{"id":2137,"date":"2025-12-17T14:05:45","date_gmt":"2025-12-17T14:05:45","guid":{"rendered":"https:\/\/xbrele.com\/?p=2137"},"modified":"2026-04-07T14:58:39","modified_gmt":"2026-04-07T14:58:39","slug":"what-is-a-vacuum-interrupter","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/what-is-a-vacuum-interrupter\/","title":{"rendered":"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VI) \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9, \u0b85\u0ba4\u0bc1 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?"},"content":{"rendered":"<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9? (\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf)\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/DjTiW8pCliw?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"background-color: #f5f7f7; border-left: 5px solid #15b3ab; padding: 25px; margin-bottom: 30px; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\">\n    <h2 style=\"color: #333; margin-top: 0; font-size: 1.4rem; font-weight: 700; border-bottom: 1px solid #e0e0e0; padding-bottom: 12px; margin-bottom: 15px;\">\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd: \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8<\/h2>\n    \n    <p style=\"font-size: 1rem; line-height: 1.6; color: #444; margin-bottom: 15px;\">\n        <strong>VCB-\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u201c\u0b87\u0ba4\u0baf\u0bae\u0bcd\u201d:<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VI) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b89\u0bb2\u0b95\u0bb3\u0bb5\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bb0\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf <strong>\u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0b92\u0bb0\u0bc1 \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b85\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (&lt; 10\u207b\u2075 \u0baa\u0bbe) \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0baa\u0bbf\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1.\n    <\/p>\n    \n    <ul style=\"font-size: 1rem; line-height: 1.6; color: #444; margin-bottom: 20px;\">\n        <li style=\"margin-bottom: 8px;\"><strong>\u0bae\u0bc8\u0baf\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd:<\/strong> \u0baa\u0baf\u0ba9\u0bcd\u0b95\u0bb3\u0bcd <strong>\u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1-\u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd<\/strong> \u0b8e\u0bb0\u0bbf\u0ba4\u0bb4\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf \u0bae\u0bc0\u0b9f\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0baa\u0bbe\u0bb7\u0ba9\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf).<\/li>\n        <li style=\"margin-bottom: 8px;\"><strong>\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1:<\/strong> <strong>\u0b8f\u0b8e\u0bae\u0bcd\u0b8e\u0b83\u0baa\u0bcd<\/strong> (\u0b85\u0b9a\u0bcd\u0b9a\u0b95\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2) \u0bb5\u0b9f\u0bbf\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95-\u0bae\u0bbf\u0ba9\u0bcd\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bb1\u0bc8 \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (&gt;40kA) \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0b9a\u0bae\u0baf\u0bae\u0bcd <strong>\u0b86\u0bb0\u0bcd\u0b8e\u0bae\u0bcd\u0b8e\u0b83\u0baa\u0bcd<\/strong> (\u0bb0\u0bc7\u0b9f\u0bbf\u0baf\u0bb2\u0bcd) \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bcd.<\/li>\n        <li style=\"margin-bottom: 8px;\"><strong>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf:<\/strong> \u0bb9\u0bc6\u0bb0\u0bcd\u0bae\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd \u0b9a\u0bc0\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 <strong>\u0b92\u0bb0\u0bc7 \u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong> 20-30 \u0bb5\u0bb0\u0bc1\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bb1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bb2\u0bbe\u0bae\u0bcd).<\/li>\n    <\/ul>\n\n    <div style=\"background-color: rgba(21, 179, 171, 0.08); padding: 12px 15px; border-radius: 2px; border: 1px solid rgba(21, 179, 171, 0.2);\">\n        <p style=\"margin: 0; font-size: 0.95rem; color: #222;\">\n            <strong>\u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1:<\/strong> IEC-\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b86\u0baf\u0bc1\u0bb3\u0bcd (\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 E2\/M2) \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd OEM-\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95, <strong style=\"color: #15b3ab;\">\u0b8e\u0b95\u0bcd\u0bb8\u0bcd.\u0baa\u0bbf.\u0b86\u0bb0\u0bcd.\u0b87.\u0b8e\u0bb2\u0bcd.\u0b87<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd SF6-\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4, \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd 12kV\u201340.5kV \u0b95\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.\n        <\/p>\n    <\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"introduction-the-heart-of-medium-voltage-switching\">\u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0bae\u0bcd: \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bc1\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u201c\u0b87\u0ba4\u0baf\u0bae\u0bcd\u201d<\/h2>\n\n\n\n<p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (MV) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (HV) \u0bae\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1: \u0b85\u0ba4\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd. \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bcb\u0b9f\u0bc1, \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bc2\u0bb3\u0bc8\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd, \u0bae\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bcc\u0ba4\u0bc0\u0b95\u0baa\u0bcd \u0baa\u0ba3\u0bbf, \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbe\u0ba4 \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd \u0b85\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014 <strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (VI)<\/strong>.<\/p>\n\n\n\n<p>\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 ... \u0b87\u0ba9\u0bcd \u201c\u0b87\u0ba4\u0baf\u0bae\u0bcd\u201d \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u201c\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd\u201d \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf<\/a>, VI \u0b92\u0bb0\u0bc1 \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b9a\u0baf\u0bae\u0bcd. \u0b87\u0ba4\u0bc1 630A-\u0b87\u0ba9\u0bcd \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 63 kA-\u0b90\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0b95\u0bcd\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-vacuum-vacuum-vs-sf6-vs-oil\">\u0b8f\u0ba9\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd? (\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd vs. SF6 vs. \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd)<\/h3>\n\n\n\n<p>\u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0baa\u0bbe\u0bb0\u0bae\u0bcd\u0baa\u0bb0\u0bbf\u0baf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bcb\u0bb2\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/sf6-load-break-switch-working-principle\/\">SF6 (\u0b95\u0ba8\u0bcd\u0ba4\u0b95 \u0b86\u0bb1\u0bc6\u0b83\u0baa\u0bcd\u0bb3\u0bc2\u0bb0\u0bc8\u0b9f\u0bc1)<\/a>, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd 12kV\u201340.5kV \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bb0\u0bae\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8:<\/strong> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0bb5\u0bbf\u0ba4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd (\u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0b92\u0ba9\u0bcd\u0bb1\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd F-\u0b95\u0bbe\u0bb8\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) SF6-\u0b90 \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bc7 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1 \u0b92\u0bb0\u0bc7 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u201c\u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0bb1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u201d \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd \u0b8e\u0ba9 \u0b85\u0bb1\u0bbf\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bc0\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f VI, \u0b85\u0ba4\u0ba9\u0bcd 20-30 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<\/li>\n\n\n\n<li><strong>\u0b89\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0bb5\u0bbe\u0baf\u0bc1-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0b9f\u0bcd\u0b9f\u0b9f\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 (30,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8) \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<p>OEM \u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, VIs \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0baf \u0bae\u0bc7\u0bb2\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bbe\u0ba9 \u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd \u0b87\u0ba9\u0bbf \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8. \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd VI \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0bb5\u0bbf\u0bb5\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1: \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bbf\u0baf\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8. \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bb0\u0bc8, \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0ba4\u0bb5, \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0baa\u0bc1\u0ba3\u0bb0\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bbe\u0ba9 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-vacuum-interrupter\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9?<\/h2>\n\n\n\n<p>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/switchgear-component-manufacturer\/\">\u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0bae\u0bcd<\/a> \u0b85\u0ba4\u0bc1 \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 <strong>10\u207b\u2075 \u0baa\u0bbe<\/strong> \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4) \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0b8a\u0b9f\u0b95\u0bae\u0bbe\u0b95.<\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u201c\u0baa\u0bc2\u0bb0\u0ba3\u201d \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0baf\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd, \u0b85\u0ba4\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 SF6-\u0b90 \u0bb5\u0bbf\u0b9f \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8 \u0bb5\u0bbf\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0ba9\u0bc7 <strong>6 \u0bae\u0bbf\u0bae\u0bc0 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 20 \u0bae\u0bbf\u0bae\u0bc0 \u0bb5\u0bb0\u0bc8<\/strong>\u2014\u0b87\u0ba4\u0ba9\u0bcd \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 \u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4\u0bae\u0bbe\u0ba9, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"typical-technical-parameters\">\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0ba4\u0bcb:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1<\/th><th>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \/ \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1<\/th><\/tr><tr><td><strong>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd<\/strong><\/td><td>1.14 kV \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 40.5 kV \u0bb5\u0bb0\u0bc8 (\u0b92\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 72.5 kV \u0bb5\u0bb0\u0bc8)<\/td><\/tr><tr><td><strong>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/strong><\/td><td>630 \u0b8f \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 5000 \u0b8f \u0bb5\u0bb0\u0bc8<\/td><\/tr><tr><td><strong>\u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/strong><\/td><td>16 kA \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 63 kA \u0bb5\u0bb0\u0bc8 (\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95 80 kA \u0bb5\u0bb0\u0bc8)<\/td><\/tr><tr><td><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf<\/strong><\/td><td>6\u0bae\u0bbf\u0bae\u0bc0 (12kV) \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 20\u0bae\u0bbf\u0bae\u0bc0 (40.5kV) \u0bb5\u0bb0\u0bc8<\/td><\/tr><tr><td><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong><\/td><td>10,000 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 M2)<\/td><\/tr><tr><td><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (\u0b95\u0bc1\u0bb1\u0bc1\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1)<\/strong><\/td><td>30 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 100 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 E2)<\/td><\/tr><tr><td><strong>\u0b89\u0bb3\u0bcd\u0bb3\u0b95 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd<\/strong><\/td><td>&lt; 1.33 \u00d7 10\u207b\u00b3 \u0baa\u0bbe (\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bbf\u0bb2\u0bcd)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"the-physics-of-insulation-paschen-s-law\">\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bbf\u0ba9\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd: \u0baa\u0bbe\u0bb7\u0ba9\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf<\/h3>\n\n\n\n<p>\u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3 <em>\u0b8f\u0ba9\u0bcd<\/em> \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb0\u0bcd. <a href=\"https:\/\/en.wikipedia.org\/wiki\/Paschen%27s_law\" target=\"_blank\" rel=\"noopener\"><strong>\u0baa\u0bbe\u0bb7\u0ba9\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf<\/strong><\/a>. \u0b9a\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b89\u0b9f\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bbe\u0b95 \u0bb5\u0bbf\u0bb5\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (<em>p<\/em>) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0ba4\u0bc2\u0bb0\u0bae\u0bcd (<em>d<\/em>).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0baa\u0bcd \u0baa\u0bb2\u0ba9\u0bcd:<\/strong> \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd (\u0baa\u0bbe\u0bb7\u0bc6\u0ba9\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b87\u0b9f\u0ba4\u0bc1 \u0baa\u0b95\u0bcd\u0b95\u0bae\u0bcd), \u0b92\u0bb0\u0bc1 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba8\u0bc0\u0bb3\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bbf\u0ba9\u0bcd \u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd, \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bcb\u0ba4\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b85\u0baf\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0ba9\u0bbf\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0bb5\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<\/li>\n\n\n\n<li><strong>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd \u0ba4reshold:<\/strong> \u0b89\u0bb3\u0bcd\u0bb3\u0b95 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0b87\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8 \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. <strong>10\u207b\u00b2 \u0baa\u0bbe<\/strong>. \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd (\u0b8e.\u0b95\u0bbe., \u0b92\u0bb0\u0bc1 \u0ba8\u0bc1\u0ba3\u0bcd-\u0b95\u0b9a\u0bbf\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95), \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8 \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bc7\u0bb2\u0bc7 \u0ba8\u0b95\u0bb0\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8 \u0b9a\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"internal-structure-anatomy-of-a-vacuum-interrupter\">\u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1: \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0b89\u0b9f\u0bb1\u0bcd\u0b95\u0bc2\u0bb1\u0bc1<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram.webp\" alt=\"\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd, \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bc0\u0bb3\u0bb5\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2141\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram-300x164.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram-768x419.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/vacuum-interrupter-internal-structure-diagram-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b89\u0baf\u0bb0\u0bcd-\u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b86\u0ba9, \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b89\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9 \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-the-contacts-metallurgy-and-manufacturing\">1. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd: \u0b89\u0bb2\u0bcb\u0b95\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf<\/h3>\n\n\n\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0bc2\u0bb1\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b85\u0bb5\u0bc8 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba4\u0bbf\u0bb1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd (\u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1-\u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0b95\u0bb3\u0bcd):<\/strong> \u0ba8\u0bb5\u0bc0\u0ba9 VIs \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 <strong>\u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1-\u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd (CuCr)<\/strong>, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 CuCr50 (50\/50 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bcd). \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bc1 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b89\u0bb0\u0bc1\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u201c\u0b95\u0bc6\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0b99\u0bcd\u201d \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd (\u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0bb5\u0bbe\u0baf\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bc7\u0ba4\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8) \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b9a\u0bbf\u0ba3\u0bcd\u0b9f\u0bb0\u0bbf\u0b99\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd:<\/strong>\n<ul class=\"wp-block-list\">\n<li><em>\u0b9a\u0bbf\u0ba3\u0bcd\u0b9f\u0bb0\u0bbf\u0b99\u0bcd (\u0ba4\u0bbf\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8):<\/em> \u0b92\u0bb0\u0bc1 \u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bbe\u0ba9, \u0b9a\u0bc0\u0bb0\u0bbe\u0ba9 \u0ba8\u0bc1\u0ba3\u0bcd\u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc1 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0ba8\u0bb5\u0bc0\u0ba9 MV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><em>\u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd:<\/em> \u0b89\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bc1, \u0b9a\u0bbf\u0ba3\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1, \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor\/\">\u0b95\u0ba9\u0bb0\u0b95 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/a> \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0bb5\u0bbe\u0baf\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b86\u0b95\u0bcd\u0bb8\u0bbf\u0b9c\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd &lt; 10 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd). \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc0\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd \u0b85\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0bbf, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u201c\u0bae\u0bc6\u0baf\u0bcd\u0ba8\u0bbf\u0b95\u0bb0\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc8\u201d \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-the-metal-bellows-enabling-movement\">2. \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc8\u0baa\u0bcd\u0baa\u0bb1\u0bc8: \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd<\/h3>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b89\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc7 \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc1 \u0bb9\u0bc6\u0bb0\u0bcd\u0bae\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd \u0bae\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc8\u0baf\u0bc8 \u0b89\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3\u0bbf\u0b95\u0bcd\u0b95 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd:<\/strong> \u0bae\u0bbf\u0b95 \u0bae\u0bc6\u0bb2\u0bcd\u0bb2\u0bbf\u0baf (0.1 \u0bae\u0bbf\u0bae\u0bc0 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 0.15 \u0bae\u0bbf\u0bae\u0bc0 \u0bb5\u0bb0\u0bc8) \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0bcb\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc1\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba4 \u0b8e\u0b83\u0b95\u0bc1 (AISI 316L) \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0ba9\u0bcd\u0b95\u0bcb\u0ba9\u0bc6\u0bb2\u0bcd 718.<\/li>\n\n\n\n<li><strong>\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd \u0ba4\u0bbe\u0ba9\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0baa\u0b95\u0bc1\u0ba4\u0bbf. \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd VI-\u0b95\u0bb3\u0bcd 30,000-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 (M2 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1) \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bc8 \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd, \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0b95\u0bcd\u0b95 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-the-insulating-envelope\">3. \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb1\u0bc8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd:<\/strong> \u0b89\u0baf\u0bb0\u0bcd-\u0ba4\u0bb0\u0bae\u0bbe\u0ba9 \u0b85\u0bb2\u0bc1\u0bae\u0bbf\u0ba9\u0bbe<strong>\u0b85\u0bb2\u0bc1\u0bae\u0bbf\u0ba9\u0bbe<\/strong>) \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd (95%+ \u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8). \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0ba4\u0bb2\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bb0\u0bcd \u0b95\u0ba3\u0bcd\u0ba3\u0bbe\u0b9f\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bb0\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b89\u0bb2\u0bcb\u0b95\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd:<\/strong> \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0b9a\u0ba4\u0bbf\u0baf\u0bbe\u0b95, \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bcb\u0bb2\u0bbf\u0baa\u0bcd\u0b9f\u0bbf\u0ba9\u0bae\u0bcd-\u0bae\u0b99\u0bcd\u0b95\u0ba9\u0bc0\u0bb8\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf) \u0b89\u0bb2\u0bcb\u0b95\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4-metal-vapor-shields\">4. \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0baf\u0bc8 \u0b87\u0b9f\u0bc8\u0bae\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1:<\/strong> \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1 \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8, \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0b89\u0b9f\u0bcd\u0baa\u0bc1\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b87\u0ba4\u0bc1 \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd).<\/li>\n\n\n\n<li><strong>\u0bae\u0bbf\u0ba4\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd:<\/strong> \u0b85\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0bc0\u0bb0\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0b95\u0bb5\u0b9a\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. <a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/vacuum-circuit-breaker-parts\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-interrupter-longitudinal-cross-section\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0bc0\u0bb3\u0bb5\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"manufacturing-insight-one-shot-brazing\">\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bb1\u0bbf\u0bb5\u0bc1: \u201c\u0b92\u0bb0\u0bc7-\u0bae\u0bc1\u0bb1\u0bc8\u201d \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n\n\n\n<p>VI-\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1. XBRELE \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bb0 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 <strong>\u201c\u0b92\u0bb0\u0bc7 \u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u201d<\/strong> \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd. \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bb2 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc7 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b89\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b85\u0b9a\u0bcd\u0b9a\u0bc1\u0bb5\u0bb4\u0bbf \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-physics-of-arc-extinction-in-vacuum\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bc2\u0b9f\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0b85\u0baf\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bbe\u0baf\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8. \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b92\u0bb0\u0bc1 <strong>\u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1<\/strong>, \u0b85\u0baf\u0ba9\u0bbf\u0b95\u0bb3\u0bbe\u0bb2\u0bcd (\u0b86\u0bb5\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bc1\/\u0b95\u0bbf\u0bb0\u0bbe\u0bae\u0bcd\u0baa\u0bae\u0bcd) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 <strong>\u0b95\u0bbe\u0ba4\u0bcb\u0b9f\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/strong> (\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bae\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b89\u0bb0\u0bc1\u0b95\u0bbf\u0baf \u0b89\u0bb2\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0b95\u0bc1\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bb3\u0bcd).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-current-zero-and-recovery\">1. \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1<\/h3>\n\n\n\n<p>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd (AC \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf), \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bc1 \u0ba8\u0bbf\u0ba9\u0bcd\u0bb1\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0ba4\u0bcd\u0ba4\u0bcb\u0b9f\u0bc1 \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1 (\u0b9a\u0bc1\u0bae\u0bbe\u0bb0\u0bcd 1000 \u0bae\u0bc0\/\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bb0\u0bb5\u0bbf), \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb0\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1, \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 (TRV) \u0bb5\u0bbf\u0b9f \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-controlling-high-currents-amf-vs-rmf\">2. \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd: AMF vs. RMF<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"920\" height=\"531\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry.webp\" alt=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 AMF (\u0b85\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd RMF (\u0bb5\u0b9f\u0bcd\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bbf\u0bb0\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bb5\u0bbf\u0baf\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1.\" class=\"wp-image-2142\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry.webp 920w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry-300x173.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry-768x443.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/amf-vs-rmf-contact-geometry-18x10.webp 18w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/figure>\n\n\n\n<p>\u0b85\u0ba4\u0bbf\u0b95 \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd (&gt;10kA), \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b9a\u0bca\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b85\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0bb4\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9, \u0ba8\u0bae\u0bcd\u0baa\u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0b85\u0bb3\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bc2\u0b9f\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0ba4\u0bc2\u0ba3\u0bbe\u0b95 \u0b9a\u0bc1\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb0\u0bcd.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"radial-magnetic-field-rmf-the-rotator\">\u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba9\u0bcd (RMF) \u2013 \u201c\u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0bb1\u0bbf\u201d<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <strong>\u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0bb1\u0bc1<\/strong> \u0bb2\u0bcb\u0bb0\u0ba9\u0bcd\u0bb8\u0bcd \u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95.<\/li>\n\n\n\n<li><strong>\u0bb5\u0bbf\u0ba3\u0bcd\u0ba3\u0baa\u0bcd\u0baa\u0bae\u0bcd:<\/strong> \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (31.5kA \u0bb5\u0bb0\u0bc8) \u0b8f\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0b8e\u0bb3\u0bbf\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8, \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"axial-magnetic-field-amf-the-diffuser\">\u0b85\u0b9a\u0bcd\u0b9a \u0b85\u0baf\u0ba9\u0bc1\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb2\u0bae\u0bcd (AMF) \u2013 \u201c\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u201d<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bbe\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <em>\u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0bcd\u0b95\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd<\/em> \u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0ba4\u0bc2\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1. \u0b87\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b95\u0bcd \u0b95\u0bcb\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b86\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. <strong>\u0b9a\u0bbf\u0ba4\u0bb1\u0bb2\u0bcd<\/strong> (\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bc2\u0b9f \u0bae\u0bc1\u0bb4\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bb5\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd).<\/li>\n\n\n\n<li><strong>\u0bb5\u0bbf\u0ba3\u0bcd\u0ba3\u0baa\u0bcd\u0baa\u0bae\u0bcd:<\/strong> \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 (&gt;40kA) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 (&gt;40.5kV) \u0ba4\u0bc7\u0bb5\u0bc8.<\/li>\n\n\n\n<li><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0b95 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b89\u0ba4\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b9c\u0bc6\u0ba9\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0ba9\u0bb0\u0b95 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, <strong>\u0b8f\u0b8e\u0bae\u0bcd\u0b8e\u0b83\u0baa\u0bcd<\/strong> \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b87\u0ba4\u0bc1 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, <strong>\u0b86\u0bb0\u0bcd\u0b8e\u0bae\u0bcd\u0b8e\u0b83\u0baa\u0bcd<\/strong> \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0ba9\u0bae\u0bbe\u0ba9 \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"critical-mechanical-parameters-for-oems\">OEM-\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bbe\u0ba4\u0bc1; \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd OEM \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0bb5\u0bc8:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-contact-pressure-force\">1. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (\u0bb5\u0bbf\u0b9a\u0bc8)<\/h3>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0b85\u0bb5\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u201c\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u201d \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0b9a\u0ba8\u0bcd\u0ba4 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bc7\u0bb5\u0bc8:<\/strong> \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd-\u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 2000N \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 4000N \u0bb5\u0bb0\u0bc8 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-overtravel-contact-wipe\">2. \u0b93\u0bb5\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0bb5\u0bb2\u0bcd (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bbf\u0baa\u0bcd\u0baa\u0bc1)<\/h3>\n\n\n\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0b95\u0bb0 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bb7\u0bcd\u0bb7\u0bc8 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> \u0b87\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8 (\u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8) \u0b88\u0b9f\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b93\u0bb5\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0bb5\u0bb2\u0bcd 3 \u0bae\u0bbf\u0bae\u0bc0 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 4 \u0bae\u0bbf\u0bae\u0bc0 \u0b86\u0b95\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-closing-bounce\">3. \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd<\/h3>\n\n\n\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0bb5\u0bc8 \u0b87\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b95\u0bb5\u0bc7 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1:<\/strong> \u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd \u0b95\u0bbe\u0bb2\u0bae\u0bcd 2ms-\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd, \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bbf, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bae\u0ba8\u0bcd\u0ba4\u0ba8\u0bbf\u0bb2\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"industry-trend-the-move-to-embedded-poles\">\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1: \u0b89\u0b9f\u0bcd\u0baa\u0bca\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc8 \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba8\u0b95\u0bb0\u0bcd\u0bb5\u0bc1<\/h2>\n\n\n\n<p>\u0bb5\u0bb0\u0bb2\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95, VI-\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb0\u0bc1\u0bb3\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd (\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bcd) \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9. \u0ba8\u0bb5\u0bc0\u0ba9 \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1 <a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/\"><strong>\u0ba4\u0bbf\u0b9f \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bae\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong><\/a>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd:<\/strong> \u0bb5\u0bbe\u0b95\u0bcd\u0baf\u0bc2\u0bae\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb0\u0baa\u0bcd\u0b9f\u0bb0\u0bcd, \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9c\u0bc6\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd (APG) \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0bb0\u0bc6\u0b9a\u0bbf\u0ba9\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc6\u0bb0\u0bcd\u0bae\u0bcb\u0baa\u0bbf\u0bb3\u0bbe\u0bb8\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd:<\/strong>\n<ol class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1:<\/strong> VI \u0ba4\u0bc2\u0b9a\u0bbf, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf\u0b95\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8:<\/strong> \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1:<\/strong> VI \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8. \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bbe\u0ba9 XBRELE \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b87\u0ba8\u0bcd\u0ba4 \u0b89\u0b9f\u0bcd\u0baa\u0bca\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ol>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-determines-the-lifetime-of-a-vacuum-interrupter\">\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8e\u0ba4\u0bc1 \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-contact-erosion-electrical-life\">1. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (\u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd)<\/h3>\n\n\n\n<p>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd ~1-3 \u0bae\u0bbf\u0bae\u0bc0 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8 \u0b86\u0bb5\u0bbf \u0b86\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. XBRELE VIs \u0baa\u0bc2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. <strong>\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 E2<\/strong> (IEC 62271-100), \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-vacuum-integrity-shelf-life\">2. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 (\u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bcd)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bcd:<\/strong> 10\u207b\u2077 Pa\u00b7L\/s-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0baa\u0bc6\u0bb1\u0bc1\u0ba8\u0bb0\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b9c\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bcb\u0ba9\u0bbf\u0baf\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0bc6\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, 20-30 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-failure-diagnostics\">3. \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd<\/h3>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 VI \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf \u0b85\u0bb1\u0bbf\u0bb5\u0bc0\u0bb0\u0bcd\u0b95\u0bb3\u0bcd?<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc7 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b92\u0bb0\u0bc1 <strong>\u0bb5\u0bbf\u0b9f\u0bbe\u0bb0\u0bcd (\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>. \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bc1 \u0b92\u0bb3\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0baa\u0bcb\u0baf\u0bcd\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0ba3\u0bbf\u0b95\u0bb2\u0ba9\u0bcd:<\/strong> \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b95\u0bcb\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd:<\/strong> \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 (\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bbe\u0bb2\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions-faqs\">\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd (FAQs)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-life-expectancy-of-a-vacuum-interrupter\">\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9?<\/h3>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bb0 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 <strong>20 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bcd<\/strong>. \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95, \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 VI-\u0b95\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9 <strong>\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 M2 (10,000 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>. \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95, \u0b85\u0bb5\u0bc8 \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8 <strong>\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 E2 (100 \u0bae\u0bc1\u0bb4\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8)<\/strong> \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-you-check-the-vacuum-in-a-circuit-breaker\">\u0b92\u0bb0\u0bc1 \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/h3>\n\n\n\n<p>\u0b95\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc7 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc8 \u0b92\u0bb0\u0bc1 <strong>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbe\u0bb3\u0bb0\u0bcd (\u0bb5\u0bbf\u0b9f\u0bbe\u0bb0\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8)<\/strong>. \u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc7 \u0b85\u0ba4\u0bbf\u0b95 DC \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 AC \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 (\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 75%) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0baf\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bc1\u0bb1\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd; \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-are-the-disadvantages-of-a-vacuum-circuit-breaker\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0baf\u0bbe\u0bb5\u0bc8?<\/h3>\n\n\n\n<p>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bc0\u0bae\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bcd. <strong>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd<\/strong> \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0bb5\u0bc8 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8 (V = L \u00b7 di\/dt) \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd. \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bbe\u0b95, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 <strong>\u0bae\u0bbf\u0b95 \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0ba9\u0bae\u0bbe\u0ba9\u0ba4\u0bc1<\/strong> (72.5 kV \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 145 kV-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd) SF6 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bb2 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-contact-material-is-used-in-vacuum-interrupters\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/h3>\n\n\n\n<p>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd <strong>\u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1-\u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd (CuCr)<\/strong>, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 50\/50 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 75\/25 \u0b8e\u0ba9\u0bcd\u0bb1 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bb2\u0bb5\u0bc8 \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bc1 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b89\u0baf\u0bb0\u0bcd \u0b89\u0bb0\u0bc1\u0b95\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0bb5\u0bbe\u0baf\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bbf \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 \u201c\u0b95\u0bc6\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0b99\u0bcd\u201d \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-are-vacuum-circuit-breakers-preferred-over-sf6\">SF6-\u0b90 \u0bb5\u0bbf\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b8f\u0ba9\u0bcd \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9?<\/h3>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b85\u0bb5\u0bc8 <strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0b95\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1 (\u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd)<\/strong> \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8 <strong>\u0b95\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0b9f\u0bcd\u0b9f \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/strong>. \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b92\u0bb4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0ba4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bbe\u0ba9 SF6-\u0b90\u0baa\u0bcd \u0baa\u0bcb\u0bb2\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1, \u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0b85\u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-internal-pressure-of-a-vacuum-interrupter\">\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9?<\/h3>\n\n\n\n<p>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 <strong>10\u207b\u2075 \u0baa\u0bbe<\/strong>. \u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc7\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bc8 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0ba8\u0bc6\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95, \u0b89\u0bb3\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd ...-\u0b87\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd \u0ba4reshold-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. <strong>10\u207b\u00b2 \u0baa\u0bbe<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-a-vacuum-interrupter-be-repaired-or-refilled\">\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bb5\u0bcb \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/h3>\n\n\n\n<p><strong>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8, \u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1.<\/strong> \u0b87\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0bb8\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd-\u0bae\u0bc1\u0ba4\u0bb2\u0bcd-\u0b89\u0bb2\u0bcb\u0b95\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd, \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbe\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc8 \u0b89\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf \u0b85\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcb, \u0bae\u0bc1\u0bb4\u0bc1 \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb0\u0baa\u0bcd\u0b9f\u0bb0\u0bc8\u0baf\u0bc1\u0bae\u0bcd (\u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0b9f\u0bcd\u0baa\u0bca\u0ba4\u0bbf\u0ba8\u0bcd\u0ba4 \u0baa\u0bcb\u0bb2\u0bc8\u0baf\u0bc1\u0bae\u0bcd) \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion-selecting-for-reliability\">\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8: \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba8\u0bb5\u0bc0\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0b99\u0bcd\u0b95\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0ba9\u0bcd \u0b89\u0bb3\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0baa\u0bbf\u0bb0\u0bc7\u0b9a\u0bbf\u0b99\u0bcd, \u0b89\u0baf\u0bb0\u0bcd-\u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd-\u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1 (CuCr) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 AMF \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd, \u0baa\u0bb2 \u0baa\u0ba4\u0bcd\u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bcb\u0b9f\u0bc1 \u0b87\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b8e\u0b9f\u0bcd <strong>\u0b8e\u0b95\u0bcd\u0bb8\u0bcd.\u0baa\u0bbf.\u0b86\u0bb0\u0bcd.\u0b87.\u0b8e\u0bb2\u0bcd.\u0b87<\/strong>, \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bcb\u0bae\u0bcd. \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd VIs \u0bb5\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 <a href=\"https:\/\/www.google.com\/search?q=https:\/\/webstore.iec.ch\/publication\/62271\" target=\"_blank\" rel=\"noopener\"><strong>\u0b90\u0b87\u0b9a\u0bbf 62271-100<\/strong><\/a> \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd <strong>ANSI\/IEEE C37.60<\/strong> \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd. \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 VCB-\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 OEM \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd \u0b8e\u0ba9 \u0b8e\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0baf\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<div class=\"xbrele-classic-card\">\n    <div class=\"card-inner\">\n        <div class=\"card-thumb\">\n            <img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/download-icon.webp\" alt=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa PDF\">\n        <\/div>\n        \n        <div class=\"card-details\">\n            <span class=\"card-label\">\u0b85\u0ba4\u0bbf\u0b95\u0bbe\u0bb0\u0baa\u0bcd\u0baa\u0bc2\u0bb0\u0bcd\u0bb5 \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/span>\n            <h3>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9? \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/h3>\n            <p>MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bbf\u0ba9\u0bcd \u201c\u0b87\u0ba4\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd\u201d \u0b92\u0bb0\u0bc1 \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf \u0b89\u0baf\u0bb0\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd, \u0baa\u0bc0\u0b99\u0bcd\u0b95\u0bbe\u0ba9\u0bcd-\u0b89\u0bb2\u0bcb\u0b95 \u0baa\u0bbf\u0bb0\u0bc7\u0b9a\u0bbf\u0b99\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd CuCr \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b85\u0bb1\u0bbf\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1.<\/p>\n            \n            <div class=\"card-meta\">\n                <span><i class=\"far fa-file-pdf\"><\/i> \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd: PDF \u0b86\u0bb5\u0ba3\u0bae\u0bcd<\/span>\n                <span><i class=\"far fa-user\"><\/i> \u0b86\u0b9a\u0bbf\u0bb0\u0bbf\u0baf\u0bb0\u0bcd: \u0bb9\u0ba9\u0bcd\u0ba9\u0bbe \u0b9c\u0bc1<\/span>\n            <\/div>\n            \n            <a href=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/xbrele.com-What-Is-a-Vacuum-Interrupter.pdf\" class=\"card-download-btn\" target=\"_blank\" rel=\"noopener\">\n                <i class=\"fas fa-file-download\"><\/i> VI \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\n            <\/a>\n        <\/div>\n    <\/div>\n<\/div>\n\n<style>\n\/* XBRELE \u7ecf\u5178\u5de5\u4e1a\u98ce\u683c - \u54c1\u724c\u8272 #0fb4ad *\/\n.xbrele-classic-card {\n    background: #fdfdfd;\n    border: 1px solid #e1e4e8;\n    border-left: 6px solid #0fb4ad; \/* \u54c1\u724c\u9752\u7eff\u8272\u4fa7\u8fb9\u6761 *\/\n    padding: 28px;\n    margin: 35px 0;\n    border-radius: 4px;\n    box-shadow: 0 2px 12px rgba(0,0,0,0.04);\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n}\n\n.card-inner {\n    display: flex;\n    gap: 30px;\n    align-items: center;\n}\n\n.card-thumb img {\n    width: 130px; \n    height: auto;\n    border-radius: 2px;\n}\n\n.card-label {\n    color: #0fb4ad;\n    font-size: 12px;\n    text-transform: uppercase;\n    font-weight: 800;\n    letter-spacing: 1.2px;\n    margin-bottom: 6px;\n    display: block;\n}\n\n.card-details h3 {\n    margin: 5px 0 10px 0;\n    font-size: 22px;\n    color: #1a1a1a;\n    line-height: 1.3;\n}\n\n.card-details p {\n    font-size: 14.5px;\n    color: #586069;\n    margin-bottom: 18px;\n    line-height: 1.5;\n}\n\n.card-meta {\n    font-size: 13px;\n    color: #959da5;\n    margin-bottom: 22px;\n    display: flex;\n    gap: 20px;\n}\n\n.card-meta i {\n    color: #0fb4ad;\n    margin-right: 5px;\n}\n\n.card-download-btn {\n    display: inline-flex;\n    align-items: center;\n    gap: 10px;\n    background-color: #0fb4ad;\n    color: #ffffff !important;\n    padding: 12px 28px;\n    border-radius: 3px;\n    text-decoration: none !important;\n    font-weight: 700;\n    font-size: 15px;\n    transition: all 0.25s ease;\n    box-shadow: 0 4px 10px rgba(15, 180, 173, 0.2);\n}\n\n.card-download-btn:hover {\n    background-color: #0d9b94;\n    box-shadow: 0 6px 15px rgba(15, 180, 173, 0.3);\n    transform: translateY(-1px);\n}\n\n\/* \u54cd\u5e94\u5f0f\u9002\u914d\u79fb\u52a8\u7aef *\/\n@media (max-width: 650px) {\n    .card-inner { flex-direction: column; text-align: center; }\n    .card-thumb img { width: 100px; }\n    .card-meta { justify-content: center; }\n}\n<\/style>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ta\/products\/\">\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bb2\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/a> ? \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Executive Summary: Engineering Quick View The &#8220;Heart&#8221; of VCBs: The Vacuum Interrupter (VI) is the globally accepted standard for medium-voltage switching, utilizing Metal Vapor Arc Extinction in a high-vacuum chamber (< 10\u207b\u2075 Pa) to interrupt massive fault currents. Core Technology: Uses CuCr (Copper-Chromium) contacts to prevent welding and ensure rapid dielectric recovery (Paschen\u2019s Law). Arc [&hellip;]\n<\/p>\n","protected":false},"author":3,"featured_media":2140,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27,24],"tags":[],"class_list":["post-2137","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2137","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2137"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2137\/revisions"}],"predecessor-version":[{"id":3634,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2137\/revisions\/3634"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2140"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2137"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2137"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2137"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}