u043e\u043a\u0438\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435\u043c (\u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0434\u0438\u0441\u043a\u0440\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u226510 \u043a\u0413\u0446); \u043d\u0430\u0431\u043b\u044e\u0434\u0430\u0439\u0442\u0435 \u0437\u0430 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 \u043f\u0435\u0440\u0432\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430. \u0418\u0441\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435: \u043e\u0442\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0439\u0442\u0435 \u043f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u0442\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f, \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u044c \u0434\u0435\u043c\u043f\u0444\u0435\u0440\u0430 \u0438\u043b\u0438 \u043e\u0442\u0448\u043b\u0438\u0444\u0443\u0439\u0442\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 5: \u041a\u0430\u043a \u0447\u0430\u0441\u0442\u043e \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0445\u043e\u0434\u0430 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b VCB?<\/strong><\/p>\n\n\n\n<p>\u0421\u043e\u0431\u043b\u044e\u0434\u0430\u0439\u0442\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b, \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u043e\u0431\u044f\u0437\u0430\u043d\u043d\u043e\u0441\u0442\u044f\u0445: (1)&nbsp;<strong>\u0412\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/strong>&nbsp;\u2013 \u043f\u043e\u043b\u043d\u044b\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0438 \u043a\u0440\u0438\u0432\u043e\u0439 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u0431\u0430\u0437\u043e\u0432\u044b\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0435\u0439; (2)&nbsp;<strong>\u0415\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0439 (0-5 \u043b\u0435\u0442)<\/strong>&nbsp;\u2013 \u0442\u043e\u043b\u044c\u043a\u043e \u0431\u044b\u0441\u0442\u0440\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f; (3)&nbsp;<strong>\u0414\u0432\u0443\u0445\u0433\u043e\u0434\u0438\u0447\u043d\u044b\u0439 (6\u201315 \u043b\u0435\u0442)<\/strong>&nbsp;\u2013 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f\/\u0437\u0430\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u043b\u044e\u0441 \u043a\u0440\u0438\u0432\u044b\u0435 \u0434\u0432\u0438\u0436\u0435\u043d\u0438\u044f; (4)&nbsp;<strong>\u0415\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0439 (&gt;15 \u043b\u0435\u0442 \u0438\u043b\u0438 \u0438\u043d\u0442\u0435\u043d\u0441\u0438\u0432\u043d\u0430\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f &gt;1000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439\/\u0433\u043e\u0434)<\/strong>&nbsp;\u2013 \u043f\u043e\u043b\u043d\u044b\u0439 \u0430\u043d\u0430\u043b\u0438\u0437, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c \u043a 10 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u043c. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b IEC 62271-100 \u0438 IEEE C37.09 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u044e\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 2000\u20135000 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0447\u0442\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 10\u201315 \u0433\u043e\u0434\u0430\u043c \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438). \u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0440\u0435\u043b\u0435 \u0441 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435\u043c \u0432\u0440\u0435\u043c\u0435\u043d\u0438 (SEL-487V, ABB REM615) \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u0430\u043d\u0430\u043b\u0438\u0437 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0439 \u0432 \u0440\u0435\u0436\u0438\u043c\u0435 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u0430\u043d\u0430\u043b\u0438\u0437\u0438\u0440\u0443\u044f \u043a\u0430\u0436\u0434\u0443\u044e \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044e, \u0430 \u043d\u0435 \u0435\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0435 \u043c\u043e\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u044b\u0435 \u0441\u043d\u0438\u043c\u043a\u0438. \u041d\u0430\u0448\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u043a\u0430\u0437\u0430\u043b\u0438, \u0447\u0442\u043e \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0432\u0430\u0435\u0442 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0438 \u043a \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u044e \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0437\u0430 12\u201318 \u043c\u0435\u0441\u044f\u0446\u0435\u0432 \u0434\u043e \u0435\u0436\u0435\u0433\u043e\u0434\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0447\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0442\u044c \u043f\u0440\u043e\u0444\u0438\u043b\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0440\u0435\u043c\u043e\u043d\u0442 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u043b\u0430\u043d\u043e\u0432\u044b\u0445 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439, \u0430 \u043d\u0435 \u044d\u043a\u0441\u0442\u0440\u0435\u043d\u043d\u0443\u044e \u0437\u0430\u043c\u0435\u043d\u0443.<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 6: \u041c\u043e\u0433\u0443\u0442 \u043b\u0438 \u0442\u0435\u0441\u0442\u044b \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u0438 VCB \u043f\u0440\u0435\u0434\u0441\u043a\u0430\u0437\u0430\u0442\u044c, \u043a\u043e\u0433\u0434\u0430 \u043f\u043e\u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0437\u0430\u043c\u0435\u043d\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432?<\/strong><\/p>\n\n\n\n<p>\u041a\u043e\u0441\u0432\u0435\u043d\u043d\u043e \u0434\u0430 \u2014 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043a\u043e\u0440\u0440\u0435\u043b\u0438\u0440\u0443\u0435\u0442 \u0441 \u0438\u0437\u043d\u043e\u0441\u043e\u043c \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u0431\u0430 \u044f\u0432\u043b\u0435\u043d\u0438\u044f \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u043e\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0437\u043d\u043e\u0441\u0430. \u041f\u043e \u043c\u0435\u0440\u0435 \u0438\u0437\u043d\u043e\u0441\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438\u0437\u043c\u0435\u043d\u044f\u0435\u0442\u0441\u044f \u0445\u043e\u0434 (\u043f\u043e\u0434\u0432\u0438\u0436\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0434\u043e\u043b\u0436\u0435\u043d \u043f\u0440\u043e\u0439\u0442\u0438 \u0431\u043e\u043b\u044c\u0448\u0435\u0435 \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435, \u0447\u0442\u043e\u0431\u044b \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u043e\u0442\u0434\u0435\u043b\u0438\u0442\u044c\u0441\u044f), \u0430 \u0443\u0441\u0438\u043b\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u043c\u043e\u0436\u0435\u0442 \u043e\u0441\u043b\u0430\u0431\u0435\u0432\u0430\u0442\u044c \u0438\u0437-\u0437\u0430 \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u0423\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043d\u0430 10-20% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0431\u0430\u0437\u043e\u0432\u044b\u043c \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0435\u043c \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u0430\u0433\u0430\u0435\u0442 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043d\u0430 \u0438\u0437\u043d\u043e\u0441 &gt;30% \u043e\u0442 \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u043e\u0439 \u0442\u043e\u043b\u0449\u0438\u043d\u044b \u0438\u043b\u0438 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 &gt;500 \u043c\u043a\u041e\u043c. \u0414\u043b\u044f \u043f\u0440\u044f\u043c\u043e\u0439 \u043e\u0446\u0435\u043d\u043a\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 (\u043c\u0438\u043a\u0440\u043e\u043e\u043c\u043c\u0435\u0442\u0440\u043e\u043c), \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440 \u043d\u0430 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u043f\u0438\u0442\u0442\u0438\u043d\u0433\u0430\/\u044d\u0440\u043e\u0437\u0438\u0438 \u0438\u043b\u0438 \u0440\u0435\u043d\u0442\u0433\u0435\u043d\u043e\u0432\u0441\u043a\u0438\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 (\u043d\u0435\u0438\u043d\u0432\u0430\u0437\u0438\u0432\u043d\u044b\u0439). \u041e\u0434\u043d\u0430\u043a\u043e \u0430\u043d\u0430\u043b\u0438\u0437 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0439 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0434\u0430\u0435\u0442 \u0440\u0430\u043d\u043d\u0435\u0435 \u043f\u0440\u0435\u0434\u0443\u043f\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435: \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c, \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043a\u043e\u0442\u043e\u0440\u043e\u0433\u043e \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u043b\u043e\u0441\u044c \u043d\u0430 1-2 \u043c\u0441\/\u0433\u043e\u0434 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 3 \u043b\u0435\u0442 \u043f\u043e\u0434\u0440\u044f\u0434, \u0432\u0435\u0440\u043e\u044f\u0442\u043d\u043e, \u043f\u043e\u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0437\u0430\u043c\u0435\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 2-3 \u043b\u0435\u0442. \u041a\u043e\u043c\u0431\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0439 (\u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f + \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 + \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439) \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043f\u0440\u0435\u0434\u0441\u043a\u0430\u0437\u0430\u0442\u044c \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u0440\u0435\u043c\u043e\u043d\u0442\u0430 \u0441 \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c\u044e 85-90% \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0430\u043d\u0430\u043b\u0438\u0437\u043e\u043c \u0442\u043e\u043b\u044c\u043a\u043e \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439 (\u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c 60-70%).<\/p>\n\n\n\n<p><strong>\u0412\u043e\u043f\u0440\u043e\u0441 7: \u041a\u0430\u043a\u0438\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u043d\u044f\u0442\u044c, \u0435\u0441\u043b\u0438 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043d\u0430 25% \u043c\u0435\u043d\u044c\u0448\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e?<\/strong><\/p>\n\n\n\n<p>\u0421\u043b\u0435\u0434\u0443\u0439\u0442\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0434\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u0435: (1)&nbsp;<strong>\u041f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435<\/strong>&nbsp;\u2013 \u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u043a\u0443 \u0434\u0430\u0442\u0447\u0438\u043a\u0430 \u043f\u0435\u0440\u0435\u043c\u0435\u0449\u0435\u043d\u0438\u044f, \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c, \u0447\u0442\u043e \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0434\u0430\u043d\u043d\u044b\u043c \u0434\u0430\u0442\u0447\u0438\u043a\u0430 (\u00b15 \u043c\u0441); (2)&nbsp;<strong>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong>&nbsp;\u2013 \u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 80%, 100%, 110%; \u0435\u0441\u043b\u0438 \u0432\u0441\u0435 \u0442\u0440\u0438 \u043f\u0440\u043e\u043f\u043e\u0440\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u044b\u0435, \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f (\u0441\u043b\u0430\u0431\u044b\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b, \u0442\u0440\u0435\u043d\u0438\u0435); \u0435\u0441\u043b\u0438 \u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u043d\u0438\u0437\u043a\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435, \u043f\u043e\u0434\u043e\u0437\u0440\u0435\u0432\u0430\u0439\u0442\u0435 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0443 \u0441 \u043a\u0430\u0442\u0443\u0448\u043a\u043e\u0439\/\u0437\u0430\u0449\u0435\u043b\u043a\u043e\u0439; (3)&nbsp;<strong>\u0420\u0443\u0447\u043d\u043e\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435<\/strong>&nbsp;\u2013 \u0412\u0440\u0443\u0447\u043d\u0443\u044e \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435 \u0446\u0435\u043f\u044c, \u043f\u043e\u0447\u0443\u0432\u0441\u0442\u0432\u0443\u0439\u0442\u0435, \u043d\u0435\u0442 \u043b\u0438 \u0437\u0430\u043a\u043b\u0438\u043d\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f; (4)&nbsp;<strong>\u0412\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0439 \u043e\u0441\u043c\u043e\u0442\u0440<\/strong>&nbsp;\u2013 \u0421\u043d\u0438\u043c\u0438\u0442\u0435 \u043a\u0440\u044b\u0448\u043a\u0443 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430, \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435, \u043d\u0435\u0442 \u043b\u0438 \u0441\u043b\u043e\u043c\u0430\u043d\u043d\u044b\u0445 \u043f\u0440\u0443\u0436\u0438\u043d, \u0443\u0442\u0435\u0447\u0435\u043a \u0432 \u0430\u043c\u043e\u0440\u0442\u0438\u0437\u0430\u0442\u043e\u0440\u0435, \u0438\u0437\u043d\u043e\u0448\u0435\u043d\u043d\u044b\u0445 \u043e\u043f\u043e\u0440\u043d\u044b\u0445 \u0448\u0442\u0438\u0444\u0442\u043e\u0432; (5)&nbsp;<strong>\u0421\u043c\u0430\u0437\u043a\u0430<\/strong>&nbsp;\u2013 \u041e\u0447\u0438\u0441\u0442\u0438\u0442\u0435 \u0438 \u0441\u043c\u0430\u0436\u044c\u0442\u0435 \u0432\u0441\u0435 \u0448\u0430\u0440\u043d\u0438\u0440\u044b \u0441\u043c\u0430\u0437\u043a\u043e\u0439, \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c (\u043e\u0431\u044b\u0447\u043d\u043e \u044d\u0442\u043e \u0441\u043c\u0430\u0437\u043a\u0430 MoS\u2082); (6)&nbsp;<strong>\u041d\u0430\u0442\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b<\/strong>&nbsp;\u2013 \u0418\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0443\u0441\u0438\u043b\u0438\u0435 \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f \u043f\u0440\u0443\u0436\u0438\u043d\u044b \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0440\u0438\u0431\u043e\u0440\u0430 (\u043e\u043d\u043e \u0434\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u00b110% \u043e\u0442 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f, \u0443\u043a\u0430\u0437\u0430\u043d\u043d\u043e\u0433\u043e \u0432 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u0435). \u0415\u0441\u043b\u0438 \u0441\u043c\u0430\u0437\u043a\u0430 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044e \u0434\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f &lt;110%, \u0432\u0435\u0440\u043d\u0438\u0442\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0441 \u0443\u0441\u0438\u043b\u0435\u043d\u043d\u044b\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c. \u0415\u0441\u043b\u0438 \u043f\u043e\u0441\u043b\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 110%, \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u044b\/\u0434\u0435\u043c\u043f\u0444\u0435\u0440. \u0415\u0441\u043b\u0438 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 125% \u0438\u043b\u0438 \u043f\u0440\u043e\u0438\u0437\u043e\u0448\u0435\u043b \u043e\u0442\u043a\u0430\u0437 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u0445 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432, \u0437\u0430\u043f\u043b\u0430\u043d\u0438\u0440\u0443\u0439\u0442\u0435 \u043f\u043e\u043b\u043d\u0443\u044e \u0440\u0435\u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044e \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0443.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum circuit breaker (VCB) timing tests measure the mechanical response during opening and closing operations\u2014how fast contacts move, whether motion is smooth, and if performance matches manufacturer specifications. These tests verify that the breaker can interrupt fault current before damage occurs, that mechanical wear hasn\u2019t degraded performance, and that protection coordination assumptions remain valid. A [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2429,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=2425"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2425\/revisions"}],"predecessor-version":[{"id":3569,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/2425\/revisions\/3569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/2429"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=2425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=2425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=2425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}