{"id":3691,"date":"2026-05-10T09:00:00","date_gmt":"2026-05-10T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3691"},"modified":"2026-06-18T08:23:55","modified_gmt":"2026-06-18T08:23:55","slug":"terminal-blocks-control-wiring-switchgear-manufacturers","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/terminal-blocks-control-wiring-switchgear-manufacturers\/","title":{"rendered":"\u041a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432: \u041c\u0430\u0440\u043a\u0438, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044b \u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a \u0434\u043b\u044f \u0432\u044b\u0431\u043e\u0440\u0430"},"content":{"rendered":"<h2>\u0412\u0432\u0435\u0434\u0435\u043d\u0438\u0435: \u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0440\u043e\u043b\u044c \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/h2>\n<p>\u0417\u0430 \u0434\u0432\u0430\u0434\u0446\u0430\u0442\u044c \u0442\u0440\u0438 \u0433\u043e\u0434\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u044f \u0441\u0442\u0430\u043b \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u0435\u043c \u0431\u0435\u0441\u0447\u0438\u0441\u043b\u0435\u043d\u043d\u044b\u0445 \u043e\u0442\u043a\u0430\u0437\u043e\u0432 \u043f\u0430\u043d\u0435\u043b\u0435\u0439, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0431\u044b\u043b\u0438 \u0441\u0432\u044f\u0437\u0430\u043d\u044b \u043d\u0435 \u0441 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u043c\u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u043c\u0438 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u0430\u043c\u0438, \u0430 \u0441, \u043a\u0430\u0437\u0430\u043b\u043e\u0441\u044c \u0431\u044b, \u043d\u0435\u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u0430\u043c\u0438: \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u043c\u0438 \u043a\u043e\u043b\u043e\u0434\u043a\u0430\u043c\u0438, \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u044b\u043c\u0438 \u043a\u0430\u043d\u0430\u043b\u0430\u043c\u0438, \u043d\u0430\u043a\u043e\u043d\u0435\u0447\u043d\u0438\u043a\u0430\u043c\u0438 \u0438 \u0430\u043a\u0441\u0435\u0441\u0441\u0443\u0430\u0440\u0430\u043c\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438. \u042d\u0442\u0438 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b, \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u0435, \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e, 2-5% \u043e\u0442 \u043e\u0431\u0449\u0435\u0439 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u0432\u043b\u0438\u044f\u044e\u0442 \u043d\u0430 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b, \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u0434\u043e\u043b\u0433\u043e\u0441\u0440\u043e\u0447\u043d\u0443\u044e \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438.<\/p>\n<p>\u041a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0441\u043b\u0443\u0436\u0430\u0442 \u0442\u043e\u0447\u043a\u0430\u043c\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445, \u0441\u043e\u0435\u0434\u0438\u043d\u044f\u044f \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b, \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u0447\u0435\u0442\u0430, \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u0438 \u0438 \u043a\u043e\u043c\u043c\u0443\u043d\u0438\u043a\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u0441\u0435\u0442\u0438. \u041e\u0434\u0438\u043d \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0439 \u0431\u043b\u043e\u043a \u0441 \u043f\u043b\u043e\u0445\u0438\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043a\u0430\u0441\u043a\u0430\u0434\u043d\u044b\u0439 \u043e\u0442\u043a\u0430\u0437 \u043d\u0430 \u0432\u0441\u0435\u0439 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438. \u042f \u0443\u0441\u0432\u043e\u0438\u043b \u044d\u0442\u043e\u0442 \u0443\u0440\u043e\u043a \u0432 \u0441\u0430\u043c\u043e\u043c \u043d\u0430\u0447\u0430\u043b\u0435 \u0441\u0432\u043e\u0435\u0439 \u043a\u0430\u0440\u044c\u0435\u0440\u044b, \u043a\u043e\u0433\u0434\u0430 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043b\u0435\u0442\u043d\u0435\u0439 \u0436\u0430\u0440\u044b \u043d\u0430 \u043d\u0435\u0444\u0442\u0435\u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043f\u0440\u0435\u0434\u043f\u0440\u0438\u044f\u0442\u0438\u0438 \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0435 15 \u043a\u0412 \u043f\u0440\u043e\u0438\u0437\u043e\u0448\u0435\u043b \u043e\u0442\u043a\u0430\u0437 \u0446\u0435\u043f\u0435\u0439 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f - \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043c\u044b \u043f\u043e\u0441\u0442\u0430\u0432\u0438\u043b\u0438, \u043d\u0435 \u0432\u044b\u0434\u0435\u0440\u0436\u0430\u043b\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b 65 \u00b0C \u0432\u043d\u0443\u0442\u0440\u0438 \u0448\u043a\u0430\u0444\u0430.<\/p>\n<p>\u042d\u0442\u043e \u0432\u0441\u0435\u043e\u0431\u044a\u0435\u043c\u043b\u044e\u0449\u0435\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e, \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u043d\u0430 \u0440\u0435\u0430\u043b\u044c\u043d\u043e\u043c \u043e\u043f\u044b\u0442\u0435 \u043c\u043e\u043d\u0442\u0430\u0436\u0430, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0438 \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0432\u044b\u0445 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u0445, \u043f\u043e\u043c\u043e\u0436\u0435\u0442 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u0430\u043c, \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u0430\u043c \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u0430\u043c \u043f\u043e \u0437\u0430\u043a\u0443\u043f\u043a\u0430\u043c \u0432\u044b\u0431\u0440\u0430\u0442\u044c \u043e\u043f\u0442\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u041c\u044b \u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u043c \u0432\u0435\u0434\u0443\u0449\u0438\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439, \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u043c \u0447\u0435\u0442\u043a\u0438\u0435 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u0432\u044b\u0431\u043e\u0440\u0430 \u0438 \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u0438\u043c \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0435 \u0441\u043f\u0438\u0441\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u044b \u0441\u043c\u043e\u0436\u0435\u0442\u0435 \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u0442\u044c \u0432 \u0441\u0432\u043e\u0435\u043c \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear.webp\" alt=\"\u041f\u043e\u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043d\u0430\u044f \u0434\u0438\u0430\u0433\u0440\u0430\u043c\u043c\u0430, \u0441\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u044e\u0449\u0430\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u044e\u044e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044e \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0445 \u0438 \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u0445 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\" class=\"wp-image-3687\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-01-spring-clamp-vs-screw-terminal-block-switchgear-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0445 \u0438 \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u0445 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 \u0437\u0430\u0436\u0438\u043c\u0430 \u0438 \u0437\u043e\u043d\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430 \u0441 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u043c.<\/figcaption><\/figure>\n<h2>\u041f\u043e\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0439 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445<\/h2>\n<p>\u0426\u0435\u043f\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043e\u0431\u044b\u0447\u043d\u043e \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0442 \u043f\u0440\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 24-250 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438\u043b\u0438 120-240 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, \u043f\u043e\u044d\u0442\u043e\u043c\u0443 \u0442\u0440\u0435\u0431\u0443\u044e\u0442\u0441\u044f \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u044d\u0442\u0438 \u0443\u0440\u043e\u0432\u043d\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0449\u0438\u0435 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0435 \u043f\u043e\u043c\u0435\u0445\u0438 \u0438 \u0442\u0435\u043f\u043b\u043e\u0432\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f, \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0432 \u0441\u0440\u0435\u0434\u0430\u0445 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n<h3>\u041a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u043f\u0435\u0440\u0432\u0438\u0447\u043d\u044b\u0445 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432<\/h3>\n<p><strong>\u041a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438<\/strong> \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u044e\u0442 \u043e\u0441\u043d\u043e\u0432\u0443 \u0441\u0438\u0441\u0442\u0435\u043c \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f. \u0414\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u043c\u044b \u043e\u0431\u044b\u0447\u043d\u043e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u043c:<br \/>\n\u2013 <strong>\u041f\u0440\u043e\u0445\u043e\u0434\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b<\/strong> \u0434\u043b\u044f \u043e\u0431\u0449\u0435\u0433\u043e \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0441\u0438\u0433\u043d\u0430\u043b\u043e\u0432 \u0438 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438<br \/>\n\u2013 <strong>\u041a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0441 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f\u043c\u0438<\/strong> \u0437\u0430\u0449\u0438\u0442\u0430 \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439 \u0422\u0422 \u0438 \u041f\u0422<br \/>\n\u2013 <strong>\u0420\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b<\/strong> \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u0446\u0435\u043f\u0438 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<br \/>\n\u2013 <strong>\u041a\u043b\u0435\u043c\u043c\u044b \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f<\/strong> \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u0435 \u043d\u0430\u0434\u043b\u0435\u0436\u0430\u0449\u0435\u0433\u043e \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0433\u043e \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u044f<br \/>\n\u2013 <strong>\u041a\u043b\u0435\u043c\u043c\u044b \u0434\u0430\u0442\u0447\u0438\u043a\u043e\u0432\/\u0438\u0441\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u0432<\/strong> \u0441\u043e \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u043c\u0438 \u0438\u043d\u0434\u0438\u043a\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0434\u043b\u044f \u043f\u043e\u0438\u0441\u043a\u0430 \u0438 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u043d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0435\u0439<\/p>\n<p><strong>\u041a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0434\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u0430\u043c\u0438<\/strong> \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:<br \/>\n- \u0429\u0435\u043b\u0435\u0432\u043e\u0439 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0439 \u043a\u0430\u043d\u0430\u043b (\u043f\u043e \u0442\u0438\u043f\u0443 Panduit \u0438\u043b\u0438 \u044d\u043a\u0432\u0438\u0432\u0430\u043b\u0435\u043d\u0442\u043d\u044b\u0439)<br \/>\n- \u0421\u043f\u0438\u0440\u0430\u043b\u044c\u043d\u0430\u044f \u043e\u0431\u043c\u043e\u0442\u043a\u0430 \u0438 \u043f\u043b\u0435\u0442\u0435\u043d\u044b\u0435 \u0440\u0443\u043a\u0430\u0432\u0430<br \/>\n- \u041a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u044f\u0436\u043a\u0438 \u0438 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u044b\u0435 \u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u044f<br \/>\n- \u0424\u0438\u0442\u0438\u043d\u0433\u0438 \u0434\u043b\u044f \u043a\u0430\u0431\u0435\u043b\u0435\u0439 \u0438 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u044b\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u0438<\/p>\n<p>\u0412 \u0440\u0430\u043c\u043a\u0430\u0445 \u0442\u043e\u0433\u043e \u0436\u0435 \u0441\u0430\u043c\u043e\u0433\u043e \u0430\u043d\u0430\u043b\u0438\u0437\u0430 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u043d\u0430 \u043f\u0430\u043d\u0435\u043b\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, <a href=\"https:\/\/shieldhz.com\/\" target=\"_blank\" rel=\"noopener\">\u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b \u0441\u0438\u0441\u0442\u0435\u043c \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/a> \u0442\u0430\u043a\u0438\u0435 \u043a\u0430\u043a \u0441\u0435\u043b\u0435\u043a\u0442\u043e\u0440\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438, \u0441\u0438\u0433\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u043b\u0430\u043c\u043f\u044b, \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b, \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0442\u044c \u0432\u043c\u0435\u0441\u0442\u0435 \u0441 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u043c\u0438 \u043a\u043e\u043b\u043e\u0434\u043a\u0430\u043c\u0438 \u0438 \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u043a\u0430\u043d\u0430\u043b\u0430\u043c\u0438, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0441\u0445\u0435\u043c\u0430 \u043f\u0440\u043e\u043a\u043b\u0430\u0434\u043a\u0438 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0438 \u0432\u044b\u0431\u043e\u0440 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u043e\u0432 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430 \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u0430 \u0432\u0437\u0430\u0438\u043c\u043d\u043e \u0432\u043b\u0438\u044f\u044e\u0442 \u0434\u0440\u0443\u0433 \u043d\u0430 \u0434\u0440\u0443\u0433\u0430.<\/p>\n<p><strong>\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0438\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0438 \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/strong> \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u0442\u044c:<br \/>\n- \u041f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u043d\u0430\u043f\u0435\u0447\u0430\u0442\u0430\u043d\u043d\u044b\u0435 \u043c\u0430\u0440\u043a\u0435\u0440\u044b \u0434\u043b\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u043e\u0432<br \/>\n- \u042d\u0442\u0438\u043a\u0435\u0442\u043a\u0438 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a<br \/>\n- \u041a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u0431\u0438\u0440\u043a\u0438 \u0438 \u043d\u0430\u043a\u043e\u043d\u0435\u0447\u043d\u0438\u043a\u0438<br \/>\n- \u0421\u0438\u0441\u0442\u0435\u043c\u044b \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0441 \u043b\u0430\u0437\u0435\u0440\u043d\u043e\u0439 \u043f\u0435\u0447\u0430\u0442\u044c\u044e<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear.webp\" alt=\"\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0446\u0430 \u0432\u0435\u0434\u0443\u0449\u0438\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0430 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0438 \u0442\u0438\u043f\u0430 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f\" class=\"wp-image-3688\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-02-terminal-block-manufacturer-comparison-table-switchgear-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u0442\u0430\u0431\u043b\u0438\u0446\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u043e \u043f\u044f\u0442\u0438 \u0432\u0435\u0434\u0443\u0449\u0438\u043c \u0441\u0435\u0440\u0438\u044f\u043c \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438.<\/figcaption><\/figure>\n<h2>\u041b\u0443\u0447\u0448\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432<\/h2>\n<h3>\u0424\u0435\u043d\u0438\u043a\u0441 \u041a\u043e\u043d\u0442\u0430\u043a\u0442<\/h3>\n<p>Phoenix Contact \u043d\u0435\u0438\u0437\u043c\u0435\u043d\u043d\u043e \u0437\u0430\u043d\u0438\u043c\u0430\u0435\u0442 \u043f\u0435\u0440\u0432\u043e\u0435 \u043c\u0435\u0441\u0442\u043e \u0441\u0440\u0435\u0434\u0438 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0432\u043e \u0432\u0441\u0435\u043c \u043c\u0438\u0440\u0435. \u0418\u0445 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430 CLIPLINE \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442:<\/p>\n<ul>\n<li><strong>\u0411\u0440\u0438\u0442\u0430\u043d\u0441\u043a\u0430\u044f \u0441\u0435\u0440\u0438\u044f<\/strong> \u043f\u0440\u043e\u0445\u043e\u0434\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c \u0434\u043e 1000\u0412\/125\u0410<\/li>\n<li><strong>\u0421\u0435\u0440\u0438\u044f UT<\/strong> \u0434\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c\u044e \u0440\u0430\u0437\u043c\u0435\u0449\u0435\u043d\u0438\u044f, \u0442\u0440\u0435\u0431\u0443\u044e\u0449\u0438\u0445 \u043c\u0435\u043d\u044c\u0448\u0438\u0445 \u0433\u0430\u0431\u0430\u0440\u0438\u0442\u043e\u0432<\/li>\n<li><strong>\u0421\u0435\u0440\u0438\u044f PT<\/strong> \u0422\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f push-in \u0441\u043e\u043a\u0440\u0430\u0449\u0430\u0435\u0442 \u0432\u0440\u0435\u043c\u044f \u043c\u043e\u043d\u0442\u0430\u0436\u0430 \u043f\u0440\u0438\u043c\u0435\u0440\u043d\u043e \u043d\u0430 50%<\/li>\n<li><strong>\u041e\u0431\u0448\u0438\u0440\u043d\u044b\u0439 \u043f\u043e\u0440\u0442\u0444\u0435\u043b\u044c \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0432<\/strong> \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0440\u0435\u0439\u0442\u0438\u043d\u0433\u0438 UL 1059, CSA, ATEX \u0438 IECEx<\/li>\n<\/ul>\n<p>\u0412 \u043d\u0435\u0434\u0430\u0432\u043d\u0435\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 15 \u043a\u0412 \u0434\u043b\u044f \u0446\u0435\u043d\u0442\u0440\u0430 \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0438 \u0434\u0430\u043d\u043d\u044b\u0445 \u043c\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043b\u0438 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b PTIO \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 Phoenix Contact. \u0411\u0435\u0437\u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u0432\u0441\u0442\u0430\u0432\u043d\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435 \u0432 \u0441\u043e\u0447\u0435\u0442\u0430\u043d\u0438\u0438 \u0441 \u0444\u0443\u043d\u043a\u0446\u0438\u0435\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438\/\u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0441\u043e\u043a\u0440\u0430\u0442\u0438\u043b\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0430\u043d\u0435\u043b\u0438 \u0441 18 \u0447\u0430\u0441\u043e\u0432 \u0434\u043e \u043f\u0440\u0438\u043c\u0435\u0440\u043d\u043e 11 \u0447\u0430\u0441\u043e\u0432 \u043d\u0430 \u0441\u0435\u043a\u0446\u0438\u044e \u043b\u0438\u043d\u0438\u0438.<\/p>\n<h3>\u0412\u0430\u0439\u0434\u043c\u044e\u043b\u043b\u0435\u0440<\/h3>\n<p>\u041d\u0435\u043c\u0435\u0446\u043a\u0430\u044f \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u0430\u044f \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0430\u0441\u0441\u043e\u0440\u0442\u0438\u043c\u0435\u043d\u0442 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a Weidm\u00fcller. \u0421\u0435\u0440\u0438\u044f KLIPPON Connect \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442:<\/p>\n<ul>\n<li><strong>\u0422\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f SNAP IN<\/strong> \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432\u0441\u043b\u0435\u043f\u0443\u044e, \u0447\u0442\u043e \u043e\u0447\u0435\u043d\u044c \u0432\u0430\u0436\u043d\u043e \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0442\u0435 \u0432 \u0437\u0430\u043a\u0440\u044b\u0442\u044b\u0445 \u043e\u0442\u0441\u0435\u043a\u0430\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432<\/li>\n<li><strong>\u0421\u0435\u0440\u0438\u044f W<\/strong> \u041a\u043b\u0435\u043c\u043c\u044b \u0441 \u0435\u043c\u043a\u043e\u0441\u0442\u044c\u044e \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432 2,5-35 \u043c\u043c\u00b2<\/li>\n<li><strong>\u0428\u0438\u0440\u043e\u043a\u0438\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0446\u0432\u0435\u0442\u043e\u0432\u043e\u0433\u043e \u043a\u043e\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f<\/strong> \u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c IEC 60446<\/li>\n<li><strong>\u041a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u0442\u0435\u043d\u0434\u044b<\/strong> \u043d\u0430 \u043a\u043b\u0435\u043c\u043c\u0430\u0445 \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u0438\u043f\u0430<\/li>\n<\/ul>\n<h3>\u0412\u0430\u0433\u043e<\/h3>\n<p>\u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Wago \u043f\u0440\u043e\u0438\u0437\u0432\u0435\u043b\u0430 \u0440\u0435\u0432\u043e\u043b\u044e\u0446\u0438\u044e \u0432 \u043e\u0442\u0440\u0430\u0441\u043b\u0438, \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u0432 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044e \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u0441 \u0441\u0435\u043f\u0430\u0440\u0430\u0442\u043e\u0440\u043d\u044b\u043c \u0437\u0430\u0436\u0438\u043c\u043e\u043c. \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u044b \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:<\/p>\n<ul>\n<li><strong>\u0421\u0435\u0440\u0438\u044f TOPJOB S<\/strong> \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d \u043d\u0430 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0445 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/li>\n<li><strong>\u0421\u0435\u0440\u0438\u044f 2000<\/strong> \u0423\u043b\u044c\u0442\u0440\u0430\u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u043e\u0435 \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 3,5 \u043c\u043c<\/li>\n<li><strong>\u0420\u0430\u0431\u043e\u0442\u0430 \u0431\u0435\u0437 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u043e\u0432<\/strong> \u0443\u043c\u0435\u043d\u044c\u0448\u0435\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043e\u043a \u043f\u0440\u0438 \u043c\u043e\u043d\u0442\u0430\u0436\u0435 \u0438\u0437-\u0437\u0430 \u0447\u0440\u0435\u0437\u043c\u0435\u0440\u043d\u043e \u0437\u0430\u0442\u044f\u043d\u0443\u0442\u044b\u0445 \u0432\u0438\u043d\u0442\u043e\u0432<\/li>\n<li><strong>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438<\/strong> \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0449\u0438\u0435 \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b - \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u043e \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u043f\u043e\u0434\u0432\u0435\u0440\u0436\u0435\u043d\u043d\u044b\u0445 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0430\u043c<\/li>\n<\/ul>\n<h3>ABB Entrelec<\/h3>\n<p>\u041f\u043e\u0434\u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0410\u0411\u0411 Entrelec \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438, \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u0438\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u0438 \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430:<\/p>\n<ul>\n<li><strong>\u0421\u0435\u0440\u0438\u044f SNK<\/strong> \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u044b\u043c\u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438<\/li>\n<li><strong>\u0421\u0435\u0440\u0438\u044f MA2.5<\/strong> \u0418\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c \u0434\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0440\u0435\u043b\u0435\u0439\u043d\u043e\u0439 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0438<\/li>\n<li><strong>\u041f\u0440\u044f\u043c\u0430\u044f \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c<\/strong> \u0441 \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b \u0438 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f ABB<\/li>\n<\/ul>\n<h3>Rockwell Automation (Allen-Bradley)<\/h3>\n<p>\u0414\u043b\u044f \u0441\u0435\u0432\u0435\u0440\u043e\u0430\u043c\u0435\u0440\u0438\u043a\u0430\u043d\u0441\u043a\u0438\u0445 \u0440\u044b\u043d\u043a\u043e\u0432 \u0438 \u043e\u0431\u044a\u0435\u043a\u0442\u043e\u0432, \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043d\u0430 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u0430\u0445 Rockwell:<\/p>\n<ul>\n<li><strong>\u0421\u0435\u0440\u0438\u044f 1492<\/strong> \u041a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0441 \u043e\u0431\u0448\u0438\u0440\u043d\u044b\u043c\u0438 \u0441\u043f\u0438\u0441\u043a\u0430\u043c\u0438 UL<\/li>\n<li><strong>\u0413\u043e\u0442\u043e\u0432\u044b\u0435 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u044b\u0435 \u0440\u0435\u0448\u0435\u043d\u0438\u044f<\/strong> \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432 \u043f\u043e\u043b\u0435\u0432\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445<\/li>\n<li><strong>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0441\u043e Studio 5000<\/strong> \u0434\u043b\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u043e\u0431\u043e\u0440\u043e\u0442\u0430<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear.webp\" alt=\"\u0411\u043b\u043e\u043a-\u0441\u0445\u0435\u043c\u0430 \u0432\u044b\u0431\u043e\u0440\u0430 \u0442\u0438\u043f\u0430 \u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u0430 \u043a\u043b\u0435\u043c\u043c\u043d\u043e\u0439 \u043a\u043e\u043b\u043e\u0434\u043a\u0438 \u0434\u043b\u044f \u0446\u0435\u043f\u0435\u0439 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\" class=\"wp-image-3689\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-03-terminal-block-selection-flowchart-switchgear-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0421\u0445\u0435\u043c\u0430 \u0432\u044b\u0431\u043e\u0440\u0430 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u0442\u0438\u043f\u0430 \u0446\u0435\u043f\u0438, \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044f \u0442\u043e\u043a\u0430 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u043c \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u043c.<\/figcaption><\/figure>\n<h2>\u0410\u043d\u0430\u043b\u0438\u0437 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0438 \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c<\/h2>\n<h3>Panduit<\/h3>\n<p>\u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Panduit \u0434\u043e\u043c\u0438\u043d\u0438\u0440\u0443\u0435\u0442 \u043d\u0430 \u0441\u0435\u0432\u0435\u0440\u043e\u0430\u043c\u0435\u0440\u0438\u043a\u0430\u043d\u0441\u043a\u043e\u043c \u0440\u044b\u043d\u043a\u0435 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u0441\u0432\u043e\u0435\u0439 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438:<\/p>\n<ul>\n<li><strong>\u0429\u0435\u043b\u0435\u0432\u043e\u0439 \u0432\u043e\u0437\u0434\u0443\u0445\u043e\u0432\u043e\u0434 \u0442\u0438\u043f\u0430 F\/G\/H<\/strong> \u0432 \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f\u0445 \u043f\u0430\u043b\u044c\u0446\u0435\u0432<\/li>\n<li><strong>PANDUCT\u00ae \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0439 \u043a\u0430\u043d\u0430\u043b<\/strong> \u0441 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0435\u043c \u0441\u043b\u043e\u0442\u043e\u0432<\/li>\n<li><strong>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b \u0438\u0437 \u041f\u0412\u0425 \u0438 \u041f\u0412\u0414\u0424<\/strong> \u0434\u043b\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0445 \u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u044b\u0445 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0439<\/li>\n<li><strong>\u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0434\u043b\u044f \u0443\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u044f \u043a\u0440\u044b\u0448\u043a\u0438<\/strong> \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u043e\u0433\u043e \u043e\u0442\u043a\u0440\u044b\u0442\u0438\u044f<\/li>\n<\/ul>\n<p>\u042f \u0432\u044b\u0431\u0440\u0430\u043b \u0432\u043e\u0437\u0434\u0443\u0445\u043e\u0432\u043e\u0434 Panduit \u0442\u0438\u043f\u0430 G (\u0443\u0437\u043a\u0430\u044f \u0449\u0435\u043b\u044c, \u0448\u0438\u0440\u043e\u043a\u0438\u0439 \u043f\u0430\u043b\u0435\u0446) \u0438\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0434\u043b\u044f \u043f\u0440\u043e\u043a\u043b\u0430\u0434\u043a\u0438 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0441\u0438\u0433\u043d\u0430\u043b\u043e\u0432 \u0432 \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043e\u0442\u0441\u0435\u043a\u0430\u0445 - \u0443\u0437\u043a\u0438\u0435 \u0449\u0435\u043b\u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044e\u0442 \u0441\u043b\u0443\u0447\u0430\u0439\u043d\u043e\u0435 \u0438\u0437\u0432\u043b\u0435\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0432\u043e\u0434\u043e\u0432, \u0441\u043e\u0445\u0440\u0430\u043d\u044f\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c.<\/p>\n<h3>HellermannTyton<\/h3>\n<p>HellermannTyton \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442 \u0438\u0441\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u0446\u0435\u043d\u043d\u043e\u0441\u0442\u044c:<\/p>\n<ul>\n<li><strong>\u0421\u0435\u0440\u0438\u044f HTWD<\/strong> \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u0430\u043d\u0430\u043b\u044b \u043c\u0435\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 \u0438\u043c\u043f\u0435\u0440\u0441\u043a\u0438\u0445 \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432<\/li>\n<li><strong>\u0412\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u043f\u043b\u043e\u0442\u043d\u043e\u0441\u0442\u044c\u044e \u043f\u0430\u0437\u043e\u0432<\/strong> \u0434\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0441\u0442\u0435\u043f\u0435\u043d\u044c\u044e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f<\/li>\n<li><strong>\u0411\u0435\u0437\u0433\u0430\u043b\u043e\u0433\u0435\u043d\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b<\/strong> \u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c EN 50642<\/li>\n<\/ul>\n<h3>Iboco (\u0440\u0430\u043d\u0435\u0435 T1 Group)<\/h3>\n<p>\u0415\u0432\u0440\u043e\u043f\u0435\u0439\u0441\u043a\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0447\u0430\u0441\u0442\u043e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u044e Iboco:<\/p>\n<ul>\n<li><strong>\u0421\u0435\u0440\u0438\u044f CD-HF<\/strong> \u0432\u043e\u0437\u0434\u0443\u0445\u043e\u0432\u043e\u0434 \u0431\u0435\u0437 \u0433\u0430\u043b\u043e\u0433\u0435\u043d\u043e\u0432, \u043e\u0442\u0432\u0435\u0447\u0430\u044e\u0449\u0438\u0439 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438<\/li>\n<li><strong>\u0411\u044b\u0441\u0442\u0440\u043e\u043c\u043e\u043d\u0442\u0438\u0440\u0443\u0435\u043c\u044b\u0435 \u0431\u0430\u0437\u043e\u0432\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/strong> \u0441\u043e\u043a\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0441\u0431\u043e\u0440\u043a\u0438 \u043f\u0430\u043d\u0435\u043b\u0435\u0439<\/li>\n<li><strong>\u0428\u0438\u0440\u043e\u043a\u0438\u0439 \u0432\u044b\u0431\u043e\u0440 \u0430\u043a\u0441\u0435\u0441\u0441\u0443\u0430\u0440\u043e\u0432<\/strong> \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0443\u0433\u043b\u044b, \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u044b \u0438 \u0442\u043e\u0440\u0446\u0435\u0432\u044b\u0435 \u0437\u0430\u0433\u043b\u0443\u0448\u043a\u0438<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel.webp\" alt=\"\u0421\u0445\u0435\u043c\u0430 \u043f\u043e\u043f\u0435\u0440\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0447\u0435\u043d\u0438\u044f \u043e\u0442\u0441\u0435\u043a\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0430\u044f \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0434\u043b\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u043e\u0432 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e, \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0438 \u0441\u0438\u0433\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430\" class=\"wp-image-3690\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/fig-04-control-wiring-duct-routing-switchgear-panel-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0421\u0445\u0435\u043c\u0430 \u043f\u0440\u043e\u043a\u043b\u0430\u0434\u043a\u0438 \u043a\u0430\u0431\u0435\u043b\u044c\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0432 \u043e\u0442\u0441\u0435\u043a\u0435 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0438\u0440\u0443\u044e\u0449\u0430\u044f \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0446\u0435\u043f\u0435\u0439 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u043c \u0442\u043e\u043a\u043e\u043c, \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u043c \u0442\u043e\u043a\u043e\u043c \u0438 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0441\u0438\u0433\u043d\u0430\u043b\u043e\u0432.<\/figcaption><\/figure>\n<h2>\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043e\u0442\u0431\u043e\u0440\u0430 \u0438 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u0441\u043f\u0438\u0441\u043e\u043a<\/h2>\n<h3>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044b<\/h3>\n<p>\u041f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u0431\u043b\u043e\u043a\u043e\u0432 \u0434\u043b\u044f \u0446\u0435\u043f\u0435\u0439 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0435<\/th>\n<th>\u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u0430\u044f \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td>300 \u0412 (UL) \/ 500 \u0412 (IEC)<\/td>\n<td>600 \u0412 (UL) \/ 800 \u0412 (IEC)<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0446\u0435\u043f\u0438 \u00d7 1,25<\/td>\n<td>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0446\u0435\u043f\u0438 \u00d7 1,5<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/td>\n<td>\u041a\u043e\u043e\u0440\u0434\u0438\u043d\u0438\u0440\u0443\u0439\u0442\u0435 \u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0441 \u0437\u0430\u0449\u0438\u0442\u043e\u0439 \u0432\u044b\u0448\u0435 \u043f\u043e \u0442\u0435\u0447\u0435\u043d\u0438\u044e<\/td>\n<td>\u041f\u0440\u0435\u0440\u044b\u0432\u0430\u0442\u0435\u043b\u044c\/\u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c \u043f\u0440\u043e\u0445\u043e\u0434\u043d\u043e\u0439<\/td>\n<\/tr>\n<tr>\n<td>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u0430\u043c<\/td>\n<td>2,5 \u043a\u0412 \u043c\u0438\u043d\u0438\u043c\u0443\u043c<\/td>\n<td>4 \u043a\u0412 \u0434\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u043e\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f<\/h3>\n<p>\u0421\u0440\u0435\u0434\u0430 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0441\u043e\u0431\u043e\u0439 \u0443\u043d\u0438\u043a\u0430\u043b\u044c\u043d\u0443\u044e \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0443:<\/p>\n<p><strong>\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u044b\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0438<\/strong> \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0443\u0447\u0442\u0435\u043d\u044b:<br \/>\n- \u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b (\u0447\u0430\u0441\u0442\u043e 40\u00b0C \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEEE C37.20.2)<br \/>\n- \u041f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b (\u043e\u0431\u044b\u0447\u043d\u043e \u043d\u0430 15-25\u00b0C)<br \/>\n- \u0422\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u0432\u043a\u043b\u0430\u0434 \u043e\u0442 \u0441\u043e\u0441\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f<\/p>\n<p>\u0414\u043b\u044f \u043d\u0430\u0440\u0443\u0436\u043d\u044b\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0432 \u043f\u0443\u0441\u0442\u044b\u043d\u043d\u043e\u043c \u043a\u043b\u0438\u043c\u0430\u0442\u0435 \u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043b \u043a\u043b\u0435\u043c\u043c\u044b, \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u043d\u044b\u0435 \u043d\u0430 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u0443\u044e \u0440\u0430\u0431\u043e\u0442\u0443 \u043f\u0440\u0438 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0435 105\u00b0C - \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 85\u00b0C \u043f\u0440\u0438\u0432\u0435\u043b\u0438 \u0431\u044b \u043a \u0440\u0430\u0437\u0440\u0443\u0448\u0435\u043d\u0438\u044e \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 2-3 \u043b\u0435\u0442.<\/p>\n<p><strong>\u0423\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f\u043c \u0438 \u0443\u0434\u0430\u0440\u0430\u043c<\/strong> \u0438\u043c\u0435\u0435\u0442 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 \u0434\u043b\u044f:<br \/>\n- \u0421\u0435\u0439\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f (\u043a\u0432\u0430\u043b\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f IEEE 693)<br \/>\n- \u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432\u0431\u043b\u0438\u0437\u0438 \u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0438\u0445\u0441\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u043e\u0432<br \/>\n- \u041c\u043e\u0431\u0438\u043b\u044c\u043d\u044b\u0435 \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u043d\u043e\u0441\u043d\u044b\u0435 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438<\/p>\n<h3>\u0412\u044b\u0431\u043e\u0440 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430<\/h3>\n<p><strong>\u041a\u043e\u0440\u043f\u0443\u0441\u0430 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a:<\/strong><br \/>\n\u2013 <strong>\u041f\u043e\u043b\u0438\u0430\u043c\u0438\u0434 (PA6.6)<\/strong> \u041e\u0431\u043b\u0430\u0434\u0430\u0435\u0442 \u043e\u0442\u043b\u0438\u0447\u043d\u043e\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c\u044e \u0438 \u0442\u0435\u0440\u043c\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c\u044e<br \/>\n\u2013 <strong>\u041f\u043e\u043b\u0438\u043a\u0430\u0440\u0431\u043e\u043d\u0430\u0442<\/strong> \u041e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u043f\u0440\u0435\u0432\u043e\u0441\u0445\u043e\u0434\u043d\u0443\u044e \u0443\u0434\u0430\u0440\u043e\u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c, \u043d\u043e \u0438\u043c\u0435\u0435\u0442 \u0431\u043e\u043b\u0435\u0435 \u043d\u0438\u0437\u043a\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u044b\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0438<br \/>\n\u2013 <strong>\u041a\u0435\u0440\u0430\u043c\u0438\u043a\u0430<\/strong> \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u044d\u043a\u0441\u0442\u0440\u0435\u043c\u0430\u043b\u044c\u043d\u043e \u0432\u044b\u0441\u043e\u043a\u0438\u0445 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430\u0445 \u0438\u043b\u0438 \u0432 \u043f\u043e\u0436\u0430\u0440\u043e\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445<\/p>\n<p><strong>\u0422\u0435\u043a\u0443\u0449\u0438\u0435 \u0431\u0430\u0440\u044b \u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b:<\/strong><br \/>\n\u2013 <strong>\u041b\u0430\u0442\u0443\u043d\u044c<\/strong> \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0445\u043e\u0440\u043e\u0448\u0443\u044e \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u0443\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0439 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438<br \/>\n\u2013 <strong>\u041c\u0435\u0434\u044c<\/strong> \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u0441\u0438\u043b\u044c\u043d\u043e\u0442\u043e\u0447\u043d\u044b\u0445 \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439<br \/>\n\u2013 <strong>\u041e\u043b\u043e\u0432\u044f\u043d\u043d\u043e\u0435 \u0438\u043b\u0438 \u043d\u0438\u043a\u0435\u043b\u0435\u0432\u043e\u0435 \u043f\u043e\u043a\u0440\u044b\u0442\u0438\u0435<\/strong> \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u044e \u0432 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445<\/p>\n<h3>\u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044e<\/h3>\n<p>\u0412\u0441\u0435\u0433\u0434\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u0439\u0442\u0435:<br \/>\n\u2013 <strong>UL 1059<\/strong> \u0441\u043f\u0438\u0441\u043e\u043a \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432 \u0421\u0435\u0432\u0435\u0440\u043d\u043e\u0439 \u0410\u043c\u0435\u0440\u0438\u043a\u0435<br \/>\n\u2013 <strong>IEC 60947-7-1<\/strong> \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u044b\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0430\u043c<br \/>\n\u2013 <strong>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f CSA<\/strong> \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432 \u041a\u0430\u043d\u0430\u0434\u0435<br \/>\n\u2013 <strong>ATEX\/IECEx<\/strong> \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043e \u0432\u0437\u0440\u044b\u0432\u043e\u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0437\u043e\u043d\u0430\u0445<br \/>\n\u2013 <strong>UL 508A<\/strong> \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0434\u043b\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/p>\n<hr \/>\n<h2>\u041f\u0435\u0440\u0435\u0434\u043e\u0432\u044b\u0435 \u043c\u0435\u0442\u043e\u0434\u044b \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438<\/h2>\n<h3>\u0421\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a<\/h3>\n<p>\u041f\u043e\u0441\u043b\u0435 \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044f \u0441\u043e\u0442\u0435\u043d \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0449\u0438\u0442\u043e\u0432 \u044f \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043b \u044d\u0442\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u0435 \u043c\u0435\u0442\u043e\u0434\u044b \u043a\u043e\u043c\u043f\u043e\u043d\u043e\u0432\u043a\u0438:<\/p>\n<p><strong>\u0424\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0433\u0440\u0443\u043f\u043f\u0438\u0440\u043e\u0432\u043a\u0430:<\/strong><br \/>\n1. \u0413\u0440\u0443\u043f\u043f\u0438\u0440\u0443\u0439\u0442\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u043f\u043e \u0444\u0443\u043d\u043a\u0446\u0438\u044f\u043c \u0446\u0435\u043f\u0438 (\u0437\u0430\u0449\u0438\u0442\u0430, \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435, \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435, \u0441\u0432\u044f\u0437\u044c)<br \/>\n2. \u0421\u043e\u0431\u043b\u044e\u0434\u0430\u0439\u0442\u0435 \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u0446\u0435\u043f\u044f\u043c\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0438 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (\u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u0442\u0441\u044f \u043d\u0435 \u043c\u0435\u043d\u0435\u0435 50 \u043c\u043c).<br \/>\n3. \u0420\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0438\u0442\u0435 \u0447\u0430\u0441\u0442\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u0435 \u0442\u0435\u0441\u0442\u043e\u0432\u044b\u0435 \u0442\u0435\u0440\u043c\u0438\u043d\u0430\u043b\u044b \u043d\u0430 \u044d\u0440\u0433\u043e\u043d\u043e\u043c\u0438\u0447\u043d\u043e\u0439 \u0432\u044b\u0441\u043e\u0442\u0435<\/p>\n<p><strong>\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u043a\u043b\u0435\u043c\u043c:<\/strong><br \/>\n- \u041e\u0431\u0435\u0441\u043f\u0435\u0447\u044c\u0442\u0435 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b 15-20% \u0434\u043b\u044f \u0431\u0443\u0434\u0443\u0449\u0438\u0445 \u043c\u043e\u0434\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0439<br \/>\n- \u0413\u0440\u0443\u043f\u043f\u0438\u0440\u043e\u0432\u043a\u0430 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u0432 \u043a\u043e\u043d\u0446\u0435 \u043a\u0430\u0436\u0434\u043e\u0439 \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u0441\u0435\u043a\u0446\u0438\u0438<br \/>\n- \u041f\u0440\u0435\u0434\u0432\u0430\u0440\u0438\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u043a\u0430\u043a \u201cSPARE\u201d \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f<\/p>\n<h3>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043a\u0440\u0443\u0442\u044f\u0449\u0435\u0433\u043e \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u0438 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439<\/h3>\n<p>\u041d\u0435\u0438\u0441\u043f\u0440\u0430\u0432\u043d\u043e\u0441\u0442\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u0447\u0430\u0441\u0442\u043e \u0441\u0432\u044f\u0437\u0430\u043d\u044b \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043c\u043e\u043c\u0435\u043d\u0442\u043e\u043c \u0437\u0430\u0442\u044f\u0436\u043a\u0438. \u0417\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u0443\u0439\u0442\u0435 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435:<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0420\u0430\u0437\u043c\u0435\u0440 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u0430 (AWG)<\/th>\n<th>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0439 \u043a\u0440\u0443\u0442\u044f\u0449\u0438\u0439 \u043c\u043e\u043c\u0435\u043d\u0442 (\u0444\u0443\u043d\u0442-\u0434\u044e\u0439\u043c)<\/th>\n<th>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0439 \u043a\u0440\u0443\u0442\u044f\u0449\u0438\u0439 \u043c\u043e\u043c\u0435\u043d\u0442 (\u041d\u043c)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>18-16<\/td>\n<td>4.4-5.3<\/td>\n<td>0.5-0.6<\/td>\n<\/tr>\n<tr>\n<td>14-12<\/td>\n<td>7.1-8.8<\/td>\n<td>0.8-1.0<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>17.7-22.1<\/td>\n<td>2.0-2.5<\/td>\n<\/tr>\n<tr>\n<td>8-6<\/td>\n<td>26.5-35.4<\/td>\n<td>3.0-4.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0421\u043e\u0432\u0435\u0442: \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0434\u0438\u043d\u0430\u043c\u043e\u043c\u0435\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043e\u0442\u0432\u0435\u0440\u0442\u043a\u0438 \u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u0443\u0439\u0442\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043a\u0440\u0443\u0442\u044f\u0449\u0435\u0433\u043e \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u0432 \u0441\u043f\u0438\u0441\u043a\u0430\u0445 \u043f\u0443\u0441\u043a\u043e\u043d\u0430\u043b\u0430\u0434\u043e\u0447\u043d\u044b\u0445 \u0440\u0430\u0431\u043e\u0442. \u042f \u0437\u0430\u0431\u0440\u0430\u043a\u043e\u0432\u0430\u043b \u0446\u0435\u043b\u044b\u0435 \u043f\u0430\u0440\u0442\u0438\u0438 \u043f\u0430\u043d\u0435\u043b\u0435\u0439, \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0432 \u043f\u0440\u0438 \u043f\u0440\u0438\u0435\u043c\u043a\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043a\u0440\u0443\u0442\u044f\u0449\u0435\u0433\u043e \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u043d\u0430 30-40% \u043d\u0438\u0436\u0435 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438.<\/p>\n<h3>\u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0445 \u0444\u0435\u0440\u0443\u043b<\/h3>\n<p>\u0424\u0435\u0440\u0440\u0443\u043b\u044b \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u043f\u043e\u0432\u044b\u0448\u0430\u044e\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f, \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u043f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u043c\u043d\u043e\u0433\u043e\u0436\u0438\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432:<\/p>\n<ul>\n<li><strong>\u0412\u0441\u0435\u0433\u0434\u0430 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043d\u0430\u043a\u043e\u043d\u0435\u0447\u043d\u0438\u043a\u0438<\/strong> \u0441 \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u043c \u0437\u0430\u0436\u0438\u043c\u043e\u043c \u0438 \u0432\u0441\u0442\u0430\u0432\u043d\u044b\u043c\u0438 \u043a\u043b\u0435\u043c\u043c\u0430\u043c\u0438<\/li>\n<li><strong>\u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u043c \u0444\u0435\u0440\u0440\u0443\u043b\u044b<\/strong> \u0441 \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u043c\u0438 \u0437\u0430\u0436\u0438\u043c\u0430\u043c\u0438 \u0434\u043b\u044f \u043c\u043d\u043e\u0433\u043e\u0436\u0438\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0432\u043e\u0434\u0430<\/li>\n<li><strong>\u0412\u044b\u0431\u0435\u0440\u0438\u0442\u0435 \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043d\u0430\u043a\u043e\u043d\u0435\u0447\u043d\u0438\u043a\u0438<\/strong> \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u043f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0435\u0433\u043e \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u0430<\/li>\n<li><strong>\u0426\u0432\u0435\u0442\u043e\u0432\u0430\u044f \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0444\u0435\u0440\u0440\u0443\u043b\u043e\u0432<\/strong> \u043f\u043e DIN 46228-4 \u0434\u043b\u044f \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0440\u0430\u0437\u043c\u0435\u0440\u0430<\/li>\n<\/ul>\n<hr \/>\n<h2>\u0410\u043d\u0430\u043b\u0438\u0437 \u0437\u0430\u0442\u0440\u0430\u0442 \u0438 \u0432\u044b\u0433\u043e\u0434 \u0438 \u0441\u0442\u0440\u0430\u0442\u0435\u0433\u0438\u0438 \u0437\u0430\u043a\u0443\u043f\u043e\u043a<\/h2>\n<h3>\u041f\u0435\u0440\u0441\u043f\u0435\u043a\u0442\u0438\u0432\u0430 \u0441\u043e\u0432\u043e\u043a\u0443\u043f\u043d\u043e\u0439 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u0438 \u0432\u043b\u0430\u0434\u0435\u043d\u0438\u044f<\/h3>\n<p>\u0425\u043e\u0442\u044f \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u043c\u043e\u0433\u0443\u0442 \u0441\u0442\u043e\u0438\u0442\u044c \u043d\u0430 40-60% \u0434\u0435\u0448\u0435\u0432\u043b\u0435, \u0447\u0435\u043c \u043f\u0440\u0435\u043c\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0431\u0440\u0435\u043d\u0434\u044b, \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0439\u0442\u0435 \u044d\u0442\u043e:<\/p>\n<p><strong>\u041f\u0440\u044f\u043c\u044b\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043e\u0442\u043a\u0430\u0437:<\/strong><br \/>\n- \u0420\u0430\u0441\u0445\u043e\u0434\u044b \u043d\u0430 \u043d\u0435\u0437\u0430\u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u043f\u0440\u043e\u0441\u0442\u043e\u0439 ($10,000-$100,000+ \u0432 \u0447\u0430\u0441 \u043d\u0430 \u043a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u0430\u0436\u043d\u044b\u0445 \u043e\u0431\u044a\u0435\u043a\u0442\u0430\u0445)<br \/>\n- \u041f\u043b\u0430\u0442\u0430 \u0437\u0430 \u0432\u044b\u0437\u043e\u0432 \u0430\u0432\u0430\u0440\u0438\u0439\u043d\u043e\u0439 \u0441\u043b\u0443\u0436\u0431\u044b<br \/>\n- \u0423\u0441\u043a\u043e\u0440\u0435\u043d\u043d\u0430\u044f \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u0430 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439<\/p>\n<p><strong>\u041a\u043e\u0441\u0432\u0435\u043d\u043d\u044b\u0435 \u0437\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e:<\/strong><br \/>\n- \u0423\u0432\u0435\u043b\u0438\u0447\u0435\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0432\u0432\u043e\u0434\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043f\u0440\u0438 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432<br \/>\n- \u0411\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u0438\u0435 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0438 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0439\u043d\u044b\u0445 \u0440\u0435\u043a\u043b\u0430\u043c\u0430\u0446\u0438\u0439<br \/>\n- \u0423\u0449\u0435\u0440\u0431 \u0440\u0435\u043f\u0443\u0442\u0430\u0446\u0438\u0438 \u0432 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u0435 \u043d\u0435\u0443\u0434\u0430\u0447 \u043d\u0430 \u043c\u0435\u0441\u0442\u0430\u0445<\/p>\n<p>\u041f\u0440\u0438 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0438 \u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u043c\u044b \u043f\u043e\u0434\u0441\u0447\u0438\u0442\u0430\u043b\u0438, \u0447\u0442\u043e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u043b\u0435\u043c\u043c Phoenix Contact \u0432 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0438 \u0441 \u043d\u0435\u0434\u043e\u0440\u043e\u0433\u043e\u0439 \u0430\u043b\u044c\u0442\u0435\u0440\u043d\u0430\u0442\u0438\u0432\u043e\u0439 \u0443\u0432\u0435\u043b\u0438\u0447\u0438\u043b\u043e \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432 \u0434\u043b\u044f 8-\u0441\u0435\u043a\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u043b\u0438\u043d\u0438\u0438 15 \u043a\u0412 \u043d\u0430 $3 200. \u042d\u0442\u043e\u0442 \u0436\u0435 \u043f\u0440\u043e\u0435\u043a\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u043b \u0438\u0437\u0431\u0435\u0436\u0430\u0442\u044c $180 000 \u043f\u043e\u0442\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0437\u0430\u0442\u0440\u0430\u0442 \u043d\u0430 \u043e\u0442\u043a\u0430\u0437 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 25-\u043b\u0435\u0442\u043d\u0435\u0433\u043e \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n<h3>\u0421\u043e\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f \u043f\u043e \u043f\u043e\u0432\u043e\u0434\u0443 \u043e\u0431\u044a\u0435\u043c\u043d\u044b\u0445 \u0437\u0430\u043a\u0443\u043f\u043e\u043a<\/h3>\n<p>\u0414\u043b\u044f \u043a\u0440\u0443\u043f\u043d\u044b\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0438\u043b\u0438 \u0442\u0435\u043a\u0443\u0449\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432:<\/p>\n<ul>\n<li>\u041f\u0435\u0440\u0435\u0433\u043e\u0432\u043e\u0440\u044b \u043e \u0440\u0430\u043c\u043e\u0447\u043d\u044b\u0445 \u0441\u043e\u0433\u043b\u0430\u0448\u0435\u043d\u0438\u044f\u0445 \u0441 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f\u043c\u0438 \u0434\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u0435\u0434\u0438\u043d\u044b\u0445 \u0446\u0435\u043d<\/li>\n<li>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u044d\u043a\u043e\u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u0438<\/li>\n<li>\u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c \u0443\u0441\u043b\u0443\u0433 \u043f\u043e \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044e \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0445 \u0441\u0440\u0435\u0434\u0441\u0442\u0432<\/li>\n<li>\u041e\u0446\u0435\u043d\u0438\u0442\u0435 \u043c\u0435\u0441\u0442\u043d\u044b\u0435 \u0437\u0430\u043f\u0430\u0441\u044b \u0438 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0434\u043e\u0441\u0442\u0430\u0432\u043a\u0438<\/li>\n<\/ul>\n<hr \/>\n<h2>\u041d\u043e\u0432\u044b\u0435 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0438 \u0438 \u0431\u0443\u0434\u0443\u0449\u0438\u0435 \u0441\u043e\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u044f<\/h2>\n<h3>\u0418\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438<\/h3>\n<p>\u041d\u0435\u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438 \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u044e\u0442 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0441\u043e \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u043c \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u043e\u043c:<\/p>\n<ul>\n<li><strong>\u0421\u0435\u0440\u0438\u044f PTCB \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u0438 Phoenix Contact<\/strong> \u0441\u043e \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u043c\u0438 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u0430\u043c\u0438 \u0442\u043e\u043a\u0430<\/li>\n<li><strong>\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0432\u0432\u043e\u0434\u0430\/\u0432\u044b\u0432\u043e\u0434\u0430 Wago<\/strong> \u043a\u043e\u043c\u0431\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0442\u0435\u0440\u043c\u0438\u043d\u0430\u043b\u043e\u0432 \u0441 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c\u044e \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u041f\u041b\u041a<\/li>\n<li><strong>\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f<\/strong> \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0435 \u043e\u0441\u043b\u0430\u0431\u043b\u0435\u043d\u043d\u044b\u0445 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u0433\u0440\u0435\u0432\u0430<\/li>\n<\/ul>\n<h3>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0432 \u0438\u043d\u0434\u0443\u0441\u0442\u0440\u0438\u044e 4.0<\/h3>\n<p>\u0421\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0432\u0441\u0435 \u0447\u0430\u0449\u0435 \u0442\u0440\u0435\u0431\u0443\u044e\u0442:<br \/>\n- \u041f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b \u0447\u0435\u0440\u0435\u0437 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0439 Ethernet<br \/>\n- \u0412\u043e\u043b\u043e\u043a\u043e\u043d\u043d\u043e-\u043e\u043f\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0434\u043b\u044f \u0446\u0435\u043f\u0435\u0439 \u0441\u0432\u044f\u0437\u0438<br \/>\n- \u042d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0434\u043b\u044f \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043a \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u043c \u043f\u043e\u043c\u0435\u0445\u0430\u043c \u0441\u0438\u0433\u043d\u0430\u043b\u043e\u0432<\/p>\n<p>\u0412\u043d\u0435\u0448\u043d\u044f\u044f \u0441\u0441\u044b\u043b\u043a\u0430: \u0410\u0441\u0441\u043e\u0446\u0438\u0430\u0446\u0438\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u0432 IEEE \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0432\u0441\u0435\u043e\u0431\u044a\u0435\u043c\u043b\u044e\u0449\u0435\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0441\u0438\u0441\u0442\u0435\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0432 \u0441\u0432\u043e\u0435\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0435 IEEE C37.2 \u0434\u043b\u044f \u043d\u043e\u043c\u0435\u0440\u043e\u0432 \u0444\u0443\u043d\u043a\u0446\u0438\u0439 \u0438 \u043e\u0431\u043e\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c, \u0447\u0442\u043e \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u0432\u043b\u0438\u044f\u0435\u0442 \u043d\u0430 \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0443 \u0438 \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u044e \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a.<\/p>\n<hr \/>\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<h3>Q1: \u041a\u0430\u043a\u043e\u0439 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043b\u0435\u043c\u043c\u043d\u043e\u0439 \u043a\u043e\u043b\u043e\u0434\u043a\u0438 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0443\u043a\u0430\u0437\u0430\u0442\u044c \u0434\u043b\u044f \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439 5A CT?<\/h3>\n<p>\u0414\u043b\u044f \u0432\u0442\u043e\u0440\u0438\u0447\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439 \u0422\u0422 \u044f \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u044e \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u043b\u0435\u043c\u043c\u044b \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c \u043d\u0435 \u043c\u0435\u043d\u0435\u0435 10 \u0410 \u0432 \u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u043e\u043c \u0440\u0435\u0436\u0438\u043c\u0435, \u043f\u0440\u0435\u0434\u043f\u043e\u0447\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u043e 15-20 \u0410. \u042d\u0442\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0437\u0430\u043f\u0430\u0441 \u043f\u043e \u0432\u043a\u043b\u0430\u0434\u0443 \u0432 \u0442\u043e\u043a \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0432\u043e\u0437\u043c\u0443\u0449\u0435\u043d\u0438\u044f\u0445. \u0427\u0442\u043e \u0435\u0449\u0435 \u0431\u043e\u043b\u0435\u0435 \u0432\u0430\u0436\u043d\u043e, \u0434\u043b\u044f \u0446\u0435\u043f\u0435\u0439 \u0422\u0422 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u043b\u0435\u043c\u043c\u044b \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438 \u0437\u0430\u043c\u044b\u043a\u0430\u044e\u0442\u0441\u044f \u043f\u0435\u0440\u0435\u0434 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c, \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u044f \u043e\u043f\u0430\u0441\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u043e\u0439 \u0446\u0435\u043f\u0438 \u0422\u0422, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u0442\u044c \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0442\u044b\u0441\u044f\u0447 \u0432\u043e\u043b\u044c\u0442.<\/p>\n<h3>Q2: \u041c\u043e\u0436\u043d\u043e \u043b\u0438 \u0441\u043c\u0435\u0448\u0438\u0432\u0430\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0432 \u043e\u0434\u043d\u043e\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u0449\u0438\u0442\u0435?<\/h3>\n<p>\u0425\u043e\u0442\u044f \u043c\u043e\u043d\u0442\u0430\u0436 \u043d\u0430 DIN-\u0440\u0435\u0439\u043a\u0443 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438 \u0432\u043e\u0437\u043c\u043e\u0436\u0435\u043d, \u044f \u043d\u0430\u0441\u0442\u043e\u044f\u0442\u0435\u043b\u044c\u043d\u043e \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u044e \u043d\u0435 \u0441\u043c\u0435\u0448\u0438\u0432\u0430\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439. \u0420\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0435 \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u0430 \u0442\u0435\u0440\u043c\u0438\u043d\u0430\u043b\u043e\u0432 \u0438\u043c\u0435\u044e\u0442 \u0440\u0430\u0437\u043d\u044b\u0435 \u0430\u043a\u0441\u0435\u0441\u0441\u0443\u0430\u0440\u044b, \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0438 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u043f\u0435\u0440\u0435\u043c\u044b\u0447\u0435\u043a. \u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0435\u0440\u0441\u043e\u043d\u0430\u043b \u0434\u043e\u043b\u0436\u0435\u043d \u0438\u043c\u0435\u0442\u044c \u043d\u0430 \u0441\u043a\u043b\u0430\u0434\u0435 \u043d\u0435\u0441\u043a\u043e\u043b\u044c\u043a\u043e \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0442\u0438\u043f\u043e\u0432. \u0412 \u0445\u043e\u0434\u0435 \u0430\u0443\u0434\u0438\u0442\u0430 \u043e\u0434\u043d\u043e\u0433\u043e \u043e\u0431\u044a\u0435\u043a\u0442\u0430 \u044f \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u043b \u0441\u0435\u043c\u044c \u0440\u0430\u0437\u043b\u0438\u0447\u043d\u044b\u0445 \u043c\u0430\u0440\u043e\u043a \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a \u0432 \u0434\u0432\u0435\u043d\u0430\u0434\u0446\u0430\u0442\u0438 \u0441\u0435\u043a\u0446\u0438\u044f\u0445 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u0447\u0442\u043e \u043f\u0440\u0438\u0432\u0435\u043b\u043e \u043a \u043a\u043e\u0448\u043c\u0430\u0440\u0443 \u0438\u043d\u0432\u0435\u043d\u0442\u0430\u0440\u0438\u0437\u0430\u0446\u0438\u0438 \u0438 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u0430\u043c \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439.<\/p>\n<h3>\u0412\u043e\u043f\u0440\u043e\u0441 3: \u041a\u0430\u043a \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u044c \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442 \u0437\u0430\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432?<\/h3>\n<p>\u041b\u0443\u0447\u0448\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0430 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0432\u0430\u0435\u0442 \u0437\u0430\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0432\u043e\u043b\u043e\u0447\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0434\u043e 40-50% \u043e\u0442 \u043f\u043b\u043e\u0449\u0430\u0434\u0438 \u043f\u043e\u043f\u0435\u0440\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0441 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0439 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u043e\u0439. \u042d\u0442\u043e \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u0432 \u0431\u0443\u0434\u0443\u0449\u0435\u043c \u0434\u043e\u0431\u0430\u0432\u043b\u044f\u0442\u044c \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0443 \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0430\u0435\u0442 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432 \u043f\u0440\u0438 \u043c\u043e\u043d\u0442\u0430\u0436\u0435. \u0414\u043b\u044f \u0441\u0438\u043b\u043e\u0432\u044b\u0445 \u0446\u0435\u043f\u0435\u0439, \u0432\u044b\u0434\u0435\u043b\u044f\u044e\u0449\u0438\u0445 \u0442\u0435\u043f\u043b\u043e, \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0443\u043c\u0435\u043d\u044c\u0448\u0438\u0442\u044c \u0437\u0430\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u0435 \u0434\u043e 30-35%. \u042f \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u044b\u0432\u0430\u044e \u0440\u0430\u0437\u043c\u0435\u0440 \u0432\u043e\u0437\u0434\u0443\u0445\u043e\u0432\u043e\u0434\u0430 \u043f\u0443\u0442\u0435\u043c \u0441\u0443\u043c\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043b\u043e\u0449\u0430\u0434\u0435\u0439 \u043f\u043e\u043f\u0435\u0440\u0435\u0447\u043d\u043e\u0433\u043e \u0441\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432 (\u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044e) \u0438 \u0434\u0435\u043b\u0435\u043d\u0438\u044f \u043d\u0430 0,4.<\/p>\n<h3>Q4: \u041a\u0430\u043a\u0438\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0438\u043c\u0435\u0442\u044c \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0431\u043b\u043e\u043a\u0438 \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445, \u043c\u043e\u043d\u0442\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u0432\u043d\u0435 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439?<\/h3>\n<p>\u0414\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u043c\u044b\u0445 \u0432\u043d\u0435 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439, \u0443\u043a\u0430\u0436\u0438\u0442\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0434\u043b\u044f \u0432\u0441\u0442\u0440\u0435\u0447\u0438:<br \/>\n- UL 1059 \u0441 \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u043e\u0439 \u0434\u043b\u044f \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u043d\u0435 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439<br \/>\n- \u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b IP20 (IP67 \u0434\u043b\u044f \u043e\u0442\u043a\u0440\u044b\u0442\u044b\u0445 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u0439)<br \/>\n- \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0430\u044f \u043e\u0436\u0438\u0434\u0430\u0435\u043c\u043e\u0439 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0435 \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b \u0438 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u043c\u0443 \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u0438\u044e<br \/>\n- \u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u044b\u0435 \u043a \u0443\u043b\u044c\u0442\u0440\u0430\u0444\u0438\u043e\u043b\u0435\u0442\u043e\u0432\u043e\u043c\u0443 \u0438\u0437\u043b\u0443\u0447\u0435\u043d\u0438\u044e, \u0435\u0441\u043b\u0438 \u043e\u043d\u0438 \u043f\u043e\u0434\u0432\u0435\u0440\u0433\u0430\u044e\u0442\u0441\u044f \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044e \u0441\u043e\u043b\u043d\u0435\u0447\u043d\u044b\u0445 \u043b\u0443\u0447\u0435\u0439<br \/>\n- \u0414\u043b\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0432 \u043f\u0440\u0438\u0431\u0440\u0435\u0436\u043d\u044b\u0445 \u0440\u0430\u0439\u043e\u043d\u0430\u0445 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0444\u0443\u0440\u043d\u0438\u0442\u0443\u0440\u0443 \u0438\u0437 \u043d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0435\u0439 \u0441\u0442\u0430\u043b\u0438 \u0438\u043b\u0438 \u0441\u043e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u043c \u043f\u043e\u043a\u0440\u044b\u0442\u0438\u0435\u043c<\/p>\n<h3>Q5: \u0414\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b \u043b\u0438 \u0432\u0441\u0442\u0430\u0432\u043d\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0434\u043b\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445, \u0438\u043b\u0438 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0443\u043a\u0430\u0437\u0430\u0442\u044c \u0442\u0438\u043f\u044b \u0441 \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u043c\u0438 \u0437\u0430\u0436\u0438\u043c\u0430\u043c\u0438?<\/h3>\n<p>\u0412\u0441\u0442\u0430\u0432\u043d\u044b\u0435 (\u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0435) \u043a\u043b\u0435\u043c\u043c\u044b \u043e\u0442 \u0438\u0437\u0432\u0435\u0441\u0442\u043d\u044b\u0445 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u0439 \u043f\u0440\u0438 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u043c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0438\u043b\u0438 \u043f\u0440\u0435\u0432\u043e\u0441\u0445\u043e\u0434\u044f\u0442 \u043f\u043e \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0441\u0442\u0438 \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u0435 \u0437\u0430\u0436\u0438\u043c\u044b. \u041a \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u043c \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0430\u043c \u043e\u0442\u043d\u043e\u0441\u044f\u0442\u0441\u044f \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0435 \u0443\u0441\u0438\u043b\u0438\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f, \u0443\u0441\u0442\u043e\u0439\u0447\u0438\u0432\u043e\u0441\u0442\u044c \u043a \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f\u043c \u0438 \u0431\u043e\u043b\u0435\u0435 \u0431\u044b\u0441\u0442\u0440\u044b\u0439 \u043c\u043e\u043d\u0442\u0430\u0436. \u0423\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u0430\u044f \u043c\u043e\u0434\u0435\u043b\u044c \u0437\u0430\u0436\u0438\u043c\u043d\u044b\u0445 \u043a\u043b\u0435\u043c\u043c \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u043d\u0430 \u043d\u0430 \u0432\u0430\u0448 \u0442\u0438\u043f \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u0430 (\u043e\u0434\u043d\u043e\u0436\u0438\u043b\u044c\u043d\u044b\u0439, \u043c\u043d\u043e\u0433\u043e\u0436\u0438\u043b\u044c\u043d\u044b\u0439 \u0438\u043b\u0438 \u0442\u043e\u043d\u043a\u043e\u0436\u0438\u043b\u044c\u043d\u044b\u0439 \u0441 \u043d\u0430\u043a\u043e\u043d\u0435\u0447\u043d\u0438\u043a\u043e\u043c), \u0438 \u0443\u0447\u0442\u0438\u0442\u0435, \u0447\u0442\u043e \u0434\u043b\u044f \u0431\u043e\u043b\u044c\u0448\u0438\u0445 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432 (\u0431\u043e\u043b\u0435\u0435 4 \u043c\u043c\u00b2) \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0432\u0438\u043d\u0442\u043e\u0432\u044b\u0435 \u0437\u0430\u0436\u0438\u043c\u044b.<\/p>\n<h3>Q6: \u041a\u0430\u043a \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043e\u0431\u0440\u0430\u0449\u0430\u0442\u044c\u0441\u044f \u0441 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u043c\u0438 \u043a\u043e\u043b\u043e\u0434\u043a\u0430\u043c\u0438 \u0434\u043b\u044f \u0446\u0435\u043f\u0435\u0439, \u043f\u0435\u0440\u0435\u0441\u0435\u043a\u0430\u044e\u0449\u0438\u0445 \u043e\u0442\u0441\u0435\u043a\u0438 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u0438 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f?<\/h3>\n<p>\u0426\u0435\u043f\u0438, \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u044f\u0449\u0438\u0435 \u043e\u0442 \u043e\u0434\u043d\u043e\u0433\u043e \u043e\u0442\u0441\u0435\u043a\u0430 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u043a \u0434\u0440\u0443\u0433\u043e\u043c\u0443, \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u043f\u0440\u0438\u0441\u0442\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u044f:<br \/>\n- \u0423\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0439\u0442\u0435 \u043a\u043b\u0435\u043c\u043c\u044b \u0442\u043e\u043b\u044c\u043a\u043e \u0432 \u043e\u0442\u0441\u0435\u043a\u0435 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<br \/>\n- \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043f\u0440\u043e\u0445\u043e\u0434\u043d\u044b\u0435 \u0432\u0442\u0443\u043b\u043a\u0438 \u0438\u043b\u0438 \u0431\u0430\u0440\u044c\u0435\u0440\u044b \u0441 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u043c<br \/>\n- \u041f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0440\u0430\u0437\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0444\u0430\u0437 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c\u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c\u0438<br \/>\n- \u0420\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043b\u0435\u043c\u043c \u0441 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f\u043c\u0438 \u0434\u043b\u044f \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0437\u0430\u0449\u0438\u0442\u044b<br \/>\n- \u0427\u0435\u0442\u043a\u043e \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0439\u0442\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u0445 \u044d\u0442\u0438\u043a\u0435\u0442\u043e\u043a<\/p>\n<h3>Q7: \u041a\u0430\u043a\u043e\u0439 \u0437\u0430\u043f\u0430\u0441 \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0435\u0439 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0442\u044c \u0434\u043b\u044f \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u043a\u043e\u043b\u043e\u0434\u043e\u043a?<\/h3>\n<p>\u041e\u0441\u043d\u043e\u0432\u044b\u0432\u0430\u044f\u0441\u044c \u043d\u0430 \u043c\u043e\u0435\u043c \u043e\u043f\u044b\u0442\u0435 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u044f \u043c\u043e\u0433\u0443 \u0438\u0445 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u0442\u044c:<br \/>\n- 5% \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u043a\u043b\u0435\u043c\u043c<br \/>\n- \u041f\u043e\u043b\u043d\u044b\u0439 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u043f\u0440\u0438\u043d\u0430\u0434\u043b\u0435\u0436\u043d\u043e\u0441\u0442\u0435\u0439 \u0434\u043b\u044f \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0438 \u044d\u0442\u0438\u043a\u0435\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0434\u043d\u043e\u0439 \u043f\u043e\u043b\u043d\u043e\u0439 \u0441\u0435\u043a\u0446\u0438\u0438<br \/>\n- \u041f\u0435\u0440\u0435\u043c\u044b\u0447\u043a\u0438 \u0438 \u043c\u043e\u0441\u0442\u044b \u0434\u043b\u044f \u043a\u0430\u0436\u0434\u043e\u0439 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u043e\u0439 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438<br \/>\n- \u0422\u043e\u0440\u0446\u0435\u0432\u044b\u0435 \u043a\u0440\u043e\u043d\u0448\u0442\u0435\u0439\u043d\u044b, \u043a\u0440\u044b\u0448\u043a\u0438 \u0438 \u043c\u043e\u043d\u0442\u0430\u0436\u043d\u044b\u0435 \u043f\u0440\u0438\u043d\u0430\u0434\u043b\u0435\u0436\u043d\u043e\u0441\u0442\u0438<br \/>\n- \u041c\u0438\u043d\u0438\u043c\u0443\u043c \u043f\u043e \u043e\u0434\u043d\u043e\u0439 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043a\u043b\u0435\u043c\u043c\u0435 (\u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c, \u0440\u0430\u0437\u044a\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c, \u0437\u0430\u0437\u0435\u043c\u043b\u0435\u043d\u0438\u0435)<\/p>\n<hr \/>\n<h2>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435: \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0432\u044b\u0432\u043e\u0434\u044b \u0434\u043b\u044f \u0443\u0441\u043f\u0435\u0448\u043d\u043e\u0433\u043e \u0432\u044b\u0431\u043e\u0440\u0430 \u043a\u043b\u0435\u043c\u043c\u043d\u043e\u0439 \u043a\u043e\u043b\u043e\u0434\u043a\u0438<\/h2>\n<p>\u0412\u044b\u0431\u043e\u0440 \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u044f \u0431\u0430\u043b\u0430\u043d\u0441\u0430 \u043c\u0435\u0436\u0434\u0443 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u043c\u0438 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u0438, \u044d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c\u044e, \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c\u044e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0438 \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c\u044e \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430. \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438, \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u0432 \u0434\u0430\u043d\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 - Phoenix Contact, Weidm\u00fcller, Wago, ABB Entrelec \u0438 \u0434\u0440\u0443\u0433\u0438\u0435 - \u0437\u0430\u0441\u043b\u0443\u0436\u0438\u043b\u0438 \u0441\u0432\u043e\u044e \u0440\u0435\u043f\u0443\u0442\u0430\u0446\u0438\u044e \u0431\u043b\u0430\u0433\u043e\u0434\u0430\u0440\u044f \u043d\u0435\u0438\u0437\u043c\u0435\u043d\u043d\u043e\u043c\u0443 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0443 \u0438 \u0432\u0441\u0435\u0441\u0442\u043e\u0440\u043e\u043d\u043d\u0435\u0439 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0435.<\/p>\n<p><strong>\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043e\u0442\u0431\u043e\u0440\u0430, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0437\u0430\u043f\u043e\u043c\u043d\u0438\u0442\u044c:<\/strong><\/p>\n<ol>\n<li><strong>\u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0438 \u0442\u043e\u043a\u0430<\/strong> \u043f\u0440\u0435\u0432\u044b\u0448\u0430\u044e\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u0430\u0448\u0435\u0433\u043e \u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043d\u0430 25-50% \u043c\u0438\u043d\u0438\u043c\u0443\u043c<\/li>\n<li><strong>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u044b\u0445 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0435\u0439<\/strong> \u043a \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u043c \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u043c \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u043a \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f\u043c \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b<\/li>\n<li><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u044d\u043a\u043e\u0441\u0438\u0441\u0442\u0435\u043c \u0441 \u043e\u0434\u043d\u0438\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c<\/strong> \u0434\u043b\u044f \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u0438 \u0438 \u0443\u043f\u0440\u043e\u0449\u0435\u043d\u0438\u044f \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f<\/li>\n<li><strong>\u0423\u043a\u0430\u0436\u0438\u0442\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b<\/strong> (UL, IEC, CSA) \u0434\u043b\u044f \u0432\u0430\u0448\u0435\u0439 \u0433\u0435\u043e\u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438 \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u043e\u0439 \u0441\u0440\u0435\u0434\u044b.<\/li>\n<li><strong>\u0423\u0447\u0438\u0442\u044b\u0432\u0430\u0439\u0442\u0435 \u043e\u0431\u0449\u0443\u044e \u0441\u0442\u043e\u0438\u043c\u043e\u0441\u0442\u044c \u0436\u0438\u0437\u043d\u0435\u043d\u043d\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430<\/strong> \u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u0435\u0440\u0432\u043e\u043d\u0430\u0447\u0430\u043b\u044c\u043d\u0430\u044f \u0437\u0430\u043a\u0443\u043f\u043e\u0447\u043d\u0430\u044f \u0446\u0435\u043d\u0430<\/li>\n<\/ol>\n<p>\u041a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u044b, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0432\u044b \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u0442\u0435 \u0441\u0435\u0433\u043e\u0434\u043d\u044f, \u0431\u0443\u0434\u0443\u0442 \u0441\u043b\u0443\u0436\u0438\u0442\u044c \u0432\u0430\u0448\u0435\u043c\u0443 \u043e\u0431\u044a\u0435\u043a\u0442\u0443 \u0434\u0435\u0441\u044f\u0442\u0438\u043b\u0435\u0442\u0438\u044f\u043c\u0438. \u0418\u043d\u0432\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u0432 \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0443\u044e \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044e \u0438 \u0441\u043a\u0440\u043e\u043c\u043d\u044b\u0439 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 \u0431\u044e\u0434\u0436\u0435\u0442 \u0432 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u044b \u043f\u0440\u0438\u043d\u043e\u0441\u0438\u0442 \u0434\u0438\u0432\u0438\u0434\u0435\u043d\u0434\u044b \u0437\u0430 \u0441\u0447\u0435\u0442 \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439 \u0440\u0430\u0431\u043e\u0442\u044b, \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044f \u043e\u0442\u043a\u0430\u0437\u043e\u0432. \u041f\u0440\u0438\u043c\u0435\u043d\u0438\u0442\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u0437\u0434\u0435\u0441\u044c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0435 \u0441\u043f\u0438\u0441\u043a\u0438 \u0438 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043a \u0441\u0432\u043e\u0435\u043c\u0443 \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u043c\u0443 \u043f\u0440\u043e\u0435\u043a\u0442\u0443 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430, \u0438 \u0432\u044b \u0441\u043e\u0437\u0434\u0430\u0434\u0438\u0442\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u0434\u043e\u0441\u0442\u043e\u0439\u043d\u044b\u0435 \u0441\u043b\u043e\u0436\u043d\u043e\u0433\u043e \u0437\u0430\u0449\u0438\u0442\u043d\u043e\u0433\u043e \u0438 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u043e\u043d\u0438 \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u044e\u0442.<\/p>\n<h2>\u0421\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u044b<\/h2>\n<ul>`r`n<\/p>\n<li><a href=\"https:\/\/xbrele.com\/ru\/control-wiring-emc-false-trip-prevention\/\">\u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u042d\u041c\u0421 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u0435 \u043b\u043e\u0436\u043d\u044b\u0445 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0439<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/control-cable-selection-mv-panels\/\">\u0412\u044b\u0431\u043e\u0440 \u043a\u0430\u0431\u0435\u043b\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043f\u0430\u043d\u0435\u043b\u0435\u0439 MV<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/\">\u0414\u0435\u0442\u0430\u043b\u0438 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u044b<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/switchgear-parts\/contact-box\/\">\u0414\u0435\u0442\u0430\u043b\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0439 \u043a\u043e\u0440\u043e\u0431\u043a\u0438 \u0438\u0437 \u044d\u043f\u043e\u043a\u0441\u0438\u0434\u043d\u043e\u0439 \u0441\u043c\u043e\u043b\u044b<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ru\/switchgear\/\">\u041e\u0441\u043d\u043e\u0432\u044b \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/a><\/li>\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/C37.2\/\" target=\"_blank\" rel=\"noopener\">IEEE C37.2 \u043d\u043e\u043c\u0435\u0440\u0430 \u0444\u0443\u043d\u043a\u0446\u0438\u0439 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0438 \u043e\u0431\u043e\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/a><\/li>\n<\/ul>\n<p><!-- seo-final-3691 --><\/p>","protected":false},"excerpt":{"rendered":"<p>\u0421\u0440\u0430\u0432\u043d\u0438\u0442\u0435 \u043c\u0430\u0440\u043a\u0438 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0445 \u0431\u043b\u043e\u043a\u043e\u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044b, \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u0434\u043b\u044f \u043d\u0430\u0434\u0435\u0436\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f MV.<\/p>","protected":false},"author":3,"featured_media":3686,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3691","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/3691","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=3691"}],"version-history":[{"count":15,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/3691\/revisions"}],"predecessor-version":[{"id":4115,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/3691\/revisions\/4115"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/3686"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=3691"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=3691"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=3691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}