{"id":2118,"date":"2025-12-15T16:44:21","date_gmt":"2025-12-15T16:44:21","guid":{"rendered":"https:\/\/xbrele.com\/?p=2118"},"modified":"2026-04-07T12:32:32","modified_gmt":"2026-04-07T12:32:32","slug":"what-is-vacuum-circuit-breaker-working-principle","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/what-is-vacuum-circuit-breaker-working-principle\/","title":{"rendered":"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB) \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9, \u0b85\u0ba4\u0bc1 \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf \u0bb5\u0bc7\u0bb2\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?"},"content":{"rendered":"\ufeff\n<div class=\"executive-summary\">\n    <h3>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd: \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8<\/h3>\n    <p>\n        \u0b85\u0ba8\u0bcd\u0ba4 <strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB)<\/strong> \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b89\u0bb2\u0b95\u0bb3\u0bb5\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 SF6 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.\n    <\/p>\n    <ul>\n        <li>\n            <strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0b95\u0bc8:<\/strong> \u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0b86\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd <strong>12 kV \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 40.5 kV \u0bb5\u0bb0\u0bc8<\/strong> \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba9\u0bb0\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1.\n        <\/li>\n        <li>\n            <strong>\u0bae\u0bc8\u0baf\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd:<\/strong> \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd <strong>\u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b85\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (&lt; 10\u207b\u2076 \u0baa\u0bbe\u0bb0\u0bcd).\n        <\/li>\n        <li>\n            <strong>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba8\u0ba9\u0bcd\u0bae\u0bc8:<\/strong> \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd (SF6 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8), \u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd (30,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b87\u0b9f\u0ba4\u0bcd\u0ba4\u0bc7\u0bb5\u0bc8.\n        <\/li>\n        <li>\n            <strong>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd:<\/strong> \u0b89\u0b9f\u0bcd\u0baa\u0bc1\u0bb1 \u0b89\u0bb2\u0bcb\u0b95 \u0b89\u0bb1\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd (\u0b8e.\u0b95\u0bbe., <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\">VS1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd<\/a>) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b95\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bb1\u0bc1\u0bae\u0bc2\u0b9f\u0bb2\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b8e.\u0b95\u0bbe., <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/zw32-vacuum-circuit-breaker\/\">ZW32 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd<\/a>).\n        <\/li>\n    <\/ul>\n    <p>\n        <em><strong>\u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd:<\/strong> ~8 \u0ba8\u0bbf\u0bae\u0bbf | <strong>\u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0bae\u0bbf\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, EPC-\u0b95\u0bb3\u0bcd, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/em>\n    <\/p>\n<\/div>\n\n\n\n<p><strong>\u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bcb\u0bb3\u0bcd:<\/strong> <a href=\"https:\/\/webstore.iec.ch\/publication\/6734\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 62271-100<\/a>, IEEE C37.04<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB) \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9? \u0b85\u0ba4\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/r4ByjQDZL40?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-introduction-why-vacuum-circuit-breakers-matter-in-modern-power-systems\">1. \u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0bae\u0bcd \u2013 \u0ba8\u0bb5\u0bc0\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd \u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b8f\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0bb5\u0bc8<\/h2>\n\n\n\n<p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd (MV) \u0bae\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf \u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bbf\u0bb2\u0bcd, \u201c\u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bb1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u201d \u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc8\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9, \u0bae\u0bc8\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbe\u0bb1\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bcd \u0bae\u0bc0\u0ba4\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9. \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb4\u0bc8\u0baf\u0bc8 \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0ba9\u0bc7 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b87\u0ba9\u0bbf \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8; \u0ba8\u0bb5\u0bc0\u0ba9 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0ba8\u0bbf\u0b95\u0bb4\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc8 (OPEX) \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bbf\u0bb2\u0bcd, <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\"><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf<\/strong><\/a> (VCB) \u0b86\u0ba9\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bcb\u0bb0\u0bbf\u0bb2\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. <strong>12 kV \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 40.5 kV<\/strong>. \u0baa\u0bb2 \u0ba4\u0b9a\u0bbe\u0baa\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b87\u0b9f\u0baa\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b89\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b87\u0b9f\u0bae\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4 VCB-\u0b95\u0bb3\u0bcd, \u0b87\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0ba9 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b86\u0ba3\u0bc8\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, SF\u2086 (\u0b9a\u0bb2\u0bcd\u0baa\u0bb0\u0bcd \u0bb9\u0bc6\u0b95\u0bcd\u0bb8\u0bbe\u0b83\u0baa\u0bcd\u0bb3\u0bc2\u0bb0\u0bc8\u0b9f\u0bc1) \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0bb5\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0bae\u0bbf\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b86\u0bb2\u0bc8 \u0bae\u0bc7\u0bb2\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd EPC \u0b92\u0baa\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe\u0bb0\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, VCB-\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0baf \u0bae\u0bc7\u0bb2\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bbe\u0ba9 \u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95\u0bbe\u0ba4\u0bc1. \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc7\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b8e\u0b83\u0b95\u0bc1 \u0b86\u0bb2\u0bc8, \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0ba4\u0bb0\u0bb5\u0bc1 \u0bae\u0bc8\u0baf\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0 \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1, VCB-\u0baf\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd, \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0baf \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf \u0b85\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0bb3\u0bc1\u0ba3\u0bb0\u0bcd\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-what-is-a-vacuum-circuit-breaker\">2. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9?<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b85\u0bb1\u0bc8 \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1 \u0b85\u0bb4\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bbe\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VI)<\/strong>. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 $10^{-4}$ Pa ($10^{-6}$ mbar)-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 VCB-\u0b90 \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0ba3\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95, \u0ba8\u0bbe\u0bae\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd <strong>\u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd<\/strong>. \u0bae\u0bb1\u0bcd\u0bb1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3 \u0b8a\u0b9f\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 (\u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b86\u0bb5\u0bbf, \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 SF\u2086) \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0ba9 \u0b85\u0baf\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bbe\u0baf\u0bc1 (\u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe) \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0bb2\u0bcd, \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3 \u0bb5\u0bbe\u0baf\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8. \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 <strong>\u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe<\/strong>, \u0baa\u0bbf\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd \u0ba4\u0bb0\u0bc1\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc7 \u0b86\u0bb5\u0bbf\u0baf\u0bbe\u0b95\u0bbf \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"definition-by-technical-contrast\">\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc8<\/h3>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 VCB \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd <em>\u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/em> \u0b85\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd <em>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/em>. \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd <a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor-vs-vacuum-circuit-breaker-medium-voltage-panel\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd vs \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd<\/a> \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0ba8\u0bc1\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (OCBs):<\/strong> OCB-\u0b95\u0bb3\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8 \u0ba8\u0bc0\u0bb0\u0bbe\u0b95\u0bcd\u0b95\u0bbf, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95 \u0b92\u0bb0\u0bc1 \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0b95\u0bc1\u0bae\u0bbf\u0bb4\u0bbf\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0ba4\u0bc0 \u0b85\u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0bcd\u0baa\u0928\u0940\u0915\u0943\u0924 \u0b8e\u0b9a\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. VCB-\u0b95\u0bb3\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bbe\u0b95 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li><strong>\u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd (ACBs):<\/strong> ACB-\u0b95\u0bb3\u0bcd \u0bb5\u0bb3\u0bbf\u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0b95\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. 12kV-\u0b90\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3, \u0b92\u0bb0\u0bc1 ACB-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc0\u0b9a\u0bcd\u0b9a\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0baf\u0bcd\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0ba8\u0bb5\u0bc0\u0ba9, \u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0b9f\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb5\u0bcd\u0bb5\u0bbe\u0ba4\u0ba4\u0bbe\u0b95 \u0b86\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95 SF\u2086 \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> SF\u2086 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bae\u0bb1\u0bc8 \u0bb5\u0bbe\u0baf\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0bb4\u0bbf\u0b95\u0bb3\u0bc8 \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95 \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, SF\u2086 \u0b92\u0bb0\u0bc1 \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 (GWP ~23,500) \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd, SF\u2086 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd (\u0ba4\u0bc2\u0bb3\u0bcd\u0b95\u0bb3\u0bcd) \u0ba8\u0b9a\u0bcd\u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0bc8\u0baf\u0bb5\u0bc8, \u0b87\u0ba4\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. VCB-\u0b95\u0bb3\u0bcd \u0b87\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b95\u0bb5\u0bc7 \u201c\u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0bb5\u0bc8\u201d \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bc1\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart.webp\" alt=\"xbrele-SF6 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bc8 \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8.\" class=\"wp-image-2120\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vcb-vs-sf6-vs-oil-breaker-comparison-chart-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 <strong>\u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8<\/strong> \u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bcd: \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bcb\u0ba4\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd. \u0bae\u0bcb\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd, \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd \u0baa\u0ba9\u0bbf\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0bb5\u0bc8 (\u0baa\u0bbf\u0bb3\u0bb5\u0bc1)\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1 \u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0ba4\u0bc2\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 SF\u2086-\u0b90 \u0bb5\u0bbf\u0b9f \u0bae\u0bbf\u0b95 \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-main-components-of-a-vacuum-circuit-breaker\">3. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u201c\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u201d \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2; \u0b85\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0b95 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1. \u0b85\u0ba4\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd, \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vacuum-interrupter-the-bottle\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (\u201c\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd\u201d)<\/h3>\n\n\n\n<p>VCB-\u0baf\u0bbf\u0ba9\u0bcd \u0b87\u0ba4\u0baf\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b85\u0ba4\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b9a\u0bae\u0bb0\u0b9a\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bb0 \u0b85\u0bb2\u0bc1\u0bae\u0bbf\u0ba9\u0bbe \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, \u0b89\u0bb2\u0bcb\u0b95 \u0bae\u0bc1\u0ba9\u0bc8 \u0bae\u0bc2\u0b9f\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0bb8\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 20-30 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0b95\u0bbf\u0bb0\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb2\u0bcd \u0bae\u0bc6\u0b9f\u0bcd\u0b9f\u0bb2\u0bb0\u0bcd\u0b9c\u0bbf):<\/strong> \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc2\u0baf \u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1; \u0b85\u0bb5\u0bc8 \u0b92\u0ba9\u0bcd\u0bb1\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd. \u0ba8\u0bb5\u0bc0\u0ba9 VCB-\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 <strong>\u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1-\u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd (CuCr)<\/strong> \u0b95\u0bb2\u0bb5\u0bc8 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 75% Cu \/ 25% Cr). \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bc1 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0bbf\u0b99\u0bcd\u0b95\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u201c\u0b95\u0bc6\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0b99\u0bcd\u201d (\u0ba4\u0bb5\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0ba4\u0bb2\u0bcd) \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bbf\u0baf\u0bb2\u0bcd (AMF vs. RMF):<\/strong> \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb5\u0bb0\u0bae\u0bcd.\n<ul class=\"wp-block-list\">\n<li><em>\u0b86\u0bb0\u0bcd\u0b8e\u0bae\u0bcd\u0b8e\u0b83\u0baa\u0bcd (\u0bb5\u0b9f\u0bcd\u0b9f\u0b95\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba9\u0bcd):<\/em> \u0b89\u0bb3\u0bcd\u0bb3\u0bc2\u0bb0\u0bcd \u0b89\u0bb0\u0bc1\u0b95\u0bc1\u0ba4\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb2\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><em>AMF (\u0b85\u0b9a\u0bcd\u0b9a \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba9\u0bcd):<\/em> \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95 \u0b92\u0bb0\u0bc1 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0b92\u0bb0\u0bc1 \u201c\u0b9a\u0bbf\u0ba4\u0bb1\u0bbf\u0baf\u201d \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0bae\u0bc1\u0bb4\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bae\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bb0\u0bb5\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0b85\u0ba4\u0bbf\u0b95 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd-\u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (\u0b8e.\u0b95\u0bbe., 40kA, 50kA) AMF \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong> \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <em>(\u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b95: <\/em><a href=\"https:\/\/xbrele.com\/ta\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\"><em>\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/em><\/a><em> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd).<\/em><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view.webp\" alt=\"xbrele-\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bae\u0bcd \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bc6\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bcb\u0ba9 \u0ba4\u0bcb\u0bb1\u0bcd\u0bb1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bb5\u0bb0\u0bcd, CuCr \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.\" class=\"wp-image-2121\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-circuit-breaker-internal-exploded-view-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-bellows\">\u0ba4\u0bc1\u0bb5\u0bb3\u0bc8<\/h3>\n\n\n\n<p>\u0b86\u0bb0\u0bae\u0bcd\u0baa\u0b95\u0bbe\u0bb2 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd, \u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba4 \u0b8e\u0b83\u0b95\u0bc1, \u0b85\u0b95\u0bcd\u0b95\u0bbe\u0bb0\u0bcd\u0b9f\u0bbf\u0baf\u0ba9\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0b95\u0bc1\u0bb4\u0bbe\u0baf\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc8 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 6 \u0bae\u0bbf\u0bae\u0bc0 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 20 \u0bae\u0bbf\u0bae\u0bc0 \u0bb5\u0bb0\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc8\u0baf\u0bc8 \u0b89\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd \u0baa\u0baf\u0ba3\u0bbf\u0b95\u0bcd\u0b95 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bb5\u0bc0\u0ba9 \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0bcb-\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9 <strong>M2 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (10,000 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30,000 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd), \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operating-mechanism\">\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8<\/h3>\n\n\n\n<p>SF\u2086 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1 \u0ba4\u0bc2\u0bb0\u0bae\u0bcd (\u0ba4\u0bc2\u0bb0\u0bae\u0bcd) \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0b87\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0ba4\u0bc2\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bae\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b87\u0bb2\u0bc8\u0baf\u0bc1\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc7\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd:<\/strong> \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8. \u0b92\u0bb0\u0bc1 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bc8\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1\u0bbf, \u0b85\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b85\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0b9a\u0bc8:<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb0\u0ba8\u0bcd\u0ba4\u0bb0 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0b9a\u0bcb\u0bb2\u0bbf\u0ba9\u0bbe\u0baf\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1. \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd, \u0b87\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"primary-conductors-insulation-system\">\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bae\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\"><strong>VS1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd<\/strong><\/a>, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0bb0\u0bc6\u0b9a\u0bbf\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bb5\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u201c\u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bae\u0bcd\u0baa\u0bae\u0bcd\u201d \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd, \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd \u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bc8 \u0ba4\u0bc2\u0b9a\u0bbf, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0ba4\u0bcd\u0ba4\u0bc1, \u0b85\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8a\u0bb0\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc2\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-auxiliary-circuits\">\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bc1-\u0bae\u0bc2\u0b9f\u0bbf-\u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b8e\u0ba9\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1), \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd\u0bb8\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd SCADA \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bc2\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-how-does-a-vacuum-circuit-breaker-work\">4. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/h2>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0ba8\u0bcd\u0ba4\u0baf\u0bae\u0bcd\u2014\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95, ...\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0baa\u0ba8\u0bcd\u0ba4\u0baf\u0bae\u0bcd. <strong>\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (TRV)<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b8e\u0bb4\u0bc1\u0ba4\u0bb2\u0bcd <strong>\u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8\u0baa\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0ba9\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"normal-closed-condition\">\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0ba8\u0bbf\u0bb2\u0bc8<\/h3>\n\n\n\n<p>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd\u0bb8\u0bcd, \u03bc\u03a9 \u0b87\u0bb2\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1). \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95, \u0bae\u0bbf\u0b95\u0bc1\u0ba8\u0bcd\u0ba4 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bb5\u0bbf\u0b9a\u0bc8) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"fault-detection-and-trip-command\">\u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bb3\u0bc8<\/h3>\n\n\n\n<p>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0b9f\u0ba9\u0bcd, \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc8 \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0bbf \u0b87\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1\u2014\u0bae\u0bbf\u0b95 \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b8e\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd; \u0bae\u0bbf\u0b95 \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"arc-extinction-the-current-zero-phenomenon\">\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1: \u201c\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bae\u0bc8 \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0bae\u0bcd\u201d \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0b9f\u0bc8\u0b9a\u0bbf \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0b89\u0bb0\u0bc1\u0b95\u0bbf \u0bb5\u0bc6\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe\u0baa\u0bcd \u0baa\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b9a\u0bbf\u0ba4\u0bb1\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8:<\/strong> \u0ba8\u0ba9\u0bcd\u0b95\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f AMF \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba8\u0bbf\u0baf\u0bbf\u0bb2\u0bcd, \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b89\u0bb0\u0bc1\u0b95\u0bc1\u0ba4\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0bae\u0bcd:<\/strong> \u0b8f\u0b9a\u0bbf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1 100 \u0bae\u0bc1\u0bb1\u0bc8 (50Hz) \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bc6\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0ba9\u0bcd\u0bb1\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9 \u0938\u0902\u0918\u0ba9\u0bb5\u0bc1:<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0b95\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0bb5\u0bbf\u0bb2\u0bcd \u0b85\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd. \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb3\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0b87\u0bb0\u0bc1\u0bae\u0bbf\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bc0\u0b9f\u0bcd\u0b9a\u0bbf:<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b85\u0ba4\u0ba9\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bc1\u0bb5\u0bc8 \u0b95\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0b9f\u0bcd\u0b9f \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc0\u0b9f\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1, \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb0\u0bc1\u0bae\u0bcd TRV-\u0b90 \u0bb5\u0bbf\u0b9f \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb0\u0bae\u0bbe\u0ba9\u0ba4\u0bc1. \u0b87\u0bb2\u0bcd\u0bb2\u0bc8\u0baf\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 <strong>\u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0b9a\u0bcd\u0b9a\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/strong> \u0ba8\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9 \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bbe\u0ba9\u0bcd \u0b85\u0ba4\u0bc1 \u0b87\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0ba4\u0bbf\u0bb1\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd. \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0baf \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bcb\u0bb3\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd <a href=\"https:\/\/en.wikipedia.org\/wiki\/Paschen%27s_law\" target=\"_blank\" rel=\"noopener\">\u0baa\u0bbe\u0bb7\u0ba9\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf<\/a> \u0baa\u0bbf\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0b87\u0ba4\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram.webp\" alt=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f-\u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd-\u0b95\u0ba4\u0bbf\u0bb0\u0bcd-\u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1-\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8-\u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" class=\"wp-image-2122\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-arc-extinction-process-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-vacuum-circuit-breaker-internal-structure-exploded-view\">5. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bcb\u0bb1\u0bcd\u0bb1\u0bae\u0bcd)<\/h2>\n\n\n\n<p><em>(\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1: \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95, \u0baa\u0b95\u0bc1\u0ba4\u0bbf 3-\u0b87\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3, \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1).<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-vacuum-circuit-breaker-vs-other-technologies\">6. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/h2>\n\n\n\n<p>\u0b95\u0bc0\u0bb4\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8, MV-\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bbe\u0b95 VCB \u0b8f\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, HV\/EHV-\u0b95\u0bcd\u0b95\u0bbe\u0b95 SF\u2086 \u0b8f\u0ba9\u0bcd \u0b92\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bae\u0bcd\u0b9a\u0bae\u0bcd<\/th><th>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB)<\/th><th>SF\u2086 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd<\/th><th>\u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf (ACB)<\/th><\/tr><tr><td><strong>\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b8a\u0b9f\u0b95\u0bae\u0bcd<\/strong><\/td><td>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd ($&lt;10^{-6}$ \u0baa\u0bbe\u0bb0\u0bcd)<\/td><td>\u0b95\u0ba8\u0bcd\u0ba4\u0b95 \u0bb9\u0bc6\u0b95\u0bcd\u0bb8\u0bbe\u0b83\u0baa\u0bcd\u0bb3\u0bc2\u0bb0\u0bc8\u0b9f\u0bc1 \u0bb5\u0bbe\u0baf\u0bc1<\/td><td>\u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0bae\u0bcd<\/td><\/tr><tr><td><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8<\/strong><\/td><td>\u0b85\u0ba4\u0bbf\u0b95 (10,000 \u2013 30,000)<\/td><td>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 (2,000 \u2013 5,000)<\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4<\/td><\/tr><tr><td><strong>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/strong><\/td><td>\u0bb5\u0bbe\u0bb4\u0bcd\u0ba8\u0bbe\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc8\u0baf\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/td><td>\u0bb5\u0bbe\u0baf\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8<\/td><td>\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0bb8\u0bcd\u0b95\u0bc2\u0b9f\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd<\/td><\/tr><tr><td><strong>\u0b85\u0bb3\u0bb5\u0bc1 \/ \u0ba4\u0b9f\u0bae\u0bcd<\/strong><\/td><td>\u0bae\u0bbf\u0b95\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf<\/td><td>\u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/td><td>\u0baa\u0bc6\u0bb0\u0bbf\u0baf \/ \u0b95\u0ba9\u0bae\u0bbe\u0ba9<\/td><\/tr><tr><td><strong>\u0ba4\u0bc0 \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd<\/strong><\/td><td>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 (\u0ba4\u0bc0\u0baa\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bbe\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1)<\/td><td>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 (\u0b85\u0baf\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1)<\/td><\/tr><tr><td><strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd<\/strong><\/td><td><strong>\u0baa\u0b9a\u0bcd\u0b9a\u0bc8<\/strong> (\u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0b89\u0bae\u0bbf\u0bb4\u0bcd\u0bb5\u0bc1)<\/td><td><strong>\u0b85\u0ba4\u0bbf\u0b95 \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong> (\u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1)<\/td><td>\u0ba8\u0b9f\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8<\/td><\/tr><tr><td><strong>\u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd<\/strong><\/td><td>\u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 (\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bb5\u0bc7\u0b95\u0bae\u0bcd)<\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4<\/td><td>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0\u0bae\u0bbe\u0ba9\u0ba4\u0bc1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-typical-applications-of-vacuum-circuit-breakers\">7. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"substations-utilities\">\u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0baa\u0b95\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (11kV \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 33kV \u0bb5\u0bb0\u0bc8) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd VCB-\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba4\u0ba9\u0bcd \u0b89\u0baf\u0bb0\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0 \u0b86\u0bb3\u0bbf\u0bb2\u0bcd\u0bb2\u0bbe \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"industrial-plants-motor-switching\">\u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0b95\u0bb3\u0bcd (\u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd)<\/h3>\n\n\n\n<p>\u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 VCB \u0b95\u0bcb\u0b9f\u0bcd\u0b9f\u0bc8. \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b86\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd \u0b86\u0b83\u0baa\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. VCB-\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0b86\u0baf\u0bbf\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>\u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/em> \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. <strong>\u0bae\u0bc6\u0baf\u0bcd\u0ba8\u0bbf\u0b95\u0bb0\u0bcd \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd<\/strong> \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb2 \u0bae\u0bb1\u0bc1-\u0b8f\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0b95\u0bb3\u0bcd. \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb5\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd <strong>\u0b86\u0bb0\u0bcd\u0b9a\u0bbf \u0bb8\u0bcd\u0ba9\u0baa\u0bcd\u0baa\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 VCB-\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bcd \u0b9c\u0bbf\u0b99\u0bcd\u0b95\u0bcd \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0b9a\u0bb0\u0bcd\u0b9c\u0bcd \u0b85\u0bb0\u0bc6\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/vs1-vacuum-circuit-breaker\/\"><strong>VS1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd<\/strong><\/a>\u0b89\u0b9f\u0bcd\u0baa\u0bc1\u0bb1 \u0b89\u0bb2\u0bcb\u0b95 \u0b89\u0bb1\u0bc8\u0b9a\u0bc2\u0bb4\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 (KYN28 \u0bb5\u0b95\u0bc8 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1) \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mining-arc-furnaces\">\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b89\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0bae\u0bbf\u0ba9\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b89\u0bb2\u0bc8\u0b95\u0bb3\u0bcd (EAF) \u0b8e\u0ba9\u0bcd\u0baa\u0bb5\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0b9f\u0bcd\u0b9f \u0b9a\u0bbf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bae\u0bcd, \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 100 \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <em>\u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bc8\u0b95\u0bcd\u0b95\u0bc1<\/em>. VCB-\u0b95\u0bb3\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 (\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd) \u0b87\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8. \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbe\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba4\u0bcd \u0ba4\u0bc2\u0b9a\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"rmu-and-ring-networks\">\u0b86\u0bb0\u0bcd\u0b8e\u0bae\u0bcd\u0baf\u0bc2 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb0\u0bbf\u0b99\u0bcd \u0ba8\u0bc6\u0b9f\u0bcd\u0bb5\u0bca\u0bb0\u0bcd\u0b95\u0bcd\u0bb8\u0bcd<\/h3>\n\n\n\n<p>\u0bb8\u0bcd\u0bae\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/zw32-vacuum-circuit-breaker\/\"><strong>ZW32 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bbf<\/strong><\/a>: \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 (\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) \u0ba4\u0bbe\u0ba9\u0bbe\u0b95\u0bb5\u0bc7 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u201c\u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u201d \u0b86\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/zw20-vacuum-circuit-breaker\/\"><strong>ZW20 \u0b95\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bbf<\/strong><\/a>: \u0b87\u0ba4\u0bc1 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbe\u0baf\u0bc1-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0b9f\u0bcd\u0b9f\u0b9f\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bbf\u0b9f-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0b9f\u0bcd\u0b9f\u0b9f\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-1024x559.webp\" alt=\"\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba9\u0bcd\u0b95\u0bbf\u0bb0\u0bc0\u0b9f\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 ZW32 \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd.\" class=\"wp-image-2123\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-1024x559.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-1536x838.webp 1536w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-2048x1117.webp 2048w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/zw32-outdoor-pole-mounted-vacuum-circuit-breaker-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"8-faqs-engineering-maintenance-insights\">8. \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd: \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>1. \u201c\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd\u201d \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1 \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0baf\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0b85\u0ba4\u0bc1 \u0b9a\u0bbf\u0bb2 \u0b9a\u0bae\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b86\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc8 \u0b85\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd. <em>\u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1<\/em> \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0bae\u0bcd (\u0b8e.\u0b95\u0bbe., 0A-\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 3A \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 4A-\u0bb2\u0bcd), \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 (\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0baa\u0bcb\u0ba4\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bc1\u0bae\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u201c\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd\u201d, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1, \u0b89\u0baf\u0bb0\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bb5\u0bc0\u0ba9 CuCr \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b8f\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>2. \u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bcb\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong> \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bc7\u0bb0\u0bbf\u0bb2\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bbf\u0b9f\u0bbe\u0bb0\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8):<\/strong> \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0b89\u0baf\u0bb0\u0bcd DC \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (\u0b8e.\u0b95\u0bbe., 12kV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 40kV DC) \u0b95\u0bca\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0baf\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0baf\u0bbe\u0ba4\u0bc1. \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0b95\u0b9a\u0bbf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b85\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bc0\u0baa\u0bcd\u0baa\u0bca\u0bb1\u0bbf \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 (\u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8:<\/strong> \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 (\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd\u0bb8\u0bbf\u0bb2\u0bcd) \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p><strong>3. VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u201c\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bbf\u0b99\u0bcd\u201d \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b8f\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1?<\/strong> \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc8 \u0ba4\u0bbe\u0ba9\u0bbe\u0b95\u0bb5\u0bc7 \u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u201c\u0ba4\u0bbf\u0bb1-\u0bae\u0bc2\u0b9f\u0bc1-\u0ba4\u0bbf\u0bb1\u201d (O-C-O) \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>4. DC \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 VCB-\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbe\u0bae\u0bbe?<\/strong> \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95, \u0b87\u0bb2\u0bcd\u0bb2\u0bc8. VCB-\u0b95\u0bb3\u0bcd AC \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b92\u0bb0\u0bc1 DC \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0b95\u0bb5\u0bc7 \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0baa\u0bcd\u0baa\u0ba4\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8. DC \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4, \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u201c\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b89\u0b9f\u0bcd\u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\u201d \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>5. \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0ba8\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd?<\/strong> \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b87\u0bb4\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd. \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8 \u0b92\u0bb0\u0bc1 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bb1\u0bcd\u0bb1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1 \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b9a\u0bbf\u0ba4\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd\u0ba4\u0bbe\u0ba9\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (M2 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1) \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>6. \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 VCB-\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9\u0bb5\u0bc8\u0baf\u0bbe?<\/strong> \u0b86\u0bae\u0bcd, \u0b85\u0bb5\u0bc8 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bb5\u0bc8 (\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 C2 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1). \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4, \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b85\u0bb2\u0bc8-\u0bae\u0bc1\u0ba9\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0bb2 \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"9-conclusion-cta\">9. \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 + \u0b85\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbe\u0ba9\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bb5\u0bc0\u0ba9 \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0ba4\u0bc1\u0b95\u0bc6\u0bb2\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0b95 \u0b89\u0bb0\u0bc1\u0bb5\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b85\u0ba4\u0ba9\u0bcd \u0b86\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0ba4\u0bb1\u0bcd\u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0ba9\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u2014\u0b85\u0ba4\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0bcc\u0ba4\u0bc0\u0b95 \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd: \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0bb3\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb1\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1.<\/p>\n\n\n\n<p>\u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 VCB-\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b9a\u0bae\u0bae\u0bbe\u0b95 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8. \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd, CuCr \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd 5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 30 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bae\u0bb0\u0b9a\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bbe\u0ba4\u0bc0\u0bb0\u0bcd\u0b95\u0bb3\u0bcd.<\/strong> \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bcd. XBRELE, \u0b9a\u0bb5\u0bbe\u0bb2\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0baa\u0bc1\u0ba3\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbe?<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, OEM \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0baf\u0ba9\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf \u0bb5\u0bbf\u0bb5\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0baa\u0bcd\u0bb3\u0bc8\u0baf\u0bb0\u0bcd \u0bb5\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd XBRELE-\u0b87\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0bc1\u0bb4\u0bc1\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd. <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker-manufacturers\/\"><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd<\/strong><\/a>, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bc8 \u0b85\u0ba4\u0ba9\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker-ratings\/\">\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/a>.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Executive Summary: Engineering Quick View The Vacuum Circuit Breaker (VCB) is the globally accepted standard for medium-voltage switching, offering a maintenance-free and environmentally safe alternative to SF6 and Oil technologies. Voltage Class: Dominant in the 12 kV to 40.5 kV range for substations and heavy industry. Core Technology: Utilizes Metal Vapor Arc Extinction in [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2119,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2118","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2118","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2118"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2118\/revisions"}],"predecessor-version":[{"id":3538,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2118\/revisions\/3538"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2119"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2118"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2118"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2118"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}