{"id":4123,"date":"2026-07-31T11:51:15","date_gmt":"2026-07-31T11:51:15","guid":{"rendered":"https:\/\/xbrele.com\/?p=4123"},"modified":"2026-08-18T14:58:20","modified_gmt":"2026-08-18T14:58:20","slug":"iec-62271-100-clause-by-clause-compliance-checklist-for-12kv-vcb","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ru\/iec-62271-100-clause-by-clause-compliance-checklist-for-12kv-vcb\/","title":{"rendered":"\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB IEC 62271-100: \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043a\u0430\u0436\u0434\u043e\u043c\u0443 \u043f\u0443\u043d\u043a\u0442\u0443 \u0434\u043b\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 12 kV"},"content":{"rendered":"<h2>\u041a\u0440\u0430\u0442\u043a\u0438\u0439 \u0432\u044b\u0432\u043e\u0434<\/h2>\n<ul>\n<li>\u041f\u0435\u0440\u0435\u0434 \u0432\u044b\u0431\u043e\u0440\u043e\u043c \u0438\u043b\u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0435\u043c VCB \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u0435 \u0440\u0430\u0431\u043e\u0447\u0438\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f.<\/li>\n<li>\u041e\u043f\u0438\u0440\u0430\u0439\u0442\u0435\u0441\u044c \u043d\u0430 \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u043e\u0441\u043c\u043e\u0442\u0440\u0430 \u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0430 \u043d\u0435 \u043d\u0430 \u043d\u0435\u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d\u043d\u044b\u0435 \u043f\u0440\u0435\u0434\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u044f.<\/li>\n<li>\u0425\u0440\u0430\u043d\u0438\u0442\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u044b \u043e \u043f\u0440\u0438\u0451\u043c\u043a\u0435, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u0438 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u043c\u0435\u0441\u0442\u0435 \u0441 \u0435\u0433\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0435\u0439.<\/li>\n<\/ul>\n<p>\u0417\u0430\u043a\u0443\u043f\u043a\u0430 \u0438\u043b\u0438 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f (VCB) 12 kV \u0431\u0435\u0437 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043a\u0430\u0440\u0442\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f IEC 62271-100 \u0447\u0430\u0441\u0442\u043e \u043f\u0440\u0438\u0432\u043e\u0434\u0438\u0442 \u043a \u0434\u043e\u0440\u043e\u0433\u043e\u0441\u0442\u043e\u044f\u0449\u0438\u043c \u0437\u0430\u0434\u0435\u0440\u0436\u043a\u0430\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0430, \u043f\u0440\u043e\u0432\u0430\u043b\u0443 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u044e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u043e\u0439 \u043f\u0440\u0438\u0451\u043c\u043a\u0438. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043e\u0431\u044a\u0451\u043c\u0435\u043d, \u0441\u043e\u0434\u0435\u0440\u0436\u0438\u0442 \u043c\u043d\u043e\u0433\u043e\u0447\u0438\u0441\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u0435\u0440\u0435\u043a\u0440\u0451\u0441\u0442\u043d\u044b\u0435 \u0441\u0441\u044b\u043b\u043a\u0438, \u0430 \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u044f 2021 \u0433\u043e\u0434\u0430, \u043d\u044b\u043d\u0435 \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043a\u0430\u043a IEC 62271-100:2021+AMD1:2024, \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0443\u0442\u043e\u0447\u043d\u0435\u043d\u0438\u044f, \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u043d\u0435\u0442 \u0432 \u0441\u0442\u0430\u0440\u044b\u0445 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u0445 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u0447\u043d\u044f\u0445. \u0412 \u0441\u0442\u0430\u0442\u044c\u0435 \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430 \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u043e\u0432\u0430\u043d\u044b \u0432 \u043f\u0440\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441 \u0443\u043a\u0430\u0437\u0430\u043d\u0438\u0435\u043c \u043f\u0443\u043d\u043a\u0442\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u043c \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u044b \u043f\u043e \u0437\u0430\u043a\u0443\u043f\u043a\u0430\u043c, \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u044e\u0449\u0438\u0435 \u043f\u0440\u043e\u0435\u043a\u0442 \u0438 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u043d\u0430 \u0432\u0441\u0435\u0445 \u044d\u0442\u0430\u043f\u0430\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u0430.<\/p>\n<p>&gt; **\u0412\u0430\u0436\u043d\u043e\u0435 \u0443\u0432\u0435\u0434\u043e\u043c\u043b\u0435\u043d\u0438\u0435:** IEC 62271-100:2021 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u043c \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u043c. \u041f\u0440\u0438\u0432\u0435\u0434\u0451\u043d\u043d\u044b\u0435 \u0437\u0434\u0435\u0441\u044c \u0444\u043e\u0440\u043c\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0438 \u043f\u0443\u043d\u043a\u0442\u043e\u0432, \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0442\u0430\u0431\u043b\u0438\u0446 \u0438 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043e\u0431\u043e\u0437\u043d\u0430\u0447\u0435\u043d\u044b \u0441\u0441\u044b\u043b\u043a\u0430\u043c\u0438 \u043d\u0430 \u043e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u043d\u043e\u043c\u0435\u0440\u0430 \u043f\u0443\u043d\u043a\u0442\u043e\u0432. \u041f\u0440\u043e\u0435\u043a\u0442\u043d\u0430\u044f \u043a\u043e\u043c\u0430\u043d\u0434\u0430 \u0434\u043e\u043b\u0436\u043d\u0430 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0438\u043e\u0431\u0440\u0435\u0442\u0451\u043d\u043d\u043e\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0439 \u043a\u043e\u043f\u0438\u0435\u0439 IEC 62271-100:2021+AMD1:2024, \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u043d\u043e\u0439 \u0432 \u0438\u043d\u0442\u0435\u0440\u043d\u0435\u0442-\u043c\u0430\u0433\u0430\u0437\u0438\u043d\u0435 IEC \u0438\u043b\u0438 \u0443 \u0443\u043f\u043e\u043b\u043d\u043e\u043c\u043e\u0447\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0440\u0433\u0430\u043d\u0430 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0438\u0437\u0430\u0446\u0438\u0438. \u041d\u0435 \u043f\u043e\u043b\u0430\u0433\u0430\u0439\u0442\u0435\u0441\u044c \u043d\u0430 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u0444\u043e\u0440\u043c\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0438 \u0441\u043e \u0441\u0442\u0440\u0430\u043d\u0438\u0446 \u0442\u043e\u0432\u0430\u0440\u043e\u0432 \u0438\u043b\u0438 \u0438\u0437 \u0441\u0442\u043e\u0440\u043e\u043d\u043d\u0438\u0445 \u043e\u0431\u0437\u043e\u0440\u043e\u0432.<\/p>\n<p>\u2014<\/p>\n<h3>\u041e\u0431\u043b\u0430\u0441\u0442\u044c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0438 \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u0430\u044f \u0431\u0430\u0437\u0430: \u0447\u0442\u043e \u0438\u043c\u0435\u043d\u043d\u043e \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u0435\u0442 IEC 62271-100?<\/h3>\n<p>IEC 62271-100:2021 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u044f\u0435\u0442\u0441\u044f \u043d\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0434\u043b\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u0438\u043b\u0438 \u043d\u0430\u0440\u0443\u0436\u043d\u043e\u0439 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438, \u0440\u0430\u0431\u043e\u0442\u0430\u044e\u0449\u0438\u0435 \u043f\u0440\u0438 \u0447\u0430\u0441\u0442\u043e\u0442\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b 50 Hz \u0438\/\u0438\u043b\u0438 60 Hz \u0432 \u0441\u0435\u0442\u044f\u0445 \u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u0432\u044b\u0448\u0435 1 kV. VCB 12 kV \u043f\u043e\u043b\u043d\u043e\u0441\u0442\u044c\u044e \u0432\u0445\u043e\u0434\u0438\u0442 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u044c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043c\u0435\u0442\u043e\u0434\u044b \u043f\u0440\u044f\u043c\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435; \u0441\u0438\u043d\u0442\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u043c\u0435\u0442\u043e\u0434\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430\u043c\u0435\u0440\u0435\u043d\u043d\u043e \u0432\u044b\u0434\u0435\u043b\u0435\u043d\u044b \u0432 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442 IEC 62271-101, \u043d\u0430 \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043f\u0440\u044f\u043c\u043e \u0441\u0441\u044b\u043b\u0430\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u044d\u0442\u043e\u0439 \u0446\u0435\u043b\u0438. \u0414\u043b\u044f \u0432\u044b\u0431\u043e\u0440\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u0441\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u044c\u0442\u0435 \u0440\u0435\u0436\u0438\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0441 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker\/\">\u0410\u0441\u0441\u043e\u0440\u0442\u0438\u043c\u0435\u043d\u0442 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 XBRELE<\/a>.<\/p>\n<p>\u041d\u0430\u0440\u044f\u0434\u0443 \u0441 IEC 62271-100 \u043e\u0441\u043d\u043e\u0432\u043d\u043e\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442 IEC 62271-1:2017 \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u043e\u0431\u0449\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u043e \u0432\u0441\u0435\u043c\u0443 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u043c\u0443 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0434\u043b\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u0438\u043b\u0438 \u043d\u0430\u0440\u0443\u0436\u043d\u043e\u0439 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u043f\u0440\u0438 \u0440\u0430\u0431\u043e\u0447\u0438\u0445 \u0447\u0430\u0441\u0442\u043e\u0442\u0430\u0445 \u0434\u043e 60 Hz \u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u0432\u044b\u0448\u0435 1 kV, \u0435\u0441\u043b\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043d\u0435 \u043f\u0440\u0435\u0434\u0443\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u0435\u0442 \u0438\u043d\u043e\u0435. \u041d\u0430 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435 \u043c\u043d\u043e\u0433\u0438\u0435 \u043e\u0431\u0449\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u2014 \u0443\u0440\u043e\u0432\u043d\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438, \u043f\u0440\u0435\u0434\u0435\u043b\u044b \u043f\u0440\u0435\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b, \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439, \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0430 \u2014 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442\u0441\u044f IEC 62271-1 \u0438 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442\u0441\u044f \u0432 IEC 62271-100 \u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e\u043c \u0441\u0441\u044b\u043b\u043a\u0438. \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f, \u0438\u0433\u043d\u043e\u0440\u0438\u0440\u0443\u044e\u0449\u0438\u0439 IEC 62271-1, \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u043d\u043e \u043d\u0435\u043f\u043e\u043b\u043e\u043d.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/iec-62271-100-clause-by-clause-compliance-checklist-for-12kv-vcb-fig-01.webp\" alt=\"XBRELE IEC 62271-100 \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB 12 kV \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0430\u043c \u2014 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043d\u0430\u044f \u0441\u0445\u0435\u043c\u0430\" \/><\/figure><figcaption>\u0420\u0438\u0441\u0443\u043d\u043e\u043a 1 \u2014 \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 VCB \u0438 \u0438\u0437\u043e\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u043f\u043e\u043b\u044e\u0441\u0430; \u0434\u043b\u044f \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u043e\u0439 \u0438\u0435\u0440\u0430\u0440\u0445\u0438\u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0435 \u044d\u043a\u0437\u0435\u043c\u043f\u043b\u044f\u0440\u044b IEC \u0438 \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d\u043d\u044b\u0435 \u0447\u0435\u0440\u0442\u0435\u0436\u0438.<\/figcaption><p>\u041e\u0431\u043b\u0430\u0441\u0442\u044c \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0438\u0437\u0434\u0435\u043b\u0438\u044f 12 kV, \u0440\u0430\u0441\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0432 \u044d\u0442\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c\u0443 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e U_r 12 kV (\u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b 12 kV \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f\u043c IEC 60038); \u043e\u0431\u044b\u0447\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u044e\u0442\u0441\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0440\u0430\u0431\u043e\u0447\u0438\u0435 \u0442\u043e\u043a\u0438 630 A, 1 250 A \u0438\u043b\u0438 2 000 A \u0438 \u0442\u043e\u043a\u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f 25 kA \u0438\u043b\u0438 31.5 kA. \u0421\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0447\u043d\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u0430 \u043a \u043b\u044e\u0431\u044b\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f\u043c \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u0430 12 kV.<\/p>\n<p>\u2014<\/p>\n<h3>\u0421\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0447\u043d\u044f \u0441 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u043e\u0439 \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0430\u043c<\/h3>\n<p>\u041f\u0440\u0438\u0432\u0435\u0434\u0451\u043d\u043d\u044b\u0439 \u043d\u0438\u0436\u0435 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u043e\u0432\u0430\u043d \u043f\u043e \u043e\u0441\u043d\u043e\u0432\u043d\u044b\u043c \u0433\u0440\u0443\u043f\u043f\u0430\u043c \u043f\u0443\u043d\u043a\u0442\u043e\u0432 IEC 62271-100. \u0414\u043b\u044f \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u044d\u043b\u0435\u043c\u0435\u043d\u0442\u0430 \u0443\u043a\u0430\u0437\u0430\u043d\u044b \u0441\u0441\u044b\u043b\u043a\u0430 \u043d\u0430 \u043f\u0443\u043d\u043a\u0442, \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u043e \u043f\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044e, \u043e\u0436\u0438\u0434\u0430\u0435\u043c\u044b\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442-\u0434\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u043e \u0438 \u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0435\u043d\u043d\u0430\u044f \u0441\u0442\u043e\u0440\u043e\u043d\u0430. \u0418\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0441\u0442\u043e\u043b\u0431\u0435\u0446 \u00ab\u0421\u0442\u0430\u0442\u0443\u0441\u00bb (\u043d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e \/ \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0435\u0442\u0441\u044f \/ \u043f\u0440\u043e\u0439\u0434\u0435\u043d\u043e \/ \u043d\u0435 \u043f\u0440\u043e\u0439\u0434\u0435\u043d\u043e \/ \u043d\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e) \u043f\u0440\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445. \u041f\u0440\u0438 \u043f\u043b\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0438 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438 \u0432\u0435\u0434\u0435\u043d\u0438\u0438 \u0437\u0430\u043f\u0438\u0441\u0435\u0439 \u0441\u043e\u0433\u043b\u0430\u0441\u0443\u0439\u0442\u0435 \u0434\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u0441 <a href=\"https:\/\/xbrele.com\/ru\/vcb-fat-sat-acceptance-test-checklist\/\">\u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u043c \u043f\u0435\u0440\u0435\u0447\u043d\u0435\u043c \u043f\u0440\u0438\u0435\u043c\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 VCB<\/a>.<\/p>\n<p>#### \u041f\u0443\u043d\u043a\u0442 4 \u2014 \u041d\u043e\u0440\u043c\u0430\u043b\u044c\u043d\u044b\u0435 \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438<\/p>\n<table>\n<thead>\n<tr>\n<th>#<\/th>\n<th>\u041f\u0443\u043d\u043a\u0442<\/th>\n<th>\u041e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u043e<\/th>\n<th>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435<\/th>\n<th>\u041e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0435\u043d\u043d\u0430\u044f \u0441\u0442\u043e\u0440\u043e\u043d\u0430<\/th>\n<th>\u0421\u0442\u0430\u0442\u0443\u0441<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>4.01<\/td>\n<td>4.1<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b (\u22125 \u00b0C\u2026+40 \u00b0C \u0434\u043b\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u0433\u043e \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0433\u043e \u0438\u0441\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f; \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c)<\/td>\n<td>\u042d\u043a\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442, \u043e\u0442\u0447\u0451\u0442 \u043e\u0431\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0438<\/td>\n<td>\u0417\u0430\u043a\u0430\u0437\u0447\u0438\u043a<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>4.02<\/td>\n<td>4.2<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u0432\u044b\u0441\u043e\u0442\u0443 \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0438 \u2264 1 000 m \u043b\u0438\u0431\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u0442\u044c \u043f\u043e\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u044b\u0435 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u044b \u043f\u043e IEC 62271-1, \u0435\u0441\u043b\u0438 \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0430 \u0440\u0430\u0441\u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0430 \u0432\u044b\u0448\u0435<\/td>\n<td>\u0421\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u043e \u043e \u0432\u044b\u0441\u043e\u0442\u0435 \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0438<\/td>\n<td>\u0417\u0430\u043a\u0430\u0437\u0447\u0438\u043a<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>4.03<\/td>\n<td>4.3<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u044b\u0439 \u043a\u043b\u0430\u0441\u0441 \u0432\u043b\u0430\u0436\u043d\u043e\u0441\u0442\u0438 (\u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0435 \u0438\u0441\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u0435, \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0446\u0438\u0438, \u043d\u0430\u0440\u0443\u0436\u043d\u0430\u044f \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430)<\/td>\n<td>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430<\/td>\n<td>\u0417\u0430\u043a\u0430\u0437\u0447\u0438\u043a<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>4.04<\/td>\n<td>4.4<\/td>\n<td>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 (\u0441\u0435\u0439\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0437\u043e\u043d\u0430, \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0451\u043d\u043d\u0430\u044f \u0430\u0442\u043c\u043e\u0441\u0444\u0435\u0440\u0430, \u043d\u0435\u043e\u0431\u044b\u0447\u043d\u0430\u044f \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f) \u0438 \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043f\u0438\u0441\u044c\u043c\u0435\u043d\u043d\u043e\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u043e \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0438 \u044d\u0442\u0438\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439<\/td>\n<td>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442 \u043e\u0431 \u043e\u0442\u0441\u0442\u0443\u043f\u043b\u0435\u043d\u0438\u0438 \u0434\u043b\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439<\/td>\n<td>\u041e\u0431\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>#### \u041f\u0443\u043d\u043a\u0442 5 \u2014 \u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/p>\n<table>\n<thead>\n<tr>\n<th>#<\/th>\n<th>\u041f\u0443\u043d\u043a\u0442<\/th>\n<th>\u041e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u043e<\/th>\n<th>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435<\/th>\n<th>\u041e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0435\u043d\u043d\u0430\u044f \u0441\u0442\u043e\u0440\u043e\u043d\u0430<\/th>\n<th>\u0421\u0442\u0430\u0442\u0443\u0441<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>5.01<\/td>\n<td>5.1<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 U_r 12 kV \u043f\u043e \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0435 \u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u043d\u0430 \u0438\u0437\u0434\u0435\u043b\u0438\u0435<\/td>\n<td>\u0424\u043e\u0442\u043e\u0433\u0440\u0430\u0444\u0438\u044f \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.02<\/td>\n<td>5.2<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0443\u0440\u043e\u0432\u043d\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 (\u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u043e\u0435 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043c\u043e\u043b\u043d\u0438\u0438 75 kV peak; \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b 28 kV rms \u0434\u043b\u044f \u043a\u043b\u0430\u0441\u0441\u0430 12 kV) \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e IEC 62271-1, \u0442\u0430\u0431\u043b\u0438\u0446\u0435 1<\/td>\n<td>\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.03<\/td>\n<td>5.3<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0431\u043e\u0447\u0438\u0439 \u0442\u043e\u043a I_r; \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043f\u0440\u0435\u0434\u0435\u043b\u044b \u043f\u0440\u0435\u0432\u044b\u0448\u0435\u043d\u0438\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0442\u0438\u043f\u043e\u0432\u044b\u043c\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445, \u043f\u0443\u043d\u043a\u0442 6.5<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.04<\/td>\n<td>5.4<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f I_sc; \u0443\u043a\u0430\u0437\u0430\u0442\u044c \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442 \u043f\u0435\u0440\u0432\u043e\u0433\u043e \u043e\u0442\u043a\u043b\u044e\u0447\u0438\u0432\u0448\u0435\u0433\u043e\u0441\u044f \u043f\u043e\u043b\u044e\u0441\u0430 (\u043e\u0431\u044b\u0447\u043d\u043e 1.5 \u0434\u043b\u044f \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e \u0437\u0430\u0437\u0435\u043c\u043b\u0451\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b, 1.3 \u043f\u0440\u0438 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0438)<\/td>\n<td>\u0422\u0430\u0431\u043b\u0438\u0447\u043a\u0430 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.05<\/td>\n<td>5.5<\/td>\n<td>\u0423\u043a\u0430\u0437\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (\u043f\u0438\u043a\u043e\u0432\u043e\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435 = 2.5 \u00d7 I_sc)<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442, \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.06<\/td>\n<td>5.6<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0443\u044e \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u0430\u044f O\u20130.3 s\u2013CO\u20133 min\u2013CO; \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u2014 \u0435\u0441\u043b\u0438 \u0437\u0430\u0434\u0430\u043d\u0430)<\/td>\n<td>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442 \u0441\u0445\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041e\u0431\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.07<\/td>\n<td>5.7<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0439 \u0442\u043e\u043a (I_cw) \u0438 \u0434\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c (1 s \u0438\u043b\u0438 3 s)<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.08<\/td>\n<td>5.8<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043a\u043b\u0430\u0441\u0441\u044b \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0437\u0430\u0440\u044f\u0434\u043a\u0435 \u043a\u0430\u0431\u0435\u043b\u044f \u0438 \u043f\u0440\u0438 \u0437\u0430\u0440\u044f\u0434\u043a\u0435 \u043b\u0438\u043d\u0438\u0438<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442, \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043b\u0438\u043d\u0438\u0438 \u0438\u043b\u0438 \u043a\u0430\u0431\u0435\u043b\u044f<\/td>\n<td>\u041e\u0431\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.09<\/td>\n<td>5.9<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u0444\u0430\u0437\u043d\u043e\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 (\u0435\u0441\u043b\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e) \u043b\u0438\u0431\u043e \u043f\u0440\u044f\u043c\u043e \u0443\u043a\u0430\u0437\u0430\u0442\u044c, \u0447\u0442\u043e \u043e\u043d \u043d\u0435 \u043f\u0440\u0435\u0434\u0443\u0441\u043c\u043e\u0442\u0440\u0435\u043d<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442 \u0438\u043b\u0438 \u043f\u0438\u0441\u044c\u043c\u043e \u043e\u0431 \u043e\u0442\u0441\u0442\u0443\u043f\u043b\u0435\u043d\u0438\u0438<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.10<\/td>\n<td>5.10<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043a\u043b\u0430\u0441\u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 (M1 \u0438\u043b\u0438 M2)<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.11<\/td>\n<td>5.11<\/td>\n<td>\u0417\u0430\u044f\u0432\u0438\u0442\u044c \u043a\u043b\u0430\u0441\u0441 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 (E1, E2 \u0438\u043b\u0438 E3)<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>5.12<\/td>\n<td>5.12<\/td>\n<td>\u041f\u0440\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438 \u0437\u0430\u044f\u0432\u0438\u0442\u044c \u043a\u043b\u0430\u0441\u0441\u044b \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0438 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 (C1, C2; \u043a\u043b\u0430\u0441\u0441 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0437\u0430\u0436\u0438\u0433\u0430\u043d\u0438\u044f)<\/td>\n<td>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442 \u043f\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044e, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442<\/td>\n<td>\u041e\u0431\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/iec-62271-100-clause-by-clause-compliance-checklist-for-12kv-vcb-fig-02.webp\" alt=\"XBRELE IEC 62271-100 \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB 12 kV \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0430\u043c \u2014 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445\" \/><\/figure><figcaption>\u0420\u0438\u0441\u0443\u043d\u043e\u043a 2 \u2014 \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0439 VCB; \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0439\u0442\u0435 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u043f\u043e \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0435 \u0438 \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d\u043d\u044b\u043c \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u043c.<\/figcaption><p>#### \u041f\u0443\u043d\u043a\u0442 6 \u2014 \u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0438 \u0438\u0441\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044e<\/p>\n<table>\n<thead>\n<tr>\n<th>#<\/th>\n<th>\u041f\u0443\u043d\u043a\u0442<\/th>\n<th>\u041e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u043e<\/th>\n<th>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435<\/th>\n<th>\u041e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0435\u043d\u043d\u0430\u044f \u0441\u0442\u043e\u0440\u043e\u043d\u0430<\/th>\n<th>\u0421\u0442\u0430\u0442\u0443\u0441<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>6.01<\/td>\n<td>6.1<\/td>\n<td>\u0412\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0432\u0437\u0430\u0438\u043c\u043e\u0437\u0430\u043c\u0435\u043d\u044f\u0435\u043c\u043e\u0441\u0442\u0438 (\u0432\u044b\u043a\u0430\u0442\u043d\u044b\u0435 VCB \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u0432\u0437\u0430\u0438\u043c\u043e\u0437\u0430\u043c\u0435\u043d\u044f\u0435\u043c\u044b \u0432 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u043e\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435)<\/td>\n<td>\u0413\u0430\u0431\u0430\u0440\u0438\u0442\u043d\u044b\u0439 \u0447\u0435\u0440\u0442\u0451\u0436, \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0432\u0437\u0430\u0438\u043c\u043e\u0437\u0430\u043c\u0435\u043d\u044f\u0435\u043c\u043e\u0441\u0442\u0438<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>6.02<\/td>\n<td>6.2<\/td>\n<td>\u041f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438; \u0432 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u043f\u043e\u043b\u043e\u0436\u0435\u043d\u0438\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0435 \u0434\u043e\u043b\u0436\u043d\u043e \u043f\u043e\u0434\u0430\u0432\u0430\u0442\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043d\u0430 \u0433\u043b\u0430\u0432\u043d\u0443\u044e \u0446\u0435\u043f\u044c<\/td>\n<td>\u041b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u0445\u0435\u043c\u0430 \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043e\u043a, \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>6.03<\/td>\n<td>6.3<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b<\/td>\n<td>\u041f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439, \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442 \u0440\u0435\u043b\u0435<\/td>\n<td>\u041e\u0431\u0435 \u0441\u0442\u043e\u0440\u043e\u043d\u044b<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>6.04<\/td>\n<td>6.4<\/td>\n<td>\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u043e\u0433\u043e \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 \u0441 \u043d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u0438\u0435\u043c \u044d\u043d\u0435\u0440\u0433\u0438\u0438; \u043f\u0440\u0435\u0434\u0443\u0441\u043c\u043e\u0442\u0440\u0435\u0442\u044c \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u044c \u0440\u0443\u0447\u043d\u043e\u0433\u043e \u0432\u0437\u0432\u043e\u0434\u0430; \u0443\u043a\u0430\u0437\u0430\u0442\u044c \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u044b\u0445 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0439 (anti-pumping)<\/td>\n<td>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043f\u0430\u0441\u043f\u043e\u0440\u0442 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430, \u0441\u0445\u0435\u043c\u0430 \u0446\u0435\u043f\u0438 anti-pumping<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>6.05<\/td>\n<td>6.5<\/td>\n<td>\u0412\u0430\u043a\u0443\u0443\u043c\u043d\u0430\u044f \u043a\u0430\u043c\u0435\u0440\u0430: \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043c\u0435\u0436\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u043f\u0440\u043e\u043c\u0435\u0436\u0443\u0442\u043e\u043a; \u043f\u0440\u043e\u0432\u0435\u0441\u0442\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043e\u0431\u043e\u043b\u043e\u0447\u043a\u0438 \u043d\u0430 \u044d\u0442\u0430\u043f\u0435 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0437\u0430\u043f\u0438\u0441\u044c \u0440\u0435\u043d\u0442\u0433\u0435\u043d\u043e\u0432\u0441\u043a\u043e\u0433\u043e \u0438\u043b\u0438 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u0433\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>6.06<\/td>\n<td>6.6<\/td>\n<td>\u041f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043f\u0443\u0442\u0438 \u0443\u0442\u0435\u0447\u043a\u0438 \u0438 \u0432\u043e\u0437\u0434\u0443\u0448\u043d\u044b\u0435 \u0437\u0430\u0437\u043e\u0440\u044b \u043f\u043e IEC 62271-1, \u043f\u0443\u043d\u043a\u0442\u0443 6 \u0434\u043b\u044f \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u043e\u0439 \u0441\u0442\u0435\u043f\u0435\u043d\u0438 \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u0440\u0430\u0437\u043c\u0435\u0440\u043d\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>6.07<\/td>\n<td>6.7<\/td>\n<td>\u041f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0431\u043e\u043b\u043e\u0447\u043a\u0438 (\u043a\u043e\u0434 IP) \u043e\u0441\u043c\u043e\u0442\u0440\u043e\u043c; \u0434\u043b\u044f IP5X \u0438 \u0432\u044b\u0448\u0435 \u043f\u0440\u043e\u0432\u0435\u0441\u0442\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u043f\u044b\u043b\u0435\u0437\u0430\u0449\u0438\u0442\u0443<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f IP \u0438\u043b\u0438 \u0437\u0430\u043f\u0438\u0441\u044c \u043e\u0441\u043c\u043e\u0442\u0440\u0430<\/td>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>#### \u041f\u0443\u043d\u043a\u0442 7 \u2014 \u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f (\u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438)<\/p>\n<p>\u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u044f\u0442 \u043e\u0434\u0438\u043d \u0440\u0430\u0437 \u043d\u0430 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u043e\u0431\u0440\u0430\u0437\u0446\u0435, \u0447\u0442\u043e\u0431\u044b \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443. \u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u0434\u043e\u043b\u0436\u0435\u043d \u0431\u044b\u0442\u044c \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u043c, \u043f\u0440\u043e\u0441\u043b\u0435\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u043c \u0434\u043e \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 \u0438 \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u0443\u044e \u043a\u043e\u043c\u0431\u0438\u043d\u0430\u0446\u0438\u044e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u043c\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f.<\/p>\n<table>\n<thead>\n<tr>\n<th>#<\/th>\n<th>\u041f\u0443\u043d\u043a\u0442<\/th>\n<th>\u0422\u0435\u0441\u0442<\/th>\n<th>\u0421\u0432\u043e\u0434\u043a\u0430 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0435\u0432 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f<\/th>\n<th>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435<\/th>\n<th>\u0421\u0442\u0430\u0442\u0443\u0441<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>7.01<\/td>\n<td>6.2 (\u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c)<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b: 28 kV rms, 1 min, \u043d\u0430 \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u0445 \u0438 \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0437\u0435\u043c\u043b\u0438<\/td>\n<td>\u041d\u0435\u0442 \u043f\u0435\u0440\u0435\u043a\u0440\u044b\u0442\u0438\u0439 \u0438 \u043f\u0440\u043e\u0431\u0438\u0432\u043d\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.02<\/td>\n<td>6.2 (\u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c)<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u043e\u0435 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043c\u043e\u043b\u043d\u0438\u0438: 75 kV peak, 15 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 + 15 \u043e\u0442\u0440\u0438\u0446\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/td>\n<td>\u041d\u0435 \u0431\u043e\u043b\u0435\u0435 2 \u043f\u0440\u043e\u0431\u0438\u0432\u043d\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432 \u0432 15 \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u0430\u0445<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.03<\/td>\n<td>6.5<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u043d\u0430\u0433\u0440\u0435\u0432 \u043f\u0440\u0438 I_r (\u043d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u044b\u0439 \u0440\u0435\u0436\u0438\u043c)<\/td>\n<td>\u041f\u0440\u0435\u0432\u044b\u0448\u0435\u043d\u0438\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 IEC 62271-1, \u0442\u0430\u0431\u043b\u0438\u0446\u0430 3<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.04<\/td>\n<td>6.6<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u043a\u0440\u0430\u0442\u043a\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u044b\u0439 \u0442\u043e\u043a: I_cw \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438<\/td>\n<td>\u041f\u043e\u0432\u0440\u0435\u0436\u0434\u0435\u043d\u0438\u0439 \u043d\u0435\u0442; \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u043d\u0438\u0435 \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0437\u0430\u0434\u0430\u043d\u043d\u043e\u0433\u043e \u0432\u0440\u0435\u043c\u0435\u043d\u0438 \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u043e<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.05<\/td>\n<td>6.101<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (\u043f\u0440\u044f\u043c\u043e\u0439 \u043c\u0435\u0442\u043e\u0434): \u0440\u0435\u0436\u0438\u043c\u044b T10, T30, T60, T100, T100s \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0443 6.101<\/td>\n<td>\u041e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u043e; \u043e\u043f\u0430\u0441\u043d\u044b\u0445 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0439 \u043d\u0435\u0442<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.06<\/td>\n<td>6.103<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f<\/td>\n<td>\u0421\u0432\u0430\u0440\u0438\u0432\u0430\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043d\u0435\u0442; \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0438\u0441\u043f\u0440\u0430\u0432\u0435\u043d<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.07<\/td>\n<td>6.104<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 (\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c): M1 = 2 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439; M2 = 10 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439<\/td>\n<td>\u041e\u0442\u043a\u0430\u0437\u043e\u0432 \u0432 \u0440\u0430\u0431\u043e\u0442\u0435 \u0432 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u043e\u0432 \u043d\u0435\u0442<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e\u0431 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0438 \u043d\u0430 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.08<\/td>\n<td>6.105<\/td>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c: E1 = 100 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043f\u0440\u0438 \u043f\u043e\u043b\u043d\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0435 \u0438 I_r; E2 = 100; E3 = 200<\/td>\n<td>\u0418\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0432 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u0445 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445; \u043e\u0442\u043a\u0430\u0437\u0430 \u043a\u0430\u043c\u0435\u0440\u044b \u043d\u0435\u0442<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e\u0431 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0438 \u043d\u0430 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.09<\/td>\n<td>6.106<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043d\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u0438 \u0437\u0430\u0440\u044f\u0434\u043a\u0435 \u043a\u0430\u0431\u0435\u043b\u044f \u0438 \u043b\u0438\u043d\u0438\u0438 (\u0435\u0441\u043b\u0438 \u0437\u0430\u044f\u0432\u043b\u0435\u043d \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0439 \u043a\u043b\u0430\u0441\u0441)<\/td>\n<td>\u041f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0437\u0430\u0436\u0438\u0433\u0430\u043d\u0438\u044f \u043d\u0435\u0442 (C1) \u043b\u0438\u0431\u043e \u043e\u043d\u043e \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043e (C2)<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.10<\/td>\n<td>6.107<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0438 \u0431\u0430\u0442\u0430\u0440\u0435\u0439 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 (\u0435\u0441\u043b\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e)<\/td>\n<td>\u041a\u0440\u0438\u0442\u0435\u0440\u0438\u0439 \u043a\u043b\u0430\u0441\u0441\u0430 \u043f\u043e \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u043c\u0443 \u0437\u0430\u0436\u0438\u0433\u0430\u043d\u0438\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.11<\/td>\n<td>6.108<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0442\u0438\u0432\u043e\u0444\u0430\u0437\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 (\u0435\u0441\u043b\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e)<\/td>\n<td>\u041e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0431\u0435\u0437 \u043e\u043f\u0430\u0441\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>7.12<\/td>\n<td>6.2 (\u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043f\u043e\u0441\u043b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c)<\/td>\n<td>\u041f\u043e\u0432\u0442\u043e\u0440\u0438\u0442\u044c \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c<\/td>\n<td>\u0422\u0435 \u0436\u0435 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f, \u0447\u0442\u043e \u0434\u043b\u044f 7.01\u20137.02<\/td>\n<td>\u041e\u0442\u0447\u0451\u0442 \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>**\u0414\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043f\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u043c\u0443 \u043f\u0435\u0440\u0435\u0447\u043d\u044e \u0434\u043b\u044f \u043f\u0443\u043d\u043a\u0442\u0430 7:** \u0437\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u0435 \u0443\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c \u043e\u0442\u0447\u0451\u0442\u0430 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u043e \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445. \u041f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435, \u0447\u0442\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u044f \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u0430 \u043f\u043e ILAC-MRA, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0432 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u0435 \u0442\u043e\u0447\u043d\u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0442 \u0437\u0430\u043a\u0430\u0437\u0430\u043d\u043d\u043e\u0439 \u043c\u043e\u0434\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0438\u0437\u0434\u0435\u043b\u0438\u044f, \u0430 \u0434\u0430\u0442\u0430 \u0432\u044b\u0434\u0430\u0447\u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u0430 \u0438 \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u0430\u044f \u0437\u0430\u043c\u0435\u043d\u0430 \u0435\u0433\u043e \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0435\u0439 AMD1:2024 \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u044b \u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u043c \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u043e\u043c. \u041f\u0435\u0440\u0435\u0434 \u043f\u0440\u0438\u0451\u043c\u043a\u043e\u0439 \u0441\u0432\u0435\u0440\u044c\u0442\u0435 \u0440\u0435\u0436\u0438\u043c \u0438 \u0434\u0430\u043d\u043d\u044b\u0435 \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438 \u0441 <a href=\"https:\/\/xbrele.com\/ru\/vacuum-circuit-breaker-ratings\/\">\u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u0430\u043c \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439<\/a> \u043f\u0435\u0440\u0435\u0434 \u043f\u0440\u0438\u0451\u043c\u043a\u043e\u0439.<\/p>\n<p>#### \u041f\u0443\u043d\u043a\u0442 8 \u2014 \u041f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f (\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f)<\/p>\n<p>\u041f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0432\u043e\u0434\u044f\u0442 \u043d\u0430 \u043a\u0430\u0436\u0434\u043e\u043c VCB, \u0432\u044b\u043f\u0443\u0441\u043a\u0430\u0435\u043c\u043e\u043c \u0441 \u0437\u0430\u0432\u043e\u0434\u0430. \u041e\u043d\u0438 \u043d\u0435 \u0437\u0430\u043c\u0435\u043d\u044f\u044e\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f, \u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u044f\u044e\u0442 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u0438 \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0438\u0439\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430.<\/p>\n<table>\n<thead>\n<tr>\n<th>#<\/th>\n<th>\u041f\u0443\u043d\u043a\u0442<\/th>\n<th>\u0422\u0435\u0441\u0442<\/th>\n<th>\u0421\u0432\u043e\u0434\u043a\u0430 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0435\u0432 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f<\/th>\n<th>\u0414\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0435 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435<\/th>\n<th>\u0421\u0442\u0430\u0442\u0443\u0441<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>8.01<\/td>\n<td>8.1<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435\u043c \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u043d\u0430 \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u044b\u0445 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u0445 \u0438 \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0437\u0435\u043c\u043b\u0438 (\u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u044b\u0439 \u0438\u043b\u0438 \u043f\u043e\u043b\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u2014 \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f)<\/td>\n<td>\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0432\u0441\u043f\u044b\u0448\u043a\u0438<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>8.02<\/td>\n<td>8.2<\/td>\n<td>\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u0433\u043b\u0430\u0432\u043d\u043e\u0439 \u0446\u0435\u043f\u0438 (\u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432, \u00b5\u03a9) \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0440\u0430\u0431\u043e\u0447\u0435\u043c \u0442\u043e\u043a\u0435 \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u043f\u0443\u043d\u043a\u0442\u0443 6.4<\/td>\n<td>\u0412 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445 \u043e\u0431\u044a\u044f\u0432\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u0435\u043c \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f (\u043e\u0431\u044b\u0447\u043d\u043e \u2264 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f; \u0441\u0440\u0430\u0432\u043d\u0438\u0442\u044c \u0441 \u0438\u0441\u0445\u043e\u0434\u043d\u044b\u043c \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435\u043c \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439)<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>8.03<\/td>\n<td>8.3<\/td>\n<td>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u044b\u0445 \u043a\u0430\u043c\u0435\u0440 (\u0435\u0441\u043b\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0438\u043c\u043e, \u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u0430 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u044b\u043c \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435\u043c)<\/td>\n<td>\u041d\u0435\u0442 \u0430\u043d\u043e\u043c\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u0438\u0447\u043d\u044b\u0445 \u0440\u0430\u0437\u0440\u044f\u0434\u043e\u0432 \u0438\u043b\u0438 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u043e\u0431\u043e\u044f, \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0449\u0438\u0445 \u043d\u0430 \u043f\u043e\u0442\u0435\u0440\u044e \u0432\u0430\u043a\u0443\u0443\u043c\u0430<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>8.04<\/td>\n<td>8.4<\/td>\n<td>\u041c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f: \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c, \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u0438 \u043c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u043c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0438 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0446\u0435\u043f\u0435\u0439 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/td>\n<td>\u041f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0440\u0430\u0431\u043e\u0442\u0430 \u043f\u0440\u0438 \u0432\u0441\u0435\u0445 \u0443\u0440\u043e\u0432\u043d\u044f\u0445 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f; \u0432\u0440\u0435\u043c\u044f \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0432 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u0445<\/td>\n<td>\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<tr>\n<td>8.05<\/td>\n<td>8.5<\/td>\n<td>\u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0442\u0438\u0432\u043d\u044b\u0435 \u0438 \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438: \u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438, \u043f\u0440\u043e\u0432\u043e\u0434\u043a\u0438, \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0446\u0435\u043f\u0435\u0439 \u0438 \u043c\u0435\u0442\u043e\u043a \u043c\u043e\u043c\u0435\u043d\u0442\u0430 \u0437\u0430\u0442\u044f\u0436\u043a\u0438<\/td>\n<td>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0447\u0435\u0440\u0442\u0435\u0436\u0443; \u0432\u0438\u0434\u0438\u043c\u044b\u0445 \u0434\u0435\u0444\u0435\u043a\u0442\u043e\u0432 \u043d\u0435\u0442<\/td>\n<td>\u0417\u0430\u043f\u0438\u0441\u044c \u043e\u0441\u043c\u043e\u0442\u0440\u0430 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443<\/td>\n<td>\u041d\u0435 \u043d\u0430\u0447\u0430\u0442\u043e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>**\u0414\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043f\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u043c\u0443 \u043f\u0435\u0440\u0435\u0447\u043d\u044e \u0434\u043b\u044f \u043f\u0443\u043d\u043a\u0442\u0430 8:** \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u0435, \u0447\u0442\u043e \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u0435\u0440\u0435\u0434\u0430\u044e\u0442\u0441\u044f \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u043c\u0438 \u043e\u0442\u0447\u0451\u0442\u0430\u043c\u0438 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443, \u0430 \u043d\u0435 \u0441\u0432\u043e\u0434\u043a\u043e\u0439 \u043f\u043e \u043f\u0430\u0440\u0442\u0438\u0438; \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0435 \u043d\u043e\u043c\u0435\u0440\u0430 \u0432 \u043e\u0442\u0447\u0451\u0442\u0430\u0445 \u0434\u043e\u043b\u0436\u043d\u044b \u0441\u043e\u0432\u043f\u0430\u0434\u0430\u0442\u044c \u0441 \u0443\u043f\u0430\u043a\u043e\u0432\u043e\u0447\u043d\u044b\u043c \u043b\u0438\u0441\u0442\u043e\u043c. \u041f\u0440\u043e\u0430\u043d\u0430\u043b\u0438\u0437\u0438\u0440\u0443\u0439\u0442\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u043e \u043f\u0430\u0440\u0442\u0438\u0438, \u0447\u0442\u043e\u0431\u044b \u0432\u044b\u044f\u0432\u0438\u0442\u044c \u0432\u044b\u0431\u0440\u043e\u0441\u044b \u0434\u043e \u043e\u0442\u0433\u0440\u0443\u0437\u043a\u0438.<\/p>\n<p>\u2014<\/p>\n<h3>\u041a\u0430\u043a \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0442\u044c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u043d\u0430 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0435<\/h3>\n<p>\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u0435\u043d \u043a\u0430\u043a \u0447\u0430\u0441\u0442\u044c \u043e\u0444\u0438\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u043b\u0430\u043d\u0430 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 (QP) \u0438\u043b\u0438 \u043f\u043b\u0430\u043d\u0430 \u0438\u043d\u0441\u043f\u0435\u043a\u0446\u0438\u0439 \u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 (ITP), \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u043e\u043c \u0438 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u0435\u043c \u043f\u0440\u0438 \u0437\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u0434\u043e\u0433\u043e\u0432\u043e\u0440\u0430. \u0414\u043b\u044f \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u043f\u0443\u043d\u043a\u0442\u0430 \u043f\u0435\u0440\u0435\u0447\u043d\u044f \u043d\u0430\u0437\u043d\u0430\u0447\u044c\u0442\u0435 \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044f (W), \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u0443\u044e \u0442\u043e\u0447\u043a\u0443 \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 (H) \u0438\u043b\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 (R):<\/p>\n<ul>\n<li>**\u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u0430\u044f \u0442\u043e\u0447\u043a\u0430 \u043e\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 (H):** \u0440\u0430\u0431\u043e\u0442\u0443 \u043d\u0435\u043b\u044c\u0437\u044f \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0430\u0442\u044c \u043f\u043e\u0441\u043b\u0435 \u044d\u0442\u043e\u0433\u043e \u043f\u0443\u043d\u043a\u0442\u0430 \u0431\u0435\u0437 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u044f \u0443\u043f\u043e\u043b\u043d\u043e\u043c\u043e\u0447\u0435\u043d\u043d\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u0442\u0435\u043b\u044f \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0430, \u0435\u0433\u043e \u043f\u043e\u0434\u043f\u0438\u0441\u0438 \u0438 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f. \u041e\u0431\u044b\u0447\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u0442\u0441\u044f \u043a \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0432 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0435 \u0438 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 FAT.<\/li>\n<li>**\u0421\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u043a\u0430\u044f \u0442\u043e\u0447\u043a\u0430 (W):** \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a \u0434\u043e\u043b\u0436\u0435\u043d \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u043e\u0432\u0430\u0442\u044c, \u043d\u043e \u043f\u0440\u0438 \u0437\u0430\u0431\u043b\u0430\u0433\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u043c \u043f\u0438\u0441\u044c\u043c\u0435\u043d\u043d\u043e\u043c \u0443\u0432\u0435\u0434\u043e\u043c\u043b\u0435\u043d\u0438\u0438 \u043c\u043e\u0436\u0435\u0442 \u043e\u0442\u043a\u0430\u0437\u0430\u0442\u044c\u0441\u044f \u043e\u0442 \u0443\u0447\u0430\u0441\u0442\u0438\u044f. \u041e\u0431\u044b\u0447\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u0442\u0441\u044f \u043a \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f\u043c \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0435\u0434\u0438\u043d\u0438\u0446.<\/li>\n<li>**\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 (R):** \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442 \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0443 \u0432 \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u043d\u044b\u0439 \u0441\u0440\u043e\u043a; \u0444\u0438\u0437\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043f\u0440\u0438\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043d\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f. \u041e\u0431\u044b\u0447\u043d\u043e \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u0442\u0441\u044f \u043a \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0433\u0430\u0431\u0430\u0440\u0438\u0442\u043d\u043e\u0433\u043e \u0447\u0435\u0440\u0442\u0435\u0436\u0430.<\/li>\n<\/ul>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/iec-62271-100-clause-by-clause-compliance-checklist-for-12kv-vcb-fig-03.webp\" alt=\"XBRELE IEC 62271-100 \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB 12 kV \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0430\u043c \u2014 \u043a\u043e\u043d\u0442\u0435\u043a\u0441\u0442 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f\" \/><\/figure><figcaption>\u0420\u0438\u0441\u0443\u043d\u043e\u043a 3 \u2014 \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f VCB \u0432 \u044f\u0447\u0435\u0439\u043a\u0435; \u0434\u043b\u044f \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u044b \u0438\u043d\u0441\u043f\u0435\u043a\u0446\u0438\u0438 H, W \u0438 R \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0439\u0442\u0435 \u0443\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d\u043d\u044b\u0439 ITP.<\/figcaption><p>\u041f\u043e\u043f\u0440\u0430\u0432\u043a\u0430 AMD1:2024 \u043a \u0431\u0430\u0437\u043e\u0432\u043e\u043c\u0443 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 2021 \u0433\u043e\u0434\u0430 \u0432\u043d\u0435\u0441\u043b\u0430 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f. \u041f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0432 \u0438\u043d\u0442\u0435\u0440\u043d\u0435\u0442-\u043c\u0430\u0433\u0430\u0437\u0438\u043d\u0435 IEC <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"noopener\">IEC 62271-100:2021+AMD1:2024<\/a> \u0443\u043a\u0430\u0437\u0430\u043d \u043a\u0430\u043a \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0430\u044f \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u044f, \u043f\u0440\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u0443\u044e \u043a\u043e\u043f\u0438\u044e \u044d\u0442\u043e\u0433\u043e \u0441\u0432\u043e\u0434\u043d\u043e\u0433\u043e \u0438\u0437\u0434\u0430\u043d\u0438\u044f \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0430, \u0430 \u043d\u0435 \u043f\u043e\u043b\u0430\u0433\u0430\u0442\u044c\u0441\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u043d\u0430 \u0431\u0430\u0437\u043e\u0432\u044b\u0439 \u0442\u0435\u043a\u0441\u0442 2021 \u0433\u043e\u0434\u0430 \u0438\u043b\u0438 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435 \u043f\u0443\u043d\u043a\u0442\u043e\u0432 \u043f\u043e \u043e\u0431\u0449\u0435\u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b\u043c \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430\u043c \u0442\u043e\u0432\u0430\u0440\u043e\u0432. \u041f\u0440\u0438 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u043c \u0432\u044b\u043f\u0443\u0441\u043a\u0435 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0447\u043d\u044f \u0437\u0430\u0444\u0438\u043a\u0441\u0438\u0440\u0443\u0439\u0442\u0435 \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u044e IEC 62271-100, \u0434\u0435\u0439\u0441\u0442\u0432\u043e\u0432\u0430\u0432\u0448\u0443\u044e \u043d\u0430 \u0434\u0430\u0442\u0443 \u0437\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0433\u043e\u0432\u043e\u0440\u0430; \u043d\u0435 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u0438\u0442\u0435 \u043d\u0435\u0437\u0430\u043c\u0435\u0442\u043d\u043e \u043d\u0430 \u043d\u043e\u0432\u043e\u0435 \u0438\u0437\u0434\u0430\u043d\u0438\u0435 \u0432 \u0441\u0435\u0440\u0435\u0434\u0438\u043d\u0435 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0431\u0435\u0437 \u043e\u0444\u0438\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0439 \u043e\u0446\u0435\u043d\u043a\u0438 \u0432\u043b\u0438\u044f\u043d\u0438\u044f \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0439. \u041f\u0435\u0440\u0435\u0434 \u0432\u044b\u043f\u0443\u0441\u043a\u043e\u043c \u0437\u0430\u043f\u0440\u043e\u0441\u0430 \u0446\u0435\u043d \u0441\u0432\u0435\u0440\u044c\u0442\u0435 \u0442\u0440\u0435\u0431\u0443\u0435\u043c\u044b\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b \u0438 \u043e\u0442\u0447\u0451\u0442\u044b \u0441 <a href=\"https:\/\/xbrele.com\/ru\/iec-62271-100-type-test-vs-routine-test-vcb-rfq\/\">\u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e\u043c \u043f\u043e \u0434\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 IEC 62271-100<\/a> .<\/p>\n<p>\u2014<\/p>\n<h3>\u0420\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0451\u043d\u043d\u044b\u0435 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u043f\u0440\u0438 \u0430\u0443\u0434\u0438\u0442\u0430\u0445 VCB 12 kV<\/h3>\n<p>\u041f\u043e \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u0430\u043c \u0442\u0438\u043f\u0438\u0447\u043d\u044b\u0445 \u0430\u0443\u0434\u0438\u0442\u043e\u0432 (\u0431\u0435\u0437 \u043f\u0440\u0438\u0432\u044f\u0437\u043a\u0438 \u043a \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u043c \u043f\u0440\u043e\u0435\u043a\u0442\u0430\u043c \u043f\u043e\u0434 NDA) \u043f\u0440\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430\u0445 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f IEC 62271-100 \u0440\u0435\u0433\u0443\u043b\u044f\u0440\u043d\u043e \u0432\u044b\u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0438\u0435 \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f:<\/p>\n<p>1. **\u041d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u043e\u0432 \u0432 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u0435 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439:** \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0439 VCB \u0438\u043c\u0435\u0435\u0442 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f 31.5 kA, \u0442\u043e\u0433\u0434\u0430 \u043a\u0430\u043a \u0438\u043c\u0435\u044e\u0449\u0438\u0439\u0441\u044f \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u0435\u0442 25 kA. \u0418\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044c \u0437\u0430\u044f\u0432\u043b\u044f\u0435\u0442 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438, \u043a\u043e\u0442\u043e\u0440\u0443\u044e \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u043e\u0440\u0433\u0430\u043d \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0430 \u043d\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u043b \u0438 \u043d\u0435 \u043f\u0440\u0438\u043d\u044f\u043b.<\/p>\n<p>2. **\u041d\u0435\u043e\u0434\u043d\u043e\u0437\u043d\u0430\u0447\u043d\u043e\u0441\u0442\u044c \u043a\u043b\u0430\u0441\u0441\u0430 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438:** \u0432 \u0437\u0430\u043a\u0430\u0437\u0435 \u0443\u043a\u0430\u0437\u0430\u043d\u0430 \u00ab\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u044c M2\u00bb, \u043d\u043e \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0439 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u0435\u0442 \u0442\u043e\u043b\u044c\u043a\u043e M1. \u041d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u043e\u0431\u043d\u0430\u0440\u0443\u0436\u0438\u0432\u0430\u0435\u0442\u0441\u044f \u043f\u0440\u0438 FAT \u0438 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u043d\u043e\u0432\u044b\u0445 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043b\u0438\u0431\u043e \u043e\u0444\u0438\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043e\u0442\u0441\u0442\u0443\u043f\u043b\u0435\u043d\u0438\u044f \u043f\u043e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438.<\/p>\n<p>3. **\u0420\u0430\u0437\u0431\u0440\u043e\u0441 \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0432 \u043f\u0430\u0440\u0442\u0438\u0438:** \u043e\u0442\u0447\u0451\u0442\u044b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u043e\u0442 28 \u00b5\u03a9 \u0434\u043e 94 \u00b5\u03a9 \u0434\u043b\u044f \u043f\u0430\u0440\u0442\u0438\u0438 \u0432\u043d\u0435\u0448\u043d\u0435 \u043e\u0434\u0438\u043d\u0430\u043a\u043e\u0432\u044b\u0445 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043e\u0432. \u041d\u0430 \u0437\u0430\u0432\u043e\u0434\u0435 \u043d\u0435 \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u043b\u0441\u044f \u0430\u043d\u0430\u043b\u0438\u0437 \u0442\u0435\u043d\u0434\u0435\u043d\u0446\u0438\u0439, \u043d\u0435 \u0431\u044b\u043b\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u0439 \u0442\u043e\u0447\u043a\u0438, \u0447\u0442\u043e\u0431\u044b \u0432\u044b\u044f\u0432\u0438\u0442\u044c \u044d\u0442\u043e\u0442 \u0440\u0430\u0437\u0431\u0440\u043e\u0441.<\/p>\n<p>4. **\u041d\u0435\u044f\u0441\u043d\u043e\u0441\u0442\u044c \u0443\u0440\u043e\u0432\u043d\u044f \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439:** \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044c \u043f\u0440\u043e\u0432\u0451\u043b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u043e\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 \u043d\u0430 \u043f\u043e\u043d\u0438\u0436\u0435\u043d\u043d\u043e\u043c \u0443\u0440\u043e\u0432\u043d\u0435, \u043d\u0435 \u0443\u043a\u0430\u0437\u0430\u0432 \u044d\u0442\u0443 \u043f\u0440\u0430\u043a\u0442\u0438\u043a\u0443 \u0432 \u043f\u043b\u0430\u043d\u0435 \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u0434\u043e\u0433\u043e\u0432\u043e\u0440\u0430. \u0417\u0430\u043a\u0430\u0437\u0447\u0438\u043a \u043e\u0436\u0438\u0434\u0430\u043b \u043f\u043e\u043b\u043d\u044b\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439.<\/p>\n<p>5. **\u041e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438:** \u0432 \u043e\u0442\u0447\u0451\u0442\u0435 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 \u0443\u043a\u0430\u0437\u0430\u043d\u043e 2 000 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439, \u043e\u0434\u043d\u0430\u043a\u043e \u0432 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u043d\u0435\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u0443\u044e\u0449\u0435\u0433\u043e \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f, \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0433\u043e \u0434\u043b\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u043f\u043e\u0441\u043b\u0435 \u0438\u0437\u043d\u043e\u0441\u0430.<\/p>\n<p>6. **\u041d\u0435 \u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u044b \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f AMD1:2024:** \u043e\u0442\u0434\u0435\u043b \u0437\u0430\u043a\u0443\u043f\u043e\u043a \u043e\u0441\u043d\u043e\u0432\u044b\u0432\u0430\u043b \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u043d\u0430 IEC 62271-100:2021 \u0438 \u043d\u0435 \u043e\u0446\u0435\u043d\u0438\u043b \u043f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438 AMD1:2024 \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0433\u043e \u044d\u0442\u0430\u043f\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u0430.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/iec-62271-100-clause-by-clause-compliance-checklist-for-12kv-vcb-fig-04.webp\" alt=\"XBRELE IEC 62271-100 \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB 12 kV \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0430\u043c \u2014 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u043f\u0438\u0442\u0430\u043d\u0438\u044f\" \/><\/figure><figcaption>\u0420\u0438\u0441\u0443\u043d\u043e\u043a 4 \u2014 \u0438\u043b\u043b\u044e\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u043e\u0441\u043c\u043e\u0442\u0440\u0430 \u0438 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438. \u041e\u043d \u043d\u0435 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0434\u0438\u0430\u0433\u0440\u0430\u043c\u043c\u043e\u0439 \u041f\u0430\u0440\u0435\u0442\u043e, \u0432\u044b\u0431\u043e\u0440\u043a\u043e\u0439 \u043f\u043e \u043f\u0440\u043e\u0435\u043a\u0442\u0443 \u0438\u043b\u0438 \u0430\u043d\u0430\u043b\u0438\u0437\u043e\u043c \u0447\u0430\u0441\u0442\u043e\u0442\u044b.<\/figcaption><p>\u2014<\/p>\n<h3>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u043e \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 VCB \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEC 62271-100<\/h3>\n<h3>\u0427\u0435\u043c \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043e\u0442\u043b\u0438\u0447\u0430\u044e\u0442\u0441\u044f \u043e\u0442 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043f\u043e IEC 62271-100?<\/h3>\n<p>\u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f, \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u0435 \u0432 IEC 62271-100 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438 \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438, \u043f\u0440\u043e\u0432\u043e\u0434\u044f\u0442 \u043e\u0434\u0438\u043d \u0440\u0430\u0437 \u043d\u0430 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u043e\u0431\u0440\u0430\u0437\u0446\u0435 \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u043e\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438, \u0447\u0442\u043e\u0431\u044b \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0432\u0441\u0435\u043c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c, \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u043c \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0443 5. \u041e\u0431\u044b\u0447\u043d\u043e \u0438\u0445 \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0435\u0442 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044c \u0432 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 \u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438; \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u043d\u044b\u0439 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u044f\u0435\u0442\u0441\u044f \u043d\u0430 \u0432\u0441\u0435 \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0435 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u044b \u044d\u0442\u043e\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u043f\u0440\u0438 \u0443\u0441\u043b\u043e\u0432\u0438\u0438, \u0447\u0442\u043e \u043d\u0435 \u0432\u043d\u043e\u0441\u0438\u043b\u0438\u0441\u044c \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f, \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u044b\u0435 \u043e\u0431\u0435\u0441\u0446\u0435\u043d\u0438\u0442\u044c \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u044b \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439. \u041f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f, \u043d\u0430\u043f\u0440\u043e\u0442\u0438\u0432, \u043f\u0440\u043e\u0432\u043e\u0434\u044f\u0442 \u043d\u0430 \u043a\u0430\u0436\u0434\u043e\u0439 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u043e\u0439 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u043d\u043e\u0439 \u0435\u0434\u0438\u043d\u0438\u0446\u0435. \u0418\u0445 \u0446\u0435\u043b\u044c \u2014 \u043d\u0435 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044e, \u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c, \u0447\u0442\u043e \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u0435\u0442 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u0430 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438, \u043f\u0440\u043e\u0448\u0435\u0434\u0448\u0435\u0439 \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f. \u041f\u043e\u044d\u0442\u043e\u043c\u0443 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0443 8 \u2014 \u043f\u0440\u0435\u0436\u0434\u0435 \u0432\u0441\u0435\u0433\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0434\u0438\u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438, \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u0433\u043b\u0430\u0432\u043d\u043e\u0439 \u0446\u0435\u043f\u0438, \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0433\u0435\u0440\u043c\u0435\u0442\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u0432\u0430\u043a\u0443\u0443\u043c\u0430 \u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u2014 \u044f\u0432\u043b\u044f\u044e\u0442\u0441\u044f \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u044b\u043c \u0434\u043e\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u0435\u043c \u043a \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430\u043c \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0430 \u043d\u0435 \u0438\u0445 \u0437\u0430\u043c\u0435\u043d\u043e\u0439.<\/p>\n<h3>\u041f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u0442\u0441\u044f \u043b\u0438 IEC 62271-100 \u043a\u0430\u043a \u043a \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0438\u043c, \u0442\u0430\u043a \u0438 \u043a \u043d\u0430\u0440\u0443\u0436\u043d\u044b\u043c VCB 12 kV?<\/h3>\n<p>\u0414\u0430. IEC 62271-100:2021 \u043f\u0440\u044f\u043c\u043e \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u044f\u0435\u0442\u0441\u044f \u043d\u0430 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0434\u043b\u044f \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u0438 \u043d\u0430\u0440\u0443\u0436\u043d\u043e\u0439 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438. \u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f \u0434\u043b\u044f \u043d\u0430\u0440\u0443\u0436\u043d\u044b\u0445 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043e\u0432 \u0441\u0432\u044f\u0437\u0430\u043d\u044b \u0441 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 \u043a \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u043c \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 (\u043f\u0440\u0435\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u044b \u043e\u043a\u0440\u0443\u0436\u0430\u044e\u0449\u0435\u0439 \u0441\u0440\u0435\u0434\u044b, \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u0443\u043b\u044c\u0442\u0440\u0430\u0444\u0438\u043e\u043b\u0435\u0442\u0430, \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0433\u0440\u044f\u0437\u043d\u0435\u043d\u0438\u044f, \u0441\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b IP) \u0438 \u0441 \u043e\u0431\u0440\u0430\u0437\u0446\u0430\u043c\u0438, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u043c\u044b\u043c\u0438 \u0434\u043b\u044f \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0445 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439. \u0414\u043b\u044f \u043d\u0430\u0440\u0443\u0436\u043d\u043e\u0433\u043e VCB 12 kV \u0442\u0430\u043a\u0436\u0435 \u043c\u043e\u0433\u0443\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043e \u0441\u0435\u0439\u0441\u043c\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438, \u0435\u0441\u043b\u0438 \u044d\u0442\u043e\u0433\u043e \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0438. \u041e\u0431\u044b\u0447\u043d\u043e \u043e\u043d\u0438 \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u044e\u0442\u0441\u044f \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u043c\u0438 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u043c\u0438 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u043f\u0443\u043d\u043a\u0442\u0430 4 \u0438, \u043f\u0440\u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0441\u0442\u0438, \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c\u0438 IEC 62271-207 \u043a \u0441\u0435\u0439\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438. \u0423\u0442\u043e\u0447\u043d\u0438\u0442\u0435 \u0443 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f, \u0447\u0442\u043e \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0439 \u0432\u0430\u0440\u0438\u0430\u043d\u0442 \u0438\u0437\u0434\u0435\u043b\u0438\u044f \u043f\u0440\u043e\u0448\u0451\u043b \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0438\u043c\u0435\u043d\u043d\u043e \u0432 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 (\u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u0438\u043b\u0438 \u043d\u0430\u0440\u0443\u0436\u043d\u043e\u0439, \u0441 \u043e\u0431\u043e\u043b\u043e\u0447\u043a\u043e\u0439 \u0438\u043b\u0438 \u0431\u0435\u0437 \u043d\u0435\u0451), \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0439 \u0437\u0430\u043a\u0430\u0437\u0443.<\/p>\n<h3>\u041a\u0430\u043a \u0441\u0432\u044f\u0437\u0430\u043d\u044b IEC 62271-1 \u0438 IEC 62271-100 \u043f\u0440\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB 12 kV?<\/h3>\n<p>IEC 62271-1:2017 \u2014 \u043e\u0431\u0449\u0438\u0439 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u043a\u043e \u0432\u0441\u0435\u043c\u0443 \u0432\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430. \u041e\u043d \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u0432\u0441\u0435\u0433\u043e \u0441\u0435\u043c\u0435\u0439\u0441\u0442\u0432\u0430 \u0438\u0437\u0434\u0435\u043b\u0438\u0439, \u0435\u0441\u043b\u0438 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432\u044b\u0439 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, IEC 62271-100 \u0434\u043b\u044f \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439) \u043d\u0435 \u043f\u0440\u0435\u0434\u0443\u0441\u043c\u0430\u0442\u0440\u0438\u0432\u0430\u0435\u0442 \u0438\u043d\u043e\u0435. \u041f\u0440\u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0435 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f VCB 12 kV \u044d\u0442\u043e \u043e\u0437\u043d\u0430\u0447\u0430\u0435\u0442, \u0447\u0442\u043e \u0442\u0430\u0431\u043b\u0438\u0446\u044b \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0446\u0438\u0438 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438, \u043f\u0440\u0435\u0434\u0435\u043b\u044b \u043d\u0430\u0433\u0440\u0435\u0432\u0430 \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430 \u0432\u044b\u0432\u043e\u0434\u043e\u0432, \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0438\u043c \u0446\u0435\u043f\u044f\u043c, \u043c\u0430\u0440\u043a\u0438\u0440\u043e\u0432\u043a\u0430 \u0432\u044b\u0432\u043e\u0434\u043e\u0432 \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0441\u0442\u0435\u043f\u0435\u043d\u0438 \u0437\u0430\u0449\u0438\u0442\u044b IP \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u044b \u0432 IEC 62271-1 \u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u044b \u0432 IEC 62271-100 \u043f\u043e\u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e\u043c \u0441\u0441\u044b\u043b\u043a\u0438. \u041a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c, \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u0442\u043e\u043b\u044c\u043a\u043e IEC 62271-100 \u0431\u0435\u0437 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 IEC 62271-1, \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u043d\u043e \u043d\u0435\u043f\u043e\u043b\u043e\u043d. \u041d\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u0435 \u0434\u043e\u043b\u0436\u043d\u044b \u0438\u043c\u0435\u0442\u044c\u0441\u044f \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0435 \u043a\u043e\u043f\u0438\u0438 \u043e\u0431\u043e\u0438\u0445 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432, \u0438 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0438\u0437 \u043d\u0438\u0445 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c.<\/p>\n<h3>\u041c\u043e\u0436\u0435\u0442 \u043b\u0438 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u0438\u0435 \u043e\u0431 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u0437\u0430\u043c\u0435\u043d\u0438\u0442\u044c \u043f\u0440\u044f\u043c\u043e\u0435 \u0442\u0438\u043f\u043e\u0432\u043e\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 VCB 12 kV?<\/h3>\n<p>IEC 62271-100 \u0434\u043e\u043f\u0443\u0441\u043a\u0430\u0435\u0442 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u0438\u044f \u043e\u0431 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u0438, \u0438\u043d\u043e\u0433\u0434\u0430 \u043d\u0430\u0437\u044b\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435\u043c \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439 \u0438\u043b\u0438 \u044d\u043a\u0441\u0442\u0440\u0430\u043f\u043e\u043b\u044f\u0446\u0438\u0435\u0439 \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442\u043e\u0432 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u043f\u0440\u0438 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0451\u043d\u043d\u044b\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445. \u041f\u0440\u0438\u043d\u0446\u0438\u043f \u0441\u043e\u0441\u0442\u043e\u0438\u0442 \u0432 \u0442\u043e\u043c, \u0447\u0442\u043e \u0435\u0441\u043b\u0438 \u043d\u043e\u0432\u0430\u044f \u0438\u043b\u0438 \u0438\u0437\u043c\u0435\u043d\u0451\u043d\u043d\u0430\u044f \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u0434\u043e\u043a\u0430\u0437\u0443\u0435\u043c\u043e \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u0430 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438, \u0443\u0436\u0435 \u043f\u0440\u043e\u0448\u0435\u0434\u0448\u0435\u0439 \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f, \u043b\u0438\u0431\u043e \u043f\u0440\u0435\u0434\u044a\u044f\u0432\u043b\u044f\u0435\u0442 \u043a \u043d\u0435\u0439 \u043c\u0435\u043d\u044c\u0448\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f, \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0435 \u0434\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u0440\u0430\u0441\u043f\u0440\u043e\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u044b \u043d\u0430 \u043d\u043e\u0432\u0443\u044e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044e. \u041e\u0434\u043d\u0430\u043a\u043e \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u044c \u043d\u0435 \u043f\u0440\u0438\u043d\u0438\u043c\u0430\u0435\u0442\u0441\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438: \u0434\u043b\u044f \u043a\u0430\u0436\u0434\u043e\u0439 \u043a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u0431\u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u0435, \u043f\u0440\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u0435 \u043f\u043e \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u043c \u043f\u0440\u0430\u0432\u0438\u043b\u0430\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430. \u0414\u043b\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0435\u0439 \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u0438 \u043f\u0440\u0438 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u043c \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u0438 \u043f\u0440\u0430\u0432\u0438\u043b\u0430 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u043e\u0441\u043e\u0431\u0435\u043d\u043d\u043e \u0441\u0442\u0440\u043e\u0433\u0438, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u0433\u0435\u043e\u043c\u0435\u0442\u0440\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043a\u0430\u043c\u0435\u0440\u044b, \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u0443\u0433\u043e\u0439 \u043c\u043e\u0433\u0443\u0442 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u0432\u043b\u0438\u044f\u0442\u044c \u043d\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0443\u044e \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c, \u0434\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u0432\u043d\u0435\u0448\u043d\u0438\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u044b \u043d\u0435 \u0438\u0437\u043c\u0435\u043d\u0438\u043b\u0438\u0441\u044c. \u0417\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0443 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0437\u0430\u043f\u0440\u043e\u0441\u0438\u0442\u044c \u0443 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u043f\u043e\u043b\u043d\u043e\u0435 \u043e\u0431\u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u0438, \u0430 \u043d\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442 \u0441\u043e \u0441\u0441\u044b\u043b\u043a\u043e\u0439 \u043d\u0430 \u043f\u043e\u0445\u043e\u0436\u0443\u044e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044e, \u0438 \u0434\u043e \u043f\u0440\u0438\u043d\u044f\u0442\u0438\u044f \u043f\u0435\u0440\u0435\u0434\u0430\u0442\u044c \u044d\u0442\u043e \u043e\u0431\u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u043a\u043e\u043c\u043f\u0435\u0442\u0435\u043d\u0442\u043d\u043e\u043c\u0443 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u043e\u0440\u0433\u0430\u043d\u0443.<\/p>\n<h3>\u0427\u0442\u043e \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0443 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u0432 \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0438 AMD1:2024 \u043f\u0435\u0440\u0435\u0434 \u0432\u044b\u043f\u0443\u0441\u043a\u043e\u043c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0435\u0440\u0435\u0447\u043d\u044f \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f?<\/h3>\n<p>\u041f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 IEC 62271-100:2021+AMD1:2024 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0439 \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0435\u0439 \u0438 \u043f\u043e\u043f\u0440\u0430\u0432\u043a\u0438 \u043c\u043e\u0433\u0443\u0442 \u0432\u0432\u043e\u0434\u0438\u0442\u044c \u043f\u0435\u0440\u0435\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u043d\u044b\u0435 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u043d\u043e\u0432\u044b\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u0438\u043b\u0438 \u0438\u0437\u043c\u0435\u043d\u0451\u043d\u043d\u044b\u0435 \u043a\u0440\u0438\u0442\u0435\u0440\u0438\u0438 \u043f\u0440\u043e\u0445\u043e\u0436\u0434\u0435\u043d\u0438\u044f \u043f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 \u0431\u0430\u0437\u043e\u0432\u043e\u0439 \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0435\u0439 2021 \u0433\u043e\u0434\u0430, \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a \u0434\u043e\u043b\u0436\u0435\u043d \u043f\u0440\u043e\u0432\u0435\u0441\u0442\u0438 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u043e\u0446\u0435\u043d\u043a\u0443 \u0432\u043b\u0438\u044f\u043d\u0438\u044f. \u0414\u043b\u044f \u044d\u0442\u043e\u0433\u043e \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u043f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u0443\u044e \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u043a\u043e\u043f\u0438\u044e, \u0441\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u0438\u0442\u044c \u0441\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435 \u043f\u0443\u043d\u043a\u0442 \u0437\u0430 \u043f\u0443\u043d\u043a\u0442\u043e\u043c \u0441 \u0440\u0430\u043d\u0435\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0432\u0448\u0438\u043c\u0441\u044f \u043f\u0435\u0440\u0435\u0447\u043d\u0435\u043c \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u0442\u043e\u043b\u044c\u043a\u043e \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0438 2021 \u0433\u043e\u0434\u0430 \u0438 \u0432\u044b\u044f\u0432\u0438\u0442\u044c \u0432\u0441\u0435 \u043f\u043e\u0437\u0438\u0446\u0438\u0438, \u0432 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 AMD1:2024 \u0438\u0437\u043c\u0435\u043d\u044f\u0435\u0442 \u0434\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u0438\u043b\u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0443 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439. \u0418\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0432\u043d\u0435\u0441\u0442\u0438 \u0432 \u043e\u0444\u0438\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0435\u0435\u0441\u0442\u0440 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0439 \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0438 \u0437\u0430\u043a\u0440\u044b\u0442\u044c \u0434\u043e FAT, \u0430 \u0435\u0441\u043b\u0438 \u0437\u0430\u0442\u0440\u043e\u043d\u0443\u0442\u044b \u0434\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u2014 \u0434\u043e \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0437\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0433\u043e\u0432\u043e\u0440\u0430. \u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442-\u043c\u0430\u0433\u0430\u0437\u0438\u043d IEC \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 IEC 62271-100:2021+AMD1:2024 \u043a\u0430\u043a \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0443\u044e \u043a\u043e\u043d\u0441\u043e\u043b\u0438\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0443\u044e \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u044e; \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u0434\u043e\u043b\u0436\u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u044b\u0432\u0430\u0442\u044c\u0441\u044f \u043d\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0439 \u043a\u043e\u043f\u0438\u0438 \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0430, \u0430 \u043d\u0435 \u043d\u0430 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0438 \u0444\u043e\u0440\u043c\u0443\u043b\u0438\u0440\u043e\u0432\u043e\u043a \u043f\u0443\u043d\u043a\u0442\u043e\u0432 \u043f\u043e \u043f\u0443\u0431\u043b\u0438\u0447\u043d\u043e\u0439 \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0435 \u0442\u043e\u0432\u0430\u0440\u0430.<\/p>\n<h3>\u041a\u0430\u043a\u043e\u0432\u0430 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u0430\u044f \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 VCB 12 kV \u0438 \u043f\u043e\u0447\u0435\u043c\u0443 \u043e\u043d\u0430 \u0432\u0430\u0436\u043d\u0430?<\/h3>\n<p>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0447\u0435\u0440\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (O) \u0438 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f-\u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (CO), \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u0434\u043e\u043b\u0436\u0435\u043d \u0432\u044b\u043f\u043e\u043b\u043d\u044f\u0442\u044c \u0431\u0435\u0437 \u0440\u0435\u043c\u043e\u043d\u0442\u0430 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u044b \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u043e\u0432. \u0414\u043b\u044f \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u0433\u043e VCB IEC 62271-100 \u0437\u0430\u0434\u0430\u0451\u0442 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c O\u20130.3 s\u2013CO\u20133 min\u2013CO. \u041f\u0435\u0440\u0432\u0430\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f O \u043c\u043e\u0434\u0435\u043b\u0438\u0440\u0443\u0435\u0442 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u041a\u0417; \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b 0.3 \u0441\u0435\u043a\u0443\u043d\u0434\u044b \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0431\u0435\u0441\u0442\u043e\u043a\u043e\u0432\u043e\u0439 \u043f\u0430\u0443\u0437\u0435 \u043f\u0440\u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u043c \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438; \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f CO \u043c\u043e\u0434\u0435\u043b\u0438\u0440\u0443\u0435\u0442 \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0435 \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u043d\u0430 \u041a\u0417 \u0441 \u043d\u0435\u043c\u0435\u0434\u043b\u0435\u043d\u043d\u044b\u043c \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c; \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b 3 \u043c\u0438\u043d\u0443\u0442\u044b \u0434\u0430\u0451\u0442 \u043a\u0440\u0430\u0442\u043a\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u043d\u0430 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435; \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u044f\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f CO \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 \u0432\u0442\u043e\u0440\u043e\u0439 \u0446\u0438\u043a\u043b \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f. \u042d\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0432\u0430\u0436\u043d\u0430, \u043f\u043e\u0441\u043a\u043e\u043b\u044c\u043a\u0443 \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u0435\u0442 \u0442\u0435\u043f\u043b\u043e\u0432\u0443\u044e \u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u043d\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0443\u044e \u043a\u0430\u043c\u0435\u0440\u0443 \u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u043d\u0430\u043a\u043e\u043f\u043b\u0435\u043d\u0438\u044f \u044d\u043d\u0435\u0440\u0433\u0438\u0438. \u0415\u0441\u043b\u0438 \u043f\u0440\u043e\u0435\u043a\u0442 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0431\u043e\u043b\u0435\u0435 \u0431\u044b\u0441\u0442\u0440\u043e\u0433\u043e \u0446\u0438\u043a\u043b\u0430 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e\u0433\u043e \u0432\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0438\u043b\u0438 \u0431\u043e\u043b\u044c\u0448\u0435\u0433\u043e \u0447\u0438\u0441\u043b\u0430 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u041a\u0417 \u0437\u0430 \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u2014 \u0447\u0442\u043e \u0447\u0430\u0441\u0442\u043e \u0432\u0441\u0442\u0440\u0435\u0447\u0430\u0435\u0442\u0441\u044f \u0432 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0441\u0435\u0442\u044f\u0445, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u044b\u0445 \u0441 \u0441\u0435\u0442\u044f\u043c\u0438 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0438, \u2014 \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a \u0434\u043e\u043b\u0436\u0435\u043d \u0437\u0430\u0434\u0430\u0442\u044c \u044d\u0442\u043e \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u0438 \u0437\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0438 \u0434\u043e\u0433\u043e\u0432\u043e\u0440\u0430 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435 \u0440\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u043d\u043e\u0439 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u0438 \u0442\u0438\u043f\u043e\u0432\u044b\u043c\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438. \u041f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u0435 VCB \u0432 \u0440\u0435\u0436\u0438\u043c\u0435, \u0431\u043e\u043b\u0435\u0435 \u0442\u044f\u0436\u0451\u043b\u043e\u043c, \u0447\u0435\u043c \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u0430\u044f \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439, \u0431\u0435\u0437 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0449\u0438\u0445 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f \u043d\u0435\u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0435\u043c.<\/p>\n<h3>\u041a\u0430\u043a \u0438\u043d\u0442\u0435\u0440\u043f\u0440\u0435\u0442\u0438\u0440\u043e\u0432\u0430\u0442\u044c \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u043f\u0435\u0440\u0435\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u0440\u0438 \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0438\u0445 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445?<\/h3>\n<p>\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0433\u043b\u0430\u0432\u043d\u043e\u0439 \u0446\u0435\u043f\u0438 \u0438\u0437\u043c\u0435\u0440\u044f\u044e\u0442 \u043f\u0440\u0438 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u0445 \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0443 8 \u043d\u0438\u0437\u043a\u043e\u043e\u043c\u043d\u044b\u043c \u043e\u043c\u043c\u0435\u0442\u0440\u043e\u043c (\u043c\u0438\u043a\u0440\u043e\u043e\u043c\u043c\u0435\u0442\u0440\u043e\u043c) \u0441 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u044b\u043c \u0442\u043e\u043a\u043e\u043c, \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u044b\u043c \u0434\u043b\u044f \u043f\u0440\u0435\u043e\u0434\u043e\u043b\u0435\u043d\u0438\u044f \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u043d\u043e\u0439 \u043f\u043b\u0451\u043d\u043a\u0438, \u043e\u0431\u044b\u0447\u043d\u043e 100 A DC \u0438\u043b\u0438 \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f. \u0420\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442 \u0432 \u043c\u0438\u043a\u0440\u043e\u043e\u043c\u0430\u0445 (\u00b5\u03a9) \u043e\u0442\u0440\u0430\u0436\u0430\u0435\u0442 \u0441\u0443\u043c\u043c\u0430\u0440\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u043e\u0433\u043e \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043a\u0430\u043c\u0435\u0440\u044b, \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0439 \u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432 \u0432\u043d\u0443\u0442\u0440\u0438 \u043f\u043e\u043b\u044e\u0441\u043d\u043e\u0433\u043e \u0431\u043b\u043e\u043a\u0430 \u0438 \u0433\u043b\u0430\u0432\u043d\u044b\u0445 \u0432\u044b\u0432\u043e\u0434\u043e\u0432. \u041f\u0440\u0438 FAT \u0440\u0435\u0437\u0443\u043b\u044c\u0442\u0430\u0442 \u043a\u0430\u0436\u0434\u043e\u0439 \u0435\u0434\u0438\u043d\u0438\u0446\u044b \u0441\u0440\u0430\u0432\u043d\u0438\u0432\u0430\u044e\u0442 \u0441 \u0434\u0432\u0443\u043c\u044f \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u043c\u0438 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044f\u043c\u0438: \u043c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u0435\u0434\u0435\u043b\u043e\u043c \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f (\u0443\u043a\u0430\u0437\u0430\u043d\u043d\u044b\u043c \u0432 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u0435 \u0438 \u043e\u0442\u0447\u0451\u0442\u0435 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439) \u0438 \u0438\u0441\u0445\u043e\u0434\u043d\u044b\u043c \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435\u043c \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439. \u0414\u0430\u0436\u0435 \u0435\u0441\u043b\u0438 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u0430 \u0437\u043d\u0430\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e \u0432\u044b\u0448\u0435 \u0438\u0441\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u043d\u043e \u043d\u0438\u0436\u0435 \u043e\u0431\u044a\u044f\u0432\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u043c\u0430\u043a\u0441\u0438\u043c\u0443\u043c\u0430, \u0435\u0433\u043e \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043e\u0442\u043c\u0435\u0442\u0438\u0442\u044c \u0434\u043b\u044f \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f: \u043f\u043e\u0432\u044b\u0448\u0435\u043d\u043d\u043e\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0443\u043a\u0430\u0437\u044b\u0432\u0430\u0435\u0442 \u043d\u0430 \u0443\u0441\u0438\u043b\u0435\u043d\u043d\u044b\u0439 \u043d\u0430\u0433\u0440\u0435\u0432 \u043f\u0440\u0438 \u0442\u043e\u043a\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0435 \u0443\u0445\u0443\u0434\u0448\u0435\u043d\u0438\u0435 \u043f\u043e\u0432\u0435\u0440\u0445\u043d\u043e\u0441\u0442\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438\u043b\u0438 \u043d\u0435\u043e\u0434\u043d\u043e\u0440\u043e\u0434\u043d\u043e\u0441\u0442\u044c \u0441\u0431\u043e\u0440\u043a\u0438. \u0421\u043e\u043f\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u043e \u0432\u0441\u0435\u0439 \u043f\u0430\u0440\u0442\u0438\u0438, \u0430 \u043d\u0435 \u043e\u0446\u0435\u043d\u043a\u0430 \u043a\u0430\u0436\u0434\u043e\u0433\u043e \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u0430 \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u043e, \u2014 \u043d\u0430\u0438\u0431\u043e\u043b\u0435\u0435 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u044b\u0439 \u0441\u043f\u043e\u0441\u043e\u0431 \u0432\u044b\u044f\u0432\u0438\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u043d\u044b\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435\u043d\u043d\u044b\u0435 \u043f\u0440\u043e\u0431\u043b\u0435\u043c\u044b \u0434\u043e \u043e\u0442\u0433\u0440\u0443\u0437\u043a\u0438.<\/p>\n<h3>\u0412 \u0447\u0451\u043c \u043a\u043b\u044e\u0447\u0435\u0432\u044b\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u044f \u043a\u043b\u0430\u0441\u0441\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 E1, E2 \u0438 E3?<\/h3>\n<p>\u041a\u043b\u0430\u0441\u0441\u044b \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 \u043f\u043e\u043a\u0430\u0437\u044b\u0432\u0430\u044e\u0442 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 VCB \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0438\u043b\u0438 \u0431\u043b\u0438\u0437\u043a\u043e\u043c \u043a \u043d\u0435\u043c\u0443 \u0442\u043e\u043a\u0435 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438, \u043a\u043e\u0442\u043e\u0440\u043e\u0435 \u0430\u043f\u043f\u0430\u0440\u0430\u0442 \u043c\u043e\u0436\u0435\u0442 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u0431\u0435\u0437 \u0438\u0437\u043d\u043e\u0441\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043a\u0430\u043c\u0435\u0440\u044b \u0441\u0432\u0435\u0440\u0445 \u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u0435\u043b\u0430. \u0414\u043b\u044f E1 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f 100 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u043c \u0440\u0430\u0431\u043e\u0447\u0435\u043c \u0442\u043e\u043a\u0435 I_r; \u0434\u043b\u044f E2 \u2014 100 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439, \u043d\u043e \u043f\u0440\u0438 \u0431\u043e\u043b\u0435\u0435 \u0432\u044b\u0441\u043e\u043a\u043e\u043c \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u043c \u0442\u043e\u043a\u0435, \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c \u0431\u043e\u043b\u0435\u0435 \u0442\u044f\u0436\u0451\u043b\u043e\u043c\u0443 \u0440\u0435\u0436\u0438\u043c\u0443; \u0434\u043b\u044f E3 \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f 200 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439. \u041f\u043e\u0434\u0445\u043e\u0434\u044f\u0449\u0438\u0439 \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0430 \u043a\u043b\u0430\u0441\u0441 \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u043e\u0436\u0438\u0434\u0430\u0435\u043c\u043e\u0439 \u0447\u0430\u0441\u0442\u043e\u0442\u044b \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438. VCB, \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u043c\u044b\u0439 \u043f\u0440\u0435\u0438\u043c\u0443\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e \u0434\u043b\u044f \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u041a\u0417 \u043d\u0430 \u0440\u0430\u0434\u0438\u0430\u043b\u044c\u043d\u043e\u043c \u0444\u0438\u0434\u0435\u0440\u0435 \u0441 \u043d\u0435\u0431\u043e\u043b\u044c\u0448\u043e\u0439 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u043e\u0439, \u043c\u043e\u0436\u0435\u0442 \u0431\u044b\u0442\u044c \u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u0435\u043d \u043a\u043b\u0430\u0441\u0441\u0430 E1, \u0442\u043e\u0433\u0434\u0430 \u043a\u0430\u043a VCB \u0434\u043b\u044f \u0447\u0430\u0441\u0442\u044b\u0445 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0439 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f \u0438\u043b\u0438 \u0431\u0430\u0442\u0430\u0440\u0435\u0438 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442\u043e\u0440\u043e\u0432 \u0442\u0440\u0435\u0431\u0443\u0435\u0442 E2 \u0438\u043b\u0438 E3, \u0447\u0442\u043e\u0431\u044b \u0438\u0437\u043d\u043e\u0441 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043f\u0440\u0435\u0436\u0434\u0435\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u043e \u043d\u0435 \u0443\u0445\u0443\u0434\u0448\u0438\u043b \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 \u043c\u0435\u0436\u0434\u0443 \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u044b\u043c\u0438 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u0430\u043c\u0438. \u041d\u0430 \u044d\u0442\u0430\u043f\u0435 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0437\u0430\u043a\u0430\u0437\u0447\u0438\u043a\u0443 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u044c, \u0447\u0442\u043e \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u0439 \u0432 \u043f\u0430\u0441\u043f\u043e\u0440\u0442\u0435 \u043a\u043b\u0430\u0441\u0441 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438\u0437\u043d\u043e\u0441\u043e\u0441\u0442\u043e\u0439\u043a\u043e\u0441\u0442\u0438 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d \u0442\u0438\u043f\u043e\u0432\u044b\u043c\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438 \u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0444\u0430\u043a\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u043c\u0443 \u0440\u0435\u0436\u0438\u043c\u0443 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u0438 VCB.<\/p>\n<h3>\u041a\u0430\u043a\u0438\u0435 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u044b \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e \u0445\u0440\u0430\u043d\u0438\u0442\u044c \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 VCB 12 kV?<\/h3>\n<p>\u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438, \u043a\u043e\u0442\u043e\u0440\u044b\u0439 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0445\u0440\u0430\u043d\u0438\u0442\u044c \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u0432\u0441\u0435\u0433\u043e \u0441\u0440\u043e\u043a\u0430 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u2014 \u043e\u0431\u044b\u0447\u043d\u043e 25\u201340 \u043b\u0435\u0442 \u0434\u043b\u044f \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0441\u0440\u0435\u0434\u043d\u0435\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u2014 \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u043e\u0442\u0447\u0451\u0442\u044b \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 (\u0432 \u0442\u043e\u043c \u0447\u0438\u0441\u043b\u0435 \u043e\u0431\u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u044f \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u0438), \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u044b\u0435 \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u044b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0444\u043e\u0442\u043e\u0433\u0440\u0430\u0444\u0438\u0438 \u0442\u0430\u0431\u043b\u0438\u0447\u0435\u043a, \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0435 \u043f\u043e \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u044f\u043c \u0433\u0430\u0431\u0430\u0440\u0438\u0442\u043d\u044b\u0435 \u0438 \u0441\u0431\u043e\u0440\u043e\u0447\u043d\u044b\u0435 \u0447\u0435\u0440\u0442\u0435\u0436\u0438, \u043f\u043e\u0434\u043f\u0438\u0441\u0430\u043d\u043d\u044b\u0439 ITP \u0438\u043b\u0438 \u043f\u043b\u0430\u043d \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u0441 \u0437\u0430\u043f\u0438\u0441\u044f\u043c\u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0445 \u0442\u043e\u0447\u0435\u043a \u0438 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0432\u0435\u0440\u043e\u043a, \u0437\u0430\u043f\u0438\u0441\u044c \u043e \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0438 IEC 62271-100, \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043a\u0430\u043a \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u0430\u044f \u043e\u0441\u043d\u043e\u0432\u0430 \u043d\u0430 \u0434\u0430\u0442\u0443 \u0434\u043e\u0433\u043e\u0432\u043e\u0440\u0430, \u0430 \u0442\u0430\u043a\u0436\u0435 \u0433\u0440\u0430\u0444\u0438\u043a \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u0441 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u043c\u0438 \u0438\u0437\u043d\u043e\u0441\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u0430\u043c\u0438 \u043e\u0441\u043c\u043e\u0442\u0440\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043a\u0430\u043c\u0435\u0440\u044b. \u0414\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0432 \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043e\u0442\u0440\u0430\u0441\u043b\u044f\u0445 \u2014 \u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u043a\u0435, \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0439 \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u043a\u0435 \u0438 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u043e\u0439 \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0435 \u2014 \u044d\u0442\u043e \u0434\u043e\u0441\u044c\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0434\u043b\u044f \u043f\u043e\u0434\u0430\u0447\u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u043d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u044e\u0449\u0438\u043c \u043e\u0440\u0433\u0430\u043d\u0430\u043c \u0438\u043b\u0438 \u0430\u0443\u0434\u0438\u0442\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0430\u043a\u0442\u0438\u0432\u0430\u043c\u0438. \u041a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0441\u043b\u0435\u0434\u0443\u0435\u0442 \u0432\u0435\u0441\u0442\u0438 \u043f\u043e\u0434 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u0432\u0435\u0440\u0441\u0438\u0439 \u0438 \u0445\u0440\u0430\u043d\u0438\u0442\u044c \u0442\u0430\u043a, \u0447\u0442\u043e\u0431\u044b \u043e\u043d \u043e\u0441\u0442\u0430\u0432\u0430\u043b\u0441\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b\u043c \u043d\u0430 \u043f\u0440\u043e\u0442\u044f\u0436\u0435\u043d\u0438\u0438 \u0432\u0441\u0435\u0433\u043e \u0441\u0440\u043e\u043a\u0430 \u0441\u043b\u0443\u0436\u0431\u044b \u0430\u043a\u0442\u0438\u0432\u0430, \u0432 \u0442\u043e\u043c \u0447\u0438\u0441\u043b\u0435 \u043f\u043e\u0441\u043b\u0435 \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0438\u0437\u043c\u0435\u043d\u0435\u043d\u0438\u0439 \u0438\u043b\u0438 \u043f\u0435\u0440\u0435\u043d\u043e\u0441\u0430 \u0441\u0438\u0441\u0442\u0435\u043c, \u0438\u0437-\u0437\u0430 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u044b \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u0443\u0442\u0440\u0430\u0447\u0435\u043d\u044b.<\/p>\n<p>\u2014<\/p>\n<h3>\u0412\u0435\u0434\u0435\u043d\u0438\u0435 \u0437\u0430\u043f\u0438\u0441\u0435\u0439 \u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u0434\u043b\u044f \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f IEC 62271-100<\/h3>\n<p>\u0417\u0430\u043f\u043e\u043b\u043d\u0435\u043d\u043d\u044b\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0439 \u043f\u0435\u0440\u0435\u0447\u0435\u043d\u044c \u0431\u0435\u0441\u043f\u043e\u043b\u0435\u0437\u0435\u043d \u0431\u0435\u0437 \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0449\u0438\u0445 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432. \u041c\u0438\u043d\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442, \u0441\u043e\u043f\u0440\u043e\u0432\u043e\u0436\u0434\u0430\u044e\u0449\u0438\u0439 \u043f\u043e\u0441\u0442\u0430\u0432\u043a\u0443 VCB 12 kV \u043f\u043e IEC 62271-100, \u0432\u043a\u043b\u044e\u0447\u0430\u0435\u0442:<\/p>\n<ul>\n<li>**\u041e\u0442\u0447\u0451\u0442(\u044b) \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439:** \u043f\u043e\u043b\u043d\u044b\u0439 \u043e\u0442\u0447\u0451\u0442 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 ILAC-MRA, \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u044e\u0449\u0438\u0439 \u0432\u0441\u0435 \u043e\u0431\u044f\u0437\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0442\u0438\u043f\u043e\u0432\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f. \u041f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u0438\u0439 \u043e\u0431 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u043e\u0441\u0442\u0438 \u043e\u0431\u043e\u0441\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u043e\u043b\u0436\u043d\u043e \u0432\u0445\u043e\u0434\u0438\u0442\u044c \u0432 \u044d\u0442\u043e\u0442 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442.<\/li>\n<li>**\u041f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u044b \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439:** \u043e\u0442\u0434\u0435\u043b\u044c\u043d\u044b\u0435 \u043e\u0442\u0447\u0451\u0442\u044b \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443 \u0441 \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u043c\u0438 \u043d\u043e\u043c\u0435\u0440\u0430\u043c\u0438, \u043e\u0445\u0432\u0430\u0442\u044b\u0432\u0430\u044e\u0449\u0438\u0435 \u0432\u0441\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u043f\u043e \u043f\u0443\u043d\u043a\u0442\u0443 8. \u041e\u0442\u0447\u0451\u0442\u044b \u0434\u043e\u043b\u0436\u043d\u044b \u0431\u044b\u0442\u044c \u043f\u043e\u0434\u043f\u0438\u0441\u0430\u043d\u044b \u043a\u0432\u0430\u043b\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u043c \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043e\u043c-\u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u0435\u043c \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f.<\/li>\n<li>**\u0424\u043e\u0442\u043e\u0433\u0440\u0430\u0444\u0438\u044f(\u0438) \u0442\u0430\u0431\u043b\u0438\u0447\u043a\u0438:** \u043f\u043e \u043e\u0434\u043d\u043e\u0439 \u043d\u0430 \u043a\u0430\u0436\u0434\u0443\u044e \u0435\u0434\u0438\u043d\u0438\u0446\u0443, \u0441 \u0447\u0451\u0442\u043a\u0438\u043c \u043e\u0442\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u0438\u0435\u043c \u0432\u0441\u0435\u0445 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0439.<\/li>\n<li>**\u0413\u0430\u0431\u0430\u0440\u0438\u0442\u043d\u044b\u0435 \u0438 \u0441\u0431\u043e\u0440\u043e\u0447\u043d\u044b\u0435 \u0447\u0435\u0440\u0442\u0435\u0436\u0438:** \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0439, \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0430\u044e\u0449\u0438\u0435 \u043f\u0443\u0442\u0438 \u0443\u0442\u0435\u0447\u043a\u0438, \u0437\u0430\u0437\u043e\u0440\u044b \u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u044b \u0432\u0437\u0430\u0438\u043c\u043e\u0437\u0430\u043c\u0435\u043d\u044f\u0435\u043c\u043e\u0441\u0442\u0438.<\/li>\n<li>**ITP \u0438\u043b\u0438 \u043f\u043b\u0430\u043d \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u0441 \u043f\u043e\u0434\u043f\u0438\u0441\u0430\u043d\u043d\u044b\u043c\u0438 \u0437\u0430\u043f\u0438\u0441\u044f\u043c\u0438 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u044b\u0445 \u0438 \u0441\u0432\u0438\u0434\u0435\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0445 \u0442\u043e\u0447\u0435\u043a:** \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u0435 \u0432\u044b\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u044f \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0440\u0435\u0436\u0438\u043c\u0430 \u0438\u043d\u0441\u043f\u0435\u043a\u0446\u0438\u0439.<\/li>\n<li>**\u0421\u0441\u044b\u043b\u043a\u0430 \u043d\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0439 \u044d\u043a\u0437\u0435\u043c\u043f\u043b\u044f\u0440:** \u0437\u0430\u043f\u0438\u0441\u044c \u043e \u0440\u0435\u0434\u0430\u043a\u0446\u0438\u0438 IEC 62271-100 (IEC 62271-100:2021+AMD1:2024), \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u043d\u043e\u0439 \u0432 \u043f\u0440\u043e\u0435\u043a\u0442\u0435 \u043a\u0430\u043a \u043e\u0441\u043d\u043e\u0432\u0430 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f.<\/li>\n<li>**\u0414\u0430\u043d\u043d\u044b\u0435 \u043f\u043e \u0437\u0430\u043f\u0430\u0441\u043d\u044b\u043c \u0447\u0430\u0441\u0442\u044f\u043c \u0438 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e:** \u0433\u0440\u0430\u0444\u0438\u043a \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0438\u0437\u0433\u043e\u0442\u043e\u0432\u0438\u0442\u0435\u043b\u044f \u0441 \u043f\u0440\u0435\u0434\u0435\u043b\u0430\u043c\u0438 \u0438\u0437\u043d\u043e\u0441\u0430 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u043c\u044b\u043c\u0438 \u0438\u043d\u0442\u0435\u0440\u0432\u0430\u043b\u0430\u043c\u0438 \u043e\u0441\u043c\u043e\u0442\u0440\u0430 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u043e\u0439 \u043a\u0430\u043c\u0435\u0440\u044b.<\/li>\n<\/ul>\n<p>\u041e\u0440\u0433\u0430\u043d\u0438\u0437\u0443\u0439\u0442\u0435 \u044d\u0442\u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u044b \u0432 \u043f\u0440\u043e\u0435\u043a\u0442\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0434\u043e\u0441\u044c\u0435 \u0441 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u043c \u0432\u0435\u0440\u0441\u0438\u0439. \u0414\u043b\u044f \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043e\u0442\u0440\u0430\u0441\u043b\u0435\u0439 (\u044d\u043b\u0435\u043a\u0442\u0440\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u0435, \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u043a\u0430, \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u0430\u044f \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430) \u0434\u043e\u0441\u044c\u0435 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0442\u0440\u0435\u0431\u043e\u0432\u0430\u0442\u044c\u0441\u044f \u0442\u0430\u043a\u0436\u0435 \u0434\u043b\u044f \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0439 \u043f\u043e\u0434\u0430\u0447\u0438 \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u043d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u043c \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u0443\u044e\u0449\u0438\u043c \u043e\u0440\u0433\u0430\u043d\u0430\u043c. \u0425\u0440\u0430\u043d\u0438\u0442\u0435 \u0434\u043e\u0441\u044c\u0435 \u0432\u0435\u0441\u044c \u0441\u0440\u043e\u043a \u0441\u043b\u0443\u0436\u0431\u044b \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u2014 \u0437\u0430\u0447\u0430\u0441\u0442\u0443\u044e 25\u201340 \u043b\u0435\u0442 \u2014 \u0441\u043e\u0433\u043b\u0430\u0441\u043d\u043e \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f\u043c \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0430\u043a\u0442\u0438\u0432\u0430\u043c\u0438.<\/p>\n<p>\u2014<\/p>\n<h3>\u0418\u0442\u043e\u0433\u043e\u0432\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f \u043f\u0435\u0440\u0435\u0434 \u043f\u043e\u0434\u0430\u0447\u0435\u0439 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/h3>\n<p>\u041f\u0435\u0440\u0435\u0434 \u0432\u0432\u043e\u0434\u043e\u043c VCB 12 kV \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044e \u043f\u0440\u043e\u0432\u0435\u0434\u0438\u0442\u0435 \u0438\u0442\u043e\u0433\u043e\u0432\u0443\u044e \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f, \u0441\u0432\u044f\u0437\u044b\u0432\u0430\u044e\u0449\u0443\u044e \u0437\u0430\u0432\u043e\u0434\u0441\u043a\u0443\u044e \u043f\u0440\u0438\u0451\u043c\u043e\u0447\u043d\u0443\u044e \u0434\u043e\u043a\u0443\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u044e \u0441 \u043f\u0440\u0438\u0451\u043c\u043e-\u0441\u0434\u0430\u0442\u043e\u0447\u043d\u044b\u043c\u0438 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f\u043c\u0438 \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435 (SAT). \u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0434\u0438\u0442\u0435, \u0447\u0442\u043e \u043f\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0439 \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442 \u0430\u043f\u043f\u0430\u0440\u0430\u0442 \u0438\u043c\u0435\u0435\u0442 \u0442\u043e\u0442 \u0436\u0435 \u0441\u0435\u0440\u0438\u0439\u043d\u044b\u0439 \u043d\u043e\u043c\u0435\u0440, \u0447\u0442\u043e \u0443\u043a\u0430\u0437\u0430\u043d \u0432 \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u0435 FAT; \u0447\u0442\u043e \u043f\u0440\u0438 \u0442\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u0438\u0440\u043e\u0432\u043a\u0435 \u043e\u043d \u043d\u0435 \u043f\u043e\u0432\u0440\u0435\u0436\u0434\u0451\u043d (\u0435\u0441\u043b\u0438 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u043e, \u0432\u0438\u0437\u0443\u0430\u043b\u044c\u043d\u043e \u043e\u0441\u043c\u043e\u0442\u0440\u0438\u0442\u0435 \u0432\u0430\u043a\u0443\u0443\u043c\u043d\u0443\u044e \u043a\u0430\u043c\u0435\u0440\u0443, \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u0440\u0430\u0431\u043e\u0442\u0443 \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430, \u043f\u043e\u0432\u0442\u043e\u0440\u043d\u043e \u0438\u0437\u043c\u0435\u0440\u044c\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435 \u0438 \u0441\u0440\u0430\u0432\u043d\u0438\u0442\u0435 \u0435\u0433\u043e \u0441 \u0438\u0441\u0445\u043e\u0434\u043d\u044b\u043c \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435\u043c FAT); \u0438 \u0447\u0442\u043e \u0443\u0441\u0442\u0430\u0432\u043a\u0438 \u0440\u0435\u043b\u0435 \u0437\u0430\u0449\u0438\u0442\u044b \u0441\u043e\u0433\u043b\u0430\u0441\u043e\u0432\u0430\u043d\u044b \u0441 \u0437\u0430\u044f\u0432\u043b\u0435\u043d\u043d\u043e\u0439 \u043f\u043e\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c\u044e \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0439 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f. \u041b\u044e\u0431\u043e\u0435 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043d\u043e\u0435 \u043e\u0442\u043a\u043b\u043e\u043d\u0435\u043d\u0438\u0435 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u043d\u043e\u0433\u043e \u043d\u0430 \u043e\u0431\u044a\u0435\u043a\u0442\u0435 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432 \u043e\u0442 \u0438\u0441\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f FAT \u0442\u0440\u0435\u0431\u0443\u0435\u0442 \u0440\u0430\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043e \u043f\u043e\u0434\u0430\u0447\u0438 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u0430 \u043d\u0435 \u0430\u0434\u043c\u0438\u043d\u0438\u0441\u0442\u0440\u0430\u0442\u0438\u0432\u043d\u043e\u0433\u043e \u0440\u0430\u0437\u0431\u0438\u0440\u0430\u0442\u0435\u043b\u044c\u0441\u0442\u0432\u0430 \u043f\u043e\u0441\u043b\u0435 \u0432\u0432\u043e\u0434\u0430.<\/p>\n<p>\u0417\u0430\u0442\u0440\u0430\u0442\u044b \u043d\u0430 \u0441\u0442\u0440\u043e\u0433\u0443\u044e \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0443 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u044f IEC 62271-100 \u043c\u043d\u043e\u0433\u043e\u043a\u0440\u0430\u0442\u043d\u043e \u043e\u043a\u0443\u043f\u0430\u044e\u0442\u0441\u044f \u0437\u0430 \u0441\u0447\u0451\u0442 \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0451\u043d\u043d\u044b\u0445 \u043e\u0442\u043a\u0430\u0437\u043e\u0432, \u0441\u043d\u0438\u0436\u0435\u043d\u0438\u044f \u0441\u0442\u0440\u0430\u0445\u043e\u0432\u044b\u0445 \u0438 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u0432 \u0438 \u0443\u0432\u0435\u0440\u0435\u043d\u043d\u043e\u0441\u0442\u0438 \u0432 \u0442\u043e\u043c, \u0447\u0442\u043e \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c, \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0451\u043d\u043d\u0430\u044f \u0432 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438 \u0442\u0438\u043f\u043e\u0432\u044b\u0445 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439, \u0431\u0443\u0434\u0435\u0442 \u0432\u043e\u0441\u043f\u0440\u043e\u0438\u0437\u0432\u0435\u0434\u0435\u043d\u0430 \u0432 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u043f\u0440\u0438 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u0438 \u0442\u043e\u043a\u0430 \u041a\u0417.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quick Takeaway Confirm the project duty and applicable requirements for VCB before selection or service work. Use recorded inspection and test evidence instead of unsupported assumptions. Keep the final acceptance, maintenance, and handover documents with the equipment record. Procuring or manufacturing a 12 kV vacuum circuit breaker (VCB) without a structured compliance map to IEC [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4118,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-4123","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/4123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/comments?post=4123"}],"version-history":[{"count":3,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/4123\/revisions"}],"predecessor-version":[{"id":4268,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/posts\/4123\/revisions\/4268"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media\/4118"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/media?parent=4123"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/categories?post=4123"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ru\/wp-json\/wp\/v2\/tags?post=4123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}