{"id":2126,"date":"2025-12-16T12:58:10","date_gmt":"2025-12-16T12:58:10","guid":{"rendered":"https:\/\/xbrele.com\/?p=2126"},"modified":"2026-04-07T15:12:45","modified_gmt":"2026-04-07T15:12:45","slug":"sf6-load-break-switch-working-principle","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/sf6-load-break-switch-working-principle\/","title":{"rendered":"SF6 \u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd (LBS) \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9? \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf"},"content":{"rendered":"<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"SF6 \u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9? LBS \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VCB \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/fvuUe-9gqZY?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #2c3e50; padding: 20px; margin: 20px 0; font-family: sans-serif; box-shadow: 0 2px 4px rgba(0,0,0,0.05);\"> <h3 style=\"color: #2c3e50; margin-top: 0; display: flex; align-items: center;\"> <span style=\"font-size: 1.2em; margin-right: 10px;\"><\/span> \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd <\/h3> <ul style=\"list-style-type: none; padding-left: 0; margin-bottom: 0;\"> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 LBS \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VCB \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1:<\/strong> \u0b92\u0bb0\u0bc1 LBS \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 <em>\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bc7\u0bb2\u0bbe\u0ba3\u0bcd\u0bae\u0bc8<\/em> (\u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1), \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd \u0b92\u0bb0\u0bc1 VCB \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 <em>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd<\/em> \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95. <\/li> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 3-\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> \u0ba8\u0bb5\u0bc0\u0ba9 RMU-\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0bae\u0ba9\u0bbf\u0ba4\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 (\u0b86\u0ba9\u0bcd \u2192 \u0b86\u0b83\u0baa\u0bcd \u2192 \u0b8e\u0bb0\u0bcd\u0ba4\u0bcd) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <\/li> <li style=\"margin-bottom: 12px; border-bottom: 1px solid #e9ecef; padding-bottom: 12px;\"> <strong>\ud83d\udd39 \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b92\u0bb0\u0bc1 LBS \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd, \u0b85\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95 HRC \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd (\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd-\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1) \u0b95\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0b9f\u0bcd\u0b9f \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <\/li> <li> <strong>\ud83d\udd39 \u0b86\u0bb3\u0bc1\u0bae\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <strong>\u0b90\u0b87\u0b9a\u0bbf 62271-103<\/strong> (\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd <strong>\u0b90\u0b87\u0b9a\u0bbf 62271-105<\/strong> (\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd-\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd). <\/li> <\/ul> <\/div> <!-- END HTML BLOCK -->\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-introduction-the-lbs-vs-vcb-dilemma-in-network-design\">1. \u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0bae\u0bcd: \u0ba8\u0bc6\u0b9f\u0bcd\u0bb5\u0bca\u0bb0\u0bcd\u0b95\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd LBS \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VCB \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb4\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/h2>\n\n\n\n<p>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bb0\u0bbf \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 (SLD) \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0bb4\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1: <strong>\u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd (LBS) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd (VCB) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0ba8\u0bbe\u0bae\u0bcd \u0b8e\u0b99\u0bcd\u0b95\u0bc7 \u0b92\u0bb0\u0bc1 \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0baf\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1, \u0b85\u0bb5\u0bc8 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc7 \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bcb\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bcd \u0b85\u0bae\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. <a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/switchgear-components\/\"><strong>\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong><\/a>. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0b87\u0b99\u0bcd\u0b95\u0bc1 \u0ba4\u0bb5\u0bb1\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b9a\u0bca\u0bb1\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2; \u0b85\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b87\u0b9f\u0bb0\u0bcd. VCB-\u0b95\u0bb3\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0bb5\u0bbf\u0bb5\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd 300% \u0bb5\u0bb0\u0bc8) \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd, \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b92\u0bb0\u0bc1 LBS-\u0b90\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0bb5\u0bbf\u0bb5\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0ba4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0cbf\u0c97\u0cc6 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (MV) \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0ba8\u0bcd\u0ba4 <a href=\"https:\/\/xbrele.com\/ta\/what-is-vacuum-circuit-breaker-working-principle\/\"><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB)<\/strong><\/a> \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd <strong>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8<\/strong>\u2014\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd-\u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0b8e.\u0b95\u0bbe., 20kA, 31.5kA).<\/li>\n\n\n\n<li>\u0b85\u0ba8\u0bcd\u0ba4 <a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/sf6-load-break-switch\/\"><strong>SF6 \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd<\/strong><\/a> \u0b92\u0bb0\u0bc1 <strong>\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bc7\u0bb2\u0bbe\u0ba3\u0bcd\u0bae\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf<\/strong>\u2014\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0bbf\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd, \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bb0\u0bc8, SF6 LBS-\u0b87\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0baf\u0ba4\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0b85\u0ba4\u0ba9\u0bcd \u0b89\u0bb3\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd, \u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b95\u0bb3\u0bcd (RMUs)-\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0b90\u0b87\u0b9a\u0bbf 62271<\/strong> \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-defining-the-sf6-load-break-switch-iec-62271-103\">2. SF6 \u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd (IEC 62271-103)<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 <strong>SF6 \u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd<\/strong> \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95, \u0b95\u0b9f\u0ba4\u0bcd\u0ba4 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b92\u0bb0\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0b95, \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0b90\u0b87\u0b9a\u0bbf 62271-103<\/strong>, \u0b85\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd <strong>\u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1<\/strong> \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0ba4\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (\u0b92\u0bb0\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc0\u0ba4\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1) \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0b95, \u0b85\u0ba4\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bc1\u0bae\u0bcd <strong>\u0b89\u0b9f\u0bc8<\/strong> \u0b85\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-engineering-reality-of-load-breaking\">\u201c\u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b99\u0bcd\u201d \u0b87\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0baf\u0ba4\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bae\u0bcd\u201d<\/h3>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0ba4\u0bae\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0bb3\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb4\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bcb\u0bae\u0bcd:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc1\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (\u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd):<\/strong> \u0b87\u0ba4\u0bc1 \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 (\u0b8e.\u0b95\u0bbe., 24kV-\u0bb2\u0bcd 630A) \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. SF6 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b8a\u0b9f\u0b95\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b87\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8 \u0b85\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0baa\u0bbf\u0bb4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd):<\/strong> \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8\u0b9e\u0bb0\u0bcd \u0ba4\u0bb1\u0bcd\u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b86\u0ba9 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bae\u0bc0\u0ba4\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8 \u0bae\u0bc2\u0b9f\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd, \u0b85\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1. \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8, \u0b85\u0ba4\u0bc1 \u0b85\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0baf\u0bbf\u0ba9\u0bcd (\u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95, 50kA \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd) \u0bae\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bbf\u0ba9\u0bc8 (\u0b87\u0b9f\u0bc8\u0bae\u0bbf\u0ba9\u0bcd\u0bae \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf):<\/strong> \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b85\u0ba4\u0bc1 \u0b89\u0ba8\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8 (BIL) \u0baa\u0bc2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1, \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0ba3\u0bbf\u0baa\u0bc1\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-hard-limit-it-is-not-a-breaker\">\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1: \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b89\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b85\u0bb2\u0bcd\u0bb2<\/h3>\n\n\n\n<p>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bcd: <strong>\u0b92\u0bb0\u0bc1 LBS \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1.<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1-\u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0bbf\u0bb2\u0bcb-\u0b86\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8. \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 LBS-\u0b90\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bbf\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd\u0ba4\u0bbe\u0ba9\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 LBS \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b89\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <strong>HRC \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bcd<\/strong>. \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf \u0b86\u0bb4\u0bae\u0bbe\u0b95 \u0b85\u0bb1\u0bbf\u0baf, \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. <a href=\"https:\/\/www.electropedia.org\/iev\/iev.nsf\/display?openform&amp;ievref=441-14-10\" target=\"_blank\" rel=\"noopener\"><strong>IEC \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bcb\u0baa\u0bc6\u0b9f\u0bbf\u0baf\u0bbe (\u0b9a\u0bb0\u0bcd\u0bb5\u0ba4\u0bc7\u0b9a \u0bae\u0bbf\u0ba9\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bca\u0bb1\u0bcd\u0b95\u0bb3\u0b9e\u0bcd\u0b9a\u0bbf\u0baf\u0bae\u0bcd)<\/strong><\/a> \u201c\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd-\u0b9f\u0bbf\u0bb8\u0bcd\u0b95\u0ba9\u0bc6\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd\u201d \u0b95\u0bc1\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bca\u0bb1\u0bcd\u0b95\u0bb3\u0b9e\u0bcd\u0b9a\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-the-physics-of-sf6-why-it-dominated-for-40-years\">3. SF6-\u0b87\u0ba9\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd: 40 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0b86\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0ba8\u0bbe\u0bae\u0bcd \u0b8f\u0ba9\u0bcd \u0b87\u0ba9\u0bcd\u0ba9\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bcb\u0bae\u0bcd <strong>\u0b95\u0ba8\u0bcd\u0ba4\u0b95 \u0bb9\u0bc6\u0b95\u0bcd\u0bb8\u0bbe\u0b83\u0baa\u0bcd\u0bb3\u0bc2\u0bb0\u0bc8\u0b9f\u0bc1 (SF6)<\/strong> \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd? \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd, \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b8a\u0b9f\u0b95\u0bae\u0bbe\u0b95 \u0b85\u0ba4\u0bc1 \u0baa\u0bcc\u0ba4\u0bc0\u0b95 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b95\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0b95\u0bb0\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-electronegativity-and-electron-attachment\">1. \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0bb5\u0bc1<\/h3>\n\n\n\n<p>SF6 \u0b92\u0bb0\u0bc1 \u201c\u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bc6\u0b95\u0b9f\u0bcd\u0b9f\u0bbf\u0bb5\u0bcd\u201d \u0bb5\u0bbe\u0baf\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd, \u0b85\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b88\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9. \u0b92\u0bb0\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 (\u0b87\u0ba4\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b93\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd), SF6 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b95\u0ba9\u0bae\u0bbe\u0ba9 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bcd \u0b85\u0baf\u0ba9\u0bbf\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n\n\n\n<p style=\"text-align: center; font-family: 'Times New Roman', serif; font-size: 1.3em; margin: 20px 0;\"> \u0b8e\u0bb8\u0bcd\u0b9a\u0bbf\u0b8e\u0b83\u0baa\u0bcd<sub>6<\/sub> + \u0b88<sup>\u2013<\/sup> \u2192 SF<sub>6<\/sub><sup>\u2013<\/sup> <\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0b95\u0ba9 \u0b85\u0baf\u0ba9\u0bbf\u0b95\u0bb3\u0bcd \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bb5\u0bc8, \u0b87\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bb3\u0bb5\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8, \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bb4\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0bae\u0bcd\u0baa\u0b9f\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-thermal-conductivity-at-high-temperatures\">2. \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd<\/h3>\n\n\n\n<p>SF6 \u0b92\u0bb0\u0bc1 \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0baa\u0ba3\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b85\u0ba4\u0bbe\u0bb5\u0ba4\u0bc1 \u0b85\u0ba4\u0ba9\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd (\u0b9a\u0bc1\u0bae\u0bbe\u0bb0\u0bcd 2000K\u20133000K) \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0b89\u0baf\u0bb0\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1 <strong>\u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8\u0baa\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1<\/strong>\u2014\u0b8f\u0b9a\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u201c\u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u201d \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0ba8\u0bcd\u0ba4 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b85\u0ba4\u0ba9\u0bcd \u0bae\u0bc0\u0ba4\u0bc1 \u0b8f\u0bb1\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f (\u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd) \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0ba4\u0ba9\u0ba4\u0bc1 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-chemical-recombination\">3. \u0bb5\u0bc7\u0ba4\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bb1\u0bc1\u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n\n\n\n<p>\u0b95\u0bbe\u0bb0\u0bcd\u0baa\u0ba9\u0bcd \u0b95\u0b9a\u0b9f\u0bbe\u0b95 \u0b9a\u0bbf\u0ba4\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b93\u0b9a\u0bcb\u0ba9\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0baa\u0bcb\u0bb2\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, SF6 \u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0bbf\u0bb2\u0bcd \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p style=\"text-align: center; font-family: 'Times New Roman', serif; font-size: 1.3em; margin: 20px 0;\"> \u0b8e\u0bb8\u0bcd\u0b9a\u0bbf\u0b8e\u0b83\u0baa\u0bcd<sub>6<\/sub> \u2194 S + 6F <\/p>\n\n\n\n<p>\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bb5\u0bc1\u0b9f\u0ba9\u0bcd, \u0b95\u0ba8\u0bcd\u0ba4\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b83\u0baa\u0bcd\u0bb3\u0bc2\u0bb0\u0bbf\u0ba9\u0bcd \u0b85\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 SF6 \u0b86\u0b95 \u0bae\u0bbe\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4 \u201c\u0b9a\u0bc1\u0baf-\u0b95\u0bc1\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u201d \u0baa\u0ba3\u0bcd\u0baa\u0bc1, \u0b92\u0bb0\u0bc1 \u0b9a\u0bc0\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f LBS-\u0b90 \u0bb5\u0bbe\u0baf\u0bc1 \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd 20+ \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-the-design-logic-why-rmus-rely-on-lbs\">4. \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd: RMU-\u0b95\u0bb3\u0bcd \u0b8f\u0ba9\u0bcd LBS-\u0b90\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\"><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB)<\/strong><\/a> \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd, \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b8f\u0ba9\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1? \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bc6\u0b9f\u0bcd\u0bb5\u0bca\u0bb0\u0bcd\u0b95\u0bcd \u0b9f\u0bcb\u0baa\u0bbe\u0bb2\u0b9c\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0bb2\u0ba4\u0ba9\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 (CAPEX) \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-ring-topology-argument\">\u0bb5\u0bb3\u0bc8\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbe\u0ba4\u0bae\u0bcd<\/h3>\n\n\n\n<p>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bc0\u0bb3\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bb3\u0bc8\u0baf \u0bae\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd (RMU), \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u201cCCF\u201d \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0ba3\u0bb2\u0bbe\u0bae\u0bcd: \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b95\u0bae\u0bcd\u0baa\u0bbf \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd (\u0b9a\u0bbf-\u0bae\u0bcb\u0b9f\u0bc2\u0bb2\u0bcd):<\/strong> \u0b87\u0bb5\u0bc8 RMU-\u0b90 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf MV \u0bb5\u0bb3\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0bb5\u0bb3\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0bc1\u0bae\u0bcd, \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0ba4\u0bc1\u0ba3\u0bc8\u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b89\u0bb3\u0bcd\u0bb3\u0bc2\u0bb0\u0bcd RMU \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0baf\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8; \u0b85\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd. <em>\u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd<\/em> \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd. <strong>\u0b92\u0bb0\u0bc1 VCB-\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 30%-\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 LBS \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong><\/li>\n\n\n\n<li><strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf (F-\u0bae\u0bcb\u0b9f\u0bc2\u0bb2\u0bcd):<\/strong> \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bc2\u0bb0\u0bcd\u0bb5\u0bbe\u0b9a\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/distribution-transformer-guide\/\"><strong>\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf<\/strong><\/a> (\u0b8e.\u0b95\u0bbe., 500kVA). \u0b87\u0b99\u0bcd\u0b95\u0bc7 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bb5\u0bbf\u0b9f, \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95 LBS-\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b95\u0bb2\u0bb5\u0bc8 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0ba9\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-footprint-advantage\">\u0b95\u0bbe\u0bb2\u0bcd \u0ba4\u0b9f\u0bae\u0bcd \u0ba8\u0ba9\u0bcd\u0bae\u0bc8<\/h3>\n\n\n\n<p>\u0ba8\u0b95\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b87\u0b9f\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0bb5\u0bb3\u0bae\u0bcd. \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 VCB \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd (\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bbf\u0b99\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd) \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b95\u0bcd \u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 SF6 LBS, \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbf\u0ba9\u0bcd \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8 (\u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bbf\u0b9f 2.5 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bcd) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd-\u0b95\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0bb5\u0bbe\u0baf\u0bc1-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb1\u0bcd\u0bb1\u0b9f\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd (\u0b9c\u0bbf\u0b90\u0b8e\u0bb8\u0bcd)<\/strong> \u0ba8\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0ba8\u0b9f\u0bc8\u0baa\u0bbe\u0ba4\u0bc8 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bc8 \u0b9f\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8\u2014\u0baa\u0bbe\u0bb0\u0bae\u0bcd\u0baa\u0bb0\u0bbf\u0baf \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb1\u0bcd\u0bb1\u0b9f\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-operational-mechanics-puffer-vs-rotating-arc\">5. \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd: \u0baa\u0b83\u0baa\u0bb0\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd \u0b9a\u0bc1\u0bb4\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram.webp\" alt=\"SF6 \u0bb5\u0bbe\u0baf\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0baa\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1. \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1, \u0bb5\u0bc6\u0bb3\u0bcd\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bbf. \u0bb5\u0bc6\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bbe\u0ba3\u0bbf \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd. \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: 1. \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1, 2. \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0ba9\u0bbf\u0bae\u0bc8 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf, 3. \u0bae\u0ba3\u0bcd\u0ba3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1. \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0b95\u0bb3\u0bcd: &quot;\u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1&quot;, &quot;\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1&quot;, &quot;\u0bae\u0ba3\u0bcd\u0ba3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd&quot;. \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa, \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bb5\u0b9f\u0bbf\u0bb5, \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0bcb\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2131\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-lbs-three-position-mechanism-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0b85\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc1\u0b95\u0bcb\u0b9f\u0bcd\u0b9f\u0bc8 \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1? \u0b87\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2; \u0b87\u0ba4\u0bc1 \u0b8e\u0bb0\u0bbf\u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b9f\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bbf\u0bb0\u0bb5 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technique-a-puffer-type-the-standard\">\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd A: \u0baa\u0b83\u0baa\u0bb0\u0bcd \u0bb5\u0b95\u0bc8 (\u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8)<\/h3>\n\n\n\n<p>\u0b87\u0ba4\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8 \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b85\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb8\u0bcd\u0b9f\u0ba9\u0bcd, \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b9a\u0bbf\u0bb2\u0bbf\u0ba3\u0bcd\u0b9f\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd SF6 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bc8 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1:<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0b95\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb4\u0bbe\u0baf\u0bcd \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bbf\u0ba9\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bc7 \u0b85\u0b9a\u0bcd\u0b9a\u0bbe\u0b95 \u0bb5\u0bb4\u0bbf\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b87\u0ba9 \u0b85\u0bb4\u0bbf\u0bb5\u0bc1:<\/strong> \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc7\u0b95 \u0bb5\u0bbe\u0baf\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0ba8\u0bc0\u0bb3\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bbf, \u0b85\u0ba4\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8 \u0b85\u0baf\u0ba9\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technique-b-rotating-arc-principle\">\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd B: \u0b9a\u0bc1\u0bb4\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8<\/h3>\n\n\n\n<p>\u0b95\u0ba9\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd (\u0bb7\u0bc6\u0ba9\u0bc0\u0b9f\u0bb0\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd \u0baa\u0bb4\u0bc8\u0baf \u0bb0\u0bc7\u0b9e\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8, \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0baf\u0bc7 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba9\u0bcd:<\/strong> \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0ba9\u0bcd\u0bb1\u0bc1, \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0bb2\u0bbe\u0bb0\u0ba9\u0bcd\u0bb8\u0bcd \u0bb5\u0bbf\u0b9a\u0bc8:<\/strong> \u0b87\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0bae\u0bbe\u0bb5\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 SF6 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bb5\u0b9f\u0bcd\u0b9f\u0bae\u0bbe\u0b95 \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb2\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd:<\/strong> \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u201c\u0b95\u0bb2\u0b95\u0bcd\u0b95\u0bbf\u201d \u0baa\u0bcb\u0bb2 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bc1\u0ba4\u0bbf\u0baf, \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba8\u0b95\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bcb, \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0b85\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba4\u0ba9\u0bcd\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bc7 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0b85\u0bae\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-the-three-position-standard-on-off-earth\">6. \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bcd: \u0b86\u0ba9\u0bcd \u2013 \u0b86\u0b83\u0baa\u0bcd \u2013 \u0b8e\u0bb0\u0bcd\u0ba4\u0bcd<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"2560\" height=\"1396\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-scaled.webp\" alt=\"SF6 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbf\u0bb2\u0bcd \u0baa\u0b83\u0baa\u0bb0\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd.\" class=\"wp-image-2132\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-scaled.webp 2560w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-1024x559.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-1536x838.webp 1536w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-2048x1117.webp 2048w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/sf6-puffer-arc-extinction-process-18x10.webp 18w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n\n\n\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd (IEC 62271-200) \u0ba4\u0bbf\u0bb1\u0bae\u0bcd\u0baa\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9 <strong>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd<\/strong> \u0bb5\u0bbe\u0baf\u0bc1-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb1\u0bcd\u0bb1\u0b9f\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bbf\u0bb2\u0bcd. \u0b87\u0ba4\u0bc1, \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9 \u0b95\u0bc0 \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc6\u0bb0\u0bbf\u0ba4\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4, \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0ba3\u0bcd\u0ba3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bb4\u0bc8\u0baf \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0b95 \u0b85\u0bae\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 \u0b92\u0bb1\u0bcd\u0bb1\u0bc8 \u0b85\u0b9a\u0bcd\u0b9a\u0bbf\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1):<\/strong> \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd (\u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1):<\/strong> \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc2\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd.<\/li>\n\n\n\n<li><strong>\u0baa\u0bc2\u0bae\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f (\u0baa\u0bc2\u0bae\u0bbf):<\/strong> \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0baa\u0bc2\u0bae\u0bbf\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-engineering-advantage\">\u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc7\u0ba9\u0bcd\u0bae\u0bc8<\/h3>\n\n\n\n<p>\u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd, ...-\u0b87\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb5\u0ba4\u0bc8 \u0baa\u0bcc\u0ba4\u0bc0\u0b95 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b87\u0baf\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/strong> \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 <strong>\u0baa\u0bc2\u0bae\u0bbf<\/strong>. \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd <strong>\u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95<\/strong>. \u0b87\u0ba8\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b93\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u201c\u0bae\u0ba9\u0bbf\u0ba4\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u201d \u0b8e\u0ba9\u0bcd\u0bb1 \u0b9a\u0bc2\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bb4\u0bc8\u0baf \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0baa\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0b95\u0bc2\u0bb1\u0bc1:<\/strong> \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0ba3\u0bcd\u0ba3\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd. <a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/earthing-switch\/\"><strong>\u0b89\u0b9f\u0bcd\u0baa\u0bc1\u0bb1 \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0ba3\u0bcd\u0ba3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd (JN15 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd)<\/strong><\/a> \u0b87\u0bb5\u0bc8 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-switch-fuse-coordination-the-striker-mechanism\">7. \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd-\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1: \u201c\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u201d \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism.webp\" alt=\"HRC \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0baa\u0bbf\u0ba9\u0bcd, \u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0ba4\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2133\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/hv-fuse-striker-pin-mechanism-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>LBS-\u0b87\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b9a\u0bc1\u0bb5\u0bbe\u0bb0\u0bb8\u0bcd\u0baf\u0bae\u0bbe\u0ba9 \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bc1, \u0b85\u0ba4\u0bc1 \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1\u0ba4\u0bbe\u0ba9\u0bcd. \u0b87\u0ba4\u0bc1 \u0b86\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 <strong>\u0b90\u0b87\u0b9a\u0bbf 62271-105<\/strong>.<\/p>\n\n\n\n<p>\u201c\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd-\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd,\u201d LBS \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2; \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0bb2\u0bc8\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b9a\u0bc7\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0baa\u0bbf\u0bb4\u0bc8 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/strong> \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b8e\u0bb0\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/strong> \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd HV \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc6\u0bb3\u0bcd\u0bb3\u0bbf\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0bb8\u0bcd\u0b9f\u0bbf\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0baa\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd:<\/strong> \u0b95\u0bc1\u0ba3\u0bcd\u0b9f\u0bc1 \u0bb5\u0bc6\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0bb5\u0bc6\u0b9f\u0bbf\u0bae\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0bb5\u0b9a\u0ba8\u0bcd\u0ba4\u0bae\u0bcd, \u0b92\u0bb0\u0bc1 \u201c\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u201d-\u0b90 \u0b95\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd (\u0b9a\u0bc1\u0bae\u0bbe\u0bb0\u0bcd 60N \u2013 100N) \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba4\u0b9f\u0bc1\u0bae\u0bbe\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf:<\/strong> \u0b87\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd, LBS \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>3-\u0b95\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0bae\u0bcd:<\/strong> \u0b8e\u0bb2\u0bcd.\u0baa\u0bbf.\u0b8e\u0bb8\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 <strong>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd<\/strong> \u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1?<\/strong> \u0b92\u0bb0\u0bc1 \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0bae\u0bc2\u0b9f\u0bbf\u0baf\u0baa\u0b9f\u0bbf\u0baf\u0bc7 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b83\u0baa\u0bc7\u0bb8\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd (\u201c\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb3\u0bcd-\u0b83\u0baa\u0bc7\u0b9a\u0bbf\u0b99\u0bcd\u201d) \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"8-lbs-vs-vcb-a-decision-matrix\">8. LBS vs. VCB: \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0b85\u0ba3\u0bbf\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker-manufacturer\/\"><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd<\/strong><\/a>, VCB \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0ba8\u0bc6\u0b9f\u0bcd\u0bb5\u0bca\u0bb0\u0bcd\u0b95\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bc1\u0baa\u0bb5\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1<\/th><th>SF6 \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd (LBS)<\/th><th>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VCB)<\/th><\/tr><tr><td><strong>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/strong><\/td><td>\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bc7\u0bb2\u0bbe\u0ba3\u0bcd\u0bae\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/td><td>\u0baa\u0bbf\u0bb4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0bae\u0bcd<\/td><\/tr><tr><td><strong>\u0baa\u0bbf\u0bb4\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong><\/td><td><strong>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/strong> (HRC \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<\/td><td><strong>\u0b86\u0bae\u0bcd<\/strong> (40kA+ \u0bb5\u0bb0\u0bc8)<\/td><\/tr><tr><td><strong>\u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/strong><\/td><td>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 (IEC \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 E3, ~100 \u0bae\u0bc1\u0bb4\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1)<\/td><td>\u0b89\u0baf\u0bb0\u0bcd (IEC \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 E2\/C2, ~10,000 \u0bae\u0bc1\u0bb4\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/td><\/tr><tr><td><strong>\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/strong><\/td><td>\u0b8e\u0bb3\u0bbf\u0baf (\u0bb5\u0b9a\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1)<\/td><td>\u0b95\u0bbe\u0bae\u0bcd\u0baa\u0bcd\u0bb3\u0b95\u0bcd\u0bb8\u0bcd (\u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd, CT-\u0b95\u0bb3\u0bcd, \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd)<\/td><\/tr><tr><td><strong>\u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8<\/strong><\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 (\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bb5\u0bbf\u0bb2\u0bc8)<\/td><td>\u0b89\u0baf\u0bb0\u0bcd (3x \u2013 4x \u0baa\u0bb5\u0bc1\u0ba3\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1)<\/td><\/tr><tr><td><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0baa\u0b99\u0bcd\u0b95\u0bc1<\/strong><\/td><td>\u0b86\u0bb0\u0bcd\u0b8e\u0bae\u0bcd\u0baf\u0bc2 \u0bb0\u0bbf\u0b99\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bbf\u0ba9\u0bc8<\/td><td>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b9c\u0bc6\u0ba9\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"9-strategic-applications-environmental-future\">9. \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bbe\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"current-applications\">\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b8e\u0bb0\u0bbf\u0b9a\u0b95\u0bcd\u0ba4\u0bbf klas\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0ba3\u0bcd\u0ba3\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u201c\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b99\u0bcd\u201d \u0b9f\u0bcb\u0baa\u0bbe\u0bb2\u0b9c\u0bbf \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b95\u0bcb\u0baa\u0bc1\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 LBS \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b9a\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b87\u0b9f\u0bc8\u0b9a\u0bcd\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd (CSS):<\/strong> \u0bb5\u0bbe\u0bb4\u0bcd\u0ba8\u0bbe\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc2\u0b9a\u0bbf\u0baf\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0ba8\u0bc1\u0bb4\u0bc8\u0baf \u0bb5\u0bbf\u0b9f\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 SF6 LBS-\u0b90 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bae\u0bc1\u0ba9\u0bcd-\u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bb0\u0bae\u0bbe\u0b95 \u0b86\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> RTU-\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f LBS \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd \u0ba8\u0bca\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbe\u0ba9\u0bbe\u0b95\u0bb5\u0bc7 \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u201c\u0b9a\u0bc1\u0baf-\u0b95\u0bc1\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u201d \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-environmental-challenge-f-gas-regulations\">\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b9a\u0bb5\u0bbe\u0bb2\u0bcd (\u0b8e\u0b83\u0baa\u0bcd-\u0b95\u0bc7\u0bb8\u0bcd \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd)<\/h3>\n\n\n\n<p>SF6 \u0b92\u0bb0\u0bc1 \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 (GWP 23,500). \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0bb5\u0bbf\u0ba4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd (\u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0b92\u0ba9\u0bcd\u0bb1\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd F-\u0b95\u0bc7\u0bb8\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb8\u0bcd\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bbf\u0bb2\u0bcd SF6-\u0b90 \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0ba8\u0bc0\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1 \u0bb5\u0bb2\u0bbf\u0baf\u0bc1\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f LBS:<\/strong> \u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (VCB \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0ba4\u0bc1), \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b87\u0ba4\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bc2\u0baf \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \/ \u0b89\u0bb2\u0bb0\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1:<\/strong> \u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb2\u0bb0\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bb1\u0bcd\u0bb1\u0bc7 \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd:<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95 \u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0bb0\u0bc6\u0b9a\u0bbf\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ol>\n\n\n\n<p>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bbf\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc1 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3 \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd SF6 \u0b86\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"10-engineer-s-faq\">10. \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0ba8\u0bbe\u0ba9\u0bcd SF6 LBS-\u0b90 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bbe?<\/strong> <strong>\u0b95\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8.<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0ba4\u0bbf\u0bb0\u0bcd \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0bae\u0bbe\u0ba9\u0bcb\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb5\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0bae\u0bcd) \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd, \u0b85\u0ba4\u0bc1 \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f SF6 LBS-\u0b90 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bcb\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong> VCB-\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bcb\u0bb2\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 \u0b9a\u0bc0\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0bb3\u0bbf\u0ba4\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1. \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bbe\u0baf\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0bae\u0bc7\u0ba9\u0bcb\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 (\u0b9f\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8):<\/strong> \u0baa\u0bb7\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd &lt; 50\u00b5\u03a9).<\/li>\n\n\n\n<li><strong>\u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd (PD):<\/strong> \u0b9f\u0bbe\u0b99\u0bcd\u0b95\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bc7\u0baf\u0bc7 \u0b89\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf, \u0b95\u0bc8\u0baf\u0b9f\u0b95\u0bcd\u0b95 TEV\/\u0b85\u0bb2\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0b9a\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b95\u0bc73: \u0b92\u0bb0\u0bc1 LBS \u0b92\u0bb0\u0bc1 \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/strong> \u0bae\u0bb1\u0bc1\u0baa\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95, \u0bb8\u0bcd\u0b9f\u0bbe\u0ba3\u0bcd\u0b9f\u0bb0\u0bcd\u0b9f\u0bcd LBS \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd (\u0bb2\u0bc8\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf) \u0b95\u0bc8\u0baf\u0bbe\u0bb3 \u0b9a\u0bbf\u0bb0\u0bae\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd <strong>IEC 62271-103 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 C1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 C2<\/strong> \u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0b89\u0ba4\u0bcd\u0ba4\u0bc7\u0b9a\u0bbf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"11-conclusion-specifying-for-the-right-application\">11. \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8: \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc8<\/h2>\n\n\n\n<p>\u0b85\u0ba8\u0bcd\u0ba4 <strong>SF6 \u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd<\/strong> \u0b87\u0ba4\u0bc1 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0ba4\u0bc1\u0b95\u0bc6\u0bb2\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2, \u0bae\u0bbe\u0bb1\u0bbe\u0b95 \u0b85\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0ba8\u0bc6\u0b9f\u0bcd\u0bb5\u0bca\u0bb0\u0bcd\u0b95\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b9a\u0bca\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95 VCB-\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b93\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95 LBS \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0bb5\u0ba4\u0bc1, \u0bb5\u0bb0\u0bb5\u0bc1\u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0b9f\u0bc8\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bae\u0bb0\u0b9a\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bcb \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<div class=\"xbrele-classic-card\">\n    <div class=\"card-inner\">\n        <div class=\"card-thumb\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/download-icon.webp\" alt=\"SF6 \u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa PDF\">\n        <\/div>\n        \n        <div class=\"card-details\">\n            <span class=\"card-label\">\u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb3\u0bcd\u0bb3\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8<\/span>\n            <h3>SF6 \u0bb2\u0bcb\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd: \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd LBS vs VCB \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/h3>\n            <p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb2\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 SF6 \u0bb5\u0bbe\u0baf\u0bc1 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bb3\u0bc8 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd LBS \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VCB-\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf.<\/p>\n            \n            <div class=\"card-meta\">\n                <span><i class=\"far fa-file-pdf\"><\/i> \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd: PDF \u0b86\u0bb5\u0ba3\u0bae\u0bcd<\/span>\n                <span><i class=\"far fa-user\"><\/i> \u0b86\u0b9a\u0bbf\u0bb0\u0bbf\u0baf\u0bb0\u0bcd: \u0bb9\u0ba9\u0bcd\u0ba9\u0bbe \u0b9c\u0bc1<\/span>\n            <\/div>\n            \n            <a href=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele.com-What-Is-an-SF6-Load-Break-Switch-Working-Principle-LBS-vs-VCB-Guide.pdf\" class=\"card-download-btn\" target=\"_blank\" rel=\"noopener\">\n                <i class=\"fas fa-file-download\"><\/i> SF6 LBS \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\n            <\/a>\n        <\/div>\n    <\/div>\n<\/div>\n\n<style>\n\/* XBRELE \u7ecf\u5178\u5de5\u4e1a\u98ce\u683c - \u54c1\u724c\u8272 #0fb4ad *\/\n.xbrele-classic-card {\n    background: #fdfdfd;\n    border: 1px solid #e1e4e8;\n    border-left: 6px solid #0fb4ad; \/* \u54c1\u724c\u9752\u7eff\u8272\u4fa7\u8fb9\u6761 *\/\n    padding: 28px;\n    margin: 35px 0;\n    border-radius: 4px;\n    box-shadow: 0 2px 12px rgba(0,0,0,0.04);\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n}\n\n.card-inner {\n    display: flex;\n    gap: 30px;\n    align-items: center;\n}\n\n.card-thumb img {\n    width: 130px; \n    height: auto;\n    border-radius: 2px;\n}\n\n.card-label {\n    color: #0fb4ad;\n    font-size: 12px;\n    text-transform: uppercase;\n    font-weight: 800;\n    letter-spacing: 1.2px;\n    margin-bottom: 6px;\n    display: block;\n}\n\n.card-details h3 {\n    margin: 5px 0 10px 0;\n    font-size: 22px;\n    color: #1a1a1a;\n    line-height: 1.3;\n}\n\n.card-details p {\n    font-size: 14.5px;\n    color: #586069;\n    margin-bottom: 18px;\n    line-height: 1.5;\n}\n\n.card-meta {\n    font-size: 13px;\n    color: #959da5;\n    margin-bottom: 22px;\n    display: flex;\n    gap: 20px;\n}\n\n.card-meta i {\n    color: #0fb4ad;\n    margin-right: 5px;\n}\n\n.card-download-btn {\n    display: inline-flex;\n    align-items: center;\n    gap: 10px;\n    background-color: #0fb4ad;\n    color: #ffffff !important;\n    padding: 12px 28px;\n    border-radius: 3px;\n    text-decoration: none !important;\n    font-weight: 700;\n    font-size: 15px;\n    transition: all 0.25s ease;\n    box-shadow: 0 4px 10px rgba(15, 180, 173, 0.2);\n}\n\n.card-download-btn:hover {\n    background-color: #0d9b94;\n    box-shadow: 0 6px 15px rgba(15, 180, 173, 0.3);\n    transform: translateY(-1px);\n}\n\n\/* \u54cd\u5e94\u5f0f\u9002\u914d\u79fb\u52a8\u7aef *\/\n@media (max-width: 650px) {\n    .card-inner { flex-direction: column; text-align: center; }\n    .card-thumb img { width: 100px; }\n    .card-meta { justify-content: center; }\n}\n<\/style>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ta\/products\/\">\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bb2\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/a> ? \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Engineering Key Takeaways \ud83d\udd39 LBS vs. VCB Distinction: An LBS is designed for load management (switching nominal currents), whereas a VCB is a protection device for interrupting massive fault currents. \ud83d\udd39 The 3-Position Safety Logic: Modern RMUs use a mechanically interlocked sequence (ON \u2192 OFF \u2192 EARTH) to physically prevent human errors, such as earthing [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2129,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27,24],"tags":[],"class_list":["post-2126","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2126"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2126\/revisions"}],"predecessor-version":[{"id":3649,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2126\/revisions\/3649"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2129"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2126"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}