{"id":3685,"date":"2026-04-13T05:30:45","date_gmt":"2026-04-13T05:30:45","guid":{"rendered":"https:\/\/xbrele.com\/?p=3685"},"modified":"2026-05-25T14:29:00","modified_gmt":"2026-05-25T14:29:00","slug":"relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter\/","title":{"rendered":"\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u0430\u0440\u0442\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u043f\u0430\u043d\u0435\u043b\u0435\u0439 MV: 50\/51\/50N\/51N\/27\/59\/86 - \u041a\u0430\u043a \u043e\u043d\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0442\u0441\u044f"},"content":{"rendered":"<h2>\u0418\u0441\u0447\u0435\u0440\u043f\u044b\u0432\u0430\u044e\u0449\u0435\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 \u0438 \u0441\u0445\u0435\u043c\u0430\u043c \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/h2>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3681\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01.webp\" alt=\"\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0445\u0435\u043c\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0430\u043d\u0435\u043b\u0438 MV\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435<\/h2>\n<p>\u0412 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (\u0421\u041d) \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0435 \u0440\u0435\u043b\u0435 \u0441\u043b\u0443\u0436\u0430\u0442 \u0432\u0430\u0436\u043d\u0435\u0439\u0448\u0435\u0439 \u043f\u0435\u0440\u0432\u043e\u0439 \u043b\u0438\u043d\u0438\u0435\u0439 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439, \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b\u0430. \u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u0442\u043e\u0433\u043e, \u043a\u0430\u043a \u044d\u0442\u0438 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0442\u0441\u044f \u0438 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0442 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043a\u0430\u0440\u0442 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f, \u0438\u043c\u0435\u0435\u0442 \u0444\u0443\u043d\u0434\u0430\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f, \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c.<\/p>\n<p>\u0417\u0430 18 \u043b\u0435\u0442 \u0440\u0430\u0431\u043e\u0442\u044b \u043f\u043e \u0432\u0432\u043e\u0434\u0443 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0430 \u043d\u0435\u0444\u0442\u0435\u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0437\u0430\u0432\u043e\u0434\u0430\u0445, \u0432 \u0446\u0435\u043d\u0442\u0440\u0430\u0445 \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u0445 \u0438 \u043d\u0430 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u044f\u0445 \u044f \u043d\u0430 \u0441\u043e\u0431\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u043c \u043e\u043f\u044b\u0442\u0435 \u0443\u0431\u0435\u0434\u0438\u043b\u0441\u044f, \u0447\u0442\u043e \u043f\u043b\u043e\u0445\u043e \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0441\u0445\u0435\u043c\u044b \u0440\u0435\u043b\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u0440\u0438\u0432\u0435\u0441\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u0441\u0442\u0440\u043e\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043e\u0442\u043a\u0430\u0437\u0430\u043c. \u0418 \u043d\u0430\u043e\u0431\u043e\u0440\u043e\u0442, \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u044b\u0435 \u043a\u0430\u0440\u0442\u044b \u043b\u043e\u0433\u0438\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u043b\u0438 \u0441\u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0442\u044c \u043c\u0438\u043b\u043b\u0438\u043e\u043d\u044b \u0434\u043e\u043b\u043b\u0430\u0440\u043e\u0432 \u043d\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0438 \u0438, \u0447\u0442\u043e \u0435\u0449\u0435 \u0432\u0430\u0436\u043d\u0435\u0435, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0442\u0438\u0442\u044c \u0442\u0440\u0430\u0432\u043c\u044b.<\/p>\n<p>\u0412 \u044d\u0442\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u043e \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 - \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 ANSI \u043f\u043e\u0434 \u043d\u043e\u043c\u0435\u0440\u0430\u043c\u0438 50, 51, 50N, 51N, 27, 59 \u0438 86 - \u0438 \u043e\u0431\u044a\u044f\u0441\u043d\u044f\u0435\u0442\u0441\u044f, \u043a\u0430\u043a \u043e\u043d\u0438 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0442 \u0432 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u0435 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 MV. \u041d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e \u043e\u0442 \u0442\u043e\u0433\u043e, \u044f\u0432\u043b\u044f\u0435\u0442\u0435\u0441\u044c \u043b\u0438 \u0432\u044b \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043e\u043c \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435, \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u0443\u044e\u0449\u0438\u043c \u043d\u043e\u0432\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u0438\u043b\u0438 \u0442\u0435\u0445\u043d\u0438\u043a\u043e\u043c, \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u044e\u0449\u0438\u043c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0432 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430\u0445, \u044d\u0442\u043e \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e\u0441\u043b\u0443\u0436\u0438\u0442 \u0432\u0430\u043c \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0441\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u0438\u043a\u043e\u043c \u0434\u043b\u044f \u043f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u043b\u043e\u0433\u0438\u043a\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3682\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02.webp\" alt=\"\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0445\u0435\u043c\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0430\u043d\u0435\u043b\u0438 MV\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 1: \u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043d\u043e\u043c\u0435\u0440\u043e\u0432 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 ANSI \u0438 \u0438\u0445 \u0444\u0443\u043d\u043a\u0446\u0438\u0439<\/h2>\n<p>\u041f\u0440\u0435\u0436\u0434\u0435 \u0447\u0435\u043c \u043f\u0435\u0440\u0435\u0439\u0442\u0438 \u043a \u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u0438\u044e \u0441\u0445\u0435\u043c \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u0447\u0435\u0442\u043a\u043e\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u043e \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u0445 \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0440\u0435\u043b\u0435. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 ANSI\/IEEE C37.2 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u043d\u043e\u043c\u0435\u0440\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u0442\u0430\u043b\u0438 \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u044b\u043c \u044f\u0437\u044b\u043a\u043e\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b.<\/p>\n<h3>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443 (50\/51)<\/h3>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 50 (\u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u0430\u044f \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443)<\/strong> \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u0442 \u0431\u0435\u0437 \u043f\u0440\u0435\u0434\u043d\u0430\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0439 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438, \u043a\u043e\u0433\u0434\u0430 \u0442\u043e\u043a \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0435\u0442 \u0437\u0430\u0434\u0430\u043d\u043d\u044b\u0439 \u043f\u043e\u0440\u043e\u0433. \u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u043e\u0442 6 \u0434\u043e 10 \u0440\u0430\u0437 \u0431\u043e\u043b\u044c\u0448\u0435 \u0442\u043e\u043a\u0430 \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432 \u0438 \u043e\u0442 1,5 \u0434\u043e 2 \u0440\u0430\u0437 \u0434\u043b\u044f \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0435\u0439. \u042d\u043b\u0435\u043c\u0435\u043d\u0442 \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0441\u043a\u043e\u0440\u043e\u0441\u0442\u043d\u043e\u0435 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u043f\u0440\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\u0445 \u0432\u0431\u043b\u0438\u0437\u0438, \u0433\u0434\u0435 \u0432\u0435\u0440\u043e\u044f\u0442\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430.<\/p>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 51 (\u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438)<\/strong> \u0432\u0432\u043e\u0434\u0438\u0442 \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0443\u044e \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0443 \u0432\u0440\u0435\u043c\u044f-\u0442\u043e\u043a, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c \u043d\u0438\u0436\u0435\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u0442\u044c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0434\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0432\u044b\u0448\u0435\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f. \u042d\u0442\u0430 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0434\u043e\u0441\u0442\u0438\u0433\u0430\u0435\u0442\u0441\u044f \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043a\u0440\u0438\u0432\u044b\u0445 (IEC \u0447\u0440\u0435\u0437\u0432\u044b\u0447\u0430\u0439\u043d\u043e \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0430\u044f, \u043e\u0447\u0435\u043d\u044c \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0430\u044f, \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u0430\u044f \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0430\u044f \u0438\u043b\u0438 IEEE \u0443\u043c\u0435\u0440\u0435\u043d\u043d\u043e \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0430\u044f, \u043e\u0447\u0435\u043d\u044c \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0430\u044f, \u0447\u0440\u0435\u0437\u0432\u044b\u0447\u0430\u0439\u043d\u043e \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u0430\u044f).<\/p>\n<h3>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e (50N\/51N)<\/h3>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 50N (\u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u0430\u044f \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f)<\/strong> \u041e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0432\u0430\u0435\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u043f\u0443\u0442\u0435\u043c \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u0412 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441\u043e \u0441\u043f\u043b\u043e\u0448\u043d\u044b\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435\u043c \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043d\u0430\u0432\u043e\u0434\u043a\u0438 \u043e\u0431\u044b\u0447\u043d\u043e \u043d\u0430\u0445\u043e\u0434\u044f\u0442\u0441\u044f \u0432 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 10-20% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u0430 \u0444\u0430\u0437\u043d\u043e\u0433\u043e \u0422\u0422. \u0412 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441 \u0440\u0435\u0437\u0438\u0441\u0442\u0438\u0432\u043d\u044b\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435\u043c \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u044b \u0441 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u043d\u044b\u043c \u0442\u043e\u043a\u043e\u043c \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u0430 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f \u043d\u0435\u0439\u0442\u0440\u0430\u043b\u0438.<\/p>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 51N (\u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0435 \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438)<\/strong> \u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0437\u0430\u0449\u0438\u0442\u0443 \u043e\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439 \u043d\u0430 \u0437\u0435\u043c\u043b\u044e, \u0447\u0442\u043e \u043e\u0447\u0435\u043d\u044c \u0432\u0430\u0436\u043d\u043e \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445, \u0433\u0434\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u0430\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043c\u0435\u0436\u0434\u0443 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439 \u043d\u0430 \u0437\u0435\u043c\u043b\u044e.<\/p>\n<h3>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u0435\u0440\u0435\u043f\u0430\u0434\u043e\u0432 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (27\/59)<\/h3>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 27 (\u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435)<\/strong> \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043e\u0442 \u043f\u0440\u043e\u0441\u0430\u0434\u043e\u043a \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u043f\u0440\u043e\u043f\u0430\u0434\u0430\u043d\u0438\u044f \u043f\u0438\u0442\u0430\u043d\u0438\u044f, \u043e\u0431\u044b\u0447\u043d\u043e \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0432 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 80-90% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0441 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 1-10 \u0441\u0435\u043a\u0443\u043d\u0434 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f. \u042d\u0442\u0430 \u0444\u0443\u043d\u043a\u0446\u0438\u044f \u0432\u0430\u0436\u043d\u0430 \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0437\u0430\u043f\u0443\u0441\u043a\u0430 \u043f\u0440\u0438 \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u0438 \u0443\u0441\u043b\u043e\u0432\u0438\u0439.<\/p>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 59 (\u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435)<\/strong> \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043e\u0442 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0434\u0438\u0442\u044c \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e \u0438 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435. \u041e\u0431\u044b\u0447\u043d\u043e \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043d\u0430\u0445\u043e\u0434\u044f\u0442\u0441\u044f \u0432 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 110-120% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n<h3>\u0420\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 (86)<\/h3>\n<p><strong>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 86 (\u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438)<\/strong> \u044d\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0441 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043f\u0440\u0438\u0432\u043e\u0434\u043e\u043c \u0438 \u0440\u0443\u0447\u043d\u044b\u043c \u0441\u0431\u0440\u043e\u0441\u043e\u043c, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0443\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u0432 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u043d\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438 \u0434\u043e \u0442\u0435\u0445 \u043f\u043e\u0440, \u043f\u043e\u043a\u0430 \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440 \u0432\u0440\u0443\u0447\u043d\u0443\u044e \u043d\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438. \u042d\u0442\u0430 \u0444\u0443\u043d\u043a\u0446\u0438\u044f \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043e\u0441\u043d\u043e\u0432\u043e\u043f\u043e\u043b\u0430\u0433\u0430\u044e\u0449\u0435\u0439 \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u044b\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c.<\/p>\n<hr \/>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e ANSI<\/th>\n<th>\u0417\u0430\u0449\u0438\u0442\u043d\u0430\u044f \u0440\u043e\u043b\u044c<\/th>\n<th>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0439 \u043c\u0430\u0440\u0448\u0440\u0443\u0442 \u043f\u0443\u0442\u0435\u0448\u0435\u0441\u0442\u0432\u0438\u044f<\/th>\n<th>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>50 \/ 51<\/td>\n<td>\u041c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u0430\u044f \u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0437\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u0441\u0432\u0435\u0440\u0445\u0442\u043e\u043a\u043e\u0432<\/td>\n<td>\u0420\u0435\u043b\u0435\u0439\u043d\u044b\u0439 \u0432\u044b\u0445\u043e\u0434 \u043d\u0430 \u043a\u0430\u0442\u0443\u0448\u043a\u0443 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u0438\u043b\u0438 86 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/td>\n<td>\u0418\u043d\u0436\u0435\u043a\u0446\u0438\u044f \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043f\u0440\u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430\u0445 \u043f\u0438\u043a\u0430\u043f\u0430 \u0438 \u0442\u0430\u0439\u043c\u0435\u0440\u0430<\/td>\n<\/tr>\n<tr>\n<td>50N \/ 51N<\/td>\n<td>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439 \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438\u043b\u0438 \u0442\u043e\u043a\u0430 \u043d\u0435\u0439\u0442\u0440\u0430\u043b\u0438<\/td>\n<td>\u041e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u043e \u043d\u0430 \u0444\u0438\u0434\u0435\u0440\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0438 \u0446\u0435\u043f\u044c \u0441\u0438\u0433\u043d\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438<\/td>\n<td>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043f\u043e\u043b\u044f\u0440\u043d\u043e\u0441\u0442\u0438 \u0422\u0422, \u0441\u0443\u043c\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043e\u0441\u0442\u0430\u0442\u043a\u043e\u0432 \u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0442\u043e\u043a\u0430 \u042f\u0413\u0420<\/td>\n<\/tr>\n<tr>\n<td>27 \/ 59<\/td>\n<td>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u0433\u043e \u0438 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/td>\n<td>\u041b\u043e\u0433\u0438\u043a\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u0441\u0438\u0433\u043d\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0438\u043b\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/td>\n<td>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0438\u043d\u0436\u0435\u043a\u0446\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 \u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0449\u0435\u0439 \u043b\u043e\u0433\u0438\u043a\u0438<\/td>\n<\/tr>\n<tr>\n<td>86<\/td>\n<td>\u0411\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0441 \u0440\u0443\u0447\u043d\u044b\u043c \u0441\u0431\u0440\u043e\u0441\u043e\u043c \u043f\u043e\u0441\u043b\u0435 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/td>\n<td>\u0411\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0446\u0435\u043f\u0438 \u0434\u043e \u0441\u0431\u0440\u043e\u0441\u0430 \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u043e\u043c<\/td>\n<td>\u0424\u0438\u043a\u0441\u0430\u0442\u043e\u0440 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f, \u0438\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u044f \u0446\u0435\u043b\u0438, \u0437\u0430\u043c\u044b\u043a\u0430\u044e\u0449\u0438\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0438 \u0442\u0435\u0441\u0442 \u043d\u0430 \u0441\u0431\u0440\u043e\u0441<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3683\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03.webp\" alt=\"\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0445\u0435\u043c\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0430\u043d\u0435\u043b\u0438 MV\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 2: \u0410\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u0430 \u043b\u043e\u0433\u0438\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432 \u043f\u0430\u043d\u0435\u043b\u044f\u0445 MV<\/h2>\n<p>\u041a\u0430\u0440\u0442\u0430 \u043b\u043e\u0433\u0438\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442, \u043a\u0430\u043a \u0432\u044b\u0445\u043e\u0434\u044b \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u043a \u043a\u0430\u0442\u0443\u0448\u043a\u0430\u043c \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439, \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c. \u0412 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u044f\u0445 MV \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u0442\u0440\u0438 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f:<\/p>\n<h3>\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f \u043f\u0440\u044f\u043c\u043e\u0439 \u043f\u043e\u0435\u0437\u0434\u043a\u0438<\/h3>\n<p>\u0412 \u043f\u0440\u043e\u0441\u0442\u044b\u0445 \u0441\u043b\u0443\u0447\u0430\u044f\u0445 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0435\u043b\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u043d\u0435\u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u043a \u043a\u0430\u0442\u0443\u0448\u043a\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f. \u041d\u0435\u0441\u043c\u043e\u0442\u0440\u044f \u043d\u0430 \u044d\u043a\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u043e\u0441\u0442\u044c, \u0442\u0430\u043a\u043e\u0439 \u043f\u043e\u0434\u0445\u043e\u0434 \u043b\u0438\u0448\u0435\u043d \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432 \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0438\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0438 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0434\u043b\u044f \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f.<\/p>\n<h3>\u041e\u043f\u043e\u0441\u0440\u0435\u0434\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/h3>\n<p>\u0412 \u0431\u043e\u043b\u0435\u0435 \u0441\u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0445\u0435\u043c\u0430\u0445 \u0432\u0441\u0435 \u0432\u044b\u0445\u043e\u0434\u044b \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0447\u0435\u0440\u0435\u0437 86 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438. \u0422\u0430\u043a\u0430\u044f \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u0435\u0435\u0442 \u0440\u044f\u0434 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432:<\/p>\n<ul>\n<li>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432 \u043e\u0434\u043d\u043e\u0439 \u0442\u043e\u0447\u043a\u0435<\/li>\n<li>\u0418\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u044f \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0444\u043b\u0430\u0433\u0430<\/li>\n<li>\u0412\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u0439 \u0431\u043b\u043e\u043a \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0437\u0430\u043a\u0440\u044b\u0432\u0430\u043d\u0438\u044f<\/li>\n<li>\u041e\u0447\u0438\u0441\u0442\u043a\u0430 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430 \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u0430 \u0434\u043b\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438<\/li>\n<\/ul>\n<h3>\u0412\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u044f\u044f \u043b\u043e\u0433\u0438\u043a\u0430 \u043c\u043d\u043e\u0433\u043e\u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0440\u0435\u043b\u0435<\/h3>\n<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0435 \u0440\u0435\u043b\u0435 \u0440\u0435\u0430\u043b\u0438\u0437\u0443\u044e\u0442 \u043b\u043e\u0433\u0438\u043a\u0443 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432\u043d\u0443\u0442\u0440\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u0435\u043d\u0442\u0438\u043b\u0435\u0439. \u0412\u044b\u0445\u043e\u0434\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0435\u043b\u0435 \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u0441\u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u044b \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u043e\u0432 \u0437\u0430\u0449\u0438\u0442\u044b \u0438\u043b\u0438 \u043a\u043e\u043c\u0431\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0444\u0443\u043d\u043a\u0446\u0438\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3684\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04.webp\" alt=\"\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0445\u0435\u043c\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0430\u043d\u0435\u043b\u0438 MV\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 3: \u0421\u0445\u0435\u043c\u044b \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043c\u0435\u0436\u0434\u0443 \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u0437\u0430\u0449\u0438\u0442\u044b<\/h2>\n<p>\u0412\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u0437\u0430\u0449\u0438\u0442\u043d\u044b\u043c\u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u043e\u0441\u0443\u0449\u0435\u0441\u0442\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u043c\u0438 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u0430\u043c\u0438, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0449\u0438\u043c\u0438 \u043a\u0430\u043a \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c (\u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438), \u0442\u0430\u043a \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c (\u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439).<\/p>\n<h3>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443 \u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e<\/h3>\n<p>\u0424\u0443\u043d\u043a\u0446\u0438\u0438 50\/51 \u0438 50N\/51N \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u044b \u043f\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u0432\u0435\u043b\u0438\u0447\u0438\u043d\u0435. \u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u043c \u0442\u0438\u043f\u0438\u0447\u043d\u0443\u044e \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044e:<\/p>\n<p>\u0414\u043b\u044f \u0444\u0438\u0434\u0435\u0440\u0430 2000A MV \u0441 \u0422\u0422 2000:5:<br \/>\n- 51 \u043f\u0438\u043a\u0430\u043f: 1,2 \u00d7 FLA = 2400A (\u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0430\u044f \u043e\u0431\u043c\u043e\u0442\u043a\u0430 6A)<br \/>\n- 51 \u0446\u0438\u0444\u0435\u0440\u0431\u043b\u0430\u0442 \u0432\u0440\u0435\u043c\u0435\u043d\u0438: 0,5 \u043f\u043e \u043e\u0447\u0435\u043d\u044c \u043e\u0431\u0440\u0430\u0442\u043d\u043e\u0439 \u043a\u0440\u0438\u0432\u043e\u0439<br \/>\n- 50 \u043f\u0438\u043a\u0430\u043f\u043e\u0432: 8 \u00d7 FLA = 16 000A (\u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0439 40A)<br \/>\n- \u041d\u0430\u0432\u043e\u0434\u043a\u0430 51N: 0,5 \u0410 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0438 (200 \u0410 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u043e\u0439 \u043e\u0431\u043c\u043e\u0442\u043a\u0438, \u043d\u043e\u043c\u0438\u043d\u0430\u043b \u0422\u0422 10%)<br \/>\n- \u0426\u0438\u0444\u0435\u0440\u0431\u043b\u0430\u0442 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 51N: 0,3 \u043d\u0430 \u043e\u0447\u0435\u043d\u044c \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u043e\u0439 \u043a\u0440\u0438\u0432\u043e\u0439<br \/>\n- \u041d\u0430\u0432\u043e\u0434\u043a\u0430 50N: \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0430\u044f \u043e\u0431\u043c\u043e\u0442\u043a\u0430 2A (\u043f\u0435\u0440\u0432\u0438\u0447\u043d\u0430\u044f \u043e\u0431\u043c\u043e\u0442\u043a\u0430 800A)<\/p>\n<p>\u042d\u043b\u0435\u043c\u0435\u043d\u0442\u044b \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u044e\u0442\u0441\u044f \u0431\u043e\u043b\u0435\u0435 \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u043e\u0431\u044b\u0447\u043d\u043e \u0438\u043c\u0435\u044e\u0442 \u043c\u0435\u043d\u044c\u0448\u0443\u044e \u043c\u0430\u0433\u043d\u0438\u0442\u0443\u0434\u0443, \u0447\u0435\u043c \u0444\u0430\u0437\u043e\u0432\u044b\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043d\u043e \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u043e\u043d\u0438 \u043e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u043e \u043e\u043f\u0430\u0441\u043d\u044b.<\/p>\n<h3>\u041b\u043e\u0433\u0438\u043a\u0430 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043f\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e \u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0435 \u043f\u043e \u0442\u043e\u043a\u0443<\/h3>\n<p>\u0417\u0430\u0449\u0438\u0442\u0430 \u043e\u0442 \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (27) \u0438 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (59) \u0447\u0430\u0441\u0442\u043e \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442\u0441\u044f \u0441 \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u043f\u043e \u0442\u043e\u043a\u0443 \u0434\u043b\u044f \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0441\u0445\u0435\u043c\u044b:<\/p>\n<p><strong>\u041f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (51 \u0412)<\/strong> \u0443\u043c\u0435\u043d\u044c\u0448\u0430\u0435\u0442 \u043f\u043e\u0440\u043e\u0433 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u043f\u0440\u0438 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043f\u043e\u0432\u044b\u0448\u0430\u044f \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043a \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u044b\u043c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044f\u043c, \u043a\u043e\u0433\u0434\u0430 \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e, \u0430 \u0443\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0442\u043e\u043a\u0430 \u043d\u0435\u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e.<\/p>\n<p><strong>\u041f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443 \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/strong> \u0412\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u044d\u043b\u0435\u043c\u0435\u043d\u0442 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0441\u0432\u0435\u0440\u0445\u0442\u043e\u043a\u0430 \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u0440\u0438 \u043f\u0430\u0434\u0435\u043d\u0438\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043d\u0438\u0436\u0435 \u043f\u043e\u0440\u043e\u0433\u043e\u0432\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u0434\u043b\u044f \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u043e\u0432.<\/p>\n<h3>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/h3>\n<p>\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 86 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442 \u0432\u0445\u043e\u0434\u043d\u044b\u0435 \u0441\u0438\u0433\u043d\u0430\u043b\u044b \u043e\u0442 \u0432\u0441\u0435\u0445 \u0444\u0443\u043d\u043a\u0446\u0438\u0439 \u0437\u0430\u0449\u0438\u0442\u044b \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0435 \u0441\u0438\u0433\u043d\u0430\u043b\u044b:<br \/>\n- \u041f\u0435\u0440\u0432\u0438\u0447\u043d\u0430\u044f \u043a\u0430\u0442\u0443\u0448\u043a\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u043f\u0443\u0442\u044c 52a)<br \/>\n- \u0420\u0435\u0437\u0435\u0440\u0432\u043d\u0430\u044f \u043a\u0430\u0442\u0443\u0448\u043a\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u043f\u0440\u0438 \u043d\u0430\u043b\u0438\u0447\u0438\u0438)<br \/>\n- \u0411\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0449\u0438\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0446\u0435\u043f\u0438 (52Y)<br \/>\n- \u0421\u0438\u0433\u043d\u0430\u043b \u0442\u0440\u0435\u0432\u043e\u0433\u0438 SCADA\/DCS<br \/>\n- \u041c\u0435\u0441\u0442\u043d\u043e\u0435 \u043e\u043f\u043e\u0432\u0435\u0449\u0435\u043d\u0438\u0435<\/p>\n<hr \/>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 4: \u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0438 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u044b \u0438\u0437\u0431\u0438\u0440\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438<\/h2>\n<p>\u0414\u043b\u044f \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0439 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0430\u043d\u0430\u043b\u0438\u0437 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u0432\u0440\u0435\u043c\u044f-\u0442\u043e\u043a \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 \u0437\u0430\u0449\u0438\u0442\u044b.<\/p>\n<h3>\u0412\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438<\/h3>\n<p>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 (CTI) \u043c\u0435\u0436\u0434\u0443 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0432\u043e\u0441\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u0438 \u043d\u0438\u0441\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u043e\u0432 \u0434\u043e\u043b\u0436\u0435\u043d \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c:<br \/>\n- \u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f (\u043e\u0431\u044b\u0447\u043d\u043e 3-5 \u0446\u0438\u043a\u043b\u043e\u0432 \u0434\u043b\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 MV)<br \/>\n- \u041f\u0435\u0440\u0435\u0434\u0432\u0438\u0436\u0435\u043d\u0438\u0435 \u0440\u0435\u043b\u0435 (2-4 \u0446\u0438\u043a\u043b\u0430 \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445, \u043d\u0435\u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u0434\u043b\u044f \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445)<br \/>\n- \u0417\u0430\u043f\u0430\u0441 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 (5-10 \u0446\u0438\u043a\u043b\u043e\u0432)<\/p>\n<p>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0430 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 CTI \u0432 0,2-0,4 \u0441\u0435\u043a\u0443\u043d\u0434\u044b \u043c\u0435\u0436\u0434\u0443 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438. \u0424\u043e\u0440\u043c\u0443\u043b\u0430 \u0432\u044b\u0433\u043b\u044f\u0434\u0438\u0442 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u043c \u043e\u0431\u0440\u0430\u0437\u043e\u043c:<\/p>\n<p><strong>CTI = \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044f + \u043f\u0435\u0440\u0435\u0440\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043b\u0435 + \u0437\u0430\u043f\u0430\u0441 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438<\/strong><\/p>\n<p>\u0414\u043b\u044f \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445 \u0440\u0435\u043b\u0435 \u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439:<br \/>\nCTI = 0,08 \u0441 + 0,00 \u0441 + 0,12 \u0441 = 0,20 \u0441 \u043c\u0438\u043d\u0438\u043c\u0443\u043c<\/p>\n<h3>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u0441\u0432\u0435\u0440\u0445\u0442\u043e\u043a\u0430<\/h3>\n<p>\u0424\u0443\u043d\u043a\u0446\u0438\u044f 50 \u0441\u043e\u0437\u0434\u0430\u0435\u0442 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0441 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0435\u0439, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0430 \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0431\u0435\u0437 \u043f\u0440\u0435\u0434\u043d\u0430\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0439 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438. \u0418\u0437\u0431\u0438\u0440\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0434\u0432\u0443\u043c\u044f \u043f\u043e\u0434\u0445\u043e\u0434\u0430\u043c\u0438:<\/p>\n<p><strong>\u0421\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u0430\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0437\u043e\u043d (ZSI):<\/strong> \u0420\u0435\u043b\u0435 \u043d\u0438\u0441\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u043f\u043e\u0441\u044b\u043b\u0430\u044e\u0442 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u0441\u0438\u0433\u043d\u0430\u043b\u044b \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c \u0432\u043e\u0441\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u043f\u0440\u0438 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0432 \u0441\u0432\u043e\u0435\u0439 \u0437\u043e\u043d\u0435. \u0412\u043e\u0441\u0445\u043e\u0434\u044f\u0449\u0435\u0435 \u0440\u0435\u043b\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0440\u0430\u0431\u043e\u0442\u0443 \u043d\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u0438\u0439 \u043f\u0440\u043e\u043c\u0435\u0436\u0443\u0442\u043e\u043a \u0432\u0440\u0435\u043c\u0435\u043d\u0438 (\u043e\u0431\u044b\u0447\u043d\u043e 50-100 \u043c\u0441), \u0435\u0441\u043b\u0438 \u043e\u043d\u043e \u043d\u0435 \u043f\u043e\u043b\u0443\u0447\u0430\u0435\u0442 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0449\u0435\u0433\u043e \u0441\u0438\u0433\u043d\u0430\u043b\u0430, \u0447\u0442\u043e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0448\u0438\u043d\u044b.<\/p>\n<p><strong>\u041c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u0430\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043f\u0438\u043a\u0430\u043f\u0430:<\/strong> \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u044d\u043b\u0435\u043c\u0435\u043d\u0442 upstream 50 \u0432\u044b\u0448\u0435 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 downstream, \u0447\u0442\u043e\u0431\u044b \u0442\u043e\u043b\u044c\u043a\u043e \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 downstream \u0432\u044b\u0437\u044b\u0432\u0430\u043b\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435 upstream 50.<\/p>\n<hr \/>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 5: \u041f\u0440\u0438\u043c\u0435\u0440\u044b \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445<\/h2>\n<h3>\u041f\u0440\u0438\u043c\u0435\u0440 1: \u0424\u0438\u0434\u0435\u0440 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f 13,8 \u043a\u0412<\/h3>\n<p>\u0424\u0438\u0434\u0435\u0440 13,8 \u043a\u0412 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u044f \u043f\u0438\u0442\u0430\u0435\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c\u044e 3000 \u043a\u0412\u0410. \u0421\u0445\u0435\u043c\u0430 \u0437\u0430\u0449\u0438\u0442\u044b \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0432 \u0441\u0435\u0431\u044f:<\/p>\n<p><strong>\u041f\u0435\u0440\u0432\u0438\u0447\u043d\u0430\u044f \u0437\u0430\u0449\u0438\u0442\u0430:<\/strong><br \/>\n- 51: \u041f\u0438\u043a\u0430\u043f 125A, \u043e\u0447\u0435\u043d\u044c \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u044b\u0439, TD 3.0<br \/>\n- 50: \u041f\u0438\u043a\u0430\u043f 4000A (2\u00d7 \u043f\u0443\u0441\u043a\u043e\u0432\u043e\u0439 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440)<br \/>\n- 51N: \u041f\u0438\u043a\u0430\u043f 15A, \u043e\u0447\u0435\u043d\u044c \u0438\u043d\u0432\u0435\u0440\u0441\u043d\u044b\u0439, TD 2.0<br \/>\n- 50N: \u041f\u043e\u0434\u0431\u043e\u0440\u043a\u0430 200A<\/p>\n<p><strong>\u0412\u0437\u0430\u0438\u043c\u043e\u0441\u0432\u044f\u0437\u044c:<\/strong><br \/>\n\u0412\u0441\u0435 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u044b \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u044e\u0442 \u0447\u0435\u0440\u0435\u0437 86T (\u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430), \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0444\u0438\u0434\u0435\u0440\u043d\u044b\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c 13,8 \u043a\u0412 \u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0443\u044e \u0441\u0435\u0442\u044c 480 \u0412. \u042d\u043b\u0435\u043c\u0435\u043d\u0442 27 (\u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0439 \u043d\u0430 85%, \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 2,0 \u0441) \u0441\u0430\u043c\u043e\u0441\u0442\u043e\u044f\u0442\u0435\u043b\u044c\u043d\u043e \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0443\u044e \u0441\u0435\u0442\u044c 480 \u0412 \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u043f\u0440\u0438 \u043f\u0440\u043e\u0441\u0430\u0434\u043a\u0430\u0445 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n<h3>\u041f\u0440\u0438\u043c\u0435\u0440 2: \u041f\u0440\u0438\u0432\u044f\u0437\u043a\u0430 \u043a \u0448\u0438\u043d\u0435 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438 \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0445\u043e\u0437\u044f\u0439\u0441\u0442\u0432\u0430<\/h3>\n<p>\u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430 \u0448\u0438\u043d\u0430\u0445 34,5 \u043a\u0412 \u0437\u0430\u0449\u0438\u0449\u0430\u0435\u0442 \u043e\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0439 \u043d\u0430 \u0448\u0438\u043d\u0430\u0445 \u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443:<\/p>\n<p><strong>\u0412\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u0435 \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0439 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0437\u043e\u043d:<\/strong><br \/>\n- \u0420\u0435\u043b\u0435 \u0444\u0438\u0434\u0435\u0440\u0430 \u043f\u043e\u0441\u044b\u043b\u0430\u044e\u0442 \u0441\u0438\u0433\u043d\u0430\u043b\u044b \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 ZSI \u043d\u0430 \u0440\u0435\u043b\u0435 \u043e\u0431\u0432\u044f\u0437\u043a\u0438 \u0448\u0438\u043d\u044b<br \/>\n- \u0410\u0432\u0442\u043e\u0431\u0443\u0441\u043d\u044b\u0439 \u0433\u0430\u043b\u0441\u0442\u0443\u043a 51: \u041f\u0438\u043a\u0430\u043f 2000A, \u043e\u0447\u0435\u043d\u044c \u0438\u043d\u0432\u0435\u0440\u0441\u0438\u043e\u043d\u043d\u044b\u0439, TD 5.0<br \/>\n- \u041f\u0440\u0438\u0432\u044f\u0437\u043a\u0430 \u043a \u0448\u0438\u043d\u0435 50: \u041f\u043e\u0434\u0445\u0432\u0430\u0442 8000A, \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 100 \u043c\u0441 \u0431\u0435\u0437 \u0431\u043b\u043e\u043a\u0430 ZSI<br \/>\n- \u041f\u0440\u0438\u0432\u044f\u0437\u043a\u0430 \u043a \u0448\u0438\u043d\u0435 50N: \u041f\u043e\u0434\u0445\u0432\u0430\u0442 400A, \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430 100 \u043c\u0441 \u0431\u0435\u0437 \u0431\u043b\u043e\u043a\u0430 ZSI<\/p>\n<p>\u041f\u0440\u0438 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0444\u0438\u0434\u0435\u0440\u0430 \u0440\u0435\u043b\u0435 \u0444\u0438\u0434\u0435\u0440\u0430 \u043f\u043e\u0441\u044b\u043b\u0430\u0435\u0442 \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u044e\u0449\u0438\u0439 \u0441\u0438\u0433\u043d\u0430\u043b \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0440\u0430\u0431\u043e\u0442\u044b, \u0447\u0442\u043e\u0431\u044b \u0443\u0441\u0442\u0440\u0430\u043d\u0438\u0442\u044c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c. \u0415\u0441\u043b\u0438 \u0441\u0438\u0433\u043d\u0430\u043b \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442 (\u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u044c \u0448\u0438\u043d\u044b), \u0442\u043e \u0448\u0438\u043d\u043d\u0430\u044f \u043e\u0431\u0432\u044f\u0437\u043a\u0430 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u0435\u0442 \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e.<\/p>\n<hr \/>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 6: \u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/h2>\n<p>\u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u0432\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0435\u0442, \u0447\u0442\u043e \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043a\u0430\u0440\u0442\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u0442\u0430\u043a, \u043a\u0430\u043a \u0437\u0430\u0434\u0443\u043c\u0430\u043d\u043e.<\/p>\n<h3>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f<\/h3>\n<ol>\n<li><strong>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u043e\u0432:<\/strong> \u041f\u043e\u0434\u0430\u0439\u0442\u0435 \u0442\u0435\u0441\u0442\u043e\u0432\u044b\u0435 \u0442\u043e\u043a\u0438\/\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0447\u0442\u043e\u0431\u044b \u0443\u0431\u0435\u0434\u0438\u0442\u044c\u0441\u044f, \u0447\u0442\u043e \u043a\u0430\u0436\u0434\u044b\u0439 \u044d\u043b\u0435\u043c\u0435\u043d\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0435\u0442 \u043f\u0440\u0438 \u0437\u0430\u0434\u0430\u043d\u043d\u044b\u0445 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f\u0445 \u043d\u0430\u0432\u043e\u0434\u043a\u0438 \u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u0438.<\/li>\n<li><strong>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u043f\u0443\u0442\u0438 \u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f:<\/strong> \u041f\u0440\u043e\u0441\u043b\u0435\u0434\u0438\u0442\u0435 \u043a\u0430\u0436\u0434\u044b\u0439 \u0432\u044b\u0445\u043e\u0434 \u0440\u0435\u043b\u0435 \u0447\u0435\u0440\u0435\u0437 \u043b\u043e\u0433\u0438\u043a\u0443 \u0434\u043e \u043a\u0430\u0442\u0443\u0448\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f, \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u044f \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u043e\u0441\u0442\u044c \u0438 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0440\u0430\u0431\u043e\u0442\u044b.<\/li>\n<li><strong>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438:<\/strong> \u041c\u043e\u0434\u0435\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u0439 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0434\u043b\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 ZSI, \u0444\u0443\u043d\u043a\u0446\u0438\u0439 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0440\u0430\u0431\u043e\u0442\u044b \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438.<\/li>\n<li><strong>\u0412\u0435\u0440\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0441\u0431\u0440\u043e\u0441\u0430 \u0446\u0435\u043b\u0438:<\/strong> \u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e 86 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0440\u0443\u0447\u043d\u043e\u0433\u043e \u0441\u0431\u0440\u043e\u0441\u0430 \u0438 \u0434\u043e\u043b\u0436\u043d\u044b\u043c \u043e\u0431\u0440\u0430\u0437\u043e\u043c \u0431\u043b\u043e\u043a\u0438\u0440\u0443\u0435\u0442 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f.<\/li>\n<\/ol>\n<h3>\u041e\u0431\u0449\u0438\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e<\/h3>\n<p>\u041f\u043e \u043e\u043f\u044b\u0442\u0443 \u0440\u0430\u0431\u043e\u0442\u044b \u043d\u0430 \u043c\u0435\u0441\u0442\u0430\u0445, \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0447\u0430\u0441\u0442\u043e \u0432\u0441\u0442\u0440\u0435\u0447\u0430\u044e\u0449\u0438\u0435\u0441\u044f \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:<\/p>\n<ul>\n<li><strong>\u041e\u0448\u0438\u0431\u043a\u0438 \u043f\u043e\u043b\u044f\u0440\u043d\u043e\u0441\u0442\u0438 \u041a\u0422:<\/strong> \u042d\u043b\u0435\u043c\u0435\u043d\u0442\u044b \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u043c\u043e\u0433\u0443\u0442 \u0440\u0430\u0431\u043e\u0442\u0430\u0442\u044c \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e, \u0435\u0441\u043b\u0438 \u043f\u0440\u0438 \u0440\u0430\u0441\u0447\u0435\u0442\u0435 \u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u043b\u044f\u0440\u043d\u043e\u0441\u0442\u044c<\/li>\n<li><strong>\u041e\u0448\u0438\u0431\u043a\u0438 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438:<\/strong> \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u0446\u0435\u043f\u0435\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043c\u043e\u0436\u0435\u0442 \u043c\u0430\u0441\u043a\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043e\u0431\u0440\u044b\u0432\u044b \u0432 \u0446\u0435\u043f\u044f\u0445 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/li>\n<li><strong>\u041e\u0448\u0438\u0431\u043a\u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438:<\/strong> \u0417\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043f\u0438\u043a\u0430\u043f\u0430 \u0432\u0432\u0435\u0434\u0435\u043d\u044b \u0432 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0445 \u0435\u0434\u0438\u043d\u0438\u0446\u0430\u0445 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f (\u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u043e\u0442\u0438\u0432 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0445)<\/li>\n<li><strong>\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438:<\/strong> \u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u0435\u043d\u0442\u0438\u043b\u0435\u0439, \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u043b\u043e\u0436\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u043e\u0442\u043a\u0430\u0437 \u043e\u0442 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f<\/li>\n<\/ul>\n<hr \/>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 7: \u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0447\u0438\u0441\u043b\u0435\u043d\u043d\u0430\u044f \u0440\u0435\u043b\u0435\u0439\u043d\u0430\u044f \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f<\/h2>\n<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0441\u0445\u0435\u043c\u044b \u0437\u0430\u0449\u0438\u0442\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0447\u0438\u0441\u043b\u043e\u0432\u044b\u0445 \u0440\u0435\u043b\u0435 \u0434\u043b\u044f \u0440\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u0438\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0441\u0442\u0438.<\/p>\n<h3>\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u043b\u043e\u0433\u0438\u043a\u0438<\/h3>\n<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0440\u0435\u043b\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0442 \u0441\u043e\u0437\u0434\u0430\u0432\u0430\u0442\u044c \u0441\u043e\u0431\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0443\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044f:<\/p>\n<pre><code>TRIP = (50 \u0418\u041b\u0418 51 \u0418\u041b\u0418 50N \u0418\u041b\u0418 51N \u0418\u041b\u0418 27 \u0418\u041b\u0418 59) \u0418 \u041d\u0415 \u042f\u0412\u041b\u042f\u0415\u0422\u0421\u042f \u0411\u041b\u041e\u041a\u041e\u041c\n<\/code><\/pre>\n<p>\u0413\u0434\u0435 BLOCK \u043c\u043e\u0436\u0435\u0442 \u0431\u044b\u0442\u044c \u0432\u0445\u043e\u0434\u043e\u043c \u0440\u0435\u0436\u0438\u043c\u0430 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u0432\u043d\u0435\u0448\u043d\u0438\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435\u043c.<\/p>\n<h3>\u0421\u0445\u0435\u043c\u044b, \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u043a\u043e\u043c\u043c\u0443\u043d\u0438\u043a\u0430\u0446\u0438\u0438<\/h3>\n<p>\u041f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u0439 IEC 61850 GOOSE \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0441\u043a\u043e\u0440\u043e\u0441\u0442\u043d\u0443\u044e \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u0431\u0435\u0437 \u0436\u0435\u0441\u0442\u043a\u0438\u0445 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439. \u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:<\/p>\n<ul>\n<li>\u0414\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0441\u0445\u0435\u043c\u044b \u0448\u0438\u043d, \u0441\u043e\u043e\u0431\u0449\u0430\u044e\u0449\u0438\u0435\u0441\u044f \u043c\u0435\u0436\u0434\u0443 \u0444\u0438\u0434\u0435\u0440\u043d\u044b\u043c\u0438 \u0440\u0435\u043b\u0435<\/li>\n<li>\u041f\u0435\u0440\u0435\u0434\u0430\u0442\u043e\u0447\u043d\u043e\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u0440\u0435\u0437\u0435\u0440\u0432\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f<\/li>\n<li>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u0435\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u043b\u044f \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438<\/li>\n<\/ul>\n<h3>\u0417\u0430\u043f\u0438\u0441\u044c \u0438 \u0430\u043d\u0430\u043b\u0438\u0437 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/h3>\n<p>\u0427\u0438\u0441\u043b\u043e\u0432\u044b\u0435 \u0440\u0435\u043b\u0435 \u0444\u0438\u043a\u0441\u0438\u0440\u0443\u044e\u0442 \u043e\u0441\u0446\u0438\u043b\u043b\u043e\u0433\u0440\u0430\u043c\u043c\u044b \u0438 \u0437\u0430\u043f\u0438\u0441\u0438 \u0441\u043e\u0431\u044b\u0442\u0438\u0439, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u044b\u0435 \u0434\u043b\u044f \u0430\u043d\u0430\u043b\u0438\u0437\u0430 \u043f\u043e\u0441\u043b\u0435 \u0430\u0432\u0430\u0440\u0438\u0438. \u042d\u0442\u0438 \u0434\u0430\u043d\u043d\u044b\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0442 \u0440\u0430\u0431\u043e\u0442\u0443 \u043b\u043e\u0433\u0438\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u044f\u0432\u043b\u044f\u044e\u0442 \u043b\u044e\u0431\u044b\u0435 \u043d\u0430\u0440\u0443\u0448\u0435\u043d\u0438\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438.<\/p>\n<hr \/>\n<h2>\u0420\u0430\u0437\u0434\u0435\u043b 8: \u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e \u0438 \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c<\/h2>\n<p>\u0420\u0435\u043b\u0435\u0439\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0432\u0441\u0435\u0433\u043e \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b.<\/p>\n<h3>\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438<\/h3>\n<p>\u041e\u0441\u043d\u043e\u0432\u0430\u043d\u043e \u043d\u0430 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0435 NFPA 70B \u0438 \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0432\u043e\u0439 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435:<\/p>\n<ul>\n<li><strong>\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0435\u043b\u0435:<\/strong> \u0415\u0436\u0435\u0433\u043e\u0434\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435, \u043e\u0447\u0438\u0441\u0442\u043a\u0430 \u0438 \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u043a\u0430<\/li>\n<li><strong>\u0422\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0440\u0435\u043b\u0435:<\/strong> \u0414\u0432\u0443\u0445\u0433\u043e\u0434\u0438\u0447\u043d\u043e\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435<\/li>\n<li><strong>\u0427\u0438\u0441\u043b\u043e\u0432\u044b\u0435 \u0440\u0435\u043b\u0435:<\/strong> \u0421\u0430\u043c\u043e\u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u0442\u044c \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u0434\u043e 3-5-\u043b\u0435\u0442\u043d\u0438\u0445 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u043e\u0432.<\/li>\n<\/ul>\n<h3>\u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438<\/h3>\n<p>\u0412\u0435\u0434\u0438\u0442\u0435 \u0442\u043e\u0447\u043d\u044b\u0439 \u0443\u0447\u0435\u0442, \u0432\u043a\u043b\u044e\u0447\u0430\u044f:<br \/>\n- \u041e\u0440\u0438\u0433\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0440\u0435\u043b\u0435 \u0438 \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438<br \/>\n- \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0445\u0435\u043c\u044b \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u043c<br \/>\n- \u0420\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438 \u0434\u0430\u043d\u043d\u044b\u0435 \u043e \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u044f\u0445<br \/>\n- \u0418\u0441\u0442\u043e\u0440\u0438\u044f \u0440\u0435\u0432\u0438\u0437\u0438\u0439 \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0447\u0438\u0441\u043b\u043e\u0432\u044b\u0445 \u0440\u0435\u043b\u0435<br \/>\n- \u0410\u043d\u0430\u043b\u0438\u0437 \u0437\u0430\u043f\u0438\u0441\u0435\u0439 \u0441\u043e\u0431\u044b\u0442\u0438\u0439 \u0434\u043b\u044f \u043b\u044e\u0431\u044b\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/p>\n<hr \/>\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<h3>Q1: \u0417\u0430\u0447\u0435\u043c \u043d\u0430\u043c \u043d\u0443\u0436\u043d\u044b \u0444\u0443\u043d\u043a\u0446\u0438\u0438 50 \u0438 51, \u0435\u0441\u043b\u0438 \u043e\u043d\u0438 \u043e\u0431\u0435 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0443 \u043f\u043e \u0442\u043e\u043a\u0443?<\/h3>\n<p>\u0424\u0443\u043d\u043a\u0446\u0438\u0438 50 (\u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u0430\u044f) \u0438 51 (\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0430 \u043f\u043e \u0442\u043e\u043a\u0443) \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u044e\u0442 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u043e\u043f\u043e\u043b\u043d\u044f\u044e\u0449\u0438\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438. \u042d\u043b\u0435\u043c\u0435\u043d\u0442 51 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0441\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u0441 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u043a\u043e\u0442\u043e\u0440\u0430\u044f \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043d\u0438\u0436\u0435\u0441\u0442\u043e\u044f\u0449\u0438\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u0442\u044c \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0432\u044b\u043c\u0438, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044f \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c. \u042d\u043b\u0435\u043c\u0435\u043d\u0442 50 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0432\u044b\u0441\u043e\u043a\u043e\u0441\u043a\u043e\u0440\u043e\u0441\u0442\u043d\u0443\u044e \u0437\u0430\u0449\u0438\u0442\u0443 \u043f\u0440\u0438 \u0441\u0435\u0440\u044c\u0435\u0437\u043d\u044b\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f\u0445 \u0432\u0431\u043b\u0438\u0437\u0438 \u043c\u0435\u0441\u0442\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0440\u0435\u043b\u0435, \u0433\u0434\u0435 \u0432\u0435\u0440\u043e\u044f\u0442\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0430, \u0430 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u0441 \u043d\u0438\u0436\u0435\u0441\u0442\u043e\u044f\u0449\u0438\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u043d\u0435\u0432\u043e\u0437\u043c\u043e\u0436\u043d\u0430 \u0438\u043b\u0438 \u043d\u0435 \u043d\u0443\u0436\u043d\u0430. \u0412\u043c\u0435\u0441\u0442\u0435 \u043e\u043d\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043f\u043e\u043b\u043d\u043e\u0435 \u043f\u043e\u043a\u0440\u044b\u0442\u0438\u0435: \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u043f\u0440\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f\u0445 \u0438 \u0431\u044b\u0441\u0442\u0440\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u043f\u0440\u0438 \u0431\u043b\u0438\u0437\u043a\u0438\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f\u0445.<\/p>\n<h3>\u0412\u043e\u043f\u0440\u043e\u0441 2: \u041a\u0430\u043a \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c, \u043d\u0443\u0436\u043d\u043e \u043b\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c 86 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0438\u043b\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u0442\u044c \u043d\u0435\u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b?<\/h3>\n<p>\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 86 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438, \u0435\u0441\u043b\u0438 \u0438\u043c\u0435\u0435\u0442 \u043c\u0435\u0441\u0442\u043e \u043b\u044e\u0431\u043e\u0435 \u0438\u0437 \u044d\u0442\u0438\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439: (1) \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0437\u0430\u0449\u0438\u0442\u044b \u0437\u0430\u0449\u0438\u0449\u0430\u044e\u0442 \u043e\u0434\u043d\u043e \u0438 \u0442\u043e \u0436\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0438 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u0438\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438; (2) \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u043b\u0436\u043d\u043e \u0431\u044b\u0442\u044c \u0437\u0430\u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u0430\u043d\u043e \u0434\u043e \u0437\u0430\u0432\u0435\u0440\u0448\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438; (3) \u0441\u0445\u0435\u043c\u0430 \u0437\u0430\u0449\u0438\u0442\u044b \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0447\u0435\u0442\u043a\u043e\u0433\u043e \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430 \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u0430 \u0434\u043b\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438; \u0438\u043b\u0438 (4) \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043d\u0430\u043b\u0438\u0447\u0438\u044f \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u0440\u0443\u0447\u043d\u043e\u0433\u043e \u0441\u0431\u0440\u043e\u0441\u0430. \u041f\u0440\u044f\u043c\u043e\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u043e\u0434\u0445\u043e\u0434\u0438\u0442 \u0434\u043b\u044f \u043f\u0440\u043e\u0441\u0442\u044b\u0445, \u043d\u0435\u043a\u0440\u0438\u0442\u0438\u0447\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439, \u0433\u0434\u0435 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0438\u0435\u043c\u043b\u0435\u043c\u043e, \u0430 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043f\u0435\u0440\u0432\u043e\u043e\u0447\u0435\u0440\u0435\u0434\u043d\u043e\u0439 \u0437\u0430\u0434\u0430\u0447\u0435\u0439.<\/p>\n<h3>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041a\u0430\u043a\u043e\u0439 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 (CTI) \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043c\u0435\u0436\u0434\u0443 \u043a\u0440\u0438\u0432\u044b\u043c\u0438 \u0440\u0435\u043b\u0435?<\/h3>\n<p>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0439 CTI \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0445 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0439 \u0440\u0435\u043b\u0435 \u0438 \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u0435\u0439. \u0414\u043b\u044f \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445 \u0440\u0435\u043b\u0435 \u0441 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u043c\u0438 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f\u043c\u0438 \u043e\u0431\u044b\u0447\u043d\u043e \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e 0,20-0,25 \u0441\u0435\u043a\u0443\u043d\u0434\u044b. \u041f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0440\u0435\u043b\u0435 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c 0,30-0,40 \u0441\u0435\u043a\u0443\u043d\u0434\u044b \u0434\u043b\u044f \u0443\u0447\u0435\u0442\u0430 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 \u0440\u0435\u043b\u0435. \u0414\u043b\u044f \u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0439 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0441\u0435\u0440\u0438\u0438, \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0435\u0439 \u043e\u0431\u0435 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0431\u043e\u043b\u044c\u0448\u0435\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435. \u0412\u0441\u0435\u0433\u0434\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0439\u0442\u0435 \u0430\u0434\u0435\u043a\u0432\u0430\u0442\u043d\u043e\u0441\u0442\u044c CTI \u043f\u0440\u0438 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u0443\u0440\u043e\u0432\u043d\u044f\u0445 \u0442\u043e\u043a\u0430, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u043f\u0440\u0438 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f, \u0433\u0434\u0435 \u043a\u0440\u0438\u0432\u044b\u0435 \u043c\u043e\u0433\u0443\u0442 \u0441\u0445\u043e\u0434\u0438\u0442\u044c\u0441\u044f.<\/p>\n<h3>\u0412\u043e\u043f\u0440\u043e\u0441 4: \u041c\u043e\u0436\u0435\u0442 \u043b\u0438 \u0437\u043e\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u0430\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 (ZSI) \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0443\u044e \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044e \u0432\u0440\u0435\u043c\u0435\u043d\u0438?<\/h3>\n<p>\u041d\u0435\u0442. ZSI \u0443\u043b\u0443\u0447\u0448\u0430\u0435\u0442 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044e \u0432\u0440\u0435\u043c\u0435\u043d\u0438, \u043d\u043e \u043d\u0435 \u0437\u0430\u043c\u0435\u043d\u044f\u0435\u0442 \u0435\u0435. \u0421\u0445\u0435\u043c\u0430 \u0434\u043e\u043b\u0436\u043d\u0430 \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u0442\u044c \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u0434\u0430\u0436\u0435 \u043f\u0440\u0438 \u0441\u0431\u043e\u0435 \u0441\u0432\u044f\u0437\u0438 ZSI. \u0420\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u0439\u0442\u0435 ZSI \u043a\u0430\u043a \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0435\u0435 \u0443\u0441\u043a\u043e\u0440\u0438\u0442\u044c \u0440\u0430\u0431\u043e\u0442\u0443 \u0440\u0435\u043b\u0435 \u043f\u0440\u0438 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f\u0445 \u043d\u0430 \u0448\u0438\u043d\u0430\u0445, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044f \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b. \u0412\u0441\u0435\u0433\u0434\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u0443\u0439\u0442\u0435 \u0431\u0430\u0437\u043e\u0432\u0443\u044e \u0441\u0445\u0435\u043c\u0443 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0442\u0430\u043a, \u0447\u0442\u043e\u0431\u044b \u043e\u043d\u0430 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043b\u0430 \u0431\u0435\u0437 ZSI, \u0430 \u0437\u0430\u0442\u0435\u043c \u0434\u043e\u0431\u0430\u0432\u043b\u044f\u0439\u0442\u0435 ZSI \u0434\u043b\u044f \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0432 \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0445 \u043c\u0435\u0441\u0442\u0430\u0445 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f.<\/p>\n<h3>Q5: \u041a\u0430\u043a \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u044c \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u044b 50N\/51N \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0435 \u0441 \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u043d\u044b\u043c \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435\u043c?<\/h3>\n<p>\u0412 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441 \u0440\u0435\u0437\u0438\u0441\u0442\u0438\u0432\u043d\u044b\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435\u043c \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u0440\u0435\u0437\u0438\u0441\u0442\u043e\u0440\u043e\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f \u043d\u0435\u0439\u0442\u0440\u0430\u043b\u0438 (NGR). \u0427\u0442\u043e\u0431\u044b \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0442\u044c \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043a \u0432\u044b\u0441\u043e\u043a\u043e\u043e\u043c\u043d\u044b\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f\u043c, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044f \u043f\u0440\u0438 \u044d\u0442\u043e\u043c \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u043d\u0435\u0441\u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435, \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435 \u043d\u0430\u0432\u043e\u0434\u043a\u0443 51N \u043d\u0430 10-25% \u043e\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 NGR. \u041d\u0430\u0432\u043e\u0434\u043a\u0430 50N \u0434\u043e\u043b\u0436\u043d\u0430 \u0431\u044b\u0442\u044c \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0430 \u043d\u0430 50-80% \u043e\u0442 \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e. \u0412\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f \u043c\u0435\u043d\u0435\u0435 \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u0430, \u0447\u0435\u043c \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u0441 \u0442\u0432\u0435\u0440\u0434\u044b\u043c \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435\u043c, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432\u0441\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u043d\u0430 \u0437\u0435\u043c\u043b\u044e \u0432\u044b\u0437\u044b\u0432\u0430\u044e\u0442 \u043e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043a\u0430 \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e \u043e\u0442 \u043c\u0435\u0441\u0442\u0430, \u043d\u043e \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u0430\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u044f 51N \u0432\u0441\u0435 \u0440\u0430\u0432\u043d\u043e \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u0430, \u0435\u0441\u043b\u0438 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u044b \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e.<\/p>\n<h3>Q6: \u0427\u0442\u043e \u0432\u044b\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0435\u043f\u0440\u0438\u044f\u0442\u043d\u044b\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0432 \u0441\u0445\u0435\u043c\u0430\u0445 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f (27)?<\/h3>\n<p>\u041a \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u043d\u044b\u043c \u043f\u0440\u0438\u0447\u0438\u043d\u0430\u043c \u043e\u0442\u043d\u043e\u0441\u044f\u0442\u0441\u044f: (1) \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u043a\u043e\u0440\u043e\u0442\u043a\u0430\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430, \u043d\u0435 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u0442\u044c \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u044b\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u044b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0437\u0430\u043f\u0443\u0441\u043a\u0435 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438; (2) \u0441\u043b\u0438\u0448\u043a\u043e\u043c \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043d\u0430\u0432\u043e\u0434\u043a\u0438 \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u043d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043b\u0435\u0431\u0430\u043d\u0438\u0439 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f; (3) \u043d\u0435\u0430\u0434\u0435\u043a\u0432\u0430\u0442\u043d\u044b\u0435 \u0440\u0430\u0441\u0447\u0435\u0442\u044b \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0422\u041d, \u043f\u0440\u0438\u0432\u043e\u0434\u044f\u0449\u0438\u0435 \u043a \u043e\u0448\u0438\u0431\u043a\u0430\u043c \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f; (4) \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0441 \u0432\u044b\u0448\u0435\u0441\u0442\u043e\u044f\u0449\u0438\u043c\u0438 \u0440\u0435\u0433\u0443\u043b\u044f\u0442\u043e\u0440\u0430\u043c\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0420\u041f\u041d; (5) \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0430 \u0422\u041d, \u043f\u0440\u0438\u0432\u043e\u0434\u044f\u0449\u0430\u044f \u043a \u043f\u0430\u0434\u0435\u043d\u0438\u044e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f. \u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432 \u0441\u0435\u0431\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0438 2-5 \u0441\u0435\u043a\u0443\u043d\u0434 \u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u043f\u043e\u0434\u0445\u0432\u0430\u0442\u0430 \u043d\u0430 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 80-85%, \u0445\u043e\u0442\u044f \u0434\u043b\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0434\u0440\u0443\u0433\u0438\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f.<\/p>\n<h3>Q7: \u041a\u0430\u043a \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0435 \u0440\u0435\u043b\u0435 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u044e\u0442 \u0444\u0443\u043d\u043a\u0446\u0438\u044e \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0432\u043d\u0443\u0442\u0440\u0438 \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0432\u043d\u0435\u0448\u043d\u0438\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 86?<\/h3>\n<p>\u0427\u0438\u0441\u043b\u043e\u0432\u044b\u0435 \u0440\u0435\u043b\u0435 \u043c\u043e\u0433\u0443\u0442 \u0440\u0435\u0430\u043b\u0438\u0437\u043e\u0432\u044b\u0432\u0430\u0442\u044c \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0432\u043d\u0443\u0442\u0440\u0438, \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044f \u0437\u0430\u043f\u0435\u0440\u0442\u043e\u0435 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0440\u0443\u0447\u043d\u043e\u0433\u043e \u0441\u0431\u0440\u043e\u0441\u0430 \u0447\u0435\u0440\u0435\u0437 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0435\u043b\u0435 \u0438\u043b\u0438 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441 \u0441\u0432\u044f\u0437\u0438. \u041e\u0434\u043d\u0430\u043a\u043e \u0432\u043d\u0435\u0448\u043d\u0438\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 86 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043e\u043d\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442: (1) \u0436\u0435\u0441\u0442\u043a\u0443\u044e, \u043e\u0442\u043a\u0430\u0437\u043e\u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u0443\u044e \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u0446\u0435\u043f\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f, (2) \u0432\u0438\u0434\u0438\u043c\u044b\u0435 \u0446\u0435\u043b\u0435\u0432\u044b\u0435 \u0444\u043b\u0430\u0433\u0438, \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0435 \u043e\u043f\u0440\u043e\u0441\u0430 \u0440\u0435\u043b\u0435, (3) \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0440\u0443\u0447\u043d\u043e\u0439 \u0441\u0431\u0440\u043e\u0441, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0439 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u0430, \u0438 (4) \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u044c \u043e\u0442 \u043d\u0430\u043b\u0438\u0447\u0438\u044f \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0440\u0435\u043b\u0435. \u041d\u0430 \u043c\u043d\u043e\u0433\u0438\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u0430\u0445 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u044e\u0442\u0441\u044f \u043e\u0431\u0430 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u0430: \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u044f\u044f \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0435\u0440\u0432\u043e\u0439 \u043b\u0438\u043d\u0438\u0438 \u0438 \u0432\u043d\u0435\u0448\u043d\u0438\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 86 \u0434\u043b\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u044f \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u044b\u0445 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439.<\/p>\n<hr \/>\n<h2>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435: \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0432\u044b\u0432\u043e\u0434\u044b<\/h2>\n<p>\u042d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043b\u043e\u0433\u0438\u043a\u0438 \u0440\u0435\u043b\u0435\u0439\u043d\u043e\u0433\u043e \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0432 \u043f\u0430\u043d\u0435\u043b\u044f\u0445 MV \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u0438\u0445 \u0444\u0443\u043d\u043a\u0446\u0438\u0439 \u0437\u0430\u0449\u0438\u0442\u044b \u0432 \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u0441\u0445\u0435\u043c\u0443. \u041e\u0441\u043d\u043e\u0432\u043e\u043f\u043e\u043b\u0430\u0433\u0430\u044e\u0449\u0438\u0435 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u044b \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442 \u0432 \u0441\u0435\u0431\u044f:<\/p>\n<ol>\n<li><strong>\u041c\u043d\u043e\u0433\u043e\u0441\u043b\u043e\u0439\u043d\u0430\u044f \u0437\u0430\u0449\u0438\u0442\u0430:<\/strong> \u041a\u043e\u043c\u0431\u0438\u043d\u0438\u0440\u0443\u0439\u0442\u0435 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u044b \u0441 \u043c\u0433\u043d\u043e\u0432\u0435\u043d\u043d\u043e\u0439 (50\/50N) \u0438 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u043e\u0439 (51\/51N) \u0434\u043b\u044f \u0434\u043e\u0441\u0442\u0438\u0436\u0435\u043d\u0438\u044f \u0441\u043a\u043e\u0440\u043e\u0441\u0442\u0438 \u0438 \u0441\u0435\u043b\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u0438.<\/li>\n<li><strong>\u0421\u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f:<\/strong> \u0421\u043e\u0431\u043b\u044e\u0434\u0430\u0439\u0442\u0435 \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u044b \u043c\u0435\u0436\u0434\u0443 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438, \u0447\u0442\u043e\u0431\u044b \u0440\u0435\u043b\u0435 \u043d\u0438\u0436\u0435\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0443\u0441\u0442\u0440\u0430\u043d\u044f\u043b\u0438 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0434\u043e \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0432\u044b\u0448\u0435\u0441\u0442\u043e\u044f\u0449\u0435\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f.<\/li>\n<li><strong>\u0426\u0435\u043d\u0442\u0440\u0430\u043b\u0438\u0437\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043b\u043e\u0433\u0438\u043a\u0430 \u043f\u043e\u0435\u0437\u0434\u043e\u043a:<\/strong> \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0440\u0435\u043b\u0435 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 (86) \u0434\u043b\u044f \u043e\u0431\u044a\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0432\u044b\u0445\u043e\u0434\u043e\u0432 \u0437\u0430\u0449\u0438\u0442\u044b, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439.<\/li>\n<li><strong>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e:<\/strong> \u0412\u043a\u043b\u044e\u0447\u0438\u0442\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u0433\u043e (27) \u0438 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0433\u043e (59) \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0443\u0441\u043b\u043e\u0432\u0438\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0435 \u043c\u043e\u0433\u0443\u0442 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u044b, \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u0442\u043e\u043a\u0435.<\/li>\n<li><strong>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0438 \u0432\u0430\u043b\u0438\u0434\u0430\u0446\u0438\u044f:<\/strong> \u0421\u0442\u0440\u043e\u0433\u0438\u0439 \u0432\u0432\u043e\u0434 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0438 \u043f\u0435\u0440\u0438\u043e\u0434\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043a\u0430\u0440\u0442\u044b \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043d\u0430 \u043f\u0440\u043e\u0442\u044f\u0436\u0435\u043d\u0438\u0438 \u0432\u0441\u0435\u0433\u043e \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/li>\n<li><strong>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044f:<\/strong> \u0412\u0435\u0434\u0438\u0442\u0435 \u0442\u043e\u0447\u043d\u044b\u0435 \u0437\u0430\u043f\u0438\u0441\u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0435\u043a, \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 \u0438 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u043e\u0432 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0434\u043b\u044f \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0438 \u043f\u043e\u0438\u0441\u043a\u0430 \u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439 \u0438 \u0431\u0443\u0434\u0443\u0449\u0438\u0445 \u043c\u043e\u0434\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0439.<\/li>\n<\/ol>\n<p>\u0418\u043d\u0432\u0435\u0441\u0442\u0438\u0446\u0438\u0438 \u0432 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e \u0441\u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u0438 \u0432\u0432\u0435\u0434\u0435\u043d\u043d\u0443\u044e \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043b\u043e\u0433\u0438\u043a\u0443 \u0440\u0435\u043b\u0435\u0439\u043d\u043e\u0433\u043e \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438\u043d\u043e\u0441\u044f\u0442 \u0434\u0438\u0432\u0438\u0434\u0435\u043d\u0434\u044b \u0432 \u0432\u0438\u0434\u0435 \u0443\u043b\u0443\u0447\u0448\u0435\u043d\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043f\u0440\u043e\u0441\u0442\u043e\u044f \u0438 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b\u0430. \u041f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0430\u0435\u0442 \u0440\u0430\u0437\u0432\u0438\u0432\u0430\u0442\u044c\u0441\u044f \u0437\u0430 \u0441\u0447\u0435\u0442 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445 \u043a\u043e\u043c\u043c\u0443\u043d\u0438\u043a\u0430\u0446\u0438\u0439 \u0438 \u043f\u0435\u0440\u0435\u0434\u043e\u0432\u043e\u0439 \u0430\u043d\u0430\u043b\u0438\u0442\u0438\u043a\u0438, \u044d\u0442\u0438 \u0444\u0443\u043d\u0434\u0430\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0440\u0438\u043d\u0446\u0438\u043f\u044b \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0438 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043e\u0441\u0442\u0430\u044e\u0442\u0441\u044f \u0432\u0430\u0436\u043d\u044b\u043c\u0438 \u0434\u043b\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u044b.<\/p>\n<hr \/>\n<p><em>\u0414\u043b\u044f \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432 \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u043d\u043e\u043c\u0443 \u0440\u0435\u043b\u0435 \u041a\u043e\u043c\u0438\u0442\u0435\u0442 \u043f\u043e \u0440\u0435\u043b\u0435 \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044e \u044d\u043d\u0435\u0440\u0433\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u0430\u043c\u0438 IEEE (PSRCC) \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442 \u0432\u0441\u0435\u0441\u0442\u043e\u0440\u043e\u043d\u043d\u0438\u0435 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0438 \u0443\u0447\u0435\u0431\u043d\u044b\u0435 \u043f\u043e\u0441\u043e\u0431\u0438\u044f \u043d\u0430 \u0441\u0430\u0439\u0442\u0435 <a href=\"https:\/\/www.pes-psrc.org\/\" target=\"_blank\" rel=\"noopener\">IEEE PES PSRCC<\/a>.<\/em><\/p>\n<hr \/>\n<h2>\u0421\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u044b<\/h2>\n<ul>\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-contactor\/\">\u043e\u0431\u0437\u043e\u0440 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440\u0430<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/\">\u0430\u0441\u0441\u043e\u0440\u0442\u0438\u043c\u0435\u043d\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/power-distribution-transformers\/\">\u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0441\u0438\u043b\u043e\u0432\u044b\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043e\u0432<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/\">\u0434\u0435\u0442\u0430\u043b\u0438 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u044b \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/contact-box\/\">\u0434\u0435\u0442\u0430\u043b\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u043a\u043e\u0440\u043e\u0431\u043a\u0438 \u0438\u0437 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u043e\u0439 \u0441\u043c\u043e\u043b\u044b<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/99635\" target=\"_blank\" rel=\"noopener\">\u0421\u0442\u0440\u0430\u043d\u0438\u0446\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438 IEC 62271-100<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A Comprehensive Technical Guide to Protective Relay Coordination and Interlocking Schemes Introduction In medium voltage (MV) electrical distribution systems, protective relays serve as the critical first line of defense against electrical faults, equipment damage, and personnel hazards. Understanding how these relays interlock and communicate through trip logic maps is fundamental to designing, commissioning, and maintaining [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3680,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3685","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/3685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=3685"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/3685\/revisions"}],"predecessor-version":[{"id":3818,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/3685\/revisions\/3818"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/3680"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=3685"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=3685"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=3685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}